WorldWideScience

Sample records for tungstate crystal calorimeter

  1. Performance of an electromagnetic calorimeter with lead-tungstate crystals

    International Nuclear Information System (INIS)

    Kohara, R.; Sugitate, T.; Sugita, N.; Tsuchimoto, Y.; Toyoda, D.; Homma, K.; Yamazaki, H.

    2003-01-01

    The performance of an electromagnetic calorimeter with lead-tungstate (PWO) crystals was tested by using 1 GeV photons. The calorimeter consisted of nine crystals of 20 x 20 x 200 mm in size arranged in a 3 x 3 array. The energy resolution was obtained to be σ E /E = (2.50 ± 0.75%) / √E + (1.25 ± 0.34%) with a photomultiplier tube (PMT) reading all signals. Another setup, reading the central cell with an avalanche photo diode (APD) and the surrounding 8 cells with the PMT, was also studied, however, its energy resolution was not scaled with the stochastic function and we found the resolution of about 10% around 1 GeV. (author)

  2. CMS lead tungstate crystals

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    These crystals are made from lead tungstate, a crystal that is as clear as glass yet with nearly four times the density. They have been produced in Russia to be used as scintillators in the electromagnetic calorimeter on the CMS experiment, part of the LHC project at CERN. When an electron, positron or photon passes through the calorimeter it will cause a cascade of particles that will then be absorbed by these scintillating crystals, allowing the particle's energy to be measured.

  3. Studies of lead tungstate crystal matrices in high energy beams for the CMS electromagnetic calorimeter at the LHC

    CERN Document Server

    Alexeev, G; Baillon, Paul; Barney, D; Bassompierre, Gabriel; Bateman, E; Bell, K W; Benhammou, Ya; Bloch, P; Bomestar, D; Borgia, B; Bourotte, J; Burge, S R; Cameron, W; Chipaux, Rémi; Cockerill, D J A; Connolly, J; Dafinei, I; Denes, P; Depasse, P; Deiters, K; Dobrzynski, Ludwik; El-Mamouni, H; Faure, J L; Felcini, Marta; Finger, M H; Flügel, T; Gautheron, F; Givernaud, Alain; Gninenko, S N; Godinovic, N; Graham, D J; Guillaud, J P; Guschin, E; Haguenauer, Maurice; Hillemanns, H; Hofer, H; Ille, B; Jääskeläinen, S; Katchanov, V A; Kennedy, B W; Kirn, T; Korzhik, M V; Lassila-Perini, K M; Lebeau, M; Lebrun, P; Lecoq, P; Lecoeur, Gérard; Lecomte, P; Leonardi, E; Locci, E; Loos, R; Ma, D; Martin, F; Mendiburu, J P; Musienko, Yu V; Nédélec, P; Nessi-Tedaldi, F; Newbold, D; Newman, H; Oukhanov, M; Pacciani, L; Peigneux, J P; Pirro, S; Popov, S; Puljak, I; Purves, C; Renker, D; Rondeaux, F; Rosso, E; Rusack, R W; Rykaczewski, H; Schmitz, D; Schneegans, M; Schwenke, J; Seez, Christopher J; Semeniouk, I N; Shagin, P M; Shevchenko, S; Shi, X; Sillou, D; Simohand, D; Singovsky, A V; Soric, I; Smith, B; Stephenson, R; Verrecchia, P; Vialle, J P; Virdee, Tejinder S; Zhu, R Y

    1997-01-01

    Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic calorimeter read out by avalanche photodiodes can consistently achieve the excellent energy resolutions necessary to justify its construction in the CMS detector. The performance achieved has been understood in terms of the properties of the crystals and photodetectors.

  4. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Liang Ying; Zhu, R Y; Liu, D T

    2001-01-01

    Light monitoring will serve as an intercalibration for Compact Muon Solenoid (CMS) lead tungstate crystals in situ at the Large Hadronic Collider, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO/sub 4/ crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (12 refs).

  5. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Li Yuan; Zhu Ren Yuan; Liu Dun Can

    2000-01-01

    Light monitoring will serve as an inter calibration for CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's sub percent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO//4 crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. 29 Refs.

  6. Test results from a prototype lead tungstate crystal calorimeter with vacuum phototriode readout for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Apollonio, M; Barber, G; Bell, K; Britton, D; Brooke, J; Brown, R; Bourotte, J; Camanzi, B; Cockerill, D; Davies, G; Devitsin, E; Gninenko, S; Golubev, N; Goussev, Y; Grafstroem, P; Haguenauer, M; Head, R; Heath, H; Hobson, P; Inyakin, A; Katchanov, V; Kirsanov, M; Lintern, L; Lodge, A; Mcleod, E; Nash, S; Newbold, D; Ukhanov, M; Postoev, V; Patalakha, D; Presland, A; Probert, M; Seez, C; Semeniouk, I; Seliverstov, D; Smith, B; Sproston, M; Tapper, R; Tchuiko, B

    2002-05-21

    Tests of a prototype for the electromagnetic calorimeter (ECAL) of the compact muon solenoid experiment (CMS) at the large hadron collider are described. The basic unit for the endcap ECAL in CMS is a 'supercrystal' of 25 lead tungstate crystals. Results are presented from tests of the first full-sized supercrystal in electron beams and in a 3 T magnetic field. The supercrystal was exposed to electron beams with energies from 25 to 180 GeV. An energy resolution ({sigma}{sub E}/E) of (0.48{+-}0.01)% was measured at 180 GeV.

  7. A high resolution electromagnetic calorimeter based on lead-tungstate crystals

    Czech Academy of Sciences Publication Activity Database

    Aleksandrov, D. V.; Burachas, S.F.; Ippolitov, M.S.; Mareš, Jiří A.; Polák, Karel

    2005-01-01

    Roč. 550, - (2005), s. 169-184 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : PbWO 3 * high resolution electromagnetic calorimeter Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.224, year: 2005

  8. Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter

    CERN Document Server

    Auffray, Etiennette; Barney, D; Bassompierre, Gabriel; Benhammou, Ya; Blick, A M; Bloch, P; Bonamy, P; Bourotte, J; Buiron, L; Cavallari, F; Chipaux, Rémi; Cockerill, D J A; Dafinei, I; Davies, G; Depasse, P; Deiters, K; Diemoz, M; Dobrzynski, Ludwik; Donskov, S V; Mamouni, H E; Ercoli, C; Faure, J L; Felcini, Marta; Gautheron, F; Géléoc, M; Givernaud, Alain; Gninenko, S N; Godinovic, N; Graham, D J; Guillaud, J P; Guschin, E; Haguenauer, Maurice; Hillemanns, H; Hofer, H; Ille, B; Inyakin, A V; Jääskeläinen, S; Katchanov, V A; Kirn, T; Kloukinas, Kostas C; Korzhik, M V; Lassila-Perini, K M; Lebrun, P; Lecoq, P; Lecoeur, Gérard; Lecomte, P; Leonardi, E; Locci, E; Loos, R; Longo, E; MacKay, C K; Martin, E; Mendiburu, J P; Musienko, Yu V; Nédélec, P; Nessi-Tedaldi, F; Organtini, G; Paoletti, S; Pansart, J P; Peigneux, J P; Puljak, I; Qian, S; Reid, E; Renker, D; Rosowsky, A; Rosso, E; Rusack, R W; Rykaczewski, H; Schneegans, M; Seez, Christopher J; Semeniouk, I N; Shagin, P M; Sillou, D; Singovsky, A V; Sougonyaev, V; Soric, I; Verrecchia, P; Vialle, J P; Virdee, Tejinder S; Zhu, R Y

    1998-01-01

    Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than 0 .6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss of energy resolution after irradiation and that the calibration change due to light loss can be tracked with a precision monitoring system. Finally, successuful tests with a preshower device, equipped wi th silicon strip detector readout, are described.

  9. Dual-Readout Calorimetry with Lead Tungstate Crystals

    OpenAIRE

    Akchurin, N.

    2007-01-01

    Results are presented of beam tests in which a small electromagnetic calorimeter consisting of lead tungstate crystals was exposed to 50 GeV electrons and pions. This calorimeter was backed up by the DREAM Dual-Readout calorimeter, which measures the scintillation and \\v{C}erenkov light produced in the shower development, using two different media. The signals from the crystal calorimeter were analyzed in great detail in an attempt to determine the contributions from these two types of light ...

  10. Proposal for the award of a contract for the supply of 26 000 lead-tungstate scintillation crystals for the CMS electromagnetic calorimeter

    CERN Document Server

    2001-01-01

    This document concerns the award of a contract for the supply of 26 000 lead-tungstate scintillation crystals for the barrel part of the CMS Electromagnetic Calorimeter (ECAL). Following a CERN market survey (MS-2727/EP/CMS) carried out among seven firms in four Member States and two firms in two non-Member States, the Eidgenössische Technische Hochschule in Z rich (ETHZ) published on 15 February 2001 an open call for tenders and, in addition, invited tenders from four firms in two non-Member States, including the two firms identified in the CERN market survey. By the closing date, the ETHZ had received one bid from a firm in a CERN Member State and three bids from three firms in two non-Member States. The Finance Committee is invited to agree to the negotiation of a contract to be placed by CERN, on behalf of the ETHZ, with the lowest bidder, SCIONIX (NL), for the supply of 26 000 lead-tungstate crystals for the barrel part of the CMS ECAL for a total amount of 9 392 000 US dollars (16 060 320 Swiss francs)...

  11. The CMS crystal calorimeter

    CERN Document Server

    Lustermann, W

    2004-01-01

    The measurement of the energy of electrons and photons with very high accuracy is of primary importance far the study of many physics processes at the Large Hadron Collider (LHC), in particular for the search of the Higgs Boson. The CMS experiment will use a crystal calorimeter with pointing geometry, almost covering 4p, as it offers a very good energy resolution. It is divided into a barrel composed of 61200 lead tungstate crystals, two end-caps with 14648 crystals and a pre-shower detector in front of the end-cap. The challenges of the calorimeter design arise from the high radiation environment, the 4 Tesla magnetic eld, the high bunch crossing rate of 40 MHz and the large dynamic range, requiring the development of fast, radiation hard crystals, photo-detectors and readout electronics. An overview of the construction and design of the calorimeter will be presented, with emphasis on some of the details required to meet the demanding performance goals. 19 Refs.

  12. Testing the radiation hardness of lead tungstate scintillating crystals

    CERN Document Server

    Shao, M; Li Chuan; Chen, H; Xu, Z Z; Wang, Z M

    2000-01-01

    Large Hadron Collider operation will produce a high radiation background. PbWO/sub 4/ crystals are selected as scintillators for the CMS electromagnetic calorimeter. To reach the precise requirement for energy measurements, a strict requirement for the radiation hardness is needed. In this paper, we present a method for evaluating the radiation hardness and its measurement. Results for several full size (23 cm length) lead tungstate crystals under Co/sup 60/ gamma - ray irradiation are given, investigating the light yield loss and its longitudinal uniformity. (8 refs).

  13. Lead-Tungstate Crystal of the ALICE Photon Spectrometer (PHOS)

    CERN Multimedia

    2003-01-01

    The photon spectrometer (PHOS) is designed to measure the temperature of collisions by detecting photons emerging from them. It will be made of lead tungstate crystals like these. When high-energy photons strike lead tungstate, they make it glow, or scintillate, and this glow can be measured. Lead tungstate is extremely dense (denser than iron), stopping most photons that reach it.

  14. Application prospects of cadmium-containing crystals based on tungstates and double tungstates

    CERN Document Server

    Nagornaya, L; Apanasenko, A; Tupitsyna, I; Chernikov, V; Vostretsov, V

    2002-01-01

    Tungstate and double tungstate crystals of high scintillation efficiency and detectors based on them are applied widely in the medical imaging and radiation monitoring because of their high sensitivity to the ionizing radiation, small radiation length, high radiation hardness, low afterglow level. In this work a possibility to broaden the application field of CWO crystals have been investigated by improvement of their spectrometric quality and decreasing of their afterglow level. CWO crystals with improved characteristics have been obtained (resolution for sup 1 sup 3 sup 7 Cs <8%, afterglow <0.02% after 20 ms). A possibility is considered to use these crystals for spectrometry of thermal and resonance neutrons, which is possible due to the presence of nuclei with large cross-section for these neutrons in the crystal lattice. Compounds of a new type based on Cd, La-containing double tungstates doped with rare earth elements have been synthesized, and their luminescent characteristics have been studied. ...

  15. Monitoring and Correcting for Response Changes in the CMS Lead-tungstate Electromagnetic Calorimeter

    International Nuclear Information System (INIS)

    Ferri, Federico

    2012-01-01

    The CMS Electromagnetic Calorimeter (ECAL) comprises 75848 lead-tungstate scintillating crystals. Changes in the ECAL response, due to crystal radiation damage or changes in photo-detector output, are monitored in real time with a sophisticated system of lasers to allow corrections to the energy measurements to be calculated and used. The excellent intrinsic resolution of the CMS ECAL requires the monitoring system itself to be calibrated to a high precision and its stability to be controlled and understood. The components of the CMS ECAL monitoring system, and how it has evolved to include modern solid-state lasers, are described. Several physics channels are exploited to normalise the ECAL response to the changes measured by the monitoring system. These include low energy diphoton resonances, electrons from W and Z decays (using shower energy versus track momentum measurements), and the azimuthal symmetry of low energy deposits in minimum bias events. This paper describes how the monitoring system is operated, how the corrections are obtained, and the resulting ECAL performance.

  16. Lead tungstate crystal of the ALICE Photon Spectrometer (PHOS)

    CERN Document Server

    Patrice Loïez

    2002-01-01

    A consignment of 500 lead tungstate crystals arrived at CERN from the northern Russian town of Apatity in May. Destined for the ALICE heavy-ion experiment in preparation for the Large Hadron Collider, each crystal is an 18 cm long rod with a 2.2 cm square section, and weighs some 750 g. A total of 17 000 crystals will make up the experiment's photon spectrometer.

  17. Recent developments in crystal calorimeters (featuring the CMS PbWO4 electromagnetic calorimeter)

    International Nuclear Information System (INIS)

    Gascon-Shotkin, S.

    2003-01-01

    In the mass range of 110-150 GeV the favored process for Higgs boson detection via p-p collisions is via its decay into two photons, which demands a very high-resolution electromagnetic calorimeter. This physics goal plus the Large Hadron Calorimeter (LHC)-imposed design constraints of 25ns bunch spacing and a hostile radiation environment have led the Compact Muon Solenoid (CMS) collaboration to the choice of lead tungstate (PbWO 4 ) crystals. These factors plus the presence of a 4T magnetic field and the relatively low room-temperature scintillation photon yield of PbWO 4 make photo detection a real challenge, which CMS has met via the choice of devices providing gain amplification: Avalanche photodiodes (APD) in the central barrel region and vacuum phototriodes (VPT) in the forward and backward endcap regions. In the past year the CMS electromagnetic calorimeter has entered the construction phase. We review progress in the areas of crystals, barrel and endcap photo detection devices, plans for detector calibration as well as the status of assembly and quality control. We also invoke relevant developments in other crystal calorimeters currently in operation or under development. Crystal calorimeters remain the medium of choice for precision energy and position measurements in high energy physics

  18. Improvement of several properties of lead tungstate crystals with different doping ions

    CERN Document Server

    Auffray, Etiennette; Baccaro, Stefania; Cecilia, Angelica; Dafinei, Ioan; Diemoz, Marcella; Jarolímek, O; Korzhik, Mikhail; Lecoq, Paul; Nikl, M

    1998-01-01

    A very good radiation resistance of Lead Tungstate crystals is mandatory for their use in the high precision electromagnetic calorimeter of the CMS experiment at LHC. Since the beginning of 1996 we have organised systematic investigations of the parameters influencing the radiation hardness of this crystal. Two classes of parameters have been particularly studied, the first one related to the control of the stoichiometry and structure associated defects, the second one connected with the suppression and the charge compensation of existing defects with different kinds of doping ions. This paper reports about the second part of this study and complements a first paper where the role of the stoichiometry was already discussed. Results of tests are given on a significant statistical sample of full size crystals ( 23cm) which show a considerable improvement in the optical properties and the radiation resistance of appropriately doped crystals.

  19. Optimization of the scintillation parameters of the lead tungstate crystals for their application in high precision electromagnetic calorimetry

    International Nuclear Information System (INIS)

    Drobychev, G.

    2000-01-01

    In the frame of this dissertation work scintillation properties of the lead tungstate crystals PWO) and possibilities of their use were studied foreseeing their application for electromagnetic calorimetry in extreme radiation environment conditions of new colliders. The results of this work can be summarized in the following way. 1. A model of the scintillations origin in the lead tungstate crystals which includes processes influencing on the crystals radiation hardness and presence of slow components in scintillations was developed. 2. An analysis of the influences of the PWO scintillation properties changes on the parameters of the electromagnetic calorimeter was done. 3. Methods of the light collection from the large scintillation elements of complex shape made of the birefringent scintillation crystal with high refraction index and low light yield in case of signal registration by a photodetector with sensitive surface small in compare with the output face of scintillator were Studied. 4. Physical principles of the methodology of the scintillation crystals certification during their mass production foreseeing their installation into a calorimeter electromagnetic were developed. Correlations between the results of measurements of the PWO crystals parameters by different methods were found. (author)

  20. Optimization of the scintillation parameters of the lead tungstate crystals for their application in high precision electromagnetic calorimetry; Optimisation des parametres de scintillation des cristaux de tungstate de plomb pour leur application dans la calorimetrie electromagnetique de haute precision

    Energy Technology Data Exchange (ETDEWEB)

    Drobychev, G

    2000-04-12

    In the frame of this dissertation work scintillation properties of the lead tungstate crystals (PWO) and possibilities of their use were studied foreseeing their application for electromagnetic calorimetry in extreme radiation environment conditions of new colliders. The results of this work can be summarized in the following way. 1. A model of the scintillations origin in the lead tungstate crystals which includes processes influencing on the crystals radiation hardness and presence of slow components in scintillations was developed. 2. An analysis of the influences of the PWO scintillation properties changes on the parameters of the electromagnetic calorimeter was done. 3. Methods of the light collection from the large scintillation elements of complex shape made of the birefringent scintillation crystal with high refraction index and low light yield in case of signal registration by a photodetector with sensitive surface small in compare with the output face of scintillator were Studied. 4. Physical principles of the methodology of the scintillation crystals certification during their mass production foreseeing their installation into a calorimeter electromagnetic were developed. Correlations between the results of measurements of the PWO crystals parameters by different methods were found. (author)

  1. Luminescence spectra of lead tungstate, spodumene and topaz crystals

    International Nuclear Information System (INIS)

    Ramachandran, Vasuki

    2002-01-01

    A detailed set of thermoluminescence, cathodoluminescence and radioluminescence (TL, CLTL and RLTL) data of lead tungstate, Spodumene and Topaz have been reported for the first time over a wide temperature range from 25 to 500K. Lead tungstate (PbWO 4 ), a widely known scintillating material, gives TL glow peaks which are related to complex defect centres. Doping of this crystal with trivalent rare earth ions (La 3+ , Y 3+ ) reduces the slow component of the emission thereby making it more suitable for its applications. The pentavalent dopants on the other hand, enhance the green emission and quench the blue emission at temperatures 100K. The origin and the irradiation temperature definitely have an effect on the spectrum. No strong relationship could be derived from the dose dependence data. Two less studied minerals, Spodumene and Topaz have also been investigated with the luminescence techniques. The glow peak near 250degC is thought to have originated from Mn 2+ centres. As there are no ESR data available, the assignment of defect centres is rather difficult. Cr + acts as the quencher in green spodumene. Topaz had the same treatment as the other two sets of samples and the defect centre characterisation looks complex as each coloured sample gave different patterns of glow peaks. Cathodoluminescence whilst heating (CLTL) of all these samples showed some unusual features in the form of a luminescence intensity step which is believed to have originated from the presence of ice. Water, in nanoparticle size quantities, is present as a contaminant in the lattice and undergoes a phase transition at 170K from hexagonal to cubic structures. This phase change influences the luminescence efficiency of the host material and is reflected in the spectrum as a discontinuity in intensity. (author)

  2. Quality inspection of anisotropic scintillating lead tungstate (PbWO 4) crystals through measurement of interferometric fringe pattern parameters

    Science.gov (United States)

    Cocozzella, N.; Lebeau, M.; Majni, G.; Paone, N.; Rinaldi, D.

    2001-08-01

    Scintillating crystals are widely used as detectors in radiographic systems, computerized axial tomography devices and in calorimeters employed in high-energy physics. This paper results from a project motivated by the development of the CMS calorimeter at CERN, which will make use of a large number of scintillating crystals. In order to prevent crystals from breaking because of internal residual stress, a quality control system based on optic inspection of interference fringe patterns was developed. The principle of measurement procedures was theoretically modelled, and then a dedicated polariscope was designed and built, in order to observe the crystals under induced stresses or to evaluate the residual internal stresses. The results are innovative and open a new perspective for scintillating crystals quality control: the photoelastic constant normal to the optic axis of the lead tungstate crystals (PbWO 4) was measured, and the inspection procedure developed is applicable to mass production, not only to optimize the crystal processing, but also to establish a quality inspection procedure.

  3. Quality inspection of anisotropic scintillating lead tungstate (PbWO4) crystals through measurement of interferometric fringe pattern parameters

    International Nuclear Information System (INIS)

    Cocozzella, N.; Lebeau, M.; Majni, G.; Paone, N.; Rinaldi, D.

    2001-01-01

    Scintillating crystals are widely used as detectors in radiographic systems, computerized axial tomography devices and in calorimeters employed in high-energy physics. This paper results from a project motivated by the development of the CMS calorimeter at CERN, which will make use of a large number of scintillating crystals. In order to prevent crystals from breaking because of internal residual stress, a quality control system based on optic inspection of interference fringe patterns was developed. The principle of measurement procedures was theoretically modelled, and then a dedicated polariscope was designed and built, in order to observe the crystals under induced stresses or to evaluate the residual internal stresses. The results are innovative and open a new perspective for scintillating crystals quality control: the photoelastic constant normal to the optic axis of the lead tungstate crystals (PbWO 4 ) was measured, and the inspection procedure developed is applicable to mass production, not only to optimize the crystal processing, but also to establish a quality inspection procedure

  4. Progress in the Development of the Lead Tungstate Crystals for EM-Calorimetry in High-Energy Physics

    Science.gov (United States)

    Novotny, R. W.; Brinkmann, K.-T.; Borisevich, A.; Dormenev, V.; Houzvicka, J.; Korjik, M.; Zaunick, H.-G.

    2017-11-01

    Even at present time there is a strong interest and demand for high quality lead tungstate crystals (PbWO4, PWO) for electromagnetic (EM) calorimetry. PWO is implemented into the EM calorimeter of the CMS-ECAL detector at LHC [1] and required for the completion of the PANDA EMC [2] and various ongoing detector projects at Jefferson Lab. The successful mass production of PWO using the Czochralski method was stopped after bankruptcy of the Bogoroditsk Technical Chemical Plant (BTCP) in Russia as major producer so far. The Shanghai Institute of Ceramics, Chinese Academy of Science (China) was considered as an alternative producer using the modified Bridgman method. The company CRYTUR (Turnov, Czech Republic) with good experience in the development and production of different types of inorganic oxide crystals has restarted at the end of 2014 the development of lead tungstate for mass production based on the Czochralski method. An impressive progress was achieved since then. The growing technology was optimized to produce full size samples with the quality meeting the PANDA-EMC specifications for PWO-II. We will present a detailed progress report on the research program in collaboration with groups at Orsay and JLab. The full size crystals will be characterized with respect to optical performance, light yield, kinetics and radiation hardness.

  5. LYSO crystal calorimeter readout with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Berra, A., E-mail: alessandro.berra@gmail.com [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Cecchi, C.; Germani, S. [INFN sezione di Perugia (Italy); Guffanti, D. [Università degli Studi dell' Insubria (Italy); Lietti, D. [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Lubrano, P.; Manoni, E. [INFN sezione di Perugia (Italy); Prest, M. [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Rossi, A. [INFN sezione di Perugia (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2014-11-01

    Large area Silicon PhotoMultipliers (SiPMs) are the new frontier of the development of readout systems for scintillating detectors. A SiPM consists of a matrix of parallel-connected silicon micropixels operating in limited Geiger–Muller avalanche mode, and thus working as independent photon counters with a very high gain (∼10{sup 6}). This contribution presents the performance in terms of linearity and energy resolution of an electromagnetic homogeneous calorimeter composed of 9∼18X{sub 0} LYSO crystals. The crystals were readout by 36 4×4 mm{sup 2} SiPMs (4 for each crystal) produced by FBK-irst. This calorimeter was tested at the Beam Test Facility at the INFN laboratories in Frascati with a single- and multi-particle electron beam in the 100–500 MeV energy range.

  6. Properties of lead tungstate crystals for high-energy physics

    CERN Document Server

    Ippolitov, M S; Burachas, S; Ikonnikov, V; Kuriakin, A; Lebedev, V; Makov, I; Man'ko, V; Nikulin, S P; Nyanin, A; Saveliev, Yu; Tamulaitis, G; Tsvetkov, A A; Vasilev, A; Vinogradov, Yu I

    2004-01-01

    Technology for the mass production of high-quality PbWO//4 (PWO) scintillating crystals is described. Scintillators produced from PWO crystals are intented for the ALICE CERN heavy ion experiment. Light yield, emission and decay time spectra as well as optical transmission of about 3600 crystals (dimensions 22 multiplied by 22 multiplied by 180 mm**3) were measured. Beam-test results of the ALICE PHOS prototype obtained with such PWO crystals are presented.

  7. Lead tungstate crystals for the ALICE/CERN experiment

    CERN Document Server

    Ippolitov, M S; Burachas, S; Ikonnikov, V; Kuriakin, A; Lebedev, V; Makov, I; Man'ko, V; Nikulin, S; Nyanin, A; Saveliev, Yu; Tamulaitis, G; Tsvetkov, A; Vasilev, A; Vinogradov, Yu I

    2005-01-01

    Light yield, emission and decay time spectra, and optical transmission of similar to 3600 (dimensions 22 multiplied by 22 multiplied by 180 mm**3) PbWO//4 (PWO) crystals were measured with test benches. Radiation beam-test results of PWO crystals are presented.

  8. Scintillation of lead tungstate crystal studied with single-electron beam from KUFEL

    Energy Technology Data Exchange (ETDEWEB)

    Rizwan, Mohamad, E-mail: rizwan@nucl.kyushu-u.ac.jp; Uozumi, Yusuke; Matsuo, Kazuki [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Fukuoka (Japan); Ohgaki, Hideaki; Kii, Toshiteru; Zen, Heishun [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto (Japan); Tsamalaidze, Zviadi; Evtoukhovitch, Petr; Valentin, Samoilov [Joint Institute for Nuclear Research, JINR, Joliot-Curie Str.6, Dubna (Russian Federation)

    2015-04-29

    Lead tungstate (PWO) crystal has a very fast response, high atomic density and high radiation hardness. Therefore, they are suitable to be used for high-energy nuclear data measurements under high-background circumstances. Although a good electron-ion separation with a pulse shape analysis technique is essential, scintillation pulse shapes have not been observed with electron beams of a wide energy range. A single-electron beam technique has been developed at Kyoto University Free Electron Laser (KUFEL), and electron beams of 4-38 MeV are available. During the experiments, single electron beams bombarded a PWO crystal. By using oscilloscope we observed scintillation pulses of a PWO crystal coupled with a photomultiplier tube. Measured spectra were compared with the simulation code of EGS5 to analyze scattering effects. As the result, the pulse amplitudes show good linearity and the pulse shapes are almost constant in the observed energy range.

  9. Analysis of photoluminescence spectra of lead-tungstate single crystals

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Lee, Sang Yun; Lee, Myoung Bok

    2003-01-01

    In addition to the intrinsic blue emission band near 430 nm for an ideal PbWO 4 scheelite structure, the presence of three extra emission bands peaking near blue-green and green-red colors was clearly identified for thermally synthesized bulk crystals with the help of a reliable fitting process applicable for microscopic analysis of recorded PL spectra. The origin, nature, and electro-optical behaviors of the extra emission bands are strongly related to the structural change from an ideal scheelite to modified ones, so now we can more closely track down the nature and the relevant behaviors, which are still in dispute, of the apparent colors of the PbWO 4 scintillating medium by constructing structural models and by considering the energy transfer mechanism between the color centers

  10. Correlation of beam electron and LED signal losses under irradiation and long-term recovery of lead tungstate crystals

    International Nuclear Information System (INIS)

    Batarin, V.A.; Butler, J.; Davidenko, A.M.; Derevschikov, A.A.; Goncharenko, Y.M.; Grishin, V.N.; Kachanov, V.A.; Konstantinov, A.S.; Kravtsov, V.I.; Kubota, Y.; Lukanin, V.S.; Matulenko, Y.A.; Melnick, Y.M.; Meschanin, A.P.; Mikhalin, N.E.; Minaev, N.G.; Mochalov, V.V.; Morozov, D.A.; Nogach, L.V.; Ryazantsev, A.V.; Semenov, P.A.; Semenov, V.K.; Shestermanov, K.E.; Soloviev, L.F.; Stone, S.; Uzunian, A.V.; Vasiliev, A.N.; Yakutin, A.E.; Yarba, J.

    2005-01-01

    Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystal recovery from such damage

  11. The electromagnetic calorimeter of the CMS experiment

    International Nuclear Information System (INIS)

    Diemoza, M.

    2003-01-01

    The Electromagnetic Calorimeter of the CMS experiment is made of about 80000 Lead Tungstate scintillating crystals. This project aims to achieve an extreme precision in photons and electrons energy measurement. General motivations, main technical challenges and key points in energy resolution will be discussed in the following

  12. Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Auffray, Etiennette; Baccaro, Stefania; Baffioni, Stephanie; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Berthon, Ursula; Betev, Botjo; Beuselinck, Raymond; Bhardwaj, Ashutosh; Biino, Cristina; Bimbot, Stephane; Blaha, Jan; Bloch, Philippe; Blyth, Simon; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton1, D; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Cerutti, Muriel; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chatterji, Sudeep; Chen, E Augustine; Chipaux, Rémi; Choudhary, Brajesh C; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Cossutti, Fabio; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; Debraine, Alain; Decotigny, David; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Della Ricca, Giuseppe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Golutvin, Igor; Gómez-Reino, Robert; Govoni, Pietro; Grahl1, J; Gras1, P; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel-de-Montechenault, G; Hansen, Magnus; Heath, Helen F; AHill, J; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Jarry, Patrick; Jauffret, C; Jha, Manoj; Karar, Akli; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Litvin, V; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Luckey, D; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Malberti, Martina; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Mathieu, Antoine; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman26, H B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rahatlou, Shahram; Rander, John; Ranjan, Kirti; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rumerio, Paolo; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Seez, Christopher; Semeniouk, Igor; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Timlin, Claire; ATriantis, F; Troshin, Sergey; Tyurin, Nikolay; Ueno, Koji; Uzunian, Andrey; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Vigano, S; Viertel, Gert; Virdee, Tejinder; Vlassov, E; Wang, Minzu; Weinstein, Alan; Williams, Jennifer C; Yaselli, Ignacio; Zabi, Alexandre; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhang, Yawei; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals.

  13. Certifying procedures for lead tungstate crystal parameters during mass production for the CMS ECAL

    CERN Document Server

    Auffray, Etiennette; Chipaux, Rémi; Drobychev, G Yu; Dromby, G; Fedorov, A A; Freire, M; Géléoc, M; Kondratev, O V; Korzhik, M V; Lecoq, P; Le Goff, J M; Letournel, P; Lopatic, A R; Missevitch, O V; Oriboni, A; Oskine, A V; Panov, B M; Peigneux, J P; Schneegans, M; Singovsky, A V; Zouevski, R F

    1998-01-01

    Certifying procedures and fully automated equipment for testing of Pb WO/sub 4/ (PWO) scintillators have been developed. The parameters to be verified are the optical transmission spectra in the longitudinal and transversal $9 directions; the light yield and its non-uniformity along the crystal; the scintillation kinetics; the radiation hardness and the dimensions. Both the precision of measurements and the output rate meet the stringent requirements of $9 the mass production stage of PWO scintillating elements for the CMS electromagnetic calorimeter at CERN (full characterization of several tens of crystals per day for five years). This is achieved by a) the implementation of a $9 `start- stop' technique with high count rate capability for scintillation decay measurement; b) the development of special compact fast scanning spectrophotometers; c) the application of a multi-axis movement system for crystal and $9 spectrometers; d) the use of a standard programmable 3D machine for precise dimension measurement....

  14. On the ionization scintillation calorimeter based on KMgF3 crystal

    International Nuclear Information System (INIS)

    Buzulutskov, A.F.

    1990-01-01

    The development of the ionization scintillation calorimeter, using KMgF 3 crystals and high efficiency photocathodes, is proposed. Some characteristics of such calorimeter are compared with those of the high pressure gas one. 6 refs.; 2 figs.; 2 tabs

  15. Studies in crystal structure and luminescence properties of Eu3+-doped metal tungstate phosphors for white LEDs

    International Nuclear Information System (INIS)

    Lee, Gwan-Hyoung; Kang, Shinhoo

    2011-01-01

    The correlation between the crystal structure and luminescent properties of Eu 3+ -doped metal tungstate phosphors for white LEDs was investigated. Red-emitting A 4-3x (WO 4 ) 2 :Eu x 3+ (A=Li, Na, K) and B (4-3x)/2 (WO 4 ) 2 :Eu x 3+ (B=Mg, Ca, Sr) phosphors were synthesized by solid-state reactions. The findings confirmed that these phosphors exhibited a strong absorption in the near UV to green range, due to the intra-configurational 4f-4f electron transition of Eu 3+ ions. The high doping concentration of Eu 3+ enhanced the absorption of near UV light and red emission without any detectable concentration quenching. Based on the results of a Rietveld refinement, it was attributed to the unique crystal structure. In the crystal structure of the Eu 3+ -doped metal tungstate phosphor, the critical energy transfer distance is larger than 5 A so that exchange interactions between Eu 3+ ions would occur with difficulty, even at a high doping concentration. The energy transfer between Eu 3+ ions, which causes a decrease in red emission with increasing concentration of Eu 3+ , appears to be due to electric multi-polar interactions. In addition, the Eu-O distance in the host lattice affected the shape of emission spectrum by splitting of emission peak at the 5 D 0 → 7 F 2 transition of Eu 3+ . - Highlights: → Eu 3+ -doped metal tungstate was synthesized as a red phosphor for white LEDs. → Crystal structure is tetragonal with a space group of I4 1 /c. → A strong absorption in the near UV to green range was observed. → High doping of Eu 3+ enhanced the absorption of near UV light and red emission.

  16. Design and Status of the Mu2e Crystal Calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Atanov, N.; et al.

    2018-01-08

    The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

  17. CCALT: A crystal calorimeter for the KLOE-2 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Cordelli, M; Happacher, F; Martini, M; Miscetti, S; Sarra, I [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Schioppa, M; Stucci, S, E-mail: fabio.happacher@lnf.infn.it [INFN and Department of Physics, University of Calabria, Cosenza (Italy)

    2011-04-01

    The angular coverage extension of the KLOE-2 electromagnetic calorimeter, from a polar angle of 20{sup 0} down to 10{sup 0}, will increase the multiphoton detection capability of the experiment enhancing the search reach for rare kaon, {eta} and {eta}' prompt decay channels. The basic layout of the calorimeter extension consists of two small barrels of LYSO crystals readout with APD photosensors aiming to achieve a timing resolution between 300 and 500 ps for 20 MeV photons. The first test of a (5.5x6x13) cm{sup 3} prototype for such a detector wa s carried out at the Beam Test Facility of Laboratori Nazionali di Frascati of INFN. We present here the results ofthis test.

  18. The Mu2e undoped CsI crystal calorimeter

    Science.gov (United States)

    Atanov, N.; Baranov, V.; Budagov, J.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Davydov, Y. I.; Di Falco, S.; Diociaiuti, E.; Donati, S.; Donghia, R.; Echenard, B.; Giovannella, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Martini, M.; Miscetti, S.; Miyashita, T.; Morescalchi, L.; Murat, P.; Pedreschi, E.; Pezzullo, G.; Porter, F.; Raffaelli, F.; Ricci, M.; Saputi, A.; Sarra, I.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Zhu, R. Y.

    2018-02-01

    The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

  19. Incipient crystallization of transition-metal tungstates under microwaves probed by Raman scattering and transmission electron microscopy

    International Nuclear Information System (INIS)

    Siqueira, Kisla P. F.; Dias, Anderson

    2011-01-01

    Microwave synthesis was used to produce nanosized transition-metal tungstates in environmentally friendly conditions not yet reported by the literature: 110 and 150 °C, for times of 10 and 20 min. X-ray diffraction evidenced incipient crystallized materials, while transmission electron microscopy indicates nanostructured regions of about 2–5 nm inside an amorphous matrix. Raman spectroscopy was used to probe short-range ordering in the achieved samples and also to obtain a reliable set of spectra containing all the Raman-active bands predicted by group-theory calculations. The vibrational spectra showed no extra feature, indicating that the microwave processing was able to produce short-range ordered materials without tetrahedral distortions. These distortions are frequently reported when commercially modified kitchen microwave units are employed. In this work, the syntheses were conducted in a commercial apparatus especially designed for fully controlled temperature–time–pressure conditions.

  20. The New APD Based Readout for the Crystal Barrel Calorimeter

    International Nuclear Information System (INIS)

    Urban, M; Honisch, Ch; Steinacher, M

    2015-01-01

    The CBELSA/TAPS experiment at ELSA measures double polarization observables in meson photoproduction off protons and neutrons. To be able to measure purely neutral reactions off polarized neutrons with high efficiency, the main calorimeter has to be integrated into the first level trigger. This requires to exchange the existing PIN photo diode by a new avalanche photo diode (APD) readout. The newly developed readout electronics will provide an energy resolution compatible to the previous set-up and a fast trigger signal down to 10 MeV energy deposit per crystal. After the successful final tests with a 3x3 CsI crystal matrix in Bonn at ELSA and in Mainz at MAMI all front-end electronics were produced in fall 2013. Automated test routines for the front-end electronics were developed and the characterization measurements of all APDs were successfully accomplished in Bonn. The project is supported by the Deutsche Forschungsgemeinschaft (SFB/TR16) and Schweizerischer Nationalfonds

  1. Last crystals for the CMS chandelier

    CERN Multimedia

    2008-01-01

    In March, the last crystals for CMS’s electromagnetic calorimeter arrived from Russia and China. Like dedicated jewellers crafting an immense chandelier, the CMS ECAL collaborators are working extremely hard to install all the crystals before the start-up of the LHC. One of the last CMS end-cap crystals, complete with identification bar code. Lead tungstate crystals mounted onto one section of the CMS ECAL end caps. Nearly 10 years after the first production crystal arrived at CERN in September 1998, the very last shipment has arrived. These final crystals will be used to complete the end-caps of the electromagnetic calorimeter (ECAL) at CMS. All in all, there are more than 75,000 crystals in the ECAL. The huge quantity of CMS lead tungstate crystals used in the ECAL corresponds to the highest volume ever produced for a single experiment. The excellent quality of the crystals, both in ter...

  2. Radiation Hardness Study of CsI(Tl) Crystals for Belle II Calorimeter

    CERN Document Server

    Matvienko, D V; Sedov, E V; Shwartz, B A

    2017-01-01

    The Belle II calorimeter (at least, its barrel part) consists of CsI(Tl) scintillation crystals which have been used at the Belle experiment. We perform the radiation hardness study of some typical Belle crystals and conclude their light output reductions are acceptable for Belle II experiment where the absorption dose can reach 10 krad during the detector operation. CsI(Tl) crystals have high stablity and low maintenance cost and are considered as possible option for the calorimeter of the future Super-Charm-Tau factory (SCT) in Novosibirsk. Our study demonstrates sufficiently high radiation hardness of CsI(Tl) crystals for SCT conditions.

  3. Experimental Study of the Lead Tungstate Scintillator Proton-Induced Damage and Recovery

    CERN Document Server

    Auffray, Etiennette; Singovski , A

    2011-01-01

    Lead tungstate (PbWO4, or PWO) scintillating crystals are used by two of the four experiments at the Large Hadron Collider (LHC): 75848 in CMS and 17920 in ALICE. For the CMS electromagnetic calorimeter, one of the most important crystal properties is its radiation hardness. With the increase of luminosity, the radiation level will increase drastically, particularly in the high pseudorapidity regions of the calorimeter. Beside the effects of color-centre formation caused by gamma-radiation, additional measurable effect originated by hadron irradiation could appear, which will further deteriorate the optical transmission of the crystals and therefore their efficiency. In this paper, we will present results of the proton-induced damage in PWO and a study of optical transmission recovery at different temperatures and under different light-induced "bleaching" conditions for proton-irradiated crystals.

  4. The CMS Electromagnetic Calorimeter: Construction, Commissioning and Calibration

    CERN Document Server

    ORIMOTO,Toyoko J.

    2009-01-01

    The Compact Muon Solenoid (CMS) detector at the Large Hadron Colider (LHC) is ready for first collisions. The Electromagnetic Calorimeter (ECAL) of CMS, a high resolution detector comprised of nearly 76000 lead tungstate crystals, will play a crucial role in the coming physics searches undertaken by CMS. The design and performance of the CMS ECAL with test beams, cosmic rays, and first single beam data will be presented. In addition, the status of the calorimeter and plans for calibration with first collisions will be discussed. European Physical Society Europhysics Conference on High Energy Physics July 16-22, 2009 Krakow, Poland ∗Speaker.

  5. The CMS Electromagnetic Calorimeter: Construction, Commissioning and Calibration

    CERN Document Server

    Orimoto, Toyoko

    2009-01-01

    The Compact Muon Solenoid (CMS) detector at the Large Hadron Colider (LHC) is ready for first collisions. The Electromagnetic Calorimeter (ECAL) of CMS, a high resolution detector comprised of nearly 76000 lead tungstate crystals, will play a crucial role in the coming physics searches undertaken by CMS. The design and performance of the CMS ECAL with test beams, cosmic rays, and first single beam data will be presented. In addition, the status of the calorimeter and plans for calibration with first collisions will be discussed.

  6. In-Situ Calibration of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Futyan, D I

    2003-01-01

    The in-situ intercalibration of the lead tungstate crystals of the CMS electromagnetic calorimeter will be performed using 3 techniques: An energy flow method will be used at startup to intercalibrate to a precision of around 2% within about 3 hours. The energy/momentum measurement of isolated electrons from W decay will then be used to obtain the design goal precision of 0.5% within about 2 months. Global intercalibration of different regions of the calorimeter and the determination of the absolute energy scale will be performed using energetic electrons from Z->ee events.

  7. Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, P.; Andelin, D.; Anicin, I.; Antunovic, Z.; Arcidiacono, R.; Arenton, M.W.; Auffray, E.; Argiro, S.; Askew, A.; Baccaro, S.; Baffioni, S.; Balazs, M.; Bandurin, D.; Barney, D.; Barone, L.M.; Bartoloni, A.; Baty, C.; Beauceron, S.; Bell, K.W.; Bernet, C.; Besancon, M.; Betev, B.; Beuselinck, R.; Biino, C.; Blaha, J.; Bloch, P.; Borisevitch, A.; Bornheim, A.; Bourotte, J.; Brown, R.M.; Buehler, M.; Busson, P.; Camanzi, B.; Camporesi, T.; Cartiglia, N.; Cavallari, F.; Cecilia, A.; Chang, P.; Chang, Y.H.; Charlot, C.; Chen, E.A.; Chen, W.T.; Chen, Z.; Chipaux, R.; Choudhary, B.C.; Choudhury, R.K.; Cockerill, D.J.A.; Conetti, S.; Cooper, S.I.; Cossutti, F.; Cox, B.; Cussans, D.G.; Dafinei, I.; Da Silva Di Calafiori, D.R.; Daskalakis, G.; David, A.; Deiters, K.; Dejardin, M.; De Benedetti, A.; Della Ricca, G.; Del Re, D.; Denegri, D.; Depasse, P.; Descamps, J.; Diemoz, M.; Di Marco, E.; Dissertori, G.; Dittmar, M.; Djambazov, L.; Djordjevic, M.; Dobrzynski, L.; Dolgopolov, A.; Drndarevic, S.; Drobychev, G.; Dutta, D.; Dzelalija, M.; Elliott-Peisert, A.; El Mamouni, H.; Evangelou, I.; Fabbro, B.; Faure, J.L.; Fay, J.; Fedorov, A.; Ferri, F.; Franci, D.; Franzoni, G.; Freudenreich, K.; Funk, W.; Ganjour, S.; Gascon, S.; Gataullin, M.; Gentit, F.X.; Ghezzi, A.; Givernaud, A.; Gninenko, S.; Go, A.; Gobbo, B.; Godinovic, N.; Golubev, N.; Govoni, P.; Grant, N.; Gras, P.; Haguenauer, M.; Hamel de Monchenault, G.; Hansen, M.; Haupt, J.; Heath, H.F.; Heltsley, B.; Cornell U., LNS.; Hintz, W.; Hirosky, R.; Hobson, P.R.; Honma, A.; Hou, G.W.S.; Hsiung, Y.; Huhtinen, M.; Ille, B.; Ingram, Q.; Inyakin, A.; Jarry, P.; Jessop, C.; Jovanovic, D.; Kaadze, K.; Kachanov, V.; Kailas, S.; Kataria, S.K.; Kennedy, B.W.; Kokkas, P.; Kolberg, T.; Korjik, M.; Krasnikov, N.; Krpic, D.; Kubota, Y.; Kuo, C.M.; Kyberd, P.; Kyriakis, A.; Lebeau, M.; Lecomte, P.; Lecoq, P.; Ledovskoy, A.; Lethuillier, M.; Lin, S.W.; Lin, W.; Litvine, V.; Locci, E.; Longo, E.; Loukas, D.; Luckey, P.D.; Lustermann, W.; Ma, Y.; Malberti, M.; Malcles, J.; Maletic, D.; Manthos, N.; Maravin, Y.; Marchica, C.; Marinelli, N.; Markou, A.; Markou, C.; Marone, M.; Matveev, V.; Mavrommatis, C.; Meridiani, P.; Milenovic, P.; Mine, P.; Missevitch, O.; Mohanty, A.K.; Moortgat, F.; Musella, P.; Musienko, Y.; Nardulli, A.; Nash, J.; Nedelec, P.; Negri, P.; Newman, H.B.; Nikitenko, A.; Nessi-Tedaldi, F.; Obertino, M.M.; Organtini, G.; Orimoto, T.; Paganoni, M.; Paganini, P.; Palma, A.; Pant, L.; Papadakis, A.; Papadakis, I.; Papadopoulos, I.; Paramatti, R.; Parracho, P.; Pastrone, N.; Patterson, J.R.; Pauss, F.; Peigneux, J.P.; Petrakou, E.; Phillips, D.G.; Piroue, P.; Ptochos, F.; Puljak, I.; Pullia, A.; Punz, T.; Puzovic, J.; Ragazzi, S.; Rahatlou, S.; Rander, J.; Razis, P.A.; Redaelli, N.; Renker, D.; Reucroft, S.; Ribeiro, P.; Rogan, C.; Ronquest, M.; Rosowsky, A.; Rovelli, C.; Rumerio, P.; Rusack, R.; Rusakov, S.V.; Ryan, M.J.; Sala, L.; Salerno, R.; Schneegans, M.; Seez, C.; Sharp, P.; Shepherd-Themistocleous, C.H.; Shiu, J.G.; Shivpuri, R.K.; Shukla, P.; Siamitros, C.; Sillou, D.; Silva, J.; Silva, P.; Singovsky, A.; Sirois, Y.; Sirunyan, A.; Smith, V.J.; Stockli, F.; Swain, J.; Tabarelli de Fatis, T.; Takahashi, M.; Tancini, V.; Teller, O.; Theofilatos, K.; Thiebaux, C.; Timciuc, V.; Timlin, C.; Titov, Maxim P.; Topkar, A.; Triantis, F.A.; Troshin, S.; Tyurin, N.; Ueno, K.; Uzunian, A.; Varela, J.; Verrecchia, P.; Veverka, J.; Virdee, T.; Wang, M.; Wardrope, D.; Weber, M.; Weng, J.; Williams, J.H.; Yang, Y.; Yaselli, I.; Yohay, R.; Zabi, A.; Zelepoukine, S.; Zhang, J.; Zhang, L.Y.; Zhu, K.; Zhu, R.Y.

    2010-01-01

    Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.

  8. Simulation studies of crystal-photodetector assemblies for the Turkish accelerator center particle factory electromagnetic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kocak, F., E-mail: fkocak@uludag.edu.tr

    2015-07-01

    The Turkish Accelerator Center Particle Factory detector will be constructed for the detection of the produced particles from the collision of a 1 GeV electron beam against a 3.6 GeV positron beam. PbWO{sub 4} and CsI(Tl) crystals are considered for the construction of the electromagnetic calorimeter part of the detector. The generated optical photons in these crystals are detected by avalanche or PIN photodiodes. Geant4 simulation code has been used to estimate the energy resolution of the calorimeter for these crystal–photodiode assemblies.

  9. Precision machining and polishing of scintillating crystals for large calorimeters and hodoscopes

    International Nuclear Information System (INIS)

    Wuest, C.R.; Fuchs, B.A.

    1993-05-01

    New machining and polishing techniques have been developed for large barium fluoride scintillating crystals that provide crystalline surfaces without sub-surface damage or deformation as verified by Atomic Force Microscopy (AFM) and Rutherford Back-scattering (RBS) analyses. Surface roughness of about 10--20 angstroms and sub-micron mechanical tolerances have been demonstrated on large crystal samples. Mass production techniques have also been developed for machining and polishing up to five 50 cm long crystals at one time. We present this technology along with surface studies of barium fluoride crystals polished with this technique. This technology is applicable for a number of new crystal detectors proposed at Colliders including the Barium Fluoride Electromagnetic Calorimeter at SSC, the Crystal Clear Collaboration's cerium fluoride calorimeter at LHC, and the KTeV and PHENIX scintillating hodoscopes at Fermilab, and RHIC, respectively. Lawrence Livermore National Laboratory (LLNL) has an active program of study on barium fluoride scintillating crystals for the Barium Fluoride Electromagnetic Calorimeter Collaboration and cerium fluoride and lead fluoride for the Crystal Clear Collaboration. This program has resulted in a number of significant improvements in the mechanical processing, polishing and coating of fluoride crystals. Techniques have been developed using diamond-loaded pitch lapping that can produce 15 angstrom RMS surface finishes over large areas. Also, special polishing fixtures have been designed based on mounting technology developed for the 1.1 m diameter optics used in LLNL's Nova Laser. These fixtures allow as many as five 25--50 cm long crystals to be polished and lapped at the same time with tolerances satisfying the stringent requirements of crystal calorimeters. We also discuss results on coating barium fluoride with UV reflective layers of magnesium fluoride and aluminum

  10. Non-stoichiometry defects and radiation hardness of lead tungstate crystals PbWO sub 4

    CERN Document Server

    Devitsin, E G; Potashov, S Yu; Terkulov, A R; Nefedov, V A; Polyansky, E V; Zadneprovski, B I; Kjellberg, P; Korbel, V

    2002-01-01

    It has been stated many times that the formation of radiation infringements in PbWO sub 4 is to a big extent stipulated by the non-stoichiometry defects of the crystals, arising in the process of their growth and annealing. To refine the idea of characteristics of the non-stoichiometry defects and their effect on the radiation hardness of PbWO sub 4 , the current study is aimed at the melt composition infringements during its evaporation and at optical transmission of crystals obtained in these conditions after their irradiation ( sup 1 sup 3 sup 7 Cs source). In the optical transmission measurements along with traditional techniques a method 'in situ' was used, which provided the measurements in fixed points of the spectrum (380, 470 and 535 nm) directly in the process of the irradiation. X-ray phase and fluorescence analysis of condensation products of vapours over PbWO sub 4 melt has found PbWO sub 4 phase in their content as well as compounds rich in lead PbO, Pb sub 2 WO sub 5 with overall ratio Pb/W (3....

  11. Non-stoichiometry Defects and Radiation Hardness of Lead Tungstate Crystals PbWO4

    CERN Document Server

    Devitsin, E G; Kozlov, V A; Nefedov, L; Polyansky, E V; Potashov, S Yu; Terkulov, A R; Zadneprovski, B I

    2001-01-01

    It has been stated many times that the formation of radiation infringements in PbWO4 is to big extent stipulated by non-stoichiometry defects of the crystals, arising in the process of their growth and annealing. To refine the idea of characteristics of non-stoichiometry defects and their effect on the radiation hardness of PbWO4 the current study is aimed at the melt composition infringements during its evaporation and at optical transmission of crystals obtained in these conditions after their irradiation (137Cs source). In the optical transmission measurements along with traditional techniques a method "in situ" was used, which provided the measurements in fixed points of the spectrum (380, 470 and 535 nm) directly in the process of the irradiation. X-ray phase and fluorescence analysis of condensation products of vapours over PbWO4 melt has found PbWO4 phase in their content as well as compounds rich in lead, PbO, Pb2WO5, with overall ratio Pb/W = 3.2. Correspondingly the lack of lead and variations in th...

  12. Normal coordinate treatment and Raman intensity analysis of yttrium vanadate and calcium tungstate crystal

    Energy Technology Data Exchange (ETDEWEB)

    Budha Addepalli, V; Kumar, S P; Padma, V A; Rajeswara Rao, N [Osmania Univ., Hyderabad (India). Dept. of Physics

    1976-09-01

    Raman scattering tensors of crystalline YVO/sub 4/ and CaWO/sub 4/ are derived. Using the spectra of YVO/sub 4/, the intensities are substituted in the formulae. They are used to determine the polarizability derivatives of V-O bond. Substituting them back into the intensity formulae, a number of equations involving the L elements are obtained. Supplementing them with the matrix equation LL' = G, and using L'FL = ..gamma.., a-l the F-elements are determined. It is observed that the force constants relating to the translations of the group YVO/sub 4/ are quite high, explaining the high melting point of the crystal.

  13. Design, status and test of the Mu2e crystal calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Martini, Matteo; et al.

    2016-06-17

    The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.

  14. Random lasing in Nd{sup 3+} doped potassium gadolinium tungstate crystal powder

    Energy Technology Data Exchange (ETDEWEB)

    Moura, André L., E-mail: andre.moura@fis.ufal.br [Grupo de Física da Matéria Condensada, Núcleo de Ciências Exatas – NCEx, Campus Arapiraca, Universidade Federal de Alagoas, 57309-005, Arapiraca, AL (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Fewo, Serge I. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Laboratory of Mechanics, Department of Physics, University of Yaoundé I, Yaoundé (Cameroon); Carvalho, Mariana T.; Gomes, Anderson S. L.; Araújo, Cid B. de [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Kuzmin, Andrey N.; Prasad, Paras N. [Institute for Lasers, Photonics and Biophotonics, The State University of New York, Buffalo, New York 14260-3000 (United States)

    2015-02-28

    Random laser (RL) emission in Nd{sup 3+} doped potassium gadolinium tungstate—KGd(WO{sub 4}){sub 2}:Nd{sup 3+}—crystal powder is demonstrated. The powder was excited at 813 nm in resonance with the Nd{sup 3+} transition {sup 4}I{sub 9/2}→{sup 4}F{sub 5/2}. RL emission at 1067 nm due to the {sup 4}F{sub 3/2}→{sup 4}I{sub 11/2} transition was observed and characterized. An intensity threshold dependent on the laser spot area and bandwidth narrowing from ≈2.20 nm to ≈0.40 nm were observed and measured. For a beam spot area of 0.4 mm{sup 2}, a RL threshold of 6.5 mJ/mm{sup 2} (90 MW/cm{sup 2}) was determined. For excitation intensity smaller than the RL threshold, only spontaneous emission from level {sup 4}F{sub 3/2} with decay time in the tens microsecond range was observed, but for excitation above the RL threshold, significant shortening of excited level lifetime, characteristic of a stimulated process was found. The overall characteristics measured show that KGd(WO{sub 4}){sub 2}:Nd{sup 3+} is an efficient material for operation of solid state RLs in the near-infrared.

  15. Synthesis, crystal structure and luminescent properties of a new pyrochlore type tungstate CsGa0.333W1.667O6

    Science.gov (United States)

    Zhao, Dan; Zhao, Ji; Fan, Yun-Chang; Ma, Zhao; Zhang, Rui-Juan; Liu, Bao-Zhong

    2018-06-01

    High temperature solution reaction leads to a new tungstate compound CsGa0.333W1.667O6, whose structure was determined by single-crystal X-ray diffraction analysis. The results show that it crystallizes in pyrochlore structure with cubic space group Fd-3m and a = 10.2529 (13) Å. In this structure, Ga and W atoms are in a statistical disorder manner. The self-activated luminescent properties CsGa0.333W1.667O6 were studied. Under the excitation of 323 nm, the emission spectrum exhibits a blue emission centered at 466 nm with the chromaticity coordinates (0.1838, 0.1814).

  16. Periodic position dependence of the energy measured in the CMS electromagnetic calorimeter

    CERN Document Server

    Descamps, Julien

    2006-01-01

    A uniform energy measurement response of the CMS electromagnetic calorimeter ECAL is essential for precision physics at the LHC. The ECAL barrel calorimeter consists of 61200 lead tungstate crystals arranged in a quasi-projective geometry. The energy of photons reaching the ECAL will be reconstructed by summing the channels corresponding to matrices of 3x3 or 5x5 crystals centred on the crystal with the largest energy deposit. The energy measured using such matrices of fixed size has been studied using electron test beam data taken in 2004. The variation of the energy containment with the incident electron impact position on the central crystal leads to a degradation of the energy resolution. A method using only the calorimeter information is presented to correct for the position dependent response. After correction, the energy resolution performance for uniform impact distributions of the electrons on the front face of a crystal approaches that obtained for maximal containment with a central impact. The univ...

  17. Assessing the performance under ionising radiation of lead tungstate scintillators for EM calorimetry in the CLAS12 Forward Tagger

    Science.gov (United States)

    Fegan, S.; Auffray, E.; Battaglieri, M.; Buchanan, E.; Caiffi, B.; Celentano, A.; Colaneri, L.; D`Angelo, A.; De Vita, R.; Dormenev, V.; Fanchini, E.; Lanza, L.; Novotny, R. W.; Parodi, F.; Rizzo, A.; Sokhan, D.; Tarasov, I.; Zonta, I.

    2015-07-01

    The well-established technology of electromagnetic calorimetry using Lead Tungstate crystals has recently seen an upheaval, with the closure of one of the most experienced large-scale suppliers of such crystals, the Bogoroditsk Technical Chemical Plant (BTCP), which was instrumental in the development of mass production procedures for PWO-II, the current benchmark for this scintillator. Obtaining alternative supplies of Lead Tungstate crystals matching the demanding specifications of contemporary calorimeter devices now presents a significant challenge to detector research and development programmes. In this paper we describe a programme of assessment carried out for the selection, based upon the performance under irradiation, of Lead Tungstate crystals for use in the Forward Tagger device, part of the CLAS12 detector in Hall B at Jefferson Lab. The crystals tested were acquired from SICCAS, the Shanghai Institute of Ceramics, Chinese Academy of Sciences. The tests performed are intended to maximise the performance of the detector within the practicalities of the crystal manufacturing process. Results of light transmission, before and after gamma ray irradiation, are presented and used to calculate dk, the induced radiation absorption coefficient, at 420 nm, the peak of the Lead Tungstate emission spectrum. Results for the SICCAS crystals are compared with identical measurements carried out on Bogoroditsk samples, which were acquired for the Forward Tagger development program before the closure of the facility. Also presented are a series of tests performed to determine the feasibility of recovering radiation damage to the crystals using illumination from an LED, with such illumination available in the Forward Tagger from a light monitoring system integral to the detector.

  18. Assessing the performance under ionising radiation of lead tungstate scintillators for EM calorimetry in the CLAS12 Forward Tagger

    Energy Technology Data Exchange (ETDEWEB)

    Fegan, S., E-mail: fegan@ge.infn.it [Istituto Nazionale di Fisica Nucleare, Sezione di Genova and Dipartimento di Fisica dell' Universitá, Via Dodecaneso 33, 16146 Genova (Italy); Auffray, E. [CERN, European Organisation for Nuclear Research, Geneva (Switzerland); Battaglieri, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova and Dipartimento di Fisica dell' Universitá, Via Dodecaneso 33, 16146 Genova (Italy); Buchanan, E. [University of Glasgow, Glasgow G12 8QQ (United Kingdom); Caiffi, B.; Celentano, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova and Dipartimento di Fisica dell' Universitá, Via Dodecaneso 33, 16146 Genova (Italy); Colaneri, L.; D' Angelo, A. [Istituto Nazionale di Fisica Nucleare, Sezione Roma2 Tor Vergata and Università degli studi di Roma Tor Vergata, Via Scientifica 1, 00133 Roma (Italy); De Vita, R. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova and Dipartimento di Fisica dell' Universitá, Via Dodecaneso 33, 16146 Genova (Italy); Dormenev, V. [II. Physikalisches Institut, Universität Gießen, 35392 Gießen (Germany); Fanchini, E. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova and Dipartimento di Fisica dell' Universitá, Via Dodecaneso 33, 16146 Genova (Italy); Lanza, L. [Istituto Nazionale di Fisica Nucleare, Sezione Roma2 Tor Vergata and Università degli studi di Roma Tor Vergata, Via Scientifica 1, 00133 Roma (Italy); Novotny, R.W. [II. Physikalisches Institut, Universität Gießen, 35392 Gießen (Germany); and others

    2015-07-21

    The well-established technology of electromagnetic calorimetry using Lead Tungstate crystals has recently seen an upheaval, with the closure of one of the most experienced large-scale suppliers of such crystals, the Bogoroditsk Technical Chemical Plant (BTCP), which was instrumental in the development of mass production procedures for PWO-II, the current benchmark for this scintillator. Obtaining alternative supplies of Lead Tungstate crystals matching the demanding specifications of contemporary calorimeter devices now presents a significant challenge to detector research and development programmes. In this paper we describe a programme of assessment carried out for the selection, based upon the performance under irradiation, of Lead Tungstate crystals for use in the Forward Tagger device, part of the CLAS12 detector in Hall B at Jefferson Lab. The crystals tested were acquired from SICCAS, the Shanghai Institute of Ceramics, Chinese Academy of Sciences. The tests performed are intended to maximise the performance of the detector within the practicalities of the crystal manufacturing process. Results of light transmission, before and after gamma ray irradiation, are presented and used to calculate dk, the induced radiation absorption coefficient, at 420 nm, the peak of the Lead Tungstate emission spectrum. Results for the SICCAS crystals are compared with identical measurements carried out on Bogoroditsk samples, which were acquired for the Forward Tagger development program before the closure of the facility. Also presented are a series of tests performed to determine the feasibility of recovering radiation damage to the crystals using illumination from an LED, with such illumination available in the Forward Tagger from a light monitoring system integral to the detector.

  19. Contribution to the study of the readout of the electromagnetic calorimeter crystals in the CMS experiment at LHC; Contribution a l`etude de la lecture des cristaux du calorimetre electromagnetique de l`experience CMS au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Franck [Universite Claude Bernard Lyon-1, 69 - Lyon (France)

    1998-07-03

    The search for neutral Higgs boson through its decay into two photons provides a very promising signal for a mass between 90 and 150 GeV. It requires an electromagnetic calorimeter of very high resolution. The CMS (Compact Muon Solenoid) electromagnetic calorimeter must be made up of more than 80,000 lead tungstate crystals. In the central part (the barrel), the scintillation light readout is performed by means of avalanche photodiodes, a silicon photo-sensor with internal gain which is a relative novelty in high energy physics. Concerning the readout electronics, the energy available in the centre-of-mass (14 TeV) as well as the collision frequency (40 MHz) of LHC impose constraints with respect to the signal treatment up to the acquisition. The retained solution consists in pairing two avalanche photodiodes, the parameters of which (gain, temperature dependence, dark current, etc) must be controlled, and coupling them to a low noise preamplifier of high dynamical range (5 MeV - 2 TeV) followed by a four-slopes linear compressor and a analog-digital sampling converter of 12 bits, 40 MHz. The thesis presents the prototypes of different electromagnetic calorimeters tested in the high energy beam. An energy resolution of 0.6% at 100 GeV was obtained with a conventional readout circuitry, while the integrated associated circuits were radiation resistant 73 refs., 100 figs., 19 tabs.

  20. Cosmic ray calibration of the PbWO4 crystal electromagnetic calorimeter of CMS

    International Nuclear Information System (INIS)

    Franzoni, G.

    2006-01-01

    The Compact Muon Solenoid experiment at the CERN LHC features a high precision PbWO4 crystal electromagnetic calorimeter. Each crystal is first precalibrated with a radioactive source and by means of optical measurements. After the assembly, each supermodule (1700 crystals) is exposed to comics rays.The comparison between intercalibration obtained from cosmic muons and electrons from test beam was performed at the end of 2004 for an initial set of 130 channels and showed that a precalibration with a statistical precision of 1 to 2% can be achieved within approximately one week. An important aspect of the comics muons analysis is that it is entirely based on the calorimeter data, without using any external tracking device.We will present the setup and results from the 2004 test as well as recent data recorded on many supermodule

  1. Precision machining and polishing of scintillating crystals for large calorimeters and hodoscopes

    International Nuclear Information System (INIS)

    Wuest, C.R.; Fuchs, B.A.; Holdener, F.R.; Heck, J.L. Jr.

    1994-04-01

    New machining and polishing techniques have been developed for large scintillating crystal arrays such as the Barium Fluoride Electromagnetic Calorimeter for the GEM Detector at SSCL, the Crystal Clear Collaboration's cerium fluoride or lead tungstenate calorimeter at the proposed LHC and CERN, the PHENIX Detector at RHIC (barium fluoride), and the cesium iodide Calorimeter for the BaBar Detector at PEP-2 B Factory at SLAC. The machining and polishing methods to be presented in this paper provide crystalline surfaces without sub-surface damage or deformation as verified by Rutherford Back-scattering (RBS) analysis. Surface roughness of about 10--20 angstroms and sub-micron mechanical tolerances have been demonstrated on large barium fluoride crystal samples. Mass production techniques have also been developed for machining the proper angled surfaces and polishing up to five 50 cm long crystals at one time. These techniques utilize kinematic mount technology developed at LLNL to allow precision machining and polishing of complex surfaces. They will present this technology along with detailed surface studies of barium fluoride and cerium fluoride crystals polished with this technique

  2. The LYSO crystal calorimeter for the Mu2e experiment

    International Nuclear Information System (INIS)

    Pezzullo, G; Cervelli, F; Budagov, J; Davydov, Yu; Glagolev, V; Carosi, R; Cheng, C; Echenard, B; Hitlin, D; Ongmonkolkul, P; Porter, F; Cordelli, M; Corradi, G; Giovannella, S; Happacher, F; Luca, A; Martini, M; Miscetti, S; Saputi, A; Murat, P

    2014-01-01

    The Mu2e experiment at Fermilab searches the neutrino-less conversion of the muon into electron in the field of an Aluminum nucleus. If such a process will be observed, it will be a proof of the charged-lepton-flavor-violation (cLFV), otherwise Mu2e will set an upper limit of R μe < 6 × 10 −17 @ 90% C.L. (which represents an improvement by 3–4 order of magnitude over the existing limit). The Mu2e detector apparatus consists of a magnetic spectrometer, devoted to the measurement of the electrons momentum, and an electromagnetic calorimeter (EMC) which provides an independent measurement of the electron energy, time and position, used for validating or rejecting candidate tracks selected by the tracking system. In this paper, we describe the baseline project of the EMC and present results in terms of performances and R and D

  3. Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter

    CERN Document Server

    Auffray, Etiennette; Freire, M; Lecoq, P; Le Goff, J M; Marcos, R; Drobychev, G Yu; Missevitch, O V; Oskine, A; Zouevski, R F; Peigneux, J P; Schneegans, M

    2001-01-01

    Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs).

  4. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  5. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  6. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  7. Polarimetry concept based on heavy crystal hadron calorimeter

    Science.gov (United States)

    Keshelashvili, I.; Müller, F.; Mchedlishvili, D.; JEDI Collaboration

    2017-11-01

    In the ongoing JEDI (Jülich Electric Dipole moment Investigations) project, the essential point will be to measure a tiny beam polarization change over an extended period of time. The particle scarcity in the polarized deuteron or proton beams and the required slow extraction rate puts tough experimental constrains on the polarimetry. For the EDM measurements, a dedicated high precision polarimeter is required. To fulfill specifications, a fast, dense, high resolution (energy and time), and radioactive hard novel crystal scintillating material is required. LYSO crystals are supposed to be used as an ideal scintillating material for this kind of detector. The LYSO crystal PMT and SiPM readout, with a FADC based system is under development. The first proton and deuteron beam test of the prototypes are presented here. In this paper, the new polarimetry concept and preliminary results from first proton and deuteron beam time are presented.

  8. Design, status and perspective of the Mu2e crystal calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Pezzullo, G. [INFN sezione di Pisa (Italy); Atanov, N. [Joint Institute for Nuclear Research, Dubna (Russia); Baranov, V. [Joint Institute for Nuclear Research, Dubna (Russia); Budagov, J. [Joint Institute for Nuclear Research, Dubna (Russia); Cervelli, F. [INFN sezione di Pisa (Italy); Colao, F. [INFN Laboratori Nazionali di Frascati (Italy); Diociaiuti, E. [INFN Laboratori Nazionali di Frascati (Italy); Cordelli, M. [INFN Laboratori Nazionali di Frascati (Italy); Dane, E. [INFN Laboratori Nazionali di Frascati (Italy); Davydov, Yu. [Joint Institute for Nuclear Research, Dubna (Russia); Donati, S. [Univ. of Pisa (Italy); INFN sezione di Pisa (Italy); Donghia, R. [INFN Laboratori Nazionali di Frascati (Italy); Di Falco, S. [INFN sezione di Pisa (Italy); Echenard, B. [California Inst. of Technology (CalTech), Pasadena, CA (United States). Departement of Physics; Morescalchi, L. [INFN sezione di Pisa (Italy); Giovannella, S. [INFN Laboratori Nazionali di Frascati (Italy); Glagolev, V. [Joint Institute for Nuclear Research, Dubna (Russia); Grancagnolo, F. [INFN sezione di Lecce (Italy); Happacher, F. [INFN Laboratori Nazionali di Frascati (Italy); Hitlin, D. [California Inst. of Technology (CalTech), Pasadena, CA (United States). Departement of Physics; Martini, M. [INFN Laboratori Nazionali di Frascati (Italy); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Miscetti, S. [INFN Laboratori Nazionali di Frascati (Italy); Miyashita, T. [California Inst. of Technology (CalTech), Pasadena, CA (United States). Departement of Physics; Murat, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Pedreschi, E. [INFN sezione di Pisa (Italy); Porter, F. [California Inst. of Technology (CalTech), Pasadena, CA (United States). Departement of Physics; Raffaelli, F. [INFN sezione di Pisa (Italy); Ricci, M. [INFN Laboratori Nazionali di Frascati (Italy); Saputi, A. [INFN Laboratori Nazionali di Frascati (Italy); Sarra, I. [INFN Laboratori Nazionali di Frascati (Italy); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Spinella, F. [INFN sezione di Pisa (Italy); Tassielli, G. [INFN sezione di Lecce (Italy); Tereshchenko, V. [Joint Institute for Nuclear Research, Dubna (Russia); Zhu, R. Y. [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    2018-01-09

    The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $\\mu \\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $\\mu$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. Here, in this paper we present the calorimeter design and the latest R&D results.

  9. An automatic device for the quality control of large-scale crystal's production

    CERN Document Server

    Baccaro, S; Castellani, M; Cecilia, A; Dafinei, I; Diemoz, M; Guerra, S; Longo, E; Montecchi, M; Organtini, G; Pellegrini, F

    2001-01-01

    In 1999, the construction of the electromagnetic calorimeter of the Compact Muon Solenoid (CMS) experiment started. Half of the barrel calorimeter made of 61200 lead tungstate (PWO) crystals will be assembled and tested in the Regional Centre of INFN-ENEA in Rome, Italy. Before assembling, all 30600 PWO crystals will be qualified for scintillation and radiation hardness characteristics by a specially built Automatic Crystal Control System. The measuring techniques for crystal qualification and performances of the automatic system will be discussed in this work. (11 refs).

  10. An FPGA-based Sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. The Crystal Barrel Calorimeter has been upgraded replacing its photodiode readout by APDs, which allows the integration of the calorimeter into the first level trigger. Since the possible DAQ rate is currently limited by the digitization stage (LeCroy QDC1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is the second important step in the upgrade of the detector system. Based on the 64-channel PANDA-SADC, the design was modified, adapting it to the needs of the CBELSA/TAPS experiment. The CB-SADC offers 64 channels in one NIM module with up to 14 bit rate at 125 MHz, accompanied by a modular analog input stage and power supply. Data processing and reduction are realized with Kintex7 FPGAs. Readout is possible via gigabit ethernet links. Using an FPGA provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery. The SADC development is discussed, and first measurements performed in comparison to the presently used LeCroy QDC are presented.

  11. Performance of a PbWO sub 4 crystal calorimeter for 0.2-1.0 GeV electrons

    CERN Document Server

    Shimizu, H; Hashimoto, T; Abe, K; Asano, Y; Kinashi, T; Matsumoto, T; Matsumura, T; Okuno, H; Yoshida, H Y

    2000-01-01

    The performance of a calorimeter prototype of PbWO sub 4 crystals has been tested by using 0.2-1.0 GeV electrons. The calorimeter comprises nine crystals, each 20 mmx20 mmx200 mm, arranged in a 3x3 matrix. A phototube was connected to each crystal to collect the signal. The energy resolution is obtained to be (sigma/E) sup 2 =((0.014+-0.001)/E) sup 2 +((0.025+-0.001)/sq root E) sup 2 +(0.000+-0.027) sup 2 at 13 deg. C, where E is the energy given in GeV. The position of the incident electron beam has been measured every 2 mm step. The position resolution at the center of the crystal is obtained to be sq root((2.6+-0.1)/sq root E) sup 2 +(0.4+-0.6) sup 2 mm.

  12. Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Vesztergombi, Gyorgy; Zálán, Peter; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sudhakar, Katta; Verma, Piyush; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Mescheryakov, G; Sergeyev, S; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Stolin, Viatcheslav; Ulyanov, A; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Kuzucu-Polatoz, A; Onengüt, G; Ozdes-Koca, N; Cankocak, Kerem; Ozok, Ferhat; Serin-Zeyrek, M; Sever, Ramazan; Zeyrek, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grinev, B; Lubinsky, V; Senchishin, V; Anderson, E Walter; Hauptman, John M; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Lazic, Dragoslav; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Antchev, Georgy; Hazen, Eric; Lawlor, C; Machado, Emanuel; Posch, C; Rohlf, James; Wu, Shouxiang; Adams, Mark Raymond; Burchesky, Kyle; Qiang, W; Abdullin, Salavat; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumu, K; Thomas, Ray; Baarmand, Marc M; Ralich, Robert; Vodopiyanov, Igor; Cushman, Priscilla; Heering, Arjan Hendrix; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Mans, Jeremy; Tully, Christopher; De Barbaro, Pawel; Bodek, Arie; Budd, Howard; Chung, Yeon Sei; Haelen, T; Imboden, Matthias; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T; Pompos, Arnold

    2007-01-01

    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%.

  13. Construction and beam test of a small compact electromagnetic PbWO4 calorimeter

    International Nuclear Information System (INIS)

    Feller, R.P.; Gendner, N.; Holm, U.; Johnson, K.F.; Meyer-Larsen, A.; Thies, S.

    2002-01-01

    A compact homogenous electromagnetic calorimeter with an energy resolution of better than 5%/√E/GeV, made out of lanthanum-doped lead tungstate crystals from Bogoroditsk, Russia, has been built for use in the ZEUS detector. The whole calorimeter, composed of 4x4 crystals, each of dimensions 23.8x23.8x200 mm 3 , light guides and photomultipliers, fits into a space of 12x12x27 cm 3 . Beam tests with electrons up to 100 GeV showed an energy resolution of better than 4.9%/√E/GeV, a linearity of better than 1% and a position resolution of 1.1 mm. The influence of temperature variations and recovery of an irradiated crystal on the total energy signal could be corrected to better than 1%. EGS4 simulations reproduce the results very well

  14. A new avalanche photo diode based readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Urban, Martin [Helmholtz-Institut fuer Strahlen- und Kernphysik, Nussallee 14-16, 53115 Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2015-07-01

    The CBELSA/TAPS experiment at ELSA has proven successful in the measurement of double polarization observables in meson photoproduction off protons and neutrons. To be able to measure purely neutral reactions on a polarized neutron target with high efficiency, the main calorimeter consisting of 1320 CsI(Tl) crystals has to be integrated into the first level trigger. Key requirement to achieve this goal is an exchange of the existing PIN photo diode by a new avalanche photo diode (APD) readout. The main advantage of the new readout system is that it will provide timing information which allows a fast trigger signal. The energy resolution will remain compatible to the previous system. Besides the development of automated test routines for the front end electronics, the characterization of all APDs was successfully accomplished in Bonn. After tests with a 3 x 3 CsI(Tl) crystal matrix at the tagged photon beam facilities at ELSA and MAMI the first half of the Crystal Barrel was upgraded in 2014. This talk shows the result of the latest test measurements including the gain stabilization of the new APD readout electronics and presents the progress of the ongoing upgrade.

  15. An FPGA-based sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2015-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. Presently the readout of the CsI(Tl)-crystals of the Crystal Barrel calorimeter is being upgraded from a PIN-diode readout to an APD readout to create a fast signal for first-level-triggering. This will increase the trigger efficiency especially for final states with only neutral particles substantially. To increase the possible data readout rate, which is currently limited by the digitization stage (LeCroy QDC 1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is being prepared. Based on the 64-channel PANDA-SADC, the CB-SADC design was modified and adapted to the needs of the CBELSA/TAPS experiment. It offers 64 channels in one NIM module, together with modular analog or FPGA-based digital shaping. The data transfer will be realized by two standard gigabit links. Using an FPGA together with SADCs provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery.

  16. Measurement of the Muon Stopping Power in Lead Tungstate

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G.; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in lead tungstate is measured to be 160+5/-6 plus or minus 8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy.

  17. The CMS Electromagnetic Calorimeter: Results on Crystal Measurements, Quality Control and Data Management in the Rome Regional Center

    CERN Document Server

    Costantini, S

    2004-01-01

    The barrel of the CMS electromagnetic calorimeter is currently under construction and will contain 61200 PbWO4 crystals. Half of them are being fully characterized for dimensions, optical properties and light yield in the INFN-ENEA Regional Center near Rome. We describe the setup of an automatic quality control system for the crystal measurements and the present results on their qualification, as well as the REDACLE project, which has been developed to control and ease the production process. As it will not be possible to precalibrate the whole calorimeter,the crystal measurements and quality checks performed at the Regional Center will be crucial to provide a basis for fast in-situ calibration with particles. REDACLE is at the same time a fast database and a data management system, where the database and the workflow structures are decoupled, in order to obtain the best flexibility.

  18. Influence of variable tungsten valency on optical transmittance and radiation hardness of lead tungstate (PWO) scintillation crystals

    CERN Document Server

    Burachas, S; Makov, I; Saveliev, Yu; Ippolitov, M S; Man'ko, V; Nikulin, S P; Nyanin, A; Vasilev, A; Apanasenko, A; Tamulaitis, G

    2003-01-01

    A new approach to interpret the radiation hardness of PbWO//4 (PWO) scintillators is developed by revealing importance of the inclusions of tungsten oxides WO//3//-//x with variable valency. It is demonstrated that the influence of the ionizing radiation on PWO is, in many aspects, similar to the effect of the high-temperature annealing in oxygenless ambient. In both cases, a valency change of the tungsten oxides is initiated and results in induced absorption and, consequently, in crystal coloration. In the PWO crystals doped with L//2O//3 (L = Y, La, Gd), the radiation hardness and the optical properties are mainly affected by inclusions of W//1//-//yL//yO//3//- //x (0 less than x less than 0.3) instead of inclusions of WO//3//- //x prevailing in the undoped samples. It is demonstrated that the radiation-induced bleaching and the photochromic effect of PWO are caused by phase transitions in the inclusions of tungsten oxide. Thermodynamic conditions for the phase transitions are discussed and the optimal oxid...

  19. Highly phosphorescent hollow fibers inner-coated with tungstate nanocrystals

    Science.gov (United States)

    Ng, Pui Fai; Bai, Gongxun; Si, Liping; Lee, Ka I.; Hao, Jianhua; Xin, John H.; Fei, Bin

    2017-12-01

    In order to develop luminescent microtubes from natural fibers, a facile biomimetic mineralization method was designed to introduce the CaWO4-based nanocrystals into kapok lumens. The structure, composition, and luminescence properties of resultant fibers were investigated with microscopes, x-ray diffraction, thermogravimetric analysis, and fluorescence spectrometry. The yield of tungstate crystals inside kapok was significantly promoted with a process at high temperature and pressure—the hydrothermal treatment. The tungstate crystals grown on the inner wall of kapok fibers showed the same crystal structure with those naked powders, but smaller in crystal size. The resultant fiber assemblies demonstrated reduced phosphorescence intensity in comparison to the naked tungstate powders. However, the fibers gave more stable luminescence than the naked powders in wet condition. This approach explored the possibility of decorating natural fibers with high load of nanocrystals, hinting potential applications in anti-counterfeit labels, security textiles, and even flexible and soft optical devices.

  20. Development of an event builder for the new SADC-readout of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Schultes, Jan; Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA in Bonn investigates the photoproduction of mesons off nucleons. Presently the readout of the CsI(Tl)-crystals of the Crystal Barrel calorimeter is being upgraded from a PIN-diode readout to an APD readout to create a fast signal for first-level-triggering. Furthermore, an entirely new setup consisting of Sampling-ADCs (SADC) with FPGA-based readout is being prepared to increase the possible data rate achievable. The SADC is capable of sampling pulses from the detector with 80 MHz, extracting features by FPGA-logic and transferring this data via UDP. To improve package-handling, a server-client structure will be provided. It is foreseen to receive packages from each of the 48 SADC units (32 channels each), detect and handle possible package losses, distribute the received information further via TCP and control the SADC-behaviour. In addition and to assist the FPGA firmware development, a tool to monitor outgoing pulses and to extract important features, such as the deposited energy, timing information and pile-up detection to cross-check the information given by the FPGA is being developed.

  1. Study of the optical monitoring system of the scintillating crystal involved in the electromagnetic calorimeter of CMS experiment

    International Nuclear Information System (INIS)

    Geleoc, M.

    1998-01-01

    The prospect of the experimental discovery of the Higgs boson is one of the motivations to build the large hadron collider (LHC). Proton beams will collide and the emitted particles will be detected by ATLAS and CMS equipment. In each detector the electromagnetic calorimeter will allow the characterisation of the 2 photons coming from one of the disintegration channels of the Higgs boson. CMS collaboration has chosen an homogeneous calorimeter fitted with PbWO 4 crystals. Each crystal with its photodetector and its electronic device forms one detection channel. The resolution of the detection channels should not deteriorate all along the operating time. The optical monitoring system of the crystals logs then controls the response of each detection channel in order to allow an accurate calibration of the calorimeter. The optical properties, the resistance to irradiation of PbWO 4 crystals and the modelling of light collection are investigated in this work. The description of the different components of the optical monitoring system highlights the technical difficulties we had to challenge. An experimental testing bench has been set up to study the coupling between the scintillation signal and the signal that feeds the monitoring system, this coupling has been studied under irradiation in the conditions of CMS operating. (A.C.)

  2. Search for and selection of novel heavy scintillator crystals for calorimeter design for future high-energy colliders

    International Nuclear Information System (INIS)

    Ferrere, D.

    1993-01-01

    The discovery of some particles (Higgs, top,..) foreseen by theoretical models should be achieved at future colliders allowing to reach an energy scale of about 1 TeV. Efficient detectors must be designed to handle the very high luminosity of the LHC collider at CERN. In the intermediate mass region, M Z -2M Z , the diphoton decay mode of a Higgs boson produced inclusively or in association with W boson or a toponium gives good chance of observation. A very high resolution calorimeter with photon angle reconstruction and pion identification capability should detect a Higgs signal with high probability. So a homogeneous crystal calorimeter seems to be suitable. Because of the high luminosity and the high radiation level, a search for a new heavy scintillator has been undertaken. It must have a good radiation hardness (>0.5 MRad in a year) and a fast luminescence decay time (<30 ns). Among 50 crystals or glasses of specific chemical composition tested in transmission, luminescence, decay time, γ/neutrons radiation and light yield, cerium fluoride seems best suited for LHC. The necessity to have a good photon resolution in the intermediate Higgs mass region led us to optimise by Monte Carlo simulations the geometry of the calorimeter, the uniformisation of the light collection and crystal intercalibration parameters. (orig.)

  3. Prospects for a precision timing upgrade of the CMS PbWO crystal electromagnetic calorimeter for the HL-LHC

    CERN Document Server

    Massironi, Andrea

    2017-01-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies focused on the timing properties of PbWO$_4$ crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies intended to measure the timing performance of the PbWO$_4$ crystals with different photosensors and readout electronics will be shown.

  4. Prospects for a precision timing upgrade of the CMS PbWO crystal electromagnetic calorimeter for the HL-LHC

    Science.gov (United States)

    Massironi, A.

    2018-04-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies focused on the timing properties of PbWO4 crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies intended to measure the timing performance of the PbWO4 crystals with different photosensors and readout electronics will be shown.

  5. Studies on an automated gain stabilisation for the new APD read-out of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Pauli, Peter [HISKP Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    For the investigation of the nucleon spectrum it is not enough to measure only cross sections because of the large overlap of resonances. To disentangle these resonances, a partial wave analysis is needed. To find unambiguous solutions it is necessary to measure (double) polarisation observables. The CBELSA/TAPS experiment is an important tool to measure these observables in meson photoproduction off nucleons. To achieve a high efficiency in purely neutral reactions it is important to implement the main calorimeter into the first level trigger. To do so it is necessary to replace the current PIN photo diodes with new avalanche photo diodes (APDs). The new read-out is able to provide a timing signal that is fast enough to use it as a trigger while it does not impair the energy resolution of the calorimeter compared to the previous system. A drawback of APDs is their temperature dependency. To provide a stable gain throughout varying running conditions it is vital to monitor the temperature change and correct it if necessary. The poster shows an approach to ensure temperature stability where the temperature is monitored via a temperature sensitive NTC thermistor and the gain is adjusted via changes of the high voltage supply of the APDs. This method proved successful while it is easy to implement in all 1320 CsI(Tl) crystals of the calorimeter.

  6. Synthesis of cadmium tungstate films via sol-gel processing

    Energy Technology Data Exchange (ETDEWEB)

    Lennstrom, Kirk; Limmer, Steven J.; Cao Guozhong

    2003-06-23

    Cadmium tungstate is a scintillator material with excellent intrinsic photoluminescent properties. It is highly resistant to gamma radiation, has an almost non-existent afterglow and is highly efficient. Cadmium tungstate is also non-hydroscopic, unlike the more prevalent thallium-doped alkali halide scintillators. In order to create thin films of cadmium tungstate with precise stoichiometric control, a sol-gel processing technique has been applied to produce this material for the first time. In addition to lower processing temperatures, sol-gel-derived cadmium tungstate is cheaper and easier than other technologies, particularly for thin films. Furthermore, it has the potential to produce nanostructured materials with good optical quality. X-Ray diffraction results of sol-gel-derived materials fired at various temperatures imply crystallization of cadmium tungstate without the intermediate formation of either tungsten oxide or cadmium oxide. Scanning electron microscopy analysis shows the formation of nano-sized particles prior to heat treatment, which form meso-sized particles after the heat treatment. Photoluminesce analysis indicates emission of derived films at 480 nm, which agrees with other published data. Finally, the efficiency of derived films was approximately 6%{+-}1.8%.

  7. Quality inspection of anisotropic scintillating crystals through measurement of interferometric fringe pattern parameters

    CERN Document Server

    Cocozzella, N; Majni, G; Paone, N; Rinaldi, D T

    2001-01-01

    Scintillating crystals are widely used as detectors in radiographic systems, computerized axial tomography devices and in calorimeters employed in high-energy physics. This paper results from a project motivated by the development of the CMS calorimeter at CERN, which will make use of a large number of scintillating crystals. In order to prevent crystals from breaking because of internal residual stress, a quality control system based on optic inspection of interference fringe patterns was developed. The principle of measurement procedures was theoretically modelled, and then a dedicated polariscope was designed and built, in order to observe the crystals under induced stresses or to evaluate the residual internal stresses. The results are innovative and open a new perspective for scintillating crystals quality control: the photoelastic constant normal to the optic axis of the lead tungstate crystals (PbWO sub 4) was measured, and the inspection procedure developed is applicable to mass production, not only t...

  8. Radiation hardness test of un-doped CsI crystals and Silicon Photomultipliers for the Mu2e calorimeter

    Science.gov (United States)

    Baccaro, S.; Cemmi, A.; Cordelli, M.; Diociaiuti, E.; Donghia, R.; Giovannella, S.; Loreti, S.; Miscetti, S.; Pillon, M.; Sarra, I.

    2017-11-01

    The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that, in the hottest regions, each crystal will absorb a dose of 300 Gy and will be exposed to a neutron fluency of 6 × 1011 n/cm2 in 3 years of running. Test of un-doped CsI crystals irradiated up to 900 Gy and to a neutron fluency up to 9 × 1011 n/cm2 have been performed at CALLIOPE and FNG ENEA facilities in Italy. We present our study on the variation of light yield (LY) and longitudinal response uniformity (LRU) of these crystals after irradiation. The ionization dose does not modify LRU while a 20% reduction in LY is observed at 900 Gy. Similarly, the neutron flux causes an acceptable LY deterioration (≤ 15%). A neutron irradiation test on different types of SIPMs (two different array models from Hamamatsu and one from FBK) have also been carried out by measuring the variation of the leakage current and the charge response to an ultraviolet led. We concluded that, in the experiment, we will need to cool down the SIPMs to 0 °C reduce the leakage current to an acceptable level.

  9. The construction of the CMS electromagnetic calorimeter: automatic measurements of the physics parameters of PWO crystals

    CERN Multimedia

    2005-01-01

    Crystal properties (dimensions, optical transmission, light yield) are automatically measured. The pictures show different measurement stations of the automatic machine. Crystals are measured on trays containing five crystals each.

  10. PANDA electromagnetic calorimeters

    International Nuclear Information System (INIS)

    Semenov, P.A.; Kharlov, Yu.V.; Uzunian, A.V.; Chernichenko, S.K.; Derevschikov, A.A.; Davidenko, A.M.; Goncharenko, Y.M.; Kachanov, V.A.; Konstantinov, A.S.; Kormilitsin, V.A.; Matulenko, Yu.A.; Meschanin, A.P.; Melnick, Y.M.; Minaev, N.G.; Mochalov, V.V.; Morozov, D.A.; Novotny, R.W.; Ryazantsev, A.A.; Soldatov, A.P.; Soloviev, L.F.

    2009-01-01

    PANDA is a challenging experimental setup to be implemented at the high-energy storage ring (HESR) at the international facility FAIR, GSI (Germany). PANDA physics program relies heavily on the capability to measure photons with excellent energy, position and timing resolution. For this purpose PANDA proposed to employ electromagnetic calorimeters using two different technologies: compact crystal calorimeter cooled to -25 deg. C around target and lead-scintillator sandwich calorimeter with optical fibers light collection (so-called shashlyk calorimeter) in the forward region. Institute for High Energy Physics (IHEP) PANDA group reports on two types of measurements performed at IHEP, Protvino: radiation hardness of the PWO crystals at -25 deg. C and testbeam studies of the energy and position resolution of the shashlyk calorimeter prototype in the energy range up to 19 GeV.

  11. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  12. Building a crystal palace

    CERN Multimedia

    2007-01-01

    The end-caps of the CMS electromagnetic calorimeter (ECAL) take shape as the first quadrant was completed on Wednesday 3 October. 1831 crystals, organised into five by five blocks named ‘supercrystals’, make up the first quadrant of Dee 1.With the 61,200-crystal barrel of its electromagnetic calorimeter (ECAL) complete, CMS is now building the endcaps, on the tenth anniversary of their initial design. Crystals for the endcaps were the last to be made, so the race is now on to have them all in place and ready for the turn-on of the LHC next year. Assembly of the first of eight quadrants began in June and crystal mounting was completed on Wednesday 3 October. Each crystal is transparent, has a volume just larger than a CERN coffee cup yet weighs a huge 1.5kg. 1831 of these lead tungstate crystals went into the first quadrant from a total 14,648 in the endcaps. The lead and tungsten account for 86% of each crystal’s weight, but as project leader Dave Cockerill expl...

  13. Studies of the electromagnetic calorimeter and direct photon production at the CMS detector

    International Nuclear Information System (INIS)

    Reid, E.C.

    1999-04-01

    This thesis describes work carried out on the Compact Muon Solenoid (CMS) experiment for the Large Hadron Collider at CERN. Studies of the prototype of the electromagnetic calorimeter are described. The energy resolution has been evaluated for the 7 x 7 lead tungstate crystal matrix . The energy resolution achieved was: σ/E = 4.5%/√E ± 0.31%. An investigation of the response of eight prototype crystals to irradiation is also presented. This thesis describes in detail the first study of direct photon production at CMS. Event simulation and methods of reducing the background to the direct photon signal are presented. This work demonstrates that this process may he used to distinguish between different parameterisations of the gluon distribution. The sensitivity is such that a few days worth of data taking at low luminosity will be sufficient for this type of analysis at CMS. (author)

  14. Prospects for a precision timing upgrade of the CMS PbWO$_{4}$ crystal electromagnetic calorimeter for the HL-LHC

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies on the timing properties of PbWO crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies on the timing performance of PbWO$_{4}$ crystals with various photosensors and readout electronics will be shown.

  15. Luminescence and photo-thermally stimulated defect-creation processes in Bi.sup.3+./sup.-doped single crystals of lead tungstate

    Czech Academy of Sciences Publication Activity Database

    Buryi, Maksym; Boháček, Pavel; Chernenko, K.; Krasnikov, A.; Laguta, Valentyn; Mihóková, Eva; Nikl, Martin; Zazubovich, S.

    2016-01-01

    Roč. 123, č. 5 (2016), 895-910 ISSN 0370-1972 R&D Projects: GA ČR GAP204/12/0805 Institutional support: RVO:68378271 Keywords : defects * EPR * excitons * PbWO 4 :Bi single crystals * photoluminescence * thermoluminescence Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.674, year: 2016

  16. Measurements and simulations on position dependencies in the response of single PWO crystals and a prototype for the $\\overline{P}ANDA$ EMC

    CERN Document Server

    Bremer, Daniel Andreas

    The PANDA experiment, which will be located at the future Facility for Antiproton and Ion Research, aims at the study of strong interaction within the charm sector via antiproton- proton collisions. An essential component of the PANDA detector to achieve the ambitious physics goals is the Electromagnetic Calorimeter (EMC). Reason for this is particularly its high detection efficiency for photons and electrons over a large dynamic range, since most of the expected physics channels are accompanied by secondary photons. The EMC is based on second generation lead tungstate scintillator crystals and thus features a very compact design and improved performance. To guarantee a homogeneous and precise energy and momentum response, an exact knowledge on the incident particle position is mandatory. In the scope of this work, non-uniformities in the light yield of single lead tungstate crystals with tapered geometry are investigated. This effect was studied with the SLitrani simulation package in comparison to a series ...

  17. Advanced Thin Ionization Calorimeter (ATIC)

    Science.gov (United States)

    Wefel, John P.

    1998-01-01

    This is the final report for NASA grant NAGW-4577, "Advanced Thin Ionization Calorimeter (ATIC)". This grant covered a joint project between LSU and the University of Maryland for a Concept Study of a new type of fully active calorimeter to be used to measure the energy spectra of very high energy cosmic rays, particularly Hydrogen and Helium, to beyond 1014 eV. This very high energy region has been studied with emulsion chamber techniques, but never investigated with electronic calorimeters. Technology had advanced to the point that a fully active calorimeter based upon Bismuth Germanate (BGO) scintillating crystals appeared feasible for balloon flight (and eventually space) experiments.

  18. The Mu2e crystal calorimeter and improvements in the $\\mu^-\\mbox{N} \\to e^-\\mbox{N}$ search sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Pezzullo, Gianantonio [Univ. of Pisa (Italy)

    2016-01-01

    The Mu2e experiment will search for Charged Lepton Flavor Violation (CLFV) looking at the conversion of a muon into an electron in the field of an aluminum nucleus. About $7\\cdot 10^{17}$ muons, provided by a dedicated muon beam line in construction at the Fermi National Accelarator Laboratory (Fermilab), will be stopped in 3 years in the Aluminum target. The corresponding single event sensitivity will be $2.5\\cdot 10^{-17}$. The Standard Model of particle physics, even extendend to include the finite neutrino masses, predicts the ratio Rμe between muon conversions and muon nuclear captures to be $\\sim 10^{- 52}$. Several extensions of the Standard Model predict Rμe to be in the range of $10^{-14} - 10^{-18}$. % The current best experimental limit, set by the SINDRUM II experiment is $7 \\cdot 10^{-13}$ @ $90\\%$ CL. The Mu2e experiment plans to improve this experimental limit by four order of magnitude to test many of the possible extensions of the Standard Model. To reach this ambitious goal, the Mu2e experiment is expected to use an intense pulsed muon beam, and rely on a detector system composed of a straw tube tracker and a calorimeter made of pure CsI crystals. The calorimeter plays a central role in the Mu2e measurement, providing particle identification capabilities that are necessary for rejecting two of the most dangerous background sources that can mimic the μ⁻N → e⁻N conversion electron: cosmic muons and $\\bar{p}$ induced background. The calorimeter information allows also to improve the tracking performance. Thanks to a calorimeter-seeded track finder algorithm, it is possible to increase the track reconstruction efficiency, and make it more robust with respect to the occupancy level. Expected performances of the calorimeter have been studied in a beam test at the Beam Test Facility in Frascati (Rome, Italy). A reduced scale calorimeter prototype has been exposed to an electron beam, with energy varying from 80 to 140

  19. Predicting the performance of the CMS precision PbWO$_4$ electromagnetic calorimeter in the HL-LHC era from test beam results on irradiated crystals

    CERN Document Server

    Zghiche, Amina

    2017-01-01

    The harsh radiation environment in which detectors will have to operate during the High Luminosity phase of the LHC (HL-LHC) represents a crucial challenge for many calorimeter technologies. In the CMS forward calorimeters, ionizing doses and hadron fluences will reach up to 300 kGy (at a dose rate of 30 Gy/h) and ${\\bf 2\\times 10^{14} cm^{-2}}$, respectively, at the pseudorapidity region of {\\bf $\\vert\\eta\\vert$}= 2.6. To evaluate the evolution of the CMS ECAL performance in such conditions, a set of \\PWO crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between ${\\bf 2.1\\times 10^{13} cm^{-2}}$ and ${\\bf 1.3\\times 10^{14} cm^{-2}}$, has been studied in beam tests. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The evolution of the performance of the PbWO$_4$ cry...

  20. Synthesis and characterization of nanophased silver tungstate

    Indian Academy of Sciences (India)

    nanoparticles were examined with scanning electron microscope (A Lieca Stereoscan. 440 model SEM) at an ... SEM image of rod-like nanocrystalline silver tungstate. Figure 3. ... Thermal analysis shows that the compound is thermally stable ...

  1. Carbon fiber structure for B.G.O. crystals of an electromagnetic calorimeter for energies around and above 2 GeV

    International Nuclear Information System (INIS)

    Anamateros, E.; Germenia, C.; Napoleone, T.

    1991-01-01

    This document describes a project to construct with composite material an Electromagnetic Calorimeter for a large, solid angle crystal ball for energies around and above 2 GeV, with thin walls (0.36 mm) and a complex figure like a 'Rugby Ball'. The contract was between the National Institute of Nuclear Physics (INFN) of Frascati, Genova, Catania, and Roma, and ITALCOMPOSITI - a joint venture between Agusta Group (50%) and ENI (50%) to research, produce and market advanced prepreg materials and composite structural components for aerospace, defense, energy, and transport applications. The contract concerns the design and the realization of the structure, which consists of 24 baskets containing 480 crystals of B.G.O. weighing about 4 Kg, each with full alveolus, including electronic systems

  2. Phase diagrams of KY(WO4)2-KEr(WO4)2, KGd(WO4)2-KEr(WO4)2 systems and single crystal growth for some tungstates

    International Nuclear Information System (INIS)

    Yudanova, L.I.; Pavlyuk, A.A.; Potapova, O.G.

    1992-01-01

    Phase diagrams of the KY(WO 4 ) 2 -KEr(WO 4 ) 2 , KGd(WO 4 ) 2 -KEr(WO 4 ) 2 systems were studied by differential thermal and X-ray diffraction analyses. Continuous variety of solid solutions are in the KY(WO 4 ) 2 -KEr(WO 4 ) 2 system. They occurred just as in the area of alphaso beta-modifications. Limited areas of the solid solutions based on components were in the KGd(WO 4 ) 2 -KEr(WO 4 ) 2 system. Monocrystals of potassium-yttrium and potassium-gadolinium tungstates activated by erbium were grown using modified low-gradient Czochralski method

  3. Hydrothermal syntheses and characterization of uranyl tungstates with electro-neutral structural units

    Energy Technology Data Exchange (ETDEWEB)

    Balboni, Enrica; Burns, Peter C. [Univ. of Notre Dame, IN (United States). Dept. of Civil and Enviromental Engineering and Earth Sciences; Univ. of Notre Dame, IN (United States). Dept. of Chemistry and Biochemistry

    2015-11-01

    Two uranyl tungstates, (UO{sub 2})(W{sub 2}O{sub 7})(H{sub 2}O){sub 3} (1) and (UO{sub 2}){sub 3}(W{sub 2}O{sub 8})F{sub 2}(H{sub 2}O){sub 3} (2), were synthesized under hydrothermal conditions at 220 C and were structurally, chemically, and spectroscopically characterized. 1 Crystallizes in space group Pbcm, a = 6.673(5) Aa, b = 12.601(11) Aa, c = 11.552 Aa; 2 is in C2/m, a = 13.648(1) Aa, b = 16.852(1) Aa, c = 9.832(1) Aa, β = 125.980(1) {sup circle}. In 1 the U(VI) cations are present as (UO{sub 2}){sup 2+} uranyl ions that are coordinated by five oxygen atoms to give pentagonal bipyramids. These share two edges with two tungstate octahedra and single vertices with four additional octahedra, resulting in a sheet with the iriginite-type anion topology. Only water molecules are located in the interlayer. The structural units of 2 consist of (UO{sub 2}){sup 2+} uranyl oxy-fluoride pentagonal bipyramids present as either [UO{sub 2}F{sub 2}O{sub 3}]{sup -6} or [UO{sub 2}FO{sub 4}]{sup -5}, and strongly distorted tungstate octahedra. The linkage of uranyl pentagonal bipyramids and tungstate octahedra gives a unique sheet anion topology consisting of pentagons, squares and triangles. In 2, the uranyl tungstates sheets are connected into a novel electro-neutral three-dimensional framework through dimers of uranyl pentagonal bipyramids. These dimers connecting the sheets share an edge defined by F anions. 2 is the first example of a uranyl tungstate oxy-fluoride, and 1 and 2 are rare examples of uranyl compounds containing electro-neutral structural units.

  4. Surface of crystallization of K, Rb//Cl, WO4 system

    International Nuclear Information System (INIS)

    Shurdumov, G.K.; Cherkesov, Z.A.; Shurdumov, B.K.

    2000-01-01

    Ternary mutual system of potassium and rubidium chlorides and tungstates is studied by visual-polythermal and differential thermal methods for the first time. It is established that liquidus of the system consists of crystallization fields of continuous double solid solutions on the base of components of binary potassium chloride - rubidium chloride and potassium tungstate - rubidium tungstate systems [ru

  5. Vanadate, molybdate and tungstate for orthomolecular medicine.

    Science.gov (United States)

    Matsumoto, J

    1994-09-01

    Recent studies indicate that oxyanions, such as vanadate (V) or vanadyl (IV), cause insulin-like effects on rats by stimulating the insulin receptor tyrosine kinase. Tungstate (VI) and molybdate (VI) show the same effects on rat adipocytes and hepatocytes. Results of uncontrolled trials on volunteers accumulated in Japan also suggest that tungstate effectively regulates diabetes mellitus without detectable side effects. Since these oxyanions naturally exist in organisms, oxyanion therapy, the oral administration of vanadate, vanadyl, molybdate, or tungstate, can be considered to be orthomolecular medicine. Therefore, these oxyanions may provide a viable alternative to chemotherapy. Many diseases in addition to diabetes mellitus might also be treated since the implication of these results is that tyrosine kinases are involved in a variety of diseases.

  6. Timing performance of the CMS electromagnetic calorimeter and prospects for the future

    CERN Document Server

    Bornheim, Adolf

    2014-01-01

    The CMS electromagnetic calorimeter (ECAL) is made of 75,848 scintillating lead tungstate crystals arranged in a barrel and two endcaps. The scintillation light is read out by avalanche photodiodes in the barrel and vacuum phototriodes in the endcaps, at which point the scintillation pulse is amplified and sampled at 40 MHz by the on-detector electronics. The fast signal from the crystal scintillation enables energy as well as timing measurements from the data collected in proton-proton collisions with high energy electrons and photons. The single-channel time resolution of ECAL measured at beam tests for high energy showers is better than 100 ps. The timing resolution achieved with the data collected in proton-proton collisions at the LHC is discussed. We present how precision timing is used in current physics measurements and discuss studies of subtle calorimetric effects, such as the timing response of different crystals belonging to the same electromagnetic shower. In addition, we present prospects for th...

  7. arXiv Strong reduction of the effective radiation length in an oriented PWO scintillator crystal

    CERN Document Server

    Bandiera, L.; Romagnoni, M.; Argiolas, N.; Bagli, E.; Ballerini, G.; Berra, A.; Brizzolani, C.; Camattari, R.; De Salvador, D.; Haurylavets, V.; Mascagna, V.; Mazzolari, A.; Prest, M.; Soldani, M.; Sytov, A.; Vallazza, E.

    We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of CERN SPS were critically compared to Monte Carlo simulations based on the Baier Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of five in case of beam alignment with the [001] crystal axes. The observed effect opens the way to the realization of compact electromagnetic calorimeters/detectors based on oriented scintillator crystals in which the amount of material can be strongly reduced with respect to the state of the art. These devices could have relevant applications in fixed-target experiments as well as in satellite-borne gamma-telescopes.

  8. CsI calorimeter of the CMD-3 detector

    International Nuclear Information System (INIS)

    Aulchenko, V.M.; Bondar, A.E.; Erofeev, A.L.; Kovalenko, O.A.; Kozyrev, A.N.; Kuzmin, A.S.; Logashenko, I.B.; Razuvaev, G.P.; Ruban, A.A.; Shebalin, V.E.; Shwartz, B.A.; Talyshev, A.A.; Titov, V.M.; Yudin, Yu.V.; Epifanov, D.A.

    2015-01-01

    The VEPP-2000 e + e − collider has been operated at Budker Institute of Nuclear Physics since 2010. The experiments are performed with two detectors CMD-3 and SND. The calorimetry at the CMD-3 detector is based on three subsystems, two coaxial barrel calorimeters—Liquid Xenon Calorimeter and crystal CsI calorimeter, and endcap calorimeter with BGO crystals. This paper describes the CsI calorimeter of the CMD-3 detector. The calorimeter design, its electronics and calibration procedures are discussed

  9. An FPGA-based slowcontrol module and a baseline shifting extension card for the sampling-ADC readout of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Urff, Georg; Poller, Timo [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    At the electron accelerator ELSA (Bonn) the CBELSA/TAPS experiment investigates the photoproduction of mesons off protons and neutrons. The CsI(Tl)-crystals of the Crystal Barrel calorimeter are being upgraded from a PIN-diode readout to an APD readout. In the context of this upgrade, an FPGA-based Sampling-ADC (SADC) is presently being developed (HK 304). A Slow-control Module for the SADC with TCP/Telnet access has been developed on the basis of a Spartan6 FPGA. Control and monitoring of the SADC's power supply as well as control of parameters of the analog and digital data processing in the SADC is realized via PMBus/I{sup 2}C. The prototype as well as an overview of its functionality will be presented. In order to fully utilize the dynamic input range of the SADCs, an interfacing extension board was designed. It receives the differential signal generated by previous amplification stages and adds an individual DC offset voltage to each channel supplied by a digital-to-analog converter. The circuit and the used techniques as well as simulations and measurements are presented.

  10. Study of the optical monitoring system of the scintillating crystal involved in the electromagnetic calorimeter of CMS experiment; Etude du systeme de suivi optique des cristaux scintillants du calorimetre electromagnetique de l`experience CMS

    Energy Technology Data Exchange (ETDEWEB)

    Geleoc, M

    1998-09-04

    The prospect of the experimental discovery of the Higgs boson is one of the motivations to build the large hadron collider (LHC). Proton beams will collide and the emitted particles will be detected by ATLAS and CMS equipment. In each detector the electromagnetic calorimeter will allow the characterisation of the 2 photons coming from one of the disintegration channels of the Higgs boson. CMS collaboration has chosen an homogeneous calorimeter fitted with PbWO{sub 4} crystals. Each crystal with its photodetector and its electronic device forms one detection channel. The resolution of the detection channels should not deteriorate all along the operating time. The optical monitoring system of the crystals logs then controls the response of each detection channel in order to allow an accurate calibration of the calorimeter. The optical properties, the resistance to irradiation of PbWO{sub 4} crystals and the modelling of light collection are investigated in this work. The description of the different components of the optical monitoring system highlights the technical difficulties we had to challenge. An experimental testing bench has been set up to study the coupling between the scintillation signal and the signal that feeds the monitoring system, this coupling has been studied under irradiation in the conditions of CMS operating. (A.C.) 94 refs.

  11. Optical lines in europium-terbium double activated calcium tungstate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Nazarov, M.V. [Department of Material Science and Engineering, Korea Advanced Institute of Science and Technology, 373-1 Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Tsukerblat, B.S. [Department of Chemistry, Ben-Gurion University of the Negev, 84105 Beer-Sheva (Israel)]. E-mail: tsuker@bgumail.bgu.ac.il; Popovici, E.-J. [' Raluca Ripan' Institute for Research in Chemistry, Cluj-Napoca (Romania); Jeon, D.Y. [Department of Material Science and Engineering, Korea Advanced Institute of Science and Technology, 373-1 Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2004-09-20

    The Letter is devoted to the problem of the optical anisotropy of the rare-earth ions occupying low-symmetry positions in crystals. The crystal field multiplets arising from LSJ terms of Eu{sup 3+} and Tb{sup 3+} ions in the crystal field of calcium tungstate scheelite (CaWO{sub 4}) are analyzed with regard to the experimental data on the low temperature photoluminescence and cathodoluminescence spectra. The selection rules as well as an angular (polarization) dependence of the two-photon absorption are discussed.

  12. Design studies for the Phase II upgrade of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Orimoto, Toyoko Jennifer

    2016-01-01

    The High Luminosity LHC (HL-LHC) will provide unprecedented instantaneous and integrated luminosity. The lead tungstate crystals forming the barrel part of the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) will still perform well, even after the expected integrated luminosity of 3000fb-1 at the end of HL-LHC. The avalanche photodiodes (APDs) used to detect the scintillation light will also continue to be operational, although there will be some increase in noise due to radiation-induced dark currents. This will be mitigated by reducing the barrel operating temperature during HL-LHC running.The front-end electronics of the ECAL barrel will be replaced, in order to remove existing constraints on trigger rate and latency and to provide additional capability to fully exploit the higher luminosity delivered by the HL-LHC. New developments in high-speed optical links will allow single-crystal readout at 40 MHz to upgraded off-detector processors, allowing maximum flexibility and enhanced tri...

  13. Low-temperature flux growth of sulfates, molybdates, and tungstates of Ca, Sr, and Ba and investigation of doping with Mn6+

    NARCIS (Netherlands)

    Romanyuk, Y.E.; Ehrentraut, D.; Pollnau, Markus; Garcia-Revilla, S.; Valiente, R.

    The growth of undoped and $Mn^{6+}$-doped molybdates and tungstates of alkali-earth metals and BaSO4 has been investigated. Single crystals were grown by the flux method within the temperature range of 600–475 °C, using the ternary NaCl–KCl–CsCl solvent. Sizes of undoped crystals increase within the

  14. Seven up. The incorporation of Li{sup +} cations in yttrium tungstate and silicate tungstate

    Energy Technology Data Exchange (ETDEWEB)

    Dorn, Katharina V.; Schustereit, Tanja; Strobel, Sabine; Hartenbach, Ingo [Institute for Inorganic Chemistry, University of Stuttgart (Germany)

    2017-12-13

    Lithium yttrium(III) oxidotungstate(VI), LiY{sub 5}W{sub 8}O{sub 32}, was synthesized by solid-state reaction of a mixture of lithium chloride, yttrium sesquioxide, and tungsten trioxide. It crystallizes monoclinically in space group C2/c (a = 1908.34(5) pm, b = 561.80(1) pm, c = 1147.22(3) pm, β = 111.255(2) , Z = 2). The structure comprises one mixed Li{sup +}/Y{sup 3+} cationic position (molar ratio Li:Y1 = 1:1) and one cationic position exclusively occupied by Y{sup 3+} cations. All W{sup 6+} cations are surrounded by six O{sup 2-} anions, forming distorted octahedral coordination polyhedra, which are mutually linked by both edges and vertices to cascaded {sup 2}{sub ∞}{[W_4O_1_6]"8"-} layers. Lithium yttrium(III) oxidosilicate(IV) oxidotungstate(VI), LiY{sub 5}[SiO{sub 4}]{sub 2}[WO{sub 4}]{sub 4}, was obtained as by-product in the synthesis of YF[WO{sub 4}] by sintering a mixture of Y{sub 2}O{sub 3}, YF{sub 3}, and WO{sub 3} with lithium chloride as fluxing agent in sealed silica ampoules. It crystallizes orthorhombically in space group Pban (a = 512.08(4) pm, b = 1673.35(12) pm, c = 493.68(4) pm, Z = 1) bearing one mixed crystallographic position occupied by Li{sup +} and Y{sup 3+} cations in a molar ratio of 1:3 and one exclusive Y{sup 3+} position in its structure. The coordination polyhedra around the Si{sup 4+} and W{sup 6+} cations are isolated tetrahedra built up by four O{sup 2-} anions each. The crystal structure of this silicate tungstate can be derived from the scheelite-type structure by inserting anionic {sup 2}{sub ∞}{(Y2[SiO_4])"-} layers between cationic {sup 2}{sub ∞}{[(Li/Y1)_2[WO_4]_2]"+} double layers. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Inorganic scintillators for detector systems physical principles and crystal engineering

    CERN Document Server

    Lecoq, Paul; Korzhik, Mikhail

    2017-01-01

    This second edition features new chapters highlighting advances in our understanding of the behavior and properties of scintillators, and the discovery of new families of materials with light yield and excellent energy resolution very close to the theoretical limit. The book focuses on the discovery of next-generation scintillation materials and on a deeper understanding of fundamental processes. Such novel materials with high light yield as well as significant advances in crystal engineering offer exciting new perspectives. Most promising is the application of scintillators for precise time tagging of events, at the level of 100 ps or higher, heralding a new era in medical applications and particle physics. Since the discovery of the Higgs Boson with a clear signature in the lead tungstate scintillating blocks of the CMS Electromagnetic Calorimeter detector, the current trend in particle physics is toward very high luminosity colliders, in which timing performance will ultimately be essential to mitigating...

  16. The Prism Plastic Calorimeter (PPC)

    CERN Multimedia

    2002-01-01

    This proposal supports two goals: \\\\ \\\\ First goal:~~Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter~(PPC) towers with a new ``liquid crystal'' type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. \\\\ \\\\ Second goal:~~Describe how one can design a warm liquid calorimeter integrated into a LHC detector and to list the advantages of the PPC: low price, minimum of mechanical structures, minimum of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronic being outside of the liquid and easily accessible, one has maximum flexibility to define them. \\\\ \\\\ The R&D program, we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  17. A HPMT based set-up to characterize scintillating crystals

    International Nuclear Information System (INIS)

    D'Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R.

    1999-01-01

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  18. A HPMT based set-up to characterize scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    D' Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R

    1999-09-21

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  19. Synthesis, structure characterization and catalytic activity of nickel tungstate nanoparticles

    Science.gov (United States)

    Pourmortazavi, Seied Mahdi; Rahimi-Nasrabadi, Mehdi; Khalilian-Shalamzari, Morteza; Zahedi, Mir Mahdi; Hajimirsadeghi, Seiedeh Somayyeh; Omrani, Ismail

    2012-12-01

    Taguchi robust design was applied to optimize experimental parameters for controllable, simple and fast synthesis of nickel tungstate nanoparticles. NiWO4 nanoparticles were synthesized by precipitation reaction involving addition of nickel ion solution to the tungstate aqueous reagent and then formation of nickel tungstate nucleolus which are insoluble in aqueous media. Effects of various parameters such as nickel and tungstate concentrations, flow rate of reagent addition and reactor temperature on diameter of synthesized nickel tungstate nanoparticles were investigated experimentally by the aid of orthogonal array design. The results for analysis of variance (ANOVA) showed that particle size of nickel tungstate can be effectively tuned by controlling significant variables involving nickel and tungstate concentrations and flow rate; while, temperature of the reactor has a no considerable effect on the size of NiWO4 particles. The ANOVA results proposed the optimum conditions for synthesis of nickel tungstate nanoparticles via this technique. Also, under optimum condition nanoparticles of NiWO4 were prepared and their structure and chemical composition were characterized by means of EDAX, XRD, SEM, FT-IR spectroscopy, UV-vis spectroscopy, and photoluminescence. Finally, catalytic activity of the nanoparticles in a cycloaddition reaction was examined.

  20. Products of tungstate ion interaction with primary aliphatic amines

    International Nuclear Information System (INIS)

    Skrylev, L.D.; Sejfullina, I.I.; Purich, A.N.; Babinets, S.K.

    1982-01-01

    Using the methods of conductometric titration, IR-spectroscopic and thermographic analyses precipitates formed in the process of interaction of diluted aqueous solutions of sodium tungstate with alcoholic solutions of dodecyl-, tetradecyl- and octadecylamine have been studied. It is shown that as a result of interaction tungstates of corresponding amines are formed. The structure and thermal stability of singled out products are determined

  1. Plutonium assay calorimeters

    International Nuclear Information System (INIS)

    Perry, R.B.

    1978-01-01

    Three calorimeters were developed for the IAEA: a small-sample portable calorimeter, a bulk calorimeter for up to 2 kg Pu in cans and capable of measuring up to 25 watts, and a calorimeter for 4-m long LWR Pu-recycle fuel roads. Design parameters and performance capability are given, and the instruments are compared with those developed for NRC

  2. Energy calibration of the barrel calorimeter of the CMD-3 detector

    International Nuclear Information System (INIS)

    Anisenkov, A.V.; Aulchenko, V.M.; Bashtovoy, N.S.; Bondar, A.E.; Grebenuk, A.A.; Epifanov, D.A.; Epshteyn, L.B.; Erofeev, A.L.; Kovalenko, O.A.; Kozyrev, A.N.; Kuzmin, A.S.; Mikhailov, K.Yu.; Logashenko, I.B.; Razuvaev, G.P.; Ruban, A.A.; Shebalin, V.E.; Shwartz, B.A.; Talyshev, A.A.; Titov, V.M.; Yudin, Yu.V.

    2017-01-01

    The VEPP-2000 e + e − collider has been operated in the Budker Institute of Nuclear Physics since 2010. Experiments are carried out with two detectors CMD-3 and SND. The calorimetry at the CMD-3 detector is based on three subsystems, two coaxial barrel calorimeters—Liquid Xenon calorimeter and crystal CsI calorimeter, and end cap calorimeter with BGO crystals. This paper describes the procedures of the energy calibration of the combined barrel calorimeter of the CMD-3 detector.

  3. SiPM based readout system for PbWO4 crystals

    Science.gov (United States)

    Berra, A.; Bolognini, D.; Bonfanti, S.; Bonvicini, V.; Lietti, D.; Penzo, A.; Prest, M.; Stoppani, L.; Vallazza, E.

    2013-08-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20-100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs.

  4. SiPM based readout system for PbWO4 crystals

    International Nuclear Information System (INIS)

    Berra, A.; Bolognini, D.; Bonfanti, S.; Bonvicini, V.; Lietti, D.; Penzo, A.; Prest, M.; Stoppani, L.; Vallazza, E.

    2013-01-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20–100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs

  5. SiPM based readout system for PbWO{sub 4} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Berra, A., E-mail: alessandro.berra@gmail.com [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Bolognini, D.; Bonfanti, S. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Lietti, D. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Penzo, A. [INFN sezione di Trieste (Italy); Prest, M.; Stoppani, L. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2013-08-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20–100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs.

  6. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL crystal calorimeter (EB + EE) The Barrel and Endcaps ECAL calorimeters have been used routinely in global runs. The CRAFT data have confirmed that ECAL performance is the same with or without magnetic field. The CRUZET and CRAFT runs have allowed experience to be gained with ECAL operation in many areas, in particular for the trigger and the calibration sequence using gap events (laser events and LED pulsing). More details can be found in the Commissioning/DPG report in this bulletin.   The last components remaining to be installed and commissioned are the specific Endcap Trigger modules (TCC-48). Most of the modules have been delivered to LLR and half of them are already at CERN. In parallel, large progress has been made on the validation of the TCC-48 firmware. Preshower (ES) The Preshower project has also made impressive progress during Autumn. All the elements required to complete the detector assembly are at hand. Ladder assembly, test and calibration with cosmic rays at the operating ...

  7. TupA: A Tungstate Binding Protein in the Periplasm of Desulfovibrio alaskensis G20

    Directory of Open Access Journals (Sweden)

    Ana Rita Otrelo-Cardoso

    2014-07-01

    Full Text Available The TupABC system is involved in the cellular uptake of tungsten and belongs to the ABC (ATP binding cassette-type transporter systems. The TupA component is a periplasmic protein that binds tungstate anions, which are then transported through the membrane by the TupB component using ATP hydrolysis as the energy source (the reaction catalyzed by the ModC component. We report the heterologous expression, purification, determination of affinity binding constants and crystallization of the Desulfovibrio alaskensis G20 TupA. The tupA gene (locus tag Dde_0234 was cloned in the pET46 Enterokinase/Ligation-Independent Cloning (LIC expression vector, and the construct was used to transform BL21 (DE3 cells. TupA expression and purification were optimized to a final yield of 10 mg of soluble pure protein per liter of culture medium. Native polyacrylamide gel electrophoresis was carried out showing that TupA binds both tungstate and molybdate ions and has no significant interaction with sulfate, phosphate or perchlorate. Quantitative analysis of metal binding by isothermal titration calorimetry was in agreement with these results, but in addition, shows that TupA has higher affinity to tungstate than molybdate. The protein crystallizes in the presence of 30% (w/v polyethylene glycol 3350 using the hanging-drop vapor diffusion method. The crystals diffract X-rays beyond 1.4 Å resolution and belong to the P21 space group, with cell parameters a = 52.25 Å, b = 42.50 Å, c = 54.71 Å, β = 95.43°. A molecular replacement solution was found, and the structure is currently under refinement.

  8. Regularities of the chlorination process of phosphates and tungstates of some actinide and fission elements in chloride melts

    International Nuclear Information System (INIS)

    Kryukova, A.I.; Chernikov, A.A.; Skiba, O.V.; Kazantsev, G.N.

    1988-01-01

    Results of kinetic studies of chlorination process of crystal phosphates and tungstates of uranium, cerium, zirconium, plutonium by vapours of carbon tetrachloride in the melts of alkali element chlorides at of 973-1073 K have been analyzed. Mathematical models for the process description are suggested. Analysis of adequate models of regression type permitted to solve the problem of statistical evaluation of affecting factors and to predict within factor space studied the conditions for the optimal process course

  9. Synthesis and characterization of ceramic powders of pure and doped with trivalent erbium barium tungstate

    International Nuclear Information System (INIS)

    Sousa, R.B. de; Nascimento, V.A. do; Matos, J. M.E. de; Santos, M.R.M.C.

    2014-01-01

    This research proposes the synthesis and characterization of pure and doped with Er"3"+ (1 and 2 %) barium tungstate powders prepared by the coprecipitation method. In order to characterize the obtained powders were used X-Ray Diffractometry, Raman Spectroscopy and Fourier Transform Infrared Spectroscopy. According to the standard XRD spectra, the crystals exhibited the presence of tetragonal scheelite structure without the presence of secondary phases. Raman spectra showed the presence of eleven vibrational modes and two modes were observed in the infrared spectra. The synthesized oxides showed good crystallinity and structurally ordered at short and long-range. (author)

  10. Installing the ATLAS calorimeter

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    The eight toroid magnets can be seen surrounding the calorimeter that is later moved into the middle of the detector. This calorimeter will measure the energies of particles produced when protons collide in the centre of the detector.

  11. OPAL detector electromagnetic calorimeter

    CERN Multimedia

    1988-01-01

    Half of the electromagnetic calorimeter of the OPAL detector is seen in this photo. This calorimeter consists of 4720 blocks of lead glass. It was used to detect and measure the energy of photons, electrons and positrons by absorbing them.

  12. Peltier ac calorimeter

    OpenAIRE

    Jung, D. H.; Moon, I. K.; Jeong, Y. H.

    2001-01-01

    A new ac calorimeter, utilizing the Peltier effect of a thermocouple junction as an ac power source, is described. This Peltier ac calorimeter allows to measure the absolute value of heat capacity of small solid samples with sub-milligrams of mass. The calorimeter can also be used as a dynamic one with a dynamic range of several decades at low frequencies.

  13. Quartz fiber calorimeter

    International Nuclear Information System (INIS)

    Akchurin, N.; Doulas, S.; Ganel, O.; Gershtein, Y.; Gavrilov, V.; Kolosov, V.; Kuleshov, S.; Litvinsev, D.; Merlo, J.-P.; Onel, Y.; Osborne, D.; Rosowsky, A.; Stolin, V.; Sulak, L.; Sullivan, J.; Ulyanov, A.; Wigmans, R.; Winn, D.

    1996-01-01

    A calorimeter with optical quartz fibers embedded into an absorber matrix was proposed for the small angle region of the CMS detector at LHC (CERN). This type of calorimeter is expected to be radiation hard and to produce extremely fast signal. Some results from beam tests of the quartz fiber calorimeter prototype are presented. (orig.)

  14. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL Barrel (EB) The cabling of the ECAL Barrel services on YB0 was completed early December 2007. The team has now commissioned the complete Barrel. To run all the supermodules in parallel, it is necessary to remove the heat from the service cables on YB0. The corresponding thermal screens are being installed and, for the time being, a max¬imum of 25 supermodules has been run concurrently. EB is read out regularly with a local DAQ as well as with the central DAQ and trigger. The calorimeter trigger has also been commissioned, allowing us to trigger on cosmic muons. ECAL Endcaps (EE) The Endcaps crystal production will be completed before the end of March 2008, as planned. The gluing of the VPTs (Vacuum Photo Triodes) on the crystals and the assembly of Supercrystals (sets of 25 crystals) are proceeding at the pace of 16 Supercrystals (400 channels) per week. Two thirds of the Supercrystals needed for the complete EE have been produced. Their mounting on the Dee backplates (including the connectio...

  15. Impact of Non-Uniformity in Light Collection on the Energy Resolution of the PANDA Electromagnetic Calorimeter at Photon Energies Below 1 GeV

    Science.gov (United States)

    Diehl, Stefan; Brinkmann, Kai-Thomas; Drexler, Peter; Dormenev, Valery; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA-Collaboration

    2017-11-01

    The electromagnetic calorimeter (EMC) of the PANDA detector at the future FAIR facility comprises more than 15,000 lead tungstate (PWO) crystals. The barrel part will consist of 11 crystal geometries with different degree of tapering, which causes a non-uniformity in light collection as an interplay between the focusing and the internal absorption of the light. For the most tapered crystals the detected light is enhanced by 40%, if the scintillation process is created in the front part of the crystal. Due to the shower development and its fluctuations the non-uniformity leads to a reduction of the energy resolution. To reduce this effect, one lateral crystal side face has been de-polished to a roughness of 0.3 μm. Measurements confirm an increase of the light yield in the rear part of the crystal. In contrast, only a slight decrease can be observed in the front part. The overall non-uniformity is significantly reduced below 5%. This paper will discuss the experimental studies based on GEANT4 and optical simulations to understand the impact of a de-polished side face on the light collection. For consequences on the future performance, a 3×3 sub-array of de-polished crystals was directly studied using a tagged photon beam in the energy range from 50 MeV up to 800 MeV, respectively, performed at the tagged photon facility at MAMI, Mainz. The comparison to an array composed of polished crystals confirms a significant improvement of the constant term of the energy resolution from above 2 % down to 0.5 % and only a small increase of the statistical term. The results can be reproduced in GEANT4 simulations.

  16. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Science.gov (United States)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg; PANDA Collaboration

    2017-06-01

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  17. Measurement and optimization of the light collection uniformity in strongly tapered PWO crystals of the PANDA detector

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Stefan; Bremer, Daniel; Brinkmann, Kai-Thomas; Dormenev, Valery; Eissner, Tobias; Novotny, Rainer W.; Rosenbaum, Christoph; Zaunick, Hans-Georg

    2017-06-11

    The uniformity of the light collection is a crucial parameter for detectors based on inorganic scintillation crystals to guarantee a response proportional to the deposited energy. Especially in case of tapered crystals, like they are widely used to realize a 4π geometry of electromagnetic calorimeters (EMC) in high energy physics experiments, a strong non-uniformity is introduced by an additional focusing of the scintillation light due to the tapered geometry. The paper will discuss the determination and the reduction of the non-uniformity in strongly tapered lead tungstate crystals as used for the construction of the electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research (FAIR). Among different concepts for an uniformization a single de-polished lateral side face provided the optimum result with a remaining non-uniformity below 5% in good agreement with similar studies for the CMS ECAL at LHC. The impact on the achievable energy resolution in the energy regime of photons below 800 MeV is discussed in detail in comparison to GEANT4 simulations. The comparison of the response of two arrays with polished and de-polished crystals, respectively, shows in the latter case a significant improvement of the constant term of the parametrization of the energy resolution down to 0.5% accompanied by only very slight increase of the statistical term.

  18. Synthesis, structure characterization and catalytic activity of nickel tungstate nanoparticles

    International Nuclear Information System (INIS)

    Pourmortazavi, Seied Mahdi; Rahimi-Nasrabadi, Mehdi; Khalilian-Shalamzari, Morteza; Zahedi, Mir Mahdi; Hajimirsadeghi, Seiedeh Somayyeh; Omrani, Ismail

    2012-01-01

    Graphical abstract: NiWO 4 nanoparticles were prepared via precipitation technique. Experimental parameters of procedure were optimized statistically. Highlights: ► NiWO 4 spherical nanoparticles were synthesized via direct precipitation method. ► Taguchi robust design was used for optimization of synthesis reaction parameters. ► Composition and structural properties of NiWO 4 nanoparticles were characterized. ► EDAX, XRD, SEM, FT-IR, UV–vis and photoluminescence techniques were employed. ► Catalytic activity of the product in a cyclo-addition reaction was investigated. - Abstract: Taguchi robust design was applied to optimize experimental parameters for controllable, simple and fast synthesis of nickel tungstate nanoparticles. NiWO 4 nanoparticles were synthesized by precipitation reaction involving addition of nickel ion solution to the tungstate aqueous reagent and then formation of nickel tungstate nucleolus which are insoluble in aqueous media. Effects of various parameters such as nickel and tungstate concentrations, flow rate of reagent addition and reactor temperature on diameter of synthesized nickel tungstate nanoparticles were investigated experimentally by the aid of orthogonal array design. The results for analysis of variance (ANOVA) showed that particle size of nickel tungstate can be effectively tuned by controlling significant variables involving nickel and tungstate concentrations and flow rate; while, temperature of the reactor has a no considerable effect on the size of NiWO 4 particles. The ANOVA results proposed the optimum conditions for synthesis of nickel tungstate nanoparticles via this technique. Also, under optimum condition nanoparticles of NiWO 4 were prepared and their structure and chemical composition were characterized by means of EDAX, XRD, SEM, FT-IR spectroscopy, UV–vis spectroscopy, and photoluminescence. Finally, catalytic activity of the nanoparticles in a cycloaddition reaction was examined.

  19. Synthesis, structure characterization and catalytic activity of nickel tungstate nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Pourmortazavi, Seied Mahdi, E-mail: pourmortazavi@yahoo.com [Faculty of Material and Manufacturing Technologies, Malek Ashtar University of Technology, Tehran (Iran, Islamic Republic of); Rahimi-Nasrabadi, Mehdi, E-mail: rahiminasrabadi@gmail.com [Department of Chemistry, Imam Hossein University, Tehran (Iran, Islamic Republic of); Khalilian-Shalamzari, Morteza [Department of Chemistry, Imam Hossein University, Tehran (Iran, Islamic Republic of); Zahedi, Mir Mahdi; Hajimirsadeghi, Seiedeh Somayyeh [Islamic Azad University, Varamin Pishva Branch, Varamin (Iran, Islamic Republic of); Omrani, Ismail [Department of Chemistry, Imam Hossein University, Tehran (Iran, Islamic Republic of)

    2012-12-15

    Graphical abstract: NiWO{sub 4} nanoparticles were prepared via precipitation technique. Experimental parameters of procedure were optimized statistically. Highlights: Black-Right-Pointing-Pointer NiWO{sub 4} spherical nanoparticles were synthesized via direct precipitation method. Black-Right-Pointing-Pointer Taguchi robust design was used for optimization of synthesis reaction parameters. Black-Right-Pointing-Pointer Composition and structural properties of NiWO{sub 4} nanoparticles were characterized. Black-Right-Pointing-Pointer EDAX, XRD, SEM, FT-IR, UV-vis and photoluminescence techniques were employed. Black-Right-Pointing-Pointer Catalytic activity of the product in a cyclo-addition reaction was investigated. - Abstract: Taguchi robust design was applied to optimize experimental parameters for controllable, simple and fast synthesis of nickel tungstate nanoparticles. NiWO{sub 4} nanoparticles were synthesized by precipitation reaction involving addition of nickel ion solution to the tungstate aqueous reagent and then formation of nickel tungstate nucleolus which are insoluble in aqueous media. Effects of various parameters such as nickel and tungstate concentrations, flow rate of reagent addition and reactor temperature on diameter of synthesized nickel tungstate nanoparticles were investigated experimentally by the aid of orthogonal array design. The results for analysis of variance (ANOVA) showed that particle size of nickel tungstate can be effectively tuned by controlling significant variables involving nickel and tungstate concentrations and flow rate; while, temperature of the reactor has a no considerable effect on the size of NiWO{sub 4} particles. The ANOVA results proposed the optimum conditions for synthesis of nickel tungstate nanoparticles via this technique. Also, under optimum condition nanoparticles of NiWO{sub 4} were prepared and their structure and chemical composition were characterized by means of EDAX, XRD, SEM, FT-IR spectroscopy, UV

  20. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  1. Study of characteristics of gamma-irradiated materials for calorimeters

    International Nuclear Information System (INIS)

    Britvich, G.I.; Vasil'chenko, V.G.; Peresypkin, A.I.

    1992-01-01

    The radiation resistance of some structural materials proposed for use in electromagnetic calorimeters is studied. Particular attention is given to the spectral, dose, and other postradiation characteristics of pure heavy fluorides and their solid solutions: The promise of the use of CdF 2 and CdI 2 crystals in calorimeters is noted. 19 refs., 5 figs

  2. Study and optimization of the performances of the CMS electromagnetic calorimeter for the physics at LHC; Etude et optimisation des performances du calorimetre electromagnetique de l'experience CMS pour la physique au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, J

    2007-07-15

    The CMS experiment (Compact Muon Solenoid) is one of the two multi-purpose experiments of the proton-proton collider LHC (Large Hadron Collider). One of the main goals of CMS is the search for the Higgs boson. The collaboration has chosen an electromagnetic calorimeter made of about 75000 scintillating lead tungstate crystals PbWO{sub 4}, at the same time fast, radiation hard, and extremely precise, especially in the energy range for the Higgs boson search, in the channel where it decays in 2 photons. The five first chapters of this thesis present the LHC, the CMS detector and notably the electromagnetic calorimeter (ECAL). The sixth chapter presents a test beam analysis realized in 2004 at CERN with an electron beam of different energies (20-250 GeV) incident on a part (1/36) of the calorimeter barrel called super-module. A study of the energy measurement variation within 9 (3*3) and 25 (5*5) crystals matrices as function of the impact position of the initial electron was done to infer a correction method of the energy measured as function of different parameters. This method has improved very significantly the energy resolution of the calorimeter in the test beam configuration. The last chapter of this thesis presents an application of this correction method for the electrons and photons in the full simulation chain of CMS. The energy reconstruction of photons and electrons is more complicated compared to the test beam case, because of an important amount of matter in front of the calorimeter and of the strong magnetic field in the central part of the CMS detector. The photons have a non negligible probability to convert into an electron-positron pair before the calorimeter, while the electrons (and positrons), whose trajectory is bent in the transverse plan, lose energy in the matter and can emit a random number of Bremsstrahlung photons. A reconstruction algorithm of the electrons and photons energy has been developed to take into account this issue and to

  3. Characterization of PbWO4 crystals for high-energy physics experiments

    Science.gov (United States)

    Kim, M. J.; Park, H.; Kim, H. J.

    2016-09-01

    High-energy physics (HEP) experiments have employed many new types of scintillators. Specifically, bismuth germanate, thallium-doped cesium iodide, and lead tungstate (PbWO4, PWO) have been used for the L3 experiment; CLEO II, Belle and BES-III; and CMS, respectively. PWO has particularly beneficial properties, such as high density, fast decay time, short radiation length and radiation hardness. In this study, we tested the PWO crystals at low temperatures to determine their applicability in future calorimeters. Various crystals from the Proton Antiproton Annihilations at Darmstadt (PANDA) experiment in Giessen, the Bogoroditsk Techno-Chemical Plant (BTCP) in Russia and by Shanghai Institute of Ceramics, Chinese Academy of Sciences (SICCAS) in China were investigated. We studied the scintillation properties of PWO crystals, such as their X-ray luminescence, relative light yields, absolute light yields, energy resolutions, decay times and longitudinal uniformities of their light yields. In addition, we measured the temperature dependences of the light yields and decay times by using a 137Cs γ-ray source. The emission spectra of the PWO crystals consisted of a broad band from 350 nm to 700 nm, and the peak emission wavelength in each spectrum was 420 nm. The emission spectra of the PWO crystals from SICCAS were slightly shifted to longer wavelengths compared with those of the crystals from the other institutions.

  4. The BaBar electromagnetic calorimeter

    CERN Document Server

    Lewandowski, B

    2002-01-01

    The BaBar electromagnetic calorimeter is a hermetic, total-absorption array of CsI(Tl)-crystals, operated at the asymmetric e sup - e sup + -collider PEP-II at SLAC. The design and the status of the performance as of February 2002 is presented.

  5. Micro Calorimeter for Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Santhanagopalan, Shriram [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-01

    As battery technology forges ahead and consumer demand for safer, more affordable, high-performance batteries grows, the National Renewable Energy Laboratory (NREL) has added a patented Micro Calorimeter to its existing family of R&D 100 Award-winning Isothermal Battery Calorimeters (IBCs). The Micro Calorimeter examines the thermal signature of battery chemistries early on in the design cycle using popular coin cell and small pouch cell designs, which are simple to fabricate and study.

  6. LHCb calorimeter electronics. Photon identification. Calorimeter calibration

    International Nuclear Information System (INIS)

    Machefert, F.

    2011-01-01

    LHCb is one of the four large experiments installed on the LHC accelerator ring. The aim of the detector is to precisely measure CP violation observables and rare decays in the B meson sector. The calorimeter system of LHCb is made of four sub-systems: the scintillating pad detector, the pre-shower, the electromagnetic (ECAL) and hadronic (HCAL) calorimeters. It is essential to reconstruct B decays, to efficiently trigger on interesting events and to identify electrons and photons. After a review of the LHCb detector sub-systems, the first part of this document describes the calorimeter electronics. First, the front-end electronics in charge of measuring the ECAL and HCAL signals from the photomultipliers is presented, then the following section is an overview of the control card of the four calorimeters. The chapters three and four concern the test software of this electronics and the technological choices making it tolerant to radiations in the LHCb cavern environment. The measurements performed to ensure this tolerance are also given. The second part of this document concerns both the identification of the photons with LHCb and the calibration of the calorimeters. The photon identification method is presented and the performances given. Finally, the absolute energy calibration of the PRS and ECAL, based on the data stored in 2010 is explained. (author)

  7. Synchrotron-based far-infrared spectroscopy of nickel tungstate

    International Nuclear Information System (INIS)

    Kalinko, A.; Kuzmin, A.; Roy, P.; Evarestov, R.A.

    2016-01-01

    Monoclinic antiferromagnetic NiWO 4 was studied by far-infrared (30-600 cm -1 ) absorption spectroscopy in the temperature range of 5-300 K using the synchrotron radiation from SOLEIL source. Two isomorphous CoWO 4 and ZnWO 4 tungstates were investigated for comparison. The phonon contributions in the far-infrared range of tungstates were interpreted using the first-principles spin-polarized linear combination of atomic orbital calculations. No contributions from magnetic excitations were found in NiWO 4 and CoWO 4 below their Neel temperatures down to 5 K.

  8. On surface reactions of iron tungstate with ethane

    International Nuclear Information System (INIS)

    Obrubov, V.A.; Shchukin, V.P.; Averbukh, A.Ya.

    1980-01-01

    Results of investigation of ethane oxidation reaction upon iron tungstate are presented. It is shown that catalytic oxidation of ethane is accompanied by the surface reaction of the catalyst reduction. Maximum reduction of surface depends upon temperature and considerably affects the direction of ethane oxidation process. Activation energies of ethane oxidation reactions and surface reaction of iron tungstate reduction depend on the surface actual state and at its reduction up to 5% from monolayer change in the limits 36.0-46.0 and 53.0-66.0 kcal/mol respectively

  9. AIDA: concerted calorimeter development

    CERN Multimedia

    Felix Sefkow

    2013-01-01

    AIDA – the EU-funded project bringing together more than 80 institutes worldwide – aims at developing new detector solutions for future accelerators. Among the highlights reported at AIDA’s recent annual meeting in Frascati was the completion of an impressive calorimeter test beam programme, conducted by the CALICE collaboration over the past two years at CERN’s PS and SPS beam lines.   The CALICE tungsten calorimeter prototype under test at CERN. This cubic-metre hadron calorimeter prototype has almost 500,000 individually read-out electronics channels – more than all the calorimeters of ATLAS and CMS put together. Calorimeter development in AIDA is mainly motivated by experiments at possible future electron-positron colliders, namely ILC or CLIC. The physics requirements of such future machines demand extremely high-performance calorimetry. This is best achieved using a finely segmented system that reconstructs events using the so-called pa...

  10. Contribution to the study of electromagnetic calorimeter with PbWO{sub 4} crystals in the CMS experiment at LHC; Contribution a l`etude du calorimetre electromagnetique a cristaux de PbWO{sub 4} de l`experience CMS au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Benhammou, Y [Lyon-1 Univ., 69 (France)

    1997-01-13

    The Higgs bosons can be observed in the [90-130] GeV mass range in the channel h -> {gamma}{gamma} if a high resolution electromagnetic calorimeter is used. The needed performances are met in the Pb W O{sub 4} crystals. This thesis is devoted to the study of the first Pb W O{sub 4} crystals (23 cm length) and their associated electronic equipment. Of crucial importance it was found to be the behaviour of these crystals under long radiation exposure. The understanding of the radiation effects, the crystal growth procedure mastering and the realization of a green light monitoring system of high performance were successful results obtained in the study described in this thesis. A rather high energy (0.6 % at 100 GeV) and position resolution was achieved by using a APD readout. In addition, the prototype of a final readout chain of large dynamic range and low consumption was built with very encouraging results. Concerning the APDs it was established that increasing the active surface and reduction of exceeding noise factor F improves significantly the stochastic term in the energy resolution. Besides, a complete readout chain comprising current preamplifiers, a linear compressing (multi-slope) system and a fast ADC (40 MHz), were found necessary to met the requirements imposed on the high performing Pb W O{sub 4} calorimeter. Research and development works based on the pioneering studies described in this thesis devoted to the crystal calorimeters are underway 77 refs.

  11. International workshop on calorimeter simulation

    International Nuclear Information System (INIS)

    Filges, D.; Cloth, P.

    1988-10-01

    The aim of the Juelich workshop was to provide an overview of the state of calorimeter simulation and the methods used. This resulted in 29 contributions to the following topics: Code systems relevant to calorimeter simulation, vectorization and code speed-up, simulation of calorimeter experiments, special applications of calorimeter simulation. This report presents the viewgraphs of the given talks. (orig./HSI)

  12. Intercalibration of the CMS Electromagnetic Calorimeter Using Jet Trigger Events

    CERN Document Server

    Futyan, David

    2004-01-01

    This note describes a strategy for rapidly obtaining electromagnetic calorimeter crystal intercalibration at LHC start-up in the absence of test beam precalibration of the complete detector. In the case of the CMS (Compact Muon Solenoid) Electromagnetic Calorimeter, the limit on the precision to which crystals can be intercalibrated in phi using fully simulated jet trigger events, and assuming complete ignorance of the distribution of material in front of the calorimeter, is determined as a function of the pseudorapidity eta. The value of the limit has been found to be close to 1.5% in the barrel and between 3.0% and 1.0% for the fiducial region of the endcaps. The precision is limited by the inhomogeneity of tracker material. With increasing knowledge of the material distribution in the tracker, the attainable precision of the method will increase, with the potential of providing rapid and repeated calibration of the calorimeter.

  13. Reduction of tungstates and molybdates by hydrogen and thermodynamic properties of these salts

    International Nuclear Information System (INIS)

    Gerasimov, Ya.I.; Rezukhina, T.N.; Simanov, Yu.P.; Vasil'eva, I.A.; Kurshakova, R.D.

    1988-01-01

    Study of thermodynamic properties of a series of tungstates of bivalent metals (Mg, Ca, Sr, Ba, Mn, Co, Fe, Ni, Cu, Zn, Cd and Pb) as well as of some molybdates- of Mg, Ca, Sr, Ba is carried out. The obtained values are compared with magnetic characteristics of compounds and parameters of their crystal lattices. Thermodynamic properties were studied by measuring constants of their reduction with hydrogen in the 500-1350 deg C temperature range. It is concluded that dependence of thermodynamic values on geometric parameters of the lattice is not definitive. Comparison of salt formation atomic entropies with deviations of salt magnetic moments from theoretical ionic moments points to the fact of existence of some accordance between these two series of values. 25 refs.; 10 figs.; 6 tabs

  14. Calorimeters for biotechnology

    International Nuclear Information System (INIS)

    Russell, Donald J.; Hansen, Lee D.

    2006-01-01

    The isothermal and temperature scanning calorimeters manufactured by Calorimetry Sciences Corporation are briefly described. Applications of calorimetry to determine thermodynamics and kinetics of reactions of interest in biotechnology are described with illustrative examples

  15. GSPEL - Calorimeter Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Testing performance claims on heat transfer componentsThe Calorimeter Lab, located in the Ground Systems Power and Energy Lab (GSPEL), is one of the largest in the...

  16. New heavy scintillating materials for precise heterogeneous EM-calorimeters

    International Nuclear Information System (INIS)

    Britvich, G.I.; Britvich, I.G.; Vasil'chenko, V.G.; Lishin, V.A.; Obraztsov, V.F.; Polyakov, V.A.; Solovjev, A.S.; Ryzhikov, V.D.

    2001-01-01

    This investigation shows some optical and scintillation properties of new scintillating media, based on heavy composite materials and an inorganic crystal CsI:Br, intended for the creation of precise heterogeneous EM-calorimeters with the energy resolution σ/E congruent with 4-5% E-radical. The possibility to use cheap heavy scintillating plates based on optical ceramics as active media in heterogeneous EM-calorimeters is considered

  17. The ATLAS electromagnetic calorimeter

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Michel Mathieu, a technician for the ATLAS collaboration, is cabling the ATLAS electromagnetic calorimeter's first end-cap, before insertion into its cryostat. Millions of wires are connected to the electromagnetic calorimeter on this end-cap that must be carefully fed out from the detector so that data can be read out. Every element on the detector will be attached to one of these wires so that a full digital map of the end-cap can be recreated.

  18. Proportional wire calorimeters at ISABELLE

    International Nuclear Information System (INIS)

    Matthews, J.A.J.

    1979-01-01

    Gas calorimeters have recently increased in popularity because they provide a simple method of achieving a high degree of calorimeter segmentation with only a modest loss in energy resolution compared with liquid argon or scintillator calorimeters. High radiation levels at ISABELLE will result in gas calorimeter lifetimes similar to those of MWPCs, although the intermediate speed of these devices may cause some resolution degradation due to signal pileup. Schemes for calibration and monitoring gas calorimeters in situ must be evolved and will presumably utilize a combination of pulsers, imbedded 55 Fe sources, etc. Most of the recent development work on gas calorimeters has been centered on electromagnetic (em) calorimetry for large detectors at CESR and PEP. Data on the performance of gas calorimeters are given and compared with the liquid argon results of Hitlin et al. The hadronic gas calorimeter results of Anderson et al. are shown along with typical energy resolution results from various scintillator and liquid argon steel calorimeters

  19. Geometric alignment of the CMD-3 endcap electromagnetic calorimeter using events of two-quantum annihilation

    International Nuclear Information System (INIS)

    Akhmetshin, R.R.; Grigoriev, D.N.; Kazanin, V.F.; Kuzmenko, A.E.; Timofeev, A.V.

    2017-01-01

    Since 2010 the electromagnetic endcap calorimeter based on BGO crystals is used in experiments as one of the systems of the CMD-3 detector. The spacial resolution is one of crucial parameters of the calorimeter. Inaccurate knowledge of the real calorimeter position can limit the resolution. In this work the alignment of the center of the calorimeter with respect to the tracking system of the CMD-3 detector has been performed using events of two-quantum annihilation. The alignment technique that has been used to determine the position of the calorimeter is described. Finally, the improvement in spacial resolution of the calorimeter after applying the correction for the real calorimeter position is shown.

  20. Transport kinetics of hydrogen permeable lanthanum tungstate

    Energy Technology Data Exchange (ETDEWEB)

    Falkenstein, Andreas

    2017-01-24

    The electrical conductivity relaxation technique is a widely used method to determine the oxygen transport parameters of mixed ionic-electronic conductors. In recent years, it has been modified to investigate the hydration behavior of proton conducting mixed conductors, giving access to up to four transport parameters in a single relaxation experiment, the diffusion coefficients and surface reaction rates of hydrogen and oxygen. In this work, the transport properties of the fluorite type protonic conductor lanthanum tungstate have been investigated by means of electrical conductivity relaxation. The experiments were performed in a temperature range from 650 C to 950 C, in a pO{sub 2} range from 3 mbar to 100 mbar and in a pH{sub 2}O range from 10 mbar to 100 mbar and in dry atmosphere. At high temperatures, the conductivity relaxation curve follows the expected two-fold non-monotonic behavior upon hydration. At low temperatures, however, the contribution of the fast hydrogen kinetic decreases and by a further decrease of the temperature, the relaxation shows two-fold monotonic behavior. The power factors - the contribution of each single fold relaxation curve to the resulting two-fold relaxation curve, which is a superposition - have been derived to explain the behavior mentioned above. The activation energy of the oxygen incorporation is rather low. Hence, oxidation experiments were performed in dry atmospheres in order to investigate if the origin of the oxygen species is relevant. The results revealed higher activation energies, which was expected, but also higher absolute values of the surface reaction rate and the diffusion coefficient. Oxidation experiments with increasing humidity revealed that the increased diffusivity cannot be attributed to the total concentrations of electron holes and proton interstitials. First experiments using spectroscopic relaxation, which is dependent on the concentration of hydroxy-anions only, were performed. Absorption bands

  1. Magnetically Coupled Calorimeters

    Science.gov (United States)

    Bandler, Simon

    2011-01-01

    Calorimeters that utilize the temperature sensitivity of magnetism have been under development for over 20 years. They have targeted a variety of different applications that require very high resolution spectroscopy. I will describe the properties of this sensor technology that distinguish it from other low temperature detectors and emphasize the types of application to which they appear best suited. I will review what has been learned so far about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. I will introduce some of the applications where magnetic calorimeters are being used and also where they are in development for future experiments. So far, most magnetic calorimeter research has concentrated on the use of paramagnets to provide temperature sensitivity; recent studies have also focused on magnetically coupled calorimeters that utilize the diamagnetic response of superconductors. I will present some of the highlights of this research, and contrast the properties of the two magnetically coupled calorimeter types.

  2. The ATLAS Tile Calorimeter

    CERN Document Server

    Henriques Correia, Ana Maria

    2015-01-01

    TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics.

  3. The ATLAS Tile Calorimeter

    International Nuclear Information System (INIS)

    Henriques, A.

    2015-01-01

    TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics. (authors)

  4. ALICE Zero Degree Calorimeter

    CERN Multimedia

    De Marco, N

    2013-01-01

    Two identical sets of calorimeters are located on both sides with respect to the beam Interaction Point (IP), 112.5 m away from it. Each set of detectors consists of a neutron (ZN) and a proton (ZP) Zero Degree Calorimeter (ZDC), positioned on remotely controlled platforms. The ZN is placed at zero degree with respect to the LHC beam axis, between the two beam pipes, while the ZP is positioned externally to the outgoing beam pipe. The spectator protons are separated from the ion beams by means of the dipole magnet D1.

  5. SLD liquid argon calorimeter

    International Nuclear Information System (INIS)

    Vella, E.

    1992-10-01

    The liquid argon calorimeter (LAC) of the SLD detector is a parallel plate -- liquid argon sampling calorimeter, used to measure particle energies in Z 0 decays at the Stanford Linear Collider. The LAC module design is based on a unique projective tower structure, in which lead plates and segmented lead tiles serve both as absorbers and electrodes. The LAC front end electronics incorporates several novel features, including extensive multiplexing and optical fiber readout, which take advantage of the low SLC beam crossing frequency. The operational performance of the LAC during the recently completed SLD physics run (which recorded over 10,000 Z 0 events) is discussed

  6. Modeling of Reaction Calorimeter

    OpenAIRE

    Farzad, Reza

    2014-01-01

    The purpose of this project was to model the reaction calorimeter in order to calculate the heat of absorption which is the most important parameter in this work. Reaction calorimeter is an apparatus which is used in measuring the heat of absorption of CO2 as well as the total pressure in vapor phase based on vapor-liquid equilibrium state. Mixture of monoethanolamine (MEA) and water was used as a solvent to absorb the CO2.Project was divided in to three parts in order to make the programming...

  7. A digital calorimeter

    International Nuclear Information System (INIS)

    Nitschke, J.M.

    1983-01-01

    The paper describes a calorimeter which is used to determine the particle flux of an accelerator. It incorporates as its principal feature a Peltier module which is operated in a constant current pulse mode. Via a feedback arrangement, the Peltier module thermally compensates the heat generated by the particle beam by supplying discrete 'cooling quanta'. The number of 'quanta' generated per unit time is measured with a frequency counter and is proportional to the beam power. The calorimeter can be calibrated via internal resistors which dissipate a precisely known amount of power in the target. (orig.)

  8. The SDC central calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Proudfoot, J.

    1992-01-01

    An overview of the calorimeter being designed and constructed by Solenoidal Detector Collaboration (SDC) for use at the Superconducting SuperCollider is presented. The collaboration have chosen to build a sampling calorimeter using scintillating tile with wavelength-shifter fiber readout as the detector medium, and absorber media of lead and iron for the electromagnetic and hadronic compartments. This choice was based on a substantial amount of R D and Monte Carlo simulation calculations, which showed that it both met the necessary experimental specifications in addition to being a cost effect design.

  9. The SDC central calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Proudfoot, J.; The SDC Collaboration

    1992-11-01

    An overview of the calorimeter being designed and constructed by Solenoidal Detector Collaboration (SDC) for use at the Superconducting SuperCollider is presented. The collaboration have chosen to build a sampling calorimeter using scintillating tile with wavelength-shifter fiber readout as the detector medium, and absorber media of lead and iron for the electromagnetic and hadronic compartments. This choice was based on a substantial amount of R&D and Monte Carlo simulation calculations, which showed that it both met the necessary experimental specifications in addition to being a cost effect design.

  10. Luminescence investigation of R{sup 3+}-doped alkaline earth tungstates prepared by a soft chemistry method

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Helliomar P. [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil); Kai, Jiang [Pontifícia Universidade Católica do Rio de Janeiro, Departamento de Química, Rio de Janeiro, RJ, Brazil (Brazil); Silva, Ivan G.N.; Rodrigues, Lucas C.V. [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil); Felinto, Maria C.F.C. [Centro de Química e Meio Ambiente, Instituto de Pesquisas Energéticas e Nucleares, São Paulo, SP (Brazil); Hölsä, Jorma [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil); Department of Chemistry, University of Turku,FI-20014 Turku (Finland); Turku University Centre for Materials and Surfaces (MatSurf), Turku (Finland); Malta, Oscar L. [Departamento de Química Fundamental, Universidade Federal de Pernambuco, Recife, PE (Brazil); Brito, Hermi F., E-mail: hefbrito@iq.usp.br [Instituto de Química, Universidade de São Paulo, São Paulo, SP (Brazil)

    2016-02-15

    Highly luminescent rare earth (R{sup 3+}) doped alkaline-earth tungstates MWO{sub 4}:R{sup 3+} (M{sup 2+}: Ca, Sr and Ba, R{sup 3+}: Eu, Tb, Gd) were prepared with a room temperature coprecipitation method. The phosphors were characterized by X-ray powder diffraction (XPD), thermal analysis (TG), infrared absorption spectroscopy (FTIR) and UV excited photoluminescence. The as-prepared MWO{sub 4}:R{sup 3+} particles belong to the tetragonal scheelite phase, and are well crystallized and are of the average size of 16–48 nm. The excitation and emission spectra of the materials were recorded at 300 and 77 K temperatures. The luminescent materials exhibit intense red (Eu{sup 3+}) and green (Tb{sup 3+}) colors under UV excitation. The excitation spectra of the Eu{sup 3+} doped materials show broad bands arising from the ligand-to-metal charge transfer transitions (O{sup 2−}→W{sup VI} and O{sup 2−}→Eu{sup 3+}) as well as narrow bands from 4f–4f intraconfigurational transitions of Eu{sup 3+}. 4f–4f emission data of the Eu{sup 3+} and Tb{sup 3+} in the MWO{sub 4} host matrices as well as the values of emission quantum efficiencies of the {sup 5}D{sub 0} level and the 4f–4f experimental intensity parameters of Eu{sup 3+} ion are presented and discussed. - Highlights: • Highly red Europium and green Terbium doped tungstate under UV excitation. • Efficient energy transfer process from tungstate to R{sup 3+} ion. • Promising candidates for a red (Eu{sup 3+}) and green (Tb{sup 3+}) emitting phosphors. • Ligand Metal charge transfer to R{sup 3+} ion. • Charge compensation with Na{sup +}.

  11. MAC calorimeters and applications

    International Nuclear Information System (INIS)

    MAC Collaboration.

    1982-03-01

    The MAC detector at PEP features a large solid-angle electromagnetic/hadronic calorimeter system, augmented by magnetic charged-particle tracking, muon analysis and scintillator triggering. Its implementation in the context of electron-positron annihilation physics is described, with emphasis on the utilization of calorimetry

  12. CMS Central Hadron Calorimeter

    OpenAIRE

    Budd, Howard S.

    2001-01-01

    We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam.

  13. Gas calorimeter workshop: proceedings

    International Nuclear Information System (INIS)

    1982-01-01

    Gas calorimeters combining functions of energy measurement and fine tracking have become more and more popular in the past few years. They help identify muons, gammas, electrons, and hadrons within dense tracks from transverse and longitudinal shower development. Fine segmentation capability using pads and strips on the cathodes have made gas-sampling calorimeters very attractive for colliding-beam detectors where a large multiplicity of particles are detected in a projected geometry. Linearity, energy resolution, shower position resolution, multishower resolution, and calibration questions were discussed in detail at the workshop. Ease of energy calibration by monitoring radioactive sources, good gain uniformity, and gain stability obtained were among the topics of the speakers. There was a discussion session on the operation mode of wire chambers. Gas calorimeters have been used successfully at CERN, Cornell, Fermilab, and SLAC for experiments. Some of the results from those large-scale devices were reported. Future usage of gas-sampling calorimeters for colliding-beam experiments at Fermilab and CERN were discussed. Wire chambers using extruded conductive plastic tubes have made construction easy of pads and strips which can conveniently read out induced signals from the cathode. The results of extensive studies on such devices were discussed. Separate entries were prepared for the data base for the 17 papers presented

  14. An Inexpensive Solution Calorimeter

    Science.gov (United States)

    Kavanagh, Emma; Mindel, Sam; Robertson, Giles; Hughes, D. E. Peter

    2008-01-01

    We describe the construction of a simple solution calorimeter, using a miniature bead thermistor as a temperature-sensing element. This has a response time of a few seconds and made it possible to carry out a thermometric reaction in under a minute, which led to minimal heat losses. Small temperature changes of 1 K associated with enthalpies of…

  15. Calorimeter for thermal sources

    International Nuclear Information System (INIS)

    Shai, I.; Shaham, Ch.; Barnea, I.

    1978-12-01

    A calorimeter was built, enabling the thermal power of radioactive sources to be measured in the range of 50 to 120 mW. The system was calibrated with an electrical heater. The calibration curves serve to determine the power of radioactive sources with a reasonable accuracy

  16. Automatic low-temperature calorimeter

    International Nuclear Information System (INIS)

    Malyshev, V.M.; Mil'ner, G.A.; Shibakin, V.F.; Sorkin, E.L.

    1986-01-01

    This paper describes a low-temperature adiabatic calorimeter with a range of 1.5-500K. The system for maintaining adiabatic conditions is implemented by two resitance thermometers, whose sensitivity at low temperatures is several orders higher than that of thermocouples. The calorimeter cryostat is installed in an STG-40 portable Dewar flask. The calorimeter is controlled by an Elektronika-60 microcomputer. Standard platinum and germanium thermometers were placed inside of the calorimeter to calibrate the thermometers of the calorimeter and the shield, and the specific heats of specimens of OSCh 11-4 copper and KTP-8 paste were measured to demonstrate the possibilities of the described calorimeter. Experience with the calorimeter has shown that a thorough study of the dependence of heat capacity on temperature (over 100 points for one specimen) can be performed in one or two dats

  17. The Status of GLAST CsI Calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Chekhtman, A.

    2003-09-18

    GLAST is a gamma-ray observatory for celestial sources in the energy range from 20 MeV to 300 GeV. This is NASA project with launch anticipated in 2006. The principal instrument of the GLAST mission is the Large Area Telescope (LAT), consisting of an Anti Coincidence Detector (ACD), a silicon-strip detector Tracker (TKR) and a hodoscopic CsI Calorimeter (CAL). It consists of 16 identical modules arranged in a 4 x 4 array. Each module has horizontal dimensions 38 x 38 cm{sup 2} and active thickness 8.5 radiation length. It contains 96 CsI (Tl) crystals arranged in 8 layers with 12 crystals per layer. The scintillation light is measured by PIN photodiodes mounted on both ends of each crystal. The sum of signals at the two ends of the crystal provides the energy measurement. The difference in these signals provides the position measurement along the crystal. The calorimeter was designed to meet the goals of good energy resolution (better than 10% for photon energies 100 MeV-100 GeV), position resolution of {approx} 1 mm for photon energies > 1 GeV, and a rejection factor of > 100 for charged cosmic rays, under limitations on calorimeter weight (95 kg per module) and power consumption (6 W per module). The Monte Carlo simulation and prototype beam test results confirm that proposed design meets the requirements. Calorimeter production is planned to start in 2003.

  18. On tungstates of divalent cations (II). Polymorphy of Pb{sub 2}WO{sub 5}

    Energy Technology Data Exchange (ETDEWEB)

    Jantz, Stephan G.; Dialer, Marwin; Hoeppe, Henning A. [Lehrstuhl fuer Festkoerperchemie, Universitaet Augsburg (Germany); Pielnhofer, Florian [Abteilung Nanochemie, Max-Planck-Institut fuer Festkoerperforschung, Stuttgart (Germany)

    2017-12-13

    The phase transition from the low temperature form Pb{sub 2}[WO{sub 5}] to its high temperature form Pb{sub 2}O[WO{sub 4}] was monitored by means of temperature dependent powder XRD. Single-crystals of Pb{sub 2}[WO{sub 5}], suitable for a structure determination by single-crystal X-ray diffraction, were obtained by quenching a sample from 500 C to room temperature. The low-temperature phase Pb{sub 2}[WO{sub 5}] comprises the structural motive of infinite zigzag chains built by cornersharing WO{sub 6} octahedra, known from the tungstates M{sub 2}[WO{sub 5}] (M = Sr, Ba), but crystallizes in a new structure type [C2/c, a = 14.0996(4) Aa, b = 5.8579(2) Aa, c = 12.6877(4) Aa, β = 114.3569(13) , Z = 8, R{sub int} = 0.042, R{sub 1} = 0.040, wR{sub 2} = 0.068]. The crystal structure of the high-temperature phase Pb{sub 2}O[WO{sub 4}] [C2/m, a = 14.2126(4) Aa, b = 5.80150(10) Aa, c = 7.3477(2) Aa, β = 113.9402(7) , Z = 4, R{sub 1} = 0.035, wR{sub 2} = 0.055] is revised, based on single-crystal XRD data. Furthermore spectroscopic data (IR, Raman and UV/Vis spectra) are presented. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Some peculiarities of zirconium tungstate synthesis by thermal decomposition of hydrothermal precursors

    International Nuclear Information System (INIS)

    Gubanov, Alexander I.; Dedova, Elena S.; Plyusnin, Pavel E.; Filatov, Eugeny Y.; Kardash, Tatyana Y.; Korenev, Sergey V.; Kulkov, Sergey N.

    2014-01-01

    Highlights: • Synthesis of ZrW 2 O 8 using hydrothermal method. • On hydrothermal synthesis optimal conc. of HCl in the reaction mixture is 2.3 M. • Thermal decomposition of ZrW 2 O 7 ((OH) 1.5 ,Cl 0.5 )·2H 2 O begins are 200 °S. • Amorphous intermediate crystallizes into cubic single-phase ZrW 2 O 8 above 550 °S. • ZrW 2 O 8 destructed at temperatures above 700 °S. - Abstract: This article discusses some peculiarities of the synthesis of ZrW 2 O 8 (1) using thermal decomposition of the precursor ZrW 2 O 7 ((OH) 1.5 ,Cl 0.5 )·2H 2 O (2) prepared by hydrothermal method. On hydrothermal synthesis of 2 the optimal concentration of hydrochloric acid in the reaction mixture is about 2.3 M. TG approach to determine the chemical composition of the precursor was suggested. It has been found that the precursor for the synthesis of zirconium tungstate has chemical formula 2. Thermal decomposition of the precursor 2 begins at 200 °S and affords an amorphous intermediate, which crystallizes as a cubic phase 1 above 550 °S with an exoeffect. The temperature of the beginning of the transition from amorphous to the crystalline state is 350 ± 25 °S

  20. Photodiode read-out of the ALICE photon spectrometer $PbWO_{4}$ crystals

    CERN Document Server

    Man'ko, V I; Sibiryak, Yu; Volkov, M; Klovning, A; Maeland, O A; Odland, O H; Rongved, R; Skaali, B

    1999-01-01

    Proposal of abstract for LEB99, Snowmass, Colorado, 20-24 September 1999The PHOton Spectrometer of the ALICE experiment is an electromagnetic calorimeter of high granularity consisting of 17280 lead-tungstate (PWO) crystals of dimensions 22x22x180 mm3, read out by large-area PIN-diodes with very low-noise front-end electronics. The crystal assembly is operated at -25C to increase the PWO light yield. A 16.1x17.1 mm2 photodiode, optimized for the PWO emissio spectrum at 400-500 nm, has been developed. The 20x20 mm2 preamplifier PCB is attached to the back side of the diode ceramic frame. The charge sensitive preamplifier is built in discrete logic with two input JFETs for optimum matching with the ~150pF PIN-diode. A prototype shaper has been designed and built in discrete logic. For a detector matrix of 64 units the measured ENCs are between 450-550e at -25C. Beam tests demonstrate that the required energy resolution is reached.Summary:The PHOton Spectrometer of the ALICE experiment is an electromagnetic calo...

  1. Thin films prepared from tungstate glass matrix

    Energy Technology Data Exchange (ETDEWEB)

    Montanari, B.; Ribeiro, S.J.L.; Messaddeq, Y. [Departamento de Quimica Geral e Inorganica, Instituto de Quimica, Sao Paulo State University-UNESP, CP 355, CEP 14800-900, Araraquara, SP (Brazil); Li, M.S. [Instituto de Fisica, USP, CP 369, CEP 13560-970, Sao Carlos, SP (Brazil); Poirier, G. [Departamento de Ciencias Exatas, UNIFAL-MG, CEP 37130-000, Alfenas-MG (Brazil)], E-mail: gael@unifal-mg.edu.br

    2008-01-30

    Vitreous samples containing high concentrations of WO{sub 3} (above 40% M) have been used as a target to prepare thin films. Such films were deposited using the electron beam evaporation method onto soda-lime glass substrates. These films were characterized by X-ray diffraction (XRD), perfilometry, X-ray energy dispersion spectroscopy (EDS), M-Lines and UV-vis absorption spectroscopy. In this work, experimental parameters were established to obtain stable thin films showing a chemical composition close to the glass precursor composition and with a high concentration of WO{sub 3}. These amorphous thin films of about 4 {mu}m in thickness exhibit a deep blue coloration but they can be bleached by thermal treatment near the glass transition temperature. Such bleached films show several guided modes in the visible region and have a high refractive index. Controlled crystallization was realized and thus it was possible to obtain WO{sub 3} microcrystals in the amorphous phase.

  2. Tritium diffusion in polycrystalline lithium tungstate

    International Nuclear Information System (INIS)

    Krutyakov, A.N.; Shadrin, A.A.; Saunin, E.I.; Gromov, V.V.; Shafiev, A.I.

    1984-01-01

    Using radiometric method the investigation of tritium separation from neutron irradiated (neutron flux density 1.2x10 13 n/cm 2 xs) polycrystalline Li 2 WO 4 in the temperature range 200-680 deg C has been carried out. It is established that the use of helium as gas-carrier of flow-type gas-discharge counter permits to conduct continuous stable measurements of concentrations of tritium extracted depending on its chemical state. It is shown that volume diffusion is the process, limiting tritiated particle separation rate from Li 2 WO 4 . It is found that the process of tritium volume diffusion in Li 2 WO 4 corresponds to two different mechanisms respectively in low- (200-300 deg C) and high-temperature (350-680 deg C) ranges. A supposition is made that in the low-temperature range the process of diffusion is conditioned by the dissociation of the radiation defect-tritiated particle complex, which is confirmed by the data on radiation defect annealing in Li 2 WO 4 . The value of activation energy of tritium separation process in the range 350-680 deg C, proved to be equal to 13.3 kJ/mol. Possible role of crystal structure peculiarities of Li 2 WO 4 for diffusion process is pointed out

  3. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    Roger Rusack

    Occupancy of the trigger primitives during a global run: the observed pattern is consistent with the polar angle dependence of the transverse energy equivalent of the electronic noise in the endcaps.   Progress on ECAL since the last CMS week has been mostly on three major fronts: we have continued with the installation and commissioning of the preshower detectors; the endcap calorimeter trigger has been installed and tested; and there have been many changes to the calorimeter detector control and safety systems. Both Preshower (ES) endcaps were installed in CMS on schedule, just before Easter. There followed a campaign of "first commissioning" to ensure that all services were correctly connected (electrical, optical, cooling, etc.). Apart from some optical ribbons that had to be replaced the process went rather smoothly, finishing on 23rd April. All power supplies are installed and operational. The cooling system (two branches of the joint Tracker-Preshower system) is fully fun...

  4. NA48 prototype calorimeter

    CERN Multimedia

    1990-01-01

    This is a calorimeter, a detector which measures the energy of particles. When in use, it is filled with liquid krypton at -152°C. Electrons and photons passing through interact with the krypton, creating a shower of charged particles which are collected on the copper ribbons. The ribbons are aligned to an accuracy of a tenth of a millimetre. The folding at each end allows them to be kept absolutely flat. Each shower of particles also creates a signal in scintillating material embedded in the support disks. These flashes of light are transmitted to electronics by the optical fibres along the side of the detector. They give the time at which the interaction occurred. The photo shows the calorimeter at NA48, a CERN experiment which is trying to understand the lack of anti-matter in the Universe today.

  5. UA2 central calorimeter

    CERN Multimedia

    The UA2 central calorimeter measured the energy of individual particles created in proton-antiproton collisions. Accurate calibration allowed the W and Z masses to be measured with a precision of about 1%. The calorimeter had 24 slices like this one, each weighing 4 tons. The slices were arranged like orange segments around the collision point. Incoming particles produced showers of secondary particles in the layers of heavy material. These showers passed through the layers of plastic scintillator, generating light which was taken by light guides (green) to the data collection electronics. The amount of light was proportional to the energy of the original particle. The inner 23 cm of lead and plastic sandwiches measured electrons and photons; the outer 80 cm of iron and plastic sandwiches measured strongly interacting hadrons. The detector was calibrated by injecting light through optical fibres or by placing a radioactive source in the tube on the bottom edge.

  6. Harwell Graphite Calorimeter

    International Nuclear Information System (INIS)

    Linacre, J.K.

    1970-01-01

    The calorimeter is of the steady state temperature difference type. It contains a graphite sample supported axially in a graphite outer jacket, the assembly being contained in a thin stainless steel outer can. The temperature of the jacket and the temperature difference between sample and jacket are measured by chromel-alumel thermocouples. The instrument is calibrated by means of an electric heater of low mass positioned on the axis of the sample. The resistance of the heater is known and both current through the heater and the potential across it may be measured. The instrument is filled with nitrogen at a pressure of one half atmosphere at room temperature. The calorimeter has been designed for prolonged operation at temperatures up to 600°C, and dose rates up to 1 Wg -1 , and instruments have been in use for periods in excess of one year

  7. The CMS Outer Hadron Calorimeter

    CERN Document Server

    Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Bawa, Harinder Singh; Beri, Suman Bala; Bhandari, Virender; Bhatnagar, Vipin; Chendvankar, Sanjay; Deshpande, Pandurang Vishnu; Dugad, Shashikant; Ganguli, Som N; Guchait, Monoranjan; Gurtu, Atul; Kalmani, Suresh Devendrappa; Kaur, Manjit; Kohli, Jatinder Mohan; Krishnaswamy, Marthi Ramaswamy; Kumar, Arun; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Narasimham, Vemuri Syamala; Patil, Mandakini Ravindra; Reddy, L V; Satyanarayana, B; Sharma, Seema; Singh, B; Singh, Jas Bir; Sudhakar, Katta; Tonwar, Suresh C; Verma, Piyush

    2006-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with a outer calorimeter to ensure high energy shower containment in CMS and thus working as a tail catcher. Fabrication, testing and calibrations of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter has a very good signal to background ratio even for a minimum ionising particle and can hence be used in coincidence with the Resistive Plate Chambers of the CMS detector for the muon trigger.

  8. Precision titration mini-calorimeter

    International Nuclear Information System (INIS)

    Ensor, D.; Kullberg, L.; Choppin, G.

    1977-01-01

    The design and test of a small volume calorimeter of high precision and simple design is described. The calorimeter operates with solution sample volumes in the range of 3 to 5 ml. The results of experiments on the entropy changes for two standard reactions: (1) reaction of tris(hydroxymethyl)aminomethane with hydrochloric acid and (2) reaction between mercury(II) and bromide ions are reported to confirm the accuracy and overall performance of the calorimeter

  9. Double tungstates of metals of scandium and ammonium subgroups

    Energy Technology Data Exchange (ETDEWEB)

    Maksin, V I [AN Ukrainskoj SSR, Kiev. Inst. Kolloidnoj Khimii i Khimii Vody

    1980-06-01

    The methods of pH-potentiometry, conductometry, determination of residual concentrations of liquid phases and precipitations, selected by chemical analysis have been used for investigation R(NO/sub 3/)/sub 3/-(NH/sub 4/)/sub 2/WO/sub 2/-H/sub 2/O systems, (where R=Sc, Y, La). The formation of double tungstates NH/sub 4/R(WO/sub 4/)/sub 2/xnH/sub 2/O is established. The NH/sub 4/Sc(WO/sub 4/)/sub 2/x4.5H/sub 2/O, NH/sub 4/Yx(WO/sub 4/)/sub 2/x3H/sub 2/O, NH/sub 4/La(WO/sub 4/)/sub 2/x1.5H/sub 2/O compounds are synthesized in individual form. Precipitation conditions (pH, concentration ratio) and composition of the solid phase are determined. The behaviour of synthesized slats at thermolysis up to 880 deg C is studied. Physicochemical properties (color, solubility of the simple and double tungstates of scandium, yttrium and lanthanum with ammonium) is studied. IR spectra and X-ray diffraction analysis give idea about double salts structural transformations.

  10. Tungstate adsorption onto Italian soils with different characteristics.

    Science.gov (United States)

    Petruzzelli, Gianniantonio; Pedron, Francesca

    2017-08-01

    The study of tungsten in the environment is currently of considerable interest because of the growing concerns resulting from its possible toxicity and carcinogenicity. Adsorption reactions are some of the fundamental processes governing the fate and transport of tungsten compounds in soil. This paper reports data on the adsorption of tungstate ions in three different Italian soils, which are characteristic of the Mediterranean region. The results show that pH is the most important factor governing the adsorption of tungstate in these soils. The data interpreted according to the Langmuir equation show that the maximum value of adsorption is approximately 30 mmol kg -1 for the most acidic soil (pH = 4.50) and approximately 9 mmol kg -1 for the most basic soil (pH = 7.40). In addition, soil organic matter is shown to play a fundamental role in adsorption processes, which are favored in soils with a higher organic matter content. The data could contribute to a better understanding of the behavior of tungsten compounds in Italian soils for which current knowledge is very scarce, also in view of environmental regulations, which are currently lacking.

  11. Interaction of cadmium and indium nitrate mixture with sodium tungstate in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Belousova, E E; Krivobok, V I; Gruba, A I [Donetskij Gosudarstvennyj Univ. (Ukrainian SSR)

    1982-01-01

    The interaction of the mixture of cadmium and indium nitrates with sodium tungstate in aqueous solution is studied using the methods of ''residual concentrations'', pH potentiometry and conductometry. Independent of the ratio of components in the initial solution a mixture of coprecipitated normal tungstates of cadmium and indium is formed in the system. Heat treatment of the precipitates at 800 deg C for 50 hrs with subsequent hardening results in the formation of solid solutions on the basis of normal cadmium and indium tungstates.

  12. Elevated gamma-rays shielding property in lead-free bismuth tungstate by nanofabricating structures

    Science.gov (United States)

    Liu, Jun-Hua; Zhang, Quan-Ping; Sun, Nan; Zhao, Yang; Shi, Rui; Zhou, Yuan-Lin; Zheng, Jian

    2018-01-01

    Radiation shielding materials have attracted much attention across academia and industry because of the increasing of nuclear activities. To achieve the materials with low toxicity but good protective capability is one of the most significant goals for personal protective articles. Here, bismuth tungstate nanostructures are controllably fabricated by a versatile hydrothermal treatment under various temperatures. The crystals structure and morphology of products are detailedly characterized with X-ray diffraction, electron microscope and specific surface area. It is noteworthy that desired Bi2WO6 nanosheets treated with 190 °C show the higher specific surface area (19.5 m2g-1) than that of the other two products. Importantly, it has a close attenuating property to lead based counterpart for low energy gamma-rays. Due to the less toxicity, Bi2WO6 nanosheets are more suitable than lead based materials to fabricate personal protective articles for shielding low energy radiations and have great application prospect as well as market potential.

  13. An investigation on the preparation of nanocrystalline hydrous zirconia from zirconium tungstate

    Science.gov (United States)

    Antunes, M.; Perottoni, C. A.; Gouvêa, D.; Machado, G.; Zorzi, J. E.

    2018-02-01

    Hydrous nanocrystalline zirconia was prepared from an unusual precursor—the bimetallic oxide zirconium tungstate (ZrW2O8)—in alkaline medium. Different experimental conditions (NaOH concentration, time and temperature) were used to investigate the effects on crystallographic, morphological, chemical and thermal characteristics of the products. The resulting materials are composed of particles with a crystal structure similar to that of cubic ZrO2 (or a mixture of tetragonal and cubic phases, depending on the synthesis conditions), with particle size around 5 nm and crystallites around 3 nm in diameter. These particles form high surface area agglomerates, exhibiting mesoporosity and capacity for adsorption of water and carbon dioxide. The synthesis mechanism appears to be constituted, first, by a chemical substitution reaction between the WO4 tetrahedra and hydroxyl ions, with subsequent solubilization of the structure. Indeed, excess hydroxyls in the medium form colloidal zirconium ions which polymerize/condense, generating crystalline nuclei in a process facilitated by heterogeneous nucleation and supersaturation. The presence of residual tungsten in all samples appears to be a key element for stabilizing the size and crystalline structure of the materials produced.

  14. R&D proposal the prism plastic calorimeter:PPC

    CERN Document Server

    Dobrzynski, Ludwik; Marchand, P; Nédélec, P; Salin, P; CERN. Geneva. Detector Research and Development Committee

    1990-01-01

    This proposal supports two goals: First Goal_Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter (PPC) towers with a new "liquid crystal" type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. Second Goal_ Describe how one can design a warm liquid calorimeter integrated into a LHC detector,and list the advantages of the PPC: low price, minimum of mechanical structures, minimum amount of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronics being outside the liquid and easily accessible, one has maximum flexibility to define them. The R&D program we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  15. Response of the GLAST LAT calorimeter to relativistic heavy ions

    International Nuclear Information System (INIS)

    Lott, B.; Piron, F.; Blank, B.; Bogaert, G.; Bregeon, J.; Canchel, G.; Chekhtman, A.; D'Avezac, P.; Dumora, D.; Giovinazzo, J.; Grove, J.E.; Hellstroem, M.; Jacholkowska, A.; Johnson, W.N.; Nuss, E.; Reposeur, Th.; Smith, D.A.; Suemmerer, K.

    2006-01-01

    The CsI calorimeter of the Gamma-Ray Large-Area Space Telescope (GLAST) will be calibrated in flight with cosmic-ray heavy ions. In order to determine the response of the calorimeter to relativistic heavy ions lighter than Fe, an experiment was carried out at the GSI heavy ion facility using the Fragment Separator (FRS). The measured response exhibits an unexpected feature for light ions, opposite to that observed at low incident energy: for a given deposited energy, the observed signal is greater for these ions than for protons (or more generally Z=1 minimum ionizing particles). Pulse shapes are found to be almost identical for carbon ions and Z=1 particles, with a significant slow scintillation component, which constitutes another departure from the low-energy behavior. Data on the energy resolution for the individual CsI crystals and on the loss of ions due to nuclear reactions in the calorimeter are also presented

  16. ELECTROMAGNET CALORIMETER (ECAL)

    CERN Multimedia

    R. Rusack

    Installation is under way of the last piece of the electromagnetic calorimeter. This is the preshower (ES) that sits in front of the two endcap calorimeters. The construction of the ES was completed in December and went through a detailed set of tests in December and January. The two preshower detectors have a total of 4300 silicon sensors with 137,000 strips. After final assembly and system testing in January, only two of the strips were found to be defective. Once CMS was fully opened a new support structure (‘Gazprom’) was put into place underneath the beam pipe, to support the Surkov platform, on which the preshower installation takes place. In the early hours of 26th February the first two Dees, which form the ‘ES+’ endcap,  were transported to P5 , a journey that took two and a half hours. The Dees, still inside environmental protection boxes, were then lowered  underground and moved to the ‘+’ end of CMS. Installation start...

  17. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Central Calorimeter (HB/HE/HO) Photodetectors The main activity of the HCAL group during the present shutdown is the replacement of a small fraction of the Central Calorimeter (HB/HE/HO) photodetectors -- the Hybrid Photo-Detectors (HPDs). During the MTCC of 2006 it was established that all HPDs exhibit a low rate of discharge generating large random pulses. This behaviour persists at the full CMS field. However, at relatively low fields (0.5 Tesla) this discharge rate increases dramatically and becomes very large for a fraction of the HPDs. The HO HPDs which sit in the gap of the return yoke are thus adversly affected. These discharge pulses have been labelled "HPD noise" (which must be distinguished from low level electronic noise which manifests itself as pedestal noise for all HPD readout channels). Additional intermediate level noise can be generated by ion-feedback arising from thermal and field emission electrons. Ion feedback noise never exceeds the equivalent of few 10s of GeV, the...

  18. The LHCb hadron calorimeter

    International Nuclear Information System (INIS)

    Dzhelyadin, R.I.

    2002-01-01

    The Hadron Calorimeter (HCAL) is designed for the LHCb experiment. The main purpose of the detector is to provide data for the L0 hadron trigger. The HCAL is designed as consisting of two symmetric movable parts of about 500 ton in total getting in touch in operation position without non-instrumented zones. The lateral dimensions of an active area are X=8.4 m width, Y=6.8 m height, and is distanced from the interaction point at Z=13.33 m. Both halves are assembled from stacked up modules. An internal structure consisting of thin iron plates interspaced with scintillating tiles has been chosen. Attention is paid to optimize the detector according to the requirements of the experiment, reducing the spending needed for its construction. Different construction technologies are being discussed. The calorimeter properties have been extensively studied with a variety of prototype on the accelerator beam. The calibration with a radioactive source and module-0 construction experience is discussed

  19. Phosphorylation events implicating p38 and PI3K mediate tungstate-effects in MIN6 beta cells

    International Nuclear Information System (INIS)

    Piquer, Sandra; Barcelo-Batllori, Silvia; Julia, Marta; Marzo, Nuria; Nadal, Belen; Guinovart, Joan J.; Gomis, Ramon

    2007-01-01

    Oral administration of sodium tungstate is an effective treatment for diabetes in animal models. Several lines of evidence indicate the pancreatic beta cell as one of the targets of tungstate action. Here, we examined the molecular mechanism by which this compound exerts its effects on the beta cell line MIN6. Tungstate treatment induced phosphorylation and subsequent activation of p38 and PI3K which in turn are implicated in tungstate PDX-1 nuclear localization and activation. Although no effect was observed in glucose-induced insulin secretion we found that tungstate activates basal insulin release, a process driven, at least in part, by activation of p38. These results show a direct involvement of p38 and PI3K phosphorylation in the mechanism of action of tungstate in the beta cell

  20. Some peculiarities of zirconium tungstate synthesis by thermal decomposition of hydrothermal precursors

    Energy Technology Data Exchange (ETDEWEB)

    Gubanov, Alexander I., E-mail: gubanov@niic.nsc.su [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, Akad. Lavrentiev Prospekt 3, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, Pirogova str. 2, 630090 Novosibirsk (Russian Federation); Dedova, Elena S. [Institute of Strength Physics and Materials Science, Siberian Branch of the Russian Academy of Sciences, pr. Akademicheskii 2/4, 634021 Tomsk (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk (Russian Federation); Plyusnin, Pavel E.; Filatov, Eugeny Y. [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, Akad. Lavrentiev Prospekt 3, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, Pirogova str. 2, 630090 Novosibirsk (Russian Federation); Kardash, Tatyana Y. [Boreskov Institute of Catalysis, Siberian Branch of the Russian Academy of Sciences, Akad. Lavrentiev Prospekt 5, 630090 Novosibirsk (Russian Federation); Korenev, Sergey V. [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, Akad. Lavrentiev Prospekt 3, 630090 Novosibirsk (Russian Federation); Novosibirsk State University, Pirogova str. 2, 630090 Novosibirsk (Russian Federation); Kulkov, Sergey N. [Institute of Strength Physics and Materials Science, Siberian Branch of the Russian Academy of Sciences, pr. Akademicheskii 2/4, 634021 Tomsk (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk (Russian Federation)

    2014-12-10

    Highlights: • Synthesis of ZrW{sub 2}O{sub 8} using hydrothermal method. • On hydrothermal synthesis optimal conc. of HCl in the reaction mixture is 2.3 M. • Thermal decomposition of ZrW{sub 2}O{sub 7}((OH){sub 1.5},Cl{sub 0.5})·2H{sub 2}O begins are 200 °S. • Amorphous intermediate crystallizes into cubic single-phase ZrW{sub 2}O{sub 8} above 550 °S. • ZrW{sub 2}O{sub 8} destructed at temperatures above 700 °S. - Abstract: This article discusses some peculiarities of the synthesis of ZrW{sub 2}O{sub 8} (1) using thermal decomposition of the precursor ZrW{sub 2}O{sub 7}((OH){sub 1.5},Cl{sub 0.5})·2H{sub 2}O (2) prepared by hydrothermal method. On hydrothermal synthesis of 2 the optimal concentration of hydrochloric acid in the reaction mixture is about 2.3 M. TG approach to determine the chemical composition of the precursor was suggested. It has been found that the precursor for the synthesis of zirconium tungstate has chemical formula 2. Thermal decomposition of the precursor 2 begins at 200 °S and affords an amorphous intermediate, which crystallizes as a cubic phase 1 above 550 °S with an exoeffect. The temperature of the beginning of the transition from amorphous to the crystalline state is 350 ± 25 °S.

  1. CMS hadronic forward calorimeter

    International Nuclear Information System (INIS)

    Merlo, J.P.

    1998-01-01

    Tests of quartz fiber prototypes, based on the detection of Cherenkov light from showering particles, demonstrate a detector possessing all of the desirable characteristics for a forward calorimeter. A prototype for the CMS experiment consists of 0.3 mm diameter fibers embedded in a copper matrix. The response to high energy (10-375 GeV) electrons, pions, protons and muons, the light yield, energy and position resolutions, and signal uniformity and linearity, are discussed. The signal generation mechanism gives this type of detector unique properties, especially for the detection of hadronic showers: Narrow, shallow shower profiles, hermeticity and extremely fast signals. The implications for measurements in the high-rate, high-radiation LHC environment are discussed. (orig.)

  2. Nemo-3 calorimeter electronics

    International Nuclear Information System (INIS)

    Bernaudin, P.; Cheikali, C.; Lavigne, B.; Richard, A.; Lebris, J.

    2000-11-01

    The calorimeter electronics of the NEMO-3 double beta decay experiment fulfills three functions: -energy measurement of the electrons by measuring the charge of the pulses, - time measurement, - fast first level triggering. The electronics of the 1940 Scintillator-PM modules is implemented as 40 '9U x 400 mm VME' boards of up to 51 channels. For each channel the analog signals conditioning is implemented as one SMD daughter board. Each board performs 12 bit charge measurements with 0.35 pC charge resolution, 12 bit time measurements with 50 ps time resolution and a fast analog multiplicity level for triggering. The total handling and conversion time for all the channels is less than 100 μs. The electronics will be presented as well as the test system. (authors)

  3. D0 calorimeter electronics

    International Nuclear Information System (INIS)

    Schamberger, R.D.

    1991-01-01

    A detailed description of the electronics used to readout the signals from the D0 Uranium-Liquid Argon Calorimeter is presented. The three major components of the readout system are the charge sensitive preamps, the shaping and sample and hold circuits, and the Analog to Digital converters. The very low noise preamps achieve an input noise equivalent to 2000e's + 3000e's per nanofarad of input capacitance. The coherent noise in the system is very low, less than 1/20 of an ADC count which is equivalent to about 200 KeV of energy incident on the detector. The ADC system contains a 12 bit, 5 μsecond successive approximation digitizer. We maintain a 15 bit dynamic range by automatically amplifying small signals after they are held, but before digitization. The ADC also contains pedestal and limit memory, to allow (on a channel by channel basis) offset subtraction, and suppression of small signals, symmetrically around zero signal. (orig.)

  4. Cerenkov fiber sampling calorimeters

    International Nuclear Information System (INIS)

    Arrington, K.; Kefford, D.; Kennedy, J.; Pisani, R.; Sanzeni, C.; Segall, K.; Wall, D.; Winn, D.R.; Carey, R.; Dye, S.; Miller, J.; Sulak, L.; Worstell, W.; Efremenko, Y.; Kamyshkov, Y.; Savin, A.; Shmakov, K.; Tarkovsky, E.

    1994-01-01

    Clear optical fibers were used as a Cerenkov sampling media in Pb (electromagnetic) and Cu (hadron) absorbers in spaghetti calorimeters, for high rate and high radiation dose experiments, such as the forward region of high energy colliders. The fiber axes were aligned close to the direction of the incident particles (1 degree--7 degree). The 7 λ deep hadron tower contained 2.8% by volume 1.5 mm diameter core clear plastic fibers. The 27 radiation length deep electromagnetic towers had packing fractions of 6.8% and 7.2% of 1 mm diameter core quartz fibers as the active Cerenkov sampling medium. The energy resolution on electrons and pions, energy response, pulse shapes and angular studies are presented

  5. Progress status for the Mu2e calorimeter system

    International Nuclear Information System (INIS)

    Pezzullo, Gianantonio; Cervelli, F; Budagov, J; Davydov, Yu; Glagolev, V; Carosi, R; Cheng, C; Echenard, B; Hitlin, D; Martini, M; Ongmonkolkul, P; Porter, F; Cordelli, M; Corradi, G; Giovannella, S; Happacher, F; Luca, A; Miscetti, S; Saputi, A; Murat, P

    2015-01-01

    The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful μ/e particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ∼ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ∼ < 1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal BaF 2 crystals of 20 cm length. Each crystal is readout by two large area APD's. In this paper, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment

  6. Systematic Study of the PbWO4 Crystal Short Term Instalibity Under Irradiation

    CERN Document Server

    Annenkov, Alexander; Chipaux, Rémi; Drobychev, Gleb; Fedorov, Andrey; Géléoc, Marie; Golubev, Nikolai; Korzhik, Mikhail; Lecoq, Paul; Ligun, A B; Missevitch, Oleg; Pavlenko, V B; Peigneux, Jean-Pierre; Singovsky, Alexander

    1997-01-01

    The effect of the irradiation on the lead tungstate ( PWO) scintillator properties has been studied at different irradiation facilities. Lead tungstate crystals grown with the tuning of oxides content in the melt to the stoichiometry of pure sheelite or sheelite-like type crystals and doped with heterovalent, trivalent and pentavalent impurities have been studied in order to optimize their resistance to irradiation. A combination of a selective cleaning of raw materials, a tuning of the melt from crystallization to crystallisation, and a destruction or compensation of the point structure defects has been used to minimize the short-term instability of PWO parameters under irradiation.

  7. Electromagnetic shower detector-calorimeters

    International Nuclear Information System (INIS)

    Appel, J.A.

    1975-01-01

    A brief review of the state-of-the-art of electromagnetic calorimeters is presented. The choice of detector based on the experimental requirements in cost, spatial resolution, energy resolution, and hadron rejection is discussed

  8. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    Crystals and Bare Supermodules Thanks to an unprecedented delivery rate, in excess of 1200 crystals per month during the last three months, the last Barrel crystals will be delivered at the end of February. The penultimate bare supermodule is under assembly; the last should be assembled in April. The first batch of Endcap crystals from the mass production has been received from China as well as two pre-series of 100 crystals from Russia. Electronics The assembly and test of off-detector electronics crates (each crate containing three triplets, each triplet comprising Data Concentrator Cards (DCC), Clock & Control System card (CCS) and Trigger & Clock Controllers (TCCs) module – i.e. enough to serve three supermodules) is progressing fast. Several crates have already been installed in the USC at point 5. The production of the specific Endcap electronics is also well advanced. For example, the test of the Front-End cards was recently completed. Electronics integration In early Autu...

  9. New approach to the readout system for a very large bismuth germanate calorimeter

    International Nuclear Information System (INIS)

    Sumner, R.

    1982-01-01

    This note presents a possible solution to the problem of data acquisition and control for a very large array of BGO crystals. The array is a total energy calorimeter, which is a part of a detector being designed for LEPC. After a brief description of the environment, we present a working definition of the calorimeter, followed by a statement of the desirable characteristics of the readout system. After a discussion of some alternatives, a complete system is described

  10. Tungstate-targeting of BKαβ1 channels tunes ERK phosphorylation and cell proliferation in human vascular smooth muscle.

    Directory of Open Access Journals (Sweden)

    Ana Isabel Fernández-Mariño

    Full Text Available Despite the substantial knowledge on the antidiabetic, antiobesity and antihypertensive actions of tungstate, information on its primary target/s is scarce. Tungstate activates both the ERK1/2 pathway and the vascular voltage- and Ca2+-dependent large-conductance BKαβ1 potassium channel, which modulates vascular smooth muscle cell (VSMC proliferation and function, respectively. Here, we have assessed the possible involvement of BKαβ1 channels in the tungstate-induced ERK phosphorylation and its relevance for VSMC proliferation. Western blot analysis in HEK cell lines showed that expression of vascular BKαβ1 channels potentiates the tungstate-induced ERK1/2 phosphorylation in a Gi/o protein-dependent manner. Tungstate activated BKαβ1 channels upstream of G proteins as channel activation was not altered by the inhibition of G proteins with GDPβS or pertussis toxin. Moreover, analysis of Gi/o protein activation measuring the FRET among heterologously expressed Gi protein subunits suggested that tungstate-targeting of BKαβ1 channels promotes G protein activation. Single channel recordings on VSMCs from wild-type and β1-knockout mice indicated that the presence of the regulatory β1 subunit was essential for the tungstate-mediated activation of BK channels in VSMCs. Moreover, the specific BK channel blocker iberiotoxin lowered tungstate-induced ERK phosphorylation by 55% and partially reverted (by 51% the tungstate-produced reduction of platelet-derived growth factor (PDGF-induced proliferation in human VSMCs. Our observations indicate that tungstate-targeting of BKαβ1 channels promotes activation of PTX-sensitive Gi proteins to enhance the tungstate-induced phosphorylation of ERK, and inhibits PDGF-stimulated cell proliferation in human vascular smooth muscle.

  11. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  12. crystal

    Science.gov (United States)

    Yu, Yi; Huang, Yisheng; Zhang, Lizhen; Lin, Zhoubin; Sun, Shijia; Wang, Guofu

    2014-07-01

    A Nd3+:Na2La4(WO4)7 crystal with dimensions of ϕ 17 × 30 mm3 was grown by the Czochralski method. The thermal expansion coefficients of Nd3+:Na2La4(WO4)7 crystal are 1.32 × 10-5 K-1 along c-axis and 1.23 × 10-5 K-1 along a-axis, respectively. The spectroscopic characteristics of Nd3+:Na2La4(WO4)7 crystal were investigated. The Judd-Ofelt theory was applied to calculate the spectral parameters. The absorption cross sections at 805 nm are 2.17 × 10-20 cm2 with a full width at half maximum (FWHM) of 15 nm for π-polarization, and 2.29 × 10-20 cm2 with a FWHM of 14 nm for σ-polarization. The emission cross sections are 3.19 × 10-20 cm2 for σ-polarization and 2.67 × 10-20 cm2 for π-polarization at 1,064 nm. The fluorescence quantum efficiency is 67 %. The quasi-cw laser of Nd3+:Na2La4(WO4)7 crystal was performed. The maximum output power is 80 mW. The slope efficiency is 7.12 %. The results suggest Nd3+:Na2La4(WO4)7 crystal as a promising laser crystal fit for laser diode pumping.

  13. CsI Calorimeter for a Compton-Pair Telescope

    Science.gov (United States)

    Grove, Eric J.

    We propose to build and test a hodoscopic CsI(Tl) scintillating-crystal calorimeter for a medium-energy γ-ray Compton and pair telescope. The design and technical approach for this calorimeter relies deeply on heritage from the Fermi LAT CsI Calorimeter, but it dramatically improves the low-energy performance of that design by reading out the scintillation light with silicon photomultipliers (SiPMs), making the technology developed for Fermi applicable in the Compton regime. While such a hodoscopic calorimeter is useful for an entire class of medium-energy γ-ray telescope designs, we propose to build it explicitly to support beam tests and balloon flight of the Proto-ComPair telescope, the development and construction of which was funded in a four-year APRA program beginning in 2015 ("ComPair: Steps to a Medium Energy γ-ray Mission" with PI J. McEnery of GSFC). That award did not include funding for its CsI calorimeter subsystem, and this proposal is intended to cover that gap. ComPair is a MIDEX-class instrument concept to perform a high-sensitivity survey of the γ-ray sky from 0.5 MeV to 500 MeV. ComPair is designed to provide a dramatic increase in sensitivity relative to previous instruments in this energy range (predominantly INTEGRAL/SPI and Compton COMPTEL), with the same transformative sensitivity increase - and corresponding scientific return- that the Fermi Large Area Telescope provided relative to Compton EGRET. To enable transformative science over a broad range of MeV energies and with a wide field of view, ComPair is a combined Compton telescope and pair telescope employing a silicon-strip tracker (for Compton scattering and pair conversion and tracking) and a solid-state CdZnTe calorimeter (for Compton absorption) and CsI calorimeter (for pair calorimetry), surrounded by a plastic scintillator anti-coincidence detector. Under the current proposal, we will complete the detailed design, assembly, and test of the CsI calorimeter for the risk

  14. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  15. Progress in PbWO4 scintillating crystal

    International Nuclear Information System (INIS)

    Fyodorov, A.; Korzhik, M.; Missevitch, O.; Pavlenko, V.; Kachanov, V.; Singovsky, A.; Annenkov, A.N.; Ligun, V.A.; Peigneux, J.P.; Vialle, J.P.

    1994-12-01

    Lead tungstate PbWO 4 (PWO) has recently been shown to be a promising scintillating material for precise electromagnetic calorimetry. Modifications of PWO technology were made to improve the uniformity of the crystal properties. A model of the scintillation mechanism for PWO was developed and served to guide the improvement. The complex spectroscopic analysis of the crystal after improvement is presented, as well as the new crystal properties achieved. (K.A.). 14 refs., 14 figs., 4 tabs

  16. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL Barrel (EB) The main task during this fall was the connection of services of the ECAL Barrel Supermodules installed in the vacuum-tank. This work has been completed. The team is now commissioning the Supermodules using the final services (cables and optical fibers, HV and LV power supplies, cooling plant) and final electronics in the service cavern. The pace of commissioning has been limited by the availability of the cooling plant. At the time of writing, about 2/3 of the Supermodules had been signed off. ECAL Endcaps (EE) The Endcaps crystal production is proceeding fast. At the end of October, more than 10000 crystals (two thirds of the total quantity) had beem delivered. The Endcaps crystal production will be completed at the end of March 2008, as planned. The crystals testing and the gluing of the VPTs (Vacuum Photo Triodes) on the crystals follow the plan. The assembly of Supercrystals (a set of 25 crystals) is now a routine operation. All the Supercrystals for Dee1 and two thirds of those ne...

  17. Ammonium-tungstate-promoted growth of boron nitride nanotubes

    Science.gov (United States)

    E, Songfeng; Li, Chaowei; Li, Taotao; Geng, Renjie; Li, Qiulong; Lu, Weibang; Yao, Yagang

    2018-05-01

    Ammonium tungstate ((NH4)10W12O41 · xH2O) is a kind of oxygen-containing ammonium salt. The following study proves that it can be successfully used as a metal oxide alternative to produce boron oxide (B2O2) by oxidizing boron (B) in a traditional boron oxide chemical vapor deposition (BOCVD) process. This special oxidant promotes the simplistic fabrication of boron nitride nanotubes (BNNTs) in a conventional horizontal tube furnace, an outcome which may have resulted from its strong oxidizability. The experimental results demonstrate that the mole ratio of B and (NH4)10W12O41 · xH2O is a key parameter in determining the formation, quality and quantity of BNNTs when stainless steel is employed as a catalyst. We also found that Mg(NO3)2 and MgO nanoparticles (NPs) can be used as catalysts to grow BNNTs with the same precursor. The BNNTs obtained from the Mg(NO3)2 catalyst were straighter than those obtained from the MgO NP catalyst. This could have been due to the different physical forms of the catalysts that were used.

  18. Synthesis of lanthanum tungstate interconnecting nanoparticles by high voltage electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Keereeta, Yanee, E-mail: ynkeereeta@gmail.com [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thongtem, Titipun, E-mail: ttpthongtem@yahoo.com [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thongtem, Somchai [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2015-10-01

    Graphical abstract: - Highlights: • La{sub 2}(WO{sub 4}){sub 3} as one of semiconducting materials. • H.V. electrospinning was used to synthesize La{sub 2}(WO{sub 4}){sub 3} interconnecting nanoparticles. • A promising material for photoemission. - Abstract: Lanthanum tungstate (La{sub 2}(WO{sub 4}){sub 3}) interconnecting nanoparticles in the shape of fibers were successfully synthesized by electrospinning in combination with high temperature calcination. In this research, calcination temperature for the synthesis of the fibers evidently influenced the diameter, morphology and crystalline degree. The crystalline monoclinic La{sub 2}(WO{sub 4}){sub 3} fibers with 200–700 nm in diameter, two main Raman peaks at 945 and 927 cm{sup −1}, FTIR stretching modes at 936 and 847 cm{sup −1}, 2.02 eV energy gap and 415–430 nm blue emission were synthesized by calcination of inorganic/organic hybrid fibers at 750 °C for 5 h, characterized by X-ray diffraction, scanning electron microscopy (SEM), transmission electron microscopy (TEM), selected area electron diffraction (SAED), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, UV–visible spectroscopy and photoluminescence (PL) spectroscopy. The surface of the composite fibers before calcination was very smooth. Upon calcination the composite fibers at 750 °C for 5 h, they were transformed into nanoparticles join together in the shape of fibers with rough surface.

  19. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    All the HCAL calorimeters are ready for data-taking in 2011 and participated fully in the cosmic running and initial beam operations in the last few weeks. Several improvements were made during the winter technical stop, including replacement of the light-guide sleeves in HF, improvements to the low voltage power connections, and separation of HF from HB and HE in the DAQ partitions. During the 2010 running a form of anomalous noise in the HF was identified as being caused by scintillation when charged particles pass through a portion of the air light-guide sleeve. This portion was constructed from a non-conductive mirror-like material called “HEM”. To suppress these anomalous signals, during the recent winter technical stop all sleeves in the detector were replaced with sleeves made of Tyvek. The detector has been recommissioned with all channels fully operational. Recalibration of the detector will be required due to the differing reflectivity of the new sleeves compared with the HEM sl...

  20. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    D. Green

    The organization of CMS HCAL contains four “geographic” efforts, HB, HO, HE and HF. In addition there are presently five “common” HCAL activities. These ef¬forts are concentrated on electronics, on controls (DCS), on physics objects (JetMet), on Installation and Commissioning (I&C), and on Test Beam (TB) and Cosmic Challenge (MTCC) data taking. HCAL has begun planning to re-organize to be synchronized with the overall CMS management structure. HF The full production of the wedges is completed for some time. The 2004 test beam work has established the radioactive source calibration system for HF works at the 5 % level or better and a note is completed. The calibration of the complete HF is complete. HF is now in the UX cavern and will be hooked up and read out as soon as the services are available. HE The two HE calorimeters are installed and an initial calibration has been established. In the MTCC the HE was read out and muon data was observed. Event b...

  1. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding and A. Skuja

    2010-01-01

    Splash and Collision Data HCAL recorded the beam-on-collimator (splash) and the first collision data in November and December 2009, and provided triggers to CMS with the forward calorimeter, HF. Splash events were used to improve the energy inter-calibration of the HB and HE channels, with the basic assumption that the energy deposited in the detector by the large flux of muons that passed through in splash events was a smooth function in eta and phi. The new HB and HE calibration coefficients were applied prior to the collision data taking. For HO, a similar analysis is being finalized. Splash events were also used to determine the relative timing between channels in HB and HE, and new delay settings were calculated based on splashes from one beam, applied and verified with the splash events from the other beam. During Fall 2009, the HF technical trigger was improved in order to be effectively used as one of the main CMS triggers during the collision data taking. Collisions were successfully recorded by all...

  2. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    by J. Spalding and A. Skuja

    2010-01-01

    Operations and Maintenance All HCAL sub-detectors participated throughout the recent data taking with 7 TeV collisions. A timing scan of HF was performed to optimize the timing across the detectors and to set the overall time position of the ~10-ns wide signals within the 25-ns integration time slice. This position was chosen to ensure that the trigger primitives in physics events are generated synchronously at the desired bunch crossing, while also providing discrimination between the calorimeter signals and anomalous signals due to interactions within the photomultiplier tubes. This timing discrimination is now used in the standard filter algorithms for anomalous signals. For HB and HE, once the statistics needed to assess the timing of a sufficient number of channels was accumulated, it was verified that the time settings determined with cosmic, splash events and initial collision data were appropriate for the 7 TeV collision data taking. A further fine-tuning of the HB and HE time settings will be perfo...

  3. Calorimeter Process Variable Archiving

    International Nuclear Information System (INIS)

    Huffman, David

    2002-01-01

    These steps were taken to maintain weekly archives: (1) Friday morning you stop the archiver and wait for it to finish writing data (the lock file will be removed from the directory); (2) move the current archive information to a PC via FTP; (3) remove all previous archive information in the previous directory; (4) move the current archive into the previous directory; (5) start a new archive; (6) burn a CDROM of the archive; and (7) copy the current archive to a specific directory. There are 2 ways to check if the Calorimeter Archiver is running, either through the WEB based front end or directly from a command line. Once the archiver is running it can be monitored from a WEB page. This only works with a browser launched from the online machine running the archiver. Each time the browser is reloaded there should be an update reported in the last write check field. You might have to wait a few minutes to see the update. Calorimetry currently takes readings every (300 sec.) 5 minutes. The second method to verify the archiver is running is to issue a command from a Linux cluster machine.

  4. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    During the last 3 months commissioning of HCAL has continued for HO and HE+. We have also started the commissioning of the first wedge of HB+. Progress continues to be made by our Trigger/DAQ, DCS and DPG colleagues. HF will be used to obtain a Luminosity measurement for CMS. A first test of the modifications to the HF electronics was made in the August CMS global run. In addition to installation and commissioning of various parts of HCAL, we also completed a very successful summer Test Beam period which saw measurements of the combined HE/EE/ES calorimeter system in the H2 test beam. Installation and Commissioning a. HB commissioning This week, part of the final water-cooling system for HB was commissioned. Eighteen HB- wedges and two pilot wedges on HB+ have been connected to the water circuit on YB0. On Sept 6, 2007 cabling and commissioning was started for the first HB readout box (RBX) using temporary set of cables. We have connected RBX-17 to the Low Voltage PS and the HCAL Detector Control Sy...

  5. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Since the beginning of 2007, HCAL has made significant progress in the installation and commissioning of both hardware and software. A large fraction of the physical Hadron Calorimeter modules have been installed in UX5. In fact, the only missing pieces are HE- and part of HO. The HB+/- were installed in the cryostat in March. HB scintillator layer-17 was installed above ground before the HB were lowered. The HB- scintillator layer-0 was installed immediately after completion of EB- installation. HF/HCAL Commissioning The commissioning and checkout of the HCAL readout electronics is also proceeding at a rapid pace in Bldg. 904 and USC55. All sixteen crates of HCAL VME readout electronics have been commissioned and certified for service. Fifteen are currently operating in the S2 level of USC55. The last crate is being used for firmware development in the Electronics Integration Facility in 904. All installed crates are interfaced to their VME computers and receive synchronous control from the fully-equipp...

  6. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    Throughout the entire proton-proton run of 2011, all HCAL calorimeters operated very efficiently. Over 99% of HCAL readout and trigger channels were alive. However, during the year we did face two hardware problems. One major operation problem was the occasional loss of data from a single RBX caused by single event upsets (SEUs). The rate of RBX data loss was on average one incident per 10 pb–1 of integrated luminosity. This led to approximately 1% of CMS data loss. In order to mitigate this problem, HCAL has introduced an automatic reset of the RBX. With this reset, full operation was restored within about one minute. The final hardware correction of the problem will be possible only during a long shutdown (LS1) in 2013-’14. Another hardware problem that developed in 2011 was the failure of QPLL (quartz phase lock loops) chips. This led to the loss of phase of the readout clock with respect to the LHC clock. As a consequence, in two sections in HCAL (10 degree in φ on HB and 1...

  7. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    HCAL installation and commissioning is approaching completion. Work continues on commissioning of HE-, HF- and the minus wheels of HO. We expect that all commissioning will be completed by mid-March. HCAL commissioning is interleaved with integration of HCAL and the Global Calorimeter Trigger (GCT). HCAL is attempting to take data using the HPD self-trigger as part of the GCT trigger path. Initial attempts in mid-February have not succeeded. Work continues on HCAL and the GCT. HPD lifetimes at 4 Tesla are being measured in Princeton. After more than a month of testing in a 4 Tesla field there are no sur¬prises. As the lifetime measurements proceed, the HPD response at intermediate fields of 1 Tesla will be verified and analyzed. Work also continues on HCAL calibration and DCS/DSS at Point 5. More details for some of the subsystems are presented in what follows. HE HE plus The cooling system of HE+ is functional now. The HE+ final connections to the LV system are complete. LV and HV tests to ev...

  8. The CPLEAR Electromagnetic Calorimeter

    CERN Document Server

    Adler, R; Bal, F; Behnke, O; Bloch, P; Damianoglou, D; Dechelette, Paul; Dröge, M; Eckart, B; Felder, C; Fetscher, W; Fidecaro, Maria; Garreta, D; Gerber, H J; Gumplinger, P; Guyon, D; Johner, H U; Löfstedt, B; Kern, J; Kokkas, P; Krause, H; Mall, U; Marin, C P; Nanni, F; Pagels, B; Pavlopoulos, P; Petit, P; Polivka, G; Rheme, C; Ruf, T; Santoni, C; Schaller, L A; Schopper, A; Tauscher, Ludwig; Tschopp, H; Weber, P; Wendler, H; Witzig, C; Wolter, M

    1997-01-01

    A large-acceptance lead/gas sampling electromagnetic calorimeter (ECAL) was constructed for the CPLEAR experiment to detect photons from decays of $\\pi^0$s with momentum $p_{\\pi^0} \\le 800$ MeV$/c$. The main purpose of the ECAL is to determine the decay vertex of neutral-kaon decays $\\ko \\rightarrow \\pi^0\\pi^0 \\rightarrow 4 \\gamma$ and $\\ko \\rightarrow \\pi^0\\pi^0\\pi^0 \\rightarrow 6 \\gamma$. This requires a position-sensitive photon detector with high spatial granularity in $r$-, $\\varphi$-, and $z$-coordinates. The ECAL --- a barrel without end-caps located inside a magnetic field of 0.44 T --- consists of 18 identical concentric layers. Each layer of $1/3$ radiation length (X${_0}$) contains a converter plate followed by small cross-section high-gain tubes of 2640 mm active length which are sandwiched by passive pick-up strip plates. The ECAL, with a total of $6$ X${_0}$, has an energy resolution of $\\sigma (E)/E \\approx 13\\% / \\sqrt{E(\\mathrm{GeV})}$ and a position resolution of 4.5 mm for the shower foot. ...

  9. Production of barium molybdate and tungstate on the base of ternary reciprocal Na, Ba long Cl, EhO4 (Eh - Mo, W) systems

    International Nuclear Information System (INIS)

    Garkushin, I.K.; Sechnoj, A.I.; Dibirov, M.A.; Trunin, A.S.

    1984-01-01

    Possibilities of the syntnesis of barium molybdate and tungstate on the base of ternary reciprocal Na, Ba parallel Cl, EhO 4 (Eh=Mo, W) system state diagrams are under study. It is shown that on the basis of these reciprocal state diagrams syntnesis of not only BaO 4 but also of other suhstances is possible. Purity of obtained chemical agents is basically dependent on qualification of initial components. Synthesis temperature is decreased and time is reduced as compared to other known methods. For substance synthesis, state diagrams examination (reaction type confirmation and component crystallization fields separation from compound crystallization fields) is necessary along with the calculation of the conventional thermochemical effect

  10. High precision electromagnetic calorimetry with 40 MHz readout: the CMS crystal ECAL for the High-Luminosity LHC

    CERN Document Server

    Orimoto, Toyoko Jennifer

    2017-01-01

    The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) will be upgraded to meet the challenging running conditions expected after the High-Luminosity upgrade of the LHC (HL-LHC). Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. The detector will have to sustain an instantaneous luminosity of above $5 \\times 10^{34} cm^2 s^{-1}$, maintaining a performance similar to the one of LHC Run I for an integrated luminosity of 3 to 5 $ab^{-1}$. This poses stringent requirements on the radiation resistance of detector components, the readout and data transfer from the front end to the back end electronics, as well as the latency of the trigger system. The barrel region of the CMS ECAL will be able to retain the current lead tungstate crystals and avalanche photodiode detectors which will meet the energy measurement performance requirements throughout t...

  11. Investigation of behaviour of iron (3) microimpurity in ammonium tungstate solutions

    International Nuclear Information System (INIS)

    Vasil'ev, M.A.; Taushkanov, V.P.; Rumyantsev, V.K.; Andronov, E.A.

    1978-01-01

    To determine the purification optimum conditions of ammonium tungstate concentrated solutions from iron(3) microimpurities the behaviour of iron(3) with 10 -5 -10 -4 mol/l concentration in these solutions is studied. Concentration of hydrolyzed iron forms has been determined by spectrophotometric and radiometric methods. It is stated, that the processes of hydrolysis and aggregation of dispersed-colloid iron particles in tungstate solutions is generally over during the first 50 hours. It is shown, that a part of iron hydroxide particles of dimension less than 200 A increases with ammonium tungstate concentration increasing. Residual iron concentration also increases under the same conditions. The increasing of efficiency of solution purification is due to decreasing of carbon dispersion, applied for this purpose, and also modification of their surface by hydroxides of multivalent metas as zirconium for example

  12. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    Crystals and Bare Supermodules The last Barrel crystal was delivered on March 9th and the last (36th) Bare Supermodule was completed by April 20th. Endcaps crystal production is ramping up at both producers and the delivery rate exceeds already 1050 crystals per month. The quality of the Endcaps crystals is similar to that of the Barrel. Electronics The production of the on-detector electronics (Barrel + Endcaps) is complete. Already 10 out of the 12 crates of the Barrel Off-detector modules have been commissioned and installed in the CMS service cavern, and the integration with the global DAQ is progressing fast. The last 2 crates will be completed in August, after reception of the last Trigger Modules TCC68. The installation of the High Voltage is also progressing well, taking into account that some HV supplies are still used in the various assembly and test centres of ECAL. A large fraction of the low voltage supplies has been delivered and tested. Electronics integration As explained in the Febru...

  13. Structural characterization of hydrogen separating membranes based on lanthanide-tungstates

    International Nuclear Information System (INIS)

    Scherb, Tobias

    2011-01-01

    The global energy supply is currently the most controversial issue discussed in our society. Despite the increasing importance of renewable energies, the largest portion of electrical energy has its origin in fossil fuels. CO 2 , emitted during combustion in power plants is known to be one of the greenhouse gases that contributes significantly to global climate change. The development of technologies for environmentally friendly power generation from coal and gas is an area of significant interest. One possibility is the capture and long-term storage of CO 2 from the exhaust stream of fossil fuel power plants. In the pre-combustion process, CO 2 and H 2 can be separated after gasification of the fossil fuel. For this purpose gas-tight ceramic membranes with mixed electronic-protonic conductivity can be used. However, these materials have high requirements due to the extreme conditions in power plants. Mixed electronic-protonic conducting lanthanide tungstates (Ln 6 WO 12 Ln = lanthanide or yttrium) are promising materials, which are stable in CO 2 -containing harsh environments. This work presents a study on structure-property relationships of Ln 6 WO 12 . The structural analysis was performed by the use of neutron and high-resolution X-ray diffraction methods for three exemplary systems (Ln = La, Nd, Y). Samples were prepared via solid state reaction (SSR), and also via a sol-gel approach (Pechini). For the systems LaWO and NdWO, new structural models were developed by combined Rietveld analysis and Fourier density maps. The latter was applied to determine the electron and nuclear density distribution. LaWO with a La/W ratio from 5.3 to 5.7 crystallizes with the space group F-43m and forms a superstructure due to a partially ordered arrangement of cations. On Wyckoff site 48h, up to 4.6 % W can be substituted by La. The oxygen atoms around tungsten are highly delocalized and 6 out of 24 possible split positions are occupied. Thus, W has an octahedral coordination

  14. Thermal dynamics of bomb calorimeters.

    Science.gov (United States)

    Lyon, Richard E

    2015-12-01

    The thermal dynamics of bomb calorimeters are modeled using a lumped heat transfer analysis in which heat is released in a pressure vessel/bomb immersed in a stirred water bath that is surrounded by a static air space bounded by an insulated (static) jacket, a constant/controlled temperature jacket (isoperibol), or a changing temperature (adiabatic) jacket. The temperature history of the water bath for each of these boundary conditions (methods) is well described by the two-term solution for the calorimeter response to a heat impulse (combustion), allowing the heat transfer coefficients and thermal capacities of the bomb and water bath to be determined parametrically. The validated heat transfer model provides an expression for direct calculation of the heat released in an arbitrary process inside a bomb calorimeter using the temperature history of the water bath for each of the boundary conditions (methods). This result makes possible the direct calculation of the heat of combustion of a sample in an isoperibol calorimeter from the recorded temperature history without the need for semi-empirical temperature corrections to account for non-adiabatic behavior. Another useful result is that the maximum temperature rise of the water bath in the static jacket method is proportional to the total heat generated, and the empirical proportionality constant, which is determined by calibration, accounts for all of the heat losses and thermal lags of the calorimeter.

  15. The ATLAS Level-1 Calorimeter Trigger

    International Nuclear Information System (INIS)

    Achenbach, R; Andrei, V; Adragna, P; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J P; Asman, B; Bohm, C; Ay, C; Bauss, B; Bendel, M; Dahlhoff, A; Eckweiler, S; Booth, J R A; Thomas, P Bright; Charlton, D G; Collins, N J; Curtis, C J

    2008-01-01

    The ATLAS Level-1 Calorimeter Trigger uses reduced-granularity information from all the ATLAS calorimeters to search for high transverse-energy electrons, photons, τ leptons and jets, as well as high missing and total transverse energy. The calorimeter trigger electronics has a fixed latency of about 1 μs, using programmable custom-built digital electronics. This paper describes the Calorimeter Trigger hardware, as installed in the ATLAS electronics cavern

  16. The ATLAS Level-1 Calorimeter Trigger

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, R; Andrei, V [Kirchhoff-Institut fuer Physik, University of Heidelberg, D-69120 Heidelberg (Germany); Adragna, P [Physics Department, Queen Mary, University of London, London E1 4NS (United Kingdom); Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J P [STFC Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, Oxon OX11 0QX (United Kingdom); Asman, B; Bohm, C [Fysikum, Stockholm University, SE-106 91 Stockholm (Sweden); Ay, C; Bauss, B; Bendel, M; Dahlhoff, A; Eckweiler, S [Institut fuer Physik, University of Mainz, D-55099 Mainz (Germany); Booth, J R A; Thomas, P Bright; Charlton, D G; Collins, N J; Curtis, C J [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom)], E-mail: e.eisenhandler@qmul.ac.uk (and others)

    2008-03-15

    The ATLAS Level-1 Calorimeter Trigger uses reduced-granularity information from all the ATLAS calorimeters to search for high transverse-energy electrons, photons, {tau} leptons and jets, as well as high missing and total transverse energy. The calorimeter trigger electronics has a fixed latency of about 1 {mu}s, using programmable custom-built digital electronics. This paper describes the Calorimeter Trigger hardware, as installed in the ATLAS electronics cavern.

  17. Periodic Sorption of Tungstate Ions on Anionite AV-17-8

    Directory of Open Access Journals (Sweden)

    D’yachenko Aleksandr

    2017-01-01

    Full Text Available The multiple sorption of sodium tungstate resulting from the autoclave-soda digestion of a tungsten-bearing concentrate was studied using anion-exchange resin AV-17-8. The choice of ion exchange resin was carried out under static conditions using highly basic anionites. The sorption and desorption plots for tungstate and carbonate ions were demonstrated under dynamic conditions. The total dynamic capacity of the resin was estimated for each species of the ions in three sorption cycles. The applicability of the AV-17-8 resin as a sorbent in the autoclave-soda process flowsheet was determined.

  18. The CHORUS calorimeter: test results

    International Nuclear Information System (INIS)

    Buontempo, S.; Capone, A.; Cocco, A.G.; De Pedis, D.; Di Capua, E.; Dore, U.; Ereditato, A.; Ferroni, M.; Fiorillo, G.; Loverre, P.F.; Luppi, C.; Macina, D.; Mazzoni, M.A.; Migliozzi, P.; Palladino, V.; Piredda, G.; Riccardi, F.; Righini, P.P.; Saitta, B.; Santacesaria, R.; Strolin, P.; Zucchelli, P.

    1995-01-01

    In the framework of the CHORUS experiment for the search of ν μ ν τ oscillations at CERN, we have built the high resolution calorimeter, intended for the measurement of the energy of hadronic showers produced in neutrino interactions. The calorimeter consists of three parts. The first two are made of lead and plastic scintillating fibers in the volume ratio 4 : 1, such as to achieve compensation. The third is a sandwich of lead plates and scintillator strips in the same volume ratio. The techniques used for the construction of the calorimeter are described, as well as its performance in shower and muon detection. We used electron, pion and muon beams in the energy range 2-100 GeV for this purpose. (orig.)

  19. Role of sodium tungstate as a potential antiplatelet agent

    Directory of Open Access Journals (Sweden)

    Fernández-Ruiz R

    2015-05-01

    Full Text Available Rebeca Fernández-Ruiz,1,2 Marc Pino,3 Begoña Hurtado,4 Pablo García de Frutos,4 Carolina Caballo,3 Ginés Escolar,3 Ramón Gomis,1,2,5 Maribel Diaz-Ricart3 1Diabetes and Obesity Research Laboratory, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS, Rosellón, Barcelona, 2Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Barcelona, 3Hemotherapy–Hemostasis, Hospital Clínic, Universidad de Barcelona, IDIBAPS, Villarroel, Barcelona, 4Institutode Investigaciones Biomédicas de Barcelona, Consejo Superior de Investigaciones Científicas, Institut d’Investigacions Biomediques August Pi i Sunyer, Rosellón, Barcelona, 5Hospital Clinic, Universitat de Barcelona, Villarroel, Barcelona, Spain Purpose: Platelet inhibition is a key strategy in the management of atherothrombosis. However, the large variability in response to current strategies leads to the search for alternative inhibitors. The antiplatelet effect of the inorganic salt sodium tungstate (Na2O4W, a protein tyrosine phosphatase 1B (PTP1B inhibitor, has been investigated in this study.Methods: Wild-type (WT and PTP1B knockout (PTP1B-/- mice were treated for 1 week with Na2O4W to study platelet function with the platelet function analyzer PFA-100, a cone-and-plate analyzer, a flat perfusion chamber, and thrombus formation in vivo. Human blood aliquots were incubated with Na2O4W for 1 hour to measure platelet function using the PFA-100 and the annular perfusion chamber. Aggregometry and thromboelastometry were also performed.Results: In WT mice, Na2O4W treatment prolonged closure times in the PFA-100 and decreased the surface covered (%SC by platelets on collagen. Thrombi formed in a thrombosis mice model were smaller in animals treated with Na2O4W (4.6±0.7 mg vs 8.9±0.7 mg; P<0.001. Results with Na2O4W were similar to those in untreated PTP1B-/- mice (5.0±0.3 mg. Treatment of the PTP1B-/- mice with Na2O4W modified only

  20. Overview of the Calorimeter Readout Upgrades

    CERN Document Server

    Straessner, Arno; The ATLAS collaboration

    2018-01-01

    The ATLAS and CMS calorimeter electronics will be upgraded for the HL-LHC data taking phase to cope with higher event pile-up and to allow improved trigger strategies. This presentations gives an overview of the ongoing developments for the CMS barrel calorimeters and the ATLAS LAr and Tile calorimeters.

  1. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  2. Some possible improvements in scintillation calorimeters

    International Nuclear Information System (INIS)

    Lorenz, E.

    1985-03-01

    Two ideas for improvements of scintillation calorimeters will be presented: a) improved readout of scintillating, totally active electromagnetic calorimeters with combinations of silicon photodiodes and fluorescent panel collectors, b) use of time structure analysis on calorimetry, both for higher rate applications and improved resolution for hadron calorimeters. (orig.)

  3. Sodium Tungstate for Promoting Mesenchymal Stem Cell Chondrogenesis.

    Science.gov (United States)

    Khader, Ateka; Sherman, Lauren S; Rameshwar, Pranela; Arinzeh, Treena L

    2016-12-15

    Articular cartilage has a limited ability to heal. Mesenchymal stem cells (MSCs) derived from the bone marrow have shown promise as a cell type for cartilage regeneration strategies. In this study, sodium tungstate (Na 2 WO 4 ), which is an insulin mimetic, was evaluated for the first time as an inductive factor to enhance human MSC chondrogenesis. MSCs were seeded onto three-dimensional electrospun scaffolds in growth medium (GM), complete chondrogenic induction medium (CCM) containing insulin, and CCM without insulin. Na 2 WO 4 was added to the media leading to final concentrations of 0, 0.01, 0.1, and 1 mM. Chondrogenic differentiation was assessed by biochemical analyses, immunostaining, and gene expression. Cytotoxicity using human peripheral blood mononuclear cells (PBMCS) was also investigated. The chondrogenic differentiation of MSCs was enhanced in the presence of low concentrations of Na 2 WO 4 compared to control, without Na 2 WO 4 . In the induction medium containing insulin, cells in 0.01 mM Na 2 WO 4 produced significantly higher sulfated glycosaminoglycans, collagen type II, and chondrogenic gene expression than all other groups at day 28. Cells in 0.1 mM Na 2 WO 4 had significantly higher collagen II production and significantly higher sox-9 and aggrecan gene expression compared to control at day 28. Cells in GM and induction medium without insulin containing low concentrations of Na 2 WO 4 also expressed chondrogenic markers. Na 2 WO 4 did not stimulate PBMC proliferation or apoptosis. The results demonstrate that Na 2 WO 4 enhances chondrogenic differentiation of MSCs, does not have a toxic effect, and may be useful for MSC-based approaches for cartilage repair.

  4. Prototype study of a BGO electromagnetic calorimeter for the experiment L3

    International Nuclear Information System (INIS)

    El Mamouni, H.

    1986-01-01

    The L3 experiment detector at LEP is equipped with an original electromagnetic calorimeter. Such a calorimeter is made of a new calorimetric material, viz, Bismuth Germanate Oxyde (BGO). Furthermore, the scintillation light is read by means of large-area photodiodes. The latter choice for the photodiodes is dictated by the presence of a magnetic field. This thesis deals with the study in the 1-50 GeV energy range of the performances of a prototype for this new calorimeter. A great deal of efforts is devoted to ameliorate the energy resolution by improving the signal/noise ratio, the BGO crystals quality, the wrapping, the mechanical structure, etc... The goodness and the quality of the obtained results (concerning the linearity, the energy resolution and the position resolution) make it possible to reach in the near future the stage of the construction of a definitive calorimeter [fr

  5. A crystal barrel

    CERN Multimedia

    2007-01-01

    The production of crystals for the barrel of the CMS electromagnetic calorimeter has been completed. This is an important milestone for the experiment, which received the last of its 62,960 crystals on 9 March. The members of the team responsible for the crystal acceptance testing at CERN display the last crystal for the CMS electromagnetic calorimeter barrel. From left to right: Igor Tarasov, Etiennette Auffray and Hervé Cornet.One of the six machines specially developed to measure 67 different parameters on each crystal. Igor Tarasov is seen inserting the last batch of crystals into the machine. The last of the 62,960 CMS barrel crystals arrived at CERN on 9 March. Once removed from its polystyrene protection, this delicate crystal, like thousands of its predecessors, will be inserted into the last of the 36 supermodules of the barrel electromagnetic calorimeter in a few days' time. This marks the end of an important chapter in an almost 15-year-long journey by the CMS crystals team, some of whose member...

  6. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    Philippe Bloch

    ECAL Barrel (EB) Great progress has been achieved during the last few months on Barrel commissioning. All 36 supermodules have been run concurrently during the CRUZET in early May. The EB readout has reached the expected performance and is included regularly with central DAQ.  ECAL has been used as a source of triggers during cosmic runs. ECAL Endcaps (EE) Important milestones have been recently achieved: The Endcaps crystal production was completed in mid March. The gluing of the VPTs (Vacuum Photo Triodes) on the crystals, the assembly of Supercrystals (a set of 25 crystals) and their mounting on the Dee backplates (including the connection of the laser monitoring fibers) were finished during May. The mechanical assembly of the four endcap Dees is therefore completed. The assembly of the services and electronics on the backside of the Dees’ back-plates is also proceeding at a fast speed. The laying of the high voltage cables, the inner moderator, the optical fibers for the LED stabilit...

  7. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00223142; The ATLAS collaboration

    2017-01-01

    Current and future need for large scale simulated samples motivate the development of reliable fast simulation techniques. The new Fast Calorimeter Simulation is an improved parameterized response of single particles in the ATLAS calorimeter that aims to accurately emulate the key features of the detailed calorimeter response as simulated with Geant4, yet approximately ten times faster. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. A prototype of this new Fast Calorimeter Simulation is in development and its integration into the ATLAS simulation infrastructure is ongoing.

  8. The new ATLAS Fast Calorimeter Simulation

    Science.gov (United States)

    Schaarschmidt, J.; ATLAS Collaboration

    2017-10-01

    Current and future need for large scale simulated samples motivate the development of reliable fast simulation techniques. The new Fast Calorimeter Simulation is an improved parameterized response of single particles in the ATLAS calorimeter that aims to accurately emulate the key features of the detailed calorimeter response as simulated with Geant4, yet approximately ten times faster. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. A prototype of this new Fast Calorimeter Simulation is in development and its integration into the ATLAS simulation infrastructure is ongoing.

  9. Role of the CMS electromagnetic calorimeter in the measurement of the Higgs boson properties and search for new physics

    Science.gov (United States)

    Ferri, F.; CMS Collaboration

    2016-04-01

    The precise determination of the mass, the width and the couplings of the particle discovered in 2012 with a mass around 125 GeV is of capital importance to clarify the nature of such a particle, in particular to establish precisely if it is a Standard Model Higgs boson. In several new physics scenarios, in fact, the Higgs boson may behave differently with respect to the Standard Model one, or may not be unique, i.e. there can be more than one Higgs boson. In order to achieve the precision needed to discriminate between different models, the energy resolution, the scale uncertainty and the position resolution for electrons and photons are required to be as good as possible. The CMS scintillating lead-tungstate electromagnetic calorimeter (ECAL) was built as a precise tool with an exceptional energy resolution and a very good position resolution that improved over the years with the knowledge of the detector. Moreover, thanks to the fact that most of the lead-tungstate scintillation light is emitted in about 25 ns, the ECAL can be used to accurately determine the time of flight of photons. We present the current performance of the CMS ECAL, with a special emphasis on the impact on the measurement of the properties of the Higgs boson and on searches for new physics.

  10. Software studies of GLD calorimeter

    Indian Academy of Sciences (India)

    a reconstruction code in a GEANT4-based simulator, and evaluate the performance with single π0's. In the GLD, an option for the hadron calorimeter, the so-called digital calorime- ter, is still under consideration. It has a huge number of small active cells, signals from which are read out as 1-bit digital value (or at most few ...

  11. COE1 Calorimeter Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-15

    The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

  12. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  13. Fast Calorimeter Simulation in ATLAS

    CERN Document Server

    Schaarschmidt, Jana; The ATLAS collaboration

    2017-01-01

    Producing the very large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing CPU requirements when detailed detector simulations are not needed. During the LHC Run-1, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and it can be tuned to data more easily than GEANT4. It is 500 times faster than full simulation in the calorimeter system. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim makes use of mach...

  14. ELECTRONICS FOR CALORIMETERS AT LHC

    International Nuclear Information System (INIS)

    Radeka, V.

    2001-01-01

    Some principal design features of front-end electronics for calorimeters in experiments at the LHC will be highlighted. Some concerns arising in the transition from the research and development and design phase to the construction will be discussed. Future challenges will be indicated

  15. Barrel calorimeter of the CMD-3 detector

    Energy Technology Data Exchange (ETDEWEB)

    Shebalin, V. E., E-mail: V.E.Shebalin@inp.nsk.su; Anisenkov, A. V.; Aulchenko, V. M.; Bashtovoy, N. S. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation); Epifanov, D. A. [University of Tokyo, Department of Physics (Japan); Epshteyn, L. B.; Grebenuk, A. A.; Ignatov, F. V.; Erofeev, A. L.; Kovalenko, O. A.; Kozyrev, A. N.; Kuzmin, A. S.; Logashenko, I. B.; Mikhailov, K. Yu.; Razuvaev, G. P.; Ruban, A. A.; Shwartz, B. A.; Talyshev, A. A.; Titov, V. M.; Yudin, Yu. V. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2015-12-15

    The structure of the barrel calorimeter of the CMD-3 detector is presented in this work. The procedure of energy calibration of the calorimeter and the method of photon energy restoration are described. The distinctive feature of this barrel calorimeter is its combined structure; it is composed of two coaxial subsystems: a liquid xenon calorimeter and a crystalline CsI calorimeter. The calorimeter spatial resolution of the photon conversion point is about 2 mm, which corresponds to an angular resolution of ∼6 mrad. The energy resolution of the calorimeter is about 8% for photons with energy of 200 MeV and 4% for photons with energy of 1 GeV.

  16. An instant dose obtainable in situ calorimeter

    International Nuclear Information System (INIS)

    Kubo, H.; Mento, D.

    1984-01-01

    The development of a computer-linked water calorimeter is described. The advantages of this system are twofold: (i) instant dose determination is possible; and (ii) the calorimeter operation is much simpler than conventional null balance techniques. The entire calorimeter measurement procedure from the set-up to the dose determination for 10 runs was finished in approximately 2 1/2 h. A smaller calorimeter which could be kept in the treatment room for equilibrium, should permit further reduction of the time. The use of a smaller, portable computer would allow local data taking and analysis, eliminating the need for modems, phone lines and long cables. This would lead to a completely self-contained set-up at the treatment room. Although the technique is described for a polystyrene-water calorimeter, it should be equally applicable for a water calorimeter as well as a conventional isolated calorimeter. (author)

  17. Barrel calorimeter of the CMD-3 detector

    International Nuclear Information System (INIS)

    Shebalin, V. E.; Anisenkov, A. V.; Aulchenko, V. M.; Bashtovoy, N. S.; Epifanov, D. A.; Epshteyn, L. B.; Grebenuk, A. A.; Ignatov, F. V.; Erofeev, A. L.; Kovalenko, O. A.; Kozyrev, A. N.; Kuzmin, A. S.; Logashenko, I. B.; Mikhailov, K. Yu.; Razuvaev, G. P.; Ruban, A. A.; Shwartz, B. A.; Talyshev, A. A.; Titov, V. M.; Yudin, Yu. V.

    2015-01-01

    The structure of the barrel calorimeter of the CMD-3 detector is presented in this work. The procedure of energy calibration of the calorimeter and the method of photon energy restoration are described. The distinctive feature of this barrel calorimeter is its combined structure; it is composed of two coaxial subsystems: a liquid xenon calorimeter and a crystalline CsI calorimeter. The calorimeter spatial resolution of the photon conversion point is about 2 mm, which corresponds to an angular resolution of ∼6 mrad. The energy resolution of the calorimeter is about 8% for photons with energy of 200 MeV and 4% for photons with energy of 1 GeV

  18. The effects of tungstate on skin lesions caused by PPD in rats.

    Science.gov (United States)

    Lee, Sang-Hee; Cho, Hyun-Gug; Lee, Sang-Il

    2008-04-01

    P-phenylenediamine (PPD) has been used as one of the ingredients in hair dye. The purpose of this study is to investigate the skin toxicity of PPD application in a tungstate-induced xanthine oxidase (XO) deficient animal model. PPD (2.5% PPD in 2% NH4OH) was applied to rat skin (25 mg/16.5 cm2) five times every other day in rats fed a standard diet (SD) or a tungstate supplemented diet (TD). The skin structure in the SD and the TD group was intact, whereas XO activity was not detected in the TD group during experimental periods. Furthermore, there were no differences between the SD and the TD group in dermal reactive oxygen species (ROS) scavenging enzymes. In these experimental conditions, although XO activity was not detected in the applied PPD rats fed a tungstate supplemented diet (PTD) group, it showed more severe tissue damage compared with the applied PPD rats fed a standard diet (PSD) group. In addition, the PTD group showed higher increased rates of ROS scavenging enzyme activity and lipid peroxide (LPO) content, and decreased glutathione (GSH) content than in the PSD group. In conclusion, the increase of PPD dermal toxicity in tungstate-induced XO deficient animals may be due to excessive ROS via ROS imbalance during PPD skin application.

  19. Distorted octahedral coordination of tungstate in a subfamily of specific binding proteins

    NARCIS (Netherlands)

    Hollenstein, K.; Comellas-Bigler, M.; Bevers, L.E.; Feiters, M.C.; Meyer-Klaucke, W.; Hagedoorn, P.L.; Locher, K.P.

    2009-01-01

    Bacteria and archaea import molybdenum and tungsten from the environment in the form of the oxyanions molybdate (MoO4 2?) and tungstate (WO4 2?). These substrates are captured by an external, high-affinity binding protein, and delivered to ATP binding cassette transporters, which move them across

  20. Tungstate-Targeting of BKαβ1 Channels Tunes ERK Phosphorylation and Cell Proliferation in Human Vascular Smooth Muscle

    OpenAIRE

    López López, José Ramón; Fernández Mariño, Ana Isabel; Cidad, Pilar; Zafra, Delia; Nocito, Laura; Domínguez, Jorge; Oliván Viguera, Aida; Köhler, Ralf; Pérez García, María Teresa; Valverde, Miguel Ángel; Guinovart, Joan J.; Fernández Fernández, José Manuel

    2015-01-01

    Producción Científica Despite the substantial knowledge on the antidiabetic, antiobesity and antihypertensive actions of tungstate, information on its primary target/s is scarce. Tungstate activates both the ERK1/2 pathway and the vascular voltage- and Ca2+-dependent large-conductance BKαβ1 potassium channel, which modulates vascular smooth muscle cell (VSMC) proliferation and function, respectively. Here, we have assessed the possible involvement of BKαβ1 channels in the tungstate-induced...

  1. A general strategy toward the rational synthesis of metal tungstate nanostructures using plasma electrolytic oxidation method

    International Nuclear Information System (INIS)

    Jiang, Yanan; Liu, Baodan; Zhai, Zhaofeng; Liu, Xiaoyuan; Yang, Bing; Liu, Lusheng; Jiang, Xin

    2015-01-01

    Graphical abstract: A general strategy for the rational synthesis of tungstate nanostructure has been developed based on plasma electrolytic oxidation (PEO) technology (up). Using this method, ZnWO 4 and NiWO 4 nanostructures with controllable morphologies and superior crystallinity can be easily obtained (down), showing obvious advantage in comparison with conventional hydrothermal and sol–gel methods. - Highlights: • Plasma electrolyte oxidation (PEO) method has been used for the rational synthesis of tungstate nanostructures. • ZnWO 4 nanoplates have strong mechanical adhesion with porous TiO 2 film substrate. • The morphology and dimensional size of ZnWO 4 nanostructures can be selectively tailored by controlling the annealing temperature and growth time. • The PEO method can be widely applied to the growth of various metal oxides. - Abstract: A new method based on conventional plasma electrolytic oxidation (PEO) technology has been developed for the rational synthesis of metal tungstate nanostructures. Using this method, ZnWO 4 and NiWO 4 nanostructures with controllable morphologies (nanorods, nanosheets and microsheets) and superior crystallinity have been synthesized. It has been found that the morphology diversity of ZnWO 4 nanostructures can be selectively tailored through tuning the electrolyte concentration and annealing temperatures, showing obvious advantages in comparison to traditional hydrothermal and sol–gel methods. Precise microscopy analyses on the cross section of the PEO coating and ZnWO 4 nanostructures confirmed that the precursors initially precipitated in the PEO coating and its surface during plasma discharge process are responsible for the nucleation and subsequent growth of metal tungstate nanostructures by thermal annealing. The method developed in this work represents a general strategy toward the rational synthesis of metal oxide nanostructures and the formation mechanism of metal tungstate nanostructures fabricated by

  2. A general strategy toward the rational synthesis of metal tungstate nanostructures using plasma electrolytic oxidation method

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yanan; Liu, Baodan, E-mail: baodanliu@imr.ac.cn; Zhai, Zhaofeng; Liu, Xiaoyuan; Yang, Bing; Liu, Lusheng; Jiang, Xin, E-mail: xjiang@imr.ac.cn

    2015-11-30

    Graphical abstract: A general strategy for the rational synthesis of tungstate nanostructure has been developed based on plasma electrolytic oxidation (PEO) technology (up). Using this method, ZnWO{sub 4} and NiWO{sub 4} nanostructures with controllable morphologies and superior crystallinity can be easily obtained (down), showing obvious advantage in comparison with conventional hydrothermal and sol–gel methods. - Highlights: • Plasma electrolyte oxidation (PEO) method has been used for the rational synthesis of tungstate nanostructures. • ZnWO{sub 4} nanoplates have strong mechanical adhesion with porous TiO{sub 2} film substrate. • The morphology and dimensional size of ZnWO{sub 4} nanostructures can be selectively tailored by controlling the annealing temperature and growth time. • The PEO method can be widely applied to the growth of various metal oxides. - Abstract: A new method based on conventional plasma electrolytic oxidation (PEO) technology has been developed for the rational synthesis of metal tungstate nanostructures. Using this method, ZnWO{sub 4} and NiWO{sub 4} nanostructures with controllable morphologies (nanorods, nanosheets and microsheets) and superior crystallinity have been synthesized. It has been found that the morphology diversity of ZnWO{sub 4} nanostructures can be selectively tailored through tuning the electrolyte concentration and annealing temperatures, showing obvious advantages in comparison to traditional hydrothermal and sol–gel methods. Precise microscopy analyses on the cross section of the PEO coating and ZnWO{sub 4} nanostructures confirmed that the precursors initially precipitated in the PEO coating and its surface during plasma discharge process are responsible for the nucleation and subsequent growth of metal tungstate nanostructures by thermal annealing. The method developed in this work represents a general strategy toward the rational synthesis of metal oxide nanostructures and the formation mechanism of

  3. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    Dave Barney

    2010-01-01

    The operation of ECAL during the whole proton-proton period was very successful, with little down time. During this period we witnessed the first expected signs of radiation damage, both in the preshower detector, where we measured a small but clear increase in the current drawn by the silicon sensors (due to bulk damage) and in the endcap crystals, with the first evidence of a decreasing crystal transparency. The extent of the damage is in general as expected from simulations. However, a small fraction of the preshower sensors also show signs of unexpected surface damage. This is under investigation.
 The running period was very smooth overall but not without glitches. Among these occurrences we had a few high voltage problems in the endcaps, a low voltage connector at the preshower failed, a few unnoticed DCS alarms and our fair share of DAQ "out-of-sync". All problems were followed-up and mitigated where possible. Lessons learnt will be very useful for the long running period ahead of ...

  4. Tungsten transport protein A (WtpA) in Pyrococcus furiosus: the first member of a new class of tungstate and molybdate transporters.

    Science.gov (United States)

    Bevers, Loes E; Hagedoorn, Peter-Leon; Krijger, Gerard C; Hagen, Wilfred R

    2006-09-01

    A novel tungstate and molybdate binding protein has been discovered from the hyperthermophilic archaeon Pyrococcus furiosus. This tungstate transport protein A (WtpA) is part of a new ABC transporter system selective for tungstate and molybdate. WtpA has very low sequence similarity with the earlier-characterized transport proteins ModA for molybdate and TupA for tungstate. Its structural gene is present in the genome of numerous archaea and some bacteria. The identification of this new tungstate and molybdate binding protein clarifies the mechanism of tungstate and molybdate transport in organisms that lack the known uptake systems associated with the ModA and TupA proteins, like many archaea. The periplasmic protein of this ABC transporter, WtpA (PF0080), was cloned and expressed in Escherichia coli. Using isothermal titration calorimetry, WtpA was observed to bind tungstate (dissociation constant [K(D)] of 17 +/- 7 pM) and molybdate (K(D) of 11 +/- 5 nM) with a stoichiometry of 1.0 mol oxoanion per mole of protein. These low K(D) values indicate that WtpA has a higher affinity for tungstate than do ModA and TupA and an affinity for molybdate similar to that of ModA. A displacement titration of molybdate-saturated WtpA with tungstate showed that the tungstate effectively replaced the molybdate in the binding site of the protein.

  5. Design studies on the 4π γ-ray calorimeter for the ETF experiment at HIRFL-CSR

    Science.gov (United States)

    Yue, Ke; Xu, Hu-Shan; Sun, Zhi-Yu; Su, Guang-Hui; Wang, Jian-Song; Zheng, Chuan; Li, Song-Lin; Hu, Zheng-Guo; Chen, Rou-Fu; Xiao, Zhi-Gang; Hu, Qiang; Zhang, Xue-Ying; Yu, Yu-Hong; Chen, Jun-Ling

    2011-01-01

    A high detection efficiency calorimeter which is used to detect γ-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETF) experiments.

  6. Photoluminescence in solid solutions and thin films of tungstates CaWO{sub 4}-CdWO{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Taoufyq, A.; Mauroy, V.; Guinneton, F.; Valmalette, J-C. [University of Toulon, IM2NP, UMR CNRS 7334, La Garde, (France); Fiorido, T. [Aix Marseille University, IM2NP, UMR CNRS, 7334, Marseille, (France); Benlhachemi, A. [IBN ZOHR University, Faculty of sciences, Environment and Materials Laboratory, Agadir, (Morocco); Lyoussi, A. [CEA of Cadarache, DEN, Departement of reactors studies, experimental physics, Instrumentation Sensors and Dosimetry Laboratory, (France); Nolibe, G. [Cesigma society, signals and systems, La Garde, (France); Gavarri, J-R. [University of Toulon, IM2NP, UMR CNRS 7334, La Garde, (France)

    2015-07-01

    In this study, we present two types of studies on the luminescence properties under UV and X-ray excitations of solid solutions Ca{sub 1-x}Cd{sub x}WO{sub 4} and of thin layers of CaWO{sub 4} and CdWO{sub 4}. These tungstate based solid solutions are susceptible to be integrated into new radiation sensors, in order to be used in different fields of applications such as reactor measurements, safeguards, homeland security, nuclear nondestructive assays, LINAC emission radiation measurement. However these complex materials were rarely investigated in the literature. One first objective of our studies was to establish correlations between luminescence efficiency, chemical substitution and the degree of crystallization resulting from elaboration conditions. A second objective will be to determine the efficiency of luminescence properties of thin layers of these materials. In the present work, we focus our attention on the role of chemical substitution on photon emissions under UV and X-ray irradiations. The luminescence spectra of Ca{sub 1-x}Cd{sub x}WO{sub 4} polycrystalline materials have been investigated at room temperature as a function of composition (0≤x≤1). In addition, we present a preliminary study of the luminescence of CaWO{sub 4} and CdWO{sub 4} thin layers: oscillations observed in the case of X-ray excitations in the luminescence spectra are discussed. (authors)

  7. Laser micromachining of cadmium tungstate scintillator for high energy X-ray imaging

    Science.gov (United States)

    Richards, Sion Andreas

    Pulsed laser ablation has been investigated as a method for the creation of thick segmented scintillator arrays for high-energy X-ray radiography. Thick scintillators are needed to improve the X-ray absorption at high energies, while segmentation is required for spatial resolution. Monte-Carlo simulations predicted that reflections at the inter-segment walls were the greatest source of loss of scintillation photons. As a result of this, fine pitched arrays would be inefficient as the number of reflections would be significantly higher than in large pitch arrays. Nanosecond and femtosecond pulsed laser ablation was investigated as a method to segment cadmium tungstate (CdWO_4). The effect of laser parameters on the ablation mechanisms, laser induced material changes and debris produced were investigated using optical and electron microscopy, energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy for both types of lasers. It was determined that nanosecond ablation was unsuitable due to the large amount of cracking and a heat affected zone created during the ablation process. Femtosecond pulsed laser ablation was found to induce less damage. The optimised laser parameters for a 1028 nm laser was found to be a pulse energy of 54 μJ corresponding to a fluence of 5.3 J cm. -2 a pulse duration of 190 fs, a repetition rate of 78.3 kHz and a laser scan speed of 707 mm s. -1 achieving a normalised pulse overlap of 0.8. A serpentine scan pattern was found to minimise damage caused by anisotropic thermal expansion. Femtosecond pulsed ablation was also found to create a layer of tungsten and cadmium sub-oxides on the surface of the crystals. The CdWO_4 could be cleaned by immersing the CdWO_4 in ammonium hydroxide at 45°C for 15 minutes. However, XPS indicated that the ammonium hydroxide formed a thin layer of CdCO_3 and Cd(OH)_2 on the surface. Prototype arrays were shown to be able to resolve features as small as 0.5 mm using keV energy X-rays. The most

  8. ''Massless gaps'' for solenoid + calorimeter

    International Nuclear Information System (INIS)

    Marraffino, J.; Wu, W.; Beretvas, A.; Green, D.; Denisenko, K.; Para, A.

    1991-11-01

    The necessary existence of material in front of the first active element in a calorimeter will degrade the performance of that device. The question is by what factor. The follow up question is what can be done to minimize the damage. These questions are usually of primary importance for liquid argon calorimetry because of the necessity of containment dewars. However, the problem is universal. For example, the Solenoid Detector Collaboration, SDC, has proposed a superconducting coil which would be placed in front of the EM calorimeter. Although much effort has been made to minimize the depth of material in the coil, still the resolution and linearity must be optimized if the SDC goal of precision electromagnetic (EM) calorimetry is to be realized

  9. Electromagnetic calorimeter on liquid krypton

    International Nuclear Information System (INIS)

    Bazzotti, M.; Bianco, G.L.; Lanni, F.; Maggi, B.; Palombo, F.; Sala, A.

    1990-01-01

    This paper reports on use of noble condensed gases as calorimeter media that is attractive due to the possibility to get not only good energy resolution (like in NaI and CsI calorimeters) but better space resolution for photons. Longitudinal segmentation can provide information for particle identification by dE/dx and also e/π-separation based on longitudinal structure of the shower. The best material for this aim is of course liquid Zenon, but it is impossible to get the necessary amount of it in reasonable time. Therefore, the authors have stopped their choice on the next candidate-liquid Krypton (LKr). Its sufficient amount can be obtained before to the beginning of the experiment

  10. Next Generation CALICE Electromagnetic Calorimeter

    OpenAIRE

    Grondin, Denis; Jeans, Daniel

    2010-01-01

    This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different 'modules 0' (barrel and endcap) for a final detector, a technological ECAL prototype, called the EUDET module, is under design in order to have a close to full scale technological solution which could be used for the final detector, taking into account future industrialisation o...

  11. Next Generation CALICE Electromagnetic Calorimeter

    OpenAIRE

    Grondin, Denis; Jeans, Daniel

    2010-01-01

    This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different "modules 0" (barrel and endcap) for a final detector, a technological ECAL prototype, called the EUDET module, is under design in order to have a close to full scale technological solution which could be used for the final detector, taking into account future industrialisation o...

  12. The KLOE fiber electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Incagli, Marco

    1998-01-01

    The construction and equipment of the KLOE electromagnetic calorimeter has ended in March 1997. In parallel to the construction, all modules have been tested at the Cosmic Ray Test Stand (CRTS) facility, in Frascati National Laboratories (Rome). The construction technique, based on scintillating fibers alternated to very thin (0.5 mm) grooved lead planes, is described and the main results both from the CRTS and from a preliminary Test Beam with low energy electrons and muons are reported in this note

  13. The T.M. Calorimeter

    International Nuclear Information System (INIS)

    Mas, P.; Goer, J. de

    1970-01-01

    The T.M. calorimeter is the isothermal type. It consists only of a sample of graphite and a jacket of stainless steel filled with nitrogen. The chromel-alumel thermocouples which measure the temperature difference between the sample and the jacket also serve to suspend the sample. The jacket is kept at a constant temperature: i.e. that of the water in the swimming pool

  14. Electromagnetic Calorimeter for HADES Experiment

    Directory of Open Access Journals (Sweden)

    Rodríguez-Ramos P.

    2014-01-01

    Full Text Available Electromagnetic calorimeter (ECAL is being developed to complement dilepton spectrometer HADES. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 AGeV on the beam of future accelerator SIS100@FAIR. We will report results of the last beam test with quasi-monoenergetic photons carried out in MAMI facility at Johannes Gutenberg Universität Mainz.

  15. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Heelan, Louise; The ATLAS collaboration

    2015-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. It is also useful for identification and reconstruction of muons due to good signal to noise ratio. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5000 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1% using radioactive source, laser and charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of proton-proton collisions acquired in 2011 and 2012. Results on the calorimeter performance are presented, including the absolute energy scale, timing, noise and associated stabilities. The results demonstrate that the Tile Calorimeter has performed well within the design ...

  16. Measurements and simulations on position dependencies in the response of single PWO crystals and a prototype for the PANDA EMC

    International Nuclear Information System (INIS)

    Bremer, Daniel Andreas

    2013-01-01

    The PANDA experiment, which will be located at the future Facility for Antiproton and Ion Research, aims at the study of strong interaction within the charm sector via antiproton- proton collisions. An essential component of the PANDA detector to achieve the ambitious physics goals is the Electromagnetic Calorimeter (EMC). Reason for this is particularly its high detection efficiency for photons and electrons over a large dynamic range, since most of the expected physics channels are accompanied by secondary photons. The EMC is based on second generation lead tungstate scintillator crystals and thus features a very compact design and improved performance. To guarantee a homogeneous and precise energy and momentum response, an exact knowledge on the incident particle position is mandatory. In the scope of this work, non-uniformities in the light yield of single lead tungstate crystals with tapered geometry are investigated. This effect was studied with the SLitrani simulation package in comparison to a series of dedicated experimental setups. The so called precision setup allowed for a comparative measurement of the response to cosmic muons and low energetic photons. Furthermore, an analogous beam measurement was performed with 80 MeV protons. Both, simulation and experiments agree that, in case of the PANDA crystal geometry types, the obtained light yield increases quadratically with the distance of the location of the energy deposition inside the crystal to the photo sensor. A clear correlation of the observed amount of non-uniformity to the mean tapering angle of the individual crystal geometry type could be determined. Furthermore, no significant difference in non-uniformity was observed for the three different particle species. Therefore, the observed non-uniformities can be regarded as independent of the exact mechanism of the energy deposition. Hence, the main effect governing the obtained non-uniformities is the interplay of the focussing caused by the high

  17. Calorimeter detector consisting of a KMgF3 scintillator and parallel-plate avalanche chamber

    International Nuclear Information System (INIS)

    Buzulutskov, A.F.; Turchanovich, L.K.; Vasil'chenko, V.G.

    1989-01-01

    Scintillations of a KMgF 3 crystal have been detected in the parallel-plate avalanche chamber with a TEA gaseous photocathode, the scintillation signal is shown to be much higher than the direct ionization one. The characteristic properties of the calorimeters on the basis of such structure with electrical and optical readout are discussed. 10 refs.; 4 figs

  18. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    T. Tabarelli and D. Barney

    2011-01-01

    ECAL operations have been rather smooth during the past months, with few hardware problems, stable trigger rates etc. The downtimes attributed to ECAL have, however, increased recently, due to some crashes of the DAQ on the ECAL side. The frequency of problems has increased with luminosity and seems to occur more in the EE than in the EB. There are some indications suggesting these problems may be due to Single Event Upsets – radiation-induced modifications to the front-end electronics. Although this is not yet confirmed, measures are already being taken to reduce the time taken to recover from such problems in order to minimise downtime. No such problems have (yet) been seen in the ES. There has been enormous progress in improving the quality of the corrections required to take into account transparency variations of the ECAL crystals with radiation, through a detailed calibration of the response of the laser diagnostic line. The special LHC runs taken recently – 25-ns operation and h...

  19. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    D. Petyt

    2013-01-01

    In a break with tradition, the ECAL general meetings during the April CMS Week were devoted to a series of brainstorming sessions, focusing on a small number of hot-topic items. These included sessions on ECAL upgrades, analysis of 2012 detector performance and resolution, software development plans and a review of the ECAL calibration sequence. These sessions were well attended and extremely productive, and have helped to define and guide the direction of the ECAL effort planned for LS1. The area of ECAL upgrades has been particularly active over the past several months. A note summarising the test-beam performance of crystal matrices, irradiated with proton fluences representative of the end of Phase 1 LHC running, has been prepared and is being reviewed by ECAL. This important note provides data to tune and validate the simulation of ECAL ageing that has been implemented in CMSSW. This simulation is being used by the ECAL group and others to evaluate the physics performance of the ECAL at the end of Pha...

  20. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Document Server

    D. Barney

    2012-01-01

      There are no major concerns for the ECAL running and operation in 2012. The necessary ameliorations to the system were planned in December, and reviewed in a dedicated workshop at the end of January. Many interventions have taken place, mainly on the Trigger and DAQ side in order to bring all software into line with central developments (e.g. SLC5, XDAQ11 and use of SVN). In addition, steps are being taken to improve the recovery time of the system from “single event upsets (SEU)”, which are suspected to be the cause of some downtimes in 2011 (and, if so, would be more frequent in 2012 due to higher luminosities). A new blue laser, for crystal transparency monitoring, is currently being commissioned in Caltech and will be installed at P5 in March. We have optimised the ECAL zero-suppression settings applied online in preparation for the LHC running with high pile-up conditions. The algorithm to reduce the rate of anomalous signals  (“spikes”) fir...

  1. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL Barrel The integration of the last Supermodule was completed early July. The insertion of the second half Barrel (EB+) was performed in the second half of July. The Barrel ECAL (36 Supermodules comprising 61200 channels) is now complete, and its cabling campaign has just started. Each Supermodule has been tested after insertion. The number of dead or partially-dead channels amounts to only 28 (0.05% of the total), a performance showing the excellence of the quality control during the whole construction process. The Barrel Off-detector electronics is installed in the CMS Service cavern (with the exception of a few Trigger modules), ready to be connected to the Supermodules after cabling. The ECAL DAQ has been integrated with the CMS DAQ system: at the end of August one supermodule was included in a CMS global run, allowing us to record cosmic muons in both ECAL and DTs. ECAL Endcaps The Endcaps crystal production is proceeding at full speed, and the delivery rate (summing both producers) exceeds ...

  2. Upgrading ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Heath, Matthew Peter; The ATLAS collaboration

    2017-01-01

    Producing the very large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing CPU requirements when detailed detector simulations are not needed. During the LHC Run-1, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and it can be tuned to data more easily than Geant4. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim aims to overcome some limitations of the first version by improving the description of s...

  3. Structure design and enviromental test of BGO calorimeter for satellite DAMPE

    Science.gov (United States)

    Hu, Yiming; Feng, Changqing; Zhang, Yunlong; Chen, Dengyi; Chang, Jin

    2016-07-01

    The Dark Matter Particle Explorer, DAMPE, is a new designed satellite developed for the new Innovation 2020 program of Chinese Academy of Sciences. As the most important payload of China's first scientific satellite for detecting dark matter, the primary purposes of BGO calorimeter is to measure the energy of incident high energy electrons and gamma rays (5GeV-10TeV) and to identify hadron and electronics. BGO calorimeter also provides an important background discriminator by measuring the energy deposition due to the particle shower that produced by the e^{±}, γ and imaging their shower development profile. Structure design of BGO calorimeter is described in this paper. The new designed BGO calorimeter consists of 308 BGO crystals coupled with photomultiplier tubes on its two ends. The envelop size of the BGO calorimeter is 907.5mm×907.5mm×494.5mm,and the weight of which is 1051.4Kg. The most important purpose of mechanical design is how to package so heavy crystals into a detector as required arrangement and to make sure reliability and safety. This paper describes the results of vibration tests using the Flight Module of the BGO Calorimeter for the DAMPE satellite. During the vibration tests, no degradation of the mechanical assembly was observed. After random or sinusoidal vibrations, there was no significant changes of the frequency signatures observed during the modal surveys. The comparison of results of cosmic ray tests before and after the vibration shows no change in the performance of the BGO calorimeter.

  4. Reactive magnetron sputtering deposition of bismuth tungstate onto titania nanoparticles for enhancing visible light photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Ratova, Marina, E-mail: marina_ratova@hotmail.com [Surface Engineering Group, School of Engineering, Manchester Metropolitan University, Manchester, M1 5GD (United Kingdom); Kelly, Peter J.; West, Glen T. [Surface Engineering Group, School of Engineering, Manchester Metropolitan University, Manchester, M1 5GD (United Kingdom); Tosheva, Lubomira; Edge, Michele [School of Science and the Environment, Manchester Metropolitan University, Manchester M1 5GD (United Kingdom)

    2017-01-15

    Highlights: • Bismuth tungstate coatings were deposited by reactive magnetron sputtering. • Oscillating bowl was introduced to the system to enable coating of nanopartulates. • Deposition of Bi{sub 2}WO{sub 6} enhanced visible light activity of titania nanoparticles. • The best results were obtained for coating with Bi:W ratio of approximately 2:1. • Deposition of Bi{sub 2}WO{sub 6} onto TiO{sub 2} resulted in more efficient electron-hole separation. - Abstract: Titanium dioxide − bismuth tungstate composite materials were prepared by pulsed DC reactive magnetron sputtering of bismuth and tungsten metallic targets in argon/oxygen atmosphere onto anatase and rutile titania nanoparticles. The use of an oscillating bowl placed beneath the two magnetrons arranged in a co-planar closed field configuration enabled the deposition of bismuth tungstate onto loose powders, rather than a solid substrate. The atomic ratio of the bismuth/tungsten coatings was controlled by varying the power applied to each target. The effect of the bismuth tungstate coatings on the phase, optical and photocatalytic properties of titania was investigated by X-ray diffraction, energy-dispersive X-ray spectroscopy (EDX), Brunauer–Emmett–Teller (BET) surface area measurements, transmission electron microscopy (TEM), UV–vis diffuse reflectance spectroscopy and an acetone degradation test. The latter involved measurements of the rate of CO{sub 2} evolution under visible light irradiation of the photocatalysts, which indicated that the deposition of bismuth tungstate resulted in a significant enhancement of visible light activity, for both anatase and rutile titania particles. The best results were achieved for coatings with a bismuth to tungsten atomic ratio of 2:1. In addition, the mechanism by which the photocatalytic activity of the TiO{sub 2} nanoparticles was enhanced by compounding it with bismuth tungstate was studied by microwave cavity perturbation. The results of these

  5. Central hadron calorimeter of UA1

    International Nuclear Information System (INIS)

    Corden, M.J.; Dowell, J.D.; Edwards, M.J.

    1983-12-01

    An iron-scintillator sampling calorimeter is described, which measures hadronic energy in proton-antiproton interactions at the CERN 540 GeV SPS collider. Construction details are given of the instrumentation of the magnet pieces of the UA1 experiment and of the methods used to measure the calorimeter response and resolution. The system of lasers and quartz fibres, which allows long term monitoring of the calorimeter response, is also described. (author)

  6. Rugged calorimeter with a fast rise time

    International Nuclear Information System (INIS)

    McMurtry, W.M.; Dolce, S.R.

    1980-01-01

    An intrinsic 1-mil-thick gold foil calorimeter has been developed which rises to 95% of the energy deposited in less than 2 microseconds. This calorimeter is very rugged, and can withstand rough handling without damage. The time constant is long, in the millisecond range, because of its unique construction. Use of this calorimeter has produced 100% data recovery, and agreement with true deposition to less than 10%

  7. Central hadron calorimeter of UA1

    International Nuclear Information System (INIS)

    Corden, M.J.; Dowell, J.D.; Edwards, M.J.; Ellis, N.N.; Garvey, J.; Grant, D.; Homer, R.J.; Kenyon, I.R.; McMahon, T.J.; Schanz, G.; Sumorok, K.C.T.O.; Watkins, P.M.; Wilson, J.A.; Barnes, G.; Bowcock, T.J.V.; Eisenhandler, E.; Gibson, W.R.; Honma, A.K.; Kalmus, P.I.P.; Keeler, R.K.; Pritchard, T.W.; Salvi, G.A.P.; Thompson, G.; Arnison, G.T.J.; Astbury, A.; Cash, A.R.; Grayer, G.H.; Haynes, W.J.; Hill, D.L.; Moore, D.R.; Nandi, A.K.; Percival, M.D.; Roberts, J.H.C.; Scott, W.G.; Shah, T.P.; Stanhope, R.J.; White, D.E.A.

    1985-01-01

    An iron-scintillator sampling calorimeter is described, which measures hadronic energy in proton-antiproton interactions at the CERN 540 GeV SPS collider. Construction details are given of the instrumentation of the magnet pieces of the UA1 experiment and of the methods used to measure the calorimeter response and resolution. The system of lasers and quartz fibres, which allows long term monitoring of the calorimeter response, is also described. (orig.)

  8. Signal processing for liquid ionization calorimeters

    International Nuclear Information System (INIS)

    Cleland, W.E.; Stern, E.G.

    1992-01-01

    We present the results of a study of the effects of thermal and pileup noise in liquid ionization calorimeters operating in a high luminosity calorimeters operating in a high luminosity environment. The method of optimal filtering of multiply-sampled signals which may be used to improve the timing and amplitude resolution of calorimeter signals is described, and its implications for signal shaping functions are examined. The dependence of the time and amplitude resolution on the relative strength of the pileup and thermal noise, which varies with such parameters as luminosity, rapidity and calorimeter cell size, is examined

  9. Family reunion for the UA2 calorimeter

    CERN Multimedia

    Abha Eli Phoboo

    2015-01-01

    After many years in CERN’s Microcosm exhibition, the last surviving UA2 central calorimeter module has been moved to Hall 175, the technical development laboratory of the ATLAS Tile Hadronic Calorimeter (Tilecal). The UA2 and ATLAS calorimeters are cousins, as both were designed by Otto Gildemeister. Now side by side, the calorimeters illustrate the progress made in sampling organic scintillator calorimeters over the past 35 years.   The ATLAS Tile Calorimeter prototypes (left) and the UA2 central calorimeter (right) in Hall 175. (Image: Mario Campanelli/ATLAS.) From 1981 to 1990, the UA2 experiment was one of the two detectors on CERN’s flagship accelerator, the SPS. At the heart of the UA2 detector was the central calorimeter. It was made up of 24 slices – each weighing four tonnes – arranged like orange segments around the collision point. These calorimeter slices played a central role in the research carried out by UA2 for the discovery of W bosons...

  10. Secondary Emission Calorimeter Sensor Development

    Science.gov (United States)

    Winn, David R.; Onel, Yasar

    2012-12-01

    In a Secondary Emission electron(SEe) detector module, Secondary Emission electrons (SEe) are generated from an SE surface/cathode, when charged hadronic or electromagnetic particles, particularly shower particles, penetrate an SE sampling module placed between absorber materials (Fe, Cu, Pb, W etc) in calorimeters. The SE cathode is a thin (10-50 nm thick) film (simple metal-oxides, or other higher yield materials) on the surface of a metal plate, which serves as the entrance “window” to a compact vacuum vessel (metal or metal-ceramic); this SE film cathode is analogous to a photocathode, and the SEe are similar to p.e., which are then amplified by dynodes, also is in a PMT. SE sensor modules can make use of electrochemically etched/machined or laser-cut metal mesh dynode sheets, as large as ~30 cm square, to amplify the Secondary Emission Electrons (SEe), much like those that compact metal mesh or mesh dynode PMT's use to amplify p.e.'s. The construction requirements easier than a PMT, since the entire final assembly can be done in air; there are no critical controlled thin film depositions, cesiation or other oxygen-excluded processes or other required vacuum activation, and consequently bake-out can be a refractory temperatures; the module is sealed by normal vacuum techniques (welding or brazing or other high temperature joinings), with a simple final heated vacuum pump-out and tip-off. The modules envisioned are compact, high gain, high speed, exceptionally radiation damage resistant, rugged, and cost effective, and can be fabricated in arbitrary tileable shapes. The SE sensor module anodes can be segmented transversely to sizes appropriate to reconstruct electromagnetic cores with high precision. The GEANT4 and existing calorimeter data estimated calorimeter response performance is between 35-50 Secondary Emission electrons per GeV, in a 1 cm thick Cu absorber calorimeter, with a gain per SEe > 105 per SEe, and an e/pi<1.2. The calorimeter pulse width is

  11. The ATLAS Liquid Argon Calorimeters: integration, installation and commissioning

    International Nuclear Information System (INIS)

    Tikhonov, Yu.

    2008-01-01

    The ATLAS liquid argon calorimeter system consists of an electromagnetic barrel calorimeter and two end-caps with electromagnetic, hadronic and forward calorimeters positioned in three cryostats. Since May 2006 the LAr barrel calorimeter records regular calibration runs and takes cosmic muon data together with tile hadronic calorimeter in the ATLAS cavern. The cosmic runs with end-cap calorimeters started in April 2007. First results of these combined runs are presented

  12. Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Babich, Kanstantsin; Golutvin, Igor; Kalagin, Vladimir; Kamenev, Alexey; Konoplianikov, V; Kosarev, Ivan; Moissenz, K; Moissenz, P; Oleynik, Danila; Petrosian, A; Rogalev, Evgueni; Semenov, Roman; Sergeyev, S; Shmatov, Sergey; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Druzhkin, Dmitry; Ivanov, Alexander; Kudinov, Vladimir; Orlov, Alexandre; Smetannikov, Vladimir; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; de Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankoc, K; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grynev, B; Lyubynskiy, Vadym; Senchyshyn, Vitaliy; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; ODell, V; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gusum, K; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Wigmans, Richard; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2008-01-01

    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\\% to 5\\%.

  13. Simulation of light collection in calcium tungstate scintillation detectors

    Directory of Open Access Journals (Sweden)

    F. A. Danevich

    2015-12-01

    Full Text Available Due to high operational properties, the oxide scintillators are perspective for cryogenic scintillation experiments with aim of study rare nuclear processes. In order to optimize light yield and the energy resolution we performed calculations of the efficiency of light collection for different geometries of scintillation detector with CaWO4 crystal by Monte-Carlo method using Litrani, Geant4 and Zemax packages. The calculations were compared with experimental data in the same configurations, depending on the crystal shape, surface treatment, material and shape of the reflector and presence of optical contact. The best results were obtained with crystals shaped as the right prism with triangle base, with completely diffused surfaces, using mirror reflector shaped as a truncated cone. Simulations by using Litrani have shown the best agreement with experimental results.

  14. Nickel tungstate (NiWO4) nanoparticles/graphene composites: preparation and photoelectrochemical applications

    Science.gov (United States)

    Hosseini, Seyyedamirhossein; Farsi, Hossein; Moghiminia, Shokufeh; Zubkov, Tykhon; Lightcap, Ian V.; Riley, Andrew; Peters, Dennis G.; Li, Zhihai

    2018-05-01

    Nickel tungstate/graphene composite was synthesized in various compositions with application of a hydrothermal method. Chemical composition and morphology of each sample was studied via application of x-ray diffraction and transmission electron microscopy techniques. In the continuous, a photosystem was obtained by deposition of composite sample on a fluorine-doped tin oxide electrode with application of electrophoretic method. Electrode morphology was studied by employment of atomic force microscopy and SEM techniques. Eventually, light conversion properties and involved mechanism of fabricated photosystem was studied with application of the Mott–Schottky method. Our results confirmed that the optimum ratio between graphene and nickel tungstate is in the regime of 1:1.

  15. Distribution of tungstate in pregnant mice and effects on embryonic cells in vitro

    International Nuclear Information System (INIS)

    Wide, M.; Danielsson, B.R.G.; Dencker, L.

    1986-01-01

    Whole-body autoradiography and impulse counting experiments were used to study the distribution and retention of radioactivity in the pregnant mouse after administration of [ 185 W]tungstate. A rapid uptake was found in a number of tissues - skeleton, red pulp of the spleen, adrenal, liver, thyroid, pituitary, and ovary - and in the intestine and kidneys, through which it was rapidly excreted. 185 W was also readily transported from mother to fetus, although more in late than in early gestation. The largest metal retention was found in the maternal skeleton, kidneys, and spleen and in visceral yolk sac epithelium and the skeleton of the fetus. Furthermore, in vitro cytotoxicity experiments showed inhibition by tungstate of cartilage production in limb bud mesenchymal cultures at concentrations similar to those found in vivo

  16. High-power Yb- and Tm-doped double tungstate channel waveguide lasers

    NARCIS (Netherlands)

    van Dalfsen, Koop; Geskus, D.; Ay, F.; Worhoff, Kerstin; Aravazhi, S.; Pollnau, Markus

    The potassium double tungstates KGd(WO4)2, KY(WO4)2, and KLu(WO4)2 are excellent candidates for solid-state lasers because of their high refractive index of ~2.0-2.1, the large transition cross-sections of rare-earth (RE3+) ions doped into these hosts, and a reasonably large thermal conductivity of

  17. Mechanism of chlorination of some actinide and fission product phosphates and tungstates in chloride melts

    International Nuclear Information System (INIS)

    Kryukova, A.I.; Chernikov, A.A.; Skiba, O.V.; Kazantsev, G.N.

    1989-01-01

    Results of kinetic studies on the chlorination of crystalline phosphates and tungstates of uranium, cerium, zirconium, and plutonium by gaseous carbon tetrachloride in melts of alkali metal chlorides at 973-1073 degree K are analyzed. A mathematical model of the process is proposed. Analysis of regression models allowed solution of the problem by statistical evaluation of the effective factors and prediction within the limits of the factors studied of the optimal conditions for the process

  18. Performance of a dual readout calorimeter with a BGO electromagnetic section

    International Nuclear Information System (INIS)

    Gaudio, Gabriella

    2011-01-01

    The dual readout technique has been tested on a hybrid calorimeter. The electromagnetic section of this instrument consists of 100 BGO crystals and the hadronic section is made out scintillating and Cherenkov fibers embedded in a copper matrix (DREAM). The electromagnetic fraction of hadronic showers is evaluated on an event-by-event basis from the relative amounts of Cherenkov and scintillation lights produced in the shower development. The performance of such a calorimeter in terms of energy resolution is presented. Effects of side leakage on detector performance are also studied.

  19. Results of L3 BGO calorimeter calibration using an RFQ accelerator

    CERN Document Server

    Chaturvedi, U K; Gataullin, M; Gratta, Giorgio; Kirkby, D; Lu, W; Newman, H; Shvorob, A V; Tully, C; Zhu, R

    2000-01-01

    A novel calibration system based on a radiofrequency-quadrupole (RFQ) accelerator has been installed in the L3 experiment. Radiative capture of 1.85 MeV protons from the RFQ accelerator in a lithium target produces a flux of 17.6 MeV photons which are used to calibrate 11000 crystals of the L3 BGO calorimeter. In this paper we present results of the RFQ run taken in November 1997. A calibration precision of 0.6% was reached in the barrel of the L3 BGO calorimeter, and 0.7% in the BGO endcaps. (8 refs).

  20. Status of the ATLAS hadronic tile calorimeter

    International Nuclear Information System (INIS)

    Leitner, R.

    2005-01-01

    Short status of the Tile Calorimeter project is given. Major achievements in the mechanical construction of the detector modules, their instrumentation, cylinders assembly, as well as the principles of the detector front-end electronics, are described. The ideas of Tile Calorimeter module calibration are presented

  1. An overview of CMS central hadron calorimeter

    CERN Document Server

    Katta, S

    2002-01-01

    The central hadron calorimeter for CMS detector is a sampling calorimeter with active medium as scintillator plates interleaved with brass absorber plates. It covers the central pseudorapidity region (¿ eta ¿<3.0). The design and construction aspects are reported. The status of construction and assembly of various subdetectors of HCAL are presented. (5 refs).

  2. Cone calorimeter tests of wood composites

    Science.gov (United States)

    Robert H. White; Kuma Sumathipala

    2013-01-01

    The cone calorimeter is widely used for the determination of the heat release rate (HRR) of building products and other materials. As part of an effort to increase the availability of cone calorimeter data on wood products, the U.S. Forest Products Laboratory and the American Wood Council conducted this study on composite wood products in cooperation with the Composite...

  3. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  4. Assembly of the CMS hadronic calorimeter

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    The hadronic calorimeter is assembled on the end-cap of the CMS detector in the assembly hall. Hadronic calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  5. The Scintillator Tile Hadronic Calorimeter Prototype

    International Nuclear Information System (INIS)

    Rusinov, V.

    2006-01-01

    A high granularity scintillator hadronic calorimeter prototype is described. The calorimeter is based on a novel photodetector - Silicon Photo-Multiplier (SiPM). The main parameters of SiPM are discussed as well as readout cell construction and optimization. The experience with a small prototype production and testing is described. A new 8 k channel prototype is being manufactured now

  6. Several versions of forward gas ionization calorimeter

    International Nuclear Information System (INIS)

    Babintsev, V.V.; Kholodenko, A.G.; Rodnov, Yu.V.

    1994-01-01

    The properties of several versions of a gas ionization calorimeter are analyzed by means of the simulation with the GEANT code. The jet energy and coordinate resolutions are evaluated. Some versions of the forward calorimeter meet the ATLAS requirements. 13 refs., 15 figs., 7 tabs

  7. LHCb: Physics with the LHCb calorimeter

    CERN Multimedia

    Barsuk, S

    2007-01-01

    The LHCb calorimeter comprises the scintillator pad detector (SPD), preshower (PS), electromagnetic Shashlyk type (ECAL) and hadronichadronic Tile (HCAL) calorimeters, arranged in pseudo-projective geometry. All the four detectors follow the general principle of reading the light from scintillator tiles with wave length shifting fibers, and transporting the light towards photomultipliers (25 ns R/O).

  8. Calorimeter triggers for hard collisions

    International Nuclear Information System (INIS)

    Landshoff, P.V.; Polkinghorne, J.C.

    1978-01-01

    We discuss the use of a forward calorimeter to trigger on hard hadron-hadron collisions. We give a derivation in the covariant parton model of the Ochs-Stodolsky scaling law for single-hard-scattering processes, and investigate the conditions when instead a multiple- scattering mechanism might dominate. With a proton beam, this mechanism results in six transverse jets, with a total average multiplicity about twice that seen in ordinary events. We estimate that its cross section is likely to be experimentally accessible at avalues of the beam energy in the region of 100 GeV/c

  9. The STAR endcap electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Allgower, C.E.; Anderson, B.D.; Baldwin, A.R.; Balewski, J.; Belt-Tonjes, M.; Bland, L.C.; Brown, R.L.; Cadman, R.V.; Christie, W.; Cyliax, I.; Dunin, V.; Efimov, L.; Eppley, G.; Gagliardi, C.A.; Gagunashvili, N.; Hallman, T.; Hunt, W.; Jacobs, W.W.; Klyachko, A.; Krueger, K.; Kulikov, A.; Ogawa, A.; Panebratsev, Y.; Planinic, M.; Puskar-Pasewicz, J.; Rakness, G.; Razin, S.; Rogachevski, O.; Shimansky, S.; Solberg, K.A.; Sowinski, J.; Spinka, H.; Stephenson, E.J.; Tikhomirov, V.; Tokarev, M.; Tribble, R.E.; Underwood, D.; Vander Molen, A.M.; Vigdor, S.E.; Watson, J.W.; Westfall, G.; Wissink, S.W.; Yokosawa, A.; Yurevich, V.; Zhang, W.-M.; Zubarev, A.

    2003-01-01

    The STAR endcap electromagnetic calorimeter will provide full azimuthal coverage for high-p T photons, electrons and electromagnetically decaying mesons over the pseudorapidity range 1.086≤η≤2.00. It includes a scintillating-strip shower-maximum detector to provide π 0 /γ discrimination and preshower and postshower layers to aid in distinguishing between electrons and charged hadrons. The triggering capabilities and coverage it offers are crucial for much of the spin physics program to be carried out in polarized proton-proton collisions

  10. The STAR endcap electromagnetic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Allgower, C.E.; Anderson, B.D.; Baldwin, A.R.; Balewski, J.; Belt-Tonjes, M.; Bland, L.C.; Brown, R.L.; Cadman, R.V.; Christie, W.; Cyliax, I.; Dunin, V.; Efimov, L.; Eppley, G.; Gagliardi, C.A.; Gagunashvili, N.; Hallman, T.; Hunt, W.; Jacobs, W.W.; Klyachko, A.; Krueger, K.; Kulikov, A.; Ogawa, A.; Panebratsev, Y.; Planinic, M.; Puskar-Pasewicz, J.; Rakness, G.; Razin, S.; Rogachevski, O.; Shimansky, S.; Solberg, K.A.; Sowinski, J.; Spinka, H.; Stephenson, E.J.; Tikhomirov, V.; Tokarev, M.; Tribble, R.E.; Underwood, D.; Vander Molen, A.M.; Vigdor, S.E. E-mail: vigdor@iucf.indiana.edu; Watson, J.W.; Westfall, G.; Wissink, S.W.; Yokosawa, A.; Yurevich, V.; Zhang, W.-M.; Zubarev, A

    2003-03-01

    The STAR endcap electromagnetic calorimeter will provide full azimuthal coverage for high-p{sub T} photons, electrons and electromagnetically decaying mesons over the pseudorapidity range 1.086{<=}{eta}{<=}2.00. It includes a scintillating-strip shower-maximum detector to provide {pi}{sup 0}/{gamma} discrimination and preshower and postshower layers to aid in distinguishing between electrons and charged hadrons. The triggering capabilities and coverage it offers are crucial for much of the spin physics program to be carried out in polarized proton-proton collisions.

  11. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Cortes-Gonzalez, Arely; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two photomultiplier in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator based readout system. Combined information from all systems allows to monitor and equalise the calorimeter r...

  12. Upgrading the Fast Calorimeter Simulation in ATLAS

    CERN Document Server

    Schaarschmidt, Jana; The ATLAS collaboration

    2017-01-01

    The tremendous need for simulated samples now and even more so in the future, encourage the development of fast simulation techniques. The Fast Calorimeter Simulation is a faster though less accurate alternative to the full calorimeter simulation with Geant4. It is based on parametrizing the longitudunal and lateral energy deposits of single particles in the ATLAS calorimeter. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. The parametrizations are expanded to cover very high energies and very forward detector regions, to increase the applicability of the tool. A prototype of this upgraded Fast Calorimeter Simulation has been developed and first validations with single particles show substantial improvements over the previous version.

  13. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Marjanovic, Marija; The ATLAS collaboration

    2018-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibers to photo-multiplier tubes (PMTs), located in the outer part of the calorimeter. The readout is segmented into about 5000 cells, each one being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of the full readout chain during the data taking, a set of calibration sub-systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements, and an integrator based readout system. Combined information from all systems allows to monitor and to equalize the calorimeter response at each stage of the signal evolution, from scintillation light to digitization. Calibration runs are monitored from a data quality perspective and u...

  14. The large hadron collider beauty experiment calorimeters

    International Nuclear Information System (INIS)

    Martens, A.; LHCb Collaboration; Martens, A.

    2010-01-01

    The Large Hadron Collider beauty experiment (LHCb), one of the four largest experiments at the LHC at CERN, is dedicated to precision studies of CP violation and other rare effects, in particular in the b and c quark sectors. It aims at precisely measuring the Standard Model parameters and searching for effects inconsistent with this picture. The LHCb calorimeter system comprises a scintillating pad detector, a pre-shower (PS), electromagnetic (ECAL) and hadronic calorimeters, all of these employing the principle of transporting the light from scintillating layers with wavelength shifting fibers to photomultipliers. The fast response of the calorimeters ensures their key role in the LHCb trigger, which has to cope with the LHC collision rate of 40MHz. After discussing the design and expected performance of the LHCb calorimeter system, one addresses the time and energy calibration issues. The results obtained with the calorimeter system from the first LHC data will be shown.

  15. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00445232; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  16. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00445232; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises cesium radioactive sources, Laser and charge injection elements, and allows for monitoring and equalization of the calorimeter response at each stage of the signal production, ...

  17. Fabrication and properties of hot pressed bismuth tungstate

    International Nuclear Information System (INIS)

    Streicher, W.L.

    1978-01-01

    Bi 2 WO 6 is a synthetic polar material that is a possible candidate for energy conversion and detection systems. Previous research on this material has been concerned with crystal growth and sintering characteristics of polycrystalline compacts. This study involves itself with the fabrication of polycrystalline compacts by hot pressing techniques. Densities approaching theoretical crystal density were achieved by hot pressing at 850 0 C for one hour with pressures exceeding 35 MPa. Before hot pressing, the sintering range was determined by high temperature dilatometry of unfired Bi 2 WO 6 ceramics. Hot pressed discs were characterized by scanning electron microscopy, differential scanning calorimetry, and x-ray diffraction. Electrical properties were determined by dc resistivity, capacitance, and conductance measurements, ac poling, dc poling, and current-voltage measurements

  18. Fast calorimeter simulation in LHCb

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    Fast calorimeter simulation in LHCb In HEP experiments CPU resources required by MC simulations are constantly growing and become a very large fraction of the total computing power (greater than 75%). At the same time the pace of performance improvements from technology is slowing down, so the only solution is a more efficient use of resources. Efforts are ongoing in the LHC experiments to provide multiple options for simulating events in a faster way when higher statistics is needed. A key of the success for this strategy is the possibility of enabling fast simulation options in a common framework with minimal action by the final user. In this talk we will describe the solution adopted in Gauss, the LHCb simulation software framework, to selectively exclude particles from being simulated by the Geant4 toolkit and to insert the corresponding hits generated in a faster way. The approach, integrated within the Geant4 toolkit, has been applied to the LHCb calorimeter but it could also be used for other subdetec...

  19. Tungstate-induced color-pattern modifications of butterfly wings are independent of stress response and ecdysteroid effect.

    Science.gov (United States)

    Otaki, Joji M; Ogasawara, Tsuyoshi; Yamamoto, Haruhiko

    2005-06-01

    Systemic injections of sodium tungstate, a protein-tyrosine phosphatase (PTPase) inhibitor, to pupae immediately after pupation have been shown to efficiently produce characteristic color-pattern modifications on the wings of many species of butterflies. Here we demonstrated that the tungstate-induced modification pattern was entirely different from other chemically-induced ones in a species of nymphalid butterfly Junonia (Precis) orithya. In this species, the systemic injections of tungstate produced characteristic expansion of black area and shrinkage of white area together with the move of parafocal elements toward the wing base. Overall, pattern boundaries became obscure. In contrast, an entirely different modification pattern, overall darkening of wings, was observed by the injections of stress-inducing chemicals, thapsigargin, ionomycin, or geldanamycin, to pupae under the rearing conditions for the adult summer form. On the ventral wings, this darkening was due to an increase of the proportion of peppered dark scales, which was reminiscent of the natural fall form of this species. Under the same rearing conditions, the injections of ecdysteroid, which is a well-known hormone being responsible for the seasonal polyphenism of nymphalid butterflies, yielded overall expansion of orange area especially around eyespots. Taken together, we conclude that the tungstate-induced modifications are clearly distinguishable from those of stress response and ecdysteroid effect. This conclusion then suggests that the putative PTPase signaling pathway that is sensitive to tungstate uniquely contributes to the wing-wide color-pattern development in butterflies.

  20. Members of the ALICE collaboration greet the arrival of the experiment's first 500 lead tungstate crystals

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    L. to r: Vladislav Manko (Kurchatov Institute, Moscow, PHOS project leader), Arne Klovning (University of Bergen, PHOS technical coordinator), Vyacheslav Demanov (VNIIEF, Sarov), Bjorn Pommeresche (University of Bergen), Hans de Groot (CERN, ALICE resource coordinator), Dimitri Alexandrov (Kurchatov Institute, Moscow), Mikhail Ippolitov (Kurchatov Institute, Moscow), Yuri Vinogradov (VNIIEF, Sarov), Chris Fabjan (CERN, ALICE technical coordinator), Yuri Sibiriak (Kurchatov Institute, Moscow), Sergei Sadovsky (IHEP, Protvino), Jurgen Schukraft (CERN, ALICE spokesperson).

  1. A LYSO calorimeter for the SuperB factory

    Energy Technology Data Exchange (ETDEWEB)

    Eigen, G.; Zhou, Z. [University of Bergen, Institute of Physics (Norway); Chao, D.; Cheng, C.H.; Echenard, B.; Flood, K.T.; Hitlin, D.G.; Porter, F.C.; Zhu, R.Y. [California Institute of Technology (United States); De Nardo, G.; Sciacca, C. [Università di Napoli Federico II (Italy); INFN Sezione di Napoli (Italy); Bizzarri, M.; Cecchi, C. [Università degli Studi di Perugia (Italy); INFN Sezione di Perugia (Italy); Germani, S.; Lubrano, P.; Manoni, E.; Papi, A.; Scolieri, G. [INFN Sezione di Perugia (Italy); Rossi, A., E-mail: alessandro.rossi@pg.infn.it [Università degli Studi di Perugia (Italy); INFN Sezione di Perugia (Italy); Bocci, V. [INFN Sezione di Roma (Italy); and others

    2013-08-01

    The SuperB project is an asymmetric e{sup +}e{sup −} accelerator of 10{sup 36}cm{sup −2}s{sup −1} design luminosity, capable of collecting a data sample of 50–75ab{sup −1} in five years running. The SuperB electromagnetic calorimeter (EMC) provides energy and direction measurement of photons and electrons, and is used for identification of electrons versus other charged particles. In particular we present its design, geometry study and related simulations, as well as R and D on LYSO crystals and developments on readout electronics. A matrix of 25 crystals has been tested at the Beam Test Facility of Frascati (BTF) in May 2011 at energies between 200 MeV and 500 MeV. Results from this test are presented.

  2. Intercalibration of the ZEUS high resolution and backing calorimeters

    International Nuclear Information System (INIS)

    Abramowicz, H.; Czyrkowski, H.; Derlicki, A.; Krzyzanowski, M.; Kudla, I.; Kusmierz, W.; Nowak, R.J.; Pawlak, J.M.; Rajca, A.; Stopczynski, A.; Walczak, R.; Zarnecki, A.F.; Kowalski, T.Z.

    1991-07-01

    We have studied the combined performance of two calorimeters, the high resolution uranium-scintillator prototype of the ZEUS forward calorimeter (FCAL), followed by a prototype of the coarser ZEUS backing calorimeter (BAC), made out of thick iron plates interleaved with planes of aluminium proportional chambers. The test results, obtained in an exposure of the calorimeter system to a hadron test beam at the CERN-SPS, show that the backing calorimeter does fulfil its role of recognizing the energy leaking out of the FCAL calorimeter. The measurement of this energy is feasible, if an appropriate calibration of the BAC calorimeter is performed. (orig.)

  3. Intercalibration of the ZEUS high resolution and backing calorimeters

    International Nuclear Information System (INIS)

    Abramowicz, H.; Czyrkowski, H.; Derlicki, A.; Krzyzanowski, M.; Kudla, I.; Kusmierz, W.; Nowak, R.J.; Pawlak, J.M.; Rajca, A.; Stopczynski, A.; Walczak, R.; Zarnecki, A.F.; Kowalski, T.Z.

    1992-01-01

    We have studied the combined performance of two calorimeters, the high resolution uranium-scintillator prototype of the ZEUS forward calorimeter (FCAL), followed by a prototype of the coarser ZEUS backing calorimeter (BAC), made out of thick iron plates interleaved with planes of aluminium proportional chambers. The test results, obtained in an exposure of the calorimeter system to a hadron test beam at the CERN SPS, show that the backing calorimeter does fulfil its role of recognizing the energy leaking out of the FCAL calorimeter. The measurement of this energy is feasible, if an appropriate calibration of the BAC calorimeter is performed. (orig.)

  4. Large capacity water and air bath calorimeters

    International Nuclear Information System (INIS)

    James, S.J.; Kasperski, P.W.; Renz, D.P.; Wetzel, J.R.

    1993-01-01

    EG and G Mound Applied Technologies has developed an 11 in. x 17 in. sample size water bath and an 11 in. x 17 in. sample size air bath calorimeter which both function under servo control mode of operation. The water bath calorimeter has four air bath preconditioners to increase sample throughput and the air bath calorimeter has two air bath preconditioners. The large capacity calorimeters and preconditioners were unique to Mound design which brought about unique design challenges. Both large capacity systems calculate the optimum set temperature for each preconditioner which is available to the operator. Each system is controlled by a personal computer under DOS which allows the operator to download data to commercial software packages when the calorimeter is idle. Qualification testing yielded a one standard deviation of 0.6% for 0.2W to 3.0W Pu-238 heat standard range in the water bath calorimeter and a one standard deviation of 0.3% for the 6.0W to 20.0W Pu-238 heat standard range in the air bath calorimeter

  5. On halide derivatives of rare-earth metal(III) oxidomolybdates(VI) and -tungstates(VI)

    International Nuclear Information System (INIS)

    Schleid, Thomas; Hartenbach, Ingo

    2016-01-01

    Halide derivatives of rare-earth metal(III) oxidomolybdates(VI) have been investigated comprehensively over the last decade comprising the halogens fluorine, chlorine, and bromine. Iodide-containing compounds are so far unknown. The simple composition REXMoO 4 (RE=rare-earth element, X=halogen) is realized for X=F almost throughout the complete lanthanide series as well as for yttrium. While ytterbium and lutetium do not form any fluoride derivative, for lanthanum, only a fluoride-deprived compound with the formula La 3 FMo 4 O 16 is realized. Moreover, molybdenum-rich compounds with the formula REXMo 2 O 7 are also known for yttrium and the smaller lanthanoids. For X=Cl the composition REClMoO 4 is known for yttrium and the whole lanthanide series, although, four different structure types were identified. Almost the same holds for X=Br, however, only two different structure types are realized in this class of compounds. In the case of halide derivatives of rare-earth metal(III) oxidotungstates(VI) the composition REXWO 4 is found for chlorides and bromides only, so far. Due to the similar size of Mo 6+ and W 6+ cations, the structures found for the tungstates are basically the same as for the molybdates. With the larger lanthanides, the representatives for both chloride and bromide derivates exhibit similar structural motifs as seen in the molybdates, however, the crystal structure cannot be determined reliably. In case of the smaller lanthanoids, the chloride derivatives are isostructural with the respective molybdates, although the existence ranges differ slightly. The same is true for rare-earth metal(III) bromide oxidotungstates(VI).

  6. Non-compensation of the ATLAS barrel combined calorimeter prototype

    International Nuclear Information System (INIS)

    Kul'chitskij, Yu.A.; Kuz'min, M.V.

    1998-01-01

    The e / π ratio for the ATLAS Barrel Combined Calorimeter Prototype, composed from electromagnetic LArg calorimeter and hadronic Tile calorimeter was investigated. Response of Combined Calorimeter on pions and electrons in the energy region of 20-300 GeV was studied. Found e / h = 1.37 ± 0.01 ± 0.02 is in good agreement with the results from previous Combined Calorimeter tests but has more precisions

  7. First results from the SLD silicon calorimeters

    International Nuclear Information System (INIS)

    Berridge, S.C.; Bugg, W.M.; Kroeger, R.S.; Weidemann, A.W.; White, S.L.

    1992-07-01

    The small-angle calorimeters of the SLD were successfully operated during the recent SLC engineering run. The Luminosity Monitor and Small-Angle Tagger (LMSAT) covers the angular region between 28 and 68 milliradians from the beam axis, while the Medium-Angle Silicon Calorimeter (MASC) covers the 68--190 milliradian region. Both are silicon-tungsten sampling calorimeters; the LMSAT employs 23 layers of 0.86 X 0 sampling, while the MASC has 10 layers of 1.74 X 0 sampling. We present results from the first run of the SLC with the SLD on beamline

  8. Data acquisition system for LHCb calorimeter

    International Nuclear Information System (INIS)

    Dai Gang; Gong Guanghua; Shao Beibei

    2007-01-01

    LHCb Calorimeter system is mainly used to identify and measure the energy of the photon, electron, hadron produced by the collision of proton. TELL1 is a common data acquisition platform based on FPGA for LHCb experiment. It is used to adopt custom data acquisition and process method for every detector and provide the data standard for the CPU matrix. This paper provides a novel DAQ and data process model in VHDL for Calorimeter. According to this model. We have built an effective Calorimeter DAQ system, which would be used in LHCb Experiment. (authors)

  9. Calorimeter prediction based on multiple exponentials

    International Nuclear Information System (INIS)

    Smith, M.K.; Bracken, D.S.

    2002-01-01

    Calorimetry allows very precise measurements of nuclear material to be carried out, but it also requires relatively long measurement times to do so. The ability to accurately predict the equilibrium response of a calorimeter would significantly reduce the amount of time required for calorimetric assays. An algorithm has been developed that is effective at predicting the equilibrium response. This multi-exponential prediction algorithm is based on an iterative technique using commercial fitting routines that fit a constant plus a variable number of exponential terms to calorimeter data. Details of the implementation and the results of trials on a large number of calorimeter data sets will be presented

  10. ALICE Zero Degree Calorimeter (ZDC), General Pictures.

    CERN Multimedia

    2003-01-01

    The ZDC Calorimeter for spectator neutrons is made by 44 slabs of W-alloy; each slab has 44 grooves where quartz fibres are placed. The charged particles of the hadronic shower generated by the neutrons make Cerenkov light in the fibres and the light is collected by photomultipliers. Photos from 1 to 9 show the front-face of the calorimeter. Photo n. 10 shows the rear of the calorimeter where the fibres are divided in several groups to go to the different PMs.

  11. Calibration and performance of the CHORUS calorimeter

    International Nuclear Information System (INIS)

    Buontempo, S.; Capone, A.; Cocco, A.G.; De Pedis, D.; Di Capua, E.; Dore, U.; Ereditato, A.; Ferroni, M.; Fiorillo, G.; Loverre, P.F.; Luppi, C.; Macina, D.; Marchetti-Stasi, F.; Mazzoni, M.A.; Migliozzi, P.; Palladino, V.; Piredda, G.; Ricciardi, S.; Righini, P.P.; Saitta, B.; Santacesaria, R.; Strolin, P.; Zucchelli, P.

    1995-01-01

    A high resolution calorimeter has been built for CHORUS, an experiment which searches for ν μ →ν τ oscillation in the CERN neutrino beam. Aim of the calorimeter is to measure the energy and direction of hadronic showers produced in interactions of the neutrinos in a nuclear emulsion target and to track through-going muons. It is a longitudinally segmented sampling device made of lead and scintillating fibers or strips. This detector has been exposed to beams of pions and electrons of defined momentum for calibration. The method used for energy calibration and results on the calorimeter performance are reported. (orig.)

  12. CMS Calorimeter Trigger Phase I upgrade

    International Nuclear Information System (INIS)

    Klabbers, P; Gorski, T; Bachtis, M; Dasu, S; Fobes, R; Grothe, M; Ross, I; Smith, W H; Compton, K; Farmahini-Farahani, A; Gregerson, A; Seemuth, D; Schulte, M

    2012-01-01

    We present a design for the Phase-1 upgrade of the Compact Muon Solenoid (CMS) calorimeter trigger system composed of FPGAs and Multi-GBit/sec links that adhere to the μTCA crate Telecom standard. The upgrade calorimeter trigger will implement algorithms that create collections of isolated and non-isolated electromagnetic objects, isolated and non-isolated tau objects and jet objects. The algorithms are organized in several steps with progressive data reduction. These include a particle cluster finder that reconstructs overlapping clusters of 2x2 calorimeter towers and applies electron identification, a cluster overlap filter, particle isolation determination, jet reconstruction, particle separation and sorting.

  13. MARK II end cap calorimeter electronics

    International Nuclear Information System (INIS)

    Jared, R.C.; Haggerty, J.S.; Herrup, D.A.; Kirsten, F.A.; Lee, K.L.; Olson, S.R.; Wood, D.R.

    1985-10-01

    An end cap calorimeter system has been added to the MARK II detector in preparation for its use at the SLAC Linear Collider. The calorimeter uses 8744 rectangular proportional counter tubes. This paper describes the design features of the data acquisition electronics that has been installed on the calorimeter. The design and use of computer-based test stands for the amplification and signal-shaping components is also covered. A portion of the complete system has been tested in a beam at SLAC. In these initial tests, using only the calibration provided by the test stands, a resolution of 18%/√E was achieved

  14. Synthesis, characterization, and properties of reduced europium molybdates and tungstates

    Energy Technology Data Exchange (ETDEWEB)

    Abeysinghe, Dileka [Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 (United States); Gerke, Birgit [Institut für Anorganische und Analytische Chemie, Universität Münster , Corrensstrasse 30, Münster D-48149 (Germany); Morrison, Gregory; Hsieh, Chun H.; Smith, Mark D. [Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 (United States); Pöttgen, Rainer [Institut für Anorganische und Analytische Chemie, Universität Münster , Corrensstrasse 30, Münster D-48149 (Germany); Makris, Thomas M. [Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 (United States); Loye, Hans-Conrad zur, E-mail: zurloye@mailbox.sc.edu [Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208 (United States)

    2015-09-15

    Single crystals of K{sub 0.094}Eu{sub 0.906}MoO{sub 4}, K{sub 0.097}Eu{sub 0.903}WO{sub 4}, EuWO{sub 4}, and EuMoO{sub 4} were grown from molten chloride fluxes contained in vacuum-sealed fused silica and structurally characterized via single crystal X-ray diffraction. The in situ reduction of Eu{sup 3+} to Eu{sup 2+} was carried out using Mo, W, and Zn as metal reducing agents. All four compounds crystallize in the tetragonal space group of I4{sub 1}/a and adopt the scheelite (CaWO{sub 4}) structure type. The magnetic susceptibility of the reported compounds shows paramagnetic behavior down to 2 K. {sup 151}Eu Mössbauer spectroscopy was used to analyze the relative Eu{sup 2+} and Eu{sup 3+} content of the samples. All the compounds were further characterized by EPR, and UV-vis spectroscopy. - Graphical abstract: TOC Caption Two new reduced europium containing quaternary oxides, K{sub 0.094}Eu{sub 0.906}MoO{sub 4} and K{sub 0.097}Eu{sub 0.903}WO{sub 4}, and two previously reported ternary reduced oxides, EuWO{sub 4} and EuMoO{sub 4}, were synthesized via an in situ reduction of Eu{sup 3+} to Eu{sup 2+} under flux method using Mo, W, and Zn as metal reducing agents. {sup 151}Eu Mössbauer spectroscopy was used to analyze the relative Eu{sup 2+} and Eu{sup 3+} content of the samples. - Highlights: • K{sub 0.094}Eu{sub 0.906}MoO{sub 4}, K{sub 0.097}Eu{sub 0.903}WO{sub 4}, EuWO{sub 4}, and EuMoO{sub 4} have been synthesized and characterized. • The in situ reduction of Eu{sup 3+} to Eu{sup 2+} was carried out using Mo, W, and Zn as metal reducing agents. • Magnetic susceptibility data were collected. • {sup 151}Eu Mössbauer spectroscopy was used to analyze Eu{sup 2+} and Eu{sup 3+} content.

  15. The D0 calorimeter trigger

    International Nuclear Information System (INIS)

    Guida, J.

    1992-12-01

    The D0 calorimeter trigger system consists of many levels to make physics motivated trigger decisions. The Level-1 trigger uses hardware techniques to reduce the trigger rate from ∼ 100kHz to 200Hz. It forms sums of electromagnetic and hadronic energy, globally and in towers, along with finding the missing transverse energy. A minimum energy is set on these energy sums to pass the event. The Level-2 trigger is a set of software filters, operating in a parallel-processing microvax farm which further reduces the trigger rate to a few Hertz. These filters will reject events which lack electron candidates, jet candidates, or missing transverse energy in the event. The performance of these triggers during the early running of the D0 detector will also be discussed

  16. Tritium calorimeter setup and operation

    CERN Document Server

    Rodgers, D E

    2002-01-01

    The LBNL tritium calorimeter is a stable instrument capable of measuring tritium with a sensitivity of 25 Ci. Measurement times range from 8-hr to 7-days depending on the thermal conductivity and mass of the material being measured. The instrument allows accurate tritium measurements without requiring that the sample be opened and subsampled, thus reducing personnel exposure and radioactive waste generation. The sensitivity limit is primarily due to response shifts caused by temperature fluctuation in the water bath. The fluctuations are most likely a combination of insufficient insulation from ambient air and precision limitations in the temperature controller. The sensitivity could probably be reduced to below 5 Ci if the following improvements were made: (1) Extend the external insulation to cover the entire bath and increase the top insulation. (2) Improve the seal between the air space above the bath and the outside air to reduce evaporation. This will limit the response drift as the water level drops. (...

  17. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  18. CaloCube: a novel calorimeter for high-energy cosmic rays in space

    Directory of Open Access Journals (Sweden)

    Rappoldi A.

    2017-01-01

    Full Text Available CaloCube is an R&D project borne to develop a novel calorimeter design, optimized for high-energy cosmic ray measurements in space. A small prototype made of CsI(Tl elements has been built and tested on particle beams. A final version, made of 5×5×18 crystals and with dual readout (two photodiodes for each crystal, to cover the full required dynamic range, is under construction and will be tested at CERN SPS in Summer 2016. The dual readout compensation technique were developed and the feasibility to extract Čerenkov signals from CsI crystals verified.

  19. Are starburst galaxies proton calorimeters?

    Science.gov (United States)

    Wang, Xilu; Fields, Brian D.

    2018-03-01

    Several starburst galaxies have been observed in the GeV and TeV bands. In these dense environments, gamma-ray emission should be dominated by cosmic ray (CR) interactions with the interstellar medium (pcrpism → π0 → γγ). Indeed, starbursts may act as proton `calorimeters' where a substantial fraction of CR energy input is emitted in gamma-rays. Here, we build a one-zone, `thick-target' model implementing calorimetry and placing a firm upper bound on gamma-ray emission from CR interactions. The model assumes that CRs are accelerated by supernovae (SNe), and all suffer nuclear interactions rather than escape. Our model has only two free parameters: the CR proton acceleration energy per SN ɛcr, and the proton injection spectral index s. We calculate the pionic gamma-ray emission from 10 MeV to 10 TeV, and derive thick-target parameters for six galaxies with Fermi, H.E.S.S., and/or VERITAS data. Our model provides good fits for the M82 and NGC 253, and yields ɛcr and s values suggesting that SN CR acceleration is similar in starbursts and in our Galaxy. We find that these starbursts are indeed nearly if not fully proton calorimeters. For NGC 4945 and NGC 1068, the models are consistent with calorimetry but are less well-constrained due to the lack of TeV data. However, the Circinus galaxy and the ultra-luminous infrared galaxy Arp 220 exceed our pionic upper-limit; possible explanations are discussed.

  20. A highly segmented and compact liquid argon calorimeter for the LHC the TGT calorimeter

    CERN Document Server

    Berger, C; Geulig, H; Pierschel, G; Siedling, R; Tutas, J; Wlochal, M; Wotschack, J; Cheplakov, A P; Eremeev, R V; Feshchenko, A; Gavrishchuk, O P; Kazarinov, Yu M; Khrenov, Yu V; Kukhtin, V V; Ladygin, E; Obudovskij, V; Shalyugin, A N; Tolmachev, V T; Volodko, A G; Geweniger, C; Hanke, P; Kluge, E E; Krause, J; Putzer, A; Tittel, K; Wunsch, M; Bán, J; Bruncko, Dusan; Kriván, F; Kurca, T; Murín, P; Sándor, L; Spalek, J; Aderholz, Michael; Brettel, H; Dydak, Friedrich; Fent, J; Huber, J; Hajduk, L; Jakobs, K; Kiesling, C; Oberlack, H; Schacht, P; Stiegler, U; Bogolyubsky, M Yu; Chekulaev, S V; Kiryunin, A E; Kurchaninov, L L; Levitsky, M S; Maximov, V V; Minaenko, A A; Moiseev, A M; Semenov, P A; CERN. Geneva. Detector Research and Development Committee

    1992-01-01

    The development of a fast, highly granular and compact electromagnetic liquid argon calorimeter is proposed as an R&D project for an LHC calorimeter with full rapidity coverage. The proposed ``Thin Gap Turbine'' (TGT) calorimeter offers uniform energy response and constant energy resolution independent of the production angle of the impinging particle and of its impact position at the calorimeter. An important aspect of the project is the development of electronics for fast signal processing matched to the short charge collection time in the TGT read-out cell. The system aspects of the integration of a high degree of signal processing into the liquid argon would be investigated.

  1. What's new with the CMS hadron calorimeter

    CERN Document Server

    Hagopian, V

    2002-01-01

    The CMS Hadron Calorimeter is designed to measure hadron jets, single hadrons and single mu 's. The central barrel and the two end caps, made of brass and scintillators cover the ¿ eta ¿ range of 0.0 to 3.0. The two forward calorimeters made of iron and quartz fibers extend the ¿ eta ¿ range to 5.0. Scintillators are also placed outside of the magnet coil, within the muon system to measure the energy leakage from the central barrel. The construction of the calorimeter is about 50% complete. Several design changes were made to simplify the calorimeter and reduce the cost. The longitudinal segmentation of the central barrel and end caps was reduced by one unit. The quartz fiber diameter was doubled from 300 to 600 microns. Improvements were made to the hybrid photodetectors (HPD) and various other components. The special purpose ADC (QIE) and other electronics are in prototype stage. (3 refs).

  2. Upgrading the Atlas Tile Calorimeter Electronics

    CERN Document Server

    Popeneciu, G; The ATLAS collaboration

    2014-01-01

    Tile Calorimeter is the central hadronic calorimeter of the ATLAS experiment at LHC. Around 2024, after the upgrade of the LHC the peak luminosity will increase by a factor of 5 compared to the design value, thus requiring an upgrade of the Tile Calorimeter readout electronics. Except the photomultipliers tubes (PMTs), most of the on- and off-detector electronics will be replaced, with the aim of digitizing all PMT pulses at the front-end level and sending them with 10 Gb/s optical links to the back-end electronics. One demonstrator prototype module is planned to be inserted in Tile Calorimeter in 2015 that will include hybrid electronic components able to probe the new design.

  3. Modeling response variation for radiometric calorimeters

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1986-01-01

    Radiometric calorimeters are widely used in the DOE complex for accountability measurements of plutonium and tritium. Proper characterization of response variation for these instruments is, therefore, vital for accurate assessment of measurement control as well as for propagation of error calculations. This is not difficult for instruments used to measure items within a narrow range of power values; however, when a single instrument is used to measure items over a wide range of power values, improper estimates of uncertainty can result since traditional error models for radiometric calorimeters assume that uncertainty is not a function of sample power. This paper describes methods which can be used to accurately estimate random response variation for calorimeters used to measure items over a wide range of sample powers. The model is applicable to the two most common modes of calorimeter operation: heater replacement and servo control. 5 refs., 4 figs., 1 tab

  4. The Compact Muon Solenoid (CMS) hadron calorimeter

    International Nuclear Information System (INIS)

    Hagopian, Vasken

    1999-01-01

    The Hadron Calorimeter of the CMS detector for the CERN LHC accelerator is designed to measure hadron jets as well as single hadrons. It has six segments. The central barrel made of brass and scintillators covers the vertical bar η vertical bar range of about 0 to 1.3. Two End Caps, also made of brass and scintillators extends the vertical bar η vertical bar range to 3.0. Two Forward calorimeters made of iron and quartz fibers cover the range 3.0 to 5.0. Since the barrel portion of the calorimeter is only 6.5 interaction lengths, the outer barrel will sample, by scintillators, outside the magnet coil and cryostat. Progress has been made on all subsystems and prototypes have been built. We now have a better understanding of magnetic field effects on calorimeters

  5. CDF End Plug calorimeter Upgrade Project

    International Nuclear Information System (INIS)

    Apollinari, G.; de Barbaro, P.; Mishina, M.

    1994-01-01

    We report on the status of the CDF End Plug Upgrade Project. In this project, the CDF calorimeters in the end plug and the forward regions will be replaced by a single scintillator based calorimeter. After an extensive R ampersand D effort on the tile/fiber calorimetry, we have now advanced to a construction phase. We review the results of the R ampersand D leading to the final design of the calorimeters and the development of tooling devised for this project. The quality control program of the production of the electromagnetic and hadronic calorimeters is described. A shower maximum detector for the measurement of the shower centroid and the shower profile of electrons, γ and π 0 has been designed. Its performance requirements, R ampersand D results and mechanical design are discussed

  6. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00304670; The ATLAS collaboration

    2016-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted to photomultiplier tubes (PMTs). Signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. Results on the calorimeter operation and performance are presented, including the calibration, stability, absolute energy scale, uniformity and time resolution. These results show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  7. Performance of the ATLAS Zero Degree Calorimeter

    CERN Document Server

    Leite, M; The ATLAS collaboration

    2013-01-01

    The ATLAS Zero Degree Calorimeter (ZDC) at the Large Hadron Collider (LHC) is a set of two sampling calorimeters modules symmetrically located at 140m from the ATLAS interaction point. The ZDC covers a pseudorapidity range of |eta| > 8.3 and it is both longitudinally and transversely segmented, thus providing energy and position information of the incident particles. The ZDC is installed between the two LHC beam pipes, in a configuration such that only the neutral particles produced at the interaction region can reach this calorimeter. The ZDC uses Tungsten plates as absorber material and rods made of quartz interspersed in the absorber as active media. The energetic charged particles crossing the quartz rods produces Cherenkov light which is then detected by photomultipliers and sent to the front end electronics for processing, in a total of 120 individual electronic channels. The Tungsten plates and quartz rods are arranged in a way to segment the calorimeters in 4 longitudinal sections. The first section (...

  8. Dual-readout calorimetry with scintillating crystals

    International Nuclear Information System (INIS)

    Pinci, D

    2009-01-01

    The dual-readout approach, which allows an event-by-event measurement of the electromagnetic shower fraction, was originally demonstrated with the DREAM sampling calorimeter. This approach can be extended to homogeneous detectors like crystals if Cherenkov and scintillation light can be separated. In this paper we present several methods we developed for distinguishing the two components in PWO and BGO based calorimeters and the results obtained.

  9. Investigation into interaction of mixture of zinc and neodymium nitrates with sodium tungstates in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rozantsev, G M; Krivobok, V I [Donetskij Gosudarstvennyj Univ. (Ukrainian SSR)

    1978-09-01

    The methods of residual concentrations, pH-potentiometry, and conductometry have been used for studying interaction between the mixture of zinc and neodymium nitrates with sodium tungstate in aqueous solutions. It has been established that independent of the ratio between the components the reaction product is a mixture of simultaneously precipitated zinc and neodymium orthotungstates. Thermal treatment of such mixtures at 650-700 deg C for 40 h and subsequent hardening yields solid solution of the structure ..cap alpha..-Eu/sub 2/(WO/sub 4/)/sub 3/ within the concentration range 85-100 mol % of Nd/sub 2/(WO/sub 4/)/sub 3/.

  10. Sampling calorimeters in high energy physics

    International Nuclear Information System (INIS)

    Gordon, H.A.; Smith, S.D.

    1980-01-01

    Attention is given to sampling calorimeters - those instruments in which part of the shower is sampled in an active medium sandwiched between absorbing layers. A very cursory overview is presented of some fundamental aspects of sampling calorimeters. First the properties of shower development are described for both the electromagnetic and hadronic cases. Then examples of various readout schemes are discussed. Finally, some currently promising new ideas in calorimetry are described

  11. Heavy ion studies with CMS HF calorimeter

    International Nuclear Information System (INIS)

    Damgov, I.; Genchev, V.; Kolosov, V.A.; Lokhtin, I.P.; Petrushanko, S.V.; Sarycheva, L.I.; Teplov, S.Yu.; Shmatov, S.V.; Zarubin, P.I.

    2001-01-01

    The capability of the very forward (HF) calorimeter of the CMS detector at LHC to be applied to specific studies with heavy ion beams is discussed. The simulated responses of the HF calorimeter to nucleus-nucleus collisions are used for the analysis of different problems: reconstruction of the total energy flow in the forward rapidity region, accuracy of determination of the impact parameter of collision, study of fluctuations of the hadronic-to-electromagnetic energy ratio, fast inelastic event selection

  12. The new RD52 (DREAM) fiber calorimeter

    International Nuclear Information System (INIS)

    Wigmans, Richard

    2012-01-01

    Simultaneous detection of the Cerenkov light and scintillation light produced in hadron showers makes it possible to measure the electromagnetic shower fraction event by event and thus eliminate the detrimental effects of fluctuations in this fraction on the performance of calorimeters. In the RD52 (DREAM) project, the possibilities of this dual-readout calorimetry are investigated and optimized. In this talk, the first test results of prototype modules for the new full-scale fiber calorimeter are presented.

  13. The performance of the ZEUS calorimeter

    International Nuclear Information System (INIS)

    Crittenden, J.A.

    1994-12-01

    The ZEUS experiment has now completed its third year of operation at the electron-proton collider HERA. The uranium/scintillator sampling calorimeter surrounding the inner tracking detectors has proven an essential component for the online triggering algorithms, for offline event-type identification, for kinematic variable reconstruction, and for a ariety of physics analyses. This paper summarizes the experimental context, the operating characteristics, the calibration techniques, and the performance of the calorimeter during its first three years of operation. (orig.)

  14. The electromagnetic calorimeter of the NOMAD experiment

    Energy Technology Data Exchange (ETDEWEB)

    Autiero, D; Baldo-Ceolin, M; Barichello, G; Bianchi-Bonaiti, V; Bobisut, F; Cardini, A; Cattaneo, P W; Cavasinni, V; Conta, C; Del Prete, T; De Santo, A; Di Lella, L; Ferrari, R; Flaminio, V; Fraternali, M; Gibin, D; Gninenko, S N; Guglielmi, A; Iacopini, E; Kovzelev, A V; La Rotonda, L; Lanza, A; Laveder, M; Lazzeroni, C; Livan, M; Mezzetto, M; Orestano, D; Pastore, F; Pennacchio, E; Petti, R; Polesello, G; Renzoni, G; Rimoldi, A; Roda, C; Sconza, A; Sobczynski, C; Valdata-Nappi, M; Vascon, M; Vercesi, V; Visentin, L; Volkov, S A [Pisa Univ. (Italy). Dipt. di Fisica; [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); [Dipartimento di Fisica, Universita di Padova and INFN, Sezione di Padova, Padova (Italy); [Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia and INFN, Sezione di Pavia, Pavia (Italy); [CERN, Geneva (Switzerland); [Dipartimento di Fisica, Universita di Firenze and INFN, Sezione di Firenze, Firenze (Italy); [Institute of Nuclear Research, INR, Moscow (Russian Federation); [Dipartimento di Fisica, Universita della Calabria and INFN, Gruppo Collegato di Cosenza, Cosenza (Italy)

    1996-05-01

    A description is given of the NOMAD electromagnetic calorimeter, consisting of 875 lead-glass counters read out by two-stage photomultipliers and a low noise electronic chain. The detector operates in a 0.4 T magnetic field transverse to the counter axis. The paper discusses the design criteria, the lead-glass characteristics, the properties of the read out chain and provides a summary of the calorimeter performance. (orig.).

  15. Radiation-Hard Quartz Cerenkov Calorimeters

    International Nuclear Information System (INIS)

    Akgun, U.; Onel, Y.

    2006-01-01

    New generation hadron colliders are going to reach unprecedented energies and radiation levels. Quartz has been identified as a radiation-hard material that can be used for Cerenkov calorimeters of the future experiments. We report from the radiation hardness tests performed on quartz fibers, as well as the characteristics of the quartz fiber and plate Cerenkov calorimeters that have been built, designed, and proposed for the CMS experiment

  16. The high resolution spaghetti hadron calorimeter

    International Nuclear Information System (INIS)

    Jenni, P.; Sonderegger, P.; Paar, H.P.; Wigmans, R.

    1987-01-01

    It is proposed to build a prototype for a hadron calorimeter with scintillating plastic fibres as active material. The absorber material is lead. Provided that these components are used in the appropriate volume ratio, excellent performance may be expected, e.g. an energy resolution of 30%/√E for jet detection. The proposed design offers additional advantages compared to the classical sandwich calorimeter structures in terms of granularity, hermiticity, uniformity, compactness, readout, radiation resistivity, stability and calibration. 22 refs.; 7 figs

  17. A neutron calorimeter as a fusion diagnostic

    International Nuclear Information System (INIS)

    Proctor, A.E.; Harker, Y.D.; Neischmidt, E.B.

    1986-01-01

    A calorimeter is described which is applicable as a fusion neutron diagnostic. The advantages of the device are discussed, including: low sensitivity to thermal neutrons, no heat loss to surroundings, large dynamic range, small mass resulting in fair time resolution, and small physical size. The heat generation is provided by neutron induced fissions in a foil of 238 U and a calorimeter is isothermal. The effects, advantages and disadvantages of other target materials are discussed. Also discussed are time resolution and calibration

  18. The NA48 liquid krypton calorimeter

    CERN Document Server

    Gorini, B

    1997-01-01

    The NA48 collaboration goal is to measure the CP violation parameter Re(ɛl/ɛ) at the level of 2 × 10−4. The neutral Kaon decays will be reconstructed by an electromagnetic liquid Krypton calorimeter with fine granularity and a volume almost totally sensible, to obtain excellent position and energy resolution, as well as time resolution. A description of the detector, results from tests of a prototype and the status of the final calorimeter are reported.

  19. The electromagnetic calorimeter of the NOMAD experiment

    International Nuclear Information System (INIS)

    Autiero, D.; Baldo-Ceolin, M.; Barichello, G.; Bianchi-Bonaiti, V.; Bobisut, F.; Cardini, A.; Cattaneo, P.W.; Cavasinni, V.; Conta, C.; Del Prete, T.; De Santo, A.; Di Lella, L.; Ferrari, R.; Flaminio, V.; Fraternali, M.; Gibin, D.; Gninenko, S.N.; Guglielmi, A.; Iacopini, E.; Kovzelev, A.V.; La Rotonda, L.; Lanza, A.; Laveder, M.; Lazzeroni, C.; Livan, M.; Mezzetto, M.; Orestano, D.; Pastore, F.; Pennacchio, E.; Petti, R.; Polesello, G.; Renzoni, G.; Rimoldi, A.; Roda, C.; Sconza, A.; Sobczynski, C.; Valdata-Nappi, M.; Vascon, M.; Vercesi, V.; Visentin, L.; Volkov, S.A.

    1996-01-01

    A description is given of the NOMAD electromagnetic calorimeter, consisting of 875 lead-glass counters read out by two-stage photomultipliers and a low noise electronic chain. The detector operates in a 0.4 T magnetic field transverse to the counter axis. The paper discusses the design criteria, the lead-glass characteristics, the properties of the read out chain and provides a summary of the calorimeter performance. (orig.)

  20. ATLAS Tile Calorimeter calibration and monitoring systems

    Science.gov (United States)

    Cortés-González, Arely

    2018-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. Neutral particles may also produce a signal after interacting with the material and producing charged particles. The readout is segmented into about 5000 cells, each of them being read out by two photomultipliers in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. This comprises Cesium radioactive sources, Laser, charge injection elements and an integrator based readout system. Information from all systems allows to monitor and equalise the calorimeter response at each stage of the signal production, from scintillation light to digitisation. Calibration runs are monitored from a data quality perspective and used as a cross-check for physics runs. The data quality efficiency achieved during 2016 was 98.9%. These calibration and stability of the calorimeter reported here show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  1. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Van Daalen, Tal Roelof; The ATLAS collaboration

    2018-01-01

    Performance of the ATLAS hadronic Tile calorimeter The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for the reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized every 25 ns by sampling the signal. About 10000 channels of the front-end electronics measure the signals of the calorimeter with energies ranging from ~30 MeV to ~2 TeV. Each step of the signal reconstruction from scintillation light to the digital pulse reconstruction is monitored and calibrated. The performance of the calorimeter has been studied in-situ employing cosmic ray muons and a large sample of proton-proton collisions acquired during the operations...

  2. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  3. ATLAS: last few metresfor the Calorimeter

    CERN Multimedia

    2005-01-01

    On Friday 4th November, the ATLAS Barrel Calorimeter was moved from its assembly point at the side of the ATLAS cavern to the centre of the toroidal magnet system. The detector was finally aligned, to the precision of within a millimetre, on Wednesday 9th November. The ATLAS installation team, led by Tommi Nyman, after having positioned the Barrel Calorimeter in its final location in the ATLAS experimental cavern UX15. The Barrel Calorimeter which will absorb and measure the energy of photons, electrons and hadrons at the core of the ATLAS detector is 8.6 meters in diameter, 6.8 meters long, and weighs over 1600 Tonnes. It consists of two concentric cylindrical detector elements. The innermost comprises aluminium pressure vessels containing the liquid argon electromagnetic calorimeter and the solenoid magnet. The outermost is an assembly of 64 hadron tile calorimeter sectors. Assembled 18 meters away from its final position, the Barrel Calorimeter was relocated with the help of a railway, which allows the ...

  4. Last Few Metres for the Barrel Calorimeter

    CERN Multimedia

    Nyman, T.

    On Friday 4th November, the ATLAS Barrel Calorimeter was moved from its assembly point at the side of the ATLAS cavern to the centre of the toroidal magnet system. The detector was finally aligned, to the precision of within a millimetre, on Wednesday 9th November. The ATLAS installation team, led by Tommi Nyman, after having positioned the Barrel Calorimeter in its final location in the ATLAS experimental cavern UX15. The Barrel Calorimeter which will absorb and measure the energy of photons, electrons and hadrons at the core of the ATLAS detector is 8.6 meters in diameter, 6.8 meters long, and weighs over 1600 Tonnes. It consists of two concentric cylindrical detector elements. The innermost comprises aluminium pressure vessels containing the liquid argon electromagnetic calorimeter and the solenoid magnet. The outermost is an assembly of 64 hadron tile calorimeter sectors. Assembled 18 meters away from its final position, the Barrel Calorimeter was relocated with the help of a railway, which allows ...

  5. Sampling calorimeters in high energy physics

    International Nuclear Information System (INIS)

    Gordon, H.A.; Smith, S.D.

    1981-01-01

    At our current understanding of elementary particle physics, the fundamental constituents are the photon, quarks, gluons and leptons with a few highly forecasted heavy bosons. Calorimeters are essential for detecting all of these particles. Quarks and gluons fragment into many particles - at high energies, so many particles that one may not want to measure each one separately. This group of both charged and neutral particles can only be measured by calorimeters. The energy of an electron needs to be measured by a calorimeter and muon identification is enhanced by the recognition of a minimum ionizing particle passing through the calorimeter. Sampling calorimeters - those instruments in which part of the shower is sampled in an active medium sandwiched between absorbing layers - are reviewed. What follows is a very cursory overview of some fundamental aspects of sampling calorimeters. First, the properties of shower development are described for both the electromagnetic and hadronic cases. Then, examples of various readout schemes are discussed. Finally, some currently promising new ideas in calorimetry are described. 21 references

  6. Performance of the ATLAS Tile Calorimeter

    Science.gov (United States)

    Hrynevich, A.

    2017-06-01

    The Tile Calorimeter (TileCal) is the central scintillator-steel sampling hadronic calorimeter of the ATLAS experiment at the LHC . Jointly with other calorimeters it is designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV . Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions. The response of high momentum isolated muons is used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response and its modelling by the Monte Carlo simulations. The calorimeter time resolution is studied with multijet events. Results on the calorimeter operation and performance are presented, including the calibration, stability, absolute energy scale, uniformity and time resolution. These results show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  7. Manufacturing of a graphite calorimeter at Yazd Radiation Processing Center

    International Nuclear Information System (INIS)

    Ziaie, F.

    2004-01-01

    In this work, a few quasi-adiabatic graphite calorimeters of different dimensions are described. The calorimeters have been manufactured by ourselves and studied for accurate absorbed dose measurements in 10 MeV electron beam. In order to prove the accuracy and reliability of dose measurements with the use of self designed graphite calorimeters (SCD), an inter comparison study was performed on these calorimeters and Risoe graphite calorimeters (SC,standard calorimeter) at different doses by using Rhodothron accelerator. The comparison shows conclusively of the optimal size, the results agreeing with those obtained with the Sc within 1%. (author)

  8. Background suppression by pulse shape discrimination in the CALIFA calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Heiss, Benjamin; Gernhaeuser, Roman; Klenze, Philipp; Remmels, Patrick; Winkel, Max [Technische Universtaet Muenchen (Germany); Collaboration: R3B-Collaboration

    2016-07-01

    The 4π-calorimeter CALIFA is one of the major detectors of the R{sup 3}B-experiment at the upcoming Facility for Antiproton and Ion Research (FAIR) in Darmstadt. This calorimeter with 2464 CsI(Tl) crystals and 96 Phoswich detectors (LaBr{sub 3}(Ce) and LaCl{sub 3}(Ce)) plays a major role in the realization of kinematically complete measurements. General demands on CALIFA are a high efficiency, good energy resolution of about 5 % at 1 MeV γ energies and a large dynamic range, allowing a simultaneous measurement of γ-rays at E > 100 keV and scattered protons up to E < 700 MeV. Due to the very high energies of the light charged particles at the relativistic beam energies, especially in the forward direction of CALIFA, a significant fraction triggers nuclear reactions in the detector material. This talk presents the methods of the background suppression by pulse shape discrimination based on an experiment with protons at kinetic energies up to E = 480 MeV at the TRIUMF Laboratory in Vancouver, Canada.

  9. Double aberration-corrected TEM/STEM of tungstated zirconia nanocatalysts for the synthesis of paracetamol

    International Nuclear Information System (INIS)

    Yoshida, K; Boyes, E D; Gai, P L; Shiju, N R; Brown, D R

    2010-01-01

    We report highly active tungstated zirconia nanocatalysts for the synthesis of paracetamol by Beckmann rearrangement of 4-hydroxyacetophenone oxime. Double aberration-corrected (2AC)-TEM/STEM studies were performed in a JEOL 2200FS FEG TEM/STEM at the 1 Angstrom (1 A = 0.1 nanometer) level. Observations at close to zero defocus were carried out using the AC-TEM as well as AC-STEM including high angle annular dark field (HAADF) imaging, from the same areas of the catalyst crystallites. The studies from the same areas have revealed the location and the nanostructure of the polytungstate species (clusters) and the nanograins of zirconia. The AC (S)TEM was crucial to observe the nanostructure and location of polytungstate clusters on the zirconia grains. Polytungstate clusters as small as 0.5 nm have been identified using the HAADF-STEM. The nanostructures of the catalyst and the W surface density have been correlated with paracetamol reaction studies. The results demonstrate the nature of active sites and high activity of the tungstated zirconia nanocatalyst, which is an environmentally clean alternative to the current homogeneous process.

  10. Double aberration-corrected TEM/STEM of tungstated zirconia nanocatalysts for the synthesis of paracetamol

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, K; Boyes, E D; Gai, P L [York JEOL Nanocentre (United Kingdom); Shiju, N R; Brown, D R, E-mail: pgb500@york.ac.u [Department of Chemical and Biological Sciences, University of Huddersfield, Huddersfield, HD1 3DH (United Kingdom)

    2010-07-01

    We report highly active tungstated zirconia nanocatalysts for the synthesis of paracetamol by Beckmann rearrangement of 4-hydroxyacetophenone oxime. Double aberration-corrected (2AC)-TEM/STEM studies were performed in a JEOL 2200FS FEG TEM/STEM at the 1 Angstrom (1 A = 0.1 nanometer) level. Observations at close to zero defocus were carried out using the AC-TEM as well as AC-STEM including high angle annular dark field (HAADF) imaging, from the same areas of the catalyst crystallites. The studies from the same areas have revealed the location and the nanostructure of the polytungstate species (clusters) and the nanograins of zirconia. The AC (S)TEM was crucial to observe the nanostructure and location of polytungstate clusters on the zirconia grains. Polytungstate clusters as small as 0.5 nm have been identified using the HAADF-STEM. The nanostructures of the catalyst and the W surface density have been correlated with paracetamol reaction studies. The results demonstrate the nature of active sites and high activity of the tungstated zirconia nanocatalyst, which is an environmentally clean alternative to the current homogeneous process.

  11. Non-destructive local determination of doping additions and main components in single crystals

    International Nuclear Information System (INIS)

    Ehksperiandova, L.P.; Blank, A.B.; Kukhtina, N.N.; Afanasiadi, L.I.

    1994-01-01

    Procedures for local non-destructive determination of elements in optical and scintillation single crystals are developed. They are applied for determination of the main components (in cadmium tungstate) and doping additions (tellurium in zinc selenide, europium in gadolinium silicate). The metrological characteristics of the developed micro-analysis methods are estimated. Segregation of the main components and doping additions in the objects under consideration are investigated. Tellurium is found to be distributed uniformly on the cross-sections of bulk zinc selenide single crystals. The segregation of europium along gadolinium silicate ingots is almost absent. On the cross-section surface of cadmium tungstate single crystals the microregions are found characterized by the prevailing contents of cadmium or tungsten

  12. The spaghetti calorimeter. Research, development, application

    Energy Technology Data Exchange (ETDEWEB)

    Scheel, C V

    1994-12-22

    The Spaghetti Calorimeter (SPACAL) is a detector intended primarily for the energy measurement of high-energy particles, but also provides spatial information and particle identification. It is a sampling calorimeter composed of plastic scintillating fibers, oriented in the direction of the particle, embedded in lead. The scintillation light is read out by photomultipliers, which are coupled to bunches of fibers through light guides, each forming a tower. It was developed as an electromagnetic (e.m.) and compensating hadronic calorimeter for use in future multi-TeV collider experiments. The largest prototype was installed for an alternative application as an hadronic calorimeter in the WA89 experiment, where it is used for the detection of neutrons resulting from {Sigma} decays. The basic concepts behind calorimetry are discussed in detail. Several prototypes were tested in beams of electrons and pions with energies up to 150 GeV. Resonable e.m. energy resolution, at {sigma}/E=12.9%/{radical}E[GeV]+1.23%, was measured. Excellent hadronic energy resolution was found, at 30.6%/{radical}E[GeV]+1.0%, but the calorimeter was found to be slightly undercompensating with e/h=1.15. The position of the shower barycenter for both electrons and pions was easily found according to the relative energy deposits in the calorimeter towers. The calorimeter was also found to be able to provide effective discrimination between electrons and hadrons. The performance of SPACAL in the WA89 experiment at the Omega spectrometer at CERN was studied with the reconstruction of beam {Sigma}{sup -}particles via its decay {Sigma}{sup -}{yields}n{pi}{sup -}. Details of the calibration of SPACAL with electrons and protons are presented. (orig.).

  13. The spaghetti calorimeter. Research, development, application

    International Nuclear Information System (INIS)

    Scheel, C.V.

    1994-01-01

    The Spaghetti Calorimeter (SPACAL) is a detector intended primarily for the energy measurement of high-energy particles, but also provides spatial information and particle identification. It is a sampling calorimeter composed of plastic scintillating fibers, oriented in the direction of the particle, embedded in lead. The scintillation light is read out by photomultipliers, which are coupled to bunches of fibers through light guides, each forming a tower. It was developed as an electromagnetic (e.m.) and compensating hadronic calorimeter for use in future multi-TeV collider experiments. The largest prototype was installed for an alternative application as an hadronic calorimeter in the WA89 experiment, where it is used for the detection of neutrons resulting from Σ decays. The basic concepts behind calorimetry are discussed in detail. Several prototypes were tested in beams of electrons and pions with energies up to 150 GeV. Resonable e.m. energy resolution, at σ/E=12.9%/√E[GeV]+1.23%, was measured. Excellent hadronic energy resolution was found, at 30.6%/√E[GeV]+1.0%, but the calorimeter was found to be slightly undercompensating with e/h=1.15. The position of the shower barycenter for both electrons and pions was easily found according to the relative energy deposits in the calorimeter towers. The calorimeter was also found to be able to provide effective discrimination between electrons and hadrons. The performance of SPACAL in the WA89 experiment at the Omega spectrometer at CERN was studied with the reconstruction of beam Σ - particles via its decay Σ - →nπ - . Details of the calibration of SPACAL with electrons and protons are presented. (orig.)

  14. A new ultrasensitive scanning calorimeter.

    Science.gov (United States)

    Plotnikov, V V; Brandts, J M; Lin, L N; Brandts, J F

    1997-08-01

    A new ultrasensitive differential scanning calorimeter is described, having a number of novel features arising from integration between hardware and software. It is capable of high performance in either a scanning or isothermal mode of operation. Upscanning is carried out adiabatically while downscanning is nonadiabatic. By using software-controlled signals sent continuously to appropriate hardware devices, it is possible to improve adiabaticity and constancy of scan rate through use of empirical prerun information stored in memory rather than by using feedback systems which respond in real time and generate thermal noise. Also, instrument response time is software-selectable, maximizing performance for both slow- and fast-transient systems. While these and other sophisticated functionalities have been introduced into the instrument to improve performance and data analysis, they are virtually invisible and add no additional complexities into operation of the instrument. Noise and baseline repeatability are an order of magnitude better than published raw data from other instruments so that high-quality results can be obtained on protein solutions, for example, using as little as 50 microg of protein in the sample cell.

  15. Tritium calorimeter setup and operation

    International Nuclear Information System (INIS)

    Rodgers, David E.

    2002-01-01

    The LBNL tritium calorimeter is a stable instrument capable of measuring tritium with a sensitivity of 25 Ci. Measurement times range from 8-hr to 7-days depending on the thermal conductivity and mass of the material being measured. The instrument allows accurate tritium measurements without requiring that the sample be opened and subsampled, thus reducing personnel exposure and radioactive waste generation. The sensitivity limit is primarily due to response shifts caused by temperature fluctuation in the water bath. The fluctuations are most likely a combination of insufficient insulation from ambient air and precision limitations in the temperature controller. The sensitivity could probably be reduced to below 5 Ci if the following improvements were made: (1) Extend the external insulation to cover the entire bath and increase the top insulation. (2) Improve the seal between the air space above the bath and the outside air to reduce evaporation. This will limit the response drift as the water level drops. (3) Install an improved temperature controller, preferably with a built in chiller, capable of temperature control to ±0.001 C

  16. Hadron showers in a highly granular calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, Benjamin

    2010-11-15

    A future electron-positron collider like the planned International Linear Collider (ILC) needs excellent detectors to exploit the full physics potential. Different detector concepts have been evaluated for the ILC and two concepts on the particle-flow approach were validated. To make particle-flow work, a new type of imaging calorimeters is necessary in combination with a high performance tracking system, to be able to track the single particles through the full detector system. These calorimeters require an unprecedented level of both longitudinal and lateral granularity. Several calorimeter technologies promise to reach the required readout segmentation and are currently studied. This thesis addresses one of these: The analogue hadron calorimeter technology. It combines work on the technological aspects of a highly granular calorimeter with the study of hadron shower physics. The analogue hadron calorimeter technology joins a classical scintillator-steel sandwich design with a modern photo-sensor technology, the silicon photomultiplier (SiPM). The SiPM is a millimetre sized, magnetic field insensitive, and low cost photo-sensor, that opens new possibilities in calorimeter design. This thesis outlines the working principle and characteristics of these devices. The requirements for an application specific integrated circuit (ASIC) to read the SiPM are discussed; the performance of a prototype chip for SiPM readout, the SPIROC, is quantified. Also the SiPM specific reconstruction of a multi-thousand channel prototype calorimeter, the CALICE AHCAL, is explained; the systematic uncertainty of the calibration method is derived. The AHCAL does not only offer a test of the calorimeter technology, it also allows to record hadron showers with an unprecedented level of details. Test-beam measurements have been performed with the AHCAL and provide a unique sample for the development of novel analysis techniques and the validation of hadron shower simulations. A method to

  17. Hadron showers in a highly granular calorimeter

    International Nuclear Information System (INIS)

    Lutz, Benjamin

    2010-11-01

    A future electron-positron collider like the planned International Linear Collider (ILC) needs excellent detectors to exploit the full physics potential. Different detector concepts have been evaluated for the ILC and two concepts on the particle-flow approach were validated. To make particle-flow work, a new type of imaging calorimeters is necessary in combination with a high performance tracking system, to be able to track the single particles through the full detector system. These calorimeters require an unprecedented level of both longitudinal and lateral granularity. Several calorimeter technologies promise to reach the required readout segmentation and are currently studied. This thesis addresses one of these: The analogue hadron calorimeter technology. It combines work on the technological aspects of a highly granular calorimeter with the study of hadron shower physics. The analogue hadron calorimeter technology joins a classical scintillator-steel sandwich design with a modern photo-sensor technology, the silicon photomultiplier (SiPM). The SiPM is a millimetre sized, magnetic field insensitive, and low cost photo-sensor, that opens new possibilities in calorimeter design. This thesis outlines the working principle and characteristics of these devices. The requirements for an application specific integrated circuit (ASIC) to read the SiPM are discussed; the performance of a prototype chip for SiPM readout, the SPIROC, is quantified. Also the SiPM specific reconstruction of a multi-thousand channel prototype calorimeter, the CALICE AHCAL, is explained; the systematic uncertainty of the calibration method is derived. The AHCAL does not only offer a test of the calorimeter technology, it also allows to record hadron showers with an unprecedented level of details. Test-beam measurements have been performed with the AHCAL and provide a unique sample for the development of novel analysis techniques and the validation of hadron shower simulations. A method to

  18. Study on preparation of ultrafine lead tungstate for radiation protection and γ-ray shielding of the gloves

    International Nuclear Information System (INIS)

    Du Licheng; He Ping; Zhou Yuanlin; Song Kaiping; Yang Kuihua

    2012-01-01

    Lead tungstate combines the radiation shielding properties of tungsten and lead, and it is quite distinctive to manufacture lead tungstate with ultra-fine granularity to enhance its capacity of radiation shielding. The grain size of lead tungstate has direct impact on the ability of its protection from radioactive materials. the smaller the grain size and more uniform dispersion of lead tungstate, the better protective ability it is going to be. In this paper, soft-template synthesis was introduced to prepare ultra-fine PbWO 4 . Rigorous experiment conditions are settled to ensure the access to obtain ultra-fine, homogeneous lead tungstate product, and it is better than other physical and chemical preparation methods. The surface-active agent for the soft template, with S-60 for the water system W/O microemulsion zone, was used to synthesize successfully ultra-fine PbWO 4 . It was shown that dispersing agent S-60 in the soft template method produced ultra-fine PbWO 4 with uniform granularity distribution. By using orthogonal experimental method, the best experimental conditions were obtained as follows: S-60 as surfactant dispersant with diluted 30 times concentration, solutions with pH9, 0.01 mol/L concentration of reactant, 1300 rpm of stirring speed and slowly adding drops of Na 2 WO 4 solution into Pb (Ac) 2 solution. Based on the optimal experimental conditions, the product of ultra-fine product for the anti-radiation protection filler has been made. The fine packing for the preparation of tungsten the gamma rays on the gloves is an average capacity of 5% or so. (authors)

  19. The H1 liquid argon calorimeter system

    International Nuclear Information System (INIS)

    Andrieu, B.; Babayev, A.; Ban, J.

    1993-06-01

    The liquid argon calorimeter of the H1 detector presently taking data at the HERA ep - collider at DESY, Hamburg, is described here. The main physics requirements and the most salient design features relevant to this calorimeter are given. The aim to have smooth and hermetic calorimetric coverage over the polar angular range 4 ≤ θ ≤ 154 is achieved by a single liquid argon cryostat containing calorimeter stacks structured in wheels and octants for easy handling. The absorber materials used are lead in the electromagnetic part and stainless steel in the hadronic part. The read-out system is pipelined to reduce the dead time induced by the high trigger rate expected at the HERA collider where consecutive bunches are separated in time by 96 ns. The main elements of the calorimeter, such as the cryostat, with its associated cryogenics, the stack modules, the read-out, calibration and trigger electronics as well as the data acquisition system are described. Performance results from data taken in calibration runs with full size H1 calorimeter stacks at a CERN test beam, as well as results from data collected with the complete H1 detector using cosmic rays during the initial phase of ep operations are presented. The observed energy resolutions and linearities are well in agreement with the requirements. (orig.)

  20. A water flow calorimeter calibration system

    International Nuclear Information System (INIS)

    Ullrich, F.T.

    1983-01-01

    Neutral beam systems are instrumented by several water flow calorimeter systems, and some means is needed to verify the accuracy of such systems and diagnose their failures. This report describes a calibration system for these calorimeters. The calibrator consists of two 24 kilowatt circulation water heaters, with associated controls and instrumentation. The unit can supply power from 0 to 48 kW in five coarse steps and one fine range. Energy is controlled by varying the power and the time of operation of the heaters. The power is measured by means of precision power transducers, and the energy is measured by integrating the power with respect to time. The accuracy of the energy measurement is better than 0.5% when the power supplied is near full scale, and the energy resolution is better than 1 kilojoule. The maximum energy delivered is approximately 50 megajoules. The calorimetry loop to be calibrated is opened, and the calibrator is put in series with the calorimeter heat source. The calorimeter is then operated in its normal fashion, with the calibrator used as the heat source. The calibrator can also be used in a stand alone mode to calibrate calorimeter sensors removed from systems

  1. LHCb Calorimeter modules arrive at CERN

    CERN Multimedia

    2002-01-01

    Two of the three components of the LHCb Calorimeter system have started to arrive from Russia. Members of the LHCb Calorimeter group with the ECAL and HCAL modules that have just arrived at CERN. The first two of the 56 Hadron Calorimeter (HCAL) modules and 1200 of the 3300 modules of the Electromagnetic Calorimeter (ECAL) have reached CERN from Russia. The third part of the system, the Preshower detector, is still being prepared in Russia. The calorimeter system identifies and triggers on high-energy particles, namely electrons, hadrons and photons by measuring their positions and energies. The HCAL is going to be a pure trigger device. The ECAL will also be used in the triggering, but in addition it will reconstruct neutral pions and photons from B meson decays. One of the major aims of the LHCb experiment is to study CP violation through B meson decays including Bs mesons with high statistics in different decay modes. CP violation (violation of charge and parity) is necessary to explain why the Universe...

  2. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Bartos, Pavol; The ATLAS collaboration

    2016-01-01

    Performance of the ATLAS hadronic Tile calorimeter The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter have been studied in-situ employing cosmic ray muons and a large sample of proton-proton collisions acquired during the operations o...

  3. ATLAS Tile calorimeter calibration and monitoring systems

    Science.gov (United States)

    Chomont, Arthur; ATLAS Collaboration

    2017-11-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises cesium radioactive sources, Laser and charge injection elements, and allows for monitoring and equalization of the calorimeter response at each stage of the signal production, from scintillation light to digitization. Based on LHC Run 1 experience, several calibration systems were improved for Run 2. The lessons learned, the modifications, and the current LHC Run 2 performance are discussed.

  4. CsI electromagnetic calorimeter development for a low or medium energy e+e- collider

    International Nuclear Information System (INIS)

    King, M.E.

    1993-10-01

    Design considerations for an electromagnetic Csl calorimeter suitable for use at low and medium energy, high-luminosity e + e - storage rings are presented, together with results of a test of an array of Csl(Tl) crystals in an e - /π - beam (120 to 400 MeV) at TRIUMF. The crystal array used in the test was designed to explore longitudinal and transverse crystal segmentation, and a redundant wavelength-shifter and photodiode readout system. Energy resolution of (1.69 ± 0.08)%/√E and (1.83 ± 0.05)%/√E was obtained for two different crystal tower configurations. Position resolution of 6.5 (9.0) mm was obtained at 300 (120)MeV for four 4x4 cm 2 , 4 rl. Csl crystals

  5. The Dynamic Characteristic Analysis of Mini Gamma Calorimeter

    International Nuclear Information System (INIS)

    Setiyanto

    2004-01-01

    The gamma calorimeter is a facility to measure the gamma heating in the nuclear reactor. The dimensions of the conventional calorimeters are in general too large, that is an inconvenience if those calorimeters will be applied in the high temperature reactor as a nuclear power plant. To avoid that inconvenience, it is necessary to propose the innovation on the feature of the existing calorimeter. The basic idea of the innovation is to create the small type of calorimeter without the absorbed material. The last analysis was realized to determine of the static calorimeter characteristic or sensitivities as a function of the dimension and the material of gas isolations. Based on those results, the analyses is reasonably to be continued to determine the dynamic characteristic or period of calorimeter. The analysis was performed using the finite difference method, two dimension simplified. It can be concluded that the mini gamma calorimeter proposed is reasonable to be made. (author)

  6. To the calculation of energy resolution of ionization calorimeter

    International Nuclear Information System (INIS)

    Uchajkin, V.V.; Lagutin, A.A.

    1976-01-01

    The question of energy resolution of the ionization calorimeter is considered analytically. A method is discussed for calculating the probability characteristics (mean value and dispersion) of energy losses of an electron-photon shower by ionization in the calorimeter volume

  7. Performance of a shashlik calorimeter at LEP II

    CERN Document Server

    Ferrari, P; Klovning, A; Maeland, O A; Stugu, B; Benvenuti, Alberto C; Giordano, V; Guerzoni, M; Navarria, Francesco Luigi; Verardi, M G; Camporesi, T; Bozzo, M; Cereseto, R; Barreira, G; Espirito-Santo, M C; Maio, A; Onofre, A; Peralta, L; Pimenta, M; Tomé, B; Carling, H; Falk, E; Hedberg, V; Jarlskog, G; Kronkvist, I J; Bonesini, M; Chignoli, F; Gumenyuk, S A; Leoni, R; Mazza, R; Negri, P; Paganoni, M; Petrovykh, L P; Terranova, F; Dharmasiri, D R; Nossum, B; Read, A L; Skaali, T B; Castellani, L; Pegoraro, M; Fenyuk, A; Guz, Yu; Karyukhin, A N; Konoplyannikov, A K; Obraztsov, V F; Shalanda, N A; Vlasov, E; Zaitsev, A; Bigi, M; Cassio, V; Gamba, D; Migliore, E; Romero, A; Simonetti, L; Torassa, E; Trapani, P P; Bari, M D; Della Ricca, G; Lanceri, L; Poropat, P; Prest, M; Vallazza, E

    1999-01-01

    The small angle tile calorimeter (STIC) is a sampling lead- scintillator calorimeter, built with "shashlik" technique. Results are presented from extensive studies of the detector performance at LEP. (5 refs).

  8. Detailed GEANT description of the SDC central calorimeters

    International Nuclear Information System (INIS)

    Glagolev, V.V.; Li, W.

    1994-01-01

    This article represents the very detailed simulation model of the SDC central calorimeters and some results which were obtained using that model. The central calorimeters structure was coded on the GEANT 3.15 base in the frame of the SDCSIM environment. The SDCSIM is the general shell for simulation of the SDC set-up. The calorimeters geometry has been coded according to the FNAL and ANL engineering drawings and engineering data file. SDC central calorimeters detailed description is extremely useful for different simulation tasks, for fast simulation program parameters tuning, for different geometry especially studying (local response nonuniformity from bulkheads in the e.m. calorimeter and from coil supports and many others) and for the interpretation of the experimental data from the calorimeters. This simulation model is very useful for tasks of the test beam modules calorimeter calibration and for calorimeter in situ calibration. 3 refs., 8 figs

  9. Calorimeter based detectors for high energy hadron colliders

    International Nuclear Information System (INIS)

    Marx, M.D.; Rijssenbeek, M.

    1990-01-01

    This report discusses the following topics: the central calorimeter; and installation; commissioning; and calorimeter beam tests; the central drift chamber; cosmic ray and beam tests; chamber installation and commissioning; and software development; and SSC activities: the EMPACT project

  10. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  11. Feasibility of a Mound-designed transportable calorimeter

    International Nuclear Information System (INIS)

    Duff, M.F.; Fellers, C.L.

    1979-01-01

    The feasibility of operating a Mound twin resistance bridge calorimeter outside a temperature-controlled water bath was demonstrated. An existing calorimeter was retrofit with two additional jackets through which water was transferred from an external reservoir. Comparison of test results collected before and after the retrofit indicated that the calorimeter performance was not degraded by this modification. Similarly designed calorimeters have potential applications in laboratories where equipment space is limited for inspectors who are required to transport their assay instrumentation

  12. Laser calibration of the ATLAS Tile Calorimeter

    CERN Document Server

    Di Gregorio, Giulia; The ATLAS collaboration

    2017-01-01

    High performance stability of the ATLAS Tile calorimeter is achieved with a set of calibration procedures. One step of the calibrtion procedure is based on measurements of the response stability to laser excitation of the photomultipliers (PMTs) that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the test in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the resonse drifts seen with the PMT mounted on the Tile calorimeter in its normal operation during LHC run I and run II. A new statistical approach was developed to measure the drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to the data collected in the Pisa local laboratory. The preliminary results from these two studies are shown.

  13. Optics robustness of the ATLAS Tile Calorimeter

    CERN Document Server

    Costa Batalha Pedro, Rute; The ATLAS collaboration

    2018-01-01

    TileCal, the central hadronic calorimeter of the ATLAS detector is composed of plastic scintillators interleaved by iron plates, and wavelength shifting optical fibres. The optical properties of these components are known to suffer from natural ageing and degrade due to exposure to radiation. The calorimeter was designed for 10 years of LHC operating at the design luminosity of $10^{34}$ cm$^{-1}$s$^{-1}$. Irradiation tests of scintillators and fibres shown that their light yield decrease about 10 for the maximum dose expected after the 10 years of LHC operation. The robustness of the TileCal optics components is evaluated using the calibration systems of the calorimeter: Cs-137 gamma source, laser light, and integrated photomultiplier signals of particles from collisions. It is observed that the loss of light yield increases with exposure to radiation as expected. The decrease in the light yield during the years 2015-2017 corresponding to the LHC Run 2 will be reported.

  14. Vacuum-jacketed hydrofluoric acid solution calorimeter

    Science.gov (United States)

    Robie, R.A.

    1965-01-01

    A vacuum-jacketed metal calorimeter for determining heats of solution in aqueous HF was constructed. The reaction vessel was made of copper and was heavily gold plated. The calorimeter has a cooling constant of 0.6 cal-deg -1-min-1, approximately 1/4 that of the air-jacketed calorimeters most commonly used with HF. It reaches equilibrium within 10 min after turning off the heater current. Measurements of the heat of solution of reagent grade KCl(-100 mesh dried 2 h at 200??C) at a mole ratio of 1 KCl to 200 H2O gave ??H = 4198??11 cal at 25??C. ?? 1965 The American Institute of Physics.

  15. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Boumediene, Djamel Eddine; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). PMT signals are then digitized at 40 MHz and stored on detector and are only transferred off detector once the first level trigger acceptance has been confirmed. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator b...

  16. Laser Calibration of the ATLAS Tile Calorimeter

    CERN Document Server

    Di Gregorio, Giulia; The ATLAS collaboration

    2017-01-01

    High performance stability of the ATLAS Tile Calorimeter is achieved with a set of calibration procedures. One step of the calibration procedure is based on measurements of the response stability to laser excitation of the PMTs that are used to readout the calorimeter cells. A facility to study in lab the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests in lab are to study the time evolution of the PMT response to reproduce and to understand the origin of the response drifts seen with the PMT mounted on the Tile calorimeter in its normal operating during LHC run I and run II. A new statistical approach was developed to measure drift of the absolute gain. This approach was applied to both the ATLAS laser calibration data and to data collected in the Pisa local laboratory. The preliminary results from these two studies are shown.

  17. A LYSO Calorimeter for the SuperB Factory

    Energy Technology Data Exchange (ETDEWEB)

    Cecchi, Claudia; Germani, Stefano; Manoni, Elisa; Rossi, Alessandro; Bizzarri, Marco [Universita di Perugia e INFN Sezione di Perugia Via A. Pascoli, 06123 Perugia (Italy); Bocci, Valerio; Chiodi, Giacomo; Recchia, Luigi [Universita di Roma ' La Sapienza' e INFN Sezione di Roma1 P.zzle Aldo Moro 2, 00185 Roma (Italy); Lubrano, Pasquale; Lebeau, Michel; Papi, Andrea, E-mail: claudia.cecchi@pg.infn.it [Istituto Nazionale di Fisica Nucleare, INFN Sezione di Perugia, Via A. Pascoli, 06123 Perugia (Italy)

    2011-04-01

    The SuperB project is an asymmetric e{sup +}e{sup -} accelerator of 10{sup 36} cm{sup -2}s{sup -1} luminosity, capable of collecting a data sample of 50-75 ab{sup -1} in five years of running. The SuperB electromagnetic calorimeter (EMC), that will be described in this paper, provides energy and direction measurement of photons and electrons, and is used for identification of electrons versus other charged particles. In particular we will present its design, geometry study and related simulations, as well as R and D on LYSO crystals, a project for the mechanical structure and development on readout and electronics. A matrix of 6 crystals has been tested this year June 2010 at the Beam Test Facility of Frascati (BTF) at energies between 200 MeV and 500 MeV, and a beam test with the complete prototype of 25 crystals is foreseen at CERN in October 2010 to cover the energy range between 500 MeV and 7 GeV.

  18. Sensors for the CMS High Granularity Calorimeter

    CERN Document Server

    Maier, Andreas Alexander

    2017-01-01

    The CMS experiment is currently developing high granularity calorimeter endcapsfor its HL-LHC upgrade. The design foresees silicon sensors as the active material for the high radiation region close to the beampipe. Regions of lower radiation are additionally equipped with plastic scintillator tiles. This technology is similar to the calorimeter prototypes developed in the framework of the Linear Collider by the CALICE collaboration. The current status of the silicon sensor development is presented. Results of single diode measurements are shown as well as tests of full 6-inch hexagonal sensor wafers. A short summary of test beam results concludes the article.

  19. Nonuniformities in organic liquid ionization calorimeters

    International Nuclear Information System (INIS)

    Wenzel, W.A.

    1989-06-01

    Hermeticity and uniformity in SSC calorimeter designs are compromised by structure and modularity. Some of the consequences of the cryogenic needs of liquid argon calorimetry are relatively well known. If the active medium is an organic liquid (TMP, TMS, etc.), a large number of independent liquid volumes is needed for safety and for rapid liquid exchange to eliminate local contamination. Modular construction ordinarily simplifies fabrication, assembly, handling and preliminary testing at the price of additional walls, other dead regions and many nonuniformities. Here we examine ways of minimizing the impact of some generic nonuniformities on the quality of calorimeter performance. 6 refs., 7 figs

  20. Rad Hard Active Media For Calorimeters

    CERN Document Server

    Norbeck, E; Möller, A; Onel, Y

    2006-01-01

    Zero-degree calorimeters have limited space and extreme levels of radiation. A simple, low cost, radiation hard design uses tungstenmetal as the absorber and a suitable liquid as the ˇCerenkov radiator. In other applications a PPAC (Parallel Plate Avalanche Counter) operatingwith a suitable atmosphericpressure gas is an attractive active material for a calorimeter. It can be made radiation hard and has sufficient gain in the gas that no electronic components are needed near the detector. It works well even with the highest concentration of shower particles. For this pressure range, R134A (used in auto air conditioners) has many desirable features.

  1. Fast shower simulation in the ATLAS calorimeter

    CERN Document Server

    Barberio, E; Butler, B; Cheung, S L; Dell'Acqua, A; Di Simone, A; Ehrenfeld, W; Gallas, M V; Glazov, A; Marshall, Z; Müller, J; Placakyte, R; Rimoldi, A; Savard, P; Tsulaia, V; Waugh, A; Young, C C

    2008-01-01

    The time to simulate pp collisions in the ATLAS detector is largely dominated by the showering of electromagnetic particles in the heavy parts of the detector, especially the electromagnetic barrel and endcap calorimeters. Two procedures have been developed to accelerate the processing time of electromagnetic particles in these regions: (1) a fast shower parameterisation and (2) a frozen shower library. Both work by generating the response of the calorimeter to electrons and positrons with Geant 4, and then reintroduce the response into the simulation at runtime.

  2. Commissioning of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Cooke, M; The ATLAS collaboration

    2009-01-01

    Since the first modules of the ATLAS LAr calorimeters were read out in situ in 2006, commissioning studies have been performed. These studies include the testing of the electronics calibration system, surveys for dead or problematic channels, investigations of the quality of the physics pulse shape prediction , and tests of energy and time reconstruction with cosmic or single beam induced signals. The results of these commissioning studies indicate the LAr calorimeters are prepared for LHC collisions and positioned to meet the physics objectives of the ATLAS experiment.

  3. Radiation damage effects on calorimeter compensation

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Handler, T.

    1990-01-01

    An important consideration in the design of a detector that is to be used at the Superconducting Super Collider (SSC) is the response of the calorimeter to electromagnetic and hadronic particles and the equality of those responses for different types of particles at equal incident energies, i.e. compensation. However, as the simulations that are reported show, the compensation characteristics of a calorimeter can be seriously compromised over a relatively short period of time due to the large radiation levels that are expected in the SSC environment. 6 refs., 3 figs

  4. Comparison between calorimeter and HLNC errors

    International Nuclear Information System (INIS)

    Goldman, A.S.; De Ridder, P.; Laszlo, G.

    1991-01-01

    This paper summarizes an error analysis that compares systematic and random errors of total plutonium mass estimated for high-level neutron coincidence counter (HLNC) and calorimeter measurements. This task was part of an International Atomic Energy Agency (IAEA) study on the comparison of the two instruments to determine if HLNC measurement errors met IAEA standards and if the calorimeter gave ''significantly'' better precision. Our analysis was based on propagation of error models that contained all known sources of errors including uncertainties associated with plutonium isotopic measurements. 5 refs., 2 tabs

  5. Comparison of the Heat Release Rate from the Mass Loss Calorimeter to the Cone Calorimeter for Wood-based Materials

    Science.gov (United States)

    Laura E. Hasburgh; Robert H. White; Mark A. Dietenberger; Charles R. Boardman

    2015-01-01

    There is a growing demand for material properties to be used as inputs in fi re behavior models designed to address building fire safety. This comparative study evaluates using the mass loss calorimeter as an alternative to the cone calorimeter for obtaining heat release rates of wood-based materials. For this study, a modified mass loss calorimeter utilized an...

  6. Vanadia-based SCR Catalysts Supported on Tungstated and Sulfated Zirconia: Influence of Doping with Potassium

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Boghosian, Soghomon; Kustov, Arkadii

    2007-01-01

    A series of vanadium-based SCR catalysts supported on sulfated or tungstated ZrO2 were synthesized and characterized by means of N2-BET, XRD, NH3-TPD and in situ Raman spectroscopy. The effect of potassium doping on the properties of vanadia species is studied in detail. A number of catalyst...... and morphology, the surface composition and the molecular configuration of the dispersed vanadates. It was observed that poisoning with potassium had a negligible effect on the surface vanadate species (especially the V=O stretching frequency observed by in situ Raman spectroscopy) if supported on the sulfated...... the observed decrease in V=O stretching frequency and the higher proportion of dimers and higher polymers through coordination between K+ and two neighbouring V=O. The results suggest an increased resistance towards potassium doping for the vanadia-based catalysts supported on sulfated zirconia....

  7. Synthesis and characterization of rare-earth-doped calcium tungstate nanocrystals

    Science.gov (United States)

    Suneeta, P.; Rajesh, Ch.; Ramana, M. V.

    2018-02-01

    In this paper, we report synthesis and characterization of rare-earth-ion-doped calcium tungstate (CaWO4) nanocrystals (NCs). Rare-earth ions, such as gadolinium (Gd), neodymium (Nd), praseodymium (Pr), samarium (Sm) and holmium (Ho), were successfully doped in the CaWO4 NCs by changing the synthesis conditions. The adopted synthesis route was found to be fast and eco-friendly. Structural characterizations, such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and compositional analysis, were performed using energy dispersive analysis of X-rays (EDAX) on as-synthesized NCs. The results indicate the size of the NCs ranging between 47 to 68nm and incorporation of rare-earth ions in CaWO4 NCs.

  8. Tungstated zirconia as promising carrier for DeNOx catalysts with improved resistance towards alkali poisoning

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Kustov, Arkadii; Rasmussen, Søren Birk

    2006-01-01

    Use of biomass as an alternative to fossil fuels has achieved increasing interest since it is considered neutral regarding CO2 accumulation in the atmosphere. The by far most energy-efficient use of solid bio-resources in energy production is combustion in combined biomass and coal or oilfired...... of new alternative catalysts that are more resistant towards poisoning with potassium. Vanadia-based catalysts supported on traditional and tungstated zirconia has been prepared and tested in selective catalytic reduction of NO with ammonia. All prepared catalysts were characterized using N2-BET, XRD......, and NH3-TPD methods. The influence of calcination temperature of zirconia modified with tungsten oxide on the textural characteristics, acidity and catalytic performance was studied. The resistance of the catalysts towards model poisoning with potassium was found to depend dramatically...

  9. Synthesis of gels with basis of titanium tungstates as matrixes of radioactive generators

    International Nuclear Information System (INIS)

    Galico C, L.

    2005-01-01

    The heteropolyanions, compounds formed by the union of molybdates or tungstates polyanions with atoms of metals like zirconium, titanium, cerium, thorium, tin, etc., have been used as generator matrixes of 99m Tc or 188 Re. Particularly they have been studied and produced successfully in our laboratory, generators of 99 Mo/ 99 m Tc at basis of gels zirconium molybdates and titanium molybdates. Considering that the molybdenum and tungsten, as well as the technetium and the rhenium, its belong to the same groups of transition metals, it is feasible that gels can be synthesized at basis of titanium tungstates, continuing a methodology similar to that of the gels titanium molybdates or zirconium molybdates, to produce generators 188 W/ 188 Re. The 188 Re possess nuclear characteristics that make it attractive for therapeutic applications, since, it emits β - particles of a great energy (2.12 MeV); joined to the possibility of being able to unite to different ligands (bifunctional agents) and biomolecules (antibodies or fragments of proteins), as it makes the 99m Tc, useful in radioimmunotherapy. Commercially the 188 Re generators use a chromatographic column loaded with alumina where the 188 Re, it is adsorbed and eluted the 188 ReO 4 - by means of a saline solution The alumina adsorbs around 0.2% of the 188 Re, situation that forces to use 188 Re of a high specific activity. The use of the gels technology, allows to work with medium or low specific activities of 188 Re, opening the possibility of their production in countries whose nuclear capacity is medium or low. In particular, the synthesized gels with basis of titanium offer the possibility of being synthesized with non active material, for later on to be irradiated and directly produce the generator, since, the titanium 51 Ti, unique radioisotope produced by the titanium, has a half life of 5.79 min. This synthesis method avoids the manipulation of radioactive material during the synthesis of the gels, process

  10. Integrated lasers in crystalline double tungstates with focused-ion-beam nanostructured photonic cavities

    International Nuclear Information System (INIS)

    Ay, F; Iñurrategui, I; Geskus, D; Aravazhi, S; Pollnau, M

    2011-01-01

    Deeply etched Bragg gratings were fabricated by focused ion beam (FIB) milling in KGd x Lu 1-x (WO 4 ) 2 :Yb 3+ to obtain photonic cavity structures. By optimizing parameters such as dose per area, dwell time and pixel resolution the redeposition effects were minimized and grating structures more than 4 μm in depth with an improved sidewall angle of ∼ 5° were achieved. Fabry-Perot microcavities were defined and used to assess the optical performance of the grating structures at ∼ 1530 nm. An on-chip integrated laser cavity at ∼ 980 nm was achieved by defining a FIB reflective grating and FIB polished waveguide end-facet. With this cavity, an on-chip integrated waveguide laser in crystalline potassium double tungstate was demonstrated

  11. Properties of complex tungstates, niobates, translated with fluorite-like structure

    International Nuclear Information System (INIS)

    Vetkina, S.N.; Zolin, V.F.; Sirotinkin, V.P.; Smirnov, S.A.

    1989-01-01

    Spectra of ternary tungstates, niobates and tantalates (MeLa 2 WO 7 , La 3 TO 7 ; Me=Ba, Sr; T=Ta, Nb) related to the layered fluorite group are analyzed. The laser pumping and time resolved luminescence are used for selecting spectra of unequivalent centers. The symmetry of the first center is near to the distorted cubic one. The vibrational spectra of europium in Eu 3 NbO 7 and SrLa 2 WO 7 are due to the chain-like structure of niobates and to the net-like structure of tantalates. The stimulated emission of Nd 3+ in powders of BaLa 2 WO 7 and La 3 NbO 7 is observed at wavelengths of 1.07 and 1.063 μm, respectively

  12. Synthesis and Characterization of Tin (IV Tungstate Nanoparticles – A Solid Acid Catalyst

    Directory of Open Access Journals (Sweden)

    Manoj Sadanandan

    2012-12-01

    Full Text Available Tin (IV tungstate, a tetravalent metal acid salt was synthesized in the nanoform by chemical coprecipitation method using EDTA as capping agent. The material was found to be stable in mineral acids, bases and organic solvents except  in HF and aquaregia. The material was characterized using EDS, TG/DTA, FTIR, XRD, SEM, HRTEM and BET surface area measurement. The molecular formula of the compound is 2SnO2 3WO3.5H2O determined from elemental analysis using TG/DTA. Surface morphology and particle size were obtained using SEM and HRTEM. The surface area was found to be 205-225m2/g. The Na+ exchange capacity found to be 3.8 meq/g, indicates the presence of surface hydroxyl group and hence the presence of Bronsted acid sites. The catalytic activity of the material was tested by using esterification and oxidation as model reactions. For the esterification of different alcohols, the percentage yield was found to be high for n-alcohol compared to isomeric alcohols. Oxidation of benzyl alcohol gives benzaldehyde and benzoic acid as the only products. Copyright © 2012 by BCREC UNDIP. All rights reservedReceived: 12nd June 2012, Revised: 23rd July 2012, Accepted: 29th July 2012[How to Cite: S. Manoj, R. Beena, (2012. Synthesis and Characterization of tin(IV Tungstate Nanoparticles – A Solid Acid Catalyst. Bulletin of Chemical Reaction Engineering & Catalysis, 7 (2: 105-111. doi:10.9767/bcrec.7.2.3622.105-111] [How to Link / DOI: http://dx.doi.org/10.9767/bcrec.7.2.3622.105-111 ] | View in 

  13. Novel rattling of K atoms in aluminium-doped defect pyrochlore tungstate

    International Nuclear Information System (INIS)

    Shoko, Elvis; Kearley, Gordon J; Peterson, Vanessa K; Thorogood, Gordon J; Mutka, Hannu; Koza, Michael M; Yamaura, Jun-ichi; Hiroi, Zenji

    2014-01-01

    Rattling dynamics have been identified as fundamental to superconductivity in defect pyrochlore osmates and aluminium vanadium intermetallics, as well as low thermal conductivity in clathrates and filled skutterudites. Combining inelastic neutron scattering (INS) measurements and ab initio molecular dynamics (MD) simulations, we use a new approach to investigate rattling in the Al-doped defect pyrochlore tungstates: AAl 0.33 W 1.67 O 6 (A = K, Rb, Cs). We find that although all the alkali metals rattle, the rattling of the K atoms is unique, not only among the tungstates but also among the analogous defect osmates, KOs 2 O 6 and RbOs 2 O 6 . Detailed analysis of the MD trajectories reveals that two unique features set the K dynamics apart from the rest, namely, (1) quasi one-dimensional local diffusion within a cage, and (2) vibration at a range of frequencies. The local diffusion is driven by strongly anharmonic local potentials around the K atoms exhibiting a double-well structure in the direction of maximum displacement, which is also the direction of local diffusion. On the other hand, vibration at a range of frequencies is a consequence of the strong anisotropy in the local potentials around the K atoms as revealed by directional magnitude spectra. We present evidence to show that it is the smaller size rather than the smaller mass of the K rattler which leads to the unusual dynamics. Finally, we suggest that the occurrence of local diffusion and vibration at a range of frequencies in the dynamics of a single rattler, as found here for the K atoms, may open new possibilities for phonon engineering in thermoelectric materials. (paper)

  14. Tungstate-based glass-ceramics for the immobilization of radio cesium

    Science.gov (United States)

    Drabarek, Elizabeth; McLeod, Terry I.; Hanna, John V.; Griffith, Christopher S.; Luca, Vittorio

    2009-02-01

    The preparation of tungstate-containing glass-ceramic composites (GCC) for the potential immobilization of radio cesium has been considered. The GCC materials were prepared by blending two oxide precursor compositions in various proportions. These included a preformed Cs-containing hexagonal tungsten bronze (HTB) phase (Cs 0.3Ti 0.2W 0.8O 3, P6 3/ mcm) and a blend of silica and other oxides. The use of the HTB phase was motivated on the assumption that a HTB-based adsorbent could be used to remove cesium directly from aqueous high level liquid waste feeds. In the absence of the HTB, glass-ceramics were relatively easily prepared from the Cs-containing glass-forming oxide blend. On melting the mixture a relative complex GCC phase assemblage formed. The principal components of this phase assemblage were determined using X-ray powder diffraction, 133Cs MAS-NMR, and cross-sectional SEM and included glass, various zeolites, scheelite (CaWO 4) and a range of other oxide phases and Cs-containing aluminosilicate. Importantly, under no circumstance was cesium partitioned into the glass phase irrespective of whether or not the composition included the preformed Cs-containing HTB compound. For compositions containing the HTB, cesium was partitioned into one of four major phases including zeolite; Cs-silica-tungstate bronze, pollucite (CsAlSi 2O 6), and an aluminosilicate with an Al/Si ratio close to one. The leach resistance of all materials was evaluated and related to the cesium distribution within the GCC phase assemblages. In general, the GCCs prepared from the HTB had superior durability compared with materials not containing tungsten. Indeed the compositions in many cases had leach resistances comparable to the best ceramics or glass materials.

  15. Study of a novel electromagnetic liquid argon calorimeter - the TGT

    Energy Technology Data Exchange (ETDEWEB)

    Berger, C. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Braunschweig, W. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Geulig, E. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Schoentag, M. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Siedling, R. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Wlochal, M. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.; Putzer, A. [European Organization for Nuclear Research, Geneva (Switzerland); Wotschack, J. [European Organization for Nuclear Research, Geneva (Switzerland); Cheplakov, A. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Feshchenko, A. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Kazarinov, M. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Kukhtin, V. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Ladygin, E. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Obudovskij, V. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Geweniger, C. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Hanke, P. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Kluge, E.E. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Krause, J. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Schmidt, M. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Stenzel, H. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Tittel, K. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Wunsch, M. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Zerwas, D. [Heidelberg Univ. (Germany). Inst. fuer Hochenergiephysik; Bruncko, D. [Slovenska Akademia Vied, Kosice (Slovakia). Ustav Experimentalnej Fyziky; Jusko, A. [Slovenska Akademia Vied, Kosice (Slovakia). Ustav Experimentalnej Fyziky; Kocper, B.; RD33 Collaboration

    1994-11-01

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a testbeam exposure. (orig.)

  16. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    Berger, C.; Braunschweig, W.; Geulig, E.

    1994-01-01

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  17. Study of a novel electromagnetic liquid argon calorimeter - the TGT

    Energy Technology Data Exchange (ETDEWEB)

    Berger, C.; Braunschweig, W.; Geulig, E. [Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.] [and others

    1995-04-21

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a testbeam exposure. ((orig.)).

  18. Study of a novel electromagnetic liquid argon calorimeter - the TGT

    International Nuclear Information System (INIS)

    Berger, C.; Braunschweig, W.; Geulig, E.

    1995-01-01

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a testbeam exposure. ((orig.))

  19. Monte Carlo simulation of a gas-sampled hadron calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C Y; Kunori, S; Rapp, P; Talaga, R; Steinberg, P; Tylka, A J; Wang, Z M

    1988-02-15

    A prototype of the OPAL barrel hadron calorimeter, which is a gas-sampled calorimeter using plastic streamer tubes, was exposed to pions at energies between 1 and 7 GeV. The response of the detector was simulated using the CERN GEANT3 Monte Carlo program. By using the observed high energy muon signals to deduce details of the streamer formation, the Monte Carlo program was able to reproduce the observed calorimeter response. The behavior of the hadron calorimeter when placed behind a lead glass electromagnetic calorimeter was also investigated.

  20. The ATLAS Tile Calorimeter gets into shape!

    CERN Multimedia

    2002-01-01

    The last of the 64 modules for one of the ATLAS Hadron tile calorimeter barrels has just arrived at CERN. This arrival puts an end to two and a half years work assembling and testing all the modules in the Institut de Física d'Altes Energies (IFAE), in Barcelona.

  1. Upgrading the ATLAS Tile Calorimeter Electronics

    CERN Document Server

    Oreglia, M; The ATLAS collaboration

    2013-01-01

    The ATLAS detector hadron calorimeter electronics are being redesigned to address issues associated with the High Luminosity mode of LHC running in Phase-2. We describe the issues and solutions and also discuss a demonstrator unit to be installed on the detector in 2014.

  2. ATLAS: First rehearsal for the tile calorimeter

    CERN Multimedia

    2003-01-01

    The dry run assembly of the first barrel of the ATLAS tile hadron calorimeter has been successfully completed. It is now being dismantled again so that it can be lowered into the ATLAS cavern where it will be reassembled in October 2004.

  3. Pion showers in highly granular calorimeters

    Indian Academy of Sciences (India)

    New results on properties of hadron showers created by pion beam at 8–80 GeV in high granular electromagnetic and hadron calorimeters are presented. Data were used for the first time to investigate the separation of the neutral and charged hadron showers. The result is important to verify the prediction of the PFA ...

  4. Evolution of the dual-readout calorimeter

    Indian Academy of Sciences (India)

    ... a calorimeter system of a relatively simple construction and moderate costs, however with excellent properties, built upon experience gained with the extensively beam-tested DREAM (Dual REAdout. Module) prototype. The main idea of multiple readout calorimetry is to indepen- dently measure for each hadronic shower ...

  5. Performance of a uranium liquid argon calorimeter

    International Nuclear Information System (INIS)

    Tuts, P.M.

    1987-01-01

    The author presents results on the performance of a uranium and liquid argon colorimeter in the NW test beam at Fermilab. This study describes the calorimeter, and discusses its performance with electrons, pions and muons from 10 GeV to 150 GeV. The performance parameters measure response, linearity, resolution, compensation, and e/π separation

  6. SLD liquid argon calorimeter prototype test results

    International Nuclear Information System (INIS)

    Dubois, R.; Eigen, G.; Au, Y.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses

  7. Homogeneous scintillating LKr/Xe calorimeters

    International Nuclear Information System (INIS)

    Chen, M.; Mullins, M.; Pelly, D.; Shotkin, S.; Sumorok, K.; Akyuz, D.; Chen, E.; Gaudreau, M.P.J.; Bolozdynya, A.; Tchernyshev, V.; Goritchev, P.; Khovansky, V.; Koutchenkov, A.; Kovalenko, A.; Lebedenko, V.; Vinogradov, V.; Gusev, L.; Sheinkman, V.; Krasnokutsky, R.N.; Shuvalov, R.S.; Fedyakin, N.N.; Sushkov, V.; Akopyan, M.; Doke, T.; Kikuchi, J.; Hitachi, A.; Kashiwagi, T.; Masuda, K.; Shibamura, E.; Ishida, N.; Sugimoto, S.

    1993-01-01

    Recent R and D work on full length scintillating homogeneous liquid xenon/krypton (LXe/Kr) cells has established the essential properties for precision EM calorimeters: In-situ calibration using α's, radiation hardness as well as the uniformity required for δE/E≅0.5% for e/γ's above 50 GeV. (orig.)

  8. Commissioning of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Cooke, Mark S

    2009-01-01

    A selection of ATLAS liquid argon (LAr) calorimeter commissioning studies are presented. These include a coherent noise study, a measurement of the quality of the physics pulse shape prediction, and energy and time reconstruction analyses with cosmic and single beam signals.

  9. PEP-4 geiger-mode hexagonal calorimeter

    International Nuclear Information System (INIS)

    Wenzel, W.A.

    1982-01-01

    The design and performance of the calorimeter are briefly described. Design aspects include illustrations of the active volume of the detector, edge connections, module assembly and analog electronics. Performance data for cosmic rays and radiation sources, including efficiency and channel sensitivity are discussed

  10. Calibration of the ZEUS forward calorimeter

    International Nuclear Information System (INIS)

    Kraemer, M.

    1990-10-01

    The physics at the ep-collider HERA requires high resolution calorimetry calibrated with an accuracy of better than 2%. The ZEUS detector meets these conditions by means of a compensating uranium scintillator sandwich calorimeter with an energy resolution of σ/E = 35%/√E + σ cal , where σ cal is the calibration error. One of the tools to minimize σ cal is the calibration with the signals of the radioactivity of the Uranium plates (UNO). Taking UNO data every 8 hours keeps the calibration stable within ≅ 1%. The muon calibration is done employing an algorithm, that determines the most probable energy loss with a precision of ≅ 1%. The channel-to-channel fluctuations of the ratio μ/UNO for a forward calorimeter (FCAL) prototype show a spread of 5.2% for the electromagnetic calorimeter and ≅ 2.5% for the hadronic sections. Improvements in the construction of the FCAL modules decreased these fluctuations to 2.0% and ≅ 1.8% respectively. The influence of the cracks between the calorimeter modules amounts to ≅ 1.7% on average for the ZEUS geometry, if a 2 mm thick Pb-sheet is introduced between the modules. We conclude that we are able to keep σ cal below 2%. (orig.)

  11. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00223142; The ATLAS collaboration

    2016-01-01

    Many physics and performance studies with the ATLAS detector at the Large Hadron Collider require very large samples of simulated events, and producing these using the full GEANT4 detector simulation is highly CPU intensive. Often, a very detailed detector simulation is not needed, and in these cases fast simulation tools can be used to reduce the calorimeter simulation time by a few orders of magnitude. The new ATLAS Fast Calorimeter Simulation (FastCaloSim) is an improved parametrisation compared to the one used in the LHC Run-1. It provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and can be tuned to data more easily than with GEANT4. The new FastCaloSim incorporates developments in geometry and physics lists of the last five years and benefit...

  12. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00176100; The ATLAS collaboration

    2016-01-01

    The physics and performance studies of the ATLAS detector at the Large Hadron Collider re- quire a large number of simulated events. A GEANT4 based detailed simulation of the ATLAS calorimeter systems is highly CPU intensive and such resolution is often unnecessary. To reduce the calorimeter simulation time by a few orders of magnitude, fast simulation tools have been developed. The Fast Calorimeter Simulation (FastCaloSim) provides a parameterised simulation of the particle energy response at the calorimeter read-out cell level. In Run 1, about 13 billion events were simulated in ATLAS, out of which 50% were produced using fast simulation. For Run 2, a new parameterisation is being developed to improve the original version: it incorporates developments in geometry and physics lists during the last five years and benefits from the knowledge acquired from the Run 1 data. The algorithm uses machine learning techniques to improve the parameterisations and to optimise the amount of information to be stored in the...

  13. CALICE silicon-tungsten electromagnetic calorimeter

    Indian Academy of Sciences (India)

    A highly granular electromagnetic calorimeter prototype based on tungsten absorber and sampling units equipped with silicon pads as sensitive devices for signal collection is under construction. The full prototype will have in total 30 layers and be read out by about 10000 Si cells of 1 × 1 cm2. A first module consisting of 14 ...

  14. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Mlynarikova, Michaela; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter has been studied in-situ employing cosmic ray muons and a large sample of proton-proton collisions acquired during the operations of the LHC. Prompt isolated muons of high momentum fro...

  15. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Hrynevich, Aliaksei; The ATLAS collaboration

    2017-01-01

    The Tile Calorimeter (TileCal) is the central scintillator-steel sampling hadronic calorimeter of the ATLAS experiment at the LHC. Jointly with other calorimeters it is designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions. The response of high momentum isolated muons is used to study the energy response at the electromagnetic scale, isolated hadr...

  16. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Mlynarikova, Michaela; The ATLAS collaboration

    2017-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter has been studied in-situ employing cosmic ray muons and a large sample of proton-proton collisions acquired during the operations of the LHC. Prompt isolated muons of high momentum from elec...

  17. Upgrading the ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Hubacek, Zdenek; The ATLAS collaboration

    2016-01-01

    Many physics and performance studies with the ATLAS detector at the Large Hadron Collider require very large samples of simulated events, and producing these using the full GEANT4 detector simulation is highly CPU intensive. Often, a very detailed detector simulation is not needed, and in these cases fast simulation tools can be used to reduce the calorimeter simulation time by a few orders of magnitude. In ATLAS, a fast simulation of the calorimeter systems was developed, called Fast Calorimeter Simulation (FastCaloSim). It provides a parametrized simulation of the particle energy response at the calorimeter read-out cell level. It is interfaced to the standard ATLAS digitization and reconstruction software, and can be tuned to data more easily than with GEANT4. The original version of FastCaloSim has been very important in the LHC Run-1, with several billion events simulated. An improved parametrisation is being developed, to eventually address shortcomings of the original version. It incorporates developme...

  18. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Dias, Flavia; The ATLAS collaboration

    2016-01-01

    A very large number of simulated events is required for physics and performance studies with the ATLAS detector at the Large Hadron Collider. Producing these with the full GEANT4 detector simulation is highly CPU intensive. As a very detailed detector simulation is not always required, fast simulation tools have been developed to reduce the calorimeter simulation time by a few orders of magnitude. The fast simulation of ATLAS for the calorimeter systems used in Run 1, called Fast Calorimeter Simulation (FastCaloSim), provides a parameterized simulation of the particle energy response at the calorimeter read-out cell level. It is then interfaced to the ATLAS digitization and reconstruction software. In Run 1, about 13 billion events were simulated in ATLAS, out of which 50% were produced using fast simulation. For Run 2, a new parameterisation is being developed to improve the original version: It incorporates developments in geometry and physics lists of the last five years and benefits from knowledge acquire...

  19. Differential calorimeter and temperature controller for stored energy measurements in irradiated alkali halides

    International Nuclear Information System (INIS)

    Delgado Martinez, L.

    1977-01-01

    The design and performance of a simple temperature-controlled differential calorimeter are presented. This system allows to measure radiation-induced stored energy in insulators, above room temperature with a differential thermal analysis method. With platelets of KC1 single crystals, the base lines obtained for T 2 T 1 (with T 2 : irradiated sample temperature and T 1 : reference sample temperature) show a smooth drift less of 0,2 degree centigree in the interval from 25 to 400 degree centigree. The discrepancy between two consecutive base lines is less than ± 0,02 degree centigree which implies a calorimeter sensitivity of about ±0,004 cal/g. This sensitivity allows to measure stored energy release in samples with a color center concentration low enough to be directly measured with a spectrophotometer so that a search for correlations among the features of the stored energy spectrum and the color center annealing can be made. (Author) 13 refs

  20. Single crystalline LuAG fibers for homogeneous dual-readout calorimeters

    International Nuclear Information System (INIS)

    Pauwels, K; Gundacker, S; Lecoq, P; Lucchini, M; Auffray, E; Dujardin, C; Lebbou, K; Moretti, F; Xu, X; Petrosyan, A G

    2013-01-01

    For the next generation of calorimeters, designed to improve the energy resolution of hadrons and jets measurements, there is a need for highly granular detectors requiring peculiar geometries. Heavy inorganic scintillators allow compact homogeneous calorimeter designs with excellent energy resolution and dual-readout abilities. These scintillators are however not usually suited for geometries with a high aspect ratio because of the important losses observed during the light propagation. Elongated single crystals (fibers) of Lutetium Aluminium garnet (LuAG, Lu 3 Al 5 O 12 ) were successfully grown with the micropulling-down technique. We present here the results obtained with the recent fiber production and we discuss how the light propagation could be enhanced to reach attenuation lengths in the fibers better than 0.5 m

  1. The pipelined readout for the ZEUS calorimeter

    International Nuclear Information System (INIS)

    Hervas, L.

    1991-01-01

    The electron-proton storage ring complex HERA under construction at DESY in Hamburg is the first machine of a new generation of colliders. Since physics to be studied at HERA (covered in chapter 2) base on the precise measurement of kinematic variables over a very large range of energies, a foremost emphasis is set in calorimetry. After long studies and an ambitious test program, the ZEUS collaboration has built a high resolution depleted uranium-scintillator calorimeter with photomultiplier readout, the state of the art in detectors of this type. In chapter 3 the principles of calorimetry are reviewed and the construction of the ZEUS calorimeter is described. Mainly due to the large dynamic range and the short bunch crossing times a novel concept for the readout in an analog pipelined fashion had to be designed. This concept is explained in chapter 4. The solid state implementation of the pipeline required two integrated circuits which were developed specially for the ZEUS calorimeter in collaboration with an electronics research institute and produced by industry. The design and construction of these devices and the detailed testing which has been performed for properties critical in the readout is covered in chapters 5 and 6. The whole pipelined readout is a complicated setup with many steps and collaborating systems. Its implementation and the information to operate it are covered in chapter 7. Finally the concepts presented and the applications discussed have been installed and tested on a test beam calibration experiment. There, the modules of the calorimeter have been calibrated. Chapter 8 presents results from these measurements which show excellent performance of the electronics as well as optimal properties of the calorimeter modules. (orig./HSI)

  2. Solvent-Free Biginelli Condensation using Tungstate Sulfuric Acid: a Powerful and Reusable Catalyst for Selective Synthesis

    Directory of Open Access Journals (Sweden)

    Rezvan Rezaee Nasab

    2014-07-01

    Full Text Available Tungstate sulfuric acid (TSA has been prepared and used as a recyclable catalyst for the Biginelli syn-thesis of some biologically active quinazolinones/thiones under solvent-free conditions. This method has advantages such as the avoidance of organic solvents, high yield of pure products, short reaction times, and operational simplicity.  © 2014 BCREC UNDIP. All rightsReceived: 28th April 2014; Revised: 15th May 2014; Accepted: 26th May 2014[ How to Cite: Nasab, R.R., Karami, B., Khodabakhshi, S. (2014. Selective Solvent‐free Biginelli Condensation using Tungstate Sulfuric Acid as Powerful and Reusable Catalyst. Bulletin of Chemical Reaction Engineering & Catalysis, 9 (2: 142-154. (doi:10.9767/bcrec.9.2.6794.148-154][ Permalink/DOI: http://dx.doi.org/10.9767/bcrec.9.2.6794.148-154

  3. Influence of Mo impurity on the spectroscopic and scintillation properties of PbWO4 crystals

    International Nuclear Information System (INIS)

    Boehm, M.; Hofstaetter, A.; Luh, M.; Meyer, B.K.; Scharmann, A.; Drobychev, G.Yu.; Grenoble-1 Univ., 74 - Annecy; Peigneux, J.P.

    1997-12-01

    The influence of molybdenum doping on the spectroscopic and scintillation properties of lead tungstate crystals has been investigated. From the results the slow scintillation component as well as the afterglow are found to be due to the Mo impurity. In addition the blue luminescence from excited (WO 4 ) 2- -complex seems to be increasingly suppressed as the doping concentration goes on. Possible mechanisms for the effects have been discussed. (author)

  4. High resolution crystal calorimetry at LHC

    International Nuclear Information System (INIS)

    Schneegans, M.; Ferrere, D.; Lebeau, M.; Vivargent, M.

    1991-01-01

    The search for Higgs bosons above Lep200 reach could be one of the main tasks of the future pp and ee colliders. In the intermediate mass region, and in particular in the range 80-140 GeV/c 2 , only the 2-photon decay mode of a Higgs produced inclusively or in association with a W, gives a good chance of observation. A 'dedicated' very high resolution calorimeter with photon angle reconstruction and pion identification capability should detect a Higgs signal with high probability. A crystal calorimeter can be considered as a conservative approach to such a detector, since a large design and operation experience already exists. The extensive R and D needed for finding a dense, fast and radiation hard crystal, is under way. Guide-lines for designing an optimum calorimeter for LHC are discussed and preliminary configurations are given. (author) 7 refs., 3 figs., 2 tabs

  5. The design of the data acquisition system for a very large bismuth germanate calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, J.; Isaila, M.; Piroue, P.; Stickland, D.; Sumner, R.

    1984-02-01

    LEPC, the Large Electron Positron Collider being built at CERN, will be ready for experiments in 1988. A large array of bismuth germanate crystals will be part of one of the first experiments to be installed. Particles (including photons) resulting from the collisions will be identified and measured in the surrounding detector. At the center of this composite detector is a tracking device to observe the trajectories of all particles. Beyond this is the bismuth germanate array; it will measure the energy of electrons and photons from a few MeV to 100 GeV. This is surrounded by the hadron calorimeter. The bismuth germanate calorimeter will consist of about 12,000 individual bismuth germanate crystals. Each crystal will have an independent readout system. This system uses silicon photodiodes, each with its own ADC, to measure the scintillation light from each crystal. The ADC is implemented in software in a single chip microcomputer, using a modification of successive approximation, which produces a very wide dynamic range. The microcomputer also provides data buffering and several other housekeeping functions. The initial design of the readout system, presented in this paper, evolved from an attempt to minimize the size requirements and the number of cables needed, and to meet the dynamic range requirement in a practical way.

  6. The design of the data acquisition system for a very large bismuth germanate calorimeter

    International Nuclear Information System (INIS)

    Bakken, J.; Isaila, M.; Piroue, P.; Stickland, D.; Sumner, R.

    1984-01-01

    LEPC, the Large Electron Positron Collider being built at CERN, will be ready for experiments in 1988. A large array of bismuth germanate crystals will be part of one of the first experiments to be installed. Particles (including photons) resulting from the collisions will be identified and measured in the surrounding detector. At the center of this composite detector is a tracking device to observe the trajectories of all particles. Beyond this is the bismuth germanate array; it will measure the energy of electrons and photons from a few MeV to 100 GeV. This is surrounded by the hadron calorimeter. The bismuth germanate calorimeter will consist of about 12,000 individual bismuth germanate crystals. Each crystal will have an independent readout system. This system uses silicon photodiodes, each with its own ADC, to measure the scintillation light from each crystal. The ADC is implemented in software in a single chip microcomputer, using a modification of successive approximation, which produces a very wide dynamic range. The microcomputer also provides data buffering and several other housekeeping functions. The initial design of the readout system, presented in this paper, evolved from an attempt to minimize the size requirements and the number of cables needed, and to meet the dynamic range requirement in a practical way

  7. Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Auffray, Etiennette; Baccaro, Stefania; Baffioni, Stephanie; Baillon, Paul; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Berthon, Ursula; Betev, Botjo; Beuselinck, Raymond; Bhardwaj, Ashutosh; Bialas, Wojciech; Biino, Cristina; Bimbot, Stephane; Blaha, Jan; Bloch, Philippe; Blyth, Simon; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton, David; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Cerutti, Muriel; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chatterji, Sudeep; Chen, E Augustine; Chipaux, Rémi; Choudhary, Brajesh C; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Cossutti, Fabio; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; Decotigny, David; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Del Re, Daniele; Della Negra, Rodolphe; Della Ricca, Giuseppe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Golutvin, Igor; Gómez-Reino, Robert; Govoni, Pietro; Grahl, James; Gras, Philippe; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel De Montechenault, G; Hansen, Magnus; Heath, Helen F; Hill, Jack; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Jarry, Patrick; Jauffret, C; Jha, Manoj; Karar, M A; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Litvin, V; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Luckey, D; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Malberti, Martina; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Mathieu, Antoine; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman, Harvey B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rahatlou, Shahram; Rander, John; Ranjan, Kirti; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rumerio, Paolo; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Seez, Christopher; Semeniouk, Igor; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Y; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Timlin, Claire; Triantis, F A; Troshin, Sergey; Tyurin, Nikolay; Ueno, Koji; Uzunian, Andrey; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Vigano, S; Viertel, Gert; Virdee, Tejinder; Vlassov, E; Wang, Minzu; Weinstein, Alan; Williams, Jennifer C; Yaselli, Ignacio; Zabi, Alexandre; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhang, Jia-Wen; Zhang, Yawei; Zhu, Kejun; Zhu, Ren-Yuan

    2007-01-01

    The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by summing the energy measured in arrays of 3x3 or 5x5 channels. There was no significant amount of correlated noise observed within these arrays. For electrons incident at the centre of the studied 3x3 arrays of crystals, the mean stochastic term was measured to be 2.8% and the mean constant term to be 0.3%. The amount of the incident electron's energy which is contained within the array depends on its position of incidence. The variation of the containment with position is corrected for using the distribution of the measured energy within the array. For uniform illumination of a crystal with 120 GeV electrons a resolution of 0.5% was achieved. The energy resolution meets the design goal for the detector.

  8. X-Ray Calorimeter Arrays for Astrophysics

    Science.gov (United States)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  9. The roles of phosphate and tungstate species in surface acidities of TiO2-ZrO2 binary oxides - A comparison study

    Science.gov (United States)

    Chaudhary, Manchal; Shen, Po-fan; Chang, Sue-min

    2018-05-01

    Porous tungstated and phosphated TiO2-ZrO2 (TZ) binary oxides with high and strong acidity were successfully prepared by means of sol-gel or impregnation approaches. In addition, the influences of the two types of modifiers on the microstructures and acidity were systematically examined, compared, and clarified. The TZ oxide derived from a surfactant-templating method exhibited a high surface area of 195 m2/g with a pore size of 6.3 nm. Moreover, it had a high acidity of 859 μmol/g with a density of 4.4 μmol/nm2 because of defective surface. Phosphation significantly increased the acidity to 1547 μmol/g and showed the highest acid density of 6.7 μmol/nm2 at a surface P density of 22.7P/nm2. On the other hand, tungstated compounds just showed the highest acidity of 972 μmol/g and the highest acid density of 4.8 μmol/nm2 at 4.7 W/nm2. Compared to tungstate species, phosphate anions are more capable of promoting the acidity because they are able to distort the host network and inhibit elemental rearrangement. While Lewis acidity prevailed in the tungstated compounds, Brønsted acidity was dominant in the phosphated oxides. The Wdbnd O and Psbnd OH groups were responsible for strong acidity in the modified compounds. Phosphated compounds formed strong Brønsted acid sites on the Psbnd OH groups with a particular strength, and tungstation produced Lewis acid sites with a continuous strength on the metal ions adjacent to the tungstate moieties. Cyclic NH3 adsorption-desorption processes revealed that the active sites for NH3 adsorption were stable in both the tungstate and phosphate modified compounds, revealing that these solid acids are promising as the adsorbents for removal of base gases.

  10. Radiation Damage in Scintillating Crystals

    CERN Document Server

    Zhu Ren Yuan

    1998-01-01

    Crystal Calorimetry in future high energy physics experiments faces a new challenge to maintain its precision in a hostile radiation environment. This paper discusses the effects of radiation damage in scintillating crystals, and concludes that the predominant radiation damage effect in crystal scintillators is the radiation induced absorption, or color center formation, not the loss of the scintillation light yield. The importance of maintaining crystal's light response uniformity and the feasibility to build a precision crystal calorimeter under radiation are elaborated. The mechanism of the radiation damage in scintillating crystals is also discussed. While the damage in alkali halides is found to be caused by the oxygen or hydroxyl contamination, it is the structure defects, such as oxygen vacancies, cause damage in oxides. Material analysis methods used to reach these conclusions are presented in details.

  11. Large-scale production of PWO scintillation elements for CMS ECAL

    International Nuclear Information System (INIS)

    Annenkov, A.; Auffray, E.; Drobychev, G.; Korzhik, M.; Kostylev, V.; Kovalev, O.; Lecoq, P.; Ligoun, V.; Missevitch, O.; Zouevski, R.

    2005-01-01

    JSC Bogoroditsk Technical Chemical Plant, BTCP, has produced up to date more than 20,000 lead tungstate scintillation elements for the electromagnetic calorimeter of CMS Collaboration. Here we report on the status of the crystal production and results of the quality insurance program, which is performed by the Collaboration in cooperation with BTCP to keep crystal properties within specifications

  12. Tungsten Trioxide/Zinc Tungstate Bilayers: Electrochromic Behaviors, Energy Storage and Electron Transfer

    International Nuclear Information System (INIS)

    Wei, Huige; Ding, Daowei; Yan, Xingru; Guo, Jiang; Shao, Lu; Chen, Haoran; Sun, Luyi; Colorado, Henry A.; Wei, Suying; Guo, Zhanhu

    2014-01-01

    Highlights: • Tungsten oxide and zinc tungstate bilayers have been prepared via a facile sol-gel method for integrated applications of electrochromic behaviors and energy storage;. • Electron transfer behaviors between the semiconductor bilayer films have been found dependent on the bilayer assembly sequence;. • Methylene blue (MB) has been employed for the first time as an indicator to study the electron transfer phenomenon in the bilayer films. - Abstract: Pair-sequentially spin-coated tungsten trioxide (WO 3 ) and zinc tungstate (ZnWO 4 ) bilayer films onto indium tin oxide (ITO) coated glass slides have been prepared via sol-gel methods followed by annealing. The bilayers (ZnWO 4 /WO 3 denoting the bilayer film with the inner layer of ZnWO 4 and the outer layer of WO 3 on the ITO while WO 3 /ZnWO 4 standing for the bilayer film with the inner layer of WO 3 and the outer layer of ZnWO 4 on the ITO) exhibit integrated functions of electrochromic and energy storage behaviors as indicated by the in situ spectroelectrochemistry and cyclic voltammetry (CV) results. Accordingly, blue color was observed for the bilayer films at -1 V in 0.5 M H 2 SO 4 solution. An areal capacitance of 140 and 230 μF/cm 2 was obtained for the ZnWO 4 /WO 3 , and WO 3 /ZnWO 4 film, respectively, at a scan rate of 0.05 V/s in the CV measurements. The CV results also unveiled the electron transfer behavior between the semiconductor films in the oxidation process, suggesting a sequence-dependent electrochemical response in the bilayer films. Meanwhile, methylene blue (MB) was used as an indicator to study the electron transfer phenomenon during the reduction process at negative potentials of -0.4 and -0.8 V, in 0.5 M Na 2 SO 4 . The results indicated that the electrons transfer across the bilayers was enhanced at more negative potentials

  13. Sources of compensation in hadronic calorimeters

    International Nuclear Information System (INIS)

    Goodman, M.S.; Gabriel, T.A.; Di Ciaccio, A.; Wilson, R.

    1988-12-01

    Monte Carlo simulations are presented using the CALOR code system to study the design of a large hybrid hadron calorimeter system employing a warm liquid active medium (tetramethylsilane, Si(CH 3 ) 4 ) and uranium plates in addition to a conventional Fe/plastic system. In the system described here, the uranium provides partial compensation by suppressing the electromagnetic cascade produced by incident electrons due to sampling inefficiencies. The results of the simulations also indicate that significant compensation is achieved (given small enough saturation) due to low energy recoil protons produced in collisions with low energy (1--20 MeV) cascade and fission neutrons in the active medium. Both compensation mechanisms are important to help balance the response of a calorimeter to incident electrons and hadrons, that is, to achieve a ratio of pulse heights (e/h ∼ 1) which will lead to the best energy resolution. 17 refs., 4 figs., 2 tabs

  14. Precision timing with liquid ionization calorimeters

    International Nuclear Information System (INIS)

    Benary, O.; Cannon, S.; Cleland, W.; Ferguson, I.; Finley, C.; Gordeev, A.; Gordon, H.; Kistenev, E.; Kroon, P.; Letchouk, M.; Lissauer, D.; Ma, H.; Makowiecki, D.; Maslennikov, A.; McCorkle, S.; Onoprienko, D.; Onuchin, A.; Oren, Y.; Panin, V.; Parsons, J.; Rabel, J.; Radeka, V.; Rogers, L.; Rahm, D.; Rescia, S.; Rutherfoord, J.; Seman, M.; Smith, M.; Sondericker, J. III; Steiner, R.; Stephani, D.; Stern, E.; Stumer, I.; Takai, H.; Themann, H.; Tikhonov, Y.

    1993-01-01

    We present timing measurements performed with a liquid krypton electromagnetic accordion calorimeter, measured in an electron beam over an energy range of 5-20 GeV. A novel discriminator with an amplitude-independent timing response was used to extract the inherently accurate timing information from the calorimeter. As expected, the timing resolution σ τ is observed to vary inversely with the signal amplitude, which is proportional to the deposited energy E. We measure a resolution of σ τ =4.15±0.06 GeV ns/E for a sum of 5x5 towers with dimensions 2.7x2.5 cm 2 each. From this we deduce that the timing resolution for an individual tower is approximately 0.8 GeV ns/E. (orig.)

  15. Work on a ATLAS tile calorimeter Barrel

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    The Tile Calorimeter is designed as one barrel and two extended barrel hadron parts. The calorimeter consists of a cylindrical structure with inner and outer radius of 2280 and 4230 mm respectively. The barrel part is 5640 mm in length along the beam axis, while each of the extended barrel cylinders is 2910 mm long. Each detector cylinder is built of 64 independent wedges along the azimuthal direction. Between the barrel and the extended barrels there is a gap of about 600 mm, which is needed for the Inner Detector and the Liquid Argon cables, electronics and services. The barrel covers the region -1.0

  16. The ATLAS Tile Calorimeter Performance at LHC

    CERN Document Server

    Molander, S; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment at LHC. The TileCal pays a major role in detecting hadrons, jets, hadronic decays of tau leptons and measuring the missing transverse energy. Due to the very good signal to noise ratio it assists the muon spectrometer in the identification and reconstruction of muons, which are also a tool for the in situ energy scale validation. The results presented here stem from the data collection in dedicated calibration runs, in cosmic rays data-taking and in LHC collisions along 3 years of operation. The uniformity, stability and precision of the energy scale, the time measurement capabilities and the robustness of the performance against pile-up are exposed through the usage of hadronic and muon final states and confirm the design expectations.

  17. LHCb: Upgrade of the LHCb calorimeter electronics

    CERN Multimedia

    Mauricio Ferre, J

    2013-01-01

    The LHCb collaboration foresees a major upgrade of the detector for the high luminosity run that should take place after 2018. Apart from the increase of the instantaneous luminosity at the interaction point of the experiment, one of the major ingredients of this upgrade is a full readout at 40MHz of the sub-detectors and the acquisition of the data by a large farm of PC. The trigger will be done by this farm and should increase the overall trigger efficiency with respect to the current detector, especially in hadronic B meson decays. A general overview of the modifications foreseen to the calorimeter system and the integration of the electromagnetic and hadronic calorimeters in this new scheme will be described.

  18. Hermeticity of three cryogenic calorimeter geometries

    International Nuclear Information System (INIS)

    Strovink, M.; Wormersley, W.J.; Forden, G.E.

    1989-04-01

    We calculate the effect of cracks and dead material on resolution in three simplified cryogenic calorimeter geometries, using a crude approximation that neglects transverse shower spreading and considers only a small set of incident angles. For each dead region, we estimate the average unseen energy using a shower parametrization, and relate it to resolution broadening using a simple approximation that agrees with experimental data. Making reasonable and consistent assumptions on cryostat wall thicknesses, we find that the effects of cracks and dead material dominate the expected resolution in the region where separate ''barrel'' and ''end'' cryostats meet. This is particularly true for one geometry in which the end calorimeter caps the barrel and also protrudes into the hole within it. We also find that carefully designed auxiliary ''crack filler'' detectors can substantially reduce the loss of resolution in these areas. 6 figs

  19. The ATLAS Electromagnetic Calorimeter Calibration Workshop

    CERN Multimedia

    Hong Ma; Isabelle Wingerter

    The ATLAS Electromagnetic Calorimeter Calibration Workshop took place at LAPP-Annecy from the 1st to the 3rd of October; 45 people attended the workshop. A detailed program was setup before the workshop. The agenda was organised around very focused presentations where questions were raised to allow arguments to be exchanged and answers to be proposed. The main topics were: Electronics calibration Handling of problematic channels Cluster level corrections for electrons and photons Absolute energy scale Streams for calibration samples Calibration constants processing Learning from commissioning Forty-five people attended the workshop. The workshop was on the whole lively and fruitful. Based on years of experience with test beam analysis and Monte Carlo simulation, and the recent operation of the detector in the commissioning, the methods to calibrate the electromagnetic calorimeter are well known. Some of the procedures are being exercised in the commisssioning, which have demonstrated the c...

  20. Instrumented module of the ATLAS tile calorimeter

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    The ATLAS tile calorimeter consists of steel absorber plates interspersed with plastic scintillator tiles. Interactions of high-energy hadrons in the plates transform the incident energy into a 'hadronic shower'. When shower particles traverse the scintillating tiles, the latter emit an amount of light proportional to the incident energy. This light is transmitted along readout fibres to a photomultiplier, where a detectable electrical signal is produced. These pictures show one of 64 modules or 'wedges' of the barrel part of the tile calorimeter, which are arranged to form a cylinder around the beam axis. The wedge has been instrumented with scintillators and readout fibres. Photos 03, 06: Checking the routing of the readout fibres into the girder that houses the photomultipliers. Photo 04: A view of the fibre bundles inside the girder.

  1. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Jacka, Petr; The ATLAS collaboration

    2018-01-01

    With the huge amount of data collected with ATLAS, there is a need to produce a large number of simulated events. These productions are very CPU and time consuming when using the full GEANT4 simulation. FastCaloSim is a program to quickly simulate the ATLAS calorimeter response, based on a parameterization of the GEANT4 energy deposits of several kinds of particles in a grid of energy and eta. A new version of FastCaloSim is under development and its integration into the ATLAS simulation infrastructure is ongoing. The use of machine learning techniques improves the performance and decreases the memory usage. Dedicated parameterizations for the forward calorimeters are being studied. First results of the new FastCaloSim show substantial improvements of the description of energy and shower shape variables, including the variables for jet substructure.

  2. The dry heat exchanger calorimeter system

    International Nuclear Information System (INIS)

    Renz, D.P.; Wetzel, J.R.; James, S.J.; Kasperski, P.W.; Duff, M.F.

    1991-01-01

    A radiometric isothermal heat flow calorimeter and preconditioner system that uses air instead of water as the heat exchange medium has been developed at Mound. The dry heat exchanger calorimeter is 42 inches high by 18 inches in diameter and the preconditioner is a 22 inch cube, making it extremely compact compared to existing units. The new system is ideally suited for transportable, stand-alone, or glovebox applications. Preliminary tests of the system have produced sample measurements with standard deviations less than 0.25% and sample errors less than 0.50%. These tests have shown that the dry heat exchanger system will yield acceptance data with an accuracy comparable to those of Mound water bath systems now in use. 4 figs., 1 tab

  3. Muon Detection Based on a Hadronic Calorimeter

    CERN Document Server

    Ciodaro, T; Abreu, R; Achenbach, R; Adragna, P; Aharrouche, M; Aielli, G; Al-Shabibi, A; Aleksandrov, I; Alexandrov, E; Aloisio, A; Alviggi, M G; Amorim, A; Amram, N; Andrei, V; Anduaga, X; Angelaszek, D; Anjos, N; Annovi, A; Antonelli, S; Anulli, F; Apolle, R; Aracena, I; Ask, S; Åsman, B; Avolio, G; Baak, M; Backes, M; Backlund, S; Badescu, E; Baines, J; Ballestrero, S; Banerjee, S; Bansil, H S; Barnett, B M; Bartoldus, R; Bartsch, V; Batraneanu, S; Battaglia, A; Bauss, B; Beauchemin, P; Beck, H P; Bee, C; Begel, M; Behera, P K; Bell, P; Bell, W H; Bellagamba, L; Bellomo, M; Ben Ami, S; Bendel, M; Benhammou, Y; Benslama, K; Berge, D; Bernius, C; Berry, T; Bianco, M; Biglietti, M; Blair, R E; Bogaerts, A; Bohm, C; Boisvert, V; Bold, T; Bondioli, M; Borer, C; Boscherini, D; Bosman, M; Bossini, E; Boveia, A; Bracinik, J; Brandt, A G; Brawn, I P; Brelier, B; Brenner, R; Bressler, S; Brock, R; Brooks, W K; Brown, G; Brunet, S; Bruni, A; Bruni, G; Bucci, F; Buda, S; Burckhart-Chromek, D; Buscher, V; Buttinger, W; Calvet, S; Camarri, P; Campanelli, M; Canale, V; Canelli, F; Capasso, L; Caprini, M; Caracinha, D; Caramarcu, C; Cardarelli, R; Carlino, G; Casadei, D; Casado, M P; Cattani, G; Cerri, A; Cerrito, L; Chapleau, B; Childers, J T; Chiodini, G; Christidi, I; Ciapetti, G; Cimino, D; Ciobotaru, M; Coccaro, A; Cogan, J; Collins, N J; Conde Muino, P; Conidi, C; Conventi, F; Corradi, M; Corso-Radu, A; Coura Torres, R; Cranmer, K; Crescioli, F; Crone, G; Crupi, R; Cuenca Almenar, C; Cummings, J T; Curtis, C J; Czyczula, Z; Dam, M; Damazio, D; Dao, V; Darlea, G L; Davis, A O; De Asmundis, R; De Pedis, D; De Santo, A; de Seixas, J M; Degenhardt, J; Della Pietra, M; Della Volpe, D; Demers, S; Demirkoz, B; Di Ciaccio, A; Di Mattia, A; Di Nardo, R; Di Simone, A; Diaz, M A; Dietzsch, T A; Dionisi, C; Dobson, E; Dobson, M; dos Anjos, A; Dotti, A; Dova, M T; Drake, G; Dufour, M-A; Dumitru, I; Eckweiler, S; Ehrenfeld, W; Eifert, T; Eisenhandler, E; Ellis, K V; Ellis, N; Emeliyanov, D; Enoque Ferreira de Lima, D; Ermoline, Y; Ernst, J; Etzion, E; Falciano, S; Farrington, S; Farthouat, P; Faulkner , P J W; Fedorko, W; Fellmann, D; Feng, E; Ferrag, S; Ferrari, R; Ferrer, M L; Fiorini, L; Fischer, G; Flowerdew, M J; Fonseca Martin, T; Francis, D; Fratina, S; French, S T; Front, D; Fukunaga, C; Gadomski, S; Garelli, N; Garitaonandia Elejabarrieta, H; Gaudio, G; Gee, C N P; George, S; Giagu, S; Giannetti, P; Gillman, A R; Giorgi, M; Giunta, M; Giusti, P; Goebel, M; Gonçalo, R; Gonzalez Silva, L; Göringer, C; Gorini, B; Gorini, E; Grabowska-Bold, I; Green, B; Groll, M; Guida, A; Guler, H; Haas, S; Hadavand, H; Hadley, D R; Haller, J; Hamilton, A; Hanke, P; Hansen, J R; Hasegawa, S; Hasegawa, Y; Hauser, R; Hayakawa, T; Hayden, D; Head, S; Heim, S; Hellman, S; Henke, M; Hershenhorn, A; Hidvégi, A; Hillert, S; Hillier, S J; Hirayama, S; Hod, N; Hoffmann, D; Hong, T M; Hryn'ova, T; Huston, J; Iacobucci, G; Igonkina, O; Ikeno, M; Ilchenko, Y; Ishikawa, A; Ishino, M; Iwasaki, H; Izzo, V; Jez, P; Jimenez Otero, S; Johansen, M; Johns, K; Jones, G; Joos, M; Kadlecik, P; Kajomovitz, E; Kanaya, N; Kanega, F; Kanno, T; Kapliy, A; Kaushik, V; Kawagoe, K; Kawamoto, T; Kazarov, A; Kehoe, R; Kessoku, K; Khomich, A; Khoriauli, G; Kieft, G; Kirk, J; Klemetti, M; Klofver, P; Klous, S; Kluge, E-E; Kobayashi, T; Koeneke, K; Koletsou, I; Koll, J D; Kolos, S; Kono, T; Konoplich, R; Konstantinidis, N; Korcyl, K; Kordas, K; Kotov, V; Kowalewski, R V; Krasznahorkay, A; Kraus, J; Kreisel, A; Kubota, T; Kugel, A; Kunkle, J; Kurashige, H; Kuze, M; Kwee, R; Laforge, B; Landon, M; Lane, J; Lankford, A J; Laranjeira Lima, S M; Larner, A; Leahu, L; Lehmann Miotto, G; Lei, X; Lellouch, D; Levinson, L; Li, S; Liberti, B; Lilley, J N; Linnemann, J T; Lipeles, E; Lohse, T; Losada, M; Lowe, A; Luci, C; Luminari, L; Lundberg, J; Lupu, N; Machado Miguéns, J; Mackeprang, R; Maettig, S; Magnoni, L; Maiani, C; Maltrana, D; Mangeard, P-S; Männer, R; Mapelli, L; Marchese, F; Marino, C; Martin, B; Martin, B T; Martin, T; Martyniuk, A; Marzano, F; Masik, J; Mastrandrea, P; Matsushita, T; McCarn, A; Mechnich, J; Medinnis, M; Meier, K; Melachrinos, C; Mendoza Nava, L M; Merola, L; Messina, A; Meyer, C P; Middleton, R P; Mikenberg, G; Mills, C M; Mincer, A; Mineev, M; Misiejuk, A; Moa, T; Moenig, K; Monk, J; Monticelli, F; Mora Herrera, C; Morettini, P; Morris, J D; Müller, F; Munwes, Y; Murillo Garcia, R; Nagano, K; Nagasaka, Y; Navarro, G A; Negri, A; Nelson, S; Nemethy, P; Neubauer, M S; Neusiedl, A; Newman, P; Nisati, A; Nomoto, H; Nozaki, M; Nozicka, M; Nurse, E; Ochando, C; Ochi, A; Oda, S; Oh, A; Ohm, C; Okumura, Y; Olivito, D; Omachi, C; Osculati, B; Oshita, H; Ospanov, R; Owen, M A; Özcan, V E; Ozone, K; Padilla, C; Panes, B; Panikashvili, N; Paramonov, A; Parodi, F; Pasqualucci, E; Pastore, F; Patricelli, S; Pauly, T; Perera, V J O; Perez, E; Petcu, M; Petersen, B A; Petersen, J; Petrolo, E; Phan, A; Piegaia, R; Pilkington, A; Pinder, A; Poddar, S; Polini, A; Pope, B G; Potter, C T; Primavera, M; Prokoshin, F; Ptacek, E; Qian, W; Quinonez, F; Rajagopalan, S; Ramos Dos Santos Neves, R; Reinherz-Aronis, E; Reinsch, A; Renkel, P; Rescigno, M; Rieke, S; Riu, I; Robertson, S H; Robinson, M; Rodriguez, D; Roich, A; Romeo, G; Romero, R; Roos, L; Ruiz Martinez, A; Ryabov, Y; Ryan, P; Saavedra, A; Safai Tehrani, F; Sakamoto, H; Salamanna, G; Salamon, A; Saland, J; Salnikov, A; Salvatore, F; Sankey, D P C; Santamarina, C; Santonico, R; Sarkisyan-Grinbaum, E; Sasaki, O; Savu, D; Scannicchio, D A; Schäfer, U; Scharf, V L; Scheirich, D; Schiavi, C; Schlereth, J; Schmitt, K; Schroder, C; Schroer, N; Schultz-Coulon, H-C; Schwienhorst, R; Sekhniaidze, G; Sfyrla, A; Shamim, M; Sherman, D; Shimojima, M; Shochet, M; Shooltz, D; Sidoti, A; Silbert, O; Silverstein, S; Sinev, N; Siragusa, G; Sivoklokov, S; Sjoen, R; Sjölin, J; Slagle, K; Sloper, J E; Smith, B C; Soffer, A; Soloviev, I; Spagnolo, S; Spiwoks, R; Staley, R J; Stamen, R; Stancu, S; Steinberg, P; Stelzer, J; Stockton, M C; Straessner, A; Strauss, E A; Strom, D; Su, D; Sugaya, Y; Sugimoto, T; Sushkov, S; Sutton, M R; Suzuki, Y; Taffard, A; Taiblum, N; Takahashi, Y; Takeda, H; Takeshita, T; Tamsett, M; Tan, C L A; Tanaka, S; Tapprogge, S; Tarem, S; Tarem, Z; Taylor, C; Teixeira-Dias, P; Thomas, J P; Thompson, P D; Thomson, M A; Tokushuku, K; Tollefson, K; Tomoto, M; Topfel, C; Torrence, E; Touchard, F; Traynor, D; Tremblet, L; Tricoli, A; Tripiana, M; Triplett, N; True, P; Tsiakiris, M; Tsuno, S; Tuggle, J; Ünel, G; Urquijo, P; Urrejola, P; Usai, G; Vachon, B; Vallecorsa, S; Valsan, L; Vandelli, W; Vari, R; Vaz Gil Lopes, L; Veneziano, S; Ventura, A; Venturi, N; Vercesi, V; Vermeulen, J C; Volpi, G; Vorwerk, V; Wagner, P; Wang, M; Warburton, A; Watkins, P M; Watson, A T; Watson, M; Weber, P; Weidberg, A R; Wengler, T; Werner, P; Werth, M; Wessels, M; White, M; Whiteson, D; Wickens, F J; Wiedenmann, W; Wielers, M; Winklmeier, F; Woods, K S; Wu, S-L; Wu, X; Xaplanteris Karampatsos, L; Xella, S; Yakovlev, A; Yamazaki, Y; Yang, U; Yasu, Y; Yuan, L; Zaitsev, A; Zanello, L; Zhang, H; Zhang, J; Zhao, L; Zobernig, H; zur Nedden, M

    2010-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. The information from TileCal's last segmentation layer can assist in muon tagging and it is being considered for a near future upgrade of the level-one trigger, mainly for rejecting triggers due to cavern background at the barrel region. A muon receiver for the TileCal muon signals is being designed in order to interface with the ATLAS level-one trigger. This paper addresses the preliminary studies concerning the muon discrimination capability for the muon receiver. Monte Carlo simulations for single muons from the interaction point were used to study the effectiveness of hadronic calorimeter information on muon detection.

  4. Upgrading the ATLAS Tile Calorimeter Electronics

    Directory of Open Access Journals (Sweden)

    Carrió Fernando

    2013-11-01

    Full Text Available This work summarizes the status of the on-detector and off-detector electronics developments for the Phase 2 Upgrade of the ATLAS Tile Calorimeter at the LHC scheduled around 2022. A demonstrator prototype for a slice of the calorimeter including most of the new electronics is planned to be installed in ATLAS in the middle of 2014 during the first Long Shutdown. For the on-detector readout, three different front-end boards (FEB alternatives are being studied: a new version of the 3-in-1 card, the QIE chip and a dedicated ASIC called FATALIC. The Main Board will provide communication and control to the FEBs and the Daughter Board will transmit the digitized data to the off-detector electronics in the counting room, where the super Read-Out Driver (sROD will perform processing tasks on them and will be the interface to the trigger levels 0, 1 and 2.

  5. Upgrade of the ATLAS Tile Calorimeter Electronics

    CERN Document Server

    Carrio, F; The ATLAS collaboration

    2014-01-01

    This presentation summarizes the status of the on-detector and off-detector electronics developments for the Phase II Upgrade of the ATLAS Tile Calorimeter at the LHC scheduled around 2024. A demonstrator prototype for a slice of the calorimeter including most of the new electronics is planned to be installed in ATLAS in middle 2014 during the Long Shutdown. For the on-detector readout, three different front-end boards (FEB) alternatives are being studied: a new version of the 3-in-1 card, the QIE chip and a dedicated ASIC called FATALIC. The MainBoard will provide communication and control to the FEBs and the DaughterBoard will transmit the digitized data to the off-detector electronics in the counting room, where the sROD will perform processing tasks on them.

  6. Upgrading the ATLAS Tile Calorimeter Electronics

    CERN Document Server

    Carrio, F

    2013-01-01

    This work summarizes the status of the on-detector and off-detector electronics developments for the Phase II Upgrade of the ATLAS Tile Calorimeter at the LHC scheduled around 2022. A demonstrator prototype for a slice of the calorimeter including most of the new electronics is planned to be installed in ATLAS in middle 2014 during the Long Shutdown. For the on-detector readout, three different front-end boards (FEB) alternatives are being studied: a new version of the 3-in-1 card, the QIE chip and a dedicated ASIC called FATALIC. The MainBoard will provide communication and control to the FEBs and the DaughterBoard will transmit the digitized data to the off-detector electronics in the counting room, where the sROD will perform processing tasks on them.

  7. Measurements with the Chalk River Calorimeters

    International Nuclear Information System (INIS)

    Boyd, A.W.

    1970-01-01

    The Chalk River calorimeters were designed to measure the absorbed dose rate in reactors in materials such as graphite, polyethylene and beryllium in the range 0.01-1 Wg -1 . To eliminate heaters in the sample they were made to operate adiabatically, or more accurately quasi-adiabatically since there is no heater on the jacket. Both the sample and jacket temperatures are recorded from the time of insertion in the reactor flux and the absorbed dose rate is calculated from these data. The advantages of this type of calorimeter are the ease of construction and the absence of a sample heater. The disadvantage is that dose rates below ~ 10 mWg -1 cannot be determined accurately

  8. The new UA1 calorimeter trigger

    International Nuclear Information System (INIS)

    Eisenhandler, E.

    1988-01-01

    The new UA1 first-level calorimeter trigger processor is described, with emphasis on the fast two-dimensional electromagnetic cluster-finding that is its most novel feature. This processor is about five times more powerful than its predecessor, and makes extensive use of pipelining techniques. It allows multiple combinations of triggers on electromagnetic showers, hadronic jets and energy sums, including a total-energy veto of multiple interactions and a full vector sum of missing transverse energy. (author)

  9. The ZEUS second level calorimeter trigger

    International Nuclear Information System (INIS)

    Jong, S.J. de.

    1990-01-01

    ZEUS is a detector for the HERA ep collider, consisting of several large components. The most important being the inner tracking detectors, which are positioned nearest to the interaction point, the calorimeter surrounding the inner tracking detectors and the muon detectors on the outside of the experimental setup. Each component will deliver a vast amount of information. In order to keep this information manageable, data is preprocessed and condensed per component and then combined to obtain the final global trigger result. The main subject of this thesis is the second level calorimeter trigger processor of the ZEUS detector. In order to be able to reject the unwanted events passing the first level, the topological event signature will have to be used at the second level. The most demanding task of the second level is the recognition of local energy depositions corresponding to isolated electrons and hadron jets. Also part of the work performed by the first level will be repeated with a higher level of accuracy. Additional information not available to the first level trigger will be processed and will be made available to the global second level trigger decision module. For the second level calorimeter trigger processor a special VME module, containing two transputers, has been developed. The second level calorimeter trigger algorithm described in this thesis was tested with simulated events, that were tracked through a computer simulation of the ZEUS detector. A part of this thesis is therefore devoted to the description of the various Monte Carlo models and the justification of the way in which they were used. (author). 132 refs.; 76 figs.; 18 tabs

  10. Isothermal calorimeter for reactor radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Radak, B; Markovic, V [Institute of Nuclear Sciences Boris Kidric, Odeljenje za radijacionu hemiju, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    An isothermal calorimeter with thermistors for measuring absorbed dose rates from 10{sup 4}-5-6.10{sup 5} rad/h in reactor experimental holes has been designed. A kinetics method for determining the equilibrium temperature difference has been developed, and its application in isothermal calorimetry proved. The expected accuracy in measurements within {+-} 2-5% has been proved by measurements carried out in the reactor. Some data obtained by measurements in the reactor RA are presented (author)

  11. Homogeneous scintillating LKr/Xe calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M.; Mullins, M.; Pelly, D.; Shotkin, S.; Sumorok, K. (Lab. for Nuclear Science, MIT, Cambridge, MA (United States)); Akyuz, D.; Chen, E.; Gaudreau, M.P.J. (Plasma Fusion Center, MIT, Cambridge, MA (United States)); Bolozdynya, A.; Tchernyshev, V.; Goritchev, P.; Khovansky, V.; Koutchenkov, A.; Kovalenko, A.; Lebedenko, V.; Vinogradov, V.; Gusev, L.; Sheinkman, V. (ITEP, Moscow (Russia)); Krasnokutsky, R.N.; Shuvalov, R.S.; Fedyakin, N.N.; Sushkov, V. (IHEP, Serpukhov (Russia)); Akopyan, M. (Inst. for Nuclear Research, Moscow (Russia)); Doke, T.; Kikuchi, J.; Hitachi, A.; Kashiwagi, T. (Science and Eng. Res. Lab., Waseda Univ., Tokyo (Japan)); Masuda, K.; Shibamura, E. (Saitama Coll. of Health (Japan)); Ishida, N. (Seikei Univ. (Japan)); Sugimoto, S. (INS, Univ. Tokyo (Japan))

    1993-03-20

    Recent R and D work on full length scintillating homogeneous liquid xenon/krypton (LXe/Kr) cells has established the essential properties for precision EM calorimeters: In-situ calibration using [alpha]'s, radiation hardness as well as the uniformity required for [delta]E/E[approx equal]0.5% for e/[gamma]'s above 50 GeV. (orig.).

  12. The CDF central and endwall hadron calorimeter

    International Nuclear Information System (INIS)

    Bertolucci, S.; Cordelli, M.; Eposito, B.; Curatolo, M.; Giromini, P.; Miscetti, S.; Sansoni, A.; Barnes, V.E.; Di Virgilio, A.; Garfinkel, A.F.; Kuhlmann, S.E.; Laasanen, A.T.

    1988-01-01

    The CDF central and endwall hadron calorimeter covers the polar region between 30 0 and 150 0 and a full 2π in azimuth. It consists of 48 steel-scintillator central modules with 2.5 cm sampling and 48 steel-scintillator endwall modules with 5.0 cm sampling. A general description of the detector is given. Calibration techniques and performance are discussed. Some results of the test beam studies are shown. (orig.)

  13. Measurement of ultrasound power using a calorimeter

    Science.gov (United States)

    Morgado, G.; Miqueleti, S.; Costa-Felix, R. P. B.

    2018-03-01

    This paper presents a comparison between the ultrasound power of a 1 MHz therapy equipment on the water using a calorimeter and a radiation force balance. For a range of 5 to 10 W, the results presented a normalized error less than 1, disclosing compatibility of the results from the developed system and the radiation force balance. The calorimetric method might be used as a faster and cheaper means for the verification of the ultrasonic power emitted by an equipment for physiotherapeutic treatment.

  14. Prototype calorimeters for the NA3 experiment

    CERN Multimedia

    1975-01-01

    The NA3 Experiment was set-up on the North Area of the SPS by the CERN/ Ecole Polytechnique/College de France/ Orsay/Saclay Collaboration, to study high transverse momentum leptons and hadrons from hadron collisions. The calorimeters measured the energy of hadrons (prototype on the right) and leptons (prototype on the left). They used a new type of plastic scintillator (plexipop). (see CERN Courier of November 1975) energy (prototype on the right)

  15. Upgrade of the ATLAS Tile Calorimeter Electronics

    International Nuclear Information System (INIS)

    Carrió, F

    2015-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (Phase-II) where the peak luminosity will increase 5 times compared to the design luminosity (10 34 cm −2 s −1 ) but with maintained energy (i.e. 7+7 TeV). An additional increase of the average luminosity with a factor of 2 can be achieved by luminosity levelling. This upgrade is expected to happen around 2024. The TileCal upgrade aims at replacing the majority of the on- and off- detector electronics to the extent that all calorimeter signals will be digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 Gbps optical links are used to read out all digitized data to the counting room while 5 Gbps down-links are used for synchronization, configuration and detector control. For the off-detector electronics a pre-processor (sROD) is being developed, which takes care of the initial trigger processing while temporarily storing the main data flow in pipeline and derandomizer memories. One demonstrator prototype module with the new calorimeter module electronics, but still compatible with the present system, is planned to be inserted in ATLAS this year

  16. Performance test of a TMS calorimeter

    International Nuclear Information System (INIS)

    Wild, B.

    1986-10-01

    Performance tests of a first calorimeter module using the room temperature liquid tetramethylsilane (TMS) as active element are described in detail. As absorber planed carbon steel slabs had been used. The charge yield is 70% of that in a very pure sample of the liquid. A long term stability of the signal with a lifetime of half a year has been realized. Experiences are described and the results explained in detail. (orig.) [de

  17. Pion showers in highly granular calorimeters

    Czech Academy of Sciences Publication Activity Database

    Cvach, Jaroslav

    2012-01-01

    Roč. 79, č. 4 (2012), s. 859-862 ISSN 0304-4289. [International Symposium on Lepton-Photon Interactions at High Energies /25./. Mumbai, 22.08.2011-27.08.2011] R&D Projects: GA MŠk LA09042 Institutional research plan: CEZ:AV0Z10100502 Keywords : International Linear Collider * particle flow algorithm * calorimeter resolution Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 0.562, year: 2012

  18. Electron Reconstruction in the CMS Electromagnetic Calorimeter

    CERN Document Server

    Meschi, Emilio; Seez, Christopher; Vikas, Pratibha

    2001-01-01

    This note describes the reconstruction of electrons using the electromagnetic calorimeter (ECAL) alone. This represents the first step in the High Level Trigger reconstruction and selection chain. By making "super-clusters" (i.e. clusters of clusters) much of the energy radiated by bremsstrahlung in the tracker material can be recovered. Representative performance figures for energy and position resolution in the barrel are given.

  19. A no-load RF calorimeter

    Science.gov (United States)

    Chernoff, R. C.

    1975-01-01

    The described device can be used to measure the output of any dc powered RF source. No dummy load is required for the measurements. The device is, therefore, called the 'no-load calorimeter' (NLC). The NLC measures the power actually fed to the antenna or another useful load. It is believed that the NLC can compete successfully with directional coupler type systems in measuring the output of high-power RF sources.

  20. Analytical heat transfer modeling of a new radiation calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Obame Ndong, Elysée [Department of Industrial Engineering and Maintenance, University of Sciences and Technology of Masuku (USTM), BP 941 Franceville (Gabon); Grenoble Electrical Engineering Laboratory (G2Elab), University Grenoble Alpes and CNRS, G2Elab, F38000 Grenoble (France); Gallot-Lavallée, Olivier [Grenoble Electrical Engineering Laboratory (G2Elab), University Grenoble Alpes and CNRS, G2Elab, F38000 Grenoble (France); Aitken, Frédéric, E-mail: frederic.aitken@g2elab.grenoble-inp.fr [Grenoble Electrical Engineering Laboratory (G2Elab), University Grenoble Alpes and CNRS, G2Elab, F38000 Grenoble (France)

    2016-06-10

    Highlights: • Design of a new calorimeter for measuring heat power loss in electrical components. • The calorimeter can operate in a temperature range from −50 °C to 150 °C. • An analytical model of heat transfers for this new calorimeter is presented. • The theoretical sensibility of the new apparatus is estimated at ±1 mW. - Abstract: This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from −50 °C to 150 °C. The aim of this modeling is the evaluation of the feasibility and performance of the calorimeter by assessing the measurement of power losses of some electrical devices by radiation, the influence of the geometry and materials. Finally a theoretical sensibility of the new apparatus is estimated at ±1 mW. From these results the calorimeter has been successfully implemented and patented.

  1. Design, Construction and Commissioning of the Digital Hadron Calorimeter - DHCAL

    CERN Document Server

    Adams, C; Bilki, B.; Butler, J.; Corriveau, F.; Cundiff, T.; Drake, G.; Francis, K.; Furst, B.; Guarino, V.; Haberichter, B.; Hazen, E.; Hoff, J.; Holm, S.; Kreps, A.; DeLurgio, P.; Matijas, Z.; Monte, L.Dal; Mucia, N.; Norbeck, E.; Northacker, D.; Onel, Y.; Pollack, B.; Repond, J.; Schlereth, J.; Skrzecz, F.; Smith, J.R.; Trojand, D.; Underwood, D.; Velasco, M.; Walendziak, J.; Wood, K.; Wu, S.; Xia, L.; Zhang, Q.; Zhao, A.

    2016-01-01

    A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of this prototype calorimeter.

  2. Some hadron calorimeter properties relevant to storage rings

    International Nuclear Information System (INIS)

    Corden, M.J.; Dowell, J.D.; Edwards, M.; Ellis, N.; Garvey, J.; Grant, D.; Homer, R.J.; Kenyon, I.R.; McMahon, T.; Schanz, G.; Sumorok, K.C.T.O.; Watkins, P.M.; Wilson, J.A.; Eisenhandler, E.; Gibson, W.R.; Kalmus, P.I.P.; Thompson, G.; Arnison, G.; Astbury, A.; Grayer, G.; Haynes, W.J.; Hill, D.; Nandi, A.K.; Roberts, C.; Shah, T.P.

    1982-01-01

    At wide angles in a storage ring environment, a substantial part of the energy seen by a hadron calorimeter can be in the form of very low momentum particles such as jet fragments or resonance cascade decay products. Data are presented on the deviations from Gaussian resolution and linear response for such low momentum particles. The differing responses to incident e - , μ - , π +- , K +- , p and anti p at momenta below 10 GeV/c are also compared. In addition, the authors discuss the significance of angle effects for a 4π calorimeter, and the problems of combining data from calorimeters with different physical characteristics. Experimental data are presented on the difference in hadron response between a fine grain (electromagnetic) lead calorimeter and a coarser (hadron) iron calorimeter, and on the dependence of the response on the energy sharing between the two calorimeters. (Auth.)

  3. Analytical heat transfer modeling of a new radiation calorimeter

    International Nuclear Information System (INIS)

    Obame Ndong, Elysée; Gallot-Lavallée, Olivier; Aitken, Frédéric

    2016-01-01

    Highlights: • Design of a new calorimeter for measuring heat power loss in electrical components. • The calorimeter can operate in a temperature range from −50 °C to 150 °C. • An analytical model of heat transfers for this new calorimeter is presented. • The theoretical sensibility of the new apparatus is estimated at ±1 mW. - Abstract: This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from −50 °C to 150 °C. The aim of this modeling is the evaluation of the feasibility and performance of the calorimeter by assessing the measurement of power losses of some electrical devices by radiation, the influence of the geometry and materials. Finally a theoretical sensibility of the new apparatus is estimated at ±1 mW. From these results the calorimeter has been successfully implemented and patented.

  4. Run 1 Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Heelan, Louise; The ATLAS collaboration

    2014-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. It is also useful for identification and reconstruction of muons due to good signal to noise ratio. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5000 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1% using radioactive source, laser and charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of proton-proton collisions acquired in 2011 and 2012. Results on the calorimeter performance are presented, including the absolute energy scale, timing, noise and associated stabilities. The results demonstrate that the Tile Calorimeter has performed well within the design ...

  5. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Hasib, Ahmed; The ATLAS collaboration

    2017-01-01

    Producing the very large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing CPU requirements when detailed detector simulations are not needed. During the LHC Run-1, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and it can be tuned to data more easily than GEANT4. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim makes use of statistical techniques such as principal component analysis, and a neural n...

  6. Beam tests of the ZEUS barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, A; Bienz, T; Caldwell, A; Chen, L; Derrick, M; Gialas, I; Hamri, A; Imlay, R; Kartik, S; Kim, H J; Kinnel, T; Kreutzmann, H; Li, C G; Lim, J N; Loveless, R; Lu, B; Mallik, U; McLean, K W; McNeil, R; Metcalf, W; Musgrave, B; Oh, B Y; Park, S; Parsons, J A; Reeder, D; Repond, J; Ritz, S; Roco, M T.P.; Sandler, P H; Sciulli, F; Smith, W H; Talaga, R L; Tzanakos, G; Wai, L; Wang, M Z; Whitmore, J; Wu, J; Yang, S [Argonne National Lab., IL (United States) Columbia Univ., New York, NY (United States) Nevis Labs., Irvington-on-Hudson, NY (United States) Univ. of Iowa, Iowa City, IA (United States) Louisiana State Univ., Baton Rouge, LA (United States) Ohio State Univ., Columbus, OH (United States) Pennsylvania State Univ., University Park, PA (United States) Virginia Polytechnic Inst., and State Univ., Blacksburg, VA (United States) Univ. of Wisconsin, Madison, WI (United States)

    1993-11-15

    A fully compensating uranium-scintillator calorimeter was constructed for the ZEUS detector at HERA. Several of the barrel calorimeter modules were subjected to beam tests at Fermilab before shipping them to DESY for installation. The calibrations of the modules used beams of electrons and hadrons, measuring the uniformity of the response, and checking the resolution. The runs also provided opportunity to test a large fraction of the actual ZEUS calorimeter readout system in an integrated beam environment more than one year before HERA turn on. The experiment utilized two computer controlled mechanical structures, one of which was capable of holding up to four modules in order to study shower containment, and a magnetic spectrometer with a high resolution beam tracking system. During two running periods, beams of 6 to 110 GeV containing e, [mu], [pi], and anti p were used. The results show energy resolutions of 35%/[radical]E for hadrons and 19%/[radical]E for electrons, uniformities at the 1% level, energy nonlinearity less than 1%, and equal response for electrons and hadrons. (orig.)

  7. An absorbed dose calorimeter for IMRT dosimetry

    International Nuclear Information System (INIS)

    Duane, S.; Aldehaybes, M.; Bailey, M.; Lee, N.D.; Thomas, C.G.; Palmans, H.

    2012-01-01

    A new calorimeter for dosimetry in small and complex fields has been built. The device is intended for the direct determination of absorbed dose to water in moderately small fields and in composite fields such as IMRT treatments, and as a transfer instrument calibrated against existing absorbed dose standards in conventional reference conditions. The geometry, materials and mode of operation have been chosen to minimize detector perturbations when used in a water phantom, to give a reasonably isotropic response and to minimize the effects of heat transfer when the calorimeter is used in non-reference conditions in a water phantom. The size of the core is meant to meet the needs of measurement in IMRT treatments and is comparable to the size of the air cavity in a type NE2611 ionization chamber. The calorimeter may also be used for small field dosimetry. Initial measurements in reference conditions and in an IMRT head and neck plan, collapsed to gantry angle zero, have been made to estimate the thermal characteristics of the device, and to assess its performance in use. The standard deviation (estimated repeatability) of the reference absorbed dose measurements was 0.02 Gy (0.6%). (authors)

  8. Upgrading the ATLAS Tile Calorimeter electronics

    CERN Document Server

    Souza, J; The ATLAS collaboration

    2014-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. Its main upgrade will occur for the High Luminosity LHC phase (phase 2) where the peak luminosity will increase 5-fold compared to the design luminosity (10exp34 cm−2s−1) but with maintained energy (i.e. 7+7 TeV). An additional increase of the average luminosity with a factor of 2 can be achieved by luminosity leveling. This upgrade will probably happen around 2023. The upgrade aims at replacing the majority of the on- and off-detector electronics so that all calorimeter signals are directly digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. The smallest independent on-detector electronics module has been reduced from 45 channels to 6, greatly reducing the consequences of a failure in the on-detector electronics. The size of t...

  9. Upgrade of the ATLAS Tile Calorimeter

    CERN Document Server

    Reed, Robert; The ATLAS collaboration

    2014-01-01

    The Tile Calorimeter (TileCal) is the main hadronic calorimeter covering the central region of the ATLAS experiment at LHC. TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC operation (Phase 2 around 2023) where the peak luminosity will increase 5x compared to the design luminosity (10^{34} cm^{-2}s^{-1}) but with maintained energy (i.e. 7+7 TeV). The TileCal upgrade aims to replace the majority of the on- and off-detector electronics so that all calorimeter signals can be digitized and directly sent to the off-detector electronics in the counting room. This will reduce pile-up problems and allow more complex trigger algorithms. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 Gbps optical links are used to read out all digitized data to t...

  10. Upgrading the ATLAS Tile Calorimeter electronics

    CERN Document Server

    Oreglia, M; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The main upgrade will occur for the High Luminosity LHC phase (phase 2) which is scheduled around 2022. The upgrade aims at replacing the majority of the on- and off- detector electronics so that all calorimeter signals are directly digitized and sent to the off-detector electronics in the counting room. An ambitious upgrade development program is pursued studying different electronics options. Three different options are presently being investigated for the front-end electronic upgrade. Which one to use will be decided after extensive test beam studies. High speed optical links are used to read out all digitized data to the counting room. For the off-detector electronics a new back-end architecture is being developed, including the initial trigger processing and pipeline memories. A demonstrator prototype read-out for a slice of the ...

  11. Upgrade of the ATLAS Tile Calorimeter Electronics

    CERN Document Server

    Moreno, P; The ATLAS collaboration

    2014-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (phase 2) where the peak luminosity will increase 5x compared to the design luminosity (10^34 cm−2s−1) but with maintained energy (i.e. 7+7 TeV). An additional increase of the average luminosity with a factor of 2 can be achieved by luminosity leveling. This upgrade is expected to happen around 2023. The TileCal upgrade aims at replacing the majority of the on- and off-detector electronics to the extent that all calorimeter signals will be digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 ...

  12. Upgrade of the ATLAS Tile Calorimeter

    CERN Document Server

    Moreno, P; The ATLAS collaboration

    2016-01-01

    The Tile Calorimeter (TileCal) is the central hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (Phase 2) where the peak luminosity will increase 5$\\times$ compared to the design luminosity ($10^{34} cm^{-2}s^{-1}$) but with maintained energy (i.e. 7+7 TeV). The TileCal upgrade aims at replacing the majority of the on- and off-detector electronics to the extent that all calorimeter signals will be digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 Gbps optical links are used to read out all digitized data to the counting room while 5 Gbps down-links are used for synchronization, c...

  13. Upgrade of the ATLAS Tile Calorimeter Electronics

    CERN Document Server

    Carrio, F

    2015-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (P hase - II ) where the pea k luminosity will increase 5 times compared to the design luminosity (10 34 cm −2 s −1 ) but with maintained energy (i.e. 7+7 TeV). An additional increase of the average luminosity with a factor of 2 can be achieved by luminosity levelling. This upgrade is expe cted to happen around 202 4 . The TileCal upgrade aims at replacing the majority of the on - and off - detector electronics to the extent that all calorimeter signals will be digitized and sent to the off - detector electronics in the counting room. To achieve th e required reliability, redundancy has been introduced at different levels. Three different options are presently being investiga...

  14. Upgrading the ATLAS Tile Calorimeter electronics

    CERN Document Server

    Carrio, F; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. Its main upgrade will occur for the High Luminosity LHC phase (phase 2) where the luminosity will have increased 5-fold compared to the design luminosity (1034 cm−2s−1) but with maintained energy (i.e. 7+7 TeV). An additional luminosity increase by a factor of 2 can be achieved by luminosity leveling. This upgrade will probably happen around 2022. The upgrade aims at replacing the majority of the on- and off- detector electronics so that all calorimeter signals are directly digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. An ambitious upgrade development program is pursued studying different electronics options. Three different options are presently being investigated for the front-end electronic upgrade. Which one to u...

  15. The New ATLAS Fast Calorimeter Simulation

    CERN Document Server

    Heath, Matthew Peter; The ATLAS collaboration

    2017-01-01

    Producing the large samples of simulated events required by many physics and performance studies with the ATLAS detector using the full GEANT4 detector simulation is highly CPU intensive. Fast simulation tools are a useful way of reducing the CPU requirements when detailed detector simulations are not needed. During Run-1 of the LHC, a fast calorimeter simulation (FastCaloSim) was successfully used in ATLAS. FastCaloSim provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitisation and reconstruction software, and it can be tuned to data more easily than Geant4. Now an improved version of FastCaloSim is in development, incorporating the experience with the version used during Run-1. The new FastCaloSim aims to overcome some limitations of the first version by improving the description of...

  16. Fast shower simulation in the ATLAS calorimeter

    International Nuclear Information System (INIS)

    Barberio, E; Boudreau, J; Mueller, J; Tsulaia, V; Butler, B; Young, C C; Cheung, S L; Savard, P; Dell'Acqua, A; Simone, A D; Gallas, M V; Ehrenfeld, W; Glazov, A; Placakyte, R; Marshall, Z; Rimoldi, A; Waugh, A

    2008-01-01

    The time to simulate pp collisions in the ATLAS detector is largely dominated by the showering of electromagnetic particles in the heavy parts of the detector, especially the electromagnetic barrel and endcap calorimeters. Two procedures have been developed to accelerate the processing time of electromagnetic particles in these regions: (1) a fast shower parameterisation and (2) a frozen shower library. Both work by generating the response of the calorimeter to electrons and positrons with Geant 4, and then reintroduce the response into the simulation at runtime. In the fast shower parameterisation technique, a parameterisation is tuned to single electrons and used later by simulation. In the frozen shower technique, actual showers from low-energy particles are used in the simulation. Full Geant 4 simulation is used to develop showers down to ∼ 1GeV, at which point the shower is terminated by substituting a frozen shower. Judicious use of both techniques over the entire electromagnetic portion of the ATLAS calorimeter produces an important improvement of CPU time. We discuss the algorithms and their performance in this paper

  17. Performance of the ATLAS Tile calorimeter

    CERN Document Server

    Bertoli, Gabriele; The ATLAS collaboration

    2015-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau­particles and missing transverse energy. TileCal is a scintillator­steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal front­end electronics read out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. The read­out system is responsible for reconstructing the data in real­time. The digitized signals are reconstructed with the Optimal Filtering algorithm, which computes for each channel the signal amplitude, time and quality factor at the required high rate. Each stage of the signal production from scintillation light to the signal reconstruc...

  18. First Half Of CMS Hadron Calorimeter Completed

    CERN Multimedia

    2001-01-01

    CMS HCAL electronics coordinator John Elias from Fermilab inspecting the assembled first half of the calorimeter. The first half barrel of the CMS hadron calorimeter was completed last month and assembly work on the elements of the second half commenced just last week. This is not a simple task considering the fact that the constructed half-barrel consists of eighteen 30 tonne segments each made with 0.15 mm tolerance. But through the work of everyone on the CMS hadron calorimeter team it is all moving forward. In the LHC, detection of particles produced in collisions of two proton beams requires measurement of their energy. To do this, the particle energy has to be changed into a form that can be easily measured. This is achieved by stopping the initial particles in a dense medium, where they create a shower of secondary particles. While particles that interact through electromagnetic forces (electrons and positrons) create relatively small showers, the size of showers created by hadrons, particles that i...

  19. Performance of the upgraded small angle tile calorimeter at LEP

    CERN Document Server

    Alvsvaag, S J; Barreira, G; Benvenuti, Alberto C; Bigi, M; Bonesini, M; Bozzo, M; Camporesi, T; Carling, H; Cassio, V; Castellani, L; Cereseto, R; Chignoli, F; Della Ricca, G; Dharmasiri, D R; Espirito-Santo, M C; Falk, E; Fenyuk, A; Ferrari, P; Gamba, D; Giordano, V; Guz, Yu; Guerzoni, M; Gumenyuk, S A; Hedberg, V; Jarlskog, G; Karyukhin, A N; Klovning, A; Konoplyannikov, A K; Kronkvist, I J; Lanceri, L; Leoni, R; Maeland, O A; Maio, A; Mazza, R; Migliore, E; Navarria, Francesco Luigi; Nossum, B; Obraztsov, V F; Onofre, A; Paganoni, M; Pegoraro, M; Peralta, L; Petrovykh, L P; Pimenta, M; Poropat, P; Prest, M; Read, A L; Romero, A; Shalanda, N A; Simonetti, L; Skaali, T B; Stugu, B; Terranova, F; Tomé, B; Torassa, E; Trapani, P P; Verardi, M G; Vallazza, E; Vlasov, E; Zaitsev, A

    1998-01-01

    The small angle tile calorimeter (STIC) provides calorimetric coverage in the very forward region of the DELPHI experiment at the CERN LEP collider. The structure of the calorimeters, built with so- called "shashlik" technique, $9 allows the insertion of tracking detectors within the sampling structure, in order to make it possible to determine the direction of the showering particle. Presented here are some results demonstrating the performance of the $9 calorimeter and of these tracking detectors at LEP. (5 refs).

  20. Design and construction of the ZEUS barrel calorimeter

    International Nuclear Information System (INIS)

    Repond, J.

    1990-01-01

    The mechanical design and construction techniques of the barrel calorimeter for the ZEUS detector are presented. The calorimeter uses alternate layers of depleted uranium and scintillator with one radiation length sampling. The unit cell has e/h = 1 which yields an optimal energy resolution for hadronic jets. We discuss the placing of the structural components and cracks between modules. Details of the construction and assembly effort needed to realize the total calorimeter are reported. 4 figs., 1 tab