WorldWideScience

Sample records for two-color infrared thermometer

  1. Two-color infrared detector

    Science.gov (United States)

    Klem, John F; Kim, Jin K

    2014-05-13

    A two-color detector includes a first absorber layer. The first absorber layer exhibits a first valence band energy characterized by a first valence band energy function. A barrier layer adjoins the first absorber layer at a first interface. The barrier layer exhibits a second valence band energy characterized by a second valence band energy function. The barrier layer also adjoins a second absorber layer at a second interface. The second absorber layer exhibits a third valence band energy characterized by a third valence band energy function. The first and second valence band energy functions are substantially functionally or physically continuous at the first interface and the second and third valence band energy functions are substantially functionally or physically continuous at the second interface.

  2. Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer.

    Science.gov (United States)

    Poveda, Vanessa de Brito; Nascimento, Ariane de Souza

    2016-01-01

    To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of ±0.2ºC. The operating room temperature remained between 19 and 21ºC. The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24°C lower (ptemperatura realizadas por meio de um termômetro timpânico por infravermelho e por um termômetro esofágico, durante o período intraoperatório. Realizou-se um estudo longitudinal, de medidas repetidas, incluindo sujeitos com idade igual ou superior a 18 anos, submetidos à cirurgia oncológica eletiva do sistema digestório, com duração da anestesia de, no mínimo, 1 hora. As medidas de temperatura eram realizadas, ao mesmo tempo, por meio de um termômetro esofágico calibrado e por termômetro timpânico por infravermelho calibrado, com precisão de leitura em laboratório de ±0,2ºC. A temperatura da sala operatória permaneceu entre 19 e 21ºC. Foram incluídos 51 pacientes, em sua maioria homens (51%), brancos (80,4%). Todos os pacientes foram aquecidos com o sistema de ar forçado aquecido, em média por 264,14 minutos (DP = 87,7). As duas medidas de temperatura não tiveram comportamento diferente ao longo do tempo (p = 0,2205), mas a medida timpânica foi consistentemente menor em 1,24°C (p temperaturas mais

  3. High speed infrared radiation thermometer, system, and method

    Science.gov (United States)

    Markham, James R.

    2002-01-01

    The high-speed radiation thermometer has an infrared measurement wavelength band that is matched to the infrared wavelength band of near-blackbody emittance of ceramic components and ceramic thermal barrier coatings used in turbine engines. It is comprised of a long wavelength infrared detector, a signal amplifier, an analog-to-digital converter, an optical system to collect radiation from the target, an optical filter, and an integral reference signal to maintain a calibrated response. A megahertz range electronic data acquisition system is connected to the radiation detector to operate on raw data obtained. Because the thermometer operates optimally at 8 to 12 .mu.m, where emittance is near-blackbody for ceramics, interferences to measurements performed in turbine engines are minimized. The method and apparatus are optimized to enable mapping of surface temperatures on fast moving ceramic elements, and the thermometer can provide microsecond response, with inherent self-diagnostic and calibration-correction features.

  4. Two-color photoionization and photoelectron studies by combining infrared and vacuum ultraviolet

    International Nuclear Information System (INIS)

    Ng, C.Y.

    2005-01-01

    Recent developments of two-color infrared (IR)-vacuum ultraviolet (VUV) and VUV-IR photoionization and photoelectron detection schemes for spectroscopic studies are described. By preparing molecules in selected rovibrational states by IR excitation prior to VUV-photoionization, state-selected and state-to-state photoionization cross sections can be obtained by IR-VUV-photoionization efficiency (IR-VUV-PIE) and IR-VUV-pulsed field ionization-photoelectron (IR-VUV-PFI-PE) measurements, respectively. Rotationally resolved autoionizing Rydberg states converging to excited ionic states, which cannot be observed by single-photon VUV-PIE measurements, can be examined by the IR-VUV-PIE scheme. By monitoring the photoion and the PFI-PE intensities at a fixed VUV energy as a function of IR frequency, the respective IR photoion and IR absorption spectra of the corresponding neutral molecule can be measured. Two-color VUV-IR photo-induced Rydberg ionization (PIRI) experiment, in which high-n Rydberg states are prepared by VUV-photoexcitation followed by IR-induced autoionization, has also been demonstrated. Since the IR-VUV-PIE, IR-VUV-PFI-PE, and VUV-IR-PIRI methods do not require the existence of a bound intermediate electronic state in the UV and are generally applicable to all molecules, the development of these two-color photoionization and photoelectron schemes is expected to significantly enhance the scope of VUV spectroscopy and chemistry

  5. Two-color mid-infrared spectroscopy of optically doped semiconductors

    International Nuclear Information System (INIS)

    Forcales, M.; Klik, M.A.J.; Vinh, N.Q.; Phillips, J.; Wells, J-P.R.; Gregorkiewicz, T.

    2003-01-01

    Optical doping is an attractive method to tailor photonic properties of semiconductor matrices for development of solid-state electroluminescent structures. For practical applications, thermal stability of emission obtained from these materials is required. Thermal processes can be conveniently investigated by two-color spectroscopy in the visible and the mid-infrared. Free-electron laser is a versatile high-brilliance source of radiation in the latter spectral range. In this contribution, we briefly review some of the results obtained recently by the two-color spectroscopy with a free-electron laser in different semiconductors optically doped with rare earth and transition metal ions. Effects leading to both enhancement and quenching of emission from optical dopants will be presented. For InP:Yb, Si:Er, and Si:Cu activation of particular optically induced non-radiative recombination paths will be shown. For Si:Er and Si:Ag, observation of a low temperature optical memory effect will be reported

  6. The Infrared Thermometer in School Science: Teaching Physics with Modern Technologies

    Science.gov (United States)

    Girwidz, Raimund; Ireson, Gren

    2011-01-01

    Infrared thermometers measure temperature from a distance, using the infrared radiation emitted by all objects. These so-called non-contact thermometers make a wide variety of temperature measurement and monitoring activities accessible to school-age students. Portable hand-held sensors also enable new or simplified investigations to be carried…

  7. Reliability of an infrared forehead skin thermometer for core temperature measurements

    NARCIS (Netherlands)

    Kistemaker, J.A.; Hartog, E.A. den; Daanen, H.A.M.

    2006-01-01

    The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal

  8. INFRARED TWO-COLOR DIAGRAMS FOR AGB STARS, POST-AGB STARS, AND PLANETARY NEBULAE

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung-Won, E-mail: kwsuh@chungbuk.ac.kr [Department of Astronomy and Space Science, Chungbuk National University, Cheongju-City, 362-763 (Korea, Republic of)

    2015-08-01

    We present various infrared two-color diagrams (2CDs) for asymptotic giant branch (AGB) stars, post-AGB stars, and Planetary Nebulae (PNe) and investigate possible evolutionary tracks. We use catalogs from the available literature for the sample of 4903 AGB stars (3373 O-rich; 1168 C-rich; 362 S-type), 660 post-AGB stars (326 post-AGB; 334 pre-PN), and 1510 PNe in our Galaxy. For each object in the catalog, we cross-identify the IRAS, AKARI, Midcourse Space Experiment, and 2MASS counterparts. The IR 2CDs can provide useful information about the structure and evolution of the dust envelopes as well as the central stars. To find possible evolutionary tracks from AGB stars to PNe on the 2CDs, we investigate spectral evolution of post-AGB stars by making simple but reasonable assumptions on the evolution of the central star and dust shell. We perform radiative transfer model calculations for the detached dust shells around evolving central stars in the post-AGB phase. We find that the theoretical dust shell model tracks using dust opacity functions of amorphous silicate and amorphous carbon roughly coincide with the densely populated observed points of AGB stars, post-AGB stars, and PNe on various IR 2CDs. Even though some discrepancies are inevitable, the end points of the theoretical post-AGB model tracks generally converge in the region of the observed points of PNe on most 2CDs.

  9. Characteristics of infrared thermometers manufactured in Japan and calibration methods for sky radiant emittance

    International Nuclear Information System (INIS)

    Wang, X.; Horiguchi, I.; Machimura, T.

    1993-01-01

    Infrared thermometers to measure surface temperature have been increasingly adopted in recent years. The characteristics of the IR thermometer, however, are not well known.IR thermometers manufactured in Japan systematically adjust for ambient radiation based on the internal temperature of the thermometer. If, therefore, there is a large difference between the internal temperature of the IR thermometer and the apparent temperature associated with the surrounding radiation, a large error will be induced into the measured surface temperature.The purpose of our research was to determine the characteristics and measurement errors of IR thermometers. Experiments were performed with regard to the following items: (1) Measurement errors related to the internal temperature of the IR thermometer. (2) Linearity of the output signal of the IR thermometer. (3) Response of the output signal to changes in the emissivity setting. (4) Effect of sky radiant emittance on the measured surface temperature. (5) Calibration method for the terrestrial surface.The following is a summary of the results: Measurement error is affected by the internal temperature of the IR thermometer. Measurement accuracy is improved with a controlled internal temperature of 20-30°C. The measurement error becomes larger at emissivity settings under 0.7.The measurement error outdoors was not proportional to the downward longwave radiation, but to the sky radiant temperature measured by the IR thermometer. Calibration for sky radiant emittance was improved by using the difference between sky radiant temperature and air temperature.When the surface temperature measured by the infrared thermometer is plotted against the surface temperature measured by thermocouple, the sky radiant emittance error is obtained from the Y intercept. Additionally, the difference between true temperature and output of the IR thermometer for a reference plate was compared to that obtained for vegetation, and the RMS obtained was

  10. Coherent control of D2/H2 dissociative ionization by a mid-infrared two-color laser field

    International Nuclear Information System (INIS)

    Wanie, Vincent; Ibrahim, Heide; Beaulieu, Samuel; Thiré, Nicolas; Schmidt, Bruno E; Légaré, François; Deng, Yunpei; Alnaser, Ali S; Litvinyuk, Igor V; Tong, Xiao-Min

    2016-01-01

    Steering the electrons during an ultrafast photo-induced process in a molecule influences the chemical behavior of the system, opening the door to the control of photochemical reactions and photobiological processes. Electrons can be efficiently localized using a strong laser field with a well-designed temporal shape of the electric component. Consequently, many experiments have been performed with laser sources in the near-infrared region (800 nm) in the interest of studying and enhancing the electron localization. However, due to its limited accessibility, the mid-infrared (MIR) range has barely been investigated, although it allows to efficiently control small molecules and even more complex systems. To push further the manipulation of basic chemical mechanisms, we used a MIR two-color (1800 and 900 nm) laser field to ionize H 2 and D 2 molecules and to steer the remaining electron during the photo-induced dissociation. The study of this prototype reaction led to the simultaneous control of four fragmentation channels. The results are well reproduced by a theoretical model solving the time-dependent Schrödinger equation for the molecular ion, identifying the involved dissociation mechanisms. By varying the relative phase between the two colors, asymmetries (i.e., electron localization selectivity) of up to 65% were obtained, corresponding to enhanced or equivalent levels of control compared to previous experiments. Experimentally easier to implement, the use of a two-color laser field leads to a better electron localization than carrier-envelope phase stabilized pulses and applying the technique in the MIR range reveals more dissociation channels than at 800 nm. (paper)

  11. Use of infrared radiation thermometers for temperature control of plastic and paper webs in electric infrared ovens

    International Nuclear Information System (INIS)

    Jacobson, D.A.

    1985-01-01

    Using infrared radiation thermometers in conjunction with infrared heater systems requires special considerations to ensure that accuracy will be achieved. If the thermometer picks up infrared radiation from the heaters, faulty readings can occur. Two methods are generally employed to eliminate this interference. Sight tubes are used to block infrared rays from entering the sensor lens, and a thermometer is chosen which responds to a different wavelength than that being emitted from the infrared heaters. The main types of electric infrared heaters are: (a) screw-in bulbs (shortwave); (b) evacuated tungsten filament tubes (shortwave); (c) quartz tubes (medium wave); (d) quartz panel heaters (medium wave); (e) Ceramic heaters (medium-long wave); (f) metal sheath heaters (medium-long wave). Positioning of a sensor on a production line is dictated by the product being processed and the desired use of the temperature information. The most common location for a sensor is just after the infrared unit. The pyrometer information can be used for setting up the process, for quality control, for heater failure detection, and for control of the heaters. For wide web application in which uniformity across the web is essential, traversing sensors can be used to scan the web to ensure a uniform heating of the product. This information then can be used to control infrared profiling zones which are positioned across the web. In plastics applications, the thermometer most commonly is positioned also at the exit end of the infrared unit. Control functions are similar to those just listed. In some indexing machines, the plastic is sensed while still in the last index station, and the index an be initiated by the thermometer

  12. Multi-terminal Two-color ZnCdSe/ZnCdMgSe Based Quantum-well Infrared Photodetector

    Science.gov (United States)

    Kaya, Yasin; Ravikumar, Arvind; Chen, Guopeng; Tamargo, Maria C.; Shen, Aidong; Gmachl, Claire

    Target recognition and identification applications benefits from two-color infrared (IR) detectors in the mid and long-wavelength IR regions. Currently, InGaAs/AlGaAs and GaAs/AlGaAs multiple quantum wells (QWs) grown on GaAs substrate are the most commonly used two-color QW IR photodetectors (QWIPs). However, the lattice-mismatch and the buildup of strain limit the number of QWs that can be grown, in turn increasing the dark current noise, and limiting the device detectivity.In this work, we report on two-color QWIPs based on the large conduction band offset (~1.12ev) ZnCdSe/ZnCdMgSe material system lattice matched to InP. QWIPs were designed based on a bound to quasi-bound transition, centered at 4 μm and 7 μm and each QW is repeated 50 times to eliminate the high dark current and a contact layer is inserted between the two stacks of QWs for independent electrical contacts. Wafers are processed into two step rectangular mesas by lithography and wet etching. Experiments showed absorption spectra centered at 4.9 μm and 7.6 μm at 80 K and the full width at half maximums were Δλ / λ = 21 % and Δλ / λ = 23 % , respectively. Current work studies the Johnson and the background noise limited detectivities of these QWIPs. Current address: School of Earth, Energy and Environmental Sciences, Stanford, CA 94305, USA.

  13. Infrared Thermometer: an accurate tool for temperature measurement during renal surgery

    Directory of Open Access Journals (Sweden)

    Giovanni Scala Marchini

    2013-07-01

    Full Text Available Purpose To evaluate infrared thermometer (IRT accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush and 10 without renal cooling (Group 2 - Warm Ischemia. Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT: immediate after clamping (T0, after 2 (T2, 5 (T5 and 10 minutes (T10. Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C. For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C. There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C. For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C. No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio

  14. Use of infrared thermometer technique in irrigation scheduling of pomegranate (Punica granatum L. plant

    Directory of Open Access Journals (Sweden)

    Begüm TEKELİOĞLU

    2017-06-01

    Full Text Available The main objectives of this study are to assess crop water stress index (CWSI and to determine irrigation schedule of pomegranate using infrared thermometer technique. Treatments with three replications were irrigated every three and six days intervals, as much as 0.50 (S1, 0.75 (S2, 1.00 (S3, and 1.25 (S4 of Class A pan evaporation. Additionally, an unirrigated plot was also formed. The equations obtained for non-water stress baseline is Tc-Ta=0.645VPD-4.338. The equation of full water stressed upper baseline obtained from data taken from branches of pomegranate plant cut in different days is given by Tc-Ta= 0.0489VPD+2.8734. According to the results obtained, it is concluded that infrared thermometer can be used for irrigation scheduling of the pomegranate plants in Antalya conditions. When using this technique in Antalya conditions, it is suggested to keep the seasonal mean CWSI value approximately 0.12 and the index value of 0.40 can be used to start the irrigation. Additionally, it is suggested that the amount of irrigation can be determined as much as the amount of evaporation measured until the index value reaches 0.40.

  15. Silicon isotope separation utilizing infrared multiphoton dissociation of Si{sub 2}F{sub 6} irradiated with two-color CO{sub 2} laser light

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Atsushi; Ohba, Hironori; Hashimoto, Masashi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ishii, Takeshi; Ohya, Akio [Nuclear Development Corp., Tokai, Ibaraki (Japan); Arai, Shigeyoshi [Hill Research Co. Ltd., Tokyo (Japan)

    2002-08-01

    Silicon isotope separation has been done by utilizing the Infrared Multiphoton Dissociation (IRMPD) of Si{sub 2}F{sub 6} irradiated with two-color CO{sub 2} laser lights. The two-color excitation method improved the separation efficiency keeping the high enrichment factors. For example, 99.74% of {sup 28}Si was obtained at 49.63% dissociation of Si{sub 2}F{sub 6} after the simultaneous irradiation of 200 pulses with 966.23 cm{sup -1} photons (0.084 J/cm{sup 2}) and 954.55 cm{sup -1} photons (0.658 J/cm{sup 2}), while 2000 pulses were needed to obtain 99.35% of {sup 28}Si at 35.6% dissociation in the case of only one-color irradiation at 954.55 cm{sup -1} (0.97 J/cm{sup 2}). (author)

  16. Silicon isotope separation utilizing infrared multiphoton dissociation of Si2F6 irradiated with two-color CO2 laser light

    International Nuclear Information System (INIS)

    Yokoyama, Atsushi; Ohba, Hironori; Hashimoto, Masashi; Arai, Shigeyoshi

    2002-01-01

    Silicon isotope separation has been done by utilizing the Infrared Multiphoton Dissociation (IRMPD) of Si 2 F 6 irradiated with two-color CO 2 laser lights. The two-color excitation method improved the separation efficiency keeping the high enrichment factors. For example, 99.74% of 28 Si was obtained at 49.63% dissociation of Si 2 F 6 after the simultaneous irradiation of 200 pulses with 966.23 cm -1 photons (0.084 J/cm 2 ) and 954.55 cm -1 photons (0.658 J/cm 2 ), while 2000 pulses were needed to obtain 99.35% of 28 Si at 35.6% dissociation in the case of only one-color irradiation at 954.55 cm -1 (0.97 J/cm 2 ). (author)

  17. Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer.

    Science.gov (United States)

    Kreissl, Hannah; Neiger, Reto

    2015-01-01

    To assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). Prospective single center study. University teaching hospital. Three hundred dogs presented with low, normal, or high body temperatures. Three body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Median body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3°C (range 35.5°C-41.1°C; 95% CI: 38.2-38.4°C) and 37.7°C (35.9°C-40.1°C; 95% CI: 37.7°C-37.9°C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (rRDT = 0.94; rNCIT = 0.82; respectively, P temperature correlated poorly (r = 0.43; P temperature >39.0°C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time. © Veterinary Emergency and Critical Care Society 2015.

  18. Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky

    Science.gov (United States)

    Mims, Forrest M., III; Chambers, Lin H.; Brooks, David R.

    2011-01-01

    A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.

  19. Intraminiband Relaxation In Doped GaAs/AlGaAs Superlattices Studied By Two-Color Infrared Pump-Probe Experiments

    International Nuclear Information System (INIS)

    Wagner, M.; Stehr, D.; Schneider, H.; Helm, M.; Andrews, A. M.; Roch, T.; Strasser, G.

    2010-01-01

    In this work we report on two-color pump-probe measurements to investigate the intraminiband dynamics of doped GaAs/AlGaAs superlattices with different miniband widths smaller or larger than the optical phonon energy. For a miniband with a width larger than the optical phonon energy we found a fast relaxation, independent of the excitation intensity. For narrow minibands this relaxation takes longer and shows a strong temperature and intensity dependence.

  20. Application of an infrared thermometer to the determination of the timing of irrigation

    International Nuclear Information System (INIS)

    Cho, T.; Yano, T.; Nakano, Y.

    1986-01-01

    It is well known that leaf temperature rises with increased crop water stress. This phenomenon is recognized as having the potential to yield information on irrigation scheduling. In this study, infrared thermometry was used to measure crop temperature remotely. The errors in measurements derived from incoming long-wave radiation and leaf emissivity were experimentally evaluated in relation to the reliability of three types of water stress indices using leaf temperature as the parameter. From consecutive measurements of the crop-air temperature difference, obvious changes in daily pattern could be detected as soil water became limited. This result showed that the crop-air temperature difference, although a simple index, can be used in irrigation timing

  1. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.

    Science.gov (United States)

    Kongpanichkul, A; Bunjongpak, S

    2000-09-01

    This study was carried out to assess the accuracy of three devices namely, liquid crystal forehead, digital electronic axillary and infrared tympanic thermometer, using a glass-mercury rectal thermometer as the control. The subjects were two hundred children aged 0-48 months. The mean rectal temperature was 38.0 +/- 0.91 degrees C; forehead, 37.83 +/- 0.94 degrees C; tympanic, 37.77 +/- 0.95 degrees C, and axillary, 37.71 +/- 0.86 degrees C. Compared to the rectal temperature, all values were significantly lower (p < 0.05). Forehead, tympanic and axillary temperature differed from rectal temperature by at least 0.5 degrees C in 33.33 per cent, 23.5 per cent and 31.5 per cent of subjects, and at least 1 degrees C in 22 per cent, 1 per cent and 6 per cent of subjects respectively. Accuracy in detection of fever was 79 per cent for forehead, 85.5 per cent for tympanic and 84 per cent for axillary thermometry. Sensitivity of the three devices was 67-83 per cent in detection of fever and 64-77 per cent in detection of high fever. Tympanic thermometry had the best performance while forehead thermometry had the poorest. After using revised diagnostic threshold temperature by ROC curves, sensitivity of each device improved but accuracy was nearly the same. It is concluded that the three devices are not suitable as a substitute for a glass-mercury rectal thermometer in assessment of fever in infants and young children.

  2. Thermometers: Understand the Options

    Science.gov (United States)

    ... the options Thermometers come in a variety of styles. Understand the different types of thermometers and how ... MA. Fever in infants and children: Pathophysiology and management. http://www.uptodate.com/home. Accessed July 23, ...

  3. Remote sensing of height of a fog layer and temperature of fog droplets using infrared thermometer and meteorological satellite

    International Nuclear Information System (INIS)

    Inoue, K.; Abe, H.

    1998-01-01

    To study meteorological characteristics of cool foggy easterly (Yamase), by which rice production in the Tohoku region was frequently damaged, we measured temperature of the fog layer resulted from Yamase, using infrared thermal indicator and meteorological satellite (HIMAWARI). These temperature data were compared with wet-bulb and dry-bulb temperatures obtained by a ventilated psychrometer. Generally, the temperature of fog droplets estimated from infrared thermal indicator was higher than the wet-bulb temperature by about 0∼1°C. This result indicates clearly that fog droplets were cooled by evaporation on the droplet surface. Under the conditions that the fog layer is homogeneous in liquid water content and fog droplet size distribution, the height of the fog layer can be estimated by the observation of visibility and relative solar radiation flux. (author)

  4. Two-color walking Peregrine solitary waves.

    Science.gov (United States)

    Baronio, Fabio; Chen, Shihua; Mihalache, Dumitru

    2017-09-15

    We study the extreme localization of light, evolving upon a non-zero background, in two-color parametric wave interaction in nonlinear quadratic media. We report the existence of quadratic Peregrine solitary waves, in the presence of significant group-velocity mismatch between the waves (or Poynting vector beam walk-off), in the regime of cascading second-harmonic generation. This finding opens a novel path for the experimental demonstration of extreme rogue waves in ultrafast quadratic nonlinear optics.

  5. Ion thermometers - nuclear reactor applications

    International Nuclear Information System (INIS)

    Rosenkranz, J.; Jakes, D.

    The principle is briefly described of ion thermometers and the effects are reported of radiation on the ion crystal properties. The results show that ion thermometers are applicable for in-core measurements. (J.P.)

  6. Galileo Chain Thermometer

    Science.gov (United States)

    Ucke, C.; Schlichting, H. J.

    2017-01-01

    This relatively rare thermometer has a rather unusual display: lower temperatures are located at the top of the scale, higher ones at the bottom. A sphere on a chain floats in a suitable liquid, sinking at high temperatures when the density of the liquid decreases and rising in the increased density at low temperatures. With reasonable effort and…

  7. The gamma thermometer

    International Nuclear Information System (INIS)

    Beraud, G.; Hourtoulle, F.

    1983-01-01

    The search for a detecting element capable of permanently measuring localised nuclear output which would also be robust straightforward and reliable led EDF to begin development work on a new type of detector in 1976: the gamma thermometer (THG). After briefly summarising the history of the project this article goes on to describe the principle and structure of the equipment used in EDF's PWR reactors. As a result of the extensive test programme carried out it has been possible to qualify analytical and calibration methods together with the thermal and nuclear models. In conclusion, the development prospects and future of such a detecting device are outlined [fr

  8. A portable storage maximum thermometer

    International Nuclear Information System (INIS)

    Fayart, Gerard.

    1976-01-01

    A clinical thermometer storing the voltage corresponding to the maximum temperature in an analog memory is described. End of the measurement is shown by a lamp switch out. The measurement time is shortened by means of a low thermal inertia platinum probe. This portable thermometer is fitted with cell test and calibration system [fr

  9. Probing Xe electronic structure by two-color HHG

    International Nuclear Information System (INIS)

    Faccialà, D; Ciriolo, A G; De Silvestri, S; Devetta, M; Negro, M; Stagira, S; Vozzi, C; Pabst, S; Bruner, B D; Dudovich, N; Soifer, H

    2015-01-01

    The aim of this study is probing the multi-electron behavior in xenon by two-color driven high harmonic generation. By changing the relative polarization of the two colors we were able to study different aspects of the multi-electron response. (paper)

  10. Attosecond pulse trains generated using two color laser fields

    International Nuclear Information System (INIS)

    Mauritsson, J.; Louisiana State University, Baton Rouge, LA; Johnsson, P.; Gustafsson, E.; L'Hullier, A.; Schafer, K.J.; Gaarde, M.B.

    2006-01-01

    Complete test of publication follows. We present the generation of attosecond pulse trains from a superposition of an infrared (IR) laser field and its second harmonic. Our attosecond pulses are synthesized by selecting a number of synchronized harmonics generated in argon. By adding the second harmonic to the driving field the inversion symmetry of generation process is broken and both odd and even harmonics are generated. Consecutive half cycles in the two color field differ beyond the simple sign change that occurs in a one color field and have very different shapes and amplitudes. This sub-cycle structure of the field, which governs the generation of the attosecond pulses, depends strongly on the relative phase and intensity of the two fields, thereby providing additional control over the generation process. The generation of attosecond pulses is frequently described using the semi-classical three step model where an electron is: (1) ionized through tunneling ionization during one half cycle; (2) reaccelerated back towards the ion core by the next half cycle; where it (3) recombines with the ground-state releasing the access energy in a short burst of light. In the two color field the symmetry between the ionizing and reaccelerating field is broken, which leads to two possible scenarios: the electron can either be ionized during a strong half cycle and reaccelerated by a weaker field or vice versa. The periodicity is a full IR cycle in both cases and hence two trains of attosecond pulses are generated which are offset from each other. The generation efficiency, however, is very different for the two cases since it is determined mainly by the electric field strength at the time of tunneling and one of the trains will therefore dominate the other. We investigate experimentally both the spectral and temporal structure of the generated attosecond pulse trains as a function of the relative phase between the two driving fields. We find that for a wide range of

  11. Comparison between tympanic and anal temperature with a clinical infrared ray thermometer in dogs Comparação entre a temperatura timpânica e a temperatura anal usando um termômetro clínico de raio infravermelho em cães

    Directory of Open Access Journals (Sweden)

    G.G.S. Wiedemann

    2006-08-01

    Full Text Available A clinical thermometer of infrared rays was used twice to record consecutively the temperature of the tympanic membrane in each ear and in the anus of 53 dogs. Temperatures did not differ significantly between organs, and were strongly correlated. The anal temperature measurement with an infrared thermometer in dogs is feasible and trustworthy, as well as the thermal checking of tympanic temperature.Utilizou-se um termômetro clínico de emissão de raios infravermelhos para medir, duas vezes consecutivas, a temperatura da membrana timpânica de cada ouvido e duas vezes a temperatura no ânus de 53 cães. Não houve diferença entre as temperaturas quanto ao órgão estudado e a correlação entre as temperaturas foi alta. Em cães, a medida da temperatura anal com o termômetro clínico de emissão de raios infravermelhos é rápida e confiável tanto quanto a da temperatura timpânica.

  12. Young's double-slit interference with two-color biphotons.

    Science.gov (United States)

    Zhang, De-Jian; Wu, Shuang; Li, Hong-Guo; Wang, Hai-Bo; Xiong, Jun; Wang, Kaige

    2017-12-12

    In classical optics, Young's double-slit experiment with colored coherent light gives rise to individual interference fringes for each light frequency, referring to single-photon interference. However, two-photon double-slit interference has been widely studied only for wavelength-degenerate biphoton, known as subwavelength quantum lithography. In this work, we report double-slit interference experiments with two-color biphoton. Different from the degenerate case, the experimental results depend on the measurement methods. From a two-axis coincidence measurement pattern we can extract complete interference information about two colors. The conceptual model provides an intuitional picture of the in-phase and out-of-phase photon correlations and a complete quantum understanding about the which-path information of two colored photons.

  13. Rational choices for the wavelengths of a two color interferometer

    International Nuclear Information System (INIS)

    Jobes, F.C.

    1995-07-01

    If in a two color interferometer for plasma density measurements, the two wavelengths are chosen to have a ratio that is a rational number, and if the signals from each of the wavelengths are multiplied in frequency by the appropriate integer of the rational number and then heterodyned together, the resultant signal will have all effects of component motion nulled out. A phase measurement of this signal will have only plasma density information in it. With CO 2 lasers, it is possible to find suitable wavelength pairs which are close enough to rational numbers to produce an improvement of about 100 in density resolution, compared to standard two color interferometers

  14. Ion thermometers in reactor technology

    International Nuclear Information System (INIS)

    Yakesh, D.; Kott, J.; Strnad, M.

    1980-01-01

    The width of the temperature discontinuity and the thermometric stability of the sensors are constant up to very high flux values. The immediate influence of irradiation is reduced to a decrease in the hysteresis of the conduction curve at the phase transition. When the readings of the ion thermometers are compared with the reading of Chromel-Alumel thermocouples, it is observed that the temperature difference amounts to approximately 7/degree/C in the case of thermocouples placed at the sensor socket; the temperature difference decreases to 2/degree/C in the case of the thermocouple junction situated between the electrodes. The good results obtained in the testing of the ion thermometers in nuclear reactors lead to the conclusion that these temperature sensors are promising for checking thermocouples in the core of nuclear power stations

  15. Frequency modulation of high-order harmonic generation in an orthogonally polarized two-color laser field.

    Science.gov (United States)

    Li, Guicun; Zheng, Yinghui; Ge, Xiaochun; Zeng, Zhinan; Li, Ruxin

    2016-08-08

    We have experimentally investigated the frequency modulation of high-order harmonics in an orthogonally polarized two-color laser field consisting of a mid-infrared 1800nm fundamental pulse and its second harmonic pulse. It is demonstrated that the high harmonic spectra can be fine-tuned as we slightly change the relative delay of the two-color laser pulses. By analyzing the relative frequency shift of each harmonic at different two-color delays, the nonadiabatic spectral shift induced by the rapid variation of the intensity-dependent intrinsic dipole phase can be distinguished from the blueshift induced by the change of the refractive index during self-phase modulation (SPM). Our comprehensive analysis shows that the frequency modulation pattern is a reflection of the average emission time of high-order harmonic generation (HHG), thus offering a simple method to fine-tune the spectra of the harmonics on a sub-cycle time scale.

  16. Thermo-Chromium: A Contactless Optical Molecular Thermometer.

    Science.gov (United States)

    Otto, Sven; Scholz, Norman; Behnke, Thomas; Resch-Genger, Ute; Heinze, Katja

    2017-09-07

    The unparalleled excited-state potential-energy landscape of the chromium(III)-based dye [1] 3+ ([Cr(ddpd) 2 ] 3+ ; ddpd=N,N'-dimethyl-N,N'-dipyridin-2-yl-pyridin-2,6-diamine) enables a strong dual emission in the near infrared region. The temperature dependence of this dual emission allows the use of [1] 3+ as an unprecedented molecular ratiometric thermometer in the 210-373 K temperature range in organic and in aqueous media. Incorporation of [1] 3+ in biocompatible nanocarriers, such as 100 nm-sized polystyrene nanoparticles and solutol micelles, provides nanodimensional thermometers operating under physiological conditions. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Two-colorable graph states with maximal Schmidt measure

    International Nuclear Information System (INIS)

    Severini, Simone

    2006-01-01

    The Schmidt measure was introduced by Eisert and Briegel for quantifying the degree of entanglement of multipartite quantum systems [J. Eisert, H.-J. Briegel, Phys. Rev. A 64 (2001) 22306]. For two-colorable graph states, the Schmidt measure is related to the spectrum of the associated graph. We observe that almost all two-colorable graph states have maximal Schmidt measure and we construct specific examples. By making appeal to a result of Ehrenfeucht et al. [A. Ehrenfeucht, T. Harju, G. Rozenberg, Discrete Math. 278 (2004) 45], we point out that the graph operations called local complementation and switching form a transitive group acting on the set of all graph states of a given dimension

  18. Tunneling ionization and harmonic generation in two-color fields

    International Nuclear Information System (INIS)

    Kondo, K.; Kobayashi, Y.; Sagisaka, A.; Nabekawa, Y.; Watanabe, S.

    1996-01-01

    Tunneling ionization and harmonic generation in two-color fields were studied with a fundamental beam (ω) and its harmonics (2ω,3ω), which were generated by a 100-fs Ti:sapphire laser. Ion yields of atoms and molecules were successfully controlled by means of a change in the relative phase between ω and 3ω pulses. Two-color interference was clearly observed in photoelectron spectra and harmonic spectra. In the ω endash 2ω field even-order harmonics were observed in which the intensity was almost equal to that of the odd harmonics because of an asymmetric optical field. These results were compared with the quasi-static model for ionization and with the quantum theory for harmonic generation. copyright 1996 Optical Society of America

  19. Two-color studies of autoionizing states of small molecules

    International Nuclear Information System (INIS)

    Pratt, S.T.; Dehmer, P.M.; Dehmer, J.L.; Tomkins, F.S.; O'Halloran, M.A.

    1989-01-01

    Two-color, resonantly enhanced multiphoton ionization is proving to be a valuable technique for the study of autoionizing states of small molecules. In this talk, results obtained by combining REMPI, photoelectron spectroscopy, and mass spectrometry will be discussed and will be illustrated by examples from our recent studies of rotational and vibrational autoionization in molecular hydrogen and rotational autoionization in nitric oxide. 2 refs., 1 fig

  20. Design study for a two-color beta measurement system

    Science.gov (United States)

    1982-01-01

    Design analysis of the beam splitter combined two color beta system is presented. Conventional and dichroic beam splitters are discussed. Design analysis of the beta system employing two beams with focusing at separate points is presented. Alterations and basic parameters of the two beam system are discussed. Alterations in the focus of the initial laser and the returning beams are also discussed. Heterodyne efficiencies for the on axis and off axis reflected radiation are included.

  1. Enhanced hole boring with two-color relativistic laser pulses in the fast ignition scheme

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Changhai; Tian, Ye; Li, Wentao; Wang, Wentao; Zhang, Zhijun; Qi, Rong; Wang, Cheng [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Deng, Aihua, E-mail: aihuadeng1985@gmail.com [Department of Physics and Astronomy, University of California, Los Angeles, California 90095 (United States); Liu, Jiansheng, E-mail: michaeljs-liu@siom.ac.cn [State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Collaborative Innovation Center of IFSA (CICIFSA), Shanghai Jiao Tong University, Shanghai 200240 (China)

    2016-08-15

    A scheme of using two-color laser pulses for hole boring into overdense plasma as well as energy transfer into electron and ion beams has been studied using particle-in-cell simulations. Following an ultra-short ultra-intense hole-boring laser pulse with a short central wavelength in extreme ultra-violet range, the main infrared driving laser pulse can be guided in the hollow channel preformed by the former laser and propagate much deeper into an overdense plasma, as compared to the case using the infrared laser only. In addition to efficiently transferring the main driving laser energy into energetic electrons and ions generation deep inside the overdense plasma, the ion beam divergence can be greatly reduced. The results might be beneficial for the fast ignition concept of inertial confinement fusion.

  2. Very high temperature ultrasonic thermometer

    International Nuclear Information System (INIS)

    Jorzik, E.

    1983-01-01

    An ultrasonic thermometer comprises an electric pulse transducer head, a pulse transmission line, a notched sensor wire attached to and extending along the axis of said transmission line and a sheath enclosing the transmission line and the sensor wire, a portion of the interior face of the sheath being covered by a stuffing material along at least the length of the notched part of the sensor wire, such that contact between the sensor wire and the stuffing material does not substantially give rise to reflection of an ultrasonic pulse at the point of contact. (author)

  3. Spinor Slow Light and Two-Color Qubits

    Science.gov (United States)

    Yu, Ite; Lee, Meng-Jung; Ruseckas, Julius; Lee, Chin-Yuan; Kudriasov, Viaceslav; Chang, Kao-Fang; Cho, Hung-Wen; Juzeliunas, Gediminas; Yu, Ite A.

    2015-05-01

    We report the first experimental demonstration of two-component or spinor slow light (SSL) using a double tripod (DT) atom-light coupling scheme. The scheme involves three atomic ground states coupled to two excited states by six light fields. The oscillation due to the interaction between the two components was observed. SSL can be used to achieve high conversion efficiencies in the sum frequency generation and is a better method than the widely-used double- Λ scheme. On the basis of the stored light, our data showed that the DT scheme behaves like the two outcomes of an interferometer enabling precision measurements of frequency detuning. Furthermore, the single-photon SSL can be considered as the qubit with the superposition state of two frequency modes or, simply, as the two-color qubit. We experimentally demonstrated a possible application of the DT scheme as quantum memory/rotator for the two-color qubit. This work opens up a new direction in the EIT/slow light research. yu@phys.nthu.edu.tw

  4. Two color photodetector using an asymmetric quantum well structure

    OpenAIRE

    Lantz, Kevin R.

    2002-01-01

    Approved for public release; distribution is unlimited The past twenty years have seen an explosion in the realm of infrared detection technology fueled by improvements in III-V semiconductor technology and by new semiconductor growth methods. One of the fastest growing areas of this research involves the use of bandgap engineering in order to create artificial quantum wells for use in Quantum Well Infrared Photodetectors (QWIPs). QWIPs have an advantage over other infrared detectors such ...

  5. Ar 3p photoelectron sideband spectra in two-color XUV + NIR laser fields

    Science.gov (United States)

    Minemoto, Shinichirou; Shimada, Hiroyuki; Komatsu, Kazma; Komatsubara, Wataru; Majima, Takuya; Mizuno, Tomoya; Owada, Shigeki; Sakai, Hirofumi; Togashi, Tadashi; Yoshida, Shintaro; Yabashi, Makina; Yagishita, Akira

    2018-04-01

    We performed photoelectron spectroscopy using femtosecond XUV pulses from a free-electron laser and femtosecond near-infrared pulses from a synchronized laser, and succeeded in measuring Ar 3p photoelectron sideband spectra due to the two-color above-threshold ionization. In our calculations of the first-order time-dependent perturbation theoretical model based on the strong field approximation, the photoelectron sideband spectra and their angular distributions are well reproduced by considering the timing jitter between the XUV and the NIR pulses, showing that the timing jitter in our experiments was distributed over the width of {1.0}+0.4-0.2 ps. The present approach can be used as a method to evaluate the timing jitter inevitable in FEL experiments.

  6. Cryogenic Thermometer Calibration Facility at CERN

    CERN Document Server

    Balle, C; Thermeau, J P

    1998-01-01

    A cryogenic thermometer calibration facility has been designed and is being commissioned in preparation for the very stringent requirements on the temperature control of the LHC superconducting magnets. The temperature is traceable in the 1.5 to 30 K range to standards maintained in a national metrological laboratory by using a set of Rhodium-Iron temperature sensors of metrological quality. The calibration facility is designed for calibrating simultaneously 60 industrial cryogenic thermometers in the 1.5 K to 300 K temperature range, a thermometer being a device that includes both a temperature sensor and the wires heat-intercept. The thermometers can be calibrated in good and degraded vacuum or immersed in the surrounding fluid and at different Joule self-heating conditions that match those imposed by signal conditioners used in large cryogenic machinery. The calibration facility can be operated in an automatic mode and all the control and safety routines are handled by a Programmable Logic Controller (PLC)...

  7. Thermal Conductivity and Liquid Crystal Thermometers.

    Science.gov (United States)

    Edge, R. D., Ed.

    1993-01-01

    Describes using stock liquid crystal postcards as inexpensive classroom thermometers. Also suggests using these postcards as a good visual temperature indicator for classroom demonstrations such as temperature gradients. One such activity is provided. (MVL)

  8. A silicon nanowire heater and thermometer

    Science.gov (United States)

    Zhao, Xingyan; Dan, Yaping

    2017-07-01

    In the thermal conductivity measurements of thermoelectric materials, heaters and thermometers made of the same semiconducting materials under test, forming a homogeneous system, will significantly simplify fabrication and integration. In this work, we demonstrate a high-performance heater and thermometer made of single silicon nanowires (SiNWs). The SiNWs are patterned out of a silicon-on-insulator wafer by CMOS-compatible fabrication processes. The electronic properties of the nanowires are characterized by four-probe and low temperature Hall effect measurements. The I-V curves of the nanowires are linear at small voltage bias. The temperature dependence of the nanowire resistance allows the nanowire to be used as a highly sensitive thermometer. At high voltage bias, the I-V curves of the nanowire become nonlinear due to the effect of Joule heating. The temperature of the nanowire heater can be accurately monitored by the nanowire itself as a thermometer.

  9. Silicon photonic thermometer operating on multiple polarizations

    DEFF Research Database (Denmark)

    Guan, Xiaowei; Wang, Xiaoyan; Frandsen, Lars Hagedorn

    2016-01-01

    A silicon photonics optical thermometer simultaneously operating on the multiple polarizations is designed and experimentally demonstrated. Measured sensitivities are 86pm/°C and 48pm/°C for the transverse-electric and transverse-magnetic polarizations, respectively.......A silicon photonics optical thermometer simultaneously operating on the multiple polarizations is designed and experimentally demonstrated. Measured sensitivities are 86pm/°C and 48pm/°C for the transverse-electric and transverse-magnetic polarizations, respectively....

  10. Two-color lattice QCD with staggered quarks

    Energy Technology Data Exchange (ETDEWEB)

    Scheffler, David

    2015-07-20

    The study of quantum chromodynamics (QCD) at finite temperature and density provides important contributions to the understanding of strong-interaction matter as it is present e.g. in nuclear matter and in neutron stars or as produced in heavy-ion collision experiments. Lattice QCD is a non-perturbative approach, where equations of motion for quarks and gluons are discretized on a finite space-time lattice. The method successfully describes the behavior of QCD in the vacuum and at finite temperature, however it cannot be applied to finite baryon density due to the fermion sign problem. Various QCD-like theories, that offer to draw conclusions about QCD, allow simulations also at finite densities. In this work we investigate two-color QCD as a popular example of a QCD-like theory free from the sign problem with methods from lattice gauge theory. For the generation of gauge configurations with two dynamical quark flavors in the staggered formalism with the ''rooting trick'' we apply the Rational Hybrid Monte Carlo (RHMC) algorithm. We carry out essential preparatory work for future simulations at finite density. As a start, we concentrate on the calculation of the effective potential for the Polyakov loop, which is an order parameter for the confinement-deconfinement transition, in dependence of the temperature and quark mass. It serves as an important input for effective models of QCD. We obtain the effective potential via the histogram method from local distributions of the Polyakov loop. To study the influence of dynamical quarks on gluonic observables, the simulations are performed with large quark masses and are compared to calculations in the pure gauge theory. In the second part of the thesis we examine aspects of the chiral phase transition along the temperature axis. The symmetry group of chiral symmetry in two-color QCD is enlarged to SU(2N{sub f}). Discretized two-color QCD in the staggered formalism exhibits a chiral symmetry breaking

  11. Study on two-color planar laser induced fluorescence thermometry

    International Nuclear Information System (INIS)

    Li Shaodan; Tan Sichao; Gao Puzhen; Lin Yuansheng

    2014-01-01

    Many of the convection heat transfer process are involved in the research of nuclear reactor thermal hydraulics. To experimentally determine the variation of the temperature field in those processes is important for the design and safety operation of the nuclear reactor. The application of the two-color planar laser induced fluorescence (PLIF) in the measurements of fluid temperature distribution is discussed in the paper. The laser dyes used here is rhodamine B (RhB) with negative temperature coefficient and fluorescein 27 (F127) with positive temperature coefficient. The beam of the laser light is adjusted to laser sheet by using the lens group. The fluid with dyes is excited by this laser sheet in a specific plane and temperature dependent fluorescence is released. The temperature field of the plane can be determined through the intensity information. Some technical aspects encountered in the application of the two-laser PLIF are discussed in the paper, such as the spectra characteristic of the dyes and the separation of the spectra. The calibration temperature is higher than the water saturation temperature (at atmosphere pressure). (authors)

  12. Finite density two color chiral perturbation theory revisited

    Science.gov (United States)

    Adhikari, Prabal; Beleznay, Soma B.; Mannarelli, Massimo

    2018-06-01

    We revisit two-color, two-flavor chiral perturbation theory at finite isospin and baryon density. We investigate the phase diagram obtained varying the isospin and the baryon chemical potentials, focusing on the phase transition occurring when the two chemical potentials are equal and exceed the pion mass (which is degenerate with the diquark mass). In this case, there is a change in the order parameter of the theory that does not lend itself to the standard picture of first order transitions. We explore this phase transition both within a Ginzburg-Landau framework valid in a limited parameter space and then by inspecting the full chiral Lagrangian in all the accessible parameter space. Across the phase transition between the two broken phases the order parameter becomes an SU(2) doublet, with the ground state fixing the expectation value of the sum of the magnitude squared of the pion and the diquark fields. Furthermore, we find that the Lagrangian at equal chemical potentials is invariant under global SU(2) transformations and construct the effective Lagrangian of the three Goldstone degrees of freedom by integrating out the radial fluctuations.

  13. Design of a Toolbox of RNA Thermometers.

    Science.gov (United States)

    Sen, Shaunak; Apurva, Divyansh; Satija, Rohit; Siegal, Dan; Murray, Richard M

    2017-08-18

    Biomolecular temperature sensors can be used for efficient control of large-volume bioreactors, for spatiotemporal imaging and control of gene expression, and to engineer robustness to temperature in biomolecular circuit design. Although RNA-based sensors, called "thermometers", have been investigated in both natural and synthetic contexts, an important challenge is to design diverse responses to temperature differing in sensitivity and threshold. We address this issue by constructing a library of RNA thermometers based on thermodynamic computations and experimentally measuring their activities in cell-free biomolecular "breadboards". Using free energies of the minimum free energy structures as well as melt profile computations, we estimated that a diverse set of temperature responses were possible. We experimentally found a wide range of responses to temperature in the range 29-37 °C with fold-changes varying over 3-fold around the starting thermometer. The sensitivities of these responses ranged over 10-fold around the starting thermometer. We correlated these measurements with computational expectations, finding that although there was no strong correlation for the individual thermometers, overall trends of diversity, fold-changes, and sensitivities were similar. These results present a toolbox of RNA-based circuit elements with diverse temperature responses.

  14. Two-color above-threshold ionization of atoms and ions in XUV Bessel beams and intense laser light

    Science.gov (United States)

    Seipt, D.; Müller, R. A.; Surzhykov, A.; Fritzsche, S.

    2016-11-01

    The two-color above-threshold ionization (ATI) of atoms and ions is investigated for a vortex Bessel beam in the presence of a strong near-infrared (NIR) light field. While the photoionization is caused by the photons from the weak but extreme ultraviolet (XUV) vortex Bessel beam, the energy and angular distribution of the photoelectrons and their sideband structure are affected by the plane-wave NIR field. We here explore the energy spectra and angular emission of the photoelectrons in such two-color fields as a function of the size and location of the target atoms with regard to the beam axis. In addition, analog to the circular dichroism in typical two-color ATI experiments with circularly polarized light, we define and discuss seven different dichroism signals for such vortex Bessel beams that arise from the various combinations of the orbital and spin angular momenta of the two light fields. For localized targets, it is found that these dichroism signals strongly depend on the size and position of the atoms relative to the beam. For macroscopically extended targets, in contrast, three of these dichroism signals tend to zero, while the other four just coincide with the standard circular dichroism, similar as for Bessel beams with a small opening angle. Detailed computations of the dichroism are performed and discussed for the 4 s valence-shell photoionization of Ca+ ions.

  15. 21 CFR 880.2920 - Clinical mercury thermometer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical mercury thermometer. 880.2920 Section 880... Devices § 880.2920 Clinical mercury thermometer. (a) Identification. A clinical mercury thermometer is a... mercury. (b) Classification. Class II (special controls). The device is exempt from the premarket...

  16. New blackbody standard for the evaluation and calibration of tympanic ear thermometers at the NPL, United Kingdom

    Science.gov (United States)

    McEvoy, Helen C.; Simpson, Robert; Machin, Graham

    2004-04-01

    The use of infrared tympanic thermometers for monitoring patient health is widespread. However, studies into the performance of these thermometers have questioned their accuracy and repeatability. To give users confidence in these devices, and to provide credibility in the measurements, it is necessary for them to be tested using an accredited, standard blackbody source, with a calibration traceable to the International Temperature Scale of 1990 (ITS-90). To address this need the National Physical Laboratory (NPL), UK, has recently set up a primary ear thermometer calibration (PET-C) source for the evaluation and calibration of tympanic (ear) thermometers over the range from 15 °C to 45 °C. The overall uncertainty of the PET-C source is estimated to be +/- 0.04 °C at k = 2. The PET-C source meets the requirements of the European Standard EN 12470-5: 2003 Clinical thermometers. It consists of a high emissivity blackbody cavity immersed in a bath of stirred liquid. The temperature of the blackbody is determined using an ITS-90 calibrated platinum resistance thermometer inserted close to the rear of the cavity. The temperature stability and uniformity of the PET-C source was evaluated and its performance validated. This paper provides a description of the PET-C along with the results of the validation measurements. To further confirm the performance of the PET-C source it was compared to the standard ear thermometer calibration sources of the National Metrology Institute of Japan (NMIJ), Japan and the Physikalisch-Technische Bundesanstalt (PTB), Germany. The results of this comparison will also be briefly discussed. The PET-C source extends the capability for testing ear thermometers offered by the NPL body temperature fixed-point source, described previously. An update on the progress with the commercialisation of the fixed-point source will be given.

  17. Process for constructing a gamma thermometer

    International Nuclear Information System (INIS)

    Barbet, M.J.P.; Cohen, B.S.; Robillard, M.

    1982-01-01

    A process is described for constructing a gamma thermometer having a substance absorbing the radiation and a set of thermocouples for measuring the local power in a fuel assembly of a nuclear reactor. A claim is particularly made for the preparation of the tube containing it and for its filling with an inert gas [fr

  18. Spectrally resolved measurements of the terahertz beam profile generated from a two-color air plasma

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Zalkovskij, Maksim; Strikwerda, Andrew

    2014-01-01

    Using a THz camera and THz bandpass filters, we measure the frequency - resolved beam profile emitted from a two - color air plasma. We observe a frequency - independent emission angle from the plasma .......Using a THz camera and THz bandpass filters, we measure the frequency - resolved beam profile emitted from a two - color air plasma. We observe a frequency - independent emission angle from the plasma ....

  19. On Two Color and CCD Methods for the Determination of Astronomic Position.

    Science.gov (United States)

    1986-03-14

    INTRODUCTION .................................... 2 A. Astroposition Objectives As Related to Two-Color Refractometry .................. 2 B. Results...value for the astronomic longitude and latitude.-_ A. Astroposition Objectives As Related to Two-Color Refractometry The long term objectives consist...The interior of the box was divided into 4 bays containing the telescope, the refractometry optics, the power supplies and the refralctometry

  20. Development of two color laser diagnostics for the ITER poloidal polarimeter.

    Science.gov (United States)

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2010-10-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  1. Development of two color laser diagnostics for the ITER poloidal polarimeter

    International Nuclear Information System (INIS)

    Kawahata, K.; Akiyama, T.; Tanaka, K.; Nakayama, K.; Okajima, S.

    2010-01-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH 3 OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  2. Intensity dependence of nonsequential double ionization of helium in IR+XUV two-color laser fields

    International Nuclear Information System (INIS)

    Jin, Facheng; Wang, Bingbing; Chen, Jing; Yang, Yujun; Yan, Zong-Chao

    2016-01-01

    By applying the frequency-domain theory, we investigate the dependence of momentum spectra on laser intensity in a nonsequential double ionization (NSDI) process of helium in infrared (IR) and extreme ultraviolet (XUV) two-color laser fields. We find that the two-color laser fields play distinct roles in an NSDI process, where the IR laser field mainly determines the width of each band, and the XUV laser field mainly plays a role on the NSDI probability. Furthermore, an NSDI process can be decoupled into a two-step process: an above-threshold ionization (ATI), followed by a laser-assisted collision (LAC). It is found that, the IR laser field is responsible for broadening the peak in the ATI process and providing additional momenta to the two ionized electrons in the LAC process; while the XUV laser field plays a crucial role on the strength of the spectrum in the ATI process, and influences the radii of orbits in momentum space in the LAC process. (paper)

  3. Infrared

    Science.gov (United States)

    Vollmer, M.

    2013-11-01

    'Infrared' is a very wide field in physics and the natural sciences which has evolved enormously in recent decades. It all started in 1800 with Friedrich Wilhelm Herschel's discovery of infrared (IR) radiation within the spectrum of the Sun. Thereafter a few important milestones towards widespread use of IR were the quantitative description of the laws of blackbody radiation by Max Planck in 1900; the application of quantum mechanics to understand the rotational-vibrational spectra of molecules starting in the first half of the 20th century; and the revolution in source and detector technologies due to micro-technological breakthroughs towards the end of the 20th century. This has led to much high-quality and sophisticated equipment in terms of detectors, sources and instruments in the IR spectral range, with a multitude of different applications in science and technology. This special issue tries to focus on a few aspects of the astonishing variety of different disciplines, techniques and applications concerning the general topic of infrared radiation. Part of the content is based upon an interdisciplinary international conference on the topic held in 2012 in Bad Honnef, Germany. It is hoped that the information provided here may be useful for teaching the general topic of electromagnetic radiation in the IR spectral range in advanced university courses for postgraduate students. In the most general terms, the infrared spectral range is defined to extend from wavelengths of 780 nm (upper range of the VIS spectral range) up to wavelengths of 1 mm (lower end of the microwave range). Various definitions of near, middle and far infrared or thermal infrared, and lately terahertz frequencies, are used, which all fall in this range. These special definitions often depend on the scientific field of research. Unfortunately, many of these fields seem to have developed independently from neighbouring disciplines, although they deal with very similar topics in respect of the

  4. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

    International Nuclear Information System (INIS)

    Fu Tairan; Cheng Xiaofang; Yang Zangjian

    2008-01-01

    We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution

  5. A semiclassical approach for two-color four-mode solid-state superfluorescence

    International Nuclear Information System (INIS)

    Lambruschini, C.L.P.

    1991-05-01

    A model for multilevel superfluorescence is presented. By using a parametric solution of this model we explain basic features in the two-color solid-state superfluorescence experiments of Florian, Schwan and Schmid. (author). 23 refs

  6. Quantum manipulation of two-color stationary light: Quantum wavelength conversion

    International Nuclear Information System (INIS)

    Moiseev, S. A.; Ham, B. S.

    2006-01-01

    We present a quantum manipulation of a traveling light pulse using electromagnetically induced transparency-based slow light phenomenon for the generation of two-color stationary light. We theoretically discuss the two-color stationary light for the quantum wavelength conversion process in terms of pulse area, energy transfer, and propagation directions. The condition of the two-color stationary light pulse generation has been found and the quantum light dynamics has been studied analytically in the adiabatic limit. The quantum frequency conversion rate of the traveling light is dependent on the spatial spreading of the two-color stationary light pulse and can be near unity in an optically dense medium for the optimal frequencies of the control laser fields

  7. Controlling mercury spills in laboratories with a thermometer exchange program

    Energy Technology Data Exchange (ETDEWEB)

    McLouth, Lawrence D.

    2002-03-25

    This paper presents a case for replacing mercury thermometers with their organic-liquid-filled counterparts. A review of liquid-in glass-thermometers is given. In addition, a brief summary of mercury's health effects and exposure limits is presented. Spill cleanup methods and some lessons learned from our experience are offered as well. Finally, an overview of the mercury thermometer exchange program developed at Lawrence Berkeley National Laboratory is presented.

  8. The constitution of the heat density of a gamma thermometer

    International Nuclear Information System (INIS)

    Hantouche, C.

    1984-01-01

    This paper's aim is to present the nuclear transfer function of the signal of the γ thermometer used in a PWR reactor. The nuclear transfer function between the linear nuclear power and the γ thermometer heat density has been established. The corresponding computation code has been built up. The results concerning the environment behaviour of the γ thermometer, the heat density axial and radial repartitions, the control rods and the grids' influences are presented and discussed. (orig.)

  9. A gas thermometer for vapor pressure measurements

    Science.gov (United States)

    Rusin, A. D.

    2008-08-01

    The pressure of an inert gas over the range 400 1000 K was measured on a tensimetric unit with a quartz membrane pressure gauge of enhanced sensitivity. It was shown that a reactor with a membrane null gauge could be used as a gas thermometer. The experimental confidence pressure and temperature intervals were 0.07 torr and 0.1 K at a significance level of 0.05. A Pt-Pt/10% Rh thermocouple was calibrated; the results were approximated by a polynomial of degree five. The error in temperature calculations was 0.25 K.

  10. Influence of Thermal Cycling on Cryogenic Thermometers

    CERN Document Server

    Balle, C; Rieubland, Jean Michel; Suraci, A; Togny, F; Vauthier, N

    1999-01-01

    The stringent requirements on temperature control of the superconducting magnets for the Large Hadron Collider (LHC), impose that the cryogenic temperature sensors meet compelling demands such as long-term stability, radiation hardness, readout accuracy better than 5 mK at 1.8 K and compatibility with industrial control equipment. This paper presents the results concerning long-term stability of resistance temperature sensors submitted to cryogenic thermal cycles. For this task a simple test facility has been designed, constructed and put into operation for cycling simultaneously 115 cryogenic thermometers between 300 K and 4.2 K. A thermal cycle is set to last 71/4 hours: 3 hours for either cooling down or warming up the sensors and 1 respectively 1/4 hour at steady temperature conditions at each end of the temperature cycle. A Programmable Logic Controller (PLC) drives automatically this operation by reading 2 thermometers and actuating on 3 valves and 1 heater. The first thermal cycle was accomplished in a...

  11. Calibration of Cryogenic Thermometers for the LHC

    CERN Document Server

    Balle, Ch; Vauthier, N; Thermeau, JP

    2008-01-01

    6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In the framework of a special contribution, IPN (Institut de Physique Nucléaire) in Orsay, France built and operated a calibration facility with a throughput of 80 thermometers per week. After reception from the manufacturer, the thermometer is first assembled onto a support specific to the measurement environment, and then thermally cycled ten times and calibrated at least once from 1.6 to 300 K. The procedure for each of these interventions includes various measurements and the acquired data is recorded in an ORACLE®-database. Furthermore random calibrations on some samples are executed at CERN to crosscheck the coherence between the approximation data obtained by both IPN and CERN. In the range of 1.5 K to 30 K...

  12. Thermodynamics and historical relevance of a jetting thermometer made of Chinese zisha ceramic

    Science.gov (United States)

    Lee, Vincent; Attinger, Daniel

    2016-07-01

    Following a recent trend of scientific studies on artwork, we study here the thermodynamics of a thermometer made of zisha ceramic, related to the Chinese tea culture. The thermometer represents a boy who “urinates” shortly after hot water is poured onto his head. Long jetting distance is said to indicate that the water temperature is hot enough to brew tea. Here, a thermodynamic model describes the jetting phenomenon of that pee-pee boy. The study demonstrates how thermal expansion of an interior air pocket causes jetting. A thermodynamic potential is shown to define maximum jetting velocity. Seven optimization criteria to maximize jetting distance are provided, including two dimensionless numbers. Predicted jetting distances, jet durations, and temperatures agree very well with infrared and optical measurements. Specifically, the study confirms that jetting distances are sensitive enough to measure water temperature in the context of tea brewing. Optimization results show that longer jets are produced by large individuals, with low body mass index, with a boyhood of medium size inclined at an angle π/4. The study ends by considering the possibility that ceramic jetting artifacts like the pee-pee boy might have been the first thermometers known to mankind, before Galileo Galilei’s thermoscope.

  13. Two-color quark matter: U(1)A restoration, superfluidity, and quarkyonic phase

    International Nuclear Information System (INIS)

    Brauner, Tomas; Fukushima, Kenji; Hidaka, Yoshimasa

    2009-01-01

    We discuss the phase structure of quantum chromodynamics (QCD) with two colors and two flavors of light quarks. This is motivated by the increasing interest in the QCD phase diagram as follows: (1) The QCD critical point search has been under intensive dispute and its location and existence suffer from uncertainty of effective U(1) A symmetry restoration. (2) A new phase called quarkyonic matter is drawing theoretical and experimental attention but it is not clear whether it can coexist with diquark condensation. We point out that two-color QCD is nontrivial enough to contain essential ingredients for (1) and (2) both, and most importantly, is a system without the sign problem in numerical simulations on the lattice. We adopt the two-flavor Nambu-Jona-Lasinio model extended with the two-color Polyakov loop and make quantitative predictions that can be tested by lattice simulations.

  14. Inkjet printing the three organic functional layers of two-colored organic light emitting diodes

    International Nuclear Information System (INIS)

    Coenen, Michiel J.J.; Slaats, Thijs M.W.L.; Eggenhuisen, Tamara M.; Groen, Pim

    2015-01-01

    Inkjet printing allows for the roll-2-roll fabrication of organic electronic devices at an industrial scale. In this paper we demonstrate the fabrication of two-colored organic light emitting diodes (OLEDs) in which three adjacent organic device layers were inkjet printed from halogen free inks. The resulting devices demonstrate the possibilities offered by this technique for the fabrication of OLEDs for signage and personalized electronics. - Highlights: • Two-colored organic light emitting diodes with 3 inkjet printed device layers were fabricated. • All materials were printed from halogen free inks. • Inkjet printing of emissive materials is suitable for signage applications

  15. Investigation of dynamic of unconsolidated materials using two-color digital holography

    Directory of Open Access Journals (Sweden)

    Boileau J.-P.

    2010-06-01

    Full Text Available The paper presents a two-color digital holographic interferometer. The set-up is devoted to the study of the fundamental dynamic of unconsolidated materials. Optical configuration and algorithms to recover the optical phase of two-color digitally encoded holograms are described. The method is based on a spatial-color-multiplexing scheme in which holographic reconstruction is performed using adapted wavelength zero-padding and reconstructing distance. Experimental results are presented in the case of granular media excited in the frequency range 400Hz-3000Hz and exhibits the 3D movement.

  16. The application of infrared thermometric technology in the nuclear industry

    International Nuclear Information System (INIS)

    Wang Wenjin

    1992-04-01

    In the process of bituminization of low level waste liquid, to measure the surface temperature of a moving barrel filled with waste liquid and bitumen is essential. Thus, a special infrared thermometer is developed. The property of radiation resistance for the lithium tantalate prober which is a main part of the thermometer was carefully tested. The test results show that in the nuclear industry the infrared thermometric technology is applicable

  17. Controlling nonsequential double ionization of Ne with parallel-polarized two-color laser pulses.

    Science.gov (United States)

    Luo, Siqiang; Ma, Xiaomeng; Xie, Hui; Li, Min; Zhou, Yueming; Cao, Wei; Lu, Peixiang

    2018-05-14

    We measure the recoil-ion momentum distributions from nonsequential double ionization of Ne by two-color laser pulses consisting of a strong 800-nm field and a weak 400-nm field with parallel polarizations. The ion momentum spectra show pronounced asymmetries in the emission direction, which depend sensitively on the relative phase of the two-color components. Moreover, the peak of the doubly charged ion momentum distribution shifts gradually with the relative phase. The shifted range is much larger than the maximal vector potential of the 400-nm laser field. Those features are well recaptured by a semiclassical model. Through analyzing the correlated electron dynamics, we found that the energy sharing between the two electrons is extremely unequal at the instant of recollison. We further show that the shift of the ion momentum corresponds to the change of the recollision time in the two-color laser field. By tuning the relative phase of the two-color components, the recollision time is controlled with attosecond precision.

  18. Extended analysis of benchmark datasets for Agilent two-color microarrays

    Directory of Open Access Journals (Sweden)

    Kerr Kathleen F

    2007-10-01

    Full Text Available Abstract Background As part of its broad and ambitious mission, the MicroArray Quality Control (MAQC project reported the results of experiments using External RNA Controls (ERCs on five microarray platforms. For most platforms, several different methods of data processing were considered. However, there was no similar consideration of different methods for processing the data from the Agilent two-color platform. While this omission is understandable given the scale of the project, it can create the false impression that there is consensus about the best way to process Agilent two-color data. It is also important to consider whether ERCs are representative of all the probes on a microarray. Results A comparison of different methods of processing Agilent two-color data shows substantial differences among methods for low-intensity genes. The sensitivity and specificity for detecting differentially expressed genes varies substantially for different methods. Analysis also reveals that the ERCs in the MAQC data only span the upper half of the intensity range, and therefore cannot be representative of all genes on the microarray. Conclusion Although ERCs demonstrate good agreement between observed and expected log-ratios on the Agilent two-color platform, such an analysis is incomplete. Simple loess normalization outperformed data processing with Agilent's Feature Extraction software for accurate identification of differentially expressed genes. Results from studies using ERCs should not be over-generalized when ERCs are not representative of all probes on a microarray.

  19. Long-range predissociation in two-color photoassociation of ultracold Na atoms

    NARCIS (Netherlands)

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.

    1997-01-01

    We report two-color photo-associative ionization of sodium in a Magneto-Optical Trap. The experimental results yield information on both singly and doubly excited states. We find that the highest bound vibrational levels (v > 20) of the singly-excited 0^- g state predissociate into the 3²P3/2

  20. Effects of a static electric field on two-color photoassociation between different atoms

    International Nuclear Information System (INIS)

    Chakraborty, Debashree; Deb, Bimalendu

    2014-01-01

    We study non-perturbative effects of a static electric field on two-color photoassociation of different atoms. A static electric field induces anisotropy in scattering between two different atoms and hybridizes field-free rotational states of heteronuclear dimers or polar molecules. In a previous paper [D. Chakraborty et al., J. Phys. B 44, 095201 (2011)], the effects of a static electric field on one-color photoassociation between different atoms has been described through field-modified ground-state scattering states, neglecting electric field effects on heteronuclear diatomic bound states. To study the effects of a static electric field on heteronuclear bound states, and the resulting influence on Raman-type two-color photoassociation between different atoms in the presence of a static electric field, we develop a non-perturbative numerical method to calculate static electric field-dressed heteronuclear bound states. We show that the static electric field induced scattering anisotropy as well as hybridization of rotational states strongly influence two-color photoassociation spectra, leading to significant enhancement in PA rate and large shift. In particular, for static electric field strengths of a few hundred kV/cm, two-color PA rate involving high-lying bound states in electronic ground-state increases by several orders of magnitude even in the weak photoassociative coupling regime

  1. THE DYNAMIC RESPONSE OF THERMOMETER-WELL ASSEMBLIES.

    Science.gov (United States)

    parameter models of the thermometric system were constructed and gave acceptable agreement with the experimental results. These models can be used to predict the dynamic behavior of any similar thermometer system. (Author)

  2. Investigation of the integrated effects of irradiating platinum resistance thermometers

    International Nuclear Information System (INIS)

    Neverov, V.A.; Revyakin, Yu.L.

    1993-01-01

    The development of nuclear energy imposes increased demands on the reliability and quality of the information obtained from primary transducers which monitor the basic parameters of current reactor devices. One of these parameters is the temperature of different modules. This is mainly measured by thermoelectric transducers. Resistance thermometers now being adopted into measurement practice. These provide an initial accuracy of better than plus or minus 273 degrees C and also a normalized systematic error component caused by the action of the temperature. However, a systematic error component resulting from the action of the reactor radiation remains undetermined, and this greatly hinders the extensive use of resistance thermometers in reactor devices. Investigations were made using platinum resistance thermometers of different constructions designs. Irradiation took place in sealed ampules. Each of these contained three thermometers. The fluence achieved was varied by placing the ampules at different heights relative to the central plane of the active zone of the reactor. The irradiation temperature was determined by calculation, taking into account the radiative energy release where the irradiation occurred and the helium gap between the thermometer casing and the walls of an SM-2 reactor channel. Following irradiation in the reactor, the resistance thermometers were calibrated in a special thermometric device providing the minimum contact resistance, uniform heating of the samples, and stabilization of the temperature regime

  3. Measuring Systems for Thermometer Calibration in Low-Temperature Range

    Science.gov (United States)

    Szmyrka-Grzebyk, A.; Lipiński, L.; Manuszkiewicz, H.; Kowal, A.; Grykałowska, A.; Jancewicz, D.

    2011-12-01

    The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium-iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.

  4. THz field engineering in two-color femtosecond filaments using chirped and delayed laser pulses

    Science.gov (United States)

    Nguyen, A.; González de Alaiza Martínez, P.; Thiele, I.; Skupin, S.; Bergé, L.

    2018-03-01

    We numerically study the influence of chirping and delaying several ionizing two-color light pulses in order to engineer terahertz (THz) wave generation in air. By means of comprehensive 3D simulations, it is shown that two chirped pulses can increase the THz yield when they are separated by a suitable time delay for the same laser energy in focused propagation geometry. To interpret these results, the local current theory is revisited and we propose an easy, accessible all-optical criterion that predicts the laser-to-THz conversion efficiencies given any input laser spectrum. In the filamentation regime, numerical simulations display evidence that a chirped pulse is able to produce more THz radiation due to propagation effects, which maintain the two colors of the laser field more efficiently coupled over long distances. A large delay between two pulses promotes multi-peaked THz spectra as well as conversion efficiencies above 10‑4.

  5. Making ultracold molecules in a two-color pump-dump photoassociation scheme using chirped pulses

    International Nuclear Information System (INIS)

    Koch, Christiane P.; Luc-Koenig, Eliane; Masnou-Seeuws, Francoise

    2006-01-01

    This theoretical paper investigates the formation of ground state molecules from ultracold cesium atoms in a two-color scheme. Following previous work on photoassociation with chirped picosecond pulses [Luc-Koenig et al., Phys. Rev. A, 70, 033414 (2004)], we investigate stabilization by a second (dump) pulse. By appropriately choosing the dump pulse parameters and time delay with respect to the photoassociation pulse, we show that a large number of deeply bound molecules are created in the ground triplet state. We discuss (i) broad-bandwidth dump pulses which maximize the probability to form molecules while creating a broad vibrational distribution as well as (ii) narrow-bandwidth pulses populating a single vibrational ground state level, bound by 113 cm -1 . The use of chirped pulses makes the two-color scheme robust, simple, and efficient

  6. Generation of a strong attosecond pulse train with an orthogonally polarized two-color laser field

    International Nuclear Information System (INIS)

    Kim, Chul Min; Kim, I Jong; Nam, Chang Hee

    2005-01-01

    We theoretically investigate the high-order harmonic generation from a neon atom irradiated by an intense two-color femtosecond laser pulse, in which the fundamental field and its second harmonic are linearly polarized and orthogonal to each other. In contrast to usual high-harmonic generation with linearly polarized fundamental field alone, a very strong and clean high-harmonic spectrum, consisting of both odd and even orders of harmonics, can be generated in the orthogonally polarized two-color laser field with proper selection of the relative phase between the fundamental and second-harmonic fields. In time domain, this results in a strong and regular attosecond pulse train. The origin of these behaviors is elucidated by analyzing semiclassical electron paths and by simulating high-harmonic generation quantum mechanically

  7. Making ultracold molecules in a two color pump-dump photoassociation scheme using chirped pulses

    OpenAIRE

    Koch, Christiane P.; Luc-Koenig, Eliane; Masnou-Seeuws, Françoise

    2005-01-01

    This theoretical paper investigates the formation of ground state molecules from ultracold cesium atoms in a two-color scheme. Following previous work on photoassociation with chirped picosecond pulses [Luc-Koenig et al., Phys. Rev. A {\\bf 70}, 033414 (2004)], we investigate stabilization by a second (dump) pulse. By appropriately choosing the dump pulse parameters and time delay with respect to the photoassociation pulse, we show that a large number of deeply bound molecules are created in t...

  8. Two-color stabilization of atomic hydrogen in circularly polarized laser fields

    International Nuclear Information System (INIS)

    Bauer, D.; Ceccherini, F.

    2002-01-01

    The dynamic stabilization of atomic hydrogen against ionization in high-frequency single- and two-color, circularly polarized laser pulses is observed by numerically solving the three-dimensional, time-dependent Schroedinger equation. The single-color case is revisited and numerically determined ionization rates are compared with both, the exact and the approximate high-frequency Floquet rates. The positions of the peaks in the photoelectron spectra can be explained with the help of dressed initial states. In two-color laser fields of opposite circular polarization, the stabilized probability density may be shaped in various ways. For laser frequencies ω 1 and ω 2 =nω 1 , n=2,3,..., and sufficiently large excursion amplitudes (n+1) distinct probability density peaks are observed. This may be viewed as the generalization of the well-known 'dichotomy' in linearly polarized laser fields, i.e, as 'trichotomy', 'quatrochotomy', 'pentachotomy' etc. All those observed structures and their 'hula-hoop'-like dynamics can be understood with the help of high-frequency Floquet theory and the two-color Kramers-Henneberger transformation. The shaping of the probability density in the stabilization regime can be realized without additional loss in the survival probability, as compared to the corresponding single-color results

  9. Single attosecond pulse generation in an orthogonally polarized two-color laser field combined with a static electric field

    International Nuclear Information System (INIS)

    Xia Changlong; Zhang Gangtai; Wu Jie; Liu Xueshen

    2010-01-01

    We investigate theoretic high-order harmonic generation and single attosecond pulse generation in an orthogonally polarized two-color laser field, which is synthesized by a mid-infrared (IR) pulse (12.5 fs, 2000 nm) in the y component and a much weaker (12 fs, 800 nm) pulse in the x component. We find that the width of the harmonic plateau can be extended when a static electric field is added in the y component. We also investigate emission time of harmonics in terms of a time-frequency analysis to illustrate the physical mechanism of high-order harmonic generation. We calculate the ionization rate using the Ammosov-Delone-Krainov model and interpret the variation of harmonic intensity for different static electric field strengths. When the ratio of strengths of the static and the y-component laser fields is 0.1, a continuous harmonic spectrum is formed from 220 to 420 eV. By superposing a properly selected range of the harmonic spectrum from 300 to 350 eV, an isolated attosecond pulse with a duration of about 75 as is obtained, which is near linearly polarized.

  10. An inexpensive high-temperature optical fiber thermometer

    International Nuclear Information System (INIS)

    Moore, Travis J.; Jones, Matthew R.; Tree, Dale R.; Allred, David D.

    2017-01-01

    An optical fiber thermometer consists of an optical fiber whose tip is coated with a highly conductive, opaque material. When heated, this sensing tip becomes an isothermal cavity that emits like a blackbody. This emission is used to predict the sensing tip temperature. In this work, analytical and experimental research has been conducted to further advance the development of optical fiber thermometry. An inexpensive optical fiber thermometer is developed by applying a thin coating of a high-temperature cement onto the tip of a silica optical fiber. An FTIR spectrometer is used to detect the spectral radiance exiting the fiber. A rigorous mathematical model of the irradiation incident on the detection system is developed. The optical fiber thermometer is calibrated using a blackbody radiator and inverse methods are used to predict the sensing tip temperature when exposed to various heat sources. - Highlights: • An inexpensive coating for an optical fiber thermometer sensing tip is tested. • Inverse heat transfer methods are used to estimate the sensing tip temperature. • An FTIR spectrometer is used as the detector to test the optical fiber thermometer using various heat sources.

  11. Assessing probe-specific dye and slide biases in two-color microarray data

    Directory of Open Access Journals (Sweden)

    Goldberg Zelanna

    2008-07-01

    Full Text Available Abstract Background A primary reason for using two-color microarrays is that the use of two samples labeled with different dyes on the same slide, that bind to probes on the same spot, is supposed to adjust for many factors that introduce noise and errors into the analysis. Most users assume that any differences between the dyes can be adjusted out by standard methods of normalization, so that measures such as log ratios on the same slide are reliable measures of comparative expression. However, even after the normalization, there are still probe specific dye and slide variation among the data. We define a method to quantify the amount of the dye-by-probe and slide-by-probe interaction. This serves as a diagnostic, both visual and numeric, of the existence of probe-specific dye bias. We show how this improved the performance of two-color array analysis for arrays for genomic analysis of biological samples ranging from rice to human tissue. Results We develop a procedure for quantifying the extent of probe-specific dye and slide bias in two-color microarrays. The primary output is a graphical diagnostic of the extent of the bias which called ECDF (Empirical Cumulative Distribution Function, though numerical results are also obtained. Conclusion We show that the dye and slide biases were high for human and rice genomic arrays in two gene expression facilities, even after the standard intensity-based normalization, and describe how this diagnostic allowed the problems causing the probe-specific bias to be addressed, and resulted in important improvements in performance. The R package LMGene which contains the method described in this paper has been available to download from Bioconductor.

  12. Two-color planar laser-induced fluorescence thermometry in aqueous solutions

    International Nuclear Information System (INIS)

    Robinson, G. Andrew; Lucht, Robert P.; Laurendeau, Normand M.

    2008-01-01

    We demonstrate a two-color planar laser-induced fluorescence technique for obtaining two-dimensional temperature images in water. For this method, a pulsed Nd:YAG laser at 532 nm excites a solution of temperature-sensitive rhodamine 560 and temperature-insensitive sulforhodamine 640. The resulting emissions are optically separated through filters and detected via a charged-couple device (CCD) camera system. A ratio of the two images yields temperature images independent of incident irradiance. An uncertainty in temperature of ±1.4 deg. C is established at the 95% confidence interval

  13. Two-color QCD with non-zero chiral chemical potential

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, V.V. [Institute for High Energy Physics NRC “Kurchatov Institute' ,142281 Protvino (Russian Federation); Far Eastern Federal University, School of Biomedicine,690950 Vladivostok (Russian Federation); Goy, V.A. [Far Eastern Federal University, School of Natural Sciences,690950 Vladivostok (Russian Federation); Ilgenfritz, E.M. [Joint Institute for Nuclear Research,BLTP, 141980 Dubna (Russian Federation); Kotov, A.Yu. [Institute of Theoretical and Experimental Physics,117259 Moscow (Russian Federation); Molochkov, A.V. [Far Eastern Federal University, School of Biomedicine,690950 Vladivostok (Russian Federation); Müller-Preussker, M.; Petersson, B. [Humboldt-Universität zu Berlin, Institut für Physik,12489 Berlin (Germany)

    2015-06-16

    The phase diagram of two-color QCD with non-zero chiral chemical potential is studied by means of lattice simulation. We focus on the influence of a chiral chemical potential on the confinement/deconfinement phase transition and the breaking/restoration of chiral symmetry. The simulation is carried out with dynamical staggered fermions without rooting. The dependences of the Polyakov loop, the chiral condensate and the corresponding susceptibilities on the chiral chemical potential and the temperature are presented. The critical temperature is observed to increase with increasing chiral chemical potential.

  14. Stokes image reconstruction for two-color microgrid polarization imaging systems.

    Science.gov (United States)

    Lemaster, Daniel A

    2011-07-18

    The Air Force Research Laboratory has developed a new microgrid polarization imaging system capable of simultaneously reconstructing linear Stokes parameter images in two colors on a single focal plane array. In this paper, an effective method for extracting Stokes images is presented for this type of camera system. It is also shown that correlations between the color bands can be exploited to significantly increase overall spatial resolution. Test data is used to show the advantages of this approach over bilinear interpolation. The bounds (in terms of available reconstruction bandwidth) on image resolution are also provided.

  15. Adiabatic surface thermometer for improved production braze quality

    International Nuclear Information System (INIS)

    Dittbenner, G.R.

    1975-01-01

    An adiabatic surface thermometer was developed to control automatically the critical temperature-time cycle of a production vacuum-brazing process. Investigations revealed that optimum braze-joint strength required precise control of the brazing temperature. Spot-welded thermocouples could not be used because the spot welds cause surface damage. This thermometer touches the surface and uses a differential thermocouple and heater to measure surface temperature without heat flow, thereby eliminating large errors caused by conduction losses common to conventional spring-loaded thermocouples. Temperatures in air or vacuum are measured to 800 0 C with errors less than 5 0 C. This thermometer has minimized the rejection of production parts, resulting in a cost saving to the U. S. Energy Research and Development Administration

  16. The carbon dioxide thermometer and the cause of global warming

    International Nuclear Information System (INIS)

    Calder, Nigel

    1999-01-01

    Carbon dioxide in the air may be increasing because the world is warming. This possibility, which contradicts the hypothesis of an enhanced greenhouse warming driven by manmade emissions, is here pursued in two ways. First, increments in carbon dioxide are treated as readings of a natural thermometer that tracks global and hemispheric temperature deviations, as gauged by meteorologists' thermometers. Calibration of the carbon dioxide thermometer to conventional temperatures then leads to a history of carbon dioxide since 1856 that diverges from the ice-core record. Secondly, the increments of carbon dioxide can also be accounted for, without reference to temperature, by the combined effects of cosmic rays, El Nino and volcanoes. The most durable effect is due to cosmic rays. A solar wind history, used as a long-term proxy for the cosmic rays, gives a carbon dioxide history similar to that inferred from the global temperature deviations. (author)

  17. Ultrafast Paper Thermometers Based on a Green Sensing Ink.

    Science.gov (United States)

    Tao, Xinglei; Jia, Hanyu; He, Yonglin; Liao, Shenglong; Wang, Yapei

    2017-03-24

    With the use of an ionic liquid as the ultrathermosensitive fluid, a paper thermometer is successfully developed with intrinsic ability of ultrafast response and high stability upon temperature change. The fluidic nature allows the ionic liquid to be easily deposited on paper by pen writing or inkjet printing, affording great promise for large-scale fabrication of low-cost paper sensors. Owing to the advantages of nonvolatilization, excellent continuity and deformability, the thermosensitive ink trapped within the cellulose fibers of paper matrix has no leakage or evaporation at open states, ensuring the excellent stability and repeatability of thermal sensing against arbitrary bending and folding operation. By shortening the heat exchange distance between ionic liquid and samples, it takes only 8 s for the thermometer to reach an electrical equilibrium at a given temperature. Moreover, the paper thermometer can be applied to remotely monitor temperature change with the combination of a wireless communication technology.

  18. Crustal Strain Observation Using a Two-Color Interferometer with Accurate Correction of Refractive Index of Air

    Directory of Open Access Journals (Sweden)

    Souichi Telada

    2014-07-01

    Full Text Available A highly accurate two-color interferometer with automatic correction of the refractive index of air was developed for crustal strain observation. The two-color interferometer, which can measure a geometrical distance of approximately 70 m, with a relative resolution of 2 × 10−9, clearly detected a change in strain due to earth tides in spite of optical measurement in air. Moreover, a large strain quake due to an earthquake could be observed without disturbing the measurement. We demonstrated the advantages of the two-color interferometer in air for geodetic observation.

  19. Accuracy of the Danish version of the 'distress thermometer'

    DEFF Research Database (Denmark)

    Bidstrup, Pernille Envold; Mertz, Birgitte Goldschmidt; Dalton, Susanne Oksbjerg

    2012-01-01

    Objective: Short screening instruments have been suggested to improve the detection of psychological symptoms. We examined the accuracy of the Danish version of the 'Distress Thermometer'. Methods: Between October 2008 and October 2009, 426 women with newly diagnosed primary breast cancer who were...... operated at the Breast Surgery Clinic of the Rigshospitalet, Copenhagen, were eligible for this study. Of these, 357 participated (84%) and 333 completed a questionnaire. The distress thermometer was evaluated against the 'hospital anxiety and depression scale' (HADS). We also examined the women's wish...

  20. Controlling of the electromagnetic solitary waves generation in the wake of a two-color laser

    Science.gov (United States)

    Pan, K. Q.; Li, S. W.; Guo, L.; Yang, D.; Li, Z. C.; Zheng, C. Y.; Jiang, S. E.; Zhang, B. H.; He, X. T.

    2018-05-01

    Electromagnetic solitary waves generated by a two-color laser interaction with an underdense plasma are investigated. It is shown that, when the former wave packet of the two-color laser is intense enough, it will excite nonlinear wakefields and generate electron density cavities. The latter wave packets will beat with the nonlinear wakefield and generate both high-frequency and low-frequency components. When the peak density of the cavities exceeds the critical density of the low-frequency component, this part of the electromagnetic field will be trapped to generate electromagnetic solitary waves. By changing the laser and plasma parameters, we can control the wakefield generation, which will also control the generation of the solitary waves. One-dimensional particle-in-cell simulations are performed to prove the controlling of the solitary waves. The simulation results also show that solitary waves generated by higher laser intensities will become moving solitary waves. The two-dimensional particle-in-cell also shows the generation of the solitary waves. In the two-dimensional case, solitary waves are distributed in the transverse directions because of the filamentation instability.

  1. Absolute distance measurement with correction of air refractive index by using two-color dispersive interferometry.

    Science.gov (United States)

    Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua

    2016-10-17

    Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.

  2. Measurement of body temperature by use of auricular thermometers versus rectal thermometers in dogs with otitis externa.

    Science.gov (United States)

    González, A Michelle; Mann, F A; Preziosi, Diane E; Meadows, Richard L; Wagner-Mann, Colette C

    2002-08-01

    To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. Prospective study. 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.

  3. A low-temperature (4-300K) constant volume gas thermometer

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1976-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300K may be obtained. The principle is outlined, then the gas thermometer and its auxiliary equipment are briefly described; the corrections to be applied to the results are given and a table shows the values obtained [fr

  4. Optimal designs for one- and two-color microarrays using mixed models: a comparative evaluation of their efficiencies.

    Science.gov (United States)

    Lima Passos, Valéria; Tan, Frans E S; Winkens, Bjorn; Berger, Martijn P F

    2009-01-01

    Comparative studies between the one- and two-color microarrays provide supportive evidence for similarities of results on differential gene expression. So far, no design comparisons between the two platforms have been undertaken. With the objective of comparing optimal designs of one- and two-color microarrays in their statistical efficiencies, techniques of design optimization were applied within a mixed model framework. A- and D-optimal designs for the one- and two-color platforms were sought for a 3 x 3 factorial experiment. The results suggest that the choice of the platform will not affect the "subjects to groups" allocation, being concordant in the two designs. However, under financial constraints, the two-color arrays are expected to have a slight upper hand in terms of efficiency of model parameters estimates, once the price of arrays is more expensive than that of subjects. This statement is especially valid for microarray studies envisaging class comparisons.

  5. A Non-Mercury Thermometer Alternative for Use in Older Melting Point Apparatuses

    Science.gov (United States)

    Ongley, Lois K.; Kern, Clayton S.; Woods, Barry W.

    2008-01-01

    The State of Maine seeks to eliminate most mercury use. This includes removing mercury thermometers from secondary schools and discouraging Hg use in other educational institutions. Alternatives to mercury thermometers in chemical laboratory work include non-mercury thermometers, temperature probes, and thermocouples. In organic chemistry mercury…

  6. Cryogenic particle detectors with superconducting phase transition thermometers

    International Nuclear Information System (INIS)

    Ferger, P.; Colling, P.; Bucci, C.; Nucciotti, A.; Buehler, M.; Cooper, S.; Feilitzsch, F. v.; Forster, G.; Gabutti, A.; Hoehne, J.; Igalson, J.; Kellner, E.; Loidl, M.; Meier, O.; Nagel, U.; Proebst, F.; Rulofs, A.; Schanda, U.; Seidel, W.; Sisti, M.; Stodolsky, L.; Stolovich, A.; Zerle, L.

    1996-01-01

    A tungsten superconducting phase transition thermometer on a 32 g sapphire crystal has given an energy resolution of 100 eV (FWHM) for 1.5 keV X-rays, increasing to 440 eV at 14 keV. A possibility to obtain similar resolution in much larger crystals by using Al films as phonon collectors is presented. (orig.)

  7. 27 CFR 30.22 - Hydrometers and thermometers.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Hydrometers and... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS GAUGING MANUAL Gauging Instruments § 30.22 Hydrometers and thermometers. The hydrometers used are graduated to read the proof of aqueous alcoholic solutions at 60 degrees...

  8. SQUID-based noise thermometer for sub-Millikelvin refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Marco; Beyer, Joern; Klemm, Monique [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany); Alivaliollahi, Sassan; Barthelmess, Henry [Magnicon GmbH, Barkhausenweg 11, 22339 Hamburg (Germany)

    2015-07-01

    The magnetic field fluctuation thermometer (MFFT) is a high-accuracy SQUID-based noise thermometer suitable for sub-Kelvin thermometry. A highly sensitive low-Tc SQUID magnetometer detects inductively the magnetic field fluctuation above a metal surface. The fluctuations are generated by the thermal activated noise currents inside the metal body that is thermally anchored to the temperature stage to be measured. The spectral shape is independent of temperature as the electrical conductivity is constant and the geometry is fixed. The magnetic noise power spectral amplitudes at any frequencies are directly proportional to temperature. Hence, only one reference measurement at a known temperature is required for calibration. A complete MFFT thermometer system for the temperature range of ca. 4 K down to <10 mK is commercially available. We have now developed an integrated MFFT with an extended range of operation down to <1 mK. For this purpose the sensitivity of the SQUID sensor has been increased, the metal body geometry modified and the magnetic shielding of the MFFT module improved. These modifications make it possible to obtain a thermometer noise temperature of <10 μK. We discuss the rationale for our MFFT configuration and present numerical simulations and experimental results.

  9. Hadron wave functions as a probe of a two-color baryonic medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Alessandro [Swansea University, Department of Physics, College of Science, Swansea (United Kingdom); University of Helsinki, Department of Physics and Helsinki Institute of Physics, P.O. Box 64, Helsinki (Finland); Giudice, Pietro [Universitaet Muenster, Institut fuer Theoretische Physik, Muenster (Germany); Hands, Simon [Swansea University, Department of Physics, College of Science, Swansea (United Kingdom)

    2015-04-01

    The properties of the ground state of two-color QCD at non-zero baryon chemical potential μ present an interesting problem in strongly interacting gauge theory; in particular the nature of the physically relevant degrees of freedom in the superfluid phase in the post-onset regime μ > m{sub π} /2 still needs clarification. In this study we present evidence for in-medium effects at high μ by studying the wave functions of mesonic and diquark states using orthodox lattice simulation techniques, made possible by the absence of a sign problem for the model with N{sub f} = 2. Our results show that beyond onset the spatial extent of hadrons decreases as μ grows, and that the wave function profiles are consistent with the existence of a dynamically gapped Fermi surface in this regime. (orig.)

  10. Non-destructive spatial characterization of buried interfaces in multilayer stacks via two color picosecond acoustics

    Science.gov (United States)

    Faria, Jorge C. D.; Garnier, Philippe; Devos, Arnaud

    2017-12-01

    We demonstrate the ability to construct wide-area spatial mappings of buried interfaces in thin film stacks in a non-destructive manner using two color picosecond acoustics. Along with the extraction of layer thicknesses and sound velocities from acoustic signals, the morphological information presented is a powerful demonstration of phonon imaging as a metrological tool. For a series of heterogeneous (polymer, metal, and semiconductor) thin film stacks that have been treated with a chemical procedure known to alter layer properties, the spatial mappings reveal changes to interior thicknesses and chemically modified surface features without the need to remove uppermost layers. These results compare well to atomic force microscopy scans showing that the technique provides a significant advantage to current characterization methods for industrially important device stacks.

  11. Long-Range Predissociation in Two-Color Photoassociation of Ultracold Na Atoms

    International Nuclear Information System (INIS)

    Molenaar, P.A.; van der Straten, P.; Heideman, H.G.

    1996-01-01

    We report two-color photoassociative ionization of sodium in a magneto-optical trap. The experimental results yield information on both singly and doubly excited states. We find that the highest bound vibrational levels (v approx-gt 20) of the singly excited 0 g - state predissociate into the 3 2 P 3/2 +3 2 S 1/2 (F g =1) dissociation continuum due to avoided crossings of the hyperfine components of this potential with other molecular symmetries. Based on symmetry and energy consideration we argue that a doubly excited 1 u state remains autoionizing even when only a few GHz above the dissociation continuum. copyright 1996 The American Physical Society

  12. Calibration of a two-color soft x-ray diagnostic for electron temperature measurement

    Energy Technology Data Exchange (ETDEWEB)

    Reusch, L. M., E-mail: lmmcguire@wisc.edu; Den Hartog, D. J.; Goetz, J.; McGarry, M. B. [University of Wisconsin - Madison, Madison, Wisconsin 53703 (United States); Franz, P. [Consorzio RFX, Padova (Italy); Stephens, H. D. [University of Wisconsin - Madison, Madison, Wisconsin 53703 (United States); Pierce College Fort Steilacoom, Lakewood, Washington 98498 (United States)

    2016-11-15

    The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXR{sub DF}) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXR{sub DF} measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXR{sub DF} discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXR{sub DF} analysis rather than instrumentation effects.

  13. Two-color Fermi-liquid theory for transport through a multilevel Kondo impurity

    Science.gov (United States)

    Karki, D. B.; Mora, Christophe; von Delft, Jan; Kiselev, Mikhail N.

    2018-05-01

    We consider a quantum dot with K ≥2 orbital levels occupied by two electrons connected to two electric terminals. The generic model is given by a multilevel Anderson Hamiltonian. The weak-coupling theory at the particle-hole symmetric point is governed by a two-channel S =1 Kondo model characterized by intrinsic channels asymmetry. Based on a conformal field theory approach we derived an effective Hamiltonian at a strong-coupling fixed point. The Hamiltonian capturing the low-energy physics of a two-stage Kondo screening represents the quantum impurity by a two-color local Fermi liquid. Using nonequilibrium (Keldysh) perturbation theory around the strong-coupling fixed point we analyze the transport properties of the model at finite temperature, Zeeman magnetic field, and source-drain voltage applied across the quantum dot. We compute the Fermi-liquid transport constants and discuss different universality classes associated with emergent symmetries.

  14. Memory effects, two color percolation, and the temperature dependence of Mott variable-range hopping

    Science.gov (United States)

    Agam, Oded; Aleiner, Igor L.

    2014-06-01

    There are three basic processes that determine hopping transport: (a) hopping between normally empty sites (i.e., having exponentially small occupation numbers at equilibrium), (b) hopping between normally occupied sites, and (c) transitions between normally occupied and unoccupied sites. In conventional theories all these processes are considered Markovian and the correlations of occupation numbers of different sites are believed to be small (i.e., not exponential in temperature). We show that, contrary to this belief, memory effects suppress the processes of type (c) and manifest themselves in a subleading exponential temperature dependence of the variable-range hopping conductivity. This temperature dependence originates from the property that sites of type (a) and (b) form two independent resistor networks that are weakly coupled to each other by processes of type (c). This leads to a two-color percolation problem which we solve in the critical region.

  15. Two-Color Single-Photon Photoinitiation and Photoinhibition for Subdiffraction Photolithography

    Science.gov (United States)

    Scott, Timothy F.; Kowalski, Benjamin A.; Sullivan, Amy C.; Bowman, Christopher N.; McLeod, Robert R.

    2009-05-01

    Controlling and reducing the developed region initiated by photoexposure is one of the fundamental goals of optical lithography. Here, we demonstrate a two-color irradiation scheme whereby initiating species are generated by single-photon absorption at one wavelength while inhibiting species are generated by single-photon absorption at a second, independent wavelength. Co-irradiation at the second wavelength thus reduces the polymerization rate, delaying gelation of the material and facilitating enhanced spatial control over the polymerization. Appropriate overlapping of the two beams produces structures with both feature sizes and monomer conversions otherwise unobtainable with use of single- or two-photon absorption photopolymerization. Additionally, the generated inhibiting species rapidly recombine when irradiation with the second wavelength ceases, allowing for fast sequential exposures not limited by memory effects in the material and thus enabling fabrication of complex two- or three-dimensional structures.

  16. Fabrication of optical multilayer for two-color phase plate in super-resolution microscope.

    Science.gov (United States)

    Iketaki, Yoshinori; Kitagawa, Katsuichi; Hidaka, Kohjiro; Kato, Naoki; Hirabayashi, Akira; Bokor, Nandor

    2014-07-01

    In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

  17. Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

    International Nuclear Information System (INIS)

    Iketaki, Yoshinori; Kitagawa, Katsuichi; Hidaka, Kohjiro; Kato, Naoki; Hirabayashi, Akira; Bokor, Nandor

    2014-01-01

    In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope

  18. Design of a real-time two-color interferometer for MAST Upgrade

    International Nuclear Information System (INIS)

    O’Gorman, T.; Naylor, G.; Scannell, R.; Cunningham, G.; Martin, R.; Croft, D.; Brunner, K. J.

    2014-01-01

    A single chord two-color CO 2 /HeNe (10.6/0.633 μm) heterodyne laser interferometer has been designed to measure the line integral electron density along the mid-plane of the MAST Upgrade tokamak, with a typical error of 1 × 10 18 m −3 (∼2° phase error) at 4 MHz temporal resolution. To ensure this diagnostic system can be restored from any failures without stopping MAST Upgrade operations, it has been located outside of the machine area. The final design and initial testing of this system, including details of the optics, vibration isolation, and a novel phase detection scheme are discussed in this paper

  19. A dual-targeting upconversion nanoplatform for two-color fluorescence imaging-guided photodynamic therapy.

    Science.gov (United States)

    Wang, Xu; Yang, Cheng-Xiong; Chen, Jia-Tong; Yan, Xiu-Ping

    2014-04-01

    The targetability of a theranostic probe is one of the keys to assuring its theranostic efficiency. Here we show the design and fabrication of a dual-targeting upconversion nanoplatform for two-color fluorescence imaging-guided photodynamic therapy (PDT). The nanoplatform was prepared from 3-aminophenylboronic acid functionalized upconversion nanocrystals (APBA-UCNPs) and hyaluronated fullerene (HAC60) via a specific diol-borate condensation. The two specific ligands of aminophenylboronic acid and hyaluronic acid provide synergistic targeting effects, high targetability, and hence a dramatically elevated uptake of the nanoplatform by cancer cells. The high generation yield of (1)O2 due to multiplexed Förster resonance energy transfer between APBA-UCNPs (donor) and HAC60 (acceptor) allows effective therapy. The present nanoplatform shows great potential for highly selective tumor-targeted imaging-guided PDT.

  20. Spatial properties of a terahertz beam generated from a two-color air plasma

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Wang, Tianwu; Buron, Jonas Christian Due

    2013-01-01

    We present a spatial characterization of terahertz (THz) beams generated from a two-color air plasma under different conditions by measuring full 3D beam profiles using a commercial THz camera. We compare two THz beam profiles emitted from plasmas generated by 35 fs and 100 fs laser pulses...... that this reduces the beam waist, and that the beam spot shape changes from Lorentzian to Gaussian. Finally, we observe a forward-propagating Gaussian THz beam by spatially filtering away the conical off-axis radiation with a 1 cm aperture......., and show that the spatial properties of the two THz beams do not change significantly. For the THz beam profile generated by the 35 fs pulse, the spatial effect of eliminating the lower frequencies is investigated by implementing two crossed polarizers working as a high-pass filter. We show...

  1. Melting the diquark condensate in two-color QCD: A renormalization group analysis

    International Nuclear Information System (INIS)

    Wirstam, J.; Lenaghan, J.T.; Splittorff, K.

    2003-01-01

    We use a Landau theory and the ε expansion to study the superfluid phase transition of two-color QCD at a nonzero temperature T and baryonic chemical potential μ. At low T, and for N f flavors of massless quarks, the global SU(N f )xSU(N f )xU(1) symmetry is spontaneously broken by a diquark condensate down to Sp(N f )xSp(N f ) for any μ>0. As the temperature increases, the diquark condensate melts, and at sufficiently large T the symmetry is restored. Using renormalization group arguments, we find that in the presence of the chiral anomaly term there can be a second order phase transition when N f =2 or N f ≥6, while the transition is first order for N f =4. We discuss the relevance of these results for the emergence of a tricritical point recently observed in lattice simulations

  2. Mechanisms of two-color laser-induced field-free molecular orientation.

    Science.gov (United States)

    Spanner, Michael; Patchkovskii, Serguei; Frumker, Eugene; Corkum, Paul

    2012-09-14

    Two mechanisms of two-color (ω+2ω) laser-induced field-free molecular orientation, based on the hyperpolarizability and ionization depletion, are explored and compared. The CO molecule is used as a computational example. While the hyperpolarizability mechanism generates small amounts of orientation at intensities below the ionization threshold, ionization depletion quickly becomes the dominant mechanism as soon as ionizing intensities are reached. Only the ionization mechanism leads to substantial orientation (e.g., on the order of ≳0.1). For intensities typical of laser-induced molecular alignment and orientation experiments, the two mechanisms lead to robust, characteristic timings of the field-free orientation wave-packet revivals relative to the alignment revivals and the revival time. The revival timings can be used to detect the active orientation mechanism experimentally.

  3. Two-color visible/vacuum ultraviolet photoelectron imaging dynamics of Br2.

    Science.gov (United States)

    Plenge, Jürgen; Nicolas, Christophe; Caster, Allison G; Ahmed, Musahid; Leone, Stephen R

    2006-10-07

    An experimental two-color photoionization dynamics study of laser-excited Br2 molecules is presented, combining pulsed visible laser excitation and tunable vacuum ultraviolet (VUV) synchrotron radiation with photoelectron imaging. The X 1Sigmag + -B 3Pi0+u transition in Br2 is excited at 527 nm corresponding predominantly to excitation of the v' = 28 vibrational level in the B 3Pi0+u state. Tunable VUV undulator radiation in the energy range of 8.40-10.15 eV is subsequently used to ionize the excited molecules to the X 2Pi32,12 state of the ion, and the ionic ground state is probed by photoelectron imaging. Similar experiments are performed using single-photon synchrotron ionization in the photon energy range of 10.75-12.50 eV without any laser excitation. Photoelectron kinetic energy distributions are extracted from the photoelectron images. In the case of two-color photoionization using resonant excitation of the intermediate B 3Pi0+u state, a broad distribution of photoelectron kinetic energies is observed, and in some cases even a bimodal distribution, which depends on the VUV photon energy. In contrast, for single-photon ionization, a single nearly Gaussian-shaped distribution is observed, which shifts to higher energy with photon energy. Simulated spectra based on Franck-Condon factors for the transitions Br2(X 1Sigmag+, v" = 0)-Br2 +(X 2Pi12,32, v+) and Br2(B 3Pi0+u, v' = 28)-Br2 +(X 2Pi12,32, v+) are generated. Comparison of these calculated spectra with the measured images suggests that the differences in the kinetic energy distributions for the two ionization processes reflect the different extensions of the vibrational wave functions in the v" = 0 electronic ground state (X 1Sigmag+) versus the electronically and vibrationally excited state (B 3Pi0+u, v' = 28).

  4. Validation of Calculations in a Digital Thermometer Firmware

    Science.gov (United States)

    Batagelj, V.; Miklavec, A.; Bojkovski, J.

    2014-04-01

    State-of-the-art digital thermometers are arguably remarkable measurement instruments, measuring outputs from resistance thermometers and/or thermocouples. Not only that they can readily achieve measuring accuracies in the parts-per-million range, but they also incorporate sophisticated algorithms for the transformation calculation of the measured resistance or voltage to temperature. These algorithms often include high-order polynomials, exponentials and logarithms, and must be performed using both standard coefficients and particular calibration coefficients. The numerical accuracy of these calculations and the associated uncertainty component must be much better than the accuracy of the raw measurement in order to be negligible in the total measurement uncertainty. In order for the end-user to gain confidence in these calculations as well as to conform to formal requirements of ISO/IEC 17025 and other standards, a way of validation of these numerical procedures performed in the firmware of the instrument is required. A software architecture which allows a simple validation of internal measuring instrument calculations is suggested. The digital thermometer should be able to expose all its internal calculation functions to the communication interface, so the end-user can compare the results of the internal measuring instrument calculation with reference results. The method can be regarded as a variation of the black-box software validation. Validation results on a thermometer prototype with implemented validation ability show that the calculation error of basic arithmetic operations is within the expected rounding error. For conversion functions, the calculation error is at least ten times smaller than the thermometer effective resolution for the particular probe type.

  5. The gamma thermometer as a measuring instrument of the nuclear power of a LWR core

    International Nuclear Information System (INIS)

    Hantouche, C.

    1984-07-01

    After a presentation of the gamma thermometer and its environment, this thesis deals with the calibration of a gamma thermometer or determination of the thermal transfer ratio of the signal. Then, the acquisition systems for signals obtained from gamma thermometers installed in PWR nuclear power plants are presented. One deals also with the nuclear transfer function establishment and deconvolution. Then, one deals with the reconstruction of the axial power of an assembly provided with a gamma thermometer. Qualitative and quantitative studies of measurements obtained from this gamma thermometer are finally presented. 64 refs [fr

  6. Infrared detection with high-[Tc] bolometers and response of Nb tunnel junctions to picosecond voltage pulses

    Energy Technology Data Exchange (ETDEWEB)

    Verghese, S.

    1993-05-01

    Oxide superconductors with high critical temperature [Tc] make sensitive thermometers for several types of infrared bolometers. The authors built composite bolometers with YBa[sub 2]Cu[sub 3]O[sub 7[minus][delta

  7. Effect of on-chip filter on Coulomb blockade thermometer

    International Nuclear Information System (INIS)

    Roschier, L; Penttilä, J S; Gunnarsson, D; Prunnila, M; Meschke, M; Savin, A

    2012-01-01

    Coulomb Blockade Thermometer (CBT) is a primary thermometer based on electric conductance of normal tunnel junction arrays. One limitation for CBT use at the lowest temperatures has been due to environmental noise heating. To improve on this limitation, we have done measurements on CBT sensors fabricated with different on-chip filtering structures in a dilution refrigerator with a base temperature of 10 mK. The CBT sensors were produced with a wafer scale tunnel junction process. We present how the different on-chip filtering schemes affect the limiting saturation temperatures and show that CBT sensors with proper on-chip filtering work at temperatures below 20 mK and are tolerant to noisy environment.

  8. Investigations on perturbations of microwave dielectric resonator thermometer

    International Nuclear Information System (INIS)

    Yu, Lili; Zhang, Guangming; Fernicola, V; Lu, Jinchuan

    2017-01-01

    Investigations of antenna probe length, antenna-dielectric distance, cavity filling and humidity on microwave resonator thermometer with respect to Q , spurious mode depression, coupling strength, accuracy, shock resistance or sensitivity were carried out in order to improve the dielectric resonator thermometer performance. Significant improvement of Q and depression of spurious mode coupling were obtained when the antenna length was reduced. It also turns out that the Q and spurious mode coupling strength vary with the distance between dielectric and antenna pin, as well under appropriate antenna length. Filling the cavity with nitrogen increases coupling strength but decrease frequency-temperature sensitivity compared to a vacuum-pumped cavity. Besides, preliminary results on the microwave resonator sensitivity to air humidity were obtained. (technical note)

  9. Laser-induced plasmas in air studied using two-color interferometry

    International Nuclear Information System (INIS)

    Yang, Zefeng; Wu, Jian; Li, Xingwen; Han, Jiaxun; Jia, Shenli; Qiu, Aici; Wei, Wenfu

    2016-01-01

    Temporally and spatially resolved density profiles of Cu atoms, electrons, and compressed air, from laser-induced copper plasmas in air, are measured using fast spectral imaging and two-color interferometry. From the intensified CCD images filtered by a narrow-band-pass filter centered at 515.32 nm, the Cu atoms expansion route is estimated and used to determine the position of the fracture surface between the Cu atoms and the air. Results indicate that the Cu atoms density at distances closer to the target (0–0.4 mm) is quite low, with the maximum density appearing at the edge of the plasma's core being ∼4.6 × 10"2"4" m"−"3 at 304 ns. The free electrons are mainly located in the internal region of the plume, which is supposed to have a higher temperature. The density of the shock wave is (4–6) × 10"2"5" m"−"3, corresponding to air compression of a factor of 1.7–2.5.

  10. Phase diagram of dense two-color QCD within lattice simulations

    Directory of Open Access Journals (Sweden)

    Braguta V.V.

    2017-01-01

    Full Text Available We present the results of a low-temperature scan of the phase diagram of dense two-color QCD with Nf = 2 quarks. The study is conducted using lattice simulation with rooted staggered quarks. At small chemical potential we observe the hadronic phase, where the theory is in a confining state, chiral symmetry is broken, the baryon density is zero and there is no diquark condensate. At the critical point μ = mπ/2 we observe the expected second order transition to Bose-Einstein condensation of scalar diquarks. In this phase the system is still in confinement in conjunction with nonzero baryon density, but the chiral symmetry is restored in the chiral limit. We have also found that in the first two phases the system is well described by chiral perturbation theory. For larger values of the chemical potential the system turns into another phase, where the relevant degrees of freedom are fermions residing inside the Fermi sphere, and the diquark condensation takes place on the Fermi surface. In this phase the system is still in confinement, chiral symmetry is restored and the system is very similar to the quarkyonic state predicted by SU(Nc theory at large Nc.

  11. QCD with two colors at finite baryon density at next-to-leading order

    International Nuclear Information System (INIS)

    Splittorff, K.; Toublan, D.; Verbaarschot, J.J.M.

    2002-01-01

    We study QCD with two colors and quarks in the fundamental representation at finite baryon density in the limit of light-quark masses. In this limit the free energy of this theory reduces to the free energy of a chiral Lagrangian which is based on the symmetries of the microscopic theory. In earlier work this Lagrangian was analyzed at the mean-field level and a phase transition to a phase of condensed diquarks was found at a chemical potential of half the diquark mass (which is equal to the pion mass). In this article we analyze this theory at next-to-leading order in chiral perturbation theory. We show that the theory is renormalizable and calculate the next-to-leading order free energy in both phases of the theory. By deriving a Landau-Ginzburg theory for the order parameter we show that the finite one-loop contribution and the next-to-leading order terms in the chiral Lagrangian do not qualitatively change the phase transition. In particular, the critical chemical potential is equal to half the next-to-leading order pion mass, and the phase transition is of second order

  12. Double ionization of nitrogen molecules in orthogonal two-color femtosecond laser fields

    Science.gov (United States)

    Song, Qiying; Li, Hui; Wang, Junping; Lu, Peifen; Gong, Xiaochun; Ji, Qinying; Lin, Kang; Zhang, Wenbin; Ma, Junyang; Li, Hanxiao; Zeng, Heping; He, Feng; Wu, Jian

    2018-04-01

    Double ionization of nitrogen molecules in orthogonally polarized two-color femtosecond laser fields is investigated by varying the relative intensity between the fundamental wave (FW) and its second harmonic (SH) components. The yield ratios of the double ionization channels, i.e., the non-dissociative {{{{N}}}2}2+ and Coulomb exploded (N+, N+), to the singly charged N2 + channel exhibit distinct dependences on the relative strength between the FW and SH fields. As the intensity ratio of SH to FW increases, the yield ratio of (N+, N+)/N2 + gradually increases, while the ratio of {{{{N}}}2}2+/N2 + first descends and then increases constituting a valley shape which is similar to the behavior of Ar2+/Ar+ observed in the same experimental condition. Based on the classical trajectory simulations, we found that the different characteristics of the two doubly ionized channels stem from two mechanisms, i.e., the {{{{N}}}2}2+ is mostly accessed by the (e, 2e) impact ionization while the recollision-induced excitation with subsequent ionization plays an important role in producing the (N+, N+) channel.

  13. Opportunities for two-color experiments at the SASE3 undulator line of the European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca; Mazza, Tommaso; Meyer, Michael; Serkez, Svitozar [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2017-06-15

    X-ray Free Electron Lasers (XFELs) have been proven to generate short and powerful radiation pulses allowing for a wide class of novel experiments. If an XFEL facility supports the generation of two X-ray pulses with different wavelengths and controllable delay, the range of possible experiments is broadened even further to include X-ray-pump/X-ray-probe applications. In this work we discuss the possibility of applying a simple and cost-effective method for producing two-color pulses at the SASE3 soft X-ray beamline of the European XFEL. The technique is based on the installation of a magnetic chicane in the baseline undulator and can be accomplished in several steps. We discuss the scientific interest of this upgrade for the Small Quantum Systems (SQS) instrument, in connection with the high-repetition rate of the European XFEL, and we provide start-to-end simulations up to the radiation focus on the sample, proving the feasibility of our concept.

  14. Laser-induced plasmas in air studied using two-color interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zefeng; Wu, Jian, E-mail: jxjawj@mail.xjtu.edu.cn; Li, Xingwen; Han, Jiaxun; Jia, Shenli; Qiu, Aici [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Shaanxi 710049 (China); Wei, Wenfu [School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031 (China)

    2016-08-15

    Temporally and spatially resolved density profiles of Cu atoms, electrons, and compressed air, from laser-induced copper plasmas in air, are measured using fast spectral imaging and two-color interferometry. From the intensified CCD images filtered by a narrow-band-pass filter centered at 515.32 nm, the Cu atoms expansion route is estimated and used to determine the position of the fracture surface between the Cu atoms and the air. Results indicate that the Cu atoms density at distances closer to the target (0–0.4 mm) is quite low, with the maximum density appearing at the edge of the plasma's core being ∼4.6 × 10{sup 24 }m{sup −3} at 304 ns. The free electrons are mainly located in the internal region of the plume, which is supposed to have a higher temperature. The density of the shock wave is (4–6) × 10{sup 25 }m{sup −3}, corresponding to air compression of a factor of 1.7–2.5.

  15. Application of kinetic inductance thermometers to x-ray calorimetry

    International Nuclear Information System (INIS)

    Wai, Y.C.; Labov, S.E.; Silver, E.H.

    1990-01-01

    A kinetic inductance thermometer is applied to x-ray calorimetry, and its operation over a wide range of frequencies and geometries is discussed. Three amplifier configurations are described, one using a superconducting quantum interference device (SQUID) amplifier, another incorporating an FET amplifier in an amplitude modulated system, and the third, using a tunnel diode frequency modulated oscillator circuit. The predicted performance of each configuration is presented. 13 refs., 6 figs., 1 tab

  16. Model for cryogenic particle detectors with superconducting phase transition thermometers

    International Nuclear Information System (INIS)

    Proebst, F.; Frank, M.; Cooper, S.; Colling, P.; Dummer, D.; Ferger, P.; Nucciotti, A.; Seidel, W.; Stodolsky, L.

    1994-09-01

    We present data on a detector composed of an 18 g Si crystal and a superconducting phase transition thermometer which could be operated over a wide temperature range. An energy resolution of 1 keV (FWHM) has been obtained for 60 keV photons. The signals consist of two components: A fast one and a slow one, with decay times of 1.5 ms and 30-60 ms, respectively. In this paper we present a simple model which takes thermal and non-thermal phonon processes into account and provides a description of the observed temperature dependence of the pulse shape. The fast component, which completely dominates the signal at low temperatures, is due to high-frequency non-thermal phonons being absorbed in the thermometer. Thermalization of these phonons then leads to a temperature rise of the absorber, which causes the slow thermal component. At the highest operating temperatures (T∼80 mK) the amplitude of the slow component is roughly as expected from the heat capacity of the absorber. The strong suppression of the slow component at low temperatures is explained mostly as a consequence of the weak thermal coupling between electrons and phonons in the thermometer at low temperatures. (orig.)

  17. Radiation Requirements and Testing of Cryogenic Thermometers for the Ilc

    Science.gov (United States)

    Barnett, T.; Filippov, Yu. P.; Filippova, E. Yu.; Mokhov, N. V.; Nakao, N.; Klebaner, A. L.; Korenev, S. A.; Theilacker, J. C.; Trenikhina, J.; Vaziri, K.

    2008-03-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox® and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results.

  18. Radiation requirements and testing of cryogenic thermometers for the ILC

    International Nuclear Information System (INIS)

    Barnett, T.; Filippov, Yu.P.; Mokhov, N.V.; Nakao, N.; Klebaner, A.L.; Korenev, S.A.; Theilacker, J.C.; Trenikhina, J.; Vaziri, K.

    2007-01-01

    Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox(reg s ign) and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results

  19. A nonlinear deformed su(2) algebra with a two-color quasitriangular Hopf structure

    International Nuclear Information System (INIS)

    Bonatsos, D.; Daskaloyannis, C.; Kolokotronis, P.; Ludu, A.; Quesne, C.

    1997-01-01

    Nonlinear deformations of the enveloping algebra of su(2), involving two arbitrary functions of J 0 and generalizing the Witten algebra, were introduced some time ago by Delbecq and Quesne. In the present paper, the problem of endowing some of them with a Hopf algebraic structure is addressed by studying in detail a specific example, referred to as scr(A) q + (1). This algebra is shown to possess two series of (N+1)-dimensional unitary irreducible representations, where N=0,1,2,hor-ellipsis. To allow the coupling of any two such representations, a generalization of the standard Hopf axioms is proposed by proceeding in two steps. In the first one, a variant and extension of the deforming functional technique is introduced: variant because a map between two deformed algebras, su q (2) and scr(A) q + (1), is considered instead of a map between a Lie algebra and a deformed one, and extension because use is made of a two-valued functional, whose inverse is singular. As a result, the Hopf structure of su q (2) is carried over to scr(A) q + (1), thereby endowing the latter with a double Hopf structure. In the second step, the definition of the coproduct, counit, antipode, and scr(R)-matrix is extended so that the double Hopf algebra is enlarged into a new algebraic structure. The latter is referred to as a two-color quasitriangular Hopf algebra because the corresponding scr(R)-matrix is a solution of the colored Yang endash Baxter equation, where the open-quotes colorclose quotes parameters take two discrete values associated with the two series of finite-dimensional representations. copyright 1997 American Institute of Physics

  20. Phase diagram of two-color QCD in a Dyson-Schwinger approach

    Energy Technology Data Exchange (ETDEWEB)

    Buescher, Pascal Joachim

    2014-04-28

    We investigate two-color QCD with N{sub f}=2 at finite temperatures and chemical potentials using a Dyson-Schwinger approach. We employ two different truncations for the quark loop in the gluon DSE: one based on the Hard-Dense/Hard-Thermal Loop (HDTL) approximation of the quark loop and one based on the back-coupling of the full, self-consistent quark propagator (SCQL). We compare results for the different truncations with each other as well as with other approaches. As expected, we find a phase dominated by the condensation of quark-quark pairs. This diquark condensation phase overshadows the critical end point and first-order phase transition which one finds if diquark condensation is neglected. The phase transition from the phase without diquark condensation to the diquark-condensation phase is of second order. We observe that the dressing with massless quarks in the HDTL approximation leads to a significant violation of the Silver Blaze property and to a too small diquark condensate. The SCQL truncation, on the other hand, is found to reproduce all expected features of the μ-dependent quark condensates. Moreover, with parameters adapted to the situation in other approaches, we also find good to very good agreement with model and lattice calculations in all quark quantities. We find indictions that the physics in recent lattice calculations is likely to be driven solely by the explicit chiral symmetry breaking. Discrepancies w.r.t. the lattice are, however, observed in two quantities that are very sensitive to the screening of the gluon propagator, the dressed gluon propagator itself and the phase-transition line at high temperatures.

  1. Tests of a two-color interferometer and polarimeter for ITER density measurements

    Science.gov (United States)

    Van Zeeland, M. A.; Carlstrom, T. N.; Finkenthal, D. K.; Boivin, R. L.; Colio, A.; Du, D.; Gattuso, A.; Glass, F.; Muscatello, C. M.; O'Neill, R.; Smiley, M.; Vasquez, J.; Watkins, M.; Brower, D. L.; Chen, J.; Ding, W. X.; Johnson, D.; Mauzey, P.; Perry, M.; Watts, C.; Wood, R.

    2017-12-01

    A full-scale 120 m path length ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been constructed and undergone initial testing at General Atomics. In the TIP prototype, two-color interferometry is carried out at 10.59 μm and 5.22 μm using a CO2 and quantum cascade laser (QCL) respectively while a separate polarimetry measurement of the plasma induced Faraday effect is made at 10.59 μm. The polarimeter system uses co-linear right and left-hand circularly polarized beams upshifted by 40 and 44 MHz acousto-optic cells respectively, to generate the necessary beat signal for heterodyne phase detection, while interferometry measurements are carried out at both 40 MHz and 44 MHz for the CO2 laser and 40 MHz for the QCL. The high-resolution phase information is obtained using an all-digital FPGA based phase demodulation scheme and precision clock source. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system responsible for minimizing noise in the measurement and keeping the TIP diagnostic aligned indefinitely on its 120 m beam path including as the ITER vessel is brought from ambient to operating temperatures. The prototype beam path incorporates translation stages to simulate ITER motion through a bake cycle as well as other sources of motion or misalignment. Even in the presence of significant motion, the TIP prototype is able to meet ITER’s density measurement requirements over 1000 s shot durations with demonstrated phase resolution of 0.06° and 1.5° for the polarimeter and vibration compensated interferometer respectively. TIP vibration compensated interferometer measurements of a plasma have also been made in a pulsed radio frequency device and show a line-integrated density resolution of δ {nL}=3.5× {10}17 m-2.

  2. On the chiral perturbation theory for two-flavor two-color QCD at finite chemical potential

    Czech Academy of Sciences Publication Activity Database

    Brauner, Tomáš

    2006-01-01

    Roč. 21, č. 7 (2006), s. 559-569 ISSN 0217-7323 R&D Projects: GA ČR(CZ) GD202/05/H003 Institutional research plan: CEZ:AV0Z10480505 Keywords : two-color QCD * chiral perturbation theory * chemical potential Subject RIV: BE - Theoretical Physics Impact factor: 1.564, year: 2006

  3. High-Temperature Compatible Nickel Silicide Thermometer And Heater For Catalytic Chemical Microreactors

    DEFF Research Database (Denmark)

    Jensen, Søren; Quaade, U.J.; Hansen, Ole

    2005-01-01

    Integration of heaters and thermometers is important for agile and accurate control and measurement of the thermal reaction conditions in microfabricated chemical reactors (microreactors). This paper describes development and operation of nickel silicide heaters and temperature sensors...... for temperatures exceeding 700 °C. The heaters and thermometers are integrated with chemical microreactors for heterogeneous catalytic conversion of gasses, and thermally activated catalytic conversion of CO to CO2 in the reactors is demonstrated. The heaters and thermometers are shown to be compatible...

  4. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].

    Science.gov (United States)

    Padilla-Raygoza, Nicolás; Ruiz-Paloalto, M Laura; Díaz-Guerrero, Rosalina; Olvera-Villanueva, Georgina; Maldonado, Angélica; Raygoza-Mendoza, María Del Pilar

    2014-01-01

    To compare body temperature measurements using tympanic, skin and digital axillary thermometers. Hospitalized or outpatient children from the General Hospital Celaya, ISSSTE Hospital Clinic and General Hospital No. 4 IMSS, and the pediatric private service in Celaya, Guanajuato, from 1 day of life until 16 years old, were recruited over a one month period, after their parents signed the consent form. The order of each institution was selected by simple randomization. Body temperatures were measured in triplicate using tympanic, skin and digital axillary thermometers. The sample consisted of 554 children. The Pearson r between the tympanic and digital axillary thermometers was 0.57 to 0.65, with a positive linear relationship (P<.05); between the skin and the digital axillary thermometers, it was between 0.47 and 0.52 with a positive linearrelationship (P<.05). The intra-observer Kappa for the tympanic thermometer was 0.86, and for the inter-observer was 0.77; for the skin thermometer it was 0.82 and 0.67, respectively, and for the digital axillary thermometer it was 0.86 for intra-observer reliability and 0.78 for inter -observer reliability. Tympanic and axillary thermometers showed better precision in measuring the body temperature in children than skin thermometers. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  5. Rovibronically selected and resolved two-color laser photoionization and photoelectron study of cobalt carbide cation.

    Science.gov (United States)

    Huang, Huang; Chang, Yih Chung; Luo, Zhihong; Shi, Xiaoyu; Lam, Chow-Shing; Lau, Kai-Chung; Ng, C Y

    2013-03-07

    We have conducted a two-color visible-ultraviolet (VIS-UV) resonance-enhanced laser photoionization efficiency and pulsed field ionization-photoelectron (PFI-PE) study of gaseous cobalt carbide (CoC) near its ionization onset in the total energy range of 61,200-64,510 cm(-1). The cold gaseous CoC sample was prepared by a laser ablation supersonically cooled beam source. By exciting CoC molecules thus generated to single N' rotational levels of the intermediate CoC∗((2)Σ(+); v') state using a VIS dye laser prior to UV laser photoionization, we have obtained N(+) rotationally resolved PFI-PE spectra for the CoC(+)(X(1)Σ(+); v(+) = 0 and 1) ion vibrational bands free from interference by impurity species except Co atoms produced in the ablation source. The rotationally selected and resolved PFI-PE spectra have made possible unambiguous rotational assignments, yielding accurate values for the adiabatic ionization energy of CoC(X(2)Σ(+)), IE(CoC) = 62,384.3 ± 0.6 cm(-1) (7.73467 ± 0.00007 eV), the vibrational frequency ωe (+) = 985.6 ± 0.6 cm(-1), the anharmonicity constant ωe (+)χe (+) = 6.3 ± 0.6 cm(-1), the rotational constants (Be (+) = 0.7196 ± 0.0005 cm(-1), αe (+) = 0.0056 ± 0.0008 cm(-1)), and the equilibrium bond length re (+) = 1.534 Å for CoC(+)(X(1)Σ(+)). The observation of the N(+) = 0 level in the PFI-PE measurement indicates that the CoC(+) ground state is of (1)Σ(+) symmetry. Large ΔN(+) = N(+) - N' changes up to 6 are observed for the photoionization transitions CoC(+)(X(1)Σ(+); v(+) = 0-2; N(+)) ← CoC∗((2)Σ(+); v'; N' = 6, 7, 8, and 9). The highly precise energetic and spectroscopic data obtained in the present study have served as a benchmark for testing theoretical predictions based on state-of-the-art ab initio quantum calculations at the CCSDTQ∕CBS level of theory as presented in the companion article.

  6. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively

  7. Gamma thermometer allowing absolute and differential temperature measurements

    International Nuclear Information System (INIS)

    Bottin, P.; Schley, R.

    1985-01-01

    The gamma thermometer comprises an external envelope containing a cylindrical rod with a central bore and, thick and thin parts defining insulating chambers, at least one thermocouple set in the said central bore; the thermocouple has three junctions connected to one of their end parts by a junction at the level of a thin part, while one at least of the wires comprises two elements made of different materials connected by a junction at the level of a thick part. The present invention applies more particularly for detecting level of the coolant in a nuclear reactor [fr

  8. Optical Fiber Thermometer Based on Fiber Bragg Gratings

    Science.gov (United States)

    Rosli, Ekbal Bin; Mohd. Noor, Uzer

    2018-03-01

    Fiber Bragg grating has generated much interest in use as sensors to measure strain, temperature, and other physical parameters. It also the most common component used to develop this sensor with the advantages of simple, intrinsic sensing elements, electrically passive operation, EMI immunity, high sensitivity, compact size and potentially low cost [6]. This paper reports the design of an optical fiber thermometer based on fiber Bragg gratings. The system was developed for detecting temperature and strain by monitoring the shift of Bragg wavelength. The shifting of Bragg wavelength is used to indicate the temperature and strain due to the change in the surrounding temperature and strain. When the temperature and strain reach the exact wavelength level of the system, the temperature and strain value will display on the Arduino liquid crystal display (LCD). The optical fiber will provide the broadband light source and after passing the FBG the Bragg wavelength into the optical spectrum analyzer (OSA). The system is based on FBG as a physical quantity sensor. The temperatures measured is taken from the water bath and that of the strain is provided by amount of slotted mass used. The outcome of this project is to characterize the Bragg wavelength shifting from the fiber Bragg grating output. As the conclusion, this project provides an efficient optical fiber thermometer in measuring temperature and strain in order to replace the use of conventional electrical instruments.

  9. Polarimetric, Two-Color, Photon-Counting Laser Altimeter Measurements of Forest Canopy Structure

    Science.gov (United States)

    Harding, David J.; Dabney, Philip W.; Valett, Susan

    2011-01-01

    Laser altimeter measurements of forest stands with distinct structures and compositions have been acquired at 532 nm (green) and 1064 nm (near-infrared) wavelengths and parallel and perpendicular polarization states using the Slope Imaging Multi-polarization Photon Counting Lidar (SIMPL). The micropulse, single photon ranging measurement approach employed by SIMPL provides canopy structure measurements with high vertical and spatial resolution. Using a height distribution analysis method adapted from conventional, 1064 nm, full-waveform lidar remote sensing, the sensitivity of two parameters commonly used for above-ground biomass estimation are compared as a function of wavelength. The results for the height of median energy (HOME) and canopy cover are for the most part very similar, indicating biomass estimations using lidars operating at green and near-infrared wavelengths will yield comparable estimates. The expected detection of increasing depolarization with depth into the canopies due to volume multiple-scattering was not observed, possibly due to the small laser footprint and the small detector field of view used in the SIMPL instrument. The results of this work provide pathfinder information for NASA's ICESat-2 mission that will employ a 532 nm, micropulse, photon counting laser altimeter.

  10. Two-color single-photon emission from InAs quantum dots: toward logic information management using quantum light.

    Science.gov (United States)

    Rivas, David; Muñoz-Matutano, Guillermo; Canet-Ferrer, Josep; García-Calzada, Raúl; Trevisi, Giovanna; Seravalli, Luca; Frigeri, Paola; Martínez-Pastor, Juan P

    2014-02-12

    In this work, we propose the use of the Hanbury-Brown and Twiss interferometric technique and a switchable two-color excitation method for evaluating the exciton and noncorrelated electron-hole dynamics associated with single photon emission from indium arsenide (InAs) self-assembled quantum dots (QDs). Using a microstate master equation model we demonstrate that our single QDs are described by nonlinear exciton dynamics. The simultaneous detection of two-color, single photon emission from InAs QDs using these nonlinear dynamics was used to design a NOT AND logic transference function. This computational functionality combines the advantages of working with light/photons as input/output device parameters (all-optical system) and that of a nanodevice (QD size of ∼ 20 nm) while also providing high optical sensitivity (ultralow optical power operational requirements). These system features represent an important and interesting step toward the development of new prototypes for the incoming quantum information technologies.

  11. Two-color pump-probe laser spectroscopy instrument with picosecond time-resolved electronic delay and extended scan range

    Science.gov (United States)

    Yu, Anchi; Ye, Xiong; Ionascu, Dan; Cao, Wenxiang; Champion, Paul M.

    2005-11-01

    An electronically delayed two-color pump-probe instrument was developed using two synchronized laser systems. The instrument has picosecond time resolution and can perform scans over hundreds of nanoseconds without the beam divergence and walk-off effects that occur using standard spatial delay systems. A unique picosecond Ti :sapphire regenerative amplifier was also constructed without the need for pulse stretching and compressing optics. The picosecond regenerative amplifier has a broad wavelength tuning range, which suggests that it will make a significant contribution to two-color pump-probe experiments. To test this instrument we studied the rotational correlation relaxation of myoglobin (τr=8.2±0.5ns) in water as well as the geminate rebinding kinetics of oxygen to myoglobin (kg1=1.7×1011s-1, kg2=3.4×107s-1). The results are consistent with, and improve upon, previous studies.

  12. Compact 6 dB Two-Color Continuous Variable Entangled Source Based on a Single Ring Optical Resonator

    Directory of Open Access Journals (Sweden)

    Ning Wang

    2018-02-01

    Full Text Available Continuous-variable entangled optical beams at the degenerate wavelength of 0.8 μm or 1.5 μm have been investigated extensively, but separately. The two-color entangled states of these two useful wavelengths, with sufficiently high degrees of entanglement, still lag behind. In this work, we analyze the various limiting factors that affect the entanglement degree. On the basis of this, we successfully achieve 6 dB of two-color quadrature entangled light beams by improving the escape efficiency of the nondegenerate optical amplifier, the stability of the phase-locking servo system, and the detection efficiency. Our entangled source is constructed only from a single ring optical resonator, and thus is highly compact, which is suitable for applications in long-distance quantum communication networks.

  13. Chemical reactivation of resin-embedded pHuji adds red for simultaneous two-color imaging with EGFP

    Science.gov (United States)

    Guo, Wenyan; Liu, Xiuli; Liu, Yurong; Gang, Yadong; He, Xiaobin; Jia, Yao; Yin, Fangfang; Li, Pei; Huang, Fei; Zhou, Hongfu; Wang, Xiaojun; Gong, Hui; Luo, Qingming; Xu, Fuqiang; Zeng, Shaoqun

    2017-01-01

    The pH-sensitive fluorescent proteins enabling chemical reactivation in resin are useful tools for fluorescence microimaging. EGFP or EYFP is good for such applications. For simultaneous two-color imaging, a suitable red fluorescent protein is an urgent need. Here a pH-sensitive red fluorescent protein, pHuji, is selected and verified to remain pH-sensitive in HM20 resin. We observe 183% fluorescence intensity of pHuji in resin-embeded mouse brain and 29.08-fold fluorescence intensity of reactivated pHuji compared to the quenched state. pHuji and EGFP can be quenched and chemically reactivated simultaneously in resin, thus enabling simultaneous two-color micro-optical sectioning tomography of resin-embedded mouse brain. This method may greatly facilitate the visualization of neuronal morphology and neural circuits to promote understanding of the structure and function of the brain. PMID:28717566

  14. Density profiles of small Dirac operator eigenvalues for two color QCD at nonzero chemical potential compared to matrix models

    OpenAIRE

    Akemann, G; Bittner, E; Lombardo, M; Markum, H; Pullirsch, R

    2004-01-01

    We investigate the eigenvalue spectrum of the staggered Dirac matrix in two color QCD at finite chemical potential. The profiles of complex eigenvalues close to the origin are compared to a complex generalization of the chiral Gaussian Symplectic Ensemble, confirming its predictions for weak and strong non-Hermiticity. They differ from the QCD symmetry class with three colors by a level repulsion from both the real and imaginary axis.

  15. Density profiles of small Dirac operator eigenvalues for two color QCD at nonzero chemical potential compared to matrix models

    International Nuclear Information System (INIS)

    Akemann, Gernot; Bittner, Elmar; Lombardo, Maria-Paola; Markum, Harald; Pullirsch, Rainer

    2005-01-01

    We investigate the eigenvalue spectrum of the staggered Dirac matrix in two color QCD at finite chemical potential. The profiles of complex eigenvalues close to the origin are compared to a complex generalization of the chiral Gaussian Symplectic Ensemble, confirming its predictions for weak and strong non-Hermiticity. They differ from the QCD symmetry class with three colors by a level repulsion from both the real and imaginary axis

  16. Demonstrating the Temperature Dependence of Density via Construction of a Galilean Thermometer

    Science.gov (United States)

    Priest, Marie A.; Padgett, Lea W.; Padgett, Clifford W.

    2011-01-01

    A method for the construction of a Galilean thermometer out of common chemistry glassware is described. Students in a first-semester physical chemistry (thermodynamics) class can construct the Galilean thermometer as an investigation of the thermal expansivity of liquids and the temperature dependence of density. This is an excellent first…

  17. 27 CFR 30.23 - Use of precision hydrometers and thermometers.

    Science.gov (United States)

    2010-04-01

    ... hydrometers and thermometers. 30.23 Section 30.23 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO... Use of precision hydrometers and thermometers. Care should be exercised to obtain accurate hydrometer... entire quantity. The hydrometers should be kept clean and free of any oily substance. Immediately before...

  18. The design of two color interferometer system for the 3-dimensional analysis of plasma density evolution on KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.C., E-mail: kclee@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Juhn, J.-W.; Nam, Y.U.; Kim, Y.S.; Wi, H.M. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Kim, S.W.; Ghim, Y.-C. [Korea Advanced Institute of Science and Technology, Daejeon 34141 (Korea, Republic of)

    2016-12-15

    Highlights: • A Two Color Interferometer (TCI) system is designed for 3-D measurement of KSTAR. • TCI is consists of 10.6 μm CO2 laser and 0.63 μm HeNe laser with tangential 5 channels. • 2 channels are installed in 2016 and 5 channel operation is planned in 2017. - Abstract: A 5-channel two color interferometer (TCI) system has been designed on KSTAR. TCI system is designed for tangential beam paths, which will combine with two existing interferometer systems of vertical and radial beam paths, so that it will provide 3-dimensional measurement of electron density evolution. TCI system uses wavelengths of 10.6 μm by a CO{sub 2} laser and 0.633 μm by a HeNe laser. The system compensates the vibrational noise by using two colors and avoids refraction by short wavelengths. The main purpose of the TCI is to generate routine measurement of the line integrated plasma density for the real time density control on KSTAR. The 5-channels will provide profile data for the density. Time resolution of the system is expected to be 500 kHz or higher in order to measure 3-dimensional density fluctuations for ELMs and other MHD activities including TAE modes. The system is planned to be working on KSTAR 2016 campaign with 1–2 channels.

  19. Imaging of particles with 3D full parallax mode with two-color digital off-axis holography

    Science.gov (United States)

    Kara-Mohammed, Soumaya; Bouamama, Larbi; Picart, Pascal

    2018-05-01

    This paper proposes an approach based on two orthogonal views and two wavelengths for recording off-axis two-color holograms. The approach permits to discriminate particles aligned along the sight-view axis. The experimental set-up is based on a double Mach-Zehnder architecture in which two different wavelengths provides the reference and the object beams. The digital processing to get images from the particles is based on convolution so as to obtain images with no wavelength dependence. The spatial bandwidth of the angular spectrum transfer function is adapted in order to increase the maximum reconstruction distance which is generally limited to a few tens of millimeters. In order to get the images of particles in the 3D volume, a calibration process is proposed and is based on the modulation theorem to perfectly superimpose the two views in a common XYZ axis. The experimental set-up is applied to two-color hologram recording of moving non-calibrated opaque particles with average diameter at about 150 μm. After processing the two-color holograms with image reconstruction and view calibration, the location of particles in the 3D volume can be obtained. Particularly, ambiguity about close particles, generating hidden particles in a single-view scheme, can be removed to determine the exact number of particles in the region of interest.

  20. Generation of an isolated sub-30 attosecond pulse in a two-color laser field and a static electric field

    International Nuclear Information System (INIS)

    Zhang Gang-Tai; Zhang Mei-Guang; Bai Ting-Ting

    2012-01-01

    We theoretically investigate high-order harmonic generation (HHG) from a helium ion model in a two-color laser field, which is synthesized by a fundamental pulse and its second harmonic pulse. It is shown that a supercontinuum spectrum can be generated in the two-color field. However, the spectral intensity is very low, limiting the application of the generated attosecond (as) pulse. By adding a static electric field to the synthesized two-color field, not only is the ionization yield of electrons contributing to the harmonic emission remarkably increased, but also the quantum paths of the HHG can be significantly modulated. As a result, the extension and enhancement of the supercontinuum spectrum are achieved, producing an intense isolated 26-as pulse with a bandwidth of about 170.5 eV. In particular, we also analyse the influence of the laser parameters on the ultrabroad supercontinuum spectrum and isolated sub-30-as pulse generation. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  1. The design of two color interferometer system for the 3-dimensional analysis of plasma density evolution on KSTAR

    International Nuclear Information System (INIS)

    Lee, K.C.; Juhn, J.-W.; Nam, Y.U.; Kim, Y.S.; Wi, H.M.; Kim, S.W.; Ghim, Y.-C.

    2016-01-01

    Highlights: • A Two Color Interferometer (TCI) system is designed for 3-D measurement of KSTAR. • TCI is consists of 10.6 μm CO2 laser and 0.63 μm HeNe laser with tangential 5 channels. • 2 channels are installed in 2016 and 5 channel operation is planned in 2017. - Abstract: A 5-channel two color interferometer (TCI) system has been designed on KSTAR. TCI system is designed for tangential beam paths, which will combine with two existing interferometer systems of vertical and radial beam paths, so that it will provide 3-dimensional measurement of electron density evolution. TCI system uses wavelengths of 10.6 μm by a CO 2 laser and 0.633 μm by a HeNe laser. The system compensates the vibrational noise by using two colors and avoids refraction by short wavelengths. The main purpose of the TCI is to generate routine measurement of the line integrated plasma density for the real time density control on KSTAR. The 5-channels will provide profile data for the density. Time resolution of the system is expected to be 500 kHz or higher in order to measure 3-dimensional density fluctuations for ELMs and other MHD activities including TAE modes. The system is planned to be working on KSTAR 2016 campaign with 1–2 channels.

  2. Low-temperature thermometry. Use of a gas thermometer as a calibration standard between 4 and 300 K

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1978-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300 K may be obtained. After some words about low temperature thermometry, the gas thermometer and its auxiliary equipment are described briefly; the corrections to be applied to the results are given and the article ends with a table showing the values obtained [fr

  3. Designing a TAC thermometer from a VHTR graphite structure

    Energy Technology Data Exchange (ETDEWEB)

    Smith, James A., E-mail: James.Smith@INL.gov; Kotter, Dale, E-mail: James.Smith@INL.gov [Fuel Performance and Design, Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Garrett, Steven L.; Ali, Randall A. [Graduate Program in Acoustics, Penn State University, State College, PA (United States)

    2015-03-31

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. Very High Temperature Reactors are pushing the in core temperatures even higher. A unique sensing approach will be discussed to address the necessary high temperature measurements. Thermoacoustic thermometry exploits high temperatures and uses materials that are immune to the effects of ionizing radiation to create a temperature sensor that is self-powered and wireless. In addition, the form-factor for the Thermoacoustic Thermometer (TACT) can be designed to be integrated within common in-pile structures. There are no physical moving parts required for TACT and the sensor is self-powered, as it uses the nuclear fuel for its heat source. TACT data will be presented from a laboratory prototype mimicking the design necessary for a VHTR graphite structure.

  4. Performance of Magnetic Penetration Thermometers for X-Ray Astronomy

    Science.gov (United States)

    Nagler, P. C.; Adams, J. S.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Hsieh, W. T.; Kelly, D. P.; Porst, J. P.; Sadleir, J. E.; Seidel, G. M.; hide

    2012-01-01

    The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than leV FWHM for energies up to 10 keY. We have microfabricated and characterized thin-film magnetic penetration thermometers (MPTs) that show great promise towards meeting these capabilities. MPTs operate in similar fashion to metallic magnetic calorimeters (MMCs), except that a superconducting sensor takes the place of a paramagnetic sensor and it is the temperature dependence of the superconductor's diamagnetic response that provides the temperature sensitivity. We present a description of the design and performance of our prototype thin-film MPTs with MoAu bilayer sensors, which have demonstrated an energy resolution of approx 2 eV FWHM at 1.5 keY and 4.3 eV FWHM at 5.9 keY.

  5. The distress thermometer in survivors of gynaecological cancer

    DEFF Research Database (Denmark)

    Olesen, Mette L.; Hansen, Merete K.; Hansson, Helena

    2017-01-01

    Purpose: Unrecognised psychological distress among cancer survivors may be identified using short screening tools. We validated the accuracy of the distress thermometer (DT) to detect psychological distress on the Hospital Anxiety and Depression Scale (HADS) among early stage gynaecological cancer...... survivors and whether the women’s DT and HADS scores were associated with the need of an individualised supportive intervention. Methods: One hundred sixty-five gynaecological cancer survivors answered DT and HADS before randomisation in a trial testing a nurse-led, person-centred intervention using...... supportive conversations. The number of conversations was decided in the woman-nurse dyad based on the woman’s perceived need. Nurses were unaware of the women’s DT and HADS scores. We validated DT’s accuracy for screening using HADS as gold standard and receiver operating characteristic curves. Associations...

  6. Radiation stability of low-temperature resistance thermometers

    International Nuclear Information System (INIS)

    Neklyudov, I.M.; Petrusenko, Yu.T.; Sleptsov, A.N.; Logvinenko, S.P.; Mikhina, G.F.; Rossoshanskij, O.A.

    1989-01-01

    The effect of low temperature (∼ 5 and 11 K) irradiation with E=30 MeV electrons and the subsequent annealing at 180 and 300 K on gauge dependences R(T) of resistance thermometers (RT) on the basis of p-GaAs, Ni and In is investigated. For GaAs-RT the dependence of electroresistance R(4.2 K) on the irradiation fluence is shown to be non monotonic. The annealing at 180 and 300 K does not restore GaAs-RT thermometric characteristics but it leads to their further degradation. The annealing of Ni and In irradiated RT's at T>180 K leads to total restoring of their electrophysical properties. 16 refs.; 5 figs.; 1 tab

  7. Subharmonic frequency locking in the resistive Josephson thermometer

    International Nuclear Information System (INIS)

    van Veldhuizen, M.; Fowler, H.A.

    1985-01-01

    Phase-locked oscillatory solutions are examined as a basis for the dc impedance of the resistive superconducting quantum-interference device Josephson thermometer. The calculations are based on the resistively shunted junction model in the limit 2πL/sub s/I/sub c//Phi 0 > or =1, where L/sub s/ is the loop inductance and I/sub c/ is the junction critical current, and for a junction resistance large compared with the external shunt resistance. An algorithm for representing frequency entrainment in (kappa,ω) space (drive amplitude, frequency) leads to zones with rotation number p/q having the form of leaf-shaped regions joined and overlapping at their tips. High-resonance zones are very thin and locally similar. No chaotic behavior has been observed. The model can simulate the ''rising'' curves of dc impedance as a function of drive amplitude

  8. History of infrared detectors

    Science.gov (United States)

    Rogalski, A.

    2012-09-01

    This paper overviews the history of infrared detector materials starting with Herschel's experiment with thermometer on February 11th, 1800. Infrared detectors are in general used to detect, image, and measure patterns of the thermal heat radiation which all objects emit. At the beginning, their development was connected with thermal detectors, such as thermocouples and bolometers, which are still used today and which are generally sensitive to all infrared wavelengths and operate at room temperature. The second kind of detectors, called the photon detectors, was mainly developed during the 20th Century to improve sensitivity and response time. These detectors have been extensively developed since the 1940's. Lead sulphide (PbS) was the first practical IR detector with sensitivity to infrared wavelengths up to ˜3 μm. After World War II infrared detector technology development was and continues to be primarily driven by military applications. Discovery of variable band gap HgCdTe ternary alloy by Lawson and co-workers in 1959 opened a new area in IR detector technology and has provided an unprecedented degree of freedom in infrared detector design. Many of these advances were transferred to IR astronomy from Departments of Defence research. Later on civilian applications of infrared technology are frequently called "dual-use technology applications." One should point out the growing utilisation of IR technologies in the civilian sphere based on the use of new materials and technologies, as well as the noticeable price decrease in these high cost technologies. In the last four decades different types of detectors are combined with electronic readouts to make detector focal plane arrays (FPAs). Development in FPA technology has revolutionized infrared imaging. Progress in integrated circuit design and fabrication techniques has resulted in continued rapid growth in the size and performance of these solid state arrays.

  9. Evaluation of flow-induced vibration of thermometer well for JOYO

    International Nuclear Information System (INIS)

    Isozaki, Kazunori; Tomita, Naoki

    1997-05-01

    Sodium leak accident of MONJU was caused high cycles fatigue damage of thermometer well by flow-induced vibration. It was due to the symmetric vortex shedding which was occurred rear flow of thermometer well. So, Thermometer wells installed in primary and secondary heat transport systems of JOYO were evaluated of flow-induced vibration. Evaluation of flow-induced vibration of thermometer well was done checking of flow-induced vibration base on authorized design report for JOYO, evaluation of summary flow-induced vibration by natural frequency of thermometer well in sodium as cantilever models, and evaluation based on small velocity rule of ASME Code Section III Appendix N-1300. By this result, thermometer wells (12B piping of secondary cooling system) were not satisfied requirement to avoid flow-induced vibration by small velocity rule. Therefore, Detailed vibration characteristic analysis, water flow-induced vibration test, dumping test and evaluation of structural integrity were carried out. These results, vibration amplitude of well on the tip was 0.13 mm (vibration non-dimensional amplitude of 0.015) and peak stress of 2.9 kg/mm 2 is occurred. Thermometer wells (12B piping of secondary cooling system) which occurred peak stress by flow vibration was confirmed enough to satisfy 5.3 kg/mm 2 of design fatigue limit. (author)

  10. Semiconductor resistance thermometer for the temperature range 300-0.3 K

    International Nuclear Information System (INIS)

    Zinov'eva, K.N.; Zarubin, L.I.; Nemish, I.Yu.; Vorobkalo, F.M.; Boldarev, S.T.; AN Ukrainskoj SSR, Kiev. Inst. Poluprovodnikov)

    1979-01-01

    Thermometric characteristics of semiconductor resistor thermometers for the temperature range from 300 to 0.3 K and from 77 to 0.3 K are given. Temperature dependence of thermometer resistances in the 300-1.3 K range was measured in cryostats with pumping-out of N 2 , H 2 and 4 He. For measurements below 1.3 K use was made of a 3 H- 4 He dissolving cryostat. The accuracy of measuring temperatures in the 1.3-0.3 K range is not below +-0.003 K, the error in determining thermometer resistances does not exceed 1%. The analysis of obtained thermometric characteristics of several series of semiconductor resistance thermometers showed that observed insignificant spread of resistances of thermometers in one series and identity of characteristics allows them to be used without preliminary calibration for relatively coarse measurements in the range from 3O0 to 0.3 K. Besides, it has been found that in the 4.2-0.3 K range the thermometric characteristics represent a straight line in the lgR-Tsup(-n) coordinates, where R is the thermometer resistance, T is the temperature and n=0.5. Thus, the thermometers of the same series can be calibrated only in 2 or 3 reference point measurements

  11. Optical trapping of cold neutral atoms using a two-color evanescent light field around a carbon nanotube

    International Nuclear Information System (INIS)

    Nga, Do Thi; Viet, Nguyen Ai; Nga, Dao Thi Thuy; Lan, Nguyen Thi Phuong

    2014-01-01

    We suggest a new schema of trapping cold atoms using a two-color evanescent light field around a carbon nanotube. The two light fields circularly polarized sending through a carbon nanotube generates an evanescent wave around this nanotube. By evanescent effect, the wave decays away from the nanotube producing a set of trapping minima of the total potential in the transverse plane as a ring around the nanotube. This schema allows capture of atoms to a cylindrical shell around the nanotube. We consider some possible boundary conditions leading to the non-trivial bound state solution. Our result will be compared to some recent trapping models and our previous trapping models.

  12. Simulation of Far-Field Superresolution Fluorescence Imaging with Two-Color One-Photon Excitation of Reversible Photoactivatable Protein

    International Nuclear Information System (INIS)

    Wang Chen; Qiao Ling-Ling; Mao Zheng-Le

    2011-01-01

    We propose to achieve far-field super-resolution imaging by using offset two-color one-photon (2C1P) excitation of reversible photoactivatable fluorescence proteins. Due to the distinctive photoswitching performance of the proteins, such as dronpa, the fluorescence emission will only come from the overlapped region of activation beam and excitation beam. The analysis solution of rate equation shows that the resolution of offset 2C1P microscope is 'engineered' by laser power of excitation and activation beams and the power ratio between them. Superior lateral and transverse resolution is theoretically demonstrated compared with conventional fluorescence scanning microscopy. (fundamental areas of phenomenology(including applications))

  13. Stimulated emission pumping of NH in flames by using two-color resonant four-wave mixing

    Energy Technology Data Exchange (ETDEWEB)

    Radi, P P; Frey, H M; Mischler, B; Tzannis, A P; Beaud, P; Gerber, T [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    In this work we examine the analytical potential of two-color resonant four-wave mixing for the determination and characterization of trace elements in a combustion environment. Experimental results for NH in flames at atmospheric pressure are presented. The selectivity of the technique is used to simplify the Q-branch region of the (0-0)A{sup 3}{Pi}-X{sup 3}{Sigma} vibronic transition of NH. In addition, we demonstrate that the technique is sensitive to state changing collisions. (author) 2 figs., 5 refs.

  14. Observations of strain accumulation across the san andreas fault near palmdale, california, with a two-color geodimeter.

    Science.gov (United States)

    Langbein, J O; Linker, M F; McGarr, A; Slater, L E

    1982-12-17

    Two-color laser ranging measurements during a 15-month period over a geodetic network spanning the San Andreas fault near Palmdale, California, indicate that the crust expands and contracts aseismically in episodes as short as 2 weeks. Shear strain parallel to the fault has accumulated monotonically since November 1980, but at a variable rate. Improvements in measurement precision and temporal resolution over those of previous geodetic studies near Palmdale have resulted in the definition of a time history of crustal deformation that is much more complex than formerly realized.

  15. Distilling two-center-interference information during tunneling of aligned molecules with orthogonally polarized two-color laser fields

    Science.gov (United States)

    Gao, F.; Chen, Y. J.; Xin, G. G.; Liu, J.; Fu, L. B.

    2017-12-01

    When electrons tunnel through a barrier formed by the strong laser field and the two-center potential of a diatomic molecule, a double-slit-like interference can occur. However, this interference effect can not be probed directly right now, as it is strongly coupled with other dynamical processes during tunneling. Here, we show numerically and analytically that orthogonally polarized two-color (OTC) laser fields are capable of resolving the interference effect in tunneling, while leaving clear footprints of this effect in photoelectron momentum distributions. Moreover, this effect can be manipulated by changing the relative field strength of OTC fields.

  16. Stability of High Temperature Standard Platinum Resistance Thermometers at High Temperatures

    OpenAIRE

    Y. A. ABDELAZIZ; F. M. MEGAHED

    2010-01-01

    An investigation of the stability of high temperature standard platinum resistance thermometers HTSPRTs has been carried out for two different designs thermometers (with nominal resistance 0.25 Ω and 2.5 Ω) from two different suppliers. The thermometers were heated for more than 160 hours at temperatures above 960 0C using a vertical furnace with a ceramic block. A study was made of the influence of the heat treatment on the stability of the resistance at the triple point of water, and on the...

  17. Terahertz radiation driven by two-color laser pulses at near-relativistic intensities: Competition between photoionization and wakefield effects

    Science.gov (United States)

    González de Alaiza Martínez, P.; Davoine, X.; Debayle, A.; Gremillet, L.; Bergé, L.

    2016-01-01

    We numerically investigate terahertz (THz) pulse generation by linearly-polarized, two-color femtosecond laser pulses in highly-ionized argon. Major processes consist of tunneling photoionization and ponderomotive forces associated with transverse and longitudinal field excitations. By means of two-dimensional particle-in-cell (PIC) simulations, we reveal the importance of photocurrent mechanisms besides transverse and longitudinal plasma waves for laser intensities >1015 W/cm2. We demonstrate the following. (i) With two-color pulses, photoionization prevails in the generation of GV/m THz fields up to 1017 W/cm2 laser intensities and suddenly loses efficiency near the relativistic threshold, as the outermost electron shell of ionized Ar atoms has been fully depleted. (ii) PIC results can be explained by a one-dimensional Maxwell-fluid model and its semi-analytical solutions, offering the first unified description of the main THz sources created in plasmas. (iii) The THz power emitted outside the plasma channel mostly originates from the transverse currents. PMID:27255689

  18. Multistabilities and symmetry-broken one-color and two-color states in closely coupled single-mode lasers.

    Science.gov (United States)

    Clerkin, Eoin; O'Brien, Stephen; Amann, Andreas

    2014-03-01

    We theoretically investigate the dynamics of two mutually coupled, identical single-mode semi-conductor lasers. For small separation and large coupling between the lasers, symmetry-broken one-color states are shown to be stable. In this case the light outputs of the lasers have significantly different intensities while at the same time the lasers are locked to a single common frequency. For intermediate coupling we observe stable symmetry-broken two-color states, where both lasers lase simultaneously at two optical frequencies which are separated by up to 150 GHz. Using a five-dimensional model, we identify the bifurcation structure which is responsible for the appearance of symmetric and symmetry-broken one-color and two-color states. Several of these states give rise to multistabilities and therefore allow for the design of all-optical memory elements on the basis of two coupled single-mode lasers. The switching performance of selected designs of optical memory elements is studied numerically.

  19. High-order harmonic generation spectra and isolated attosecond pulse generation with a two-color time delayed pulse

    International Nuclear Information System (INIS)

    Feng Liqiang; Chu Tianshu

    2012-01-01

    Highlights: ► Investigation of HHG spectra and single isolated attosecond pulse generation. ► Irradiation from a model Ne atom by two-color time delayed pulse. ► Observation of time delay effect and relative phase effect. ► Revelation of the optimal condition for generating isolated attosecond pulse. ► Generation of a single isolated attosecond pulse of 45as. - Abstract: In this paper, we theoretically investigate the delay time effect on the high-order harmonic generation (HHG) when a model Ne atom is exposed to a two-color time delayed pulse, consisting of a 5fs/800 nm fundamental field and a 20fs/2000 nm controlling field. It shows that the HHG spectra are strongly sensitive to the delay time between the two laser fields, in particular, for the zero carrier-envelope phase (CEP) φ case (corresponding to the 800 nm fundamental field), the maximum cutoff energy has been achieved at zero delay time. However, with the introduction of the CEP (φ = 180°), the delay effect on HHG is changed, exhibiting a ‘U’ structure harmonic emission from −1 T to 1 T. In addition, the combinations of different controlling pulse frequencies and pulse intensities have also been considered, showing the similar results as the original controlling field case, but with some characteristics. Finally, by properly superposing the optimal harmonic spectrum, an isolated 45as pulse is generated without phase compensation.

  20. Cause elucidation of sodium leakage incident at `Monju` reactor. Vibration of thermometer due to fluid force

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Koji; Wada, Yusaku; Morishita, Masaki; Yamaguchi, Akira; Ichimiya, Masakazu [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-01-01

    This is a report of summarized results of investigation and analysis on fracture of thermometer which is direct reason of sodium leakage incident at the second main cooling system of fast breeder reactor `Monju`. Various surveys such as on various damage factors, on flowing power vibrational features containing flowing power vibrational test of thermometer, on evaluation of high cycle fatigue due to flowing power vibration and details on propagation of and fracture due to fatigue crack, on why only said thermometer damaged, and so forth were executed. As results of these examinations, a decision was arrived that high cycle fatigue due to vibration formed by fluid force (fluid force vibration) was a direct cause of the thermometer damage. (G.K.)

  1. Cryogenic thermometer calibration system using a helium cooling loop and a temperature controller [for LHC magnets

    CERN Document Server

    Chanzy, E; Thermeau, J P; Bühler, S; Joly, C; Casas-Cubillos, J; Balle, C

    1998-01-01

    The IPN-Orsay and CERN are designing in close collaboration a fully automated cryogenic thermometer calibration facility which will calibrate in 3 years 10,000 cryogenic thermometers required for the Large Hadron Collider (LHC) operation. A reduced-scale model of the calibration facility has been developed, which enables the calibration of ten thermometers by comparison with two rhodium-iron standard thermometers in the 1.8 K to 300 K temperature range under vacuum conditions. The particular design, based on a helium cooling loop and an electrical temperature controller, gives good dynamic performances. This paper describes the experimental set-up and the data acquisition system. Results of experimental runs are also presented along with the estimated global accuracy for the calibration. (3 refs).

  2. Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert

    Science.gov (United States)

    Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.

    2001-01-01

    Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers can be corrupted by emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.

  3. Development and psychometric testing of a new tool for detecting moral distress: the Moral Distress Thermometer.

    Science.gov (United States)

    Wocial, Lucia D; Weaver, Michael T

    2013-01-01

    To report the development and psychometric testing of the Moral Distress Thermometer. The Moral Distress Thermometer is a new screening tool to measure moral distress in nurses who practise in the hospital setting. Moral distress occurs when one knows the ethically correct thing to do, but is prevented from acting on that perceived obligation. It is a well documented phenomenon with negative consequences that may be experienced by nurses. Creating an instrument to effectively and efficiently measure moral distress in a timely way has been identified as a priority for nursing. This study used a cross-sectional survey design. Data collection for this research occurred in 2009. Participants simultaneously completed either the adult or pediatric version of the Moral Distress Scale version 2009 and the Moral Distress Thermometer. A total of 529 participants from various clinical areas completed both tools. Coefficients alpha were adequate for both Adult (0·90) and Pediatric (0·92) Moral Distress Scale 2009 scales. Statistically significant Pearson correlations were found for the Moral Distress Thermometer with Adult Moral Distress Scale 2009 and Pediatric Moral Distress Scale 2009 and higher Moral Distress Thermometer, Adult Moral Distress Scale 2009 and Pediatric Moral Distress Scale 2009 means for participants who had left or who considered leaving a position because of moral distress. These findings provide support for the validity of the Moral Distress Thermometer. © 2012 Blackwell Publishing Ltd.

  4. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  5. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  6. Magnetic Criticality Enhanced Hybrid Nanodiamond Thermometer under Ambient Conditions

    Science.gov (United States)

    Wang, Ning; Liu, Gang-Qin; Leong, Weng-Hang; Zeng, Hualing; Feng, Xi; Li, Si-Hong; Dolde, Florian; Fedder, Helmut; Wrachtrup, Jörg; Cui, Xiao-Dong; Yang, Sen; Li, Quan; Liu, Ren-Bao

    2018-01-01

    Nitrogen-vacancy (NV) centers in diamond are attractive as quantum sensors owing to their superb coherence under ambient conditions. However, the NV center spin resonances are relatively insensitive to some important parameters such as temperature and pressure. Here we design and experimentally demonstrate a hybrid nanothermometer composed of NV centers and a magnetic nanoparticle (MNP), in which the temperature sensitivity is enhanced by the critical magnetization of the MNP near the ferromagnetic-paramagnetic transition temperature. The temperature susceptibility of the NV center spin resonance reaches 14 MHz /K , nearly 200 times larger than that of bare NV centers. The sensitivity of a hybrid nanothermometer composed of a Cu1 -xNix MNP and a nanodiamond is measured to be 11 mK /√{Hz } under ambient conditions. The working range of the hybrid thermometer can be designed from cryogenic temperature to about 600 K by tuning the chemical composition of the Cu1 -xNix MNP. We demonstrate in situ detection of the magnetic phase transition of a single magnetic nanoparticle using the hybrid nanothermometer. This hybrid nanothermometer provides a novel approach to studying a broad range of thermal processes at nanoscales such as nanoplasmonics, heat-stimulated subcellular processes, and thermodynamics of nanosystems.

  7. Magnetic Criticality Enhanced Hybrid Nanodiamond Thermometer under Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Ning Wang

    2018-03-01

    Full Text Available Nitrogen-vacancy (NV centers in diamond are attractive as quantum sensors owing to their superb coherence under ambient conditions. However, the NV center spin resonances are relatively insensitive to some important parameters such as temperature and pressure. Here we design and experimentally demonstrate a hybrid nanothermometer composed of NV centers and a magnetic nanoparticle (MNP, in which the temperature sensitivity is enhanced by the critical magnetization of the MNP near the ferromagnetic-paramagnetic transition temperature. The temperature susceptibility of the NV center spin resonance reaches 14  MHz/K, nearly 200 times larger than that of bare NV centers. The sensitivity of a hybrid nanothermometer composed of a Cu_{1-x}Ni_{x} MNP and a nanodiamond is measured to be 11  mK/sqrt[Hz] under ambient conditions. The working range of the hybrid thermometer can be designed from cryogenic temperature to about 600 K by tuning the chemical composition of the Cu_{1-x}Ni_{x} MNP. We demonstrate in situ detection of the magnetic phase transition of a single magnetic nanoparticle using the hybrid nanothermometer. This hybrid nanothermometer provides a novel approach to studying a broad range of thermal processes at nanoscales such as nanoplasmonics, heat-stimulated subcellular processes, and thermodynamics of nanosystems.

  8. Some results from a temperature evaluation of a cotton field with infrared thermometer for agricultural use

    International Nuclear Information System (INIS)

    Ovcharova, A.; Kolev, N.; Nedkov, N.

    2005-01-01

    The aims of the present study were connected with evaluation of the basic soil properties, distribution of thermal, hydrological and electronic soil properties and criteria for minimization of the measurement points, obtained in the cotton non-irrigated field of the Institute of durum wheat and cotton near Chirpan. It were measured crop temperature of cotton field and soil surface temperature distribution during the main vegetative stages. Using the energy balance equation and soil water balance equation was calculated the intensity of evapotranspiration during the days of measurements

  9. Unquenched Complex Dirac Spectra at Nonzero Chemical Potential: Two-Color QCD Lattice Data versus Matrix Model

    International Nuclear Information System (INIS)

    Akemann, Gernot; Bittner, Elmar

    2006-01-01

    We compare analytic predictions of non-Hermitian chiral random matrix theory with the complex Dirac operator eigenvalue spectrum of two-color lattice gauge theory with dynamical fermions at nonzero chemical potential. The Dirac eigenvalues come in complex conjugate pairs, making the action of this theory real and positive for our choice of two staggered flavors. This enables us to use standard Monte Carlo simulations in testing the influence of the chemical potential and quark mass on complex eigenvalues close to the origin. We find excellent agreement between the analytic predictions and our data for two different volumes over a range of chemical potentials below the chiral phase transition. In particular, we detect the effect of unquenching when going to very small quark masses

  10. Detecting the propagation effect of terahertz wave inside the two-color femtosecond laser filament in the air

    Science.gov (United States)

    Zhao, J.; Zhang, X.; Li, S.; Liu, C.; Chen, Y.; Peng, Y.; Zhu, Y.

    2018-03-01

    In this work, to decide the existence of terahertz (THz) wave propagation effect, THz pulses emitted from a blocked two-color femtosecond laser filament with variable length were recorded by a standard electric-optic sampling setup. The phenomenon of temporal advance of the THz waveform's peak with the increasing filament length has been observed. Together with another method of knife-edge measurement which aims at directly retrieving the THz beam diameter, both the experimental approaches have efficiently indicated the same filament range within which THz wave propagated inside the plasma column. At last, a preliminary two-dimensional near-field scanning imaging of the THz spot inside the cross section of the filament has been suggested as the third way to determine the issue of THz wave propagation effect.

  11. A Challenge to Improve High-Temperature Platinum Resistance Thermometer

    Science.gov (United States)

    Tanaka, Y.; Widiatmo, J. V.; Harada, K.; Kobayashi, T.; Yamazawa, K.

    2017-05-01

    High-temperature standard platinum resistance thermometers (HTSPRTs) are used to interpolate the international temperature scale of 1990 (ITS-90), especially for temperatures between the aluminum and the silver points. For this, long-term stability of the HTSPRT is essential. CHINO R800-3L type SPRT, which has a nominal resistance at the triple point of water (TPW) around 0.25 Ω , is the one developed earlier for the interpolation of the ITS-90 at this temperature range. Further development to this previous model has been carried out for the purpose of improving the thermal stability. The improvement was focused on reducing the effect coming from the difference in thermal expansion between platinum wire and the quartz frame on which the platinum wire is installed. New HTSPRTs were made by CHINO Corporation. Some series of tests were carried out at CHINO and at NMIJ. Initial tests after the HTSPRT fabrication were done at CHINO, where thermal cycles between 500°C and 980°C were applied to the HTSPRTs to see change in the resistances at the TPW (R_{TPW}) and at the gallium point (R_{Ga}). Repeated resistance measurements at the silver point (R_{Ag}) were performed after completing the thermal cycling test. Before and after every measurement at silver point, R_{TPW} was measured, while before and after every two silver point realization R_{Ga} were measured. After completing this test, the HTSPRTs were transported to NMIJ, where the same repeated measurements at the silver point were done at NMIJ. These were then repeated at CHINO and at NMIJ upon repeated transportation among the institutes, to evaluate some effect due to transportation. This paper reports the details of the above-mentioned tests, the results and the analysis.

  12. Nonvolatile two-step, two-color holography with continuous-wave lights for both congruent and near-stoichiometric LiNbO3:Fe

    International Nuclear Information System (INIS)

    Shen Yan; Zhang Guoquan; Fu Bo; Xu Qingjun; Xu Jingjun

    2004-01-01

    We have studied theoretically the steady-state nonvolatile two-step, two-color holographic recording performance for both the congruent and the near-stoichiometric LiNbO 3 :Fe based on the two-center model (the deep-trap and the shallow-trap centers are Fe 2+ /Fe 3+ and Nb Li 4+ /Nb Li 5+ , respectively). The results show that the direct electron exchange between the Fe 2+ /Fe 3+ centers and the Nb Li 4+ /Nb Li 5+ centers due to the tunneling effect dominates the charge-transfer process during the nonvolatile two-step, two-color holography and determines the two-step, two-color holography performance in LiNbO 3 :Fe. We have further studied the effects of the crystal stoichiometry on the performance of the two-step, two-color holography. It is shown that, as far as the total space-charge field is considered, the nonvolatile two-step, two-color holography performance in the near-stoichiometric LiNbO 3 :Fe is much better than that in the congruent LiNbO 3 :Fe within the intensity range reachable by the continuous-wave lights

  13. Stability of High Temperature Standard Platinum Resistance Thermometers at High Temperatures

    Directory of Open Access Journals (Sweden)

    Y. A. ABDELAZIZ

    2010-05-01

    Full Text Available An investigation of the stability of high temperature standard platinum resistance thermometers HTSPRTs has been carried out for two different designs thermometers (with nominal resistance 0.25 Ω and 2.5 Ω from two different suppliers. The thermometers were heated for more than 160 hours at temperatures above 960 0C using a vertical furnace with a ceramic block. A study was made of the influence of the heat treatment on the stability of the resistance at the triple point of water, and on the relative resistance W(Ga at the melting point of gallium. The thermometers showed a correlation between the drift note and the values of W(Ga. It was found also that the HTSPRT which has a sensor with strip shaped support and low nominal resistance is more stable than the HTSPRT which has a sensor in the form of a coil wound on silica cross. The 0.25 Ω thermometer has better stability @ 7x10-6 0C (at TPW after 40 hour. Factors affecting the stability and accuracy of HTSPRT also will be discussed.

  14. Polar red-emitting rhodamine dyes with reactive groups: synthesis, photophysical properties, and two-color STED nanoscopy applications.

    Science.gov (United States)

    Kolmakov, Kirill; Wurm, Christian A; Meineke, Dirk N H; Göttfert, Fabian; Boyarskiy, Vadim P; Belov, Vladimir N; Hell, Stefan W

    2014-01-03

    The synthesis, reactivity, and photophysical properties of new rhodamines with intense red fluorescence, two polar residues (hydroxyls, primary phosphates, or sulfonic acid groups), and improved hydrolytic stability of the amino-reactive sites (NHS esters or mixed N-succinimidyl carbonates) are reported. All fluorophores contain an N-alkyl-1,2-dihydro-2,2,4-trimethylquinoline fragment, and most of them bear a fully substituted tetrafluoro phenyl ring with a secondary carboxamide group. The absorption and emission maxima in water are in the range of 635-639 and 655-659 nm, respectively. A vastly simplified approach to red-emitting rhodamines with two phosphate groups that are compatible with diverse functional linkers was developed. As an example, a phosphorylated dye with an azide residue was prepared and was used in a click reaction with a strained alkyne bearing an N-hydroxysuccinimid (NHS) ester group. This method bypasses the undesired activation of phosphate groups, and gives an amphiphilic amino-reactive dye, the solubility and distribution of which between aqueous and organic phases can be controlled by varying the pH. The presence of two hydroxyl groups and a phenyl ring with two carboxyl residues in the dyes with another substitution pattern is sufficient for providing the hydrophilic properties. Selective formation of a mono-N-hydroxysuccinimidyl ester from 5-carboxy isomer of this rhodamine is reported. The fluorescence quantum yields varied from 58 to 92% for free fluorophores, and amounted to 18-64% for antibody conjugates in aqueous buffers. The brightness and photostability of these fluorophores facilitated two-color stimulated emission depletion (STED) fluorescence nanoscopy of biological samples with high contrast and minimal background. Selecting a pair of fluorophores with absorption/emission bands at 579/609 and 635/655 nm enabled two-color channels with low cross-talk and negligible background at approximately 40 nm resolution. Copyright

  15. Momentum spectra of electrons rescattered from rare-gas targets following their extraction by one- and two-color femtosecond laser pulses

    International Nuclear Information System (INIS)

    Ray, D.; Chen Zhangjin; De, S.; Cao, W.; Le, A. T.; Lin, C. D.; Cocke, C. L.; Litvinyuk, I. V.; Kling, M. F.

    2011-01-01

    We have used velocity-map imaging to measure the three-dimensional momenta of electrons rescattered from Xe and Ar following the liberation of the electrons from these atoms by 45 fs, 800 nm intense laser pulses. Strong structure in the rescattering region is observed in both angle and energy, and is interpreted in terms of quantitative rescattering (QRS) theory. Momentum images have also been taken with two-color (800 nm + 400 nm) pulses on Xe targets. A strong dependence of the spectra on the relative phase of the two colors is observed in the rescattering region. Interpretation of the phase dependence using both QRS theory and a full solution to the time-dependent Schroedinger equation shows that the rescattered electrons provide a much more robust method for determining the relative phase of the two colors than do the direct electrons.

  16. Two-color cytofluorometry and cellular properties of the urokinase receptor associated with a human metastatic carcinomatous cell line

    International Nuclear Information System (INIS)

    Takahashi, K.; Gojobori, T.; Tanifuji, M.

    1991-01-01

    Purified human urokinase was labeled with either fluorescein isothiocyanate or iodine-125 and used as a probe for binding to the human metastatic carcinomatous cell line, Detroit 562. Cytofluorometry showed that the ligand bound preferentially to cells that had been exposed to acidic pH. The binding was competitive and decreased after mild tryptic digestion. The bound ligand could be removed by restoration of the cells to a low pH. Therefore, the cells had specific binding sites. The bound urokinase was involved in the breakdown of fibrin. Two-color cytofluorometric maps were constructed by counterstaining with propidium iodide. Results suggested that there were different cell populations that had different numbers of receptors and amounts of DNA. We cloned cells and found that single clones had homogeneous levels of receptors with different dissociation constants (from 10(-13) to 10(-11) mol/mg protein) for different clones. Cells of one clone, C5, which had high levels of receptor production, moved characteristically on a glass substratum coated with gold particles and reacted with wheat germ agglutinin, but not with concanavalin A. The receptors were found together with adhesion proteins at the sites where the cells adhered to the substrate. These results and the data obtained by zymography of the cellular proteins suggested that the urokinase-type plasminogen activators were bound to the receptors. The membrane-associated activator may stimulate local proteolysis, facilitating the migration of the tumor cell across the substrate

  17. Two-color cytofluorometry and cellular properties of the urokinase receptor associated with a human metastatic carcinomatous cell line

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, K.; Gojobori, T.; Tanifuji, M. (Shimane Medical Univ., Izumo (Japan))

    1991-02-01

    Purified human urokinase was labeled with either fluorescein isothiocyanate or iodine-125 and used as a probe for binding to the human metastatic carcinomatous cell line, Detroit 562. Cytofluorometry showed that the ligand bound preferentially to cells that had been exposed to acidic pH. The binding was competitive and decreased after mild tryptic digestion. The bound ligand could be removed by restoration of the cells to a low pH. Therefore, the cells had specific binding sites. The bound urokinase was involved in the breakdown of fibrin. Two-color cytofluorometric maps were constructed by counterstaining with propidium iodide. Results suggested that there were different cell populations that had different numbers of receptors and amounts of DNA. We cloned cells and found that single clones had homogeneous levels of receptors with different dissociation constants (from 10(-13) to 10(-11) mol/mg protein) for different clones. Cells of one clone, C5, which had high levels of receptor production, moved characteristically on a glass substratum coated with gold particles and reacted with wheat germ agglutinin, but not with concanavalin A. The receptors were found together with adhesion proteins at the sites where the cells adhered to the substrate. These results and the data obtained by zymography of the cellular proteins suggested that the urokinase-type plasminogen activators were bound to the receptors. The membrane-associated activator may stimulate local proteolysis, facilitating the migration of the tumor cell across the substrate.

  18. Trade-offs in disease and bleaching susceptibility among two color morphs of the Hawaiian reef coral, Montipora capitata

    Science.gov (United States)

    Shore-Maggio, Amanda; Callahan, Sean M.; Aeby, Greta S.

    2018-06-01

    Two threats impacting coral reefs are bleaching and disease, and differential susceptibility to both exists among and within coral taxa. Bleaching resistance is commonly linked to the clade of endosymbiotic Symbiodinium, but may come at a cost to other biological traits. Montipora capitata is an Indo-Pacific reef-building coral with two color morphs, red and orange, which harbor different clades of Symbiodinium. We explored whether these color morphs displayed differences in bleaching/disease susceptibility and other biological traits (growth rate, reproductive output, and lipid content). We found a trade-off between disease and bleaching susceptibility. The orange morph had significantly higher disease prevalence, whereas the red morph had significantly higher bleaching prevalence. Thermal stress experiments found that bleaching and loss of photochemical efficiency occurred significantly faster in the red morph, but at normal temperatures, the red morph had a significantly higher growth rate. Higher abundance of the red morph in the field suggests that disease resistance is a more successful strategy in the absence of thermal stress events. The orange morph may better tolerate increases in sea temperatures, but may not persist due to decreased growth rate and increased disease susceptibility. Trade-offs in response to stressors highlight the need to consider local and global threats to coral reefs.

  19. Probabilistic Cash Flow-Based Optimal Investment Timing Using Two-Color Rainbow Options Valuation for Economic Sustainability Appraisement

    Directory of Open Access Journals (Sweden)

    Yonggu Kim

    2017-10-01

    Full Text Available This research determines the optimal investment timing using real options valuation to support decision-making for economic sustainability assessment. This paper illustrates an option pricing model using the Black-Scholes model applied to a case project to understand the model performance. Applicability of the project to the model requires two Monte Carlo simulations to satisfy a Markov process and a Wiener process. The position of project developers is not only the seller of products, but it is also the buyer of raw materials. Real options valuation can be influenced by the volatility of cash outflow, as well as the volatility of cash inflow. This study suggests two-color rainbow options valuation to overcome this issue, which is demonstrated for a steel plant project. The asymmetric results of the case study show that cash outflow (put option influences the value of the steel plant project more than cash inflow (call option does of which the discussion of the results is referred to a sensitivity analysis. The real options valuation method proposed in this study contributes to the literature on applying the new model, taking into consideration that investors maximize project profitability for economic sustainable development.

  20. MEMS Tunneling Micro Thermometer Based onTip Deflection of Bimetallic Cantilever Beam

    Directory of Open Access Journals (Sweden)

    Samrand K. Nezhadian

    2007-10-01

    Full Text Available Micro-electro-mechanical (MEM technology promises to significantly reduce the size, weight and cost of a variety of sensor systems. In this article has been described a highly sensitive novel type of thermometer based on deflection of a “bimetallic” microbeam. The proposed thermometer converts the thermal changes of a cantilevered bimetallic beam of submillimeter size into an electrical signal through tunneling-current modulation. The governing thermo-mechanical equation of a bimetallic cantilever beam has been derived and solved analytically. The obtained results show that the proposed tunneling micro thermometer is very sensitive to temperature changes due to exponential increasing of tunneling current but because of small gap between metallic electrodes, measurable range of temperature changes is small.

  1. Construction and test of a superconducting phase-transition thermometer for bolometric cryodetectors

    International Nuclear Information System (INIS)

    Meier, H.J.

    1990-10-01

    In the framework of a project for the study of bolometric cryodetectors for the detection of heavy ions a superconducting phase-transition thermometer for the detection of heavy ions was constructed and tested with α particles. The thermometer consists of a 10 nm thick aluminium film, which was evaporated on a sapphire absorber with a typical magnitude of 2.5x2.5 x 0.33 mm 3 . By the method of photolithography the aluminium film was structured in form of a meander. By this at the working point of the thermometer resistances of up to 60 kΩ resulted, so that the signal acquisition was possible with usual readout electronics. Several of these thermometers were constructed, characterized in their properties, and tested. For the study of the detector properties of the thermometers in characterization measurements the width of the phase transitions dT ≅ 2 mK, the temperature dependence of the resistance to dR/dT ≅ 10MΩ/K, the thermal conductivity of the thermal coupling to the cooling bath, and the heat capacity of the bolometers to C ≅ 2 nJ/K were determined.The best energy resolution, which was reached with one of the superconducting phase-transition thermometers, amounts to 50 keV for 5.5 MeV α particles, which corresponds to a relative resolution of 0,9%. By this in the order of magnitude the quality of semiconductor detectors was reached. The best temperature resolution amounts to about 1 μK. (orig./HSI) [de

  2. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    Energy Technology Data Exchange (ETDEWEB)

    Greenen, Adam; Pearce, Jonathan [National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, (United Kingdom); Cruickshank, David; Bramley, Paul [Metrosol Limited, Plum Park Estate, Watling Street, Paulerspury, Northamptonshire, NN12 6LQ, (United Kingdom)

    2015-07-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  3. Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

    International Nuclear Information System (INIS)

    Greenen, Adam; Pearce, Jonathan; Cruickshank, David; Bramley, Paul

    2015-01-01

    The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

  4. Accuracy of peripheral thermometers for estimating temperature: a systematic review and meta-analysis.

    Science.gov (United States)

    Niven, Daniel J; Gaudet, Jonathan E; Laupland, Kevin B; Mrklas, Kelly J; Roberts, Derek J; Stelfox, Henry Thomas

    2015-11-17

    Body temperature is commonly used to screen patients for infectious diseases, establish diagnoses, monitor therapy, and guide management decisions. To determine the accuracy of peripheral thermometers for estimating core body temperature in adults and children. MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL Plus from inception to July 2015. Prospective studies comparing the accuracy of peripheral (tympanic membrane, temporal artery, axillary, or oral) thermometers with central (pulmonary artery catheter, urinary bladder, esophageal, or rectal) thermometers. 2 reviewers extracted data on study characteristics, methods, and outcomes and assessed the quality of individual studies. 75 studies (8682 patients) were included. Most studies were at high or unclear risk of patient selection bias (74%) or index test bias (67%). Compared with central thermometers, peripheral thermometers had pooled 95% limits of agreement (random-effects meta-analysis) outside the predefined clinically acceptable range (± 0.5 °C), especially among patients with fever (-1.44 °C to 1.46 °C for adults; -1.49 °C to 0.43 °C for children) and hypothermia (-2.07 °C to 1.90 °C for adults; no data for children). For detection of fever (bivariate random-effects meta-analysis), sensitivity was low (64% [95% CI, 55% to 72%]; I2 = 95.7%; P temperature measurement techniques are limited. Pooled data are associated with interstudy heterogeneity that is not fully explained by stratified and metaregression analyses. Peripheral thermometers do not have clinically acceptable accuracy and should not be used when accurate measurement of body temperature will influence clinical decisions. None.

  5. Low-energy X-ray detection in cryogenic detectors with tungsten thermometers

    International Nuclear Information System (INIS)

    Colling, P.; Nucciotti, A.; Bucci, C.; Cooper, S.; Ferger, P.; Frank, M.; Nagel, U.; Proebst, F.; Seidel, W.

    1994-08-01

    In the course of our development of calorimetric particle detectors with superconducting phase transition thermometers, we have succeeded in depositing epitaxial α-tungsten films on sapphire which have critical temperatures T c near 15 mK. To our knowledge this is the first time that the T c of bulk tungsten has been observed in thin films. Such films used as thermometers are very sensitive and provide good energy resolution: with 4 g and 32 g sapphire crystals energy resolutions of better than 100eV (FWHM) for 1.5 KeV X-rays have been achieved. (orig.)

  6. The free electron gas primary thermometer using an ordinary bipolar junction transistor approaches ppm accuracy

    Science.gov (United States)

    Mimila-Arroyo, J.

    2017-06-01

    In this paper, it is demonstrated that the free electron gas primary thermometer based on a bipolar junction transistor is able to provide the temperature with an accuracy of a few parts per million. Its simple functioning principle exploits the behavior of the collector current when properly biased to extract the temperature. Using general purpose silicon transistors at the water triple point (273.16 K) and gallium melting point (302.9146), an accuracy of a few parts per million has been reached, constituting the simplest and the easiest to operate primary thermometer, that might be considered even for the redefinition of Kelvin.

  7. Study on the KM capacitor base thermometers in the 42-273 K range

    International Nuclear Information System (INIS)

    Luzganov, V.S.; Mats'ko, A.A.

    1988-01-01

    Thermometric characteristics of the KM-5a-HZ0 monolithic capacitors in the 42-273 K temperature range are studied. Capacitors capacitance - temperature relation is considered in details. The data reproducibility after 5, 23, 34, 50, 51 and 57 days is studied, the accuracy of temperature measurements by the given thermometers is determined. Recommendations on selection of cpacitors, suitable for application as thermometer, are given. These capacitors permit temperature measurement in the 42-225 K range with the error of ± 0.5 K, and above 225 K the error is ± 1K. 8 refs.; 1 fig.; 1 tab

  8. Mobile In Vivo Infrared Data Collection and Diagnoses Comparison System

    Science.gov (United States)

    Mintz, Frederick W. (Inventor); Moynihan, Philip I. (Inventor); Gunapala, Sarath D. (Inventor)

    2013-01-01

    Described is a mobile in vivo infrared brain scan and analysis system. The system includes a data collection subsystem and a data analysis subsystem. The data collection subsystem is a helmet with a plurality of infrared (IR) thermometer probes. Each of the IR thermometer probes includes an IR photodetector capable of detecting IR radiation generated by evoked potentials within a user's skull. The helmet is formed to collect brain data that is reflective of firing neurons in a mobile subject and transmit the brain data to the data analysis subsystem. The data analysis subsystem is configured to generate and display a three-dimensional image that depicts a location of the firing neurons. The data analysis subsystem is also configured to compare the brain data against a library of brain data to detect an anomaly in the brain data, and notify a user of any detected anomaly in the brain data.

  9. In-situ calibration of nuclear-plant platinum resistance thermometers using Johnson noise methods. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Shepard, R.L.

    1983-06-01

    Methods for in situ calibration of reactor plant platinum resistance thermometers using Johnson noise measurements were tested in the laboratory and in two operating reactors: Diablo Canyon and Sequoyah. The Johnson noise methods provide an absolute measurement of the thermometer temperature and can be compared with the dc calibration of the thermometers to confirm their calibration without removing the thermometers from the plant coolant loops. Inaccuracies of less than 0.1% were obtained with these methods for ideal situations where the noise measuring equipment could be connected directly to the installed thermometer terminals. For measurements made at the ends of long extension cables, inaccuracies were 0.5 to 1.0%, at best. Extension cables must be optimized and well characterized electrically to achieve such accuracies. Other factors that affect the accuracy of these methods were evaluated

  10. Simultaneous two-phase flow measurement of spray mixing process by means of high-speed two-color PIV

    International Nuclear Information System (INIS)

    Zhang, Ming; Xu, Min; Hung, David L S

    2014-01-01

    In this article, a novel high-speed two-color PIV optical diagnostic technique has been developed and applied to simultaneously measure the velocity flow-fields of a multi-hole spark-ignition direct injection (SIDI) fuel injector spray and its ambient gas in a high-pressure constant volume chamber. To allow for the phase discrimination between the fuel droplets and ambient gas, a special tracer-filter system was designed. Fluorescent seeding particles with Sauter mean diameter (SMD) of 4.8 µm were used to trace the gas inside the chamber. With a single high-speed Nd:YLF laser sheet (527 nm) as the incident light source, the Mie-scattering signal marked the phase of the fuel spray, while the fluorescent signal generated from the seeding particles tracked the phase of ambient gas. A high-speed camera, with an image-doubler (mounted in front of the camera lens) that divided the camera pixels into two parts focusing on the same field of view, was used to collect the Mie-scattering signal and LIF (laser induced fluorescence) signal simultaneously with two carefully selected optical filters. To accommodate the large dynamic range of velocities in the two phases (1–2 orders of magnitude difference), two separation times (dt) were introduced. This technique was successfully applied to the liquid spray and ambient gas two-phase flow measurement. The measurement accuracy was compared with those from LDV (laser Doppler velocimetry) measurement and good agreement was obtained. Ambient gas motion surrounding the fuel spray was investigated and characterized into three zones. The momentum transfer process between the fuel spray and ambient gas in each zone was analyzed. The two-phase flow interaction under various superheated conditions was investigated. A strengthened momentum transfer from the liquid spray to the ambient was observed with increased superheat degree. (paper)

  11. Dissection of Rovibronic Structure by Polarization-Resolved Two-Color Resonant Four-Wave Mixing Spectroscopy

    Science.gov (United States)

    Murdock, Daniel; Burns, Lori A.; Vaccaro, Patrick H.

    2009-08-01

    A synergistic theoretical and experimental investigation of stimulated emission pumping (SEP) as implemented in the coherent framework of two-color resonant four-wave mixing (TC-RFWM) spectroscopy is presented, with special emphasis directed toward the identification of polarization geometries that can distinguish spectral features according to their attendant changes in rotational quantum numbers. A vector-recoupling formalism built upon a perturbative treatment of matter-field interactions and a state-multipole expansion of the density operator allowed the weak-field signal intensity to be cast in terms of a TC-RFWM response tensor, RQ(K)(ɛ4*ɛ3ɛ2*ɛ1;Jg,Je,Jh,Jf), which separates the transverse characteristics of the incident and generated electromagnetic waves (ɛ4*ɛ3ɛ2*ɛ1) from the angular momentum properties of the PUMP and DUMP resonances (Jg,Je,Jh,Jf). For an isolated SEP process induced in an isotropic medium, the criteria needed to discriminate against subsets of rovibronic structure were encoded in the roots of a single tensor element, R0(0)(ɛ4*ɛ3ɛ2*ɛ1;Jg,Je,Jh,Je). By assuming all optical fields to be polarized linearly and invoking the limit of high quantum numbers, specific angles of polarization for the detected signal field were found to suppress DUMP resonances selectively according to the nature of their rotational branch and the rotational branch of the meshing PUMP line. These predictions were corroborated by performing SEP measurements on the ground electronic potential energy surface of tropolone in two distinct regimes of vibrational excitation, with the near-ultraviolet Ã1B2-X˜1A1 (π* ← π) absorption system affording the requisite PUMP and DUMP transitions.

  12. Application of radio frequency based digital thermometer for real-time monitoring of dairy cattle rectal temperature

    Directory of Open Access Journals (Sweden)

    Tridib Debnath

    2017-09-01

    Full Text Available Aim: Dairy cattle health monitoring program becomes vital for detecting the febrile conditions to prevent the outbreak of the animal diseases as well as ensuring the fitness of the animals that are directly affecting the health of the consumers. The aim of this study was to validate real-time rectal temperature (RT data of radio frequency based digital (RFD thermometer with RT data of mercury bulb (MB thermometer in dairy cattle. Materials and Methods: Two experiments were conducted. In experiment I, six female Jersey crossbred cattle with a mean (±standard error of the mean body weight of 534.83±13.90 kg at the age of 12±0.52 years were used to record RT for 2 h on empty stomach and 2 h after feeding at 0, 30, 60, 90, and 120 min using a RFD thermometer as well as a MB thermometer. In experiment II, six female Jersey crossbred cattle were further used to record RT for 2 h before exercise and 2 h after exercise at 0, 30, 60, 90, and 120 min. Two-way repeated measures analysis of variance with post hoc comparisons by Bonferroni test was done. Results: Real-time RT data recorded by RFD thermometer as well as MB thermometer did not differ (p>0.05 before and after feeding/exercise. An increase (p<0.05 in RT after feeding/exercise in experimental crossbred cattle was recorded by both RFD thermometer and MB thermometer. Conclusion: The results obtained in the present study suggest that the body temperature recordings from RFD thermometer would be acceptable and thus RFD thermometer could work well for monitoring real-time RT in cattle.

  13. Comparison of soot formation for diesel and jet-a in a constant volume combustion chamber using two-color pyrometry

    KAUST Repository

    Jing, Wei; Roberts, William L.; Fang, Tiegang

    2014-01-01

    The measurement of the two-color line of sight soot and KL factor for NO.2 diesel and jet-A fuels was conducted in an optical constant volume combustion chamber by using a high speed camera under 1000 K ambient temperature and varied oxygen

  14. Evaluation of a Teaching Kit for Family and Consumer Science Classrooms: Motivating Students to Use a Food Thermometer with Small Cuts of Meat

    Science.gov (United States)

    Edwards, Zena; Edlefsen, Miriam; Hillers, Virginia; McCurdy, Sandra M.

    2005-01-01

    The U.S. Dept. of Agriculture recommends use of food thermometers to safely cook small cuts of meat, yet most consumers do not use them. Consumers lack knowledge about how and why to use food thermometers with small cuts of meat. Opportunities exist for family and consumer science classes to provide education about thermometers to adolescents, who…

  15. Ultrasensitive thermometer for atmospheric pressure operation based on a micromechanical resonator

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Pini, V.; Tamayo, J.

    2014-01-01

    For highly integrated systems for bio and chemical analysis a precise and integrated measurement of temperature is of fundamental importance. We have developed an ultrasensitive thermometer based on a micromechanical resonator for operation in air. The high quality factor and the strong temperatu...

  16. Method for determining the outlet temperature of fuel assemblies unsupplied with thermometer in WWER-440 reactors

    International Nuclear Information System (INIS)

    Miko, S.; Kalya, Z.; Hamvas, I.

    1987-09-01

    The paper outlines a method for the evaluation of the outlet temperatures of fuel assemblies unsupplied with thermometer in WWER-440 reactors. The process is based on interpolation of directly measured assembly temperatures. A quantitative comparison of the errors of described algorithm to those of standard plant-computer interpolation rutine is also presented. (author)

  17. Time-Lapse and Slow-Motion Tracking of Temperature Changes: Response Time of a Thermometer

    Science.gov (United States)

    Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.

    2017-01-01

    We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure…

  18. Dissociation Pathways of Benzylpyridinium "Thermometer" Ions Depend on the Activation Regime: An IRMPD Spectroscopy Study

    NARCIS (Netherlands)

    Morsa, D.; Gabelica, V.; Rosu, F.; Oomens, J.; De Pauw, E.

    2014-01-01

    The dissociation of benzylpyridinium "thermometer" ions is widely used to calibrate the internal energy of ions produced in mass spectrometry. The fragmentation mechanism is usually believed to yield a benzylium cation, although recent studies suggest the possibility of a rearrangement leading to

  19. Correction of the dynamic response of the ''Gamma thermometers'' using a digital filter

    International Nuclear Information System (INIS)

    Jacquot, J.P.; Lobert, J.P.

    1985-01-01

    The ''gamma thermometer'' is a sensor used to measure on line the local power inside a PWR nuclear reactor. During transients, this sensor based on thermal exchanges, obes not give a fast response. This paper describes a microprocessor device that allows using a digital filtering technique, a correction of the dynamic response [fr

  20. Measurement time and statistics for a noise thermometer with a synthetic-noise reference

    Science.gov (United States)

    White, D. R.; Benz, S. P.; Labenski, J. R.; Nam, S. W.; Qu, J. F.; Rogalla, H.; Tew, W. L.

    2008-08-01

    This paper describes methods for reducing the statistical uncertainty in measurements made by noise thermometers using digital cross-correlators and, in particular, for thermometers using pseudo-random noise for the reference signal. First, a discrete-frequency expression for the correlation bandwidth for conventional noise thermometers is derived. It is shown how an alternative frequency-domain computation can be used to eliminate the spectral response of the correlator and increase the correlation bandwidth. The corresponding expressions for the uncertainty in the measurement of pseudo-random noise in the presence of uncorrelated thermal noise are then derived. The measurement uncertainty in this case is less than that for true thermal-noise measurements. For pseudo-random sources generating a frequency comb, an additional small reduction in uncertainty is possible, but at the cost of increasing the thermometer's sensitivity to non-linearity errors. A procedure is described for allocating integration times to further reduce the total uncertainty in temperature measurements. Finally, an important systematic error arising from the calculation of ratios of statistical variables is described.

  1. A High-Resolution Thermometer for the Range 0.75-1.0 K

    Science.gov (United States)

    Panek, J.; Nash, A.; Larson, M.; Mulders, N.

    1999-01-01

    We report on a new high-resolution thermometer (HRT) for use near the tricritical point in 3He-4He mixtures. It is based on an existing HRT design that uses a DC-SQUID to detect the magnetization of a paramagnetic sensing element.

  2. A Phase-Locked Loop Continuous Wave Sonic Anemometer-Thermometer

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Weller, F. W.; Busings, J. A.

    1979-01-01

    A continuous wake sonic anemometer-thermometer has been developed for simultaneous measurements of vertical velocity and temperature. The phase angle fluctuations are detected by means of a monolithic integrated phase-locked loop, the latter feature providing for inexpensive and accurate...

  3. Semi-transparent gold film as simultaneous surface heater and resistance thermometer for nucleate boiling studies

    International Nuclear Information System (INIS)

    Oker, E.; Merte, H. Jr.

    1981-01-01

    A large (22 x 25 mm) semi-transparent thin film of gold, approximately 400 A in thickness, is deposited on a glass substrate for simultaneous use as a heat source and resistance thermometer. Construction techniques and calibration procedures are described, and a sample application to a transient boiling process is included with simultaneous high speed photographs taken through the thin film from beneath

  4. Reliability of infrared thermometric measurements of skin temperature in the hand.

    Science.gov (United States)

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  5. Generation of an XUV supercontinuum by optimization of the angle between polarization planes of two linearly polarized pulses in a multicycle two-color laser field

    International Nuclear Information System (INIS)

    Yao Jinping; Zeng Bin; Fu Yuxi; Chu Wei; Ni Jielei; Li Yao; Xiong Hui; Xu Han; Cheng Ya; Xu Zhizhan; Liu Xiaojun; Chen, J.

    2010-01-01

    We theoretically investigate the high-order harmonic generation (HHG) in helium using a two-color laser field synthesized by an intense 25-fs laser pulse at 800 nm and a relatively weak ∼43-fs laser pulse at 1400 nm. When the polarization between the two pulses is arranged at an angle of ∼73 deg., supercontinuum spectra are dramatically broadened to 180 eV, which is sufficient to support an isolated ∼73-as pulse without any phase compensation. The physical mechanisms behind the phenomenon are well explained in terms of quantum and classical analyses. Furthermore, in the long-pulse regime, this method of extending the supercontinuum spectrum shows the significant advantage over previous two-color HHG schemes.

  6. 'Two-color' reflection multilayers for He-I and He-II resonance lines for micro-UPS using Schwarzschild objective

    International Nuclear Information System (INIS)

    Ejima, Takeo; Kondo, Yuzi; Watanabe, Makoto

    2000-01-01

    'Two-color' multilayers reflecting both He-I (58.4 nm) and He-II (30.4 nm) resonance lines have been designed and fabricated for reflection coatings of Schwarzschild objectives of micro-UPS instruments. They are designed so that their reflectances for both He-I and He-II resonance lines are more than 20%. The 'two-color' multilayers are piled double layers coated with top single layers. Fabricated are multilayers of SiC(top layer)-Mg/SiC(double layers) and SiC(top layer)-Mg/Y 2 O 3 (double layers), and their reflectances for the He-I and the He-II are 23% and 17%, and 20% and 23%, respectively

  7. How do we select multiple features? Transient costs for selecting two colors rather than one, persistent costs for color-location conjunctions.

    Science.gov (United States)

    Lo, Shih-Yu; Holcombe, Alex O

    2014-02-01

    In a previous study Lo, Howard, & Holcombe (Vision Research 63:20-33, 2012), selecting two colors did not induce a performance cost, relative to selecting one color. For example, requiring possible report of both a green and a red target did not yield a worse performance than when both targets were green. Yet a cost of selecting multiple colors was observed when selection needed be contingent on both color and location. When selecting a red target to the left and a green target to the right, superimposing a green distractor to the left and a red distractor to the right impeded performance. Possibly, participants cannot confine attention to a color at a particular location. As a result, distractors that share the target colors disrupt attentional selection of the targets. The attempt to select the targets must then be repeated, which increases the likelihood that the trial terminates when selection is not effective, even for long trials. Consistent with this, here we find a persistent cost of selecting two colors when the conjunction of color and location is needed, but the cost is confined to short exposure durations when the observer just has to monitor red and green stimuli without the need to use the location information. These results suggest that selecting two colors is time-consuming but effective, whereas selection of simultaneous conjunctions is never entirely successful.

  8. A Fluorescent Thermometer Based on a Pyrene-Labeled Thermoresponsive Polymer

    Directory of Open Access Journals (Sweden)

    Ulrich S. Schubert

    2010-08-01

    Full Text Available Thermoresponsive polymers that undergo a solubility transition by variation of the temperature are important materials for the development of ‘smart’ materials. In this contribution we exploit the solubility phase transition of poly(methoxy diethylene glycol methacrylate, which is accompanied by a transition from hydrophilic to hydrophobic, for the development of a fluorescent thermometer. To translate the polymer phase transition into a fluorescent response, the polymer was functionalized with pyrene resulting in a change of the emission based on the microenvironment. This approach led to a soluble polymeric fluorescent thermometer with a temperature range from 11 °C to 21 °C. The polymer phase transition that occurs during sensing is studied in detail by dynamic light scattering.

  9. In situ calibration of nuclear plant resistance thermometers using Johnson noise. Draft

    International Nuclear Information System (INIS)

    Blalock, T.V.; Roberts, M.J.; Shepard, R.L.

    1984-01-01

    Methods have been demonstrated in operating nuclear plants for the in situ calibration of resistance thermometers with agreement between measured noise temperatures and dc calibration temperatures well within these required by the plant. A comparison of the results of Johnson noise power testing results and uncertainties, the requirements for accuracy, and PRT calibration tolerances is shown. The methods use Johnson noise measurements and provide an absolute calibration independent of the prior dc calibration. The methods include techniques for characterization of the installed extension cables and the quantitative determination of induced EMI and its effect on the calibration. The techniques are applicable to ordinary 4-wire platinum resistance thermometers operating over their entire design temperature range and to extension cables of about 100 ft length. Careful attention needs to be paid to the choice or cables, location of terminal boxes, and grounding and shielding practices in the plant installation to achieve comparable results

  10. Reef coral δ18O thermometer in Hainan island waters, south China sea

    International Nuclear Information System (INIS)

    He Xuexian; Peng Zicheng; Wang Zhaorong; Huo Weiguo; Tan Jun; Nie Baofu; Chen Tegu; Zhong Jinliang

    2000-01-01

    An 18-year-long (1981-1998) study was conducted in Hainan Island waters (22 degree 22'N, 110 degree 39'E) to determine the relationship between δ 18 O in skeletal aragonite carbonate and sea surface temperature (SST) in porites lutea of reef-building corals. δ 18 O values in skeletal aragonite carbonate were measured by means of mass spectrometry. Coral samples grew at 5 m depth at Longwan Bay. Monthly measurements of the SST from 1960 to 1998 were taken at Qinglan Bay adjacent to the place of the collected samples. The thermometer shows that SST = -4.16 δ 18 O PDB + 4.9 (r = 0.80) and dδ 18 O/dT = -0.24 per mil/degree C. The δ 18 O thermometer is strongly influenced by the rainfall and runoff. Using the thermometer, the SST in the past hundred years with monthly resolution will be reconstructed and the climatic change in the northern area of South China Sea will be hind cast

  11. Genetically encoded ratiometric fluorescent thermometer with wide range and rapid response.

    Directory of Open Access Journals (Sweden)

    Masahiro Nakano

    Full Text Available Temperature is a fundamental physical parameter that plays an important role in biological reactions and events. Although thermometers developed previously have been used to investigate several important phenomena, such as heterogeneous temperature distribution in a single living cell and heat generation in mitochondria, the development of a thermometer with a sensitivity over a wide temperature range and rapid response is still desired to quantify temperature change in not only homeotherms but also poikilotherms from the cellular level to in vivo. To overcome the weaknesses of the conventional thermometers, such as a limitation of applicable species and a low temporal resolution, owing to the narrow temperature range of sensitivity and the thermometry method, respectively, we developed a genetically encoded ratiometric fluorescent temperature indicator, gTEMP, by using two fluorescent proteins with different temperature sensitivities. Our thermometric method enabled a fast tracking of the temperature change with a time resolution of 50 ms. We used this method to observe the spatiotemporal temperature change between the cytoplasm and nucleus in cells, and quantified thermogenesis from the mitochondria matrix in a single living cell after stimulation with carbonyl cyanide 4-(trifluoromethoxyphenylhydrazone, which was an uncoupler of oxidative phosphorylation. Moreover, exploiting the wide temperature range of sensitivity from 5°C to 50°C of gTEMP, we monitored the temperature in a living medaka embryo for 15 hours and showed the feasibility of in vivo thermometry in various living species.

  12. Infrared Model Spectra for Evolving Red Supergiants

    Directory of Open Access Journals (Sweden)

    Kyung-Won Suh

    1993-06-01

    Full Text Available The space and ground based infrared spectra of red supergiants are modeled and arranged in order of their evolutionary status with their theoretical model parameters. The chemical compositions of the dust shells around red supergiants are affected by the nuclear reaction and dredge-up processes of the cental stars. The processes are sensitively dependent on the initial mass, the initial chemical composition, and the evolutionary status. Miras, infrared carbon stars, and OH/IR stars have close link in their evolution in manu aspects, i,e., the chemical composition, the optical depths and the mass loss rates. The evolutionary tracks for the three classes of red supergiants on infrared two-color diagrams have been made from model calculations and IRAS observational data.

  13. Nonlinear optical response of a gold surface in the visible range: A study by two-color sum-frequency generation spectroscopy. I. Experimental determination.

    Science.gov (United States)

    Dalstein, L; Revel, A; Humbert, C; Busson, B

    2018-04-07

    We experimentally determine the effective nonlinear second-order susceptibility of gold over the visible spectral range. To reach that goal, we probe by vibrational two-color sum-frequency generation spectroscopy the methyl stretching region of a dodecanethiol self-assembled monolayer adsorbed on a gold film. The sum-frequency generation spectra show a remarkable shape reversal when the visible probe wavelength is tuned from 435 to 705 nm. After correcting from Fresnel effects, the methyl stretching vibrations serve as an internal reference, allowing to extract the dispersion of the absolute phase and relative amplitude of the effective nonlinear optical response of gold in the visible range.

  14. Controlling the Branching Ratio of Photoionization Products under Two-Color Excitation: Competition between ac Stark Splitting and Two-Path Interference

    International Nuclear Information System (INIS)

    Nakajima, T.; Zhang, J.; Lambropoulos, P.; Lambropoulos, P.

    1997-01-01

    We investigate the variation of the photoionization yields into different ionic channels by means of the one-photon-near-resonant two-photon ionization scheme under two-color excitation. We present a general formulation and the results of specific calculations pertaining to the Ca atom with realistic parameters. A significant change of the ionization into Ca + 4s , 3d , and 4p channels has been observed as a detuning is varied, which agrees qualitatively well with the observation by Wang, Chen, and Elliott [Phys.Rev.Lett.77, 2416 (1996)] for the Ba atom. The importance of the laser intensity effects is also addressed. copyright 1997 The American Physical Society

  15. Blue and Orange Two-Color CW Laser Based on Single-Pass Second-Harmonic and Sum-Frequency Generation in MgO:PPLN

    Directory of Open Access Journals (Sweden)

    Dismas K. Choge

    2018-04-01

    Full Text Available We demonstrate a compact blue and orange-two color continuous wave laser source emitting at 487 nm and from 597.4 to 600.3 nm, respectively. The temperature tunable coherent orange radiation is achieved by frequency mixing 974 nm laser diode (LD and a C-band amplified spontaneous emission laser source while the temperature insensitive blue radiation is generated by second-order quasi-phase-matching frequency doubling of 974 nm LD. We implement the simultaneous nonlinear processes in a single magnesium oxide doped periodically poled lithium niobate bulk crystal without the need of an aperiodic design.

  16. P1-9: Relationship between Color Shifts in Land's Two-Color Method and Higher- and Lower-Level Visual Information

    Directory of Open Access Journals (Sweden)

    Saki Iwaida

    2012-10-01

    Full Text Available Land's two-color method gives rise to apparent full-color perception, even though only two colors (e.g., red and gray are used. Previous studies indicate that chromatic adaptation, color memory, and inductive effects contribute to the shifts of color perception from real to illusory colors (e.g., Kuriki, 2006 Vision Research 46 3055–3066. This paper investigates the relationship between the color shifts induced by Land images and the skewness of the luminance histogram. In Experiment 1, several Land images are created based on a yellow ball, and the magnitude of the color shifts of the images are measured. The results of Experiment 1 show a significant correlation between the magnitude of the color shifts and skewness, suggesting that skewness is critical for the color shifts. In Experiment 2, we test the hypothesis that color shifts depends on just skewness; the color shifts should be invariant even if the Land images are scrambled. However, the results of Experiment 2 demonstrate that scrambled Land images exhibit less intense color shifts, suggesting that color shifts are determined by the object's overall shape or surface gloss, not just skewness. Taken together, we conclude that both low-level visual processes, such as those associated with luminance histogram skew, and high-level cognitive functions, such as object interpretation or understanding of surface gloss, are involved in the color shift of Land images.

  17. MIDCOURSE SPACE EXPERIMENT VERSUS IRAS TWO-COLOR DIAGRAMS AND THE CIRCUMSTELLAR ENVELOPE-SEQUENCE OF OXYGEN-RICH LATE-TYPE STARS

    International Nuclear Information System (INIS)

    Sjouwerman, Lorant O.; Capen, Stephanie M.; Claussen, Mark J.

    2009-01-01

    We present Midcourse Space Experiment (MSX) two-color diagrams that can be used to characterize circumstellar environments of sources with good quality MSX colors in terms of IRAS color regions for oxygen-rich stars. With these diagrams, we aim to provide a new tool that can be used to study circumstellar environments and to improve detection rates for targeted surveys for circumstellar maser emission similar to the IRAS two-color diagram. This new tool is especially useful for regions in the sky where IRAS was confused, in particular in the Galactic plane and bulge region. Unfortunately, using MSX colors alone does not allow one to distinguish between carbon-rich and oxygen-rich objects. An application of this tool on 86 GHz SiO masers shows that for this type of masers an instantaneous detection rate of 60% to 80% can be achieved if target sources are selected according to MSX color (region). Our investigations may have revealed an error in the MSX point source catalog version 2.3. That is, the photometry of the 21.3 μm (MSX E filter) band for most weak 8.28 μm (or MSX A filter) band sources seems off by about a factor 2 (0.5-1 mag too bright).

  18. Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Martín, M. J.; Mantilla, J. M.; del Campo, D.; Hernanz, M. L.; Pons, A.; Campos, J.

    2017-09-01

    The evolving mise en pratique for the definition of the kelvin (MeP-K) [1, 2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Español de Metrología (CEM), in collaboration with the Instituto de Óptica of Consejo Superior de Investigaciones Científicas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.

  19. A calorimetric particle detector using an iridium superconducting phase transition thermometer

    International Nuclear Information System (INIS)

    Frank, M.; Dummer, D.; Cooper, S.; Igalson, J.; Proebst, F.; Seidel, W.

    1994-01-01

    We report on a calorimetric particles detector consisting of an 18.3 g silicon crystal and an iridium superconducting phase transition thermometer. The cryogenic calorimeter and the associated apparatus are described in detail. The pulses from irradiation with an α-particle source have a large unexpected overshoot in addition to the component expected from a naive thermal model. The pulse height spectrum displays an energy resolution of 1 percent FWHM at 6 MeV and good linearity. The noise, electrothermal feedback, and position dependence are discussed. (orig.)

  20. Germanium thermometers in the temperature range .1000K to 4.20K

    International Nuclear Information System (INIS)

    Hsieh, S.Y.; Sanchez, D.H.

    1974-01-01

    The sensitivity characteristics of two germanium thermometers that proved to be convenient sensors in the temperature range from .100 0 K to 4.2 0 K, are described. Their resistances change from about 8 x 10 5 ohms at .100 0 K to about 100 ohms at 4.2 0 K. The calibration curves were fitted to natural spline functions of order 3 in the whole range of temperatures. These functions give less than half millidegree standard dispersion against 15 millidegree standard dispersion when usual polynomial interpolations are used. It is discussed what spline functions are, and compare the goodness of spline interpolation with polynomial methods [pt

  1. Determination of response time of resistance thermometers by in situ measurements

    International Nuclear Information System (INIS)

    Goncalves, I.M.P.; Soares, A.J.

    1986-01-01

    The loop-current-step-response test provides a mean for determining the time constant of resistance thermometers. The test consists in heating the sensor a few degrees above ambient temperature by causing a step perurbation in the electric current that flows through the sensor leads. The developed mathematical transformation permits to use data collected during the internal heating transient to predict the sensor response to perturbations in fluid temperature. Experimental data obtained show that time constant determined by this method is within 15 percent of the true value. (Author) [pt

  2. Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs.

    Science.gov (United States)

    Sousa, Marlos G; Carareto, Roberta; Pereira-Junior, Valdo A; Aquino, Monally C C

    2011-04-01

    Although the rectal mucosa remains the traditional site for measuring body temperature in dogs, an increasing number of clinicians have been using auricular temperature to estimate core body temperature. In this study, 88 mature healthy dogs had body temperatures measured with auricular and rectal thermometers. The mean temperature and confidence intervals were similar for each method, but Bland-Altman plots showed high biases and limits of agreement unacceptable for clinical purposes. The results indicate that auricular and rectal temperatures should not be interpreted interchangeably.

  3. A monocrystal of 59Co as a nuclear orientation thermometer in neutron experiments with oriented targets

    International Nuclear Information System (INIS)

    Fasoli, U.; Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.

    1980-01-01

    An apparatus for measuring temperatures in the millikelvin region is described based on the 'deformation effect' on fast neutron transmission through an aligned 59 Co monocrystal, employing a 252 Cf pill as the neutron source. A statistical accuracy of a few percent in a few minutes is obtainable with a heat input of some tens of pW. The apparatus is suitable in neutron experiments with oriented targets when the gamma-ray background hinders the use of gamma-ray anisotropy thermometers. In these and similar cases, in which the temperature must be held constant for long periods, the large heat capacity of the cobalt sample is not a drawback. (orig.)

  4. Preliminary Results on New Prototypes of Precision Rh-0.5at%Fe Resistance Thermometers of Chinese Production

    Science.gov (United States)

    Pavese, F.; Szmyrka-Grzebyk, A.; Lipinski, L.; Manuszkiewicz, H.; Qiu, Ping; Zhang, Jin Tao; Lin, Peng; Li, Xing Wei

    2008-02-01

    Given the practical impossibility of obtaining new precision Rh-0.5at%Fe resistance thermometers in recent years, the possible re-starting of the production of such thermometers in Yunnan (China) was explored by Istituto Nazionale di Ricerca Metrologica (INRIM). Ten prototypes of the new production were made available in early 2006. The paper reports the preliminary data from the testing performed to date on these prototypes at National Institute of Metrology (NIM) and Instytut Niskich Temperatur i Badan Strukturalnych (INTiBS). Although a problem with the alloy composition was detected, the reproducibility results on thermal cycling are very encouraging. Resistance-temperature ( R- T) characteristics below 30 K, though not identical with those of similar thermometers formerly available from Tinsley and VNIIFTRI, are still suitable for accurate metrology.

  5. Noise thermometer

    Energy Technology Data Exchange (ETDEWEB)

    Von Brixy, H. [Forschungszentrum Juelich GmbH (Germany); Kakuta, Tsunemi

    1996-03-01

    The noise thermometry (NT) is a temperature measuring method by which the absolute temperature measurement can be performed with a very high accuracy and without any influence of ambient environments and of the thermal history of its NT sensor (electric resistor). Hence it is quite suitable for application as a standard thermometry to the in-situ temperature calibration of incore thermocouples. The KFA Juelich had played a pioneering role in the development of NT and applied the results successfully to the AVR for testing its feasibility. In this report, all about the NT including its principle, sensor elements and system configurations are presented together with the experiences in the AVR and the results of investigation to apply it to high temperature measurement. The NT can be adopted as a standard method for incore temperature measurement and in situ temperature calibration in the HTTR. (author). 85 refs.

  6. Kitchen Thermometers

    Science.gov (United States)

    ... or in bird) 165 Eggs and Egg Dishes Eggs Cook until yolk and white are firm Egg dishes 160 Leftovers and Casseroles 165 *These temperatures are recommended for consumer cooking. They are not intended for processing, institutional, or ...

  7. Ionic thermometers

    International Nuclear Information System (INIS)

    Strnad, M.

    1975-01-01

    An original method of temperature measurement based on conductivity changes near the phase transition point of ionic compounds and suitable for the range from 200 to 700 0 C according to the thermometric compound used, is given. By choosing between two approaches it is posible to evaluate either a discrete value of temperature or continuous measurement in a range to about 50 0 C below the phase transition point of thermometric compounds. The extreme nonlinearity of conductivity of the chosen group of ionic crystals used as well as the technical applications developed in the laboratories have not previously been published. The aim of the research is the application of this measuring method for temperature indication in nuclear reactors. Preliminary tests in radiation fields in an experimental reactor are yielding a real hope in this direction. (author)

  8. Noise thermometer

    International Nuclear Information System (INIS)

    Von Brixy, H.; Kakuta, Tsunemi.

    1996-03-01

    The noise thermometry (NT) is a temperature measuring method by which the absolute temperature measurement can be performed with a very high accuracy and without any influence of ambient environments and of the thermal history of its NT sensor (electric resistor). Hence it is quite suitable for application as a standard thermometry to the in-situ temperature calibration of incore thermocouples. The KFA Juelich had played a pioneering role in the development of NT and applied the results successfully to the AVR for testing its feasibility. In this report, all about the NT including its principle, sensor elements and system configurations are presented together with the experiences in the AVR and the results of investigation to apply it to high temperature measurement. The NT can be adopted as a standard method for incore temperature measurement and in situ temperature calibration in the HTTR. (author). 85 refs

  9. Development of a superconducting transition edge thermometer for calorimetric detection of heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Meier, J; Boehmer, W; Egelhof, P; Henning, W; Kienlin, A v [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany) Mainz Univ. (Germany). Inst. fuer Physik; Shepard, K W [Argonne National Lab., IL (United States)

    1991-10-01

    A low temperature bolometer for the calorimetric detection of heavy ions was constructed and tested. An aluminium thin-film microstrip, patterned in a meander-line structure by photolithographic techniques, serves as superconducting transition edge thermometer on a sapphire absorber. A transition width {delta}T of the thermometer of the order of some mK, and a resistance of up to R{sub c} = 60 k{Omega} at the working point (T{sub c} {approx equal} 1.5 K) is achieved. In tests with {alpha}-particles signals of typically 1 V pulseheight after the preamplifier and decaytimes around hundred {mu}s were observed. For 5.5 MeV {alpha}-particles the measured energy resolution is {Delta}E = 50 keV, corresponding to a temperature resolution of about 1 {mu}K. First measurements were performed with {sup 20}Ne ions (E = 116 MeV). The dependence of the pulseheight and the FWHM on the working point were investigated and qualitatively explained. The best energy resolution was {Delta}E = 2.6 MeV; most probably the present limitations are determined by the temperature stabilization. (orig.).

  10. Bilateral comparison for determining the dynamic characteristic values of contact thermometers in fluids

    Directory of Open Access Journals (Sweden)

    S. Augustin

    2018-05-01

    Full Text Available In applicable standards and sets of rules (VDI/VDE, 2014; DIN, 2010, 2017, recommendations are made concerning the types of experiments for determining the dynamic parameters in fluids (flowing water and flowing air under well-defined conditions. In the data sheets of the thermometer manufacturers, quite different specifications can be found, such as time percentage values or time constants. Only a few thermometer manufacturers specify the medium and flow conditions under which these parameters have been determined. Above all, it is not common practice to indicate a measurement uncertainty for the dynamic parameters found. In Augustin et al. (2017, a first model for the indication of the measurement uncertainty of dynamic parameters in flowing air was presented.The present paper describes the results of a bilateral comparison made for the first time for determining dynamic parameters in the laboratories of the JUMO GmbH & Co. KG Fulda company and at the Institute of Process Measurement and Sensor Technology of the TU Ilmenau. In doing so, two type-N thermocouples with different diameters were investigated in experimental facilities with flowing water and flowing air. Subsequently, the dynamic parameters found were compared with each other. The differences revealed mainly resulted from plant-specific parameters.

  11. Modified ultrafast thermometer UFT-M and temperature measurements during Physics of Stratocumulus Top (POST

    Directory of Open Access Journals (Sweden)

    W. Kumala

    2013-08-01

    Full Text Available A modified UFT-M version of the ultrafast airborne thermometer UFT, aimed at in-cloud temperature measurements, was designed for the Physics of Stratocumulus Top (POST field campaign. Improvements in its construction resulted in the sensor's increased reliability, which provided valuable measurements in 15 of the 17 flights. Oversampling the data allowed for the effective correction of the artefacts resulting from the interference with electromagnetic transmissions from on-board avionic systems and the thermal noise resulting from the sensor construction. The UFT-M records, when averaged to the 1.4 and 55 m resolutions, compared to the similar records of a thermometer in a Rosemount housing, indicate that the housing distorts even low-resolution airborne temperature measurements. Data collected with the UFT-M during the course of POST characterise the thermal structure of stratocumulus and capping inversion with the maximum resolution of ~1 cm. In this paper, examples of UFT-M records are presented and discussed.

  12. Infrared astronomy

    International Nuclear Information System (INIS)

    Setti, G.; Fazio, G.

    1978-01-01

    This volume contains lectures describing the important achievements in infrared astronomy. The topics included are galactic infrared sources and their role in star formation, the nature of the interstellar medium and galactic structure, the interpretation of infrared, optical and radio observations of extra-galactic sources and their role in the origin and structure of the universe, instrumental techniques and a review of future space observations. (C.F.)

  13. Generation and amplification of sub-THz radiation in a rare gases plasma formed by a two-color femtosecond laser pulse

    Science.gov (United States)

    Bogatskaya, A. V.; Volkova, E. A.; Popov, A. M.

    2018-06-01

    A new approach to constructing the source of radiation in the sub-THz frequency range is discussed. It is based on the strong-field ionization of heavy rare gases with Ramsauer minimum in the transport cross-section by a two-color () femtosecond laser pulse. Then a four-photon nonlinear process ( are the frequencies from the spectral width of the pulse with frequency ω, and is the frequency from the spectral width of the second harmonic 2ω) with a transition to the initial state results in a low-frequency spontaneous emission that can be amplified in the strongly nonequilibrium laser plasma if the position of the photoelectron peaks is located in the region of growing energy transport cross-section.

  14. Selected cis- and trans-3-fluorostyrene rotamers studied by two-color resonant two-photon mass-analyzed threshold ionization spectroscopy

    Science.gov (United States)

    Wu, Pei Ying; Tzeng, Wen Bih

    2015-10-01

    We applied two-color resonant two-photon ionization and mass-analyzed threshold ionization techniques to record the vibronic, photoionization efficiency, and cation spectra of the selected rotamers of 3-fluorostyrene. The adiabatic ionization energies of cis- and trans-3-fluorostyrene were determined to be 69 960 ± 5 and 69 856 ± 5 cm-1, respectively. Cation vibrations 10a, 15, 6b, and 12 of both rotamers have been found to have frequencies of 218, 404, 452, and 971 cm-1, respectively. This finding shows that the relative orientation of the vinyl group with respect to the F atom does not affect these vibrations of the 3-fluorostyrene cation. Our one-dimensional potential energy surface calculations support that the cis-trans isomerization of 3-fluorostyrene does not occur under the present experimental conditions.

  15. Generation of Bright, Spatially Coherent Soft X-Ray High Harmonics in a Hollow Waveguide Using Two-Color Synthesized Laser Pulses.

    Science.gov (United States)

    Jin, Cheng; Stein, Gregory J; Hong, Kyung-Han; Lin, C D

    2015-07-24

    We investigate the efficient generation of low-divergence high-order harmonics driven by waveform-optimized laser pulses in a gas-filled hollow waveguide. The drive waveform is obtained by synthesizing two-color laser pulses, optimized such that highest harmonic yields are emitted from each atom. Optimization of the gas pressure and waveguide configuration has enabled us to produce bright and spatially coherent harmonics extending from the extreme ultraviolet to soft x rays. Our study on the interplay among waveguide mode, atomic dispersion, and plasma effect uncovers how dynamic phase matching is accomplished and how an optimized waveform is maintained when optimal waveguide parameters (radius and length) and gas pressure are identified. Our analysis should help laboratory development in the generation of high-flux bright coherent soft x rays as tabletop light sources for applications.

  16. Tympanic, Infrared Skin, and Temporal Artery Scan Thermometers Compared with Rectal Measurement in Children: A Real-Life Assessment

    Directory of Open Access Journals (Sweden)

    Karel Allegaert, MD, PhD

    2014-12-01

    Conclusions: All noninvasive techniques underperformed compared with rectal measurement. The temporal artery scan deviations were smallest, but all noninvasive techniques overestimate lower temperatures and underestimate higher temperatures compared with rectal measurement. In our hands, temporal artery scan measurement seems to be second best, but not yet ideal.

  17. Comparison of soot formation for diesel and jet-a in a constant volume combustion chamber using two-color pyrometry

    KAUST Repository

    Jing, Wei

    2014-04-01

    The measurement of the two-color line of sight soot and KL factor for NO.2 diesel and jet-A fuels was conducted in an optical constant volume combustion chamber by using a high speed camera under 1000 K ambient temperature and varied oxygen concentration conditions. The ambient conditions were set as follows: four oxygen cases including 10%, 15%, 18% and 21% at 1000 K ambient temperature. KL factor and soot temperature were determined based on the two-color pyrometry technique using two band-pass filters with wavelengths of 650 nm and 550 nm. The results show that low soot temperature is observed in the upstream inner flame along the centerline, which is surrounded by high soot temperature regions, and a high KL factor is found in the same region with a low soot temperature. The results under different times suggest that soot temperature is higher for high O2 conditions during the entire flame development; meanwhile, both integrated KL factor and soot area decrease with the increase of O2 concentration. The two fuels share a similar trend of soot temperature and KL factor, however, diesel flame has a higher soot temperature and a larger high soot temperature area compared to jet-A flame. On the other hand, diesel flame shows a lower soot level during the quasi-steady state with a higher total soot level at the end of the combustion under low O2 conditions. A lower O2 concentration range from 10% to 15% is expected to have the possibility to achieve a simultaneous reduction of soot and NOx in sooting flames under the 1000 K ambient temperature condition. Copyright © 2014 SAE International.

  18. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

    Science.gov (United States)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; Harding, E. C.; Jennings, C. A.; Lamppa, D. C.; Loisel, G. P.; Martin, M. R.; Robertson, G. K.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Weis, M. R.; Porter, J. L.; McBride, R. D.

    2017-10-01

    Many experiments on Sandia National Laboratories' Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [ C R = r i ( 0 ) / r i ( t ) ] using the 6.151-keV backlighter system were too opaque to identify the inner radius r i of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

  19. Infrared thermography

    CERN Document Server

    Meola, Carosena

    2012-01-01

    This e-book conveys information about basic IRT theory, infrared detectors, signal digitalization and applications of infrared thermography in many fields such as medicine, foodstuff conservation, fluid-dynamics, architecture, anthropology, condition monitoring, non destructive testing and evaluation of materials and structures.

  20. Assessing the accuracy of globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate

    Science.gov (United States)

    Khrit, N. G.; Alghoul, M. A.; Sopian, K.; Lahimer, A. A.; Elayeb, O. K.

    2017-11-01

    Assessing outdoor human thermal comfort and urban climate quality require experimental investigation of microclimatic conditions and their variations in open urban spaces. For this, it is essential to provide quantitative information on air temperature, humidity, wind velocity and mean radiant temperature. These parameters can be quantified directly except mean radiant temperature (Tmrt). The most accurate method to quantify Tmrt is integral radiation measurements (3-D shortwave and long-wave) which require using expensive radiometer instruments. To overcome this limitation the well-known globe thermometer method was suggested to calculate Tmrt. The aim of this study was to assess the possibility of using indoor globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate. Globe thermometer method using small and large sizes of black-painted copper globes (50mm, 150mm) were used to estimate Tmrt and compare it with the reference Tmrt estimated by integral radiation method. The results revealed that the globe thermometer method considerably overestimated Tmrt during the middle of the day and slightly underestimated it in the morning and late evening. The difference between the two methods was obvious when the amount of incoming solar radiation was high. The results also showed that the effect of globe size on the estimated Tmrt is mostly small. Though, the estimated Tmrt by the small globe showed a relatively large amount of scattering caused by rapid changes in radiation and wind speed.

  1. Dual-sensing porphyrin-containing copolymer nanosensor as full-spectrum colorimeter and ultra-sensitive thermometer.

    Science.gov (United States)

    Yan, Qiang; Yuan, Jinying; Kang, Yan; Cai, Zhinan; Zhou, Lilin; Yin, Yingwu

    2010-04-28

    A porphyrin-containing copolymer has dual-sensing in response to metal ions and temperature as a novel nanosensor. Triggered by ions, the sensor exhibits full-color tunable behavior as a cationic detector and colorimeter. Responding to temperature, the sensor displays an "isothermal" thermochromic point as an ultra-sensitive thermometer.

  2. Tympanic ear thermometer assessment of body temperature among patients with cognitive disturbances. An acceptable and ethically desirable alternative?

    Science.gov (United States)

    Aadal, Lena; Fog, Lisbet; Pedersen, Asger Roer

    2016-12-01

    Investigation of a possible relation between body temperature measurements by the current generation of tympanic ear and rectal thermometers. In Denmark, a national guideline recommends the rectal measurement. Subsequently, the rectal thermometers and tympanic ear devices are the most frequently used and first choice in Danish hospital wards. Cognitive changes constitute challenges with cooperating in rectal temperature assessments. With regard to diagnosing, ethics, safety and the patients' dignity, the tympanic ear thermometer might comprise a desirable alternative to rectal noninvasive measurement of body temperature during in-hospital-based neurorehabilitation. A prospective, descriptive cohort study. Consecutive inclusion of 27 patients. Linear regression models were used to analyse 284 simultaneous temperature measurements. Ethical approval for this study was granted by the Danish Data Protection Agency, and the study was completed in accordance with the Helsinki Declaration 2008. About 284 simultaneous rectal and ear temperature measurements on 27 patients were analysed. The patient-wise variability of measured temperatures was significantly higher for the ear measurements. Patient-wise linear regressions for the 25 patients with at least three pairs of simultaneous ear and rectal temperature measurements showed large interpatient variability of the association. A linear relationship between the rectal body temperature assessment and the temperature assessment employing the tympanic thermometer is weak. Both measuring methods reflect variance in temperature, but ear measurements showed larger variation. © 2016 Nordic College of Caring Science.

  3. Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer

    International Nuclear Information System (INIS)

    Becerro, E.; Carreira, M.

    1968-01-01

    The solubility problems raised by some components of the polymeric residue of irradiated polyphenolic coolants, which make it necessary to operate with very small samples, have been solved by means of a differential cryoscopic technique using a thermoelectric thermometer (thermal) as sensitive element. The method is based on the direct measurement of the difference between the freezing points of the investigated solution and of a reference solution whose concentration may be changed at will. The change of Δ V (mV) versus c(molal) is linear, the equivalent point being determined either analytically or graphically depending on the required accuracy. The method has been tested by measurements on pure polyphenyls, using diphenyl ether as solvent. It has been also applied to the main prospective coolants for the DON reactor. Working with 10 2 molal solutions the accuracy is better than ± 2 per cent. (Author) 2 refs

  4. Development of a platinum resistance thermometer on the silicon substrate for phase change studies

    International Nuclear Information System (INIS)

    Cai, Qingjun; Chen, Ya-Chi; Tsai, Chialun; DeNatale, Jeffrey F

    2012-01-01

    Resistance temperature detectors are commonly used measurement sensors in heat transfer studies. In many resistance temperature detectors, the platinum resistance thermometer (PRT) is chemically stable, has a wide temperature measurement range and possesses high measurement accuracy. In phase change studies of carbon nanotubes, bi-porous structures for microelectronic thermal management, 100 nm thick PRTs are developed on silicon substrates with 10 nm titanium adhesive to achieve precise and interface-free temperature measurements. After an annealing at 375 °C, the PRT samples are calibrated at a temperature range from 20 to 180 °C. Measurement hysteresis of temperature appears in thermal cycles. Electrical resistance tends to become low during all heating periods, which establishes the maximum measurement deviation of 10 °C. Experimental results from two different thin-film PRTs indicate that accurate and repeatable temperature measurements can be achieved by either reducing heating speed or using data in the cooling period. (paper)

  5. Magnetic Thermometer: Thermal effect on the Agglomeration of Magnetic Nanoparticles by Magnetic field

    Science.gov (United States)

    Jin, Daeseong; Kim, Hackjin

    2018-03-01

    We have investigated the agglomeration of magnetite nanoparticles in the aqueous solution under magnetic field by measuring temporal change of magnetic weight. The magnetic weight corresponds to the force due to the magnetization of magnetic materials. Superparamagnetic magnetite nanoparticles are synthesized and used in this work. When the aqueous solution of magnetite nanoparticle is placed under magnetic field, the magnetic weight of the sample jumps instantaneously by Neel and Brown mechanisms and thereafter increases steadily following a stretched exponential function as the nanoparticles agglomerate, which results from the distribution of energy barriers involved in the dynamics. Thermal motions of nanoparticles in the agglomerate perturb the ordered structure of the agglomerate to reduce the magnetic weight. Fluctuation of the structural order of the agglomerate by temperature change is much faster than the formation of agglomerate and explained well with the Boltzmann distribution, which suggests that the magnetic weight of the agglomerate works as a magnetic thermometer.

  6. International comparison of resistance thermometers between NMIs from Spain, Mexico and Andean countries

    Science.gov (United States)

    del Campo, D.; Ruiz, V. C.; Méndez-Lango, E.; Córdova, L.; von Borries, E.; Sánchez, C. A.; Arévalo, A.; Aguilera, B.; Guillén, E.; Cabrera, C.; Quintana, L.

    2013-09-01

    An international comparison on semi-standard Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Mexico and the Andean Countries (Bolivia, Colombia, Ecuador, Peru and Venezuela) began in 2004 and was successfully completed in 2005. Two PRTs were circulated (hand carried) and compared from -40 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, was the pilot laboratory and the Centro Nacional de Metrología (Mexican NMI), CENAM, was the co-pilot laboratory. This paper shows the details of the comparison and the final results as they were presented in the approved final report of the comparison in September of 2005.

  7. Measurement of temperature distributions in large pool fires with the use of directional flame thermometers

    International Nuclear Information System (INIS)

    Koski, Jorman A.

    2000-01-01

    Temperatures inside the flame zone of large regulatory pool fires measured during tests of radioactive materials packages vary widely with both time and position. Measurements made with several Directional Flame Thermometers, in which a thermocouple is attached to a thin metal sheet that quickly approaches flame temperatures, have been used to construct fire temperature distributions and cumulative probability distributions. As an aid to computer simulations of these large fires, these distributions are presented. The distributions are constructed by sorting fire temperature data into bins 10 C wide. A typical fire temperature distribution curve has a gradual increase starting at about 600 C, with the number of observations increasing to a peak near 1000 C, followed by an abrupt decrease in frequency, with no temperatures observed above 1200 C

  8. Use of a Novel Two Color PALM Method to Examine Structural Properties of Drp1 Helical Rings during Mammalian Mitochondrial Fission In Situ

    Science.gov (United States)

    Rosenbloom, Alyssa Blair

    In this thesis, we accomplish two goals: 1) we develop a novel two color photoactivatable light microscopy (PALM) method for imaging in mammalian cells and 2) we explore our original biological question and discern the structural properties of the Drp1 helical ring during fission. We established that mitochondrial membranes can be distinguished with the available photoactivatable fluorescent protein mEos2. However, we were not able to use any of the published photoactivatable and photoswitchable green fluorescent proteins, predominantly because of an inability to identify individual fluorescent events due to rapidity of the photoswitiching. Based on published crystal structures, we created novel Dronpa variants with increasing steric hindrance around the chromophore, likely partially inhibiting the isomerization. We replaced Val157 with isoleucine, leucine, or phenyalanine. DronpaV157F showed no fluorescence and was discarded. DronpaV157I and DronpaV157L showed photoswitchable green fluorescence, with individual fluorescent events that were more easily discerned. DronpaV157L in particular had bright fluorescent events that were well separated when imaged in mammalian cells at 20 Hz. We named this new variant rsKame. Using PALM we successfully imaged rsKame expressed and localized to the mammalian mitochondrial inner membrane. With the novel photoswitchable fluorescent protein, rsKame, available, we returned to the development of a novel two color PALM method. We chose PAmCherry1 as the partner for rsKame since PAmCherry1 has distinct and well separated excitation/emission spectra from rsKame and is not activated by low 405 nm laser power density. We first imaged rsKame with 405 nm activation at (0.61 mW/mm2) and 488 nm activation/excitation (5.87 W/mm 2) to completion. We then imaged PAmCherry1 with increasing 405 nm activation (0.6-6.0 W/mm2) and 561 nm excitation (22 W/mm 2). With the novel PALM imaging method, we labeled the inner and outer mitochondrial

  9. Monitoring changes in body surface temperature associated with treadmill exercise in dogs by use of infrared methodology.

    Science.gov (United States)

    Rizzo, Maria; Arfuso, Francesca; Alberghina, Daniela; Giudice, Elisabetta; Gianesella, Matteo; Piccione, Giuseppe

    2017-10-01

    The aim of this study was to evaluate the influence of moderate treadmill exercise session on body surface and core temperature in dog measured by means of two infrared instruments. Ten Jack Russell Terrier/Miniature Pinscher mixed-breed dogs were subjected to 15min of walking, 10min of trotting and 10min of gallop. At every step, body surface temperature (T surface ) was measured on seven regions (neck, shoulder, ribs, flank, back, internal thigh and eye) using two different methods, a digital infrared camera (ThermaCam P25) and a non-contact infrared thermometer (Infrared Thermometer THM010-VT001). Rectal temperature (T rectal ) and blood samples were collected before (T0) and after exercise (T3). Blood samples were tested for red blood cell (RBC), hemoglobin concentration (Hb) and hematocrit (Hct). A significant effect of exercise in all body surface regions was found, as measured by both infrared methods. The temperature obtained in the eye and the thigh area were higher with respect to the other studied regions throughout the experimental period (Ptemperature values measured by infrared thermometer was found in neck, shoulder, ribs, flank, back regions respect to the values obtained by digital infrared camera (Ptemperatures are influenced by physical exercise probably due to muscle activity and changes in blood flow in dogs. Both infrared instruments used in this study have proven to be useful in detecting surface temperature variations of specific body regions, however factors including type and color of animal hair coat must be taken into account in the interpretation of data obtained by thermography methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Photoionization and trans-to-cis isomerization of β-cyclodextrin-encapsulated azobenzene induced by two-color two-laser-pulse excitation.

    Science.gov (United States)

    Takeshita, Tatsuya; Hara, Michihiro

    2018-03-15

    Azobenzene (1) and the complex resulting from the incorporation of 1 with cyclodextrin (1/CD) are attractive for light-driven applications such as micromachining and chemical biology tools. The highly sensitive photoresponse of 1 is crucial for light-driven applications containing both 1 and 1/CD to reach their full potential. In this study, we investigated the photoionization and trans-to-cis isomerization of 1/CD induced by one- and two-color two-laser pulse excitation. Photoionization of 1/CD, which was induced by stepwise two-photon absorption, was observed using laser pulse excitation at 266nm. Additionally, simultaneous irradiation with 266 and 532nm laser pulses increased the trans-to-cis isomerization yield (Υ t→c ) by 27%. It was concluded that the increase in Υ t→c was caused by the occurrence of trans-to-cis isomerization in the higher-energy singlet state (S n ), which was reached by S 1 →S n transition induced by laser pulse excitation at 532nm. The results of this study are potentially applicable in light-driven applications such as micromachining and chemical biology tools. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. The mechanics of unrest at Long Valley caldera, California: 1. Modeling the geometry of the source using GPS, leveling and two-color EDM data

    Science.gov (United States)

    Battaglia, Maurizio; Segall, P.; Murray, J.; Cervelli, Peter; Langbein, J.

    2003-01-01

    We surveyed 44 existing leveling monuments in Long Valley caldera in July 1999, using dual frequency global positioning system (GPS) receivers. We have been able to tie GPS and leveling to a common reference frame in the Long Valley area and computed the vertical deformation by differencing GPS-based and leveled orthometric heights. The resurgent dome uplifted 74??7 cm from 1975 to 1999. To define the inflation source, we invert two-color EDM and uplift data from the 1985-1999 unrest period using spherical or ellipsoidal sources. We find that the ellipsoidal source satisfies both the vertical and horizontal deformation data, whereas the spherical point source cannot. According to our analysis of the 1985-1999 data, the main source of deformation is a prolate ellipsoid located beneath the resurgent dome at a depth of 5.9 km (95% bounds of 4.9-7.5 km). This body is vertically elongated, has an aspect ratio of 0.475 (95% bounds are 0.25-0.65) and a volume change of 0.086 km3 (95% bounds are 0.06-0.13 km3). Failure to account for the ellipsoidal nature of the source biases the estimated source depth by 2.1 km (35%), and the source volume by 0.038 km3 (44%). ?? 2003 Elsevier B.V. All rights reserved.

  12. Design and initial operation of a two-color soft x-ray camera system on the Compact Toroidal Hybrid experiment

    International Nuclear Information System (INIS)

    Herfindal, J. L.; Dawson, J. D.; Ennis, D. A.; Hartwell, G. J.; Loch, S. D.; Maurer, D. A.

    2014-01-01

    A multi-camera soft x-ray diagnostic has been developed to measure the equilibrium electron temperature profile and temperature fluctuations due to magnetohydrodynamic activity on the Compact Toroidal Hybrid experiment. The diagnostic consists of three separate cameras each employing two 20-channel diode arrays that view the same plasma region through different beryllium filter thicknesses of 1.8 μm and 3.0 μm allowing electron temperature measurements between 50 eV and 200 eV. The Compact Toroidal Hybrid is a five-field period current-carrying stellarator, in which the presence of plasma current strongly modifies the rotational transform and degree of asymmetry of the equilibrium. Details of the soft x-ray emission, effects of plasma asymmetry, and impurity line radiation on the design and measurement of the two-color diagnostic are discussed. Preliminary estimates of the temperature perturbation due to sawtooth oscillations observed in these hybrid discharges are given

  13. Unraveling the rat blood genome-wide transcriptome after oral administration of lavender oil by a two-color dye-swap DNA microarray approach

    Directory of Open Access Journals (Sweden)

    Motohide Hori

    2016-06-01

    Full Text Available Lavender oil (LO is a commonly used essential oil in aromatherapy as non-traditional medicine. With an aim to demonstrate LO effects on the body, we have recently established an animal model investigating the influence of orally administered LO in rat tissues, genome-wide. In this brief, we investigate the effect of LO ingestion in the blood of rat. Rats were administered LO at usual therapeutic dose (5 mg/kg in humans, and following collection of the venous blood from the heart and extraction of total RNA, the differentially expressed genes were screened using a 4 × 44-K whole-genome rat chip (Agilent microarray platform; Agilent Technologies, Palo Alto, CA, USA in conjunction with a two-color dye-swap approach. A total of 834 differentially expressed genes in the blood were identified: 362 up-regulated and 472 down-regulated. These genes were functionally categorized using bioinformatics tools. The gene expression inventory of rat blood transcriptome under LO, a first report, has been deposited into the Gene Expression Omnibus (GEO: GSE67499. The data will be a valuable resource in examining the effects of natural products, and which could also serve as a human model for further functional analysis and investigation.

  14. Two-color fluorescence analysis of individual virions determines the distribution of the copy number of proteins in herpes simplex virus particles.

    Science.gov (United States)

    Clarke, Richard W; Monnier, Nilah; Li, Haitao; Zhou, Dejian; Browne, Helena; Klenerman, David

    2007-08-15

    We present a single virion method to determine absolute distributions of copy number in the protein composition of viruses and apply it to herpes simplex virus type 1. Using two-color coincidence fluorescence spectroscopy, we determine the virion-to-virion variability in copy numbers of fluorescently labeled tegument and envelope proteins relative to a capsid protein by analyzing fluorescence intensity ratios for ensembles of individual dual-labeled virions and fitting the resulting histogram of ratios. Using EYFP-tagged capsid protein VP26 as a reference for fluorescence intensity, we are able to calculate the mean and also, for the first time to our knowledge, the variation in numbers of gD, VP16, and VP22 tegument. The measurement of the number of glycoprotein D molecules was in good agreement with independent measurements of average numbers of these glycoproteins in bulk virus preparations, validating the method. The accuracy, straightforward data processing, and high throughput of this technique make it widely applicable to the analysis of the molecular composition of large complexes in general, and it is particularly suited to providing insights into virus structure, assembly, and infectivity.

  15. A Comparison of Surface Infrared with Rectal Thermometry in Dogs.

    Science.gov (United States)

    Omóbòwálé, T O; Ogunro, B N; Odigie, E A; Otuh, P I; Olugasa, B O

    2017-12-30

    Accurate determination of temperature is crucial in the diagnosis of febrile conditions. Although fewer techniques have proven as useful and reliable a predictor of core body temperature as the rectal thermometry, the process of obtaining the rectal temperature could be stressful in dogs. The infrared thermometry is a noncontact device used for measuring body temperature, with advantages which include speed, convenience, and reduced stress to the animals and reduced occupational risks to the animal handler. Therefore, there is the need to assess the consistency and agreement between non-contact infrared thermometry and traditional rectal thermometry in body temperature estimation. This study compared and assessed the sensitivity of non-contact infrared thermometer used on the forehead and nasal regions respectively with that of a rectal thermometer in dogs for body temperature estimation. One hundred and thirty (130) dogs presented for veterinary attention at the Veterinary Teaching Hospital (VTH), University of Ibadan, Nigeria were enrolled in this study during August to September 2014, irrespective of sex, age, breed or health status. Temperatures of dogs presented at the clinic were obtained using both multiple non-contact infrared thermometric measures obtained in the nasal and frontal head regions; and by rectal temperature. A multivariate cross-matrix analysis was used to assess the difference in measurements between the rectal thermometry and non-contact infrared thermometry. Descriptive statistics was used to compare variation and trend regularity of the nasal and fore-head infrared thermometry. A logistic regression of the difference in measurements was computed at 95% confidence interval and P<0.05. The mean difference revealed that the rectal temperature was 5.330C higher than the non-contact infrared forehead-based temperature and 7.570C higher than nasal-based temperature measurements respectively. The Bland-Altman (B-A) plot showed that the 95% limits

  16. A Novel Flame Thermometer Based on the Doppler Width of Ro-Vibrational Transitions

    Science.gov (United States)

    1993-05-01

    flame thermometric technique based on the infrared spectroscopy of flame species is reported. It involves the use of a narrow linewidth (ɘ.001 cm-1...study. Output radiation from the laser diode is incident onto a parabolic aluminum mirror which collimates the beam and directs it into a monochromator...infrared beam. 5. SUMMARY AND CONCLUSIONS A novel flame thermometric technique has been developed which is based on the infrared spectroscopy of flame

  17. Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study

    Directory of Open Access Journals (Sweden)

    Smith Linda S

    2003-06-01

    Full Text Available Abstract Background As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1 to examine age, race, site as variables affecting temperature measurement in adults, and 2 to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. Methods Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120 of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F measured at oral, skin (simultaneous, immediately followed by rectal sites with four each mercury-glass (BD and Galinstan-glass (Geratherm thermometers; 10 minute dwell times. Results Participants averaged 61.6 years (SD 17.9, 188 pounds (SD 55.3; 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F: oral (0.142 – 0.265, axilla (0.167 – 0.339, groin (0.037 – 0.321, and rectal (-0.111 – 0.111. Race correlated with age, temperature readings each site and device. Conclusion Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered

  18. Comparison of Microchip Transponder and Noncontact Infrared Thermometry with Rectal Thermometry in Domestic Swine (Sus scrofa domestica)

    Science.gov (United States)

    Jara, Amanda L; Hanson, Jarod M; Gabbard, Jon D; Johnson, Scott K; Register, Emery T; He, Biao

    2016-01-01

    During disease outbreaks, core temperature is a useful health metric in swine, due to the presence of pyrexia especially during the acute phase of infection. Despite technologic advances in other facets of swine production and health management, rectal thermometry continues to be the ‘gold standard’ for measuring core body temperature. However, for various reasons, collecting rectal temperatures can be difficult and unsafe depending on the housing modality. In addition, the delay between insertion of the rectal thermometer and obtaining a reading can affect measurement accuracy, especially when the pig requires physical restraint. Clearly safer, faster, and more accurate and precise temperature acquisition methods that necessitate minimal or no handling of swine are needed. We therefore compared rectal thermometers, subcutaneous microchips, and an inexpensive handheld infrared thermometer by measuring the core body temperature of 24 male castrated piglets at random intervals over a 5-wk period. The core body temperature (mean ± 1 SD) was 39.3 ± 0.5 °C by rectal thermometry, 39.0 ± 0.7 °C by microchip transponder, and 34.3 ± 1.0 °C by infrared thermometry; these 3 values differed significantly. Although the readings obtain by using infrared thermometry were numerically lower than those from the other methods, it is arguably the safest method for assessing the core temperature of swine and showed strong relative correlation with rectal temperature. PMID:27657715

  19. Infrared laser diagnostics for ITER

    International Nuclear Information System (INIS)

    Hutchinson, D.P.; Richards, R.K.; Ma, C.H.

    1995-01-01

    Two infrared laser-based diagnostics are under development at ORNL for measurements on burning plasmas such as ITER. The primary effort is the development of a CO 2 laser Thomson scattering diagnostic for the measurement of the velocity distribution of confined fusion-product alpha particles. Key components of the system include a high-power, single-mode CO 2 pulsed laser, an efficient optics system for beam transport and a multichannel low-noise infrared heterodyne receiver. A successful proof-of-principle experiment has been performed on the Advanced Toroidal Facility (ATF) stellerator at ORNL utilizing scattering from electron plasma frequency satellites. The diagnostic system is currently being installed on Alcator C-Mod at MIT for measurements of the fast ion tail produced by ICRH heating. A second diagnostic under development at ORNL is an infrared polarimeter for Faraday rotation measurements in future fusion experiments. A preliminary feasibility study of a CO 2 laser tangential viewing polarimeter for measuring electron density profiles in ITER has been completed. For ITER plasma parameters and a polarimeter wavelength of 10.6 microm, a Faraday rotation of up to 26 degree is predicted. An electro-optic polarization modulation technique has been developed at ORNL. Laboratory tests of this polarimeter demonstrated a sensitivity of ≤ 0.01 degree. Because of the similarity in the expected Faraday rotation in ITER and Alcator C-Mod, a collaboration between ORNL and the MIT Plasma Fusion Center has been undertaken to test this polarimeter system on Alcator C-Mod. A 10.6 microm polarimeter for this measurement has been constructed and integrated into the existing C-Mod multichannel two-color interferometer. With present experimental parameters for C-Mod, the predicted Faraday rotation was on the order of 0.1 degree. Significant output signals were observed during preliminary tests. Further experiment and detailed analyses are under way

  20. Parent-Child Agreement Using the Spence Children's Anxiety Scale and a Thermometer in Children with Autism Spectrum Disorder

    Science.gov (United States)

    May, T.; Cornish, K.; Rinehart, N. J.

    2015-01-01

    Children with Autism Spectrum Disorder (ASD) experience high anxiety which often prompts clinical referral and requires intervention. This study aimed to compare parent and child reports on the Spence Children's Anxiety Scale (SCAS) and a child-reported “worry thermometer” in 88 children aged 8–13 years, 44 with ASD and 44 age, gender, and perceptual IQ matched typically developing children. There were no gender differences in child report on the SCAS and worry thermometers. Results indicated generally good correlations between parent and child self-reported SCAS symptoms for typically developing children but poor agreement in parent-child ASD dyads. The worry thermometer child-report did not reflect child or parent reports on the SCAS. Findings suggest 8–13-year-old children with ASD may have difficulties accurately reporting their anxiety levels. The clinical implications were discussed. PMID:25922765

  1. Bilateral Comparison of Mercury and Gallium Fixed-Point Cells Using Standard Platinum Resistance Thermometer

    Science.gov (United States)

    Bojkovski, J.; Veliki, T.; Zvizdić, D.; Drnovšek, J.

    2011-08-01

    The objective of project EURAMET 1127 (Bilateral comparison of triple point of mercury and melting point of gallium) in the field of thermometry is to compare realization of a triple point of mercury (-38.8344 °C) and melting point of gallium (29.7646 °C) between the Slovenian national laboratory MIRS/UL-FE/LMK and the Croatian national laboratory HMI/FSB-LPM using a long-stem 25 Ω standard platinum resistance thermometer (SPRT). MIRS/UL/FE-LMK participated in a number of intercomparisons on the level of EURAMET. On the other hand, the HMI/LPM-FSB laboratory recently acquired new fixed-point cells which had to be evaluated in the process of intercomparisons. A quartz-sheathed SPRT has been selected and calibrated at HMI/LPM-FSB at the triple point of mercury, the melting point of gallium, and the water triple point. A second set of measurements was made at MIRS/UL/FE-LMK. After its return, the SPRT was again recalibrated at HMI/LPM-FSB. In the comparison, the W value of the SPRT has been used. Results of the bilateral intercomparison confirmed that the new gallium cell of the HMI/LPM-FSB has a value that is within uncertainty limits of both laboratories that participated in the exercise, while the mercury cell experienced problems. After further research, a small leakage in the mercury fixed-point cell has been found.

  2. Magnetic Nanoparticle Thermometer: An Investigation of Minimum Error Transmission Path and AC Bias Error

    Directory of Open Access Journals (Sweden)

    Zhongzhou Du

    2015-04-01

    Full Text Available The signal transmission module of a magnetic nanoparticle thermometer (MNPT was established in this study to analyze the error sources introduced during the signal flow in the hardware system. The underlying error sources that significantly affected the precision of the MNPT were determined through mathematical modeling and simulation. A transfer module path with the minimum error in the hardware system was then proposed through the analysis of the variations of the system error caused by the significant error sources when the signal flew through the signal transmission module. In addition, a system parameter, named the signal-to-AC bias ratio (i.e., the ratio between the signal and AC bias, was identified as a direct determinant of the precision of the measured temperature. The temperature error was below 0.1 K when the signal-to-AC bias ratio was higher than 80 dB, and other system errors were not considered. The temperature error was below 0.1 K in the experiments with a commercial magnetic fluid (Sample SOR-10, Ocean Nanotechnology, Springdale, AR, USA when the hardware system of the MNPT was designed with the aforementioned method.

  3. The Distress Thermometer and its validity: a first psychometric study in Indonesian women with breast cancer.

    Directory of Open Access Journals (Sweden)

    Aulia Iskandarsyah

    Full Text Available PURPOSE: This study aims to translate the Distress Thermometer (DT into Indonesian, test its validity in Indonesian women with breast cancer and determine norm scores of the Indonesian DT for clinically relevant distress. METHODS: First, the original version of the DT was translated using a forward and backward translation procedure according to the guidelines. Next, a group of 120 breast cancer patients who were treated at the Outpatient Surgical Oncology Clinic in Hasan Sadikin Hospital in Indonesia completed a standard socio-demographic form, the DT and the Problem List, the Hospital Anxiety and Depression Scale (HADS and the WHO Quality of Life (WHOQOL-BREF. RESULTS: Receiver operating characteristic (ROC curve analyses identified an area under the curve = 0.81 when compared to the HADS cutoff score of 15. A cutoff score of 5 on the DT had the best sensitivity (0.81 and specificity (0.64. Patients who scored above this cutoff reported more problems in the practical, family, emotional, spiritual/religious and physical domains (30 out of 36 problems, p-value<0.05 than patients below the cutoff score. Patients at advanced stages of cancer experienced more emotional and physical problems. Patient's distress level was negatively correlated with overall quality of life, general health and all quality of life domains. CONCLUSIONS: The DT was found to be a valid tool for screening distress in Indonesian breast cancer patients. We recommend using a cutoff score of 5 in this population.

  4. A 6-bit 4 GS/s pseudo-thermometer segmented CMOS DAC

    Science.gov (United States)

    Yijun, Song; Wenyuan, Li

    2014-06-01

    A 6-bit 4 GS/s, high-speed and power-efficient DAC for ultra-high-speed transceivers in 60 GHz band millimeter wave technology is presented. A novel pseudo-thermometer architecture is proposed to realize a good compromise between the fast conversion speed and the chip area. Symmetrical and compact floor planning and layout techniques including tree-like routing, cross-quading and common-centroid method are adopted to guarantee the chip is fully functional up to near-Nyquist frequency in a standard 0.18 μm CMOS process. Post simulation results corroborate the feasibility of the designed DAC, which canperform good static and dynamic linearity without calibration. DNL errors and INL errors can be controlled within ±0.28 LSB and ±0.26 LSB, respectively. SFDR at 4 GHz clock frequency for a 1.9 GHz near-Nyquist sinusoidal output signal is 40.83 dB and the power dissipation is less than 37 mW.

  5. A 6-bit 4 GS/s pseudo-thermometer segmented CMOS DAC

    International Nuclear Information System (INIS)

    Song Yijun; Li Wenyuan

    2014-01-01

    A 6-bit 4 GS/s, high-speed and power-efficient DAC for ultra-high-speed transceivers in 60 GHz band millimeter wave technology is presented. A novel pseudo-thermometer architecture is proposed to realize a good compromise between the fast conversion speed and the chip area. Symmetrical and compact floor planning and layout techniques including tree-like routing, cross-quading and common-centroid method are adopted to guarantee the chip is fully functional up to near-Nyquist frequency in a standard 0.18 μm CMOS process. Post simulation results corroborate the feasibility of the designed DAC, which canperform good static and dynamic linearity without calibration. DNL errors and INL errors can be controlled within ±0.28 LSB and ±0.26 LSB, respectively. SFDR at 4 GHz clock frequency for a 1.9 GHz near-Nyquist sinusoidal output signal is 40.83 dB and the power dissipation is less than 37 mW. (semiconductor integrated circuits)

  6. Design of a temperature measurement and feedback control system based on an improved magnetic nanoparticle thermometer

    Science.gov (United States)

    Du, Zhongzhou; Sun, Yi; Liu, Jie; Su, Rijian; Yang, Ming; Li, Nana; Gan, Yong; Ye, Na

    2018-04-01

    Magnetic fluid hyperthermia, as a novel cancer treatment, requires precise temperature control at 315 K-319 K (42 °C-46 °C). However, the traditional temperature measurement method cannot obtain the real-time temperature in vivo, resulting in a lack of temperature feedback during the heating process. In this study, the feasibility of temperature measurement and feedback control using magnetic nanoparticles is proposed and demonstrated. This technique could be applied in hyperthermia. Specifically, the triangular-wave temperature measurement method is improved by reconstructing the original magnetization response of magnetic nanoparticles based on a digital phase-sensitive detection algorithm. The standard deviation of the temperature in the magnetic nanoparticle thermometer is about 0.1256 K. In experiments, the temperature fluctuation of the temperature measurement and feedback control system using magnetic nanoparticles is less than 0.5 K at the expected temperature of 315 K. This shows the feasibility of the temperature measurement method for temperature control. The method provides a new solution for temperature measurement and feedback control in hyperthermia.

  7. Assessment of a Technique for Estimating Total Column Water Vapor Using Measurements of the Infrared Sky Temperature

    Science.gov (United States)

    Merceret, Francis J.; Huddleston, Lisa L.

    2014-01-01

    A method for estimating the integrated precipitable water (IPW) content of the atmosphere using measurements of indicated infrared zenith sky temperature was validated over east-central Florida. The method uses inexpensive, commercial off the shelf, hand-held infrared thermometers (IRT). Two such IRTs were obtained from a commercial vendor, calibrated against several laboratory reference sources at KSC, and used to make IR zenith sky temperature measurements in the vicinity of KSC and Cape Canaveral Air Force Station (CCAFS). The calibration and comparison data showed that these inexpensive IRTs provided reliable, stable IR temperature measurements that were well correlated with the NOAA IPW observations.

  8. Medical applications of infrared thermography: A review

    Science.gov (United States)

    Lahiri, B. B.; Bagavathiappan, S.; Jayakumar, T.; Philip, John

    2012-07-01

    Abnormal body temperature is a natural indicator of illness. Infrared thermography (IRT) is a fast, passive, non-contact and non-invasive alternative to conventional clinical thermometers for monitoring body temperature. Besides, IRT can also map body surface temperature remotely. Last five decades witnessed a steady increase in the utility of thermal imaging cameras to obtain correlations between the thermal physiology and skin temperature. IRT has been successfully used in diagnosis of breast cancer, diabetes neuropathy and peripheral vascular disorders. It has also been used to detect problems associated with gynecology, kidney transplantation, dermatology, heart, neonatal physiology, fever screening and brain imaging. With the advent of modern infrared cameras, data acquisition and processing techniques, it is now possible to have real time high resolution thermographic images, which is likely to surge further research in this field. The present efforts are focused on automatic analysis of temperature distribution of regions of interest and their statistical analysis for detection of abnormalities. This critical review focuses on advances in the area of medical IRT. The basics of IRT, essential theoretical background, the procedures adopted for various measurements and applications of IRT in various medical fields are discussed in this review. Besides background information is provided for beginners for better understanding of the subject.

  9. Application of radcal gamma thermometer assemblies for coolant monitoring in Ringhals W-PWRs

    International Nuclear Information System (INIS)

    Smith, R.D.; Romslo, K.; Moen, Oe.

    1982-07-01

    A study has been carried out investigating how Radcal Gamma Thermometers (RGTs) can be used for coolant inventory and core cooling monitoring in the Ringhals Westinghouse PWRs. The study concludes that two types of RGT rods would be required to come up with a complete solution covering both coolant inventory and core cooling monitoring. Above-core RGT rods will be installed in the guide tubes housing the outlet thermocouples. The Above-Core RGT rod is designed with 8 sensors where 4 are located in the upper head and 4 in the plenum. This rod will give an early warning about loss of coolant or void formation in the space from top of fuel to the reactor lid. A ninth thermocouple in this rod will measure the core outlet temperature as did the thermocouple the RGT rod replaced. The Above-Core RGT rods will give an early warning about approach to Inadequate Core Cooling (ICC) by measuring the collapsed water level inside the thermocouple guide tube. Four such rods are recommended per reactor. In-Core RGT rods are inserted from the seal table. These rods will give the information required for intelligent accident management in case ICC has developed. The signals obtainable from the rods will give direct information about fuel decay heat, core heat transfer conditions, core temperature and core coolant water level. The In-Core RGT rods can be used for local power monitoring during normal operation. Such a system can be shown to be economically motivated from a reactor operation point of view due to increased sensor lifetime, more accurate local power measurements, simpler physics corrections to signals, lower exposure to maintenance personnel. The signal transmission to the control room has been discussed, and ways have been indicated for presenting the information available to the operators. (Authors)

  10. Accuracy of the Distress Thermometer for home care patients with palliative care needs in Germany.

    Science.gov (United States)

    Wüller, Johannes; Küttner, Stefanie; Foldenauer, Ann Christina; Rolke, Roman; Pastrana, Tania

    2017-06-01

    Our aim was to examine the accuracy of the German version of the Distress Thermometer (DT) compared with the Hospital Anxiety and Depression Scale (HADS) in patients with palliative care needs living at home. Ours was a 15-month cross-sectional study beginning in September of 2013 in Germany with consecutive patients cared for by a palliative home care service. The survey was implemented during the initial visit by a home care team. Patients were excluded if they were under 18 years of age, mentally or physically unable to complete the assessment questionnaires as judged by their healthcare worker, or unable to understand the German language. During the first encounter, the DT and HADS were applied, and sociodemographic and medical data were collected. A total of 89 persons completed both the HADS and DT questionnaires (response rate = 59.7%; mean age = 67 years; female = 55.1%; married = 65.2%; living home with relatives = 73.0%; oncological condition = 92.1%; Karnofsky Performance Scale [KPS] score: 0-40 = 30.3%, 50-70 = 57.3%, >80 = 6.7%). The mean DT score was 6.3 (±2.3), with 84.3% of participants scoring above the DT cutoff (≥4). The mean HADStotal score was 17.9 (±7.8), where 64% of participants had a total HADS score (HADStotal) ≥15, 51.7% reported anxiety (HADSanxiety ≥ 8), and 73% reported depression (HADSdepression ≥ 8). Using the HADS as a gold standard, a DT cutoff score ≥5 was optimal for identifying severe distress in patients with palliative care needs, with a sensitivity of 93.0%, a specificity of 34.4%, a positive predictive value (PPV) of 73.3%, and likelihood ratios LR+ = 1.42 (home with palliative care needs in order to offer adequate support.

  11. The Distress Thermometer assessed in women at risk of developing hereditary breast cancer.

    Science.gov (United States)

    van Dooren, S; Duivenvoorden, H J; Passchier, J; Bannink, M; Tan, M B M; Oldenmenger, W H; Seynaeve, C; van der Rijt, C C D

    2009-10-01

    The Distress Thermometer (DT) is a promising instrument to get insight into distress experienced by cancer patients. At our Family Cancer Clinic the DT, including an adapted problem list, was completed by 100 women at increased risk of developing hereditary breast cancer (mean age 45.2 years; SD: 10.5). Additionally, the women filled in either the Hospital Anxiety and Depression Scale as psychological component (n=48) or the somatic subscale of the Symptom Checklist-90 as somatic component (n=50) to identify associations with the DT-score. Further, the women filled in an evaluation form. The median score on the DT was 2 (range: 0-9). With regression analysis adjusted for age, the contribution of mood and somatic complaints, respectively, was investigated. The standardized regression coefficient for anxiety was 0.32 (ns), for depression 0.14 (ns) and for the somatic subscale 0.49 (pdepression was 16%, and for somatic complaints 24%. The differences between the coefficients were not significant. Evaluation forms were returned by 73 women. In 50% of the cases, the physician had discussed the DT/problem list, which was appreciated by the majority of these women (80%). Sixty-two percent of the women would recommend the use of the DT for other patients. The use of the DT/problem list seems promising for the current population, and was appreciated by the majority of the women. As mood and somatic complaints did not differ significantly in explaining the experienced distress, other candidate factors need to be examined.

  12. Thermal limits validation of gamma thermometer power adaption in CFE Laguna Verde 2 reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G.; Banfield, J. [GE-Hitachi Nuclear Energy Americas LLC, Global Nuclear Fuel, Americas LLC, 3901 Castle Hayne Road, Wilmingtonm, North Carolina (United States); Avila N, A., E-mail: Gabriel.Cuevas-Vivas@ge.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2016-09-15

    This paper presents the status of GEH work on Gamma Thermometer (GT) validation using the signals of the instruments installed in the Laguna Verde Unit 2 reactor core. The long-standing technical collaboration between Comision Federal de Electricidad (CFE), Global Nuclear Fuel - Americas LLC (GNF) and GE-Hitachi Nuclear Energy Americas LLC (GEH) is moving forward with solid steps to a final implementation of GTs in a nuclear reactor core. Each GT is integrated into a slightly modified Local Power Range Monitor (LPRM) assembly. Six instrumentation strings are equipped with two gamma field detectors for a total of twenty-four bundles whose calculated powers are adapted to the instrumentation readings in addition to their use as calibration instruments for LPRMs. Since November 2007, the six GT instrumentation strings have been operable with almost no degradation by the strong neutron and gamma fluxes in the Laguna Verde Unit 2 reactor core. In this paper, the thermal limits, Critical Power Ratio (CPR) and maximum Linear Heat Generation Rate (LHGR), of bundles directly monitored by either Traverse In-core Probes (TIPs) or GTs are used to establish validation results that confirm the viability of TIP system replacement with automatic fixed in-core probes (AFIPs, GTs, in a Boiling Water Reactor. The new GNF steady-state reactor core simulator AETNA02 is used to obtain power and exposure distribution. Using this code with an updated methodology for GT power adaption, a reduced value of the GT interpolation uncertainty is obtained that is fed into the LHGR calculation. This new method achieves margin recovery for the adapted thermal limits for use in the Economic Simplified Boiling Water Reactor (ESBWR) or any other BWR in the future that employs a GT based AFIP system for local power measurements. (Author)

  13. The workings of a molecular thermometer: the vibrational excitation of carbon tetrachloride by a solvent.

    Science.gov (United States)

    Graham, Polly B; Matus, Kira J M; Stratt, Richard M

    2004-09-15

    An intriguing energy-transfer experiment was recently carried out in methanol/carbon tetrachloride solutions. It turned out to be possible to watch vibrational energy accumulating in three of carbon tetrachloride's modes following initial excitation of O-H and C-H stretches in methanol, in effect making those CCl(4) modes "molecular thermometers" reporting on methanol's relaxation. In this paper, we use the example of a CCl(4) molecule dissolved in liquid argon to examine, on a microscopic level, just how this kind of thermal activation occurs in liquid solutions. The fact that even the lowest CCl(4) mode has a relatively high frequency compared to the intermolecular vibrational band of the solvent means that the only solute-solvent dynamics relevant to the vibrational energy transfer will be extraordinarily local, so much so that it is only the force between the instantaneously most prominent Cl and solvent atoms that will significantly contribute to the vibrational friction. We use this observation, within the context of a classical instantaneous-pair Landau-Teller calculation, to show that energy flows into CCl(4) primarily via one component of the nominally degenerate, lowest frequency, E mode and does so fast enough to make CCl(4) an excellent choice for monitoring methanol relaxation. Remarkably, within this theory, the different symmetries and appearances of the different CCl(4) modes have little bearing on how well they take up energy from their surroundings--it is only how high their vibrational frequencies are relative to the solvent intermolecular vibrational band edge that substantially favors one mode over another.

  14. Thermal limits validation of gamma thermometer power adaption in CFE Laguna Verde 2 reactor core

    International Nuclear Information System (INIS)

    Cuevas V, G.; Banfield, J.; Avila N, A.

    2016-09-01

    This paper presents the status of GEH work on Gamma Thermometer (GT) validation using the signals of the instruments installed in the Laguna Verde Unit 2 reactor core. The long-standing technical collaboration between Comision Federal de Electricidad (CFE), Global Nuclear Fuel - Americas LLC (GNF) and GE-Hitachi Nuclear Energy Americas LLC (GEH) is moving forward with solid steps to a final implementation of GTs in a nuclear reactor core. Each GT is integrated into a slightly modified Local Power Range Monitor (LPRM) assembly. Six instrumentation strings are equipped with two gamma field detectors for a total of twenty-four bundles whose calculated powers are adapted to the instrumentation readings in addition to their use as calibration instruments for LPRMs. Since November 2007, the six GT instrumentation strings have been operable with almost no degradation by the strong neutron and gamma fluxes in the Laguna Verde Unit 2 reactor core. In this paper, the thermal limits, Critical Power Ratio (CPR) and maximum Linear Heat Generation Rate (LHGR), of bundles directly monitored by either Traverse In-core Probes (TIPs) or GTs are used to establish validation results that confirm the viability of TIP system replacement with automatic fixed in-core probes (AFIPs, GTs, in a Boiling Water Reactor. The new GNF steady-state reactor core simulator AETNA02 is used to obtain power and exposure distribution. Using this code with an updated methodology for GT power adaption, a reduced value of the GT interpolation uncertainty is obtained that is fed into the LHGR calculation. This new method achieves margin recovery for the adapted thermal limits for use in the Economic Simplified Boiling Water Reactor (ESBWR) or any other BWR in the future that employs a GT based AFIP system for local power measurements. (Author)

  15. Infrared Heaters

    Science.gov (United States)

    1979-01-01

    The heating units shown in the accompanying photos are Panelbloc infrared heaters, energy savers which burn little fuel in relation to their effective heat output. Produced by Bettcher Manufacturing Corporation, Cleveland, Ohio, Panelblocs are applicable to industrial or other facilities which have ceilings more than 12 feet high, such as those pictured: at left the Bare Hills Tennis Club, Baltimore, Maryland and at right, CVA Lincoln- Mercury, Gaithersburg, Maryland. The heaters are mounted high above the floor and they radiate infrared energy downward. Panelblocs do not waste energy by warming the surrounding air. Instead, they beam invisible heat rays directly to objects which absorb the radiation- people, floors, machinery and other plant equipment. All these objects in turn re-radiate the energy to the air. A key element in the Panelbloc design is a coating applied to the aluminized steel outer surface of the heater. This coating must be corrosion resistant at high temperatures and it must have high "emissivity"-the ability of a surface to emit radiant energy. The Bettcher company formerly used a porcelain coating, but it caused a production problem. Bettcher did not have the capability to apply the material in its own plant, so the heaters had to be shipped out of state for porcelainizing, which entailed extra cost. Bettcher sought a coating which could meet the specifications yet be applied in its own facilities. The company asked The Knowledge Availability Systems Center, Pittsburgh, Pennsylvania, a NASA Industrial Applications Center (IAC), for a search of NASA's files

  16. A Field Assessment of a Prototype Meter for Measuring the Wet-Bulb Globe-Thermometer Index

    Science.gov (United States)

    Walters, J. D.

    1968-01-01

    A prototype electronic instrument for the direct measurement of the wet-bulb globe-thermometer index is described. An assessment is made of its accuracy, as compared with W.B.G.T. indices calculated from conventional thermometric data, and a comparison is made between W.B.G.T. values read from the meter and effective or corrected effective temperatures derived from separate thermometric and air velocity recording instruments in the same climates. The instrument proved to be reliable and accurate over a wide range of climates and is a useful self-contained device for use in habitability surveys and similar investigations. Images PMID:5663429

  17. Application of Monte Carlo Method for Evaluation of Uncertainties of ITS-90 by Standard Platinum Resistance Thermometer

    Science.gov (United States)

    Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin

    2017-06-01

    Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.

  18. Fabrication of a mini multi-fixed-point cell for the calibration of industrial platinum resistance thermometers

    Science.gov (United States)

    Ragay-Enot, Monalisa; Lee, Young Hee; Kim, Yong-Gyoo

    2017-07-01

    A mini multi-fixed-point cell (length 118 mm, diameter 33 mm) containing three materials (In-Zn eutectic (mass fraction 3.8% Zn), Sn and Pb) in a single crucible was designed and fabricated for the easy and economical fixed-point calibration of industrial platinum resistance thermometers (IPRTs) for use in industrial temperature measurements. The melting and freezing behaviors of the metals were investigated and the phase transition temperatures were determined using a commercial dry-block calibrator. Results showed that the melting plateaus are generally easy to realize and are reproducible, flatter and of longer duration. On the other hand, the freezing process is generally difficult, especially for Sn, due to the high supercooling required to initiate freezing. The observed melting temperatures at optimum set conditions were 143.11 °C (In-Zn), 231.70 °C (Sn) and 327.15 °C (Pb) with expanded uncertainties (k  = 2) of 0.12 °C, 0.10 °C and 0.13 °C, respectively. This multi-fixed-point cell can be treated as a sole reference temperature-generating system. Based on the results, the realization of melting points of the mini multi-fixed-point cell can be recommended for the direct calibration of IPRTs in industrial applications without the need for a reference thermometer.

  19. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    Energy Technology Data Exchange (ETDEWEB)

    Keawprasert, T. [National Institute of Metrology Thailand, Pathum thani (Thailand); Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S. [Physikalisch Technische Bundesanstalt, Braunschweig and Berlin (Germany)

    2013-09-11

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

  20. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    International Nuclear Information System (INIS)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S.

    2013-01-01

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody

  1. Thermometer by optical fiber for ampacity studies in overhead transmission lines; Termometro a fibra optica para estudo da ampacidade em linhas de transmissao aereas

    Energy Technology Data Exchange (ETDEWEB)

    Valente, L.C.G.; Kawase, L.R.; Silva Filho, J.I. da; Silva, J.M.M. da [Centro de Pesquisas de Energia Eletrica, Rio de Janeiro, RJ (Brazil); Igarashi, A.Y. [Universidade Federal, Rio de Janeiro, RJ (Brazil)

    1995-12-31

    This article suggests the utilization of thermometers constructed from optical fibers technology in overhead power transmission lines. This will help the studies in progress about the electric power systems ampacity. It also presents the advantages of using optical fibers instead of conventional thermometers. As an example, the fact that the optical fibers are dielectric and make possible the remote monitoring. It is also shown a possibility of introducing such measuring system in electric junctions where OPGW cables are used 4 refs., 4 figs.; e-mail: liliana at fis.puc-rio.br

  2. Long wavelength infrared radiation thermometry for non-contact temperature measurements in gas turbines

    Science.gov (United States)

    Manara, J.; Zipf, M.; Stark, T.; Arduini, M.; Ebert, H.-P.; Tutschke, A.; Hallam, A.; Hanspal, J.; Langley, M.; Hodge, D.; Hartmann, J.

    2017-01-01

    The objective of the EU project "Sensors Towards Advanced Monitoring and Control of Gas Turbine Engines (acronym STARGATE)" is the development of a suite of advanced sensors, instrumentation and related systems in order to contribute to the developing of the next generation of green and efficient gas turbine engines. One work package of the project deals with the design and development of a long wavelength infrared (LWIR) radiation thermometer for the non-contact measurement of the surface temperature of thermal barrier coatings (TBCs) during the operation of gas turbine engines. For opaque surfaces (e.g. metals or superalloys) radiation thermometers which are sensitive in the near or short wavelength infrared are used as state-of-the-art method for non-contact temperature measurements. But this is not suitable for oxide ceramic based TBCs (e.g. partially yttria stabilized zirconia) as oxide ceramics are semi-transparent in the near and short wavelength infrared spectral region. Fortunately the applied ceramic materials are non-transparent in the long wavelength infrared and additionally exhibit a high emittance in this wavelength region. Therefore, a LWIR pyrometer can be used for non-contact temperature measurements of the surfaces of TBCs as such pyrometers overcome the described limitation of existing techniques. For performing non-contact temperature measurements in gas turbines one has to know the infrared-optical properties of the applied TBCs as well as of the hot combustion gas in order to properly analyse the measurement data. For reaching a low uncertainty on the one hand the emittance of the TBC should be high (>0.9) in order to reduce reflections from the hot surrounding and on the other hand the absorbance of the hot combustion gas should be low (<0.1) in order to decrease the influence of the gas on the measured signal. This paper presents the results of the work performed by the authors with focus on the implementation of the LWIR pyrometer and the

  3. A new garnet-orthopyroxene thermometer developed: method, results and applications

    Science.gov (United States)

    Olivotos, Spyros-Christos; Kostopoulos, Dimitrios

    2014-05-01

    The Fe-Mg exchange reaction between garnet and orthopyroxene is a robust geothermometer that has extensively been used to retrieve metamorphic temperatures from granulitic and peridotitic/pyroxenitic lithologies with important implications on the thermal state of the continental lithosphere. More than 800 experimental mineral pairs from both simple and complex systems were gleaned from the literature covering the P-T range 0.5-15 GPa / 800-1800°C. Grt was treated as a senary (Py, Alm, Grs, Sps, Kno and Uv), whereas Opx as a septenary (En, Fs, Di, Hd, FeTs, MgTs and MgCrTs) solid solution. For Opx, Al in the M1 site was calculated following Carswell (1991) and Fe/Mg equipartitioning between sites was assumed. A mixing on sites model was employed to calculate mole fractions of components for both minerals. With regard to the excess free energy of solution and activity coefficients the formalism of Mukhopadhyay et al. (1993) was adopted treating both minerals as symmetric regular solutions. Calibration was achieved in multiple steps; in each step ΔS was allowed to vary until the standard deviation of the differences between experimental and calculated temperature for all experiments was minimised. The experiment with the largest absolute relative deviation in temperature was then eliminated and the process was repeated. The new thermometer reproduces the experimental data to within 50°C and is independent of P-T-X variations within the bounds of the calibrant data set. Application of our new calibration to metamorphosed crustal and mantle rocks that occur both as massifs and xenoliths in volcanics suggested the following results. Granulite terranes have recorded differences in temperature between peak and re-equilibration conditions in the range 100-340°C, primarily depending on the mechanism and rate of exhumation. Several provinces retain memory of discrete cooling pulses (e.g. Palni Hills, South Harris, Adirondacks, E. Antarctic Belt, Aldan Shield) whereas

  4. Performance Considerations for the SIMPL Single Photon, Polarimetric, Two-Color Laser Altimeter as Applied to Measurements of Forest Canopy Structure and Composition

    Science.gov (United States)

    Dabney, Philip W.; Harding, David J.; Valett, Susan R.; Vasilyev, Aleksey A.; Yu, Anthony W.

    2012-01-01

    The Slope Imaging Multi-polarization Photon-counting Lidar (SIMPL) is a multi-beam, micropulse airborne laser altimeter that acquires active and passive polarimetric optical remote sensing measurements at visible and near-infrared wavelengths. SIMPL was developed to demonstrate advanced measurement approaches of potential benefit for improved, more efficient spaceflight laser altimeter missions. SIMPL data have been acquired for wide diversity of forest types in the summers of 2010 and 2011 in order to assess the potential of its novel capabilities for characterization of vegetation structure and composition. On each of its four beams SIMPL provides highly-resolved measurements of forest canopy structure by detecting single-photons with 15 cm ranging precision using a narrow-beam system operating at a laser repetition rate of 11 kHz. Associated with that ranging data SIMPL provides eight amplitude parameters per beam unlike the single amplitude provided by typical laser altimeters. Those eight parameters are received energy that is parallel and perpendicular to that of the plane-polarized transmit pulse at 532 nm (green) and 1064 nm (near IR), for both the active laser backscatter retro-reflectance and the passive solar bi-directional reflectance. This poster presentation will cover the instrument architecture and highlight the performance of the SIMPL instrument with examples taken from measurements for several sites with distinct canopy structures and compositions. Specific performance areas such as probability of detection, after pulsing, and dead time, will be highlighted and addressed, along with examples of their impact on the measurements and how they limit the ability to accurately model and recover the canopy properties. To assess the sensitivity of SIMPL's measurements to canopy properties an instrument model has been implemented in the FLIGHT radiative transfer code, based on Monte Carlo simulation of photon transport. SIMPL data collected in 2010 over

  5. La détection infrarouge avec les plans focaux non refroidis : état de l'artUncooled focal plane infrared detectors: the state of the art

    Science.gov (United States)

    Tissot, Jean-Luc

    2003-12-01

    The emergence of uncooled detectors has opened new opportunities for IR detection for both military and commercial applications. Development of such devices involves a lot of trade-offs between the different parameters that define the technological stack. These trade-offs explain the number of different architectures that are under worldwide development. The key factor is to find a high sensitivity and low noise thermometer material compatible with silicon technology in order to achieve high thermal isolation in the smallest area as possible. Ferroelectric thermometer based hybrid technology and electrical resistive thermometer based (microbolometer) technology are under development. LETI and ULIS have chosen from the very beginning to develop first a monolithic microbolometer technology fully compatible with commercially available CMOS technology and secondly amorphous silicon based thermometer. This silicon approach has the greatest potential for reducing infrared detector manufacturing cost. After the development of the technology, the transfer to industrial facilities has been performed in a short period of time and the production is now ramping up with ULIS team in new facilities. LETI and ULIS are now working to facilitate the IRFPA integration into equipment in order to address a very large market. Achievement of this goal needs the development of smart sensors with on-chip advanced functions and the decrease of manufacturing cost of IRFPA by decreasing the pixel pitch and simplifying the vacuum package. We present in this paper the technology developed by CEA/LETI and its improvement for being able to designs 384×288 and 160×120 arrays with a pitch of 35 μm. Thermographic application needs high stability infrared detector with a precise determination of the amount of absorbed infrared flux. Hence, infrared detector with internal temperature stabilized shield has been developed and characterized. These results will be presented. To cite this article: J

  6. Dealing with the size-of-source effect in the calibration of direct-reading radiation thermometer

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, P. [Measurement Standards Laboratory of New Zealand, PO Box 31-310, Lower Hutt 5040 (New Zealand)

    2013-09-11

    The majority of general-purpose low-temperature handheld radiation thermometers are severely affected by the size-of-source effect (SSE). Calibration of these instruments is pointless unless the SSE is accounted for in the calibration process. Traditional SSE measurement techniques, however, are costly and time consuming, and because the instruments are direct-reading in temperature, traditional SSE results are not easily interpretable, particularly by the general user. This paper describes a simplified method for measuring the SSE, suitable for second-tier calibration laboratories and requiring no additional equipment, and proposes a means of reporting SSE results on a calibration certificate that should be easily understood by the non-specialist user.

  7. Infrared Astronomy Professional Development for K-12 Educators: WISE Telescope

    Science.gov (United States)

    Borders, Kareen; Mendez, B. M.

    2010-01-01

    K-12 educators need effective and relevant astronomy professional development. WISE Telescope (Wide-Field Infrared Survey Explorer) and Spitzer Space Telescope Education programs provided an immersive teacher professional development workshop at Arecibo Observatory in Puerto Rico during the summer of 2009. As many common misconceptions involve scale and distance, teachers worked with Moon/Earth scale, solar system scale, and distance of objects in the universe. Teachers built and used basic telescopes, learned about the history of telescopes, explored ground and satellite based telescopes, and explored and worked on models of WISE Telescope. An in-depth explanation of WISE and Spitzer telescopes gave participants background knowledge for infrared astronomy observations. We taught the electromagnetic spectrum through interactive stations. The stations included an overview via lecture and power point, the use of ultraviolet beads to determine ultraviolet exposure, the study of WISE lenticulars and diagramming of infrared data, listening to light by using speakers hooked up to photoreceptor cells, looking at visible light through diffraction glasses and diagramming the data, protocols for using astronomy based research in the classroom, and infrared thermometers to compare environmental conditions around the observatory. An overview of LIDAR physics was followed up by a simulated LIDAR mapping of the topography of Mars. We will outline specific steps for K-12 infrared astronomy professional development, provide data demonstrating the impact of the above professional development on educator understanding and classroom use, and detail future plans for additional K-12 professional development. Funding was provided by WISE Telescope, Spitzer Space Telescope, Starbucks, Arecibo Observatory, the American Institute of Aeronautics and Astronautics, and the Washington Space Grant Consortium.

  8. Stream temperature estimated in situ from thermal-infrared images: best estimate and uncertainty

    International Nuclear Information System (INIS)

    Iezzi, F; Todisco, M T

    2015-01-01

    The paper aims to show a technique to estimate in situ the stream temperature from thermal-infrared images deepening its best estimate and uncertainty. Stream temperature is an important indicator of water quality and nowadays its assessment is important particularly for thermal pollution monitoring in water bodies. Stream temperature changes are especially due to the anthropogenic heat input from urban wastewater and from water used as a coolant by power plants and industrial manufacturers. The stream temperatures assessment using ordinary techniques (e.g. appropriate thermometers) is limited by sparse sampling in space due to a spatial discretization necessarily punctual. Latest and most advanced techniques assess the stream temperature using thermal-infrared remote sensing based on thermal imagers placed usually on aircrafts or using satellite images. These techniques assess only the surface water temperature and they are suitable to detect the temperature of vast water bodies but do not allow a detailed and precise surface water temperature assessment in limited areas of the water body. The technique shown in this research is based on the assessment of thermal-infrared images obtained in situ via portable thermal imager. As in all thermographic techniques, also in this technique, it is possible to estimate only the surface water temperature. A stream with the presence of a discharge of urban wastewater is proposed as case study to validate the technique and to show its application limits. Since the technique analyzes limited areas in extension of the water body, it allows a detailed and precise assessment of the water temperature. In general, the punctual and average stream temperatures are respectively uncorrected and corrected. An appropriate statistical method that minimizes the errors in the average stream temperature is proposed. The correct measurement of this temperature through the assessment of thermal- infrared images obtained in situ via portable

  9. Feldspar, Infrared Stimulated Luminescence

    DEFF Research Database (Denmark)

    Jain, Mayank

    2014-01-01

    This entry primarily concerns the characteristics and the origins of infrared-stimulated luminescence in feldspars.......This entry primarily concerns the characteristics and the origins of infrared-stimulated luminescence in feldspars....

  10. A comparison between conductive and infrared devices for measuring mean skin temperature at rest, during exercise in the heat, and recovery.

    Science.gov (United States)

    Bach, Aaron J E; Stewart, Ian B; Disher, Alice E; Costello, Joseph T

    2015-01-01

    Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Mean skin temperature ([Formula: see text]) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). [Formula: see text] was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Bland-Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of [Formula: see text] found significant differences (p heat and recovery. These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring [Formula: see text] in the presence of, or following, metabolic and environmental induced heat stress.

  11. The behaviour of platelets in natural diamonds and the development of a new mantle thermometer

    Science.gov (United States)

    Speich, L.; Kohn, S. C.; Bulanova, G. P.; Smith, C. B.

    2018-05-01

    Platelets are one of the most common defects occurring in natural diamonds but their behaviour has not previously been well understood. Recent technical advances, and a much improved understanding of the correct interpretation of the main infrared (IR) feature associated with platelets (Speich et al. 2017), facilitated a systematic study of platelets in 40 natural diamonds. Three different types of platelet behaviour were identified here. Regular diamonds show linear correlations between both B-centre concentrations and platelet density and also between platelet size and platelet density. Irregular diamonds display reduced platelet density due to platelet breakdown, anomalously large or small platelets and a larger platelet size distribution. These features are indicative of high mantle storage temperatures. Finally, a previously unreported category of subregular diamonds is defined. These diamonds experienced low mantle residence temperatures and show smaller than expected platelets. Combining the systematic variation in platelet density with temperatures of mantle storage, determined by nitrogen aggregation, we can demonstrate that platelet degradation proceeds at a predictable rate. Thus, in platelet-bearing diamonds where N aggregation is complete, an estimate of annealing temperature can now be made for the first time.

  12. Infrared stereo calibration for unmanned ground vehicle navigation

    Science.gov (United States)

    Harguess, Josh; Strange, Shawn

    2014-06-01

    The problem of calibrating two color cameras as a stereo pair has been heavily researched and many off-the-shelf software packages, such as Robot Operating System and OpenCV, include calibration routines that work in most cases. However, the problem of calibrating two infrared (IR) cameras for the purposes of sensor fusion and point could generation is relatively new and many challenges exist. We present a comparison of color camera and IR camera stereo calibration using data from an unmanned ground vehicle. There are two main challenges in IR stereo calibration; the calibration board (material, design, etc.) and the accuracy of calibration pattern detection. We present our analysis of these challenges along with our IR stereo calibration methodology. Finally, we present our results both visually and analytically with computed reprojection errors.

  13. Extragalactic infrared astronomy

    International Nuclear Information System (INIS)

    Gondhalekar, P.M.

    1985-05-01

    The paper concerns the field of Extragalactic Infrared Astronomy, discussed at the Fourth RAL Workshop on Astronomy and Astrophysics. Fifteen papers were presented on infrared emission from extragalactic objects. Both ground-(and aircraft-) based and IRAS infrared data were reviewed. The topics covered star formation in galaxies, active galactic nuclei and cosmology. (U.K.)

  14. Temperature and other data were collected using thermometer and bottle casts in the Chukchi and Bering Sea from 1947-02-11 to 1949-07-26 (NODC Accession 9700081)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature, depth, oxygen, and salinity data were collected using thermometer and bottle casts from the USS CACOPAN, USS NEREUS, and HMCS CEDARWOOD in the Chukchi...

  15. Prevalence and related factors of psychological distress among cancer inpatients using routine Distress Thermometer and Chinese Health Questionnaire screening

    Directory of Open Access Journals (Sweden)

    Chiou YJ

    2016-10-01

    Full Text Available Yu-Jie Chiou,1 Nien-Mu Chiu,1 Liang-Jen Wang,2 Shau-Hsuan Li,3 Chun-Yi Lee,1 Ming-Kung Wu,1 Chien-Chih Chen,1 Yi-Shan Wu,1 Yu Lee1 1Department of Psychiatry, 2Department of Child and Adolescent Psychiatry, 3Department of Hematology-Oncology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China Background: Clinical practice guidelines suggest routine screening for distress among cancer patients for immediate early psychiatric care. However, previous studies focusing on routine screening for psychological distress among cancer inpatients in Taiwan are scant. Thus, the aim of this study was to evaluate the prevalence and related factors of psychological distress and mental illness among cancer inpatients in Taiwan. Patients and methods: This study was conducted as a retrospective chart review in a general hospital in southern Taiwan. Cancer inpatients were regularly screened by nursing staff using the Distress Thermometer and the 12-item Chinese Health Questionnaire. Positive screening results on either instrument were followed by a non-commanded referral to psychiatrists for clinical psychiatric diagnosis and treatment. Results: Of the 810 participants in this study, 179 (22.1% were recognized as having psychological distress. Younger age (odds ratio [OR] =1.82, having head and neck cancer (OR =2.43, and having not received chemotherapy (OR =1.58 were significantly related to psychological distress. Among the 56 patients (31.3% with psychological distress who were referred to psychiatrists, the most common mental illness was adjustment disorder (n=22, 39.2%, followed by major depressive disorder (n=13, 23.2%, depressive disorder not otherwise specified (n=6, 10.7%, and anxiety disorder not otherwise specified (n=4, 7.1%. Conclusion: Our study indicated that cancer inpatients with psychological distress were more likely to be younger in age, have head and neck cancer, and have not

  16. Parent-Child Agreement Using the Spence Children’s Anxiety Scale and a Thermometer in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    T. May

    2015-01-01

    Full Text Available Children with Autism Spectrum Disorder (ASD experience high anxiety which often prompts clinical referral and requires intervention. This study aimed to compare parent and child reports on the Spence Children’s Anxiety Scale (SCAS and a child-reported “worry thermometer” in 88 children aged 8–13 years, 44 with ASD and 44 age, gender, and perceptual IQ matched typically developing children. There were no gender differences in child report on the SCAS and worry thermometers. Results indicated generally good correlations between parent and child self-reported SCAS symptoms for typically developing children but poor agreement in parent-child ASD dyads. The worry thermometer child-report did not reflect child or parent reports on the SCAS. Findings suggest 8–13-year-old children with ASD may have difficulties accurately reporting their anxiety levels. The clinical implications were discussed.

  17. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  18. Two-color QCD via dimensional reduction

    Czech Academy of Sciences Publication Activity Database

    Zhang, T.; Brauner, Tomáš; Kurkela, A.; Vuorinen, A.

    2012-01-01

    Roč. 2012, č. 139 (2012), s. 1-16 ISSN 1126-6708 Institutional support: RVO:61389005 Keywords : thermal field theory * QCD * confinement Subject RIV: BE - Theoretical Physics Impact factor: 5.618, year: 2012

  19. Reviewing the Evidence Base for the Children and Young People Safety Thermometer (CYPST: A Mixed Studies Review

    Directory of Open Access Journals (Sweden)

    Lydia Aston

    2016-01-01

    Full Text Available The objective was to identify evidence to support use of specific harms for the development of a children and young people’s safety thermometer (CYPST. We searched PubMed, Web of Knowledge, and Cochrane Library post-1999 for studies in pediatric settings about pain, skin integrity, extravasation injury, and use of pediatric early warning scores (PEWS. Following screening, nine relevant articles were included. Convergent synthesis methods were used drawing on thematic analysis to combine findings from studies using a range of methods (qualitative, quantitative, and mixed methods. A review of PEWS was identified so other studies on this issue were excluded. No relevant studies about extravasation injury were identified. The synthesized results therefore focused on pain and skin integrity. Measurement and perception of pain were complex and not always carried out according to best practice. Skin abrasions were common and mostly associated with device related injuries. The findings demonstrate a need for further work on perceptions of pain and effective communication of concerns about pain between parents and nursing staff. Strategies for reducing device-related injuries warrant further research focusing on prevention. Together with the review of PEWS, these synthesized findings support the inclusion of pain, skin integrity, and PEWS in the CYPST.

  20. Fiber-optic thermometer application of thermal radiation from rare-earth end-doped SiO2 fiber

    International Nuclear Information System (INIS)

    Katsumata, Toru; Morita, Kentaro; Komuro, Shuji; Aizawa, Hiroaki

    2014-01-01

    Visible light thermal radiation from SiO 2 glass doped with Y, La, Ce, Pr, Nd, Eu, Tb, Dy, Ho, Er, Tm, Yb, and Lu were studied for the fiber-optic thermometer application based on the temperature dependence of thermal radiation. Thermal radiations according to Planck's law of radiation are observed from the SiO 2 fibers doped with Y, La, Ce, Pr, Eu, Tb, and Lu at the temperature above 1100 K. Thermal radiations due to f-f transitions of rare-earth ions are observed from the SiO 2 fibers doped with Nd, Dy, Ho, Er, Tm, and Yb at the temperature above 900 K. Peak intensities of thermal radiations from rare-earth doped SiO 2 fibers increase sensitively with temperature. Thermal activation energies of thermal radiations by f-f transitions seen in Nd, Dy, Ho, Er, Tm, and Yb doped SiO 2 fibers are smaller than those from SiO 2 fibers doped with Y, La, Ce, Pr, Eu, Tb, and Lu. Thermal radiation due to highly efficient f-f transitions in Nd, Dy, Ho, Er, Tm, and Yb ions emits more easily than usual thermal radiation process. Thermal radiations from rare-earth doped SiO 2 are potentially applicable for the fiber-optic thermometry above 900 K

  1. Patients' and clinicians' experiences of holistic needs assessment using a cancer distress thermometer and problem list: A qualitative study.

    Science.gov (United States)

    Biddle, Lucy; Paramasivan, Sangeetha; Harris, Susan; Campbell, Rona; Brennan, James; Hollingworth, William

    2016-08-01

    Psychosocial needs assessment is recommended for patients undergoing cancer treatment, but trials of effectiveness of assessment tools provide mixed results. This qualitative study aimed to understand how such tools are experienced by patients and clinicians in order to optimise use in the future. Qualitative interviews were used in a mixed-methods sequential design following a randomised controlled trial of needs assessment using the Distress Thermometer and Problem List (DT&PL), and explored patients' and clinicians' evaluations of the needs assessment process. Benefits of needs assessment using the DT&PL included the potential to detect hidden distress, allow opportunity for distress to be discussed, and to deliver outcomes to address problems. However, effectiveness and patient willingness to report all forms of distress could be hindered by: clinicians feeling ill-equipped to deal with 'non-physical' distress and patients questioning their appropriateness to do so; time constraints; insufficient support services and referral guidelines; inappropriate timing; and lack of follow-up. The benefits of a holistic needs assessment cannot be realised without matching time and frequency of administration to the dynamic nature of distress during cancer, and making changes to the context of delivery - for instance, providing protected time, increasing referral options and clinician training. Significant investment is needed to optimise potential benefits for patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Validation of malayalam version of national comprehensive cancer network distress thermometer and its feasibility in oncology patients

    Directory of Open Access Journals (Sweden)

    M S Biji

    2018-01-01

    Full Text Available Context: This study was designed to translate and validate the National Comprehensive Cancer Network (NCCN distress thermometer (DT in regional language " Malayalam" and to see the feasibility of using it in our patients. Aims: (1 To translate and validate the NCCN DT. (2 To study the feasibility of using validated Malayalam translated DT in Malabar Cancer center. Settings and Design: This is a single-arm prospective observational study. The study was conducted at author's institution between December 8, 2015, and January 20, 2016 in the Department of Cancer Palliative Medicine. Materials and Methods: This was a prospective observational study carried out in two phases. In Phase 1, the linguistic validation of the NCCN DT was done. In Phase 2, the feasibility, face validity, and utility of the translated of NCCN DT in accordance with QQ-10 too was done. Statistical Analysis Used: SPSS version 16 (SPSS Inc. Released 2007. SPSS for Windows, Version 16.0. Chicago, SPSS Inc. was used for analysis. Results: Ten patients were enrolled in Phase 2. The median age was 51.5 years and 40% of patients were male. All patients had completed at least basic education up to the primary level. The primary site of cancer was heterogeneous. The NCCN DT completion rate was 100%. The face validity, utility, reliability, and feasibility were 100%, 100%, 100%, and 90%, respectively. Conclusion: It can be concluded that the Malayalam validated DT has high face validity, utility, and it is feasible for its use.

  3. Validation of Malayalam Version of National Comprehensive Cancer Network Distress Thermometer and its Feasibility in Oncology Patients.

    Science.gov (United States)

    Biji, M S; Dessai, Sampada; Sindhu, N; Aravind, Sithara; Satheesan, B

    2018-01-01

    This study was designed to translate and validate the National Comprehensive Cancer Network (NCCN) distress thermometer (DT) in regional language " Malayalam" and to see the feasibility of using it in our patients. (1) To translate and validate the NCCN DT. (2) To study the feasibility of using validated Malayalam translated DT in Malabar Cancer center. This is a single-arm prospective observational study. The study was conducted at author's institution between December 8, 2015, and January 20, 2016 in the Department of Cancer Palliative Medicine. This was a prospective observational study carried out in two phases. In Phase 1, the linguistic validation of the NCCN DT was done. In Phase 2, the feasibility, face validity, and utility of the translated of NCCN DT in accordance with QQ-10 too was done. SPSS version 16 (SPSS Inc. Released 2007. SPSS for Windows, Version 16.0. Chicago, SPSS Inc.) was used for analysis. Ten patients were enrolled in Phase 2. The median age was 51.5 years and 40% of patients were male. All patients had completed at least basic education up to the primary level. The primary site of cancer was heterogeneous. The NCCN DT completion rate was 100%. The face validity, utility, reliability, and feasibility were 100%, 100%, 100%, and 90%, respectively. It can be concluded that the Malayalam validated DT has high face validity, utility, and it is feasible for its use.

  4. Use of the distress thermometer to evaluate symptoms, outcome and satisfaction in a specialist psycho-oncology service.

    Science.gov (United States)

    Blenkiron, Paul; Brooks, Alexander; Dearden, Richard; McVey, Joanne

    2014-01-01

    The National Institute for Health and Care Excellence recommends the use of structured tools to improve holistic care for patients with cancer. The Distress Thermometer and Problem Checklist (DT) is commonly used for screening in physical health settings. However, it has not been integrated into the clinical pathway within specialist psycho-oncology services. We used the DT to examine the broad clinical effectiveness of psycho-oncology intervention and to ascertain factors from the DT linked to an improved outcome. We also evaluated patients' satisfaction with their care. We asked 111 adult outpatients referred to York Psycho-Oncology Service to complete the DT at their first appointment. Individuals offered a period of psycho-oncology care re-rated their emotional distress, problems and service satisfaction on the DT at discharge. Median distress scores decreased significantly (from 6 to 4, Wilcoxon's z = -4.83, P psycho-oncology care. It may also provide evidence to support the effectiveness of specialist psycho-oncology interventions. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Final report on SIM.T-S2: Comparison of the calibration of 100 Ω platinum resistance thermometers

    Science.gov (United States)

    del Campo, D.; Chimenti Ruiz, V.; Méndez-Lango, E.; Córdova, L.; von Borries, E.; Sánchez, C. A.; Arévalo, A.; Aguilera, B.; Guillén, E.; Cabrera, C.; Quintana, L.

    2013-01-01

    An International Comparison on industrial platinum resistance thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Mexico and the Andean Countries (Bolivia, Colombia, Ecuador, Peru and Venezuela) began in 2004 and was successfully completed in 2005. Two PRTs were circulated (hand-carried) and compared from -40 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, was the pilot laboratory and the Centro Nacional de Metrología (Mexican NMI), CENAM, was the co-pilot laboratory. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber.

    Science.gov (United States)

    Lee, Bongsoo; Shin, Sang Hun; Jang, Kyoung Won; Yoo, Wook Jae

    2015-05-11

    In this study, we have studied the effects of temperature and X-ray energy variations on the light output signals from two different fiber-optic sensors, a fiber-optic dosimeter (FOD) based on a BCF-12 as a plastic scintillating fiber (PSF) and a fiber-optic thermometer (FOT) using a silver halide optical fiber as an infrared optical fiber (IR fiber). During X-ray beam irradiation, the scintillating light and IR signals were measured simultaneously using a dosimeter probe of the FOD and a thermometer probe of the FOT. The probes were placed in a beaker with water on the center of a hotplate, under variation of the tube potential of a digital radiography system or the temperature of the water in the beaker. From the experimental results, in the case of the PSF, the scintillator light output at the given tube potential decreased as the temperature increased in the temperature range from 25 to 60 °C. We demonstrated that commonly used BCF-12 has a significant temperature dependence of -0.263 ± 0.028%/°C in the clinical temperature range. Next, in the case of the IR fiber, the intensity of the IR signal was almost uniform at each temperature regardless of the tube potential range from 50 to 150 kVp. Therefore, we also demonstrated that the X-ray beam with an energy range used in diagnostic radiology does not affect the IR signals transmitted via a silver halide optical fiber.

  7. Infrared microscope inspection apparatus

    Science.gov (United States)

    Forman, Steven E.; Caunt, James W.

    1985-02-26

    Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface.

  8. Far infrared supplement: Catalog of infrared observations, second edition

    International Nuclear Information System (INIS)

    Gezari, D.Y.; Schmitz, M.; Mead, J.M.

    1988-08-01

    The Far Infrared Supplement: Catalog of Infrared Observations summarizes all infrared astronomical observations at far infrared wavelengths (5 to 1000 microns) published in the scientific literature from 1965 through 1986. The Supplement list contain 25 percent of the observations in the full Catalog of Infrared Observations (CIO), and essentially eliminates most visible stars from the listings. The Supplement is thus more compact than the main catalog, and is intended for easy reference during astronomical observations. The Far Infrared Supplement (2nd Edition) includes the Index of Infrared Source Positions and the Bibliography of Infrared Astronomy for the subset of far infrared observations listed

  9. Mid-Infrared Lasers

    Data.gov (United States)

    National Aeronautics and Space Administration — Mid infrared solid state lasers for Differential Absorption Lidar (DIAL) systems required for understanding atmospheric chemistry are not available. This program...

  10. Laboratory calibration of the calcium carbonate clumped isotope thermometer in the 25-250 °C temperature range

    Science.gov (United States)

    Kluge, Tobias; John, Cédric M.; Jourdan, Anne-Lise; Davis, Simon; Crawshaw, John

    2015-05-01

    Many fields of Earth sciences benefit from the knowledge of mineral formation temperatures. For example, carbonates are extensively used for reconstruction of the Earth's past climatic variations by determining ocean, lake, and soil paleotemperatures. Furthermore, diagenetic minerals and their formation or alteration temperature may provide information about the burial history of important geological units and can have practical applications, for instance, for reconstructing the geochemical and thermal histories of hydrocarbon reservoirs. Carbonate clumped isotope thermometry is a relatively new technique that can provide the formation temperature of carbonate minerals without requiring a priori knowledge of the isotopic composition of the initial solution. It is based on the temperature-dependent abundance of the rare 13C-18O bonds in carbonate minerals, specified as a Δ47 value. The clumped isotope thermometer has been calibrated experimentally from 1 °C to 70 °C. However, higher temperatures that are relevant to geological processes have so far not been directly calibrated in the laboratory. In order to close this calibration gap and to provide a robust basis for the application of clumped isotopes to high-temperature geological processes we precipitated CaCO3 (mainly calcite) in the laboratory between 23 and 250 °C. We used two different precipitation techniques: first, minerals were precipitated from a CaCO3 supersaturated solution at atmospheric pressure (23-91 °C), and, second, from a solution resulting from the mixing of CaCl2 and NaHCO3 in a pressurized reaction vessel at a pressure of up to 80 bar (25-250 °C).

  11. Screening young adult cancer survivors for distress with the Distress Thermometer: Comparisons with a structured clinical diagnostic interview.

    Science.gov (United States)

    Recklitis, Christopher J; Blackmon, Jaime E; Chang, Grace

    2016-01-15

    The validity of the Distress Thermometer (DT) as a screen for psychological distress in young adult cancer survivors was assessed by comparing it with the results of a psychiatric diagnostic interview, the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition (DSM-IV) (SCID), to evaluate the accuracy of the DT and identify optimal cutoff scores for this population. A total of 247 survivors aged 18 to 40 years completed the DT and SCID. Based on the SCID, participants were classified as having: 1) ≥ 1 SCID diagnoses; 2) significant symptoms, but no SCID diagnosis; or 3) no significant SCID symptoms. Receiver operating characteristic analyses determined the sensitivity and specificity of all possible DT cutoff scores for detecting survivors with a SCID diagnosis, and subsequently for survivors with significant SCID symptoms or a SCID diagnosis. The recommended DT cutoff score of ≥5 failed to identify 31.81% of survivors with a SCID diagnosis (sensitivity of 68.18% and specificity of 78.33%), and 32.81% of survivors with either significant SCID symptoms or a SCID diagnosis. No alternative DT cutoff score met the criteria for acceptable sensitivity (≥85%) and specificity (≥75%). The DT does not reliably identify young adult cancer survivors with psychiatric problems identified by a "gold standard" structured psychiatric interview. Therefore, the DT should not be used as a stand-alone psychological screen in this population. Cancer 2016;122:296-303. © 2015 American Cancer Society. © 2015 American Cancer Society.

  12. How Hot are Your Ions Really? A Threshold Collision-Induced Dissociation Study of Substituted Benzylpyridinium "Thermometer" Ions

    Science.gov (United States)

    Carpenter, John E.; McNary, Christopher P.; Furin, April; Sweeney, Andrew F.; Armentrout, P. B.

    2017-09-01

    The first absolute experimental bond dissociation energies (BDEs) for the main heterolytic bond cleavages of four benzylpyridinium "thermometer" ions are measured using threshold collision-induced dissociation in a guided ion beam tandem mass spectrometer. In this experiment, substituted benzylpyridinium ions are introduced into the apparatus using an electrospray ionization source, thermalized, and collided with Xe at varied kinetic energies to determine absolute cross-sections for these reactions. Various effects are accounted for, including kinetic shifts, multiple collisions, and internal and kinetic energy distributions. These experimentally measured 0 K BDEs are compared with computationally predicted values at the B3LYP-GD3BJ, M06-GD3, and MP2(full) levels of theory with a 6-311+G(2d,2p) basis set using vibrational frequencies and geometries determined at the B3LYP/6-311+G(d,p) level. Additional dissociation pathways are observed for nitrobenzylpyridinium experimentally and investigated using these same levels of theory. Experimental BDEs are also compared against values in the literature at the AM1, HF, B3LYP, B3P86, and CCSD(T) levels of theory. Of the calculated values obtained in this work, the MP2(full) level of theory with counterpoise corrections best reproduces the experimental results, as do the similar literature CCSD(T) values. Lastly, the survival yield method is used to determine the characteristic temperature (Tchar) of the electrospray source prior to the thermalization region and to confirm efficient thermalization. [Figure not available: see fulltext.

  13. Long-term comparison of temperature measurements by the multi-plate shield and Czech-Slovak thermometer screen

    Energy Technology Data Exchange (ETDEWEB)

    Mozny, Martin; Stepanek, Petr; Hajkova, Lenka; Bares, Daniel [Doksany Observatory, Doksany (Czech Republic). Czech Hydrometeorological Inst.; Trnka, Mirek [Academy of Science of the Czech Republic, Brno (Czech Republic). Global Change Research Centre; Zalud, Zdenek; Semeradova, Daniela [Mendel Univ., Brno (Czech Republic). Agrosystems and Bioclimatology; Koznarova, Vera [Czech Univ. of Life Sciences, Prague (Czech Republic). Dept. of Agroecology and Biometeorology

    2012-04-15

    Differences between measurements taken with the Czech-Slovak thermometer screen (TS) and the multiplate radiation shield (MRS) should not be neglected. The average difference between the TS and the MRS measurements varied between 0.3 and 2.8 C during suitable weather conditions (wind speed less than 3 m/s, bright and sunny day) throughout the year, during both daytime and nighttime hours. A 10-year time series of comparative measurements in Doksany, Czech Republic, showed that relative to TS, measurements from MRS yielded average and minimum air temperatures that were lower in the winter and higher in the summer. Daily maximum air temperatures were lower for MRS than TS throughout the year. The greatest differences were observed in the maximum air temperatures; only 62 % of all differences between the TS and MRS were less than 0.5 C, and 70 % were less than 1 C. Among minimum air temperatures, 60 % of differences were less than 0.5 C, and 79 % were less than 1 C. In contrast, 74 % of all differences in average daily temperature were less than 0.5 C, and 97 % were less than 1 C. The use of temperature measurements from multiple equipments may negatively affect inference from climate and hydro-meteorological models. Irregular temperature data could be corrected using a simulation of temperature differences (SITEDI) model, which incorporates differences between the MRS and the TS. It is important to consider whether temperature data in the Czech Republic and Slovakia come from the TS or the MRS when analyzing and modeling temperature in Central Europe. (orig.)

  14. THE CONTRIBUTION OF TP-AGB STARS TO THE MID-INFRARED COLORS OF NEARBY GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Chisari, Nora E. [Department of Astrophysical Sciences, Princeton University, 4 Ivy Lane, Princeton, NJ 08544 (United States); Kelson, Daniel D., E-mail: nchisari@astro.princeton.edu [Observatories of the Carnegie Institution of Science, 813 Santa Barbara St., Pasadena, CA 91101 (United States)

    2012-07-10

    We study the mid-infrared color space of 30 galaxies from the Spitzer Infrared Nearby Galaxies Survey (SINGS) survey for which Sloan Digital Sky Survey data are also available. We construct two-color maps for each galaxy and compare them to results obtained from combining Maraston evolutionary synthesis models, galactic thermally pulsating asymptotic giant branch (TP-AGB) colors, and smooth star formation histories. For most of the SINGS sample, the spatially extended mid-IR emission seen by Spitzer in normal galaxies is consistent with our simple model in which circumstellar dust from TP-AGB stars dominates at 8 and 24 {mu}m. There is a handful of exceptions that we identify as galaxies that have high star formation rates presumably with star formation histories that cannot be assumed to be smooth, or anemic galaxies, which were depleted of their H I at some point during their evolution and have very low ongoing star formation rates.

  15. THE CONTRIBUTION OF TP-AGB STARS TO THE MID-INFRARED COLORS OF NEARBY GALAXIES

    International Nuclear Information System (INIS)

    Chisari, Nora E.; Kelson, Daniel D.

    2012-01-01

    We study the mid-infrared color space of 30 galaxies from the Spitzer Infrared Nearby Galaxies Survey (SINGS) survey for which Sloan Digital Sky Survey data are also available. We construct two-color maps for each galaxy and compare them to results obtained from combining Maraston evolutionary synthesis models, galactic thermally pulsating asymptotic giant branch (TP-AGB) colors, and smooth star formation histories. For most of the SINGS sample, the spatially extended mid-IR emission seen by Spitzer in normal galaxies is consistent with our simple model in which circumstellar dust from TP-AGB stars dominates at 8 and 24 μm. There is a handful of exceptions that we identify as galaxies that have high star formation rates presumably with star formation histories that cannot be assumed to be smooth, or anemic galaxies, which were depleted of their H I at some point during their evolution and have very low ongoing star formation rates.

  16. On infrared divergences

    International Nuclear Information System (INIS)

    Parisi, G.

    1979-01-01

    The structure of infrared divergences is studied in superrenormalizable interactions. It is conjectured that there is an extension of the Bogoliubov-Parasiuk-Hepp theorem which copes also with infrared divergences. The consequences of this conjecture on the singularities of the Borel transform in a massless asymptotic free field theory are discussed. The application of these ideas to gauge theories is briefly discussed. (Auth.)

  17. Infrared thermometry: a remote sensing technique for predicting yield in water-stressed cotton

    International Nuclear Information System (INIS)

    Pinter, P.J.; Fry, K.E.; Guinn, G.; Mauney, J.R.

    1983-01-01

    A crop water stress index (CWSI) was derived from air temperatures, air vapor pressure deficits and the midday radiant leaf temperatures of cotton plants that were exposed to different early-season irrigation treatments at Phoenix, AZ, U.S.A. To calculate the CWSI, an infrared thermometer was used to measure leaf temperatures which were then scaled relative to minimum and maximum temperatures expected for no-stress (CWSI=0) and extreme drought-stress conditions (CWSI=1). Results showed the CWSI behaved as expected, dropping to low levels following an irrigation and increasing gradually as the cotton plants depleted soil moisture reserves. The final yield of seed cotton was significantly inversely correlated with the average CWSI observed over the interval from the appearance of the first square until two weeks following the final irrigation

  18. SHORT COMMUNICATION: Correlation between the Resistance Ratios of Platinum Resistance Thermometers at the Melting Point of Gallium and the Triple Point of Mercury

    Science.gov (United States)

    Singh, Y. P.; Maas, H.; Edler, F.; Zaidi, Z. H.

    1994-01-01

    A set of resistance ratios (W) for platinum resistance thermometers was obtained at the triple point of Hg and the melting point of Ga in order to study their relationship. It was found that using measured values for one of the fixed points, a linear equation will predict the value of the other. These measurements also indicate that the fixed points of Hg and of Ga are inconsistent by about 1,5 mK in the sense that either the melting point of Ga or the triple point of Hg was assigned too high a value on the ITS-90.

  19. Body surface infrared thermometry in patients with central venous cateter-related infections.

    Science.gov (United States)

    Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio

    2015-01-01

    To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.

  20. The reproducibility of some thermometric fixed points and the accuracy of temperature measurements using platinum resistance thermometers

    Energy Technology Data Exchange (ETDEWEB)

    Ancsin, J. [National Research Council of Canada, Ottawa, ON (Canada). Inst. for National Measurement Standards; Mendez-Lango, E. [Centro Nacional de Metrologia (CENAM), Div. Termometria, Queretaro (Mexico)

    1999-07-01

    The reproducibility of some thermometric fixed points and the accuracy of four platinum resistance thermometers (PRTs) were studied. It was found that the fixed points of aluminium (Al), zinc (Zn), tin (Sn), indium (In) and gallium (Ga) were realized reproducibly within {+-}0.17 mK; {+-}0.11 mK; {+-}0.10 mK; {+-}0.13 mK and {+-}0.12 mK, respectively. Because the actual impurities and their concentration in our samples (of 99.9999 % or 99.999 99 % purity) are unknown, the systematic uncertainly due to impurities cannot be estimated. However, any of the samples of Ga, In, Sn, Zn and Al is consistent with the rest within {+-}0.2 mK, using a cubic or quadratic deviation function, in the temperature range 0 deg C to 660 deg C. This indicates that the effect of impurities is negligible. Four PRTs were selected at random. They were calibrated repeatedly, first up to the Zn point and then up to the Al point. The resistance of each PRT drifted. From time to time, for each PRT, a seemingly well-established resistance drift suddenly and unpredictably changed to a different rate of drift. Occasionally, the resistance of the PRTs shifted. Such unpredictable changes obviously limit the accuracy of temperature measurements using PRTs no matter what the accuracy of their calibrations. In the case of our four PRTs, the uncertainty of temperature measurements near 660 deg C ranged from about {+-}1 mK to about {+-}2,5 mK even though they were all calibrated at all fixed points well within {+-}0.25 mK uncertainty. Possible explanations are offered for the apparently permanent drifts and the erratic shifts in the resistance of the PRTs. Some comments are made concerning the ambiguity of 'immersion tests' in general. The furnaces of the National Research Council of Canada used in this work are high-temperature adiabatic calorimeters. (authors)

  1. Infrared fibers for radiometer thermometry in hypothermia and hyperthermia treatment

    International Nuclear Information System (INIS)

    Katzir, A.; Bowman, H.F.; Asfour, Y.; Zur, A.; Valeri, C.R.

    1989-01-01

    Hypothermia is a condition which results from prolonged exposure to a cold environment. Rapid and efficient heating is needed to rewarm the patient from 32-35 degrees C to normal body temperature. Hyperthermia in cancer treatment involves heating malignant tumors to 42.5-43.0 degrees C for an extended period (e.g., 30 min) in an attempt to obtain remission. Microwave or radio frequency heating is often used for rewarming in hypothermia or for temperature elevation in hyperthermia treatment. One severe problem with such heating is the accurate measurement and control of temperature in the presence of a strong electromagnetic field. For this purpose, we have developed a fiberoptic radiometer system which is based on a nonmetallic, infrared fiber probe, which can operate either in contact or noncontact mode. In preliminary investigations, the radiometer worked well in a strong microwave or radiofrequency field, with an accuracy of +/- 0.5 degrees C. This fiberoptic thermometer was used to control the surface temperature of objects within +/- 2 degrees C

  2. Barrier Infrared Detector (BIRD)

    Data.gov (United States)

    National Aeronautics and Space Administration — A recent breakthrough in MWIR detector design, has resulted in a high operating temperature (HOT) barrier infrared detector (BIRD) that is capable of spectral...

  3. Infrared Sky Surveys

    Science.gov (United States)

    Price, Stephan D.

    2009-02-01

    A retrospective is given on infrared sky surveys from Thomas Edison’s proposal in the late 1870s to IRAS, the first sensitive mid- to far-infrared all-sky survey, and the mid-1990s experiments that filled in the IRAS deficiencies. The emerging technology for space-based surveys is highlighted, as is the prominent role the US Defense Department, particularly the Air Force, played in developing and applying detector and cryogenic sensor advances to early mid-infrared probe-rocket and satellite-based surveys. This technology was transitioned to the infrared astronomical community in relatively short order and was essential to the success of IRAS, COBE and ISO. Mention is made of several of the little known early observational programs that were superseded by more successful efforts.

  4. Infrared emission from protostars

    International Nuclear Information System (INIS)

    Adams, F.C.; Shu, F.H.

    1985-01-01

    The emergent spectral energy distribution at infrared to radio wavelengths is calculated for the simplest theoretical construct of a low-mass protostar. It is shown that the emergent spectrum in the infrared is insensitive to the details assumed for the temperature profile as long as allowance is made for a transition from optically thick to optically thin conditions and luminosity conservation isenforced at the inner and outer shells. The radiation in the far infrared and submillimeter wavelengths depends on the exact assumptions made for grain opacities at low frequencies. An atlas of emergent spectral energy distributions is presented for a grid of values of the instantaneous mass of the protostar and the mass infall rate. The attenuated contribution of the accretion shock to the near-infrared radiation is considered. 50 references

  5. Additive Manufacturing Infrared Inspection

    Science.gov (United States)

    Gaddy, Darrell; Nettles, Mindy

    2015-01-01

    The Additive Manufacturing Infrared Inspection Task started the development of a real-time dimensional inspection technique and digital quality record for the additive manufacturing process using infrared camera imaging and processing techniques. This project will benefit additive manufacturing by providing real-time inspection of internal geometry that is not currently possible and reduce the time and cost of additive manufactured parts with automated real-time dimensional inspections which deletes post-production inspections.

  6. Physics of the infrared spectrum

    Science.gov (United States)

    Deming, Drake; Jennings, Donald E.; Jefferies, John; Lindsey, Charles

    1991-01-01

    The IR bandpass is attractive for solar magnetic field studies in virtue of the proportionality to wavelength of the ratio of Zeeman splitting to line width. The large Zeeman splitting and optical thinness of the 12-micron observations render them especially useful for vector magnetic field derivations. The IR continuum, and many IR spectral lines, are formed in LTE and are useful in studies of the temperature structure of the solar atmosphere from the deepest observable photospheric layers to chromospheric altitudes. The far-IR continuum is an excellent thermometer for the upper photosphere and chromosphere.

  7. Estimation of wetland evapotranspiration in northern New York using infrared thermometry

    Science.gov (United States)

    Hwang, K.; Chandler, D. G.

    2016-12-01

    Evapotranspiration (ET) is an important component of the water budget and often regarded as a major water loss. In freshwater wetlands, cumulative annual ET can equal precipitation under well-watered conditions. Wetland ET is therefore an important control on contaminant and nutrient transport. Yet, quantification of wetland ET is challenged by complex surface characteristics, diverse plant species and density, and variations in wetland shape and size. As handheld infrared (IR) cameras have become available, studies exploiting the new technology have increased, especially in agriculture and hydrology. The benefits of IR cameras include (1) high spatial resolution, (2) high sample rates, (3) real-time imaging, (4) a constant viewing geometry, and (5) no need for atmosphere and cloud corrections. Compared with traditional methods, infrared thermometer is capable of monitoring at the scale of a small pond or localized plant community. This enables finer scale survey of heterogeneous land surfaces rather than strict dependence on atmospheric variables. Despite this potential, there has been a limited number of studies of ET and drought stress with IR cameras. In this study, the infrared thermometry-based method was applied to estimate ET over wetland plant species in St. Lawrence River Valley, NY. The results are evaluated with traditional methods to test applicability over multiple vegetation species in a same area.

  8. Infrared-x-ray pump-probe spectroscopy of the NO molecule

    International Nuclear Information System (INIS)

    Guimaraes, F.F.; Felicissimo, V.C.; Kimberg, V.; Gel'mukhanov, F.; Aagren, H.; Cesar, A.

    2005-01-01

    Two color infrared-x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation

  9. Infrared x-ray pump-probe spectroscopy of the NO molecule

    Science.gov (United States)

    Guimarães, F. F.; Kimberg, V.; Felicíssimo, V. C.; Gel'Mukhanov, F.; Cesar, A.; Ågren, H.

    2005-07-01

    Two color infrared x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation.

  10. Infrared source test

    Energy Technology Data Exchange (ETDEWEB)

    Ott, L.

    1994-11-15

    The purpose of the Infrared Source Test (IRST) is to demonstrate the ability to track a ground target with an infrared sensor from an airplane. The system is being developed within the Advance Technology Program`s Theater Missile Defense/Unmanned Aerial Vehicle (UAV) section. The IRST payload consists of an Amber Radiance 1 infrared camera system, a computer, a gimbaled mirror, and a hard disk. The processor is a custom R3000 CPU board made by Risq Modular Systems, Inc. for LLNL. The board has ethernet, SCSI, parallel I/O, and serial ports, a DMA channel, a video (frame buffer) interface, and eight MBytes of main memory. The real-time operating system VxWorks has been ported to the processor. The application code is written in C on a host SUN 4 UNIX workstation. The IRST is the result of a combined effort by physicists, electrical and mechanical engineers, and computer scientists.

  11. Powerful infrared emitting diodes

    Directory of Open Access Journals (Sweden)

    Kogan L. M.

    2012-02-01

    Full Text Available Powerful infrared LEDs with emission wavelength 805 ± 10, 870 ± 20 and 940 ± 10 nm developed at SPC OED "OPTEL" are presented in the article. The radiant intensity of beam diode is under 4 W/sr in the continuous mode and under 100 W/sr in the pulse mode. The radiation power of wide-angle LEDs reaches 1 W in continuous mode. The external quantum efficiency of emission IR diodes runs up to 30%. There also has been created infrared diode modules with a block of flat Fresnel lenses with radiant intensity under 70 W/sr.

  12. NEAR-INFRARED IMAGING OF THE STAR-FORMING REGIONS SH2-157 AND SH2-152

    International Nuclear Information System (INIS)

    Chen Yafeng; Yang Ji; Zeng Qin; Yao Yongqiang; Sato, Shuji

    2009-01-01

    Near-infrared JHK' and H 2 v = 1-0 S (1) imaging observations of the star-forming regions Sh2-157 and Sh2-152 are presented. The data reveal a cluster of young stars associated with H 2 line emission in each region. Additionally, many IR point sources are found in the dense core of each molecular cloud. Most of these sources exhibit infrared color excesses typical of T Tauri stars, Herbig Ae/Be stars, and protostars. Several display the characteristics of massive stars. We calculate histograms of the K'-magnitude and [H - K'] color for all sources, as well as two-color and color-magnitude diagrams. The stellar populations inside and outside the clusters are similar, suggesting that these systems are rather evolved. Shock-driven H 2 emission knots are also detected, which may be related to evident subclusters in an earlier evolutionary stage.

  13. Some observations on the use of the triple points of deuterium and xenon in interpolation schemes for platinum resistance thermometers below 273 K

    International Nuclear Information System (INIS)

    Kemp, R.C.

    1988-01-01

    The use of the triple points of deuterium and xenon is investigated in some interpolation schemes for platinum resistance thermometers between 13.8 K and 273 K. The use of these triple points together is shown to lead to a large sensitivity to errors in the realization of the boiling point of water or the triple point of gallium and of the triple point of xenon for interpolated temperatures below 25 K. The behaviour of these interpolation schemes is presented as evidence that the large non-uniqueness observed in temperature scales between 84 K and 273 K is due in part to measurement errors at the boiling point of water. The use of the triple point of xenon and in interpolation scheme between 25 K and 273 K is shown to lead to a large sensitivity to calibration errors in the triple points of xenon and gallium between 25 K and 54 K. (orig.)

  14. The infrared retina

    International Nuclear Information System (INIS)

    Krishna, Sanjay

    2009-01-01

    As infrared imaging systems have evolved from the first generation of linear devices to the second generation of small format staring arrays to the present 'third-gen' systems, there is an increased emphasis on large area focal plane arrays (FPAs) with multicolour operation and higher operating temperature. In this paper, we discuss how one needs to develop an increased functionality at the pixel level for these next generation FPAs. This functionality could manifest itself as spectral, polarization, phase or dynamic range signatures that could extract more information from a given scene. This leads to the concept of an infrared retina, which is an array that works similarly to the human eye that has a 'single' FPA but multiple cones, which are photoreceptor cells in the retina of the eye that enable the perception of colour. These cones are then coupled with powerful signal processing techniques that allow us to process colour information from a scene, even with a limited basis of colour cones. Unlike present day multi or hyperspectral systems, which are bulky and expensive, the idea would be to build a poor man's 'infrared colour' camera. We use examples such as plasmonic tailoring of the resonance or bias dependent dynamic tuning based on quantum confined Stark effect or incorporation of avalanche gain to achieve embodiments of the infrared retina.

  15. Photographic infrared spectroscopy and near infrared photometry of Be stars

    International Nuclear Information System (INIS)

    Swings, J.P.

    1976-01-01

    Two topics are tackled in this presentation: spectroscopy and photometry. The following definitions are chosen: photographic infrared spectroscopy (wavelengths Hα<=lambda<1.2 μ); near infrared photometry (wavebands: 1.6 μ<=lambda<=20 μ). Near infrared spectroscopy and photometry of classical and peculiar Be stars are discussed and some future developments in the field are outlined. (Auth.)

  16. Infrared thermography of loose hangingwalls

    CSIR Research Space (South Africa)

    Kononov, VA

    2002-09-01

    Full Text Available This project is the continuation of GAP706 “Pre-feasibility investigation of infrared thermography for the identification of loose hangingwall and impending falls of ground”. The main concept behind the infrared thermography method...

  17. Recent advances in infrared astronomy

    International Nuclear Information System (INIS)

    Robson, E.I.

    1980-01-01

    A background survey is given of developments in infrared astronomy during the last decade. Advantages obtained in using infrared wavelengths to penetrate the Earth's atmosphere and the detectors used for this work are considered. Infrared studies of, among other subjects, the stars, dust clouds, the centre of our galaxy and the 3k cosmic background radiation, are discussed. (UK)

  18. Infrared up-conversion microscope

    DEFF Research Database (Denmark)

    2014-01-01

    There is presented an up-conversion infrared microscope (110) arranged for imaging an associated object (130), wherein the up-conversion infrared microscope (110) comprises a non-linear crystal (120) arranged for up-conversion of infrared electromagnetic radiation, and wherein an objective optical...

  19. Infrared up-conversion telescope

    DEFF Research Database (Denmark)

    2014-01-01

    There is presented to an up-conversion infrared telescope (110) arranged for imaging an associated scene (130), wherein the up-conversion infrared telescope (110) comprises a non-linear crystal (120) arranged for up-conversion of infrared electromagnetic radiation, and wherein a first optical...

  20. Infrared emission and extragalactic starbursts

    International Nuclear Information System (INIS)

    Telesco, C.M.

    1985-01-01

    The paper examines the belief that recent star formation plays a significant role in determining many of the infrared properties of galaxies. Pertinent types of infrared observations and the infrared properties of starbursts are briefly summarized. Recently developed models which describe the evolution of starbursts are also considered. (U.K.)

  1. Uncooled tunneling infrared sensor

    Science.gov (United States)

    Kenny, Thomas W. (Inventor); Kaiser, William J. (Inventor); Podosek, Judith A. (Inventor); Vote, Erika C. (Inventor); Muller, Richard E. (Inventor); Maker, Paul D. (Inventor)

    1995-01-01

    An uncooled infrared tunneling sensor in which the only moving part is a diaphragm which is deflected into contact with a micromachined silicon tip electrode prepared by a novel lithographic process. Similarly prepared deflection electrodes employ electrostatic force to control the deflection of a silicon nitride, flat diaphragm membrane. The diaphragm exhibits a high resonant frequency which reduces the sensor's sensitivity to vibration. A high bandwidth feedback circuit controls the tunneling current by adjusting the deflection voltage to maintain a constant deflection of the membrane. The resulting infrared sensor can be miniaturized to pixel dimensions smaller than 100 .mu.m. An alternative embodiment is implemented using a corrugated membrane to permit large deflection without complicated clamping and high deflection voltages. The alternative embodiment also employs a pinhole aperture in a membrane to accommodate environmental temperature variation and a sealed chamber to eliminate environmental contamination of the tunneling electrodes and undesireable accoustic coupling to the sensor.

  2. Wireless infrared computer control

    Science.gov (United States)

    Chen, George C.; He, Xiaofei

    2004-04-01

    Wireless mouse is not restricted by cable"s length and has advantage over its wired counterpart. However, all the mice available in the market have detection range less than 2 meters and angular coverage less than 180 degrees. Furthermore, commercial infrared mice are based on track ball and rollers to detect movements. This restricts them to be used in those occasions where users want to have dynamic movement, such as presentations and meetings etc. This paper presents our newly developed infrared wireless mouse, which has a detection range of 6 meters and angular coverage of 180 degrees. This new mouse uses buttons instead of traditional track ball and is developed to be a hand-held device like remote controller. It enables users to control cursor with a distance closed to computer and the mouse to be free from computer operation.

  3. Infrared Astronomy Satellite

    Science.gov (United States)

    Ferrera, G. A.

    1981-09-01

    In 1982, the Infrared Astronomy Satellite (IRAS) will be launched into a 900-km sun-synchronous (twilight) orbit to perform an unbiased, all-sky survey of the far-infrared spectrum from 8 to 120 microns. Observations telemetered to ground stations will be compiled into an IR astronomy catalog. Attention is given the cryogenically cooled, 60-cm Ritchey-Chretien telescope carried by the satellite, whose primary and secondary mirrors are fabricated from beryllium by means of 'Cryo-Null Figuring'. This technique anticipates the mirror distortions that will result from cryogenic cooling of the telescope and introduces dimensional compensations for them during machining and polishing. Consideration is also given to the interferometric characterization of telescope performance and Cryo/Thermal/Vacuum simulated space environment testing.

  4. Far infrared photoconductors

    International Nuclear Information System (INIS)

    Leotin, J.; Meny, C.

    1990-01-01

    This paper presents the development of far infrared photoconductors for the focal plane of a spaceborne instrument named SAFIRE. SAFIRE (Spectroscopy of the Atmosphere using Far-Infrared Emission) belongs to the EOS program (Earth Observing System) and is now in the definition phase. It is a joint effort by scientists from the United States, Great Britain, Italy and France for a new generation of atmosphere sensor. The overall goal of the SAFIRE experiment is to improve the understanding of the ozone distribution in the middle atmosphere by conducting global scale measurements of the important chemical, radiative and dynamical processes which influence its changes. This will be accomplished by the measurement of the far infrared thermal limb emission in seven spectral channels covering the range 80 to 400 cm -1 with a maximum resolution of 0.004 cm -1 . For example key gases like OH, O, HO 2 , N 2 O 5 will be probed for the first time. Achievement of the required detector sensitivity in the far-infrared imposes the choice of photoconductive detectors operating at liquid helium temperatures. Germanium doped with gallium is selected for six channels whereas germanium doped with beryllium is suitable for the N 2 O 5 channel. Both photoconductors Ge:Ga and Ge:Be benefit from a well established material technology. A better wavelength coverage of channel 1 is achieved by applying a small uniaxial stress of the order of 0.1 GPa on the Ge:Ga photoconductors. The channel 6B wavelength coverage could be improved by using zinc-doped-germanium (Ge:Zn) or, much better, by using a Blocked Impurity band silicon detector doped with antimony (BIB Si:Sb). The later is developed as an optional basis

  5. Infrared thermal annealing device

    International Nuclear Information System (INIS)

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  6. Ultrafast infrared vibrational spectroscopy

    CERN Document Server

    Fayer, Michael D

    2013-01-01

    The past ten years or so have seen the introduction of multidimensional methods into infrared and optical spectroscopy. The technology of multidimensional spectroscopy is developing rapidly and its applications are spreading to biology and materials science. Edited by a recognized leader in the field and with contributions from top researchers, including experimentalists and theoreticians, this book presents the latest research methods and results and will serve as an excellent resource for other researchers.

  7. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, B. R. [BP Research, Cleveland, OH (United States); Nielsen, D. C.; Shock, C. C.

    1992-10-15

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  8. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  9. Delineation of thermal effluents discharged into tropical waters around Puerto Rico by aerial infrared scanning

    International Nuclear Information System (INIS)

    Wood, E.D.

    1975-01-01

    Aerial infrared scanning offers a versatile tool with which to monitor thermal discharges and a rapid method of detecting extraneous discharges, whose temperatures differ from the ambient waters. Knowledge of the extent and distribution of thermal effluents is necessary to assist in determining the effects of the added heat upon biota of the region. An AGA Model 680 Thermovision infrared scanner with a 45 0 lens was mounted in a Cessna 182, and flown at altitudes of 600 to 2000 m during night and twilight hours. The detector was InSb, cooled with liquid nitrogen and sensitive to the range 2 to 5.6 μm. The picture was originally displayed on a color monitor which assigned ten arbitrary colors to shades of gray on the control unit. Isotherms have been assigned using coincidental surface measurements made with a thermometer, read to the nearest 0.1 0 C. The data were then recorded on film. Ranges were set at 2 0 C and 5 0 C, common sensitivities were 0.2 0 C and 0.5 0 C, respectively. More recently, the data have been recorded on magnetic tapes with a Sabre III instrumentation tape recorder. Observed data have been compared to predictions made using the Pritchard Plume Model. Anomalies can be explained by boundary, wind, and tidal effects. (U.S.)

  10. Infrared thermometry and the crop water stress index. I. History, theory, and baselines

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Development of portable infrared thermometers and the definition of the Crop Water Stress Index (CWSI) have led to widespread interest in infrared thermometry to monitor water stress and schedule irrigations. But the CWSI concept is still new and poorly understood by many. The purpose of this paper is to review the definition of CWSI, and the determination and interpretation of the non-water-stressed baselines used to compute CWSI. The non-water-stressed baseline equation normalizes the canopy minus air temperature differential for variations in vapor pressure deficit. Non-water-stressed baselines can be determined empirically from measurements of canopy and air temperatures and vapor pressure deficit, made diurnally on a single day, or at a single time of day over many days, on well-watered plants. The value of the maximum canopy minus air temperature differential under maximum water stress should also be determined empirically. Causes for CWSI values falling outside of the defined 0 to 10 unit range are reviewed. Non-water-stressed baselines may shift with plant growth stage. Effective use of CWSI is dependent on understanding the definition of CWSI, and the proper determination and use of non-water-stressed baselines. (author)

  11. Origins Space Telescope: The Far Infrared Imager and Polarimeter FIP

    Science.gov (United States)

    Staguhn, Johannes G.; Chuss, David; Howard, Joseph; Meixner, Margaret; Vieira, Joaquin; Amatucci, Edward; Bradley, Damon; Carter, Ruth; Cooray, Asantha; Flores, Anel; Leisawitz, David; Moseley, Samuel Harvey; Wollack, Edward; Origins Space Telescope Study Team

    2018-01-01

    The Origins Space Telescope (OST)* is the mission concept for the Far-Infrared Surveyor, one of the four science and technology definition studies of NASA Headquarters for the 2020 Astronomy and Astrophysics Decadal survey. The current "concept 1", which envisions a cold (4K) 9m space telescope, includes 5 instruments, providing a wavelength coverage ranging from 6um and 667um. The achievable sensitivity of the observatory will provide three to four orders of magnitude of improvement in sensitivity over current observational capabilities, allowing to address a wide range of new and so far inaccessible scientific questions, ranging from bio-signatures on exo-planets to mapping primordial H_2 from the "dark ages" before the universe went through the phase of re-ionization.Here we present the Far Infrared Imager and Polarimeter (FIP) for OST. The cameral will cover four bands, 40um, 80um, 120um, and 240um. It will allow for differential polarimetry in those bands with the ability to observe two colors in polarimtery mode simultaneously, while all four bands can be observed simultaneously in total power mode. While the confusion limit will be reached in only 32ms at 240um, at 40um the source density on the sky is so low, that at the angular resolution of 1" of OST at this wavelength there will be no source confusion, even for the longest integration times. Science topics that can be addressed by FIP include but are not limited to galactic and extragalactic magnetic field studies, Deep Galaxy Surveys, and Outer Solar System objects..*Origins will enable flagship-quality general observing programs led by the astronomical community in the 2030s. We welcome you to contact the Science and Technology Definition Team (STDT) with your science needs and ideas by emailing us at ost_info@lists.ipac.caltech.edu

  12. Infrared Astronomy and Star Formation

    International Nuclear Information System (INIS)

    Evans, N.J.

    1985-01-01

    Infrared astronomy is a natural tool to use in studying star formation because infrared light penetrates the surrounding dust and because protostars are expected to emit infrared light. Infrared mapping and photometry have revealed many compact sources, often embedded in more extensive warm dust associated with a molecular cloud core. More detailed study of these objects is now beginning, and traditional interpretations are being questioned. Some compact sources are now thought to be density enhancements which are not self-luminous. Infrared excesses around young stars may not always be caused by circumstellar dust; speckle measurements have shown that at least some of the excess toward T Tauri is caused by an infrared companion. Spectroscopic studies of the dense, star-forming cores and of the compact objects themselves have uncovered a wealth of new phenomena, including the widespread occurence of energetic outflows. New discoveries with IRAS and with other planned infrared telescopes will continue to advance this field. (author)

  13. Irrigation scheduling of spring wheat using infrared thermometry

    International Nuclear Information System (INIS)

    Stegman, E.C.; Soderlund, M.G.

    1989-01-01

    Irrigation scheduling for spring wheat requires information on different irrigation timing methods. Irrigation timing based on allowable root zone available water depletion and selected crop water stress index (CWSI) thresholds were evaluated in terms of their effect on spring wheat yield. A field study was conducted at Oakes, North Dakota in 1987 and 1988 on a Maddock sandy loam soil with two varieties of spring wheat (Marshall and Wheaton) using a split plot randomized block design. Irrigation was metered to each plot using trickle irrigation tubing. Neutron soil water measurements along with a water balance model were used to time irrigations that were based on different allowed root zone depletions. Infrared thermometer sensors (IRT) were used to measure in situ canopy temperatures and along with measured climatic information were used to time irrigations using the CWSI approach. Additionally, crop phenological stages and final grain yield were measured. The non-water-stressed baselines necessary for the CWSI differed between the two seasons but were similar to those from previous studies. The CWSI methods were feasible from the Feekes scale S4 (beginning pseudo-stem) to S11.2 (mealy ripe). Minimal yield reductions were observed using the CWSI method for thresholds less than 0.4-0.5 during this period. Minimal yield reductions were observed by maintaining the root zone allowable depletion below 50%. The grain yield-evapotranspiration (ET) relationship was linear in both years but with different slopes and intercepts. When analyzed on a relative basis to maximum ET (ETm), a single relationship fit both years’ data with a yield sensitivity factor of 1.58. Irrigations timed at CWSI = 0.5 reduced seasonal water application by 18% relative to treatments irrigated at CWSI = 0.2. (author)

  14. Infrared diffuse interstellar bands

    Science.gov (United States)

    Galazutdinov, G. A.; Lee, Jae-Joon; Han, Inwoo; Lee, Byeong-Cheol; Valyavin, G.; Krełowski, J.

    2017-05-01

    We present high-resolution (R ˜ 45 000) profiles of 14 diffuse interstellar bands in the ˜1.45 to ˜2.45 μm range based on spectra obtained with the Immersion Grating INfrared Spectrograph at the McDonald Observatory. The revised list of diffuse bands with accurately estimated rest wavelengths includes six new features. The diffuse band at 15 268.2 Å demonstrates a very symmetric profile shape and thus can serve as a reference for finding the 'interstellar correction' to the rest wavelength frame in the H range, which suffers from a lack of known atomic/molecular lines.

  15. Infrared upconversion hyperspectral imaging

    DEFF Research Database (Denmark)

    Kehlet, Louis Martinus; Tidemand-Lichtenberg, Peter; Dam, Jeppe Seidelin

    2015-01-01

    In this Letter, hyperspectral imaging in the mid-IR spectral region is demonstrated based on nonlinear frequency upconversion and subsequent imaging using a standard Si-based CCD camera. A series of upconverted images are acquired with different phase match conditions for the nonlinear frequency...... conversion process. From this, a sequence of monochromatic images in the 3.2-3.4 mu m range is generated. The imaged object consists of a standard United States Air Force resolution target combined with a polystyrene film, resulting in the presence of both spatial and spectral information in the infrared...... image. (C) 2015 Optical Society of America...

  16. Thermography by Infrared

    International Nuclear Information System (INIS)

    Harara, W.; Allouch, Y.; Altahan, A.

    2015-08-01

    This study focused on the principle’s explanation of metallic components and structures testing by thermography method using infrared waves. The study confirmed that, thermal waves testing technique as one of the most important method among the modern non-destructive testing methods. It is characterized by its economy, easy to apply and timely testing of components and metallic structures. This method is applicable to a wide variety of components such as testing pieces of planes, power plants, electric transmission lines and aerospace components, in order to verify their structures and fabrication quality and their comformance to the international standards.Testing the components by thermography using infrared radiation is easy and rapid if compared to other NDT methods. The study included an introduction to the thermography testing method, its equipements, components and the applied technique. Finally, two practical applications are given in order to show the importance of this method in industry concerned with determining the liquid level in a tank and testing the stability of the control box of electrical supply.(author)

  17. Low background infrared (LBIR) facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Low background infrared (LBIR) facility was originally designed to calibrate user supplied blackbody sources and to characterize low-background IR detectors and...

  18. Infrared emission from supernova condensates

    International Nuclear Information System (INIS)

    Dwek, E.; Werner, M.W.

    1981-01-01

    We examine the possibility of detecting grains formed in supernovae by observations of their emission in the infrared. The basic processes determining the temperature and infrared radiation of grains in supernovae environments are analyzed, and the results are used to estimate the infrared emission from the highly metal enriched ''fast moving knots'' in Cas A. The predicted fluxes lie within the reach of current ground-based facilities at 10 μm, and their emission should be detectable throughout the infrared band with cryogenic space telescopes

  19. Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

    Science.gov (United States)

    Stevenson, T. R.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Lee, S.-J.; Nagler, P. C.; Smith, S. J.

    2015-01-01

    We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

  20. CINE: Comet INfrared Excitation

    Science.gov (United States)

    de Val-Borro, Miguel; Cordiner, Martin A.; Milam, Stefanie N.; Charnley, Steven B.

    2017-08-01

    CINE calculates infrared pumping efficiencies that can be applied to the most common molecules found in cometary comae such as water, hydrogen cyanide or methanol. One of the main mechanisms for molecular excitation in comets is the fluorescence by the solar radiation followed by radiative decay to the ground vibrational state. This command-line tool calculates the effective pumping rates for rotational levels in the ground vibrational state scaled by the heliocentric distance of the comet. Fluorescence coefficients are useful for modeling rotational emission lines observed in cometary spectra at sub-millimeter wavelengths. Combined with computational methods to solve the radiative transfer equations based, e.g., on the Monte Carlo algorithm, this model can retrieve production rates and rotational temperatures from the observed emission spectrum.

  1. Infrared Quenched Photoinduced Superconductivity

    Science.gov (United States)

    Federici, J. F.; Chew, D.; Guttierez-Solana, J.; Molina, G.; Savin, W.; Wilber, W.

    1996-03-01

    Persistant photoconductivity (PPC) and photoinduced superconductivity (PISC) in oxygen deficient YBa_2Cu_3O_6+x have received recent attention. It has been suggested that oxygen vacancy defects play an important role in the PISC/PPC mechanism.(J. F. Federici, D. Chew, B. Welker, W. Savin, J. Gutierrez-Solana, and T. Fink, Phys. Rev. B), December 1995 Supported by National Science Foundation In this model, defects trap photogenerated electrons so that electron-hole recombination can not occur thereby allowing photogenerated holes to contribute to the carrier density. Nominally, the photoinduced state is long-lived, persisting for days at low temperature. Experiment results will be presented demonstrating that the photoinduced superconductivity state can be quenched using infrared radiation. Implications for the validity of the PISC/PCC defect model will be discussed.

  2. Near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Virendra Jain

    2015-01-01

    Full Text Available Tissue ischaemia can be a significant contributor to increased morbidity and mortality. Conventional oxygenation monitoring modalities measure systemic oxygenation, but regional tissue oxygenation is not monitored. Near-infrared spectroscopy (NIRS is a non-invasive monitor for measuring regional oxygen saturation which provides real-time information. There has been increased interest in the clinical application of NIRS following numerous studies that show improved outcome in various clinical situations especially cardiac surgery. Its use has shown improved neurological outcome and decreased postoperative stay in cardiac surgery. Its usefulness has been investigated in various high risk surgeries such as carotid endarterectomy, thoracic surgeries, paediatric population and has shown promising results. There is however, limited data supporting its role in neurosurgical population. We strongly feel, it might play a key role in future. It has significant advantages over other neuromonitoring modalities, but more technological advances are needed before it can be used more widely into clinical practice.

  3. Terahertz and Mid Infrared

    CERN Document Server

    Shulika, Oleksiy; Detection of Explosives and CBRN (Using Terahertz)

    2014-01-01

    The reader will find here a timely update on new THz sources and detection schemes as well as concrete applications to the detection of Explosives and CBRN. Included is a method to identify hidden RDX-based explosives (pure and plastic ones) in the frequency domain study by Fourier Transformation, which has been complemented by the demonstration of improvement of the quality of the images captured commercially available THz passive cameras. The presented examples show large potential for the detection of small hidden objects at long distances (6-10 m).  Complementing the results in the short-wavelength range, laser spectroscopy with a mid-infrared, room temperature, continuous wave, DFB laser diode and high performance DFB QCL have been demonstrated to offer excellent enabling sensor technologies for environmental monitoring, medical diagnostics, industrial and security applications.  From the new source point of view a number of systems have been presented - From superconductors to semiconductors, e.g. Det...

  4. Infrared laser system

    International Nuclear Information System (INIS)

    Cantrell, C.D.; Carbone, R.J.

    1977-01-01

    An infrared laser system and method for isotope separation may comprise a molecular gas laser oscillator to produce a laser beam at a first wavelength, Raman spin flip means for shifting the laser to a second wavelength, a molecular gas laser amplifier to amplify said second wavelength laser beam to high power, and optical means for directing the second wavelength, high power laser beam against a desired isotope for selective excitation thereof in a mixture with other isotopes. The optical means may include a medium which shifts the second wavelength high power laser beam to a third wavelength, high power laser beam at a wavelength coincidental with a corresponding vibrational state of said isotope and which is different from vibrational states of other isotopes in the gas mixture

  5. Mid-infrared upconversion spectroscopy

    DEFF Research Database (Denmark)

    Tidemand-Lichtenberg, Peter; Dam, Jeppe Seidelin; Andersen, H. V.

    2016-01-01

    Mid-infrared (MIR) spectroscopy is emerging as an attractive alternative to near-infrared or visible spectroscopy. MIR spectroscopy offers a unique possibility to probe the fundamental absorption bands of a large number of gases as well as the vibrational spectra of complex molecules. In this paper...

  6. Infrared observation of the early universe

    International Nuclear Information System (INIS)

    Matsumoto, T.

    1984-01-01

    The rocket observation of the near-infrared extragalactic background radiation and its influence on the cosmology are described. The furute plans to observe the near-infrared and far-infrared backgrounds are also presented. (author)

  7. Broadband infrared beam splitter for spaceborne interferometric infrared sounder.

    Science.gov (United States)

    Yu, Tianyan; Liu, Dingquan; Qin, Yang

    2014-10-01

    A broadband infrared beam splitter (BS) on ZnSe substrate used for the spaceborne interferometric infrared sounder (SIIRS) is studied in the spectral range of 4.44-15 μm. Both broadband antireflection coating and broadband beam-splitter coating in this BS are designed and tested. To optimize the optical properties and the stability of the BS, suitable infrared materials were selected, and improved deposition techniques were applied. The designed structures matched experimental data well, and the properties of the BS met the application specification of SIIRS.

  8. Semiconductor optoelectronic infrared spectroscopy

    International Nuclear Information System (INIS)

    Hollingworth, A.R.

    2001-08-01

    We use spectroscopy to study infrared optoelectronic inter and intraband semiconductor carrier dynamics. The overall aim of this thesis was to study both III-V and Pb chalcogenide material systems in order to show their future potential use in infrared emitters. The effects of bandstructure engineering have been studied in the output characteristics of mid-IR III-V laser diodes to show which processes (defects, radiative, Auger and phonon) dominate and whether non-radiative processes can be suppressed. A new three-beam pump probe experiment was used to investigate interband recombination directly in passive materials. Experiments on PbSe and theory for non-parabolic near-mirror bands and non-degenerate statistics were in good agreement. Comparisons with HgCdTe showed a reduction in the Auger coefficient of 1-2 orders of magnitude in the PbSe. Using Landau confinement to model spatial confinement in quantum dots (QDs) 'phonon bottlenecking' was studied. The results obtained from pump probe and cyclotron resonance saturation measurements showed a clear suppression in the cooling of carriers when Landau level separation was not resonant with LO phonon energy. When a bulk laser diode was placed in a magnetic field to produce a quasi quantum wire device the resulting enhanced differential gain and reduced Auger recombination lowered I th by 30%. This result showed many peaks in the light output which occurred when the LO phonon energy was a multiple of the Landau level separation. This showed for the first time evidence of the phonon bottleneck in a working laser device. A new technique called time resolved optically detected cyclotron resonance, was used as a precursor to finding the carrier dynamics within a spatially confined quantum dot. By moving to the case of a spatial QD using an optically detected intraband resonance it was possible to measure the energy separation interband levels and conduction and valence sublevels within the dot simultaneously. Furthermore

  9. Acceptability of the Distress Thermometer and Problem List to community-based telephone cancer helpline operators, and to cancer patients and carers

    Directory of Open Access Journals (Sweden)

    Sargeant Hilary

    2011-01-01

    Full Text Available Abstract Background Cancer can be a distressing experience for cancer patients and carers, impacting on psychological, social, physical and spiritual functioning. However, health professionals often fail to detect distress in their patients due to time constraints and a lack of experience. Also, with the focus on the patient, carer needs are often overlooked. This study investigated the acceptability of brief distress screening with the Distress Thermometer (DT and Problem List (PL to operators of a community-based telephone helpline, as well as to cancer patients and carers calling the service. Methods Operators (n = 18 monitored usage of the DT and PL with callers (cancer patients/carers, >18 years, and English-speaking from September-December 2006 (n = 666. The DT is a single item, 11-point scale to rate level of distress. The associated PL identifies the cause of distress. Results The DT and PL were used on 90% of eligible callers, most providing valid responses. Benefits included having an objective, structured and consistent means for distress screening and triage to supportive care services. Reported challenges included apparent inappropriateness of the tools due to the nature of the call or level of caller distress, the DT numeric scale, and the level of operator training. Conclusions We observed positive outcomes to using the DT and PL, although operators reported some challenges. Overcoming these challenges may improve distress screening particularly by less experienced clinicians, and further development of the PL items and DT scale may assist with administration. The DT and PL allow clinicians to direct/prioritise interventions or referrals, although ongoing training and support is critical in distress screening.

  10. Assessment of psychological distress among Asian adolescents and young adults (AYA) cancer patients using the distress thermometer: a prospective, longitudinal study.

    Science.gov (United States)

    Chan, Alexandre; Poon, Eileen; Goh, Wei Lin; Gan, Yanxiang; Tan, Chia Jie; Yeo, Kelvin; Chua, Annabelle; Chee, Magdalene; Law, Yi Chye; Somasundaram, Nagavalli; Kanesvaran, Ravindran; Ng, Quan Sing; Tham, Chee Kian; Toh, Chee Keong; Lim, Soon Thye; Tao, Miriam; Tang, Tiffany; Quek, Richard; Farid, Mohamad

    2018-04-11

    Since few studies have investigated whether the Distress Thermometer (DT) in Asian adolescent and young adult (AYA) cancer patients (between 15 and 39 years), we investigated the appropriateness of the DT as a screening tool for psychological symptom burden in these AYA patients and to evaluate AYA patients' distress across a trajectory of three time points longitudinally over a 6-month period. This was a prospective, longitudinal study. Recruited Asian AYA patients were diagnosed with lymphomas, sarcomas, primary brain malignancies, or germ cell tumors. Patients completed the DT, PedsQL Generic Core Scales, and the Rotterdam Symptom Checklist. Data were analyzed using STATA version 15. Approximately half of the patients experienced clinically significant DT distress (distress score ≥ 4) early in their cancer journey with 43.1% patients presenting with distress at time of diagnosis and 47.7% patients 1 month after diagnosis. Among AYA patients > 24 years old, worry (68.3%), insurance/financial issues (61%), treatment decisions (43.9%), work/school issues (41.5%), nervousness (41.5%), and sadness (41.5%) were the top five identified problems. On the other hand, the top five identified problems among AYA ≤ 24 years were worry (54.2%), nervousness (41.7%), bathing/dressing problems (37.5%), work/school issues (33.3%), and fatigue (33.3%). DT scores were significantly associated with certain psychological symptom burden items such as worry (p psychological distress in AYA cancer patients with clinically significant distress being identified in the early phases of the cancer journey.

  11. A pilot study on the usefulness of peripheral blood flow cytometry for the diagnosis of lower risk myelodysplastic syndromes: the "MDS thermometer".

    Science.gov (United States)

    Aires, Ana; Teixeira, Maria Dos Anjos; Lau, Catarina; Moreira, Cláudia; Spínola, Ana; Mota, Alexandra; Freitas, Inês; Coutinho, Jorge; Lima, Margarida

    2018-01-01

    Immunophenotypic analysis of the bone marrow (BM) cells has proven to be helpful in the diagnosis of Myelodysplastic Syndromes (MDS). However, the usefulness of flow cytometry (FCM) for the detection of myelodysplasia in the peripheral blood (PB) still needs to be investigated. The aim of this pilot study was to evaluate the value of FCM-based PB neutrophil and monocyte immunophenotyping for the diagnosis of lower risk MDS (LR-MDS). We evaluated by 8-color FCM the expression of multiple cell surface molecules (CD10, CD11b, CD11c, CD13, CD14, CD15, CD16, CD34, CD45, CD56, CD64 and HLA-DR) in PB neutrophils and monocytes from a series of 14 adult LR-MDS patients versus 14 normal individuals. Peripheral blood neutrophils from patients with LR-MDS frequently had low forward scatter (FSC) and side scatter (SSC) values and low levels of CD11b, CD11c, CD10, CD16, CD13 and CD45 expression, in that order, as compared to normal neutrophils. In addition, patients with LR-MDS commonly display a higher fraction of CD14 + CD56 + and a lower fraction of CD14 + CD16 + monocytes in the PB. Based on these results, we proposed an immunophenotyping score based on which PB samples from patients with LR-MDS could be distinguished from normal PB samples with a sensitivity 93% and a specificity of 100%. In addition, we used this score to construct the MDS Thermometer, a screening tool for detection and monitoring of MDS in the PB in clinical practice. Peripheral blood neutrophil and monocyte immunophenotyping provide useful information for the diagnosis of LR-MDS, as a complement to cytomorphology. If validated by subsequent studies in larger series of MDS patients and extended to non-MDS patients with cytopenias, our findings may improve the diagnostic assessment and avoid invasive procedures in selected groups of MDS patients.

  12. Infrared monitoring of combustion

    International Nuclear Information System (INIS)

    Bates, S.C.; Morrison, P.W. Jr.; Solomon, P.R.

    1991-01-01

    In this paper, the use of Fourier Transform Infrared (FT-IR) spectroscopy for combustion monitoring is described. A combination of emission, transmission, and reflection FT-IR spectroscopy yields data on the temperature and composition of the gases, surfaces and suspended particles in the combustion environment. Detection sensitivity of such trace exhaust gases as CO, CO 2 , SO 2 , NO x , and unburned hydrocarbons is at the ppm level. Tomographic reconstruction converts line-of-sight measurements into spatially resolved temperature and concentration data. Examples from various combustion processes are used to demonstrate the capabilities of the technique. Industrial measurements are described that have been performed directly in the combustion zone and in the exhaust duct of a large chemical recovery boiler. Other measurements of hot slag show how FT-IR spectroscopy can determine the temperature and optical properties of surfaces. In addition, experiments with water droplets show that transmission FT-IR data yield spectra that characterize particle size and number density

  13. Solar and infrared radiation measurements

    CERN Document Server

    Vignola, Frank; Michalsky, Joseph

    2012-01-01

    The rather specialized field of solar and infrared radiation measurement has become more and more important in the face of growing demands by the renewable energy and climate change research communities for data that are more accurate and have increased temporal and spatial resolution. Updating decades of acquired knowledge in the field, Solar and Infrared Radiation Measurements details the strengths and weaknesses of instruments used to conduct such solar and infrared radiation measurements. Topics covered include: Radiometer design and performance Equipment calibration, installation, operati

  14. Wavelength standards in the infrared

    CERN Document Server

    Rao, KN

    2012-01-01

    Wavelength Standards in the Infrared is a compilation of wavelength standards suitable for use with high-resolution infrared spectrographs, including both emission and absorption standards. The book presents atomic line emission standards of argon, krypton, neon, and xenon. These atomic line emission standards are from the deliberations of Commission 14 of the International Astronomical Union, which is the recognized authority for such standards. The text also explains the techniques employed in determining spectral positions in the infrared. One of the techniques used includes the grating con

  15. Technique for measuring cooling patterns in ion source grids by infrared scanning

    International Nuclear Information System (INIS)

    Grisham, L.R.; Eubank, H.P.; Kugel, H.W.

    1980-02-01

    Many plasma sources designed for neutral beam injection heating of plasmas now employ copper beam acceleration grids which are water-cooled by small capillary tubes fed from one or more headers. To prevent thermally-induced warpage of these grids it is essential that one be able to detect inhomogeneities in the cooling. Due to the very strong thermal coupling between adjacent cooling lines and the concomitant rapid equilibration times, it is not practical to make such measurements in a direct manner with a contact thermometer. We have developed a technique whereby we send a burst of hot water through an initially cool grid, followed by a burst of cool water, and record the transient thermal behavior usng an infrared television camera. This technique, which would be useful for any system with cooling paths that are strongly coupled thermally, has been applied to a number of sources built for the PLT and PDX tokamaks, and has proven highly effective in locating cooling deficiencies and blocked capillary tubes

  16. Retinex enhancement of infrared images.

    Science.gov (United States)

    Li, Ying; He, Renjie; Xu, Guizhi; Hou, Changzhi; Sun, Yunyan; Guo, Lei; Rao, Liyun; Yan, Weili

    2008-01-01

    With the ability of imaging the temperature distribution of body, infrared imaging is promising in diagnostication and prognostication of diseases. However the poor quality of the raw original infrared images prevented applications and one of the essential problems is the low contrast appearance of the imagined object. In this paper, the image enhancement technique based on the Retinex theory is studied, which is a process that automatically retrieve the visual realism to images. The algorithms, including Frackle-McCann algorithm, McCann99 algorithm, single-scale Retinex algorithm, multi-scale Retinex algorithm and multi-scale Retinex algorithm with color restoration, are experienced to the enhancement of infrared images. The entropy measurements along with the visual inspection were compared and results shown the algorithms based on Retinex theory have the ability in enhancing the infrared image. Out of the algorithms compared, MSRCR demonstrated the best performance.

  17. Mid-infrared spectroscopic investigation

    International Nuclear Information System (INIS)

    Walter, L.; Vergo, N.; Salisbury, J.W.

    1987-01-01

    Mid-infrared spectroscopic research efforts are discussed. The development of a new instrumentation to permit advanced measurements in the mid-infrared region of the spectrum, the development of a special library of well-characterized mineral and rock specimens for interpretation of remote sensing data, and cooperative measurements of the spectral signatures of analogues of materials that may be present on the surfaces of asteroids, planets or their Moons are discussed

  18. Infrared Radiation and Blackbody Radiation

    OpenAIRE

    2005-01-01

    tut present graph Tutorial Presentation Graph Interactive Media Element This interactive tutorial covers the following: How infrared radiation was discovered., The regions of infrared radiation and their relations to temperature., The nature of blackbody radiation and Planck's radiation law., The relationship between temperature and the power emitted by radiation.The interactions in this tutorial include clicking to reveal new information, and questions that help students...

  19. Viability of infrared FEL facilities

    International Nuclear Information System (INIS)

    Schwettman, H.A.

    2004-01-01

    Infrared FELs have broken important ground in optical science in the past decade. The rapid development of optical parametric amplifiers and oscillators, and THz sources, however, has changed the competitive landscape and compelled FEL facilities to identify and exploit their unique advantages. The viability of infrared FEL facilities depends on targeting unique world-class science and providing adequate experimental beam time at competitive costs

  20. Infrared Drying Parameter Optimization

    Science.gov (United States)

    Jackson, Matthew R.

    In recent years, much research has been done to explore direct printing methods, such as screen and inkjet printing, as alternatives to the traditional lithographic process. The primary motivation is reduction of the material costs associated with producing common electronic devices. Much of this research has focused on developing inkjet or screen paste formulations that can be printed on a variety of substrates, and which have similar conductivity performance to the materials currently used in the manufacturing of circuit boards and other electronic devices. Very little research has been done to develop a process that would use direct printing methods to manufacture electronic devices in high volumes. This study focuses on developing and optimizing a drying process for conductive copper ink in a high volume manufacturing setting. Using an infrared (IR) dryer, it was determined that conductive copper prints could be dried in seconds or minutes as opposed to tens of minutes or hours that it would take with other drying devices, such as a vacuum oven. In addition, this study also identifies significant parameters that can affect the conductivity of IR dried prints. Using designed experiments and statistical analysis; the dryer parameters were optimized to produce the best conductivity performance for a specific ink formulation and substrate combination. It was determined that for an ethylene glycol, butanol, 1-methoxy 2- propanol ink formulation printed on Kapton, the optimal drying parameters consisted of a dryer height of 4 inches, a temperature setting between 190 - 200°C, and a dry time of 50-65 seconds depending on the printed film thickness as determined by the number of print passes. It is important to note that these parameters are optimized specifically for the ink formulation and substrate used in this study. There is still much research that needs to be done into optimizing the IR dryer for different ink substrate combinations, as well as developing a

  1. Transient Infrared Emission Spectroscopy

    Science.gov (United States)

    Jones, Roger W.; McClelland, John F.

    1989-12-01

    Transient Infrared Emission Spectroscopy (TIRES) is a new technique that reduces the occurrence of self-absorption in optically thick solid samples so that analytically useful emission spectra may be observed. Conventional emission spectroscopy, in which the sample is held at an elevated, uniform temperature, is practical only for optically thin samples. In thick samples the emission from deep layers of the material is partially absorbed by overlying layers.1 This self-absorption results in emission spectra from most optically thick samples that closely resemble black-body spectra. The characteristic discrete emission bands are severely truncated and altered in shape. TIRES bypasses this difficulty by using a laser to heat only an optically thin surface layer. The increased temperature of the layer is transient since the layer will rapidly cool and thicken by thermal diffusion; hence the emission collection must be correlated with the laser heating. TIRES may be done with both pulsed and cw lasers.2,3 When a pulsed laser is used, the spectrometer sampling must be synchronized with the laser pulsing so that only emission during and immediately after each laser pulse is observed.3 If a cw laser is used, the sample must move rapidly through the beam. The hot, transient layer is then in the beam track on the sample at and immediately behind the beam position, so the spectrometer field of view must be limited to this region near the beam position.2 How much self-absorption the observed emission suffers depends on how thick the heated layer has grown by thermal diffusion when the spectrometer samples the emission. Use of a pulsed laser synchronized with the spectrometer sampling readily permits reduction of the time available for heat diffusion to about 100 acs .3 When a cw laser is used, the heat-diffusion time is controlled by how small the spectrometer field of view is and by how rapidly the sample moves past within this field. Both a very small field of view and a

  2. A Micromachined Infrared Senor for an Infrared Focal Plane Array

    Directory of Open Access Journals (Sweden)

    Seong M. Cho

    2008-04-01

    Full Text Available A micromachined infrared sensor for an infrared focal plane array has been designed and fabricated. Amorphous silicon was used as a sensing material, and silicon nitride was used as a membrane material. To get a good absorption in infrared range, the sensor structure was designed as a l/4 cavity structure. A Ni-Cr film was selected as an electrode material and mixed etching scheme was applied in the patterning process of the Ni-Cr electrode. All the processes were made in 0.5 μm iMEMS fabricated in the Electronics and Telecommunication Research Institute (ETRI. The processed MEMS sensor had a small membrane deflection less than 0.15 μm. This small deflection can be attributed to the rigorous balancing of the stresses of individual layers. The efficiency of infrared absorption was more than 75% in the wavelength range of 8 ~ 14 μm. The processed infrared sensor showed high responsivity of ~230 kV/W at 1.0V bias and 2 Hz operation condition. The time constant of the sensor was 8.6 msec, which means that the sensor is suitable to be operated in 30 Hz frame rate.

  3. Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry

    International Nuclear Information System (INIS)

    Williams, E M; Heusch, A I; McCarthy, P W

    2008-01-01

    Non-contact infrared thermometry of facial skin offers advantages over less accessible internal body sites, especially when considering mass screening for febrile infectious disease. The forehead offers an obvious site, but does not present an isothermic surface, as various small arteries passing close to the surface create 'hot-spots'. The aim of this study is to use non-contact infrared (IR) thermometry to determine the link between the temperature at specific facial skin sites and clinical body temperature. A sample of 169 asymptomatic adults (age range 18–54 years) was screened with IR thermometers (Braun Thermoscan proLT for auditory meatus (AM) temperature representing clinical body temperature, and a Raytek, Raynger MX for skin surface temperature). Peak IR skin temperature was measured over the course of each posterior auricular artery (PAA) and each superficial temporal artery (STA). In a sub-group (n = 54) the peak skin temperature of the forehead's metopic region (MR) was also recorded. There were no differences (P > 0.05) between the PAA and STA at 34.2 ± 0.9 °C and 34.2 ± 0.7 °C, respectively, which were 2.5 °C cooler than the AM temperature (36.7 ± 0.5 °C, p 2 = 0.63, p < 0.001) between PAA and STA. There were no asymmetric temperature differences between the left and right sides and males had warmer skin over the MR (F, 33.6 ± 0.7 °C versus M, 34.4 ± 0.6 °C, p < 0.001). Although a lack of correlation between either PAA or STA and AM was apparent in asymptomatics, further research in symptomatics is required to determine the usefulness of these measurements in mass screening of conditions such as fever

  4. Infrared radiation from dark globules

    International Nuclear Information System (INIS)

    Spencer, R.G.; Leung, C.M.

    1978-01-01

    Theoretical models are constructed by which to study the infrared emission from dark globules heated by the interstellar radiation field (ISRF). The effects of cloud parameters (grain type, optical depth, and density inhomogeneity) on the emergent spectrum and infrared surface brightnesses are studied. Compared with clouds which have internal heat sources, the emergent flux for globules is found to be at least a factor of 10 smaller and to peak at wavelengths 100 μm< or =lambda< or =130 μm for graphite clouds and 310 μm< or =lambda< or =550 μm for silicate clouds. Either limb brightening or limb darkening in the infrared can occur, which depends sensitively on the optical depth. For globules of moderate extinction (greater than approx.10 in the visible), significant infrared limb brightening occurs at wavelengths of grain emission (20 μm< or =lambda< or =600 μm). A physical interpretation of these results is presented. To help remove ambiguities from interpretations of future observations, the observable effects of a grain mixture, variation of the ISRF, as well as beam dilution are examined in detail. The presence of a second grain component alters the emergent spectrum significantly. For a variation of the ISRF within wide limits, the ratio of surface to central temperature (T/sub s//T/sub c/) of an optically thick cloud remains fairly constant (3< or approx. =T/sub s//T/sub c/< or approx. =4). Infrared limb brightening may be smoothed out by beam dilution as well as by density inhomogeneities. Finally, the expected flux densities in the infrared of a typical globule are presented for different beam sizes. The predicted fluxes are within the detection threshold of currently available infrared detectors, using either ground-based or balloon-borne telescopes

  5. Stability and Repeatability of the Distress Thermometer (DT and the Edmonton Symptom Assessment System-Revised (ESAS-r with Parents of Childhood Cancer Survivors.

    Directory of Open Access Journals (Sweden)

    Tatsiana Leclair

    Full Text Available Parents report psychological distress in association with their child's cancer. Reliable tools are needed to screen parental distress over the cancer trajectory. This study aimed to estimate the stability and repeatability of the Distress Thermometer (DT and the Depression and Anxiety items of the Edmonton Symptom Assessment System-revised (ESAS-r-D; -A in parents of children diagnosed with cancer.Fifty parents (28 mothers, median age = 44 of clinically stable survivors of childhood solid and brain tumours completed questionnaires about their own distress (DT, ESAS-r-D; -A, Brief Symptom Inventory-18: BSI-18, Patient Health Questionnaire-9: PHQ-9, Generalized Anxiety Disorder-7: GAD-7 and their children's quality of life (QoL; Peds Quality of Life: PedsQL twice, with a month interval between the two assessments. At retest, parents also evaluated life events that occurred between the two time points. Hierarchical regressions explored moderators for the temporal stability of test measures.Stability estimates were ICC = .78 for the DT, .55 for the ESAS-r-D, and .47 for the ESAS-r-A. Caseness agreement between test and retest was substantial for the DT, fair for the ESAS-r-D, and slight for the ESAS-r-A. Repeatability analyses indicated that the error range for the DT was more than 2 pts below/above actual measurement, whereas it was more than 3 pts for the ESAS-r-A, and 2.5 for the ESAS-r-D. Instability of the DT could be explained by changes in children's physical QoL, but not by other components of QoL or life events. No moderators of stability could be identified for the ESAS-r items.The DT appears to be a fairly stable measure when the respondent's condition is stable yet with a relatively wide error range. Fluctuations in distress-related constructs may affect the temporal stability of the DT. The lower stability of ESAS-r items may result from shorter time-lapse instructions resulting in a greater sensitivity to change. Findings support

  6. A Crystallization-Temperature Profile Through Paleo-Oceanic Crust (Wadi Gideah Transect, Oman Ophiolite): Application of the REE-in-Plagioclase-Clinopyroxene Partitioning Thermometer

    Science.gov (United States)

    Mueller, S.; Hasenclever, J.; Garbe-Schönberg, D.; Koepke, J.; Hoernle, K.

    2017-12-01

    The accretion mechanisms forming oceanic crust at fast spreading ridges are still under controversial discussion. Thermal, petrological, and geochemical observations predict different end-member models, i.e., the gabbro glacier and the sheeted sill model. They all bear implications for heat transport, temperature distribution, mode of crystallization and hydrothermal heat removal over crustal depth. In a typical MOR setting, temperature is the key factor driving partitioning of incompatible elements during crystallization. LA-ICP-MS data for co-genetic plagioclase and clinopyroxene in gabbros along a transect through the plutonic section of paleo-oceanic crust (Wadi Gideah Transect, Oman ophiolite) reveal that REE partitioning coefficients are relatively constant in the layered gabbro section but increase for the overlying foliated gabbros, with an enhanced offset towards HREEs. Along with a systematic enrichment of REE's with crustal height, these trends are consistent with a system dominated by in-situ crystallization for the lower gabbros and a change in crystallization mode for the upper gabbros. Sun and Liang (2017) used experimental REE partitioning data for calibrating a new REE-in-plagioclase-clinopyroxene thermometer that we used here for establishing the first crystallization-temperature depth profile through oceanic crust that facilitates a direct comparison with thermal models of crustal accretion. Our results indicate crystallization temperatures of about 1220±8°C for the layered gabbros and lower temperatures of 1175±8°C for the foliated gabbros and a thermal minimum above the layered-to-foliated gabbro transition. Our findings are consistent with a hybrid accretion model for the oceanic crust. The thermal minimum is assumed to represent a zone where the descending crystal mushes originating from the axial melt lens meet with mushes that have crystallized in situ. These results can be used to verify and test thermal models (e.g., Maclennan et al

  7. Numerical study of dense adjoint matter in two color QCD

    International Nuclear Information System (INIS)

    Hands, S.; Morrison, S.; Scorzato, L.; Oevers, M.

    2000-06-01

    We identify the global symmetries of SU(2) lattice gauge theory with N flavors of staggered fermion in the presence of a quark chemical potential μ, for fermions in both fundamental and adjoint representations, and anticipate likely patterns of symmetry breaking at both low and high densities. Results from numerical simulations of the model with N=1 adjoint flavor on a 4 3 x 8 lattice are presented, using both hybrid Monte Carlo and two-step multi-boson algorithms. It is shown that the sign of the fermion determinant starts to fluctuate once the model enters a phase with non-zero baryon charge density. HMC simulations are not ergodic in this regime, but TSMB simulations retain ergodicity even in the dense phase, and in addition appear to show superior decorrelation. The HMC results for the equation of state and the pion mass show good quantitative agreement with the predictions of chiral perturbation theory, which should hold only for N≥2. The TSMB results incorporating the sign of the determinant support a delayed onset transition, consistent with the pattern of symmetry breaking expected for N=1. (orig.)

  8. Calibration of TOB+ Thermometer's Cards

    CERN Document Server

    Banitt, Daniel

    2014-01-01

    Motivation - Under the new upgrade of the CMS detector the working temperature of the trackers had been reduced to -27 Celsius degrees. Though the thermal sensors themselves (Murata and Fenwal thermistors) are effective at these temperatures, the max1542 PLC (programmable logic controller) cards, interpreting the resistance of the thermal sensors into DC counts usable by the DCS (detector control system), are not designed for these temperatures in which the counts exceed their saturation and therefor had to be replaced. In my project I was in charge of handling the emplacement and calibration of the new PLC cards to the TOB (tracker outer barrel) control system.

  9. New maxillofacial infrared detection technologies

    Energy Technology Data Exchange (ETDEWEB)

    Reshetnikov, A. P.; Kopylov, M. V.; Nasyrov, M. R., E-mail: marat.1994@me.com; Fisher, E. L.; Chernova, L. V. [Izhevsk State Medical Academy, Izhevsk, Russia (426034, Izhevsk, Kommunarov street, 281) (Russian Federation); Soicher, E. M. [Moscow State University of Medicine and Dentistry named after A.I. Evdokimov of the Ministry of Health of the Russian Federation, Moscow, Russia, (127473, Moscow, Delegatskaya str., 20/1) (Russian Federation)

    2015-11-17

    At the dental clinic the infrared range radiation spectrum of tissues was used to study the dynamics of local temperature and structure of the skin, subcutaneous fat, and other tissues of the maxillofacial area in adult healthy volunteers and patients. In particular, we studied the dynamics of local temperature of mucous membranes of the mouth, teeth, and places in the mouth and dental structures in the norm and in various pathological conditions of the lips, gums, teeth, tongue, palate, and cheeks before, during and after chewing food, drinking water, medication, and inhalation of air. High safety and informational content of infrared thermography are prospective for the development of diagnostics in medicine. We have 3 new methods for infrared detection protected by patents in Russia.

  10. Mid-infrared Semiconductor Optoelectronics

    CERN Document Server

    Krier, Anthony

    2006-01-01

    The practical realisation of optoelectronic devices operating in the 2–10 µm (mid-infrared) wavelength range offers potential applications in a variety of areas from environmental gas monitoring around oil rigs and landfill sites to the detection of pharmaceuticals, particularly narcotics. In addition, an atmospheric transmission window exists between 3 µm and 5 µm that enables free-space optical communications, thermal imaging applications and the development of infrared measures for "homeland security". Consequently, the mid-infrared is very attractive for the development of sensitive optical sensor instrumentation. Unfortunately, the nature of the likely applications dictates stringent requirements in terms of laser operation, miniaturisation and cost that are difficult to meet. Many of the necessary improvements are linked to a better ability to fabricate and to understand the optoelectronic properties of suitable high-quality epitaxial materials and device structures. Substantial progress in these m...

  11. Infrared observations of extragalactic sources

    International Nuclear Information System (INIS)

    Kleinmann, D.E.

    1977-01-01

    The available balloon-borne and airborne infrared data on extragalactic sources, in particular M 82, NGC 1068 and NGC 253, is reviewed and discussed in the context of the extensive groundbased work. The data is examined for the clues they provide on the nature of the ultimate source of the energy radiated and on the mechanism(s) by which it is radiated. Since the discovery of unexpectedly powerful infrared radiation from extragalactic objects - a discovery now about 10 years old - the outstanding problems in this field have been to determine (1) the mechanism by which prodigious amounts of energy are released in the infrared, and (2) the nature of the underlying energy source. (Auth.)

  12. Germanium blocked impurity band far infrared detectors

    International Nuclear Information System (INIS)

    Rossington, C.S.

    1988-04-01

    The infrared portion of the electromagnetic spectrum has been of interest to scientist since the eighteenth century when Sir William Herschel discovered the infrared as he measured temperatures in the sun's spectrum and found that there was energy beyond the red. In the late nineteenth century, Thomas Edison established himself as the first infrared astronomer to look beyond the solar system when he observed the star Arcturus in the infrared. Significant advances in infrared technology and physics, long since Edison's time, have resulted in many scientific developments, such as the Infrared Astronomy Satellite (IRAS) which was launched in 1983, semiconductor infrared detectors for materials characterization, military equipment such as night-vision goggles and infrared surveillance equipment. It is now planned that cooled semiconductor infrared detectors will play a major role in the ''Star Wars'' nuclear defense scheme proposed by the Reagan administration

  13. Infrared sensing based sensitive skin

    Institute of Scientific and Technical Information of China (English)

    CAO Zheng-cai; FU Yi-li; WANG Shu-guo; JIN Bao

    2006-01-01

    Developed robotics sensitive skin is a modularized, flexible, mini-type array of infrared sensors with data processing capabilities, which can be used to cover the body of a robot. Depending on the infrared sensors and periphery processing circuit, robotics sensitive skin can in real-time provide existence and distance information about obstacles for robots within sensory areas. The methodology of designing sensitive skin and the algorithm of a mass of IR data fusion are presented. The experimental results show that the multi-joint robot with this sensitive skin can work autonomously in an unknown environment.

  14. Validation of Environmental Stress Index by Measuring Infrared Radiation as a Substitute for Solar Radiation in Indoor Workplaces

    Directory of Open Access Journals (Sweden)

    Peymaneh Habibi

    2016-09-01

    Full Text Available Background The exposure of individuals to heat at different jobs warrants the use of heat stress evaluation indices. Objectives The aim of this study was to validate environmental stress index using an infrared radiation (IR measurement instrument as a substitute for pyranometer in indoor workplaces. Methods This study was conducted on 2303 indoor workstations in different industries in Isfahan, Iran, during July, August, and September in 2012. The intensity of the Infrared Radiation (IR (w/m2 was measured at five-centimeter distances in six different directions, above, opposite, right, left, behind and below the globe thermometer. Then, the dry globe temperature (Ta, wet globe temperature (Tnw, globe temperature (Tg and relative humidity (RH were also simultaneously measured. The data were analyzed using correlation and regression by the SPSS18 software. Results The study results indicate that a high correlation (r = 0.96 exists between the environmental stress index (ESI and the values of wet bulb globe temperature (P < 0.01. According to the following equation, WBGT = 1.086 × ESI - 1.846, the environmental stress index is able to explain 91% (R2 = 0.91 of the WBGT index variations (P < 0.01. Conclusions Based on the results, to study heat stress in indoor workplaces when the WBGT measurement instrument is not available and also in short-term exposures (shorter than 30 minutes when measuring the wet bulb globe temperature shows a considerable error, it is possible to calculate the environmental stress index and accordingly to the WBGT index, by measuring the parameters of dry bulb temperature (Ta, relative humidity (RH, and infrared radiation intensity that can be easily measured in a short time.

  15. Advances in near-infrared measurements

    CERN Document Server

    Patonay, Gabor

    1991-01-01

    Advances in Near-Infrared Measurements, Volume 1 provides an overview of near-infrared spectroscopy. The book is comprised of six chapters that tackle various areas of near-infrared measurement. Chapter 1 discusses remote monitoring techniques in near-infrared spectroscopy with an emphasis on fiber optics. Chapter 2 covers the applications of fibers using Raman techniques, and Chapter 3 tackles the difficulties associated with near-infrared data analysis. The subsequent chapters present examples of the capabilities of near-infrared spectroscopy from various research groups. The text wi

  16. Infrared observations of planetary atmospheres

    International Nuclear Information System (INIS)

    Orton, G.S.; Baines, K.H.; Bergstralh, J.T.

    1988-01-01

    The goal of this research in to obtain infrared data on planetary atmospheres which provide information on several aspects of structure and composition. Observations include direct mission real-time support as well as baseline monitoring preceding mission encounters. Besides providing a broader information context for spacecraft experiment data analysis, observations will provide the quantitative data base required for designing optimum remote sensing sequences and evaluating competing science priorities. In the past year, thermal images of Jupiter and Saturn were made near their oppositions in order to monitor long-term changes in their atmospheres. Infrared images of the Jovian polar stratospheric hot spots were made with IUE observations of auroral emissions. An exploratory 5-micrometer spectrum of Uranus was reduced and accepted for publication. An analysis of time-variability of temperature and cloud properties of the Jovian atomsphere was made. Development of geometric reduction programs for imaging data was initiated for the sun workstation. Near-infrared imaging observations of Jupiter were reduced and a preliminary analysis of cloud properties made. The first images of the full disk of Jupiter with a near-infrared array camera were acquired. Narrow-band (10/cm) images of Jupiter and Saturn were obtained with acousto-optical filters

  17. The infrared astronomical mission AKARI

    NARCIS (Netherlands)

    Murakami, Hiroshi; Baba, Hajime; Barthel, Peter; Clements, David L.; Cohen, Martin; Doi, Yasuo; Enya, Keigo; Figueredo, Elysandra; Fujishiro, Naofumi; Fujiwara, Hideaki; Fujiwara, Mikio; Garcia-Lario, Pedro; Goto, Tomotsugu; Hasegawa, Sunao; Hibi, Yasunori; Hirao, Takanori; Hiromoto, Norihisa; Hong, Seung Soo; Imai, Koji; Ishigaki, Miho; Ishiguro, Masateru; Ishihara, Daisuke; Ita, Yoshifusa; Jeong, Woong-Seob; Jeong, Kyung Sook; Kaneda, Hidehiro; Kataza, Hirokazu; Kawada, Mitsunobu; Kawai, Toshihide; Kawamura, Akiko; Kessler, Martin F.; Kester, Do; Kii, Tsuneo; Kim, Dong Chan; Kim, Wjung; Kobayashi, Hisato; Koo, Bon Chul; Kwon, Suk Minn; Lee, Hyung Mok; Lorente, Rosario; Makiuti, Sin'itirou; Matsuhara, Hideo; Matsumoto, Toshio; Matsuo, Hiroshi; Matsuura, Shuji; Mueller, Thomas G.; Murakami, Noriko; Nagata, Hirohisa; Nakagawa, Takao; Naoi, Takahiro; Narita, Masanao; Noda, Manabu; Oh, Sang Hoon; Ohnishi, Akira; Ohyama, Youichi; Okada, Yoko; Okuda, Haruyuki; Oliver, Sebastian; Onaka, Takashi; Ootsubo, Takafumi; Oyabu, Shinki; Pak, Sojong; Park, Yong-Sun; Pearson, Chris P.; Rowan-Robinson, Michael; Saito, Toshinobu; Sakon, Itsuki; Salama, Alberto; Sato, Shinji; Savage, Richard S.; Serjeant, Stephen; Shibai, Hiroshi; Shirahata, Mai; Sohn, Jungjoo; Suzuki, Toyoaki; Takagi, Toshinobu; Takahashi, Hidenori; Tanabe, Toshihiko; Takeuchi, Tsutomu T.; Takita, Satoshi; Thomson, Matthew; Uemizu, Kazunori; Ueno, Munetaka; Usui, Fumihiko; Verdugo, Eva; Wada, Takehiko; Wang, Lingyu; Watabe, Toyoki; Watarai, Hidenori; White, Glenn J.; Yamamura, Issei; Yamauchi, Chisato; Yasuda, Akiko

    2007-01-01

    AKARI, the first Japanese satellite dedicated to infrared astronomy, was launched on 2006 February 21, and started observations in May of the same year. AKARI has a 68.5 cm cooled telescope, together with two focal-plane instruments, which survey the sky in six wavelength bands from mid- to

  18. Infrared spectroscopy with synchrotron radiation

    International Nuclear Information System (INIS)

    Lagarde, P.

    1978-01-01

    Storage rings are normally used as sources of radiation in the X-ray and the u.v. part of the spectrum. It is shown that, with a specially designed component, a storage ring like ACO at Orsay is a very powerful far-infrared source, whose advantages over classical wide band sources are reviewed. (author)

  19. The Aircraft Infrared Measurements Guide

    Science.gov (United States)

    1983-03-01

    the infrared portion of the electromagnetic spectrum, but should include measure- ments across that portion of the spectrum using optical /electro... optical tech- nology. Comments should be addressed to: Commander/Director Office of Missile Electronic Warfare US Army Electronic Warfare Laboratory ATTN...58 Spatial Radiometer ................................................ 58 Seekers ( Nonimaging

  20. Design and Analysis of a Multicolor Quantum Well Infrared Photodetector

    National Research Council Canada - National Science Library

    Alves, Fabio D. P

    2005-01-01

    .... These characteristics have been found in quantum well infrared photodetectors (QWIP). Driven by these applications, a QWIP photodetector capable of detecting simultaneously infrared emissions within near infrared (NIR...

  1. FAR-INFRARED EXTINCTION MAPPING OF INFRARED DARK CLOUDS

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Wanggi [Department of Astronomy, University of Florida, Gainesville, FL 32611 (United States); Tan, Jonathan C. [Departments of Astronomy and Physics, University of Florida, Gainesville, FL 32611 (United States)

    2014-01-10

    Progress in understanding star formation requires detailed observational constraints on the initial conditions, i.e., dense clumps and cores in giant molecular clouds that are on the verge of gravitational instability. Such structures have been studied by their extinction of near-infrared and, more recently, mid-infrared (MIR) background light. It has been somewhat more of a surprise to find that there are regions that appear as dark shadows at far-infrared (FIR) wavelengths as long as ∼100 μm! Here we develop analysis methods of FIR images from Spitzer-MIPS and Herschel-PACS that allow quantitative measurements of cloud mass surface density, Σ. The method builds on that developed for MIR extinction mapping by Butler and Tan, in particular involving a search for independently saturated, i.e., very opaque, regions that allow measurement of the foreground intensity. We focus on three massive starless core/clumps in the Infrared Dark Cloud (IRDC) G028.37+00.07, deriving mass surface density maps from 3.5 to 70 μm. A by-product of this analysis is the measurement of the spectral energy distribution of the diffuse foreground emission. The lower opacity at 70 μm allows us to probe to higher Σ values, up to ∼1 g cm{sup –2} in the densest parts of the core/clumps. Comparison of the Σ maps at different wavelengths constrains the shape of the MIR-FIR dust opacity law in IRDCs. We find that it is most consistent with the thick ice mantle models of Ossenkopf and Henning. There is tentative evidence for grain ice mantle growth as one goes from lower to higher Σ regions.

  2. FAR-INFRARED EXTINCTION MAPPING OF INFRARED DARK CLOUDS

    International Nuclear Information System (INIS)

    Lim, Wanggi; Tan, Jonathan C.

    2014-01-01

    Progress in understanding star formation requires detailed observational constraints on the initial conditions, i.e., dense clumps and cores in giant molecular clouds that are on the verge of gravitational instability. Such structures have been studied by their extinction of near-infrared and, more recently, mid-infrared (MIR) background light. It has been somewhat more of a surprise to find that there are regions that appear as dark shadows at far-infrared (FIR) wavelengths as long as ∼100 μm! Here we develop analysis methods of FIR images from Spitzer-MIPS and Herschel-PACS that allow quantitative measurements of cloud mass surface density, Σ. The method builds on that developed for MIR extinction mapping by Butler and Tan, in particular involving a search for independently saturated, i.e., very opaque, regions that allow measurement of the foreground intensity. We focus on three massive starless core/clumps in the Infrared Dark Cloud (IRDC) G028.37+00.07, deriving mass surface density maps from 3.5 to 70 μm. A by-product of this analysis is the measurement of the spectral energy distribution of the diffuse foreground emission. The lower opacity at 70 μm allows us to probe to higher Σ values, up to ∼1 g cm –2 in the densest parts of the core/clumps. Comparison of the Σ maps at different wavelengths constrains the shape of the MIR-FIR dust opacity law in IRDCs. We find that it is most consistent with the thick ice mantle models of Ossenkopf and Henning. There is tentative evidence for grain ice mantle growth as one goes from lower to higher Σ regions

  3. Atomic carbon in an infrared dark cloud

    NARCIS (Netherlands)

    Ossenkopf, Volker; Ormel, Chris W.; Simon, Robert; Sun, Kefeng; Stutzki, Jürgen

    2010-01-01

    Infrared dark clouds (IRDCs) are potential sites of massive star formation, dark in the near-infrared, but in many cases already with indications of active star-formation from far-infrared and submm observations. They are an ideal test bed to study the role of internal and external heating on the

  4. Microscopic dust in the infrared sky

    International Nuclear Information System (INIS)

    Leene, A.; Wesselius, P.

    1985-01-01

    After ten months of observation IRAS (InfraRed Astronomical Satellite) revealed for the first time an infrared sky map. One of its major discovery has been the display of new constituents in Universe: the infrared cirrus which are interstellar clouds constituted of microparticles abounding in carbon. Results and first hypothesis are presented in this article [fr

  5. Peeling mechanism of tomato under infrared heating

    Science.gov (United States)

    Critical behaviors of peeling tomatoes using infrared heat are thermally induced peel loosening and subsequent cracking. However, the mechanism of peel loosening and cracking due to infrared heating remains unclear. This study aimed at investigating the mechanism of peeling tomatoes under infrared h...

  6. SUPPLEMENTARY COMPARISON: Final report on supplementary comparison APMP-T-S3-03 of industrial platinum resistance and liquid in glass thermometers from -40 °C to 250 °C

    Science.gov (United States)

    Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.

    2007-01-01

    Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database

  7. Infrared observations of AE Aquarii

    Science.gov (United States)

    Tanzi, E. G.; Chincarini, G.; Tarenghi, M.

    1981-01-01

    Broadband infrared observations of the cataclysmic variable AE Aquarii are reported. The observations were obtained in the J, H, K and L filters with the InSb photometer attached to the 1-m telescope of the European Southern Observatory. The infrared energy distribution observed from 0.35 to 3.5 microns for phase 0.5 suggests a spectral type of K5 V for the secondary and a distance to the system of approximately 70 pc if an absolute magnitude of 7.3 is assumed. Monitoring of the flux at 2.2 microns reveals a variability with an amplitude of approximately 0.3 magnitude over one third of the orbital period, the nature of which is under investigation.

  8. The infrared spectrum of Jupiter

    Science.gov (United States)

    Ridgway, S. T.; Larson, H. P.; Fink, U.

    1976-01-01

    The principal characteristics of Jupiter's infrared spectrum are reviewed with emphasis on their significance for our understanding of the composition and temperature structure of the Jovian upper atmosphere. The spectral region from 1 to 40 microns divides naturally into three regimes: the reflecting region, thermal emission from below the cloud deck (5-micron hot spots), and thermal emission from above the clouds. Opaque parts of the Jovian atmosphere further subdivide these regions into windows, and each is discussed in the context of its past or potential contributions to our knowledge of the planet. Recent results are incorporated into a table of atmospheric composition and abundance which includes positively identified constituents as well as several which require verification. The limited available information about spatial variations of the infrared spectrum is presented

  9. Dual-band infrared camera

    Science.gov (United States)

    Vogel, H.; Schlemmer, H.

    2005-10-01

    Every year, numerous accidents happen on European roads due to bad visibility (fog, night, heavy rain). Similarly, the dramatic aviation accidents of year 2001 in Milan and Zurich have reminded us that aviation safety is equally affected by reduced visibility. A dual-band thermal imager was developed in order to raise human situation awareness under conditions of reduced visibility especially in the automotive and aeronautical context but also for all transportation or surveillance tasks. The chosen wavelength bands are the Short Wave Infrared SWIR and the Long Wave Infrared LWIR band which are less obscured by reduced visibility conditions than the visible band. Furthermore, our field tests clearly show that the two different spectral bands very often contain complementary information. Pyramidal fusion is used to integrate complementary and redundant features of the multi-spectral images into a fused image which can be displayed on a monitor to provide more and better information for the driver or pilot.

  10. Infrared slavery and quark confinement

    CERN Document Server

    Alabiso, C

    1976-01-01

    The question is considered of whether the so-called infrared slavery mechanism as, e.g., being manifest in non-Abelian gauge theories, necessarily confines quarks. Making a specific ansatz for the long- range forces, the Schwinger-Dyson equation is solved for the quark Green function. Besides having a confining solution, it appears that quarks may by-pass the long-range forces and be produced. (20 refs).

  11. Infrared slavery and quark confinement

    International Nuclear Information System (INIS)

    Alabiso, C.; Schierholz, G.

    1976-01-01

    The question of whether the so-called infrared slavery mechanism as, e.g., being manifest in non-Abelian gauge theories, necessarily confines quarks is posed. Making a specific ansatz for the long-range forces, the Schwinger-Dyson equation is solved for the quark Green function. Besides having a confining solution, it appears that quarks may by-pass the long-range forces and be produced. (Auth.)

  12. Infrared thermography in veterinary medicine

    International Nuclear Information System (INIS)

    Hudak, R.; Zivcak, J.; Sevcik, A.; Danko, J.

    2008-01-01

    The use of infrared thermography in veterinary medicine has been practiced since at least the 1960's, but it is only now, in approximately the last 5 years, that it has been viewed with a reasonably open mind in the veterinary community at large. One of the reasons is progress in sensors technology, which contributed for an outstanding improvement of the thermal imager parameters. Paper deals with veterinary thermography and with description of applications at the University of Veterinary Medicine in Kosice. (authors)

  13. HIGH-EFFICIENCY INFRARED RECEIVER

    Directory of Open Access Journals (Sweden)

    A. K. Esman

    2016-01-01

    Full Text Available Recent research and development show promising use of high-performance solid-state receivers of the electromagnetic radiation. These receivers are based on the low-barrier Schottky diodes. The approach to the design of the receivers on the basis of delta-doped low-barrier Schottky diodes with beam leads without bias is especially actively developing because for uncooled receivers of the microwave radiation these diodes have virtually no competition. The purpose of this work is to improve the main parameters and characteristics that determine the practical relevance of the receivers of mid-infrared electromagnetic radiation at the operating room temperature by modifying the electrodes configuration of the diode and optimizing the distance between them. Proposed original design solution of the integrated receiver of mid-infrared radiation on the basis of the low-barrier Schottky diodes with beam leads allows to effectively adjust its main parameters and characteristics. Simulation of the electromagnetic characteristics of the proposed receiver by using the software package HFSS with the basic algorithm of a finite element method which implemented to calculate the behavior of electromagnetic fields on an arbitrary geometry with a predetermined material properties have shown that when the inner parts of the electrodes of the low-barrier Schottky diode is performed in the concentric elliptical convex-concave shape, it can be reduce the reflection losses to -57.75 dB and the standing wave ratio to 1.003 while increasing the directivity up to 23 at a wavelength of 6.09 μm. At this time, the rounded radii of the inner parts of the anode and cathode electrodes are equal 212 nm and 318 nm respectively and the gap setting between them is 106 nm. These parameters will improve the efficiency of the developed infrared optical-promising and electronic equipment for various purposes intended for work in the mid-infrared wavelength range. 

  14. Diffuse Cosmic Infrared Background Radiation

    Science.gov (United States)

    Dwek, Eli

    2002-01-01

    The diffuse cosmic infrared background (CIB) consists of the cumulative radiant energy released in the processes of structure formation that have occurred since the decoupling of matter and radiation following the Big Bang. In this lecture I will review the observational data that provided the first detections and limits on the CIB, and the theoretical studies explaining the origin of this background. Finally, I will also discuss the relevance of this background to the universe as seen in high energy gamma-rays.

  15. Infrared spectral observation of stars

    International Nuclear Information System (INIS)

    Komaki, Kazuo; Kodaira, Keiichi; Tanaka, W.; Suemoto, Zenzaburo

    1976-01-01

    The atmosphere of fixed stars must be studied in a supplementary way with both observation and theory. In case of low-temperature stars, however, there are difficulties in both two aspects. Under the situation, the multi-color measurement of the near infrared region was performed with a balloon telescope BAT-1 (the aperture of 15 cm) on June 17 and 18, 1975. For the red supergiant αSco, the data of light measurement was able to be obtained. (mori, K.)

  16. Characteristics of radiation temperature and radiosity coefficient by means of infrared radiometer. Sekigai hoshakei ni yoru zairyo hyomen no hosha tokusei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Y; Kaminaga, F [Ibaraki University, Ibaraki (Japan). Faculty of Engineering; Ishii, T; Sato, K [Ibaraki University, Ibaraki (Japan); Kurokawa, T [NEC San-ei Instrumentsu Ltd., Tokyo (Japan)

    1991-12-25

    A radiation thermometer was applied to the measurement and analysis of radiation temperature of the material surface. In this paper, the characteristics of the radiation temperature and the radiosity coefficient of gray body materials are investigatied. An infrared radiometer was used, which detects radiation energy in the region between 8 and 13{mu}m of wavelength. This infared radiometer has a Hg-Cd-Te photon radiation sensor. The variation of emissivity was measured for the four kinds of non-metalic materials, i.e., graphite, carbon fiber composite, Si-SiC ceramic, and black paint spread on an aluminum plate. As a result, the relationship between material temperature and radiation energy was made clear. Furthermore, the space-dependent variation of the radiation temperature and the radiosity coefficient was derived from the two-dimensional CRT image of the infrared radiometer. Consequently, the emmisivity variation gave a maximum for the carbon fiber composite surface rich in irregularity, and decreased in the order of graphite, Si-SiC, and black paint. 7 refs., 15 figs.

  17. A simple mathematical procedure to estimate heat flux in machining using measured surface temperature with infrared laser

    Directory of Open Access Journals (Sweden)

    Hocine Mzad

    2015-09-01

    Full Text Available Several techniques have been developed over time for the measurement of heat and the temperatures generated in various manufacturing processes and tribological applications. Each technique has its own advantages and disadvantages. The appropriate technique for temperature measurement depends on the application under consideration as well as the available tools for measurement. This paper presents a procedure for a simple and accurate determination of the time-varying heat flux at the workpiece–tool interface of three different metals under known cutting conditions. A portable infrared thermometer is used for surface temperature measurements. A spline smoothing interpolation of the surface temperature history enables to determine the local heat flux produced during stock removal. The measured temperature is represented by a third-order spline approximation. Nonetheless, the accuracy of polynomial interpolation depends on how close are the interpolated points; an increase in degree cannot be used to increase the accuracy. Although the data analysis is relatively complicated, the computing time is very small.

  18. Analysis of temperature changes on three-phase synchronous generator using infrared: comparison between balanced and unbalanced load

    Science.gov (United States)

    Amien, S.; Yoga, W.; Fahmi, F.

    2018-02-01

    Synchronous generators are a major tool in an electrical energy generating systems, the load supplied by the generator is unbalanced. This paper discusses the effect of synchronous generator temperature on the condition of balanced load and unbalanced load, which will then be compared with the measurement result of both states of the generator. Unbalanced loads can be caused by various asymmetric disturbances in the power system and the failure of load forecasting studies so that the load distribution in each phase is not the same and causing the excessive heat of the generator. The method used in data collection was by using an infrared thermometer and resistance calculation method. The temperature comparison result between the resistive, inductive and capacitive loads in the highest temperature balance occured when the generator is loaded with a resistive load, where T = 31.9 ° C and t = 65 minutes. While in a state of unbalanced load the highest temperature occured when the generator is loaded with a capacitive load, where T = 40.1 ° C and t = 60 minutes. By understanding this behavior, we can maintain the generator for longer operation life.

  19. The infrared emissivities of soil and Artemisia tridentata and subsequent temperature corrections in a shrub-steppe ecosystem

    International Nuclear Information System (INIS)

    Hipps, L.E.

    1989-01-01

    The determination of plant and soil temperatures using remote sensing technology is examined in a shrub-steppe ecosystem. The emissivities of Artemisia tridentata L. shrubs and the soil surface were examined in such an ecosystem. The emissivity of A. tridentata plants was calculated to be 0.97, which is in the range of reported values for other green plants. The soil emissivity was 0.93. Temperature readings from an infrared thermometer (IRT) must be corrected for the emissivity value of the target and the reflected sky radiation. Although these two factors produce errors which are opposite in sign, they will not offset one another. An analysis is presented which quantifies the temperature error resulting from ignoring the corrections. The error is negligible only for emissivity values greater than 0.98. The error is proportional to temperature, and increases rapidly with decreases in emissivity. The true emissivities must be determined, and the above corrections must be calculated in order to obtain accurate temperatures in an ecosystem from remote sensing methods. (author)

  20. The infrared emissivities of soil and Artemisia tridentata and subsequent temperature corrections in a shrub-steppe ecosystem

    International Nuclear Information System (INIS)

    Hipps, L.E.

    1989-01-01

    The determination of plant and soil temperatures using remote sensing technology is examined in a shrub-steppe ecosystem. The emissivities of Artemisia tridentata L. shrubs and the soil surface were examined in such an ecosystem. The emissivity of A. tridentata plants was calculated to be 0.97, which is in the range of reported values for other green plants. The soil emissivity was 0.93. Temperature readings from an infrared thermometer (IRT) must be corrected for the emissivity value of the target and the reflected sky radiation. Although these two factors produce errors which are opposite in sign, they will not offset one another. An analysis is presented which quantifies the temperature error resulting from ignoring the corrections. The error is negligible only for emissivity values greater than 0.98. The error is proportional to temperature, and increases rapidly with decreases in emissivity. The true emissivities must be determined, and the above corrections must be calculated in order to obtain accurate temperatures in an ecosystem from remote sensing methods

  1. Towards the mid-infrared optical biopsy

    DEFF Research Database (Denmark)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir

    2016-01-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the mid-infrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy ('opsy' look at, bio the biology) in situ...... in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis...... of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security...

  2. Infrared observations of Seyfert galaxies and quasars

    International Nuclear Information System (INIS)

    Neugebauer, G.

    1978-01-01

    The infrared energy distributions of the Seyfert galaxies apparently contain three components: a galactic stellar component, a thermal component from heated dust, plus a nonthermal component. The appearance of the infrared energy distribution depends on which component dominates. There is also a correlation observed between the infrared energy distribution and the Khachikian Weedman class. Preliminary data on bright quasars are given. The infrared energy distributions generally increase into the infrared with a power law slope of approximately 1. In detail they differ from power laws with a significant fraction emitting most of their energy near 3μm. No differences in radio loud and radio quiet are obvious from the infrared energy distributions. The variability of the quasars in the infrared is generally correlated with the variability in the visible, although significant exceptions have been observed. (Auth.)

  3. Determination of mean molecular weights in organic reactor coolants. III. Differential cryoscopy with thermoelectric thermometer; Determinacion de masas moleculares medias en refrigerantes nucleares organicos. III-Crioscopia diferencial con termometro termoelectrico

    Energy Technology Data Exchange (ETDEWEB)

    Becerro, E; Carreira, M

    1968-07-01

    The solubility problems raised by some components of the polymeric residue of irradiated polyphenolic coolants, which make it necessary to operate with very small samples, have been solved by means of a differential cryoscopic technique using a thermoelectric thermometer (thermal) as sensitive element. The method is based on the direct measurement of the difference between the freezing points of the investigated solution and of a reference solution whose concentration may be changed at will. The change of {delta} V (mV) versus c(molal) is linear, the equivalent point being determined either analytically or graphically depending on the required accuracy. The method has been tested by measurements on pure polyphenyls, using diphenyl ether as solvent. It has been also applied to the main prospective coolants for the DON reactor. Working with 10{sup 2} molal solutions the accuracy is better than {+-} 2 per cent. (Author) 2 refs.

  4. Approximation of the thermometric characteristics of n- and p-GaAs thermodiodes in the 4.2-300 K temperature range and p-GaAs resistance thermometers in the 4.2-100 K temperature range

    International Nuclear Information System (INIS)

    Logvinenko, S.P.; Derbysheva, S.L.

    1978-01-01

    The investigation results are reported of various methods for approximating the calibration characteristics of technical resistance thermometers made from p-GaAs and of thermodiodes from n- p-GaAs. The following methods may by used for approximating thermometric characteristics and obtaining calibration tables: method of approximating function describing a physical model (P); method of power polynoms (PP); and the spline method (S). Studies of thermometric characteristics have been achieved in the 4.2-300 K temperature range for thermodiodes, and at 4.2-100 K for thermoresistances. The obtained data show that the use of the S and PP methods for describing monotonous thermometric characteristics of thermodiodes and thermoresistances is equivalent and leads to satisfactory results. Method S affords the best results for describing thermometric characteristics with specific features. The error in approximating thermometric characteristics by method S does not exceed 0.01 K

  5. CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    Energy Technology Data Exchange (ETDEWEB)

    Hill, K.D.; Steele, A.G. [National Research Council of Canada, Institute for National Measurement Standards, Ottawa, ON (Canada); Dedikov, Y.A.; Shkraba, V.T. [Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Moscow (Russian Federation)

    2005-04-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 {omega} capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L and N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. (authors)

  6. The effects of earphones and music on the temperature measured by infrared tympanic thermmeter: preliminary results.

    Science.gov (United States)

    Palese, Alvisa; Pasqualini, Davide

    2014-01-01

    The main aim of the study was to evaluate the effect on subjects' temperature measurement readings when using the infrared tympanic thermometer after correct earphone placement and use, with or without music transmission through the earphone. A comparative study design was adopted. A sample of 39 healthy people was randomly divided into three groups. Subjects in all groups used an earphone that had been correctly placed in the right ear only: Group 1: listened to heavy metal music through the earphone (13 participants); Group 2: listened to classical music through the earphone (13 participants); Group 3: no music or sound was transmitted through the earphone (13 participants). Average differences (CI 95%) and Pearson correlations for the temperature measured in the right ear, which was exposed to the different independent variables, and the left ear which was not exposed, were calculated at different times: (1) after 10 minutes compared to the baseline measurement; (2) after 30 minutes compared to the 10 minutes measurement; and (3) after 30 minutes compared to the baseline measurement. The inter-ear temperature correlation at the baseline was Pearson r .801 (p = .01). There was a significant decrease in the correlations between right and left ear temperatures in Group 1 and in Group 3 which was demonstrated after 10 minutes of earphone use, and reached critical values after 30 minutes of use in all groups. The average warmth in the right ear, as perceived by participants after 20 minutes, was reported. Using the Numerical Rating Score the average was 3.3 +/- 1.3 for Group 1, for Group 2 was 1.9 +/- 1.3 and for Group 3 was 3.3 +/- 1.2 (p = .05). Within the limitations of the study, which involved a limited number of healthy people the results show that it is best to not measure tympanic temperature in an ear that has very recently had an earphone in place.

  7. Infrared detectors for Earth observation

    Science.gov (United States)

    Barnes, K.; Davis, R. P.; Knowles, P.; Shorrocks, N.

    2016-05-01

    IASI (Infrared Atmospheric Sounding Interferometer), developed by CNES and launched since 2006 on the Metop satellites, is established as a major source of data for atmospheric science and weather prediction. The next generation - IASI NG - is a French national contribution to the Eumetsat Polar System Second Generation on board of the Metop second generation satellites and is under development by Airbus Defence and Space for CNES. The mission aim is to achieve twice the performance of the original IASI instrument in terms of sensitivity and spectral resolution. In turn, this places very demanding requirements on the infrared detectors for the new instrument. Selex ES in Southampton has been selected for the development of the infrared detector set for the IASI-NG instruments. The wide spectral range, 3.6 to 15.5 microns, is covered in four bands, each served by a dedicated detector design, with a common 4 x 4 array format of 1.3 mm square macropixels. Three of the bands up to 8.7 microns employ photovoltaic MCT (mercury cadmium telluride) technology and the very long wave band employs photoconductive MCT, in common with the approach taken between Airbus and Selex ES for the SEVIRI instrument on Second Generation Meteosat. For the photovoltaic detectors, the MCT crystal growth of heterojunction photodiodes is by the MOVPE technique (metal organic vapour phase epitaxy). Novel approaches have been taken to hardening the photovoltaic macropixels against localised crystal defects, and integrating transimpedance amplifiers for each macropixel into a full-custom silicon read out chip, which incorporates radiation hard design.

  8. Infrared sensitivity of unstable vacua

    International Nuclear Information System (INIS)

    Krotov, Dmitry; Polyakov, Alexander M.

    2011-01-01

    We discover that some unstable vacua have long memory. By that we mean that even in the theories containing only massive particles, there are correllators and expectation values which grow with time. We examine the cases of instabilities caused by the constant electric fields, expanding and contracting universes and, most importantly, the global de Sitter space. In the last case the interaction leads to a remarkable UV/IR mixing and to a large back reaction. This gives reasons to believe that the cosmological constant problem could be resolved by the infrared physics.

  9. Infrared radiation properties of anodized aluminum

    Energy Technology Data Exchange (ETDEWEB)

    Kohara, S. [Science Univ. of Tokyo, Noda, Chiba (Japan). Dept. of Materials Science and Technology; Niimi, Y. [Science Univ. of Tokyo, Noda, Chiba (Japan). Dept. of Materials Science and Technology

    1996-12-31

    The infrared radiation heating is an efficient and energy saving heating method. Ceramics have been used as an infrared radiant material, because the emissivity of metals is lower than that of ceramics. However, anodized aluminum could be used as the infrared radiant material since an aluminum oxide film is formed on the surface. In the present study, the infrared radiation properties of anodized aluminum have been investigated by determining the spectral emissivity curve. The spectral emissivity curve of anodized aluminum changed with the anodizing time. The spectral emissivity curve shifted to the higher level after anodizing for 10 min, but little changed afterwards. The infrared radiant material with high level spectral emissivity curve can be achieved by making an oxide film thicker than about 15 {mu}m on the surface of aluminum. Thus, anodized aluminum is applicable for the infrared radiation heating. (orig.)

  10. Space Infrared Telescope Facility (SIRTF) science instruments

    International Nuclear Information System (INIS)

    Ramos, R.; Hing, S.M.; Leidich, C.A.; Fazio, G.; Houck, J.R.

    1989-01-01

    Concepts of scientific instruments designed to perform infrared astronomical tasks such as imaging, photometry, and spectroscopy are discussed as part of the Space Infrared Telescope Facility (SIRTF) project under definition study at NASA/Ames Research Center. The instruments are: the multiband imaging photometer, the infrared array camera, and the infrared spectograph. SIRTF, a cryogenically cooled infrared telescope in the 1-meter range and wavelengths as short as 2.5 microns carrying multiple instruments with high sensitivity and low background performance, provides the capability to carry out basic astronomical investigations such as deep search for very distant protogalaxies, quasi-stellar objects, and missing mass; infrared emission from galaxies; star formation and the interstellar medium; and the composition and structure of the atmospheres of the outer planets in the solar sytem. 8 refs

  11. Novel Heterongineered Detectors for Multi-Color Infrared Sensing

    Science.gov (United States)

    2012-01-30

    a) Sequential but collocated two-color detection capabilities of type II InAsGaSb SLS detector based on an nBn design and (b) Simultaneous and...captions: Figure 1. Heterostructure Schematic of (a) PbIbN Design, (b) Dual Color Detector Design with flat band energy lineups . Figure 2. (a) Spectral

  12. Infra-red signature neutron detector

    Science.gov (United States)

    Bell, Zane William [Oak Ridge, TN; Boatner, Lynn Allen [Oak Ridge, TN

    2009-10-13

    A method of detecting an activator, the method including impinging with an activator a receptor material that includes a photoluminescent material that generates infrared radiation and generation a by-product of a nuclear reaction due to the activator impinging the receptor material. The method further includes generating light from the by-product via the Cherenkov effect, wherein the light activates the photoluminescent material so as to generate the infrared radiation. Identifying a characteristic of the activator based on the infrared radiation.

  13. Studies of the infrared source CRL 2688

    International Nuclear Information System (INIS)

    Ney, E.P.; Merrill, K.M.; Becklin, E.E.; Neugebauer, G.; Wynn-Williams, C.G.

    1975-01-01

    Infrared, optical, and radio observations are descirbed of a newly discovered galactic infrared source. Most of the radiation comes from 1/sup double-prime/./sub /5 diameter infrared source at a temperature of about 150 K, but some visible emission in the form of a symmetrical highly polarized reflection nebulosity is also seen. The object could represent either a very early or a very late stage in stellar evolution

  14. Transmission of infrared radiation through cylindrical waveguides

    International Nuclear Information System (INIS)

    Nucara, A.; Dore, P.; Calvani, P.; Cannavo', D.; Marcelli, A.

    1998-01-01

    Measurement of the transmittance of infrared radiation (v -1 ) through cylindrical waveguides are presented and discussed. The experimental results are compared with numerical simulations, obtained through conventional ray tracing programs. Finally, it' estimated the transmittance of a waveguide in the case of an infrared synchrotron radiation source. Are applied the results to the case of the DAΦNE collider, where a synchrotron radiation beamline for the far infrared is under construction

  15. Infrared multiphoton absorption and decomposition

    International Nuclear Information System (INIS)

    Evans, D.K.; McAlpine, R.D.

    1984-01-01

    The discovery of infrared laser induced multiphoton absorption (IRMPA) and decomposition (IRMPD) by Isenor and Richardson in 1971 generated a great deal of interest in these phenomena. This interest was increased with the discovery by Ambartzumian, Letokhov, Ryadbov and Chekalin that isotopically selective IRMPD was possible. One of the first speculations about these phenomena was that it might be possible to excite a particular mode of a molecule with the intense infrared laser beam and cause decomposition or chemical reaction by channels which do not predominate thermally, thus providing new synthetic routes for complex chemicals. The potential applications to isotope separation and novel chemistry stimulated efforts to understand the underlying physics and chemistry of these processes. At ICOMP I, in 1977 and at ICOMP II in 1980, several authors reviewed the current understandings of IRMPA and IRMPD as well as the particular aspect of isotope separation. There continues to be a great deal of effort into understanding IRMPA and IRMPD and we will briefly review some aspects of these efforts with particular emphasis on progress since ICOMP II. 31 references

  16. Infrared analysis of LMC superbubbles

    International Nuclear Information System (INIS)

    Verter, F.; Dwek, E.

    1990-01-01

    Researchers are analyzing three superbubbles in the Large Magellanic Cloud (LMC), cataloged by Meaburn (1980) as LMC-1, LMC-4 (a.k.a. Shapley Constellation III), and LMC-5. Superbubbles are the largest infrared sources in the disks of external galaxies. Their expansion requires multiple supernovae from successive generations of star formation. In LMC superbubbles, the grains swept up by shocks and winds represent an interstellar medium (ISM) whose abundances are quite different from the Galaxy. By applying the Dwek (1986) grain model, we can derive the composition and size spectrum of the grains. The inputs to this model are the dust emission in the four Infrared Astronomy Satellite (IRAS) bands and the interstellar radiation field (ISRF) that provides the heating. The first step in the project is to derive the ISRF for star-forming regions on the periphery of superbubbles. Researchers are doing this by combining observations at several wavelengths to determine the energy budget of the region. They will use a UV image to trace the ionizing stellar radiation that escapes, an H alpha image to trace the ionizing stellar radiation that is absorbed by gas, and the four IRAS images to trace the stellar radiation, both ionizing and non-ionizing, that is absorbed by dust. This multi-wavelength approach has the advantages that we do not have to assume the shape of the IMF or the extinction of the source

  17. New gonioscopy system using only infrared light.

    Science.gov (United States)

    Sugimoto, Kota; Ito, Kunio; Matsunaga, Koichi; Miura, Katsuya; Esaki, Koji; Uji, Yukitaka

    2005-08-01

    To describe an infrared gonioscopy system designed to observe the anterior chamber angle under natural mydriasis in a completely darkened room. An infrared light filter was used to modify the light source of the slit-lamp microscope. A television monitor connected to a CCD monochrome camera was used to indirectly observe the angle. Use of the infrared system enabled observation of the angle under natural mydriasis in a completely darkened room. Infrared gonioscopy is a useful procedure for the observation of the angle under natural mydriasis.

  18. An infrared view of high Tc superconductors

    International Nuclear Information System (INIS)

    Tanner, D.B.; Timusk, T.; McMaster Univ., Hamilton, ON

    1989-01-01

    Studies of the infrared properties of the high T c superconductors are reviewed, with particular emphasis on attempts to determine the energy gap by far infrared spectroscopy and on the properties of the strong absorption that occurs in the mid infrared. The authors argue that this mid-infrared absorption is a direct particle-hole excitation rather than a Holstein emission process. In addition, they conclude that although the energy gap is not easily observed, several recent experiments place it in the weak to moderate strong coupling range

  19. INFRARED GLOBAL GEOSTATIONARY COMPOSITE V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The National Center for Environmental Prediction/Aviation Weather Center Infrared Global Geostationary Composite data set contains global composite images from the...

  20. Radio continuum, far infrared and star formation

    International Nuclear Information System (INIS)

    Wielebinski, R.; Wunderlich, E.; Klein, U.; Hummel, E.

    1987-01-01

    A very tight correlation was found between the radio emission and the far infrared emission from galaxies. This has been found for various samples of galaxies and is explained in terms of recent star formation. The tight correlation would imply that the total radio emission is a good tracer of star formation. The correlation between the radio power at 5 GHz and the far infrared luminosity is shown. The galaxies are of various morphological types and were selected from the various IRAS circulars, hence the sample is an infrared selected sample. The far infrared luminosities were corrected for the dust temperature. This is significant because it decreases the dispersion in the correlation

  1. Technique of infrared synchrotron acceleration diagnostics

    International Nuclear Information System (INIS)

    Mal'tsev, A.A.; Mal'tsev, M.A.

    1997-01-01

    Techniques of measuring of current and geometric parameters and evaluating of energy parameters of the ring bunch of relativistic low-energy electrons have been presented. They have been based on using the synchrotron radiation effect in its infrared spectral part. Fast infrared detectors have provided radiation detection in the spectral range Δλ ≅ 0.3-45 μm. The descriptions of some data monitoring and measuring systems developed in JINR for the realization of techniques of the infrared synchrotron acceleration diagnostics have been given. Infrared optics elements specially developed have been used in these systems

  2. Spectrally-Tunable Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a SPECTRALLY-TUNABLE INFRARED CAMERA based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. This will build on...

  3. Handheld Longwave Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact handheld longwave infrared camera based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. Based on...

  4. Thermal Infrared and Visible to Near-Infrared Spectral Analysis of Chert and Amorphous Silica

    Science.gov (United States)

    McDowell, M. L.; Hamilton, V. E.; Cady, S. L.; Knauth, P.

    2009-03-01

    We look in detail at the thermal infrared and visible to near-infrared spectra of various forms of chert and amorphous silica and compare the spectral variations between samples with variations in physical and chemical characteristics.

  5. Infrared Line Intensities for Formaldehyde from Simultaneous Measurements in the Infrared and Far Infrared Spectral Ranges

    Science.gov (United States)

    Fissiaux, L.; Földes, T.; Tchana, F. Kwabia; Daumont, L.; Lepère, M.; Vander Auwera, J.

    2011-06-01

    Formaldehyde (H_2CO) is an important intermediate compound in the degradation of the volatile organic compounds (VOCs), including methane, in the terrestrial troposphere. Its observation using optical remote sensing in the infrared range relies on the 3.6 and 5.7 μm absorption bands. Band and individual line intensities have been reported in both ranges. With the present work, we aim to also derive infrared line intensities for formaldehyde, however relying on pure rotation line intensities and the known electric dipole moment to determine the particle density. Indeed, because formaldehyde polymerizes or degrades easily, the gas phase may contain polymerization or degradation products. Spectra of H_2CO diluted in 10 hPa of N_2 were therefore simultaneously recorded in the 20-60 Cm-1 and 3.6 μm ranges, respectively using a Bruker IFS125HR Fourier transform spectrometer and a tunable diode laser. see A. Perrin, D. Jacquemart, F. Kwabia Tchana, N. Lacome, J. Quant. Spectrosc. Radiat. Transfer 110 (2009) 700-716, and references therein

  6. Infrared spectroscopy of ionic clusters

    International Nuclear Information System (INIS)

    Price, J.M.

    1990-11-01

    This thesis describes new experiments wherein the infrared vibrational predissociation spectra of a number of mass-selected ionic cluster systems have been obtained and analyzed in the 2600 to 4000 cm -1 region. The species studied include: the hydrated hydronium ions, H 3 O + (H 2 O) 3 -10 , ammoniated ammonium ions, NH 4 + (NH 3 ) 1 -10 and cluster ions involving both water and ammonia around an ammonium ion core, (mixed clusters) NH 4 + (NH 3 ) n (H 2 O) m (n+m=4). In each case, the spectra reveal well resolved structures that can be assigned to transitions arising from the vibrational motions of both the ion core of the clusters and the surrounding neutral solvent molecules. 154 refs., 19 figs., 8 tabs

  7. Infrared spectroscopy of ionic clusters

    Energy Technology Data Exchange (ETDEWEB)

    Price, J.M. (California Univ., Berkeley, CA (USA). Dept. of Chemistry Lawrence Berkeley Lab., CA (USA))

    1990-11-01

    This thesis describes new experiments wherein the infrared vibrational predissociation spectra of a number of mass-selected ionic cluster systems have been obtained and analyzed in the 2600 to 4000 cm{sup {minus}1} region. The species studied include: the hydrated hydronium ions, H{sub 3}O{sup +} (H{sub 2}O){sub 3 {minus}10}, ammoniated ammonium ions, NH{sub 4}{sup +}(NH{sub 3}){sub 1 {minus}10} and cluster ions involving both water and ammonia around an ammonium ion core, (mixed clusters) NH{sub 4}{sup +}(NH{sub 3}){sub n}(H{sub 2}O){sub m} (n+m=4). In each case, the spectra reveal well resolved structures that can be assigned to transitions arising from the vibrational motions of both the ion core of the clusters and the surrounding neutral solvent molecules. 154 refs., 19 figs., 8 tabs.

  8. Capabilities of infrared weld monitor

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, P.G.; Keske, J.S.; Leong, K.H.; Kornecki, G.

    1997-11-01

    A non-obtrusive pre-aligned, solid-state device has been developed to monitor the primary infrared emissions during laser welding. The weld monitor output is a 100-1000 mV signal that depends on the beam power and weld characteristics. The DC level of this signal is related to weld penetration, while AC portions of the output can be correlated with surface irregularities and part misalignment or contamination. Changes in DC behavior are also noted for both full and deep penetration welds. Full penetration welds are signified by an abrupt reduction in the weld monitor output. Bead on plate welds were made on steel, aluminum, and magnesium with both a CW CO{sub 2} laser and a pulsed Nd:YAG laser to explore the relationships between the weld characteristics and the weld monitor output.

  9. Models for infrared atmospheric radiation

    Science.gov (United States)

    Tiwari, S. N.

    1976-01-01

    Line and band models for infrared spectral absorption are discussed. Radiative transmittance and integrated absorptance of Lorentz, Doppler, and voigt line profiles were compared for a range of parameters. It was found that, for the intermediate path lengths, the combined Lorentz-Doppler (Voigt) profile is essential in calculating the atmospheric transmittance. Narrow band model relations for absorptance were used to develop exact formulations for total absorption by four wide band models. Several continuous correlations for the absorption of a wide band model were compared with the numerical solutions of the wide band models. By employing the line-by-line and quasi-random band model formulations, computational procedures were developed for evaluating transmittance and upwelling atmospheric radiance. Homogeneous path transmittances were calculated for selected bands of CO, CO2, and N2O and compared with experimental measurements. The upwelling radiance and signal change in the wave number interval of the CO fundamental band were also calculated.

  10. [Infrared videonystagmography in vestibular diagnosis].

    Science.gov (United States)

    Frisina, A; Piazza, F; Quaranta, N

    2000-01-01

    Vestibular examination relied upon electronystagmography (ENG) for more than 50 years. This method is based on recording of nystagmus (Ny) without any possibility to see the ocular movements directly. More recently, infrared videonystagmography (VNG) entered the diagnostic protocol of vestibular disorders. VNG permits to record and visualize Ny, both in the darkness and with open eyes. Aim of the present study was to verify the possible advantages of VNG versus ENG for functional evaluation of the vestibular system in patients suffering from otoneurological disorders. To that purpose, VNG and ENG tracings were recorded in 12 patients. The preliminary results show that there are not significant differences in quantitative evaluation of Ny between the two methods. Anyhow, VNG has some technical and clinical advantages that make it the method of choice.

  11. The Cosmic Infrared Background Experiment

    Science.gov (United States)

    Bock, James; Battle, J.; Cooray, A.; Hristov, V.; Kawada, M.; Keating, B.; Lee, D.; Matsumoto, T.; Matsuura, S.; Nam, U.; Renbarger, T.; Sullivan, I.; Tsumura, K.; Wada, T.; Zemcov, M.

    2009-01-01

    We are developing the Cosmic Infrared Background ExpeRiment (CIBER) to search for signatures of first-light galaxy emission in the extragalactic background. The first generation of stars produce characteristic signatures in the near-infrared extragalactic background, including a redshifted Ly-cutoff feature and a characteristic fluctuation power spectrum, that may be detectable with a specialized instrument. CIBER consists of two wide-field cameras to measure the fluctuation power spectrum, and a low-resolution and a narrow-band spectrometer to measure the absolute background. The cameras will search for fluctuations on angular scales from 7 arcseconds to 2 degrees, where the first-light galaxy spatial power spectrum peaks. The cameras have the necessary combination of sensitivity, wide field of view, spatial resolution, and multiple bands to make a definitive measurement. CIBER will determine if the fluctuations reported by Spitzer arise from first-light galaxies. The cameras observe in a single wide field of view, eliminating systematic errors associated with mosaicing. Two bands are chosen to maximize the first-light signal contrast, at 1.6 um near the expected spectral maximum, and at 1.0 um; the combination is a powerful discriminant against fluctuations arising from local sources. We will observe regions of the sky surveyed by Spitzer and Akari. The low-resolution spectrometer will search for the redshifted Lyman cutoff feature in the 0.7 - 1.8 um spectral region. The narrow-band spectrometer will measure the absolute Zodiacal brightness using the scattered 854.2 nm Ca II Fraunhofer line. The spectrometers will test if reports of a diffuse extragalactic background in the 1 - 2 um band continues into the optical, or is caused by an under estimation of the Zodiacal foreground. We report performance of the assembled and tested instrument as we prepare for a first sounding rocket flight in early 2009. CIBER is funded by the NASA/APRA sub-orbital program.

  12. Uncooled infrared photodetectors in Poland

    Science.gov (United States)

    Piotrowski, J.; Piotrowski, A.

    2006-03-01

    The history and present status of the middle and long wavelength Hg1-xCdxTe infrared detectors in Poland are reviewed. Research and development efforts in Poland were concentrated mostly on uncooled market niche. Technology of the infrared photodetectors has been developed by several research groups. The devices are based on mercury-based variable band gap semiconductor alloys. Modified isothermal vapour phase epitaxy (ISOVPE) has been used for many years for research and commercial fabrication of photoconductive, photoelectromagnetic and other devices. Bulk growth and liquid phase epitaxy was also used. At present, the fabrication of IR devices relies on low temperature epitaxial technique, namely metalorganic vapour phase deposition (MOCVD), frequently in combination with the ISOVPE. Photoconductive and photoelectromagnetic detectors are still in production. The devices are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, the PV devices could offer high performance and very fast response. At present, the uncooled long wavelength devices of conventional design suffer from two issues; namely low quantum efficiency and very low junction resistance. It makes them useless for practical applications. The problems have been solved with advanced 3D band gap engineered architecture, multiple cell heterojunction devices connected in series, monolithic integration of the detectors with microoptics and other improvements. Present fabrication program includes devices which are optimized for operation at any wavelength within a wide spectral range 1-15 μm and 200-300 K temperature range. Special solutions have been applied to improve speed of response. Some devices show picoseconds range response time. The devices have found numerous civilian and military applications.

  13. Infrared signatures for remote sensing

    International Nuclear Information System (INIS)

    McDowell, R.S.; Sharpe, S.W.; Kelly, J.F.

    1994-04-01

    PNL's capabilities for infrared and near-infrared spectroscopy include tunable-diode-laser (TDL) systems covering 300--3,000 cm -1 at 2 laser. PNL also has a beam expansion source with a 12-cm slit, which provides a 3-m effective path for gases at ∼10 K, giving a Doppler width of typically 10 MHz; and long-path static gas cells (to 100 m). In applying this equipment to signatures work, the authors emphasize the importance of high spectral resolution for detecting and identifying atmospheric interferences; for identifying the optimum analytical frequencies; for deriving, by spectroscopic analysis, the molecular parameters needed for modeling; and for obtaining data on species and/or bands that are not in existing databases. As an example of such spectroscopy, the authors have assigned and analyzed the C-Cl stretching region of CCl 4 at 770--800 cm -1 . This is an important potential signature species whose IR absorption has remained puzzling because of the natural isotopic mix, extensive hot-band structure, and a Fermi resonance involving a nearby combination band. Instrument development projects include the IR sniffer, a small high-sensitivity, high-discrimination (Doppler-limited) device for fence-line or downwind monitoring that is effective even in regions of atmospheric absorption; preliminary work has achieved sensitivities at the low-ppb level. Other work covers trace species detection with TDLs, and FM-modulated CO 2 laser LIDAR. The authors are planning a field experiment to interrogate the Hanford tank farm for signature species from Rattlesnake Mountain, a standoff of ca. 15 km, to be accompanied by simultaneous ground-truthing at the tanks

  14. Fourier Transform Infrared Spectroscopy Part III. Applications.

    Science.gov (United States)

    Perkins, W. D.

    1987-01-01

    Discusses the use of the FT-IR spectrometer in analyses that were previously avoided. Examines some of the applications of this spectroscopy with aqueous solutions, circular internal reflection, samples with low transmission, diffuse reflectance, infrared emission, and the infrared microscope. (TW)

  15. Infrared ship signature analysis and optimisation

    NARCIS (Netherlands)

    Neele, F.P.

    2005-01-01

    The last decade has seen an increase in the awareness of the infrared signature of naval ships. New ship designs show that infrared signature reduction measures are being incorporated, such as exhaust gas cooling systems, relocation of the exhausts and surface cooling systems. Hull and

  16. INFRARED AND RAMAN SPECTROSCOPIC STUDY OF ION ...

    African Journals Online (AJOL)

    Infrared and Raman spectroscopy techniques have been used to study the ionic interactions of strontium(II) and barium(II) with thiocyanate ion in liquid ammonia. A number of bands were observed in both n (CN) and n (CS) regions of infrared and Raman spectra and these were assigned to 1:1 contact ion pair, ...

  17. A flexible infrared sensor for tissue oximetry

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Thyssen, Anders; Engholm, Mathias

    2013-01-01

    We present a flexible infrared sensor for use in tissue oximetry with the aim of treating prematurely born infants. The sensor will detect the oxygen saturation in brain tissue through near infrared spectroscopy. The sensor itself consists of several individual silicon photo detectors fully...

  18. Near infrared detection of ammonium minerals.

    Science.gov (United States)

    Krohn, M.D.; Altaner, S.P.

    1987-01-01

    Diagnostic near-infrared spectral features have been identified for minerals with ammonium (NH4+) bound in the crystal structure. Near-infrared detection of NH4-bearing minerals may provide useful information for prospecting for certain ore deposits and may provide a better understanding of the nitrogen cycle within geologic environments.-from Authors

  19. The DENIS & 2MASS Near Infrared Surveys

    OpenAIRE

    Mamon, Gary

    1996-01-01

    The DENIS and 2MASS near infrared surveys are presented. Their applications in extragalactic astronomy and cosmology are listed. The prospects for a rapid spectroscopic followup survey of a near infrared selected sample of nearly $10^5$ galaxies are illustrated with Monte-Carlo simulations.

  20. Infrared Radiative Properties of Food Materials

    Science.gov (United States)

    Precisely, infrared radiation is electromagnetic radiation whose wavelength is longer than that of visible light, but shorter than that of terahertz radiation and microwaves. The infrared portion of the electromagnetic spectrum spans roughly three orders of magnitude (750 nm to 100 µm) and has been...

  1. Kinetics of infrared stimulated luminescence from feldspars

    DEFF Research Database (Denmark)

    Jain, Mayank; Sohbati, Reza; Guralnik, Benny

    2015-01-01

    thermal and optical, of the infrared stimulated luminescence signal from feldspar. Based on the application of this model, it is concluded that different infra-red stimulated luminescence emissions (UV, blue, yellow and far-red) follow the same kinetics, and, therefore, involve participation of the same...

  2. Experimental evidence of infrared scintillation in crystals

    CERN Document Server

    Belogurov, S; Carugno, Giovanni; Conti, E; Iannuzzi, D; Meneguzzo, Anna Teresa

    2000-01-01

    We present experimental results on infrared emission induced by protons in some solid-state samples. Infrared scintillation occurs in many crystals, with different yield values and time-response behaviours. A rough measurement of the emission wavelength of CsI(Tl) is also reported.

  3. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    Science.gov (United States)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  4. Application of infrared to biomedical sciences

    CERN Document Server

    Etehadtavakol, Mahnaz

    2017-01-01

    The book covers the latest updates in the application of infrared to biomedical sciences, a non-invasive, contactless, safe and easy approach imaging of skin and tissue temperatures. Its diagnostic procedure allows practitioners to identify the locations of abnormal chemical and blood vessel activity such as angiogenesis in body tissue. Its non-invasive approach works by applying the technology of the infrared camera and state-of-the-art software, where high-resolution digital infrared imaging technology benefits highly from enhanced image production, standardized image interpretation protocols, computerized comparison and storage, and sophisticated image enhancement and analysis. The book contains contributions from global prominent scientists in the area of infrared applications in biomedical studies. The target audience includes academics, practitioners, clinicians and students working in the area of infrared imaging in biomedicine.

  5. FY 2006 Infrared Photonics Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Allen, Paul J.; Bernacki, Bruce E.; Ho, Nicolas; Krishnaswami, Kannan; Qiao, Hong (Amy); Schultz, John F.

    2006-12-28

    Research done by the Infrared Photonics team at Pacific Northwest National Laboratory (PNNL) is focused on developing miniaturized integrated optics and optical fiber processing methods for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications by exploiting the unique optical and material properties of chalcogenide glass. PNNL has developed thin-film deposition capabilities, direct laser writing techniques, infrared photonic device demonstration, holographic optical element design and fabrication, photonic device modeling, and advanced optical metrology—all specific to chalcogenide glass. Chalcogenide infrared photonics provides a pathway to quantum cascade laser (QCL) transmitter miniaturization. The high output power, small size, and superb stability and modulation characteristics of QCLs make them amenable for integration as transmitters into ultra-sensitive, ultra-selective point sampling and remote short-range chemical sensors that are particularly useful for nuclear nonproliferation missions.

  6. Observation of galactic far-infrared ray

    International Nuclear Information System (INIS)

    Maihara, Toshinori; Oda, Naoki; Okuda, Haruyuki; Sugiyama, Takuya; Sakai, Kiyomi.

    1978-01-01

    Galactic far-infrared was observed to study the spatial distribution of interstellar dust. Far-infrared is emitted by interstellar dust distributing throughout the galactic plane. The observation of far-infrared is very important to study the overall structure of the galaxy, that is the structure of the galactic arm and gas distribution. The balloon experiment was conducted on May 25, 1978. The detector was a germanium bolometer cooled by liquid helium. The size of the detector is 1.6 mm in diameter. The geometrical factor was 4 x 10 3 cm 2 sr. The result showed that the longitude distribution of far-infrared at 150 μm correlated with H 166 α recombination line. This indicates that the observed far-infrared is emitted by interstellar dust heated by photons of Lyman continuum. (Yoshimori, M.)

  7. Infrared reflection nebulae in Orion Molecular Cloud

    International Nuclear Information System (INIS)

    Pendleton, Y.; Werner, M.W.; Capps, R.; Lester, D.; Hawaii Univ., Honolulu; Texas Univ., Austin)

    1986-01-01

    New observations of Orion Molecular Cloud 2 have been made from 1 to 100 microns using the NASA Infrared Telescope Facility and the Kuiper Airborne Observatory. An extensive program of polarimetry, photometry, and spectrophotometry has shown that the extended emission regions associated with two of the previously known near-infrared sources, IRS 1 and IRS 4, are infrared reflection nebulae, and that the compact sources IRS 1 and IRS 4 are the main luminosity sources in the cloud. The constraints from the far-infrared observations and an analysis of the scattered light from the IRS 1 nebula show that OMC-2/IRS 1 can be characterized by L of 500 solar luminosities or less and T of roughly 1000 K. The near-infrared albedo of the grains in the IRS 1 nebula is greater than 0.08. 27 references

  8. FY 2005 Infrared Photonics Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Allen, Paul J.; Ho, Nicolas; Krishnaswami, Kannan; Johnson, Bradley R.; Sundaram, S. K.; Riley, Bradley M.; Martinez, James E.; Qiao, Hong (Amy); Schultz, John F.

    2005-12-01

    Research done by the Infrared Photonics team at Pacific Northwest National Laboratory (PNNL) is focused on developing miniaturized integrated optics for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications by exploiting the unique optical and material properties of chalcogenide glass. PNNL has developed thin-film deposition capabilities, direct laser writing techniques, infrared photonic device demonstration, holographic optical element design and fabrication, photonic device modeling, and advanced optical metrology—all specific to chalcogenide glass. Chalcogenide infrared photonics provides a pathway to quantum cascade laser (QCL) transmitter miniaturization. QCLs provide a viable infrared laser source for a new class of laser transmitters capable of meeting the performance requirements for a variety of national security sensing applications. The high output power, small size, and superb stability and modulation characteristics of QCLs make them amenable for integration as transmitters into ultra-sensitive, ultra-selective point sampling and remote short-range chemical sensors that are particularly useful for nuclear nonproliferation missions. During FY 2005, PNNL’s Infrared Photonics research team made measurable progress exploiting the extraordinary optical and material properties of chalcogenide glass to develop miniaturized integrated optics for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications. We investigated sulfur purification methods that will eventually lead to routine production of optical quality chalcogenide glass. We also discovered a glass degradation phenomenon and our investigation uncovered the underlying surface chemistry mechanism and developed mitigation actions. Key research was performed to understand and control the photomodification properties. This research was then used to demonstrate several essential infrared photonic devices, including LWIR single-mode waveguide devices and

  9. A Novel Infrared Gas Monitor

    Science.gov (United States)

    Wang, Yingding; Zhong, Hongjie

    2000-03-01

    In the paper a novel non-dispersive infrared(IR) gas monitor is described.It is based on the principle that certain gases absorb IR radiation at specific(and often unique) wavelengths.Conventional devices typically include several primary components:a broadband source, usually an incandescent filament,a rotating chopper shutter,a narrow-band filter,a sample tube and a detector. We have developed a number of IR light emitting diodes(LED) having narrow optical bandwidths and which can be intensity modulated by electrical means,for example InAsSbP(4.2 micron)LED.The IR LED can thus replace the thermal source,narrow-band filter and chopper assembly of the conventional IR gas monitor,yielding a solid state,low- powered,compact and almost maintenance-free instrument with high sensitivity and stability and which free of the effects of mechanical vibration too. The detector used in the IR gas monitor is the solid-state detector,such as PbS,PbSe, InSb,HgCdTe,TGS,LT and PZT detector etc. The different configuration of the IR gas monitor is designed.For example,two-path version for measuring methane concentration by monitoring the 3.31 micron absorption band,it can eliminate the interference effects,such as to compensate for LED intensity changes caused by power and temperature variations,and for signal fluctuations due to changes in detector bias. we also have designed portable single-beam version without the sample tube.Its most primary advantage is very cheap(about cost USD 30 ).It measures carbon dioxide concentration by monitoring the 4.25 micron absorption band.Thought its precisions is low,it is used to control carbon dioxide concentration in the air in the green houses and plastic houses(there are about twenty millon one in the China).Because more carbon dioxide will increase the quanity of vegetable and flower production to a greatextent. It also is used in medical,sanitary and antiepidemic applications,such as hospital, store,hotel,cabin and ballroom etc. Key words:infrared

  10. Infrared spectroscopy by use of synchrotron radiation

    International Nuclear Information System (INIS)

    Nanba, Takao

    1991-01-01

    During five years since the author wrote the paper on the utilization of synchrotron radiation in long wavelength region, it seems to be recognized that in synchrotron radiation, the light from infrared to milli wave can be utilized, and is considerably useful. Recently the research on coherent synchrotron radiation in this region using electron linac has been developed by Tohoku University group, and the high capability of synchrotron radiation as light source is verified. This paper is the report on the infrared spectroscopic research using incoherent synchrotron radiation obtained from the deflection electromagnet part of electron storage rings. Synchrotron radiation is high luminance white light source including from X-ray to micro wave. The example of research that the author carried out at UVSOR is reported, and the perspective in near future is mentioned. Synchrotron radiation as the light source for infrared spectroscopy, the intensity and dimensions of the light source, far infrared region and mid infrared region, far infrared high pressure spectroscopic experiment, and the heightening of luminance of synchrotron radiation as infrared light source are described. (K.I.)

  11. Infrared and Raman spectroscopy: principles and spectral interpretation

    National Research Council Canada - National Science Library

    Larkin, Peter

    2011-01-01

    "Infrared and Raman Spectroscopy: Principles and Spectral Interpretation explains the background, core principles and tests the readers understanding of the important techniques of Infrared and Raman Spectroscopy...

  12. Mid infrared lasers for remote sensing applications

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Brian M., E-mail: brian.m.walsh@nasa.gov [NASA Langley Research Center, Hampton, VA 23681 (United States); Lee, Hyung R. [National Institute of Aerospace, Hampton, VA 23666 (United States); Barnes, Norman P. [Science Systems and Applications, Inc., Hampton, VA 23666 (United States)

    2016-01-15

    To accurately measure the concentrations of atmospheric gasses, especially the gasses with low concentrations, strong absorption features must be accessed. Each molecular species or constituent has characteristic mid-infrared absorption features by which either column content or range resolved concentrations can be measured. Because of these characteristic absorption features the mid infrared spectral region is known as the fingerprint region. However, as noted by the Decadal Survey, mid-infrared solid-state lasers needed for DIAL systems are not available. The primary reason is associated with short upper laser level lifetimes of mid infrared transitions. Energy gaps between the energy levels that produce mid-infrared laser transitions are small, promoting rapid nonradiative quenching. Nonradiative quenching is a multiphonon process, the more phonons needed, the smaller the effect. More low energy phonons are required to span an energy gap than high energy phonons. Thus, low energy phonon materials have less nonradiative quenching compared to high energy phonon materials. Common laser materials, such as oxides like YAG, are high phonon energy materials, while fluorides, chlorides and bromides are low phonon materials. Work at NASA Langley is focused on a systematic search for novel lanthanide-doped mid-infrared solid-state lasers using both quantum mechanical models (theoretical) and spectroscopy (experimental) techniques. Only the best candidates are chosen for laser studies. The capabilities of modeling materials, experimental challenges, material properties, spectroscopy, and prospects for lanthanide-doped mid-infrared solid-state laser devices will be presented. - Highlights: • We discuss mid infrared lasers and laser materials. • We discuss applications to remote sensing. • We survey the lanthanide ions in low phonon materials for potential. • We present examples of praseodymium mid infrared spectroscopy and laser design.

  13. Infrared microspectroscopy with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Carr, G.L.; Williams, G.P. [Brookhaven National Lab., Upton, NY (United States). National Synchrotron Light Source

    1997-09-01

    Infrared microspectroscopy with a high brightness synchrotron source can achieve a spatial resolution approaching the diffraction limit. However, in order to realize this intrinsic source brightness at the specimen location, some care must be taken in designing the optical system. Also, when operating in diffraction limited conditions, the effective spatial resolution is no longer controlled by the apertures typically used for a conventional (geometrically defined) measurement. Instead, the spatial resolution depends on the wavelength of light and the effective apertures of the microscope`s Schwarzchild objectives. The authors have modeled the optical system from the synchrotron source up to the sample location and determined the diffraction-limited spatial distribution of light. Effects due to the dependence of the synchrotron source`s numerical aperture on wavelength, as well as the difference between transmission and reflection measurement modes, are also addressed. Lastly, they examine the benefits (when using a high brightness source) of an extrinsic germanium photoconductive detector with cone optics as a replacement for the standard MCT detector.

  14. Quartz substrate infrared photonic crystal

    Science.gov (United States)

    Ghadiri, Khosrow; Rejeb, Jalel; Vitchev, Vladimir N.

    2003-01-01

    This paper presents the fabrication of a planar photonic crystal (p2c) made of a square array of dielectric rods embedded in air, operating in the infrared spectrum. A quartz substrate is employed instead of the commonly used silicon or column III-V substrate. Our square structure has a normalized cylinder radius-to-pitch ratio of r/a = 0.248 and dielectric material contrast ɛr of 4.5. We choose a Z-cut synthetic quartz for its cut (geometry), and etching properties. Then a particular Z-axis etching process is employed in order to ensure the sharp-edged verticality of the rods and fast etching speed. We also present the computer simulations that allowed the establishment of the photonic band gaps (PBG) of our photonic crystal, as well as the actual measurements. An experimental measurement have been carried out and compared with different simulations. It was found that experimental results are in good agreement with different simulation results. Finally, a frequency selective device for optical communication based on the introduction of impurity sites in the photonic crystal is presented. With our proposed structure Optical System on a Chip (OsoC) with micro-cavity based active devices such as lasers, diodes, modulators, couplers, frequency selective emitters, add-drop filters, detectors, mux/demuxes and polarizers connected by passive waveguide links can be realized.

  15. Mid infrared MEMS FTIR spectrometer

    Science.gov (United States)

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  16. Infrared thermography quantitative image processing

    Science.gov (United States)

    Skouroliakou, A.; Kalatzis, I.; Kalyvas, N.; Grivas, TB

    2017-11-01

    Infrared thermography is an imaging technique that has the ability to provide a map of temperature distribution of an object’s surface. It is considered for a wide range of applications in medicine as well as in non-destructive testing procedures. One of its promising medical applications is in orthopaedics and diseases of the musculoskeletal system where temperature distribution of the body’s surface can contribute to the diagnosis and follow up of certain disorders. Although the thermographic image can give a fairly good visual estimation of distribution homogeneity and temperature pattern differences between two symmetric body parts, it is important to extract a quantitative measurement characterising temperature. Certain approaches use temperature of enantiomorphic anatomical points, or parameters extracted from a Region of Interest (ROI). A number of indices have been developed by researchers to that end. In this study a quantitative approach in thermographic image processing is attempted based on extracting different indices for symmetric ROIs on thermograms of the lower back area of scoliotic patients. The indices are based on first order statistical parameters describing temperature distribution. Analysis and comparison of these indices result in evaluating the temperature distribution pattern of the back trunk expected in healthy, regarding spinal problems, subjects.

  17. Infrared studies of symbiotic stars

    International Nuclear Information System (INIS)

    Allen, D.A.

    1982-01-01

    Infrared photometry and spectroscopy of symbiotic stars is reviewed. It is shown that at wavelengths beyond 1 μm these systems are generally dominated by the cool star's photosphere and, indeed, are indistinguishable from ordinary late-type giants. About 25% of symbiotic stars exhibit additional emission due to circumstellar dust. Most of the dusty systems probably involve Mira variables, the dust forming in the atmospheres of the Miras. In a few cases the dust is much cooler and the cool component hotter; the dust must then form in distant gas shielded from the hot component, perhaps by an accretion disk. Spectroscopy at 2 μm can be used to spectral type the cool components, even in the presence of some dust emission. Distances may thereby be estimated, though with some uncertainty. Spectroscopy at longer wavelengths reveals information about the dust itself. In most cases this dust appears to include silicate grains, which form in the oxygen-rich envelope of an M star. In the case of HD 33036, however, different emission features are found which suggest a carbon-rich environment. (Auth.)

  18. Infrared Constraint on Ultraviolet Theories

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Yuhsin [Cornell Univ., Ithaca, NY (United States)

    2012-08-01

    While our current paradigm of particle physics, the Standard Model (SM), has been extremely successful at explaining experiments, it is theoretically incomplete and must be embedded into a larger framework. In this thesis, we review the main motivations for theories beyond the SM (BSM) and the ways such theories can be constrained using low energy physics. The hierarchy problem, neutrino mass and the existence of dark matter (DM) are the main reasons why the SM is incomplete . Two of the most plausible theories that may solve the hierarchy problem are the Randall-Sundrum (RS) models and supersymmetry (SUSY). RS models usually suffer from strong flavor constraints, while SUSY models produce extra degrees of freedom that need to be hidden from current experiments. To show the importance of infrared (IR) physics constraints, we discuss the flavor bounds on the anarchic RS model in both the lepton and quark sectors. For SUSY models, we discuss the difficulties in obtaining a phenomenologically allowed gaugino mass, its relation to R-symmetry breaking, and how to build a model that avoids this problem. For the neutrino mass problem, we discuss the idea of generating small neutrino masses using compositeness. By requiring successful leptogenesis and the existence of warm dark matter (WDM), we can set various constraints on the hidden composite sector. Finally, to give an example of model independent bounds from collider experiments, we show how to constrain the DM–SM particle interactions using collider results with an effective coupling description.

  19. Submonolayer Quantum Dot Infrared Photodetector

    Science.gov (United States)

    Ting, David Z.; Bandara, Sumith V.; Gunapala, Sarath D.; Chang, Yia-Chang

    2010-01-01

    A method has been developed for inserting submonolayer (SML) quantum dots (QDs) or SML QD stacks, instead of conventional Stranski-Krastanov (S-K) QDs, into the active region of intersubband photodetectors. A typical configuration would be InAs SML QDs embedded in thin layers of GaAs, surrounded by AlGaAs barriers. Here, the GaAs and the AlGaAs have nearly the same lattice constant, while InAs has a larger lattice constant. In QD infrared photodetector, the important quantization directions are in the plane perpendicular to the normal incidence radiation. In-plane quantization is what enables the absorption of normal incidence radiation. The height of the S-K QD controls the positions of the quantized energy levels, but is not critically important to the desired normal incidence absorption properties. The SML QD or SML QD stack configurations give more control of the structure grown, retains normal incidence absorption properties, and decreases the strain build-up to allow thicker active layers for higher quantum efficiency.

  20. An infrared free-electron laser for the Chemical Dynamics Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (comp.)

    1992-04-01

    This document describes a free-electron laser (FEL) proposed as part of the Chemical Dynamics Research Laboratory (CDRL), a user facility that also incorporates several advanced lasers of conventional design and two beamlines for the ALS. The FEL itself addresses the needs of the chemical sciences community for a high-brightness, tunable source covering a broad region of the infrared spectrum -- from 3 to 50 {mu}m. All of these sources, together with a variety of sophisticated experimental stations, will be housed in a new building to be located adjacent to the ALS. The radiation sources can be synchronized to permit powerful two-color, pump-probe experiments that will further our fundamental understanding of chemical dynamics at the molecular level, especially those aspects relevant to practical issues in combustion chemistry. The technical approach adopted in this design makes use of superconducting radiofrequency (SCRF) accelerating structures. The primary motivation for adopting this approach was to meet the user requirement for wavelength stability equal to one part in 10{sup 4}. Previous studies concluded that a wavelength stability of only one part in 10{sup 3} could be achieved with currently available room-temperature technology. In addition, the superconducting design operates in a continuous-wave (cw) mode and hence offers considerably higher average optical output power. It also allows for various pulse-gating configurations that will permit simultaneous multiuser operations. A summary of the comparative performance attainable with room-temperature and superconducting designs is given. The FEL described in this report provides a continuous train of 30-ps micropulses, with 100{mu}J of optical energy per micropulse, at a repetition rate of 6.1 MHz. The device can also deliver pulses at a cw repetition rate of 12.2 MHz, with a peak power of 50 {mu}J per micropulse. 70 ref.