  1. A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

    Energy Technology Data Exchange (ETDEWEB)

    Aldosari, A. H.; Petasecca, M., E-mail: marcop@uow.edu.au; Espinoza, A.; Newall, M.; Fuduli, I.; Porumb, C.; Alshaikh, S.; Alrowaili, Z. A.; Weaver, M.; Metcalfe, P.; Lerch, M. L. F.; Rosenfeld, A. B. [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2500 (Australia); Carolan, M. [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2500, Australia and Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, NSW 2500 (Australia); Perevertaylo, V. [SPA-BIT, KIEV 02232 (Ukraine)

    2014-09-15

    Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP

  2. Dosimetric characterization of a commercial two-dimensional array detector; Caracterizacao dosimetrica de um detector matricial bidimensional comercial

    Energy Technology Data Exchange (ETDEWEB)

    Gialluisi, Bruno L.; Santos, Gabriela R. dos; Sales, Camila P. de; Resende, Guilherme R.A.; Habitzreuter, Angela B.; Rodrigues, Laura N., E-mail: brunogialluisi@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2013-04-15

    This paper investigates the dosimetric characteristics and performance of an array detector commercially available. The device is the I'mRT MatriXX® which is a two-dimensional detector array used in the verification of complex radiotherapy plans. It consists of 1,020 parallel plate ion chamber arranged in a 32x32 grid. Dose linearity was studied and its response was linear within the range of 5 to 1000 MU (R{sup 2} = 1). Dose rate dependence showed a maximum deviation of 0,62% comparatively with readings to 320 cGy/min. The detector stability was verified through repeated irradiations. Output factors matched well with measurements made with a Farmer chamber with an average deviation of 1,54%. The detector's effective point of measurement was determined and the inverse square law was also verified with a percentage deviation smaller than 3%. The results show that this detector can be used for quality control in IMRT thus reducing the time spent in the dosimetric verification of radiation fields. (author)

  3. Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Liengsawangwong, Praimakorn; Sahoo, Nanayan; Ding, Xiaoning; Lii, MingFwu; Gillin, Michale T.; Zhu, Xiaorong Ronald, E-mail: xrzhu@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030 (United States)

    2015-07-30

    Purpose: To evaluate the dosimetric characteristics of a two-dimensional (2D) diode array detector irradiated with passively scattered proton beams. Materials and Methods: A diode array detector, MapCHECK (Model 1175, Sun Nuclear, Melbourne, FL, USA) was characterized in passive-scattered proton beams. The relative sensitivity of the diodes and absolute dose calibration were determined using a 250 MeV beam. The pristine Bragg curves (PBCs) measured by MapCHECK diodes were compared with those of an ion chamber using a range shift method. The water-equivalent thickness (WET) of the diode array detector’s intrinsic buildup also was determined. The inverse square dependence, linearity, and other proton dosimetric quantities measured by MapCHECK were also compared with those of the ion chambers. The change in the absolute dose response of the MapCHECK as a function of accumulated radiation dose was used as an indicator of radiation damage to the diodes. 2D dose distribution with and without the compensator were measured and compared with the treatment planning system (TPS) calculations. Results: The WET of the MapCHECK diode’s buildup was determined to be 1.7 cm. The MapCHECK-measured PBC were virtually identical to those measured by a parallel-plate ion chamber for 160, 180, and 250 MeV proton beams. The inverse square results of the MapCHECK were within ±0.4% of the ion chamber results. The linearity of MapCHECK results was within 1% of those from the ion chamber as measured in the range between 10 and 300 MU. All other dosimetric quantities were within 1.3% of the ion chamber results. The 2D dose distributions for non-clinical fields without compensator and the patient treatment fields with the compensator were consistent with the TPS results. The absolute dose response of the MapCHECK was changed by 7.4% after an accumulated dose increased by 170 Gy. Conclusions: The MapCHECK is a convenient and useful tool for 2D dose distribution measurements using passively

  4. Two dimensional extensible array configuration for EMCCD-based solid state x-ray detectors.

    Science.gov (United States)

    Sharma, P; Vasan, S N Swetadri; Cartwright, A N; Titus, A H; Bednarek, D R; Rudin, S

    2012-01-01

    We have designed and developed from the discrete component level a high resolution dynamic x- ray detector to be used for fluoroscopic and angiographic medical imaging. The heart of the detector is a 1024 × 1024 pixel electron multiplying charge coupled device (EMCCD) with a pixel size of 13 × 13 μm(2) (Model CCD201-20, e2v Technologies, Inc.), bonded to a fiber optic plate (FOP), and optically coupled to a 350 μm thick micro-columnar CsI(TI) scintillator via a fiber optic taper (FOT). Our aim is to design an array of these detectors that could be extended to any arbitrary X × Y size in two dimensions to provide a larger field of view (FOV). A physical configuration for a 3×3 array is presented that includes two major sub-systems. First is an optical front end that includes (i) a phosphor to convert the x-ray photons into light photons, and (ii) a fused array of FOTs that focuses light photons from the phosphor onto an array of EMCCD's optically coupled using FOPs. Second is an electronic front end that includes (i) an FPGA board used for generating clocks and for data acquisition (ii) driver boards to drive and digitize the analog output from the EMCCDs, (iii) a power board, and (iv) headboards to hold the EMCCD's while they are connected to their respective driver board using flex cables. This configuration provides a larger FOV as well as region-of- interest (ROI) high-resolution imaging as required by modern neurovascular procedures.

  5. Two dimensional extensible array configuration for EMCCD-based solid state x-ray detectors

    Science.gov (United States)

    Sharma, P.; Swetadri Vasan, S. N.; Cartwright, A. N.; Titus, A. H.; Bednarek, D. R.; Rudin, S.

    2012-03-01

    We have designed and developed from the discrete component level a high resolution dynamic x-ray detector to be used for fluoroscopic and angiographic medical imaging. The heart of the detector is a 1024 ×1024 pixel electron multiplying charge coupled device (EMCCD) with a pixel size of 13 × 13 μm2 (Model CCD201-20, e2v Technologies, Inc.), bonded to a fiber optic plate (FOP), and optically coupled to a 350 μm thick micro-columnar CsI(TI) scintillator via a fiber optic taper (FOT). Our aim is to design an array of these detectors that could be extended to any arbitrary X × Y size in two dimensions to provide a larger field of view (FOV). A physical configuration for a 3×3 array is presented that includes two major sub-systems. First is an optical front end that includes (i) a phosphor to convert the x-ray photons into light photons, and (ii) a fused array of FOTs that focuses light photons from the phosphor onto an array of EMCCD's optically coupled using FOPs. Second is an electronic front end that includes (i) an FPGA board used for generating clocks and for data acquisition (ii) driver boards to drive and digitize the analog output from the EMCCDs, (iii) a power board, and (iv) headboards to hold the EMCCD's while they are connected to their respective driver board using flex cables. This configuration provides a larger FOV as well as region-of-interest (ROI) high-resolution imaging as required by modern neurovascular procedures.

  6. Two-dimensional microstrip detector for neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Oed, A. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    Because of their robust design, gas microstrip detectors, which were developed at ILL, can be assembled relatively quickly, provided the prefabricated components are available. At the beginning of 1996, orders were received for the construction of three two-dimensional neutron detectors. These detectors have been completed. The detectors are outlined below. (author). 2 refs.

  7. Kronecker Product of Two-dimensional Arrays

    Institute of Scientific and Technical Information of China (English)

    Lei Hu

    2006-01-01

    Kronecker sequences constructed from short sequences are good sequences for spread spectrum communication systems. In this paper we study a similar problem for two-dimensional arrays, and we determine the linear complexity of the Kronecker product of two arrays. Our result shows that similar good property on linear complexity holds for Kronecker product of arrays.

  8. A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files

    Science.gov (United States)

    Santiago, Juan Agustin Calama; Utrilla, Miguel Angel Infante; Rodriguez, Maria Elisa Lavado

    2015-01-01

    This paper proposes a method for improving the resolution of the fluence derived from detector array measurement using the information collected in dynalog files. From dynalog information, a file is generated with the actual multileaf collimator (MLC) positions and used as input to the treatment planning system (TPS) to obtain the dynalog-derived fluence and the theoretical response over the detector array. In contrast with the measured response, this theoretical response allows for correction of the dynalog-derived fluence and translation into the reconstructed fluence. This fluence is again introduced into the planning system to verify the treatment using clinical tools. Initially, more than 98% of the points passed the two-dimensional (2D) phantom gamma test (3% local dose - 3 mm) for all of the treatment verifications, but in some dose–volume histogram (DVH) comparisons, we note sensitive differences for the planning target volume (PTV) coverage and for the maximum doses in at-risk organs (up to 3.5%). In dose–distribution evaluations, we found differences of up to 5% in the PTV edges in certain cases due to detector array measurement errors. This work improves the resolution of the fluence derived from detector array measurements based on the treatment information, in contrast with the current commercial proposals based on planned data. PMID:26150681

  9. A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files

    Directory of Open Access Journals (Sweden)

    Juan Agustin Calama Santiago

    2015-01-01

    Full Text Available This paper proposes a method for improving the resolution of the fluence derived from detector array measurement using the information collected in dynalog files. From dynalog information, a file is generated with the actual multileaf collimator (MLC positions and used as input to the treatment planning system (TPS to obtain the dynalog-derived fluence and the theoretical response over the detector array. In contrast with the measured response, this theoretical response allows for correction of the dynalog-derived fluence and translation into the reconstructed fluence. This fluence is again introduced into the planning system to verify the treatment using clinical tools. Initially, more than 98% of the points passed the two-dimensional (2D phantom gamma test (3% local dose - 3 mm for all of the treatment verifications, but in some dose-volume histogram (DVH comparisons, we note sensitive differences for the planning target volume (PTV coverage and for the maximum doses in at-risk organs (up to 3.5%. In dose-distribution evaluations, we found differences of up to 5% in the PTV edges in certain cases due to detector array measurement errors. This work improves the resolution of the fluence derived from detector array measurements based on the treatment information, in contrast with the current commercial proposals based on planned data.

  10. Two-dimensional position sensitive neutron detector

    Indian Academy of Sciences (India)

    A M Shaikh; S S Desai; A K Patra

    2004-08-01

    A two-dimensional position sensitive neutron detector has been developed. The detector is a 3He + Kr filled multiwire proportional counter with charge division position readout and has a sensitive area of 345 mm × 345 mm, pixel size 5 mm × 5 mm, active depth 25 mm and is designed for efficiency of 70% for 4 Å neutrons. The detector is tested with 0.5 bar 3He + 1.5 bar krypton gas mixture in active chamber and 2 bar 4He in compensating chamber. The pulse height spectrum recorded at an anode potential of 2000 V shows energy resolution of ∼ 25% for the 764 keV peak. A spatial resolution of 8 mm × 6 mm is achieved. The detector is suitable for SANS studies in the range of 0.02–0.25 Å-1.

  11. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    Science.gov (United States)

    Markovic, Miljenko; Stathakis, Sotirios; Mavroidis, Panayiotis; Jurkovic, Ines-Ana; Papanikolaou, Nikos

    2014-05-01

    The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm(3)) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm(2) both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5-85 Gy and 0.5-10 Gy min(-1), respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm(2). For field sizes down to 1 × 1 cm(2), the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and

  12. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, Miljenko, E-mail: markovic@livemail.uthscsa.edu; Stathakis, Sotirios; Mavroidis, Panayiotis; Jurkovic, Ines-Ana; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, Texas 78229 (United States)

    2014-05-15

    Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled

  13. Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

    Science.gov (United States)

    Allen, Robert C; Rutan, Sarah C

    2011-10-31

    Simulated and experimental data were used to measure the effectiveness of common interpolation techniques during chromatographic alignment of comprehensive two-dimensional liquid chromatography-diode array detector (LC×LC-DAD) data. Interpolation was used to generate a sufficient number of data points in the sampled first chromatographic dimension to allow for alignment of retention times from different injections. Five different interpolation methods, linear interpolation followed by cross correlation, piecewise cubic Hermite interpolating polynomial, cubic spline, Fourier zero-filling, and Gaussian fitting, were investigated. The fully aligned chromatograms, in both the first and second chromatographic dimensions, were analyzed by parallel factor analysis to determine the relative area for each peak in each injection. A calibration curve was generated for the simulated data set. The standard error of prediction and percent relative standard deviation were calculated for the simulated peak for each technique. The Gaussian fitting interpolation technique resulted in the lowest standard error of prediction and average relative standard deviation for the simulated data. However, upon applying the interpolation techniques to the experimental data, most of the interpolation methods were not found to produce statistically different relative peak areas from each other. While most of the techniques were not statistically different, the performance was improved relative to the PARAFAC results obtained when analyzing the unaligned data.

  14. A Vacuum Ultraviolet Absorption Array Spectrometer as a Selective Detector for Comprehensive Two-Dimensional Gas Chromatography: Concept and First Results.

    Science.gov (United States)

    Gröger, Thomas; Gruber, Beate; Harrison, Dale; Saraji-Bozorgzad, Mohammad; Mthembu, Makhosazana; Sutherland, Aimée; Zimmermann, Ralf

    2016-03-15

    Fast and selective detectors are very interesting for comprehensive two-dimensional gas chromatography (GC × GC). This is particularly true if the detector system can provide additional spectroscopic information on the compound structure and/or functionality. Other than mass spectrometry (MS), only optical spectroscopic detectors are able to provide selective spectral information. However, until present the application of optical spectroscopy technologies as universal detectors for GC × GC has been restricted mainly due to physical limitations such as insufficient acquisition speed or high detection limits. A recently developed simultaneous-detection spectrometer working in the vacuum ultraviolet (VUV) region of 125-240 nm overcomes these limitations and meets all the criteria of a universal detector for GC × GC. Peak shape and chromatographic resolution is preserved and unique spectral information, complementary to mass spectrometry data, is gained. The power of this detector is quickly recognized as it has the ability to discriminate between isomeric compounds or difficult to separate structurally related isobaric species; thus, it provides additional selectivity. A further promising feature of this detector is the data analysis concept of spectral filtering, which is accomplished by targeting special electronic transitions that allows for a fast screening of GC × GC chromatograms for designated compound classes.

  15. Defect Characterization Using Two-Dimensional Arrays

    Science.gov (United States)

    Velichko, A.; Wilcox, P. D.

    2011-06-01

    2D arrays are able to `view' a given defect from a range of angles leading to the possibility of obtaining richer characterization detail than possible with 1D arrays. In this paper a quantitative comparison of 2D arrays with different element layouts is performed. A technique for extracting the scattering matrix of a defect from the raw 2D array data is also presented. The method is tested on experimental data for characterization of various volumetric defects.

  16. Two-dimensional supramolecular electron spin arrays.

    Science.gov (United States)

    Wäckerlin, Christian; Nowakowski, Jan; Liu, Shi-Xia; Jaggi, Michael; Siewert, Dorota; Girovsky, Jan; Shchyrba, Aneliia; Hählen, Tatjana; Kleibert, Armin; Oppeneer, Peter M; Nolting, Frithjof; Decurtins, Silvio; Jung, Thomas A; Ballav, Nirmalya

    2013-05-07

    A bottom-up approach is introduced to fabricate two-dimensional self-assembled layers of molecular spin-systems containing Mn and Fe ions arranged in a chessboard lattice. We demonstrate that the Mn and Fe spin states can be reversibly operated by their selective response to coordination/decoordination of volatile ligands like ammonia (NH3). Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Tilted Two-Dimensional Array Multifocus Confocal Raman Microspectroscopy.

    Science.gov (United States)

    Yabumoto, Sohshi; Hamaguchi, Hiro-O

    2017-07-18

    A simple and efficient two-dimensional multifocus confocal Raman microspectroscopy featuring the tilted-array technique is demonstrated. Raman scattering from a 4 × 4 square foci array passing through a 4 × 4 confocal pinhole array is tilted with a periscope. The tilted array of Raman scattering signals is dispersed by an imaging spectrograph onto a CCD detector, giving 16 independent Raman spectra formed as 16 bands with different heights on the sensor. Use of a state-of-the-art imaging spectrograph enables high-precision wavenumber duplicability of the 16 spectra. This high duplicability makes the simultaneously obtained spectra endurable for multivariate spectral analyses, which is demonstrated by a singular value decomposition analysis for Raman spectra of liquid indene. Although the present implementation attains only 16 measurement points, the number of points can be extended to larger than 100 without any technical leaps. Limit of parallelization depends on the interval of measurement points as well as the performance of the optical system. Criteria for finding the maximum feasible number are discussed.

  18. THE DEGENERACY PROBLEM OF TWO-DIMENSIONAL LINEAR RECURRING ARRAYS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The degeneracy degree and degeneracy position sets of a wo-dimensional linear recurrence relation set are characterized. The fact that a linear recurring array is essentially a doubly periodic array is shown. By using the Grbner base theory, a calculation formula for degeneracy degree is given and the existence of a special degeneracy position set is proved. In the present paper, the degeneracy problem of the two-dimensional linear recurring arrays is completely solved.

  19. Two-dimensional random arrays for real time volumetric imaging

    DEFF Research Database (Denmark)

    Davidsen, Richard E.; Jensen, Jørgen Arendt; Smith, Stephen W.

    1994-01-01

    Two-dimensional arrays are necessary for a variety of ultrasonic imaging techniques, including elevation focusing, 2-D phase aberration correction, and real time volumetric imaging. In order to reduce system cost and complexity, sparse 2-D arrays have been considered with element geometries...... real time volumetric imaging system, which employs a wide transmit beam and receive mode parallel processing to increase image frame rate. Depth-of-field comparisons were made from simulated on-axis and off-axis beamplots at ranges from 30 to 160 mm for both coaxial and offset transmit and receive...... selected ad hoc, by algorithm, or by random process. Two random sparse array geometries and a sparse array with a Mills cross receive pattern were simulated and compared to a fully sampled aperture with the same overall dimensions. The sparse arrays were designed to the constraints of the Duke University...

  20. Two-dimensional pixel array image sensor for protein crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Beuville, E.; Beche, J.-F.; Cork, C. [and others

    1996-07-01

    A 2D pixel array image sensor module has been designed for time resolved Protein Crystallography. This smart pixels detector significantly enhances time resolved Laue Protein crystallography by two to three orders of magnitude compared to existing sensors like films or phosphor screens coupled to CCDs. The resolution in time and dynamic range of this type of detector will allow one to study the evolution of structural changes that occur within the protein as a function of time. This detector will also considerably accelerate data collection in static Laue or monochromatic crystallography and make better use of the intense beam delivered by synchrotron light sources. The event driven pixel array detectors, based on the column Architecture, can provide multiparameter information (energy discrimination, time), with sparse and frameless readout without significant dead time. The prototype module consists of a 16x16 pixel diode array bump-bonded to the integrated circuit. The detection area is 150x150 square microns.

  1. SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Chacko, M; Aldoohan, S; Sonnad, J; Ahmad, S; Ali, I [University of Oklahoma Health Science Center, Oklahoma City, OK (United States)

    2015-06-15

    Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: The dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.

  2. SCAPS, a two-dimensional ion detector for mass spectrometer

    Science.gov (United States)

    Yurimoto, Hisayoshi

    2014-05-01

    Faraday Cup (FC) and electron multiplier (EM) are of the most popular ion detector for mass spectrometer. FC is used for high-count-rate ion measurements and EM can detect from single ion. However, FC is difficult to detect lower intensities less than kilo-cps, and EM loses ion counts higher than Mega-cps. Thus, FC and EM are used complementary each other, but they both belong to zero-dimensional detector. On the other hand, micro channel plate (MCP) is a popular ion signal amplifier with two-dimensional capability, but additional detection system must be attached to detect the amplified signals. Two-dimensional readout for the MCP signals, however, have not achieve the level of FC and EM systems. A stacked CMOS active pixel sensor (SCAPS) has been developed to detect two-dimensional ion variations for a spatial area using semiconductor technology [1-8]. The SCAPS is an integrated type multi-detector, which is different from EM and FC, and is composed of more than 500×500 pixels (micro-detectors) for imaging of cm-area with a pixel of less than 20 µm in square. The SCAPS can be detected from single ion to 100 kilo-count ions per one pixel. Thus, SCAPS can be accumulated up to several giga-count ions for total pixels, i.e. for total imaging area. The SCAPS has been applied to stigmatic ion optics of secondary ion mass spectrometer, as a detector of isotope microscope [9]. The isotope microscope has capabilities of quantitative isotope images of hundred-micrometer area on a sample with sub-micrometer resolution and permil precision, and of two-dimensional mass spectrum on cm-scale of mass dispersion plane of a sector magnet with ten-micrometer resolution. The performance has been applied to two-dimensional isotope spatial distribution for mainly hydrogen, carbon, nitrogen and oxygen of natural (extra-terrestrial and terrestrial) samples and samples simulated natural processes [e.g. 10-17]. References: [1] Matsumoto, K., et al. (1993) IEEE Trans. Electron Dev. 40

  3. Topological Quantum Optics in Two-Dimensional Atomic Arrays

    Science.gov (United States)

    Perczel, J.; Borregaard, J.; Chang, D. E.; Pichler, H.; Yelin, S. F.; Zoller, P.; Lukin, M. D.

    2017-07-01

    We demonstrate that two-dimensional atomic emitter arrays with subwavelength spacing constitute topologically protected quantum optical systems where the photon propagation is robust against large imperfections while losses associated with free space emission are strongly suppressed. Breaking time-reversal symmetry with a magnetic field results in gapped photonic bands with nontrivial Chern numbers and topologically protected, long-lived edge states. Due to the inherent nonlinearity of constituent emitters, such systems provide a platform for exploring quantum optical analogs of interacting topological systems.

  4. Soliton nanoantennas in two-dimensional arrays of quantum dots

    CERN Document Server

    Gligorić, G; Hadžievski, Lj; Slepyan, G Ya; Malomed, B A

    2015-01-01

    We consider two-dimensional (2D) arrays of self-organized semiconductor quantum dots (QDs) strongly interacting with electromagnetic field in the regime of Rabi oscillations. The QD array built of two-level states is modelled by two coupled systems of discrete nonlinear Schr\\"{o}dinger equations. Localized modes in the form of single-peaked fundamental and vortical stationary Rabi solitons and self-trapped breathers have been found. The results for the stability, mobility and radiative properties of the Rabi modes suggest a concept of a self-assembled 2D \\textit{% soliton-based nano-antenna}, which should be stable against imperfections In particular, we discuss the implementation of such a nano-antenna in the form of surface plasmon solitons in graphene, and illustrate possibilities to control their operation by means of optical tools.

  5. Design and Fabrication of a Two-Dimensional Superconducting Pop-up Bolometer Array

    Science.gov (United States)

    Benford, Dominic J.; Staguhn, Johannes G.; Chervenak, James A.; Allen, Christine A.; Moseley, S. Harvey; Irwin, Kent D.; Stacey, Gordon J.; Page, Lyman A.

    2004-01-01

    We have been developing an architecture for producing large format, two dimensional arrays of close-packed bolometers, which will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The low backgrounds achieved in these instruments require very sensitive detectors with NEPs of order 5 x 10(exp -18) W/square root of Hz. Superconducting transition edge sensor bolometers can be close-packed using the Pop-up Detector (PUD) format, and SQUID multiplexers operating at the detector base temperature can be intimately coupled to them. The array unit cell is 8 x 32 pixels, using 32- element detector and multiplexer components. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays. We report on the production of the 32-element components for the arrays. Planned instruments using this array architecture include the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory, the South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory, the Millimeter Bolometer Camera for the Atacama Cosmology Telescope (MBC/ACT), and the Redshift (Z) Early Universe Spectrometer (ZEUS j.

  6. Detector-Response Correction of Two-Dimensional γ-Ray Spectra from Neutron Capture

    Directory of Open Access Journals (Sweden)

    Rusev G.

    2015-01-01

    Full Text Available The neutron-capture reaction produces a large variety of γ-ray cascades with different γ-ray multiplicities. A measured spectral distribution of these cascades for each γ-ray multiplicity is of importance to applications and studies of γ-ray statistical properties. The DANCE array, a 4π ball of 160 BaF2 detectors, is an ideal tool for measurement of neutron-capture γ-rays. The high granularity of DANCE enables measurements of high-multiplicity γ-ray cascades. The measured two-dimensional spectra (γ-ray energy, γ-ray multiplicity have to be corrected for the DANCE detector response in order to compare them with predictions of the statistical model or use them in applications. The detector-response correction problem becomes more difficult for a 4π detection system than for a single detector. A trial and error approach and an iterative decomposition of γ-ray multiplets, have been successfully applied to the detector-response correction. Applications of the decomposition methods are discussed for two-dimensional γ-ray spectra measured at DANCE from γ-ray sources and from the 10B(n, γ and 113Cd(n, γ reactions.

  7. Two-dimensional photon counting imaging detector based on a Vernier position sensitive anode readout

    Institute of Scientific and Technical Information of China (English)

    鄢秋荣; 赵宝升; 刘永安; 杨颢; 盛立志; 韦永林

    2011-01-01

    A two-dimensional photon counting imaging detector based on a Vernier position sensitive anode is reported. The decode principle and design of a two-dimensional Vernier anode are introduced in detail. A photon counting imaging system was built based on a

  8. Strategies for Ultrasound Imaging Using Two-Dimensional Arrays

    Science.gov (United States)

    Velichko, A.; Wilcox, P. D.

    2010-02-01

    2D arrays are able to `view' a given defect from a range of angles leading to the possibility of obtaining richer characterization detail than possible with 1D arrays. This has clear benefits as real defects and engineering structures are three-dimensional. This paper describes different approaches to optimize 2D array design. Results are shown that illustrate the application of the proposed techniques to modeling and experimental data.

  9. Plasmon spectra in two-dimensional nanorod arrays

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Z H; Fava, D; Kumacheva, E [Department of Chemistry, University of Toronto, Toronto, Ontario, M5S 3H6 (Canada); Ruda, H E; Shik, A [Centre for Advanced Nanotechnology, University of Toronto, Toronto, Ontario, M5S 3E4 (Canada)

    2009-07-22

    For various types of ensembles of metal nanorods, the frequencies of longitudinal and transverse plasmons were calculated and correlations between the plasmon frequency shifts and the topology of nanorod arrays were found. The theoretical predictions were compared with the experimentally determined optical absorption in arrays of polymer-terminated Au nanorods obtained by self-assembly in selective solvents.

  10. Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance.

    Science.gov (United States)

    Arjomandy, Bijan; Sahoo, Narayan; Ding, Xiaoning; Gillin, Michael

    2008-09-01

    Two-dimensional ion chamber arrays are primarily used for conventional and intensity modulated radiotherapy quality assurance. There is no commercial device of such type available on the market that is offered for proton therapy quality assurance. We have investigated suitability of the MatriXX, a commercial two-dimensional ion chamber array detector for proton therapy QA. This device is designed to be used for photon and electron therapy QA. The device is equipped with 32 x 32 parallel plate ion chambers, each with 4.5 mm diam and 7.62 mm center-to-center separation. A 250 MeV proton beam was used to calibrate the dose measured by this device. The water equivalent thickness of the buildup material was determined to be 3.9 mm using a 160 MeV proton beam. Proton beams of different energies were used to measure the reproducibility of dose output and to evaluate the consistency in the beam flatness and symmetry measured by MatriXX. The output measurement results were compared with the clinical commissioning beam data that were obtained using a 0.6 cc Farmer chamber. The agreement was consistently found to be within 1%. The profiles were compared with film dosimetry and also with ion chamber data in water with an excellent agreement. The device is found to be well suited for quality assurance of proton therapy beams. It provides fast two-dimensional dose distribution information in real time with the accuracy comparable to that of ion chamber measurements and film dosimetry.

  11. Field computation for two-dimensional array transducers with limited diffraction array beams.

    Science.gov (United States)

    Lu, Jian-Yu; Cheng, Jiqi

    2005-10-01

    A method is developed for calculating fields produced with a two-dimensional (2D) array transducer. This method decomposes an arbitrary 2D aperture weighting function into a set of limited diffraction array beams. Using the analytical expressions of limited diffraction beams, arbitrary continuous wave (cw) or pulse wave (pw) fields of 2D arrays can be obtained with a simple superposition of these beams. In addition, this method can be simplified and applied to a 1D array transducer of a finite or infinite elevation height. For beams produced with axially symmetric aperture weighting functions, this method can be reduced to the Fourier-Bessel method studied previously where an annular array transducer can be used. The advantage of the method is that it is accurate and computationally efficient, especially in regions that are not far from the surface of the transducer (near field), where it is important for medical imaging. Both computer simulations and a synthetic array experiment are carried out to verify the method. Results (Bessel beam, focused Gaussian beam, X wave and asymmetric array beams) show that the method is accurate as compared to that using the Rayleigh-Sommerfeld diffraction formula and agrees well with the experiment.

  12. Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout

    CERN Document Server

    Lin, Tai-Hua; Schott, Matthias; Valderanis, Chrysostomos; Wehner, Laura; Westenberger, Robert

    2014-01-01

    In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip micromegas detector with a two-dimensional readout, based on test-beam and X-ray measurements. In particular, comparisons of the response of the two independent readout-layers regarding their signal shapes and signal reconstruction efficiencies are discussed.

  13. Design and experimental study of a two-dimensional position sensitive X-ray detector

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mmx200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector.

  14. LDRD final report on Bloch Oscillations in two-dimensional nanostructure arrays for high frequency applications.

    Energy Technology Data Exchange (ETDEWEB)

    Lyo, Sungkwun Kenneth; Pan, Wei; Reno, John Louis; Wendt, Joel Robert; Barton, Daniel Lee

    2008-09-01

    We have investigated the physics of Bloch oscillations (BO) of electrons, engineered in high mobility quantum wells patterned into lateral periodic arrays of nanostructures, i.e. two-dimensional (2D) quantum dot superlattices (QDSLs). A BO occurs when an electron moves out of the Brillouin zone (BZ) in response to a DC electric field, passing back into the BZ on the opposite side. This results in quantum oscillations of the electron--i.e., a high frequency AC current in response to a DC voltage. Thus, engineering a BO will yield continuously electrically tunable high-frequency sources (and detectors) for sensor applications, and be a physics tour-de-force. More than a decade ago, Bloch oscillation (BO) was observed in a quantum well superlattice (QWSL) in short-pulse optical experiments. However, its potential as electrically biased high frequency source and detector so far has not been realized. This is partially due to fast damping of BO in QWSLs. In this project, we have investigated the possibility of improving the stability of BO by fabricating lateral superlattices of periodic coupled nanostructures, such as metal grid, quantum (anti)dots arrays, in high quality GaAs/Al{sub x}Ga{sub 1-x}As heterostructures. In these nanostructures, the lateral quantum confinement has been shown theoretically to suppress the optical-phonon scattering, believed to be the main mechanism for fast damping of BO in QWSLs. Over the last three years, we have made great progress toward demonstrating Bloch oscillations in QDSLs. In the first two years of this project, we studied the negative differential conductance and the Bloch radiation induced edge-magnetoplasmon resonance. Recently, in collaboration with Prof. Kono's group at Rice University, we investigated the time-domain THz magneto-spectroscopy measurements in QDSLs and two-dimensional electron systems. A surprising DC electrical field induced THz phase flip was observed. More measurements are planned to investigate this

  15. Efficient processing of two-dimensional arrays with C or C++

    Science.gov (United States)

    Donato, David I.

    2017-07-20

    Because fast and efficient serial processing of raster-graphic images and other two-dimensional arrays is a requirement in land-change modeling and other applications, the effects of 10 factors on the runtimes for processing two-dimensional arrays with C and C++ are evaluated in a comparative factorial study. This study’s factors include the choice among three C or C++ source-code techniques for array processing; the choice of Microsoft Windows 7 or a Linux operating system; the choice of 4-byte or 8-byte array elements and indexes; and the choice of 32-bit or 64-bit memory addressing. This study demonstrates how programmer choices can reduce runtimes by 75 percent or more, even after compiler optimizations. Ten points of practical advice for faster processing of two-dimensional arrays are offered to C and C++ programmers. Further study and the development of a C and C++ software test suite are recommended.Key words: array processing, C, C++, compiler, computational speed, land-change modeling, raster-graphic image, two-dimensional array, software efficiency

  16. Self-Organized Two-Dimensional Vidro-Nanodot Array on Laser-Irradiated Si Surface

    Science.gov (United States)

    Yoshida, Yutaka; Sakaguchi, Norihito; Watanabe, Seiichi; Kato, Takahiko

    2011-05-01

    We report a periodic two-dimensional (2D) array of uniquely shaped dotlike nanoprotrusions (NPs), which simultaneously self-organize on a Si surface under pulsed laser irradiation. The shape of the dotlike NPs can be controlled by adjusting the number of laser pulses. The flask-shaped dotlike NP array is named a vidro-nanodot (VND) array. We present a detailed analysis of the internal structure of VND using high-resolution electron microscopy.

  17. Simulation of vortex motion in underdamped two-dimensional arrays of Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    Bobbert, P.A. (Department of Applied Physics, Delft University of Technology, Lorentweg 1, 2628 CJ Delft (Netherlands) Department of Physics and Division of Applied Sciences, Harvard University, Cambridge, Massachusetts 02138 (United States))

    1992-04-01

    We report numerical simulations of classical vortex motion in two-dimensional arrays of underdamped Josephson junctions. A very efficient algorithm was developed, using a piecewise linear approximation for the Josephson current. We find no indication for ballistic motion, in square arrays nor in triangular arrays. Instead, in the limit of very low damping, there appears to be an effective viscosity due to excitation of the lattice behind the moving vortex.

  18. Two-dimensional array of nanoparticles intermitted by long chain molecules

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    It is an important theme in nanoscience to control the interval of the ordered array of nanoparticles through modifying the chain length of the passivating molecules of the nanoparticles. The theme runs through most of the applications of the ordered array of nanoparticles. Though the Langmuir-Blodgett (LB) technique is one of the most important ways to prepare the two- dimensional ordered array of nanoparticles, it has only been used in case that the passivating molecules are short enough (array of the particles simply by compressing them on the surface of water. The present work focused on the formation of the two-dimensional array of the octadecyl- amine-passivated gold nanoparticles at the air/water interface. By properly modifying the ordinary LB technique, the long-term two-dimensional ordered array of nanoparticles was successfully achieved. The surface pressure-area isotherms and the electron microscopy observation showed that the key to preparing the two-dimensional ordered arrangement of nanoparticles is to overcome the interaction among the passivant shells.

  19. Non-Hermitian engineering of single mode two dimensional laser arrays

    CERN Document Server

    Teimourpour, Mohammad H; Christodoulides, Demetrios N; El-Ganainy, Ramy

    2016-01-01

    A new scheme for building two dimensional laser arrays that operate in the single supermode regime is proposed. This is done by introducing an optical coupling between the laser array and a lossy pseudo-isospectral chain of photonic resonators. The spectrum of this discrete reservoir is tailored to suppress all the supermodes of the main array except the fundamental one. This spectral engineering is facilitated by employing the Householder transformation in conjunction with discrete supersymmetry. The proposed scheme is general and can in principle be used in different platforms such as VCSEL arrays and photonic crystal laser arrays.

  20. Silicon strip detectors for two-dimensional soft X-ray imaging at normal incidence

    Energy Technology Data Exchange (ETDEWEB)

    Rato Mendes, P. E-mail: rato@lip.pt; Abreu, M.C.; Baldazzi, G.; Bollini, D.; Cabal Rodriguez, A.E.; Dabrowski, W.; Diaz Garcia, A.; Gambaccini, M.; Giubellino, P.; Gombia, M.; Grybos, P.; Idzik, M.; Marzari-Chiesa, A.; Montano, L.M.; Prino, F.; Ramello, L.; Rodrigues, S.; Sitta, M.; Sousa, P.; Swientek, K.; Taibi, A.; Tuffanelli, A.; Wheadon, R.; Wiacek, P

    2003-08-21

    A simple prototype system for static two-dimensional soft X-ray imaging using silicon microstrip detectors irradiated at normal incidence is presented. Radiation sensors consist of single-sided silicon detectors made from 300 {mu}m thick wafers, read by RX64 ASICs. Data acquisition and control is performed by a Windows PC workstation running dedicated LabVIEW routines, connected to the sensors through a PCI-DIO-96 interface. Two-dimensional images are obtained by scanning a lead collimator with a thin slit perpendicular to the strip axis, along the whole detector size; the several strip profiles (slices) taken at each position are then put together to form a planar image. Preliminary results are presented, illustrating the high-resolution imaging capabilities of the system with soft X-rays.

  1. An atom-by-atom assembler of defect-free arbitrary two-dimensional atomic arrays

    Science.gov (United States)

    Barredo, Daniel; de Léséleuc, Sylvain; Lienhard, Vincent; Lahaye, Thierry; Browaeys, Antoine

    2016-11-01

    Large arrays of individually controlled atoms trapped in optical tweezers are a very promising platform for quantum engineering applications. However, deterministic loading of the traps is experimentally challenging. We demonstrate the preparation of fully loaded two-dimensional arrays of up to ~50 microtraps, each containing a single atom and arranged in arbitrary geometries. Starting from initially larger, half-filled matrices of randomly loaded traps, we obtain user-defined target arrays at unit filling. This is achieved with a real-time control system and a moving optical tweezers, which together enable a sequence of rapid atom moves depending on the initial distribution of the atoms in the arrays. These results open exciting prospects for quantum engineering with neutral atoms in tunable two-dimensional geometries.

  2. Analysis of directional dependence of the two-dimensional array of detectors 2D array seven 29 implications in the planning system; Analisis de la dependencia direcccional de la matriz bidimensional de detectores 2D array seven29. Implicaciones en el sistema de planificacion

    Energy Technology Data Exchange (ETDEWEB)

    Mora Melendez, R.; Seguro Fernandez, A.; Iborra Oquendo, M.; Urena Llinares, A.

    2013-07-01

    The main objective of our study is to find correction factors dependent on the 2D array incidence angles, and to give account of the phenomenon, allowing the Planner to faithfully reproduce data and curves measured experimentally. (Author)

  3. Scalable loading of a two-dimensional trapped-ion array

    Science.gov (United States)

    Bruzewicz, Colin D.; McConnell, Robert; Chiaverini, John; Sage, Jeremy M.

    2016-09-01

    Two-dimensional arrays of trapped-ion qubits are attractive platforms for scalable quantum information processing. Sufficiently rapid reloading capable of sustaining a large array, however, remains a significant challenge. Here with the use of a continuous flux of pre-cooled neutral atoms from a remotely located source, we achieve fast loading of a single ion per site while maintaining long trap lifetimes and without disturbing the coherence of an ion quantum bit in an adjacent site. This demonstration satisfies all major criteria necessary for loading and reloading extensive two-dimensional arrays, as will be required for large-scale quantum information processing. Moreover, the already high loading rate can be increased by loading ions in parallel with only a concomitant increase in photo-ionization laser power and no need for additional atomic flux.

  4. A large area two-dimensional position sensitive multiwire proportional detector

    CERN Document Server

    Moura, M M D; Souza, F A; Alonso, E E; Fujii, R J; Meyknecht, A B; Added, N; Aissaoui, N; Cardenas, W H Z; Ferraretto, M D; Schnitter, U; Szanto, E M; Szanto de Toledo, A; Yamamura, M S; Carlin, N

    1999-01-01

    Large area two-dimensional position sensitive multiwire proportional detectors were developed to be used in the study of light heavy-ion nuclear reactions at the University of Sao Paulo Pelletron Laboratory. Each detector has a 20x20 cm sup 2 active area and consists of three grids (X-position, anode and Y-position) made of 25 mu m diameter gold plated tungsten wires. The position is determined through resistive divider chains. Results for position resolution, linearity and efficiency as a function of energy and position for different elements are reported.

  5. Two-Dimensional DOA Estimation for Uniform Rectangular Array Using Reduced-Dimension Propagator Method

    Directory of Open Access Journals (Sweden)

    Ming Zhou

    2015-01-01

    Full Text Available A novel algorithm is proposed for two-dimensional direction of arrival (2D-DOA estimation with uniform rectangular array using reduced-dimension propagator method (RD-PM. The proposed algorithm requires no eigenvalue decomposition of the covariance matrix of the receive data and simplifies two-dimensional global searching in two-dimensional PM (2D-PM to one-dimensional local searching. The complexity of the proposed algorithm is much lower than that of 2D-PM. The angle estimation performance of the proposed algorithm is better than that of estimation of signal parameters via rotational invariance techniques (ESPRIT algorithm and conventional PM algorithms, also very close to 2D-PM. The angle estimation error and Cramér-Rao bound (CRB are derived in this paper. Furthermore, the proposed algorithm can achieve automatically paired 2D-DOA estimation. The simulation results verify the effectiveness of the algorithm.

  6. Two-dimensional photon counting imaging detector based on PCB delay line anode

    Science.gov (United States)

    Zhu, Bingli; Bai, Yonglin; Lei, Fanpu; Bai, Xiaohong; Wang, Bo; Qin, Junjun; Cao, Weiwei; Gou, Yongsheng

    2016-11-01

    Delay line anode detector has high spatial resolution and high count rate. It has been an important technical means for single photon imaging from near earth space to deep space. A two dimensional delay line anode is designed using multilayer circuit board technology. A complete set of PCB delay line anode single photon detection system is established. The spatial resolution of the detector is theoretically analyzed. Moreover, the signal transmission characteristic of PCB delay line and the dark count rate of the detector are tested. Theoretical analysis and experimental results show that the detector spatial resolution is about 100um and the overall dark count rate is 4counts/cm2 at 2.3KV.

  7. Comment on "Thermal propagation in two-dimensional Josephson junction arrays"

    OpenAIRE

    De Leo, Cinzia

    2009-01-01

    In a recent paper, Filatrella et al. [Phys. Rev. B 75, 54510 (2007)] report results of numerical calculations of energy barriers for flux quanta propagation in two-dimensional arrays of Josephson junctions with finite self and mutual inductances. To avoid complex numerical calculations, they use an approximated inductance model to address the effects of the mutual couplings. Using a full inductance matrix model, we show that this approximated model cannot be used to calculate the energy barri...

  8. High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

    Science.gov (United States)

    Bush, Brett C.; Cotton, Daniel M.; Siegmund, Oswald H.; Chakrabarti, Supriya; Harris, Walter; Clarke, John

    1991-01-01

    We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

  9. Design and optimization of resistive anode for a two-dimensional imaging GEM detector

    Science.gov (United States)

    Ju, Xu-Dong; Dong, Ming-Yi; Zhao, Yi-Chen; Zhou, Chuan-Xing; Qun, Ou-Yang

    2016-08-01

    A resistive anode for two-dimensional imaging detectors, which consists of a series of high resistivity pads surrounded by low resistivity strips, can provide good spatial resolution while reducing the number of electronics channels required. The optimization of this kind of anode has been studied by both numerical simulations and experimental tests. It is found that to obtain good detector performance, the resistance ratio of the pads to the strips should be larger than 5, the nonuniformity of the pad surface resistivity should be less than 20%, a smaller pad width leads to a smaller spatial resolution, and when the pad width is 6 mm, the spatial resolution (σ) can reach about 105 μm. Based on the study results, a 2-D GEM detector prototype with optimized resistive anode is constructed and a good imaging performance is achieved. Supported by National Natural Science Foundation of China (11375219) and CAS Center for Excellence in Particle Physics (CCEPP)

  10. Quasi-periodic distribution of plasmon modes in two-dimensional Fibonacci arrays of metal nanoparticles.

    Science.gov (United States)

    Dallapiccola, Ramona; Gopinath, Ashwin; Stellacci, Francesco; Dal Negro, Luca

    2008-04-14

    In this paper we investigate for the first time the near-field optical behavior of two-dimensional Fibonacci plasmonic lattices fabricated by electron-beam lithography on transparent quartz substrates. In particular, by performing near-field optical microscopy measurements and three dimensional Finite Difference Time Domain simulations we demonstrate that near-field coupling of nanoparticle dimers in Fibonacci arrays results in a quasi-periodic lattice of localized nanoparticle plasmons. The possibility to accurately predict the spatial distribution of enhanced localized plasmon modes in quasi-periodic Fibonacci arrays can have a significant impact for the design and fabrication of novel nano-plasmonics devices.

  11. Two-dimensional gold nanoparticle arrays. A platform for molecular optoelectronics

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Markus Andreas

    2011-11-15

    In my research, I study the optoelectronic properties of two-dimensional, hexagonal gold nanoparticle arrays formed by self-assembly. When the nanoparticle arrays are embedded in a matrix of alkane thiols, the photoresponse is dominated by a bolometric conductance increase. At room temperature, I observe a strong enhancement of the bolometric photoconductance when the surface plasmon resonance of the nanoparticles is excited. At cryogenic temperatures, the bolometric conductance enhancement leads to a redistribution of the potential landscape which dominates the optoelectronic response of the nanoparticle arrays. When optically active oligo(phenylene vinylene) (OPV) molecules are covalently bound to the nanoparticles, an increased photoconductance due to the resonant excitation of the OPV is observed. The results suggest that the charge carriers, which are resonantly excited in the OPV molecules, directly contribute to the current flow through the nanoparticle arrays. Thus, the conductance of OPV in its excited state is measured in the presented experiments. (orig.)

  12. Micro-LED arrays: a tool for two-dimensional neuron stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Poher, V; Kennedy, G T; French, P M W; Neil, M A A [Blackett Laboratory, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom); Grossman, N; Nikolic, K; Drakakis, E M; Degenaar, P [Institute of Biomedical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom); Zhang, H X; Gong, Z; Gu, E; Dawson, M D [Institute of Photonics, University of Strathclyde, 106 Rottenrow, Glasgow G4 0NW (United Kingdom)], E-mail: vincent.poher@imperial.ac.uk

    2008-05-07

    Stimulating neuron cells with light is an exciting new technology that is revolutionizing the neurosciences. To date, due to the optical complexity that is involved, photostimulation has only been achieved at a single site using high power light sources. Here we present a GaN based micro-light emitting diode (LED) array that can open the way to multi-site photostimulation of neuron cells. The device is a two-dimensional array of micrometre size LED emitters. Each emitter has the required wavelength, optical power and modulation bandwidth to trigger almost any photosensitizer and is individually addressable. We demonstrate micrometre resolution photoactivation of a caged fluorophore and photostimulation of sensitized living neuron cells. In addition, a complete system that combines the micro-LED array with multi-site electrophysiological recording based on microelectrode array technology and/or fluorescence imaging is presented.

  13. Two-dimensional Josephson junction arrays coupled through a high-Q cavity

    DEFF Research Database (Denmark)

    Filatrella, G.; Pedersen, Niels Falsig; Wiesenfeld, K.

    2001-01-01

    the cavity. The highly resonant cavity induces synchronized behavior, which is qualitatively different than what is familiar from other studies on nonlinear oscillator arrays, for example the Kuramoto model. We also address the effects of disorder, as well as the role of detuning between the spontaneous...... emission frequency of the junctions and the cavity resonant frequency. We show with a simple argument that we can predict the scaling behavior of disorder with the size of the array. The consequences for the design of microwave oscillators in the Gigahertz region are discussed......The problem of disordered two-dimensional arrays of underdamped Josephson junctions is addressed. Our simulations show that when coupled to a high-Q cavity, the array exhibits synchronized behavior, and the power emitted can be considerably increased once enough junctions are activated to pump...

  14. Cooperative resonances in light scattering from two-dimensional atomic arrays

    CERN Document Server

    Shahmoon, Ephraim; Lukin, Mikhail D; Yelin, Susanne F

    2016-01-01

    We consider light scattering off a two-dimensional (2D) dipolar array and show how it can be tailored by properly choosing the lattice constant of the order of the incident wavelength. In particular, we demonstrate that such arrays can operate as nearly perfect mirrors for a wide range of incident angles and frequencies close to the individual atomic resonance. These results can be understood in terms of the cooperative resonances of the surface modes supported by the 2D array. Experimental realizations are discussed, using ultracold arrays of trapped atoms and excitons in 2D semiconductor materials, as well as potential applications ranging from atomically thin metasurfaces to single photon nonlinear optics and nanomechanics.

  15. Two-dimensional, single-photoelectron drift detector for Cherenkov ring imaging

    Energy Technology Data Exchange (ETDEWEB)

    Barrelet, E.; Seguinot, J.; Urban, M.; Ypsilantis, T. (Ecole Polytechnique, 91 - Palaiseau (France)); Ekeloef, T. (European Organization for Nuclear Research, Geneva (Switzerland)); Lund-Jensen, B. (Uppsala Univ. (Sweden)); Tocqueville, J. (College de France, 75 - Paris)

    1982-09-15

    A detector capable of imaging single photoelectrons has been constructed and tested. UV photons (>=5.4 eV) are converted to electrons with high quantum efficiency by photoionization of a small admixture (approx. equal to 1 Torr) of an organic vapour TMAE in a predominantly methane drift and amplifying gas at atmospheric pressure. The produced photoelectrons drift in a uniform applied electric field to a picket fence of proportional wires where each electron is amplified, counted and timed. The two-dimensional source point of each photoelectron is uniquely determined by the hit wire address and the arrival time. The detector has been tested by measuring ionization electrons produced in the drift gas be relativistic charged particles. The limiting precision to which the electron source point can be determined has been measured to be 300 ..mu..m (r.m.s.) in the drift direction and 370 ..mu..m in the wire plane direction. Additional independent error sources due to electron diffusion in the drift gas have been measured to be proportional to the square root of the drift distance with a proportionality constant of 235 ..mu..m/cmsup(1/2) in both directions. Drift velocities of electrons in various predominantly methane gas mixtures have been measured as a function of the applied electric field. The utilization of such a two-dimensional single electron drift detector for Cherenkov ring imaging is presented with a discussion of the advantages and limitations of the drift method for imaging.

  16. Progress in two-dimensional arrays for real-time volumetric imaging.

    Science.gov (United States)

    Light, E D; Davidsen, R E; Fiering, J O; Hruschka, T A; Smith, S W

    1998-01-01

    The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology. A 40 x 40 = 1,600 element, 3.5 MHz array was fabricated with 256 transmit and 256 receive elements. A 60 x 60 = 3,600 element 5.0 MHz array was constructed with 248 transmit and 256 receive elements. An 80 x 80 = 6,400 element, 2.5 MHz array was fabricated with 256 transmit and 208receive elements. 2-D transducer arrays were also developed for volumetric scanning in an intra cardiac catheter, a 10 x 10 = 100 element 5.0 MHz forward-looking array and an 11 x 13 = 143 element 5.0 MHz side-scanning array. The-6dB fractional bandwidths for the different arrays varied from 50% to 63%, and the 50 omega insertion loss for all the transducers was about-64 dB. The transducers were used to generate real-time volumetric images in phantoms and in vivo using the Duke University real time volumetric imaging system, which is capable of generating multiple planes at any desired angle and depth within the pyramidal volume.

  17. Two dimensional thermo-optic beam steering using a silicon photonic optical phased array

    Science.gov (United States)

    Mahon, Rita; Preussner, Marcel W.; Rabinovich, William S.; Goetz, Peter G.; Kozak, Dmitry A.; Ferraro, Mike S.; Murphy, James L.

    2016-03-01

    Components for free space optical communication terminals such as lasers, amplifiers, and receivers have all seen substantial reduction in both size and power consumption over the past several decades. However, pointing systems, such as fast steering mirrors and gimbals, have remained large, slow and power-hungry. Optical phased arrays provide a possible solution for non-mechanical beam steering devices that can be compact and lower in power. Silicon photonics is a promising technology for phased arrays because it has the potential to scale to many elements and may be compatible with CMOS technology thereby enabling batch fabrication. For most free space optical communication applications, two-dimensional beam steering is needed. To date, silicon photonic phased arrays have achieved two-dimensional steering by combining thermo-optic steering, in-plane, with wavelength tuning by means of an output grating to give angular tuning, out-of-plane. While this architecture might work for certain static communication links, it would be difficult to implement for moving platforms. Other approaches have required N2 controls for an NxN element phased array, which leads to complexity. Hence, in this work we demonstrate steering using the thermo-optic effect for both dimensions with a simplified steering mechanism requiring only two control signals, one for each steering dimension.

  18. Freely configurable quantum simulator based on a two-dimensional array of individually trapped ions

    CERN Document Server

    Mielenz, Manuel; Wittemer, Matthias; Hakelberg, Frederick; Schmied, Roman; Blain, Matthew; Maunz, Peter; Leibfried, Dietrich; Warring, Ulrich; Schaetz, Tobias

    2015-01-01

    A custom-built and precisely controlled quantum system may offer access to a fundamental understanding of another, less accessible system of interest. A universal quantum computer is currently out of reach, but an analog quantum simulator that makes the relevant observables, interactions, and states of a quantum model accessible could permit experimental insight into complex quantum dynamics that are intractable on conventional computers. Several platforms have been suggested and proof-of-principle experiments have been conducted. Here we characterise two-dimensional arrays of three ions trapped by radio-frequency fields in individually controlled harmonic wells forming equilateral triangles with side lengths 40 and 80 micrometer. In our approach, which is scalable to arbitrary two dimensional lattices, we demonstrate individual control of the electronic and motional degrees of freedom, preparation of a fiducial initial state with ion motion close to the ground state, as well as tuning of crucial couplings be...

  19. Two-dimensional photon counting imaging detector based on a Vernier position sensitive anode readout

    Institute of Scientific and Technical Information of China (English)

    YAN Qiu-Rong; ZHAO Bao-Sheng; LIU Yong-An; YANG Hao; SHENG Li-Zhi; WEI Yong-Lin

    2011-01-01

    A two-dimensional photon counting imaging detector based on a Vernier position sensitive anode is reported. The decode principle and design of a two-dimensionai Vernier anode axe introduced in detail. A photon counting imaging system was built based on a Vernier anode. The image of very weak optical radiation can be reconstructed by image processing in a period of integration time. The resolution is superior to 100 μm according to the resolution test. The detector may realize the imaging of very weak particle flow of high- energy photons, electrons and ions, so it can be used for high-energy physics, deep space exploration, spectral measurement and bio-luminescence detection.

  20. Optimization of micro-strip gas chamber as two-dimensional neutron detector using gadolinium converter

    Energy Technology Data Exchange (ETDEWEB)

    Masaoka, Sei; Nakamura, Tatsuya; Yamagishi, Hideshi; Soyama, Kazuhiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-02-01

    A micro-strip gas chamber (MSGC) has been developing as a two-dimensional position sensitive neutron detector for neutron scattering experiments using high-intensity pulsed-neutron source in a high-intensity proton accelerator facility. MSGC is required for the high count rate, high detective efficiency, high positional resolution, stabilization and covering large area. Our purpose in this paper is to verify the proper of Gadolinium as MSGC converter. First, the basic property of Gadolinium converter was examined by simple experiments using a zero-dimensional neutron detector on the purpose of deriving the detective efficiency. Second, the optimization of the arrangement of a capillary plate in MSGC has been done by simulation on the MSGC using Gadolinium converter. As a result of that, it has been proved that Gadolinium can be theoretically used as a converter of MSGC. (author)

  1. Novel two-dimensional DOA estimation with L-shaped array

    Science.gov (United States)

    Xiaofei, Zhang; Jianfeng, Li; Lingyun, Xu

    2011-12-01

    Two-dimensional (2D) direction-of-arrival (DOA) estimation has played an important role in array signal processing. In this article, we address a problem of bind 2D-DOA estimation with L-shaped array. This article links the 2D-DOA estimation problem to the trilinear model. To exploit this link, we derive a trilinear decomposition-based 2D-DOA estimation algorithm in L-shaped array. Without spectral peak searching and pairing, the proposed algorithm employs well. Moreover, our algorithm has much better 2D-DOA estimation performance than the estimation of signal parameters via rotational invariance technique algorithms and propagator method. Simulation results illustrate validity of the algorithm.

  2. Novel two-dimensional DOA estimation with L-shaped array

    Directory of Open Access Journals (Sweden)

    Xiaofei Zhang

    2011-01-01

    Full Text Available Abstract Two-dimensional (2D direction-of-arrival (DOA estimation has played an important role in array signal processing. In this article, we address a problem of bind 2D-DOA estimation with L-shaped array. This article links the 2D-DOA estimation problem to the trilinear model. To exploit this link, we derive a trilinear decomposition-based 2D-DOA estimation algorithm in L-shaped array. Without spectral peak searching and pairing, the proposed algorithm employs well. Moreover, our algorithm has much better 2D-DOA estimation performance than the estimation of signal parameters via rotational invariance technique algorithms and propagator method. Simulation results illustrate validity of the algorithm.

  3. Correlated rotational switching in two-dimensional self-assembled molecular rotor arrays

    Science.gov (United States)

    Wasio, Natalie A.; Slough, Diana P.; Smith, Zachary C.; Ivimey, Christopher J.; Thomas, Samuel W., III; Lin, Yu-Shan; Sykes, E. Charles H.

    2017-07-01

    Molecular devices are capable of performing a number of functions from mechanical motion to simple computation. Their utility is somewhat limited, however, by difficulties associated with coupling them with either each other or with interfaces such as electrodes. Self-assembly of coupled molecular devices provides an option for the construction of larger entities that can more easily integrate with existing technologies. Here we demonstrate that ordered organometallic arrays can be formed spontaneously by reaction of precursor molecular rotor molecules with a metal surface. Scanning tunnelling microscopy enables individual rotors in the arrays to be switched and the resultant switches in neighbouring rotors imaged. The structure and dimensions of the ordered molecular rotor arrays dictate the correlated switching properties of the internal submolecular rotor units. Our results indicate that self-assembly of two-dimensional rotor crystals produces systems with correlated dynamics that would not have been predicted a priori.

  4. Two-dimensional refractive index modulation by phased array transducers in acousto-optic deflectors.

    Science.gov (United States)

    Wang, Tiansi; Zhang, Chong; Aleksov, Aleksandar; Salama, Islam; Kar, Aravinda

    2017-01-20

    Acousto-optic deflectors are photonic devices that are used for scanning high-power laser beams in advanced microprocessing applications such as marking and direct writing. The operation of conventional deflectors mostly relies on one-dimensional sinusoidal variation of the refractive index in an acousto-optic medium. Sometimes static phased array transducers, such as step configuration or planar configuration transducer architecture, are used to tilt the index modulation planes for achieving higher performance and higher resolution than a single transducer AO device. However, the index can be modulated in two dimensions, and the modulation plane can be tilted arbitrarily by creating dynamic phase gratings in the medium using phased array transducers. This type of dynamic two-dimensional acousto-optic deflector can provide better performance using, for example, a large deflection angle and high diffraction efficiency. This paper utilizes an ultrasonic beam steering approach to study the two-dimensional strain-induced index modulation due to the photoelastic effect. The modulation is numerically simulated, and the effects of various parameters, such as the operating radiofrequency of the transducers, the ultrasonic beam steering angle, and different combinations of pressure on each element of the transducer array, are demonstrated.

  5. Optical matrix for clock distribution and synchronous operation in two-dimensional array devices

    Science.gov (United States)

    Lee, K. S.; Shu, C.

    1996-06-01

    A scheme to generate an optical matrix from a mode-locked Nd:YAG laser has been theoretically explored and experimentally demonstrated. The matrix consists of highly synchronized and sequentially delayed optical pulses suitable for use with two-dimensional array optoelectronic devices and clock distribution system. The output pulses have the same state of polarization and no timing jitter is produced among the elements. Encoded outputs have been generated from the matrix using a set of photomasks. This technique can be applied to high-speed optical parallel processing.

  6. Intelligent pulse light source in the performance calibration system of two-dimensional neutron detector

    Science.gov (United States)

    Yang, Lei; Zhao, Xiao-Fang

    2017-07-01

    Chinese Spallation Neutron Source (CSNS) project will use numerous two-dimensional (2D) neutron detectors whose ZnS (Ag) scintillator is doped with 6Li. To ensure the consistency of all neutron detectors, a calibration system for the performance of 2D neutron detectors is designed. For radiation protection, the state control of the radiation source gets more and more strict. It is impossible to directly carry out experiments with massive radioactive particles. Thus, the following scheme has been designed. The controlled pulsed laser light source on a 2D mobile platform is used to replace the neutron bombardment to generate the photon. The pulse signal drives the laser diode to generate pulse light. The pulse light source located on the 2D platform is controlled by the core controller, and goes to the wavelength shift fiber through the optical fiber. The host computer (PC) receives the signal from the electronics system, processes data, and automatically calibrates the performance parameters. As shown by the experimental results, the pulse light source can perfectly meet all requirements of 2D neutron detector calibration system.

  7. Modulating two-dimensional non-close-packed colloidal crystal arrays by deformable soft lithography.

    Science.gov (United States)

    Li, Xiao; Wang, Tieqiang; Zhang, Junhu; Yan, Xin; Zhang, Xuemin; Zhu, Difu; Li, Wei; Zhang, Xun; Yang, Bai

    2010-02-16

    We report a simple method to fabricate two-dimensional (2D) periodic non-close-packed (ncp) arrays of colloidal microspheres with controllable lattice spacing, lattice structure, and pattern arrangement. This method combines soft lithography technique with controlled deformation of polydimethylsiloxane (PDMS) elastomer to convert 2D hexagonal close-packed (hcp) silica microsphere arrays into ncp ones. Self-assembled 2D hcp microsphere arrays were transferred onto the surface of PDMS stamps using the lift-up technique, and then their lattice spacing and lattice structure could be adjusted by solvent swelling or mechanical stretching of the PDMS stamps. Followed by a modified microcontact printing (microcp) technique, the as-prepared 2D ncp microsphere arrays were transferred onto a flat substrate coated with a thin film of poly(vinyl alcohol) (PVA). After removing the PVA film by calcination, the ncp arrays that fell on the substrate without being disturbed could be lifted up, deformed, and transferred again by another PDMS stamp; therefore, the lattice feature could be changed step by step. Combining isotropic solvent swelling and anisotropic mechanical stretching, it is possible to change hcp colloidal arrays into full dimensional ncp ones in all five 2D Bravais lattices. This deformable soft lithography-based lift-up process can also generate patterned ncp arrays of colloidal crystals, including one-dimensional (1D) microsphere arrays with designed structures. This method affords opportunities and spaces for fabrication of novel and complex structures of 1D and 2D ncp colloidal crystal arrays, and these as-prepared structures can be used as molds for colloidal lithography or prototype models for optical materials.

  8. Scalable Loading of a Two-Dimensional Trapped-Ion Array

    CERN Document Server

    Bruzewicz, C D; Chiaverini, J; Sage, J M

    2015-01-01

    We describe rapid, random-access loading of a two-dimensional (2D) surface-electrode ion-trap array based on two crossed photo-ionization laser beams. With the use of a continuous flux of pre-cooled neutral atoms from a remotely-located source, we achieve loading of a single ion per site while maintaining long trap lifetimes and without disturbing the coherence of an ion quantum bit in an adjacent site. This demonstration satisfies all major criteria necessary for loading and reloading extensive 2D arrays, as will be required for large-scale quantum information processing. Moreover, the already high loading rate can be increased by loading ions in parallel with only a concomitant increase in photo-ionization laser power and no need for additional atomic flux.

  9. Spectral locking in an extended area two-dimensional coherent grating surface emitting laser array

    Energy Technology Data Exchange (ETDEWEB)

    DeFreez, R.K.; Ximen, H.; Bossert, D.J.; Hunt, J.M.; Wilson, G.A.; Elliott, R.A.; Orloff, J. (Dept. of Applied Physics and Electrical Engineering, Oregon Graduate Center, Beaverton, OR (US)); Evans, G.A.; Carlson, N.W.; Lurie, M. (David Sarnoff Research Center, Princeton, NJ (US))

    1990-01-01

    The spectral properties of a monolithic pair of two-dimensional coherent grating surface emitting laser arrays optically coupled by means of total-internal-reflection (TIR) corner turning mirrors have been studied. Each of the pair consists of six groups of ten laterally {ital Y}-coupled, index-guided ridge lasers interspersed with second-order DBR grating sections in the longitudinal direction to provide feedback and surface emitting output coupling. The turning mirrors were formed by focused-ion-beam micromachining channels in the wafer angled at 45{degrees} to the laser waveguide. Locking of the emission spectra of the pair of GSE arrays and shifting of the spectrum of one of the pair by varying the drive current to one gain section in the other is demonstrated.

  10. Two-dimensional DOA Estimation with High Accuracy for MIMO Radar Using Cross Array

    Directory of Open Access Journals (Sweden)

    Liang Hao

    2016-06-01

    Full Text Available In this study, we investigate the estimation of the Two-Dimensional (2D Direction Of Arrival (DOA in monostatic multiple-input–multiple-output radar with cross array and propose a novel, highly accurate DOA estimation method based on unitary transformation. First, we design a new unitary matrix using the central symmetry of a cross array at transmit and receive sites. Then, the rotational invariance relationships of these arrays with long and short baselines can be transformed into a real-value field via unitary transformation. In addition, non-ambiguous and highly accurate 2D DOA estimations can be obtained using a unitary dual-resolution ESPRIT algorithm. Simulations show that the proposed method can estimate 2D highly accurate spatial angles using automatic pairing without incurring the expense of array aperture and peak searching. Compared with traditional unitary transformation, the steering vectors of transmit and receive arrays can be transformed into real-value fields via the unitary matrix and the transformation method of our scheme, respectively. This effectively overcomes the problem of shift invariance factors in real-value fields that cannot be extracted using traditional algorithms. Therefore, the proposed method can absolutely compute eigenvalue decomposition and estimate parameters in a real-value field, resulting in lower computational complexity compared with traditional methods. Simulation results verify both the correctness of our theoretical analysis and the effectiveness of the proposed algorithm.

  11. Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

    Science.gov (United States)

    Lin, Liyong; Kang, Minglei; Solberg, Timothy D; Mertens, Thierry; Baeumer, Christian; Ainsley, Christopher G; McDonough, James E

    2015-05-08

    The need to accurately and efficiently verify both output and dose profiles creates significant challenges in quality assurance of pencil beam scanning (PBS) proton delivery. A system for PBS QA has been developed that combines a new two-dimensional ionization chamber array in a waterproof housing that is scanned in a water phantom. The MatriXX PT has the same detector array arrangement as the standard MatriXX(Evolution) but utilizes a smaller 2 mm plate spacing instead of 5mm. Because the bias voltage of the MatriXX PT and Evolution cannot be changed, PPC40 and FC65-G ionization chambers were used to assess recombination effects. The PPC40 is a parallel plate chamber with an electrode spacing of 2mm, while the FC65-G is a Farmer chamber FC65-G with an electrode spacing of 2.8 mm. Three bias voltages (500, 200, and 100 V) were used for both detectors to determine which radiation type (continuous, pulse or pulse-scanned beam) could closely estimate Pion from the ratios of charges collected. In comparison with the MatriXX(Evolution), a significant improvement in measurement of absolute dose with the MatriXX PT was observed. While dose uncertainty of the MatriXX(Evolution) can be up to 4%, it is 1%; chambers with an electrode spacing of 2 mm or smaller are recommended.

  12. Spontaneous assembly of chemically encoded two-dimensional coacervate droplet arrays by acoustic wave patterning

    Science.gov (United States)

    Tian, Liangfei; Martin, Nicolas; Bassindale, Philip G.; Patil, Avinash J.; Li, Mei; Barnes, Adrian; Drinkwater, Bruce W.; Mann, Stephen

    2016-10-01

    The spontaneous assembly of chemically encoded, molecularly crowded, water-rich micro-droplets into periodic defect-free two-dimensional arrays is achieved in aqueous media by a combination of an acoustic standing wave pressure field and in situ complex coacervation. Acoustically mediated coalescence of primary droplets generates single-droplet per node micro-arrays that exhibit variable surface-attachment properties, spontaneously uptake dyes, enzymes and particles, and display spatial and time-dependent fluorescence outputs when exposed to a reactant diffusion gradient. In addition, coacervate droplet arrays exhibiting dynamical behaviour and exchange of matter are prepared by inhibiting coalescence to produce acoustically trapped lattices of droplet clusters that display fast and reversible changes in shape and spatial configuration in direct response to modulations in the acoustic frequencies and fields. Our results offer a novel route to the design and construction of `water-in-water' micro-droplet arrays with controllable spatial organization, programmable signalling pathways and higher order collective behaviour.

  13. An Improved Zero Potential Circuit for Readout of a Two-Dimensional Resistive Sensor Array.

    Science.gov (United States)

    Wu, Jian-Feng; Wang, Feng; Wang, Qi; Li, Jian-Qing; Song, Ai-Guo

    2016-12-06

    With one operational amplifier (op-amp) in negative feedback, the traditional zero potential circuit could access one element in the two-dimensional (2-D) resistive sensor array with the shared row-column fashion but it suffered from the crosstalk problem for the non-scanned elements' bypass currents, which were injected into array's non-scanned electrodes from zero potential. Firstly, for suppressing the crosstalk problem, we designed a novel improved zero potential circuit with one more op-amp in negative feedback to sample the total bypass current and calculate the precision resistance of the element being tested (EBT) with it. The improved setting non-scanned-electrode zero potential circuit (S-NSE-ZPC) was given as an example for analyzing and verifying the performance of the improved zero potential circuit. Secondly, in the S-NSE-ZPC and the improved S-NSE-ZPC, the effects of different parameters of the resistive sensor arrays and their readout circuits on the EBT's measurement accuracy were simulated with the NI Multisim 12. Thirdly, part features of the improved circuit were verified with the experiments of a prototype circuit. Followed, the results were discussed and the conclusions were given. The experiment results show that the improved circuit, though it requires one more op-amp, one more resistor and one more sampling channel, can access the EBT in the 2-D resistive sensor array more accurately.

  14. Development of a two-dimensional imaging GEM detector using the resistive anode readout method with $6\\times6$ cells

    CERN Document Server

    Ju, Xu-Dong; Zhou, Chuan-Xing; Dong, Jing; Zhao, Yu-Bin; Zhang, Hong-Yu; Qi, Hui-Rong; Ou-Yang, Qun

    2016-01-01

    We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists $6\\times6$ cells with the cell size $6~\\mathrm{mm}\\times6~\\mathrm{mm}$. New electronics and DAQ system are used to process the signals from 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the detector is about $103.46~\\mathrm{{\\mu}m}$ with the signal part $66.41~\\mathrm{{\\mu}m}$. The nonlinearity of the detector is less than $0.5\\%$. A good two dimensional imaging capability is achieved as well. The performances of the detector show the prospect of the resistive anode readout method for the large readout area imaging detectors.

  15. Water-channel study of flow and turbulence past a two-dimensional array of obstacles

    CERN Document Server

    Di Bernardino, Annalisa; Leuzzi, Giovanni; Querzoli, Giorgio

    2016-01-01

    A neutral boundary layer was generated in the laboratory to analyze the mean velocity field and the turbulence field within and above an array of two-dimensional obstacles simulating an urban canopy. Different geometrical configurations were considered in order to investigate the main characteristics of the flow as a function of the aspect ratio (AR) of the canopy. To this end, a summary of the two-dimensional fields of the fundamental turbulence parameters is given for AR ranging from 1 to 2. The results show that the flow field depends strongly on AR only within the canyon, while the outer flow seems to be less sensitive to this parameter. This is not true for the vertical momentum flux, which is one of the parameters most affected by AR, both within and outside the canyon. The experiments also indicate that, when (i.e. the skimming flow regime), the roughness sub-layer extends up to a height equal to 1.25 times the height of the obstacles (H), surmounted by an inertial sub-layer that extends up to 2.7 H. I...

  16. Range imaging pulsed laser sensor with two-dimensional scanning of transmitted beam and scanless receiver using high-aspect avalanche photodiode array for eye-safe wavelength

    Science.gov (United States)

    Tsuji, Hidenobu; Imaki, Masaharu; Kotake, Nobuki; Hirai, Akihito; Nakaji, Masaharu; Kameyama, Shumpei

    2017-03-01

    We demonstrate a range imaging pulsed laser sensor with two-dimensional scanning of a transmitted beam and a scanless receiver using a high-aspect avalanche photodiode (APD) array for the eye-safe wavelength. The system achieves a high frame rate and long-range imaging with a relatively simple sensor configuration. We developed a high-aspect APD array for the wavelength of 1.5 μm, a receiver integrated circuit, and a range and intensity detector. By combining these devices, we realized 160×120 pixels range imaging with a frame rate of 8 Hz at a distance of about 50 m.

  17. Fabrication of Pop-up Detector Arrays on Si Wafers

    Science.gov (United States)

    Li, Mary J.; Allen, Christine A.; Gordon, Scott A.; Kuhn, Jonathan L.; Mott, David B.; Stahle, Caroline K.; Wang, Liqin L.

    1999-01-01

    High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way

  18. Development of a Two-Dimensional Tracker with Plasma Panel Detector

    CERN Document Server

    AUTHOR|(CDS)2233132

    Plasma panel sensors are micropattern gaseous radiation detectors which are based on the technology of plasma display panels. This thesis summarizes the research that had been done on commercially available plasma display panels that were converted to plasma panel sensor prototypes and describes the construction of a two-dimensional tracker consisting of four of those prototypes, with one-dimensional readout on each, used to detect tracks of cosmic muons. A large amount of 2-point as well as 3 and 4-point tracks were detected. Qualitative analyses as well as Pearson’s χ2 tests are performed on the track angular distribution and on a histogram of the linearity measure of 3-point tracks to reject the hypothesis that these tracks result from completely random panel hits. Some RF noise effects contributing to false positives are ruled out, while it is shown that other effects can be ruled out only with a high-intensity minimum ionizing particle source. A significant part of the tracker construction was the dev...

  19. Two-dimensional X-ray imaging using plastic scintillating fiber array

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Due to its low cost,flexibility and convenience for long distance dala transfer,plastic scintillation fiber (PSF)have been increasingly used in building detectors or sensors for detecting various radiations and imaging.In this work,the performance of using PSF coupled with charge-coupled devices(CCD)to build are adetectors for 2D X-ray imaging is studied.We describe the experimental setup and show the obtained images from CCD.Modulation Transfer Function(MTF)of the PSF array is also presented and compared to earlier reports.

  20. Theory of tailorable optical response of two-dimensional arrays of plasmonic nanoparticles at dielectric interfaces

    Science.gov (United States)

    Sikdar, Debabrata; Kornyshev, Alexei A.

    2016-01-01

    Two-dimensional arrays of plasmonic nanoparticles at interfaces are promising candidates for novel optical metamaterials. Such systems materialise from ‘top–down’ patterning or ‘bottom–up’ self-assembly of nanoparticles at liquid/liquid or liquid/solid interfaces. Here, we present a comprehensive analysis of an extended effective quasi-static four-layer-stack model for the description of plasmon-resonance-enhanced optical responses of such systems. We investigate in detail the effects of the size of nanoparticles, average interparticle separation, dielectric constants of the media constituting the interface, and the nanoparticle position relative to the interface. Interesting interplays of these different factors are explored first for normally incident light. For off-normal incidence, the strong effects of the polarisation of light are found at large incident angles, which allows to dynamically tune the reflectance spectra. All the predictions of the theory are tested against full-wave simulations, proving this simplistic model to be adequate within the quasi-static limit. The model takes seconds to calculate the system’s optical response and makes it easy to unravel the effect of each system parameter. This helps rapid rationalization of experimental data and understanding of the optical signals from these novel ‘metamaterials’, optimised for light reflection or harvesting. PMID:27652788

  1. Thin catheter bending in the direction perpendicular to ultrasound propagation using two-dimensional array transducer

    Science.gov (United States)

    Suzuki, Toshiya; Mochizuki, Takashi; Ushimizu, Hidetaka; Miyazawa, Shinya; Tsurui, Nobuhiro; Masuda, Kohji

    2017-07-01

    Although we have already experimented on the bending of a thin catheter with acoustic radiation force using a single transducer, it is necessary to develop a method of bending a catheter in an arbitrary direction because the installation position of ultrasound transducers on a body surface is limited for application to various shapes of in vivo blood vessels. Therefore, we examined the bending of a thin catheter in the direction perpendicular to ultrasound propagation using a two-dimensional array transducer (1 MHz), which realizes not only the temporospatial design but also the dynamic variation of acoustic fields. Forming two focal points with opposite phases, where the amplitudes of the two points instantaneously have the positive and negative relationship, we confirmed the bending of a thin catheter in the direction perpendicular to ultrasound propagation. We used a thin catheter (diameter, 200 µm length, 50 mm) to obtain the maximum displacement of 220 µm, where the displacement was proportional to the square of the maximum sound pressure and the duty ratio. From these results, the acoustic energy densities observed in front of and behind the catheter are dominant for the bending of the thin catheter independent of ultrasound propagation. We also found that the distance between two focal points may improve the bending performance without requiring a precise position setting.

  2. Direct-referencing Two-dimensional-array Digital Microfluidics Using Multi-layer Printed Circuit Board

    Science.gov (United States)

    Gong, Jian; Kim, Chang-Jin “CJ”

    2008-01-01

    Digital (i.e. droplet-based) microfluidics, by the electrowetting-on-dielectric (EWOD) mechanism, has shown great potential for a wide range of applications, such as lab-on-a-chip. While most reported EWOD chips use a series of electrode pads essentially in one-dimensional line pattern designed for specific tasks, the desired universal chips allowing user-reconfigurable paths would require the electrode pads in two-dimensional pattern. However, to electrically access the electrode pads independently, conductive lines need to be fabricated underneath the pads in multiple layers, raising a cost issue especially for disposable chip applications. In this article, we report the building of digital microfluidic plates based on a printed-circuit-board (PCB), in which multilayer electrical access lines were created inexpensively using mature PCB technology. However, due to its surface topography and roughness and resulting high resistance against droplet movement, as-fabricated PCB surfaces require unacceptably high (~500 V) voltages unless coated with or immersed in oil. Our goal is EWOD operations of aqueous droplets not only on oil-covered but also on dry surfaces. To meet varying levels of performances, three types of gradually complex post-PCB microfabrication processes are developed and evaluated. By introducing land-grid-array (LGA) sockets in the packaging, a scalable digital microfluidics system with reconfigurable and low-cost chip is also demonstrated. PMID:19234613

  3. Two Dimensional Array of Piezoresistive Nanomechanical Membrane-Type Surface Stress Sensor (MSS with Improved Sensitivity

    Directory of Open Access Journals (Sweden)

    Nico F. de Rooij

    2012-11-01

    Full Text Available We present a new generation of piezoresistive nanomechanical Membrane-type Surface stress Sensor (MSS chips, which consist of a two dimensional array of MSS on a single chip. The implementation of several optimization techniques in the design and microfabrication improved the piezoresistive sensitivity by 3~4 times compared to the first generation MSS chip, resulting in a sensitivity about ~100 times better than a standard cantilever-type sensor and a few times better than optical read-out methods in terms of experimental signal-to-noise ratio. Since the integrated piezoresistive read-out of the MSS can meet practical requirements, such as compactness and not requiring bulky and expensive peripheral devices, the MSS is a promising transducer for nanomechanical sensing in the rapidly growing application fields in medicine, biology, security, and the environment. Specifically, its system compactness due to the integrated piezoresistive sensing makes the MSS concept attractive for the instruments used in mobile applications. In addition, the MSS can operate in opaque liquids, such as blood, where optical read-out techniques cannot be applied.

  4. Tunable two-dimensional arrays of single Rydberg atoms for realizing quantum Ising models.

    Science.gov (United States)

    Labuhn, Henning; Barredo, Daniel; Ravets, Sylvain; de Léséleuc, Sylvain; Macrì, Tommaso; Lahaye, Thierry; Browaeys, Antoine

    2016-06-30

    Spin models are the prime example of simplified many-body Hamiltonians used to model complex, strongly correlated real-world materials. However, despite the simplified character of such models, their dynamics often cannot be simulated exactly on classical computers when the number of particles exceeds a few tens. For this reason, quantum simulation of spin Hamiltonians using the tools of atomic and molecular physics has become a very active field over the past years, using ultracold atoms or molecules in optical lattices, or trapped ions. All of these approaches have their own strengths and limitations. Here we report an alternative platform for the study of spin systems, using individual atoms trapped in tunable two-dimensional arrays of optical microtraps with arbitrary geometries, where filling fractions range from 60 to 100 per cent. When excited to high-energy Rydberg D states, the atoms undergo strong interactions whose anisotropic character opens the way to simulating exotic matter. We illustrate the versatility of our system by studying the dynamics of a quantum Ising-like spin-1/2 system in a transverse field with up to 30 spins, for a variety of geometries in one and two dimensions, and for a wide range of interaction strengths. For geometries where the anisotropy is expected to have small effects on the dynamics, we find excellent agreement with ab initio simulations of the spin-1/2 system, while for strongly anisotropic situations the multilevel structure of the D states has a measurable influence. Our findings establish arrays of single Rydberg atoms as a versatile platform for the study of quantum magnetism.

  5. Plasmonic black metals via radiation absorption by two-dimensional arrays of ultra-sharp convex grooves

    DEFF Research Database (Denmark)

    Beermann, Jonas; Eriksen, René L.; Stær, Tobias Holmgaard;

    2014-01-01

    Plasmonic black surfaces formed by two-dimensional arrays of ultra-sharp convex metal grooves, in which the incident radiation is converted into gap surface plasmon polaritons (GSPPs) and subsequently absorbed (via adiabatic nanofocusing), are fabricated and investigated experimentally for gold...

  6. Combining Multiple Electrode Arrays for Two-Dimensional Electrical Resistivity Imaging Using the Unsupervised Classification Technique

    Science.gov (United States)

    Ishola, K. S.; Nawawi, M. N. M.; Abdullah, K.

    2015-06-01

    This article describes the use of k-means clustering, an unsupervised image classification technique, to help interpret subsurface targets. The k-means algorithm is employed to combine and classify the two-dimensional (2D) inverse resistivity models obtained from three different electrode arrays. The algorithm is initialized through the selection of the number of clusters, number of iterations and other parameters such as stopping criteria. Automatically, it seeks to find groups of closely related resistivity values that belong to the same cluster and are more similar to each other than resistivity values belonging to other clusters. The approach is applied to both synthetic and field data. The 2D postinversions of the resistivity data were preprocessed by resampling and interpolating to the same coordinate. Following the preprocessing, the three images are combined into a single classified image. All the image preprocessing, manipulation and analysis are performed using the PCI Geomatics software package. The results of the clustering and classification are presented as classified images. An assessment of the performance of the individual and combined images for the synthetic models is carried out using an error matrix, mean absolute error and mean absolute percent error. The estimated errors show that images obtained from maximum values of the reconstructed resistivity for the different models give the best representation of the true models. Additionally, the overall accuracy and kappa values show good agreement between the combined classified images and true models. Depending on the model, the overall accuracy ranges from 86 to 99 %, while the kappa coefficient is in the range of 54-98 %. Classified images with kappa coefficients greater than 0.8 show strong agreement, while images with kappa coefficients greater than 0.5 but less than 0.8 give moderate agreement. For the field data, the k-mean classifier produces images that incorporate structural features of

  7. Metamaterials for Remote Generation of Spatially Controllable Two Dimensional Array of Microplasma

    Science.gov (United States)

    Singh, Pramod K.; Hopwood, Jeffrey; Sonkusale, Sameer

    2014-08-01

    Since the initial demonstration of negative refraction and cloaking using metamaterials, there has been enormous interest and progress in making practical devices based on metamaterials such as electrically small antennas, absorbers, modulators, detectors etc that span over a wide range of electromagnetic spectrum covering microwave, terahertz, infrared (IR) and optical wavelengths. We present metamaterial as an active substrate where each unit cell serves as an element for generation of plasma, the fourth state of matter. Sub-wavelength localization of incident electromagnetic wave energy, one of the most interesting properties of metamaterials is employed here for generating high electric field to ignite and sustain microscale plasmas. Frequency selective nature of the metamaterial unit cells make it possible to generate spatially localized microplasma in a large array using multiple resonators. A dual resonator topology is shown for the demonstration. Since microwave energy couples to the metamaterial through free space, the proposed approach is naturally wireless. Such spatially controllable microplasma arrays provide a fundamentally new material system for future investigations in novel applications, e.g. nonlinear metamaterials.

  8. Metamaterials for remote generation of spatially controllable two dimensional array of microplasma.

    Science.gov (United States)

    Singh, Pramod K; Hopwood, Jeffrey; Sonkusale, Sameer

    2014-08-07

    Since the initial demonstration of negative refraction and cloaking using metamaterials, there has been enormous interest and progress in making practical devices based on metamaterials such as electrically small antennas, absorbers, modulators, detectors etc that span over a wide range of electromagnetic spectrum covering microwave, terahertz, infrared (IR) and optical wavelengths. We present metamaterial as an active substrate where each unit cell serves as an element for generation of plasma, the fourth state of matter. Sub-wavelength localization of incident electromagnetic wave energy, one of the most interesting properties of metamaterials is employed here for generating high electric field to ignite and sustain microscale plasmas. Frequency selective nature of the metamaterial unit cells make it possible to generate spatially localized microplasma in a large array using multiple resonators. A dual resonator topology is shown for the demonstration. Since microwave energy couples to the metamaterial through free space, the proposed approach is naturally wireless. Such spatially controllable microplasma arrays provide a fundamentally new material system for future investigations in novel applications, e.g. nonlinear metamaterials.

  9. Spatially correlated two-dimensional arrays of semiconductor and metal quantum dots in GaAs-based heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Nevedomskiy, V. N., E-mail: nevedom@mail.ioffe.ru; Bert, N. A.; Chaldyshev, V. V. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation); Preobrazhernskiy, V. V.; Putyato, M. A.; Semyagin, B. R. [Russian Academy of Sciences, Institute of Semiconductor Physics, Siberian Branch (Russian Federation)

    2015-12-15

    A single molecular-beam epitaxy process is used to produce GaAs-based heterostructures containing two-dimensional arrays of InAs semiconductor quantum dots and AsSb metal quantum dots. The twodimensional array of AsSb metal quantum dots is formed by low-temperature epitaxy which provides a large excess of arsenic in the epitaxial GaAs layer. During the growth of subsequent layers at a higher temperature, excess arsenic forms nanoinclusions, i.e., metal quantum dots in the GaAs matrix. The two-dimensional array of such metal quantum dots is created by the δ doping of a low-temperature GaAs layer with antimony which serves as a precursor for the heterogeneous nucleation of metal quantum dots and accumulates in them with the formation of AsSb metal alloy. The two-dimensional array of InAs semiconductor quantum dots is formed via the Stranski–Krastanov mechanism at the GaAs surface. Between the arrays of metal and semiconductor quantum dots, a 3-nm-thick AlAs barrier layer is grown. The total spacing between the arrays of metal and semiconductor quantum dots is 10 nm. Electron microscopy of the structure shows that the arrangement of metal quantum dots and semiconductor quantum dots in the two-dimensional arrays is spatially correlated. The spatial correlation is apparently caused by elastic strain and stress fields produced by both AsSb metal and InAs semiconductor quantum dots in the GaAs matrix.

  10. A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout

    Energy Technology Data Exchange (ETDEWEB)

    Hanu, A.R., E-mail: hanua@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada L8S 4K1 (Canada); NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Prestwich, W.V.; Byun, S.H. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, Canada L8S 4K1 (Canada)

    2015-04-21

    We present a data acquisition (DAQ) system for two-dimensional position sensitive micropattern gas detectors using the delay-line method for readout. The DAQ system consists of a field programmable gate array (FPGA) as the main data processor and our time-to-digital (TDC) mezzanine card for making time measurements. We developed the TDC mezzanine card around the Acam TDC-GPX ASIC and it features four independent stop channels referenced to a common start, a typical timing resolution of ~81 ps, and a 17-bit measurement range, and is compliant with the VITA 57.1 standard. For our DAQ system, we have chosen the Xilinx SP601 development kit which features a single Spartan 6 FPGA, 128 MB of DDR2 memory, and a serial USB interface for communication. Output images consist of 1024×1024 square pixels, where each pixel has a 32-bit depth and corresponds to a time difference of 162 ps relative to its neighbours. When configured for a 250 ns acquisition window, the DAQ can resolve periodic event rates up to 1.8×10{sup 6} Hz without any loses and will report a maximum event rate of 6.11×10{sup 5} Hz for events whose arrival times follow Poisson statistics. The integral and differential non-linearities have also been measured and are better than 0.1% and 1.5%, respectively. Unlike commercial units, our DAQ system implements the delay-line image reconstruction algorithm entirely in hardware and is particularly attractive for its modularity, low cost, ease of integration, excellent linearity, and high throughput rate.

  11. Two-Dimensional Time-Domain Antenna Arrays for Optimum Steerable Energy Pattern with Low Side Lobes

    Directory of Open Access Journals (Sweden)

    Alberto Reyna

    2014-01-01

    Full Text Available This document presents the synthesis of different two-dimensional time-domain antenna arrays for steerable energy patterns with side lobe levels. The research is focused on the uniform and nonuniform distributions of true-time exciting delays and positions of antenna elements. The uniform square array, random array, uniform concentric ring array, and rotated nonuniform concentric ring array geometries are particularly studied. These geometries are synthesized by using the well-known sequential quadratic programming. The synthesis regards the optimal true-time exciting delays and optimal positions of pulsed antenna elements. The results show the capabilities of the different antenna arrays to steer the beam in their energy pattern in time domain and how their performance is in frequency domain after the synthesis in time domain.

  12. Bayesian reconstruction of P(r) directly from two-dimensional detector images via a Markov chain Monte Carlo method.

    Science.gov (United States)

    Paul, Sudeshna; Friedman, Alan M; Bailey-Kellogg, Chris; Craig, Bruce A

    2013-04-01

    The interatomic distance distribution, P(r), is a valuable tool for evaluating the structure of a molecule in solution and represents the maximum structural information that can be derived from solution scattering data without further assumptions. Most current instrumentation for scattering experiments (typically CCD detectors) generates a finely pixelated two-dimensional image. In contin-uation of the standard practice with earlier one-dimensional detectors, these images are typically reduced to a one-dimensional profile of scattering inten-sities, I(q), by circular averaging of the two-dimensional image. Indirect Fourier transformation methods are then used to reconstruct P(r) from I(q). Substantial advantages in data analysis, however, could be achieved by directly estimating the P(r) curve from the two-dimensional images. This article describes a Bayesian framework, using a Markov chain Monte Carlo method, for estimating the parameters of the indirect transform, and thus P(r), directly from the two-dimensional images. Using simulated detector images, it is demonstrated that this method yields P(r) curves nearly identical to the reference P(r). Furthermore, an approach for evaluating spatially correlated errors (such as those that arise from a detector point spread function) is evaluated. Accounting for these errors further improves the precision of the P(r) estimation. Experimental scattering data, where no ground truth reference P(r) is available, are used to demonstrate that this method yields a scattering and detector model that more closely reflects the two-dimensional data, as judged by smaller residuals in cross-validation, than P(r) obtained by indirect transformation of a one-dimensional profile. Finally, the method allows concurrent estimation of the beam center and Dmax, the longest interatomic distance in P(r), as part of the Bayesian Markov chain Monte Carlo method, reducing experimental effort and providing a well defined protocol for these

  13. Elastic Wave Scattering by Two-Dimensional Periodical Array of Cylinders

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    We extend the multiple-scattering theory (MST) for elastic wave scattering and propagating in two-dimensional composite. The formalism for the band structure calculation is presented by taking into account the full vector character of the elastic wave. As a demonstration of application of the formalism, we calculate the band structure of elastic wave propagating in a two-dimensional periodic arrangement of cylinders. The results manifest that the MST shows great promise in complementing the plane-wave (PW) approach for the study of elastic wave.

  14. Dynamics of two-dimensional vortex system in a strong square pinning array at the second matching field

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Qing-Bao [Department of Physics, Lishui University, Lishui 323000 (China); Luo, Meng-Bo, E-mail: Luomengbo@zju.edu.cn [Department of Physics, Zhejiang University, Hangzhou 310027 (China)

    2013-10-30

    We study the dynamics of a two-dimensional vortex system in a strong square pinning array at the second matching field. Two kinds of depinning behaviors, a continuous depinning transition at weak pinning and a discontinuous one at strong pinning, are found. We show that the two different kinds of vortex depinning transitions can be identified in transport as a function of the pinning strength and temperature. Moreover, interstitial vortex state can be probed from the transport properties of vortices.

  15. Light Focusing and Two-Dimensional Imaging Through Scattering Media using the Photoacoustic Transmission-Matrix with an Ultrasound Array

    CERN Document Server

    Chaigne, Thomas; Katz, Ori; Bossy, Emmanuel; Gigan, Sylvain

    2014-01-01

    We implement the photoacoustic transmission-matrix approach on a two-dimensional photoacoustic imaging system, using a 15 MHz linear ultrasound array. Using a black leaf skeleton as a complex absorbing structure, we demonstrate that the photoacoustic transmission-matrix approach allows to reveal structural features that are invisible in conventional photoacoustic images, as well as to selectively control light focusing on absorbing targets, leading to a local enhancement of the photoacoustic signal.

  16. Two-dimensional position-sensitive gaseous detectors for high-resolution neutron and X-ray diffraction

    CERN Document Server

    Marmotti, M; Kampmann, R

    2002-01-01

    Two-dimensional position-sensitive gaseous detectors have been developed at the Geesthacht Neutron Facility (GeNF) for high-resolution neutron and X-ray diffractometry. They are multi-wire proportional counters with delay-line readout and sensitive areas of 300 mm x 300 mm or 500 mm x 500 mm. For detecting X-rays, neutrons and hard X-rays the counters are filled with Ar/CO sub 2 , sup 3 He/CF sub 4 and Xe/CO sub 2 , respectively. One neutron detector is used at the ARES diffractometer at GKSS, which is dedicated to the analysis of residual stresses. Further ones are used for analysing textures and residual stresses at the hard-X-ray beamline PETRA-2 at HASYLAB, and one detector is being developed for the neutron reflectometer REFSANS at the research reactor FRM-II in Munich, Germany. (orig.)

  17. Aerosol assisted fabrication of two dimensional ZnO island arrays and honeycomb patterns with identical lattice structures

    Directory of Open Access Journals (Sweden)

    Mitsuhiro Numata

    2010-11-01

    Full Text Available Two dimensional island arrays and honeycomb patterns consisting of ZnO nanocrystal clusters were fabricated on predefined TiO2 seed patterns prepared by vacuum free, aerosol assisted wet-chemical synthesis. The TiO2 seed patterns were prepared by applying an aerosol of a water soluble titanium complex on hexagonally close-packed polystyrene bead arrays for different lengths of time. Scanning electron microscopy revealed that a dot array grows into a honeycomb shape as increasing amounts of the precursor were deposited. ZnO nucleation on substrates with a dot array and honeycomb patterns resulted in the formation of two discrete patterns with contrasting fill fractions of the materials.

  18. A PARALIND Decomposition-Based Coherent Two-Dimensional Direction of Arrival Estimation Algorithm for Acoustic Vector-Sensor Arrays

    Science.gov (United States)

    Zhang, Xiaofei; Zhou, Min; Li, Jianfeng

    2013-01-01

    In this paper, we combine the acoustic vector-sensor array parameter estimation problem with the parallel profiles with linear dependencies (PARALIND) model, which was originally applied to biology and chemistry. Exploiting the PARALIND decomposition approach, we propose a blind coherent two-dimensional direction of arrival (2D-DOA) estimation algorithm for arbitrarily spaced acoustic vector-sensor arrays subject to unknown locations. The proposed algorithm works well to achieve automatically paired azimuth and elevation angles for coherent and incoherent angle estimation of acoustic vector-sensor arrays, as well as the paired correlated matrix of the sources. Our algorithm, in contrast with conventional coherent angle estimation algorithms such as the forward backward spatial smoothing (FBSS) estimation of signal parameters via rotational invariance technique (ESPRIT) algorithm, not only has much better angle estimation performance, even for closely-spaced sources, but is also available for arbitrary arrays. Simulation results verify the effectiveness of our algorithm. PMID:23604030

  19. Defects detection in thin components using two-dimensional ultrasonic arrays

    Science.gov (United States)

    Velichko, A.; Wilcox, P. D.; Drinkwater, B. W.

    2013-01-01

    The use of 2D ultrasonic arrays provides great flexibility, as one array probe allows a given defect to be illuminated from a wide range of angles. However there are a number of challenges in the application of 2D arrays to detection and characterization of 3D defects. In the current paper the problem of finding the optimal array configuration for defects detection in thin sections is investigated. The efficient FE scattering model is used to simulate an ultrasonic array response for different 3D defects. The data provided by this model is then used to analyze the influence of different parameters on the array performance (signal to noise ratio, sensitivity, resolution). Finally, experimental results are shown that illustrate the imaging performance of optimal 2D array configuration.

  20. High-density flexible interconnect for two-dimensional ultrasound arrays.

    Science.gov (United States)

    Fiering, J O; Hultman, P; Lee, W; Light, E D; Smith, S W

    2000-01-01

    We present a method for fabricating flexible multilayer circuits for interconnection to 2-D array ultrasound transducers. In addition, we describe four 2-D arrays in which such flexible interconnect is implemented, including transthoracic arrays with 438 channels operating at up to 7 MHz and intracardiac catheter arrays with 70 channels operating at up to 7 MHz. We employ thin and thick film microfabrication techniques to batch produce the interconnect circuits with minimum dimensions of 12-mum lines, 40-mum vias, and 150-mum array pitch. The arrays show 50-Omega insertion loss of -60 to -84 dB and a fractional bandwidth of 27 to 67%. The arrays are used to obtain real time, in vivo volumetric scans.

  1. Two-dimensional catheter arrays for real-time intracardiac volumetric imaging

    Science.gov (United States)

    Light, Edward D.; Fiering, Jason O.; Lee, Warren; Wolf, Patrick D.; Smith, Stephen W.

    1999-06-01

    We have previously described 2D arrays of several thousand elements operating up to 5.0 MHz for transthoracic cardiac imaging. Lately, there has been interest in developing catheter based intracardiac imaging systems to aid in the precise tracking of anatomical features for improved diagnoses and therapies. We have constructed several arrays for real time intracardiac volumetric imaging based upon two different designs; a 10 X 10 equals 100 element 5.0 MHz forward looking 2D array, and a 13 X 11 equals 143 element 5.0 MHz 2D array for side scanning applications.

  2. Instrumentation for multi-detector arrays

    Indian Academy of Sciences (India)

    R K Bhowmik

    2001-07-01

    The new generation of detector arrays require complex instrumentation and data acquisition system to ensure increased reliability of operation, high degree of integration, software control and faster data handling capability. The main features of some of the existing multi-detector arrays like MSU 4 array, Gammasphere and Eurogam are summarized. The instrumentation for the proposed INGA array in India is discussed.

  3. Two-Dimensional Microdischarge Jet Array in Air: Characterization and Inactivation of Virus

    Science.gov (United States)

    Nayak, Gaurav

    Cold atmospheric pressure plasmas (CAPs) have proven to be quite effective for surface disinfection, wound healing and even cancer treatment in recent years. One of the major societal challenges faced today is related to illness caused by food-borne bacteria and viruses, particularly in minimally processed, fresh or ready-to-eat foods. Gastroenteritis outbreaks, caused, for example, by the human Norovirus (NV) is a growing concern. Current used technologies seem not to be fully effective. In this work we focus on a possible solution based on CAP technology for surface disinfection. Many discharge sources have been studied for disinfection and the two major challenges faced are the use of expensive noble gases (Ar/He) by many plasma sources and the difficulty to scale up the plasma devices. The efficacies of these devices also vary for different plasma sources, making it difficult to compare results from different research groups. Also, the interaction of plasma with the biological matter is not understood well, particularly for virus. In this work, a two-dimensional array of micro dielectric barrier discharge is used to treat Feline Calicivirus (FCV), which is a surrogate for human Norovirus. The plasma source can be operated with an air flow rate (up to 94 standard liters per minute or slm). The use of such discharge source also raises important scientific questions which are addressed in this work. These questions include the effect of gas flow rate on discharge properties and the production of reactive species responsible for virus inactivation and the underlying inactivation mechanism. The plasma source is characterized via several diagnostic techniques such as current voltage measurements for electrical characterization and power measurements, optical emission spectroscopy (OES) to determine the gas temperature, cross-correlation spectroscopy (CCS) for microdischarge evolution and timescales, UV absorption spectroscopy to measure the O3 density, absolute IR

  4. Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

    Science.gov (United States)

    Karasik, Boris S.; Gill, John J.; Mehdi, Imran; Crawford, Timothy J.; Sergeev, Andrei V.; Mitin, Vladimir V.

    2012-01-01

    High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

  5. Two-dimensional imaging detectors for structural biology with X-ray lasers.

    Science.gov (United States)

    Denes, Peter

    2014-07-17

    Our ability to harness the advances in microelectronics over the past decade(s) for X-ray detection has resulted in significant improvements in the state of the art. Biology with X-ray free-electron lasers present daunting detector challenges: all of the photons arrive at the same time, and individual high peak power pulses must be read out shot-by-shot. Direct X-ray detection in silicon pixel detectors--monolithic or hybrid--are the standard for XFELs today. For structural biology, improvements are needed for today's 10-100 Hz XFELs, and further improvements are required for tomorrow's 10+ kHz XFELs. This article will discuss detector challenges, why they arise and ways to overcome them, along with the current state of the art. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  6. Spectroscopic studies of the electronic properties of regularly arrayed two-dimensional protein layers

    Energy Technology Data Exchange (ETDEWEB)

    Vyalikh, D V [Institute of Solid State Physics, Dresden University of Technology, D-01062 Dresden (Germany); Kirchner, A [BioNanotechnology and Structure Formation Group, Max Bergmann Centre of Biomaterials, Dresden University of Technology, D-01062 Dresden (Germany); Kade, A [Institute of Solid State Physics, Dresden University of Technology, D-01062 Dresden (Germany); Danzenbaecher, S [Institute of Solid State Physics, Dresden University of Technology, D-01062 Dresden (Germany); Dedkov, Yu S [Institute of Solid State Physics, Dresden University of Technology, D-01062 Dresden (Germany); Mertig, M [BioNanotechnology and Structure Formation Group, Max Bergmann Centre of Biomaterials, Dresden University of Technology, D-01062 Dresden (Germany); Molodtsov, S L [Institute of Solid State Physics, Dresden University of Technology, D-01062 Dresden (Germany)

    2006-04-05

    Photoemission (PE) and near-edge x-ray absorption fine structure (NEXAFS) spectroscopy were applied to characterize electronic properties of the regular two-dimensional bacterial surface protein layer (S layer) of Bacillus sphaericus NCTC 9602, which is widely used as a protein template for the bottom-up fabrication of advanced metallic and hybrid nanostructures. PE and NEXAFS at the C 1s, O 1s, and N 1s core levels show similar chemical states for each oxygen atom and also for each nitrogen atom, while carbon atoms exhibit a range of chemical environments in different functional groups of the amino acids. A series of characteristic NEXAFS peaks were assigned to particular molecular orbitals of the amino acids by applying a phenomenological building-block model. It was found that the {pi} clouds of aromatic rings make the main contribution to both the lowest unoccupied and highest occupied molecular orbitals. The two-dimensional protein crystal shows a semiconductor-like behaviour with a gap value of {approx}3.0 eV and the Fermi energy close to the bottom of the LUMO.

  7. Universal and discriminative detection using a miniaturized pulsed discharge detector in comprehensive two-dimensional GC.

    Science.gov (United States)

    Winniford, Bill L; Sun, Kefu; Griffith, James F; Luong, Jim C

    2006-11-01

    A miniaturized pulsed discharge detector (Mini-PDD) has been successfully demonstrated for comprehensive 2-D GC (GC x GC) analysis of pyrolysis gasoline and the pyrolysis GC x GC analysis of a polyethylene copolymer. The detector cell volume of the Mini-PDD is reduced to 25% of the Valco plug-in PDD D-3. An n-C11 peak width at base is 96 ms for the Mini-PDD, about 23% larger than a peak width of 78 ms detected by a flame ionization detector (FID). The Mini-PDD has sufficient response time for most GC x GC applications. When Mini-PDD is operated in helium photoionization mode (Mini He-PDD), it is a universal detector for both inorganic and organic compounds. This is especially useful when detection of water is needed in GC x GC applications. When krypton is doped in the helium discharge gas (Mini Kr-PDD), it can suppress signals of compounds having higher ionization potentials and enhance relative signal intensities of aromatic compounds. The determination of aliphatic to aromatic hydrocarbon ratios is essential to the operation of petroleum crackers. Comparison of the signal from two modes of the Mini-PDD is a simple and fast way to verify the location of aromatics in comprehensive 2-D gas chromatograms.

  8. Deterministic strain-induced arrays of quantum emitters in a two-dimensional semiconductor

    Science.gov (United States)

    Branny, Artur; Kumar, Santosh; Proux, Raphaël; Gerardot, Brian D

    2017-01-01

    An outstanding challenge in quantum photonics is scalability, which requires positioning of single quantum emitters in a deterministic fashion. Site positioning progress has been made in established platforms including defects in diamond and self-assembled quantum dots, albeit often with compromised coherence and optical quality. The emergence of single quantum emitters in layered transition metal dichalcogenide semiconductors offers new opportunities to construct a scalable quantum architecture. Here, using nanoscale strain engineering, we deterministically achieve a two-dimensional lattice of quantum emitters in an atomically thin semiconductor. We create point-like strain perturbations in mono- and bi-layer WSe2 which locally modify the band-gap, leading to efficient funnelling of excitons towards isolated strain-tuned quantum emitters that exhibit high-purity single photon emission. We achieve near unity emitter creation probability and a mean positioning accuracy of 120±32 nm, which may be improved with further optimization of the nanopillar dimensions. PMID:28530219

  9. Deterministic strain-induced arrays of quantum emitters in a two-dimensional semiconductor

    Science.gov (United States)

    Branny, Artur; Kumar, Santosh; Proux, Raphaël; Gerardot, Brian D.

    2017-05-01

    An outstanding challenge in quantum photonics is scalability, which requires positioning of single quantum emitters in a deterministic fashion. Site positioning progress has been made in established platforms including defects in diamond and self-assembled quantum dots, albeit often with compromised coherence and optical quality. The emergence of single quantum emitters in layered transition metal dichalcogenide semiconductors offers new opportunities to construct a scalable quantum architecture. Here, using nanoscale strain engineering, we deterministically achieve a two-dimensional lattice of quantum emitters in an atomically thin semiconductor. We create point-like strain perturbations in mono- and bi-layer WSe2 which locally modify the band-gap, leading to efficient funnelling of excitons towards isolated strain-tuned quantum emitters that exhibit high-purity single photon emission. We achieve near unity emitter creation probability and a mean positioning accuracy of 120+/-32 nm, which may be improved with further optimization of the nanopillar dimensions.

  10. Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

    Energy Technology Data Exchange (ETDEWEB)

    Ferhanoglu, Onur; Urey, Hakan

    2011-07-01

    Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

  11. Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout.

    Science.gov (United States)

    Ferhanoglu, Onur; Urey, Hakan

    2011-07-01

    Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-λ) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization (~20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. ~30% increase in the average sensitivity was demonstrated for a 160×120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

  12. Two-dimensional GEM imaging detector with delay-line readout

    Science.gov (United States)

    Guedes, G. P.; Breskin, A.; Chechik, R.; Vartsky, D.; Bar, D.; Barbosa, A. F.; Marinho, P. R. B.

    2003-11-01

    A 100×100 mm 2 2D imaging detector, based on a triple-GEM gaseous multiplier, striped x- y readout anode and discrete delay-line readout, is presented. The fast (2.1 ns tap -1) delay-line circuit was designed to match the anode-charge signal profile, namely its rise-time and length. The detector's imaging capability was systematically studied in Ar/CO 2 (70/30) with 5.9 keV X-rays; x- y resolution of σ=0.05 and 0.1 mm for top and bottom anode strips, respectively, and integral non-linearity of ˜0.15% are demonstrated.

  13. Two-dimensional position-sensitive detectors for small-angle neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    McElhaney, S.A.; Vandermolen, R.I.

    1990-05-01

    In this paper, various detectors available for small angle neutron scattering (SANS) are discussed, along with some current developments being actively pursued. A section has been included to outline the various methodologies of position encoding/decoding with discussions on trends and limitations. Computer software/hardware vary greatly from institute and experiment and only a general discussion is given to this area. 85 refs., 33 figs.

  14. Accurate two-dimensional model of an arrayed-waveguide grating demultiplexer and optimal design based on the reciprocity theory.

    Science.gov (United States)

    Dai, Daoxin; He, Sailing

    2004-12-01

    An accurate two-dimensional (2D) model is introduced for the simulation of an arrayed-waveguide grating (AWG) demultiplexer by integrating the field distribution along the vertical direction. The equivalent 2D model has almost the same accuracy as the original three-dimensional model and is more accurate for the AWG considered here than the conventional 2D model based on the effective-index method. To further improve the computational efficiency, the reciprocity theory is applied to the optimal design of a flat-top AWG demultiplexer with a special input structure.

  15. Fabrication of Two-Dimensional Arrays of Micron-Sized Gold Rings Based on Preferential Nucleation at Reentrant Sites

    Institute of Scientific and Technical Information of China (English)

    DONG Wen; GUO Xiang; WANG Si-Zhen; WANG Zhen-Lin; MING Nai-Ben

    2008-01-01

    @@ A templating method for fabricating two-dimensional (2D) arrays of micron-sized gold rings is reported. The microstructures are formed by electroless plating in a through-porous polymer membrane on a silicon substrate obtained from a closed-packed silica colloidal crystal. Our results show that the sizes of gold rings can be altered by varying electroless plating conditions for the porous polystyrene membranes. Moreover, we explain the growth mechanism of gold rings using the classical crystal growth theory that is preferential nucleation at reentrant sites.

  16. Optical characterization of two-dimensional array of 2,048 tilting micromirrors for astronomical spectroscopy.

    Science.gov (United States)

    Canonica, Michael D; Zamkotsian, Frédéric; Lanzoni, Patrick; Noell, Wilfried; De Rooij, Nico

    2013-09-23

    A micromirror array composed of 2048 silicon micromirrors measuring 200 × 100 μm² and tilting by 25° was developed as a reconfigurable slit mask for multi-object spectroscopy (MOS) in astronomy. The fill factor, contrast, and mirror deformation at both room and cryogenic temperatures were investigated. Contrast was measured using an optical setup that mimics a MOS instrument, and mirror deformation was characterized using a Twyman-Green interferometer. The results indicate that the array exhibited a fill factor of 82%, a contrast ratio of 1000:1, and surface mirror deformations of 8 nm and 27 nm for mirrors tilted at 298 K and 162 K, respectively.

  17. Detailed compositional characterization of plastic waste pyrolysis oil by comprehensive two-dimensional gas-chromatography coupled to multiple detectors.

    Science.gov (United States)

    Toraman, Hilal E; Dijkmans, Thomas; Djokic, Marko R; Van Geem, Kevin M; Marin, Guy B

    2014-09-12

    The detailed compositional characterization of plastic waste pyrolysis oil was performed with comprehensive two-dimensional GC (GC×GC) coupled to four different detectors: a flame ionization detector (FID), a sulfur chemiluminescence detector (SCD), a nitrogen chemiluminescence detector (NCD) and a time of flight mass spectrometer (TOF-MS). The performances of different column combinations were assessed in normal i.e. apolar/mid-polar and reversed configurations for the GC×GC-NCD and GC×GC-SCD analyses. The information obtained from the four detectors and the use of internal standards, i.e. 3-chlorothiophene for the FID and the SCD and 2-chloropyridine for the NCD analysis, enabled the identification and quantification of the pyrolysis oil in terms of both group type and carbon number: hydrocarbon groups (n-paraffins, iso-paraffins, olefins and naphthenes, monoaromatics, naphthenoaromatics, diaromatics, naphthenodiaromatics, triaromatics, naphthenotriaromatics and tetra-aromatics), nitrogen (nitriles, pyridines, quinolines, indole, caprolactam, etc.), sulfur (thiols/sulfides, thiophenes/disulfides, benzothiophenes, dibenzothiophenes, etc.) and oxygen containing compounds (ketones, phenols, aldehydes, ethers, etc.). Quantification of trace impurities is illustrated for indole and caprolactam. The analyzed pyrolysis oil included a significant amount of nitrogen containing compounds (6.4wt%) and to a lesser extent sulfur containing compounds (0.6wt%). These nitrogen and sulfur containing compounds described approximately 80% of the total peak volume for respectively the NCD and SCD analysis. TOF-MS indicated the presence of the oxygen containing compounds. However only a part of the oxygen containing compounds (2.5wt%) was identified because of their low concentrations and possible overlap with the complex hydrocarbon matrix as no selective detector or preparative separation for oxygen compounds was used.

  18. Two-dimensional array of microtraps with atomic shift register on a chip

    NARCIS (Netherlands)

    Whitlock, S.; Gerritsma, R.; Fernholz, T.; Spreeuw, R.J.C.

    2009-01-01

    Arrays of trapped atoms are the ideal starting points for developing registers comprising large numbers of physical qubits for storing and processing quantum information. One very promising approach involves neutral atom traps produced on microfabricated devices known as atom chips, as almost

  19. Modeling and optimization of non-phased two-dimensional ultrasonic arrays

    Science.gov (United States)

    Denisov, Alexey A.

    Ultrasonic image acquisition with non-phased 2D arrays is a relatively new method in NDE inspection. Historically, ultrasonic array development progressed mostly in the medical imaging where phased arrays found a great application. However, in the field of NDE inspection of metals, heavy plastics and composites, and many other materials the applicability of phased arrays is often restricted due to physical limitations. On the other hand, using versatile systems with mechanical scanning is not always convenient. Therefore, non-phased arrays of independent elements have a strong potential for becoming a valuable tool for rapid ultrasonic image acquisition in the industrial environment as well as in many other areas where conventional methods may not be applicable. The main motivation of this work is to build the necessary mathematical apparatus for estimating the process of signal and image formation in such systems. A model of signal penetration through a complex multilayered structure with non-parallel interfaces is discussed in the plane-wave approximation. This model is then refined to finite-size transducers and finite-size defects inside the sample. A new method of obtaining the beam structure in such multi-layered media is presented. The advantage of this method is that it allows for a very fast calculation while the precision is still comparable to more precise and more computationally expensive methods. A new method of calculating the response of the transducer to defects inside the sample is presented and discussed. The results of numerical calculations using these two methods are discussed and compared with experimental data. Using these models, image formation algorithms together with new image refining techniques are discussed.

  20. Aluminum-based one- and two-dimensional micro fin array structures: high-throughput fabrication and heat transfer testing

    Science.gov (United States)

    Primeaux, Philip A.; Zhang, Bin; Zhang, Xiaoman; Miller, Jacob; Meng, W. J.; KC, Pratik; Moore, Arden L.

    2017-02-01

    Microscale fin array structures were replicated onto surfaces of aluminum 1100 and aluminum 6061 alloy (Al1100/Al6061) sheet metals through room-temperature instrumented roll molding. Aluminum-based micro fin arrays were replicated at room temperature, and the fabrication process is one with high throughput and low cost. One-dimensional (1D) micro fin arrays were made through one-pass rolling, while two-dimensional (2D) micro fin arrays were made by sequential 90° cross rolling with the same roller sleeve. For roll molding of 1D micro fins, fin heights greater than 600 µm were achieved and were shown to be proportional to the normal load force per feature width. At a given normal load force, the fin height was further shown to scale inversely with the hardness of the sheet metal. For sequential 90° cross rolling, morphologies of roll molded 2D micro fin arrays were examined, which provided clues to understand how plastic deformation occurred under cross rolling conditions. A series of pool boiling experiments on low profile Al micro fin array structures were performed within Novec 7100, a widely used commercial dielectric coolant. Results for both horizontal and vertical surface orientations show that roll molded Al micro fin arrays can increase heat flux at fixed surface temperature as compared to un-patterned Al sheet. The present results further suggest that many factors beyond just increased surface area can influence heat transfer performance, including surface finish and the important multiphase transport mechanisms in and around the fin geometry. These factors must also be considered when designing and optimizing micro fin array structures for heat transfer applications.

  1. Two dimensional, electronic particle tracking in liquids with a graphene-based magnetic sensor array

    Science.gov (United States)

    Neumann, Rodrigo F.; Engel, Michael; Steiner, Mathias

    2016-07-01

    The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual nanoparticles in the liquid with high accuracy and (b) the reconstruction of a particle's flow-driven trajectory across the integrated sensor array with sub-pixel precision as a function of time, in what we call the ``Magnetic nanoparticle velocimetry'' technique. Since the method does not rely on optical detection, potential lab-on-chip applications include particle tracking and flow analysis in opaque media at the sub-micron scale.The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual

  2. Two-dimensional Fast ESPRIT Algorithm for Linear Array SAR Imaging

    Directory of Open Access Journals (Sweden)

    Zhao Yi-chao

    2015-10-01

    Full Text Available The linear array Synthetic Aperture Radar (SAR system is a popular research tool, because it can realize three-dimensional imaging. However, owning to limitations of the aircraft platform and actual conditions, resolution improvement is difficult in cross-track and along-track directions. In this study, a twodimensional fast Estimation of Signal Parameters by Rotational Invariance Technique (ESPRIT algorithm for linear array SAR imaging is proposed to overcome these limitations. This approach combines the Gerschgorin disks method and the ESPRIT algorithm to estimate the positions of scatterers in cross and along-rack directions. Moreover, the reflectivity of scatterers is obtained by a modified pairing method based on “region growing”, replacing the least-squares method. The simulation results demonstrate the applicability of the algorithm with high resolution, quick calculation, and good real-time response.

  3. Two-dimensional analytic modeling of acoustic diffraction for ultrasonic beam steering by phased array transducers.

    Science.gov (United States)

    Wang, Tiansi; Zhang, Chong; Aleksov, Aleksandar; Salama, Islam; Kar, Aravinda

    2017-04-01

    Phased array ultrasonic transducers enable modulating the focal position of the acoustic waves, and this capability is utilized in many applications, such as medical imaging and non-destructive testing. This type of transducers also provides a mechanism to generate tilted wavefronts in acousto-optic deflectors to deflect laser beams for high precision advanced laser material processing. In this paper, a theoretical model is presented for the diffraction of ultrasonic waves emitted by several phased array transducers into an acousto-optic medium such as TeO2 crystal. A simple analytic expression is obtained for the distribution of the ultrasonic displacement field in the crystal. The model prediction is found to be in good agreement with the results of a numerical model that is based on a non-paraxial multi-Gaussian beam (NMGB) model.

  4. Structured mirror array for two-dimensional collimation of a chromium beam in atom lithography

    Institute of Scientific and Technical Information of China (English)

    Zhang Wan-Jing; Ma Yan; Li Tong-Bao; Zhang Ping-Ping; Deng Xiao; Chen Sheng; Xiao Sheng-Wei

    2013-01-01

    Direct-write atom lithography,one of the potential nanofabrication techniques,is restricted by some difficulties in producing optical masks for the deposition of complex structures.In order to make further progress,a structured mirror array is developed to transversely collimate the chromium atomic beam in two dimensions.The best collimation is obtained when the laser red detunes by natural line-width of transition 7S3 → 7P40 of the chromium atom.The collimation ratio is 0.45 vertically (in x axis),and it is 0.55 horizontally (in y axis).The theoretical model is also simulated,and success of our structured mirror array is achieved.

  5. Rational design of two-dimensional molecular donor-acceptor nanostructure arrays

    Science.gov (United States)

    Zhang, Jia Lin; Zhong, Shu; Zhong, Jian Qiang; Niu, Tian Chao; Hu, Wen Ping; Wee, Andrew Thye Shen; Chen, Wei

    2015-02-01

    The construction of long-range ordered organic donor-acceptor nanostructure arrays over microscopic areas supported on solid substrates is one of the most challenging tasks towards the realization of molecular nanodevices. They can also be used as ideal model systems to understand light induced charge transfer, charge separation and energy conversion processes and mechanisms at the nanometer scale. The aim of this paper is to highlight recent advances and progress in this topic. Special attention is given to two different strategies for the construction of organic donor-acceptor nanostructure arrays, namely (i) molecular self-assembly on artificially patterned or pre-defined molecular surface nanotemplates and (ii) molecular nanostructure formation steered via directional and selective intermolecular interactions. The interfacial charge transfer and the energy level alignment of these donor-acceptor nanostructures are also discussed.

  6. Acoustic band gaps in two-dimensional square arrays of semi-hollow circular cylinders

    Institute of Scientific and Technical Information of China (English)

    T.; Kim

    2009-01-01

    Concave surfaces focus sound while convex surfaces disperse sound. It is therefore interesting to know if it is possible to make use of these two opposite characteristics to enhance the band gap performance of periodic arrays of solid cylinders in air. In this paper, the band gap characteristics of a 2-D square array of semi-hollow circular cylinders embedded in air are investigated, both experimentally and theoretically. In comparison with the types of inclusion studied by previous researchers, a semi-hollow circular cylinder is unique in the sense that it has concave inner surfaces and convex outer surfaces. The finite difference time domain (FDTD) method is employed to study the propagation behavior of sound across the new phononic crystal of finite extent, and the influences of sample size and inclusion orientation on band gap characteristics are quantified in order to obtain the maximum band gap. For reference, the band gap behaviors of solid circular cylinder/air and hollow circular cylinder/air systems are considered and compared with those of semi-hollow circular cylinder/air systems. In addition to semi-hollow circular cylinders, other inclusion topologies such as semi-hollow triangular and square cylinders are also investigated. To validate the theoretical predictions, experimental measurements on square arrays of hollow Al cylinders in air and semi-hollow Al cylinders in air are carried out. The results demonstrate that the semi-hollow circular cylinder/air system has the best overall band gap performance.

  7. Two dimensional, electronic particle tracking in liquids with a graphene-based magnetic sensor array.

    Science.gov (United States)

    Neumann, Rodrigo F; Engel, Michael; Steiner, Mathias

    2016-07-14

    The investigation and control of liquid flow at the nanometer scale is a key area of applied research with high relevance to physics, chemistry, and biology. We introduce a method and a device that allows the spatial resolution of liquid flow by integrating an array of graphene-based magnetic (Hall) sensors that is used for tracking the movement of magnetic nanoparticles immersed in a liquid under investigation. With a novel device concept based on standard integration processes and experimentally verified material parameters, we numerically simulate the performance of a single sensor pixel, as well as the whole sensor array, for tracking magnetic nanoparticles having typical properties. The results demonstrate that the device enables (a) the detection of individual nanoparticles in the liquid with high accuracy and (b) the reconstruction of a particle's flow-driven trajectory across the integrated sensor array with sub-pixel precision as a function of time, in what we call the "Magnetic nanoparticle velocimetry" technique. Since the method does not rely on optical detection, potential lab-on-chip applications include particle tracking and flow analysis in opaque media at the sub-micron scale.

  8. A direct time measurements technique for the two-dimensional precision coordinate detectors based on thin-walled drift tubes

    CERN Document Server

    Makankin, A M; Peshekhonov, V D; Ritt, S; Vasilyev, S E

    2013-01-01

    This article presents the results of a study of the longitudinal spatial resolution of 2 m long straw tubes by means of the direct timing method (DTM). The feasibility of achieving a coordinate resolution (r.m.s.) better than 2 cm over full length of the straw is demonstrated. The spatial resolution insignificantly changes when measured by detecting gammas from a Fe-55 gamma ray source or minimum ionizing particles from a Ru-106 source. The use of the same type of FEE for data taking both for measuring the drift time of ionization electrons and propagation of a signal along the anode wire allows one to construct a two-dimensional detector for precision coordinate measurements.

  9. A direct time measurement technique for the two-dimensional precision coordinate detectors based on thin-walled drift tubes

    Energy Technology Data Exchange (ETDEWEB)

    Makankin, A.M.; Myalkovskiy, V.V. [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation); Peshekhonov, V.D., E-mail: Vladimir.Peshekhonov@sunse.jinr.ru [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation); Ritt, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Vasilyev, S.E. [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation)

    2014-01-21

    This article presents the results of a study of the longitudinal spatial resolution by means of the direct timing method (DTM) using 2 m long and 9.53 mm diameter straw tubes. The feasibility of achieving the spatial resolution (r.m.s.) better than 2 cm over full length of the straw is demonstrated. The spatial resolution changes little when measured by detecting gammas from a Fe-55 gamma ray source or minimum ionizing electrons from a Ru-106 source. The use of the same type of front end electronics (FEE) both for measuring the drift time of ionization electrons and propagation time of a signal along the anode wire allows one to construct a detector capable for measuring the two dimensional coordinates of charged particles.

  10. Acoustic band gaps in two-dimensional square arrays of semi-hollow circular cylinders

    Institute of Scientific and Technical Information of China (English)

    LU TianJian; GAO GuoQin; MA ShouLin; JIN Feng; T.Kim

    2009-01-01

    Concave surfaces focus sound while convex surfaces disperse sound. It is therefore interesting to know if it is possible to make use of these two opposite characteristics to enhance the band gap per-formance of periodic arrays of solid cylinders in air. In this paper, the band gap characteristics of a 2-D square array of semi-hollow circular cylinders embedded in air are investigated, both experimentally and theoretically. In comparison with the types of inclusion studied by previous researchers, a semi-hollow circular cylinder is unique in the sense that it has concave inner surfaces and convex outer surfaces. The finite difference time domain (FDTD) method is employed to study the propagation behavior of sound across the new phononic crystal of finite extent, and the influences of sample size and inclusion orientation on band gap characteristics are quantified in order to obtain the maximum band gap. For reference, the band gap behaviors of solid circular cylinder/air and hollow circular cyl-inder/air systems are considered and compared with those of semi-hollow circular cylinder/air systems. In addition to semi-hollow circular cylinders, other inclusion topologies such as semi-hollow triangular and square cylinders are also investigated. To validate the theoretical predictions, experimental meas-urements on square arrays of hollow AI cylinders in air and semi-hollow AI cylinders in air are carried out. The results demonstrate that the semi-hollow circular cylinder/air system has the best overall band gap performance.

  11. Two-dimensional spin liquids with Z2 topological order in an array of quantum wires

    Science.gov (United States)

    Patel, Aavishkar A.; Chowdhury, Debanjan

    2016-11-01

    Insulating Z2 spin liquids are a phase of matter with bulk anyonic quasiparticle excitations and ground-state degeneracies on manifolds with nontrivial topology. We construct a time-reversal symmetric Z2 spin liquid in two spatial dimensions using an array of quantum wires. We identify the anyons as kinks in the appropriate Luttinger-liquid description, compute their mutual statistics, and construct local operators that transport these quasiparticles. We also present a construction of a fractionalized Fermi liquid (FL*) by coupling the spin sector of the Z2 spin liquid to a Fermi liquid via a Kondo-like coupling.

  12. Magnetic field induced phase branches of the superconducting transition in two-dimensional square Π-loop arrays

    Institute of Scientific and Technical Information of China (English)

    Liu Dang-Ting; Tian Ye; Chen Geng-Hua; Yang Qian-Sheng

    2008-01-01

    Based on the results of explicit forms of free energy density for each possible arrangement of magnetization fluxes in large-scale two-dimensional (2D) square Π-loop arrays given by Li et al [2007 Chin.Phys.16 1450],the field-cooled superconducting phase transition is further investigated by analysing the free energy of the arrays with a simplified symmetrical model.Our analytical result is exactly the same as that obtained in Li's paper by means of numerical calculations.It is shown that the phase transition splits into two branches with either ferromagnetic or anti-ferromagnetic flux ordering,which depends periodically on the strength of external magnetic flux φe through each loop and monotonically on the screen parameter β of the loops in the arrays.In principle,the diagram of the phase branches is similar to that of its one-dimensional counterpart.The influence of thermal fluctuation on the flux ordering during the transition from normal to superconducting states of the Π-loop arrays is also discussed.

  13. Efficient Two-Dimensional Direction Finding via Auxiliary-Variable Manifold Separation Technique for Arbitrary Array Structure

    Directory of Open Access Journals (Sweden)

    Guang Hua

    2015-01-01

    Full Text Available A polynomial rooting direction of arrival (DOA algorithm for multiple plane waves incident on an arbitrary array structure that combines the multipolynomial resultants and matrix computations is proposed in this paper. Firstly, a new auxiliary-variable manifold separation technique (AV-MST is used to model the steering vector of arbitrary array structure as the product of a sampling matrix (dependent only on the array structure and two Vandermonde-structured wavefield coefficient vectors (dependent on the wavefield. Then the propagator operator is calculated and used to form a system of bivariate polynomial equations. Finally, the automatically paired azimuth and elevation estimates are derived by polynomial rooting. The presented algorithm employs the concept of auxiliary-variable manifold separation technique which requires no sector by sector array interpolation and thus does not suffer from any mapping errors. In addition, the new algorithm does not need any eigenvalue decomposition of the covariance matrix and exhausted search over the two-dimensional parameter space. Moreover, the algorithm gives automatically paired estimates, thus avoiding the complex pairing procedure. Therefore, the proposed algorithm shows low computational complexity and high robustness performance. Simulation results are shown to validate the effectiveness of the proposed method.

  14. Self-Assembled Two-Dimensional Array of Gold Nanoparticles with Different Size for the Sensing Application

    Science.gov (United States)

    Li, Wan-Chao; Park, Sang-Eun; Kim, Jongsung; Lee, Sang-Wha

    2009-06-01

    Self-assembled two-dimensional array of gold nanoparticles (GNPs) on the glass substrate was systematically investigated in terms of glass cleaning, K2CO3 addition, GNP size, and pH of gold colloids. An ambient-air plasma treatment produced a highly-activated glass surface with the lowest air/water contact angles and K2CO3 addition is very effective to preserve the optical properties of gold nanoparticles for a long time. Small GNPs (≤40 nm) was uniformly arrayed on the amine-functionalized glass through the optimization process of electrostatic attractions between positively-charged glass and negatively-charged gold nanoparticles. For large GNPs (≥50 nm) that resulted in discrete (or loosely-packed) array on the glass substrate, pH adjustment of gold colloids (from pH 11 to 9) produced more densely-packed array of GNPs with less void areas, probably due to the reduction of electrostatic repulsion forces between large gold nanoparticles.

  15. Growth of two-dimensional arrays of uncapped gold nanoparticles on silicon substrates

    Indian Academy of Sciences (India)

    Anindya Das; Soma Das; A K Raychaudhuri

    2008-06-01

    A method of preparing large area patterned 2D arrays of uncapped gold (Au) nanoparticles has been developed. The pattern has been formed using self-assembly of uncapped Au nanoparticles. The Au nanoparticles were synthesized via toluene/water two phase systems using a reducing agent and colloidal solution of Au nanoparticles was produced. These nanoparticles have been prepared without using any kind of capping agent. Analysis by TEM showed discrete Au nanoparticles of 4 nm average diameter. AFM analysis also showed similar result. The TEM studies showed that these nanoparticles formed self-assembled coherent patterns with dimensions exceeding 500 nm. Spin coating on silicon substrate by suitably adjusting the speed can self-assemble these nanoparticles to lengths exceeding 1 m.

  16. A Study on Group Key Agreement in Sensor Network Environments Using Two-Dimensional Arrays

    Directory of Open Access Journals (Sweden)

    Moon-Seog Jun

    2011-08-01

    Full Text Available These days, with the emergence of the concept of ubiquitous computing, sensor networks that collect, analyze and process all the information through the sensors have become of huge interest. However, sensor network technology fundamentally has wireless communication infrastructure as its foundation and thus has security weakness and limitations such as low computing capacity, power supply limitations and price. In this paper, and considering the characteristics of the sensor network environment, we propose a group key agreement method using a keyset pre-distribution of two-dimension arrays that should minimize the exposure of key and personal information. The key collision problems are resolved by utilizing a polygonal shape’s center of gravity. The method shows that calculating a polygonal shape’s center of gravity only requires a very small amount of calculations from the users. The simple calculation not only increases the group key generation efficiency, but also enhances the sense of security by protecting information between nodes.

  17. Monitoring of high-intensity focused ultrasound treatment by shear wave elastography induced by two-dimensional-array therapeutic transducer

    Science.gov (United States)

    Iwasaki, Ryosuke; Takagi, Ryo; Nagaoka, Ryo; Jimbo, Hayato; Yoshizawa, Shin; Saijo, Yoshifumi; Umemura, Shin-ichiro

    2016-07-01

    Shear wave elastography (SWE) is expected to be a noninvasive monitoring method of high-intensity focused ultrasound (HIFU) treatment. However, conventional SWE techniques encounter difficulty in inducing shear waves with adequate displacements in deep tissue. To observe tissue coagulation at the HIFU focal depth via SWE, in this study, we propose using a two-dimensional-array therapeutic transducer for not only HIFU exposure but also creating shear sources. The results show that the reconstructed shear wave velocity maps detected the coagulated regions as the area of increased propagation velocity even in deep tissue. This suggests that “HIFU-push” shear elastography is a promising solution for the purpose of coagulation monitoring in deep tissue, because push beams irradiated by the HIFU transducer can naturally reach as deep as the tissue to be coagulated by the same transducer.

  18. Single-exposure two-dimensional superresolution in digital holography using a vertical cavity surface-emitting laser source array.

    Science.gov (United States)

    Granero, Luis; Zalevsky, Zeev; Micó, Vicente

    2011-04-01

    We present a new implementation capable of producing two-dimensional (2D) superresolution (SR) imaging in a single exposure by aperture synthesis in digital lensless Fourier holography when using angular multiplexing provided by a vertical cavity surface-emitting laser source array. The system performs the recording in a single CCD snapshot of a multiplexed hologram coming from the incoherent addition of multiple subholograms, where each contains information about a different 2D spatial frequency band of the object's spectrum. Thus, a set of nonoverlapping bandpass images of the input object can be recovered by Fourier transformation (FT) of the multiplexed hologram. The SR is obtained by coherent addition of the information contained in each bandpass image while generating an enlarged synthetic aperture. Experimental results demonstrate improvement in resolution and image quality.

  19. A fast adaptive convex hull algorithm on two-dimensional processor arrays with a reconfigurable BUS system

    Science.gov (United States)

    Olariu, S.; Schwing, J.; Zhang, J.

    1991-01-01

    A bus system that can change dynamically to suit computational needs is referred to as reconfigurable. We present a fast adaptive convex hull algorithm on a two-dimensional processor array with a reconfigurable bus system (2-D PARBS, for short). Specifically, we show that computing the convex hull of a planar set of n points taken O(log n/log m) time on a 2-D PARBS of size mn x n with 3 less than or equal to m less than or equal to n. Our result implies that the convex hull of n points in the plane can be computed in O(1) time in a 2-D PARBS of size n(exp 1.5) x n.

  20. Fast transport, atom sample splitting, and single-atom qubit supply in two-dimensional arrays of optical microtraps

    CERN Document Server

    Schlosser, Malte; Gierl, Christian; Teichmann, Stephan; Tichelmann, Sascha; Birkl, Gerhard; 10.1088/1367-2630/14/12/123034

    2013-01-01

    Two-dimensional arrays of optical micro-traps created by microoptical elements present a versatile and scalable architecture for neutral atom quantum information processing, quantum simulation, and the manipulation of ultra-cold quantum gases. In this article, we demonstrate advanced capabilities of this approach by introducing novel techniques and functionalities as well as the combined operation of previously separately implemented functions. We introduce piezo-actuator based transport of atom ensembles over distances of more than one trap separation, examine the capabilities of rapid atom transport provided by acousto-optical beam steering, and analyze the adiabaticity limit for atom transport in these configurations. We implement a spatial light modulator with 8-bit transmission control for the per-site adjustment of the trap depth and the number of atoms loaded. We combine single-site addressing, trap depth control, and atom transport in one configuration for demonstrating the splitting of atom ensembles...

  1. Investigation of polarization-selective InGaAs sensor with elliptical two-dimensional holes array structure

    Science.gov (United States)

    Wang, Wenbo; Fu, Dong; Hu, Xiaobin; Xu, Yun; Song, Guofeng; Wei, Xin

    2016-10-01

    Polarimetric imaging in infrared wavelengths have attracted more and more attention for broad applications in meteorological observations, medicine, remote sensing and many other fields. Metal metamaterial structures are used in nanophotonics in order to localize and enhance the incident electromagnetic field. Here we develop an elliptical gold Two-Dimensional Holes Array (2DHA) in which photons can be manipulated by surface plasmon resonance, and the ellipse introduce the asymmetry to realize a polarization selective function. Strong polarization dependence is observed in the simulated transmission spectra. To further understand the coupling mechanism between gold holes array and InP, the different parameters of the 2DHA are analyzed. It is shown that the polarization axis is perpendicular to the major axis of the ellipse, and the degree of polarization is determined by the aspect ratio of the ellipse. Furthermore, the resonance frequency of the 2DHA shows a linear dependence on the array period, the bandwidth of transmission spectra closely related to duty cycle of the ellipse in each period. This result will establish a basis for the development of innovative polarization selective infrared sensor.

  2. One- and Two-Dimensional Arrays of Double-Well Optical Traps for Cold Atoms or Molecules

    Institute of Scientific and Technical Information of China (English)

    JI Xian-Ming; YIN Jian-Ping

    2004-01-01

    @@ We propose a novel scheme to form one- and two-dimensional arrays of double-well optical dipole traps for cold atoms (or molecules) by using an optical system composed of a binary π-phase grating and a lens illuminated by a plane light wave, and study the relationship between the maximum intensity Imax of each optical well (or the maximum trapping potential Umax for 85Rb atoms) and the relative apertureβ (= a/f) of the lens. We also calculate the intensity gradients of each optical well and their curvatures, and estimate the spontaneous photon-scattering rate of trapped atom in each well, including Rayleigh and Raman scattering rates. Our study shows that the proposed 1D and 2D arrays of double-well traps can be used to prepare 1D and 2D novel optical lattices with cold atoms (or molecules), or form an all-optically integrated atom optical chip, or even to realize an array of all-optical double-well atomic (or molecular) Bose-Einstein condensates by optical-potential evaporative cooling, and so on.

  3. Si:As BIB detector arrays

    Science.gov (United States)

    Bharat, R.; Petroff, M. D.; Speer, J. J.; Stapelbroek, M. G.

    1986-01-01

    Highlights of the results obtained on arsenic-doped silicon blocked impurity band (BIB) detectors and arrays since the invention of the BIB concept a few years ago are presented. After a brief introduction and a description of the BIB concept, data will be given on single detector performance. Then different arrays that were fabricated will be described and test data presented.

  4. Comprehensive two-dimensional gas chromatography coupled with fast sulphur-chemiluminescence detection: implications of detector electronics.

    Science.gov (United States)

    Blomberg, Jan; Riemersma, Toby; van Zuijlen, Manfred; Chaabani, Hassan

    2004-09-24

    Within the petrochemical industry, there has been a growing interest in methods capable of providing detailed information on the distribution of sulphur-containing compounds in various product streams, going down to the level of separating and quantifying individual sulphur species. Since no single capillary gas chromatographic column is able to perform this separation, a refuge to multi-dimensional separation techniques has to be taken. In this respect, comprehensive two-dimensional gas chromatography (GC x GC) coupled with sulphur chemiluminescence detection (SCD) has shown to be highly promising. It has been suggested, however, that the detector volume of an SCD restricts its potential to keep up with the fast second-dimension separations of contemporary GC x GC. In this paper, we will demonstrate that the lack of speed of the SCD does not originate from its physical dimensions, but is largely determined by the speed of the electronics used. Additionally, some typical examples will be presented to illustrate the potential of GC x GC coupled with fast SCD.

  5. High-resolution ionization detector and array of such detectors

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, Douglas S. (Ypsilanti, MI); Rojeski, Ronald A. (Pleasanton, CA)

    2001-01-16

    A high-resolution ionization detector and an array of such detectors are described which utilize a reference pattern of conductive or semiconductive material to form interaction, pervious and measurement regions in an ionization substrate of, for example, CdZnTe material. The ionization detector is a room temperature semiconductor radiation detector. Various geometries of such a detector and an array of such detectors produce room temperature operated gamma ray spectrometers with relatively high resolution. For example, a 1 cm.sup.3 detector is capable of measuring .sup.137 Cs 662 keV gamma rays with room temperature energy resolution approaching 2% at FWHM. Two major types of such detectors include a parallel strip semiconductor Frisch grid detector and the geometrically weighted trapezoid prism semiconductor Frisch grid detector. The geometrically weighted detector records room temperature (24.degree. C.) energy resolutions of 2.68% FWHM for .sup.137 Cs 662 keV gamma rays and 2.45% FWHM for .sup.60 Co 1.332 MeV gamma rays. The detectors perform well without any electronic pulse rejection, correction or compensation techniques. The devices operate at room temperature with simple commercially available NIM bin electronics and do not require special preamplifiers or cooling stages for good spectroscopic results.

  6. Multi-channel laser Doppler velocimetry using a two-dimensional optical fiber array for obtaining instantaneous velocity distribution characteristics

    Science.gov (United States)

    Kyoden, Tomoaki; Yasue, Youichi; Ishida, Hiroki; Akiguchi, Shunsuke; Andoh, Tsugunobu; Takada, Yogo; Teranishi, Tsunenobu; Hachiga, Tadashi

    2015-01-01

    A laser Doppler velocimeter (LDV) has been developed that is capable of performing two-dimensional (2D) cross-sectional measurements. It employs two horizontal laser light sheets that intersect at an angle of 13.3°. Since the intersection region is thin, it can be used to approximately determine the 2D flow field. An 8 × 8 array of optical fibers is used to simultaneously measure Doppler frequencies at 64 points. Experiments were conducted to assess the performance of the LDV, and it was found to be capable of obtaining spatial and temporal velocity information at multiple points in a flow field. The technique is fast, noninvasive, and accurate over long sampling periods. Furthermore, its applicability to an actual flow field was confirmed by measuring the temporal velocity distribution of a pulsatile flow in a rectangular flow channel with an obstruction. The proposed device is thus a useful, compact optical instrument for conducting simultaneous 2D cross-sectional multipoint measurements.

  7. Crystallization studies on phase-change optical recording media by use of a two-dimensional periodic mark array.

    Science.gov (United States)

    Xun, X; Erwin, J K; Bletscher, W; Choi, J; Kallenbach, S; Mansuripur, M

    2001-12-10

    We present the results of crystallization studies in thin-film samples of amorphous and crystalline Ge(x)Sb(y)Te(z). The experiments, conducted at moderately elevated temperatures, are based on measurements of the first-order diffraction efficiency from a two-dimensional periodic array of recorded marks. When the samples are slowly heated above room temperature, changes in the efficiencies of various diffracted orders give information about the on-going crystallization process within the sample. Two different compositions of the GeSbTe alloy are used in these experiments. Measurements on Ge(2)Sb(2.3)Te(5) films show crystallization dominated by nucleation. For the Sb-rich eutectic composition Ge-(SbTe), crystallization is found to be dominated by growth from crystalline boundaries. We also show that crystalline marks written by relatively high-power laser pulses are different in their optical properties from the regions crystallized by slow heating of the sample to moderate temperatures.

  8. Two Dimensional Array Based Overlay Network for Balancing Load of Peer-to-Peer Live Video Streaming

    Science.gov (United States)

    Faruq Ibn Ibrahimy, Abdullah; Rafiqul, Islam Md; Anwar, Farhat; Ibn Ibrahimy, Muhammad

    2013-12-01

    The live video data is streaming usually in a tree-based overlay network or in a mesh-based overlay network. In case of departure of a peer with additional upload bandwidth, the overlay network becomes very vulnerable to churn. In this paper, a two dimensional array-based overlay network is proposed for streaming the live video stream data. As there is always a peer or a live video streaming server to upload the live video stream data, so the overlay network is very stable and very robust to churn. Peers are placed according to their upload and download bandwidth, which enhances the balance of load and performance. The overlay network utilizes the additional upload bandwidth of peers to minimize chunk delivery delay and to maximize balance of load. The procedure, which is used for distributing the additional upload bandwidth of the peers, distributes the additional upload bandwidth to the heterogeneous strength peers in a fair treat distribution approach and to the homogeneous strength peers in a uniform distribution approach. The proposed overlay network has been simulated by Qualnet from Scalable Network Technologies and results are presented in this paper.

  9. Metabolite profiling of licorice (Glycyrrhiza glabra) from different locations using comprehensive two-dimensional liquid chromatography coupled to diode array and tandem mass spectrometry detection.

    Science.gov (United States)

    Montero, Lidia; Ibáñez, Elena; Russo, Mariateresa; di Sanzo, Rosa; Rastrelli, Luca; Piccinelli, Anna Lisa; Celano, Rita; Cifuentes, Alejandro; Herrero, Miguel

    2016-03-24

    Profiling of the main metabolites from several licorice (Glycyrrhiza glabra) samples collected at different locations is carried out in this work by using comprehensive two-dimensional liquid chromatography (LC × LC) coupled to diode array (DAD) and mass spectrometry (MS) detectors. The optimized method was based on the application of a HILIC-based separation in the first dimension combined with fast RP-based second dimension separation. This set-up was shown to possess powerful separation capabilities allowing separating as much as 89 different metabolites in a single sample. Identification and grouping of metabolites according to their chemical class were achieved using the DAD, MS and MS/MS data. Triterpene saponins were the most abundant metabolites followed by glycosylated flavanones and chalcones, whereas glycyrrhizic acid, as expected, was confirmed as the main component in all the studied samples. LC × LC-DAD-MS/MS was able to resolve these complex licorice samples providing with specific metabolite profiles to the different licorice samples depending on their geographical origin. Namely, from 19 to 50 specific compounds were exclusively determined in the 2D-chromatograms from the different licorice samples depending on their geographical origin, which can be used as a typical pattern that could potentially be related to their geographical location and authentication.

  10. SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M; SHIN, D; Park, J; Lim, Y; Lee, S; Kim, J [National Cancer Center, Goyang, Gyeonggi-do (Korea, Republic of); Son, J [National Cancer Center, Goyang, Gyeonggi-do, Korea University, Seoul, Gyeonggi-do (Korea, Republic of); Hwang, U [National Medical Center in Korea, Seoul (Korea, Republic of)

    2014-06-15

    Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

  11. Ballistic aggregation on two-dimensional arrays of seeds with oblique incident flux: Growth model for amorphous Si on Si

    Science.gov (United States)

    Ye, D.-X.; Lu, T.-M.

    2007-12-01

    Amorphous silicon (Si) structures on two-dimensional arrays of seeds on a Si substrate were experimentally prepared at near room temperature using a physical vapor deposition system with an 85° oblique incident flux. In the stationary deposition case where the substrate is fixed at a position, the Si on the seeds form a ballistic inclined fanlike structure with an initial cone shape and the fan size R grows with time in a power law form tp , where ptilde 1 . We show that with a swing rotation where the substrate is rotated back-and-forth azimuthally, the fan size grows slower (pshadowing, surface diffusion, and substrate rotation in a three-dimensional Monte Carlo simulator. The evolution of the fanlike structures at different deposition times was simulated for both stationary deposition and swing rotation. The growth of the fan size R with time t in simulations was quantitatively analyzed and the exponents ptilde 1.0 and ptilde 0.46 were extracted for the stationary deposition and the swing rotation, respectively. For stationary deposition, the exponent 1 does not change significantly with the strength of surface diffusion. However, the fan-out angle decreases with the increased strength of surface diffusion. For swing rotation, the reduced exponent 0.46 at the initial stages of growth is primarily due to the self-shadowing of the fan itself under rotation. At the later stages of growth, the saturation of the fan size produces uniform rods and is due to the global shadowing from the adjacent fan structures. The morphology and the exponent obtained from our simulations are consistent with our experimental observations.

  12. Note: A two-dimensional position-sensitive micro-channel plate detector with a cross-connected-pixels resistive anode and integrated spectroscopy amplifiers.

    Science.gov (United States)

    Yang, Liping; Liu, Junliang; Zhang, Yuezhao; Wang, Wei; Yu, Deyang; Li, Xiaoxiao; Li, Xin; Zheng, Min; Ding, Baowei; Cai, Xiaohong

    2017-08-01

    Based on the charge-division method, a compact detector system for charged particles is constructed. The system consists of a pair of micro-channel plates, a novel two-dimensional position-sensitive cross-connected-pixels resistive anode, and specially designed front-end electronics that can directly drive analog-to-digital converters. The detector is tested with an (241)Am α-source. A position resolution of better than 0.3 mm and a maximum distortion within 0.5 mm in the active dimensions of 100 mm diameter are achieved.

  13. Note: A two-dimensional position-sensitive micro-channel plate detector with a cross-connected-pixels resistive anode and integrated spectroscopy amplifiers

    Science.gov (United States)

    Yang, Liping; Liu, Junliang; Zhang, Yuezhao; Wang, Wei; Yu, Deyang; Li, Xiaoxiao; Li, Xin; Zheng, Min; Ding, Baowei; Cai, Xiaohong

    2017-08-01

    Based on the charge-division method, a compact detector system for charged particles is constructed. The system consists of a pair of micro-channel plates, a novel two-dimensional position-sensitive cross-connected-pixels resistive anode, and specially designed front-end electronics that can directly drive analog-to-digital converters. The detector is tested with an 241Am α-source. A position resolution of better than 0.3 mm and a maximum distortion within 0.5 mm in the active dimensions of 100 mm diameter are achieved.

  14. Effects of oblique wave propagation on the nonlinear plasma resonance in the two-dimensional channel of the Dyakonov-Shur detector

    Science.gov (United States)

    Rupper, Greg; Rudin, Sergey; Crowne, Frank J.

    2012-12-01

    In the Dyakonov-Shur terahertz detector the conduction channel of a heterostructure High Electron Mobility Transistor (HEMT) is used as a plasma wave resonator for density oscillations in electron gas. Nonlinearities in the plasma wave propagation lead to a constant source-to-drain voltage, providing the detector output. In this paper, we start with the quasi-classical Boltzmann equation and derive the hydrodynamic model with temperature dependent transport coefficients for a two-dimensional viscous flow. This derivation allows us to obtain the parameters for the hydrodynamic model from the band-structure of the HEMT channel. The treatment here also includes the energy balance equation into the analysis. By numerical solution of the hydrodynamic equations with a non-zero boundary current we evaluate the detector response function and obtain the temperature dependence of the plasma resonance. The present treatment extends the theory of Dyakonov-Shur plasma resonator and detector to account for the temperature dependence of viscosity, the effects of oblique wave propagation on detector response, and effects of boundary current in two-dimensional flow on quality of the plasma resonance. The numerical results are given for a GaN channel. We also investigated a stability of source to drain flow and formation of shock waves.

  15. Astronomical Image Processing with Array Detectors

    CERN Document Server

    Houde, Martin

    2007-01-01

    We address the question of astronomical image processing from data obtained with array detectors. We define and analyze the cases of evenly, regularly, and irregularly sampled maps for idealized (i.e., infinite) and realistic (i.e., finite) detectors. We concentrate on the effect of interpolation on the maps, and the choice of the kernel used to accomplish this task. We show how the normalization intrinsic to the interpolation process must be carefully accounted for when dealing with irregularly sampled grids. We also analyze the effect of missing or dead pixels in the array, and their consequences for the Nyquist sampling criterion.

  16. Standard guide for digital detector array radiology

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This standard is a user guide, which is intended to serve as a tutorial for selection and use of various digital detector array systems nominally composed of the detector array and an imaging system to perform digital radiography. This guide also serves as an in-detail reference for the following standards: Practices E2597, , and E2737. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Comparison of one-dimensional and two-dimensional least-squares strain estimators for phased array displacement data.

    NARCIS (Netherlands)

    Lopata, R.G.P.; Hansen, H.H.G.; Nillesen, M.M.; Thijssen, J.M.; Korte, C.L. de

    2009-01-01

    In this study, the performances of one-dimensional and two-dimensional least-squares strain estimators (LSQSE) are compared. Furthermore, the effects of kernel size are examined using simulated raw frequency data of a widely-adapted hard lesion/soft tissue model. The performances of both methods are

  18. Characteristics of Acoustic Field of Two-dimensional Ultrasonic Phased Array%二维超声相控阵的声场特性

    Institute of Scientific and Technical Information of China (English)

    龙绒蓉; 王海涛; 郭瑞鹏; 徐君; 郭艳; 沈立军

    2015-01-01

    基于空间冲激响应的脉冲声场模型及超声相控阵指向性理论,使用 MATLAB 仿真软件,分析了二维矩形阵列各参数对其声场特性的影响,据此推导出阵列探头设计、选取的一般准则;对比研究二维矩形阵列和圆形阵列的脉冲回波声场。结果表明,圆形阵列具有更窄的主瓣宽度和更低的第一级旁瓣,更优的指向性。%Based on the pulsed ultrasonic field model of the space impulse response and the directivity theory of ultrasonic phased array,the effect of two-dimensional rectangular array parameters on the acoustical characteristics was investigated by using MATLAB simulation software.Accordingly,the general guidelines of array probe design and selection was derived.Comparative studies were also carried on the pulse-echo acoustic field of two-dimensional rectangular array and circular array,showing that the circular array had a narrower width of main lobe and lower first side lobe,etc,so the performance of the latter being more outstanding.

  19. Encapsulated thermopile detector array for IR microspectrometer

    NARCIS (Netherlands)

    Wu, H.; Emadi, A.; De Graaf, G.; Wolffenbuttel, R.F.

    2010-01-01

    The miniaturized IR spectrometer discussed in this paper is comprised of: slit, planar imaging diffraction grating and Thermo-Electric (TE) detector array, which is fabricated using CMOS compatible MEMS technology. The resolving power is maximized by spacing the TE elements at an as narrow as possib

  20. Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range.

    Science.gov (United States)

    Adams, Bernhard W; Mane, Anil U; Elam, Jeffrey W; Obaid, Razib; Wetstein, Matthew; Chollet, Matthieu

    2015-09-01

    X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range.

  1. Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Bernhard W.; Mane, Anil; Elam, Jeffrey; Obaid, Razib; Wetstein, Matthew J.

    2015-09-01

    X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range.

  2. Cosmic-ray Detector with Interdigitated-Finger Pixels for two-dimensional Position Information from a Singel Wafer Side

    Science.gov (United States)

    Cunningham, Thomas J.; Mazed, Mohammad; Holtzman, Melinda J.; Fossum, Eric R.

    1993-01-01

    This paper describes a type of cosmic ray detector for isotopic and energy detection of energetic nuclei which derives both dimensions of position information from one side of the detector. This simplifies the required readout electronics, since only one precision amplifier connected to the other side is required for an accurate detection of the energy loss.

  3. Spallation reactions studied with 4-detector arrays

    Indian Academy of Sciences (India)

    J Galin

    2001-07-01

    Recently there has been a renewed interest in the study of spallation reactions in basic nuclear physics as well as in potential applications. Spallation reactions induced by light projectiles (protons, antiprotons, pions, etc.) in the GeV range allow the formation of hot nuclei which do not suffer the collective excitations (compression, rotation, deformation) unavoidable when using massive projectiles. Such nuclei provide an ideal testbench for probing their decay as a function of excitation energy. In these investigations, 4-detector arrays for charged particles and neutrons play a major role in the event-by-event sorting according to the excitation energy of the nucleus. Spallation reactions induced on heavy nuclei allow the conversion of the incident GeV proton into several tens of evaporated neutrons. The neutron production in thick targets has been investigated in great detail thanks to the use of high efficiency neutron detector arrays. When scattered on samples of inert or biological materials, these neutrons can be used to study details of the material structure. They could also be utilized for the transmutation of long-lived nuclear wastes or for the feeding of sub-critical nuclear reactors. The role of different types of multi-detector arrays is highlighted in this paper. Several references are also given for different uses of high efficiency neutron detectors in other contexts.

  4. Fabrication of large-sized two-dimensional ordered surface array with well-controlled structure via colloidal particle lithography.

    Science.gov (United States)

    Meng, Xiaohui; Zhang, Xinping; Ye, Lei; Qiu, Dong

    2014-06-17

    Epoxy resin coated glass slides were used for colloidal particle lithography, in order to prepare well-defined 2D surface arrays. Upon the assistance of a large-sized 2D colloidal single crystal as template, centimeter-sized ordered surface arrays of bowl-like units were obtained. Systematic studies revealed that the parameters of obtained surface arrays could be readily controlled by some operational factors, such as temperature, epoxy resin layer thickness, and template particle size. With epoxy resin substituting for normal linear polymer, the height/diameter ratio of bowls in the formed surface arrays can be largely increased. With further reactive plasma etching, the parameters of ordered surface arrays could be finely tuned through controlling etching time. This study provides a facile way to prepare large-sized 2D surface arrays with tunable parameters.

  5. The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B. [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

    2013-11-15

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly {sup 192}Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m{sup 2}/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the {sup 192}Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a {sup 192}Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm

  6. Silicon-on-insulator multimode-interference waveguide-based arrayed optical tweezers (SMART) for two-dimensional microparticle trapping and manipulation.

    Science.gov (United States)

    Lei, Ting; Poon, Andrew W

    2013-01-28

    We demonstrate two-dimensional optical trapping and manipulation of 1 μm and 2.2 μm polystyrene particles in an 18 μm-thick fluidic cell at a wavelength of 1565 nm using the recently proposed Silicon-on-insulator Multimode-interference (MMI) waveguide-based ARrayed optical Tweezers (SMART) technique. The key component is a 100 μm square-core silicon waveguide with mm length. By tuning the fiber-coupling position at the MMI waveguide input facet, we demonstrate various patterns of arrayed optical tweezers that enable optical trapping and manipulation of particles. We numerically simulate the physical mechanisms involved in the arrayed trap, including the optical force, the heat transfer and the thermal-induced microfluidic flow.

  7. A tiled CCD detector with 2x2 array and tapered fibre optics for electron microscopy

    CERN Document Server

    Faruqi, A R; Cattermole, D M; Stubbings, S

    2002-01-01

    Charge coupled devices (CCD)-based detectors have made a major impact on data collection in electron microscopy over the past few years. There have been a number of successful applications of CCDs in electron crystallography of two-dimensional protein crystal arrays but high-resolution imaging has been hampered by the relatively poor spatial resolution (and fewer independent pixels) compared to film. A partial solution to this problem, presented in this paper, are to design detectors with larger effective pixel sizes and with more pixels. A CCD detector with a much greater number of 'independent' pixels, achieved by tiling a 2x2 array of CCDs, each of which has 1242x1152 pixels is described here. The sensitive area of the detector, using fibre optics with a demagnification of 2.5 : 1, is 140x130 mm sup 2; the pixel size is 56 mu m square and there is a total of approx 2500x2300 pixels.

  8. Flow-modulated comprehensive two-dimensional gas chromatography combined with a vacuum ultraviolet detector for the analysis of complex mixtures.

    Science.gov (United States)

    Zoccali, Mariosimone; Schug, Kevin A; Walsh, Phillip; Smuts, Jonathan; Mondello, Luigi

    2017-05-12

    The present paper is focused on the use of a vacuum ultraviolet absorption spectrometer (VUV) for gas chromatography (GC), within the context of flow modulated comprehensive two-dimensional gas chromatography (FM GC×GC). The features of the VUV detector were evaluated through the analysis of petrochemical and fatty acids samples. Besides responding in a predictable fashion via Beer's law principles, the detector provides additional spectroscopic information for qualitative analysis. Virtually all chemical species absorb and have unique gas phase absorption features in the 120-240nm wavelength range monitored. The VUV detector can acquire up to 90 full range absorption spectra per second, allowing its coupling with comprehensive two-dimensional gas chromatography. This recent form of detection can address specific limitations related to mass spectrometry (e.g., identification of isobaric and isomeric species with very similar mass spectra or labile chemical compounds), and it is also able to deconvolute co-eluting peaks. Moreover, it is possible to exploit a pseudo-absolute quantitation of analytes based on pre-recorded absorption cross-sections for target analytes, without the need for traditional calibration. Using this and the other features of the detector, particular attention was devoted to the suitability of the FM GC×GC-VUV system toward qualitative and quantitative analysis of bio-diesel fuel and different kinds of fatty acids. Satisfactory results were obtained in terms of tailing factor (1.1), asymmetry factor (1.1), and similarity (average value 97%), for the FAMEs mixtures analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Real-Time Two-Dimensional Mapping of Relative Local Surface Temperatures with a Thin-Film Sensor Array

    Directory of Open Access Journals (Sweden)

    Gang Li

    2016-06-01

    Full Text Available Dynamic mapping of an object’s local temperature distribution may offer valuable information for failure analysis, system control and improvement. In this letter we present a computerized measurement system which is equipped with a hybrid, low-noise mechanical-electrical multiplexer for real-time two-dimensional (2D mapping of surface temperatures. We demonstrate the performance of the system on a device embedded with 32 pieces of built-in Cr-Pt thin-film thermocouples arranged in a 4 × 8 matrix. The system can display a continuous 2D mapping movie of relative temperatures with a time interval around 1 s. This technique may find applications in a variety of practical devices and systems.

  10. Surface Light Extraction Mapping from Two-Dimensional Array of 12-Fold Photonic Quasicrystal on Current Injected GaN-Based LEDs

    Institute of Scientific and Technical Information of China (English)

    DAI Tao; ZHU Xing; ZHANG Bei; ZHANG Zhen-Sheng; LIU Dan; WANG Xiao; BAO Kui; KANG Xiang-Ning; XU Jun; Yu Da-Peng

    2007-01-01

    A two-dimensional array of dodecagonal photonic quasicrystal(12PQC)is fabricated on the surface of current injected GaN-based LEDs to out-couple guided modes.The spatially-resolved surface light extraction mapping of 12PQC is observed and compared with that of triangular lattice photonic crystal (3PC)by microscopic electrical luminescence and scanning near-field microscopy.The higher enhancement factor of 12PQC is obtained to be larger than that of 3PC.It is shown that 12PQC is more favourable and efficient for light extraction of guided lights.

  11. Piezoelectric-paint-based two-dimensional phased sensor arrays for structural health monitoring of thin panels

    Science.gov (United States)

    Yoo, B.; Purekar, A. S.; Zhang, Y.; Pines, D. J.

    2010-07-01

    A damage detection method based on an innovative 2D phased sensor array made of piezoelectric paint is proposed for in situ damage detection of a thin isotropic panel using guided Lamb waves. A design analysis of candidate 2D arrays based on spiral, cruciform and circular element layouts is performed. In this study, a 2D phased sensor array with a spiral configuration is fabricated using a piezoelectric composite (piezopaint) patch and used for detecting damages in an aluminum panel. Steered array responses are generated from the raw sensor signals using a directional filtering algorithm based on phased array signal processing. The fundamental flexural (or transverse), A0 mode, of the guided Lamb waves is used though the sensing and analysis technique is not limited to the mode used in this work. To enhance the proposed analysis technique, empirical mode decomposition (EMD) and a Hilbert-Huang transform (HHT) are applied. A new damage detection algorithm including threshold setting and damage index (DI) calculation is developed and implemented for detecting damages in the form of holes and a simulated crack. The characteristic damage indices consistently increase as damage size grows.

  12. Spiral biasing adaptor for use in Si drift detectors and Si drift detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zheng; Chen, Wei

    2016-07-05

    A drift detector array, preferably a silicon drift detector (SDD) array, that uses a low current biasing adaptor is disclosed. The biasing adaptor is customizable for any desired geometry of the drift detector single cell with minimum drift time of carriers. The biasing adaptor has spiral shaped ion-implants that generate the desired voltage profile. The biasing adaptor can be processed on the same wafer as the drift detector array and only one biasing adaptor chip/side is needed for one drift detector array to generate the voltage profiles on the front side and back side of the detector array.

  13. Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy

    Science.gov (United States)

    Kim, Yon-Lae; Chung, Jin-Beom; Kim, Jae-Sung; Lee, Jeong-Woo; Choi, Kyoung-Sik

    2014-04-01

    The aim of this study was to compare the dosimetric performance and to evaluate the pretreatment quality assurance (QA) of a portal dosimetry and a commercial two-dimensional (2-D) array system. In the characteristics comparison study, the measured values for the dose linearity, dose rate response, reproducibility, and field size dependence for 6-MV photon beams were analyzed for both detector systems. To perform the qualitative evaluations of the 10 IMRT and the 10 VMAT plans, we used the Gamma index for quantifying the agreement between calculations and measurements. The performance estimates for both systems show that overall, minimal differences in the dosimetric characteristics exist between the Electron portal imaging device (EPID) and 2-D array system. In the qualitative analysis for pretreatment quality assurance, the EPID and 2-D array system yield similar passing rate results for the majority of clinical Intensity-modulated radiation therapy (IMRT) and Volumetric-modulated arc therapy (VMAT) cases. These results were satisfactory for IMRT and VMAT fields and were within the acceptable criteria of γ%≤1, γ avg <0.5. The EPDI and the 2-D array systems showed comparable dosimetric results. In this study, the results revealed both systems to be suitable for patient-specific QA measurements for IMRT and VMAT. We conclude that, depending on the status of clinic, both systems can be used interchangeably for routine pretreatment QA.

  14. Operation in the turbulent jet field of a linear array of multiple rectangular jets using a two-dimensional jet (Variation of mean velocity field

    Directory of Open Access Journals (Sweden)

    Fujita Shigetaka

    2016-01-01

    Full Text Available The mean flowfield of a linear array of multiple rectangular jets run through transversely with a two-dimensional jet, has been investigated, experimentally. The object of this experiment is to operate both the velocity scale and the length scale of the multiple rectangular jets using a two-dimensional jet. The reason of the adoption of this nozzle exit shape was caused by the reports of authors in which the cruciform nozzle promoted the inward secondary flows strongly on both the two jet axes. Aspect ratio of the rectangular nozzle used in this experiment was 12.5. Reynolds number based on the nozzle width d and the exit mean velocity Ue (≅ 39 m / s was kept constant 25000. Longitudinal mean velocity was measured using an X-array Hot-Wire Probe (lh = 3.1 μm in diameter, dh = 0.6 mm effective length : dh / lh = 194 operated by the linearized constant temperature anemometers (DANTEC, and the spanwise and the lateral mean velocities were measured using a yaw meter. The signals from the anemometers were passed through the low-pass filters and sampled using A.D. converter. The processing of the signals was made by a personal computer. Acquisition time of the signals was usually 60 seconds. From this experiment, it was revealed that the magnitude of the inward secondary flows on both the y and z axes in the upstream region of the present jet was promoted by a two-dimensional jet which run through transversely perpendicular to the multiple rectangular jets, therefore the potential core length on the x axis of the present jet extended 2.3 times longer than that of the multiple rectangular jets, and the half-velocity width on the rectangular jet axis of the present jet was suppressed 41% shorter compared with that of the multiple rectangular jets.

  15. Operation in the turbulent jet field of a linear array of multiple rectangular jets using a two-dimensional jet (Variation of mean velocity field)

    Science.gov (United States)

    Fujita, Shigetaka; Harima, Takashi

    2016-03-01

    The mean flowfield of a linear array of multiple rectangular jets run through transversely with a two-dimensional jet, has been investigated, experimentally. The object of this experiment is to operate both the velocity scale and the length scale of the multiple rectangular jets using a two-dimensional jet. The reason of the adoption of this nozzle exit shape was caused by the reports of authors in which the cruciform nozzle promoted the inward secondary flows strongly on both the two jet axes. Aspect ratio of the rectangular nozzle used in this experiment was 12.5. Reynolds number based on the nozzle width d and the exit mean velocity Ue (≅ 39 m / s) was kept constant 25000. Longitudinal mean velocity was measured using an X-array Hot-Wire Probe (lh = 3.1 μm in diameter, dh = 0.6 mm effective length : dh / lh = 194) operated by the linearized constant temperature anemometers (DANTEC), and the spanwise and the lateral mean velocities were measured using a yaw meter. The signals from the anemometers were passed through the low-pass filters and sampled using A.D. converter. The processing of the signals was made by a personal computer. Acquisition time of the signals was usually 60 seconds. From this experiment, it was revealed that the magnitude of the inward secondary flows on both the y and z axes in the upstream region of the present jet was promoted by a two-dimensional jet which run through transversely perpendicular to the multiple rectangular jets, therefore the potential core length on the x axis of the present jet extended 2.3 times longer than that of the multiple rectangular jets, and the half-velocity width on the rectangular jet axis of the present jet was suppressed 41% shorter compared with that of the multiple rectangular jets.

  16. Damage-free top-down processes for fabricating two-dimensional arrays of 7 nm GaAs nanodiscs using bio-templates and neutral beam etching

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xuanyu; Huang, Chi-Hsien; Tsukamoto, Rikako; Samukawa, Seiji [Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Mortemousque, Pierre-Andre; Itoh, Kohei M; Ohno, Yuzo, E-mail: samukawa@ifs.tohoku.ac.jp [Japan Science and Technology Agency, CREST, 5 Sanbancho, Chiyoda, Tokyo 102-0075 (Japan)

    2011-09-07

    The first damage-free top-down fabrication processes for a two-dimensional array of 7 nm GaAs nanodiscs was developed by using ferritin (a protein which includes a 7 nm diameter iron core) bio-templates and neutral beam etching. The photoluminescence of GaAs etched with a neutral beam clearly revealed that the processes could accomplish defect-free etching for GaAs. In the bio-template process, to remove the ferritin protein shell without thermal damage to the GaAs, we firstly developed an oxygen-radical treatment method with a low temperature of 280 deg. C. Then, the neutral beam etched the defect-free nanodisc structure of the GaAs using the iron core as an etching mask. As a result, a two-dimensional array of GaAs quantum dots with a diameter of {approx} 7 nm, a height of {approx} 10 nm, a high taper angle of 88 deg. and a quantum dot density of more than 7 x 10{sup 11} cm{sup -2} was successfully fabricated without causing any damage to the GaAs.

  17. Two-Dimensional DOA and Polarization Estimation for a Mixture of Uncorrelated and Coherent Sources with Sparsely-Distributed Vector Sensor Array.

    Science.gov (United States)

    Si, Weijian; Zhao, Pinjiao; Qu, Zhiyu

    2016-05-31

    This paper presents an L-shaped sparsely-distributed vector sensor (SD-VS) array with four different antenna compositions. With the proposed SD-VS array, a novel two-dimensional (2-D) direction of arrival (DOA) and polarization estimation method is proposed to handle the scenario where uncorrelated and coherent sources coexist. The uncorrelated and coherent sources are separated based on the moduli of the eigenvalues. For the uncorrelated sources, coarse estimates are acquired by extracting the DOA information embedded in the steering vectors from estimated array response matrix of the uncorrelated sources, and they serve as coarse references to disambiguate fine estimates with cyclical ambiguity obtained from the spatial phase factors. For the coherent sources, four Hankel matrices are constructed, with which the coherent sources are resolved in a similar way as for the uncorrelated sources. The proposed SD-VS array requires only two collocated antennas for each vector sensor, thus the mutual coupling effects across the collocated antennas are reduced greatly. Moreover, the inter-sensor spacings are allowed beyond a half-wavelength, which results in an extended array aperture. Simulation results demonstrate the effectiveness and favorable performance of the proposed method.

  18. Two-Dimensional DOA and Polarization Estimation for a Mixture of Uncorrelated and Coherent Sources with Sparsely-Distributed Vector Sensor Array

    Directory of Open Access Journals (Sweden)

    Weijian Si

    2016-05-01

    Full Text Available This paper presents an L-shaped sparsely-distributed vector sensor (SD-VS array with four different antenna compositions. With the proposed SD-VS array, a novel two-dimensional (2-D direction of arrival (DOA and polarization estimation method is proposed to handle the scenario where uncorrelated and coherent sources coexist. The uncorrelated and coherent sources are separated based on the moduli of the eigenvalues. For the uncorrelated sources, coarse estimates are acquired by extracting the DOA information embedded in the steering vectors from estimated array response matrix of the uncorrelated sources, and they serve as coarse references to disambiguate fine estimates with cyclical ambiguity obtained from the spatial phase factors. For the coherent sources, four Hankel matrices are constructed, with which the coherent sources are resolved in a similar way as for the uncorrelated sources. The proposed SD-VS array requires only two collocated antennas for each vector sensor, thus the mutual coupling effects across the collocated antennas are reduced greatly. Moreover, the inter-sensor spacings are allowed beyond a half-wavelength, which results in an extended array aperture. Simulation results demonstrate the effectiveness and favorable performance of the proposed method.

  19. Coherent Excitonic Wavepackets in Two-Dimensional Square Dot-Arrays Driven by an In-Plane Uniform Electric Field

    Institute of Scientific and Technical Information of China (English)

    李秀平; 阎维贤

    2004-01-01

    We investigate the evolution behaviour of electron-hole pair wavepacket in optically excited square quantum-dot arrays driven by in-plane (x-y plane) uniform electric field E (viz, E = Exex + Eyey, ex,ey are unit vectors along x and y directions respectively), in the time domain. It is found that if the ratio of the x-component electric field Ex to the y-component electric field Ey is a rational p/q (p and q being coprime integer numbers),the wavepackets undergo a time-periodic breathing mode, with the period 2πp/ωBx, where ωBx = eExa/h, with a being the lattice constant of square dot arrays, h being Planck's constant, e being the electron charge. This finding provides a time-domain demonstration of the recent spectral result [Phys. Rev. Lett. 86 (2001)3116].

  20. Understanding the role of surface plasmon polaritons in two-dimensional achiral nanohole arrays for polarization conversion

    CERN Document Server

    Cao, Z L; Zhang, Z Q; Chan, C T; Ong, H C

    2016-01-01

    We have studied the dependence of the rotation angle and ellipticity on the sample orientation and incident polarization from metallic nanohole arrays. The arrays have four-fold symmetry and thus do not possess any intrinsic chirality. We elucidate the role of surface plasmon polaritons (SPPs) in determining the extrinsic chirality and we verify the results by using finite-difference time-domain simulation. Our results have indicated the outgoing reflection arises from the interference between the nonresonant background, which preserves the input polarization, and the SPP radiation damping, which is linearly polarized but carries a different polarization defined by the vectorial field of SPPs. More importantly, the interference manifests various polarization states ranging from linear to elliptical across the SPP resonance. We analytically formulate the outgoing waves based on temporal coupled mode theory (CMT) and the results agree well with the experiment and simulation. From CMT, we find the polarization c...

  1. The Development of a Two-Dimensional Multielectrode Array for Visual Perception Research in the Mammalian Brain.

    Science.gov (United States)

    1980-12-01

    two areas called the primary visual cortex (Ari,; 17 of Brod;.iann) and the secondary visual cortex ( Area 18 of Brodmann ). Figure 4 shows the location...may improve our knowledge of the human visual system. Motivation for such) a project lies in two fundamental areas . The first area concerns the...seemingly unrelated areas : pattern recognition and human neurology. The array is designed to obtain r fi: e zi:ied data from the visial cortex of a

  2. Low-energy CZT detector array for the ASIM mission

    DEFF Research Database (Denmark)

    Cenkeramaddi, Linga Reddy; Genov, Georgi; Kohfeldt, Anja

    2012-01-01

    In this article we introduce the low-energy CZT (CdZnTe) 16 384-pixel detector array on-board the Atmosphere Space Interaction Monitor (ASIM), funded by the European Space Agency. This detector is a part of the larger Modular X-and Gamma-ray sensor (MXGS). The CZT detector array is sensitive...

  3. Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array

    CERN Document Server

    Bisigello, L; Ferrari, L; Baselmans, J J A; Baryshev, A M

    2016-01-01

    The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequency and are coupled to each other producing crosstalk. Because crosstalk can be only minimised by improving the array design, in this work we aim to correct for this effect a posteriori. We analysed a MKID array consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the beam patterns for every detector in the array and described the response of each detector by using a two-dimensional Gaussian fit. Then, we identified detectors affected by crosstalk above -30 dB level from the maximum and removed the signal of the crosstalking detectors. Moreover, we modelled the crosstalk level for each KID as a func...

  4. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics

    Science.gov (United States)

    Kuhls-Gilcrist, Andrew T.; Gupta, Sandesh K.; Bednarek, Daniel R.; Rudin, Stephen

    2010-01-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks. PMID:21243038

  5. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Keckes, J; Conka Nurdan, T; Send, S; Micha, J S; Ulrich, O; Hartmann, R; Strüder, L; Pietsch, U

    2017-06-01

    The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation with an energy range from 5 to 23 keV. Microbeam X-ray Laue diffraction patterns were collected from a copper micro-bending beam along the central axis (centroid of the cross section). Taking advantage of a two-dimensional energy-dispersive X-ray detector (pnCCD), the position and energy of the collected Laue spots were measured for multiple positions on the sample, allowing the measurement of variations in the local microstructure. At the same time, both the deviatoric and hydrostatic components of the elastic strain and stress tensors were calculated.

  6. Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

    Science.gov (United States)

    Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham

    2013-09-01

    Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an

  7. Vertically Aligned Two-Dimensional Graphene-Metal Hydroxide Hybrid Arrays for Li-O2 Batteries.

    Science.gov (United States)

    Zhu, Jixin; Metzger, Michael; Antonietti, Markus; Fellinger, Tim-Patrick

    2016-10-05

    Lithium oxygen batteries (LOBs) are a very promising upcoming technology which, however, still suffers from low lifespan and dramatic capacities fading. Solid discharge products increase the contact resistance and block the electrochemically active electrodes. The resulting high oxidative potentials and formation of Li2CO3 due to electrolyte and carbon electrode decomposition at the positive electrode lead to irreversible deactivation of oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) sites. Here we demonstrate a facile strategy for the scalable production of a new electrode structure constituted of vertically aligned carbon nanosheets and metal hydroxide (M(OH)x@CNS) hybrid arrays, integrating both favorable ORR and OER active materials to construct bifunctional catalysts for LOBs. Excellent lithium-oxygen battery properties with high specific capacity of 5403 mAh g(-1) and 12123 mAh g(-1) referenced to the carbon and M(OH)x weight, respectively, long cyclability, and low charge potentials are achieved in the resulting M(OH)x@CNS cathode architecture. The properties are explained by improved O2/ion transport properties and spatially limited precipitation of Li2O2 nanoparticles inside interstitial cavities resulting in high reversibility. The strategy of creating ORR and OER bifunctional catalysts in a single conductive hybrid component may pave the way to new cathode architectures for metal air batteries.

  8. Advanced ACTPol Cryogenic Detector Arrays and Readout

    Science.gov (United States)

    Henderson, S. W.; Allison, R.; Austermann, J.; Baildon, T.; Battaglia, N.; Beall, J. A.; Becker, D.; De Bernardis, F.; Bond, J. R.; Calabrese, E.; Choi, S. K.; Coughlin, K. P.; Crowley, K. T.; Datta, R.; Devlin, M. J.; Duff, S. M.; Dunkley, J.; Dünner, R.; van Engelen, A.; Gallardo, P. A.; Grace, E.; Hasselfield, M.; Hills, F.; Hilton, G. C.; Hincks, A. D.; Hloẑek, R.; Ho, S. P.; Hubmayr, J.; Huffenberger, K.; Hughes, J. P.; Irwin, K. D.; Koopman, B. J.; Kosowsky, A. B.; Li, D.; McMahon, J.; Munson, C.; Nati, F.; Newburgh, L.; Niemack, M. D.; Niraula, P.; Page, L. A.; Pappas, C. G.; Salatino, M.; Schillaci, A.; Schmitt, B. L.; Sehgal, N.; Sherwin, B. D.; Sievers, J. L.; Simon, S. M.; Spergel, D. N.; Staggs, S. T.; Stevens, J. R.; Thornton, R.; Van Lanen, J.; Vavagiakis, E. M.; Ward, J. T.; Wollack, E. J.

    2016-08-01

    Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies—imaged in intensity and polarization at few arcminute-scale resolution—will enable precision cosmological constraints and also a wide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the Advanced ACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the Advanced ACTPol cryogenic detector arrays.

  9. Very Large Scale Integration of Nano-Patterned YBa2Cu3O7-delta Josephson Junctions in a Two-Dimensional Array

    Energy Technology Data Exchange (ETDEWEB)

    Cybart, Shane A; Anton, Steven; Wu, Stephen; Clarke, John; Dynes, Robert

    2009-09-01

    Very large scale integration of Josephson junctions in a two-dimensional series-parallel array has been achieved by ion irradiating a YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} film through slits in a nano-fabricated mask created with electron beam lithography and reactive ion etching. The mask consisted of 15,820 high-aspect ratio (20:1), 35-nm wide slits that restricted the irradiation in the film below to form Josephson junctions. Characterizing each parallel segment k, containing 28 junctions, with a single critical current I{sub ck} we found a standard deviation in I{sub ck} of about 16%.

  10. Model independent search for new particles in two-dimensional mass space using events with missing energy, two jets and two leptons with the CMS detector

    CERN Document Server

    AUTHOR|(CDS)2080070; Hebbeker, Thomas

    2017-07-07

    The discovery of a new particle consistent with the standard model Higgs boson at the Large Hadron Collider in 2012 completed the standard model of particle physics (SM). Despite its remarkable success many questions remain unexplained. Numerous theoretical models, predicting the existence of new heavy particles, provide answers to these unresolved questions and are tested at high energy experiments such as the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). In this thesis a model independent search method for new particles in two-dimensional mass space in events with missing transverse energy is presented using 19.7 $\\mbox{fb}^{-1}$ of proton-proton collision data recorded by the CMS detector at a centre of mass energy $\\sqrt{s}$ = 8 TeV at the LHC. The analysis searches for signatures of pair-produced new heavy particles $\\mbox{T}^\\prime$ which decay further into unknown heavy particles $\\mbox{W}^\\prime$ and SM quarks $q$ ($\\mbox{T}^\\prime\\overline{\\mbox{T}^\\prime} \\rightarrow {...

  11. Simple and rapid CD4 testing based on large-field imaging system composed of microcavity array and two-dimensional photosensor.

    Science.gov (United States)

    Saeki, Tatsuya; Sugamura, Yuriko; Hosokawa, Masahito; Yoshino, Tomoko; Lim, Tae-Kyu; Harada, Manabu; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2015-05-15

    This study presents a novel method for CD4 testing based on one-shot large-field imaging. The large-field imaging system was fabricated by a microcavity array and a two-dimensional (2D) photosensor within the desk-top-sized instrument. The microcavity array was employed to separate leukocytes from whole blood based on differences in the size of leukocytes and other blood cells. The large-field imaging system with lower side irradiation enabled acquisition of cell signatures with high signal-to-noise ratio, because the metallic substrate of the microcavity array obstructed excessive excitation light. In this setting, dual-color imaging of CD4(+) and CD8(+) T cells was achieved within the entire image area (64 mm(2)) in 2s. The practical performance of the large-field imaging system was demonstrated by determining the CD4/CD8 ratio in a few microliter of control whole blood as small as those obtained by a finger prick. The CD4/CD8 ratios measured using the large-field imaging system correlated well with those measured by microscopic analysis. These results indicate that our proposed system provides a simple and rapid CD4 testing for the application of HIV/AIDS treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Electronics design of a PET detector module with APD array

    CERN Document Server

    Wang Yong

    2002-01-01

    The author summarizes the advantages of APD-array for using in PET scanner. The front-end electronics for an experimental APD detector module was built and tested. According to the characteristics of APD-array and the demands of the signal readout in PET scanner, the full electronics system of an APD detector module was designed and presented in detail

  13. The Impact of Array Detectors on Raman Spectroscopy

    Science.gov (United States)

    Denson, Stephen C.; Pommier, Carolyn J. S.; Denton, M. Bonner

    2007-01-01

    The impact of array detectors in the field of Raman spectroscopy and all low-light-level spectroscopic techniques is examined. The high sensitivity of array detectors has allowed Raman spectroscopy to be used to detect compounds at part per million concentrations and to perform Raman analyses at advantageous wavelengths.

  14. Controlled growth of high-density CdS and CdSe nanorod arrays on selective facets of two-dimensional semiconductor nanoplates

    KAUST Repository

    Wu, Xue-Jun

    2016-03-14

    The rational synthesis of hierarchical three-dimensional nanostructures with specific compositions, morphologies and functionalities is important for applications in a variety of fields ranging from energy conversion and electronics to biotechnology. Here, we report a seeded growth approach for the controlled epitaxial growth of three types of hierarchical one-dimensional (1D)/two-dimensional (2D) nanostructures, where nanorod arrays of II-VI semiconductor CdS or CdSe are grown on the selective facets of hexagonal-shaped nanoplates, either on the two basal facets of the nanoplate, or on one basal facet, or on the two basal facets and six side facets. The seed engineering of 2D hexagonal-shaped nanoplates is the key factor for growth of the three resulting types of 1D/2D nanostructures. The wurtzite- and zinc-blende-type polymorphs of semiconductors are used to determine the facet-selective epitaxial growth of 1D nanorod arrays, resulting in the formation of different hierarchical three-dimensional (3D) nanostructures. © 2016 Macmillan Publishers Limited. All rights reserved.

  15. Controlled growth of high-density CdS and CdSe nanorod arrays on selective facets of two-dimensional semiconductor nanoplates.

    Science.gov (United States)

    Wu, Xue-Jun; Chen, Junze; Tan, Chaoliang; Zhu, Yihan; Han, Yu; Zhang, Hua

    2016-05-01

    The rational synthesis of hierarchical three-dimensional nanostructures with specific compositions, morphologies and functionalities is important for applications in a variety of fields ranging from energy conversion and electronics to biotechnology. Here, we report a seeded growth approach for the controlled epitaxial growth of three types of hierarchical one-dimensional (1D)/two-dimensional (2D) nanostructures, where nanorod arrays of II-VI semiconductor CdS or CdSe are grown on the selective facets of hexagonal-shaped nanoplates, either on the two basal facets of the nanoplate, or on one basal facet, or on the two basal facets and six side facets. The seed engineering of 2D hexagonal-shaped nanoplates is the key factor for growth of the three resulting types of 1D/2D nanostructures. The wurtzite- and zinc-blende-type polymorphs of semiconductors are used to determine the facet-selective epitaxial growth of 1D nanorod arrays, resulting in the formation of different hierarchical three-dimensional (3D) nanostructures.

  16. Controlled growth of high-density CdS and CdSe nanorod arrays on selective facets of two-dimensional semiconductor nanoplates

    Science.gov (United States)

    Wu, Xue-Jun; Chen, Junze; Tan, Chaoliang; Zhu, Yihan; Han, Yu; Zhang, Hua

    2016-05-01

    The rational synthesis of hierarchical three-dimensional nanostructures with specific compositions, morphologies and functionalities is important for applications in a variety of fields ranging from energy conversion and electronics to biotechnology. Here, we report a seeded growth approach for the controlled epitaxial growth of three types of hierarchical one-dimensional (1D)/two-dimensional (2D) nanostructures, where nanorod arrays of II-VI semiconductor CdS or CdSe are grown on the selective facets of hexagonal-shaped nanoplates, either on the two basal facets of the nanoplate, or on one basal facet, or on the two basal facets and six side facets. The seed engineering of 2D hexagonal-shaped nanoplates is the key factor for growth of the three resulting types of 1D/2D nanostructures. The wurtzite- and zinc-blende-type polymorphs of semiconductors are used to determine the facet-selective epitaxial growth of 1D nanorod arrays, resulting in the formation of different hierarchical three-dimensional (3D) nanostructures.

  17. A new scintillating-fiber-array neutron detector

    CERN Document Server

    Zhang Qi; Xie Zhong Shen; Cao Jin Yun; Niu Shen Gli; Ouyang Xia Opin

    2002-01-01

    A new scintillating-fiber-array neutron detector has been developed. The detector consists of a bee-hive-shaped lead absorber, a scintillating fiber array, a light guide, a filter and a photomultiplier tube. The experimental results show that the new detector's neuron-to-gamma sensitivity ratio is improved about six times compared to traditional plastic scintillation detectors to 2.5 MeV neutrons and 1.25 MeV gamma rays. Hence, the detector should be very useful in the measurements of pulsed neutrons from fission reactions in a neutron-gamma mixed field.

  18. Results from the Puebla extensive air shower detector array

    Science.gov (United States)

    Salazar, H.; Martinez, O.; Moreno, E.; Cotzomi, J.; Villaseñor, L.; Saavedrac, O.

    2003-07-01

    We describe the design and operation of the first stage of the EAS-UAP extensive air shower array, as a detector of very high energy cosmic rays ( Eo > 10 14eV). The array is located at the Campus of Puebla University and consists of 18 liquid scintillator detectors, with an active surface of 1 m2 each and a detector spacing of 20 m in a square grid. In this report we discuss the stability and the calibration of the detector array, as derived from the 10 detectors in operation in the first stage. The main characteristics of the array allow us also to use it as an educational and training facility. First distributions of the arrival direction and the lateral shower srpead are also given.

  19. INTERDISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Instability and Death of Spiral Wave in a Two-Dimensional Array of Hindmarsh-Rose Neurons

    Science.gov (United States)

    Wang, Chun-Ni; Ma, Jun; Tang, Jun; Li, Yan-Long

    2010-02-01

    Spiral wave could be observed in the excitable media, the neurons are often excitable within appropriate parameters. The appearance and formation of spiral wave in the cardiac tissue is linked to monomorphic ventricular tachycardia that can denervate into polymorphic tachycardia and ventricular fibrillation. The neuronal system often consists of a large number of neurons with complex connections. In this paper, we theoretically study the transition from spiral wave to spiral turbulence and homogeneous state (death of spiral wave) in two-dimensional array of the Hindmarsh-Rose neuron with completely nearest-neighbor connections. In our numerical studies, a stable rotating spiral wave is developed and selected as the initial state, then the bifurcation parameters are changed to different values to observe the transition from spiral wave to homogeneous state, breakup of spiral wave and weak change of spiral wave, respectively. A statistical factor of synchronization is defined with the mean field theory to analyze the transition from spiral wave to other spatial states, and the snapshots of the membrane potentials of all neurons and time series of mean membrane potentials of all neurons are also plotted to discuss the change of spiral wave. It is found that the sharp changing points in the curve for factor of synchronization vs. bifurcation parameter indicate sudden transition from spiral wave to other states. And the results are independent of the number of neurons we used.

  20. Design and experimental verification of low-voltage two-dimensional CMOS electrophoresis platform with 32 × 32 sample/hold cell array

    Science.gov (United States)

    Yamaji, Yuuki; Niitsu, Kiichi; Nakazato, Kazuo

    2016-03-01

    Electrophoresis is widely used in biomedical applications. However, conventional (centimeter-order) electrophoresis requires a high-voltage power supply, which is not suitable for point-of-care testing (POCT). Electrophoresis is driven by electric fields, and miniaturization (from the centimeter order to the micrometer order) is effective for low-voltage operation. A CMOS platform is a cost-competitive and promising candidate for miniaturization and enables the integration of biomolecule manipulation by electrophoresis and its electrochemical sensing. These features will contribute to the development of a biochemical analyzer called the micro-total analysis system (µ-TAS). To realize a truly portable electrophoresis system, we present the design and experimental verification of a low-voltage (<1 V), two-dimensional CMOS electrophoresis platform with 32 × 32 sample/hold cell array. Experimental results showed successful constant voltage outputs to each electrode. By miniaturizing the electrode structure to a 60 µm pitch, we achieved sufficient electric field strength even at low voltages.

  1. Electrodeposition of flake-like Cu2O on vertically aligned two-dimensional TiO2 nanosheet array films for enhanced photoelectrochemical properties

    Science.gov (United States)

    Yang, Lei; Zhang, Miao; Zhu, Kerong; Lv, Jianguo; He, Gang; Sun, Zhaoqi

    2017-01-01

    A novel Cu2O/TNS composite structure of single crystal TiO2 nanosheet (TNS) arrays decorated with flake-like Cu2O were synthesized by a facile hydrothermal reaction followed by the electrodeposition process. The effects of deposition potential on the microstructure, morphology, and optical property of the thin films were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and UV-vis spectrophotometer. When the deposition potential is higher than -0.4 V, peaks corresponding to Cu appear, meanwhile, flake-like Cu2O become agglomerating, and transform into dense Cu2O particles. Additionally, photoelectrochemical experiments indicate that the films deposited at -0.4 V show the lowest resistivity and highest exciton separation efficiency. This enhanced photoelectrochemical properties can be explained by synergistic effect of p-type flake-like Cu2O and n-type TiO2 heterojunctions combined with two-dimensional TiO2 nanosheet with exposed highly reactive {001} facets.

  2. Derivatization technique to increase the spectral selectivity of two-dimensional Fourier transform infrared focal plane array imaging: analysis of binder composition in aged oil and tempera paint.

    Science.gov (United States)

    Zumbühl, Stefan; Scherrer, Nadim C; Eggenberger, Urs

    2014-01-01

    The interpretation of standard Fourier transform infrared spectra (FT-IR) on oil-based paint samples often suffers from interfering bands of the different compounds, namely, binder, oxidative aging products, carboxylates formed during aging, and several pigments and fillers. The distinction of the aging products such as ketone and carboxylic acid functional groups pose the next problem, as these interfere with the triglyceride esters of the oil. A sample preparation and derivatization technique using gaseous sulfur tetrafluoride (SF4), was thus developed with the aim to discriminate overlapping signals and achieve a signal enhancement on superposed compounds. Of particular interest in this context is the signal elimination of the broad carboxylate bands of the typical reaction products developing during the aging processes in oil-based paints, as well as signal interference originating from several typical pigments in this spectral range. Furthermore, it is possible to distinguish the different carbonyl-containing functional groups upon selective alteration. The derivatization treatment can be applied to both microsamples and polished cross sections. It increases the selectivity of the infrared spectroscopy technique in a fundamental manner and permits the identification and two-dimensional (2D) localization of binder components in aged paint samples at the micrometer scale. The combination of SF4 derivatization with high-resolution 2D FT-IR focal plane array (FPA) imaging delivers considerable advances to the study of micro-morphological processes involving organic compounds.

  3. Composite x-ray image assembly for large-field digital mammography with one- and two-dimensional positioning of a focal plane array

    Science.gov (United States)

    Halama, G.; McAdoo, J.; Liu, H.

    1998-01-01

    To demonstrate the feasibility of a novel large-field digital mammography technique, a 1024 x 1024 pixel Loral charge-coupled device (CCD) focal plane array (FPA) was positioned in a mammographic field with one- and two-dimensional scan sequences to obtain 950 x 1800 pixel and 3600 x 3600 pixel composite images, respectively. These experiments verify that precise positioning of FPAs produced seamless composites and that the CCD mosaic concept has potential for high-resolution, large-field imaging. The proposed CCD mosaic concept resembles a checkerboard pattern with spacing left between the CCDs for the driver and readout electronics. To obtain a complete x-ray image, the mosaic must be repositioned four times, with an x-ray exposure at each position. To reduce the patient dose, a lead shield with appropriately patterned holes is placed between the x-ray source and the patient. The high-precision motorized translation stages and the fiber-coupled-scintillating-screen-CCD sensor assembly were placed in the position usually occupied by the film cassette. Because of the high mechanical precision, seamless composites were constructed from the subimages. This paper discusses the positioning, image alignment procedure, and composite image results. The paper only addresses the formation of a seamless composite image from subimages and will not consider the effects of the lead shield, multiple CCDs, or the speed of motion.

  4. 1-D array of perforated diode neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Walter J. [Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States)], E-mail: wjm4444@ksu.edu; Bellinger, Steven L.; Unruh, Troy C.; Henderson, Chris M.; Ugorowski, Phil; Morris-Lee, Bryce [Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States); Taylor, Russell D. [Electronics Design Laboratory, Kansas State University, Manhattan, KS 66506 (United States); McGregor, Douglas S. [Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States)], E-mail: mcgregor@ksu.edu

    2009-06-01

    Performance of a 4 cm long 64-pixel perforated diode neutron detector array is compared with an identical array of thin-film coated diodes. The perforated neutron detector design has been adapted to a 1-D pixel array capable of 120 {mu}m spatial resolution and counting efficiency greater than 12%. Deep vertical trenches filled with {sup 6}LiF provide outstanding improvement in efficiency over thin-film coated diode designs limited to only 4.5%. This work marks the final step towards the construction of a much larger array consisting of 1024 pixels spanning 10 cm. The larger detector array will be constructed with a sub-array of 64-pixel sensors, and will be used for small-angle neutron scattering experiments at the Spallation Neutron Source of Oak Ridge National Laboratory.

  5. Recent upgrades and performance of the CACTUS detector array

    Energy Technology Data Exchange (ETDEWEB)

    Schiller, A.; Bergholt, L.; Guttormsen, M. [and others

    1998-03-01

    The SCANDITRONIX MC-35 cyclotron laboratory, including the Oslo Cyclotron, has been in operation since 1980. The main auxiliary equipment consists of the multi-detector system CACTUS. During the last years, new, high efficiency Ge(HP) detectors were purchased and integrated in the CACTUS detector array. In this connection, the electronical setup was revised and altered. Several drawbacks of the old setup could be pointed out and eliminated. A test of the performance of all detector array elements was made with high accuracy. 27 refs.

  6. Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Chee Khoon LIEW; Kui Hian SIM; Rapaee ANNUAR; Tiong Kiam ONG; Sze Piaw CHIN; Tobias Seyfarth; Yean Yip FONG; Wei Ling CHAN; Choon Kiat ANG; Houng Bang LIEW

    2006-01-01

    Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF.

  7. Two years experience with quality assurance protocol for patient related Rapid Arc treatment plan verification using a two dimensional ionization chamber array

    Directory of Open Access Journals (Sweden)

    Vorwerk Hilke

    2011-02-01

    Full Text Available Abstract Purpose To verify the dose distribution and number of monitor units (MU for dynamic treatment techniques like volumetric modulated single arc radiation therapy - Rapid Arc - each patient treatment plan has to be verified prior to the first treatment. The purpose of this study was to develop a patient related treatment plan verification protocol using a two dimensional ionization chamber array (MatriXX, IBA, Schwarzenbruck, Germany. Method Measurements were done to determine the dependence between response of 2D ionization chamber array, beam direction, and field size. Also the reproducibility of the measurements was checked. For the patient related verifications the original patient Rapid Arc treatment plan was projected on CT dataset of the MatriXX and the dose distribution was calculated. After irradiation of the Rapid Arc verification plans measured and calculated 2D dose distributions were compared using the gamma evaluation method implemented in the measuring software OmniPro (version 1.5, IBA, Schwarzenbruck, Germany. Results The dependence between response of 2D ionization chamber array, field size and beam direction has shown a passing rate of 99% for field sizes between 7 cm × 7 cm and 24 cm × 24 cm for measurements of single arc. For smaller and larger field sizes than 7 cm × 7 cm and 24 cm × 24 cm the passing rate was less than 99%. The reproducibility was within a passing rate of 99% and 100%. The accuracy of the whole process including the uncertainty of the measuring system, treatment planning system, linear accelerator and isocentric laser system in the treatment room was acceptable for treatment plan verification using gamma criteria of 3% and 3 mm, 2D global gamma index. Conclusion It was possible to verify the 2D dose distribution and MU of Rapid Arc treatment plans using the MatriXX. The use of the MatriXX for Rapid Arc treatment plan verification in clinical routine is reasonable. The passing rate should be 99

  8. Mercury Cadmium Telluride Photoconductive Long Wave Infrared Linear Array Detectors

    Directory of Open Access Journals (Sweden)

    Risal Singh

    2003-07-01

    Full Text Available Mercury cadmium telluride (Hg1-x, CdxTe (MCT photoconductive long wave infrared linear arrays are still in demand due to several advantages. The linear array technology is well established, easier, economical and is quite relevant to thermal imaging even today. The scan thermal imaging systems based on this technology offer wider field of view coverage and capacity for higher resolution in the scan direction relative to staring systems that use expensive and yet to mature focal plane array detector technology. A critical review on photoconductive n-Hg1-x CdxTe linear array detector technology for the long wave infrared range has been presented. The emphasis lies on detector design and processing technology. The critical issues of diffusion and drift effects, Hi-Lo and heterostructure blocking contacts, surface passivation, and other related aspects have been considered from the detector design angle. The device processing technology aspects are of vital importance

  9. Hybridization of detector array and integrated circuit for readout

    Science.gov (United States)

    Fossum, Eric R.; Grunthaner, Frank J.

    1992-04-01

    A process is explained for fabricating a detector array in a layer of semiconductor material on one substrate and an integrated readout circuit in a layer of semiconductor material on a separate substrate in order to select semiconductor material for optimum performance of each structure, such as GaAs for the detector array and Si for the integrated readout circuit. The detector array layer is lifted off its substrate, laminated on the metallized surface on the integrated surface, etched with reticulating channels to the surface of the integrated circuit, and provided with interconnections between the detector array pixels and the integrated readout circuit through the channels. The adhesive material for the lamination is selected to be chemically stable to provide electrical and thermal insulation and to provide stress release between the two structures fabricated in semiconductor materials that may have different coefficients of thermal expansion.

  10. PbS-PbSe IR detector arrays

    Science.gov (United States)

    Barrett, John R. (Inventor)

    1986-01-01

    A silicon wafer is provided which does not employ individually bonded leads between the IR sensitive elements and the input stages of multiplexers. The wafer is first coated with lead selenide in a first detector array area and is thereafter coated with lead sulfide within a second detector array area. The described steps result in the direct chemical deposition of lead selenide and lead sulfide upon the silicon wafer to eliminate individual wire bonding, bumping, flip chipping, planar interconnecting methods of connecting detector array elements to silicon chip circuitry, e.g., multiplexers, to enable easy fabrication of very long arrays. The electrode structure employed, produces an increase in the electrical field gradient between the electrodes for a given volume of detector material, relative to conventional electrode configurations.

  11. Silicon PIN diode hybrid arrays for charged particle detection: Building blocks for vertex detectors at the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, G.; Gaalema, S.; Shapiro, S.L.; Dunwoodie, W.M.; Arens, J.F.; Jernigan, J.G.

    1989-05-01

    Two-dimensional arrays of solid state detectors have long been used in visible and infrared systems. Hybrid arrays with separately optimized detector and readout substrates have been extensively developed for infrared sensors. The characteristics and use of these infrared readout chips with silicon PIN diode arrays produced by MICRON SEMICONDUCTOR for detecting high-energy particles are reported. Some of these arrays have been produced in formats as large as 512 /times/ 512 pixels; others have been radiation hardened to total dose levels beyond 1 Mrad. Data generation rates of 380 megasamples/second have been achieved. Analog and digital signal transmission and processing techniques have also been developed to accept and reduce these high data rates. 9 refs., 15 figs., 2 tabs.

  12. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    A Chatterjee; Sushil Kamerkar; A K Jethra; S Padmini; M P Diwakar; S S Pande; M D Ghodgaonkar

    2001-07-01

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

  13. Particle Identification in the NIMROD-ISiS Detector Array

    CERN Document Server

    Wuenschel, S; May, L W; Wada, R; Yennello, S J

    2009-01-01

    Interest in the influence of the neutron-to-proton (N/Z) ratio on multifragmenting nuclei has demanded an improvement in the capabilities of multi-detector arrays as well as the companion analysis methods. The particle identification method used in the NIMROD-ISiS 4 $\\pi$ array is described. Performance of the detectors and the analysis method are presented for the reaction of 86Kr+64Ni at 35MeV/u.

  14. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

    Science.gov (United States)

    Brualla-González, Luis; Gómez, Faustino; Vicedo, Aurora; González-Castaño, Diego M; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Roselló, Joan V; Pardo-Montero, Juan

    2012-08-21

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development.

  15. The surface detector array of the Telescope Array experiment to explore the highest energy cosmic rays

    CERN Document Server

    Abu-Zayyad, T; Allen, M; Anderson, R; Azuma, R; Barcikowski, E; Belz, J W; Bergman, D R; Blake, S A; Cady, R; Cheon, B G; Chiba, J; Chikawa, M; Cho, E J; Cho, W R; Fujii, H; Fujii, T; Fukuda, T; Fukushima, M; Gorbunov, D; Hanlon, W; Hayashi, K; Hayashi, Y; Hayashida, N; Hibino, K; Hiyama, K; Honda, K; Iguchi, T; Ikeda, D; Ikuta, K; Inoue, N; Ishii, T; Ishimori, R; Ivanov, D; Iwamoto, S; Jui, C C H; Kadota, K; Kakimoto, F; Kalashev, O; Kanbe, T; Kasahara, K; Kawai, H; Kawakami, S; Kawana, S; Kido, E; Kim, H B; Kim, H K; Kim, J H; Kim, J H; Kitamoto, K; Kobayashi, K; Kobayashi, Y; Kondo, Y; Kuramoto, K; Kuzmin, V; Kwon, Y J; Lim, S I; Machida, S; Martens, K; Martineau, J; Matsuda, T; Matsuura, T; Matsuyama, T; Matthews, J N; Myers, I; Minamino, M; Miyata, K; Miyauchi, H; Murano, Y; Nakamura, T; Nam, S W; Nonaka, T; Ogio, S; Ohnishi, M; Ohoka, H; Oki, K; Oku, D; Okuda, T; Oshima, A; Ozawa, S; Park, I H; Pshirkov, M S; Rodriguez, D; Roh, S Y; Rubtsov, G; Ryu, D; Sagawa, H; Sakurai, N; Sampson, A L; Scott, L M; Shah, P D; Shibata, F; Shibata, T; Shimodaira, H; Shin, B K; Shin, J I; Shirahama, T; Smith, J D; Sokolsky, P; Sonley, T J; Springer, R W; Stokes, B T; Stratton, S R; Stroman, T A; Suzuki, S; Takahashi, Y; Takeda, M; Taketa, A; Takita, M; Tameda, Y; Tanaka, H; Tanaka, K; Tanaka, M; Thomas, S B; Thomson, G B; Tinyakov, P; Tkachev, I; Tokuno, H; Tomida, T; Troitsky, S; Tsunesada, Y; Tsutsumi, K; Tsuyuguchi, Y; Uchihori, Y; Udo, S; Ukai, H; Vasiloff, G; Wada, Y; Wong, T; Wood, M; Yamakawa, Y; Yamaoka, H; Yamazaki, K; Yang, J; Yoshida, S; Yoshii, H; Zollinger, R; Zundel, Z

    2012-01-01

    The Telescope Array (TA) experiment, located in the western desert of Utah,USA, is designed for observation of extensive air showers from extremely high energy cosmic rays. The experiment has a surface detector array surrounded by three fluorescence detectors to enable simultaneous detection of shower particles at ground level and fluorescence photons along the shower track. The TA surface detectors and fluorescence detectors started full hybrid observation in March, 2008. In this article we describe the design and technical features of the TA surface detector.

  16. An integrated single photon detector array using porous anodic alumina

    NARCIS (Netherlands)

    Melai, J.; Salm, C.; Schmitz, J.; Smits, S.M.; Visschers, J.L.

    2006-01-01

    The aim of the work is fabrication of a photon detector array made using IC compatible wafer-scale post-processing stepts. Plans will be presented to outline these fabrication steps. The detector comprises an integrated Micro-Channel-Plate and an imaging chip like Medipix2. The aim of the work is fa

  17. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    Science.gov (United States)

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A Study on the New Two-Dimensional Hall Angular Detector%一种新型两维霍尔角度传感器研究

    Institute of Scientific and Technical Information of China (English)

    赖宗声; 蔡彦; 景圳; 贺德洪; 郑筱莉

    2001-01-01

    A new contactless two-dimensional integrated Hall Angular Detector was presented. A radial permanent magnet is attached to the axis whose angle position α is to be determined. Two orthogonal vertical Hall devices in cross shape, which active sensing area is 150μm×150 μm, measure the magnetic field X,Y components paralled to the chip surface and therefore the angular position α of the axis. When the permanent magnet was rotating, the measured output voltages V\\-x,V\\-y by the two pairs of vertical Hall plates were changed correspondingly. The angle α could be obtained by calculating the arc tangent of the signal ratio V\\-X/V\\-Y through the software and PC processor. The experimental results show an angular measurement accuracy of ±1° over a full 360° operating range.%本文研制了一种无触点的十字型两维集成垂直霍尔器件,它对平行于芯片表面的磁场敏感.当与被测转角α的物件轴向相固连的径向永久磁铁转动时,平行于芯片表面的磁场分量B\\-x、B\\-y大小将发生相对变化,以致集成的两对霍尔板输出电量也产生相应地变化.这时传感器件给出了相对于被测量角度α的两种信号电压(sinα和cosα),通过arctgn(V\\-x/V\\-y)可求得转角α,从而达到测量角度的目的.测量结果表明利用该角度传感器件与PC机组成的测量系统其测量角度的精度可达±1°.

  19. A liquid core waveguide fluorescence detector for multicapillary electrophoresis applied to DNA sequencing in a 91-capillary array.

    Science.gov (United States)

    Hanning, A; Westberg, J; Roeraade, J

    2000-09-01

    A new laser-induced fluorescence (LIF) detector for multicapillary electrophoresis is presented. The detection principle is based on waveguiding of the emitted fluorescence from the point of illumination to the capillary ends by total internal reflection (TIR) and imaging of the capillary ends. The capillaries themselves thus act as liquid core waveguides (LCWs). At the illumination point, the capillaries are arranged in a planar array, which allows clean and efficient illumination with a line-focused laser beam. The capillary ends are rearranged into a small, densely packed two-dimensional array, which is imaged end-on with high light collection efficiency and excellent image quality. Wavelength dispersion is obtained with a single prism. Intercapillary optical crosstalk is less than 0.5%, and rejection of stray light is very efficient. The detector is applied to four-color DNA sequencing by gel electrophoresis in a 91-capillary array, with simple fluorescein and rhodamine dyes as fluorophores. Since the imaged two-dimensional array is so compact, the detector has a high potential for very large-scale multiplexing.

  20. New air fluorescence detectors employed in the Telescope Array experiment

    CERN Document Server

    Tokuno, H; Takeda, M; Kadota, K; Ikeda, D; Chikawa, M; Fujii, T; Fukushima, M; Honda, K; Inoue, N; Kakimoto, F; Kawana, S; Kido, E; Matthews, J N; Nonaka, T; Ogio, S; Okuda, T; Ozawa, S; Sagawa, H; Sakurai, N; Shibata, T; Taketa, A; Thomas, S B; Tomida, T; Tsunesada, Y; Udo, S; Abu-zayyad, T; Aida, R; Allen, M; Anderson, R; Azuma, R; Barcikowski, E; Belz, J W; Bergman, D R; Blake, S A; Cady, R; Cheon, B G; Chiba, J; Cho, E J; Cho, W R; Fujii, H; Fukuda, T; Gorbunov, D; Hanlon, W; Hayashi, K; Hayashi, Y; Hayashida, N; Hibino, K; Hiyama, K; Iguchi, T; Ikuta, K; Ishii, T; Ishimori, R; Ivanov, D; Iwamoto, S; Jui, C C H; Kalashev, O; Kanbe, T; Kasahara, K; Kawai, H; Kawakami, S; Kim, H B; Kim, H K; Kim, J H; Kim, J H; Kitamoto, K; Kobayashi, K; Kobayashi, Y; Kondo, Y; Kuramoto, K; Kuzmin, V; Kwon, Y J; Lim, S I; Machida, S; Martens, K; Martineau, J; Matsuda, T; Matsuura, T; Matsuyama, T; Myers, I; Minamino, M; Miyata, K; Miyauchi, H; Murano, Y; Nakamura, T; Nam, S W; Ohnishi, M; Ohoka, H; Oki, K; Oku, D; Oshima, A; Park, I H; Pshirkov, M S; Rodriguez, D; Roh, S Y; Rubtsov, G; Ryu, D; Sampson, A L; Scott, L M; Shah, P D; Shibata, F; Shimodaira, H; Shin, B K; Shin, J I; Shirahama, T; Smith, J D; Sokolsky, P; Sonley, T J; Springer, R W; Stokes, B T; Stratton, S R; Stroman, T; Suzuki, S; Takahashi, Y; Takita, M; Tanaka, H; Tanaka, K; Tanaka, M; Thomson, G B; Tinyakov, P; Tkachev, I; Troitsky, S; Tsutsumi, K; Tsuyuguchi, Y; Uchihori, Y; Ukai, H; Vasiloff, G; Wada, Y; Wong, T; Wood, M; Yamakawa, Y; Yamaoka, H; Yamazaki, K; Yang, J; Yoshida, S; Yoshii, H; Zollinger, R; Zundel, Z

    2012-01-01

    Since 2007, the Telescope Array (TA) experiment, based in Utah, USA, has been observing ultra high energy cosmic rays to understand their origins. The experiment involves a surface detector (SD) array and three fluorescence detector (FD) stations. FD stations, installed surrounding the SD array, measure the air fluorescence light emitted from extensive air showers (EASs) for precise determination of their energies and species. The detectors employed at one of the three FD stations were relocated from the High Resolution Fly's Eye experiment. At the other two stations, newly designed detectors were constructed for the TA experiment. An FD consists of a primary mirror and a camera equipped with photomultiplier tubes. To obtain the EAS parameters with high accuracies, understanding the FD optical characteristics is important. In this paper, we report the characteristics and installation of new FDs and the performances of the FD components. The results of the monitored mirror reflectance during the observation ti...

  1. A Study of Lane Differentiation Using An Array of Detectors.

    Energy Technology Data Exchange (ETDEWEB)

    McKigney E. A. (Edward A.); Gholkar, R. V. (Rohun V.); Vega, D. A. (Daniel A.)

    2004-01-01

    The authors discuss a method for locating a radioactive source in the context of determining which lane a source is in on a roadway. This method is appropriate for use over a large range of source velocities, and could provide an advance alarm prior to a vehicle passing a portal monitor. This is a novel method which uses data from the entire array simultaneously to locate the source, rather than relying on only one or two sensors. A description of the underlying method will be given, along with results from five and six detector arrays. The five detector array was used mainly for static tests. The six detector array was used for dynamic tests, including slow movement of a source in a vehicle.

  2. Nanorod Array Solid State Neutron Detectors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I SBIR project, Synkera proposes to develop and commercialize solid-state neutron detectors of a unique architecture that will enable sensor modules...

  3. Bolometeric detector arrays for CMB polarimetry

    Science.gov (United States)

    Kuo, C. L.; Bock, J. J.; Day, P.; Goldin, A.; Golwala, S.; Holmes, W.; Irwin, K.; Kenyon, M.; Lange, A. E.; LeDuc, H. G.; Rossinot, P.; Sterb, J.; Vayonakis, A.; Wang, G.; Yun, M.; Zmuidzinas, J.

    2005-01-01

    We describe the development of antenna coupled bolometers for CMB polarization experiments. The necessary components of a bolometric CMB polarimeter - a beam forming element, a band defining filter, and detectors - are all fabricated on a silicon chip with photolithography.

  4. Surface detector array for the Pierre Auger observatory

    Science.gov (United States)

    Salazar, H.; Garipov, G. K.; Khrenov, B. A.; Martínez, O.; Moreno, E.; Villaseñor, L.; Zepeda, A.

    2001-05-01

    The Pierre Auger international collaboration will install two observatories, one in the southern hemisphere and other in the northern hemisphere. Each observatory will consist of two different subsystem: a surface detector array of about 1600 water Cherenkov detectors (WCD) and a set of fluorescence eyes to measure the longitudinal development of air showers. The large area covered by the surface detectors requires efficient calibration and monitoring methods that can be implemented remotely. We present several complementary methods to calibrate and monitor the performance of the individual surface detector stations. We also present some results of the studies made with a full size prototype tank in Puebla, Mexico and in Malargue, Argentina. .

  5. Research of High Sensitivity Uncooled Infrared Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Pingchuan [Huazhong University of Science and Technology, Wuhan 430074 (China); Zhang, Bo, E-mail: redmoon123456@126.com, E-mail: lhzyzb@126.com [Luohe Vocational Technology College, Luohe 462002 (China)

    2011-02-01

    The infrared thermal imaging technology has been widely used in military and civilian fields and the field of the infrared detection and infrared thermal imaging technology has been of concern for a long time. On infrared thermal imaging, its core components for the infrared focal plane arrays, how to develop a high sensitivity of the multi-focal plane infrared detector is a key issue. Although the Common focal plane array of quantum has high sensitivity, but it requires low temperature cooling work environment and led to complexity and high cost, difficult to compact. Conventional uncooled infrared focal plane array is contrast to the quantum focal plane arrays. Therefore, this article preceded by the uncooled infrared detector array to improve the wide temperature sensitivity in examining the feasibility PMN composite film, materials composition, structure design and preparation process technology.

  6. Monte Carlo simulation of a single detector unit for the neutron detector array NEDA

    Energy Technology Data Exchange (ETDEWEB)

    Jaworski, G. [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa (Poland); Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, PL 02-093 Warszawa (Poland); Palacz, M., E-mail: palacz@slcj.uw.edu.pl [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, PL 02-093 Warszawa (Poland); Nyberg, J. [Department of Physics and Astronomy, Uppsala University, Uppsala (Sweden); Angelis, G. de [INFN, Laboratori Nazionali di Legnaro, Legnaro (Italy); France, G. de [GANIL, Caen (France); Di Nitto, A. [INFN Sezione di Napoli, Napoli (Italy); Egea, J. [Department of Electronic Engineering, University of Valencia, Burjassot (Valencia) (Spain); IFIC-CSIC, University of Valencia, Valencia (Spain); Erduran, M.N. [Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University Istanbul (Turkey); Ertuerk, S. [Nigde Universitesi, Fen-Edebiyat Falkueltesi, Fizik Boeluemue, Nigde (Turkey); Farnea, E. [INFN Sezione di Padova, Padua (Italy); Gadea, A. [IFIC-CSIC, University of Valencia, Valencia (Spain); Gonzalez, V. [Department of Electronic Engineering, University of Valencia, Burjassot (Valencia) (Spain); Gottardo, A. [Padova University, Padua (Italy); Hueyuek, T. [IFIC-CSIC, University of Valencia, Valencia (Spain); Kownacki, J. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, PL 02-093 Warszawa (Poland); Pipidis, A. [INFN, Laboratori Nazionali di Legnaro, Legnaro (Italy); Roeder, B. [LPC-Caen, ENSICAEN, IN2P3/CNRS et Universite de Caen, Caen (France); Soederstroem, P.-A. [Department of Physics and Astronomy, Uppsala University, Uppsala (Sweden); Sanchis, E. [Department of Electronic Engineering, University of Valencia, Burjassot (Valencia) (Spain); Tarnowski, R. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, PL 02-093 Warszawa (Poland); and others

    2012-05-01

    A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.

  7. AIGO: a southern hemisphere detector for the worldwide array of ground-based interferometric gravitational wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Barriga, P; Blair, D G; Coward, D; Davidson, J; Dumas, J-C; Howell, E; Ju, L; Wen, L; Zhao, C [School of Physics, The University of Western Australia, Crawley, WA 6009 (Australia); McClelland, D E; Scott, S M; Slagmolen, B J J; Inta, R [Department of Physics, Faculty of Science, Australian National University, Canberra, ACT 0200 (Australia); Munch, J; Ottaway, D J; Veitch, P; Hosken, D [Department of Physics, University of Adelaide, Adelaide, SA 5005 (Australia); Melatos, A; Chung, C; Sammut, L, E-mail: pbarriga@cyllene.uwa.edu.a [School of Physics University of Melbourne, Parkville, Vic 3010 (Australia)

    2010-04-21

    This paper describes the proposed AIGO detector for the worldwide array of interferometric gravitational wave detectors. The first part of the paper summarizes the benefits that AIGO provides to the worldwide array of detectors. The second part gives a technical description of the detector, which will follow closely the Advanced LIGO design. Possible technical variations in the design are discussed.

  8. The Detector Calibration System for the CUORE cryogenic bolometer array

    CERN Document Server

    Cushman, J S; Davis, C J; Ejzak, L; Lenz, D; Lim, K E; Heeger, K M; Maruyama, R H; Nucciotti, A; Sangiorgio, S; Wise, T

    2016-01-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of $^{130}$Te and other rare events. The CUORE detector consists of 988 TeO$_2$ bolometers operated underground at 10~mK in a dilution refrigerator at the Laboratori Nazionali del Gran Sasso. Candidate events are identified through a precise measurement of their energy. The absolute energy response of the detectors is established by the regular calibration of each individual bolometer using gamma sources. The close-packed configuration of the CUORE bolometer array combined with the extensive shielding surrounding the detectors requires the placement of calibration sources within the array itself. The CUORE Detector Calibration System is designed to insert radioactive sources into and remove them from the cryostat while respecting the stringent heat load, radiopurity, and operational requirements of the experiment. This paper describes the design, commissioning...

  9. Neutron detector array at IUAC: Design features and instrumentation developments

    Indian Academy of Sciences (India)

    P Sugathan; A Jhingan; K S Golda; T Varughese; S Venkataramanan; N Saneesh; V V Satyanarayana; S K Suman; J Antony; Ruby Shanti; K Singh; S K Saini; A Gupta; A Kothari; P Barua; Rajesh Kumar; J Zacharias; R P Singh; B R Behera; S K Mandal; I M Govil; R K Bhowmik

    2014-11-01

    The characteristics and performance of the newly commissioned neutron detector array at IUAC are described. The array consists of 100 BC501 liquid scintillators mounted in a semispherical geometry and are kept at a distance of 175 cm from the reaction point. Each detector is a 5″ × 5″ cylindrical cell coupled to 5″ diameter photomultiplier tube (PMT). Signal processing is realized using custom-designed home-made integrated electronic modules which perform neutron–gamma discrimination using zero cross timing and time-of-flight (TOF) technique. Compact custom-built high voltage power supply developed using DC–DC converters are used to bias the detector. The neutrons are recorded in coincidence with fission fragments which are detected using multi-wire proportional counters mounted inside a 1m diameter SS target chamber. The detectors and electronics have been tested off-line using radioactive sources and the results are presented.

  10. High-energy interactions in Kinetic Inductance Detectors arrays

    CERN Document Server

    D'Addabbo, A; Goupy, J; Benoit, A; Bourrion, O; Catalano, A; Macias-Perez, J F; Monfardini, A

    2015-01-01

    The impacts of Cosmic Rays on the detectors are a key problem for space-based missions. We are studying the effects of such interactions on arrays of Kinetic Inductance Detectors (KID), in order to adapt this technology for use on board of satellites. Before proposing a new technology such as the Kinetic Inductance Detectors for a space-based mission, the problem of the Cosmic Rays that hit the detectors during in-flight operation has to be studied in detail. We present here several tests carried out with KID exposed to radioactive sources, which we use to reproduce the physical interactions induced by primary Cosmic Rays, and we report the results obtained adopting different solutions in terms of substrate materials and array geometries. We conclude by outlining the main guidelines to follow for fabricating KID for space-based applications.

  11. Integrated Miniature Arrays of Optical Biomolecule Detectors

    Science.gov (United States)

    Iltchenko, Vladimir; Maleki, Lute; Lin, Ying; Le, Thanh

    2009-01-01

    Integrated miniature planar arrays of optical sensors for detecting specific biochemicals in extremely small quantities have been proposed. An array of this type would have an area of about 1 cm2. Each element of the array would include an optical microresonator that would have a high value of the resonance quality factor (Q . 107). The surface of each microresonator would be derivatized to make it bind molecules of a species of interest, and such binding would introduce a measurable change in the optical properties of the microresonator. Because each microresonator could be derivatized for detection of a specific biochemical different from those of the other microresonators, it would be possible to detect multiple specific biochemicals by simultaneous or sequential interrogation of all the elements in the array. Moreover, the derivatization would make it unnecessary to prepare samples by chemical tagging. Such interrogation would be effected by means of a grid of row and column polymer-based optical waveguides that would be integral parts of a chip on which the array would be fabricated. The row and column polymer-based optical waveguides would intersect at the elements of the array (see figure). At each intersection, the row and column waveguides would be optically coupled to one of the microresonators. The polymer-based waveguides would be connected via optical fibers to external light sources and photodetectors. One set of waveguides and fibers (e.g., the row waveguides and fibers) would couple light from the sources to the resonators; the other set of waveguides and fibers (e.g., the column waveguides and fibers) would couple light from the microresonators to the photodetectors. Each microresonator could be addressed individually by row and column for measurement of its optical transmission. Optionally, the chip could be fabricated so that each microresonator would lie inside a microwell, into which a microscopic liquid sample could be dispensed.

  12. Conference on physics from large {gamma}-ray detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    The conference on {open_quotes}Physics from Large {gamma}-ray Detector Arrays{close_quotes} is a continuation of the series of conferences that have been organized every two years by the North American Heavy-ion Laboratories. The aim of the conference this year was to encourage discussion of the physics that can be studied with such large arrays. This volume is the collected proceedings from this conference. It discusses properties of nuclear states which can be created in heavy-ion reactions, and which can be observed via such detector systems.

  13. Detectors based on silicon photomultiplier arrays for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Llosa, G.; Barrio, J.; Cabello, J.; Lacasta, C.; Oliver, J. F. [Instituto de Fisica Corpuscular - IFIC-CSIC/UVEG, Valencia (Spain); Rafecas, M. [Instituto de Fisica Corpuscular - IFIC-CSIC/UVEG, Valencia (Spain); Departamento de Fisica Atomica, Molecular Y Nuclear, Universitat de Valencia, Valencia (Spain); Stankova, V.; Solaz, C. [Instituto de Fisica Corpuscular - IFIC-CSIC/UVEG, Valencia (Spain); Bisogni, M. G.; Del Guerra, A. [Universite di Pisa, INFN Pisa, Pisa (Italy)

    2011-07-01

    Silicon photomultipliers (SiPMs) have experienced a fast development and are now employed in different research fields. The availability of 2D arrays that provide information of the interaction position in the detector has had a high interest for medical imaging. Continuous crystals combined with segmented photodetectors can provide higher efficiency than pixellated crystals and very high spatial resolution. The IRIS group at IFIC is working on the development of detector heads based on continuous crystals coupled to SiPM arrays for different applications, including a small animal PET scanner in collaboration with the Univ. of Pisa and INFN Pisa, and a Compton telescope for dose monitoring in hadron therapy. (authors)

  14. L型阵列的二维DOA估计方法%Method of two-dimensional DOA estimation for L-shaped array

    Institute of Scientific and Technical Information of China (English)

    景小荣; 刘雪峰

    2016-01-01

    低信噪比(signal-to-noise ratio,SNR)或小接收快拍数条件下,经典的二维(two-dimensional,2D)波达方向(direction of arrival,DOA)算法存在估计精度低的缺点。针对该问题,充分利用 L 型阵列接收数据的自、互相关信息,提出一种适用于低 SNR 及小接收快拍数环境下的2D DOA 估计新方法。该方法首先通过解析优化2D 谱峰搜索问题,获得方位角与仰角之间的特定约束关系,进而将包含2D 角度参量的目标函数转化为只包含一维(one-di-mensional,1 D)角度参量,即可通过1 D 谱峰搜索获得方位角(或仰角)估计值,最后再次利用该约束关系求得与之对应的仰角(或方位角)估计值。该方法只需1 D 谱峰搜索,而且所得2D 角度估计参数可自动实现配对。计算机仿真验证了该方法在低 SNR 及小接收快拍数情况下的有效性。%Under low SNR region or with the small number of the snapshots,the classic two-dimensional (2D)direction-of-arrival (DOA)algorithms have the drawback of low estimation accuracy.To resolve the problem,the paper presents a new method of 2D DOA estimation suitable for low signal-to-noise (SNR)region and small number of the snapshots by fully tak-ing advantage of the autocorrelation and cross-correlation information of the received snapshots of L-shape sensor arrays. Analytically optimizing the problem of 2D spectrum peak search,we obtain the specific constraint relationship between the azimuth and elevation.On the basis of it,the method firstly converts the objective function with 2D angle parameter into the one with one-dimensional (1 D)angle parameter.Then the azimuth (or elevation)is obtained by 1 D searching.Finally, the elevation (or azimuth)can be estimated according to the specific constraint relationship between the azimuth and eleva-tion.The method only needs 1 D spectrum peak searching,and the estimated azimuth and elevation can be

  15. FFTS readout for large arrays of Microwave Kinetic Inductance Detectors

    CERN Document Server

    Yates, S J C; Baselmans, J J A; Klein, B; Güsten, R

    2009-01-01

    Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of Fast Fourier Transform Spectrometer (FFTS) readout, showing no deterioration of the noise performance compared to low noise analog mixing while allowing high multiplexing ratios.

  16. Advanced ACTPol Cryogenic Detector Arrays and Readout

    CERN Document Server

    Henderson, S W; Austermann, J; Baildon, T; Battaglia, N; Beall, J A; Becker, D; De Bernardis, F; Bond, J R; Calabrese, E; Choi, S K; Coughlin, K P; Crowley, K T; Datta, R; Devlin, M J; Duff, S M; Dunner, R; Dunkley, J; van Engelen, A; Gallardo, P A; Grace, E; Hasselfield, M; Hills, F; Hilton, G C; Hincks, A D; Hlozek, R; Ho, S P; Hubmayr, J; Huffenberger, K; Hughes, J P; Irwin, K D; Koopman, B J; Kosowsky, A B; Li, D; McMahon, J; Munson, C; Nati, F; Newburgh, L; Niemack, M D; Niraula, P; Page, L A; Pappas, C G; Salatino, M; Schillaci, A; Schmitt, B L; Sehgal, N; Sherwin, B D; Sievers, J L; Simon, S M; Spergel, D N; Staggs, S T; Stevens, J R; Thornton, R; Van Lanen, J; Vavagiakis, E M; Ward, J T; Wollack, E J

    2015-01-01

    Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope (ACT), adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background (CMB) anisotropies -- imaged in intensity and polarization at few arcminute-scale resolution -- will enable precision cosmological constraints and also a wide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the Advanced ACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor (TES) polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new ...

  17. A readout for large arrays of microwave kinetic inductance detectors.

    Science.gov (United States)

    McHugh, Sean; Mazin, Benjamin A; Serfass, Bruno; Meeker, Seth; O'Brien, Kieran; Duan, Ran; Raffanti, Rick; Werthimer, Dan

    2012-04-01

    Microwave kinetic inductance detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at microwave frequencies, allowing the construction and readout of large arrays. Due to the microwave FDM, MKIDs do not require the complex cryogenic multiplexing electronics used for similar detectors, such as transition edge sensors, but instead transfer this complexity to room temperature electronics where they present a formidable signal processing challenge. In this paper, we describe the first successful effort to build a readout for a photon counting optical/near-IR astronomical instrument, the ARray Camera for Optical to Near-infrared Spectrophotometry. This readout is based on open source hardware developed by the Collaboration for Astronomy Signal Processing and Electronics Research. Designed principally for radio telescope backends, it is flexible enough to be used for a variety of signal processing applications.

  18. A readout for large arrays of Microwave Kinetic Inductance Detectors

    CERN Document Server

    McHugh, Sean; Serfass, Bruno; Meeker, Seth; O'Brien, Kieran; Duan, Ran; Raffanti, Rick; Werthimer, Dan

    2012-01-01

    Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at microwave frequencies, allowing the construction and readout of large arrays. Due to the microwave FDM, MKIDs do not require the complex cryogenic multiplexing electronics used for similar detectors, such as Transition Edge Sensors (TESs), but instead transfer this complexity to room temperature electronics where they present a formidable signal processing challenge. In this paper we describe the first successful effort to build a readout for a photon counting optical/near-IR astronomical instrument, the ARray Camera for Optical to Near-infrared Spectrophotometry (ARCONS). This readout is based on open source hardware developed by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER). Designed principally for radio telescope backends, it is flexible...

  19. Installation and Operation of the SNO Neutral Current Detector Array

    Science.gov (United States)

    SNO Collaboration; McGee, S.; Rielage, K.

    2005-06-01

    An array of low background detectors designed to capture neutrons liberated by interactions with solar neutrinos was recently installed in the heavy water region of the SNO experiment. The neutral current detector (NCD) array consists of 36 proportional counters filled with 3He-CF4 gas and 4 proportional counters filled with 4He-CF4. Special hardware conforming to the high radiopurity requirements in SNO was used to assemble and deploy these counters. Neutron events detected by the NCD array are distinguished from various types of backgrounds on an event-by-event basis using the NCD data acquisition system (NCDDAQ), which employs a mixture of commercial and custom-built electronics equipment. The NCDDAQ is controlled by a custom-built Object-oriented Realtime Control and Acquisition (ORCA) software program, and is fully integrated into the SNO PMT data acquisition system to provide shared trigger information and a combined data stream.

  20. Installation and Operation of the SNO Neutral Current Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Heise, J. [Physics Division, Los Alamos National Laboratory, Los Alamos, NM, 87545 (United States); McGee, S. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA, 98195 (United States); Rielage, K. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA, 98195 (United States)

    2005-06-15

    An array of low background detectors designed to capture neutrons liberated by interactions with solar neutrinos was recently installed in the heavy water region of the SNO experiment. The neutral current detector (NCD) array consists of 36 proportional counters filled with {sup 3}He-CF{sub 4} gas and 4 proportional counters filled with {sup 4}He-CF{sub 4}. Special hardware conforming to the high radiopurity requirements in SNO was used to assemble and deploy these counters. Neutron events detected by the NCD array are distinguished from various types of backgrounds on an event-by-event basis using the NCD data acquisition system (NCDDAQ), which employs a mixture of commercial and custom-built electronics equipment. The NCDDAQ is controlled by a custom-built Object-oriented Realtime Control and Acquisition (ORCA) software program, and is fully integrated into the SNO PMT data acquisition system to provide shared trigger information and a combined data stream.

  1. Prototype imaging Cd-Zn-Te array detector

    Energy Technology Data Exchange (ETDEWEB)

    Bloser, P.F.; Narita, T.; Grindlay, J.E. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Shah, K. [Radiation Monitoring Devices, Inc., Watertown, MA (United States)

    1998-12-31

    The authors describe initial results of their program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Their primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range {approximately}10--600 keV. The coded aperture imaging configuration requires only relatively large area pixels (1--3 mm), whereas the desired high energy response requires detector thicknesses of at least 3--5 mm. They have developed a prototype detector employing a 10 x 10 x 5 mm CZT substrate and 4 x 4 pixel (1.5 mm each) readout with gold metal contacts for the pixels and continuous gold contact for the bias on the opposite detector face. This MSM contact configuration was fabricated by RMD and tested at Harvard for uniformity, efficiency and spatial as well as spectral resolution. The authors have developed an ASIC readout (IDE-VA-1) and analysis system and report results, including {approximately}4% (FWHM) energy resolution at 60 keV. A prototype design for a full imaging detector array is discussed.

  2. State of the art of AIM LWIR and VLWIR MCT 2D focal plane detector arrays for higher operating temperatures

    Science.gov (United States)

    Figgemeier, H.; Hanna, S.; Eich, D.; Mahlein, K.-M.; Fick, W.; Schirmacher, W.; Thöt, R.

    2016-05-01

    In this paper AIM presents its latest results on both n-on-p and p-on-n low dark current planar MCT photodiode technology LWIR and VLWIR two-dimensional focal plane detector arrays with a cut-off wavelength >11μm at 80K and a 640x512 pixel format at a 20μm pitch. Thermal dark currents significantly reduced as compared to `Tennant's Rule 07' at a yet good detection efficiency >60% as well as results from NETD and photo response performance characterization are presented. The demonstrated detector performance paces the way for a new generation of higher operating temperature LWIR MCT FPAs with a <30mK NETD up to a 110K detector operating temperature and with good operability.

  3. Faraday cup detector array with electronic multiplexing for multichannel mass spectrometry

    CERN Document Server

    Scheidemann, A A; Schumacher, F J; Isakharov, A

    2002-01-01

    A Faraday cup detector array (FCDA) and electronic multiplexing circuit have been developed for position sensitive ion beam detection. The entire FCDA always remains open to intercept the incident ion beam flux, and each cup is periodically and sequentially discharged through the electronic multiplexer. This produces true multichannel ion beam detection since none of the incident ion beam flux is lost, as is the case for scanning position sensitive detectors, and higher sensitivity detection is thus obtained. The FCDA consists of a one-dimensional or two-dimensional array of individual cups which are electrostatically isolated from each other by means of an intervening ground conductor, with resulting fill factors F of 58% to 85%. Each cup acts as a charge collector and integrator which is quickly discharged during the readout to create a time-multiplexed output signal that gives the position distribution of the ion beam. When N cups are sequentially scanned and read out, the ion collection efficiency is F(1-...

  4. Very Large Scale Integration of Nano-Patterned YBa2Cu3O7-delta Josephson Junctions in a Two-Dimensional Array

    Science.gov (United States)

    2010-03-26

    suggested that it may be possible to use incommensurate area SQUID arrays as radio frequency ( RF ) amplifiers.32 3 Shane A. Cybart et al. The layout of...our array is shown in Figure 1. For efficient coupling of RF in future experiments we chose a microstrip line configuration with SQUID loops cut into...variations of the process to reproduce single junctions,20–24 series arrays of tens of junctions,25,26 and a series array of 280 SQUIDs .27 Here we report

  5. New air fluorescence detectors employed in the Telescope Array experiment

    Energy Technology Data Exchange (ETDEWEB)

    Tokuno, H., E-mail: htokuno@cr.phys.titech.ac.jp [Tokyo Institute of Technology, Meguro, Tokyo (Japan); Tameda, Y.; Takeda, M. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); Kadota, K. [Tokyo City University, Setagaya-ku, Tokyo (Japan); Ikeda, D. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); Chikawa, M. [Kinki University, Higashi Osaka, Osaka (Japan); Fujii, T. [Osaka City University, Osaka, Osaka (Japan); Fukushima, M. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); University of Tokyo, Institute for the Physics and Mathematics of the Universe, Kashiwa, Chiba (Japan); Honda, K. [University of Yamanashi, Interdisciplinary Graduate School of Medicine and Engineering, Kofu, Yamanashi (Japan); Inoue, N. [Saitama University, Saitama, Saitama (Japan); Kakimoto, F. [Tokyo Institute of Technology, Meguro, Tokyo (Japan); Kawana, S. [Saitama University, Saitama, Saitama (Japan); Kido, E. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); Matthews, J.N. [University of Utah, High Energy Astrophysics Institute, Salt Lake City, Utah (United States); Nonaka, T. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); Ogio, S.; Okuda, S. [Osaka City University, Osaka, Osaka (Japan); Ozawa, S. [Waseda University, Advanced Research Institute for Science and Engineering, Shinjuku-ku, Tokyo (Japan); Sagawa, H. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba (Japan); Sakurai, N. [Osaka City University, Osaka, Osaka (Japan); and others

    2012-06-01

    Since 2007, the Telescope Array (TA) experiment, based in Utah, USA, has been observing ultra high energy cosmic rays to understand their origins. The experiment includes a surface detector (SD) array and three fluorescence detector (FD) stations. The FD stations, installed surrounding the SD array, measure the air fluorescence light emitted from extensive air showers (EASs) for precise determination of their energies and species. The detectors employed at one of the three FD stations were relocated from the High Resolution Fly's Eye (HiRes) experiment. At the other two stations, newly designed detectors were constructed for the TA experiment. An FD consists of a primary mirror and a camera equipped with photomultiplier tube pixels. To obtain the EAS parameters with high accuracy, understanding the FD optical characteristics is important. In this paper, we report the characteristics and installation of the new FDs and the performances of the FD components. The results of the monitored mirror reflectance during the observation time are also described in this report.

  6. A Sub-pixel Image Processing Algorithm of a Detector Based on Staring Focal Plane Array

    Institute of Scientific and Technical Information of China (English)

    LI Ya-qiong; JIN Wei-qi; XU Chao; WANG Xia

    2008-01-01

    Optical micro-scanning technology can be used to increase spatial resolution of many optical imaging systems, especially thermal imaging system. One of its key issues is relevant image processing algorithm. A fast reconstruction algo-rithm is proposed for two dimensional 2×2 micro-scanning based on the sub-pixel imaging and reconstruction principle of two-dimensional stating focal plane arrays (FPA). Specifically, three initialization methods are presented and implemented with the simulated data, their performances are compared according to image quality index . Experiment results show that, by the first initialization approach, tirnely over-sampled image can be accurately recovered, although special field diaphragm is needed. In the second initialization, the extrapolation approximation in obtaining reconstruction results is better than either bilinear interpolation or over-sampling reconstruction, without requiting any special process on system. The proposed algorithm has simple structure, low computational cost and can be realized in real-time. A high-resolution image can be obtained by low-resolution detectors. So, the algorithm has potential applications in visible light and infrared imaging area.

  7. Two-dimensional calculus

    CERN Document Server

    Osserman, Robert

    2011-01-01

    The basic component of several-variable calculus, two-dimensional calculus is vital to mastery of the broader field. This extensive treatment of the subject offers the advantage of a thorough integration of linear algebra and materials, which aids readers in the development of geometric intuition. An introductory chapter presents background information on vectors in the plane, plane curves, and functions of two variables. Subsequent chapters address differentiation, transformations, and integration. Each chapter concludes with problem sets, and answers to selected exercises appear at the end o

  8. Two dimensional vernier

    Science.gov (United States)

    Juday, Richard D. (Inventor)

    1992-01-01

    A two-dimensional vernier scale is disclosed utilizing a cartesian grid on one plate member with a polar grid on an overlying transparent plate member. The polar grid has multiple concentric circles at a fractional spacing of the spacing of the cartesian grid lines. By locating the center of the polar grid on a location on the cartesian grid, interpolation can be made of both the X and Y fractional relationship to the cartesian grid by noting which circles coincide with a cartesian grid line for the X and Y direction.

  9. Saturated virtual fluorescence emission difference microscopy based on detector array

    Science.gov (United States)

    Liu, Shaocong; Sun, Shiyi; Kuang, Cuifang; Ge, Baoliang; Wang, Wensheng; Liu, Xu

    2017-07-01

    Virtual fluorescence emission difference microscopy (vFED) has been proposed recently to enhance the lateral resolution of confocal microscopy with a detector array, implemented by scanning a doughnut-shaped pattern. Theoretically, the resolution can be enhanced by around 1.3-fold compared with that in confocal microscopy. For further improvement of the resolving ability of vFED, a novel method is presented utilizing fluorescence saturation for super-resolution imaging, which we called saturated virtual fluorescence emission difference microscopy (svFED). With a point detector array, matched solid and hollow point spread functions (PSF) can be obtained by photon reassignment, and the difference results between them can be used to boost the transverse resolution. Results show that the diffraction barrier can be surpassed by at least 34% compared with that in vFED and the resolution is around 2-fold higher than that in confocal microscopy.

  10. The Telescope Array Middle Drum fluorescence detector simulation on GPUs

    Science.gov (United States)

    Abu-Zayyad, Tareq; Telescope-Array Collaboration

    2014-06-01

    In recent years, the Graphics Processing Unit (GPU) has been recognized and widely used as an accelerator for many scientific calculations. In general, problems amenable to parallelization are ones that benefit most from the use of GPUs. The Monte Carlo simulation of fluorescence detector response to air showers presents many opportunities for parallelization. In this paper we report on a Monte Carlo program used for the simulation of the Telescope Array Fluorescence Detector located at the Middle Drum site which uses GPU acceleration. All of the physics simulation from shower development, light production and atmospheric attenuation, as well as, the realistic detector optics and electronics simulations are done on the GPU. A detailed description of the code implementation is given, and results on the accuracy and performance of the simulation are presented as well. Improvements in computational throughput in excess of 50× are reported and the accuracy of the results is on par with the CPU implementation of the simulation.

  11. Imaging MAMA detector systems. [Multi-Anode Microchannel Array

    Science.gov (United States)

    Slater, David C.; Timothy, J. G.; Morgan, Jeffrey S.; Kasle, David B.

    1990-01-01

    Imaging multianode microchannel array (MAMA) detector systems with 1024 x 1024 pixel formats have been produced for visible and UV wavelengths; the UV types employ 'solar blind' photocathodes whose detective quantum efficiencies are significantly higher than those of currently available CCDs operating at far-UV and EUV wavelengths. Attention is presently given to the configurations and performance capabilities of state-of-the-art MAMA detectors, with a view to the development requirements of the hybrid electronic circuits needed for forthcoming spacecraft-sensor applications. Gain, dark noise, uniformity, and dynamic range performance data are presented for the curved-channel 'chevron', 'Z-plate', and helical-channel high gain microchannel plate configurations that are currently under evaluation with MAMA detector systems.

  12. READOUT SYSTEM FOR ARRAYS OF FRISCH-RING CDZNTE DETECTORS.

    Energy Technology Data Exchange (ETDEWEB)

    CUI, Y.; BOLOTNIKOV, A.E.; CAMARDA, G.S.; DE GERONIMO, G.; O' CONNOR, P.; JAMES, R.B.; KARGAR, A.; HARRISON, M.J.; MCGREGOR, D.S.

    2006-10-29

    Frisch-ring CdZnTe detectors have demonstrated good energy resolution for identifying isotopes, <1% FWHM at 662 keV, and good efficiency for detecting gamma rays. We will fabricate and test at Brookhaven National Laboratory an integrated module of a 64-element array of 6 x 6 x 12 mm{sup 3} Frisch-ring detectors, coupled with a readout electronics system. It supports 64 readout channels, and includes front-end electronics, signal processing circuit, USB interface and high-voltage power supply. The data-acquisition software is used to process the data stream, which includes amplitude and timing information for each detected event. This paper describes the design and assembly of the detector modules, readout electronics, and a conceptual prototype system. Some test results are also reported.

  13. The detector calibration system for the CUORE cryogenic bolometer array

    Science.gov (United States)

    Cushman, Jeremy S.; Dally, Adam; Davis, Christopher J.; Ejzak, Larissa; Lenz, Daniel; Lim, Kyungeun E.; Heeger, Karsten M.; Maruyama, Reina H.; Nucciotti, Angelo; Sangiorgio, Samuele; Wise, Thomas

    2017-02-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of 130Te and other rare events. The CUORE detector consists of 988 TeO2 bolometers operated underground at 10 mK in a dilution refrigerator at the Laboratori Nazionali del Gran Sasso. Candidate events are identified through a precise measurement of their energy. The absolute energy response of the detectors is established by the regular calibration of each individual bolometer using gamma sources. The close-packed configuration of the CUORE bolometer array combined with the extensive shielding surrounding the detectors requires the placement of calibration sources within the array itself. The CUORE Detector Calibration System is designed to insert radioactive sources into and remove them from the cryostat while respecting the stringent heat load, radiopurity, and operational requirements of the experiment. This paper describes the design, commissioning, and performance of this novel source calibration deployment system for ultra-low-temperature environments.

  14. Development and Production of Array Barrier Detectors at SCD

    Science.gov (United States)

    Klipstein, P. C.; Avnon, E.; Benny, Y.; Berkowicz, E.; Cohen, Y.; Dobromislin, R.; Fraenkel, R.; Gershon, G.; Glozman, A.; Hojman, E.; Ilan, E.; Karni, Y.; Klin, O.; Kodriano, Y.; Krasovitsky, L.; Langof, L.; Lukomsky, I.; Nevo, I.; Nitzani, M.; Pivnik, I.; Rappaport, N.; Rosenberg, O.; Shtrichman, I.; Shkedy, L.; Snapi, N.; Talmor, R.; Tessler, R.; Weiss, E.; Tuito, A.

    2017-09-01

    XB n or XB p barrier detectors exhibit diffusion-limited dark currents comparable with mercury cadmium telluride Rule-07 and high quantum efficiencies. In 2011, SemiConductor Devices (SCD) introduced "HOT Pelican D", a 640 × 512/15- μm pitch InAsSb/AlSbAs XB n mid-wave infrared (MWIR) detector with a 4.2- μm cut-off and an operating temperature of ˜150 K. Its low power (˜3 W), high pixel operability (>99.5%) and long mean time to failure make HOT Pelican D a highly reliable integrated detector-cooler product with a low size, weight and power. More recently, "HOT Hercules" was launched with a 1280 × 1024/15- μm format and similar advantages. A 3-megapixel, 10- μm pitch version ("HOT Blackbird") is currently completing development. For long-wave infrared applications, SCD's 640 × 512/15- μm pitch "Pelican-D LW" XB p type II superlattice (T2SL) detector has a ˜9.3- μm cut-off wavelength. The detector contains InAs/GaSb and InAs/AlSb T2SLs, and is fabricated into focal plane array (FPA) detectors using standard production processes including hybridization to a digital silicon read-out integrated circuit (ROIC), glue underfill and substrate thinning. The ROIC has been designed so that the complete detector closely follows the interfaces of SCD's MWIR Pelican-D detector family. The Pelican-D LW FPA has a quantum efficiency of ˜50%, and operates at 77 K with a pixel operability of >99% and noise equivalent temperature difference of 13 mK at 30 Hz and F/2.7.

  15. Muon-hadron detector of the carpet-2 array

    Science.gov (United States)

    Dzhappuev, D. D.; Kudzhaev, A. U.; Klimenko, N. F.

    2016-05-01

    The 1-GeV muon-hadron detector of the Carpet-2 multipurpose shower array at the Baksan Neutrino Observatory, Institute for Nuclear Research, Russian Academy of Sciences (INR, Moscow, Russia) is able to record simultaneously muons and hadrons. The procedure developed for this device makes it possible to separate the muon and hadron components to a high degree of precision. The spatial and energy features of the muon and hadron extensive-air-shower components are presented. Experimental data from the Carpet-2 array are contrasted against data from the EAS-TOP and KASCADE arrays and against the results of the calculations based on the CORSIKA (GHEISHA + QGSJET01) code package and performed for primary protons and iron nuclei.

  16. Mechanical design and development of TES bolometer detector arrays for the Advanced ACTPol experiment

    CERN Document Server

    Ward, Jonathan T; Beall, James A; Choi, Steve K; Crowley, Kevin T; Devlin, Mark J; Duff, Shannon M; Gallardo, Patricio M; Henderson, Shawn W; Ho, Shuay-Pwu Patty; Hilton, Gene; Hubmayr, Johannes; Khavari, Niloufar; Klein, Jeffrey; Koopman, Brian J; Li, Dale; McMahon, Jeffrey; Mumby, Grace; Nati, Federico; Niemack, Michael D; Page, Lyman A; Salatino, Maria; Schillaci, Alessandro; Schmitt, Benjamin L; Simon, Sara M; Staggs, Suzanne T; Thornton, Robert; Ullom, Joel N; Vavagiakis, Eve M; Wollack, Edward J

    2016-01-01

    The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling ~5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline profile leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at t...

  17. A new detector array for charged particle spectroscopy

    CERN Document Server

    Cowin, R L; Chappell, S P G; Clarke, N M; Freer, M; Fulton, B R; Cunningham, R A; Curtis, N; Dillon, G; Lilley, J; Jones, C D; Lee, P; Rae, W D M

    1999-01-01

    A compact and highly segmented detector array consisting of 44 gas-silicon-caesium iodide, position sensitive, particle identification detector telescopes and up to 10 position-sensitive, silicon strip detectors has been constructed for the study of light-ion-heavy-ion reactions including cluster break-up in the energy range 5-15 MeV/nucleon. The detectors are housed in a purpose built vacuum chamber. The telescopes are placed in fixed positions, covering the forward hemisphere from 3 to 30 deg. in the laboratory with the target placed at 535 mm from the front of the telescopes or 6-52 deg. with the target placed at 215 mm. The strip detectors are placed in any of 30 fixed positions in the forward hemisphere. For 85 MeV sup 1 sup 2 C ions the telescope energy resolution (gas plus silicon) is 345 keV with an angular resolution of 0.03 deg. . Using the gas-silicon section ions with Z up to 21 can be identified. For ions that pass through the silicon isotopic identification is achieved using the silicon-CsI comb...

  18. Prototype Imaging Cd-Zn-Te Array Detector

    CERN Document Server

    Bloser, P F; Grindlay, J E; Shah, K

    1998-01-01

    We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range $\\sim 10-600$ keV. The coded aperture imaging configuration requires only relatively large area pixels (1-3 mm), whereas the desired high energy response requires detector thicknesses of at least 3-5 mm. We have developed a prototype detector employing a 10 x 10 x 5 mm CZT substrate and 4 x 4 pixel (1.5 mm each) readout with gold metal contacts for the pixels and continuous gold contact for the bias on the opposite detector face. This MSM contact configuration was fabricated by RMD and tested at Harvard for uniformity, efficiency and spatial as well as spectral resolution. We have developed an ASIC readout (IDE-VA-1) and analysis system and report results, including $\\sim 4$% (FWHM) energy resolution at 60 keV. A protot...

  19. 二维稀疏相控阵声场优化及阵元故障影响分析%Optimization of Acoustic Field of Two-Dimensional Sparse Phased Array and the Effect Analysis of Element Errors

    Institute of Scientific and Technical Information of China (English)

    梅艳莹; 杨涛; 刘玉佼

    2014-01-01

    To address the issue of the grating lobes and side lobes of the acoustic field of two-dimensional sparse ultrasonic phased array,the formula for calculating the directivity of two-dimensional sparse ultrasonic phased array is deduced,and the transmit array and the receive array are interleavingly placed to eliminate grating lobes and sup-press side lobes.After optimization,the transverse and lateral scanning ranges have been expanded from 30°to 60°. Considering the effect of the damaged element on the directivity of acoustic field,the function of the acoustic field di-rectivity versus the position of the damaged element is established.the acoustic field simulation analysis shows that the element errors near the array center result in a maximum increase in side lobes of 20 dB,and the main lobe de-creases 6 dB independent of the location of the damaged element.When the damaged elements of the transmit array and the receive array are in the same place,the influence on array directivity reaches its maximum.%针对二维稀疏超声相控阵声场分布中的栅瓣和旁瓣问题,推导了二维稀疏超声相控阵的指向性公式,并利用发射阵列和接收阵列交错分布的方式消除栅瓣及抑制旁瓣,从而优化声场特性,优化后横向和侧向扫描范围由30°扩大到60°。建立了优化后阵列声场指向性与损坏阵元位置的函数关系式。声场指向性仿真结果表明,距阵列中心越近的阵元损坏时旁瓣升高越多,单个阵元损坏导致一级旁瓣最多升高20 dB,主瓣下降约6 dB,且与损坏阵元位置无关;相同位置的发射阵列和接收阵列阵元同时损坏时,对声场特性影响达到最大。

  20. Two-dimensional subwavelength plasmonic lattice solitons

    CERN Document Server

    Ye, F; Hu, B; Panoiu, N C

    2010-01-01

    We present a theoretical study of plasmonic lattice solitons (PLSs) formed in two-dimensional (2D) arrays of metallic nanowires embedded into a nonlinear medium with Kerr nonlinearity. We analyze two classes of 2D PLSs families, namely, fundamental and vortical PLSs in both focusing and defocusing media. Their existence, stability, and subwavelength spatial confinement are studied in detai

  1. Two-dimensional optical spectroscopy

    CERN Document Server

    Cho, Minhaeng

    2009-01-01

    Discusses the principles and applications of two-dimensional vibrational and optical spectroscopy techniques. This book provides an account of basic theory required for an understanding of two-dimensional vibrational and electronic spectroscopy.

  2. Feasibility study, software design, layout and simulation of a two-dimensional Fast Fourier Transform machine for use in optical array interferometry

    Science.gov (United States)

    Boriakoff, Valentin

    1994-01-01

    The goal of this project was the feasibility study of a particular architecture of a digital signal processing machine operating in real time which could do in a pipeline fashion the computation of the fast Fourier transform (FFT) of a time-domain sampled complex digital data stream. The particular architecture makes use of simple identical processors (called inner product processors) in a linear organization called a systolic array. Through computer simulation the new architecture to compute the FFT with systolic arrays was proved to be viable, and computed the FFT correctly and with the predicted particulars of operation. Integrated circuits to compute the operations expected of the vital node of the systolic architecture were proven feasible, and even with a 2 micron VLSI technology can execute the required operations in the required time. Actual construction of the integrated circuits was successful in one variant (fixed point) and unsuccessful in the other (floating point).

  3. Topological detector: measuring continuous dosimetric quantities with few-element detector array.

    Science.gov (United States)

    Han, Zhaohui; Brivio, Davide; Sajo, Erno; Zygmanski, Piotr

    2016-08-21

    A prototype topological detector was fabricated and investigated for quality assurance of radiation producing medical devices. Unlike a typical array or flat panel detector, a topological detector, while capable of achieving a very high spatial resolution, consists of only a few elements and therefore is much simpler in construction and more cost effective. The key feature allowing this advancement is a geometry-driven design that is customized for a specific dosimetric application. In the current work, a topological detector of two elements was examined for the positioning verification of the radiation collimating devices (jaws, MLCs, and blades etc). The detector was diagonally segmented from a rectangular thin film strip (2.5 cm  ×  15 cm), giving two contiguous but independent detector elements. The segmented area was the central portion of the strip measuring 5 cm in length. Under irradiation, signals from each detector element were separately digitized using a commercial multichannel data acquisition system. The center and size of an x-ray field, which were uniquely determined by the collimator positions, were shown mathematically to relate to the difference and sum of the two signals. As a proof of concept, experiments were carried out using slit x-ray fields ranging from 2 mm to 20 mm in size. It was demonstrated that, the collimator positions can be accurately measured with sub-millimeter precisions.

  4. Topological detector: measuring continuous dosimetric quantities with few-element detector array

    Science.gov (United States)

    Han, Zhaohui; Brivio, Davide; Sajo, Erno; Zygmanski, Piotr

    2016-08-01

    A prototype topological detector was fabricated and investigated for quality assurance of radiation producing medical devices. Unlike a typical array or flat panel detector, a topological detector, while capable of achieving a very high spatial resolution, consists of only a few elements and therefore is much simpler in construction and more cost effective. The key feature allowing this advancement is a geometry-driven design that is customized for a specific dosimetric application. In the current work, a topological detector of two elements was examined for the positioning verification of the radiation collimating devices (jaws, MLCs, and blades etc). The detector was diagonally segmented from a rectangular thin film strip (2.5 cm  ×  15 cm), giving two contiguous but independent detector elements. The segmented area was the central portion of the strip measuring 5 cm in length. Under irradiation, signals from each detector element were separately digitized using a commercial multichannel data acquisition system. The center and size of an x-ray field, which were uniquely determined by the collimator positions, were shown mathematically to relate to the difference and sum of the two signals. As a proof of concept, experiments were carried out using slit x-ray fields ranging from 2 mm to 20 mm in size. It was demonstrated that, the collimator positions can be accurately measured with sub-millimeter precisions.

  5. Fast, High-Precision Readout Circuit for Detector Arrays

    Science.gov (United States)

    Rider, David M.; Hancock, Bruce R.; Key, Richard W.; Cunningham, Thomas J.; Wrigley, Chris J.; Seshadri, Suresh; Sander, Stanley P.; Blavier, Jean-Francois L.

    2013-01-01

    The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

  6. Two-dimensional x-ray diffraction

    CERN Document Server

    He, Bob B

    2009-01-01

    Written by one of the pioneers of 2D X-Ray Diffraction, this useful guide covers the fundamentals, experimental methods and applications of two-dimensional x-ray diffraction, including geometry convention, x-ray source and optics, two-dimensional detectors, diffraction data interpretation, and configurations for various applications, such as phase identification, texture, stress, microstructure analysis, crystallinity, thin film analysis and combinatorial screening. Experimental examples in materials research, pharmaceuticals, and forensics are also given. This presents a key resource to resea

  7. Standard practice for radiological examination using digital detector arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice establishes the minimum requirements for radiological examination for metallic and nonmetallic material using a digital detector array (DDA) system. 1.2 The requirements in this practice are intended to control the quality of radiologic images and are not intended to establish acceptance criteria for parts or materials. 1.3 This practice covers the radiologic examination with DDAs including DDAs described in Practice E2597 such as a device that contains a photoconductor attached to a Thin Film Transistor (TFT) read out structure, a device that has a phosphor coupled directly to an amorphous silicon read-out structure, and devices where a phosphor is coupled to a CMOS (Complementary metal–oxide–semiconductor) array, a Linear Detector Array (LDA) or a CCD (charge coupled device) crystalline silicon read-out structure. 1.4 The DDA shall be selected for an NDT application based on knowledge of the technology described in Guide , and of the selected DDA properties provided by the manufactu...

  8. Discovery of hard-magnetic domains in two-dimensional arrays of soft-magnetic Fe{sub 3}O{sub 4} nanocubes

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Sun, Shuangshuang; Wang, Tiantian; Chen, Kezheng, E-mail: kchen@qust.edu.cn [Lab of Functional and Biomedical Nanomaterials, College of Materials Science and Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2015-08-21

    In this study, abnormal hard-magnetic domains were discovered in Fe{sub 3}O{sub 4}@C composite material, in which well-ordered 16-nm-sized Fe{sub 3}O{sub 4} cubes were tightly embedded into carbon sheets of tens of nanometers thick. It was found that ca. 40 columns of Fe{sub 3}O{sub 4} nanocubes magnetically self-assembled into a single strip-type domain with perpendicular magnetic anisotropy. More strikingly, remarkable domain misalignments, which were very similar to common edge dislocations among atomic planes in crystal lattices, were clearly observed and termed as “domain dislocation” in this work. The hard-magnetic properties of Fe{sub 3}O{sub 4}@C material, including large coercivity of 2150 Oe, high M{sub R}/M{sub S} value of 0.9, and strong anisotropy energy of 3.772 × 10{sup 5} erg/cm{sup 3}, were further ascertained by carefully designed electromagnetic absorption contrast experiments. It is anticipated that the discovery of hard-magnetic domains and domain dislocations within 2-D arrays of soft-magnetic nanomaterials will shed new light on the development of high-density perpendicular magnetic recording industry.

  9. TWO-DIMENSIONAL TOPOLOGY OF COSMOLOGICAL REIONIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yougang; Xu, Yidong; Chen, Xuelei [Key Laboratory of Computational Astrophysics, National Astronomical Observatories, Chinese Academy of Sciences, Beijing, 100012 China (China); Park, Changbom [School of Physics, Korea Institute for Advanced Study, 85 Hoegiro, Dongdaemun-gu, Seoul 130-722 (Korea, Republic of); Kim, Juhan, E-mail: wangyg@bao.ac.cn, E-mail: cbp@kias.re.kr [Center for Advanced Computation, Korea Institute for Advanced Study, 85 Hoegiro, Dongdaemun-gu, Seoul 130-722 (Korea, Republic of)

    2015-11-20

    We study the two-dimensional topology of the 21-cm differential brightness temperature for two hydrodynamic radiative transfer simulations and two semi-numerical models. In each model, we calculate the two-dimensional genus curve for the early, middle, and late epochs of reionization. It is found that the genus curve depends strongly on the ionized fraction of hydrogen in each model. The genus curves are significantly different for different reionization scenarios even when the ionized faction is the same. We find that the two-dimensional topology analysis method is a useful tool to constrain the reionization models. Our method can be applied to the future observations such as those of the Square Kilometre Array.

  10. Two dimensional topology of cosmological reionization

    CERN Document Server

    Wang, Yougang; Xu, Yidong; Chen, Xuelei; Kim, Juhan

    2015-01-01

    We study the two-dimensional topology of the 21-cm differential brightness temperature for two hydrodynamic radiative transfer simulations and two semi-numerical models. In each model, we calculate the two dimensional genus curve for the early, middle and late epochs of reionization. It is found that the genus curve depends strongly on the ionized fraction of hydrogen in each model. The genus curves are significantly different for different reionization scenarios even when the ionized faction is the same. We find that the two-dimensional topology analysis method is a useful tool to constrain the reionization models. Our method can be applied to the future observations such as those of the Square Kilometer Array.

  11. High-Speed, Low Power 256 Channel Gamma Radiation Array Detector ASIC Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Building on prior success in detector electronics, we propose to design and fabricate a 256 channel readout ASIC for solid state gamma radiation array detectors...

  12. MUST: A silicon strip detector array for radioactive beam experiments

    CERN Document Server

    Blumenfeld, Y; Sauvestre, J E; Maréchal, F; Ottini, S; Alamanos, N; Barbier, A; Beaumel, D; Bonnereau, B; Charlet, D; Clavelin, J F; Courtat, P; Delbourgo-Salvador, P; Douet, R; Engrand, M; Ethvignot, T; Gillibert, A; Khan, E; Lapoux, V; Lagoyannis, A; Lavergne, L; Lebon, S; Lelong, P; Lesage, A; Le Ven, V; Lhenry, I; Martin, J M; Musumarra, A; Pita, S; Petizon, L; Pollacco, E; Pouthas, J; Richard, A; Rougier, D; Santonocito, D; Scarpaci, J A; Sida, J L; Soulet, C; Stutzmann, J S; Suomijärvi, T; Szmigiel, M; Volkov, P; Voltolini, G

    1999-01-01

    A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm sup 2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and a...

  13. Advanced Antenna-Coupled Superconducting Detector Arrays for CMB Polarimetry

    Science.gov (United States)

    Bock, James

    2014-01-01

    We are developing high-sensitivity millimeter-wave detector arrays for measuring the polarization of the cosmic microwave background (CMB). This development is directed to advance the technology readiness of the Inflation Probe mission in NASA's Physics of the Cosmos program. The Inflation Probe is a fourth-generation CMB satellite that will measure the polarization of the CMB to astrophysical limits, characterizing the inflationary polarization signal, mapping large-scale structure based on polarization induced by gravitational lensing, and mapping Galactic magnetic fields through measurements of polarized dust emission. The inflationary polarization signal is produced by a background of gravitational waves from the epoch of inflation, an exponential expansion of space-time in the early universe, with an amplitude that depends on the physical mechanism producing inflation. The inflationary polarization signal may be distinguished by its unique 'B-mode' vector properties from polarization from the density variations that predominantly source CMB temperature anisotropy. Mission concepts for the Inflation Probe are being developed in the US, Europe and Japan. The arrays are based on planar antennas that provide integral beam collimation, polarization analysis, and spectral band definition in a compact lithographed format that eliminates discrete fore-optics such as lenses and feedhorns. The antennas are coupled to transition-edge superconducting bolometers, read out with multiplexed SQUID current amplifiers. The superconducting sensors and readouts developed in this program share common technologies with NASA X-ray and FIR detector applications. Our program targets developments required for space observations, and we discuss our technical progress over the past two years and plans for future development. We are incorporating arrays into active sub-orbital and ground-based experiments, which advance technology readiness while producing state of the art CMB

  14. In-line X-slot element focal plane array of kinetic inductance detectors

    NARCIS (Netherlands)

    Iacono, A.; Freni, A.; Neto, A.; Gerini, G.

    2011-01-01

    Kinetic Inductance Detectors are very promising THz imaging devices to be used in Focal Plane Array configuration. In this work a new antenna feed element has been studied and optimized. Preliminary results on array configuration are also shown.

  15. Antenna coupled detectors for 2D staring focal plane arrays

    Science.gov (United States)

    Gritz, Michael A.; Kolasa, Borys; Lail, Brian; Burkholder, Robert; Chen, Leonard

    2013-06-01

    Millimeter-wave (mmW)/sub-mmW/THz region of the electro-magnetic spectrum enables imaging thru clothing and other obscurants such as fog, clouds, smoke, sand, and dust. Therefore considerable interest exists in developing low cost millimeter-wave imaging (MMWI) systems. Previous MMWI systems have evolved from crude mechanically scanned, single element receiver systems into very complex multiple receiver camera systems. Initial systems required many expensive mmW integrated-circuit low-noise amplifiers. In order to reduce the cost and complexity of the existing systems, attempts have been made to develop new mmW imaging sensors employing direct detection arrays. In this paper, we report on Raytheon's recent development of a unique focal plane array technology, which operates broadly from the mmW through the sub-mmW/THz region. Raytheon's innovative nano-antenna based detector enables low cost production of 2D staring mmW focal plane arrays (mmW FPA), which not only have equivalent sensitivity and performance to existing MMWI systems, but require no mechanical scanning.

  16. Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

    Science.gov (United States)

    Ward, Jonathan T.; Austermann, Jason; Beall, James A.; Choi, Steve K.; Crowley, Kevin T.; Devlin, Mark J.; Duff, Shannon M.; Gallardo, Patricio M.; Henderson, Shawn W.; Ho, Shuay-Pwu Patty; Hilton, Gene; Hubmayr, Johannes; Khavari, Niloufar; Klein, Jeffrey; Koopman, Brian J.; Li, Dale; McMahon, Jeffrey; Mumby, Grace; Nati, Federico; Wollack, Edward J.

    2016-01-01

    The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

  17. GEM400: A front-end chip based on capacitor-switch array for pixel-based GEM detector

    Science.gov (United States)

    Li, H. S.; Jiang, X. S.; Liu, G.; Wang, N.; Sheng, H. Y.; Zhuang, B. A.; Zhao, J. W.

    2012-03-01

    The upgrade of Beijing Synchrotron Radiation Facility (BSRF) needs two-dimensional position-sensitive detection equipment to improve the experimental performance. Gas Electron Multiplier (GEM) detector, in particular, pixel-based GEM detector has good application prospects in the domain of synchrotron radiation. The read-out of larger scale pixel-based GEM detector is difficult for the high density of the pixels (PAD for collecting electrons). In order to reduce the number of cables, this paper presents a read-out scheme for pixel-based GEM detector, which is based on System-in-Package technology and ASIC technology. We proposed a circuit structure based on capacitor switch array circuit, and design a chip GEM400, which is a 400 channels ASIC. The proposed circuit can achieve good stability and low power dissipation. The chip is implemented in a 0.35μm CMOS process. The basic functional circuitry in ths chip includes analog switch, analog buffer, voltage amplifier, bandgap and control logic block, and the layout of this chip takes 5mm × 5mm area. The simulation results show that the chip can allow the maximum amount of input charge 70pC on the condition of 100pF external integrator capacitor. Besides, the chip has good channel uniformity (INL is better than 0.1%) and lower power dissipation.

  18. Matrix-addressed x-ray detector arrays

    Science.gov (United States)

    Street, Robert A.; Apte, Raj B.; Boyce, James B.; Ho, Jackson; Lau, Rachel; Lemmi, Francesco; Lu, Jeng-Ping; Mulato, Marcelo; Ready, Steve E.; Van Schuylenbergh, Koenraad

    2000-11-01

    Amorphous silicon (a-Si:H) technology has created a successful manufacturing business for large area active matrix arrays, of which liquid crystal displays (AMLCD) are the best known, and image sensors are an emerging technology for medical x-ray imaging. The large area, flat plate, format is the key feature of the technology that sets it apart from other digital imaging approaches. The principal requirements for medical imaging are sensitivity and high dynamic range. A-Si:H detectors have already proved to perform at least as well as x-ray film for radiographic applications and comparable to image intensifiers for fluoroscopy. There are several approaches to improving the performance of the image sensors is order to achieve higher sensitivity and higher spatial resolution. This paper describes some of these approaches.

  19. Two-dimensional photonic crystal surfactant detection.

    Science.gov (United States)

    Zhang, Jian-Tao; Smith, Natasha; Asher, Sanford A

    2012-08-07

    We developed a novel two-dimensional (2-D) crystalline colloidal array photonic crystal sensing material for the visual detection of amphiphilic molecules in water. A close-packed polystyrene 2-D array monolayer was embedded in a poly(N-isopropylacrylamide) (PNIPAAm)-based hydrogel film. These 2-D photonic crystals placed on a mirror show intense diffraction that enables them to be used for visual determination of analytes. Binding of surfactant molecules attaches ions to the sensor that swells the PNIPAAm-based hydrogel. The resulting increase in particle spacing red shifts the 2-D diffracted light. Incorporation of more hydrophobic monomers increases the sensitivity to surfactants.

  20. 64-pixel NbTiN superconducting nanowire single-photon detector array for spatially resolved photon detection

    CERN Document Server

    Miki, Shigehito; Wang, Zhen; Terai, Hirotaka

    2014-01-01

    We present the characterization of two-dimensionally arranged 64-pixel NbTiN superconducting nanowire single-photon detector array for spatially resolved photon detection. NbTiN films deposited on thermally oxidized Si substrates enabled the high-yield production of high-quality SSPD pixels, and all 64 SSPD pixels showed uniform superconducting characteristics. Furthermore, all of the pixels showed single-photon sensitivity, and 60 of the 64 pixels showed a pulse generation probability higher than 90% after photon absorption. As a result of light irradiation from the single-mode optical fiber at different distances between the fiber tip and the active area, the variations of system detection efficiency in each pixel showed reasonable Gaussian distribution to represent the spatial distributions of photon flux intensity.

  1. Gamma Ray Array Detector Trigger Sub-System

    CERN Document Server

    Zhong-Wei, Du; Yi, Qian; KongJie,

    2012-01-01

    Gamma Ray Array Detector (GRAD) is one of External Target Facility (ETF) subsystems at the Heavy Ion Research Facility at Lanzhou. The trigger subsystem of the GRAD has been developed based on Field Programmable Gate Array (FPGAs) and PXI interface. The GRAD trigger subsystem makes prompt L1 trigger decisions to select valid events. These decisions are made by processing the hit signals from 1024 CsI scintillators of the GRAD. According to the physical requirements, the GRAD trigger subsystem generates 12-bit trigger signals that are passed to the ETF global trigger system. In addition, the GRAD trigger subsystem generates trigger data that are packed and transmitted to the host computer via PXI bus for off-line analysis. The trigger processing is implemented in the front-end electronics and one FPGA of the trigger module. The logic of PXI transmission and reconfiguration is implemented in the other FPGA of the trigger module. The reliable and efficient performance in the Gamma-ray experiments demonstrates th...

  2. Use of two-dimensional chamber arrays in volumetric modulated arc therapy treatment verification; Empleo de matrices bidimensionales de camaras de ionizacion en la verificacion de tratamientos de arcoterapia volumetrica modulada

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, F.; Perez Vara, C.; Prieto Villacorta, M.; Fernandez Ruiz, M. L.; Ruiz Prados, M.

    2013-09-01

    Volumetric modulated arc therapy (VMAT) requires, as another kind of intensity-modulated radiation therapy (IMRT), patient-specific QA procedures. This work analyzes the method carried out in our institution for VMAT treatment verification. Our hypothesis is that traditional IMRT QA is valid for VMAT technique. Results obtained for absolute point-dose measurements with ion chamber are presented, as well as comparison with treatment planning system calculations (mean difference of (-0.50 {+-} 0.43)%). In addition, different setups with 2D ion chamber array for dose distributions comparison are analyzed. These detectors are the basis of our QA procedure. Advantages and disadvantages of those setups are shown. The present study includes results for 111 patients treated with VMAT technique from different disease sites. We conclude that 2D ion chamber arrays traditionally used in IMRT QA are valid detectors for rotational techniques if these arrays are used together with additional devices (phantoms, accessories) that allow us to obtain as much information as possible. (Author)

  3. Demonstration of a passive, low-noise, millimeter-wave detector array for imaging

    Science.gov (United States)

    Wikner, David; Grossman, Erich

    2009-05-01

    The design of a millimeter-wave (MMW) camera is presented. The camera is meant to serve as a demonstration platform for a new 32-channel MMW detector array that requires no pre-amplification prior to detection. The Army Research Laboratory (ARL) and National Institute of Standards and Technology (NIST) have worked with the Defense Advanced Research Projects Agency and several contractors for four years to develop an affordable MMW detector array technology suitable for use in a large staring array. The camera described uses one particular embodiment of detector array that resulted from the program. This paper reviews the design of the MMW optics that will be used to form imagery with the linear array and the tradeoffs made in that design. Also presented are the results of laboratory tests of the detector array that were made at both ARL and NIST.

  4. A two-dimensional Dirac fermion microscope

    Science.gov (United States)

    Bøggild, Peter; Caridad, José M.; Stampfer, Christoph; Calogero, Gaetano; Papior, Nick Rübner; Brandbyge, Mads

    2017-06-01

    The electron microscope has been a powerful, highly versatile workhorse in the fields of material and surface science, micro and nanotechnology, biology and geology, for nearly 80 years. The advent of two-dimensional materials opens new possibilities for realizing an analogy to electron microscopy in the solid state. Here we provide a perspective view on how a two-dimensional (2D) Dirac fermion-based microscope can be realistically implemented and operated, using graphene as a vacuum chamber for ballistic electrons. We use semiclassical simulations to propose concrete architectures and design rules of 2D electron guns, deflectors, tunable lenses and various detectors. The simulations show how simple objects can be imaged with well-controlled and collimated in-plane beams consisting of relativistic charge carriers. Finally, we discuss the potential of such microscopes for investigating edges, terminations and defects, as well as interfaces, including external nanoscale structures such as adsorbed molecules, nanoparticles or quantum dots.

  5. A two-dimensional Dirac fermion microscope.

    Science.gov (United States)

    Bøggild, Peter; Caridad, José M; Stampfer, Christoph; Calogero, Gaetano; Papior, Nick Rübner; Brandbyge, Mads

    2017-06-09

    The electron microscope has been a powerful, highly versatile workhorse in the fields of material and surface science, micro and nanotechnology, biology and geology, for nearly 80 years. The advent of two-dimensional materials opens new possibilities for realizing an analogy to electron microscopy in the solid state. Here we provide a perspective view on how a two-dimensional (2D) Dirac fermion-based microscope can be realistically implemented and operated, using graphene as a vacuum chamber for ballistic electrons. We use semiclassical simulations to propose concrete architectures and design rules of 2D electron guns, deflectors, tunable lenses and various detectors. The simulations show how simple objects can be imaged with well-controlled and collimated in-plane beams consisting of relativistic charge carriers. Finally, we discuss the potential of such microscopes for investigating edges, terminations and defects, as well as interfaces, including external nanoscale structures such as adsorbed molecules, nanoparticles or quantum dots.

  6. Fast Computation Methods Research for Two Dimensional MUSIC Spectrum Based on Circular Array%圆阵二维 MUSIC 谱快速计算方法研究

    Institute of Scientific and Technical Information of China (English)

    杜政东; 魏平; 赵菲; 尹文禄

    2015-01-01

    针对二维波达方向估计时 MUSIC 谱的快速计算问题,研究了均匀圆阵变换到虚拟线阵的 MUSIC 算法(UCA-ULA-MUSIC)、流形分离 MUSIC 算法(MS-MUSIC)、傅立叶域线性求根 MUSIC 算法(FD-Line-Search-MU-SIC)、基于 FFT 的2n 元均匀圆阵 MUSIC 算法(2n-UCA-FFT-MUSIC)与基于 FFT 的任意圆阵 MUSIC 算法(ACA-FFT-MUSIC)。对各种算法快速计算二维 MUSIC 谱的实现步骤进行了总结。在此基础上,给出了各算法计算二维MUSIC 谱的计算复杂度表达式,并以传统方法为参考,对比了各种快速算法相对于传统方法的计算复杂度比值;同时,针对不同的阵列形式,对适用的快速算法的测向性能进行了仿真对比。根据分析和对比的结果,指出 MS-MUSIC 算法与 ACA-FFT-MUSIC 算法具有更高的工程应用价值,由具体的情况单独或分频段联合使用 MS-MUSIC算法与 ACA-FFT-MUSIC 算法,可以使测向系统较好的兼顾测向性能与时效性。%According to the fast computation problem of MUSIC spectrum in two dimensional direction of arrival estimation, the fast algorithms by manifold transformation or spectrum function transformation are studied.The implementation steps of computation method for two dimensional MUSIC spectrum by these algorithms are summarized.Furthermore,expressions for computational complexity of discussed algorithms in computing two dimensional MUSIC spectrum are presented.With refer-ence to the conventional method,the ratio of computational complexity of discussed algorithms is compared.Meanwhile,for different circular arrays,the direction finding performance of applicable algorithms is compared by simulation.It is proved that the MUSIC algorithm based on Manifold Separation (MS-MUSIC)and Fast Fourier Transformation (FFT)which suits to arbitrary circular array (ACA-FFT-MUSIC)have higher engineering value according to the results of analysis and com-parison.The performance and

  7. ScintSim1: A new Monte Carlo simulation code for transport of optical photons in 2D arrays of scintillation detectors.

    Science.gov (United States)

    Mosleh-Shirazi, Mohammad Amin; Zarrini-Monfared, Zinat; Karbasi, Sareh; Zamani, Ali

    2014-01-01

    Two-dimensional (2D) arrays of thick segmented scintillators are of interest as X-ray detectors for both 2D and 3D image-guided radiotherapy (IGRT). Their detection process involves ionizing radiation energy deposition followed by production and transport of optical photons. Only a very limited number of optical Monte Carlo simulation models exist, which has limited the number of modeling studies that have considered both stages of the detection process. We present ScintSim1, an in-house optical Monte Carlo simulation code for 2D arrays of scintillation crystals, developed in the MATLAB programming environment. The code was rewritten and revised based on an existing program for single-element detectors, with the additional capability to model 2D arrays of elements with configurable dimensions, material, etc., The code generates and follows each optical photon history through the detector element (and, in case of cross-talk, the surrounding ones) until it reaches a configurable receptor, or is attenuated. The new model was verified by testing against relevant theoretically known behaviors or quantities and the results of a validated single-element model. For both sets of comparisons, the discrepancies in the calculated quantities were all detector optimization.

  8. Development of a fast pixel array detector for use in microsecond time-resolved x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barna, S.L.; Gruner, S.M.; Shepherd, J.A. [Princeton Univ., NJ (United States)] [and others

    1995-08-01

    A large-area pixel x-ray detector is being developed to collect eight successive frames of wide dynamic range two-dimensional images at 200kHz rates. Such a detector, in conjunction with a synchrotron radiation x-ray source, will enable time-resolved x-ray studies of proteins and other materials on time scales which have previously been inaccessible. The detector will consist of an array of fully-depleted 150 micron square diodes connected to a CMOS integrated electronics layer with solder bump-bonding. During each framing period, the current resulting from the x-rays stopped in the diodes is integrated in the electronics layer, and then stored in one of eight storage capacitors underneath the pixel. After the last frame, the capacitors are read out at standard data transmission rates. The detector has been designed for a well-depth of at least 10,000 x-rays (at 20keV), and a noise level of one x-ray. Ultimately, the authors intend to construct a detector with over one million pixels (1024 by 1024). They present the results of their development effort and various features of the design. The electronics design is discussed, with special attention to the performance requirements. The choice and design of the detective diodes, as they relate to x-ray stopping power and charge collection, are presented. An analysis of various methods of bump bonding is also presented. Finally, the authors discuss the possible need for a radiation-blocking layer, to be placed between the electronics and the detective layer, and various methods they have pursued in the construction of such a layer.

  9. Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs

    OpenAIRE

    Kempf, S.; Wegner, M; Gastaldo, L.; Fleischmann, A.; Enss, C.

    2013-01-01

    Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQU...

  10. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    of this thesis is on online comprehensive two-dimensional liquid chromatography (online LC×LC) with reverse phase in both dimensions (online RP×RP). Since online RP×RP has not been attempted before within this research group, a significant part of this thesis consists of knowledge and experience gained...

  11. Monte Carlo simulation of the standardization of {sup 22}Na using scintillation detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Y., E-mail: yss.sato@aist.go.j [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Murayama, H. [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage, Chiba 263-8555 (Japan); Yamada, T. [Japan Radioisotope Association, 2-28-45, Hon-komagome, Bunkyo, Tokyo 113-8941 (Japan); National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Tohoku University, 6-6, Aoba, Aramaki, Aoba, Sendai 980-8579 (Japan); Hasegawa, T. [Kitasato University, 1-15-1, Kitasato, Sagamihara, Kanagawa 228-8555 (Japan); Oda, K. [Tokyo Metropolitan Institute of Gerontology, 1-1 Nakacho, Itabashi-ku, Tokyo 173-0022 (Japan); Unno, Y.; Yunoki, A. [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Quantum Radiation Division, Radioactivity and Neutron Section, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2010-07-15

    In order to calibrate PET devices by a sealed point source, we contrived an absolute activity measurement method for the sealed point source using scintillation detector arrays. This new method was verified by EGS5 Monte Carlo simulation.

  12. Superconducting Thin-Film Interconnects for Cryogenic Photon Detector Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced imaging spectrometers for x-ray astronomy will require significant improvements in the high density interconnects between the detector arrays and the first...

  13. Method for producing a hybridization of detector array and integrated circuit for readout

    Science.gov (United States)

    Fossum, Eric R.; Grunthaner, Frank J.

    1993-08-01

    A process is explained for fabricating a detector array in a layer of semiconductor material on one substrate and an integrated readout circuit in a layer of semiconductor material on a separate substrate in order to select semiconductor material for optimum performance of each structure, such as GaAs for the detector array and Si for the integrated readout circuit. The detector array layer is lifted off its substrate, laminated on the metallized surface on the integrated surface, etched with reticulating channels to the surface of the integrated circuit, and provided with interconnections between the detector array pixels and the integrated readout circuit through the channels. The adhesive material for the lamination is selected to be chemically stable to provide electrical and thermal insulation and to provide stress release between the two structures fabricated in semiconductor materials that may have different coefficients of thermal expansion.

  14. Method of fabricating a PbS-PbSe IR detector array

    Science.gov (United States)

    Barrett, John R. (Inventor)

    1987-01-01

    A silicon wafer is provided which does not employ individually bonded leads between the IR sensitive elements and the input stages of multiplexers. The wafer is first coated with lead selenide in a first detector array area and is thereafter coated with lead sulfide within a second detector array area. The described steps result in the direct chemical deposition of lead selenide and lead sulfide upon the silicon wafer to eliminate individual wire bonding, bumping, flip chiping, planar interconnecting methods of connecting detector array elements to silicon chip circuitry, e.g., multiplexers, to enable easy fabrication of very long arrays. The electrode structure employed, produces an increase in the electrical field gradient between the electrodes for a given volume of detector material, relative to conventional electrode configurations.

  15. Characteristics of stereo images from detectors in focal plane array.

    Science.gov (United States)

    Son, Jung-Young; Yeom, Seokwon; Chun, Joo-Hwan; Guschin, Vladmir P; Lee, Dong-Su

    2011-07-01

    The equivalent ray geometry of two horizontally aligned detectors at the focal plane of the main antenna in a millimeter wave imaging system is analyzed to reveal the reason why the images from the detectors are fused as an image with a depth sense. Scanning the main antenna in both horizontal and vertical directions makes each detector perform as a camera, and the two detectors can work like a stereo camera in the millimeter wave range. However, the stereo camera geometry is different from that of the stereo camera used in the visual spectral range because the detectors' viewing directions are diverging to each other and they are a certain distance apart. The depth sense is mainly induced by the distance between detectors. The images obtained from the detectors in the millimeter imaging system are perceived with a good depth sense. The disparities responsible for the depth sense are identified in the images.

  16. On site calibration for new fluorescence detectors of the telescope array experiment

    Energy Technology Data Exchange (ETDEWEB)

    Tokuno, H. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan)], E-mail: htokuno@icrr.u-tokyo.ac.jp; Murano, Y. [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Kawana, S. [Graduate School of Science and Engineering, Saitama University, Saitama 338-8570 (Japan); Tameda, Y. [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Taketa, A.; Ikeda, D.; Udo, S. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Ogio, S. [Graduate School of Science, Osaka City University, Sumiyoshi, Osaka 558-8585 (Japan); Fukushima, M. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Azuma, R.; Fukuda, M. [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Inoue, N. [Graduate School of Science and Engineering, Saitama University, Saitama 338-8570 (Japan); Kadota, K. [Faculty of Knowledge Engineering, Musashi Institute of Technology, Setagaya, Tokyo 158-8557 (Japan); Kakimoto, F. [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Sagawa, H.; Sakurai, N.; Shibata, T.; Takeda, M. [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Tsunesada, Y. [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan)

    2009-04-01

    The Telescope Array experiment is searching for the origin of ultra-high energy cosmic rays using a ground array of particle detectors and three fluorescence telescope stations. The precise calibration of the fluorescence detectors is important for small systematic errors in shower reconstruction. This paper details the process of calibrating cameras for two of the fluorescence telescope stations. This paper provides the operational results of these camera calibrations.

  17. Enhancement of concentration range of chromatographically detectable components with array detector mass spectrometry

    Science.gov (United States)

    Enke, Christie

    2013-02-19

    Methods and instruments for high dynamic range analysis of sample components are described. A sample is subjected to time-dependent separation, ionized, and the ions dispersed with a constant integration time across an array of detectors according to the ions m/z values. Each of the detectors in the array has a dynamically adjustable gain or a logarithmic response function, producing an instrument capable of detecting a ratio of responses or 4 or more orders of magnitude.

  18. Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs

    CERN Document Server

    Kempf, S; Gastaldo, L; Fleischmann, A; Enss, C

    2013-01-01

    Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQUID multiplexer that operates in the frequency domain and that employs non-hysteretic rf-SQUIDs to transduce the detector signals into a frequency shift of high $Q$ resonators which can be monitored by using standard microwave measurement techniques. In this paper we discuss the design and the expected performance of a recently developed and fabricated 64 pixel detector array with integrated microwave SQUID multiplexer. First experimental data were obtained characterizing dc-SQUIDs with virtually identical washer design.

  19. Chemical imaging of cotton fibers using an infrared microscope and a focal-plane array detector

    Science.gov (United States)

    In this presentation, the chemical imaging of cotton fibers with an infrared microscope and a Focal-Plane Array (FPA) detector will be discussed. Infrared spectroscopy can provide us with information on the structure and quality of cotton fibers. In addition, FPA detectors allow for simultaneous spe...

  20. Trigger and aperture of the surface detector array of the Pierre Auger Observatory

    NARCIS (Netherlands)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Anticic, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Baecker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Barroso, S. L. C.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Belletoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Bluemer, H.; Bohacova, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceicao, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; Di Giulio, C.; Diaz, J. C.; Castro, M. L. Diaz; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; DuVernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipcic, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Froehlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; Garcia, B.; Garcia Gamez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gomez Berisso, M.; Goncalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gora, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hoerandel, J. R.; Horneffer, A.; Hrabovsky, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kegl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D. -H.; Krieger, A.; Kroemer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leao, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Lopez, R.; Lopez Aguera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martinez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Micanovic, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Ragaigne, D. Monnier; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafa, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nozka, L.; Nyklicek, M.; Oehlschlaeger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Selmi-Dei, D. Pakk; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; Pekala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Riviere, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodriguez-Frias, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouille-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sanchez, F.; Santander, M.; Santo, C. E.; Santo, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovanek, P.; Schroeder, F.; Schulte, S.; Schuessler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Smialkowski, A.; Smida, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijarvi, T.; Supanitsky, A. D.; Susa, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Tascau, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Peixoto, C. J. Todero; Tome, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdes Galicia, J. F.; Valino, I.; Valore, L.; van den Berg, A. M.; Vazquez, J. R.; Vazquez, R. A.; Veberic, D.; Venters, T.; Verzi, V.; Videla, M.; Villasenor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczynska, B.; Wilczynski, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single det

  1. Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors

    NARCIS (Netherlands)

    Yates, S. J. C.; Baryshev, A. M.; Baselmans, J. J. A.; Klein, B.; Guesten, R.

    2009-01-01

    Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing similar to 1000 s of devi

  2. Brief Introduction to the γ-DETECTOR Array at Institute of Modern Physics in Lanzhou

    Science.gov (United States)

    Hua, W.; Zhang, N. T.; Liu, M. L.; Zheng, Y.; Fang, Y. D.; Zhou, X. H.; Zhang, Y. H.; Lei, X. G.; Guo, Y. X.

    2013-11-01

    A new γ-detector array at Institute of modern physics in Lanzhou is now in construction. The spherical frame is designed using Solidworks, and is assembled by 4 kinds of irregular polygons. 32 detectors could be placed on this frame in maximum, which are arranged with 4-4-4-8-4-4-4 configuration.

  3. MCNP6 and DRiFT modeling efforts for the NEUANCE/DANCE detector array

    Energy Technology Data Exchange (ETDEWEB)

    Pinilla, Maria Isabel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-30

    This report seeks to study and benchmark code predictions against experimental data; determine parameters to match MCNP-simulated detector response functions to experimental stilbene measurements; add stilbene processing capabilities to DRiFT; and improve NEUANCE detector array modeling and analysis using new MCNP6 and DRiFT features.

  4. Trigger and aperture of the surface detector array of the Pierre Auger Observatory

    NARCIS (Netherlands)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Anticic, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Baecker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Barroso, S. L. C.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Belletoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Bluemer, H.; Bohacova, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceicao, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; Di Giulio, C.; Diaz, J. C.; Castro, M. L. Diaz; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; DuVernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipcic, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Froehlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; Garcia, B.; Garcia Gamez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gomez Berisso, M.; Goncalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gora, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hoerandel, J. R.; Horneffer, A.; Hrabovsky, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kegl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D. -H.; Krieger, A.; Kroemer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leao, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Lopez, R.; Lopez Aguera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martinez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Micanovic, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Ragaigne, D. Monnier; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafa, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nozka, L.; Nyklicek, M.; Oehlschlaeger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Selmi-Dei, D. Pakk; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; Pekala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Riviere, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodriguez-Frias, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouille-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sanchez, F.; Santander, M.; Santo, C. E.; Santo, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovanek, P.; Schroeder, F.; Schulte, S.; Schuessler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Smialkowski, A.; Smida, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijarvi, T.; Supanitsky, A. D.; Susa, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Tascau, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Peixoto, C. J. Todero; Tome, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdes Galicia, J. F.; Valino, I.; Valore, L.; van den Berg, A. M.; Vazquez, J. R.; Vazquez, R. A.; Veberic, D.; Venters, T.; Verzi, V.; Videla, M.; Villasenor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczynska, B.; Wilczynski, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single det

  5. Two dimensional unstable scar statistics.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Jorgenson, Roy Eberhardt; Kotulski, Joseph Daniel; Lee, Kelvin S. H. (ITT Industries/AES Los Angeles, CA)

    2006-12-01

    This report examines the localization of time harmonic high frequency modal fields in two dimensional cavities along periodic paths between opposing sides of the cavity. The cases where these orbits lead to unstable localized modes are known as scars. This paper examines the enhancements for these unstable orbits when the opposing mirrors are both convex and concave. In the latter case the construction includes the treatment of interior foci.

  6. Two-Dimensional Vernier Scale

    Science.gov (United States)

    Juday, Richard D.

    1992-01-01

    Modified vernier scale gives accurate two-dimensional coordinates from maps, drawings, or cathode-ray-tube displays. Movable circular overlay rests on fixed rectangular-grid overlay. Pitch of circles nine-tenths that of grid and, for greatest accuracy, radii of circles large compared with pitch of grid. Scale enables user to interpolate between finest divisions of regularly spaced rule simply by observing which mark on auxiliary vernier rule aligns with mark on primary rule.

  7. National Array of Neutron Detectors (NAND): A versatile tool for nuclear reaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Golda, K.S., E-mail: goldaks@gmail.com [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Jhingan, A.; Sugathan, P. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Singh, Hardev [Department of Physics, Kurukshetra University, Kurukshetra 136119 (India); Singh, R.P. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Behera, B.R. [Department of Physics, Panjab University, Chandigarh 160014 (India); Mandal, S. [Department of Physics and Astrophysics, Delhi University, New Delhi 110007 (India); Kothari, A.; Gupta, Arti; Zacharias, J.; Archunan, M.; Barua, P.; Venkataramanan, S.; Bhowmik, R.K. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Govil, I.M. [Department of Physics, Panjab University, Chandigarh 160014 (India); Datta, S.K.; Chatterjee, M.B. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India)

    2014-11-01

    The first phase of the National Array of Neutron Detectors (NAND) consisting of 26 neutron detectors has been commissioned at the Inter University Accelerator Centre (IUAC), New Delhi. The motivation behind setting up of such a detector system is the need for more accurate and efficient study of reaction mechanisms in the projectile energy range of 5–8 MeV/n using heavy ion beams from a 15 UD Pelletron and an upgraded LINAC booster facility at IUAC. The above detector array can be used for inclusive as well as exclusive measurements of reaction products of which at least one product is a neutron. While inclusive measurements can be made using only the neutron detectors along with the time of flight technique and a pulsed beam, exclusive measurements can be performed by detecting neutrons in coincidence with charged particles and/or fission fragments detected with ancillary detectors. The array can also be used for neutron tagged gamma-ray spectroscopy in (HI, xn) reactions by detecting gamma-rays in coincidence with the neutrons in a compact geometrical configuration. The various features and the performance of the different aspects of the array are described in the present paper. -- Highlights: •We report the design, fabrication and installation of a 26 element modular neutron detection system (NAND). •The array has been designed for the fusion–fission studies at near and above the barrier energies. •The relevant characteristics of the array are studied exhaustively and reported. •The efficiency of the detectors are measured and compared with the monte carlo simulations. •The second phase of the array will be augmented with 80 more neutron detectors which will enable the system to measure the neutron multiplicity distribution.

  8. Kinetic Inductance Detectors Based Receiver Array Architectures for Imaging at THz Frequency

    NARCIS (Netherlands)

    Iacono, A.; Neto, A.; Gerini, G.; Baselmans, J.; Yates, S.; Baryshev, A.; Hoevers, H.

    2009-01-01

    A novel strategy for broad band focal plane array design, resulting from the two years long cooperation between TNO and SRON (Space Research Organization Netherlands), is proposed. Its purpose is to couple the radiation from a Large F/D reflector system to an array of Kinetic Inductance detectors th

  9. A near-infrared 64-pixel superconducting nanowire single photon detector array with integrated multiplexed readout

    Energy Technology Data Exchange (ETDEWEB)

    Allman, M. S., E-mail: shane.allman@boulder.nist.gov; Verma, V. B.; Stevens, M.; Gerrits, T.; Horansky, R. D.; Lita, A. E.; Mirin, R.; Nam, S. W. [National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305-3328 (United States); Marsili, F.; Beyer, A.; Shaw, M. D. [Jet Propulsion Laboratory, 4800 Oak Grove Dr., Pasadena, California 91109 (United States); Kumor, D. [Purdue University, 610 Purdue Mall, West Lafayette, Indiana 47907 (United States)

    2015-05-11

    We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array as well as characterization measurements are discussed.

  10. A Near-Infrared 64-pixel Superconducting Nanowire Single Photon Detector Array with Integrated Multiplexed Readout

    CERN Document Server

    Allman, M S; Stevens, M; Gerrits, T; Horansky, R D; Lita, A E; Marsili, F; Beyer, A; Shaw, M D; Kumor, D; Mirin, R; Nam, S W

    2015-01-01

    We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array, as well as characterization measurements are discussed.

  11. 基于二维面探的高温合金GH4169残余应力分析%Residual Stress Analysis of High Temperature Alloy GH4169 by Two-dimensional Detector Method

    Institute of Scientific and Technical Information of China (English)

    叶璋; 王婧辰; 陈禹锡; 高玉魁

    2016-01-01

    目的 通过二维面探X射线衍射法测试高温合金GH4169的残余应力.方法 由于GH4169是Ni基高温合金,Ni合金在Cr靶下有较强衍射峰,因此采用Cr靶来测试GH4169合金的残余应力.二维面探仪有500个探测头,均匀分布在一个面上,根据每一个探测器测得的衍射角变化,就能得到500个方向上的应变值,再根据应力与应变之间的关系,就可以计算出材料的残余应力.结果 GH4169合金的德拜环只有一个衍射峰,而且衍射峰的强度随着角度α的变化而变化.这说明该材料的应力取向不均匀,存在较为明显的织构.该材料表面主应力方向上的残余应力测试值为-968 MPa,误差为62 MPa;切向上的残余应力测试值为24 MPa,误差为43 MPa.由于测试的GH4169合金是经过喷丸处理的,主应力方向上受残余压应力,而其测试结果 确为负值,说明此次测试结果 可信.结论 通过二维面探X射线衍射方法 测试材料残余应力从原理和实际操作上都是可行的,并成功测试出GH4169合金的残余应力.经喷丸处理后的GH4169材料受残余压应力的作用,且应力分布不均匀,存在较为明显的织构.%Objective To measure the residual stress of GH4169, a kind of high temperature alloy, using two-dimensional de-tector method. Methods Because GH4169 is a high temperature nickel base alloy which has a strong diffraction peak under the Cr target, this paper used Cr target to obtain the residual stress of GH4169 alloy. Using 500 detection heads uniformly distributed on a surface to measure diffraction angle changes, the portable X-ray machine could get the values of strain in 500 directions. Accord-ing to the relationship between stress and strain, the residual stress of the material could be calculated. Results The Debye ring of GH4169 alloy hasd only one diffraction peak and its intensity changed with the changes of angle alpha. This result showed that the stress orientation of the material

  12. A linear monolithic 4-6 on silicon IR detector array

    Science.gov (United States)

    Vandamme, J.; Vermeiren, J.; Zogg, H.; Masek, J.; Fabbricotti, M.

    1992-12-01

    A linear array of monolithically grown PbTe and PbSnSe detectors on (111)-Si for MWIR and TIR imaging applications was designed and processed. The array consists of a staggered row of 2 by 128 detectors on a 100 micrometers pitch. The readout circuitry, integrated on the Si substrate consists of a COS multiplexer with a direct injection input stage, a charge reduction stage and charge to voltage conversion stage for each individual detector. This XDI (MultipeXed Direct Injection) circuit also allows for on-chip nonuniformity compensation with a switched capacitor network.

  13. Study on data acquisition circuit used in SSPA linear array detector X-ray detection

    CERN Document Server

    Wei Biao; Che Zhen Ping

    2002-01-01

    After SSPA used as X-ray array detector is developed, the authors take a research on the data acquisition circuit applied to the detector. The experiment designed has verified the feasibility of application of this array detector and its data acquisition circuit to X-ray computed tomography (X-CT). The preliminary test results indicate that the method of the X-ray detection is feasible for industry X-CT nondestructive testing, which brings about advantage for detecting and measuring with high resolution, good efficiency and low cost

  14. Nuclear structure at high spin using multidetector gamma array and ancillary detectors

    Indian Academy of Sciences (India)

    S Muralithar

    2014-04-01

    A multidetector gamma array (GDA), for studying nuclear structure was built with ancillary devices namely gamma multiplicity filter and charged particle detector array. This facility was designed for in-beam gamma spectroscopy measurements in fusion evaporation reactions at Inter-University Accelerator Centre, New Delhi. Description of the facility and in-beam performance with two experimental studies done are presented. This array was used in a number of nuclear spectroscopic and reaction investigations.

  15. Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

    Science.gov (United States)

    Timothy, J. G.; Bybee, R. L.

    1983-01-01

    Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

  16. Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory

    CERN Document Server

    Abraham, J; Aglietta, M; Aguirre, C; Ahn, E J; Allard, D; Allekotte, I; Allen, J; Alvarez-Muñiz, J; Ambrosio, M; Anchordoqui, L; Andringa, S; Anzalone, A; Aramo, C; Arganda, E; Argirò, S; Arisaka, K; Arneodo, F; Arqueros, F; Asch, T; Asorey, H; Assis, P; Aublin, J; Ave, M; Avila, G; Bäcker, T; Badagnani, D; Barber, K B; Barbosa, A F; Barroso, S L C; Baughman, B; Bauleo, P; Beatty, J J; Beau, T; Becker, B R; Becker, K H; Bellétoile, A; Bellido, J A; BenZvi, S; Berat, C; Bernardini, P; Bertou, X; Biermann, P L; Billoir, P; Blanch-Bigas, O; Blanco, F; Bleve, C; Blümer, H; Boháčová, M; Boncioli, D; Bonifazi, C; Bonino, R; Borodai, N; Brack, J; Brogueira, P; Brown, W C; Bruijn, R; Buchholz, P; Bueno, A; Burton, R E; Busca, N G; Caballero-Mora, K S; Caramete, L; Caruso, R; Carvalho, W; Castellina, A; Catalano, O; Cazon, L; Cester, R; Chauvin, J; Chiavassa, A; Chinellato, J A; Chou, A; Chudoba, J; Chye, J; Clay, R W; Colombo, E; Conceição, R; Connolly, B; Contreras, F; Coppens, J; Cordier, A; Cotti, U; Coutu, S; Covault, C E; Creusot, A; Criss, A; Cronin, J; Curutiu, A; Dagoret-Campagne, S; Dallier, R; Daumiller, K; Dawson, B R; de Almeida, R M; De Domenico, M; De Donato, C; de Jong, S J; De La Vega, G; Junior, W J M de Mello; Neto, J R T de Mello; De Mitri, I; de Souza, V; de Vries, K D; Decerprit, G; del Peral, L; Deligny, O; Della Selva, A; Fratte, C Delle; Dembinski, H; Di Giulio, C; Diaz, J C; Diep, P N; Dobrigkeit, C; D'Olivo, J C; Dong, P N; Dorofeev, A; Anjos, J C dos; Dova, M T; D'Urso, D; Dutan, I; DuVernois, M A; Engel, R; Erdmann, M; Escobar, C O; Etchegoyen, A; Luis, P Facal San; Falcke, H; Farrar, G; Fauth, A C; Fazzini, N; Ferrer, F; Ferrero, A; Fick, B; Filevich, A; Filipčič, A; Fleck, I; Fliescher, S; Fracchiolla, C E; Fraenkel, E D; Fulgione, W; Gamarra, R F; Gambetta, S; García, B; Gámez, D García; Garcia-Pinto, D; Garrido, X; Gelmini, G; Gemmeke, H; Ghia, P L; Giaccari, U; Giller, M; Glass, H; Goggin, L M; Gold, M S; Golup, G; Albarracin, F Gomez; Berisso, M Gómez; Gonçalves, P; Amaral, M Gonçalves do; Gonzalez, D; Gonzalez, J G; Góra, D; Gorgi, A; Gouffon, P; Gozzini, S R; Grashorn, E; Grebe, S; Grigat, M; Grillo, A F; Guardincerri, Y; Guarino, F; Guedes, G P; Gutiérrez, J; Hague, J D; Halenka, V; Hansen, P; Harari, D; Harmsma, S; Harton, J L; Haungs, A; Healy, M D; Hebbeker, T; Hebrero, G; Heck, D; Hojvat, C; Holmes, V C; Homola, P; Hörandel, J R; Horneffer, A; Hrabovský, M; Huege, T; Hussain, M; Iarlori, M; Insolia, A; Ionita, F; Italiano, A; Jiraskova, S; Kaducak, M; Kampert, K H; Karova, T; Kasper, P; Kégl, B; Keilhauer, B; Kemp, E; Kieckhafer, R M; Klages, H O; Kleifges, M; Kleinfeller, J; Knapik, R; Knapp, J; Koang, D -H; Krieger, A; Krömer, O; Kruppke-Hansen, D; Kuehn, F; Kuempel, D; Kulbartz, K; Kunka, N; Kusenko, A; La Rosa, G; Lachaud, C; Lago, B L; Lautridou, P; Leão, M S A B; Lebrun, D; Lebrun, P; Lee, J; de Oliveira, M A Leigui; Lemiere, A; Letessier-Selvon, A; Leuthold, M; Lhenry-Yvon, I; López, R; Agüera, A Lopez; Louedec, K; Bahilo, J Lozano; Lucero, A; Lyberis, H; Maccarone, M C; Macolino, C; Maldera, S; Mandat, D; Mantsch, P; Mariazzi, A G; Maris, I C; Falcon, H R Marquez; Martello, D; Bravo, O Martínez; Mathes, H J; Matthews, J; Matthews, J A J; Matthiae, G; Maurizio, D; Mazur, P O; McEwen, M; McNeil, R R; Medina-Tanco, G; Melissas, M; Melo, D; Menichetti, E; Menshikov, A; Meyhandan, R; Micheletti, M I; Miele, G; Miller, W; Miramonti, L; Mollerach, S; Monasor, M; Ragaigne, D Monnier; Montanet, F; Morales, B; Morello, C; Moreno, J C; Morris, C; Mostafá, M; Moura, C A; Mueller, S; Muller, M A; Mussa, R; Navarra, G; Navarro, J L; Navas, S; Necesal, P; Nellen, L; Newman-Holmes, C; Newton, D; Nhung, P T; Nierstenhoefer, N; Nitz, D; Nosek, D; Nožka, L; Nyklicek, M; Oehlschläger, J; Olinto, A; Oliva, P; Olmos-Gilbaja, V M; Ortiz, M; Pacheco, N; Selmi-Dei, D Pakk; Palatka, M; Pallotta, J; Parente, G; Parizot, E; Parlati, S; Pastor, S; Patel, M; Paul, T; Pavlidou, V; Payet, K; Pech, M; Pȩkala, J; Pepe, I M; Perrone, L; Pesce, R; Petermann, E; Petrera, S; Petrinca, P; Petrolini, A; Petrov, Y; Petrovic, J; Pfendner, C; Piegaia, R; Pierog, T; Pimenta, M; Pinto, T; Pirronello, V; Pisanti, O; Platino, M; Pochon, J; Ponce, V H; Pontz, M; Privitera, P; Prouza, M; Quel, E J; Rautenberg, J; Ravel, O; Ravignani, D; Redondo, A; Revenu, B; Rezende, F A S; Ridky, J; Riggi, S; Risse, M; Rivière, C; Rizi, V; Robledo, C; Rodriguez, G; Martino, J Rodriguez; Rojo, J Rodriguez; Rodriguez-Cabo, I; Rodríguez-Frías, M D; Ros, G; Rosado, J; Rossler, T; Roth, M; Rouillé-d'Orfeuil, B; Roulet, E; Rovero, A C; Salamida, F; Salazar, H; Salina, G; Sánchez, F; Santander, M; Santo, C E; Santos, E M; Sarazin, F; Sarkar, S; Sato, R; Scharf, N; Scherini, V; Schieler, H; Schiffer, P; Schmidt, A; Schmidt, F; Schmidt, T; Scholten, O; Schoorlemmer, H; Schovancova, J; Schovánek, P; Schroeder, F; Schulte, S; Schüssler, F; Schuster, D; Sciutto, S J; Scuderi, M; Segreto, A; Semikoz, D; Settimo, M; Shellard, R C; Sidelnik, I; Siffert, B B; Sigl, G; Śmiałkowski, A; Šmída, R; Smith, B E; Snow, G R; Sommers, P; Sorokin, J; Spinka, H; Squartini, R; Strazzeri, E; Stutz, A; Suarez, F; Suomijärvi, T; Supanitsky, A D; Sutherland, M S; Swain, J; Szadkowski, Z; Tamashiro, A; Tamburro, A; Tarutina, T; Taşcău, O; Tcaciuc, R; Tcherniakhovski, D; Tegolo, D; Thao, N T; Thomas, D; Ticona, R; Tiffenberg, J; Timmermans, C; Tkaczyk, W; Peixoto, C J Todero; Tomé, B; Tonachini, A; Torres, I; Travnicek, P; Tridapalli, D B; Tristram, G; Trovato, E; Tueros, M; Ulrich, R; Unger, M; Urban, M; Galicia, J F Valdés; Valiño, I; Valore, L; Berg, A M van den; Vázquez, J R; Vázquez, R A; Veberič, D; Velarde, A; Venters, T; Verzi, V; Videla, M; Villaseñor, L; Vorobiov, S; Voyvodic, L; Wahlberg, H; Wahrlich, P; Wainberg, O; Warner, D; Watson, A A; Westerhoff, S; Whelan, B J; Wieczorek, G; Wiencke, L; Wilczyńska, B; Wilczyński, H; Wileman, C; Winnick, M G; Wu, H; Wundheiler, B; Yamamoto, T; Younk, P; Yuan, G; Yushkov, A; Zas, E; Zavrtanik, D; Zavrtanik, M; Zaw, I; Zepeda, A; Ziolkowski, M

    2011-01-01

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above $3\\times 10^{18}$ eV, for all zenith angles between 0$^\\circ$ and 60$^\\circ$, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

  17. Trigger and aperture of the surface detector array of the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, J. [National Technological University, Faculty Mendoza (CONICET/CNEA), Mendoza (Argentina); Abreu, P. [LIP and Instituto Superior Tecnico, Lisboa (Portugal); Aglietta, M. [Istituto di Fisica dello Spazio Interplanetario (INAF), Universita di Torino and Sezione INFN, Torino (Italy); Ahn, E.J. [Fermilab, Batavia, IL (United States); Allard, D. [Laboratoire AstroParticule et Cosmologie (APC), Universite Paris 7, CNRS-IN2P3, Paris (France); Allekotte, I. [Centro Atomico Bariloche and Instituto Balseiro (CNEA-UNCuyo-CONICET), San Carlos de Bariloche (Argentina); Allen, J. [New York University, New York, NY (United States); Alvarez-Muniz, J. [Universidad de Santiago de Compostela (Spain); Ambrosio, M. [Universita di Napoli ' Federico II' and Sezione INFN, Napoli (Italy); Anchordoqui, L. [University of Wisconsin, Milwaukee, WI (United States); Andringa, S. [LIP and Instituto Superior Tecnico, Lisboa (Portugal); Anticic, T. [Rudjer Boskovic Institute, 10000 Zagreb (Croatia); Anzalone, A. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo (INAF), Palermo (Italy); Aramo, C. [Universita di Napoli ' Federico II' and Sezione INFN, Napoli (Italy); Arganda, E. [Universidad Complutense de Madrid, Madrid (Spain); Arisaka, K. [University of California, Los Angeles, CA (United States); Arqueros, F. [Universidad Complutense de Madrid, Madrid (Spain); Asorey, H. [Centro Atomico Bariloche and Instituto Balseiro (CNEA-UNCuyo-CONICET), San Carlos de Bariloche (Argentina); Assis, P. [LIP and Instituto Superior Tecnico, Lisboa (Portugal); Aublin, J. [Laboratoire de Physique Nucleaire et de Hautes Energies (LPNHE), Universites Paris 6 et Paris 7, CNRS-IN2P3, Paris (France)

    2010-01-21

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3x10{sup 18}eV, for all zenith angles between 0 deg. and 60 deg., independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

  18. High-efficiency microstructured semiconductor neutron detectors that are arrayed, dual-integrated, and stacked

    Energy Technology Data Exchange (ETDEWEB)

    Bellinger, Steven L., E-mail: slb3888@ksu.edu [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Fronk, Ryan G. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Sobering, Timothy J. [Electronics Design Laboratory, Kansas State University, Manhattan, KS 66506 (United States); McGregor, Douglas S. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States)

    2012-07-15

    Silicon diodes with large aspect ratio 3D microstructures backfilled with {sup 6}LiF show a significant increase in neutron detection efficiency beyond that of conventional thin-film coated planar devices. Described in this work are advancements in the technology using detector stacking methods and summed-detector 6 Multiplication-Sign 6-element arraying methods to dramatically increase the sensitivity to thermal neutrons. The intrinsic detection efficiency of the 6 Multiplication-Sign 6 array for normal-incident 0.0253 eV neutrons was found 6.8% compared against a calibrated {sup 3}He proportional counter. - Highlights: Black-Right-Pointing-Pointer Solid-state semiconductor neutron detectors utilizing {sup 6}LiF. Black-Right-Pointing-Pointer Large aspect ratio 3D microstructured silicon diodes. Black-Right-Pointing-Pointer Arrayed solid-state semiconductor neutron detectors.

  19. The array of scintillation detectors with natural boron for EAS neutrons investigations

    Science.gov (United States)

    Gromushkin, D. M.; Bogdanov, F. A.; Khokhlov, S. S.; Kokoulin, R. P.; Kompaniets, K. G.; Petrukhin, A. A.; Shulzhenko, I. A.; Stenkin, Yu. V.; Yashin, I. I.; Yurin, K. O.

    2017-07-01

    The new URAN array has been constructed in the National Research Nuclear University MEPhI (Moscow, Russia). It is aimed at studying of primary cosmic rays in the "knee" region of energy spectrum and detects neutrons produced in interactions of EAS particles with nuclei of atmosphere or matter. The array consists of 72 detectors based on the scintillator with natural boron. Scintillator represents a silicon plate with the granules of ZnS(Ag) and B2O3 mixture. The area of the detector is 0.36 sq. m. Detectors are located on two roofs of the MEPhI laboratory buildings and are combined into clusters of 12 detectors. The structure and the main elements of the URAN array are described.

  20. Trigger and aperture of the surface detector array of the Pierre Auger Observatory

    Science.gov (United States)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muñiz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Antičić, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Bäcker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Barroso, S. L. C.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Bellétoile, A.; Bellido, J. A.; Benzvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; de Domenico, M.; de Donato, C.; de Jong, S. J.; de La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; de Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; Del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; di Giulio, C.; Diaz, J. C.; Díaz Castro, M. L.; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; Dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; Duvernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipčič, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Fröhlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; García, B.; García Gámez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gómez Berisso, M.; Gonçalves, P.; Gonzalez, D.; Gonzalez, J. G.; Góra, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hörandel, J. R.; Horneffer, A.; Hrabovský, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D.-H.; Krieger, A.; Krömer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martínez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Mičanović, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafá, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nožka, L.; Nyklicek, M.; Oehlschläger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; PeĶala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rivière, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouillé-D'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sánchez, F.; Santander, M.; Santo, C. E.; Santo, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovánek, P.; Schroeder, F.; Schulte, S.; Schüssler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Šuša, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Taşcău, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Todero Peixoto, C. J.; Tomé, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van den Berg, A. M.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Venters, T.; Verzi, V.; Videla, M.; Villaseñor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3×1018eV, for all zenith angles between 0∘ and 60∘, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

  1. Electronics for the Extensive Air Shower Detector Array at the University of Puebla

    Science.gov (United States)

    Pérez, E.; Conde, R.; Martínez, O.; Murrieta, T.; Salazar, H.; Villaseñor, L.

    2006-09-01

    In this paper we describe in detail the electronics cards that were designed to be the basis of the data acquisition system (DAS) of the extensive air shower detector array built in the Campus of the University of Puebla. The purpose of this observatory is to measure the energy and arrival direction of primary cosmic rays with energies around 1015 eV. The array consists of 18 liquid scintillator detectors (12 in the first stage) and 6 water Cherenkov detectors (one of 10 m2 cross section and five smaller ones of 1.86 m2 cross section), distributed in a square grid with a detector spacing of 20 m over an area of 4000 m2. The electronics described here uses analog to digital converters of 10 bits working at a sampling speed of 40 MS/s and field-programmable gate array (FPGA).

  2. Terahertz 3D printed diffractive lens matrices for field-effect transistor detector focal plane arrays.

    Science.gov (United States)

    Szkudlarek, Krzesimir; Sypek, Maciej; Cywiński, Grzegorz; Suszek, Jarosław; Zagrajek, Przemysław; Feduniewicz-Żmuda, Anna; Yahniuk, Ivan; Yatsunenko, Sergey; Nowakowska-Siwińska, Anna; Coquillat, Dominique; But, Dmytro B; Rachoń, Martyna; Węgrzyńska, Karolina; Skierbiszewski, Czesław; Knap, Wojciech

    2016-09-05

    We present the concept, the fabrication processes and the experimental results for materials and optics that can be used for terahertz field-effect transistor detector focal plane arrays. More specifically, we propose 3D printed arrays of a new type - diffractive multi-zone lenses of which the performance is superior to that of previously used mono-zone diffractive or refractive elements and evaluate them with GaN/AlGaN field-effect transistor terahertz detectors. Experiments performed in the 300-GHz atmospheric window show that the lens arrays offer both a good efficiency and good uniformity, and may improve the signal-to-noise ratio of the terahertz field-effect transistor detectors by more than one order of magnitude. In practice, we tested 3 × 12 lens linear arrays with printed circuit board THz detector arrays used in postal security scanners and observed significant signal-to-noise improvements. Our results clearly show that the proposed technology provides a way to produce cost-effective, reproducible, flat optics for large-size field-effect transistor THz-detector focal plane arrays.

  3. Results from the Antarctic Muon and Neutrino Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, J.; Bai, X.; Barwick, S.W.; Becka, T.; Becker, K.-H.; Bernaxdini, E.; Bertrand, D.; Binon, F.; Birone, A.; Boeser, S.; Botnerg, O.; Bouhali, O.; Burgess, T.; Carius, S.; Castermans, T.; Chen, A.; Chirkin, D.; Conrad, J.; Cooley, J.; Cowen, D.F.; Davour, A.; De Clercq, C.; DeYoung, T.; Desiati, P.; Dewulf, J.-P.; Doksus, P.; Ekstroem, P.; Feser, T.; Gaisser, T.K.; Gaug, M.; Gerhardt, L.; Goldschmidt, A.; Hallgren, A.; Halzen, F.; Hanson, K.; Hardtke, R.; Hauschildt, T.; Hellwig, M.; Herquet, P.; Hill, G.C.; Hulth, P.O.; Hundertmark, S.; Jacobsen, J.; Karle, A.; Koci, B.; Koepke, L.; Kuehn, K.; Kowalski, M.; Lamoureux, J.I.; Leich, H.; Leuthold, M.; Lindahl, P.; Liubarsky, I.; Madsen, J.; Marciniewski, P.; Matis, H.S.; McParland, C.P.; Minaeva, Y.; Miocinovic, P.; Morse, R.; Nahnhauer, R.; Neunhoeffer, T.; Niessen, P.; Nygren, D.R.; Ogelman, H.; Olbrechts, Ph.; Perez de los Heros, C.; Pohl, A.C.; Price, P.B.; Przybylski, G.T.; Rawlins, K.; Resconi, E.; Rhode, W.; Ribordy, M.; Richter, S.; Rodriguez Martino, J.; Ross, D.; Sander, H.-G.; Schmidt, T.; Schneider, D.; Schwarz, R.; Silvestri, A.; Solarz, M.; Spiczak, G.M.; Spiering, C.; Steele, D.; Steffen, P.; Stokstad, R.G.; Sudhoff, P.; Sulanke, K.-H.; Taboada, I.; Thollander, L.; Tilav, S.; Walck, C.; Weinheimer, C.; Wiebusch, C.H.; Wiedemann, C.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Yodh, G.; Young, S

    2003-04-01

    We show new results from both the older and newer incarnations of AMANDA (AMANDA-1310 and AMANDA-II, respectively). These results demonstrate that AMANDA is a functioning, multipurpose detector with significant physics and astrophysics reach. They include a new higher-statistics measurement of the atmospheric muon neutrino flux and preliminary results from searches for a variety of sources of ultrahigh energy neutrinos: generic point sources, gamma-ray bursters and diffuse sources producing muons in the detector, and diffuse sources producing electromagnetic or hadronic showers in or near the detector.

  4. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    Two-dimensional liquid chromatography has received increasing interest due to the rise in demand for analysis of complex chemical mixtures. Separation of complex mixtures is hard to achieve as a simple consequence of the sheer number of analytes, as these samples might contain hundreds or even...... dimensions. As a consequence of the conclusions made within this thesis, the research group has, for the time being, decided against further development of online LC×LC systems, since it was not deemed ideal for the intended application, the analysis of the polar fraction of oil. Trap-and...

  5. Automated response matching for organic scintillation detector arrays

    Science.gov (United States)

    Aspinall, M. D.; Joyce, M. J.; Cave, F. D.; Plenteda, R.; Tomanin, A.

    2017-07-01

    This paper identifies a digitizer technology with unique features that facilitates feedback control for the realization of a software-based technique for automatically calibrating detector responses. Three such auto-calibration techniques have been developed and are described along with an explanation of the main configuration settings and potential pitfalls. Automating this process increases repeatability, simplifies user operation, enables remote and periodic system calibration where consistency across detectors' responses are critical.

  6. Two-dimensional capillary origami

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, N.D., E-mail: nbrubaker@math.arizona.edu; Lega, J., E-mail: lega@math.arizona.edu

    2016-01-08

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  7. Non-volatile resistive photo-switches for flexible image detector arrays

    Science.gov (United States)

    Nau, Sebastian; Wolf, Christoph; Sax, Stefan; List-Kratochvil, Emil J. W.

    2015-09-01

    The increasing quest to find lightweight, conformable or flexible image detectors for machine vision or medical imaging brings organic electronics into the spotlight for these fields of application. Here were we introduce a unique imaging device concept and its utilization in an organic, flexible detector array with simple passive matrix wiring. We present a flexible organic image detector array built up from non-volatile resistive multi-bit photo-switchable elements. This unique realization is based on an organic photodiode combined with an organic resistive memory device wired in a simple crossbar configuration. The presented concept exhibits significant advantages compared to present organic and inorganic detector array technologies, facilitating the detection and simultaneous storage of the image information in one detector pixel, yet also allowing for simple read-out of the information from a simple passive-matrix crossbar wiring. This concept is demonstrated for single photo-switchable pixels as well as for arrays with sizes up to 32 by 32 pixels (1024 bit). The presented results pave the way for a versatile flexible and easy-to-fabricate sensor array technology. In a final step, the concept was expanded to detection of x-rays.

  8. Surface Micromachined Arrays of Transition-Edge Detectors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An innovative surface micromachining technique is described for the fabrication of closely-packed arrays of transition edge sensor (TES) x-ray microcalorimeters....

  9. Proton irradiation results for long-wave HgCdTe infrared detector arrays for NEOCam

    CERN Document Server

    Dorn, M; McMurtry, C; Hartman, S; Mainzer, A; McKelvey, M; McMurray, R; Chevara, D; Rosser, J

    2016-01-01

    HgCdTe detector arrays with a cutoff wavelength of ~10 ${\\mu}$m intended for the NEOCam space mission were subjected to proton beam irradiation at the University of California Davis Crocker Nuclear Laboratory. Three arrays were tested - one with 800 $\\mu$m substrate intact, one with 30 $\\mu$m substrate, and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe detector is grown, has been shown to produce luminescence in shorter wave HgCdTe arrays that causes elevated signal in non-hit pixels when subjected to proton irradiation. This testing was conducted to ascertain whether or not full substrate removal is necessary. At the dark level of the dewar, we detect no luminescence in non-hit pixels during proton testing for both the substrate-removed detector array and the array with 30 ${\\mu}$m substrate. The detector array with full 800 ${\\mu}$m substrate exhibited substantial photocurrent for a flux of 103 protons/cm$^2$-s at a beam energy of 18.1 MeV (~ 750 e$^-$/s) and 34.4 MeV ($\\sim$ 6...

  10. Torque magnetometry studies of two-dimensional electron systems

    NARCIS (Netherlands)

    Schaapman, Maaike Ruth

    2004-01-01

    This thesis describes a study of the magnetization two-dimensional electron gases (2DEGs). To detect the typically small magnetization, a sensitive magnetometer with optical angular detection was developed. The magnetometer uses a quadrant detector to measure the rotation of the sample. By mounting

  11. Torque magnetometry studies of two-dimensional electron systems

    NARCIS (Netherlands)

    Schaapman, Maaike Ruth

    2004-01-01

    This thesis describes a study of the magnetization two-dimensional electron gases (2DEGs). To detect the typically small magnetization, a sensitive magnetometer with optical angular detection was developed. The magnetometer uses a quadrant detector to measure the rotation of the sample. By mounting

  12. The DUV Stability of Superlattice-Doped CMOS Detector Arrays

    Science.gov (United States)

    Hoenk, M. E.; Carver, A. G.; Jones, T.; Dickie, M.; Cheng, P.; Greer, H. F.; Nikzad, S.; Sgro, J.; Tsur, S.

    2013-01-01

    JPL and Alacron have recently developed a high performance, DUV camera with a superlattice doped CMOS imaging detector. Supperlattice doped detectors achieve nearly 100% internal quantum efficiency in the deep and far ultraviolet, and a single layer, Al2O3 antireflection coating enables 64% external quantum efficiency at 263nm. In lifetime tests performed at Applied Materials using 263 nm pulsed, solid state and 193 nm pulsed excimer laser, the quantum efficiency and dark current of the JPL/Alacron camera remained stable to better than 1% precision during long-term exposure to several billion laser pulses, with no measurable degradation, no blooming and no image memory at 1000 fps.

  13. Two-dimensional quantum repeaters

    Science.gov (United States)

    Wallnöfer, J.; Zwerger, M.; Muschik, C.; Sangouard, N.; Dür, W.

    2016-11-01

    The endeavor to develop quantum networks gave rise to a rapidly developing field with far-reaching applications such as secure communication and the realization of distributed computing tasks. This ultimately calls for the creation of flexible multiuser structures that allow for quantum communication between arbitrary pairs of parties in the network and facilitate also multiuser applications. To address this challenge, we propose a two-dimensional quantum repeater architecture to establish long-distance entanglement shared between multiple communication partners in the presence of channel noise and imperfect local control operations. The scheme is based on the creation of self-similar multiqubit entanglement structures at growing scale, where variants of entanglement swapping and multiparty entanglement purification are combined to create high-fidelity entangled states. We show how such networks can be implemented using trapped ions in cavities.

  14. Two-dimensional capillary origami

    Science.gov (United States)

    Brubaker, N. D.; Lega, J.

    2016-01-01

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid.

  15. Two-dimensional cubic convolution.

    Science.gov (United States)

    Reichenbach, Stephen E; Geng, Frank

    2003-01-01

    The paper develops two-dimensional (2D), nonseparable, piecewise cubic convolution (PCC) for image interpolation. Traditionally, PCC has been implemented based on a one-dimensional (1D) derivation with a separable generalization to two dimensions. However, typical scenes and imaging systems are not separable, so the traditional approach is suboptimal. We develop a closed-form derivation for a two-parameter, 2D PCC kernel with support [-2,2] x [-2,2] that is constrained for continuity, smoothness, symmetry, and flat-field response. Our analyses, using several image models, including Markov random fields, demonstrate that the 2D PCC yields small improvements in interpolation fidelity over the traditional, separable approach. The constraints on the derivation can be relaxed to provide greater flexibility and performance.

  16. Mass Composition Sensitivity of an Array of Water Cherenkov and Scintillation Detectors

    CERN Document Server

    Gonzalez, Javier G; Roth, Markus

    2011-01-01

    We consider a hybrid array composed of scintillation and water Cherenkov detectors designed to measure the cosmic ray primary mass composition at energies of about 1 EeV. We have developed a simulation and reconstruction chain to study the theoretical performance of such an array. In this work we investigate the sensitivity of mass composition observables in relation to the geometry of the array. The detectors are arranged in a triangular grid with fixed 750 m spacing and the configuration of the scintillator detectors is optimized for mass composition sensitivity. We show that the performance for composition determination can be compared favorably to that of Xmax measurements after the difference in duty cycles is considered.

  17. IR Imaging Using Arrays of SiO2 Micromechanical Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Grbovic, Dragoslav [ORNL; Lavrik, Nickolay V [ORNL; Rajic, Slobodan [ORNL; Datskos, Panos G [ORNL; Hunter, Scott Robert [ORNL

    2012-01-01

    In this letter, we describe the fabrication of an array of bimaterial detectors for infrared (IR) imaging that utilize SiO2 as a structural material. All the substrate material underneath the active area of each detector element was removed. Each detector element incorporates an optical resonant cavity layer in the IR absorbing region of the sensing element. The simplified microfabrication process requires only four photolithographic steps with no wet etching or sacrificial layers. The thermomechanical deflection sensitivity was 7.9 10-3 rad/K which corresponds to a noise equivalent temperature difference (NETD) of 2.9 mK. In the present work the array was used to capture IR images while operating at room temperature and atmospheric pressure and no need for vacuum packaging. The average measured NETD of our IR detector system was approximately 200 mK but some sensing elements exhibited an NETD of 50 mK.

  18. Image quality evaluation of linear plastic scintillating fiber array detector for X-ray imaging

    Institute of Scientific and Technical Information of China (English)

    Mohammad Mehdi NASSERI; MA Qing-Li; YIN Ze-Jie

    2004-01-01

    It is important to assess image quality, in order to ensure that the imaging system is performing optimally and also identify the weak points in an imaging system. Three parameters mostly leading to image degradation are contrast, spatial resolution and noise. There is always a trade-off between spatial resolution and signal to noise ratio,but in scintillating fiber array detectors spatial resolution is not as important as signal to noise ratio, so we paid more attention to contrast and SNR of the system. By using GEANT4 Monte Carlo detector simulation toolkit, some effective parameters of the linear plastic scintillating fiber (PSF) array as an imaging detector were investigated. Finally we show that it is possible to use this kind of detector to take CT and DR (Digital Radiography) image under certain conditions.

  19. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Flores, J.L. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain); Martel, I. [Dpto de Física Aplicada, Universidad de Huelva (Spain); CERN, ISOLDE, CH 1211 Geneva, 23 (Switzerland); Jiménez, R. [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Galán, J., E-mail: jgalan@diesia.uhu.es [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Salmerón, P. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain)

    2016-09-11

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from {sup 12}C up to {sup 84}Kr, yielding higher discrimination rates than any other previously reported.

  20. Analysis of upper and lower bounds of the frame noise in linear detector arrays

    Science.gov (United States)

    Jaggi, S.

    1991-01-01

    This paper estimates the upper and lower bounds of the frame noise of a linear detector array that uses a one-dimensional scan pattern. Using chi-square distribution, it is analytically shown why it is necessary to use the average of the variances and not the average of the standard deviations to estimate these bounds. Also, a criteria for determining whether any excessively noisy lines exist among the detectors is derived from these bounds. Using a Gaussian standard random variable generator, these bounds are demonstrated to be accurate within the specified confidence interval. A silicon detector array is then used for actual dark current measurements. The criterion developed for determination of noisy detectors is checked on the experimentally obtained data.

  1. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Science.gov (United States)

    Flores, J. L.; Martel, I.; Jiménez, R.; Galán, J.; Salmerón, P.

    2016-09-01

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from 12C up to 84Kr, yielding higher discrimination rates than any other previously reported.

  2. 二维氧化锌纳米阵列的制备及光学吸收特性研究%Research on the Preparation and Optical Absorption Properties of Two-Dimensional ZnO Array

    Institute of Scientific and Technical Information of China (English)

    乔璐; 朱亚彬; 徐浩

    2014-01-01

    采用漂移法,在玻璃衬底上制备出粒径分别为117,350和500 nm单层、大面积的聚苯乙烯胶体球掩膜板,在已制得的掩膜板上用射频磁控溅射的方法沉积一层氧化锌薄膜,最后用有机溶液四氢呋喃(THF)浸泡去除聚苯乙烯胶体球,获得不同粒径的二维氧化锌纳米团簇。通过扫描电子显微镜和能量色散X射线光谱仪对样品的形貌及成份进行表征,表明所制得样品为有序分布的蜂窝网状氧化锌纳米阵列。在室温下,通过吸收光谱仪测试样品在300~800 nm波长范围内的吸收光谱,结果表明对于具有不同尺寸晶粒的氧化锌纳米团簇样品,随着所采用的聚苯乙烯胶体球粒径的增大,即氧化锌纳米团簇粒径的增加,光吸收峰出现了宽化和红移;随着溅射时间的延长,即氧化锌薄膜膜厚的增加,光吸收率提高。此外,对氧化锌纳米团簇阵列的光吸收特性进行了基于离散偶极子近似的理论计算从而获得任意形状和尺寸粒子的吸收。目前,文献报道中用此理论计算各种形状的纳米金、银等金属的结果与实验结果相符,但是应用离散偶极子的近似理论计算氧化锌纳米颗粒的报道很少。应用此理论计算三角棱台形状的氧化锌光学吸收特性,根据氧化锌薄膜介电常数和膜厚的变化进行光吸收特性的模拟,并解释了实验结果。%The present paper’s main work is firstly preparing a single layer and a large area polystyrene microspheres mask,with 117,350 and 500 nm in diameter,and then depositing a layer of zinc oxide thin film on the mask board by RF magnetron sputte-ring technique,using nanospheres lithography technique to remove the polystyrene spheres by soaking with tetrahydrofuran,and two-dimensional zinc oxide nano-array samples were obtained at last.The samples were characterized on the morphology and composition by scanning electron microscopy

  3. Calibration and quality control of a multi leaf collimator using linear array of detectors; Calibracion y control de calidad de un colimador multilaminas mediante array lineal de detectores

    Energy Technology Data Exchange (ETDEWEB)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-07-01

    The protocol for calibration and quality control established by Siemens for the multi leaf collimator (MLC) of Primus electron linear accelerators, using the light field coincidence with the beam of radiation to determine the position of the blades. In this paper, we illustrate the use of a calibration method for determining the positions of MLC plates radiologically with the help of a linear array of detectors, based on the proposal Lopes et al (2007).

  4. Measurements of High Energy X-Ray Dose Distributions Using Multi-Dimensional Fiber-Optic Radiation Detectors

    Science.gov (United States)

    Jang, Kyoung Won; Cho, Dong Hyun; Shin, Sang Hun; Lee, Bongsoo; Chung, Soon-Cheol; Tack, Gye-Rae; Yi, Jeong Han; Kim, Sin; Cho, Hyosung

    In this study, we have fabricated multi-dimensional fiber-optic radiation detectors with organic scintillators, plastic optical fibers and photo-detectors such as photodiode array and a charge-coupled device. To measure the X-ray dose distributions of the clinical linear accelerator in the tissue-equivalent medium, we have fabricated polymethylmethacrylate phantoms which have one-dimensional and two-dimensional fiber-optic detector arrays inside. The one-dimensional and two-dimensional detector arrays can be used to measure percent depth doses and surface dose distributions of high energy X-ray in the phantom respectively.

  5. Measuring 235U(n,xnγ) Cross Sections with HPGe Detector Array

    Institute of Scientific and Technical Information of China (English)

    WANG; Zhao-hui; WANG; Qi; SU; Xiao-bin; LI; Xia; HOU; Long; ZHANG; Kai; CHEN; Hong-tao; ZHAO; Fang

    2015-01-01

    We had built the array of HPGe detectors,which is used to measure theγrays from(n,xn)reaction.The detection system,acquisition system and analysis method have been improved to meet the requirement of prompt gamma ray measurement.According to the research of angular distribution of secondary gamma ray,we adjust the location and angle of detectors(Fig.1).Due to the absence of suitable sample,

  6. Energy spectrum of UHECRs measured by newly constructed fluorescence detectors in Telescope Array experiment

    Directory of Open Access Journals (Sweden)

    Fujii Toshihiro

    2013-06-01

    Full Text Available Telescope Array (TA experiment is the largest hybrid detector to observe ultra-high energy cosmic rays (UHECRs in the northern hemisphere. In the TA experiment, we newly designed and constructed 24 fluorescence detectors (FDs located at two stations. We report the energy spectrum of UHECRs with energies above 1017.5 eV from analyzing data collected by the new FDs during the first 3.7 years in monocular mode.

  7. The water Cherenkov detector array for studies of cosmic rays at the University of Puebla

    Science.gov (United States)

    Cotzomi, J.; Moreno, E.; Murrieta, T.; Palma, B.; Pérez, E.; Salazar, H.; Villaseñor, L.

    2005-11-01

    We describe the design and performance of a hybrid extensive air shower detector array built on the Campus of the University of Puebla ( 19∘N, 90∘W, 800 g/cm2) to measure the energy, arrival direction and composition of primary cosmic rays with energies around 1 PeV, i.e., around the knee of the cosmic ray spectrum. The array consists of 3 water Cherenkov detectors of 1.86 m2 cross-section and 12 liquid scintillator detectors of 1 m2 distributed in a square grid with a detector spacing of 20 m over an area of 4000 m2. We discuss the calibration and stability of the array for both sets of detectors and report on preliminary measurements and reconstruction of the lateral distributions for the electromagnetic (EM) and muonic components of extensive air showers. We also discuss how the hybrid character of the array can be used to measure mass composition of the primary cosmic rays by estimating the relative contents of muons with respect to the EM component of extensive air showers. This facility is also used to train students interested in the field of cosmic rays.

  8. Hybrid Extensive Air Shower Detector Array at the University of Puebla to Study Cosmic Rays

    Science.gov (United States)

    Martínez, O.; Pérez, E.; Salazar, H.; Villaseñor, L.

    We describe the design of an extensive air shower detector array built in the Campus of the University of Puebla (located at 19°N, 90°W, 800 gcm -2) to measure the energy and arrival direction of primary cosmic rays with energies around 1015 eV. The array consists of 18 liquid scintillator detectors (12 in the first stage) and 6 water Cherenkov detectors (one of 10 m 2 cross section and five smaller ones of 1.86 m 2 cross section), distributed in a square grid with a detector spacing of 20 m over an area of 4000 m 2. In this paper we discuss the calibration and stability of the array, and discuss the capability of hybrid arrays, such as this one consisting of water Cherenkov and liquid scintillator detectors, to allow a separation of the electromagnetic and muon components of extensive air showers. This separation plays an important role in the determination of the mass and identity of the primary cosmic ray. This facility is also used to train students interested in the field of cosmic rays.

  9. A sub-millimeter resolution PET detector module using a multi-pixel photon counter array.

    Science.gov (United States)

    Song, Tae Yong; Wu, Heyu; Komarov, Sergey; Siegel, Stefan B; Tai, Yuan-Chuan

    2010-05-07

    A PET block detector module using an array of sub-millimeter lutetium oxyorthosilicate (LSO) crystals read out by an array of surface-mount, semiconductor photosensors has been developed. The detector consists of a LSO array, a custom acrylic light guide, a 3 x 3 multi-pixel photon counter (MPPC) array (S10362-11-050P, Hamamatsu Photonics, Japan) and a readout board with a charge division resistor network. The LSO array consists of 100 crystals, each measuring 0.8 x 0.8 x 3 mm(3) and arranged in 0.86 mm pitches. A Monte Carlo simulation was used to aid the design and fabrication of a custom light guide to control distribution of scintillation light over the surface of the MPPC array. The output signals of the nine MPPC are multiplexed by a charge division resistor network to generate four position-encoded analog outputs. Flood image, energy resolution and timing resolution measurements were performed using standard NIM electronics. The linearity of the detector response was investigated using gamma-ray sources of different energies. The 10 x 10 array of 0.8 mm LSO crystals was clearly resolved in the flood image. The average energy resolution and standard deviation were 20.0% full-width at half-maximum (FWHM) and +/-5.0%, respectively, at 511 keV. The timing resolution of a single MPPC coupled to a LSO crystal was found to be 857 ps FWHM, and the value for the central region of detector module was 1182 ps FWHM when +/-10% energy window was applied. The nonlinear response of a single MPPC when used to read out a single LSO was observed among the corner crystals of the proposed detector module. However, the central region of the detector module exhibits significantly less nonlinearity (6.5% for 511 keV). These results demonstrate that (1) a charge-sharing resistor network can effectively multiplex MPPC signals and reduce the number of output signals without significantly degrading the performance of a PET detector and (2) a custom light guide to permit light sharing

  10. Extensive Air Shower Detector Array at the Universidad Autonoma de Puebla

    Science.gov (United States)

    Cotzomi, J.; Moreno, E.; Aguilar, S.; Palma, B.; Martinez, O.; Salazar, H.; Villasenor, L.

    2002-07-01

    We describe the operation of an Extensive Air Shower Array located at the campus of the FCFM-BUAP. The array consists of 8 liquid scintillation detectors with a surface of 1 m2 each and a detector spacing of 20 m in a square grid. The array was designed to measure the energy and arrival direction of primary particles that generate extensive air showers (EAS) in the region of 1013 eV - 1016 eV. The angular distribution measured with this array, Cos8(Theta) xSin(Theta), agrees very well with the literature. We also present the measured energies of a number of vertical showers in the range of 5 x1012 eV to 5 x1013 eV.

  11. Implementation of digital multiplexing for high resolution X-ray detector arrays.

    Science.gov (United States)

    Sharma, P; Swetadri Vasan, S N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S

    2012-01-01

    We describe and demonstrate for the first time the use of the novel Multiple Module Multiplexer (MMMIC) for a 2×2 array of new electron multiplying charge coupled device (EMCCD) based x-ray detectors. It is highly desirable for x-ray imaging systems to have larger fields of view (FOV) extensible in two directions yet to still be capable of doing high resolution imaging over regions-of-interest (ROI). The MMMIC achieves these goals by acquiring and multiplexing data from an array of imaging modules thereby enabling a larger FOV, and at the same time allowing high resolution ROI imaging through selection of a subset of modules in the array. MMMIC also supports different binning modes. This paper describes how a specific two stage configuration connecting three identical MMMICs is used to acquire and multiplex data from a 2×2 array of EMCCD based detectors. The first stage contains two MMMICs wherein each MMMIC is getting data from two EMCCD detectors. The multiplexed data from these MMMICs is then forwarded to the second stage MMMIC in the similar fashion. The second stage that has only one MMMIC gives the final 12 bit multiplexed data from four modules. This data is then sent over a high speed Camera Link interface to the image processing computer. X-ray images taken through the 2×2 array of EMCCD based detectors using this two stage configuration of MMMICs are shown successfully demonstrating the concept.

  12. Magnetic order in two-dimensional nanoparticle assemblies

    NARCIS (Netherlands)

    Georgescu, M

    2008-01-01

    This thesis involves a fundamental study of two-dimensional arrays of magnetic nanoparticles using non-contact Atomic Force Microscopy, Magnetic Force Microscopy, and Atomic Force Spectroscopy. The goal is to acquire a better understanding of the interactions between magnetic nanoparticles and the

  13. Magnetic order in two-dimensional nanoparticle assemblies

    NARCIS (Netherlands)

    Georgescu, M

    2008-01-01

    This thesis involves a fundamental study of two-dimensional arrays of magnetic nanoparticles using non-contact Atomic Force Microscopy, Magnetic Force Microscopy, and Atomic Force Spectroscopy. The goal is to acquire a better understanding of the interactions between magnetic nanoparticles and the r

  14. Measurement of the Proton-Air Cross Section with Telescope Array's Middle Drum Detector and Surface Array in Hybrid Mode

    CERN Document Server

    Abbasi, R U; Abu-Zayyad, T; Allen, M; Anderson, R; Azuma, R; Barcikowski, E; Belz, J W; Bergman, D R; Blake, S A; Cady, R; Chae, M J; Cheon, B G; Chiba, J; Chikawa, M; Cho, W R; Fujii, T; Fukushima, M; Goto, T; Hanlon, W; Hayashi, Y; Hayashida, N; Hibino, K; Honda1, K; Ikeda, D; Inoue, N; Ishii, T; Ishimori, R; Ito, H; Ivanov, D; Jui, C C H; Kadota, K; Kakimoto, F; Kalashev, O; Kasahara, K; Kawai, H; Kawakami, S; Kawana, S; Kawata, K; Kido, E; Kim, H B; Kim, J H; Kitamura, S; Kitamura, Y; Kuzmin, V; Kwon, Y J; Lan1, J; Lim, S I; Lundquist, J P; Machida, K; Martens, K; Matsuda, T; Matsuyama, T; Matthews, J N; Minamino, M; Mukai, K; Myers, I; Nagasawa, K; Nagataki1, S; Nakamura, T; Nonaka, T; Nozato, A; Ogio, S; Ogura, J; Ohnishi, M; Ohoka, H; Oki, K; Okuda, T; Ono, M; Oshima, A; Ozawa, S; Park, I H; Pshirkov, M S; Rodriguez, D C; Rubtsov, G; Ryu, D; Sagawa, H; Sakurai, N; Sampson, A L; Scott, L M; Shah, P D; Shibata, F; Shibata, T; Shimodaira, H; Shin, B K; Smith, J D; Sokolsky, P; Springer, R W; Stokes, B T; Stratton, S R; Stroman, T A; Suzawa, T; Takamura, M; Takeda, M; Takeishi, R; Taketa, A; Takita, M; Tameda, Y; Tanaka, H; Tanaka, K; Tanaka, M; Thomas, S B; Thomson, G B; Tinyakov, P; Tkachev, I; Tokuno, H; Tomida, T; Troitsky, S; Tsunesada, Y; Tsutsumi, K; Uchihori, Y; Udo, S; Urban, F; Vasiloff, G; Wong, T; Yamane, R; Yamaoka, H; Yamazaki, K; Yang, J; Yashiro, K; Yoneda, Y; Yoshida, S; Yoshii, H; Zollinger, R; Zundel, Z

    2015-01-01

    In this work we are reporting on the measurement of the proton-air inelastic cross section $\\sigma^{\\rm inel}_{\\rm p-air}$ using the Telescope Array (TA) detector. Based on the measurement of the $\\sigma^{\\rm inel}_{\\rm p-air}$ the proton-proton cross section $\\sigma_{\\rm p-p}$ value is also determined at $\\sqrt{s} = 95$ TeV. Detecting cosmic ray events at ultra high energies with Telescope Array enables us to study this fundamental parameter that we are otherwise unable to access with particle accelerators. The data used in this report is collected over five years using hybrid events observed by the Middle Drum fluorescence detector together with the surface array detector. The value of the $\\sigma^{\\rm inel}_{\\rm p-air}$ is found to be equal to $ 567.0 \\pm 70.5 [{\\rm Stat.}] ^{+25}_{-29} [{\\rm Sys.}]$ mb. The total proton-proton cross section is subsequently inferred from Glauber Formalism and Block, Halzen and Stanev QCD inspired fit and is found to be equal to $170_{-44}^{+48} [{\\rm Stat.}] \\pm _{-19}^{+1...

  15. MUDAL: a 4 pi multi-detector array in Lanzhou for charged particle detection at HIRFL

    CERN Document Server

    Li Song Lin; Jin Ge; Xu Hu Shan; Yin Xu; Wang Xiao Qiu; Li Zu Yu; Lu Jun

    2002-01-01

    A 4 pi multidetector array of measuring charged particle is described. It consists of 276 detector units, each unit composed of fast and slow plastic scintillator phoswiches, fast plastic scintillator and CsI(Tl) phoswiches and silicon detector telescopes. It covers geometrically 86% of the 4 pi solid angle and has very low detection thresholds. The detectors, operated under vacuum, is axially symmetric. sup 1 sup , sup 2 sup , sup 3 H, sup 3 sup , sup 4 He and the elements from Li to Ar can be identified and their energies measured over a large dynamic range

  16. Detector block based on arrays of 144 SiPMs and monolithic scintillators: A performance study

    Energy Technology Data Exchange (ETDEWEB)

    González, A.J.; Conde, P.; Iborra, A. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); Aguilar, A. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Bellido, P. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); García-Olcina, R. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Hernández, L.; Moliner, L.; Rigla, J.P.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Seimetz, M.; Soriano, A. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain); Torres, J. [Communications and Digital Systems Design Group (DSDC), Universidad de Valencia (Spain); Vidal, L.F.; Benlloch, J.M. [Institute for Instrumentation in Molecular Imaging (I3M), Universidad Politécnica de Valencia – CSIC – CIEMAT (Spain)

    2015-07-01

    We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12×12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured.

  17. Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report

    Energy Technology Data Exchange (ETDEWEB)

    Tim Roney; Robert Seifert; Bob Pink; Mike Smith

    2011-09-01

    The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integration into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.

  18. Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Gruner, Sol [Cornell Univ., Ithaca, NY (United States)

    2010-05-01

    The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

  19. THz Direct Detector and Heterodyne Receiver Arrays in Silicon Nanoscale Technologies

    Science.gov (United States)

    Grzyb, Janusz; Pfeiffer, Ullrich

    2015-10-01

    The main scope of this paper is to address various implementation aspects of THz detector arrays in the nanoscale silicon technologies operating at room temperatures. This includes the operation of single detectors, detectors operated in parallel (arrays), and arrays of detectors operated in a video-camera mode with an internal reset to support continuous-wave illumination without the need to synchronize the source with the camera (no lock-in receiver required). A systematic overview of the main advantages and limitations in using silicon technologies for THz applications is given. The on-chip antenna design challenges and co-design aspects with the active circuitry are thoroughly analyzed for broadband detector/receiver operation. A summary of the state-of-the-art arrays of broadband THz direct detectors based on two different operation principles is presented. The first is based on the non-quasistatic resistive mixing process in a MOSFET channel, whereas the other relies on the THz signal rectification by nonlinearity of the base-emitter junction in a high-speed SiGe heterojunction bipolar transistor (HBT). For the MOSFET detector arrays implemented in a 65 nm bulk CMOS technology, a state-of-the-art optical noise equivalent power (NEP) of 14 pW/ at 720 GHz was measured, whereas for the HBT detector arrays in a 0.25 μm SiGe process technology, an optical NEP of 47 pW/ at 700 GHz was found. Based on the implemented 1k-pixel CMOS camera with an average power consumption of 2.5 μW/pixel, various design aspects specific to video-mode operation are outlined and co-integration issues with the readout circuitry are analyzed. Furthermore, a single-chip 2 × 2 array of heterodyne receivers for multi-color active imaging in a 160-1000 GHz band is presented with a well-balanced NEP across the operation bandwidth ranging from 0.1 to 0.24 fW/Hz (44.1-47.8 dB single-sideband NF) and an instantaneous IF bandwidth of 10 GHz. In its present implementation, the receiver RF

  20. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  1. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy.

    Science.gov (United States)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  2. Classifying Two-dimensional Hyporeductive Triple Algebras

    CERN Document Server

    Issa, A Nourou

    2010-01-01

    Two-dimensional real hyporeductive triple algebras (h.t.a.) are investigated. A classification of such algebras is presented. As a consequence, a classification of two-dimensional real Lie triple algebras (i.e. generalized Lie triple systems) and two-dimensional real Bol algebras is given.

  3. Two-dimensional function photonic crystals

    CERN Document Server

    Wu, Xiang-Yao; Liu, Xiao-Jing; Liang, Yu

    2016-01-01

    In this paper, we have firstly proposed two-dimensional function photonic crystals, which the dielectric constants of medium columns are the functions of space coordinates $\\vec{r}$, it is different from the two-dimensional conventional photonic crystals constituting by the medium columns of dielectric constants are constants. We find the band gaps of two-dimensional function photonic crystals are different from the two-dimensional conventional photonic crystals, and when the functions form of dielectric constants are different, the band gaps structure should be changed, which can be designed into the appropriate band gaps structures by the two-dimensional function photonic crystals.

  4. Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA

    Energy Technology Data Exchange (ETDEWEB)

    Hueyuek, Tayfun; Gadea, Andres; Domingo-Pardo, Cesar [Universidad de Valencia, Instituto de Fisica Corpuscular, CSIC, Paterna (Valencia) (Spain); Di Nitto, Antonio [Istituto Nazionale di Fisica Nucleare, Napoli (Italy); Johannes Gutenberg-Universitaet Mainz, Mainz (Germany); Jaworski, Grzegorz; Javier Valiente-Dobon, Jose; De Angelis, Giacomo; Modamio, Victor; Triossi, Andrea [Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Legnaro (Italy); Nyberg, Johan [Uppsala University, Department of Physics and Astronomy, Uppsala (Sweden); Palacz, Marcin [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); Soederstroem, Paer-Anders [RIKEN Nishina Center, Saitama (Japan); Aliaga-Varea, Ramon Jose [Universidad de Valencia, Instituto de Fisica Corpuscular, CSIC, Paterna (Valencia) (Spain); Universidad Politecnica de Valencia, I3M, Valencia (Spain); Atac, Ayse [Ankara University, Department of Physics, Faculty of Sciences, Ankara (Turkey); The Royal Institute of Technology, Stockholm (Sweden); Collado, Javier; Egea, Francisco Javier; Gonzalez, Vicente; Sanchis, Enrique [University of Valencia, Department of Electronic Engineering, Burjassot (Valencia) (Spain); Erduran, Nizamettin [Istanbul Sabahattin Zaim University, Faculty of Engineering and Natural Sciences, Istanbul (Turkey); Ertuerk, Sefa [University of Nigde, Department of Physics, Faculty of Science and Arts, Nigde (Turkey); France, Gilles de [CNRS/IN2P3, GANIL, CEA/DSAM, Caen (France); Gadea, Rafael; Herrero-Bosch, Vicente [Universidad Politecnica de Valencia, I3M, Valencia (Spain); Kaskas, Ayse [Ankara University, Department of Physics, Faculty of Sciences, Ankara (Turkey); Moszynski, Marek [National Centre for Nuclear Research, Otwock-Swierk (Poland); Wadsworth, Robert [University of York, Department of Physics, York (United Kingdom)

    2016-03-15

    The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large γ -ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23l and it is filled with the EJ301 liquid scintillator, that presents good neutron- γ discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the {sup 58}Ni + {sup 56}Fe reaction measured with the Neutron Wall detector array. (orig.)

  5. Characterization of thermal cross-talk in a MEMS-based thermopile detector array

    NARCIS (Netherlands)

    Wu, H.; Grabarnik, S.; Emadi, A.; De Graaf, G.; Wolffenbuttel, R.F.

    2009-01-01

    The spectral resolution of a MEMS-based IR microspectrometer critically depends on the thermal cross-talk between adjacent TE elements in the detector array. Thermal isolation between elements is realized by using bulk micromachining directly following CMOS processing. This paper reports on the char

  6. First Data with the Hybrid Array of Gamma-Ray Detectors (HAGRiD)

    Science.gov (United States)

    Smith, Karl; Burcher, S.; Carter, A. B.; Gryzwacz, R.; Jones, K. L.; Munoz, S.; Paulauskas, S. V.; Schmitt, K.; Thornsberry, C.; Chipps, K. A.; Febbraro, M.; Pain, S. D.; Baugher, T.; Cizewski, J. A.; Ratkiewicz, A.; Toomey, B.

    2016-09-01

    The structure of nuclei provides insight into astrophysical reaction rates that are difficult to measure directly. These studies are often performed with transfer reaction and beta-decay measurements. These experiments benefit from particle-gamma coincident measurements providing information beyond that of particle detection alone. The Hybrid Array of Gamma Ray Detectors (HAGRiD) of LaBr3(Ce) scintillators has been designed with this purpose in mind. The design of the array permits it to be coupled with particle detector systems, such as the Oak Ridge Rutgers University Barrel Array (ORRUBA) of silicon detectors and the Versatile Array of Neutron Detectors at Low Energy (VANDLE). It is also designed to operate with the Jet Experiments in Nuclear Structure and Astrophysics (JENSA) advanced target system. HAGRiD's design avoids compromising the charged-particle angular resolution due to compact geometries often used to increase the gamma efficiency in other systems. First experimental data with HAGRiD coupled to VANDLE as well as ORRUBA and JENSA will be presented. This work is supported in part by the U.S. Department of Energy, Office of Science Nuclear Physics and the National Science Foundation.

  7. Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA

    Science.gov (United States)

    Hüyük, Tayfun; Di Nitto, Antonio; Jaworski, Grzegorz; Gadea, Andrés; Javier Valiente-Dobón, José; Nyberg, Johan; Palacz, Marcin; Söderström, Pär-Anders; Jose Aliaga-Varea, Ramon; de Angelis, Giacomo; Ataç, Ayşe; Collado, Javier; Domingo-Pardo, Cesar; Egea, Francisco Javier; Erduran, Nizamettin; Ertürk, Sefa; de France, Gilles; Gadea, Rafael; González, Vicente; Herrero-Bosch, Vicente; Kaşkaş, Ayşe; Modamio, Victor; Moszynski, Marek; Sanchis, Enrique; Triossi, Andrea; Wadsworth, Robert

    2016-03-01

    The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large γ-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23l and it is filled with the EJ301 liquid scintillator, that presents good neutron- γ discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the 58Ni + 56Fe reaction measured with the Neutron Wall detector array.

  8. Development of Yangbajing Air shower Core detector array for a new EAS hybrid Experiment

    CERN Document Server

    Liu, Jinsheng; Chen, Ding; Zhang, Ying; Zhai, Liuming; Chen, Xu; Hu, Xiaobin; Lin, Yuhui; Zhang, Xueyao; Feng, Cunfeng; Jia, Huanyu; Zhou, Xunxiu; DanZengLuoBu,; Chen, Tianlu; Li, Haijin; Liu, Maoyuan; Yuan, Aifang

    2015-01-01

    Aiming at the observation of cosmic-ray chemical composition at the "knee" energy region, we have been developinga new type air-shower core detector (YAC, Yangbajing Air shower Core detector array) to be set up at Yangbajing (90.522$^\\circ$ E, 30.102$^\\circ$ N, 4300 m above sea level, atmospheric depth: 606 g/m$^2$) in Tibet, China. YAC works together with the Tibet air-shower array (Tibet-III) and an underground water cherenkov muon detector array (MD) as a hybrid experiment. Each YAC detector unit consists of lead plates of 3.5 cm thick and a scintillation counter which detects the burst size induced by high energy particles in the air-shower cores. The burst size can be measured from 1 MIP (Minimum Ionization Particle) to $10^{6}$ MIPs. The first phase of this experiment, named "YAC-I", consists of 16 YAC detectors each having the size 40 cm $\\times$ 50 cm and distributing in a grid with an effective area of 10 m$^{2}$. YAC-I is used to check hadronic interaction models. The second phase of the experiment,...

  9. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

    Science.gov (United States)

    Tate, Mark W; Purohit, Prafull; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2016-02-01

    We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

  10. Testing and assembly of the detectors for the Millimeter Bolometer Array Camera on ACT

    Science.gov (United States)

    Marriage, T. A.; Chervenak, J. A.; Doriese, W. B.

    2006-04-01

    The Millimeter Bolometer Array Camera (MBAC) for the Atacama Cosmology Telescope consists of three Transition Edge Sensor (TES) arrays to make simultaneous observations of the Cosmic Microwave Background in three frequency bands. MBAC TESs are NASA Goddard Pop-Up Detectors (PUD) which are read-out by NIST time-domain multiplexers. MBAC is constructed by stacking 1×32 TES columns to form the 32×32 element arrays. The arrays are modular (connectorized) at the 1×32 column level such that array assembly is reversible and camera repair possible. Prior to assembly, each column is tested in a quick (2h) cycling 4He/3He adsorption refrigerator. Tests include measurements of TES current voltage curves and TES complex impedance.

  11. Performance Measurements On A 32X32 InSb-CID Detector Array For Astronomical Observations

    Science.gov (United States)

    Tiphene, D.; Lacombe, F.; Rouan, D.

    1989-01-01

    The use at liquid helium temperature of a InSb-CID detector array differs significantly from opera-tion at conditions usually adopted by the manufacturer (77K). In particular, the dark current behaviour hugely changes between the two temperatures. Only the tunnel current, independant of temperature conditions, is still active at 4.2K while the thermal-family currents vanish. We have studied the tunnel current of one InSb-MIS detector to determine its suitability to the low background conditions that will be met in the space experiment ISO. The search for the maximum integration time and the best quantum efficiency, the constraint about the photonic response linearity (especially at low photon flux), and the reduction of the readout noise constitute the main points of this study. Moreover, laboratory measurements showed secondary effects due to the detector (lag) or to the wiring (crosstalk). The CID array reactions to high energy radiations (Gamma rays) are finally discussed.

  12. Multiple detector focal plane array ultraviolet spectrometer for the AMPS laboratory

    Science.gov (United States)

    Feldman, P. D.

    1975-01-01

    The possibility of meeting the requirements of the amps spectroscopic instrumentation by using a multi-element focal plane detector array in a conventional spectrograph mount was examined. The requirements of the detector array were determined from the optical design of the spectrometer which in turn depends on the desired level of resolution and sensitivity required. The choice of available detectors and their associated electronics and controls was surveyed, bearing in mind that the data collection rate from this system is so great that on-board processing and reduction of data are absolutely essential. Finally, parallel developments in instrumentation for imaging in astronomy were examined, both in the ultraviolet (for the Large Space Telescope as well as other rocket and satellite programs) and in the visible, to determine what progress in that area can have direct bearing on atmospheric spectroscopy.

  13. ZnMgO Nanowire Based Detectors and Detector Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this STTR program, Structured Materials Industries (SMI) and partners propose to develop an electrically contacted zinc magnesium oxide (ZnMgO) nanowire array for...

  14. Multiplexed Readout of MMC Detector Arrays Using Non-hysteretic rf-SQUIDs

    Science.gov (United States)

    Kempf, S.; Wegner, M.; Gastaldo, L.; Fleischmann, A.; Enss, C.

    2014-08-01

    Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to X-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQUID multiplexer that employs non-hysteretic rf-SQUIDs to create a frequency shift of high resonators that is in accordance with the detector signal and that can be monitored by using standard microwave measurement techniques. In this paper we discuss the design of a recently developed and fabricated 64 pixel detector array with integrated microwave SQUID multiplexer that was produced to test the suitability of this readout technique. The characterization of dc-SQUIDs with virtually identical washer design compared to the rf-SQUIDs of the SQUID multiplexer revealed that the crucial SQUID parameters such as the critical current of the Josephson junctions or the washer inductance are close to the design values and anticipates a successful operation of the SQUID multiplexer.

  15. InGaAs Schottky barrier diode array detectors integrated with broadband antenna (Conference Presentation)

    Science.gov (United States)

    Park, Dong Woo; Lee, Eui Su; Park, Jeong-Woo; Kim, Hyun-Soo; Lee, Il-Min; Park, Kyung Hyun

    2017-02-01

    Terahertz (THz) waves have been actively studied for the applications of astronomy, communications, analytical science and bio-technologies due to their low energy and high frequency. For example, THz systems can carry more information with faster rates than GHz systems. Besides, THz waves can be applied to imaging, sensing, and spectroscopy. Furthermore, THz waves can be used for non-destructive and non-harmful tomography of living objects. In this reasons, Schottky barrier diodes (SBD) have been widely used as a THz detector for their ultrafast carrier transport, high responsivity, high sensitivity, and excellent noise equivalent power. Furthermore, SBD detectors envisage developing THz applications at low cost, excellent capability, and high yield. Since the major concerns in the THz detectors for THz imaging systems are the realizations of the real-time image acquisitions via a reduced acquisition time, rather than the conventional raster scans that obtains an image by pixel-by-pixel acquisitions, a line-scan based systems utilizes an array detector with an 1 × n SBD array is preferable. In this study, we fabricated the InGaAs based SBD array detectors with broadband antennas of log-spiral and square-spiral patterns. To optimize leakage current and ideality factor, the dependence to the doping levels of ohmic and Schottky layers have been investigated. In addition, the dependence to the capacitance and resistance to anode size are also examined as well. As a consequence, the real-time THz imaging with our InGaAs SBD array detector have been successfully obtained.

  16. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500.

    Science.gov (United States)

    Stelljes, T S; Harmeyer, A; Reuter, J; Looe, H K; Chofor, N; Harder, D; Poppe, B

    2015-04-01

    The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm(2) measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array's readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor kNR for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array's central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1% over the range from 5 to 1000 MU. The

  17. Two dimensional convolute integers for machine vision and image recognition

    Science.gov (United States)

    Edwards, Thomas R.

    1988-01-01

    Machine vision and image recognition require sophisticated image processing prior to the application of Artificial Intelligence. Two Dimensional Convolute Integer Technology is an innovative mathematical approach for addressing machine vision and image recognition. This new technology generates a family of digital operators for addressing optical images and related two dimensional data sets. The operators are regression generated, integer valued, zero phase shifting, convoluting, frequency sensitive, two dimensional low pass, high pass and band pass filters that are mathematically equivalent to surface fitted partial derivatives. These operators are applied non-recursively either as classical convolutions (replacement point values), interstitial point generators (bandwidth broadening or resolution enhancement), or as missing value calculators (compensation for dead array element values). These operators show frequency sensitive feature selection scale invariant properties. Such tasks as boundary/edge enhancement and noise or small size pixel disturbance removal can readily be accomplished. For feature selection tight band pass operators are essential. Results from test cases are given.

  18. New detector array - the HRIBF Modular Total Absorption Spectrometer

    Science.gov (United States)

    Wolinska-Cichocka, Marzena; Rykaczewski, Krzysztof; Karny, Marek; Kuzniak, Aleksandra; Grzywacz, Robert; Rasco, Charlie; Miller, David; Gross, Carl J.; Johnson, Jim

    2011-10-01

    The construction of a new Modular Total Absorption Spectrometer (MTAS) at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory will be presented. The total absorption gamma spectra measured with MTAS will be used to derive a true beta-feeding pattern and resulting beta strength function for fission products. In particular, the measurements of decay heat released by radioactive nuclei produced in nuclear fuels at power reactors will be performed. MTAS is made up of 19 large NaI(Tl) crystals each encapsulated with a 0.8-mm-thick carbon fiber. There are also two 1-mm- thick Silicon Strip Detectors surrounding a moving tape collector that count beta-energy loss signals. The structure is shielded by more than 1-inch of lead around MTAS which reduces background radiation significantly. MTAS efficiency for full energy deposition of gamma ray approaches nearly 90% for 300 keV gammas and over 75% for a 5 MeV gamma transition. Research supported by the DOE Office of Nuclear Physics.

  19. MEGHNAD – A multi element detector array for heavy ion collision studies

    Indian Academy of Sciences (India)

    Satyajit Saha

    2001-07-01

    In the coming decade, the expanding field of experimental nuclear physics in our country is going to see a quantum leap in research and developmental activities with new accelerator facilities like the variable energy cyclotron with ECR heavy ion source, the upcoming K-500 superconducting cyclotron, both at VECC, Calcutta, and the superconducting linac boosters at both the Pelletron Accelerator Facilities at TIFR, Mumbai and NSC, New Delhi. When heavy ion beam available from such machines fall on a target and undergo collision, very rich and often pristine fields of research open up. In order to carry on such activities, we have taken up a project to build a multi element gamma, heavy ion and neutron array of detectors (MEGHNAD) to detect and study the properties of a wide variety of particles like neutrons, protons, light mass clusters, massive ejected fragments, and gamma rays with good solid angle coverage and efficiency. Design of the detector array, performance of the prototype detector and brief outline of the research programme to be undertaken with the detector array will be discussed.

  20. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy

    CERN Document Server

    Tate, Mark W; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert M; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2015-01-01

    We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as loc...

  1. Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors

    CERN Document Server

    van Rantwijk, Joris; van Loon, Dennis; Yates, Stephen; Baryshev, Andrey; Baselmans, Jochem

    2015-01-01

    Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per readout line. We describe a novel readout system for large arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout, which is a combination of a digital front- and back-end and an analog up- and down-converter system, can read out up to 4000 detectors simultaneously with 1 kHz datarate. The system achieves a readout noise power spectral density of -98 dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN MKIDs can be read out without deteriorating their intrinsic performance.

  2. The performance of a prototype array of water Cherenkov detectors for the LHAASO project

    Energy Technology Data Exchange (ETDEWEB)

    An, Q. [University of Science and Technology of China, Hefei 230026 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Bai, Y.X.; Bi, X.J.; Cao, Z. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chang, J.F. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Chen, G.; Chen, M.J. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, S.M. [Tsinghua University, Beijing 100084 (China); Chen, S.Z. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, T.L. [University of Tibet, Lhasa 851600 (China); Chen, X. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Y.T. [University of Yunnan, Kunming 650091 (China); Cui, S.W. [Normal University of Hebei, Shijiazhuang 050016 (China); Dai, B.Z. [University of Yunnan, Kunming 650091 (China); Du, Q. [Tsinghua University, Beijing 100084 (China); Danzengluobu [University of Tibet, Lhasa 851600 (China); Feng, C.F. [University of Shandong, Jinan 250100 (China); Feng, S.H.; Gao, B. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Gao, S.Q. [National Space Science Center, Chinese Academy of Sciences, Beijing 100190 (China); and others

    2013-10-01

    A large high-altitude air-shower observatory (LHAASO) is to be built at Shangri-La, Yunnan Province, China. This observatory is intended to conduct sub-TeV gamma astronomy, and as an important component of the LHAASO project, a water Cherenkov detector array (WCDA) is proposed. To investigate engineering issues and fully understand the water Cherenkov technique for detecting air showers, a prototype array at 1% scale of the LHAASO-WCDA has been built at Yang-Ba-Jing, Tibet, China. This paper introduces the prototype array setup and studies its performance by counting rate of each photomultiplier tube (PMT), trigger rates at different PMT multiplicities, and responses to air showers. Finally, the reconstructed shower directions and angular resolutions of the detected showers for the prototype array are given. -- Highlights: • The technique of the water Cherenkov array is studied. • Engineering issues of the water Cherenkov array are investigated. • The PMTs and electronics of the water Cherenkov array are tested. • Some key parameters of the water Cherenkov array are measured.

  3. High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector

    Science.gov (United States)

    Giewekemeyer, Klaus; Philipp, Hugh T.; Wilke, Robin N.; Aquila, Andrew; Osterhoff, Markus; Tate, Mark W.; Shanks, Katherine S.; Zozulya, Alexey V.; Salditt, Tim; Gruner, Sol M.; Mancuso, Adrian P.

    2014-01-01

    Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 108 8-keV photons pixel−1 s−1, and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 1010 photons µm−2 s−1 within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while ‘still’ images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described. PMID:25178008

  4. Hadamard States and Two-dimensional Gravity

    CERN Document Server

    Salehi, H

    2001-01-01

    We have used a two-dimensional analog of the Hadamard state-condition to study the local constraints on the two-point function of a linear quantum field conformally coupled to a two-dimensional gravitational background. We develop a dynamical model in which the determination of the state of the quantum field is essentially related to the determination of a conformal frame. A particular conformal frame is then introduced in which a two-dimensional gravitational equation is established.

  5. Topological defects in two-dimensional crystals

    OpenAIRE

    Chen, Yong; Qi, Wei-Kai

    2008-01-01

    By using topological current theory, we study the inner topological structure of the topological defects in two-dimensional (2D) crystal. We find that there are two elementary point defects topological current in two-dimensional crystal, one for dislocations and the other for disclinations. The topological quantization and evolution of topological defects in two-dimensional crystals are discussed. Finally, We compare our theory with Brownian-dynamics simulations in 2D Yukawa systems.

  6. Multiplexed readout demonstration of a TES-based detector array in a resistance locked loop

    CERN Document Server

    van der Kuur, Jan; Kiviranta, Mikko; Akamatsu, Hiroki; Khosropanah, Pourya; Hartog, Roland den; Suzuki, Toyoaki; Jackson, Brian

    2015-01-01

    TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the instruments. In an effort to improve the properties of TES-based detectors, fixing the TES resistance in a resistance-locked loop (RLL) under optical loading has recently been proposed. Earlier theoretical work on this mode of operation has shown that the detector speed, linearity and dynamic range should improve with respect to voltage biased operation. This paper presents an experimental demonstration of multiplexed readout in this mode of operation in a TES-based detector array with noise equivalent power values (NEP) of $3.5\\cdot 10^{-19} $W/$\\sqrt{\\mathrm{Hz}}$. The measured noise and dynamic properties of the detector in the RLL will be compared with the earlier modelling work. Furthermore, the practical implementation routes for future FDM systems for the readout of ...

  7. Photoacoustic projection imaging using a 64-channel fiber optic detector array

    Science.gov (United States)

    Bauer-Marschallinger, Johannes; Felbermayer, Karoline; Bouchal, Klaus-Dieter; Veres, Istvan A.; Grün, Hubert; Burgholzer, Peter; Berer, Thomas

    2015-03-01

    In this work we present photoacoustic projection imaging with a 64-channel integrating line detector array, which average the pressure over cylindrical surfaces. For imaging, the line detectors are arranged parallel to each other on a cylindrical surface surrounding a specimen. Thereby, the three-dimensional imaging problem is reduced to a twodimensional problem, facilitating projection imaging. After acquisition of a dataset of pressure signals, a twodimensional photoacoustic projection image is reconstructed. The 64 channel line detector array is realized using optical fibers being part of interferometers. The parts of the interferometers used to detect the ultrasonic pressure waves consist of graded-index polymer-optical fibers (POFs), which exhibit better sensitivity than standard glass-optical fibers. Ultrasonic waves impinging on the POFs change the phase of light in the fiber-core due to the strain-optic effect. This phase shifts, representing the pressure signals, are demodulated using high-bandwidth balanced photo-detectors. The 64 detectors are optically multiplexed to 16 detection channels, thereby allowing fast imaging. Results are shown on a Rhodamine B dyed microsphere.

  8. A novel, SiPM-array-based, monolithic scintillator detector for PET.

    Science.gov (United States)

    Schaart, Dennis R; van Dam, Herman T; Seifert, Stefan; Vinke, Ruud; Dendooven, Peter; Löhner, Herbert; Beekman, Freek J

    2009-06-07

    Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce(3+) crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an approximately 0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 degrees , demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF(2) detector, equals 960 ps FWHM.

  9. Assessment of array scintillation detector for follicle thyroid 2-D image acquisition using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos Borges da; Santanna, Claudio Reis de [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: borges@ien.gov.br; santanna@ien.gov.br; Braz, Delson [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Instrumentacao Nuclear]. E-mail: delson@lin.ufrj.br; Carvalho, Denise Pires de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Biofisica Carlos Chagas Filho. Lab. de Fisiologia Endocrina]. E-mail: dencarv@ufrj.br

    2007-07-01

    This work presents an innovative study to find out the adequate scintillation inorganic detector array to be used coupled to a specific light photo sensor, a charge coupled device (CCD), through a fiber optic plate. The goal is to choose the type of detector that fits a 2-dimensional imaging acquisition of a cell thyroid tissue application with high resolution and detection efficiency in order to map a follicle image using gamma radiation emission. A point or volumetric source - detector simulation by using a MCNP4B general code, considering different source energies, detector materials and geometry including pixel sizes and reflector types was performed. In this study, simulations were performed for 7 x 7 and 127 x 127 arrays using CsI(Tl) and BGO scintillation crystals with pixel size ranging from 1 x 1 cm{sup 2} to 10 x 10 {mu}m{sup 2} and radiation thickness ranging from 1 mm to 10 mm. The effect of all these parameters was investigated to find the best source-detector system that result in an image with the best contrast details. The results showed that it is possible to design a specific imaging system that allows searching for in-vitro studies, specifically in radiobiology applied to endocrine physiology. (author)

  10. A novel, SiPM-array-based, monolithic scintillator detector for PET

    Energy Technology Data Exchange (ETDEWEB)

    Schaart, Dennis R; Dam, Herman T van; Seifert, Stefan; Beekman, Freek J [Delft University of Technology, Radiation Detection and Medical Imaging, Mekelweg 15, 2629 JB Delft (Netherlands); Vinke, Ruud; Dendooven, Peter; Loehner, Herbert [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, 9747 AA, Groningen (Netherlands)], E-mail: d.r.schaart@tudelft.nl

    2009-06-07

    Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce{sup 3+} crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an {approx}0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 deg., demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF{sub 2} detector, equals 960 ps FWHM.

  11. X-ray Characterization of a Multichannel Smart-Pixel Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Steve; Haji-Sheikh, Michael; Huntington, Andrew; Kline, David; Lee, Adam; Li, Yuelin; Rhee, Jehyuk; Tarpley, Mary; Walko, Donald A.; Westberg, Gregg; Williams, George; Zou, Haifeng; Landahl, Eric

    2016-01-01

    The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

  12. Study on simulation and experiment of array micro Faraday cup ion detector for FAIMS

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    An array micro Faraday cup ion detector for FAIMS (High-field Asymmetric Waveform Ion Mobility Spectrometry) was introduced, with which the size of the FAIMS system was reduced. With simple structure, good stability, low noise, large measurements range, this detector can work under the condition of atmospheric pressure. The array micro Faraday cup was composed of gate electrode, sensitive electrode and shielding electrode. The sensitive electrode was made of tens of crossing silicon columns with diameter of 200 μm. It was fabricated through typical MEMS technology, which was compatible completely with plane FAIMS. It was shown from FLUENT simulation result that the resistance to gas motion was low and the flow field distribution was helpful for full absorption of the ion in this array design. Through electricity simulation, the method to reduce interference on the detection signal of the micro Faraday cup was given out. Connecting with KEITHLEY 237 ampere meter, the noise level of the array micro Faraday cup was lower than 0.5 pA. The output signal of the acetone sample measured by experiment was about 210 pA. Through contrast experiment, the design parameter of the micro Faraday cup was obtained primarily. This array micro Faraday cup can meet the requirements of the FAIMS system.

  13. Neutron-induced reaction cross-section measurements using a small multi-detector array and description of a large array

    Indian Academy of Sciences (India)

    J-P Meulders; I Slypen; S Benck; E Raeymackers; J Cabrera; Ch Dufauquez; T Keutgen; V Roberfroid; I Tilquin; Y El Masri; V Corcalciuc; N Nice

    2001-07-01

    The experimental setup of Louvain-la-Neuve (UCL-Belgium) used to perform lightcharged particle production experiment in fast neutron-induced reactions is presented. A short description of the neutron modular detector DEMON is also given. DEMON is a detector array for neutrons emitted in heavy ion induced reactions at low to intermediate energies.

  14. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500

    Energy Technology Data Exchange (ETDEWEB)

    Stelljes, T. S., E-mail: tenzin.s.stelljes@uni-oldenburg.de; Looe, H. K.; Chofor, N.; Poppe, B. [Clinic for Radiation Therapy, Pius-Hospital, Oldenburg 26121, Germany and WG Medical Radiation Physics, Carl von Ossietzky University, Oldenburg 26129 (Germany); Harmeyer, A.; Reuter, J. [WG Medical Radiation Physics, Carl von Ossietzky University, Oldenburg 26129 (Germany); Harder, D. [Prof. em., Medical Physics and Biophysics, Georg August University, Göttingen 37073 (Germany)

    2015-04-15

    Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1

  15. Materials preparation and fabrication of pyroelectric polymer/silicon MOSFET detector arrays. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomfield, P. [Drexel Univ., Philadelphia, PA (United States). Dept. of Materials Engineering

    1992-03-27

    The authors have delivered several 64-element linear arrays of pyroelectric elements fully integrated on silicon wafers with MOS readout devices. They have delivered detailed drawings of the linear arrays to LANL. They have processed a series of two inch wafers per submitted design. Each two inch wafer contains two 64 element arrays. After spin-coating copolymer onto the arrays, vacuum depositing the top electrodes, and polarizing the copolymer films so as to make them pyroelectrically active, each wafer was split in half. The authors developed a thicker oxide coating separating the extended gate electrode (beneath the polymer detector) from the silicon. This should reduce its parasitic capacitance and hence improve the S/N. They provided LANL three processed 64 element sensor arrays. Each array was affixed to a connector panel and selected solder pads of the common ground, the common source voltage supply connections, the 64 individual drain connections, and the 64 drain connections (for direct pyroelectric sensing response rather than the MOSFET action) were wire bonded to the connector panel solder pads. This entails (64 + 64 + 1 + 1) = 130 possible bond connections per 64 element array. This report now details the processing steps and the progress of the individual wafers as they were carried through from beginning to end.

  16. Investigation of Very Fast Light Detectors: Silicon Photomultiplier and Micro PMT for a Cosmic Ray Array

    Science.gov (United States)

    Cervantes, Omar; Reyes, Liliana; Hooks, Tyler; Perez, Luis; Ritt, Stefan

    2016-03-01

    To construct a cosmic detector array using 4 scintillation detectors, we investigated 2 recent light sensor technologies from Hamamatsu, as possible readout detectors. First, we investigated several homemade versions of the multipixel photon counter (MPPC) light sensors. These detectors were either biased with internal or external high voltage power supplies. We made extensive measurements to confirm for the coincidence of the MPPC devices. Each sensor is coupled to a wavelength shifting fiber (WSF) that is embedded along a plastic scintillator sheet (30cmx60cmx1/4''). Using energetic cosmic rays, we evaluated several of these homemade detector modules placed above one another in a light proof enclosure. Next, we assembled 2 miniaturized micro photomultiplier (micro PMT), a device recently marketed by Hamamatsu. These sensors showed very fast response times. With 3 WSF embedded in scintillator sheets, we performed coincidence experiments. The detector waveforms were captured using the 5GS/sec domino ring sampler, the DRS4 and our workflow using the CERN PAW package and data analysis results would be presented. Title V Grant.

  17. Quantum efficiency performances of the NIR European Large Format Array detectors tested at ESTEC

    Science.gov (United States)

    Crouzet, P.-E.; Duvet, L.; de Wit, F.; Beaufort, T.; Blommaert, S.; Butler, B.; Van Duinkerken, G.; ter Haar, J.; Heijnen, J.; van der Luijt, K.; Smit, H.

    2015-10-01

    Publisher's Note: This paper, originally published on 10/12/2015, was replaced with a corrected/revised version on 10/23/2015. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance. The Payload Technology Validation Section (SRE-FV) at ESTEC has the goal to validate new technology for future or on-going mission. In this framework, a test set up to characterize the quantum efficiency of near-infrared (NIR) detectors has been created. In the context of the NIR European Large Format Array ("LFA"), 3 deliverables detectors coming from SELEX-UK/ATC (UK) on one side, and CEA/LETI- CEA/IRFU-SOFRADIR (FR) on the other side were characterized. The quantum efficiency of an HAWAII-2RG detector from Teledyne was as well measured. The capability to compare on the same setup detectors from different manufacturers is a unique asset for the future mission preparation office. This publication will present the quantum efficiency results of a HAWAII-2RG detector from Teledyne with a 2.5um cut off compared to the LFA European detectors prototypes developed independently by SELEX-UK/ATC (UK) on one side, and CEA/LETI- CEA/IRFU-SOFRADIR (FR) on the other side.

  18. Underground Water Cherenkov Muon Detector Array with the Tibet Air Shower Array for Gamma-Ray Astronomy in the 100 TeV Region

    CERN Document Server

    Amenomori, M; Bi, X J; Chen, D; Cui, S W; Feng Zhao Yang; Danzengluobu; Ding, L K; Feng Cun Feng; Feng, Z; Feng, Z Y; Gao, X Y; Geng, Q X; Guo, H W; He, H H; He, M; Hibino, K; Hotta, N; Haibing, H; Hu, H B; Huang, J; Jia, H Y; Kajino, F; Kasahara, K; Katayose, Y; Kato, C; Kawata, K; Labaciren; Le, G M; Li, A F; Li, J Y; Lü, H; Lu, S L; Meng, X R; Mizutani, K; Mu, J; Munakata, K; Nagai, A; Nanj, H; Nishizawa, M; Ohnishi, M; Ohta, I; Onuma, H; Ouchi, T; Ozawa, S; Ren, J R; Saitô, T; Saito, T Y; Sakata, M; Sako, T K; Sasaki, T; Shibata, M; Shiomi, A; Shirai, T; Sugimoto, H; Takita, M; Tan, Y H; Tateyama, N; Tori, S; Wang, B; Tsuchiya, H; Udo, S; Wang, X; Wang, Y G; Wu, H R; Xue Liang; Yamamoto, Y; Yan, C T; Yang, X C; Yasue, S; Ye, Z H; Yu, G C; Yuan, A F; Yuda, T; Zhang, H M; Zhamg, N J; Zhamg, X, Y; Zhamg, Y; Zhamg, Yi; Zha Xisang Zhu; Zhou, X X; al, et

    2006-01-01

    We propose to build a large water-Cherenkov-type muon-detector array (Tibet MD array) around the 37,000 m$^{2}$ Tibet air shower array (Tibet AS array) already constructed at 4,300 m above sea level in Tibet, China. Each muon detector is a waterproof concrete pool, 6 m wide $\\times$ 6 m long $\\times$ 1.5 m deep in size, equipped with a 20 inch-in-diameter PMT. The Tibet MD array consists of 240 muon detectors set up 2.5 m underground. Its total effective area will be 8,640 m$^{2}$ for muon detection. The Tibet MD array will significantly improve gamma-ray sensitivity of the Tibet AS array in the 100 TeV region (10-1000 TeV) by means of gamma/hadron separation based on counting the number of muons accompanying an air shower. The Tibet AS+MD array will have the sensitivity to gamma rays in the 100 TeV region by an order of magnitude better than any other previous existing detectors in the world.

  19. Strongly interacting two-dimensional Dirac fermions

    NARCIS (Netherlands)

    Lim, L.K.; Lazarides, A.; Hemmerich, Andreas; de Morais Smith, C.

    2009-01-01

    We show how strongly interacting two-dimensional Dirac fermions can be realized with ultracold atoms in a two-dimensional optical square lattice with an experimentally realistic, inherent gauge field, which breaks time reversal and inversion symmetries. We find remarkable phenomena in a temperature

  20. Topology optimization of two-dimensional waveguides

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard; Sigmund, Ole

    2003-01-01

    In this work we use the method of topology optimization to design two-dimensional waveguides with low transmission loss.......In this work we use the method of topology optimization to design two-dimensional waveguides with low transmission loss....

  1. Feasibility Study for a Dual Field of View-Single Detector Array Infrared System.

    Science.gov (United States)

    1974-06-01

    the background is shown in Figure 2-8. In this system the field stop is scare I with a vertical slit and essentially all the energy falling on the...cylindrical mirror will be o focused as a vertical iine on the detector array. Several of the previous problems have been solved in this system. The...patterns Limillid only by DAC, AD,,.J Access y u, limited by speed. anid Display Mtsaitor strict possible formats. xalbe Modification of timing salto

  2. The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz detector array of bolometric polarimeters

    CERN Document Server

    Appel, John W; Amiri, Mandana; Araujo, Derek; Bennett, Charles L; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T; Colazo, Felipe; Crowe, Erik; Denis, Kevin; Dunner, Rolando; Eimer, Joseph; Essinger-Hileman, Thomas; Gothe, Dominik; Halpern, Mark; Harrington, Kathleen; Hilton, Gene; Hinshaw, Gary F; Huang, Caroline; Irwin, Kent; Jones, Glenn; Karakla, John; Kogut, Alan J; Larson, David; Limon, Michele; Lowry, Lindsay; Marriage, Tobias; Mehrle, Nicholas; Miller, Amber D; Miller, Nathan; Moseleyb, Samuel H; Novakh, Giles; Reintsemad, Carl; Rostemab, Karwan; Stevensonb, Thomas; Towner, Deborah; U-Yen, Kongpop; Wagner, Emily; Watts, Duncan; Wollack, Edward; Xu, Zhilei; Zeng, Lingzhen

    2014-01-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  3. The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz Detector Array of Bolometric Polarimeters

    Science.gov (United States)

    Appel, John W.; Ali, Aamir; Amiri, Mandana; Araujo, Derek; Bennett, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T.; Colazo, Felipe; Crowe, Erik; Denis, Kevin; Dunner, Rolando; Eimer, Joseph; Essinger-Hileman, Thomas; Gothe, Dominik; Halpern, Mark; Harrington, Kathleen; Kogut, Alan J..; Miller, Nathan; Moseley, Samuel H.; Stevenson, Thomas; Towner, Deborah; U-Yen, Kongpop; Wollack, Edward

    2014-01-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  4. Acoustic Bloch oscillations in a two-dimensional phononic crystal.

    Science.gov (United States)

    He, Zhaojian; Peng, Shasha; Cai, Feiyan; Ke, Manzhu; Liu, Zhengyou

    2007-11-01

    We report the observation of acoustic Bloch oscillations at megahertz frequency in a two-dimensional phononic crystal. By creating periodically arrayed cavities with a decreasing gradient in width along one direction in the phononic crystal, acoustic Wannier-Stark ladders are created in the frequency domain. The oscillatory motion of an incident Gaussian pulse inside the sample is demonstrated by both simulation and experiment.

  5. Lung counting: comparison of detector performance with a four detector array that has either metal or carbon fibre end caps, and the effect on mda calculation.

    Science.gov (United States)

    Ahmed, Asm Sabbir; Hauck, Barry; Kramer, Gary H

    2012-08-01

    This study described the performance of an array of high-purity Germanium detectors, designed with two different end cap materials-steel and carbon fibre. The advantages and disadvantages of using this detector type in the estimation of the minimum detectable activity (MDA) for different energy peaks of isotope (152)Eu were illustrated. A Monte Carlo model was developed to study the detection efficiency for the detector array. A voxelised Lawrence Livermore torso phantom, equipped with lung, chest plates and overlay plates, was used to mimic a typical lung counting protocol with the array of detectors. The lung of the phantom simulated the volumetric source organ. A significantly low MDA was estimated for energy peaks at 40 keV and at a chest wall thickness of 6.64 cm.

  6. Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

    Science.gov (United States)

    Peters, W. A.; Ilyushkin, S.; Madurga, M.; Matei, C.; Paulauskas, S. V.; Grzywacz, R. K.; Bardayan, D. W.; Brune, C. R.; Allen, J.; Allen, J. M.; Bergstrom, Z.; Blackmon, J.; Brewer, N. T.; Cizewski, J. A.; Copp, P.; Howard, M. E.; Ikeyama, R.; Kozub, R. L.; Manning, B.; Massey, T. N.; Matos, M.; Merino, E.; O'Malley, P. D.; Raiola, F.; Reingold, C. S.; Sarazin, F.; Spassova, I.; Taylor, S.; Walter, D.

    2016-11-01

    The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom GEANT4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. A low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

  7. A Noble Gas Detector with Electroluminescence Readout based on an Array of APDs

    CERN Document Server

    Bourguille, B; Gil-Botella, I; Lux, T; Palomares, C; Sanchez, F; Santorelli, R

    2015-01-01

    We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position measurements simultaneously. Measurements were performed in xenon (3.8 bar) and argon (4.8 bar) showing a good energy resolution of 5.3% FWHM at 60 keV in xenon and 9.4% in argon respectively. In X-ray energies of 13 could be clearly separated from the pedestals indicating that this kind of technology might be also interesting for dark matter detectors. Following Monte Carlo studies the performance could be improved significantly by reducing the pitch between the sensors.

  8. Development of arrays of Silicon Drift Detectors and readout ASIC for the SIDDHARTA experiment

    Science.gov (United States)

    Quaglia, R.; Schembari, F.; Bellotti, G.; Butt, A. D.; Fiorini, C.; Bombelli, L.; Giacomini, G.; Ficorella, F.; Piemonte, C.; Zorzi, N.

    2016-07-01

    This work deals with the development of new Silicon Drift Detectors (SDDs) and readout electronics for the upgrade of the SIDDHARTA experiment. The detector is based on a SDDs array organized in a 4×2 format with each SDD square shaped with 64 mm2 (8×8) active area. The total active area of the array is therefore 32×16 mm2 while the total area of the detector (including 1 mm border dead area) is 34 × 18mm2. The SIDDHARTA apparatus requires 48 of these modules that are designed and manufactured by Fondazione Bruno Kessler (FBK). The readout electronics is composed by CMOS preamplifiers (CUBEs) and by the new SFERA (SDDs Front-End Readout ASIC) circuit. SFERA is a 16-channels readout ASIC designed in a 0.35 μm CMOS technology, which features in each single readout channel a high order shaping amplifier (9th order Semi-Gaussian complex-conjugate poles) and a high efficiency pile-up rejection logic. The outputs of the channels are connected to an analog multiplexer for the external analog to digital conversion. An on-chip 12-bit SAR ADC is also included. Preliminary measurements of the detectors in the single SDD format are reported. Also measurements of low X-ray energies are reported in order to prove the possible extension to the soft X-ray range.

  9. High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector

    Energy Technology Data Exchange (ETDEWEB)

    Giewekemeyer, Klaus, E-mail: klaus.giewekemeyer@xfel.eu [European XFEL GmbH, Hamburg (Germany); Philipp, Hugh T. [Cornell University, Ithaca, NY (United States); Wilke, Robin N. [Georg-August-Universität Göttingen, Göttingen (Germany); Aquila, Andrew [European XFEL GmbH, Hamburg (Germany); Osterhoff, Markus [Georg-August-Universität Göttingen, Göttingen (Germany); Tate, Mark W.; Shanks, Katherine S. [Cornell University, Ithaca, NY (United States); Zozulya, Alexey V. [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Salditt, Tim [Georg-August-Universität Göttingen, Göttingen (Germany); Gruner, Sol M. [Cornell University, Ithaca, NY (United States); Cornell University, Ithaca, NY (United States); Kavli Institute of Cornell for Nanoscience, Ithaca, NY (United States); Mancuso, Adrian P. [European XFEL GmbH, Hamburg (Germany)

    2014-08-07

    The advantages of a novel wide dynamic range hard X-ray detector are demonstrated for (ptychographic) coherent X-ray diffractive imaging. Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 10{sup 8} 8-keV photons pixel{sup −1} s{sup −1}, and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 10{sup 10} photons µm{sup −2} s{sup −1} within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while ‘still’ images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.

  10. High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

    Energy Technology Data Exchange (ETDEWEB)

    Philipp, Hugh T., E-mail: htp2@cornell.edu; Tate, Mark W.; Purohit, Prafull; Shanks, Katherine S.; Weiss, Joel T. [Cornell University, Ithaca, NY 14853 (United States); Gruner, Sol M. [Cornell University, Ithaca, NY 14853 (United States); Cornell University, Ithaca, NY 14853 (United States)

    2016-01-28

    A high-speed pixel array detector for time-resolved X-ray imaging at synchrotrons has been developed. The ability to isolate single synchrotron bunches makes it ideal for time-resolved dynamical studies. A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. The characteristics, operation, testing and application of the detector are detailed.

  11. Mercuric iodide room-temperature array detectors for gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Patt, B. [Xsirius, Inc, Camarillo, CA (United States)

    1994-11-15

    Significant progress has been made recently in the development of mercuric iodide detector arrays for gamma-ray imaging, making real the possibility of constructing high-performance small, light-weight, portable gamma-ray imaging systems. New techniques have been applied in detector fabrication and then low noise electronics which have produced pixel arrays with high-energy resolution, high spatial resolution, high gamma stopping efficiency. Measurements of the energy resolution capability have been made on a 19-element protypical array. Pixel energy resolutions of 2.98% fwhm and 3.88% fwhm were obtained at 59 keV (241-Am) and 140-keV (99m-Tc), respectively. The pixel spectra for a 14-element section of the data is shown together with the composition of the overlapped individual pixel spectra. These techniques are now being applied to fabricate much larger arrays with thousands of pixels. Extension of these principles to imaging scenarios involving gamma-ray energies up to several hundred keV is also possible. This would enable imaging of the 208 keV and 375-414 keV 239-Pu and 240-Pu structures, as well as the 186 keV line of 235-U.

  12. Advances in data reduction of high-pressure x-ray powder diffraction data from two-dimensional detectors: a case study of schafarzikite (FeSb{sub 2}O{sub 4})

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichsen, B [Max-Planck-Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Dinnebier, R E [Max-Planck-Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Rajiv, P [Max-Planck-Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany); Hanfland, M [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, BP220, 38043 Grenoble Cedex (France); Grzechnik, A [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Technologia, Universidad del Pais Vasco, Apartado 644, E-48080 Bilbao (Spain); Jansen, M [Max-Planck-Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)

    2006-06-28

    Methods have been developed to facilitate the data analysis of multiple two-dimensional powder diffraction images. These include, among others, automatic detection and calibration of Debye-Scherrer ellipses using pattern recognition techniques, and signal filtering employing established statistical procedures like fractile statistics. All algorithms are implemented in the freely available program package Powder3D developed for the evaluation and graphical presentation of large powder diffraction data sets. As a case study, we report the pressure dependence of the crystal structure of iron antimony oxide FeSb{sub 2}O{sub 4} (p{<=}21 GPa, T = 298 K) using high-resolution angle dispersive x-ray powder diffraction. FeSb{sub 2}O{sub 4} shows two phase transitions in the measured pressure range. The crystal structures of all modifications consist of frameworks of Fe{sup 2+}O{sub 6} octahedra and irregular Sb{sup 3+}O{sub 4} polyhedra. At ambient conditions, FeSb{sub 2}O{sub 4} crystallizes in space group P4{sub 2}/mbc (phase I). Between p = 3.2 GPa and 4.1 GPa it exhibits a displacive second order phase transition to a structure of space group P 2{sub 1}/c (phase II, a = 5.7792(4) A, b = 8.3134(9) A, c = 8.4545(11) A, {beta} = 91.879(10){sup 0}, at p = 4.2 GPa). A second phase transition occurs between p = 6.4 GPa and 7.4 GPa to a structure of space group P4{sub 2}/m (phase III, a = 7.8498(4) A, c = 5.7452(5) A, at p = 10.5 GPa). A nonlinear compression behaviour over the entire pressure range is observed, which can be described by three Vinet equations in the ranges from p = 0.52 GPa to p 3.12 GPa, p = 4.2 GPa to p = 6.3 GPa and from p = 7.5 GPa to p = 19.8 GPa. The extrapolated bulk moduli of the high-pressure phases were determined to K{sub 0} = 49(2) GPa for phase I, K{sub 0} = 27(3) GPa for phase II and K{sub 0} = 45(2) GPa for phase III. The crystal structures of all phases are refined against x-ray powder data measured at several pressures between p = 0.52 GPa

  13. Advances in data reduction of high-pressure x-ray powder diffraction data from two-dimensional detectors: a case study of schafarzikite (FeSb(2)O(4)).

    Science.gov (United States)

    Hinrichsen, B; Dinnebier, R E; Rajiv, P; Hanfland, M; Grzechnik, A; Jansen, M

    2006-06-28

    Methods have been developed to facilitate the data analysis of multiple two-dimensional powder diffraction images. These include, among others, automatic detection and calibration of Debye-Scherrer ellipses using pattern recognition techniques, and signal filtering employing established statistical procedures like fractile statistics.All algorithms are implemented in the freely available program package Powder3D developed for the evaluation and graphical presentation of large powder diffraction data sets.As a case study, we report the pressure dependence of the crystal structure of iron antimony oxide FeSb(2)O(4) (p≤21 GPa, T = 298 K) using high-resolution angle dispersive x-ray powder diffraction. FeSb(2)O(4) shows two phase transitions in the measured pressure range. The crystal structures of all modifications consist of frameworks of Fe(2+)O(6) octahedra and irregular Sb(3+)O(4) polyhedra. At ambient conditions, FeSb(2)O(4) crystallizes in space group P4(2)/mbc (phase I). Between p = 3.2 GPa and 4.1 GPa it exhibits a displacive second order phase transition to a structure of space group P 2(1)/c (phase II, a = 5.7792(4) Å, b = 8.3134(9) Å, c = 8.4545(11) Å, β = 91.879(10)°, at p = 4.2 GPa). A second phase transition occurs between p = 6.4 GPa and 7.4 GPa to a structure of space group P4(2)/m (phase III, a = 7.8498(4) Å, c = 5.7452(5) Å, at p = 10.5 GPa). A nonlinear compression behaviour over the entire pressure range is observed, which can be described by three Vinet equations in the ranges from p = 0.52 GPa to p = 3.12 GPa, p = 4.2 GPa to p = 6.3 GPa and from p = 7.5 GPa to p = 19.8 GPa. The extrapolated bulk moduli of the high-pressure phases were determined to K(0) = 49(2) GPa for phase I, K(0) = 27(3) GPa for phase II and K(0) = 45(2) GPa for phase III. The crystal structures of all phases are refined against x-ray powder data measured at several pressures between p = 0.52 GPa, and 10.5 GPa.

  14. Quantum computation with two-dimensional graphene quantum dots

    Institute of Scientific and Technical Information of China (English)

    Li Jie-Sen; Li Zhi-Bing; Yao Dao-Xin

    2012-01-01

    We study an array of graphene nano sheets that form a two-dimensional S =1/2 Kagome spin lattice used for quantum computation.The edge states of the graphene nano sheets axe used to form quantum dots to confine electrons and perform the computation.We propose two schemes of bang-bang control to combat decoherence and realize gate operations on this array of quantum dots.It is shown that both schemes contain a great amount of information for quantum computation.The corresponding gate operations are also proposed.

  15. Uniform non-stoichiometric titanium nitride thin films for improved kinetic inductance detector array

    CERN Document Server

    Coiffard, G; Driessen, E F C; Pignard, S; Calvo, M; Catalano, A; Goupy, J; Monfardini, A

    2015-01-01

    We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz band, comparable to the best aluminium mKIDs. We measured a noise equivalent power of NEP = 3.6e-15 Hz/Hz^(1/2). Finally, we describe possible routes to further improve the performance of these TiN mKID arrays.

  16. Microelectrode arrays with overlapped diffusion layers as electroanalytical detectors: theory and basic applications.

    Science.gov (United States)

    Tomčík, Peter

    2013-10-11

    This contribution contains a survey of basic literature dealing with arrays of microelectrodes with overlapping diffusion layers as prospective tools in contemporary electrochemistry. Photolithographic thin layer technology allows the fabrication of sensors of micrometric dimensions separated with a very small gap. This fact allows the diffusion layers of single microelectrodes to overlap as members of the array. Various basic types of microelectrode arrays with interacting diffusion layers are described and their analytical abilities are accented. Theoretical approaches to diffusion layer overlapping and the consequences of close constitution effects such as collection efficiency and redox cycling are discussed. Examples of basis applications in electroanalytical chemistry such as amperometric detectors in HPLC and substitutional stripping voltammetry are also given.

  17. Microelectrode Arrays with Overlapped Diffusion Layers as Electroanalytical Detectors: Theory and Basic Applications

    Directory of Open Access Journals (Sweden)

    Peter Tomčík

    2013-10-01

    Full Text Available This contribution contains a survey of basic literature dealing with arrays of microelectrodes with overlapping diffusion layers as prospective tools in contemporary electrochemistry. Photolithographic thin layer technology allows the fabrication of sensors of micrometric dimensions separated with a very small gap. This fact allows the diffusion layers of single microelectrodes to overlap as members of the array. Various basic types of microelectrode arrays with interacting diffusion layers are described and their analytical abilities are accented. Theoretical approaches to diffusion layer overlapping and the consequences of close constitution effects such as collection efficiency and redox cycling are discussed. Examples of basis applications in electroanalytical chemistry such as amperometric detectors in HPLC and substitutional stripping voltammetry are also given.

  18. HgCdTe Infrared Avalanche Photodiode Single Photon Detector Arrays for the LIST and Other Decadal Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop a HgCdTe avalanche photodiode (APD)  SWIR/IR linear mode photon counting (LMPC) array detector system in support of the LIST lidar. Provide a new type...

  19. Using a two dimensional array of cameras for daily quality control of ALE following different protocols; Uso de una matriz bidimensional de camaras para el control de calidad diario de un ALE siguiendo diferentes protocolos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Caballero, L. J.; Angulo Pain, E.; Urena Llinares, A.; Iborra Oquendo, M.; Quinones Rodriguez, I.; Castro Ramirez, I.

    2011-07-01

    During the first months of operation of a new electron linear accelerator, beginning the quality assurance program, there is a need to establish an initial record of equipment that can be done in different ways, depending on the existing measuring equipment for each service . The availability of compact arrays formed by ionization chambers like the one we used, permite facilitate this work and also verifying the consistency of other parameters that are usually checked with a higher temporal spacing.

  20. NORSAR Final Scientific Report Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, S J; Ringdal, F; Harris, D B

    2009-04-16

    Correlation detection is a relatively new approach in seismology that offers significant advantages in increased sensitivity and event screening over standard energy detection algorithms. The basic concept is that a representative event waveform is used as a template (i.e. matched filter) that is correlated against a continuous, possibly multichannel, data stream to detect new occurrences of that same signal. These algorithms are therefore effective at detecting repeating events, such as explosions and aftershocks at a specific location. This final report summarizes the results of a three-year cooperative project undertaken by NORSAR and Lawrence Livermore National Laboratory. The overall objective has been to develop and test a new advanced, automatic approach to seismic detection using waveform correlation. The principal goal is to develop an adaptive processing algorithm. By this we mean that the detector is initiated using a basic set of reference ('master') events to be used in the correlation process, and then an automatic algorithm is applied successively to provide improved performance by extending the set of master events selectively and strategically. These additional master events are generated by an independent, conventional detection system. A periodic analyst review will then be applied to verify the performance and, if necessary, adjust and consolidate the master event set. A primary focus of this project has been the application of waveform correlation techniques to seismic arrays. The basic procedure is to perform correlation on the individual channels, and then stack the correlation traces using zero-delay beam forming. Array methods such as frequency-wavenumber analysis can be applied to this set of correlation traces to help guarantee the validity of detections and lower the detection threshold. In principle, the deployment of correlation detectors against seismically active regions could involve very large numbers of very specific

  1. A high resolution germanium detector array for hypernuclear studies at PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Bleser, Sebastian; Sanchez Lorente, Alicia; Steinen, Marcell [Helmholtz-Institut Mainz (Germany); Gerl, Juergen; Kojouharova, Jasmina; Kojouharov, Ivan [GSI Darmstadt (Germany); Iazzi, Felice [Politecnico, Torino (Italy); INFN, Torino (Italy); Pochodzalla, Josef; Rittgen, Kai; Sahin, Cihan [Institute for Nuclear Physics, JGU Mainz (Germany)

    2014-07-01

    The PANDA experiment, planned at the FAIR facility in Darmstadt, aims at the high resolution γ-spectroscopy of double Λ hypernuclei. For this purpose a devoted detector setup is required, consisting of a primary nuclear target, an active secondary target and a germanium detector array for the γ-spectroscopy. Due to the limited space within the PANDA detector a compact design is required. In particular the conventional LN{sub 2} cooling system must be replaced by an electro mechanical device and a new arrangement of the crystals is needed. This presentation shows the progress in the development of the germanium detectors. First results of in-beam measurements at COSY with a new electro mechanically cooled single crystal prototype are presented. Digital pulse shape analysis is used to disentangle pile up events due to the high event rate. This analysis technique also allows to recover the high original energy resolution in case of neutron damage. Finally the status of the new triple crystal detector prototype is given.

  2. Reconstructing primary entrance dose distribution based on transmission dose distribution measured by two-dimensional array%基于二维矩阵透射剂量重建入射原射线注量分布

    Institute of Scientific and Technical Information of China (English)

    王秀楠; 李明辉; 胡逸民

    2016-01-01

    目的:通过电子射野影像装置(Electronic Portal Imaging Device,EPID)平面处测量得到的透射剂量分布重建到模体表面前的原射线注量分布.方法:使用SUN NUCLEAR公司的二维半导体阵列(Mapheck2)和PTW公司的OCTA-VIUS Detector1000SRS测量有模体和无模体时不同大小射野在EPID平面处的透射剂量,通过笔者编写的算法重建入射原射线注量分布,并与三维水箱探头加带平衡帽测量的原射线注量分布比较.结果:采用Gamma法(3 mm/3%)进行评估,在射野内Mapcheck2和OCTAVIUS Detector 1000sRs探测器通过率为100%.结论:本次研究建立的模型得出的原射线离轴比的准确性可满足临床要求,可以用于剂量验证.

  3. High density processing electronics for superconducting tunnel junction x-ray detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Warburton, W.K., E-mail: bill@xia.com [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Harris, J.T. [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Friedrich, S. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2015-06-01

    Superconducting tunnel junctions (STJs) are excellent soft x-ray (100–2000 eV) detectors, particularly for synchrotron applications, because of their ability to obtain energy resolutions below 10 eV at count rates approaching 10 kcps. In order to achieve useful solid detection angles with these very small detectors, they are typically deployed in large arrays – currently with 100+ elements, but with 1000 elements being contemplated. In this paper we review a 5-year effort to develop compact, computer controlled low-noise processing electronics for STJ detector arrays, focusing on the major issues encountered and our solutions to them. Of particular interest are our preamplifier design, which can set the STJ operating points under computer control and achieve 2.7 eV energy resolution; our low noise power supply, which produces only 2 nV/√Hz noise at the preamplifier's critical cascode node; our digital processing card that digitizes and digitally processes 32 channels; and an STJ I–V curve scanning algorithm that computes noise as a function of offset voltage, allowing an optimum operating point to be easily selected. With 32 preamplifiers laid out on a custom 3U EuroCard, and the 32 channel digital card in a 3U PXI card format, electronics for a 128 channel array occupy only two small chassis, each the size of a National Instruments 5-slot PXI crate, and allow full array control with simple extensions of existing beam line data collection packages.

  4. Determination of the experimental setup suitable for the evaluation of two-dimensional distributions of doses using the Map check; Determinacion del montaje experimental idoneo para la evaluacion de distribuciones bidimensionales de dosis empleando el Mapcheck

    Energy Technology Data Exchange (ETDEWEB)

    Chinillach Ferrando, N.; Tortosa Oliver, R. A.; Lorente Franco, L.; Morales Marco, J. C.; Solar Catalan, P.; Andreu Martinez, F. J.

    2013-07-01

    During the process of commissioned and implementation of IMRT module we ask which would be the experimental set-up for the evaluation of the two-dimensional dose distributions using an array of detectors, taking into account the different possibilities offered by the materials available in the service, which allow as to provide three different configurations. The objective of the study is to determine which of the three offered us better results for checks of the two-dimensional distributions of dose in IMRT treatments, taking into account the workload involved in each method. (Author)

  5. Scintillating fiber detectors for the HypHI project at GSI

    NARCIS (Netherlands)

    Nakajima, D.; Oezel-Tashenov, B.; Bianchin, S.; Borodina, O.; Bozkurt, V.; Gokuzum, B.; Kavatsyuk, M.; Minami, S.; Rappold, C.; Saito, T. R.; Achenbach, P.; Ajimura, S.; Ayerbe, C.; Fukuda, T.; Hayashi, Y.; Hiraiwa, T.; Hoffmann, J.; Koch, K.; Kurz, N.; Lepyoshkina, O.; Maas, F.; Mizoi, Y.; Mochizuki, T.; Moritsu, M.; Nagae, T.; Nungesser, L.; Okamura, A.; Ott, W.; Pochodzalla, J.; Sakaguchi, A.; Sako, M.; Schmidt, C. J.; Sugimura, H.; Tanida, K.; Traeger, M.; Trautmann, W.; Voltz, S.

    2009-01-01

    The construction and properties of three sets of two-dimensional scintillating fiber detector arrays for tracking of charged particles used in the HypHI Phase 0 experiment at GSI will be reported in this paper. The position resolutions and the detection efficiency of detectors have been obtained for

  6. Scintillating fiber detectors for the HypHI project at GSI

    NARCIS (Netherlands)

    Nakajima, D.; Oezel-Tashenov, B.; Bianchin, S.; Borodina, O.; Bozkurt, V.; Gokuzum, B.; Kavatsyuk, M.; Minami, S.; Rappold, C.; Saito, T. R.; Achenbach, P.; Ajimura, S.; Ayerbe, C.; Fukuda, T.; Hayashi, Y.; Hiraiwa, T.; Hoffmann, J.; Koch, K.; Kurz, N.; Lepyoshkina, O.; Maas, F.; Mizoi, Y.; Mochizuki, T.; Moritsu, M.; Nagae, T.; Nungesser, L.; Okamura, A.; Ott, W.; Pochodzalla, J.; Sakaguchi, A.; Sako, M.; Schmidt, C. J.; Sugimura, H.; Tanida, K.; Traeger, M.; Trautmann, W.; Voltz, S.

    2009-01-01

    The construction and properties of three sets of two-dimensional scintillating fiber detector arrays for tracking of charged particles used in the HypHI Phase 0 experiment at GSI will be reported in this paper. The position resolutions and the detection efficiency of detectors have been obtained for

  7. Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging.

    Science.gov (United States)

    Iwanczyk, Jan S; Nygård, Einar; Meirav, Oded; Arenson, Jerry; Barber, William C; Hartsough, Neal E; Malakhov, Nail; Wessel, Jan C

    2009-01-01

    The development of an innovative detector technology for photon-counting in X-ray imaging is reported. This new generation of detectors, based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CZT) detector arrays electrically connected to application specific integrated circuits (ASICs) for readout, will produce fast and highly efficient photon-counting and energy-dispersive X-ray imaging. There are a number of applications that can greatly benefit from these novel imagers including mammography, planar radiography, and computed tomography (CT). Systems based on this new detector technology can provide compositional analysis of tissue through spectroscopic X-ray imaging, significantly improve overall image quality, and may significantly reduce X-ray dose to the patient. A very high X-ray flux is utilized in many of these applications. For example, CT scanners can produce ~100 Mphotons/mm(2)/s in the unattenuated beam. High flux is required in order to collect sufficient photon statistics in the measurement of the transmitted flux (attenuated beam) during the very short time frame of a CT scan. This high count rate combined with a need for high detection efficiency requires the development of detector structures that can provide a response signal much faster than the transit time of carriers over the whole detector thickness. We have developed CdTe and CZT detector array structures which are 3 mm thick with 16×16 pixels and a 1 mm pixel pitch. These structures, in the two different implementations presented here, utilize either a small pixel effect or a drift phenomenon. An energy resolution of 4.75% at 122 keV has been obtained with a 30 ns peaking time using discrete electronics and a (57)Co source. An output rate of 6×10(6) counts per second per individual pixel has been obtained with our ASIC readout electronics and a clinical CT X-ray tube. Additionally, the first clinical CT images, taken with several of our prototype photon-counting and

  8. Speciation of manganese binding to biomolecules in pine nuts (Pinus pinea) by two-dimensional liquid chromatography coupled to ultraviolet and inductively coupled plasma mass spectrometry detectors followed by identification by electrospray ionization mass spectrometry.

    Science.gov (United States)

    Arias-Borrego, Ana; García-Barrera, Tamara; Gómez-Ariza, José L

    2008-10-01

    Advances in analytical methodology for speciation of manganese in pine nuts are presented in this work. The approach is based on the use of orthogonal chromatographic systems, namely size-exclusion chromatography (SEC) of the extracts and strong anion exchange (IEC) of the fractions collected by the first column. In both columns, manganese elution is first monitored by a quadrupole inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with an octopole reaction cell and an ultraviolet (UV) detector. SEC is performed by using two columns covering the molecular weight range from pine nuts samples and the presence of Mn-citrate is confirmed by nanoelectrospray ionization quadrupole time-of-flight mass spectrometry (nESI-QqTOF-MS). In the same fraction, a third Mn-containing peak is detected in the IEC-UV-ICP-MS chromatogram. This peak corresponds to a protein containing Mn that was later submitted to a tryptic digestion and analyzed by nESI-QqTOF. The MS/MS data of a doubly charged peptide are used to obtain the sequence of the protein with the Mascot search engine. The peak turned out to be isocitrate dehydrogenase, a protein commonly associated with Mn.

  9. Two Dimensional Plasmonic Cavities on Moire Surfaces

    Science.gov (United States)

    Balci, Sinan; Kocabas, Askin; Karabiyik, Mustafa; Kocabas, Coskun; Aydinli, Atilla

    2010-03-01

    We investigate surface plasmon polariton (SPP) cavitiy modes on two dimensional Moire surfaces in the visible spectrum. Two dimensional hexagonal Moire surface can be recorded on a photoresist layer using Interference lithography (IL). Two sequential exposures at slightly different angles in IL generate one dimensional Moire surfaces. Further sequential exposure for the same sample at slightly different angles after turning the sample 60 degrees around its own axis generates two dimensional hexagonal Moire cavity. Spectroscopic reflection measurements have shown plasmonic band gaps and cavity states at all the azimuthal angles (omnidirectional cavity and band gap formation) investigated. The plasmonic band gap edge and the cavity states energies show six fold symmetry on the two dimensional Moire surface as measured in reflection measurements.

  10. Two-dimensional function photonic crystals

    Science.gov (United States)

    Liu, Xiao-Jing; Liang, Yu; Ma, Ji; Zhang, Si-Qi; Li, Hong; Wu, Xiang-Yao; Wu, Yi-Heng

    2017-01-01

    In this paper, we have studied two-dimensional function photonic crystals, in which the dielectric constants of medium columns are the functions of space coordinates , that can become true easily by electro-optical effect and optical kerr effect. We calculated the band gap structures of TE and TM waves, and found the TE (TM) wave band gaps of function photonic crystals are wider (narrower) than the conventional photonic crystals. For the two-dimensional function photonic crystals, when the dielectric constant functions change, the band gaps numbers, width and position should be changed, and the band gap structures of two-dimensional function photonic crystals can be adjusted flexibly, the needed band gap structures can be designed by the two-dimensional function photonic crystals, and it can be of help to design optical devices.

  11. Two-Dimensional Planetary Surface Lander

    Science.gov (United States)

    Hemmati, H.; Sengupta, A.; Castillo, J.; McElrath, T.; Roberts, T.; Willis, P.

    2014-06-01

    A systems engineering study was conducted to leverage a new two-dimensional (2D) lander concept with a low per unit cost to enable scientific study at multiple locations with a single entry system as the delivery vehicle.

  12. Current status of the new LaBr{sub 3}:Ce detector array GALATEA

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Christopher; Neumann-Cosel, Peter von; Ries, Philipp; Pietralla, Norbert; Scheit, Heiko; Schnorrenberger, Linda [Technische Univ. Darmstadt (Germany). Inst. fuer Kernphysik; Lefol, Ronan [University of Saskatchewan (Canada)

    2013-07-01

    In contrast to common scintillation materials like NaI and BaF{sub 2} the recently developed LaBr{sub 3}:Ce detectors allow measurements with excellent time resolution and high efficiency while retaining a good energy resolution. To perform successful (e,e{sup '}γ) and (γ,γ{sup '}γ) coincidence experiments at the linear electron accelerator S-DALINAC all three features are of utmost importance. We present the current status of the new LaBr{sub 3}:Ce detector array GALATEA (GAmma LAnthanum bromide Top Efficiency Array) consisting of 18 large 3'' x 3'' LaBr{sub 3}:Ce detectors. One focus is on the completely digital DAQ based on flash ADCs and newly developed pulse shape analysis methods for timing and particle identification. The performance of GALATEA is discussed regarding energy resolution, time resolution, linearity and efficiency. The results are compared to GEANT4 simulations.

  13. Dark Current Characteristics of a Radiation Detector Array Developed Using MOVPE-Grown Thick CdTe Layers on Si Substrate

    Science.gov (United States)

    Yasuda, K.; Niraula, M.; Fujimura, N.; Tachi, T.; Inuzuka, H.; Namba, S.; Muramatsu, S.; Kondo, T.; Agata, Y.

    2012-10-01

    We present reverse bias current (dark current) characteristics of a two-dimensional monolithic pixel-type nuclear radiation detector array fabricated using metalorganic vapor-phase epitaxy (MOVPE)-grown thick CdTe epitaxial layers on Si substrate. The (14 × 8) pixel array was formed by cutting deep vertical trenches using a dicing saw, where each pixel possesses a p-CdTe/ n-CdTe/ n +-Si heterojunction diode structure. The dark currents showed pixel-to-pixel variations when measured at higher applied biases exceeding 100 V. The dark current had a dependence on the pixel thickness, where pixels with lower CdTe thickness exhibited higher currents. Moreover, the temperature dependence of the dark current revealed that a deep level with activation energy of around 0.6 eV is responsible for the observed dark currents and their pixel-to-pixel variation. We discuss that the effective ratio of Te to Cd at the growth surface is a major factor that controls the thickness variation, and is also responsible for the formation of 0.6 eV deep levels.

  14. Leaky Lens Based UWB Focal Plane Arrays for Sub-mm Wave Imaging Based on Kinetic Inductance Detectors

    NARCIS (Netherlands)

    Neto, A.

    2008-01-01

    A novel strategy for broad band focal plane array design is proposed. Its purpose is to couple the radiation from a Large FID reflector system to an array of Kinetic Inductance detectors that are being investigated and realized at SRON. To maximize the benefits from using their BW properties the ide

  15. Digital data acquisition for the Low Energy Neutron Detector Array (LENDA)

    Energy Technology Data Exchange (ETDEWEB)

    Lipschutz, S., E-mail: lipschutz@nscl.msu.edu [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Zegers, R.G.T.; Hill, J. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Liddick, S.N. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI (United States); Noji, S., E-mail: noji@rcnp.osaka-u.ac.jp [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Prokop, C.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI (United States); Scott, M. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Solt, M., E-mail: mrsolt@stanford.edu [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Department of Physics, Oakland University, Rochester, MI (United States); and others

    2016-04-11

    A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV–10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibility to lower the neutron detection threshold, increase the overall neutron-detection efficiency, decrease the dead time of the system, and allow for easy expansion of the array. The system utilized in this work was XIA's Digital Gamma Finder Pixie-16 250 MHz digitizers. A detector-limited timing resolution of 400 ps was achieved for a single LENDA bar. Using DDAS, the neutron detection threshold of the system was reduced compared to the previous analog system, now reaching below 100 keV. The new DAQ system was successfully used in a recent charge-exchange experiment using the {sup 16}C(p,n) reaction at the National Superconducting Cyclotron Laboratory (NSCL).

  16. Fast IR Array Detector for Transverse Beam Diagnostics at DA{\\Phi}NE

    CERN Document Server

    Bocci, A; Clozza, A; Drago, A; Grilli, A; Marcelli, A; Raco, A; Sorchetti, R; Gambicorti, L; De Sio, A; Pace, E; Piotrowski, J

    2010-01-01

    At the Laboratori Nazionali di Frascati of the National Institute of Nuclear Physics (INFN) an infrared (IR) array detector with fast response time has been built and assembled in order to collect the IR image of e-/e+ sources of the DA{\\Phi}NE collider. Such detector is made by 32 bilinear pixels with an individual size of 50x50 {\\mu}m2 and a response time of ~1 ns. In the framework of an experiment funded by the INFN Vth Committee dedicated to beam diagnostics, the device with its electronic board has been tested and installed on the DA{\\Phi}NE positron ring. A preliminary characterization of few pixels of the array and of the electronics has been carried out at the IR beamline SINBAD at DA{\\Phi}NE. In particular the detection of the IR source of the e- beam has been observed using four pixels of the array acquiring signals simultaneously with a four channels scope at 1 GHz and at 10 Gsamples/s. The acquisition of four pixels allowed monitoring in real time differences in the bunch signals in the vertical d...

  17. Digital Data Acquisition For the Low Energy Neutron Detector Array (LENDA)

    CERN Document Server

    Lipschutz, S; Hill, J; Liddick, S N; Noji, S; Prokop, C J; Scott, M; Solt, M; Sullivan, C; Tompkins, J

    2016-01-01

    A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV to 10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibility to lower the neutron detection threshold, increase the overall neutron-detection efficiency, decrease the dead time of the system, and allow for easy expansion of the array. The system utilized in this work was XIA's Digital Gamma Finder Pixie-16 250 MHz digitizers. A detector-limited timing resolution of 400 ps was achieved for a single LENDA bar. Using DDAS, the neutron detection threshold of the system was reduced compared to the previous analog system, now reaching below 100 keV. The new DAQ system was successfully used in a recent charge-exchange experiment using the $^{16}$C(p,n) reaction at the National Sup...

  18. Analysis of lichen substances including triterpenoids by high performance liquid chromatography with a differential refractive index detector and a photodiode array detector

    Institute of Scientific and Technical Information of China (English)

    Hikari SATO; Kojiro HARA; Masashi KOMINE; Yoshikazu YAMAMOTO

    2011-01-01

    A new method for analysis of lichen triterpenoids was established using high performance liquid chromatography with the combination of a differential refractive index detector (RID) and a photodiode array detector (PDA).It is proved that this method was convenient to detect and identify aromatic and aliphatic lichen substances; it enabled quantitative analysis of substances having no or less absorption of ultraviolet rays such as triterpenoids.In addition,they can be measured in high accuracy compared with the TLC method.

  19. Stress Wave Propagation in Two-dimensional Buckyball Lattice

    Science.gov (United States)

    Xu, Jun; Zheng, Bowen

    2016-11-01

    Orderly arrayed granular crystals exhibit extraordinary capability to tune stress wave propagation. Granular system of higher dimension renders many more stress wave patterns, showing its great potential for physical and engineering applications. At nanoscale, one-dimensionally arranged buckyball (C60) system has shown the ability to support solitary wave. In this paper, stress wave behaviors of two-dimensional buckyball (C60) lattice are investigated based on square close packing and hexagonal close packing. We show that the square close packed system supports highly directional Nesterenko solitary waves along initially excited chains and hexagonal close packed system tends to distribute the impulse and dissipates impact exponentially. Results of numerical calculations based on a two-dimensional nonlinear spring model are in a good agreement with the results of molecular dynamics simulations. This work enhances the understanding of wave properties and allows manipulations of nanoscale lattice and novel design of shock mitigation and nanoscale energy harvesting devices.

  20. Tiled Array of Pixelated CZT Imaging Detectors for ProtoEXIST2 and MIRAX-HXI

    CERN Document Server

    Hong, Jaesub; Grindlay, Jonathan; Rodrigues, Barbara; Ellis, Jon Robert; Baker, Robert; Barthelmy, Scott; Mao, Peter; Miyasaka, Hiromasa; Apple, Jeff

    2013-01-01

    We have assembled a tiled array (220 cm2) of fine pixel (0.6 mm) imaging CZT detectors for a balloon borne wide-field hard X-ray telescope, ProtoEXIST2. ProtoEXIST2 is a prototype experiment for a next generation hard X-ray imager MIRAX-HXI on board Lattes, a spacecraft from the Agencia Espacial Brasilieira. MIRAX will survey the 5 to 200 keV sky of Galactic bulge, adjoining southern Galactic plane and the extragalactic sky with 6' angular resolution. This survey will open a vast discovery space in timing studies of accretion neutron stars and black holes. The ProtoEXIST2 CZT detector plane consists of 64 of 5 mm thick 2 cm x 2 cm CZT crystals tiled with a minimal gap. MIRAX will consist of 4 such detector planes, each of which will be imaged with its own coded-aperture mask. We present the packaging architecture and assembly procedure of the ProtoEXIST2 detector. On 2012, Oct 10, we conducted a successful high altitude balloon experiment of the ProtoEXIST1 and 2 telescopes, which demonstrates their technolog...

  1. Trigger electronics of the new Fluorescence Detectors of the Telescope Array Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Tameda, Yuichiro [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan)], E-mail: tame@cr.phys.titech.ac.jp; Taketa, Akimichi [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Smith, Jeremy D. [Institute for High Energy Astrophysics and Department of Physics, University of Utah, Salt Lake City, UT 84112-0830 (United States); Tanaka, Manobu [Institute of Particle and Nuclear Studies, KEK, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Fukushima, Masaki [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Jui, Charles C.H. [Institute for High Energy Astrophysics and Department of Physics, University of Utah, Salt Lake City, UT 84112-0830 (United States); Kadota, Ken' ichi [Faculty of Knowledge Engineering, Musashi Institute of Technology, Setagaya, Tokyo 158-8557 (Japan); Kakimoto, Fumio [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Matsuda, Takeshi [Institute of Particle and Nuclear Studies, KEK, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Matthews, John N. [Institute for High Energy Astrophysics and Department of Physics, University of Utah, Salt Lake City, UT 84112-0830 (United States); Ogio, Shoichi [Graduate School of Science, Osaka City University, Sumiyoshi, Osaka 558-8585 (Japan); Sagawa, Hiroyuki; Sakurai, Nobuyuki; Shibata, Tatsunobu; Takeda, Masahiro [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Thomas, Stanton B. [Institute for High Energy Astrophysics and Department of Physics, University of Utah, Salt Lake City, UT 84112-0830 (United States); Tokuno, Hisao [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Tsunesada, Yoshiki [Graduate School of Science and Engineering, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan)] (and others)

    2009-10-11

    The Telescope Array Project is an experiment designed to observe Ultra High Energy Cosmic Rays via a 'hybrid' detection technique utilizing both fluorescence light detectors (FDs) and scintillator surface particle detectors (SDs). We have installed three FD stations and 507 SDs in the Utah desert, and initiated observations from March 2008. The northern FD station reuses 14 telescopes from the High Resolution Fly's Eye, HiRes-I station. Each of the two southern FD stations contains 12 new telescopes utilizing new FADC electronics. Each telescope is instrumented with a camera composed of 256 PMTs. Since the detectors are composed of many PMTs and each PMT detects fluorescence photons together with the vast amount of night sky background, a sophisticated triggering system is required. In this paper, we describe the trigger electronics of these new FD stations. We also discuss performance of the FDs with this triggering system, in terms of efficiencies and apertures for various detector configurations.

  2. Low noise CMOS readout for CdZnTe detector arrays

    CERN Document Server

    Jakobson, C G; Lev, S B; Nemirovsky, Y

    1999-01-01

    A low noise CMOS readout for CdTe and CdZnTe X- and gamma-ray detector arrays has been designed and implemented in the CMOS 2 mu m low noise analog process provided by the multi-chip program of Metal Oxide Semiconductor Implementation Service. The readout includes CMOS low noise charge sensitive preamplifier and a multiplexed semi-Gaussian pulse shaper. Thus, each detector has a dedicated charge sensitive preamplifier that integrates its signal, while a single shaping amplifier shapes the pulses after the multiplexer. Low noise and low-power operation are achieved by optimizing the input transistor of the charge sensitive preamplifier. Two optimization criteria are used to reduce noise. The first criterion is based on capacitance matching between the input transistor and the detector. The second criterion is based on bandwidth optimization, which is obtained by tailoring the shaper parameters to the particular noise mechanisms of the MOS transistor and the CdZnTe detector. Furthermore, the multiplexing functi...

  3. Low noise CMOS readout for CdZnTe detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Jakobson, C.G.; Asa, G.; Lev, S. Bar; Nemirovsky, Y. E-mail: nemirov@ee.technion.ac.il

    1999-06-01

    A low noise CMOS readout for CdTe and CdZnTe X- and gamma-ray detector arrays has been designed and implemented in the CMOS 2 {mu}m low noise analog process provided by the multi-chip program of Metal Oxide Semiconductor Implementation Service. The readout includes CMOS low noise charge sensitive preamplifier and a multiplexed semi-Gaussian pulse shaper. Thus, each detector has a dedicated charge sensitive preamplifier that integrates its signal, while a single shaping amplifier shapes the pulses after the multiplexer. Low noise and low-power operation are achieved by optimizing the input transistor of the charge sensitive preamplifier. Two optimization criteria are used to reduce noise. The first criterion is based on capacitance matching between the input transistor and the detector. The second criterion is based on bandwidth optimization, which is obtained by tailoring the shaper parameters to the particular noise mechanisms of the MOS transistor and the CdZnTe detector. Furthermore, the multiplexing function incorporated in the shaper provides low power and reduces chip area. The system is partitioned into a chip containing the charge amplifiers and a chip containing the semi-Gaussian pulse shaper and multiplexer. This architecture minimizes coupling from multiplexer switches as well as shaper output to the input of the charge sensitive preamplifiers.

  4. InGaAs Schottky barrier diode array detector for a real-time compact terahertz line scanner.

    Science.gov (United States)

    Han, Sang-Pil; Ko, Hyunsung; Park, Jeong-Woo; Kim, Namje; Yoon, Young-Jong; Shin, Jun-Hwan; Kim, Dae Yong; Lee, Dong Hun; Park, Kyung Hyun

    2013-11-04

    We present a terahertz (THz) broadband antenna-integrated 1 × 20 InGaAs Schottky barrier diode (SBD) array detector with an average responsivity of 98.5 V/W at a frequency of 250 GHz, which is measured without attaching external amplifiers and Si lenses, and an average noise equivalent power (NEP) of 106.6 pW/√Hz. The 3-dB bandwidth of the SBD detector is also investigated at approximately 180 GHz. For implementing an array-type SBD detector by a simple fabrication process to achieve a high yield, a structure comprising an SiN(x) layer instead of an air bridge between the anode and the cathode is designed. THz line beam imaging using a Gunn diode emitter with a center frequency of 250 GHz and a 1 × 20 SBD array detector is successfully demonstrated.

  5. The Cosmic Ray Energy Spectrum Observed with the Surface Detector of the Telescope Array Experiment

    CERN Document Server

    Abu-Zayyad, T; Allen, M; Anderson, R; Azuma, R; Barcikowski, E; Belz, J W; Bergman, D R; Blake, S A; Cady, R; Cheon, B G; Chiba, J; Chikawa, M; Cho, E J; Cho, W R; Fujii, H; Fujii, T; Fukuda, T; Fukushima, M; Hanlon, W; Hayashi, K; Hayashi, Y; Hayashida, N; Hibino, K; Hiyama, K; Honda, K; Iguchi, T; Ikeda, D; Ikuta, K; Inoue, N; Ishii, T; Ishimori, R; Ivanov, D; Iwamoto, S; Jui, C C H; Kadota, K; Kakimoto, F; Kalashev, O; Kanbe, T; Kasahara, K; Kawai, H; Kawakami, S; Kawana, S; Kido, E; Kim, H B; Kim, H K; Kim, J H; Kim, J H; Kitamoto, K; Kitamura, S; Kitamura, Y; Kobayashi, K; Kobayashi, Y; Kondo, Y; Kuramoto, K; Kuzmin, V; Kwon, Y J; Lim, S I; Machida, S; Martens, K; Martineau, J; Matsuda, T; Matsuura, T; Matsuyama, T; Matthews, J N; Minamino, M; Miyata, K; Murano, Y; Myers, I; Nagasawa, K; Nagataki, S; Nakamura, T; Nam, S W; Nonaka, T; Ogio, S; Ohnishi, M; Ohoka, H; Oki, K; Oku, D; Okuda, T; Oshima, A; Ozawa, S; Park, I H; Pshirkov, M S; Rodriguez, D C; Roh, S Y; Rubtsov, G; Ryu, D; Sagawa, H; Sakurai, N; Sampson, A L; Scott, L M; Shah, P D; Shibata, F; Shibata, T; Shimodaira, H; Shin, B K; Shin, J I; Shirahama, T; Smith, J D; Sokolsky, P; Sonley, T J; Springer, R W; Stokes, B T; Stratton, S R; Stroman, T; Suzuki, S; Takahashi, Y; Takeda, M; Taketa, A; Takita, M; Tameda, Y; Tanaka, H; Tanaka, K; Tanaka, M; Thomas, S B; Thomson, G B; Tinyakov, P; Tkachev, I; Tokuno, H; Tomida, T; Troitsky, S; Tsunesada, Y; Tsutsumi, K; Tsuyuguchi, Y; Uchihori, Y; Udo, S; Ukai, H; Vasiloff, G; Wada, Y; Wong, T; Wood, M; Yamakawa, Y; Yamane, R; Yamaoka, H; Yamazaki, K; Yang, J; Yoneda, Y; Yoshida, S; Yoshii, H; Zhou, X; Zollinger, R R; Zundel, Z

    2012-01-01

    The Telescope Array (TA) collaboration has measured the energy spectrum of ultra-high energy cosmic rays for energies above 1.6x10^(18) eV in its first three years of operation. The spectrum shows a dip at an energy of 5x10^(18) eV and a steepening at 5x10^(19) eV which is consistent with the expectation from the GZK cutoff. Here we use a new technique that involves generating a complete simulation of the TA surface detector. The procedure starts with shower simulations using the CORSIKA Monte Carlo program where we have solved the problems caused by use of the "thinning" approximation. This simulation method allows us to make an accurate calculation of the acceptance of the detector for the energies concerned.

  6. Design and operation of a 2-D thin-film semiconductor neutron detector array for use as a beamport monitor

    Energy Technology Data Exchange (ETDEWEB)

    Unruh, Troy C.; Bellinger, Steven L. [SMART Laboratory, Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States); Huddleston, David E. [Electronics Design Laboratory, Kansas State University, Manhattan, KS 66506 (United States); McNeil, Walter J.; Patterson, Eric [SMART Laboratory, Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States); Sobering, Tim J. [Electronics Design Laboratory, Kansas State University, Manhattan, KS 66506 (United States); McGregor, Douglas S. [SMART Laboratory, Kansas State University, Mechanical and Nuclear Engineering Department, Manhattan, KS 66506 (United States)], E-mail: mcgregor@ksu.edu

    2009-06-01

    Silicon-based diodes coated with a thin film of neutron reactive materials have been shown to produce excellent low-efficiency neutron detectors. This work employs the same technology, but groups 25 equally sized and spaced diodes on a single 29 mm by 29 mm substrate. A 5x5 array was fabricated and coated with a thin film of {sup 6}LiF for use as a low-efficiency neutron beam monitor. The 5x5 neutron detector array is coupled to an array of amplifiers, allowing the response to be interpreted using a LabVIEW FPGA. The 5x5 array has been characterized in a diffracted neutron beam. This work is a part of on-going research to develop various designs of high- and low-efficiency semiconductor neutron detectors.

  7. A Failure Mode in Dense Infrared Detector Arrays Resulting in Increased Dark Current

    Science.gov (United States)

    Pinkie, Benjamin; Bellotti, Enrico

    2016-09-01

    In this paper, we investigate a failure mode that arises in dense infrared focal plane detector arrays as a consequence of the interactions of neighboring pixels through the minority carrier profiles in the common absorber layer. We consider the situation in which one pixel in a hexagonal array becomes de-biased relative to its neighbors and show that the dark current in the six neighboring pixels increases exponentially as a function of the difference between the nominal and anomalous biases. Moreover, we show that the current increase in the six nearest-neighbor pixels is in total larger than that by which the current in the affected pixel decreases, causing a net increase in the dark current. The physical origins of this effect are explained as being due to increased lateral diffusion currents that arise as a consequence of breaking the symmetry of the minority carrier profiles. We then perform a parametric study to quantify the magnitude of this effect for a number of detector geometric parameters, operating temperatures, and spectral bands. Particularly, numerical simulations are carried out for short-, mid-, and long-wavelength HgCdTe infrared detectors operating between 77 K and 210 K. We show that this effect is most prevalent in architectures for which the lateral diffusion current is the largest component of the total dark current—high operating temperature devices with narrow epitaxial absorber thicknesses and pitches small compared to the diffusion length of minority carriers. These results could prove significant particularly for short- and mid-wave infrared detectors, which are typically designed to fit these conditions.

  8. Electrode thickness measurement of a Si(Li) detector for the SIXA array

    OpenAIRE

    Tikkanen, T. (Tiia); Hamalainen, K.; Huotari, S.

    1997-01-01

    Cathode electrodes of the Si(Li) detector elements of the SIXA X-ray spectrometer array are formed by gold-palladium alloy contact layers. The equivalent thickness of gold in one element was measured by observing the characteristic L-shell X-rays of gold excited by monochromatised synchrotron radiation with photon energies above the L3 absorption edge of gold. The results obtained at 4 different photon energies below the L2 edge yield an average value of 22.4(35) nm which is consistent with t...

  9. Observation of high energy atmospheric neutrinos with antarctic muon and neutrino detector array

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, J.; Andres, E.; Bai, X.; Barouch, G.; Barwick, S.W.; Bay, R.C.; Becka, T.; Becker, K.-H.; Bertrand, D.; Binon, F.; Biron, A.; Booth, J.; Botner, O.; Bouchta, A.; Bouhali, O.; Boyce, M.M.; Carius, S.; Chen, A.; Chirkin, D.; Conrad, J.; Cooley, J.; Costa, C.G.S.; Cowen, D.F.; Dalberg, E.; De Clercq, C.; DeYoung, T.; Desiati, P.; Dewulf, J.-P.; Doksus, P.; Edsjo, J.; Ekstrom, P.; Feser, T.; Frere, J.-M.; Gaisser, T.K.; Gaug, M.; Goldschmidt, A.; Hallgren, A.; Halzen, F.; Hanson, K.; Hardtke, R.; Hauschildt, T.; Hellwig, M.; Heukenkamp, H.; Hill, G.C.; Hulth, P.O.; Hundertmark, S.; Jacobsen, J.; Karle, A.; Kim, J.; Koci, B.; Kopke, L.; Kowalski, M.; Lamoureux, J.I.; Leich, H.; Leuthold, M.; Lindahl, P.; Liubarsky, I.; Loaiza, P.; Lowder, D.M.; Madsen, J.; Marciniewski, P.; Matis, H.S.; McParland, C.P.; Miller, T.C.; Minaeva, Y.; Miocinovic, P.; Mock, P.C.; Morse, R.; Neunhoffer, T.; Niessen, P.; Nygren, D.R.; Ogelman, H.; Olbrechts, Ph.; Perez de los Heros, C.; Pohl, A.C.; Porrata, R.; Price, P.B.; Przybylski, G.T.; Rawlins, K.; Reed, C.; Rhode, W.; Ribordy, M.; Richter, S.; Rodriguez Martino, J.; Romenesko, P.; Ross, D.; Sander, H.-G.; Schmidt, T.; Schneider, D.; Schwarz, R.; Silvestri, A.; Solarz, M.; Spiczak, G.M.; Spiering, C.; Starinsky, N.; Steele, D.; Steffen, P.; Stokstad, R.G.; Streicher, O.; Sudhoff, P.; Sulanke, K.-H.; Taboada, I.; Thollander, L.; Thon, T.; Tilav, S.; Vander Donckt, M.; Walck, C.; Weinheimer, C.; Wiebusch, C.H.; Wiedeman, C.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Wu, W.; Yodh, G.; Young, S.

    2002-05-07

    The Antarctic Muon and Neutrino Detector Array (AMANDA) began collecting data with ten strings in 1997. Results from the first year of operation are presented. Neutrinos coming through the Earth from the Northern Hemisphere are identified by secondary muons moving upward through the array. Cosmic rays in the atmosphere generate a background of downward moving muons, which are about 10{sup 6} times more abundant than the upward moving muons. Over 130 days of exposure, we observed a total of about 300 neutrino events. In the same period, a background of 1.05 x 10{sup 9} cosmic ray muon events was recorded. The observed neutrino flux is consistent with atmospheric neutrino predictions. Monte Carlo simulations indicate that 90 percent of these events lie in the energy range 66 GeV to 3.4 TeV. The observation of atmospheric neutrinos consistent with expectations establishes AMANDA-B10 as a working neutrino telescope.

  10. Performance of a compact multi-crystal high-purity germanium detector array for measuring coincident gamma-ray emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris; Daigle, Stephen; Buckner, Matt [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Erikson, Luke E.; Runkle, Robert C. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Stave, Sean C., E-mail: Sean.Stave@pnnl.gov [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Champagne, Arthur E.; Cooper, Andrew; Downen, Lori [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Glasgow, Brian D. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Kelly, Keegan; Sallaska, Anne [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States)

    2015-05-21

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the {sup 14}N(p,γ){sup 15}O{sup ⁎} reaction for several transition energies at an effective center-of-mass energy of 163 keV. Owing to the granular nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within their uncertainties with the past measurements. Details of the analysis and detector performance are presented.

  11. Performance of A Compact Multi-crystal High-purity Germanium Detector Array for Measuring Coincident Gamma-ray Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Daigle, Stephen [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Buckner, Matt [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Erikson, Luke E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Runkle, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stave, Sean C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Champagne, Art [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Cooper, Andrew [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Downen, Lori [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Glasgow, Brian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kelly, Keegan [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Sallaska, Anne [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States)

    2015-02-18

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the 14N(p,γ)15O* reaction for several transition energies at an effective center of mass energy of 163 keV. Owing to the segmented nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within the uncertainties with the past measurements. Details of the analysis and detector performance will be presented.

  12. Graphical user interface for a dual-module EMCCD x-ray detector array

    Science.gov (United States)

    Wang, Weiyuan; Ionita, Ciprian; Kuhls-Gilcrist, Andrew; Huang, Ying; Qu, Bin; Gupta, Sandesh K.; Bednarek, Daniel R.; Rudin, Stephen

    2011-03-01

    A new Graphical User Interface (GUI) was developed using Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) for a high-resolution, high-sensitivity Solid State X-ray Image Intensifier (SSXII), which is a new x-ray detector for radiographic and fluoroscopic imaging, consisting of an array of Electron-Multiplying CCDs (EMCCDs) each having a variable on-chip electron-multiplication gain of up to 2000x to reduce the effect of readout noise. To enlarge the field-of-view (FOV), each EMCCD sensor is coupled to an x-ray phosphor through a fiberoptic taper. Two EMCCD camera modules are used in our prototype to form a computer-controlled array; however, larger arrays are under development. The new GUI provides patient registration, EMCCD module control, image acquisition, and patient image review. Images from the array are stitched into a 2kx1k pixel image that can be acquired and saved at a rate of 17 Hz (faster with pixel binning). When reviewing the patient's data, the operator can select images from the patient's directory tree listed by the GUI and cycle through the images using a slider bar. Commonly used camera parameters including exposure time, trigger mode, and individual EMCCD gain can be easily adjusted using the GUI. The GUI is designed to accommodate expansion of the EMCCD array to even larger FOVs with more modules. The high-resolution, high-sensitivity EMCCD modular-array SSXII imager with the new user-friendly GUI should enable angiographers and interventionalists to visualize smaller vessels and endovascular devices, helping them to make more accurate diagnoses and to perform more precise image-guided interventions.

  13. Interpolation by two-dimensional cubic convolution

    Science.gov (United States)

    Shi, Jiazheng; Reichenbach, Stephen E.

    2003-08-01

    This paper presents results of image interpolation with an improved method for two-dimensional cubic convolution. Convolution with a piecewise cubic is one of the most popular methods for image reconstruction, but the traditional approach uses a separable two-dimensional convolution kernel that is based on a one-dimensional derivation. The traditional, separable method is sub-optimal for the usual case of non-separable images. The improved method in this paper implements the most general non-separable, two-dimensional, piecewise-cubic interpolator with constraints for symmetry, continuity, and smoothness. The improved method of two-dimensional cubic convolution has three parameters that can be tuned to yield maximal fidelity for specific scene ensembles characterized by autocorrelation or power-spectrum. This paper illustrates examples for several scene models (a circular disk of parametric size, a square pulse with parametric rotation, and a Markov random field with parametric spatial detail) and actual images -- presenting the optimal parameters and the resulting fidelity for each model. In these examples, improved two-dimensional cubic convolution is superior to several other popular small-kernel interpolation methods.

  14. Design of a Dry Dilution Refrigerator for MMC Gamma Detector Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Stephan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Boyd, Stephen [Univ. of New Mexico, Albuquerque, NM (United States); Cantor, Robin

    2017-04-03

    The goal of this LCP is to develop an ultra-high resolution gamma detector based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material to replace current Au:Er sensors. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers. MMC detectors require operating temperatures of ~15 mK and thus the use of a dilution refrigerator, and the desire for user-friendly operation without cryogenic liquids requires that this refrigerator use pulse-tube pre-cooling to ~4 K. For long-term reliability, we intend to re-design the heat switch that is needed to apply the magnetizing current to the Ag:Er sensor and that used to fail in earlier designs after months of operation. A cryogenic Compton veto will be installed to reduce the spectral background of the MMC, especially at low energies where ultra-high energy resolution is most important. The goals for FY16 were 1) to purchase a liquid-cryogen-free dilution refrigerator and adapt it for MMC operation, and 2) to fabricate Ag:Er-based MMC γ-detectors with improved performance and optimize their response. This report discusses the design of the instruments, and progress in MMC detector fabrication. Details of the MMC fabrication have been discussed in an April 2016 report to DOE.

  15. Development of novel on-chip, customer-design spiral biasing adaptor on for Si drift detectors and detector arrays for X-ray and nuclear physics experiments

    Science.gov (United States)

    Li, Zheng; Chen, Wei

    2014-11-01

    A novel on-chip, customer-design spiral biasing adaptor (SBA) has been developed. A single SBA is used for biasing a Si drift detector (SDD) and SDD array. The use of an SBA reduces the biasing current. This paper shows the calculation of the geometry of an SBA and an SDD to get the best drift field in the SDD and SDD array. Prototype SBAs have been fabricated to verify the concept. Electrical measurements on these SBAs are in agreement with the expectations. The new SDD array with an SBA can be used for X-ray detection and in nuclear physics experiments.

  16. Development of novel on-chip, customer-design spiral biasing adaptor on for Si drift detectors and detector arrays for X-ray and nuclear physics experiments

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zheng, E-mail: lizheng@xtu.edu.cn [School of Materials, Optoelectronics and Physics, Xiangtan University, Xiangtan, Hunan 411105 (China); Chen, Wei [Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2014-11-21

    A novel on-chip, customer-design spiral biasing adaptor (SBA) has been developed. A single SBA is used for biasing a Si drift detector (SDD) and SDD array. The use of an SBA reduces the biasing current. This paper shows the calculation of the geometry of an SBA and an SDD to get the best drift field in the SDD and SDD array. Prototype SBAs have been fabricated to verify the concept. Electrical measurements on these SBAs are in agreement with the expectations. The new SDD array with an SBA can be used for X-ray detection and in nuclear physics experiments.

  17. Matching Two-dimensional Gel Electrophoresis' Spots

    DEFF Research Database (Denmark)

    Dos Anjos, António; AL-Tam, Faroq; Shahbazkia, Hamid Reza

    2012-01-01

    This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches. This ar......This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches...

  18. Mobility anisotropy of two-dimensional semiconductors

    Science.gov (United States)

    Lang, Haifeng; Zhang, Shuqing; Liu, Zhirong

    2016-12-01

    The carrier mobility of anisotropic two-dimensional semiconductors under longitudinal acoustic phonon scattering was theoretically studied using deformation potential theory. Based on the Boltzmann equation with the relaxation time approximation, an analytic formula of intrinsic anisotropic mobility was derived, showing that the influence of effective mass on mobility anisotropy is larger than those of deformation potential constant or elastic modulus. Parameters were collected for various anisotropic two-dimensional materials (black phosphorus, Hittorf's phosphorus, BC2N , MXene, TiS3, and GeCH3) to calculate their mobility anisotropy. It was revealed that the anisotropic ratio is overestimated by the previously described method.

  19. Towards two-dimensional search engines

    OpenAIRE

    Ermann, Leonardo; Chepelianskii, Alexei D.; Shepelyansky, Dima L.

    2011-01-01

    We study the statistical properties of various directed networks using ranking of their nodes based on the dominant vectors of the Google matrix known as PageRank and CheiRank. On average PageRank orders nodes proportionally to a number of ingoing links, while CheiRank orders nodes proportionally to a number of outgoing links. In this way the ranking of nodes becomes two-dimensional that paves the way for development of two-dimensional search engines of new type. Statistical properties of inf...

  20. Comparison of Thermal Detector Arrays for Off-Axis THz Holography and Real-Time THz Imaging.

    Science.gov (United States)

    Hack, Erwin; Valzania, Lorenzo; Gäumann, Gregory; Shalaby, Mostafa; Hauri, Christoph P; Zolliker, Peter

    2016-02-06

    In terahertz (THz) materials science, imaging by scanning prevails when low power THz sources are used. However, the application of array detectors operating with high power THz sources is increasingly reported. We compare the imaging properties of four different array detectors that are able to record THz radiation directly. Two micro-bolometer arrays are designed for infrared imaging in the 8-14 μm wavelength range, but are based on different absorber materials (i) vanadium oxide; (ii) amorphous silicon; (iii) a micro-bolometer array optimized for recording THz radiation based on silicon nitride; and (iv) a pyroelectric array detector for THz beam profile measurements. THz wavelengths of 96.5 μm, 118.8 μm, and 393.6 μm from a powerful far infrared laser were used to assess the technical performance in terms of signal to noise ratio, detector response and detectivity. The usefulness of the detectors for beam profiling and digital holography is assessed. Finally, the potential and limitation for real-time digital holography are discussed.

  1. Comparison of Thermal Detector Arrays for Off-Axis THz Holography and Real-Time THz Imaging

    Directory of Open Access Journals (Sweden)

    Erwin Hack

    2016-02-01

    Full Text Available In terahertz (THz materials science, imaging by scanning prevails when low power THz sources are used. However, the application of array detectors operating with high power THz sources is increasingly reported. We compare the imaging properties of four different array detectors that are able to record THz radiation directly. Two micro-bolometer arrays are designed for infrared imaging in the 8–14 μm wavelength range, but are based on different absorber materials (i vanadium oxide; (ii amorphous silicon; (iii a micro-bolometer array optimized for recording THz radiation based on silicon nitride; and (iv a pyroelectric array detector for THz beam profile measurements. THz wavelengths of 96.5 μm, 118.8 μm, and 393.6 μm from a powerful far infrared laser were used to assess the technical performance in terms of signal to noise ratio, detector response and detectivity. The usefulness of the detectors for beam profiling and digital holography is assessed. Finally, the potential and limitation for real-time digital holography are discussed.

  2. Attenuation study for Tibet Water Cherenkov Muon Detector Array-A

    CERN Document Server

    Gou, Quanbu; Liu, Cheng; Feng, Zhaoyang; Qian, Xiangli; Hou, Zhengtao

    2011-01-01

    The attenuation study of the long cable used in Tibet Water Cherenkov Muon Detector Array-A, called Tibet MD-A (one of 12 Tibet MD detectors), under the 37000 m2 Tibet air shower array, is reported. The cable frequency response is measured by using the sinusoidal signals, with which the influence of the cable on the pulse rise time is obtained. For the reason that the commercial 20 inch PMT (R3600_06) has a waterproof connection with the signal cable, one end of the signal cable is permanently connected to the PMT. Terminal reflection method is tested and used for measuring the signal attenuation. During the measurement, a practical way to eliminate the uncertainty caused by the baseline of the signal is achieved. To check the terminal reflection method, comparison measurement between it and QDC data taking method are carried out by using open-ended cables. The confirmed terminal reflection method is a fast and convenient method being suitable to online measure the signal attenuation for Tibet MD-A. The measu...

  3. Performance analysis of MIMO FSO systems with radial array beams and finite sized detectors

    Science.gov (United States)

    Gökçe, Muhsin C.; Kamacıoǧlu, Canan; Uysal, Murat; Baykal, Yahya

    2014-10-01

    Multiple-input multiple-output (MIMO) systems are employed in free space optical (FSO) links to mitigate the degrading effects of atmospheric turbulence. In this paper, we consider a MIMO FSO system with practical transmitter and receiver configurations that consists of a radial laser array with Gaussian beams and finite sized detectors. We formulate the average received intensity and the power scinitillation as a function of the receiver coordinates in the presence of weak atmospheric turbulence by using the extended Huygens-Fresnel principle. Then, integrations over the finite sized multiple detectors are performed and the effect of the receiver aperture averaging is quantified. We further derive an outage probability expression of this MIMO system in the presence of turbulence-induced fading channels. Using the derived expressions, we demonstrate the effect of several practical system parameters such as the ring radius, the number of array beamlets, the source size, the link length, structure constant and the receiver aperture radius on the system performance.

  4. Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance

    Science.gov (United States)

    Guillot, Mathieu; Gingras, Luc; Archambault, Louis; Beddar, Sam; Beaulieu, Luc

    2013-07-01

    The purposes of this work are to assess the performance of a 2D plastic scintillation detectors array prototype for quality assurance in intensity-modulated radiation therapy (IMRT) and to determine its sensitivity and specificity to positioning errors of one multileaf collimator (MLC) leaf and one MLC leaf bank by applying the principles of signal detection theory. Ten treatment plans (step-and-shoot delivery) and one volumetric modulated arc therapy plan were measured and compared to calculations from two treatment-planning systems (TPSs) and to radiochromic films. The averages gamma passing rates per beam found for the step-and-shoot plans were 95.8% for the criteria (3%, 2 mm), 97.8% for the criteria (4%, 2 mm), and 98.1% for the criteria (3%, 3 mm) when measurements were compared to TPS calculations. The receiver operating characteristic curves for the one leaf errors and one leaf bank errors were determined from simulations (theoretical upper limits) and measurements. This work concludes that arrays of plastic scintillation detectors could be used for IMRT quality assurance in clinics. The use of signal detection theory could improve the quality of dosimetric verifications in radiation therapy by providing optimal discrimination criteria for the detection of different classes of errors.

  5. CMOS detector arrays in a virtual 10-kilopixel camera for coherent terahertz real-time imaging.

    Science.gov (United States)

    Boppel, Sebastian; Lisauskas, Alvydas; Max, Alexander; Krozer, Viktor; Roskos, Hartmut G

    2012-02-15

    We demonstrate the principle applicability of antenna-coupled complementary metal oxide semiconductor (CMOS) field-effect transistor arrays as cameras for real-time coherent imaging at 591.4 GHz. By scanning a few detectors across the image plane, we synthesize a focal-plane array of 100×100 pixels with an active area of 20×20 mm2, which is applied to imaging in transmission and reflection geometries. Individual detector pixels exhibit a voltage conversion loss of 24 dB and a noise figure of 41 dB for 16 μW of the local oscillator (LO) drive. For object illumination, we use a radio-frequency (RF) source with 432 μW at 590 GHz. Coherent detection is realized by quasioptical superposition of the image and the LO beam with 247 μW. At an effective frame rate of 17 Hz, we achieve a maximum dynamic range of 30 dB in the center of the image and more than 20 dB within a disk of 18 mm diameter. The system has been used for surface reconstruction resolving a height difference in the μm range.

  6. Far infrared thermal detectors for laser radiometry using a carbon nanotube array

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, John H.; Lee, Bob; Grossman, Erich N.

    2011-07-20

    We present a description of a 1.5 mm long, vertically aligned carbon nanotube array (VANTA) on a thermopile and separately on a pyroelectric detector. Three VANTA samples, having average lengths of 40 {mu}m, 150 {mu}m, and 1.5 mm were evaluated with respect to reflectance at a laser wavelength of 394 {mu}m(760 GHz), and we found that the reflectance decreases substantially with increasing tube length, ranging from 0.38 to 0.23 to 0.01, respectively. The responsivity of the thermopile by electrical heating (98.4 mA/W) was equal to that by optical heating (98.0 mA/W) within the uncertainty of the measurement. We analyzed the frequency response and temporal response and found a thermal decay period of 500 ms, which is consistent with the specific heat of comparable VANTAs in the literature. The extremely low (0.01) reflectance of the 1.5 mm VANTAs and the fact that the array is readily transferable to the detector's surface is, to our knowledge, unprecedented.

  7. Spectrum measurement with the Telescope Array Low Energy Extension (TALE) fluorescence detector

    Science.gov (United States)

    Zundel, Zachary James

    The Telescope Array (TA) experiment is the largest Ultra High Energy cosmic ray observatory in the northern hemisphere and is designed to be sensitive to cosmic ray air showers above 1018eV. Despite the substantial measurements made by TA and AUGER (the largest cosmic ray observatory in the southern hemisphere), there remains uncertainty about whether the highest energy cosmic rays are galactic or extragalactic in origin. Locating features in the cosmic ray energy spectrum below 1018eV that indicate a transition from galactic to extragalactic sources would clarify the interpretation of measurements made at the highest energies. The Telescope Array Low Energy Extension (TALE) is designed to extend the energy threshold of the TA observatory down to 1016.5eV in order to make such measurements. This dissertation details the construction, calibration, and operation of the TALE flu- orescence detector. A measurement of the flux of cosmic rays in the energy range of 1016.5 -- 1018.5eV is made using the monocular data set taken between September 2013 and January 2014. The TALE fluorescence detector observes evidence for a softening of the cosmic spectrum at 1017.25+/-0.5eV. The evidence of a change in the spectrum motivates continued study of 1016.5 -- 1018.5eV cosmic rays.

  8. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada)

    2012-01-15

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone

  9. Proton irradiation results for long-wave HgCdTe infrared detector arrays for Near-Earth Object Camera

    Science.gov (United States)

    Dorn, Meghan L.; Pipher, Judith L.; McMurtry, Craig; Hartman, Spencer; Mainzer, Amy; McKelvey, Mark; McMurray, Robert; Chevara, David; Rosser, Joshua

    2016-07-01

    HgCdTe detector arrays with a cutoff wavelength of ˜10 μm intended for the Near-Earth Object Camera (NEOCam) space mission were subjected to proton-beam irradiation at the University of California Davis Crocker Nuclear Laboratory. Three arrays were tested-one with 800-μm substrate intact, one with 30-μm substrate, and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe detector is grown, has been shown to produce luminescence in shorter wave HgCdTe arrays that causes an elevated signal in nonhit pixels when subjected to proton irradiation. This testing was conducted to ascertain whether or not full substrate removal is necessary. At the dark level of the dewar, we detect no luminescence in nonhit pixels during proton testing for both the substrate-removed detector array and the array with 30-μm substrate. The detector array with full 800-μm substrate exhibited substantial photocurrent for a flux of 103 protons/cm2 s at a beam energy of 18.1 MeV (˜750 e-/s) and 34.4 MeV (˜65 e-/s). For the integrated space-like ambient proton flux level measured by the Spitzer Space Telescope, the luminescence would be well below the NEOCam dark current requirement of <200 e-/s, but the pattern of luminescence could be problematic, possibly complicating calibration.

  10. A 2-D Array of Superconducting Magnesium Diboride (MgB2) Far-IR Thermal Detectors for Planetary Exploration

    Science.gov (United States)

    Lakew, Brook

    2009-01-01

    A 2-D array of superconducting Magnesium Diboride(MgB2) far IR thermal detectors has been fabricated. Such an array is intended to be at the focal plane of future generation thermal imaging far-IR instruments that will investigate the outer planets and their icy moons. Fabrication and processing of the pixels of the array as well as noise characterization of architectured MgB2 thin films will be presented. Challenges and solutions for improving the performance of the array will be discussed.

  11. Homogenization of Two-Dimensional Phononic Crystals at Low Frequencies

    Institute of Scientific and Technical Information of China (English)

    NI Qing; CHENG Jian-Chun

    2005-01-01

    @@ Effective velocities of elastic waves propagating in two-dimensional phononic crystal at low frequencies are analysed theoretically, and exact analytical formulas for effective velocities of elastic waves are derived according to the method presented by Krokhin et al. [Phys. Rev. Lett. 91 (2003) 264302]. Numerical calculations for phononic crystals consisted of array of Pb cylinders embedded in epoxy show that the composites have distinct anisotropy at low filling fraction. The anisotropy increases as the filling fraction increases, while as the filling fraction closes to the limitation, the anisotropy decreases.

  12. A dynamic resistance nonuniformity compensation circuit for uncooled microbolometer detector arrays

    Science.gov (United States)

    Yildirim, Omer Ozgur; Akin, Tayfun

    2006-05-01

    This paper presents a new approach for compensating resistance nonuniformity of uncooled microbolometers by adjusting the bias currents of both detector and reference pixels. Contrary to conventional nonuniformity compensation circuits, this approach eliminates the need for digital-to-analog converters (DACs), which usually occupy a large area, dissipate high power, and require complicated external circuitry with high frequency data transfer to the microbolometer chip. The proposed circuit uses a feedback structure that dynamically changes the bias currents of the reference and detector pixels and does not need complicated external circuitry. A special feature of the circuit is that it provides continuous compensation for the detector and reference resistances due to temperature changes over time. The circuit is implemented in a 0.6μm 5V CMOS process and occupies an area of only 160μm × 630μm. Test results of the prototype circuit show that the circuit reduces the offset current due to resistance nonuniformity about 2.35% of its uncompensated value, i.e., an improvement of about 42.5 times is achieved, independent of the nonuniformity amount. The circuit achieves this compensation in 12μsec. Considering its simplicity and low cost, this approach is suitable for large array commercial infrared imaging systems.

  13. A Deuterated Neutron Detector Array For Nuclear (Astro)Physics Studies

    Science.gov (United States)

    Almaraz-Calderon, Sergio; Asher, B. W.; Barber, P.; Hanselman, K.; Perello, J. F.

    2016-09-01

    The properties of neutron-rich nuclei are at the forefront of research in nuclear structure, nuclear reactions and nuclear astrophysics. The advent of intense rare isotope beams (RIBs) has opened a new door for studies of systems with very short half-lives and possible fascinating properties. Neutron spectroscopic techniques become increasingly relevant when these neutron rich nuclei are used in a variety of experiments. At Florida State University, we are developing a neutron detector array that will allow us to perform high-resolution neutron spectroscopic studies with stable and radioactive beams. The neutron detection system consists of 16 deuterated organic liquid scintillation detectors with fast response and pulse-shape discrimination capabilities. In addition to these properties, there is the potential to use the structure in the pulse-height spectra to extract the energy of the neutrons and thus produce directly excitation spectra. This type of detector uses deuterated benzene (C6D6) as the liquid scintillation medium. The asymmetric nature of the scattering between a neutron and a deuterium in the center of mass produces a pulse-height spectrum from the deuterated scintillator which contains useful information on the initial energy of the neutron. Work supported in part by the State of Florida and NSF Grant No. 1401574.

  14. Non-local means-based nonuniformity correction for infrared focal-plane array detectors

    Science.gov (United States)

    Yu, Hui; Zhang, Zhi-jie; Chen, Fu-sheng; Wang, Chen-sheng

    2014-11-01

    The infrared imaging systems are normally based on the infrared focal-plane array (IRFPA) which can be considered as an array of independent detectors aligned at the focal plane of the imaging system. Unfortunately, every detector on the IRFPA may have a different response to the same input infrared signal which is known as the nonuniformity problem. Then we can observe the fixed pattern noise (FPN) from the resulting images. Standard nonuniformity correction (NUC) methods need to be recalibrated after a short period of time due the temporal drift of the FPN. Scene-based nonuniformity correction (NUC) techniques eliminate the need for calibration by correction coefficients based on the scene being viewed. However, in the scene-based NUC method the problem of ghosting artifacts widely seriously decreases the image quality, which can degrade the performance of many applications such as target detection and track. This paper proposed an improved scene-based method based on the retina-like neural network approach. The method incorporates the use of non-local means (NLM) method into the estimation of the gain and the offset of each detector. This method can not only estimates the accurate correction coefficient but also restrict the ghosting artifacts efficiently. The proposed method relies on the use of NLM method which is a very successful image denoising method. And then the NLM used here can preserve the image edges efficiently and obtain a reliable spatial estimation. We tested the proposed NUC method by applying it to an IR sequence of frames. The performance of the proposed method was compared the other well-established adaptive NUC techniques.

  15. Piezoelectricity in Two-Dimensional Materials

    KAUST Repository

    Wu, Tao

    2015-02-25

    Powering up 2D materials: Recent experimental studies confirmed the existence of piezoelectricity - the conversion of mechanical stress into electricity - in two-dimensional single-layer MoS2 nanosheets. The results represent a milestone towards embedding low-dimensional materials into future disruptive technologies. © 2015 Wiley-VCH Verlag GmbH & Co. KGaA.

  16. Two-Dimensional Toda-Heisenberg Lattice

    Directory of Open Access Journals (Sweden)

    Vadim E. Vekslerchik

    2013-06-01

    Full Text Available We consider a nonlinear model that is a combination of the anisotropic two-dimensional classical Heisenberg and Toda-like lattices. In the framework of the Hirota direct approach, we present the field equations of this model as a bilinear system, which is closely related to the Ablowitz-Ladik hierarchy, and derive its N-soliton solutions.

  17. A novel two dimensional particle velocity sensor

    NARCIS (Netherlands)

    Pjetri, Olti; Wiegerink, Remco J.; Lammerink, Theo S.; Krijnen, Gijs J.

    2013-01-01

    In this paper we present a two wire, two-dimensional particle velocity sensor. The miniature sensor of size 1.0x2.5x0.525 mm, consisting of only two crossed wires, shows excellent directional sensitivity in both directions, thus requiring no directivity calibration, and is relatively easy to fabrica

  18. Two-dimensional magma-repository interactions

    NARCIS (Netherlands)

    Bokhove, O.

    2001-01-01

    Two-dimensional simulations of magma-repository interactions reveal that the three phases --a shock tube, shock reflection and amplification, and shock attenuation and decay phase-- in a one-dimensional flow tube model have a precursor. This newly identified phase ``zero'' consists of the impact of

  19. A two-dimensional Dirac fermion microscope

    DEFF Research Database (Denmark)

    Bøggild, Peter; Caridad, Jose; Stampfer, Christoph

    2017-01-01

    in the solid state. Here we provide a perspective view on how a two-dimensional (2D) Dirac fermion-based microscope can be realistically implemented and operated, using graphene as a vacuum chamber for ballistic electrons. We use semiclassical simulations to propose concrete architectures and design rules of 2...

  20. A new DOI detector design using discrete crystal array with depth-dependent reflector patterns and single-ended readout

    Science.gov (United States)

    Lee, Seung-Jae; Lee, Chaeyeong; Kang, Jihoon; Chung, Yong Hyun

    2017-01-01

    We developed a depth of interaction (DOI) positron emission tomography (PET) detector using depth-dependent reflector patterns in a discrete crystal array. Due to the different reflector patterns at depth, light distribution was changed relative to depth. As a preliminary experiment, we measured DOI detector module crystal identification performance. The crystal consisted of a 9×9 array of 2 mmx2 mmx20 mm lutetium-yttrium oxyorthosilicate (LYSO) crystals. The crystal array was optically coupled to a 64-channel position-sensitive photomultiplier tube with a 2 mmx2 mm anode size and an 18.1 mmx18.1 mm effective area. We obtained the flood image with an Anger-type calculation. DOI layers and 9×9 pixels were well distinguished in the obtained images. Preclinical PET scanners based on this detector design offer the prospect of high and uniform spatial resolution.

  1. A 2×2 array of EMCCD-based solid state x-ray detectors.

    Science.gov (United States)

    Sharma, P; Swetadri Vasan, S N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S

    2012-01-01

    We have designed and developed a new solid-state x-ray imaging system that consists of a 2×2 array of electron multiplying charge coupled devices (EMCCDs). This system is intended for fluoroscopic and angiographic medical imaging. The key components are the four 1024 × 1024 pixel EMCCDs with a pixel size of 13 × 13 µm(2). Each EMCCD is bonded to a fiber optic plate (FOP), and optically coupled to a 350 µm thick micro-columnar CsI(TI) scintillator via a 3.22∶1 fiber optic taper (FOT). The detector provides x-ray images of 9 line pairs/mm resolution at 15 frames/sec and real-time live video at 30 frames/sec with binning at a lower resolution, independent of the electronic gain applied to the EMCCD. The total field of view (FOV) of the array is 8.45 cm × 8.45 cm. The system is designed to also provide the ability to do region-of- interest imaging (ROI) by selectively enabling individual modules of the array.

  2. LENDA, a Low Energy Neutron Detector Array for experiments with radioactive beams in inverse kinematics

    CERN Document Server

    Perdikakis, G; Austin, Sam M; Bazin, D; Caesar, C; Cannon, S; Deaven, J M; Doster, H J; Guess, C J; Hitt, G W; Marks, J; Meharchand, R; Nguyen, D T; Peterman, D; Prinke, A; Scott, M; Shimbara, Y; Thorne, K; Valdez, L; Zegers, R G T

    2011-01-01

    The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Lab- oratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p, n) charge-exchange reactions at intermediate energies (> 100 MeV/u). It can be used, however, for any reaction study that involves emission of low energy neutrons (150 keV - 10 MeV). The array consists of 24 plastic scintillator bars and is capable of registering the recoiling neutron energy and angle with high detection efficiency. The neutron energy is determined by the time-of-flight technique, while the position of interaction is deduced using the timing and energy information from the two photomultipliers of each bar. A simple test setup utilizing radioactive sources has been used to characterize the array. Results of test measurements are compared with simulations. A neut...

  3. High-performance SPAD array detectors for parallel photon timing applications

    Science.gov (United States)

    Rech, I.; Cuccato, A.; Antonioli, S.; Cammi, C.; Gulinatti, A.; Ghioni, M.

    2012-02-01

    Over the past few years there has been a growing interest in monolithic arrays of single photon avalanche diodes (SPAD) for spatially resolved detection of faint ultrafast optical signals. SPADs implemented in planar technologies offer the typical advantages of microelectronic devices (small size, ruggedness, low voltage, low power, etc.). Furthermore, they have inherently higher photon detection efficiency than PMTs and are able to provide, beside sensitivities down to single-photons, very high acquisition speeds. In order to make SPAD array more and more competitive in time-resolved application it is necessary to face problems like electrical crosstalk between adjacent pixel, moreover all the singlephoton timing electronics with picosecond resolution has to be developed. In this paper we present a new instrument suitable for single-photon imaging applications and made up of 32 timeresolved parallel channels. The 32x1 pixel array that includes SPAD detectors represents the system core, and an embedded data elaboration unit performs on-board data processing for single-photon counting applications. Photontiming information is exported through a custom parallel cable that can be connected to an external multichannel TCSPC system.

  4. Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array

    CERN Document Server

    Huang, Ying Zhangm Jing; Zhai, Liu-Ming; Chen, Xu; Hu, Xiao-Bin; Lin, Yu-Hui; Zhang, Xue-Yao; Feng, Cun-Feng; Jia, Huan-Yu; Zhou, Xun-Xiu; Dan-Zen, Luo-bu; Chen, Tian-Lu; Laba, Ci-Ren; Mao-Yuan,; Gao, Qi; Zha-xi, Ci-ren

    2016-01-01

    A new hybrid experiment has been constructed to measure the chemical composition of cosmic rays around the "knee" in the wide energy range by the Tibet AS$\\gamma$ collaboration at Tibet, China, since 2014. They consist of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD). In order to obtain the primary proton, helium and iron spectra and their "knee" positions in the energy range lower than $10^{16}$ eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100 - $10^{6}$ photoelectrons (PEs) according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. This is the first comparison between R5912-PMT and CR365-PMT. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirem...

  5. LENDA: A low energy neutron detector array for experiments with radioactive beams in inverse kinematics

    Energy Technology Data Exchange (ETDEWEB)

    Perdikakis, G., E-mail: perdikak@nscl.msu.edu [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute of Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Sasano, M.; Austin, Sam M. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute of Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Bazin, D. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Caesar, C. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute of Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Cannon, S. [Hastings College, Hastings, NE 68901 (United States); Deaven, J.M.; Doster, H.J.; Guess, C.J.; Hitt, G.W. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute of Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Marks, J. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Meharchand, R. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute of Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Nguyen, D.T. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Peterman, D. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); and others

    2012-09-11

    The Low Energy Neutron Detector Array (LENDA) is a neutron time-of-flight (TOF) spectrometer developed at the National Superconducting Cyclotron Laboratory (NSCL) for use in inverse kinematics experiments with rare isotope beams. Its design has been motivated by the need to study the spin-isospin response of unstable nuclei using (p,n) charge-exchange reactions at intermediate energies (>100MeV/u). It can be used, however, for any reaction study that involves emission of low energy neutrons (150 keV to 10 MeV). The array consists of 24 plastic scintillator bars and is capable of registering the recoiling neutron energy and angle with high detection efficiency. The neutron energy is determined by the time-of-flight technique, while the position of interaction is deduced using the timing and energy information from the two photomultipliers of each bar. A simple test setup utilizing radioactive sources has been used to characterize the array. Results of test measurements are compared with simulations. A neutron energy threshold of <150keV, an intrinsic time (position) resolution of {approx} 400 ps ({approx} 6 cm) and an efficiency >20% for neutrons below 4 MeV have been obtained.

  6. Signal-Conditioning Block of a 1 × 200 CMOS Detector Array for a Terahertz Real-Time Imaging System

    Directory of Open Access Journals (Sweden)

    Jong-Ryul Yang

    2016-03-01

    Full Text Available A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size including an integrated antenna is comparable to the wavelength of the THz wave for the imaging system, inevitably carries wide pixel-to-pixel variation. To make the variant outputs from the array uniform, the proposed signal conditioning block calibrates the responsivity of each pixel by controlling the gate bias of each detector and the voltage gain of the lock-in amplifiers in the block. The gate bias of each detector is modulated to 1 MHz to improve the signal-to-noise ratio of the imaging system via the electrical modulation by the conditioning block. In addition, direct current (DC offsets of the detectors in the array are cancelled by initializing the output voltage level from the block. Real-time imaging using the proposed signal conditioning block is demonstrated by obtaining images at the rate of 19.2 frame-per-sec of an object moving on the conveyor belt with a scan width of 20 cm and a scan speed of 25 cm/s.

  7. Signal-Conditioning Block of a 1 × 200 CMOS Detector Array for a Terahertz Real-Time Imaging System.

    Science.gov (United States)

    Yang, Jong-Ryul; Lee, Woo-Jae; Han, Seong-Tae

    2016-03-02

    A signal conditioning block of a 1 × 200 Complementary Metal-Oxide-Semiconductor (CMOS) detector array is proposed to be employed with a real-time 0.2 THz imaging system for inspecting large areas. The plasmonic CMOS detector array whose pixel size including an integrated antenna is comparable to the wavelength of the THz wave for the imaging system, inevitably carries wide pixel-to-pixel variation. To make the variant outputs from the array uniform, the proposed signal conditioning block calibrates the responsivity of each pixel by controlling the gate bias of each detector and the voltage gain of the lock-in amplifiers in the block. The gate bias of each detector is modulated to 1 MHz to improve the signal-to-noise ratio of the imaging system via the electrical modulation by the conditioning block. In addition, direct current (DC) offsets of the detectors in the array are cancelled by initializing the output voltage level from the block. Real-time imaging using the proposed signal conditioning block is demonstrated by obtaining images at the rate of 19.2 frame-per-sec of an object moving on the conveyor belt with a scan width of 20 cm and a scan speed of 25 cm/s.

  8. Electronics and data acquisition system of the extensive air shower detector array at the University of Puebla

    Science.gov (United States)

    Perez, E.; Salazar, H.; Villasenor, L.; Martinez, O.; Conde, R.; Murrieta, T.

    Field programmable gate arrays (FPGAs) are playing an increasing role in DAQ systems in cosmic ray experiments due to their high speed and integration and their low cost and low power comsumption. In this paper we describe in detail the new electronics and data acquisition system based on FPGA boards of the extensive air shower detector array built in the Campus of the University of Puebla. The purpose of this detector array is to measure the energy and arrival direction of primary cosmic rays with energies around 1015 eV. The array consists of 10 liquid scintillator detectors and 6 water Cherenkov detectors (of 1.86 m2 cross section), distributed in a square grid with a detector spacing of 20 m over an area of 4000 m2. The electronics described also makes use of analog to digital converters with a resolution of 10 bits and sampling speeds of 100 MS/s to digitize the PMT signals. We also discuss the advantages of discriminating the PMT signals inside the FPGAs with respect to the conventional use of dedicated discrimination circuits.

  9. SiPM detectors for the ASTRI project in the framework of the Cherenkov Telescope Array

    Science.gov (United States)

    Billotta, Sergio; Marano, Davide; Bonanno, Giovanni; Belluso, Massimiliano; Grillo, Alessandro; Garozzo, Salvatore; Romeo, Giuseppe; Timpanaro, Maria Cristina; Maccarone, Maria Concetta C.; Catalano, Osvaldo; La Rosa, Giovanni; Sottile, Giuseppe; Impiombato, Domenico; Gargano, Carmelo; Giarrusso, Salavtore

    2014-07-01

    The Cherenkov Telescope Array (CTA) is a worldwide new generation project aimed at realizing an array of a hundred ground based gamma-ray telescopes. ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is the Italian project whose primary target is the development of an end-to-end prototype, named ASTRI SST-2M, of the CTA small size class of telescopes devoted to investigation of the highest energy region, from 1 to 100 TeV. Next target is the implementation of an ASTRI/CTA mini-array based on seven identical telescopes. Silicon Photo-Multipliers (SiPMs) are the semiconductor photosensor devices designated to constitute the camera detection system at the focal plane of the ASTRI telescopes. SiPM photosensors are suitable for the detection of the Cherenkov flashes, since they are very fast and sensitive to the light in the 300-700nm wavelength spectrum. Their drawbacks compared to the traditional photomultiplier tubes are high dark count rates, after-pulsing and optical cross-talk contributions, and intrinsic gains strongly dependent on temperature. Nonetheless, for a single pixel, the dark count rate is well below the Night Sky Background, the effects of cross-talk and afterpulses are typically lower than 20%, and the gain can be kept stable against temperature variations by means of adequate bias voltage compensation strategies. This work presents and discusses some experimental results from a large set of measurements performed on the SiPM sensors to be used for the ASTRI SST-2M prototype camera and on recently developed detectors demonstrating outstanding performance for the future evolution of the project in the ASTRI/CTA mini-array.

  10. Large arrays of dual-polarized multichroic TES detectors for CMB measurements with the SPT-3G receiver

    Science.gov (United States)

    Posada, Chrystian M.; Ade, Peter A. R.; Anderson, Adam J.; Avva, Jessica; Ahmed, Zeeshan; Arnold, Kam S.; Austermann, Jason; Bender, Amy N.; Benson, Bradford A.; Bleem, Lindsey; Byrum, Karen; Carlstrom, John E.; Carter, Faustin W.; Chang, Clarence; Cho, Hsiao-Mei; Cukierman, Ari; Czaplewski, David A.; Ding, Junjia; Divan, Ralu N. S.; de Haan, Tijmen; Dobbs, Matt; Dutcher, Daniel; Everett, Wenderline; Gannon, Renae N.; Guyser, Robert J.; Halverson, Nils W.; Harrington, Nicholas L.; Hattori, Kaori; Henning, Jason W.; Hilton, Gene C.; Holzapfel, William L.; Huang, Nicholas; Irwin, Kent D.; Jeong, Oliver; Khaire, Trupti; Korman, Milo; Kubik, Donna L.; Kuo, Chao-Lin; Lee, Adrian T.; Leitch, Erik M.; Lendinez Escudero, Sergi; Meyer, Stephan S.; Miller, Christina S.; Montgomery, Joshua; Nadolski, Andrew; Natoli, Tyler J.; Nguyen, Hogan; Novosad, Valentyn; Padin, Stephen; Pan, Zhaodi; Pearson, John E.; Rahlin, Alexandra; Reichardt, Christian L.; Ruhl, John E.; Saliwanchik, Benjamin; Shirley, Ian; Sayre, James T.; Shariff, Jamil A.; Shirokoff, Erik D.; Stan, Liliana; Stark, Antony A.; Sobrin, Joshua; Story, Kyle; Suzuki, Aritoki; Tang, Qing Yang; Thakur, Ritoban B.; Thompson, Keith L.; Tucker, Carole E.; Vanderlinde, Keith; Vieira, Joaquin D.; Wang, Gensheng; Whitehorn, Nathan; Yefremenko, Volodymyr; Yoon, Ki Won

    2016-07-01

    Detectors for cosmic microwave background (CMB) experiments are now essentially background limited, so a straightforward alternative to improve sensitivity is to increase the number of detectors. Large arrays of multichroic pixels constitute an economical approach to increasing the number of detectors within a given focal plane area. Here, we present the fabrication of large arrays of dual-polarized multichroic transition-edge-sensor (TES) bolometers for the South Pole Telescope third-generation CMB receiver (SPT-3G). The complete SPT-3G receiver will have 2690 pixels, each with six detectors, allowing for individual measurement of three spectral bands (centered at 95 GHz, 150 GHz and 220 GHz) in two orthogonal polarizations. In total, the SPT-3G focal plane will have 16140 detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a niobium microstrip transmission line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES sensors. Detectors are read out using a 64x frequency domain multiplexing (fMux) scheme. The microfabrication of the SPT-3G detector arrays involves a total of 18 processes, including 13 lithography steps. Together with the fabrication process, the effect of processing on the Ti/Au TES's Tc is discussed. In addition, detectors fabricated with Ti/Au TES films with Tc between 400 mK 560 mK are presented and their thermal characteristics are evaluated. Optical characterization of the arrays is presented as well, indicating that the response of the detectors is in good agreement with the design values for all three spectral bands (95 GHz, 150 GHz, and 220 GHz). The measured optical efficiency of the detectors is between 0.3 and 0.8. Results discussed here are extracted from a batch of research of development wafers used to develop the baseline process for the fabrication of the arrays of detectors to be deployed with the SPT-3G receiver. Results from

  11. Two dimensional radiated power diagnostics on Alcator C-Moda)

    Science.gov (United States)

    Reinke, M. L.; Hutchinson, I. H.

    2008-10-01

    The radiated power diagnostics for the Alcator C-Mod tokamak have been upgraded to measure two dimensional structure of the photon emissivity profile in order to investigate poloidal asymmetries in the core radiation. Commonly utilized unbiased absolute extreme ultraviolet (AXUV) diode arrays view the plasma along five different horizontal planes. The layout of the diagnostic set is shown and the results from calibrations and recent experiments are discussed. Data showing a significant, 30%-40%, inboard/outboard emissivity asymmetry during ELM-free H-mode are presented. The ability to use AXUV diode arrays to measure absolute radiated power is explored by comparing diode and resistive bolometer-based emissivity profiles for highly radiative L-mode plasmas seeded with argon. Emissivity profiles match in the core but disagree radially outward resulting in an underprediction of Prad of nearly 50% by the diodes compared to Prad determined using resistive bolometers.

  12. Two-Dimensional Crystallization of the Ca(2+)-ATPase for Electron Crystallography.

    Science.gov (United States)

    Glaves, John Paul; Primeau, Joseph O; Young, Howard S

    2016-01-01

    Electron crystallography of two-dimensional crystalline arrays is a powerful alternative for the structure determination of membrane proteins. The advantages offered by this technique include a native membrane environment and the ability to closely correlate function and dynamics with crystalline preparations and structural data. Herein, we provide a detailed protocol for the reconstitution and two-dimensional crystallization of the sarcoplasmic reticulum calcium pump (also known as Ca(2+)-ATPase or SERCA) and its regulatory subunits phospholamban and sarcolipin.

  13. Two-Dimensional Arrays of Neutral Atom Quantum Gates

    Science.gov (United States)

    2012-10-20

    Isenhower, X. Zhang, A. Gill, T. Walker, M. Saffman. Deterministic entanglement of two neutral atoms via Rydberg blockade, Physical Review A, (09 2010...squeezing of atomic ensembles by multicolor quantum nondemolition measurements, Physical Review A, (02 2009): 0. doi: 10.1103/PhysRevA.79.023831 10/19/2012...collective encoding in holmium atoms, Physical Review A, (07 2008): 0. doi: 10.1103/PhysRevA.78.012336 10/19/2012 10.00 M Saffman, X L Zhang, A T

  14. Measurements on Two-Dimensional Arrays of Mesoscopic Josephson Junctions

    Science.gov (United States)

    1993-02-01

    are reasonably well- understood, with the possible exceptions of ballistic motion of vortices [van der Zant, et al. (1992b)] and the Aharonov - Casher (AC... effect , the magnetic analog of the Aharonov - Bohm effect (with the AC effect , it is theoretically predicted that one can measure the interference... Aharonov and Bohm (1959), and Aharonov and Casher (1984). 148 REFERENCES Aharonov , Y., and D. Bohm, Phys. Rev. B 3, 485 (1959). Aharonoy, Y., and A

  15. Electronics based on two-dimensional materials.

    Science.gov (United States)

    Fiori, Gianluca; Bonaccorso, Francesco; Iannaccone, Giuseppe; Palacios, Tomás; Neumaier, Daniel; Seabaugh, Alan; Banerjee, Sanjay K; Colombo, Luigi

    2014-10-01

    The compelling demand for higher performance and lower power consumption in electronic systems is the main driving force of the electronics industry's quest for devices and/or architectures based on new materials. Here, we provide a review of electronic devices based on two-dimensional materials, outlining their potential as a technological option beyond scaled complementary metal-oxide-semiconductor switches. We focus on the performance limits and advantages of these materials and associated technologies, when exploited for both digital and analog applications, focusing on the main figures of merit needed to meet industry requirements. We also discuss the use of two-dimensional materials as an enabling factor for flexible electronics and provide our perspectives on future developments.

  16. Two-dimensional ranking of Wikipedia articles

    Science.gov (United States)

    Zhirov, A. O.; Zhirov, O. V.; Shepelyansky, D. L.

    2010-10-01

    The Library of Babel, described by Jorge Luis Borges, stores an enormous amount of information. The Library exists ab aeterno. Wikipedia, a free online encyclopaedia, becomes a modern analogue of such a Library. Information retrieval and ranking of Wikipedia articles become the challenge of modern society. While PageRank highlights very well known nodes with many ingoing links, CheiRank highlights very communicative nodes with many outgoing links. In this way the ranking becomes two-dimensional. Using CheiRank and PageRank we analyze the properties of two-dimensional ranking of all Wikipedia English articles and show that it gives their reliable classification with rich and nontrivial features. Detailed studies are done for countries, universities, personalities, physicists, chess players, Dow-Jones companies and other categories.

  17. Two-Dimensional NMR Lineshape Analysis

    Science.gov (United States)

    Waudby, Christopher A.; Ramos, Andres; Cabrita, Lisa D.; Christodoulou, John

    2016-04-01

    NMR titration experiments are a rich source of structural, mechanistic, thermodynamic and kinetic information on biomolecular interactions, which can be extracted through the quantitative analysis of resonance lineshapes. However, applications of such analyses are frequently limited by peak overlap inherent to complex biomolecular systems. Moreover, systematic errors may arise due to the analysis of two-dimensional data using theoretical frameworks developed for one-dimensional experiments. Here we introduce a more accurate and convenient method for the analysis of such data, based on the direct quantum mechanical simulation and fitting of entire two-dimensional experiments, which we implement in a new software tool, TITAN (TITration ANalysis). We expect the approach, which we demonstrate for a variety of protein-protein and protein-ligand interactions, to be particularly useful in providing information on multi-step or multi-component interactions.

  18. Towards two-dimensional search engines

    CERN Document Server

    Ermann, Leonardo; Shepelyansky, Dima L

    2011-01-01

    We study the statistical properties of various directed networks using ranking of their nodes based on the dominant vectors of the Google matrix known as PageRank and CheiRank. On average PageRank orders nodes proportionally to a number of ingoing links, while CheiRank orders nodes proportionally to a number of outgoing links. In this way the ranking of nodes becomes two-dimensional that paves the way for development of two-dimensional search engines of new type. Information flow properties on PageRank-CheiRank plane are analyzed for networks of British, French and Italian Universities, Wikipedia, Linux Kernel, gene regulation and other networks. Methods of spam links control are also analyzed.

  19. Toward two-dimensional search engines

    Science.gov (United States)

    Ermann, L.; Chepelianskii, A. D.; Shepelyansky, D. L.

    2012-07-01

    We study the statistical properties of various directed networks using ranking of their nodes based on the dominant vectors of the Google matrix known as PageRank and CheiRank. On average PageRank orders nodes proportionally to a number of ingoing links, while CheiRank orders nodes proportionally to a number of outgoing links. In this way, the ranking of nodes becomes two dimensional which paves the way for the development of two-dimensional search engines of a new type. Statistical properties of information flow on the PageRank-CheiRank plane are analyzed for networks of British, French and Italian universities, Wikipedia, Linux Kernel, gene regulation and other networks. A special emphasis is done for British universities networks using the large database publicly available in the UK. Methods of spam links control are also analyzed.

  20. On the estimation of target depth using the single transmit multiple receive metal detector array

    Science.gov (United States)

    Ho, K. C.; Gader, P. D.

    2012-06-01

    This paper investigates the use of the Single Transmit Multiple Receive (STMR) metal detector (MD) array to estimate the depth of metal targets, such as 155mm shells. The depth estimation problem using MD has been investigated by a number of researchers and the processing was performed along the down-track. The proposed method takes a different approach by exploring the MD responses in cross-track to achieve the depth estimation. It is found that the normalized energy spread of the MD output is narrower for shallow targets and wider for deeper targets. Based on this observation, a method is derived to estimate the depth of a target. Experimental results from the data collected at an U.S. Army test site validate the performance of the proposed depth estimator.