WorldWideScience

Sample records for tuner pts piezo

  1. Mechanical study of the Saclay piezo tuner PTS (piezo tuning system) Care-SRF-WP8

    International Nuclear Information System (INIS)

    Bosland, P.; Wu, B.

    2005-03-01

    The present tuner is working inside Tesla test facility's cryo-modules without any piezo actuator. Thus the Lorentz force detuning in the pulsed mode of the accelerator is limiting the maximum accelerating field of cavity at about 25 MV/m. Previous studies and tests have demonstrated that the integration of piezo actuators in the tuner can lead to the compensation of the Lorentz force detuning at field higher than 35 MV/m. Our goal is now to develop and optimize a new tuner integrating piezo actuators. The mechanical studies are now finished and fabrication is in progress. This report presents the principle of this new system, its design and reviews the cavity frequency shifts during preparation process and assesses the forces applied by the cavity on the piezo actuators. (A.C.)

  2. The fast piezo-based frequency tuner for sc CH-cavities

    Energy Technology Data Exchange (ETDEWEB)

    Amberg, Michael [Helmholtz-Institut Mainz (HIM), Mainz (Germany); IAP University of Frankfurt, Frankfurt am Main (Germany); Aulenbacher, Kurt; Barth, Winfried [Helmholtz-Institut Mainz (HIM), Mainz (Germany); Busch, Marco; Dziuba, Florian; Podlech, Holger; Ratzinger, Ulrich [IAP University of Frankfurt, Frankfurt am Main (Germany)

    2014-07-01

    Superconducting (sc) structures have to fulfill strict mechanical requirements to assure a stable operation of a cavity. Even small mechanical disturbances caused by effects like microphonic noise, pressure fluctuations of the liquid helium bath or Lorentz force detuning can change the resonance frequency of the cavity in the range of several hundred kHz. To control the slow and fast frequency variations during operation a compact frequency tuner prototype equipped with a stepper motor and a piezo actuator has been developed at the Institute for Applied Physics (IAP) of Frankfurt University. The tuner design and the results of first mechanical tests at room temperature of the first prototype are presented.

  3. Development of a fast piezo-based frequency tuner for superconducting CH cavities

    International Nuclear Information System (INIS)

    Amberg, Michael

    2015-01-01

    In this thesis, a fast piezo-based frequency tuner for current and prospective superconducting (sc) CH-cavities has been developed. The novel tuning concept differs fundamentally from conventional tuning systems for superconducting cavities. So called dynamic bellow tuners are welded into the resonator to act against slow and fast frequency variations during operation. Because of their adjustable length it is possible to specifically influence the capacitance and therefore the resonance frequency of the cavity. To change the length of the dynamic bellow tuners the frequency tuner drive, which consists of a slow tuning device controlled by a stepper motor and a fast piezo-based tuning system, is mounted to the helium vessel of the cavity. To validate the whole tuning concept a frequency tuner drive prototype was built in the workshop of the Institute for Applied Physics (IAP) of Frankfurt University. First successful room temperature measurements show that the developed frequency tuning system is an excellent and promising candidate to fulfill the requirements of slow and fast frequency tuning of sc CH-cavities during operation. Furthermore, several coupled structural and electromagnetic simulations of the sc 325 MHz CH-cavity as well as the sc 217 MHz CH-cavity have been performed with the simulation softwares ANSYS Workbench and CST MicroWave Studio, respectively. With these simulations it was possible to reduce the required frequency range and thus the mechanical stroke of the dynamic bellow tuners on the one hand, and on the other hand the mechanical stability of the particular CH-cavity was investigated to avoid plastic deformations due to limiting external effects. To verify the accuracy of the coupled simulations the structural mechanical behaviour and the resulting frequency variations of the sc CH-cavities dependent on the external influences were measured at room temperature as well as at cryogenic temperatures around 4.2 K. The measurement results of both

  4. M10.6.9: Design and fabrication of AMC modules for controlling step motors, piezo and waveguide tuners

    CERN Document Server

    Przygoda, K; Kielar, E

    2011-01-01

    FLASH accelerator is using superconducting RF cavities to accelerate electron beam. These cavities must be precisely tuned to RF frequency due to very high Q factor (~109 unloaded Q and ~106 loaded Q). They are tuned by slight dimension change (particularly length) induced by tuners driven by step motors. For high gradients (~20MV/m and more) the cavities are dynamically detuned during RF pulse due to Lorentz Force Detuning (LFD). To keep them in resonance the fast tuners with piezos are used. Both slow and fast tuners need the control integrated with the LLRF system.

  5. Development and Testing of a Prototype Tuner for the CEBAF Upgrade Cryomodule

    International Nuclear Information System (INIS)

    G. Davis; J. Delayen; M. Drury; E. Feldl

    2001-01-01

    An upgrade cryomodule is being developed for CEBAF at Jefferson Lab. The high-gradient, low-current operation of the superconducting cavities puts stringent requirements on the accuracy of the frequency tuner: a resolution of 1 Hz over a range of 400 KHz. We have developed and tested such a tuner; it consists of a stepper-motor-driven coarse tuner, operating in parallel with a piezo-actuator-driven fine tuner. Tuner test procedures and results are summarized, including frequency resolution, range, and linearity (i.e. frequency vs. tuner position), as well as microphonic effects resulting from tuner operation

  6. A technique for monitoring fast tuner piezoactuator preload forces for superconducting rf cavities

    International Nuclear Information System (INIS)

    Pischalnikov, Y.; Branlard, J.; Carcagno, R.; Chase, B.; Edwards, H.; Orris, D.; Makulski, A.; McGee, M.; Nehring, R.; Poloubotko, V.; Sylvester, C.; Fermilab

    2007-01-01

    The technology for mechanically compensating Lorentz Force detuning in superconducting RF cavities has already been developed at DESY. One technique is based on commercial piezoelectric actuators and was successfully demonstrated on TESLA cavities [1]. Piezo actuators for fast tuners can operate in a frequency range up to several kHz; however, it is very important to maintain a constant static force (preload) on the piezo actuator in the range of 10 to 50% of its specified blocking force. Determining the preload force during cool-down, warm-up, or re-tuning of the cavity is difficult without instrumentation, and exceeding the specified range can permanently damage the piezo stack. A technique based on strain gauge technology for superconducting magnets has been applied to fast tuners for monitoring the preload on the piezoelectric assembly. The design and testing of piezo actuator preload sensor technology is discussed. Results from measurements of preload sensors installed on the tuner of the Capture Cavity II (CCII)[2] tested at FNAL are presented. These results include measurements during cool-down, warmup, and cavity tuning along with dynamic Lorentz force compensation

  7. A technique for monitoring fast tuner piezoactuator preload forces for superconducting rf cavities

    Energy Technology Data Exchange (ETDEWEB)

    Pischalnikov, Y.; Branlard, J.; Carcagno, R.; Chase, B.; Edwards, H.; Orris, D.; Makulski, A.; McGee, M.; Nehring, R.; Poloubotko, V.; Sylvester, C.; /Fermilab

    2007-06-01

    The technology for mechanically compensating Lorentz Force detuning in superconducting RF cavities has already been developed at DESY. One technique is based on commercial piezoelectric actuators and was successfully demonstrated on TESLA cavities [1]. Piezo actuators for fast tuners can operate in a frequency range up to several kHz; however, it is very important to maintain a constant static force (preload) on the piezo actuator in the range of 10 to 50% of its specified blocking force. Determining the preload force during cool-down, warm-up, or re-tuning of the cavity is difficult without instrumentation, and exceeding the specified range can permanently damage the piezo stack. A technique based on strain gauge technology for superconducting magnets has been applied to fast tuners for monitoring the preload on the piezoelectric assembly. The design and testing of piezo actuator preload sensor technology is discussed. Results from measurements of preload sensors installed on the tuner of the Capture Cavity II (CCII)[2] tested at FNAL are presented. These results include measurements during cool-down, warmup, and cavity tuning along with dynamic Lorentz force compensation.

  8. Piezoelectric Tuner Compensation of Lorentz Detuning in Superconducting Cavities

    International Nuclear Information System (INIS)

    Jean Delayen; Davis, G.

    2003-01-01

    Pulsed operation of superconducting cavities can induce large variations of the resonant frequency through excitation of the mechanical modes by the radiation pressure. The phase and amplitude control system must be able to accommodate this frequency variation; this can be accomplished by increasing the capability of the rf power source. Alternatively, a piezo electric tuner can be activated at the same repetition rate as the rf to counteract the effect of the radiation pressure. We have demonstrated such a system on the prototype medium beta SNS cryomodule with a reduction of the dynamic Lorentz detuning during the rf pulse by a factor of 3. Piezo electric tuners can also be used to reduce the level of microphonics in low-current cw accelerators. We have measured the amplitude and phase of the transfer function of the piezo control system (from input voltage to cavity frequency) up to several kHz

  9. Pulse width modulation based pneumatic frequency tuner of the superconducting resonators at IUAC

    International Nuclear Information System (INIS)

    Pandey, A.; Suman, S.K.; Mathuria, D.S.

    2015-01-01

    The existing phase locking scheme of the quarter wave resonators (QWR) used in superconducting linear accelerator (LINAC) of IUAC consists of a fast time (electronic) and a slow time (pneumatic) control. Presently, piezo based mechanical tuners are being used to phase lock the resonators installed in the second and third accelerating modules of LINAC. However, due to space constraint, the piezo tuner can't be implemented on the resonators of the first accelerating module. Therefore, helium gas operated mechanical tuners are being used to phase lock the resonators against the master oscillator (MO) frequency. The present pneumatic frequency tuner has limitations of non-linearity, hysteresis and slow response time. To overcome these problems and to improve the dynamics of the existing tuner, a new pulse width modulation (PWM) based pneumatic frequency tuning system was adopted and successfully tested. After successful test, the PWM based pneumatic frequency tuner was installed in four QWR of the first accelerating module of LINAC. During beam run the PWM based frequency tuner performed well and the cavities could be phase locked at comparatively higher accelerating fields. A comparison of the existing tuning mechanism and the PWM based tuning system along with the test results will be presented in the paper. (author)

  10. Study of piezo-actuators for the improvement of the frequency tuning and setup of a quench locating system for the accelerating structures of the S-DALINAC

    International Nuclear Information System (INIS)

    Sievers, Sven Thorsten

    2013-01-01

    The intention of this doctoral thesis was to find a replacement for the magnetostrictive fine tuners of the superconducting accelerating cavities of the S-DALINAC and to enlarge the range of diagnostics for these cavities. For these purposes a vertical bath cryostat has been assembled and put into operation. Within the framework of this thesis that cryostat was used (i) to test stroke and reliability of modern piezo actuators in liquid helium at 4 and 2 K and (ii) to set up a newly developed system for the localization of quenches in superconducting cavities based on second sound in superfluid helium. The negative impact of magnetic fields on the quality factor of superconducting cavities make the operation of magnetostrictive tuners nearby the cavities disadvantageous. In order to avoid a decrease of the quality factor of the cavities the magnetostrictive tuners should be replaced by non-magnetic ones. For that purpose modern piezo actuators were tested within this doctoral thesis relating to their stroke at cryogenic temperatures, their compatibility with the RF-control system of the S-DALINAC and their operational reliability in superfluid helium. The results indicate the possibility of operation of these actuators. Because piezo actuators of the same stroke only have the seventh part of length of a magnetostrictive tuner, it is possible to operate several piezo actuators at every cavity. This increases not only the range of the tuning system but also its reliability. Already tiny defects at the inner surface of superconducting cavities can cause quenching before the designed field intensity is reached. A quench results in waves of second sound in superfluid helium. The second sound can be measured by special microphones, so called Oscillating Superleak Transducers (OST), and the location of quenching can be calculated via triangulation. Such a system has been built up and tested successfully in the context of this doctoral thesis. The visual examination of the

  11. The Influence of Tuners and Temperature on the Higher Order Mode Spectrum for 1.3 GHz SCRF Cavities

    CERN Document Server

    Ainsworth, R; Zhang, P; Grecki, M; Baboi, N; Wamsat, T; Eddy, N

    2013-01-01

    Higher Order Modes (HOMs) are of concern for superconducting cavities as they can drive instabilities and so are usually damped and monitored. With special dedicated electronics, HOMs can provide information on the position on the beam. It has been proposed that piezo tuners used to keep the cavities operating at 1.3 GHz could alter the HOM spectrum altering the calibration constants used to read out the beam position affecting long term stability of the system. Also, of interest is how the cavity reacts to the slow tuner. Detuning and the retuning the cavity may alter the HOM spectrum. This is of particular interest for future machines not planning to use dedicated HOM damping as the tuning procedure may shift the frequency of HOMs onto dangerous resonances. The effect of temperature on the HOM spectrum is also investigated. An investigation of these effects has been performed at FLASH and the results are presented.

  12. Development of Control System for Fast Frequency Tuners of Superconducting Resonant Cavities for FLASH and XFEL Experiments

    CERN Document Server

    Przygoda, K

    2011-01-01

    This dissertation covers the recent research and development (R&D) activities of control systems for the fast frequency tuners of TESLA cavities and predicts the implications foreseen for large scale machines such as the FLASH and the planned XFEL. In particular, the framework of the presented activities is the effort toward the: 1. R&D of the driving circuit, 2. R&D of the control algorithm, 3. R&D of the control system. The main result of these activities is the permanent installation of the target piezo control system and its commissioning for 40 cavities divided into 5 accelerating modules at the DESY FLASH facility. The author’s contribution was the study of possible designs of high-voltage, high-current power amplifiers, used for driving the fast frequency tuners, shows that several parameters of such a device needs to be considered. The most important parameter is the input and output power estimation. This arises from the fact that the estimation is the most crucial issue for both po...

  13. Fast Ferroelectric L-band Tuner

    International Nuclear Information System (INIS)

    Kazakov, S. Yu.; Yakovlev, V. P.; Hirshfield, J. L.; Kanareykin, A. D.; Nenasheva, E. A.

    2006-01-01

    Description is given of a preliminary conceptual design for a tuner that employs a new ferroelectric ceramic that allows fast changes in coupling between the SRF acceleration structure of a linac and the external RF feeding line. The switching time of this device is in the range of a few microseconds. Utilization of this tuner is predicted to decrease Ohmic losses in the acceleration structure and thereby to reduce the power consumption of the linac. Using parameters of the TESLA-800 collider as an example, it is shown that it may be possible to reduce the ac mains power consumption by 12 MW, or about by 10%. The design of the tuner that is described allows reduced pulsed and average heating of the ferroelectric ceramics

  14. Fast ferrite tuner for the BNL synchrotron light source

    International Nuclear Information System (INIS)

    Pivit, E.; Hanna, S.M.; Keane, J.

    1991-01-01

    A new type of ferrite tuner has been tested at the BNL. The ferrite tuner uses garnet slabs partially filling a stripline. One of the important features of the tuner is that the ferrite is perpendicularly biased for operation above FMR, thus reducing the magnetic losses. A unique design was adopted to achieve the efficient cooling. The principle of operation of the tuner as well as our preliminary results on tuning a 52 MHz cavity are reported. Optimized conditions under which we demonstrated linear tunability of 80 KHz are described. The tuner's losses and its effect on higher-order modes in the cavity are discussed. 2 refs., 8 figs

  15. Tuner Design for PEFP Superconducting RF Cavities

    International Nuclear Information System (INIS)

    Tang, Yazhe; An, Sun; Zhang, Liping; Cho, Yong Sub

    2009-01-01

    A superconducting radio frequency (SRF) cavity will be used to accelerate a proton beam after 100 MeV at 700 MHz in a linac of the Proton Engineering Frontier Project (PEFP) and its extended project. In order to control the SRF cavity's operating frequency at a low temperature, a new tuner has been developed for the PEFP SRF cavities. Each PEFP superconducting RF cavity has one tuner to match the cavity resonance frequency with the desired accelerator operating frequency; or to detune a cavity frequency a few bandwidths away from a resonance, so that the beam will not excite the fundamental mode, when the cavity is not being used for an acceleration. The PEFP cavity tuning is achieved by varying the total length of the cavity. The length of the cavity is controlled differentially by tuner acting with respect to the cavity body. The PEFP tuner is attached to the helium vessel and drives the cavity Field Probe (FP) side to change the frequency of the cavity

  16. Fast Ferroelectric L-Band Tuner for Superconducting Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2011-03-01

    Analysis and modeling is presented for a fast microwave tuner to operate at 700 MHz which incorporates ferroelectric elements whose dielectric permittivity can be rapidly altered by application of an external voltage. This tuner could be used to correct unavoidable fluctuations in the resonant frequency of superconducting cavities in accelerator structures, thereby greatly reducing the RF power needed to drive the cavities. A planar test version of the tuner has been tested at low levels of RF power, but at 1300 MHz to minimize the physical size of the test structure. This test version comprises one-third of the final version. The tests show performance in good agreement with simulations, but with losses in the ferroelectric elements that are too large for practical use, and with issues in bonding of ferroelectric elements to the metal walls of the tuner structure.

  17. Fast Ferroelectric L-Band Tuner for Superconducting Cavities

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    2011-01-01

    Analysis and modeling is presented for a fast microwave tuner to operate at 700 MHz which incorporates ferroelectric elements whose dielectric permittivity can be rapidly altered by application of an external voltage. This tuner could be used to correct unavoidable fluctuations in the resonant frequency of superconducting cavities in accelerator structures, thereby greatly reducing the RF power needed to drive the cavities. A planar test version of the tuner has been tested at low levels of RF power, but at 1300 MHz to minimize the physical size of the test structure. This test version comprises one-third of the final version. The tests show performance in good agreement with simulations, but with losses in the ferroelectric elements that are too large for practical use, and with issues in bonding of ferroelectric elements to the metal walls of the tuner structure.

  18. ANT tuner retrofit for LEB cavity

    International Nuclear Information System (INIS)

    Walling, L.; Goren, Y.; Kwiatkowski, S.

    1994-03-01

    This report describes a ferrite tuner design for the LEB cavity that utilizes techniques for bonding ferrite to metallic cooling plates that is utilized in the high-power rf and microwave industry. A test tuner was designed to fit into the existing LEB-built magnet and onto the Grimm LEB Cavity. It will require a new vacuum window in order to attain maximal tuning range and high voltage capability and a new center conductor of longer length and a different vacuum window connection than the Grimm center conductor. However, the new center conductor will be essentially identical to the Grimm center conductor in its basic construction and in the way it connects to the stand for support. The tuner is mechanically very similar to high-power stacked circulators built by ANT of Germany and was designed according to ANT's established engineering and design criteria and SSC LEB tuning and power requirements. The tuner design incorporates thin tiles of ferrite glued using a high-radiation-resistance epoxy to copper-plated stainless steel cooling plates of thickness 6.5 mm with water cooling channels inside the plates. The cooling plates constitute 16 pie-shaped segments arranged in a disk. They are electrically isolated from each other to suppress eddy currents. Five of these disks are arranged in parallel with high-pressure rf contacts between the plates at the outer radius. The end walls are slotted copper-plated stainless steel of thickness 3 mm

  19. Piezo-Stellantrieb

    OpenAIRE

    Mehlkopp, K.

    1992-01-01

    Piezo actuators are used for example in so-called fast tool servo systems with which tools can be fed at high frequency. The disadvantage here is the heat loss occurring in the piezo element increasing with rising frequency. Thus, the maximum feed frequency of such piezo actuators is limited. In order to permit high feed frequencies with the piezo actuator, the temperature of the piezo element is adapted to the ambient temperature of the piezo element. As a result of this thermal stabilizatio...

  20. Fast Ferroelectric L-Band Tuner for Superconducting Cavities

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    2012-01-01

    Design, analysis, and low-power tests are described on a ferroelectric tuner concept that could be used for controlling external coupling to RF cavities for the superconducting Energy Recovery Linac (ERL) in the electron cooler of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). The tuner configuration utilizes several small donut-shaped ferroelectric assemblies, which allow the design to be simpler and more flexible, as compared to previous designs. Design parameters for 704 and 1300 MHz versions of the tuner are given. Simulation results point to efficient performance that could reduce by a factor-of-ten the RF power levels required for driving superconducting cavities in the BNL ERL.

  1. Fast Ferroelectric L-Band Tuner for Superconducting Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2012-07-03

    Design, analysis, and low-power tests are described on a ferroelectric tuner concept that could be used for controlling external coupling to RF cavities for the superconducting Energy Recovery Linac (ERL) in the electron cooler of the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). The tuner configuration utilizes several small donut-shaped ferroelectric assemblies, which allow the design to be simpler and more flexible, as compared to previous designs. Design parameters for 704 and 1300 MHz versions of the tuner are given. Simulation results point to efficient performance that could reduce by a factor-of-ten the RF power levels required for driving superconducting cavities in the BNL ERL.

  2. Fast Ferroelectric L-Band Tuner for ILC Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L

    2010-03-15

    Design, analysis, and low-power tests are described on a 1.3 GHz ferroelectric tuner that could find application in the International Linear Collider or in Project X at Fermi National Accelerator Laboratory. The tuner configuration utilizes a three-deck sandwich imbedded in a WR-650 waveguide, in which ferroelectric bars are clamped between conducting plates that allow the tuning bias voltage to be applied. Use of a reduced one-third structure allowed tests of critical parameters of the configuration, including phase shift, loss, and switching speed. Issues that were revealed that require improvement include reducing loss tangent in the ferroelectric material, development of a reliable means of brazing ferroelectric elements to copper parts of the tuner, and simplification of the mechanical design of the configuration.

  3. Piezo1

    Science.gov (United States)

    Gottlieb, Philip A.; Sachs, Frederick

    2012-01-01

    Piezo ion channels have been found to be essential for mechanical responses in cells. These channels were first shown to exist in Neuro2A cells, and the gene was identified by siRNAs that diminished the mechanical response. Piezo channels are approximately 2500 amino acids long, have between 24–32 transmembrane regions, and appear to assemble into tetramers and require no other proteins for activity. They have a reversal potential around 0 mV and show voltage dependent inactivation. The channel is constitutively active in liposomes, indicating that no cytoskeletal elements are required. Heterologous expression of the Piezo protein can create mechanical sensitivity in otherwise insensitive cells. Piezo1 currents in outside-out patches were blocked by the extracellular MSC inhibitor peptide GsMTx4. Both enantiomeric forms of GsMTx4 inhibited channel activity in a manner similar to endogenous mechanical channels. Piezo1 can adopt a tonic (non-inactivating) form with repeated stimulation. The transition to the non-inactivating form generally occurs in large groups of channels, indicating that the channels exist in domains, and once the domain is compromised, the members simultaneously adopt new properties. Piezo proteins are associated with physiological responses in cells, such as the reaction to noxious stimulus of Drosophila larvae. Recent work measuring cell crowding, shows that Piezo1 is essential for the removal of extra cells without apoptosis. Piezo1 mutations have also been linked to the pathological response of red blood cells in a genetic disease called Xerocytosis. These finding suggest that Piezo1 is a key player in cells’ responses to mechanical stimuli. PMID:22790400

  4. Inductive tuners for microwave driven discharge lamps

    Science.gov (United States)

    Simpson, James E.

    1999-01-01

    An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

  5. Tuners, microphonics, and control systems in superconducting accelerating structures

    International Nuclear Information System (INIS)

    Doolittle, L.R.

    1990-01-01

    Manufacturing tolerances, thermal stresses, acoustic noise, and cooling fluid pressure fluctuations all conspire to make the field in the cavity not precisely what the accelerator physicist has in mind. Tuners and control systems are the tools used to fight back: they regulate the field in the cavity to the desired magnitude and phase. Amplitude and phase stabilities are usually of greater concern in superconducting cavities than in copper cavities. The key to achieving a stable gradient and phase is feedback. A probe must be placed in the cavity itself to sense the present cavity status. Electronic control is then given the responsibility to correct for any measured disturbance. The electronic modulation of forward power has been implemented in a number of ways. Perhaps the easiest implementation to understand has two separate control loops, one for amplitude and one for phase (phase-amplitude loops). Other major electronic control devices include complex phasor modulator (CPM-amplitude loops), vector loop, and variable reactance. 'Slow' tuners are used when the tuning range of the 'fast' tuner plus electronic tuning is not enough to compensate for unpredictability or drift in the static frequency setting. (N.K.)

  6. Demystifying Mechanosensitive Piezo Ion Channels.

    Science.gov (United States)

    Xu, X Z Shawn

    2016-06-01

    Mechanosensitive channels mediate touch, hearing, proprioception, and blood pressure regulation. Piezo proteins, including Piezo1 and Piezo2, represent a new class of mechanosensitive channels that have been reported to play key roles in most, if not all, of these modalities. The structural architecture and molecular mechanisms by which Piezos act as mechanosensitive channels, however, remain mysterious. Two new studies have now provided critical insights into the atomic structure and molecular basis of the ion permeation and mechano-gating properties of the Piezo1 channel.

  7. Tuner control system of Spoke012 SRF cavity for C-ADS injector I

    Science.gov (United States)

    Liu, Na; Sun, Yi; Wang, Guang-Wei; Mi, Zheng-Hui; Lin, Hai-Ying; Wang, Qun-Yao; Liu, Rong; Ma, Xin-Peng

    2016-09-01

    A new tuner control system for spoke superconducting radio frequency (SRF) cavities has been developed and applied to cryomodule I of the C-ADS injector I at the Institute of High Energy Physics, Chinese Academy of Sciences. We have successfully implemented the tuner controller based on Programmable Logic Controller (PLC) for the first time and achieved a cavity tuning phase error of ±0.7° (about ±4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper presents preliminary experimental results based on the PLC tuner controller under proton beam commissioning. Supported by Proton linac accelerator I of China Accelerator Driven sub-critical System (Y12C32W129)

  8. Synergy between Piezo1 and Piezo2 channels confers high-strain mechanosensitivity to articular cartilage

    Science.gov (United States)

    Lee, Whasil; Leddy, Holly A.; Chen, Yong; Lee, Suk Hee; Zelenski, Nicole A.; McNulty, Amy L.; Wu, Jason; Beicker, Kellie N.; Coles, Jeffrey; Zauscher, Stefan; Grandl, Jörg; Sachs, Frederick; Liedtke, Wolfgang B.

    2014-01-01

    Diarthrodial joints are essential for load bearing and locomotion. Physiologically, articular cartilage sustains millions of cycles of mechanical loading. Chondrocytes, the cells in cartilage, regulate their metabolic activities in response to mechanical loading. Pathological mechanical stress can lead to maladaptive cellular responses and subsequent cartilage degeneration. We sought to deconstruct chondrocyte mechanotransduction by identifying mechanosensitive ion channels functioning at injurious levels of strain. We detected robust expression of the recently identified mechanosensitive channels, PIEZO1 and PIEZO2. Combined directed expression of Piezo1 and -2 sustained potentiated mechanically induced Ca2+ signals and electrical currents compared with single-Piezo expression. In primary articular chondrocytes, mechanically evoked Ca2+ transients produced by atomic force microscopy were inhibited by GsMTx4, a PIEZO-blocking peptide, and by Piezo1- or Piezo2-specific siRNA. We complemented the cellular approach with an explant-cartilage injury model. GsMTx4 reduced chondrocyte death after mechanical injury, suggesting a possible therapy for reducing cartilage injury and posttraumatic osteoarthritis by attenuating Piezo-mediated cartilage mechanotransduction of injurious strains. PMID:25385580

  9. Piezotronics and piezo-phototronics

    CERN Document Server

    Wang, Zhong Lin

    2014-01-01

    This book introduces the fundamentals of piezotronics and piezo-phototronics, and shows how the functionality of piezotroics and piezo-phototronics are complementary to CMOS technology. Describes applications in sensing, nanorobotics and many other areas.

  10. Development of a movable plunger tuner for the high-power RF cavity for the PEP-II B-factory

    International Nuclear Information System (INIS)

    Schwarz, H.D.; Fant, K.; Judkins, J.G.

    1997-05-01

    A 10 cm diameter by 5 cm travel plunger tuner was developed for the PEP-II RF copper cavity system. The single cell cavity including the tuner is designed to operate up to 150 kW of dissipated RF power are specially placed 8.5 cm away from the inside wall of the cavity to avoid fundamental and higher order mode resonances. The spring fingers are made of dispersion-strengthened copper to accommodate relatively high heating. The design, alignment, testing and performance of the tuner is described

  11. Plant specific PTS analysis of Kori Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Sung-Yull, Hong; Changheui, Jang; Ill-Seok, Jeong [Korea Eletric Power Research Inst., Daejon (Korea, Republic of); Tae-Eun, Jin [Korea Power Engineering Company, Yonging (Korea, Republic of)

    1997-09-01

    Currently, a nuclear PLIM (Plant Lifetime Management) program is underway in Korea to extend the operation life of Kori-1 which was originally licensed for 30 years. For the life extension of nuclear power plants, the residual lives of major components should be evaluated for the extended operation period. According to the residual life evaluation of reactor pressure vessel, which was classified as one of the major components crucial to life extension, it was found by screening analysis that reference PTS temperature would exceed screening criteria before the target extended operation years. In order to deal with this problem, a plant-specific PTS analysis for Kori-1 RPV has been initiated. In this paper, the relationship between PTS analysis and Kori-1 PLIM program is briefly described. The plant-specific PTS analysis covers system transient analysis, downcomer mixing analysis, and probabilistic fracture mechanics analysis to check the integrity or RPV during various PTS transients. The step-by-step procedure of the analysis will be described in detail. Finally, various issues regarding RPV materials and its integrity will be briefly mentioned, and their implications on Kori-1 PTS analysis will be discussed. Despite of the screening analysis result concern, it is now expected that Kori-1 PTS issues can be handled through the plant-specific PTS analysis. (author). 14 refs, 4 figs, 2 tabs.

  12. Transduction of Repetitive Mechanical Stimuli by Piezo1 and Piezo2 Ion Channels

    Directory of Open Access Journals (Sweden)

    Amanda H. Lewis

    2017-06-01

    Full Text Available Several cell types experience repetitive mechanical stimuli, including vein endothelial cells during pulsating blood flow, inner ear hair cells upon sound exposure, and skin cells and their innervating dorsal root ganglion (DRG neurons when sweeping across a textured surface or touching a vibrating object. While mechanosensitive Piezo ion channels have been clearly implicated in sensing static touch, their roles in transducing repetitive stimulations are less clear. Here, we perform electrophysiological recordings of heterologously expressed mouse Piezo1 and Piezo2 responding to repetitive mechanical stimulations. We find that both channels function as pronounced frequency filters whose transduction efficiencies vary with stimulus frequency, waveform, and duration. We then use numerical simulations and human disease-related point mutations to demonstrate that channel inactivation is the molecular mechanism underlying frequency filtering and further show that frequency filtering is conserved in rapidly adapting mouse DRG neurons. Our results give insight into the potential contributions of Piezos in transducing repetitive mechanical stimuli.

  13. Piezo-electrostrictive ceramics

    International Nuclear Information System (INIS)

    Kim, Ho Gi; Shin, Byeong Cheol

    1991-09-01

    This book deals with principle and the case of application of piezo-electrostrictive ceramics, which includes definition of piezoelectric materials and production and development of piezoelectric materials, coexistence of Pb(zr, Ti)O 3 ceramics on cause of coexistence in MPB PZT ceramics, electrostrictive effect of oxide type perovskite, practical piezo-electrostrictive materials, and breaking strength, evaluation technique of piezoelectric characteristic, and piezoelectric accelerometer sensor like printer head, ink jet and piezoelectric relay.

  14. Description of code system PLES/PTS for evaluation of pressure vessel integrity during PTS events

    International Nuclear Information System (INIS)

    Hirano, Masashi; Kohsaka, Atsuo.

    1992-02-01

    A code system PLES/PTS has been developed at the Japan Atomic Energy Research Institute (JAERI) to evaluate the integrity of the pressure vessel during plant thermal-hydraulic transients related to pressurized thermal shock (PTS) in a pressurized water reactor (PWR). The code system consists of several member codes to analyse the thermal-mixing behavior of emergency core cooling (ECC) water and primary coolant, transient stress distribution within the vessel wall, and crack growth behavior at the inner surface of the vessel. The crack growth behavior is evaluated by comparing the stress intensity factor (k I ) with the crack initiation toughness (k Ic ) and crack arrest toughness (k Ic ), taking into account the fast neutron irradiation embrittlement. This report describes the methods and models applied in PLES/PTS and the input data requirements. (author)

  15. Dependence of ion beam current on position of mobile plate tuner in multi-frequencies microwaves electron cyclotron resonance ion source

    International Nuclear Information System (INIS)

    Kurisu, Yosuke; Kiriyama, Ryutaro; Takenaka, Tomoya; Nozaki, Dai; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2012-01-01

    We are constructing a tandem-type electron cyclotron resonance ion source (ECRIS). The first stage of this can supply 2.45 GHz and 11-13 GHz microwaves to plasma chamber individually and simultaneously. We optimize the beam current I FC by the mobile plate tuner. The I FC is affected by the position of the mobile plate tuner in the chamber as like a circular cavity resonator. We aim to clarify the relation between the I FC and the ion saturation current in the ECRIS against the position of the mobile plate tuner. We obtained the result that the variation of the plasma density contributes largely to the variation of the I FC when we change the position of the mobile plate tuner.

  16. Voltage gating of mechanosensitive PIEZO channels.

    Science.gov (United States)

    Moroni, Mirko; Servin-Vences, M Rocio; Fleischer, Raluca; Sánchez-Carranza, Oscar; Lewin, Gary R

    2018-03-15

    Mechanosensitive PIEZO ion channels are evolutionarily conserved proteins whose presence is critical for normal physiology in multicellular organisms. Here we show that, in addition to mechanical stimuli, PIEZO channels are also powerfully modulated by voltage and can even switch to a purely voltage-gated mode. Mutations that cause human diseases, such as xerocytosis, profoundly shift voltage sensitivity of PIEZO1 channels toward the resting membrane potential and strongly promote voltage gating. Voltage modulation may be explained by the presence of an inactivation gate in the pore, the opening of which is promoted by outward permeation. Older invertebrate (fly) and vertebrate (fish) PIEZO proteins are also voltage sensitive, but voltage gating is a much more prominent feature of these older channels. We propose that the voltage sensitivity of PIEZO channels is a deep property co-opted to add a regulatory mechanism for PIEZO activation in widely different cellular contexts.

  17. RESULTS OF ACCELERATED LIFE TESTING OF LCLS-II CAVITY TUNER MOTOR

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Daly, Edward F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Pischalnikov, Yuriy [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2018-04-01

    An Accelerated Life Test (ALT) of the Phytron stepper motor used in the LCLS-II cavity tuner has been conducted at JLab. Since the motor will reside inside the cryomodule, any failure would lead to a very costly and arduous repair. As such, the motor was tested for the equivalent of 30 lifetimes before being approved for use in the production cryomodules. The 9-cell LCLS-II cavity is simulated by disc springs with an equivalent spring constant. Plots of the motor position vs. tuner position ' measured via an installed linear variable differential transformer (LVDT) ' are used to measure motor motion. The titanium spindle was inspected for loss of lubrication. The motor passed the ALT, and is set to be installed in the LCLS-II cryomodules.

  18. Elaboration and verification of a PTS model

    Energy Technology Data Exchange (ETDEWEB)

    Martins, G.P. de; Terra, J L; Di Lorenzo, R; Mansur, T R [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil); Prifo, S B [Atomic Energy Research Inst. AEKI/KFKI (Hungary)

    1997-09-01

    This work concerns to pressurize the thermal shock (PTS) phenomena, it is rapid cooldown of the primary system by low temperature water injection from the emergency core cooling system (ECCS). To assess the effect of a PTS event calculations and experimental work are equally necessary. The purpose of the present was to prepare the PTS analysis of Angra II RPV located near to Rio de Janeiro. This paper presents the method and the results of the calculations used to design an optimal RPV model. (author). 4 refs, 7 figs, 6 tabs.

  19. Modified PTS-based PAPR Reduction for FBMC-OQAM Systems

    Science.gov (United States)

    Deng, Honggui; Ren, Shuang; Liu, Yan; Tang, Chengying

    2017-10-01

    The filter bank multicarrier with offset quadrature amplitude modulation (FBMC-OQAM) has been raised great concern in the 5G communication research. However FBMC-OQAM has also the inherent drawback of high peak-to-average power ratio (PAPR) that should be addressed. Due to the overlapping structure of FBMC-OQAM signals, it is proven that directly employing conventional partial transmit sequence (PTS) scheme proposed for OFDM to FBMC-OQAM is ineffective. In this paper, we propose a modified PTS-based scheme by employing phase rotation factors to optimize only the phase of the sparse peak signals, called as sparse PTS (S-PTS) scheme. Theoretical analysis and simulation results show that the proposed S-PTS scheme provides a significant PAPR reduction performance with lower computational complexity.

  20. Advanced impedance matching system for ICRF heating using innovative twin stub tuner and frequency variation

    International Nuclear Information System (INIS)

    Kumazawa, R.; Saito, K.; Kasahara, H.; Seki, T.; Mutoh, T.; Shimpo, F.; Nomura, G.; Kato, A.; Okada, H.; Zhao, Y.; Kwak, J.G.; Yoon, J.S.

    2008-01-01

    Ion cyclotron range of frequency (ICRF) heating has been a reliable tool for steady-state plasma heating with high RF power of several tens of megawatts. However, a sudden increase in the reflected RF power during ICRF heating experiments with ELMy H-mode plasmas is an issue which must be solved for future fusion experimental devices or fusion reactors. This paper describes an innovative ICRF heating system using a frequency feedback control to reduce the reflected power in response to the rapid change in the plasma impedance in the ELMy H-mode plasma. A twin stub tuner has been newly invented for this purpose. The feasibility of keeping the reflected RF power fraction at a low level, e.g. 1%, is demonstrated even with a large change in plasma resistance, e.g. 2 ∼ 8Ω. Calculated and experimental results are presented for the conventional double stub tuner impedance matching system equipped with the twin stub tuner.

  1. The Rhizobium etli rpoN locus: DNA sequence analysis and phenotypical characterization of rpoN, ptsN, and ptsA mutants.

    Science.gov (United States)

    Michiels, J; Van Soom, T; D'hooghe, I; Dombrecht, B; Benhassine, T; de Wilde, P; Vanderleyden, J

    1998-04-01

    The rpoN region of Rhizobium etli was isolated by using the Bradyrhizobium japonicum rpoN1 gene as a probe. Nucleotide sequence analysis of a 5,600-bp DNA fragment of this region revealed the presence of four complete open reading frames (ORFs), ORF258, rpoN, ORF191, and ptsN, coding for proteins of 258, 520, 191, and 154 amino acids, respectively. The gene product of ORF258 is homologous to members of the ATP-binding cassette-type permeases. ORF191 and ptsN are homologous to conserved ORFs found downstream from rpoN genes in other bacterial species. Unlike in most other microorganisms, rpoN and ORF191 are separated by approximately 1.6 kb. The R. etli rpoN gene was shown to control in free-living conditions the production of melanin, the activation of nifH, and the metabolism of C4-dicarboxylic acids and several nitrogen sources (ammonium, nitrate, alanine, and serine). Expression of the rpoN gene was negatively autoregulated and occurred independently of the nitrogen source. Inactivation of the ptsN gene resulted in a decrease of melanin synthesis and nifH expression. In a search for additional genes controlling the synthesis of melanin, an R. etli mutant carrying a Tn5 insertion in ptsA, a gene homologous to the Escherichia coli gene coding for enzyme I of the phosphoenolpyruvate:sugar phosphotransferase system, was obtained. The R. etli ptsA mutant also displayed reduced expression of nifH. The ptsN and ptsA mutants also displayed increased sensitivity to the toxic effects of malate and succinate. Growth of both mutants was inhibited by these C4-dicarboxylates at 20 mM at pH 7.0, while wild-type cells grow normally under these conditions. The effect of malate occurred independently of the nitrogen source used. Growth inhibition was decreased by lowering the pH of the growth medium. These results suggest that ptsN and ptsA are part of the same regulatory cascade, the inactivation of which renders the cells sensitive to toxic effects of elevated concentrations of

  2. OECD Nuclear Energy Agency activities on PTS evaluation

    International Nuclear Information System (INIS)

    Miller, A.

    1997-01-01

    The Safety Division of the OECD Nuclear Energy Agency provides the secretariat for the Committee on the Safety of Nuclear Installations (CSNI), which deals with technological aspects, and for the Committee for Nuclear Regulatory Activities (CNRA) dealing with regulatory aspects. Under these committees, activities are carried out through five Principal Working Groups (PWGs). The relevant group for PTS is PWG-3 on the integrity of structures and components. There is also PWG-2 on coolant system behavior, but the thermal hydraulic aspects of PTS have not been considered by PWG-2. PWG-3 carries out it work in a similar manner to the IAEA IWG LMNPP, by preparing reports and organizing round robins, Specialists Meetings and Workshops. The general context of RPV PTS has been considered in several workshops: on the 'Complementary roles of Fracture Mechanics and Non-Destructive Examination in the Safety Assessment of Components' in Wuerenlingen in 1988; on the 'Safety Assessment of RPVs' in Espoo in 1990; and on 'Fracture Mechanics Verification by Large Scale Testing' (joint with IAEA) at Oak Ridge in 1992. Activities specific to PTS have been an international survey on regulatory practices on PTS carried out in 1991, and a series of fracture round robins addressing PTS conditions organized by GRS in Germany and ORNL in the USA. 3 refs, 5 tabs

  3. OECD Nuclear Energy Agency activities on PTS evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Miller, A [NEA Nuclear Safety Div., Issy-les-Moulineaux (France)

    1997-09-01

    The Safety Division of the OECD Nuclear Energy Agency provides the secretariat for the Committee on the Safety of Nuclear Installations (CSNI), which deals with technological aspects, and for the Committee for Nuclear Regulatory Activities (CNRA) dealing with regulatory aspects. Under these committees, activities are carried out through five Principal Working Groups (PWGs). The relevant group for PTS is PWG-3 on the integrity of structures and components. There is also PWG-2 on coolant system behavior, but the thermal hydraulic aspects of PTS have not been considered by PWG-2. PWG-3 carries out it work in a similar manner to the IAEA IWG LMNPP, by preparing reports and organizing round robins, Specialists Meetings and Workshops. The general context of RPV PTS has been considered in several workshops: on the `Complementary roles of Fracture Mechanics and Non-Destructive Examination in the Safety Assessment of Components` in Wuerenlingen in 1988; on the `Safety Assessment of RPVs` in Espoo in 1990; and on `Fracture Mechanics Verification by Large Scale Testing` (joint with IAEA) at Oak Ridge in 1992. Activities specific to PTS have been an international survey on regulatory practices on PTS carried out in 1991, and a series of fracture round robins addressing PTS conditions organized by GRS in Germany and ORNL in the USA. 3 refs, 5 tabs.

  4. Cell-Type-Specific Splicing of Piezo2 Regulates Mechanotransduction

    Directory of Open Access Journals (Sweden)

    Marcin Szczot

    2017-12-01

    Full Text Available Summary: Piezo2 is a mechanically activated ion channel required for touch discrimination, vibration detection, and proprioception. Here, we discovered that Piezo2 is extensively spliced, producing different Piezo2 isoforms with distinct properties. Sensory neurons from both mice and humans express a large repertoire of Piezo2 variants, whereas non-neuronal tissues express predominantly a single isoform. Notably, even within sensory ganglia, we demonstrate the splicing of Piezo2 to be cell type specific. Biophysical characterization revealed substantial differences in ion permeability, sensitivity to calcium modulation, and inactivation kinetics among Piezo2 splice variants. Together, our results describe, at the molecular level, a potential mechanism by which transduction is tuned, permitting the detection of a variety of mechanosensory stimuli. : Szczot et al. find that the mechanoreceptor Piezo2 is extensively alternatively spliced, generating multiple distinct isoforms. Their findings indicate that these splice products have specific tissue and cell type expression patterns and exhibit differences in receptor properties. Keywords: Piezo, touch, sensation, ion-channel, splicing

  5. Piezo proteins are pore-forming subunits of mechanically activated channels.

    Science.gov (United States)

    Coste, Bertrand; Xiao, Bailong; Santos, Jose S; Syeda, Ruhma; Grandl, Jörg; Spencer, Kathryn S; Kim, Sung Eun; Schmidt, Manuela; Mathur, Jayanti; Dubin, Adrienne E; Montal, Mauricio; Patapoutian, Ardem

    2012-02-19

    Mechanotransduction has an important role in physiology. Biological processes including sensing touch and sound waves require as-yet-unidentified cation channels that detect pressure. Mouse Piezo1 (MmPiezo1) and MmPiezo2 (also called Fam38a and Fam38b, respectively) induce mechanically activated cationic currents in cells; however, it is unknown whether Piezo proteins are pore-forming ion channels or modulate ion channels. Here we show that Drosophila melanogaster Piezo (DmPiezo, also called CG8486) also induces mechanically activated currents in cells, but through channels with remarkably distinct pore properties including sensitivity to the pore blocker ruthenium red and single channel conductances. MmPiezo1 assembles as a ∼1.2-million-dalton homo-oligomer, with no evidence of other proteins in this complex. Purified MmPiezo1 reconstituted into asymmetric lipid bilayers and liposomes forms ruthenium-red-sensitive ion channels. These data demonstrate that Piezo proteins are an evolutionarily conserved ion channel family involved in mechanotransduction.

  6. Analytical design model for a piezo-composite unimorph actuator and its verification using lightweight piezo-composite curved actuators

    Science.gov (United States)

    Yoon, K. J.; Park, K. H.; Lee, S. K.; Goo, N. S.; Park, H. C.

    2004-06-01

    This paper describes an analytical design model for a layered piezo-composite unimorph actuator and its numerical and experimental verification using a LIPCA (lightweight piezo-composite curved actuator) that is lighter than other conventional piezo-composite type actuators. The LIPCA is composed of top fiber composite layers with high modulus and low CTE (coefficient of thermal expansion), a middle PZT ceramic wafer, and base layers with low modulus and high CTE. The advantages of the LIPCA design are to replace the heavy metal layer of THUNDER by lightweight fiber-reinforced plastic layers without compromising the generation of high force and large displacement and to have design flexibility by selecting the fiber direction and the number of prepreg layers. In addition to the lightweight advantage and design flexibility, the proposed device can be manufactured without adhesive layers when we use a resin prepreg system. A piezo-actuation model for a laminate with piezo-electric material layers and fiber composite layers is proposed to predict the curvature and residual stress of the LIPCA. To predict the actuation displacement of the LIPCA with curvature, a finite element analysis method using the proposed piezo-actuation model is introduced. The predicted deformations are in good agreement with the experimental ones.

  7. Piezo1 regulates mechanotransductive release of ATP from human RBCs.

    Science.gov (United States)

    Cinar, Eyup; Zhou, Sitong; DeCourcey, James; Wang, Yixuan; Waugh, Richard E; Wan, Jiandi

    2015-09-22

    Piezo proteins (Piezo1 and Piezo2) are recently identified mechanically activated cation channels in eukaryotic cells and associated with physiological responses to touch, pressure, and stretch. In particular, human RBCs express Piezo1 on their membranes, and mutations of Piezo1 have been linked to hereditary xerocytosis. To date, however, physiological functions of Piezo1 on normal RBCs remain poorly understood. Here, we show that Piezo1 regulates mechanotransductive release of ATP from human RBCs by controlling the shear-induced calcium (Ca(2+)) influx. We find that, in human RBCs treated with Piezo1 inhibitors or having mutant Piezo1 channels, the amounts of shear-induced ATP release and Ca(2+) influx decrease significantly. Remarkably, a critical extracellular Ca(2+) concentration is required to trigger significant ATP release, but membrane-associated ATP pools in RBCs also contribute to the release of ATP. Our results show how Piezo1 channels are likely to function in normal RBCs and suggest a previously unidentified mechanotransductive pathway in ATP release. Thus, we anticipate that the study will impact broadly on the research of red cells, cellular mechanosensing, and clinical studies related to red cell disorders and vascular disease.

  8. Pressurized Thermal Shock, Pts

    International Nuclear Information System (INIS)

    Boyd, C.

    2008-01-01

    Pressurized Thermal Shock (Pts) refers to a condition that challenges the integrity of the reactor pressure vessel. The root cause of this problem is the radiation embrittlement of the reactor vessel. This embrittlement leads to an increase in the reference temperature for nil ductility transition (RTNDT). RTNDT can increase to the point where the reactor vessel material can loose fracture toughness during overcooling events. The analysis of the risk of having a Pts for a specific plant is a multi-disciplinary problem involving probabilistic risk analysis (PRA), thermal-hydraulic analysis, and ultimately a structural and fracture analysis of the vessel wall. The PRA effort involves the postulation of overcooling events and ultimately leads to an integrated risk analysis. The thermal-hydraulic effort involves the difficult task of predicting the system behavior during a postulated overcooling scenario with a special emphasis on predicting the thermal and mechanic loadings on the reactor pressure vessel wall. The structural and fracture analysis of the reactor vessel wall relies on the thermal-hydraulic conditions as boundary conditions. The US experience has indicated that medium and large diameter primary system breaks dominate the risk of Pts along with scenarios that involve a stuck open valve (and associated system cooldown) that recloses resulting in system re-pressurization while the vessel wall is cool.

  9. Procurement Tracking System (PTS)

    Data.gov (United States)

    Office of Personnel Management — The Procurement Tracking System (PTS) is used solely by the procurement staff of the Office of the Inspector General (OIG) at the U.S. Office of Personnel Management...

  10. A protein interaction mechanism for suppressing the mechanosensitive Piezo channels.

    Science.gov (United States)

    Zhang, Tingxin; Chi, Shaopeng; Jiang, Fan; Zhao, Qiancheng; Xiao, Bailong

    2017-11-27

    Piezo proteins are bona fide mammalian mechanotransduction channels for various cell types including endothelial cells. The mouse Piezo1 of 2547 residues forms a three-bladed, propeller-like homo-trimer comprising a central pore-module and three propeller-structures that might serve as mechanotransduction-modules. However, the mechanogating and regulation of Piezo channels remain unclear. Here we identify the sarcoplasmic /endoplasmic-reticulum Ca 2+ ATPase (SERCA), including the widely expressed SERCA2, as Piezo interacting proteins. SERCA2 strategically suppresses Piezo1 via acting on a 14-residue-constituted intracellular linker connecting the pore-module and mechanotransduction-module. Mutating the linker impairs mechanogating and SERCA2-mediated modulation of Piezo1. Furthermore, the synthetic linker-peptide disrupts the modulatory effects of SERCA2, demonstrating the key role of the linker in mechanogating and regulation. Importantly, the SERCA2-mediated regulation affects Piezo1-dependent migration of endothelial cells. Collectively, we identify SERCA-mediated regulation of Piezos and the functional significance of the linker, providing important insights into the mechanogating and regulation mechanisms of Piezo channels.

  11. Multipacting Simulations of Tuner-adjustable waveguide coupler (TaCo) with CST

    CERN Document Server

    Shafqat, Nuaman; Wegner, Rolf

    2015-01-01

    Tuner-adjustable waveguide couplers (TaCo) are used to feed microwave power to different RF structures of LINAC4. This paper studies the multipacting phenomenon for TaCo using PIC solver of CST PS. Simulations are performed for complete field sweeps and results are analysed.

  12. Integration of piezo-capacitive and piezo-electric nanoweb based pressure sensors for imaging of static and dynamic pressure distribution.

    Science.gov (United States)

    Jeong, Y J; Oh, T I; Woo, E J; Kim, K J

    2017-07-01

    Recently, highly flexible and soft pressure distribution imaging sensor is in great demand for tactile sensing, gait analysis, ubiquitous life-care based on activity recognition, and therapeutics. In this study, we integrate the piezo-capacitive and piezo-electric nanowebs with the conductive fabric sheets for detecting static and dynamic pressure distributions on a large sensing area. Electrical impedance tomography (EIT) and electric source imaging are applied for reconstructing pressure distribution images from measured current-voltage data on the boundary of the hybrid fabric sensor. We evaluated the piezo-capacitive nanoweb sensor, piezo-electric nanoweb sensor, and hybrid fabric sensor. The results show the feasibility of static and dynamic pressure distribution imaging from the boundary measurements of the fabric sensors.

  13. Mechanosensitive Channels: In Touch with Piezo

    OpenAIRE

    Xiao, Rui; Xu, X.Z. Shawn

    2010-01-01

    Mechanosensory transduction underlies touch, hearing and proprioception and requires mechanosensitive channels that are directly gated by forces; however, the molecular identities of these channels remain largely elusive. A new study has identified Piezo1 and Piezo2 as a novel class of mechanosensitive channels.

  14. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  15. A prototype superconducting cavity for TRISTAN

    International Nuclear Information System (INIS)

    Furuya, T.; Hara, K.; Hosoyama, K.

    1987-01-01

    Following the feasibility study on the 3-cell superconducting cavity in the TRISTAN Accumulation Ring (TAR), a 5-cell 508 MHz Nb cavity was constructed and tested in the TAR. The cavity was equipped with a RF input coupler on a beam pipe, two HOM couplers on the other beam pipe and two additional HOM couplers on the equator of an end cell. The maximum accelerating field (Eaxx) was 4.5 MV/m with a Q value of about 1x10 9 at 4.2 deg K. The field was limited by the electron field emission and neither electron multipacting nor breakdown caused by couplers was observed. Damping of the HOM was sufficient and the input coupler was tested up to 82 KW in total reflection. A frequency tuning system consisted of two piezo electric and mechanical tuners. The piezo tuner was fast enough and the mechanical tuner covered wide range. In the beam test, the single bunch electron current of 29 mA was captured by the superconducting cavity alone and 13 mA was accelerated to 4.8 GeV. The maximum power transferred to the beam was 26 KW. The refrigeration system worked very stably

  16. CEBAF NEW DIGITAL LLRF SYSTEM EXTENDED FUNCTIONALITY

    International Nuclear Information System (INIS)

    T. Allison; K. Davis; H. Dong; C. Hovater; L. King; J. Musson; T. Plawski

    2007-01-01

    The new digital LLRF system for the CEBAF 12GeV accelerator will perform a variety of tasks, beyond field control [1]. In this paper we present the superconducting cavity resonance control system designed to minimize RF power during gradient ramp and to minimize RF power during steady state operation. Based on the calculated detuning angle, which represents the difference between reference and cavity resonance frequency, the cavity length will be adjusted with a mechanical tuner. The tuner has two mechanical driving devices, a stepper motor and a piezo-tuner, to yield a combination of coarse and fine control. Although LLRF piezo processing speed can achieve 10 kHz bandwidth, only 10 Hz speed is needed for 12 GeV upgrade. There will be a number of additional functions within the LLRF system; heater controls to maintain cryomodule's heat load balance, ceramic window temperature monitoring, waveguide vacuum interlocks, ARC detector interlock and quench detection. The additional functions will be divided between the digital board, incorporating an Altera FPGA and an embedded EPICS IOC. This paper will also address hardware evolution and test results performed with different SC cavities

  17. Progress in piezo-phototronic effect modulated photovoltaics.

    Science.gov (United States)

    Que, Miaoling; Zhou, Ranran; Wang, Xiandi; Yuan, Zuqing; Hu, Guofeng; Pan, Caofeng

    2016-11-02

    Wurtzite structured materials, like ZnO, GaN, CdS, and InN, simultaneously possess semiconductor and piezoelectric properties. The inner-crystal piezopotential induced by external strain can effectively tune/control the carrier generation, transport and separation/combination processes at the metal-semiconductor contact or p-n junction, which is called the piezo-phototronic effect. This effect can efficiently enhance the performance of photovoltaic devices based on piezoelectric semiconductor materials by utilizing the piezo-polarization charges at the junction induced by straining, which can modulate the energy band of the piezoelectric material and then accelerate or prevent the separation process of the photon-generated electrons and vacancies. This paper introduces the fundamental physics principles of the piezo-phototronic effect, and reviews recent progress in piezo-phototronic effect enhanced solar cells, including solar cells based on semiconductor nanowire, organic/inorganic materials, quantum dots, and perovskite. The piezo-phototronic effect is suggested as a suitable basis for the development of an innovative method to enhance the performance of solar cells based on piezoelectric semiconductors by applied extrinsic strains, which might be appropriate for fundamental research and potential applications in various areas of optoelectronics.

  18. Piezo-generator integrating a vertical array of GaN nanowires.

    Science.gov (United States)

    Jamond, N; Chrétien, P; Houzé, F; Lu, L; Largeau, L; Maugain, O; Travers, L; Harmand, J C; Glas, F; Lefeuvre, E; Tchernycheva, M; Gogneau, N

    2016-08-12

    We demonstrate the first piezo-generator integrating a vertical array of GaN nanowires (NWs). We perform a systematic multi-scale analysis, going from single wire properties to macroscopic device fabrication and characterization, which allows us to establish for GaN NWs the relationship between the material properties and the piezo-generation, and to propose an efficient piezo-generator design. The piezo-conversion of individual MBE-grown p-doped GaN NWs in a dense array is assessed by atomic force microscopy (AFM) equipped with a Resiscope module yielding an average output voltage of 228 ± 120 mV and a maximum value of 350 mV generated per NW. In the case of p-doped GaN NWs, the piezo-generation is achieved when a positive piezo-potential is created inside the nanostructures, i.e. when the NWs are submitted to compressive deformation. The understanding of the piezo-generation mechanism in our GaN NWs, gained from AFM analyses, is applied to design a piezo-generator operated under compressive strain. The device consists of NW arrays of several square millimeters in size embedded into spin-on glass with a Schottky contact for rectification and collection of piezo-generated carriers. The generator delivers a maximum power density of ∼12.7 mW cm(-3). This value sets the new state of the art for piezo-generators based on GaN NWs and more generally on nitride NWs, and offers promising prospects for the use of GaN NWs as high-efficiency ultra-compact energy harvesters.

  19. Piezo-optic surfaces of lithium niobate crystals

    International Nuclear Information System (INIS)

    Mytsyk, B. G.; Dem'yanyshyn, N. M.

    2006-01-01

    A method of construction of the spatial distribution of the piezo-optic effect in crystals is proposed. A particular case of this method is the known technique of construction of indicator surfaces of the piezo-optic effect. The essence of the proposed method consists in determining the difference in the radius vectors of the optical indicatrix perturbed by stress and the free optical indicatrix. It is shown that this difference in the radius vectors is mathematically identical to the law of transformation of the piezo-optic tensor during the rotation of the coordinate system

  20. Performance and Mechanism of Piezo-Catalytic Degradation of 4-Chlorophenol: Finding of Effective Piezo-Dechlorination.

    Science.gov (United States)

    Lan, Shenyu; Feng, Jinxi; Xiong, Ya; Tian, Shuanghong; Liu, Shengwei; Kong, Lingjun

    2017-06-06

    Piezo-catalysis was first used to degrade a nondye pollutant, 4-chlorophenol (4-CP). In this process, hydrothermally synthesized tetragonal BaTiO 3 nano/micrometer-sized particles were used as the piezo-catalyst, and the ultrasonic irradiation with low frequency was selected as the vibration energy to cause the deformation of tetragonal BaTiO 3 . It was found that the piezoelectric potential from the deformation could not only successfully degrade 4-chlorophenol but also effectively dechlorinate it at the same time, and five kinds of dechlorinated intermediates, hydroquinone, benzoquinone, phenol, cyclohexanone, and cyclohexanol, were determined. This is the first sample of piezo-dechlorination. Although various active species, including h + , e - , •H, •OH, •O 2 - , 1 O 2 , and H 2 O 2 , were generated in the piezoelectric process, it was confirmed by ESR, scavenger studies, and LC-MS that the degradation and dechlorination were mainly attributed to •OH radicals. These •OH radicals were chiefly derived from the electron reduction of O 2 , partly from the hole oxidation of H 2 O. These results indicated that the piezo-catalysis was an emerging and effective advanced oxidation technology for degradation and dechlorination of organic pollutants.

  1. Optimal Tuner Selection for Kalman Filter-Based Aircraft Engine Performance Estimation

    Science.gov (United States)

    Simon, Donald L.; Garg, Sanjay

    2010-01-01

    A linear point design methodology for minimizing the error in on-line Kalman filter-based aircraft engine performance estimation applications is presented. This technique specifically addresses the underdetermined estimation problem, where there are more unknown parameters than available sensor measurements. A systematic approach is applied to produce a model tuning parameter vector of appropriate dimension to enable estimation by a Kalman filter, while minimizing the estimation error in the parameters of interest. Tuning parameter selection is performed using a multi-variable iterative search routine which seeks to minimize the theoretical mean-squared estimation error. This paper derives theoretical Kalman filter estimation error bias and variance values at steady-state operating conditions, and presents the tuner selection routine applied to minimize these values. Results from the application of the technique to an aircraft engine simulation are presented and compared to the conventional approach of tuner selection. Experimental simulation results are found to be in agreement with theoretical predictions. The new methodology is shown to yield a significant improvement in on-line engine performance estimation accuracy

  2. Overcooling transient selection and thermal hydraulic analyses of the Loviisa PTS assessments

    Energy Technology Data Exchange (ETDEWEB)

    Tuomisto, H [IVO Power Engineering Ltd, Vantaa (Finland)

    1997-09-01

    This paper describes transients selection and thermal hydraulic analyses of various PTS assessment studies performed for the pressure vessels of the Loviisa WWER-reactors. Deterministic analyses have been performed in various stages of the PTS studies and they have always made the formal basis for design and licensing of the reactor pressure vessel. The integrated, probabilistic PTS study was carried out to give an overview of the severity of all different PTS sequences, and give a quantitative estimate of the importance of the PTS issues in relation to the overall safety of the plant. Later, the sequences including external flooding of the pressure vessels were added to the PTS assessment. Thermal recovery annealing of the Loviisa 1 reactor pressure vessel took place during refuelling outage in 1996. (author). 10 refs, 4 figs, 3 tabs.

  3. Role of Piezo Channels in Ultrasound-stimulated Dental Stem Cells.

    Science.gov (United States)

    Gao, Qianhua; Cooper, Paul R; Walmsley, A Damien; Scheven, Ben A

    2017-07-01

    Piezo1 and Piezo2 are mechanosensitive membrane ion channels. We hypothesized that Piezo proteins may play a role in transducing ultrasound-associated mechanical signals and activate downstream mitogen-activated protein kinase (MAPK) signaling processes in dental cells. In this study, the expression and role of Piezo channels were investigated in dental pulp stem cells (DPSCs) and periodontal ligament stem cells (PDLSCs) after treatment with low-intensity pulsed ultrasound (LIPUS). Cell proliferation was evaluated by bromodeoxyuridine incorporation. Western blots were used to analyze the proliferating cell nuclear antigen as well as the transcription factors c-fos and c-jun. Enzyme-linked immunosorbent assay and Western blotting were used to determine the activation of MAPK after LIPUS treatment. Ruthenium red (RR), a Piezo ion channel blocker, was applied to determine the functional role of Piezo proteins in LIPUS-stimulated cell proliferation and MAPK signaling. Western blotting showed the presence of Piezo1 and Piezo2 in both dental cell types. LIPUS treatment significantly increased the level of the Piezo proteins in DPSCs after 24 hours; however, no significant effects were observed in PDLSCs. Treatment with RR significantly inhibited LIPUS-stimulated DPSC proliferation but not PDLSC proliferation. Extracellular signal-related kinase (ERK) 1/2 MAPK was consistently activated in DPSCs over a 24-hour time period after LIPUS exposure, whereas phosphorylated c-Jun N-terminal kinase and p38 mitogen-activated protein kinase MAPK were mainly increased in PDLSCs. RR affected MAPK signaling in both dental cell types with its most prominent effects on ERK1/2/MAPK phosphorylation levels; the significant inhibition of LIPUS-induced stimulation of ERK1/2 activation in DPSCs by RR suggests that stimulation of DPSC proliferation by LIPUS involves Piezo-mediated regulation of ERK1/2 MAPK signaling. This study for the first time supports the role of Piezo ion channels in

  4. Piezo-Phototronic Matrix via a Nanowire Array.

    Science.gov (United States)

    Zhang, Yang; Zhai, Junyi; Wang, Zhong Lin

    2017-12-01

    Piezoelectric semiconductors, such as ZnO and GaN, demonstrate multiproperty coupling effects toward various aspects of mechanical, electrical, and optical excitation. In particular, the three-way coupling among semiconducting, photoexcitation, and piezoelectric characteristics in wurtzite-structured semiconductors is established as a new field, which was first coined as piezo-phototronics by Wang in 2010. The piezo-phototronic effect can controllably modulate the charge-carrier generation, separation, transport, and/or recombination in optical-electronic processes by modifying the band structure at the metal-semiconductor or semiconductor-semiconductor heterojunction/interface. Here, the progress made in using the piezo-phototronic effect for enhancing photodetectors, pressure sensors, light-emitting diodes, and solar cells is reviewed. In comparison with previous works on a single piezoelectric semiconducting nanowire, piezo-phototronic nanodevices built using nanowire arrays provide a promising platform for fabricating integrated optoelectronics with the realization of high-spatial-resolution imaging and fast responsivity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  6. Current pulse shaping of the load current on PTS

    Directory of Open Access Journals (Sweden)

    Minghe Xia

    2016-02-01

    Full Text Available The typical rise time of PTS machine is ∼110 ns with about 10 MA peak current under short pulse mode when all 24 modules discharge simultaneously. By distributing the trigger times of 12 laser beams logically and adjusting the statues of the pulse output switches, longer rise-time pulse can be obtained on the PTS facility. Based on the required pulse shape, whole circuit simulations will be used to calculate the trigger times of each laser triggering gas switch and the status of the pulse output switches. The rise time of the current is determined by the time difference between the first and last trigged laser triggering gas switches. In order to trigger the laser triggering gas switch, sufficient laser power is needed to be sent into the gap of the gas switches. The gas pressure and voltage difference on the two electrodes of the gas switches also affect the triggering of the gas switches, and the voltage added on the gas switch is determined by its transition time. Traditionally the trigger time difference should be less than the transition time of the two neighboring modules. A new simulation model of PTS shows one can break this transition time limits. Series of current pulse shaping experiments have been investigated on the PTS (Primary Test Stand. As results, more than 5 MA peak current were successfully achieved on the load with a rise time of 600 ns. This study and experiments of the pulse shaping on PTS demonstrate the adaptable ability of the PTS for offering different waveform of mega ampere current pulse for different research purpose.

  7. Mechanosensitive Piezo Channels in the Gastrointestinal Tract.

    Science.gov (United States)

    Alcaino, C; Farrugia, G; Beyder, A

    2017-01-01

    Sensation of mechanical forces is critical for normal function of the gastrointestinal (GI) tract and abnormalities in mechanosensation are linked to GI pathologies. In the GI tract there are several mechanosensitive cell types-epithelial enterochromaffin cells, intrinsic and extrinsic enteric neurons, smooth muscle cells and interstitial cells of Cajal. These cells use mechanosensitive ion channels that respond to mechanical forces by altering transmembrane ionic currents in a process called mechanoelectrical coupling. Several mechanosensitive ionic conductances have been identified in the mechanosensory GI cells, ranging from mechanosensitive voltage-gated sodium and calcium channels to the mechanogated ion channels, such as the two-pore domain potassium channels K2P (TREK-1) and nonselective cation channels from the transient receptor potential family. The recently discovered Piezo channels are increasingly recognized as significant contributors to cellular mechanosensitivity. Piezo1 and Piezo2 are nonselective cationic ion channels that are directly activated by mechanical forces and have well-defined biophysical and pharmacologic properties. The role of Piezo channels in the GI epithelium is currently under investigation and their role in the smooth muscle syncytium and enteric neurons is still not known. In this review, we outline the current state of knowledge on mechanosensitive ion channels in the GI tract, with a focus on the known and potential functions of the Piezo channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. A Tour de Force: The Discovery, Properties, and Function of Piezo Channels.

    Science.gov (United States)

    Gottlieb, P A

    2017-01-01

    Mechanical transducers appear throughout cell biology and are used to convert mechanical stress into chemical or electrical signals that allow the cell to respond to environmental changes. In the past six years, a eukaryotic mechanical channel family with two members, Piezo1 and Piezo2, has been identified. Piezo1 was shown to be a cation-selective channel that does not require ancillary proteins for activity. Mouse Piezo1 is large, with over 2500 amino acids, and is not homologous to other ion channels. Both piezo channels have rapid voltage-dependent inactivation with a reversal potential near 0mV. The CryoEm structure of Piezo1 at 4.8Å shows trimer stoichiometry. Since the discovery of the piezo channels, their roles in the physiological response of cells have started to emerge. Significant progress has been made in understanding the intrinsic properties of the channels and how these properties are modulated by cytoskeletal elements. Specific diseases, such as hereditary xerocytosis affecting red blood cells, have mutations in Piezo1 that alter the cell's response to force, typically slowing inactivation and introducing a latency for activation. A number of physiological functions for piezo channels have been identified. These range from sensing the stiffness of surrounding substrate, to the response to light touch, to serotonin release from the gut. This review provides a general overview of the properties and roles of Piezo1 and Piezo2 in eukaryotic mechanotransduction. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Touch, Tension, and Transduction - The Function and Regulation of Piezo Ion Channels.

    Science.gov (United States)

    Wu, Jason; Lewis, Amanda H; Grandl, Jörg

    2017-01-01

    In 2010, two proteins, Piezo1 and Piezo2, were identified as the long-sought molecular carriers of an excitatory mechanically activated current found in many cells. This discovery has opened the floodgates for studying a vast number of mechanotransduction processes. Over the past 6 years, groundbreaking research has identified Piezos as ion channels that sense light touch, proprioception, and vascular blood flow, ruled out roles for Piezos in several other mechanotransduction processes, and revealed the basic structural and functional properties of the channel. Here, we review these findings and discuss the many aspects of Piezo function that remain mysterious, including how Piezos convert a variety of mechanical stimuli into channel activation and subsequent inactivation, and what molecules and mechanisms modulate Piezo function. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Ion Permeation and Mechanotransduction Mechanisms of Mechanosensitive Piezo Channels.

    Science.gov (United States)

    Zhao, Qiancheng; Wu, Kun; Geng, Jie; Chi, Shaopeng; Wang, Yanfeng; Zhi, Peng; Zhang, Mingmin; Xiao, Bailong

    2016-03-16

    Piezo proteins have been proposed as the long-sought-after mechanosensitive cation channels in mammals that play critical roles in various mechanotransduction processes. However, the molecular bases that underlie their ion permeation and mechanotransduction have remained functionally undefined. Here we report our finding of the miniature pore-forming module of Piezo1 that resembles the pore architecture of other trimeric channels and encodes the essential pore properties. We further identified specific residues within the pore module that determine unitary conductance, pore blockage and ion selectivity for divalent and monovalent cations and anions. The non-pore-containing region of Piezo1 confers mechanosensitivity to mechano-insensitive trimeric acid-sensing ion channels, demonstrating that Piezo1 channels possess intrinsic mechanotransduction modules separate from their pore modules. In conclusion, this is the first report on the bona fide pore module and mechanotransduction components of Piezo channels, which define their ion-conducting properties and gating by mechanical stimuli, respectively. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Patterned piezo-, pyro-, and ferroelectricity of poled polymer electrets

    International Nuclear Information System (INIS)

    Qiu, Xunlin

    2010-01-01

    Polymers with strong piezo-, pyro-, and ferroelectricity are attractive for a wide range of applications. In particular, semicrystalline ferroelectric polymers are suitable for a large variety of piezo- and pyroelectric transducers or sensors, while amorphous polymers containing chromophore molecules are particularly interesting for photonic devices. Recently, a new class of polymer materials has been added to this family: internally charged cellular space-charge polymer electrets (so-called “ferroelectrets”), whose piezoelectricity can be orders of magnitude higher than that of conventional ferroelectric polymers. Suitable patterning of these materials leads to improved or unusual macroscopic piezo-, pyro-, and ferroelectric or nonlinear optical properties that may be particularly useful for advanced transducer or waveguide applications. In the present paper, the piezo-, pyro-, and ferroelectricity of poled polymers is briefly introduced, an overview on the preparation of polymer electrets with patterned piezo-, pyro-, and ferroelectricity is provided and a survey of selected applications is presented.

  12. Progress in the Development of SRF Cavity Tuners Based on Magnetic Smart Materials

    International Nuclear Information System (INIS)

    C. Joshi; A. Pappo; D. Upham; J. Preble

    2001-01-01

    Energen, Inc. has developed and demonstrated an SRF cavity tuning mechanism based on magnetic smart materials. Magnetic ''smart'' materials change their shape in a reversible and repeatable manner when exposed to a small magnetic field. A fine-tuning mechanism with a 2 kHz tuning range on a nominal resonant frequency of 1.497 GHz. was successfully demonstrated in 1999 [1]. Since then, Energen has been developing a tuning mechanism based on its linear stepper motors. These stepper motors are designed to deliver high-force precision linear motion of tens of millimeters at cryogenic temperatures. A locking mechanism built into the stepper motor enables the tuner to be locked into position when the power is turned off. This new tuning technology will eliminate the mechanical feeds through the vacuum jacket and reduce the complexity of the cryostat design and assembly. Performance and capabilities of a prototype SRF cavity tuner will be reported

  13. Touch, Tension, and Transduction – the Function and Regulation of Piezo Ion Channels

    Science.gov (United States)

    Wu, Jason; Lewis, Amanda; Grandl, Jörg

    2016-01-01

    In 2010, two proteins, Piezo1 and Piezo2, were identified as the long-sought molecular carriers of an excitatory mechanically activated current found in many cells. This discovery has opened the floodgates for studying a vast number of mechanotransduction processes. Over the past six years, groundbreaking research has identified Piezos as ion channels that sense light touch, proprioception, and vascular blood flow, ruled out roles for Piezos in several other mechanotransduction processes, and revealed the basic structural and functional properties of the channel. Here, we review these findings and discuss the many aspects of Piezo function that remain mysterious, including how Piezos convert a variety of mechanical stimuli into channel activation and subsequent inactivation, and what molecules and mechanisms modulate Piezo function. PMID:27743844

  14. Pressurized thermal shock (PTS)

    International Nuclear Information System (INIS)

    Rosso, Ricardo D.; Ventura, Mirta A.

    2006-01-01

    In the present work, a description of Thermal Shock in Pressurized conditions (PTS), and its influence in the treatment of the integrity of the pressure vessel (RPV) of a Pressurized Water Reactor (PWR) and/or of a Heavy water Pressurized water Reactor (PHWR) is made. Generally, the analysis of PTS involves a process of three stages: a-) Modeling with a System Code of relevant thermohydraulics transients in reference with the thermal shock; b-) The local distribution of temperatures in the downcomer and the heat transference coefficients from the RPV wall to the fluid, are determined; c-) The fracture mechanical analysis. These three stages are included in this work: Results with the thermohydraulics code Relap5/mod.3, are obtained, for a LOCA scenario in the hot leg of the cooling System of the Primary System of the CAN-I reactor. The method used in obtaining results is described. A study on the basis of lumped parameters of the local evolutions of the temperature of the flow is made, in the downcomer of the reactor pressure vessel. The purpose of this study is to determine how the intensification of the stress coefficient, varies in function of the emergency injected water during the thermohydraulic transients that take place under the imposed conditions in the postulated scene. Specially, it is considered a 50 cm 2 break, located in the neighborhoods of the pressurized with the corresponding hot leg connection. This size is considered like the most critical. The method used to obtain the results is described. The fracture mechanical analysis is made. From the obtained results we confirmed that we have a simple tool of easy application in order to analyze phenomena of the type PTS in the postulated scenes by break in the cold and hot legs of the primary system. This methodology of calculus is completely independent of the used ones by the Nucleoelectrica Argentina S.A. (NASA) in the analysis of the PTS phenomena in the CAN-I. The results obtained with the adopted

  15. Improving the accuracy of walking piezo motors.

    Science.gov (United States)

    den Heijer, M; Fokkema, V; Saedi, A; Schakel, P; Rost, M J

    2014-05-01

    Many application areas require ultraprecise, stiff, and compact actuator systems with a high positioning resolution in combination with a large range as well as a high holding and pushing force. One promising solution to meet these conflicting requirements is a walking piezo motor that works with two pairs of piezo elements such that the movement is taken over by one pair, once the other pair reaches its maximum travel distance. A resolution in the pm-range can be achieved, if operating the motor within the travel range of one piezo pair. However, applying the typical walking drive signals, we measure jumps in the displacement up to 2.4 μm, when the movement is given over from one piezo pair to the other. We analyze the reason for these large jumps and propose improved drive signals. The implementation of our new drive signals reduces the jumps to less than 42 nm and makes the motor ideally suitable to operate as a coarse approach motor in an ultra-high vacuum scanning tunneling microscope. The rigidity of the motor is reflected in its high pushing force of 6.4 N.

  16. Koncepce tlačítkového piezo-generátoru

    OpenAIRE

    Kučera, David

    2012-01-01

    Tato bakalářská práce se zabývá koncepcí tlačítkového piezo-generátoru. V práci jsou popsány typy piezo-generátorů, vysvětlen piezoelektrický jev, typy piezoelektrických materiálů se zaměřením na piezokeramiku. Dále jsou popsány materiálové vlastnosti piezoelektrických keramik. Na konci práce je popsán návrh samotného tlačítkového piezo-generátoru. This bachelor’s thesis deals with proposal of piezo-generator inside button. There are described types of piezo-generators, explained piezoelec...

  17. PTS and the IAEA database

    International Nuclear Information System (INIS)

    Davies, L.M.; Gillemot, F.; Lyssakov, V.

    1997-01-01

    The International Atomic Energy Agency Data Base has been described previously at this meeting. It is the purpose of this paper to briefly describe PTS and to draw attention to the relevance of the International data base in the area of irradiation effects. 6 refs, 1 fig

  18. PTS and the IAEA database

    Energy Technology Data Exchange (ETDEWEB)

    Davies, L M [LMD Consultants, Oxford (United Kingdom); Gillemot, F [Atomic Energy Research Inst., Budapest (Hungary); Lyssakov, V [International Atomic Energy Agency, Vienna (Austria). Div. of Nuclear Power and the Fuel Cycle

    1997-09-01

    The International Atomic Energy Agency Data Base has been described previously at this meeting. It is the purpose of this paper to briefly describe PTS and to draw attention to the relevance of the International data base in the area of irradiation effects. 6 refs, 1 fig.

  19. WWER 440 integrity assessment with respect to PTS events

    International Nuclear Information System (INIS)

    Hrazsky, M.; Mikua, M.; Hermansky, P.

    1997-01-01

    The present state of art in WWER 440 RPV integrity assessment with respect to PTS events utilized in Slovakia is reviewed briefly in this paper. Recent results of some PTS's (very severe) analyses, shortly described in our paper, have confirmed the necessity of elaboration of new more sophisticated procedures again. Such methodology should be based on prepared IAEA Guidance. (author). 13 refs, 1 fig

  20. WWER 440 integrity assessment with respect to PTS events

    Energy Technology Data Exchange (ETDEWEB)

    Hrazsky, M; Mikua, M; Hermansky, P [Nuclear Power Plant Research Inst. Trnava Inc., Trnava (Slovakia)

    1997-09-01

    The present state of art in WWER 440 RPV integrity assessment with respect to PTS events utilized in Slovakia is reviewed briefly in this paper. Recent results of some PTS`s (very severe) analyses, shortly described in our paper, have confirmed the necessity of elaboration of new more sophisticated procedures again. Such methodology should be based on prepared IAEA Guidance. (author). 13 refs, 1 fig.

  1. A protein interaction mechanism for suppressing the mechanosensitive Piezo channels

    OpenAIRE

    Zhang, Tingxin; Chi, Shaopeng; Jiang, Fan; Zhao, Qiancheng; Xiao, Bailong

    2017-01-01

    Piezo proteins are bona fide mammalian mechanotransduction channels for various cell types including endothelial cells. The mouse Piezo1 of 2547 residues forms a three-bladed, propeller-like homo-trimer comprising a central pore-module and three propeller-structures that might serve as mechanotransduction-modules. However, the mechanogating and regulation of Piezo channels remain unclear. Here we identify the sarcoplasmic /endoplasmic-reticulum Ca2+ ATPase (SERCA), including the widely expres...

  2. Mechanical regulation of stem-cell differentiation by the stretch-activated Piezo channel.

    Science.gov (United States)

    He, Li; Si, Guangwei; Huang, Jiuhong; Samuel, Aravinthan D T; Perrimon, Norbert

    2018-03-01

    Somatic stem cells constantly adjust their self-renewal and lineage commitment by integrating various environmental cues to maintain tissue homeostasis. Although numerous chemical and biological signals have been identified that regulate stem-cell behaviour, whether stem cells can directly sense mechanical signals in vivo remains unclear. Here we show that mechanical stress regulates stem-cell differentiation in the adult Drosophila midgut through the stretch-activated ion channel Piezo. We find that Piezo is specifically expressed in previously unidentified enteroendocrine precursor cells, which have reduced proliferation ability and are destined to become enteroendocrine cells. Loss of Piezo activity reduces the generation of enteroendocrine cells in the adult midgut. In addition, ectopic expression of Piezo in all stem cells triggers both cell proliferation and enteroendocrine cell differentiation. Both the Piezo mutant and overexpression phenotypes can be rescued by manipulation of cytosolic Ca 2+ levels, and increases in cytosolic Ca 2+ resemble the Piezo overexpression phenotype, suggesting that Piezo functions through Ca 2+ signalling. Further studies suggest that Ca 2+ signalling promotes stem-cell proliferation and differentiation through separate pathways. Finally, Piezo is required for both mechanical activation of stem cells in a gut expansion assay and the increase of cytosolic Ca 2+ in response to direct mechanical stimulus in a gut compression assay. Thus, our study demonstrates the existence of a specific group of stem cells in the fly midgut that can directly sense mechanical signals through Piezo.

  3. Spray-controlled combustionprocess with piezo injection; Strahlgefuehrtes Brennverfahren mit Piezo-Benzineinspritzung

    Energy Technology Data Exchange (ETDEWEB)

    Schaupp, U.; Altenschmidt, F.; Bertsch, D.; Laudenbach, N. [DaimlerChrysler AG, Stuttgart (Germany)

    2007-07-01

    The novel 2nd generation injection system of Mercedes-Benz have resulted in reduced fuel consumption and lower emissions while improving the engine performance. The piezo technology is a great technical advance. The characteristic field range in which stratified charge operation is possible has been extended since the first generation of injection systems. Lower fuel consumption is achieved not only in normal traffic but also when cruising on motorways at constant speed. The advantages are noticeable not only in the test cycle but also in real operation. The piezo injection valve was not available on the market and had to be constructed, including the 200 bar high-pressure fuel injection system. The stability of the injection system and the good mixing characteristics resulted in an optimally combustible mixture at the spark plug. Apart from stability in stratified charge operation, the possibility of multiple injection also has further advantages and potentials in terms of consumption and emissions. (orig.)

  4. Summary of flow and heat transfer in RPV under PTS

    International Nuclear Information System (INIS)

    Lu Donghua; Wang Haijun; Chen Tingkuan; Luo Yushan

    2003-01-01

    PTS under loss of coolant accident (LOCA) has great effect on the safety of RPV. Many research works focusing on flow and heat transfer in RPV under PTS have been done in developed countries for many years, and a lot of results have been got both on experiment and numerical simulation. The safety of nuclear power plant is enhanced greatly by these research works. With the developing of nuclear power technology in China, RPV integration under PTS has been studied. The author summarizes research works at home and abroad in recent years. The problems existed in present work and research direction in the future are discussed

  5. Multipacting Simulations of Tuner-adjustable waveguide coupler (TaCo) with CST Particle Studio®

    CERN Document Server

    Shafqat, N; Wegner, R

    2014-01-01

    Tuner-adjustable waveguide couplers (TaCo) are used to feed microwave power to different RF structures of LINAC4. This paper studies the multipacting phenomenon for TaCo using the PIC solver of CST PS. Simulations are performed for complete field sweeps and results are analysed.

  6. A universal piezo-driven ultrasonic cell microinjection system.

    Science.gov (United States)

    Huang, Haibo; Mills, James K; Lu, Cong; Sun, Dong

    2011-08-01

    Over the past decade, the rapid development of biotechnologies such as gene injection, in-vitro fertilization, intracytoplasmic sperm injection (ICSI) and drug development have led to great demand for highly automated, high precision equipment for microinjection. Recently a new cell injection technology using piezo-driven pipettes with a very small mercury column was proposed and successfully applied in ICSI to a variety of mammal species. Although this technique significantly improves the survival rates of the ICSI process, shortcomings due to the toxicity of mercury and damage to the cell membrane due to large lateral tip oscillations of the injector pipette may limit its application. In this paper, a new cell injection system for automatic batch injection of suspended cells is developed. A new design of the piezo-driven cell injector is proposed for automated suspended cell injection. This new piezo-driven cell injector design relocates the piezo oscillation actuator to the injector pipette which eliminates the vibration effect on other parts of the micromanipulator. A small piezo stack is sufficient to perform the cell injection process. Harmful lateral tip oscillations of the injector pipette are reduced substantially without the use of a mercury column. Furthermore, ultrasonic vibration micro-dissection (UVM) theory is utilized to analyze the piezo-driven cell injection process, and the source of the lateral oscillations of the injector pipette is investigated. From preliminary experiments of cell injection of a large number of zebrafish embryos (n = 200), the injector pipette can easily pierce through the cell membrane at a low injection speed and almost no deformation of the cell wall, and with a high success rate(96%) and survival rate(80.7%) This new injection approach shows good potential for precision injection with less damage to the injected cells.

  7. Piezo2: A Candidate Biomarker for Visceral Hypersensitivity in Irritable Bowel Syndrome?

    OpenAIRE

    Bai, Tao; Li, Ying; Xia, Jing; Jiang, Yudong; Zhang, Lei; Wang, Huan; Qian, Wei; Song, Jun; Hou, Xiaohua

    2017-01-01

    Background/Aims Currently, there exists no biomarker for visceral hypersensitivity in irritable bowel syndrome (IBS). Piezo proteins have been proven to play an important role in the mechanical stimulation to induce visceral pain in other tissues and may also be a biomarker candidate. The aim of this study was to test the expressions of Piezo1 and Piezo2 proteins in the intestinal epithelial cells from different intestinal segments and to explore the correlation between Piezo proteins express...

  8. The Development of Piezo-Driven Tools for Cellular Piercing

    Directory of Open Access Journals (Sweden)

    Changhai Ru

    2016-10-01

    Full Text Available Conventionally, intracytoplasmic sperm injection (ICSI in the mouse is conducted with piezo-drills that use a droplet of mercury for damping. The use of mercury causes concerns of toxicity and contamination. Although Fluorinert can be used as a substitute for mercury to reduce piezo-drill’s lateral vibration, the damping effect is not as satisfactory as mercury. In this work, a modified piezo-drill without using mercury was developed for the cellular piercing of mouse oocytes. Experimentally, appropriate parameters of driving voltage and frequency were obtained for the penetration of the zona pellucida of mouse oocytes. Furthermore, the lateral vibration of the injection pipette is lower than 1 μm in deionized water, which is not observable at 400 magnificence. With the piezo-drill without using mercury, the system performs the cellular piercing of mouse oocytes with a maximum cleavage rate of 94.7% (n = 117.

  9. Mechanism of piezo - and pyroelectricity of poly (vinylidene fluoride) electret

    International Nuclear Information System (INIS)

    Wada, Y.

    1980-01-01

    Basic concepts of the piezo - and pyroelectricity theory of polymer electrets are given. The origins of these effects are presented. The piezo - and pyroelectric constants are numerically obtained. (L.C.) [pt

  10. Piezo Proteins: Regulators of Mechanosensation and Other Cellular Processes*

    Science.gov (United States)

    Bagriantsev, Sviatoslav N.; Gracheva, Elena O.; Gallagher, Patrick G.

    2014-01-01

    Piezo proteins have recently been identified as ion channels mediating mechanosensory transduction in mammalian cells. Characterization of these channels has yielded important insights into mechanisms of somatosensation, as well as other mechano-associated biologic processes such as sensing of shear stress, particularly in the vasculature, and regulation of urine flow and bladder distention. Other roles for Piezo proteins have emerged, some unexpected, including participation in cellular development, volume regulation, cellular migration, proliferation, and elongation. Mutations in human Piezo proteins have been associated with a variety of disorders including hereditary xerocytosis and several syndromes with muscular contracture as a prominent feature. PMID:25305018

  11. Role of Piezo Channels in Joint Health and Injury.

    Science.gov (United States)

    Lee, W; Guilak, F; Liedtke, W

    2017-01-01

    Cartilage is an intrinsically mechanically sensitive tissue composed of chondrocytes as the only cell type. Chondrocyte mechanotransduction is not well understood, but recently we identified critical components of the mechanotransduction machinery demonstrating how mechanical stimulation of these cells can be converted into cellular calcium signals. Physiologic mechanical cues induce anabolic responses of (post-mitotic) chondrocytes via transient receptor potential vanilloid 4 ion channels, whereas injurious mechanical stress is transduced by Piezo1 jointly with Piezo2 ion channels. This chapter sheds light on the latter discovery and provides a rationale for follow-up questions, such as the nature of interaction between Piezo1 and Piezo2, and their tethering to the cytoskeleton. These recent insights can be leveraged toward translational medical progress to benefit diagnosis and treatment of osteoarthritis, representing a large and growing unmet medical need in the United States and large parts of the world. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Modeling startup and shutdown transient of the microlinear piezo drive via ANSYS

    Science.gov (United States)

    Azin, A. V.; Bogdanov, E. P.; Rikkonen, S. V.; Ponomarev, S. V.; Khramtsov, A. M.

    2017-02-01

    The article describes the construction-design of the micro linear piezo drive intended for a peripheral cord tensioner in the reflecting surface shape regulator system for large-sized transformable spacecraft antenna reflectors. The research target -the development method of modeling startup and shutdown transient of the micro linear piezo drive. This method is based on application software package ANSYS. The method embraces a detailed description of the calculation stages to determine the operating characteristics of the designed piezo drive. Based on the numerical solutions, the time characteristics of the designed piezo drive are determined.

  13. The relevance of the non-canonical PTS1 of peroxisomal catalase

    NARCIS (Netherlands)

    Williams, Chris; Aksam, Eda Bener; Gunkel, Katja; Veenhuis, Marten; van der Klei, Ida J.

    Catalase is sorted to peroxisomes via a C-terminal peroxisomal targeting signal 1 (PTS1), which binds to the receptor protein Pex5. Analysis of the C-terminal sequences of peroxisomal catalases from various species indicated that catalase never contains the typical C-terminal PTS1 tripeptide-SKL,

  14. The plant PTS1 receptor : similarities and differences to its human and yeast counterparts

    NARCIS (Netherlands)

    Wimmer, C; Schmid, Markus; Veenhuis, M; Gietl, C

    1998-01-01

    Two targeting signals, PTS1 and PTS2, mediate import of proteins into the peroxisomal matrix. We have cloned and sequenced the watermelon (Citrullus vulgaris) cDNA homologue to the PTS1 receptor gene (PEX5). Its gene product, CvPex5p, belongs to the family of tetratricopeptide repeat (TPR)

  15. The role of Drosophila Piezo in mechanical nociception.

    Science.gov (United States)

    Kim, Sung Eun; Coste, Bertrand; Chadha, Abhishek; Cook, Boaz; Patapoutian, Ardem

    2012-02-19

    Transduction of mechanical stimuli by receptor cells is essential for senses such as hearing, touch and pain. Ion channels have a role in neuronal mechanotransduction in invertebrates; however, functional conservation of these ion channels in mammalian mechanotransduction is not observed. For example, no mechanoreceptor potential C (NOMPC), a member of transient receptor potential (TRP) ion channel family, acts as a mechanotransducer in Drosophila melanogaster and Caenorhabditis elegans; however, it has no orthologues in mammals. Degenerin/epithelial sodium channel (DEG/ENaC) family members are mechanotransducers in C. elegans and potentially in D. melanogaster; however, a direct role of its mammalian homologues in sensing mechanical force has not been shown. Recently, Piezo1 (also known as Fam38a) and Piezo2 (also known as Fam38b) were identified as components of mechanically activated channels in mammals. The Piezo family are evolutionarily conserved transmembrane proteins. It is unknown whether they function in mechanical sensing in vivo and, if they do, which mechanosensory modalities they mediate. Here we study the physiological role of the single Piezo member in D. melanogaster (Dmpiezo; also known as CG8486). Dmpiezo expression in human cells induces mechanically activated currents, similar to its mammalian counterparts. Behavioural responses to noxious mechanical stimuli were severely reduced in Dmpiezo knockout larvae, whereas responses to another noxious stimulus or touch were not affected. Knocking down Dmpiezo in sensory neurons that mediate nociception and express the DEG/ENaC ion channel pickpocket (ppk) was sufficient to impair responses to noxious mechanical stimuli. Furthermore, expression of Dmpiezo in these same neurons rescued the phenotype of the constitutive Dmpiezo knockout larvae. Accordingly, electrophysiological recordings from ppk-positive neurons revealed a Dmpiezo-dependent, mechanically activated current. Finally, we found that Dmpiezo

  16. A Microfluidic Approach for Studying Piezo Channels.

    Science.gov (United States)

    Maneshi, M M; Gottlieb, P A; Hua, S Z

    2017-01-01

    Microfluidics is an interdisciplinary field intersecting many areas in engineering. Utilizing a combination of physics, chemistry, biology, and biotechnology, along with practical applications for designing devices that use low volumes of fluids to achieve high-throughput screening, is a major goal in microfluidics. Microfluidic approaches allow the study of cells growth and differentiation using a variety of conditions including control of fluid flow that generates shear stress. Recently, Piezo1 channels were shown to respond to fluid shear stress and are crucial for vascular development. This channel is ideal for studying fluid shear stress applied to cells using microfluidic devices. We have developed an approach that allows us to analyze the role of Piezo channels on any given cell and serves as a high-throughput screen for drug discovery. We show that this approach can provide detailed information about the inhibitors of Piezo channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The “In-House Agency Work” in the PTS and the Union Movement of Agency Workers

    Directory of Open Access Journals (Sweden)

    Chang-De Liu

    2016-07-01

    Full Text Available The number of agency workers in the PTS had increased rapidly since 2008, while a total of around 200 agency workers represented 20% of the PTS employees during recent years. However, most of agency works in the PTS were “long-term core jobs” rather than “temporary peripheral jobs,” and the recruitment, remuneration and benefits of agency workers were actually decided by the user enterprise, the PTS, rather than the employment agency. The agency employment in the PTS, therefore, had become the “in-house agency work” which broke the rules of related employment laws. According to the findings based on the questionnaire survey and in-depth interviews, the PTS agency workers were relatively young and high-educated, but most of them suffered from job insecurity and wage discrimination. Most interviewees were discontent with poor working conditions while highly evaluated and identified with the public interests that the PTS pursued. In 2013, the PTS agency employees established a union and urged the management for a transition to standard employment. Nevertheless, the standard employees and their union (the PTS union spoke out against the “total transition plan,” and forced the employer laid off 6 agency workers while a total of 130 agency workers were successfully transited. The union movement of the PTS agency workers is unique for its two characteristics, including the internalization of public interests among the PTS members, and the young generation’s disobedience to the capitalism under the crisis of pauperization of work.

  18. A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Yoon, Dong Jin; Kueon, Jae Hwa; Lee, Young Seop

    2004-01-01

    Patch type piezo-polymer sensors for smart structures were experimented to detect elastic wave. The pencil lead braking test was performed to analyze the characteristics of patch-type piezo-polymer sensors such as polyvinyliden fluoride (PVDF) and polyvinylidene fluoride trifluorethylene (P(VDF-TrFE)) for several test specimens with various elastic wave velocities and acoustical impedances. The characteristics of the patch-type piezo-polymer sensor were compared with the commercial PZT acoustic emission (AE) sensor. The vacuum grease and epoxy resin were used as a couplant for the acoustic impedance matching between the sensor and specimen. The peak amplitude of elastic wave increased as the diameter of piezo-film and acoustical impedance of the specimen increased. The frequency detection range of the piezo-film sensors decreased with increasing diameter of the piezo-film sensor. The P(VDF-TrFE) sensor was more sensitive than the PVDF sensor

  19. Piezo proteins: regulators of mechanosensation and other cellular processes.

    Science.gov (United States)

    Bagriantsev, Sviatoslav N; Gracheva, Elena O; Gallagher, Patrick G

    2014-11-14

    Piezo proteins have recently been identified as ion channels mediating mechanosensory transduction in mammalian cells. Characterization of these channels has yielded important insights into mechanisms of somatosensation, as well as other mechano-associated biologic processes such as sensing of shear stress, particularly in the vasculature, and regulation of urine flow and bladder distention. Other roles for Piezo proteins have emerged, some unexpected, including participation in cellular development, volume regulation, cellular migration, proliferation, and elongation. Mutations in human Piezo proteins have been associated with a variety of disorders including hereditary xerocytosis and several syndromes with muscular contracture as a prominent feature. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  20. Theoretical study of piezo-phototronic nano-LEDs.

    Science.gov (United States)

    Liu, Ying; Niu, Simiao; Yang, Qing; Klein, Benjamin D B; Zhou, Yu Sheng; Wang, Zhong Lin

    2014-11-12

    Two-dimensional finite-element simulation of the piezo-phototronic effect in p-n-junction-based devices is carried out for the first time. A charge channel can be induced at the p-n junction interface when strain is applied, given the n-side is a piezoelectric semiconductor and the p-type side is non-piezoelectric semiconductor. This provides the first simulated evidence supporting the previously suggested mechanism responsible for the experimentally observed gigantic change of light-emission efficiency in piezo-phototronic light-emitting devices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Characterization of a piezo bendable X-ray mirror.

    Science.gov (United States)

    Vannoni, Maurizio; Freijo Martín, Idoia; Siewert, Frank; Signorato, Riccardo; Yang, Fan; Sinn, Harald

    2016-01-01

    A full-scale piezo bendable mirror built as a prototype for an offset mirror at the European XFEL is characterized. The piezo ceramic elements are glued onto the mirror substrate, side-face on with respect to the reflecting surface. Using a nanometre optical component measuring machine and a large-aperture Fizeau interferometer, the mirror profile and influence functions were characterized, and further analysis was made to investigate the junction effect, hysteresis, twisting and reproducibility.

  2. A Comparison of Electrolytic Capacitors and Supercapacitors for Piezo-Based Energy Harvesting

    Science.gov (United States)

    2013-07-01

    A Comparison of Electrolytic Capacitors and Supercapacitors for Piezo-Based Energy Harvesting by Matthew H. Ervin, Carlos M. Pereira, John R...Capacitors and Supercapacitors for Piezo-Based Energy Harvesting Matthew H. Ervin Sensors and Electronic Devices Directorate, ARL Carlos M. Pereira... Supercapacitors for Piezo-Based Energy Harvesting 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Matthew H

  3. Features of the piezo-phototronic effect on optoelectronic devices based on wurtzite semiconductor nanowires.

    Science.gov (United States)

    Yang, Qing; Wu, Yuanpeng; Liu, Ying; Pan, Caofeng; Wang, Zhong Lin

    2014-02-21

    The piezo-phototronic effect, a three way coupling effect of piezoelectric, semiconductor and photonic properties in non-central symmetric semiconductor materials, utilizing the piezo-potential as a "gate" voltage to tune the charge transport/generation/recombination and modulate the performance of optoelectronic devices, has formed a new field and attracted lots of interest recently. The mechanism was verified in various optoelectronic devices such as light emitting diodes (LEDs), photodetectors and solar cells etc. The fast development and dramatic increasing interest in the piezo-phototronic field not only demonstrate the way the piezo-phototronic effects work, but also indicate the strong need for further research in the physical mechanism and potential applications. Furthermore, it is important to distinguish the contribution of the piezo-phototronic effect from other factors induced by external strain such as piezoresistance, band shifting or contact area change, which also affect the carrier behaviour and device performance. In this perspective, we review our recent progress on piezo-phototronics and especially focus on pointing out the features of piezo-phototronic effect in four aspects: I-V characteristics; c-axis orientation; influence of illumination; and modulation of carrier behaviour. Finally we proposed several criteria for describing the contribution made by the piezo-phototronic effect to the performance of optoelectronic devices. This systematic analysis and comparison will not only help give an in-depth understanding of the piezo-phototronic effect, but also work as guide for the design of devices in related areas.

  4. Mechanical sensitivity of Piezo1 ion channels can be tuned by cellular membrane tension

    Science.gov (United States)

    Lewis, Amanda H; Grandl, Jörg

    2015-01-01

    Piezo1 ion channels mediate the conversion of mechanical forces into electrical signals and are critical for responsiveness to touch in metazoans. The apparent mechanical sensitivity of Piezo1 varies substantially across cellular environments, stimulating methods and protocols, raising the fundamental questions of what precise physical stimulus activates the channel and how its stimulus sensitivity is regulated. Here, we measured Piezo1 currents evoked by membrane stretch in three patch configurations, while simultaneously visualizing and measuring membrane geometry. Building on this approach, we developed protocols to minimize resting membrane curvature and tension prior to probing Piezo1 activity. We find that Piezo1 responds to lateral membrane tension with exquisite sensitivity as compared to other mechanically activated channels and that resting tension can drive channel inactivation, thereby tuning overall mechanical sensitivity of Piezo1. Our results explain how Piezo1 can function efficiently and with adaptable sensitivity as a sensor of mechanical stimulation in diverse cellular contexts. DOI: http://dx.doi.org/10.7554/eLife.12088.001 PMID:26646186

  5. Piezo-Phototronic Effect in a Quantum Well Structure.

    Science.gov (United States)

    Huang, Xin; Du, Chunhua; Zhou, Yongli; Jiang, Chunyan; Pu, Xiong; Liu, Wei; Hu, Weiguo; Chen, Hong; Wang, Zhong Lin

    2016-05-24

    With enhancements in the performance of optoelectronic devices, the field of piezo-phototronics has attracted much attention, and several theoretical works have been reported based on semiclassical models. At present, the feature size of optoelectronic devices are rapidly shrinking toward several tens of nanometers, which results in the quantum confinement effect. Starting from the basic piezoelectricity equation, Schrödinger equation, Poisson equation, and Fermi's golden rule, a self-consistent theoretical model is proposed to study the piezo-phototronic effect in the framework of perturbation theory in quantum mechanics. The validity and universality of this model are well-proven with photoluminescence measurements in a single GaN/InGaN quantum well and multiple GaN/InGaN quantum wells. This study provides important insight into the working principle of nanoscale piezo-phototronic devices as well as guidance for the future device design.

  6. Obstructive Sleep Apnea Screening Using a Piezo-Electric Sensor.

    Science.gov (United States)

    Erdenebayar, Urtnasan; Park, Jong Uk; Jeong, Pilsoo; Lee, Kyoung Joung

    2017-06-01

    In this study, we propose a novel method for obstructive sleep apnea (OSA) detection using a piezo-electric sensor. OSA is a relatively common sleep disorder. However, more than 80% of OSA patients remain undiagnosed. We investigated the feasibility of OSA assessment using a single-channel physiological signal to simplify the OSA screening. We detected both snoring and heartbeat information by using a piezo-electric sensor, and snoring index (SI) and features based on pulse rate variability (PRV) analysis were extracted from the filtered piezo-electric sensor signal. A support vector machine (SVM) was used as a classifier to detect OSA events. The performance of the proposed method was evaluated on 45 patients from mild, moderate, and severe OSA groups. The method achieved a mean sensitivity, specificity, and accuracy of 72.5%, 74.2%, and 71.5%; 85.8%, 80.5%, and 80.0%; and 70.3%, 77.1%, and 71.9% for the mild, moderate, and severe groups, respectively. Finally, these results not only show the feasibility of OSA detection using a piezo-electric sensor, but also illustrate its usefulness for monitoring sleep and diagnosing OSA. © 2017 The Korean Academy of Medical Sciences.

  7. Merkel cells and Meissner's corpuscles in human digital skin display Piezo2 immunoreactivity.

    Science.gov (United States)

    García-Mesa, Y; García-Piqueras, J; García, B; Feito, J; Cabo, R; Cobo, J; Vega, J A; García-Suárez, O

    2017-12-01

    The transformation of mechanical energy into electrical signals is the first step in mechanotransduction in the peripheral sensory nervous system and relies on the presence of mechanically gated ion channels within specialized sensory organs called mechanoreceptors. Piezo2 is a vertebrate stretch-gated ion channel necessary for mechanosensitive channels in mammalian cells. Functionally, it is related to light touch, which has been detected in murine cutaneous Merkel cell-neurite complexes, Meissner-like corpuscles and lanceolate nerve endings. To the best of our knowledge, the occurrence of Piezo2 in human cutaneous mechanoreceptors has never been investigated. Here, we used simple and double immunohistochemistry to investigate the occurrence of Piezo2 in human digital glabrous skin. Piezo2 immunoreactivity was detected in approximately 80% of morphologically and immunohistochemically characterized (cytokeratin 20 + , chromogranin A + and synaptophisin + ) Merkel cells. Most of them were in close contact with Piezo2 - nerve fibre profiles. Moreover, the axon, but not the lamellar cells, of Meissner's corpuscles was also Piezo2 + , but other mechanoreceptors, i.e. Pacinian or Ruffini's corpuscles, were devoid of immunoreactivity. Piezo2 was also observed in non-nervous tissue, especially the basal keratinocytes, endothelial cells and sweat glands. The present results demonstrate the occurrence of Piezo2 in cutaneous sensory nerve formations that functionally work as slowly adapting (Merkel cells) and rapidly adapting (Meissner's corpuscles) low-threshold mechanoreceptors and are related to fine and discriminative touch but not to vibration or hard touch. These data offer additional insight into the molecular basis of mechanosensing in humans. © 2017 Anatomical Society.

  8. Ultrasonic guided wave sensing characteristics of large area thin piezo coating

    Science.gov (United States)

    Rathod, V. T.; Jeyaseelan, A. Antony; Dutta, Soma; Mahapatra, D. Roy

    2017-10-01

    This paper reports on the characterization method and performance enhancement of thin piezo coating for ultrasonic guided wave sensing applications. We deposited the coatings by an in situ slurry coating method and studied their guided wave sensing properties on a one-dimensional metallic beam as a substrate waveguide. The developed piezo coatings show good sensitivity to the longitudinal and flexural modes of guided waves. Sensing voltage due to the guided waves at various different ultrasonic frequencies shows a linear dependence on the thickness of the coating. The coatings also exhibit linear sensor output voltage with respect to the induced dynamic strain magnitude. Diameter/size of the piezo coatings strongly influences the voltage response in relation to the wavelength. The proposed method used a characterization set-up involving coated sensors, reference transducers and an analytical model to estimate the piezoelectric coefficient of the piezo coating. The method eliminates the size dependent effect on the piezo property accurately and gives further insight to design better sensors/filters with respect to frequency/wavelength of interest. The developed coatings will have interesting applications in structural health monitoring (SHM) and internet of things (IOT).

  9. Fabrication Effects on Polysilicon-based Micro cantilever Piezo resistivity for Biological Sensing Application

    International Nuclear Information System (INIS)

    Nina Korlina Madzhi; Balkish Natra; Mastura Sidek; Khuan, L.Y.; Anuar Ahmad

    2011-01-01

    In principle, adsorption of biological molecules on a functionalized surface of a micro fabricated cantilever will cause a surface stress and consequently the cantilever bending. In this work, four different type of polysilicon-based piezo resistive micro cantilever sensors were designed to increase the sensitivity of the micro cantilevers sensor because the forces involved is very small. The design and optimization was performed by using finite element analysis to maximize the relative resistance changes of the piezo resistors as a function of the cantilever vertical displacements. The resistivity of the piezo resistivity micro cantilevers was analyzed before and after dicing process. The maximum resistance changes were systematically investigated by varying the piezo resistor length. The results show that although the thickness of piezo resistor was the same at 0.5 μm the resistance value was varied. (author)

  10. Piezo Proteins: Regulators of Mechanosensation and Other Cellular Processes*

    OpenAIRE

    Bagriantsev, Sviatoslav N.; Gracheva, Elena O.; Gallagher, Patrick G.

    2014-01-01

    Piezo proteins have recently been identified as ion channels mediating mechanosensory transduction in mammalian cells. Characterization of these channels has yielded important insights into mechanisms of somatosensation, as well as other mechano-associated biologic processes such as sensing of shear stress, particularly in the vasculature, and regulation of urine flow and bladder distention. Other roles for Piezo proteins have emerged, some unexpected, including participation in cellular deve...

  11. A piezo-bar pressure probe

    Science.gov (United States)

    Friend, W. H.; Murphy, C. L.; Shanfield, I.

    1967-01-01

    Piezo-bar pressure type probe measures the impact velocity or pressure of a moving debris cloud. It measures pressures up to 200,000 psi and peak pressures may be recorded with a total pulse duration between 5 and 65 musec.

  12. Micro Coriolis mass flow sensor driven by external piezo ceramic

    NARCIS (Netherlands)

    Zeng, Yaxiang; Groenesteijn, Jarno; Alveringh, Dennis; Wiegerink, Remco J.; Lötters, Joost Conrad

    2017-01-01

    We have realized a micro Coriolis mass flow meter driven with an external piezo ceramic. The piezoelec tric ceramic is glued on top of sensor chip with a inertial weight on top of the piezo ceramic. Its ability to measure mass flow is characterized by a laser Doppler vibrometer. Our measurement with

  13. Pressure tracking control of vehicle ABS using piezo valve modulator

    Science.gov (United States)

    Jeon, Juncheol; Choi, Seung-Bok

    2011-03-01

    This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.

  14. GEC Ferranti piezo vibratory gyroscope

    Science.gov (United States)

    Nuttall, J. D.

    1993-01-01

    Prototypes of a piezo-electric vibratory angular rate transducer (gyroscope) (PVG) have been constructed and evaluated. The construction is on the lines suggested by Burdess. The sensitive element is a cylinder of radially poled piezo-electric ceramic. The cylinder is metallized inside and out, and the outer metallization is divided into eight electrodes. The metallization on the inside is earthed. A phase locked loop, using pairs of the electrodes, causes the cylinder to vibrate in one of its two fundamental, degenerate modes. In the presence of rotation, some of the vibration is coupled into the outer mode. This can be detected, or suppressed with a closed-up technique and provides a measure of rotation rate. The gyroscope provides a number of advantages over rotating mass and optical instruments: low size and mass, lower power consumption, potentially high reliability, potentially good dormancy, low cost and high maximum rate.

  15. Structural characterization of the PTS IIA and IIB proteins associated with pneumococcal fucose utilization.

    Science.gov (United States)

    Higgins, Melanie A; Hamilton, Aileen M; Boraston, Alisdair B

    2017-05-01

    Streptococcus pneumoniae harbors a significant number of transporters, including phosphotransferase (PTS) systems, allowing the bacterium to utilize a number of different carbohydrates for metabolic and other purposes. The genes encoding for one PTS transport system in particular (EII fuc ) are found within a fucose utilization operon in S. pneumoniae TIGR4. Here, we report the three-dimensional structures of IIA fuc and IIB fuc providing evidence that this PTS system belongs to the EII man family. Additionally, the predicted metabolic pathway for this distinctive fucose utilization system suggests that EII fuc transports the H-disaccharide blood group antigen, which would represent a novel PTS transporter specificity. Proteins 2017; 85:963-968. © 2016 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. The Kinetics and the Permeation Properties of Piezo Channels.

    Science.gov (United States)

    Gnanasambandam, R; Gottlieb, P A; Sachs, F

    2017-01-01

    Piezo channels are eukaryotic, cation-selective mechanosensitive channels (MSCs), which show rapid activation and voltage-dependent inactivation. The kinetics of these channels are largely consistent across multiple cell types and different stimulation paradigms with some minor variability. No accessory subunits that associate with Piezo channels have been reported. They are homotrimers and each ∼300kD monomer has an N-terminal propeller blade-like mechanosensing module, which can confer mechanosensing capabilities on ASIC-1 (the trimeric non-MSC, acid-sensing ion channel-1) and a C-terminal pore module, which influences conductance, selectivity, and channel inactivation. Repeated stimulation can cause domain fracture and diffusion of these channels leading to synchronous loss of inactivation. The reconstituted channels spontaneously open only in asymmetric bilayers but lack inactivation. Mutations that cause hereditary xerocytosis alter PIEZO1 kinetics. The kinetics of the wild-type PIEZO1 and alterations thereof in mutants (M2225R, R2456K, and DhPIEZO1) are summarized in the form of a quantitative model and hosted online. The pore is permeable to alkali ions although Li + permeates poorly. Divalent cations, notably Ca 2+ , traverse the channel and inhibit the flux of monovalents. The large monovalent organic cations such as tetramethyl ammonium and tetraethyl ammonium can traverse the channel, but slowly, suggesting a pore diameter of ∼8Å, and the estimated in-plane area change upon opening is around 6-20nm 2 . Ruthenium red can enter the channel only from the extracellular side and seems to bind in a pocket close to residue 2496. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Tuning Piezo ion channels to detect molecular-scale movements relevant for fine touch

    Science.gov (United States)

    Poole, Kate; Herget, Regina; Lapatsina, Liudmila; Ngo, Ha-Duong; Lewin, Gary R.

    2014-01-01

    In sensory neurons, mechanotransduction is sensitive, fast and requires mechanosensitive ion channels. Here we develop a new method to directly monitor mechanotransduction at defined regions of the cell-substrate interface. We show that molecular-scale (~13 nm) displacements are sufficient to gate mechanosensitive currents in mouse touch receptors. Using neurons from knockout mice, we show that displacement thresholds increase by one order of magnitude in the absence of stomatin-like protein 3 (STOML3). Piezo1 is the founding member of a class of mammalian stretch-activated ion channels, and we show that STOML3, but not other stomatin-domain proteins, brings the activation threshold for Piezo1 and Piezo2 currents down to ~10 nm. Structure–function experiments localize the Piezo modulatory activity of STOML3 to the stomatin domain, and higher-order scaffolds are a prerequisite for function. STOML3 is the first potent modulator of Piezo channels that tunes the sensitivity of mechanically gated channels to detect molecular-scale stimuli relevant for fine touch. PMID:24662763

  18. The annealing effects on irradiated SiC piezo resistive pressure sensor

    International Nuclear Information System (INIS)

    Almaz, E.; Blue, T. E.; Zhang, P.

    2009-01-01

    The effects of temperature on annealing of Silicon Carbide (SiC) piezo resistive pressure sensor which was broken after high fluence neutron irradiation, were investigated. Previously, SiC piezo resistive sensor irradiated with gamma ray and fast neutron in the Co-60 gamma-ray irradiator and Beam Port 1 (BP1) and Auxiliary Irradiation Facility (AIF) at the Ohio State University Nuclear Reactor Laboratory (OSUNRL) respectively. The Annealing temperatures were tested up to 400 C. The Pressure-Output voltage results showed recovery after annealing process on SiC piezo resistive pressure sensor. The bridge resistances of the SiC pressure sensor stayed at the same level up to 300 C. After 400 C annealing, the resistance values changed dramatically.

  19. Measurement of absolute displacement-amplitude of ultrasonic wave using piezo-electric detection method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Hyun; Kim, Jong Beom; Jhang, Kyung Young [Hanyang University, Seoul (Korea, Republic of)

    2017-02-15

    A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

  20. Measurement of absolute displacement-amplitude of ultrasonic wave using piezo-electric detection method

    International Nuclear Information System (INIS)

    Park, Seong Hyun; Kim, Jong Beom; Jhang, Kyung Young

    2017-01-01

    A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process

  1. PAPR Reduction of OFDM Signals by Novel Global Harmony Search in PTS Scheme

    Directory of Open Access Journals (Sweden)

    Hojjat Salehinejad

    2012-01-01

    Full Text Available The orthogonal frequency division multiplexing (OFDM modulation technique is one of the key strategies for multiuser signal transmission especially in smart grids and wind farms. This paper introduces an approach for peak-to-average power ratio (PAPR reduction of such signals based on novel global harmony search (NGHS and partial transmit sequence (PTS schemes. In PTS technique, the data block to be transmitted is partitioned into disjoint subblocks, which are combined using phase factors to minimize PAPR. The PTS requires an exhaustive search over all combinations of allowed phase factors. Therefore, with respect to the fast implementation and simplicity of NGHS technique, we could achieve significant reduction of PAPR.

  2. Ionic Selectivity and Permeation Properties of Human PIEZO1 Channels.

    Directory of Open Access Journals (Sweden)

    Radhakrishnan Gnanasambandam

    Full Text Available Members of the eukaryotic PIEZO family (the human orthologs are noted hPIEZO1 and hPIEZO2 form cation-selective mechanically-gated channels. We characterized the selectivity of human PIEZO1 (hPIEZO1 for alkali ions: K+, Na+, Cs+ and Li+; organic cations: TMA and TEA, and divalents: Ba2+, Ca2+, Mg2+ and Mn2+. All monovalent ions permeated the channel. At a membrane potential of -100 mV, Cs+, Na+ and K+ had chord conductances in the range of 35-55 pS with the exception of Li+, which had a significantly lower conductance of ~ 23 pS. The divalents decreased the single-channel permeability of K+, presumably because the divalents permeated slowly and occupied the open channel for a significant fraction of the time. In cell-attached mode, 90 mM extracellular divalents had a conductance for inward currents carried by the divalents of: 25 pS for Ba2+ and 15 pS for Ca2+ at -80 mV and 10 pS for Mg2+ at -50 mV. The organic cations, TMA and TEA, permeated slowly and attenuated K+ currents much like the divalents. As expected, the channel K+ conductance increased with K+ concentration saturating at ~ 45 pS and the KD of K+ for the channel was 32 mM. Pure divalent ion currents were of lower amplitude than those with alkali ions and the channel opening rate was lower in the presence of divalents than in the presence of monovalents. Exposing cells to the actin disrupting reagent cytochalasin D increased the frequency of openings in cell-attached patches probably by reducing mechanoprotection.

  3. Harvesting vibrational energy due to intermodal systems via nano coated piezo electric devices.

    Science.gov (United States)

    2015-12-01

    Vibrational energy resulting from intermodal transport systems can be recovered through the use of energy harvesting system consisting of PZT piezo electric material as the primary energy harvesting component. The ability of traditional PZT piezo ele...

  4. Russian practice of RPV integrity assessment under PTS conditions

    International Nuclear Information System (INIS)

    Piminov, V.; Dragunov, Yu.; Kostyrkin, S.; Akbachev, I.

    1997-01-01

    In this paper the approach used by Gidopress (main designer of Russian WWER reactors) for RPV integrity assessment is presented. Recently performed calculations for RPVs of Novoronezh NPP, units 3 and 4, are used as an example of practical application of this approach. The calculations have been performed on the base of Russian regulatory requirements, at the same time the recommendations of IAEA Guidelines for PTS assessment was also taken into account. The scope of the work includes: Analysis of real state of NPP systems and PTS selection; analysis of material behavior including results of templets investigation; thermal hydraulic calculations; structural analyses for the leading transients; development of supplementary measures to reduce the risk of RPV fracture. 5 refs, 9 figs, 1 tab

  5. Russian practice of RPV integrity assessment under PTS conditions

    Energy Technology Data Exchange (ETDEWEB)

    Piminov, V; Dragunov, Yu; Kostyrkin, S; Akbachev, I

    1997-09-01

    In this paper the approach used by Gidopress (main designer of Russian WWER reactors) for RPV integrity assessment is presented. Recently performed calculations for RPVs of Novoronezh NPP, units 3 and 4, are used as an example of practical application of this approach. The calculations have been performed on the base of Russian regulatory requirements, at the same time the recommendations of IAEA Guidelines for PTS assessment was also taken into account. The scope of the work includes: Analysis of real state of NPP systems and PTS selection; analysis of material behavior including results of templets investigation; thermal hydraulic calculations; structural analyses for the leading transients; development of supplementary measures to reduce the risk of RPV fracture. 5 refs, 9 figs, 1 tab.

  6. Implementasi dan Analisis Teknik Reduksi PAPR OFDM Menggunakan Metode PTS pada WARP

    Directory of Open Access Journals (Sweden)

    Rizkha Ajeng Rochmatika

    2017-01-01

    Full Text Available Sistem OFDM cocok digunakan sebagai solusi yang dapat memenuhi layanan komunikasi data kecepatan tinggi karena memiliki efisiensi bandwidth dengan performansi terbaik. Namun dalam implementasinya, sistem OFDM memiliki kelemahan yang disebabkan oleh tingginya nilai Peak to Average Power Ratio (PAPR sehingga sinyal OFDM rentan terkena distorsi nonlinear yang disebabkan oleh adanya komponen RF power amplifier yang menyebabkan kompleksitas komponen Analog to Digital Converter (ADC yang terdapat pada Wireless Open Access Research Platform (WARP. Nilai PAPR yang besar pada OFDM membutuhkan power amplifier dengan dynamic range yang lebar untuk mengakomodasi sinyal, apabila hal tersebut tidak terpenuhi maka menyebabkan distorsi nonlinear dan pada akhirnya menurunkan performansi OFDM. Oleh karena itu, untuk mengatasinya dibutuhkan suatu metode yang dapat mereduksi nilai PAPR salah satunya menggunakan metode PTS. Guna melihat unjuk kerja teknik PTS, maka pada penelitian ini dibandingkan dua skema antara sistem OFDM tanpa dan dengan teknik PTS menggunakan analisa pada bit error rate dan nilai CCDF. Dari hasil pengukuran menunjukkan bahwa implementasi kinerja teknik PTS mampu meningkatkan kinerja sistem OFDM saat terkena distorsi nonlinear, terlihat pada pengukuran dengan modulasi 16-QAM untuk gain 56 didapatkan peningkatan BER sebesar 95.98%. Sedangkan pada grafik CCDF terjadi penurunan nilai PAPR sebesar 34.17% untuk M=4.

  7. A Flexure-Guided Piezo Drill for Penetrating the Zona Pellucida of Mammalian Oocytes.

    Science.gov (United States)

    Johnson, Wesley; Dai, Changsheng; Liu, Jun; Wang, Xian; Luu, Devin K; Zhang, Zhuoran; Ru, Changhai; Zhou, Chao; Tan, Min; Pu, Huayan; Xie, Shaorong; Peng, Yan; Luo, Jun; Sun, Yu

    2018-03-01

    Mammalian oocytes such as mouse oocytes have a highly elastic outer membrane, zona pellucida (ZP) that cannot be penetrated without significantly deforming the oocyte, even with a sharp micropipette. Piezo drill devices leverage lateral and axial vibration of the micropipette to accomplish ZP penetration with greatly reduced oocyte deformation. However, existing piezo drills all rely on a large lateral micropipette vibration amplitude ( 20 ) and a small axial vibration amplitude (0.1 ). The very large lateral vibration amplitude has been deemed to be necessary for ZP penetration although it also induces larger oocyte deformation and more oocyte damage. This paper reports on a new piezo drill device that uses a flexure guidance mechanism and a systematically designed pulse train with an appropriate base frequency. Both simulation and experimental results demonstrate that a small lateral vibration amplitude (e.g., 2 ) and an axial vibration amplitude as large as 1.2 were achieved. Besides achieving 100% effectiveness in the penetration of mouse oocytes (n = 45), the new piezo device during ZP penetration induced a small oocyte deformation of 3.4 versus larger than 10 using existing piezo drill devices.

  8. RELAP5 analyses and support of Oconee-1 PTS studies

    International Nuclear Information System (INIS)

    Charlton, T.R.

    1983-01-01

    The integrity of a reactor vessel during a severe overcooling transient with primary system pressurization is a current safety concern and has been identified as an Unresolved Safety Issue(USI) A-49 by the US Nuclear Regulatory Commission (NRC). Resolution of USI A-49, denoted as Pressurized Thermal Shock (PTS), is being examined by the US NRC sponsored PTS integration study. In support of this study, the Idaho National Engineering Laboratory (INEL) has performed RELAP5/MOD1.5 thermal-hydraulic analyses of selected overcooling transients. These transient analyses were performed for the Oconee-1 pressurized water reactor (PWR), which is Babcock and Wilcox designed nuclear steam supply system

  9. Predictive value of markers of inflammation in the postthrombotic syndrome: a systematic review: inflammatory biomarkers and PTS.

    Science.gov (United States)

    Rabinovich, A; Cohen, J M; Kahn, S R

    2015-08-01

    The postthrombotic syndrome (PTS) is a chronic complication of deep vein thrombosis (DVT). Inflammation may contribute to its pathophysiology. We conducted a systematic review of studies that analyzed the association between biomarkers of inflammation and PTS in DVT patients. The electronic databases PubMed, EMBASE, Medline, Scopus and Web of Science were searched for studies published until March 2015 that measured blood inflammation biomarker levels in adult DVT patients and reported their association with PTS development. Two reviewers independently performed full text assessment and data extraction. Ten studies were included. Nine reported on the association between C-reactive protein and PTS; Interleukin (IL)-6 was measured in six studies; IL-8 in four studies; Intracellular adhesion molecule (ICAM)-1 in three studies; IL-10 and vascular cell adhesion molecule-1 in two studies; and monocyte chemotactic protein-1, matrix metalloprotease-9, P-Selectin, tumor necrosis factor α and erythrocyte sedimentation rate were measured in one study. Studies differed in terms of populations included, exclusion criteria, methods used for biomarker measurement and statistical measures of association between biomarkers and PTS. We were able to metaanalyze results only for IL-6 and found no significant association. Descriptively, ICAM-1 was significantly associated with PTS in two out of three studies that measured it. Other biomarkers did not demonstrate a significant association with PTS. Our systematic review found conflicting results regarding the role of inflammatory biomarkers as predictors of PTS. ICAM -1 appears to be a promising marker for further investigation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. High-power piezo drive amplifier for large stack and PFC applications

    Science.gov (United States)

    Clingman, Dan J.; Gamble, Mike

    2001-08-01

    This paper describes the continuing development of Boeing High Power Piezo Drive Amplifiers. Described is the development and testing of a 1500 Vpp, 8 amp switching amplifier. This amplifier is used to drive a piezo stack driven rotor blade trailing edge flap on a full size helicopter. Also discuss is a switching amplifier designed to drive a Piezo Fiber Composite (PFC) active twist rotor blade. This amplifier was designed to drive the PFC material at 2000 Vpp and 0.5 amps. These amplifiers recycle reactive energy, allowing for a power and weight efficient amplifier design. This work was done in conjunction with the DARPA sponsored Phase II Smart Rotor Blade program and the NASA Langley Research Center sponsored Active Twist Rotor (ATR) blade program.

  11. Fundamental piezo-Hall coefficients of single crystal p-type 3C-SiC for arbitrary crystallographic orientation

    Science.gov (United States)

    Qamar, Afzaal; Dao, Dzung Viet; Phan, Hoang-Phuong; Dinh, Toan; Dimitrijev, Sima

    2016-08-01

    Piezo-Hall effect in a single crystal p-type 3C-SiC, grown by LPCVD process, has been characterized for various crystallographic orientations. The quantified values of the piezo-Hall effect in heavily doped p-type 3C-SiC(100) and 3C-SiC(111) for different crystallographic orientations were used to obtain the fundamental piezo-Hall coefficients, P 12 = ( 5.3 ± 0.4 ) × 10 - 11 Pa - 1 , P 11 = ( - 2.6 ± 0.6 ) × 10 - 11 Pa - 1 , and P 44 = ( 11.42 ± 0.6 ) × 10 - 11 Pa - 1 . Unlike the piezoresistive effect, the piezo-Hall effect for (100) and (111) planes is found to be independent of the angle of rotation of the device within the crystal plane. The values of fundamental piezo-Hall coefficients obtained in this study can be used to predict the piezo-Hall coefficients in any crystal orientation which is very important for designing of 3C-SiC Hall sensors to minimize the piezo-Hall effect for stable magnetic field sensitivity.

  12. Sensitivity enhancement of polysilicon piezo-resistive pressure sensors with phosphorous diffused resistors

    International Nuclear Information System (INIS)

    Sivakumar, K; Dasgupta, N; Bhat, K N; Natarajan, K

    2006-01-01

    It is generally accepted that the piezo-resistive coefficient in single crystal silicon is higher when P-type impurities such as boron are used for doping the resistors. In this paper we demonstrate that the sensitivity of polycrystalline silicon piezo-resistive pressure sensors can be enhanced considerably when phosphorus diffusion source is used instead of boron dopant for realizing the piezo-resistors. Pressure sensors have been designed and fabricated with the polycrystalline piezo-resistors connected in the form of a Wheatstone bridge and laid out on thermal oxide grown on membranes obtained with a Silicon On Insulator (SOI) approach. The SOI wafers required for this purpose have been realized in-house by Silicon Fusion Bonding (SFB) and etch back technique in our laboratory. This approach provides excellent isolation between the resistors and enables zero temperature coefficient of the polysilicon resistor. The results obtained in our laboratory have clearly demonstrated that by optimizing the phosphorus diffusion temperature and duration, it is possible to achieve sensitivities in excess of 20mV /Bar for bridge input voltage of 10V, with linearity within 1% over a differential pressure range up to 10Bar (10 6 Pascal), and burst pressure in excess of 50 Bar as compared to the 10mV /Bar sensitivity obtained with boron doped polysilicon piezo-resistors. This enhancement is attributed to grain boundary passivation by phosphorous atoms

  13. Three-dimensional model of a liquid-cooled, low energy booster, radio-frequency cavity tuner at the superconducting super collider

    International Nuclear Information System (INIS)

    Ranganathan, R.; Propp, A.; Campbell, B.; Dao, B.

    1994-01-01

    A three-dimensional computational heat transfer and fluid flow model was developed to analyze a forced-flow, liquid-cooled, low energy booster (LEB), radio-frequency (RF) cavity, tuner concept. The results for a commercial dielectric heat transfer fluid indicated safe temperatures in the ferrite

  14. Three-dimensional model of a liquid-cooled, low energy booster radio- frequency cavity tuner at the Superconducting Super Collider

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, R.; Propp, A.; Campbell, B.; Dao, B.

    1993-04-01

    A three-dimensional computational heat transfer and fluid flow model was developed to analyze a forced-flow, liquid-cooled, low energy booster (LEB) radio-frequency (RF) cavity tuner concept. The results for a commercial dielectric heat transfer fluid indicated safe temperatures in the ferrite.

  15. Three-dimensional model of a liquid-cooled, low energy booster radio- frequency cavity tuner at the Superconducting Super Collider

    International Nuclear Information System (INIS)

    Ranganathan, R.; Propp, A.; Campbell, B.; Dao, B.

    1993-04-01

    A three-dimensional computational heat transfer and fluid flow model was developed to analyze a forced-flow, liquid-cooled, low energy booster (LEB) radio-frequency (RF) cavity tuner concept. The results for a commercial dielectric heat transfer fluid indicated safe temperatures in the ferrite

  16. A piezo-film-based measurement system for global haemodynamic assessment

    International Nuclear Information System (INIS)

    Clemente, Fabrizio; Cimmino, Pasquale; Arpaia, Pasquale

    2010-01-01

    A non-invasive piezo-film-based measurement method for haemodynamic assessment is proposed. The design of a system, able to reconstruct the blood pressure waveform online by dealing with problems arising from the piezo-film capacitive nature in the targeted frequency range (from quasi-dc up to 12 Hz), is illustrated. The system is based on a commercial piezo-film placed easily on the radial artery with a special brace without any discomfort for the patient. The analogical conditioning circuit and digital signal processing are continuously tuned with the signal from the sensor to reconstruct the blood pressure signal online. Diagnostic schema, based on physio-pathological models, have been implemented in order to compute online trends of max[dP(t)/d(t)] and volemic status highly useful for the intensivist and anaesthesiologist. The system was characterized by numerical simulation and experimental in vivo comparison to the traditional reference system

  17. Quality assurance of PTS thermal hydraulic calculations at BNL

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Pu, J.; Jo, J.; Saha, P.

    1983-01-01

    Rapid cooling of the reactor pressure vessel at high pressure has a potential of challenging the vessel integrity. This phenomenon is called overcooling or Pressurized Thermal Shock (PTS). The Nuclear Regulatory Commission (NRC) has selected three plants representing three types of PWRs in use for detailed PTS study. Oconee-1 (B and W), Calvert Cliffs (C.E.), and H.B. Robinson (Westinghouse). The Brookhaven National Laboratory (BNL) has been requested by NRC to review and compare the input decks developed at LANL and INEL, and to compare and explain the differences between the common calculations performed at these two laboratories. However, for the transients that will be computed by only one laboratory, a consistency check will be performed. So far only Oconee-1 calculations have been reviewed at BNL, and the results are presented here

  18. Activation of TRPV1 channels inhibits mechanosensitive Piezo channel activity by depleting membrane phosphoinositides

    Science.gov (United States)

    Borbiro, Istvan; Badheka, Doreen; Rohacs, Tibor

    2015-01-01

    Capsaicin is an activator of the heat-sensitive TRPV1 (transient receptor potential vanilloid 1) ion channels and has been used as a local analgesic. We found that activation of TRPV1 channels with capsaicin either in dorsal root ganglion neurons or in a heterologous expression system inhibited the mechanosensitive Piezo1 and Piezo2 channels by depleting phosphatidylinositol 4,5-bisphosphate [PI(4,5)P2] and its precursor PI(4)P from the plasma membrane through Ca2+-induced phospholipase Cδ (PLCδ) activation. Experiments with chemically inducible phosphoinositide phosphatases and receptor-induced activation of PLCβ indicated that inhibition of Piezo channels required depletion of both PI(4)P and PI(4,5)P2. The mechanically activated current amplitudes decreased substantially in the excised inside-out configuration, where the membrane patch containing Piezo1 channels is removed from the cell. PI(4,5)P2 and PI(4)P applied to these excised patches inhibited this decrease. Thus, we concluded that Piezo channel activity requires the presence of phosphoinositides, and the combined depletion of PI(4,5)P2 or PI(4)P reduces channel activity. In addition to revealing a role for distinct membrane lipids in mechanosensitive ion channel regulation, these data suggest that inhibition of Piezo2 channels may contribute to the analgesic effect of capsaicin. PMID:25670203

  19. Verification of WPS effect under a PTS event

    International Nuclear Information System (INIS)

    Okamura, Hiroyuki; Yagawa, Genki; Urabe, Yoshio; Satoh, Masanobu; Tomimatsu, Minoru; Iida, Masato

    1993-01-01

    In WPS A1 test, K, was monotonically increased with thermal shock and constant tensile load by control of bending load. The specimen broke within the scatter band of K IC data. In WPS A2 test, initial specimen temperature was kept same as that of WPS A1 test and another PTS load was applied. No crack initiation took place when K I was within the scatter band of K IC at the decreasing stage. After that, bending load was increased up to brittle fracture at the temperature where WPS A1 test specimen broke. K I value at fracture for WPS A2 test specimen was beyond the upper bound of K IC data. That is, WPS effect was confirmed even for the low toughness steel like RPV wall under irradiation. Also K I value at fracture can be predicted by Chell's theory. By introducing WPS effect into PTS integrity analysis, much more temperature margin can be expected

  20. Progress in Piezo-Phototronic-Effect-Enhanced Light-Emitting Diodes and Pressure Imaging.

    Science.gov (United States)

    Pan, Caofeng; Chen, Mengxiao; Yu, Ruomeng; Yang, Qing; Hu, Youfan; Zhang, Yan; Wang, Zhong Lin

    2016-02-24

    Wurtzite materials exhibit both semiconductor and piezoelectric properties under strains due to the non-central symmetric crystal structures. The three-way coupling of semiconductor properties, piezoelectric polarization and optical excitation in ZnO, GaN, CdS and other piezoelectric semiconductors leads to the emerging field of piezo-phototronics. This effect can efficiently manipulate the emission intensity of light-emitting diodes (LEDs) by utilizing the piezo-polarization charges created at the junction upon straining to modulate the energy band diagrams and the optoelectronic processes, such as generation, separation, recombination and/or transport of charge carriers. Starting from fundamental physics principles, recent progress in piezo-phototronic-effect-enhanced LEDs is reviewed; following their development from single-nanowire pressure-sensitive devices to high-resolution array matrices for pressure-distribution mapping applications. The piezo-phototronic effect provides a promising method to enhance the light emission of LEDs based on piezoelectric semiconductors through applying static strains, and may find perspective applications in various optoelectronic devices and integrated systems. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. The amplitude modulation of laser diode emission with antireflection piezo films on mirrors

    International Nuclear Information System (INIS)

    Abrarov, S.M.; Karimov, Kh.S.; Akhmedov, Kh.M.

    2001-01-01

    Present article is devoted to amplitude modulation of laser diode emission with antireflection piezo films on mirrors. The modulator based on laser diode and the emission amplitude modulation of which is performed by electric field impact on antireflection piezo films applied on mirrors was studied.

  2. Service framework for Internet of People, Things and Services (IoPTS)

    DEFF Research Database (Denmark)

    Shinde, Gitanjali; Olesen, Henning

    2016-01-01

    Internet of Things (IoT) is a revolutionary technology, where devices around us will be capable of sensing, reacting, responding and working autonomously to provide services to the users e.g. within smart homes, enterprises, utilities and e-Health. In the IoT paradigm, every device...... will be connected to the Internet to provide services to the user. Bringing this together makes it relevant to talk about the "Internet of People, Things and Services (IoPTS)". However, providing the appropriate services to the users depending on their requirements is a major challenge for IoPTS. After reviewing...

  3. Bubbles in piezo-acoustic inkjet printing

    NARCIS (Netherlands)

    Lohse, D.; Jeurissen, R.J.M.; de Jong, J.; Versluis, M.; Wijshoff, H.M.A.; van den Berg, M.; Reinten, H.

    2008-01-01

    Ink-jet printing is considered as the hitherto most successful application of microfluidics. A notorious problem in piezo-acoustic ink-jet systems is the formation of air bubbles during operation. They seriously disturb the acoustics and can cause the droplet formation to stop. We could show by a

  4. Strongly bound excitons in monolayer PtS2 and PtSe2

    KAUST Repository

    Sajjad, M.

    2018-01-22

    Based on first-principles calculations, the structural, electronic, and optical properties of monolayers PtS2 and PtSe2 are investigated. The bond stiffnesses and elastic moduli are determined by means of the spring constants and strain-energy relations, respectively. Dynamic stability is confirmed by calculating the phonon spectra, which shows excellent agreement with experimental reports for the frequencies of the Raman-active modes. The Heyd-Scuseria-Ernzerhof functional results in electronic bandgaps of 2.66 eV for monolayer PtS2 and 1.74 eV for monolayer PtSe2. G0W0 calculations combined with the Bethe-Salpeter equation are used to predict the optical spectra and exciton binding energies (0.78 eV for monolayer PtS2 and 0.60 eV for monolayer PtSe2). It turns out that the excitons are strongly bound and therefore very stable against external perturbations.

  5. Enhanced Luminescence Performance of Quantum Wells by Coupling Piezo-Phototronic with Plasmonic Effects.

    Science.gov (United States)

    Huang, Xin; Jiang, Chunyan; Du, Chunhua; Jing, Liang; Liu, Mengmeng; Hu, Weiguo; Wang, Zhong Lin

    2016-12-27

    With a promising prospect of light-emitting diodes as an attractive alternative to conventional light sources, remaining challenges still cannot be addressed owing to their limited efficiency. Among the continued scientific efforts, significant improvement on the emission efficiency has been achieved via either piezo-phototronic effect-based strain modulation or resonant excitation of plasmons in metallic nanostructures. Here, we present the investigation on the coupling process between piezo-phototronic effect and localized surface plasmonic resonance for enhancing the photoluminescence of InGaN/GaN quantum wells coated with Ag nanoparticles. The underlying physical mechanism of experimental results originates from tuning plasmonic resonance controlled by the shift of emission wavelength via piezo-phototronic effect, and it is further confirmed with the support of theoretical calculations. As a result, our research provides an approach to the integration of plasmonics with piezo-phototronic effect and brings widespread applications to high-efficiency artificial lighting, on-chip integrated plasmonic circuits, subwavelength optical communication, and micro-optoelectronic mechanical systems.

  6. Method and Apparatus for High-Permeability Magnetostrictive/Piezo-Fiber Laminates Having Colossal, Near-Ideal Magnetoelectricity

    OpenAIRE

    2007-01-01

    An ME composite laminate of at least one (1-3) piezo-fiber layer coupled with high-permeability alloy magnetostrictive layers, optionally formed of FeBSiC or equivalent. The composite laminate alternates the (1-3) piezo-fiber and high-permeability alloy magnetostrictive layers in a stacked manner. Optionally, the magnetization direction of the high-permeability alloy magnetostrictive layers and polarization direction of the piezo-fiber layer are an (L-L) arrangement. Optionally, thin film pol...

  7. Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force.

    Science.gov (United States)

    Guo, Ying; Hou, Yubin; Lu, Qingyou

    2014-05-01

    We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.

  8. Confinement Sensing and Signal Optimization via Piezo1/PKA and Myosin II Pathways

    Directory of Open Access Journals (Sweden)

    Wei-Chien Hung

    2016-05-01

    Full Text Available Summary: Cells adopt distinct signaling pathways to optimize cell locomotion in different physical microenvironments. However, the underlying mechanism that enables cells to sense and respond to physical confinement is unknown. Using microfabricated devices and substrate-printing methods along with FRET-based biosensors, we report that, as cells transition from unconfined to confined spaces, intracellular Ca2+ level is increased, leading to phosphodiesterase 1 (PDE1-dependent suppression of PKA activity. This Ca2+ elevation requires Piezo1, a stretch-activated cation channel. Moreover, differential regulation of PKA and cell stiffness in unconfined versus confined cells is abrogated by dual, but not individual, inhibition of Piezo1 and myosin II, indicating that these proteins can independently mediate confinement sensing. Signals activated by Piezo1 and myosin II in response to confinement both feed into a signaling circuit that optimizes cell motility. This study provides a mechanism by which confinement-induced signaling enables cells to sense and adapt to different physical microenvironments. : Hung et al. demonstrate that a Piezo1-dependent intracellular calcium increase negatively regulates protein kinase A (PKA as cells transit from unconfined to confined spaces. The Piezo1/PKA and myosin II signaling modules constitute two confinement-sensing mechanisms. This study provides a paradigm by which signaling enables cells to sense and adapt to different microenvironments.

  9. Tunable biasing magnetic field design of ferrite tuner for ICRF heating system in EAST

    Science.gov (United States)

    Manman, XU; Yuntao, SONG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Guang, LIU; Zhen, PENG

    2017-11-01

    Ion cyclotron range of frequency (ICRF) heating has been used in tokamaks as one of the most successful auxiliary heating tools and has been adopted in the EAST. However, the antenna load will fluctuate with the change of plasma parameters in the ICRF heating process. To ensure the steady operation of the ICRF heating system in the EAST, fast ferrite tuner (FFT) has been carried out to achieve real-time impedance matching. For the requirements of the FFT impedance matching system, the magnet system of the ferrite tuner (FT) was designed by numerical simulations and experimental analysis, where the biasing magnetic circuit and alternating magnetic circuit were the key researched parts of the ferrite magnet. The integral design goal of the FT magnetic circuit is that DC bias magnetic field is 2000 Gs and alternating magnetic field is ±400 Gs. In the FTT, E-type magnetic circuit was adopted. Ferrite material is NdFeB with a thickness of 30 mm by setting the working point of NdFeB, and the ampere turn of excitation coil is 25 through the theoretical calculation and simulation analysis. The coil inductance to generate alternating magnetic field is about 7 mH. Eddy-current effect has been analyzed, while the magnetic field distribution has been measured by a Hall probe in the medium plane of the biasing magnet. Finally, the test results show the good performance of the biasing magnet satisfying the design and operating requirements of the FFT.

  10. Thermal mixing characteritics during a postulated PTS event

    International Nuclear Information System (INIS)

    Jung, Jae Won; Bang, Young Seok; Seul, Kwang Won; Kim, Hho Jung

    1998-01-01

    The present study aims to investigate the characteristics of thermal fluid mixing during a postulated loss of coolant accident (LOCA) under two-phase flow condition using RELAP5 code. The RELAP5 code has been widely used in estimating global system thermal-hydraulic behaviors. However, the RELAP5 is not fully verified for the prediction of thermal mixing phenomena due to its limitation to the multi-dimensional behavior. Therefore, supplementary analysis is required, which can address the performance and limitation of the current RELAP5 code in predicting the thermal mixing. Another objective of this study is to compare the applicable empirical correlation (Theofanous') and the calculation of simple mixing code (REMIX) with one predicted by RELAP5. By those comparisons the capability on PTS thermal mixing of the current RELAP5 can be evaluated. In this study, thermal mixing behavior is analyzed for the task of the international comparative assessment study on PTS (PTS-ICAS) which was proposed by OECD-NEA. Through some preliminary calculations using RELAP5, the boundary conditions relevant to the problem constraints are appropriately specified with some artificial assumptions. As a calculation results, system pressure, downcomer water level, wall heat transfer coefficient, etc., are predicted as suitable for given problem constraints. From the predicted thermal hydraulic behavior, it is shown that the thermal stratification begins to start around 200 seconds after high pressure safety injection. At 400 seconds, the maximum difference in azimuthal temperature distribution at the downcomer due to thermal mixing is predicted about 150 K. Based on the comparison of the current RELAP5 prediction with the Theofanous' correlation and the REMIX calculation, it is found that thermal stratification characteristics predicted by RELAP5 is agreed in qualitative manner to the empirical correlation

  11. In Touch With the Mechanosensitive Piezo Channels: Structure, Ion Permeation, and Mechanotransduction.

    Science.gov (United States)

    Geng, J; Zhao, Q; Zhang, T; Xiao, B

    2017-01-01

    Mechanotransduction, the conversion of mechanical forces into biological signals, plays critical roles in various physiological and pathophysiological processes in mammals, such as conscious sensing of touch, pain, and sound, as well as unconscious sensing of blood flow-associated shear stress, urine flow, and bladder distention. Among the various molecules involved in mechanotransduction, mechanosensitive (MS) cation channels have long been postulated to represent one critical class of mechanotransducers that directly and rapidly converts mechanical force into electrochemical signals. Despite the awareness of their functional significance, the molecular identities of MS cation channels in mammals had remained elusive for decades till the groundbreaking finding that the Piezo family of genes, including Piezo1 and Piezo2, constitutes their essential components. Since their identification about 6years ago, tremendous progress has been made in understanding their physiological and pathophysiological importance in mechanotransduction and their structure-function relationships of being the prototypic class of mammalian MS cation channels. On the one hand, Piezo proteins have been demonstrated to serve as physiologically and pathophysiologically important mechanotransducers for most, if not all, mechanotransduction processes. On the other hand, they have been shown to form a remarkable three-bladed, propeller-shaped homotrimeric channel complex comprising a separable ion-conducting pore module and mechanotransduction modules. In this chapter, we review the major advancements, with a particular focus on the structural and biophysical features that enable Piezo proteins to serve as sophisticated MS cation channels for force sensing, transduction, and ion conduction. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Origin of the Force: The Force-From-Lipids Principle Applied to Piezo Channels.

    Science.gov (United States)

    Cox, C D; Bavi, N; Martinac, B

    2017-01-01

    Piezo channels are a ubiquitously expressed, principal type of molecular force sensor in eukaryotes. They enable cells to decode a myriad of physical stimuli and are essential components of numerous mechanosensory processes. Central to their physiological role is the ability to change conformation in response to mechanical force. Here we discuss the evolutionary origin of Piezo in relation to other MS channels in addition to the force that gates Piezo channels. In particular, we discuss whether Piezo channels are inherently mechanosensitive in accordance with the force-from-lipid paradigm which has been firmly established for bacterial MS channels and two-pore domain K + (K 2P ) channels. We also discuss the evidence supporting a reliance on or direct interaction with structural scaffold proteins of the cytoskeleton and extracellular matrix according to the force-from-filament principle. In doing so, we explain the false dichotomy that these distinctions represent. We also discuss the possible unifying models that shed light on channel mechanosensitivity at the molecular level. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Air entrapment in piezo-driven inkjet printheads

    NARCIS (Netherlands)

    de Jong, J.; de Bruin, G.J.; de Bruin, Gerrit; Reinten, Hans; van den Berg, Marc; Wijshoff, Herman; Wijshoff, H.; Versluis, Michel; Lohse, Detlef

    2006-01-01

    The stability of inkjet printers is a major requirement for high-quality-printing. However, in piezo-driven inkjet printheads, air entrapment can lead to malfunctioning of the jet formation. The piezoactuator is employed to actively monitor the channel acoustics and to identify distortions at an

  14. The structure of a conserved Piezo channel domain reveals a novel beta sandwich fold

    Science.gov (United States)

    Kamajaya, Aron; Kaiser, Jens; Lee, Jonas; Reid, Michelle; Rees, Douglas C.

    2014-01-01

    Summary Piezo has recently been identified as a family of eukaryotic mechanosensitive channels composed of subunits containing over 2000 amino acids, without recognizable sequence similarity to other channels. Here, we present the crystal structure of a large, conserved extramembrane domain located just before the last predicted transmembrane helix of C. elegans PIEZO, which adopts a novel beta sandwich fold. The structure was also determined of a point mutation located on a conserved surface at the position equivalent to the human PIEZO1 mutation found in Dehydrated Hereditary Stomatocytosis (DHS) patients (M2225R). While the point mutation does not change the overall domain structure, it does alter the surface electrostatic potential that may perturb interactions with a yet-to-be identified ligand or protein. The lack of structural similarity between this domain and any previously characterized fold, including those of eukaryotic and bacterial channels, highlights the distinctive nature of the Piezo family of eukaryotic mechanosensitive channels. PMID:25242456

  15. PIEZO channel protein naturally expressed in human breast cancer cell MDA-MB-231 as probed by atomic force microscopy

    Science.gov (United States)

    Weng, Yuanqi; Yan, Fei; Chen, Runkang; Qian, Ming; Ou, Yun; Xie, Shuhong; Zheng, Hairong; Li, Jiangyu

    2018-05-01

    Mechanical stimuli drives many physiological processes through mechanically activated channels, and the recent discovery of PIEZO channel has generated great interests in its mechanotransduction. Many previous researches investigated PIEZO proteins by transcribing them in cells that originally have no response to mechanical stimulation, or by forming PIEZO-combined complexes in vitro, and few studied PIEZO protein's natural characteristics in cells. In this study we show that MDA-MB-231, a malignant cell in human breast cancer cell line, expresses the mechanosensitive behavior of PIEZO in nature without extra treatment, and we report its characteristics in response to localized mechanical stimulation under an atomic force microscope, wherein a correlation between the force magnitude applied and the channel opening probability is observed. The results on PIEZO of MDA-MB-231 can help establish a basis of preventing and controlling of human breast cancer cell via mechanical forces.

  16. Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ying; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-05-15

    We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increase output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.

  17. Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force

    International Nuclear Information System (INIS)

    Guo, Ying; Lu, Qingyou; Hou, Yubin

    2014-01-01

    We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increase output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope

  18. The piezo-magnetic parameters of Terfenol-D: An experimental viewpoint

    International Nuclear Information System (INIS)

    Davino, D.; Giustiniani, A.; Visone, C.

    2012-01-01

    Magnetostrictive and all multifunctional materials have experienced in the last decades a growing technological interest. Several contributions, in the literature, propose the above-mentioned materials in innovative sensors and actuators both for bulk and MEMS devices. More recently, magnetostrictive materials have been proposed for energy harvesting applications by exploiting the so-called Villari effect. In this case, the behavior and the amplitude of the piezo-magnetic coefficients are an important element to evaluate the conversion efficiency. Aim of this paper is to study the experimental behavior of the piezo-magnetic coefficients of a commercial Terfenol-D rod under controlled conditions.

  19. The Function of the Novel Mechanical Activated Ion Channel Piezo1 in the Human Osteosarcoma Cells

    OpenAIRE

    Jiang, Long; Zhao, Yi-ding; Chen, Wei-xiang

    2017-01-01

    Background The Piezo1 protein ion channel is a novel mechanical activated ion channel which is related to mechanical signal transduction. However, the function of the mechanically activated ion channel Piezo1 had not been explored. In this study, we explored the function of the Piezo1 ion channel in human osteosarcoma (OS) cells related to apoptosis, invasion, and the cell proliferation. Material/Methods Reverse transcription polymerase chain reaction (RT-PCR) and western-blotting were used t...

  20. The relation of appraisal, coping efforts, and acuteness of trauma to PTS symptoms among former political prisoners.

    Science.gov (United States)

    Kanninen, Katri; Punamäki, Raija-Leena; Qouta, Samir

    2002-06-01

    We examined how trauma-specific appraisals and coping efforts mediate between traumatic experiences, acuteness of trauma, and length of imprisonment and posttraumatic stress symptoms (PTS) among 103 Palestinian former political prisoners. The findings provide support for both direct and mediated models of trauma. The acuteness of trauma (time since release), appraisal of prison experience as harmful and involving loss, and use of both emotion- and problem-focused coping efforts were associated with high levels of PTS symptoms. Torture and ill-treatment had a direct association with intrusion, and recent release from prison with avoidance symptoms. Acuteness of trauma turned out to be important in the coping and symptom association: emotion-focused coping was associated with a low level of PTS symptoms in the long run, whereas problem-focused coping was associated with a low level of PTS symptoms in the short run.

  1. Tysnd1 deficiency in mice interferes with the peroxisomal localization of PTS2 enzymes, causing lipid metabolic abnormalities and male infertility.

    Directory of Open Access Journals (Sweden)

    Yumi Mizuno

    Full Text Available Peroxisomes are subcellular organelles involved in lipid metabolic processes, including those of very-long-chain fatty acids and branched-chain fatty acids, among others. Peroxisome matrix proteins are synthesized in the cytoplasm. Targeting signals (PTS or peroxisomal targeting signal at the C-terminus (PTS1 or N-terminus (PTS2 of peroxisomal matrix proteins mediate their import into the organelle. In the case of PTS2-containing proteins, the PTS2 signal is cleaved from the protein when transported into peroxisomes. The functional mechanism of PTS2 processing, however, is poorly understood. Previously we identified Tysnd1 (Trypsin domain containing 1 and biochemically characterized it as a peroxisomal cysteine endopeptidase that directly processes PTS2-containing prethiolase Acaa1 and PTS1-containing Acox1, Hsd17b4, and ScpX. The latter three enzymes are crucial components of the very-long-chain fatty acids β-oxidation pathway. To clarify the in vivo functions and physiological role of Tysnd1, we analyzed the phenotype of Tysnd1(-/- mice. Male Tysnd1(-/- mice are infertile, and the epididymal sperms lack the acrosomal cap. These phenotypic features are most likely the result of changes in the molecular species composition of choline and ethanolamine plasmalogens. Tysnd1(-/- mice also developed liver dysfunctions when the phytanic acid precursor phytol was orally administered. Phyh and Agps are known PTS2-containing proteins, but were identified as novel Tysnd1 substrates. Loss of Tysnd1 interferes with the peroxisomal localization of Acaa1, Phyh, and Agps, which might cause the mild Zellweger syndrome spectrum-resembling phenotypes. Our data established that peroxisomal processing protease Tysnd1 is necessary to mediate the physiological functions of PTS2-containing substrates.

  2. A self-adaption compensation control for hysteresis nonlinearity in piezo-actuated stages based on Pi-sigma fuzzy neural network

    Science.gov (United States)

    Xu, Rui; Zhou, Miaolei

    2018-04-01

    Piezo-actuated stages are widely applied in the high-precision positioning field nowadays. However, the inherent hysteresis nonlinearity in piezo-actuated stages greatly deteriorates the positioning accuracy of piezo-actuated stages. This paper first utilizes a nonlinear autoregressive moving average with exogenous inputs (NARMAX) model based on the Pi-sigma fuzzy neural network (PSFNN) to construct an online rate-dependent hysteresis model for describing the hysteresis nonlinearity in piezo-actuated stages. In order to improve the convergence rate of PSFNN and modeling precision, we adopt the gradient descent algorithm featuring three different learning factors to update the model parameters. The convergence of the NARMAX model based on the PSFNN is analyzed effectively. To ensure that the parameters can converge to the true values, the persistent excitation condition is considered. Then, a self-adaption compensation controller is designed for eliminating the hysteresis nonlinearity in piezo-actuated stages. A merit of the proposed controller is that it can directly eliminate the complex hysteresis nonlinearity in piezo-actuated stages without any inverse dynamic models. To demonstrate the effectiveness of the proposed model and control methods, a set of comparative experiments are performed on piezo-actuated stages. Experimental results show that the proposed modeling and control methods have excellent performance.

  3. Progress in piezotronics and piezo-phototronics

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhong Lin [School of Material Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States)

    2012-09-04

    The fundamental principle of piezotronics and piezo-phototronics were introduced by Wang in 2007 and 2010, respectively. Due to the polarization of ions in a crystal that has non-central symmetry in materials such as the wurtzite structured ZnO, GaN and InN, a piezoelectric potential (piezopotential) is created in the crystal by applying a stress. Owing to the simultaneous possession of piezoelectricity and semiconductor properties, the piezopotential created in the crystal has a strong effect on the carrier transport at the interface/junction. Piezotronics is about the devices fabricated using the piezopotential as a ''gate'' voltage to tune/control charge carrier transport at a contact or junction. The piezo-phototronic effect is to use the piezopotential to control the carrier generation, transport, separation and/or recombination for improving the performance of optoelectronic devices, such as photon detector, solar cell and LED. This manuscript reviews the updated progress in the two new fields. A perspective is given about their potential applications in sensors, human-silicon technology interfacing, MEMS, nanorobotics and energy sciences. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Design of 12-phase, 2-stage Harmonic Rejection Mixer for TV Tuners

    Directory of Open Access Journals (Sweden)

    D. Lee

    2016-06-01

    Full Text Available A two-stage 12-phase harmonic rejection mixer (HRM for TV tuners is proposed in order to reject the local oscillator (LO harmonics up to the ninth order. The proposed weighing scheme for 12-phase, 2-stage harmonic mixing can reduce the harmonic rejection (HR sensitivity to the amplitude error caused by irrational numbers such as . To verify this HR, the 2-stage HR circuit is designed with baseband gm weighting in order to save power and improve the HR ratios without calibration. The proposed HRM achieves the third to ninth worst HR ratios, more than 55 dB, according to Monte Carlo simulations. It consumes 6.5 mA under a 2.5 V supply voltage.

  5. The structure of a conserved piezo channel domain reveals a topologically distinct β sandwich fold.

    Science.gov (United States)

    Kamajaya, Aron; Kaiser, Jens T; Lee, Jonas; Reid, Michelle; Rees, Douglas C

    2014-10-07

    Piezo has recently been identified as a family of eukaryotic mechanosensitive channels composed of subunits containing over 2,000 amino acids, without recognizable sequence similarity to other channels. Here, we present the crystal structure of a large, conserved extramembrane domain located just before the last predicted transmembrane helix of C. elegans PIEZO, which adopts a topologically distinct β sandwich fold. The structure was also determined of a point mutation located on a conserved surface at the position equivalent to the human PIEZO1 mutation found in dehydrated hereditary stomatocytosis patients (M2225R). While the point mutation does not change the overall domain structure, it does alter the surface electrostatic potential that may perturb interactions with a yet-to-be-identified ligand or protein. The lack of structural similarity between this domain and any previously characterized fold, including those of eukaryotic and bacterial channels, highlights the distinctive nature of the Piezo family of eukaryotic mechanosensitive channels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Control Software for Piezo Stepping Actuators

    Science.gov (United States)

    Shields, Joel F.

    2013-01-01

    A control system has been developed for the Space Interferometer Mission (SIM) piezo stepping actuator. Piezo stepping actuators are novel because they offer extreme dynamic range (centimeter stroke with nanometer resolution) with power, thermal, mass, and volume advantages over existing motorized actuation technology. These advantages come with the added benefit of greatly reduced complexity in the support electronics. The piezo stepping actuator consists of three fully redundant sets of piezoelectric transducers (PZTs), two sets of brake PZTs, and one set of extension PZTs. These PZTs are used to grasp and move a runner attached to the optic to be moved. By proper cycling of the two brake and extension PZTs, both forward and backward moves of the runner can be achieved. Each brake can be configured for either a power-on or power-off state. For SIM, the brakes and gate of the mechanism are configured in such a manner that, at the end of the step, the actuator is in a parked or power-off state. The control software uses asynchronous sampling of an optical encoder to monitor the position of the runner. These samples are timed to coincide with the end of the previous move, which may consist of a variable number of steps. This sampling technique linearizes the device by avoiding input saturation of the actuator and makes latencies of the plant vanish. The software also estimates, in real time, the scale factor of the device and a disturbance caused by cycling of the brakes. These estimates are used to actively cancel the brake disturbance. The control system also includes feedback and feedforward elements that regulate the position of the runner to a given reference position. Convergence time for smalland medium-sized reference positions (less than 200 microns) to within 10 nanometers can be achieved in under 10 seconds. Convergence times for large moves (greater than 1 millimeter) are limited by the step rate.

  7. Mastication noise reduction method for fully implantable hearing aid using piezo-electric sensor.

    Science.gov (United States)

    Na, Sung Dae; Lee, Gihyoun; Wei, Qun; Seong, Ki Woong; Cho, Jin Ho; Kim, Myoung Nam

    2017-07-20

    Fully implantable hearing devices (FIHDs) can be affected by generated biomechanical noise such as mastication noise. To reduce the mastication noise using a piezo-electric sensor, the mastication noise is measured with the piezo-electric sensor, and noise reduction is practiced by the energy difference. For the experiment on mastication noise, a skull model was designed using artificial skull model and a piezo-electric sensor that can measure the vibration signals better than other sensors. A 1 kHz pure-tone sound through a standard speaker was applied to the model while the lower jawbone of the model was moved in a masticatory fashion. The correlation coefficients and signal-to-noise ratio (SNR) before and after application of the proposed method were compared. It was found that the signal-to-noise ratio and correlation coefficients increased by 4.48 dB and 0.45, respectively. The mastication noise is measured by piezo-electric sensor as the mastication noise that occurred during vibration. In addition, the noise was reduced by using the proposed method in conjunction with MATLAB. In order to confirm the performance of the proposed method, the correlation coefficients and signal-to-noise ratio before and after signal processing were calculated. In the future, an implantable microphone for real-time processing will be developed.

  8. Piezo pump and pressurized circuit provided therewith

    NARCIS (Netherlands)

    Van Es, Johannes; Wits, Wessel Willems

    2015-01-01

    A piezo pump for use in a pressurized circuit includes a pump chamber with an inlet provided with a one way inlet valve, for connection to a feeding line of the pressurized circuit and an outlet provided with a one way outlet valve, for connection to a discharge line of the pressurized circuit and a

  9. Analogy between dynamics of thermo-rheological and piezo-rheological pendulums

    International Nuclear Information System (INIS)

    Hedrih, K

    2008-01-01

    The constitutive stress-strain relations of the standard thermo-rheological and piezo-rheological hereditary element in differential form as well as in two different integro-differential forms are defined. The considered problem of a thermo-rheological hereditary discrete system nonlinear dynamics in the form of thermo-rheological double pendulum system with coupled pendulums gets the significance of two constrained bodies in plane motion problem, as a problem important for studying a sensor dynamics or actuator dynamics in active structure dynamics. System of the averaged equations in the first approximation for amplitudes and phases are derived and qualitatively analyzed. Analogy between nonlinear dynamics of the double pendulum systems with thermo-rheological and piezo-rheological properties between pendulums is pointed out

  10. Piezo type mechanosensitive ion channel component 1 functions as a regulator of the cell fate determination of mesenchymal stem cells.

    Science.gov (United States)

    Sugimoto, Asuna; Miyazaki, Aya; Kawarabayashi, Keita; Shono, Masayuki; Akazawa, Yuki; Hasegawa, Tomokazu; Ueda-Yamaguchi, Kimiko; Kitamura, Takamasa; Yoshizaki, Keigo; Fukumoto, Satoshi; Iwamoto, Tsutomu

    2017-12-18

    The extracellular environment regulates the dynamic behaviors of cells. However, the effects of hydrostatic pressure (HP) on cell fate determination of mesenchymal stem cells (MSCs) are not clearly understood. Here, we established a cell culture chamber to control HP. Using this system, we found that the promotion of osteogenic differentiation by HP is depend on bone morphogenetic protein 2 (BMP2) expression regulated by Piezo type mechanosensitive ion channel component 1 (PIEZO1) in MSCs. The PIEZO1 was expressed and induced after HP loading in primary MSCs and MSC lines, UE7T-13 and SDP11. HP and Yoda1, an activator of PIEZO1, promoted BMP2 expression and osteoblast differentiation, whereas inhibits adipocyte differentiation. Conversely, PIEZO1 inhibition reduced osteoblast differentiation and BMP2 expression. Furthermore, Blocking of BMP2 function by noggin inhibits HP induced osteogenic maker genes expression. In addition, in an in vivo model of medaka with HP loading, HP promoted caudal fin ray development whereas inhibition of piezo1 using GsMTx4 suppressed its development. Thus, our results suggested that PIEZO1 is responsible for HP and could functions as a factor for cell fate determination of MSCs by regulating BMP2 expression.

  11. Diagnostics for Z-pinch implosion experiments on PTS

    Energy Technology Data Exchange (ETDEWEB)

    Ren, X. D., E-mail: amosrxd@163.com; Huang, X. B., E-mail: amosrxd@163.com; Zhou, S. T., E-mail: amosrxd@163.com; Zhang, S. Q., E-mail: amosrxd@163.com; Dan, J. K., E-mail: amosrxd@163.com; Li, J., E-mail: amosrxd@163.com; Cai, H. C., E-mail: amosrxd@163.com; Wang, K. L., E-mail: amosrxd@163.com; Ouyang, K., E-mail: amosrxd@163.com; Xu, Q., E-mail: amosrxd@163.com; Duan, S. C., E-mail: amosrxd@163.com; Chen, G. H., E-mail: amosrxd@163.com; Wang, M., E-mail: amosrxd@163.com; Feng, S. P., E-mail: amosrxd@163.com; Yang, L. B., E-mail: amosrxd@163.com; Xie, W. P., E-mail: amosrxd@163.com; Deng, J. J., E-mail: amosrxd@163.com [Key Lab of Pulsed Power, Institute of Fluid Physics, CAEP, P.O. Box 919-108, Mianyang, Sichuan 621999 (China)

    2014-12-15

    The preliminary experiments of wire array implosion were performed on PTS, a 10 MA z-pinch driver with a 70 ns rise time. A set of diagnostics have been developed and fielded on PTS to study pinch physics and implosion dynamics of wire array. Radiated power measurement for soft x-rays was performed by multichannel filtered x-ray diode array, and flat spectral responses x-ray diode detector. Total x-ray yield was measured by a calibrated, unfiltered nickel bolometer which was also used to obtain pinch power. Multiple time-gated pinhole cameras were used to produce spatial-resolved images of x-ray self-emission from plasmas. Two time-integrated pinhole cameras were used respectively with 20-μm Be filter and with multilayer mirrors to record images produced by >1-keV and 277±5 eV self-emission. An optical streak camera was used to produce radial implosion trajectories, and an x-ray streak camera paired with a horizontal slit was used to record a continuous time-history of emission with one-dimensional spatial resolution. A frequency-doubled Nd:YAG laser (532 nm) was used to produce four frame laser shadowgraph images with 6 ns time interval. We will briefly describe each of these diagnostics and present some typical results from them.

  12. No hypothyroidism after I-131 therapy in pts with toxic nodular goiter, treated under combined thyreostatic, thyreomimetic medication

    International Nuclear Information System (INIS)

    Giubbini, R.; Panarotto, M.B.; Paghera, B.; Pagliaini, R.; Pajoro, U.; Pizzocaro, C.; Rossini, P.L.; Terzi, A.; Maira, G.

    2002-01-01

    Background. Treatment of toxic nodular goiter with 131-I is generally satisfactory and will cause a reversion of hyperthyroidism. To avoid the risk of thyrotoxic storm I-131 therapy is usually performed after pre-treatment with antithyroid drugs, which causes a TSH increase and functional recruitment of previously inhibited normal thyroid tissue. In this functional state both autonomous nodule(s) and normal tissue are irradiated after I-131 administration. This may be the reason of late hypothyroidism occurring in 15-25% of Pts. Aim of the study was the evaluation of a different pre-treatment modality with combined methimazole (10-20 mg) and Triiodo-thyronine (T3 - 60 μg) in order to treat pts in euthyroid state with suppressed TSH. Study protocol. After diagnosis of hyperthyroidism with autonomous functioning tissue the pts were put under thyreostatic medication. Two months later TSH was checked and if >0.5% U.I the T3 treatment was associated. After two more months, the TSH level was checked again and, if suppressed, the pt received I-131 therapy. Study population. 93 pts (74f, 19m - age 75±10) were consecutively enrolled. 24 pts had a toxic nodular goiter and 69 a multi nodular one, respectively; they were evaluated at diagnosis, at pre-treatment, two months after therapy and at late follow-up (3.1 ± 3.5 yrs). Methods: 557±225 MBq of I-131 (according to uptake determinations and gland weight) were administered. Methymazole was discontinued 3 days before treatment whereas T3 was maintained during I-131 therapy. Results: Euthyroidism was achieved after the first treatment in 71% of pts. At late follow-up TSH values over the normal range were observed in only 4 pts (4.3% - however all 4 pts had TSH level below 6 I.U.). Summaries of FT3 and FT4 values are presented. Conclusions: The treatment of toxic nodular goiter under combined thyreostatic-thyreomimetic treatment is a safe, well tolerated and effective procedure allowing a 71% success at the first treatment

  13. A piezo-ring-on-chip microfluidic device for simple and low-cost mass spectrometry interfacing.

    Science.gov (United States)

    Tsao, Chia-Wen; Lei, I-Chao; Chen, Pi-Yu; Yang, Yu-Liang

    2018-02-12

    Mass spectrometry (MS) interfacing technology provides the means for incorporating microfluidic processing with post MS analysis. In this study, we propose a simple piezo-ring-on-chip microfluidic device for the controlled spraying of MALDI-MS targets. This device uses a low-cost, commercially-available ring-shaped piezoelectric acoustic atomizer (piezo-ring) directly integrated into a polydimethylsiloxane microfluidic device to spray the sample onto the MS target substrate. The piezo-ring-on-chip microfluidic device's design, fabrication, and actuation, and its pulsatile pumping effects were evaluated. The spraying performance was examined by depositing organic matrix samples onto the MS target substrate by using both an automatic linear motion motor, and manual deposition. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was performed to analyze the peptide samples on the MALDI target substrates. Using our technique, model peptides with 10 -6 M concentration can be successfully detected. The results also indicate that the piezo-ring-on-chip approach forms finer matrix crystals and presents better MS signal uniformity with little sample consumption compared to the conventional pipetting method.

  14. H∞ control of piezo actuated tilting mirror mechanism

    NARCIS (Netherlands)

    Van Dijk, J.

    2015-01-01

    In here the high bandwidth (2000 Hz.) feedback control of a precision mechanisms driven by a piezo actuator demanding a high absolute accuracy is discussed. The mechanism considered is rotating a mirror for laser bundle manipulation. It will be shown that a loopshaping controller design using the

  15. Structure-based membrane dome mechanism for Piezo mechanosensitivity.

    Science.gov (United States)

    Guo, Yusong R; MacKinnon, Roderick

    2017-12-12

    Mechanosensitive ion channels convert external mechanical stimuli into electrochemical signals for critical processes including touch sensation, balance, and cardiovascular regulation. The best understood mechanosensitive channel, MscL, opens a wide pore, which accounts for mechanosensitive gating due to in-plane area expansion. Eukaryotic Piezo channels have a narrow pore and therefore must capture mechanical forces to control gating in another way. We present a cryo-EM structure of mouse Piezo1 in a closed conformation at 3.7Å-resolution. The channel is a triskelion with arms consisting of repeated arrays of 4-TM structural units surrounding a pore. Its shape deforms the membrane locally into a dome. We present a hypothesis in which the membrane deformation changes upon channel opening. Quantitatively, membrane tension will alter gating energetics in proportion to the change in projected area under the dome. This mechanism can account for highly sensitive mechanical gating in the setting of a narrow, cation-selective pore. © 2017, Guo et al.

  16. A new dimension for piezo actuators: free-form out-of-plane displacement of single piezo layers

    International Nuclear Information System (INIS)

    Wapler, Matthias C; Brunne, Jens; Wallrabe, Ulrike

    2013-01-01

    We present a controlled mode of ‘topological’ displacement of homogeneous piezo films that arises solely from an inhomogeneous in-plane strain due to an inhomogeneous polarization. For the rotationally symmetric case, we develop a theoretical model that analytically relates the shape of the displacement to the polarization for the cases of in-plane and out-of-plane polarization. This is verified experimentally for several examples, and we further demonstrate controlled asymmetric deformations. (fast track communication)

  17. Measuring leg movements during sleep using accelerometry: comparison with EMG and piezo-electric scored events.

    Science.gov (United States)

    Terrill, Philip I; Leong, Matthew; Barton, Katrina; Freakley, Craig; Downey, Carl; Vanniekerk, Mark; Jorgensen, Greg; Douglas, James

    2013-01-01

    Periodic Limb Movements during Sleep (PLMS) can cause significant disturbance to sleep, resulting in daytime sleepiness and reduced quality of life. In conventional clinical practice, PLMS are measured using overnight electromyogram (EMG) of the tibialis anterior muscle, although historically they have also been measured using piezo-electric gauges placed over the muscle. However, PLMS counts (PLM index) do not correlate well with clinical symptomology. In this study, we propose that because EMG and piezo derived signals measure muscle activation rather than actual movement, they may count events with no appreciable movement of the limb and therefore no contribution to sleep disturbance. The aim of this study is thus to determine the percentage of clinically scored limb movements which are not associated with movement of the great toe measured using accelerometry. 9 participants were studied simultaneously with an overnight diagnostic polysomnogram (including EMG and piezo instrumentation of the right leg) and high temporal resolution accelerometry of the right great toe. Limb movements were scored, and peak acceleration during each scored movement was quantified. Across the participant population, 54.9% (range: 26.7-76.3) and 39.0% (range: 4.8-69.6) of limb movements scored using piezo and EMG instrumentation respectively, were not associated with toe movement measured with accelerometry. If sleep disturbance is the consequence of the limb movements, these results may explain why conventional piezo or EMG derived PLMI is poorly correlated with clinical symptomology.

  18. Androgen deprivation does predict bNED survival in unfavorable prostate cancer PTS treated with external beam radiation therapy

    International Nuclear Information System (INIS)

    Anderson, Penny R.; Hanlon, Alexandra L.; Hanks, Gerald E.

    1996-01-01

    Purpose: Cooperative groups have investigated the outcome of androgen deprivation therapy combined with radiation therapy in prostate cancer pts with variable prerx prognostic indicators. This report describes an objective means of selecting pts for adjuvant hormonal therapy by examining bNED survival for groups of pts with specific prognostic indicators treated with adjuvant hormones (RT+H) vs matched controls treated with radiation therapy alone (RT). In addition, this report shows the 5-yr bNED survival for pts selected by this method for RT+H vs RT alone. Further, bNED survival is assessed multivariately according to treatment (RT+H vs RT) and predetermined prognostic treatment and prerx covariates. Materials and Methods: From (10(88)) to (12(94)), 684 T1-T3 NXM0 pts with known prerx PSA level were treated at Fox Chase Cancer Center. 568 of those pts were treated with RT alone while 116 were treated with RT+H. Table 1 lists the patient distributions for each of the putative prognostic factors indicative of bNED survival. We compare actuarial bNED survival rates according to treatment group within each of the prognostic groups. bNED survival is also compared for the two treatment groups using 107 RT+H pts and 107 matched (by stage, grade, and prerx PSA) controls randomly selected from the RT alone group. bNED survival for the 214 pts is then analyzed multivariately using stepwise Cox regression to determine independent predictors of outcome. Covariates considered for entry into the model included stage, grade, prerx PSA, treatment (RT vs RT+H), and center of prostate dose. bNED failure is defined as PSA ≥1.5 ngm/ml and rising on two consective determinations. The median follow-up is 30 mos (2 to 90 mos). Results: Table 1 presents three-year bNED actuarial survival rates according to treatment group for prerx PSA, gleason score, and stage groups. It is apparent that the T2C/T3, gleason 7-10, and the prerx PSA > 15 ngm/ml groups of pts benefit from hormonal

  19. Influence of military sexual assault and other military stressors on substance use disorder and PTS symptomology in female military veterans.

    Science.gov (United States)

    Yalch, Matthew M; Hebenstreit, Claire L; Maguen, Shira

    2018-05-01

    Servicewomen exposed to traumatic stressors over the course of their military service are at increased risk of developing symptoms of substance use disorder (SUD) and posttraumatic stress (PTS). They are also at risk for exposure to military sexual assault (MSA), which is also associated with SUD and PTS symptomology. Research is unclear about the incremental contributions of different forms of traumatic stressors on co-occurring SUD and PTS symptomology. In this study we examined the independent and combined effects of MSA and other military stressors on SUD and PTS symptomology in a sample of female veterans (N=407). Results indicate that MSA and other military stressors exhibit incremental effects on SUD and PTS symptomology. Results further suggest that women exposed to both MSA and other military stressors are at increased risk for developing co-occurring SUD and PTSD. These findings extend previous research on comorbid SUD and PTSD, highlighting the cumulative effects of traumatic stressors on posttraumatic psychopathology, and have implications for future research and clinical practice with female veterans. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The dynamics of the piezo inkjet printhead operation

    NARCIS (Netherlands)

    Wijshoff, H.M.A.

    2010-01-01

    The operation of a piezo inkjet printhead involves a chain of processes in many physical domains at different length scales. The final goal is the formation of droplets of all kinds of fluids with any desired volume, velocity, and a reliability as high as possible. The physics behind the chain of

  1. A study on nozzle flow and spray characteristics of piezo injector for next generation high response injection

    International Nuclear Information System (INIS)

    Lee, Jin Wook; Min, Kyoung Doug

    2006-01-01

    Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(Volume Of Fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response in a piezo-driven injector were reflected to spray development in agreement with the experimental spray images

  2. The methylotrophic yeast Hansenula polymorpha contains an inducible import pathway for peroxisomal matrix proteins with an N-terminal targeting signal (PTS2 proteins)

    NARCIS (Netherlands)

    Faber, Klaas Nico; Haima, Pieter; Gietl, Christine; Harder, Willem; Ab, Geert; Veenhuis, Marten

    1994-01-01

    Two main types of peroxisomal targeting signals have been identified that reside either at the extreme C terminus (PTS1) or the N terminus (PTS2) of the protein. In the methylotrophic yeast Hansenula polymorpha the majority of peroxisomal matrix proteins are of the PTS1 type. Thus far, for H.

  3. Lateral bending of tapered piezo-semiconductive nanostructures for ultra-sensitive mechanical force to voltage conversion.

    Science.gov (United States)

    Araneo, Rodolfo; Falconi, Christian

    2013-07-05

    Quasi-1D piezoelectric nanostructures may offer unprecedented sensitivity for transducing minuscule input mechanical forces into high output voltages due to both scaling laws and increased piezoelectric coefficients. However, until now both theoretical and experimental studies have suggested that, for a given mechanical force, lateral bending of piezoelectric nanowires results in lower output electric potentials than vertical compression. Here we demonstrate that this result only applies to nanostructures with a constant cross-section. Moreover, though it is commonly believed that the output electric potential of a strained piezo-semiconductive device can only be reduced by the presence of free charges, we show that the output piezopotential of laterally bent tapered nanostructures, with typical doping levels and very small input forces, can be even increased up to two times by free charges.Our analyses confirm that, though not optimal for piezoelectric energy harvesting, lateral bending of tapered nanostructures with typical doping levels can be ideal for transducing tiny input mechanical forces into high and accessible piezopotentials. Our results provide guidelines for designing high-performance piezo-nano-devices for energy harvesting, mechanical sensing, piezotronics, piezo-phototronics, and piezo-controlled chemical reactions, among others.

  4. Lateral bending of tapered piezo-semiconductive nanostructures for ultra-sensitive mechanical force to voltage conversion

    International Nuclear Information System (INIS)

    Araneo, Rodolfo; Falconi, Christian

    2013-01-01

    Quasi-1D piezoelectric nanostructures may offer unprecedented sensitivity for transducing minuscule input mechanical forces into high output voltages due to both scaling laws and increased piezoelectric coefficients. However, until now both theoretical and experimental studies have suggested that, for a given mechanical force, lateral bending of piezoelectric nanowires results in lower output electric potentials than vertical compression. Here we demonstrate that this result only applies to nanostructures with a constant cross-section. Moreover, though it is commonly believed that the output electric potential of a strained piezo-semiconductive device can only be reduced by the presence of free charges, we show that the output piezopotential of laterally bent tapered nanostructures, with typical doping levels and very small input forces, can be even increased up to two times by free charges. Our analyses confirm that, though not optimal for piezoelectric energy harvesting, lateral bending of tapered nanostructures with typical doping levels can be ideal for transducing tiny input mechanical forces into high and accessible piezopotentials. Our results provide guidelines for designing high-performance piezo-nano-devices for energy harvesting, mechanical sensing, piezotronics, piezo-phototronics, and piezo-controlled chemical reactions, among others. (paper)

  5. The influence of finite-length flaw effects on PTS analyses

    International Nuclear Information System (INIS)

    Keeney-Walker, J.; Dickson, T.L.

    1993-01-01

    Current licensing issues within the nuclear industry dictate a need to investigate the effects of cladding on the extension of small finite-length cracks near the inside surface of a vessel. Because flaws having depths of the order of the combined clad and heat affected zone thickness dominate the frequency distribution of flaws, their initiation probabilities can govern calculated vessel failure probabilities. Current pressurized-thermal-shock (PTS) analysis computer programs recognize the influence of the inner-surface cladding layer in the heat transfer and stress analysis models, but assume the cladding fracture toughness is the same as that for the base material. The programs do not recognize the influence cladding may have in inhibiting crack initiation and propagation of shallow finite-length surface flaws. Limited experimental data and analyses indicate the cladding can inhibit the propagation of certain shallow flaws. This paper describes an analytical study which was carried out to determine (1) the minimum flaw depth for crack initiation under PTS loading for semicircular surface flaws in a clad reactor pressure vessel and (2) the impact, in terms of the conditional probability of vessel failure, of using a semicircular surface flaw as the initial flaw and assuming that the flaw cannot propagate in the cladding. The analytical results indicate that for initiation a much deeper critical crack depth is required for the finite-length flaw than for the infinite-length flaw, except for the least severe transient. The minimum flaw depths required for crack initiation from the finite-length flaw analyses were incorporated into a modified version of the OCA-P code. The modified code was applied to the analysis of selected PTS transients, and the results produced a substantial decrease in the conditional probability of failure. This initial study indicates a significant effect on probabilistic fracture analyses by incorporating finite-length flaw results

  6. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  7. Lower blastocyst quality after conventional vs. Piezo ICSI in the horse reflects delayed sperm component remodeling and oocyte activation.

    Science.gov (United States)

    Salgado, R M; Brom-de-Luna, J G; Resende, H L; Canesin, H S; Hinrichs, Katrin

    2018-04-10

    The aim of this study was to evaluate the differential effects of conventional and Piezo-driven ICSI on blastocyst development, and on sperm component remodeling and oocyte activation, in an equine model. In vitro-matured equine oocytes underwent conventional (Conv) or Piezo ICSI, the latter utilizing fluorocarbon ballast. Blastocyst development was compared between treatments to validate the model. Then, oocytes were fixed at 0, 6, or 18 h after injection, and stained for the sperm tail, acrosome, oocyte cortical granules, and chromatin. These parameters were compared between injection techniques and between sham-injected and sperm-injected oocytes among time periods. Blastocyst rates were 39 and 40%. The nucleus number was lower, and the nuclear fragmentation rate was higher, in blastocysts produced by Conv. Cortical granule loss started at 0H after both sperm and sham injection. The acrosome was present at 0H in both ICSI treatments, and persisted to 18H in significantly more Conv than Piezo oocytes (72 vs. 21%). Sperm head area was unchanged at 6H in Conv but significantly increased at this time in Piezo; correspondingly, at 6H significantly more Conv than Piezo oocytes remained at MII (80 vs. 9.5%). Sham injection did not induce significant meiotic resumption. These data show that Piezo ICSI is associated with more rapid sperm component remodeling and oocyte meiotic resumption after sperm injection than is conventional ICSI, and with higher embryo quality at the blastocyst stage. This suggests that there is value in exploring the Piezo technique, utilized with a non-toxic fluorocarbon ballast, for use in clinical human ICSI.

  8. A study on nozzle flow and spray characteristics of piezo injector for next generation high response injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Wook [Korea Institue of Machinery and Materials, Daejeon (Korea, Republic of); Min, Kyoung Doug [Seoul National University, Seoul (Korea, Republic of)

    2006-06-15

    Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(Volume Of Fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response in a piezo-driven injector were reflected to spray development in agreement with the experimental spray images.

  9. Piezo films with adjustable anisotropic strain for bending actuators with tunable bending profiles

    International Nuclear Information System (INIS)

    Wapler, Matthias C; Stürmer, Moritz; Brunne, Jens; Wallrabe, Ulrike

    2014-01-01

    We present a method to produce in-plane polarized piezo films with a freely adjustable ratio of the strains in orthogonal in-plane directions. They can be used in piezo bending actuators with a tunable curvature profile. The strains are obtained as mean strains from a periodic polarization pattern produced by a suitable doubly interdigitated electrode structure. This mechanism is demonstrated for several examples using PZT sheets. We further discuss how this tuning and the parameters of the electrode layout affect the overall magnitude of the displacement. (paper)

  10. Strongly bound excitons in monolayer PtS2 and PtSe2

    KAUST Repository

    Sajjad, M.; Singh, Nirpendra; Schwingenschlö gl, Udo

    2018-01-01

    Based on first-principles calculations, the structural, electronic, and optical properties of monolayers PtS2 and PtSe2 are investigated. The bond stiffnesses and elastic moduli are determined by means of the spring constants and strain

  11. Testing of Piezo-Actuated Glass Micro-Membranes by Optical Low-Coherence Reflectometry.

    Science.gov (United States)

    Merlo, Sabina; Poma, Paolo; Crisà, Eleonora; Faralli, Dino; Soldo, Marco

    2017-02-25

    In this work, we have applied optical low-coherence reflectometry (OLCR), implemented with infra-red light propagating in fiberoptic paths, to perform static and dynamic analyses on piezo-actuated glass micro-membranes. The actuator was fabricated by means of thin-film piezoelectric MEMS technology and was employed for modifying the micro-membrane curvature, in view of its application in micro-optic devices, such as variable focus micro-lenses. We are here showing that OLCR incorporating a near-infrared superluminescent light emitting diode as the read-out source is suitable for measuring various parameters such as the micro-membrane optical path-length, the membrane displacement as a function of the applied voltage (yielding the piezo-actuator hysteresis) as well as the resonance curve of the fundamental vibration mode. The use of an optical source with short coherence-time allows performing interferometric measurements without spurious resonance effects due to multiple parallel interfaces of highly planar slabs, furthermore selecting the plane/layer to be monitored. We demonstrate that the same compact and flexible setup can be successfully employed to perform spot optical measurements for static and dynamic characterization of piezo-MEMS in real time.

  12. Piezo-optic tensor of crystals from quantum-mechanical calculations.

    Science.gov (United States)

    Erba, A; Ruggiero, M T; Korter, T M; Dovesi, R

    2015-10-14

    An automated computational strategy is devised for the ab initio determination of the full fourth-rank piezo-optic tensor of crystals belonging to any space group of symmetry. Elastic stiffness and compliance constants are obtained as numerical first derivatives of analytical energy gradients with respect to the strain and photo-elastic constants as numerical derivatives of analytical dielectric tensor components, which are in turn computed through a Coupled-Perturbed-Hartree-Fock/Kohn-Sham approach, with respect to the strain. Both point and translation symmetries are exploited at all steps of the calculation, within the framework of periodic boundary conditions. The scheme is applied to the determination of the full set of ten symmetry-independent piezo-optic constants of calcium tungstate CaWO4, which have recently been experimentally reconstructed. Present calculations unambiguously determine the absolute sign (positive) of the π61 constant, confirm the reliability of 6 out of 10 experimentally determined constants and provide new, more accurate values for the remaining 4 constants.

  13. Piezo-Electrochemical Energy Harvesting with Lithium-Intercalating Carbon Fibers.

    Science.gov (United States)

    Jacques, Eric; Lindbergh, Göran; Zenkert, Dan; Leijonmarck, Simon; Kjell, Maria Hellqvist

    2015-07-01

    The mechanical and electrochemical properties are coupled through a piezo-electrochemical effect in Li-intercalated carbon fibers. It is demonstrated that this piezo-electrochemical effect makes it possible to harvest electrical energy from mechanical work. Continuous polyacrylonitrile-based carbon fibers that can work both as electrodes for Li-ion batteries and structural reinforcement for composites materials are used in this study. Applying a tensile force to carbon fiber bundles used as Li-intercalating electrodes results in a response of the electrode potential of a few millivolts which allows, at low current densities, lithiation at higher electrode potential than delithiation. More electrical energy is thereby released from the cell at discharge than provided at charge, harvesting energy from the mechanical work of the applied force. The measured harvested specific electrical power is in the order of 1 μW/g for current densities in the order of 1 mA/g, but this has a potential of being increased significantly.

  14. Fracture mechanics analysis and evaluation for the RPV of the Chinese Qinshan 300 MW NPP and PTS

    International Nuclear Information System (INIS)

    He Yinbiao; Isozaki, Toshikuni

    2000-03-01

    One of the most severe accident conditions of a reactor pressure vessel (RPV) in service is the loss of coolant accident (LOCA). Cold safety injection water is pumped into the downcomer of the RPV through inlet nozzles, while the internal pressure may remain at high level. Such an accident is called pressurized thermal shock (PTS) transient according to 10 CFR 50.61 definition. This paper illustrates the fracture mechanics analysis for the existing RPV of the Chinese Qinshan 300 MW nuclear power plant (NPP) under the postulated PTS transients that include SB-LOCA, LB-LOCA of Qinshan NPP and Rancho Seco transients. 3-D models with the flaw depth range a/w=0.05∼0.9 (a: flaw depth; w: wall thickness) were used to probe what kind of flaw and what kind of transient are most dangerous for the RPV in the end of life (EOF). Both the elastic and elastic-plastic material models were used in the stress analysis and fracture mechanics analysis. The different types of flaw and the influence of the stainless steel cladding on the fracture analysis were investigated for different PTS transients. comparing with the material initiation crack toughness K IC , the fracture evaluation for the RPV in question under PTS transients are performed in this paper. (author)

  15. Piezo-Phototronic Effect Enhanced Flexible Solar Cells Based on n-ZnO/p-SnS Core-Shell Nanowire Array.

    Science.gov (United States)

    Zhu, Laipan; Wang, Longfei; Xue, Fei; Chen, Libo; Fu, Jianqiang; Feng, Xiaolong; Li, Tianfeng; Wang, Zhong Lin

    2017-01-01

    The piezo-phototronic effect is about the enhanced separation, transport, and recombination of the photogenerated carriers using the piezoelectric polarization charges present in piezoelectric-semiconductor materials. Here, it is presented that the piezo-phototronic effect can be effectively applied to improve the relative conversion efficiency of a flexible solar cell based on n-ZnO/p-SnS core-shell nanowire array for 37.3% under a moderate vertical pressure. The performance of the solar cell can be effectively enhanced by a gentle bending of the device, showing its potential for application in curly geometries. This study not only adds further understanding about the concept of increasing solar energy conversion efficiency via piezo-phototronic effect, but also demonstrates the great potential of piezo-phototronic effect in the application of large-scale, flexible, and lightweight nanowire array solar cells.

  16. Primary experimental results of wire-array Z-pinches on PTS

    Energy Technology Data Exchange (ETDEWEB)

    Huang, X. B., E-mail: caephxb2003@aliyun.com; Zhou, S. T., E-mail: caephxb2003@aliyun.com; Ren, X. D., E-mail: caephxb2003@aliyun.com; Dan, J. K., E-mail: caephxb2003@aliyun.com; Wang, K. L., E-mail: caephxb2003@aliyun.com; Zhang, S. Q., E-mail: caephxb2003@aliyun.com; Li, J., E-mail: caephxb2003@aliyun.com; Xu, Q., E-mail: caephxb2003@aliyun.com; Cai, H. C., E-mail: caephxb2003@aliyun.com; Duan, S. C., E-mail: caephxb2003@aliyun.com; Ouyang, K., E-mail: caephxb2003@aliyun.com; Chen, G. H., E-mail: caephxb2003@aliyun.com; Ji, C., E-mail: caephxb2003@aliyun.com; Wang, M., E-mail: caephxb2003@aliyun.com; Feng, S. P., E-mail: caephxb2003@aliyun.com; Yang, L. B., E-mail: caephxb2003@aliyun.com; Xie, W. P., E-mail: caephxb2003@aliyun.com; Deng, J. J., E-mail: caephxb2003@aliyun.com [Key Lab of Pulsed Power, Institute of Fluid Physics, CAEP, P.O. Box 919-108, Mianyang, Sichuan 621999 (China)

    2014-12-15

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a multiterawatt pulsed power driver, which can deliver a ∼10 MA, 70 ns rise-time (10%-90%) current to a short circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. In this paper, primary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 14.4-26.4 mm, and consisting of 132∼276 tungsten wires with 5∼10 μm in diameter. Multiple diagnostics were fielded to determine the characteristics of x-ray radiations and to obtain self-emitting images of imploding plasmas. X-ray power up to 80 TW with ∼3 ns FWMH is achieved by using nested wire arrays. The total x-ray energy exceeds 500 kJ and the peak radiation temperature is about 150 eV. Typical velocity of imploding plasmas goes around 3∼5×10{sup 7} cm/s and the radial convergence ratio is between 10 and 20.

  17. Piezopotential gated nanowire devices: Piezotronics and piezo-phototronics

    KAUST Repository

    Wang, Zhong Lin

    2010-12-01

    Due to the polarization of ions in a crystal that has non-central symmetry, a piezoelectric potential (piezopotential) is created in the crystal by applying a stress. For materials such as ZnO, GaN, and InN in the wurtzite structure family, the effect of piezopotential on the transport behavior of charge carriers is significant due to their multiple functionalities of piezoelectricity, semiconductor and photon excitation. By utilizing the advantages offered by these properties, a few new fields have been created. Electronics fabricated by using inner-crystal piezopotential as a "gate" voltage to tune/control the charge transport behavior is named piezotronics, with applications in strain/force/pressure triggered/controlled electronic devices, sensors and logic units. Piezo-phototronic effect is a result of three-way coupling among piezoelectricity, photonic excitation and semiconductor transport, which allows tuning and controlling of electro-optical processes by strain induced piezopotential. The objective of this review article is to introduce the fundamentals of piezotronics and piezo-phototronics and to give an updated progress about their applications in energy science and sensors. © 2010 Elsevier Ltd All rights reserved.

  18. Air Entrapment and Drop Formation in Piezo Inkjet Printing

    NARCIS (Netherlands)

    van der Bos, J.A.

    2011-01-01

    Piezo drop-on-demand (DOD) inkjet printers are used in an increasing number of applications for their reliable deposition of droplets onto a substrate. Droplets of a few picoliters are ejected from an ink jet nozzle at a frequency of up to 50 kHz. However, entrapment of an air microbubble into the

  19. Snoring detection using a piezo snoring sensor based on hidden Markov models.

    Science.gov (United States)

    Lee, Hyo-Ki; Lee, Jeon; Kim, Hojoong; Ha, Jin-Young; Lee, Kyoung-Joung

    2013-05-01

    This study presents a snoring detection method based on hidden Markov models (HMMs) using a piezo snoring sensor. Snoring is a major symptom of obstructive sleep apnea (OSA). In most sleep studies, snoring is detected with a microphone. Since these studies analyze the acoustic properties of snoring, they need to acquire data at high sampling rates, so a large amount of data should be processed. Recently, several sleep studies have monitored snoring using a piezo snoring sensor. However, an automatic method for snoring detection using a piezo snoring sensor has not been reported in the literature. This study proposed the HMM-based method to detect snoring using this sensor, which is attached to the neck. The data from 21 patients with OSA were gathered for training and test sets. The short-time Fourier transform and short-time energy were computed so they could be applied to HMMs. The data were classified as snoring, noise and silence according to their HMMs. As a result, the sensitivity and the positive predictivity values were 93.3% and 99.1% for snoring detection, respectively. The results demonstrated that the method produced simple, portable and user-friendly detection tools that provide an alternative to the microphone-based method.

  20. Snoring detection using a piezo snoring sensor based on hidden Markov models

    International Nuclear Information System (INIS)

    Lee, Hyo-Ki; Lee, Jeon; Lee, Kyoung-Joung; Kim, Hojoong; Ha, Jin-Young

    2013-01-01

    This study presents a snoring detection method based on hidden Markov models (HMMs) using a piezo snoring sensor. Snoring is a major symptom of obstructive sleep apnea (OSA). In most sleep studies, snoring is detected with a microphone. Since these studies analyze the acoustic properties of snoring, they need to acquire data at high sampling rates, so a large amount of data should be processed. Recently, several sleep studies have monitored snoring using a piezo snoring sensor. However, an automatic method for snoring detection using a piezo snoring sensor has not been reported in the literature. This study proposed the HMM-based method to detect snoring using this sensor, which is attached to the neck. The data from 21 patients with OSA were gathered for training and test sets. The short-time Fourier transform and short-time energy were computed so they could be applied to HMMs. The data were classified as snoring, noise and silence according to their HMMs. As a result, the sensitivity and the positive predictivity values were 93.3% and 99.1% for snoring detection, respectively. The results demonstrated that the method produced simple, portable and user-friendly detection tools that provide an alternative to the microphone-based method. (note)

  1. Nonlinear wave beams in a piezo semiconducting layer

    International Nuclear Information System (INIS)

    Bagdoev, A.G.; Shekoyan, A.V.; Danoyan, Z.N.

    1997-01-01

    The propagation of quasi-monochromatic nonlinear wave in a piezo semiconducting layer taking into account electron-concentration nonlinearity is considered. For such medium the evolution equations for incoming and reflected waves are derived. Nonlinear Schroedinger equations and solutions for narrow beams are obtained. It is shown that symmetry of incoming and reflected waves does not take place. The focusing of beams is investigated.18 refs

  2. Characterization of a next-generation piezo bimorph X-ray mirror for synchrotron beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Alcock, Simon G., E-mail: simon.alcock@diamond.ac.uk; Nistea, Ioana; Sutter, John P.; Sawhney, Kawal [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Fermé, Jean-Jacques; Thellièr, Christophe; Peverini, Luca [Thales-SESO, 305 rue Louis Armand, Pôle d’Activités d’Aix les Milles, Aix-en-Provence (France)

    2015-01-01

    A next-generation bimorph mirror with piezos bonded to the side faces of a monolithic substrate was created. When replacing a first-generation bimorph mirror suffering from the junction effect, the new type of mirror significantly improved the size and shape of the reflected synchrotron X-ray beam. No evidence of the junction effect was observed even after eight months of continuous beamline usage. Piezo bimorph mirrors are versatile active optics used on many synchrotron beamlines. However, many bimorphs suffer from the ‘junction effect’: a periodic deformation of the optical surface which causes major aberrations to the reflected X-ray beam. This effect is linked to the construction of such mirrors, where piezo ceramics are glued directly below the thin optical substrate. In order to address this problem, a next-generation bimorph with piezos bonded to the side faces of a monolithic substrate was developed at Thales-SESO and optimized at Diamond Light Source. Using metrology feedback from the Diamond-NOM, the optical slope error was reduced to ∼0.5 µrad r.m.s. for a range of ellipses. To maximize usability, a novel holder was built to accommodate the substrate in any orientation. When replacing a first-generation bimorph on a synchrotron beamline, the new mirror significantly improved the size and shape of the reflected X-ray beam. Most importantly, there was no evidence of the junction effect even after eight months of continuous beamline usage. It is hoped that this new design will reinvigorate the use of active bimorph optics at synchrotron and free-electron laser facilities to manipulate and correct X-ray wavefronts.

  3. Characterization of a next-generation piezo bimorph X-ray mirror for synchrotron beamlines

    International Nuclear Information System (INIS)

    Alcock, Simon G.; Nistea, Ioana; Sutter, John P.; Sawhney, Kawal; Fermé, Jean-Jacques; Thellièr, Christophe; Peverini, Luca

    2015-01-01

    A next-generation bimorph mirror with piezos bonded to the side faces of a monolithic substrate was created. When replacing a first-generation bimorph mirror suffering from the junction effect, the new type of mirror significantly improved the size and shape of the reflected synchrotron X-ray beam. No evidence of the junction effect was observed even after eight months of continuous beamline usage. Piezo bimorph mirrors are versatile active optics used on many synchrotron beamlines. However, many bimorphs suffer from the ‘junction effect’: a periodic deformation of the optical surface which causes major aberrations to the reflected X-ray beam. This effect is linked to the construction of such mirrors, where piezo ceramics are glued directly below the thin optical substrate. In order to address this problem, a next-generation bimorph with piezos bonded to the side faces of a monolithic substrate was developed at Thales-SESO and optimized at Diamond Light Source. Using metrology feedback from the Diamond-NOM, the optical slope error was reduced to ∼0.5 µrad r.m.s. for a range of ellipses. To maximize usability, a novel holder was built to accommodate the substrate in any orientation. When replacing a first-generation bimorph on a synchrotron beamline, the new mirror significantly improved the size and shape of the reflected X-ray beam. Most importantly, there was no evidence of the junction effect even after eight months of continuous beamline usage. It is hoped that this new design will reinvigorate the use of active bimorph optics at synchrotron and free-electron laser facilities to manipulate and correct X-ray wavefronts

  4. Clinical efficiency of Piezo-ICSI using micropipettes with a wall thickness of 0.625 μm.

    Science.gov (United States)

    Hiraoka, Kenichiro; Kitamura, Seiji

    2015-12-01

    The purposes of the present study are to assess the clinical efficiency of Piezo-intracytoplasmic sperm injection (ICSI) and to improve the Piezo-ICSI method for human oocytes. We examined three ICSI methods to determine their clinical efficiency by comparing the survival, fertilization, good-quality day-3 embryo, pregnancy, and live birth rates. The three ICSI methods tested were conventional ICSI (CI) (using beveled spiked micropipettes with a wall thickness of 1 μm), conventional Piezo-ICSI (CPI) (using flat-tipped micropipettes with a wall thickness of 0.925 μm), and improved Piezo-ICSI (IPI) (using flat-tipped micropipettes with a wall thickness of 0.625 μm). We collectively investigated 2020 mature oocytes retrieved from 437 patients between October 2010 and January 2014. The survival rates after CI, CPI, and IPI were 90, 95, and 99 %, respectively. The fertilization rates after CI, CPI, and IPI were 68, 75, and 89 %, respectively. The good-quality day-3 embryo rates after CI, CPI, and IPI were 37, 43, and 55 %, respectively. The pregnancy rates after the transfer of good-quality day-3 embryo of CI, CPI, and IPI were 19, 21, and 31 %, respectively. The live birth rates of CI, CPI, and IPI were 15, 16, and 25 %, respectively. Significantly higher survival, fertilization, good-quality day-3 embryo, pregnancy, and live birth rates were obtained using IPI. When comparing the IPI to the CI and CPI, the results revealed that the Piezo-ICSI using flat-tipped micropipettes with a wall thickness of 0.625 μm significantly improves survival, fertilization, good-quality day-3 embryo, pregnancy, and live birth rates.

  5. The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt

    Science.gov (United States)

    Hamdani, Syed Talha Ali; Fernando, Anura

    2015-01-01

    Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the event of an accident. In the current research a prototype safety belt is developed, which is used to acquire respiratory and heart signals, under laboratory conditions. The current safety belt is constructed using a copper ink based nonwoven material, which works based on the piezo-resistive effect due to the pressure exerted on the sensor as a result of expansion of the thorax/abdomen area of the body for respiration and due to the principle of ballistocardiography (BCG) in heart signal sensing. In this research, the development of a theoretical model to qualitatively describe the piezo-resistive material is also presented in order to predict the relative change in the resistance of the piezo-resistive material due to the pressure applied. PMID:25831088

  6. The application of a piezo-resistive cardiorespiratory sensor system in an automobile safety belt.

    Science.gov (United States)

    Hamdani, Syed Talha Ali; Fernando, Anura

    2015-03-30

    Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the event of an accident. In the current research a prototype safety belt is developed, which is used to acquire respiratory and heart signals, under laboratory conditions. The current safety belt is constructed using a copper ink based nonwoven material, which works based on the piezo-resistive effect due to the pressure exerted on the sensor as a result of expansion of the thorax/abdomen area of the body for respiration and due to the principle of ballistocardiography (BCG) in heart signal sensing. In this research, the development of a theoretical model to qualitatively describe the piezo-resistive material is also presented in order to predict the relative change in the resistance of the piezo-resistive material due to the pressure applied.

  7. The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt

    Directory of Open Access Journals (Sweden)

    Syed Talha Ali Hamdani

    2015-03-01

    Full Text Available Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the event of an accident. In the current research a prototype safety belt is developed, which is used to acquire respiratory and heart signals, under laboratory conditions. The current safety belt is constructed using a copper ink based nonwoven material, which works based on the piezo-resistive effect due to the pressure exerted on the sensor as a result of expansion of the thorax/abdomen area of the body for respiration and due to the principle of ballistocardiography (BCG in heart signal sensing. In this research, the development of a theoretical model to qualitatively describe the piezo-resistive material is also presented in order to predict the relative change in the resistance of the piezo-resistive material due to the pressure applied.

  8. Robust independent modal space control of a coupled nano-positioning piezo-stage

    Science.gov (United States)

    Zhu, Wei; Yang, Fufeng; Rui, Xiaoting

    2018-06-01

    In order to accurately control a coupled 3-DOF nano-positioning piezo-stage, this paper designs a hybrid controller. In this controller, a hysteresis observer based on a Bouc-Wen model is established to compensate the hysteresis nonlinearity of the piezoelectric actuator first. Compared to hysteresis compensations using Preisach model and Prandt-Ishlinskii model, the compensation method using the hysteresis observer is computationally lighter. Then, based on the proposed dynamics model, by constructing the modal filter, a robust H∞ independent modal space controller is designed and utilized to decouple the piezo-stage and deal with the unmodeled dynamics, disturbance, and hysteresis compensation error. The effectiveness of the proposed controller is demonstrated experimentally. The experimental results show that the proposed controller can significantly achieve the high-precision positioning.

  9. On compressible and piezo-viscous flow in thin porous media.

    Science.gov (United States)

    Pérez-Ràfols, F; Wall, P; Almqvist, A

    2018-01-01

    In this paper, we study flow through thin porous media as in, e.g. seals or fractures. It is often useful to know the permeability of such systems. In the context of incompressible and iso-viscous fluids, the permeability is the constant of proportionality relating the total flow through the media to the pressure drop. In this work, we show that it is also relevant to define a constant permeability when compressible and/or piezo-viscous fluids are considered. More precisely, we show that the corresponding nonlinear equation describing the flow of any compressible and piezo-viscous fluid can be transformed into a single linear equation. Indeed, this linear equation is the same as the one describing the flow of an incompressible and iso-viscous fluid. By this transformation, the total flow can be expressed as the product of the permeability and a nonlinear function of pressure, which represents a generalized pressure drop.

  10. Tuning Light Emission of a Pressure-Sensitive Silicon/ZnO Nanowires Heterostructure Matrix through Piezo-phototronic Effects.

    Science.gov (United States)

    Chen, Mengxiao; Pan, Caofeng; Zhang, Taiping; Li, Xiaoyi; Liang, Renrong; Wang, Zhong Lin

    2016-06-28

    Based on white light emission at silicon (Si)/ZnO hetrerojunction, a pressure-sensitive Si/ZnO nanowires heterostructure matrix light emitting diode (LED) array is developed. The light emission intensity of a single heterostructure LED is tuned by external strain: when the applied stress keeps increasing, the emission intensity first increases and then decreases with a maximum value at a compressive strain of 0.15-0.2%. This result is attributed to the piezo-phototronic effect, which can efficiently modulate the LED emission intensity by utilizing the strain-induced piezo-polarization charges. It could tune the energy band diagrams at the junction area and regulate the optoelectronic processes such as charge carriers generation, separation, recombination, and transport. This study achieves tuning silicon based devices through piezo-phototronic effect.

  11. Highly sensitive piezo-resistive graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone composites with improved conductive network construction.

    Science.gov (United States)

    Zhao, Hang; Bai, Jinbo

    2015-05-13

    The constructions of internal conductive network are dependent on microstructures of conductive fillers, determining various electrical performances of composites. Here, we present the advanced graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone (GCHs/PDMS) composites with high piezo-resistive performance. GCH particles were synthesized by the catalyst chemical vapor deposition approach. The synthesized GCHs can be well dispersed in the matrix through the mechanical blending process. Due to the exfoliated GNP and aligned CNTs coupling structure, the flexible composite shows an ultralow percolation threshold (0.64 vol %) and high piezo-resistive sensitivity (gauge factor ∼ 10(3) and pressure sensitivity ∼ 0.6 kPa(-1)). Slight motions of finger can be detected and distinguished accurately using the composite film as a typical wearable sensor. These results indicate that designing the internal conductive network could be a reasonable strategy to improve the piezo-resistive performance of composites.

  12. Molecular Recognition of PTS-1 Cargo Proteins by Pex5p: Implications for Protein Mistargeting in Primary Hyperoxaluria

    Directory of Open Access Journals (Sweden)

    Noel Mesa-Torres

    2015-02-01

    Full Text Available Peroxisomal biogenesis and function critically depends on the import of cytosolic proteins carrying a PTS1 sequence into this organelle upon interaction with the peroxin Pex5p. Recent structural studies have provided important insights into the molecular recognition of cargo proteins by Pex5p. Peroxisomal import is a key feature in the pathogenesis of primary hyperoxaluria type 1 (PH1, where alanine:glyoxylate aminotransferase (AGT undergoes mitochondrial mistargeting in about a third of patients. Here, we study the molecular recognition of PTS1 cargo proteins by Pex5p using oligopeptides and AGT variants bearing different natural PTS1 sequences, and employing an array of biophysical, computational and cell biology techniques. Changes in affinity for Pex5p (spanning over 3–4 orders of magnitude reflect different thermodynamic signatures, but overall bury similar amounts of molecular surface. Structure/energetic analyses provide information on the contribution of ancillary regions and the conformational changes induced in Pex5p and the PTS1 cargo upon complex formation. Pex5p stability in vitro is enhanced upon cargo binding according to their binding affinities. Moreover, we provide evidence that the rational modulation of the AGT: Pex5p binding affinity might be useful tools to investigate mistargeting and misfolding in PH1 by pulling the folding equilibria towards the native and peroxisomal import competent state.

  13. Extremely stable piezo mechanisms for the New Gravitational Wave Observatory

    NARCIS (Netherlands)

    Pijnenburg, J.A.C.M.; Rijnveld, N.; Hogenhuis, H.

    2012-01-01

    Detection and observation of gravitational waves requires extreme stability in the frequency range 3e-5 Hz to 1 Hz. NGO/LISA will attain this by creating a giant interferometer in space, based on free floating proof masses in three spacecrafts. To operate NGO/LISA, the following piezo mechanisms are

  14. Characterization of a next-generation piezo bimorph X-ray mirror for synchrotron beamlines.

    Science.gov (United States)

    Alcock, Simon G; Nistea, Ioana; Sutter, John P; Sawhney, Kawal; Fermé, Jean Jacques; Thellièr, Christophe; Peverini, Luca

    2015-01-01

    Piezo bimorph mirrors are versatile active optics used on many synchrotron beamlines. However, many bimorphs suffer from the `junction effect': a periodic deformation of the optical surface which causes major aberrations to the reflected X-ray beam. This effect is linked to the construction of such mirrors, where piezo ceramics are glued directly below the thin optical substrate. In order to address this problem, a next-generation bimorph with piezos bonded to the side faces of a monolithic substrate was developed at Thales-SESO and optimized at Diamond Light Source. Using metrology feedback from the Diamond-NOM, the optical slope error was reduced to ∼ 0.5 µrad r.m.s. for a range of ellipses. To maximize usability, a novel holder was built to accommodate the substrate in any orientation. When replacing a first-generation bimorph on a synchrotron beamline, the new mirror significantly improved the size and shape of the reflected X-ray beam. Most importantly, there was no evidence of the junction effect even after eight months of continuous beamline usage. It is hoped that this new design will reinvigorate the use of active bimorph optics at synchrotron and free-electron laser facilities to manipulate and correct X-ray wavefronts.

  15. Development of Pneumatic Transfer Irradiation Facility (PTS no.3) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-04-15

    A pneumatic transfer system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide. The pneumatic transfer irradiation system (PTS no.3) involving a manual system and an semi-automatic system were reconstructed with new designs of a functional improvement at the HANARO research reactor and NAA laboratory of RI building in 2006. In this technical report, the design, operation and control of these system (PTS no.3) was described. Also the experimental results and the characteristic parameters measured from a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  16. Development of Pneumatic Transfer Irradiation Facility (PTS no.1) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-03-15

    A pneumatic transfer system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide and a delayed neutron counting system. The pneumatic transfer system (PTS no.1) involving a manual system and an semiautomatic system were reconstructed with new designs of a functional improvement at the HANARO research reactor in 2006. In this technical report, the conception, design, operation and control of these system (PTS no.1) was described. Also the experimental results and the characteristic parameters measured by a mock-up test, a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  17. Design and development of fast pneumatic transfer system (PTS) for instrumental neutron activation analysis at Jordan research reactor

    International Nuclear Information System (INIS)

    Chung, Yongsam; Kim, Sunha; Moon, Jonghwa; Choi, Jinbok; Lee, Jongmin; Ryu, Jungsu

    2013-01-01

    A pneumatic transfer system (PTS) is one of the important equipment used for an neutron irradiation of a target material for an instrumental neutron activation analysis (INAA) in a research reactor. In particular, a rapid pneumatic transportation of irradiation capsule is essential for an accurate measurement of a short half-life nuclide. Three types of PTS for NAA facility at the Jordan Research and Training Reactor (JRTR) were newly developed for a functional improvement involving a manual and an automatic system which is equipped with programmable logic controller, software, and 13 devices to facilitate optimal operation of the system. In this paper, the designs and construction of these PTS, the operation and control of the system are described. In addition, a functional and operational test of the system were carried out as one of the basic requirement and characteristic parameters, and the results were reported to provide a user information as well as for the management and safety of the reactor

  18. Lateral nanowire/nanobelt based nanogenerators, piezotronics and piezo-phototronics

    KAUST Repository

    Wang, Zhong Lin

    2010-11-01

    Relying on the piezopotential created in ZnO under straining, nanogenerators, piezotronics and piezo-phototronics developed based on laterally bonded nanowires on a polymer substrate have been reviewed. The principle of the nanogenerator is a transient flow of electrons in external load as driven by the piezopotential created by dynamic straining. By integrating the contribution made by millions of nanowires, the output voltage has been raised to 1.2 V. Consequently, self-powered nanodevices have been demonstrated. This is an important platform technology for the future sensor network and the internet of things. Alternatively, the piezopotential can act as a gate voltage that can tune/gate the transport process of the charge carriers in the nanowire, which is a gate-electrode free field effect transistor (FET). The device fabricated based on this principle is called the piezotronic device. Piezo-phototronic effect is about the tuning and controlling of electro-optical processes by strain induced piezopotential. The piezotronic, piezophotonic and pieozo-phototronic devices are focused on low frequency applications in areas involving mechanical actions, such as MEMS/NEMS, nanorobotics, sensors, actuators and triggers. © 2010 Elsevier B.V. All rights reserved.

  19. Installation and evaluation of weigh-in-motion utilizing quartz-piezo sensor technology.

    Science.gov (United States)

    2016-06-28

    The objective of the research study was: to install a quartz-piezo based WIM system, and to : determine sensor survivability, accuracy and reliability under actual traffic conditions in : Connecticuts environment. If the systems prove dependable a...

  20. Portable bench tester for piezo weigh-in-motion equipment : executive summary report.

    Science.gov (United States)

    2006-06-01

    The Ohio Department of Transportation's (ODOT) piezo weigh-in-motion (WIM) equipment must be tested for initial working operation and to insure continued correct operation. Currently, the only available method to verify the vehicle classification par...

  1. Simple, low-noise piezo driver with feed-forward for broad tuning of external cavity diode lasers.

    Science.gov (United States)

    Doret, S Charles

    2018-02-01

    We present an inexpensive, low-noise (piezo driver suitable for frequency tuning of external-cavity diode lasers. This simple driver improves upon many commercially available drivers by incorporating circuitry to produce a "feed-forward" signal appropriate for making simultaneous adjustments to the piezo voltage and laser current, enabling dramatic improvements in a mode-hop-free laser frequency tuning range. We present the theory behind our driver's operation, characterize its output noise, and demonstrate its use in absorption spectroscopy on the rubidium D 1 line.

  2. SISTEM PENDUKUNG KEPUTUSAN PEMILIHAN PTS DI LHOKSEUMAWE MENGGUNAKAN METODE FUZZY AHP BERBASIS WEB

    Directory of Open Access Journals (Sweden)

    - Nurdin

    2015-07-01

    Full Text Available Sistem Pendukung Keputusan pemilihan PTS ini bertujuan untuk memberikan dukungan pengambilan keputusan untuk pemilihan sebuah PTS di Lhokseumawe. Pada sistem ini terdapat 11 alternatif perguruan tinggi swasta dan ada 6 kriteria yang digunakan oleh sistem. Sistem ini menggunakan metode fuzzy untuk kriteriayang bobot nilainya tidak tetap, kriteria tersebut diantaranya jumlah lulusan, Jarak dengan kota, Biaya pendidikan, jumlah dosen dan pendidikan dosen serta menggunakan metode Analytic Hierarchy Process (AHP  yaitu untuk perangkingan Perguruan Tinggi yang dipilih oleh user. Pemberian nilai fuzzy berlaku untuk setiap kriteria yang ada. Pada sistem ini juga terdapat 2 proses yakni proses pemilihan perguruan tinggi swasta dan proses membandingkan tingkat kepentingan antar kriteria. Perhitungan fuzzy pada sistem ini tidak dilakukan di dalam sistem melainkan di input oleh admin sistem yang telah dicari terlebih dahulu nilai fuzzy kriteria untuk tiap alternatif yang ada. Hasil dari proses fuzzy dan AHP dalam aplikasi ini akan menghasilkan perangkingan untuk alternatif yang dipilih oleh user.Kata kunci : Fuzzy, AHP, SPK, Pemilihan

  3. FO hydrophone with hydrostatic pressure compensation: comparative experiment with a conventional piezo hydrophone

    NARCIS (Netherlands)

    Cheng, L.K.; Bruijn, D. de

    1998-01-01

    This paper presents the performance of a TPD FO hydrophone with hydrostatic pressure compensation. In particularly a comparison with a conventional piezo hydrophone system is discussed. ©2003 Copyright SPIE

  4. Using piezo-electric material to simulate a vibration environment

    Science.gov (United States)

    Jepsen, Richard A.; Davie, Neil T.; Vangoethem, Douglas J.; Romero, Edward F.

    2010-12-14

    A target object can be vibrated using actuation that exploits the piezo-electric ("PE") property. Under combined conditions of vibration and centrifugal acceleration, a centrifugal load of the target object on PE vibration actuators can be reduced by using a counterweight that offsets the centrifugal loading. Target objects are also subjected to combinations of: spin, vibration, and acceleration; spin and vibration; and spin and acceleration.

  5. Does Maternal Parenting Stress Mediate the Association between Postpartum PTS Symptoms and Children's Internalizing and Externalizing Problems? A Longitudinal Perspective

    Science.gov (United States)

    Di Blasio, Paola; Camisasca, Elena; Miragoli, Sarah; Ionio, Chiara; Milani, Luca

    2017-01-01

    Background: The research carried out in the last years outlined that childbirth could be considered as a sufficient stressor for the insurgence of posttraumatic stress (PTS) symptoms with important consequences for the child care. Objectives: In a longitudinal perspective, this study focused on PTS symptoms after childbirth to understand their…

  6. Experimental validation of plant peroxisomal targeting prediction algorithms by systematic comparison of in vivo import efficiency and in vitro PTS1 binding affinity.

    Science.gov (United States)

    Skoulding, Nicola S; Chowdhary, Gopal; Deus, Mara J; Baker, Alison; Reumann, Sigrun; Warriner, Stuart L

    2015-03-13

    Most peroxisomal matrix proteins possess a C-terminal targeting signal type 1 (PTS1). Accurate prediction of functional PTS1 sequences and their relative strength by computational methods is essential for determination of peroxisomal proteomes in silico but has proved challenging due to high levels of sequence variability of non-canonical targeting signals, particularly in higher plants, and low levels of availability of experimentally validated non-canonical examples. In this study, in silico predictions were compared with in vivo targeting analyses and in vitro thermodynamic binding of mutated variants within the context of one model targeting sequence. There was broad agreement between the methods for entire PTS1 domains and position-specific single amino acid residues, including residues upstream of the PTS1 tripeptide. The hierarchy Leu>Met>Ile>Val at the C-terminal position was determined for all methods but both experimental approaches suggest that Tyr is underweighted in the prediction algorithm due to the absence of this residue in the positive training dataset. A combination of methods better defines the score range that discriminates a functional PTS1. In vitro binding to the PEX5 receptor could discriminate among strong targeting signals while in vivo targeting assays were more sensitive, allowing detection of weak functional import signals that were below the limit of detection in the binding assay. Together, the data provide a comprehensive assessment of the factors driving PTS1 efficacy and provide a framework for the more quantitative assessment of the protein import pathway in higher plants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Piezo-earpiece for micro-power generation from ear canal dynamic motion

    International Nuclear Information System (INIS)

    Delnavaz, Aidin; Voix, Jérémie

    2013-01-01

    This paper focuses on improving the past performance of ear canal energy harvesting by developing a piezo-earpiece prototype and a multiphysics finite element method to integrate more complex and effective piezoelectric structures. The proposed handmade piezo-earpiece prototype is a custom-moulded soft earpiece wrapped in a layer of flexible polyvinylidene fluoride. A finite element model is developed in order to estimate the energy harvesting capability of the piezoelectric layer. A prototype of the energy harvester is fabricated and tested. The experimental results show that the proposed device is able to generate 44 μJ of energy corresponding to an average value of 70 μW per jaw opening and closing cycle. Simulation of energy harvesting based on the finite element method is validated by the experimental results, thus confirming it as a versatile tool to model, optimize and evaluate the performance of other types of flexible piezoelectric structures for in-ear energy harvesting applications. (paper)

  8. Structural and thermal analysis of a solid-cooled, low energy booster, radio-frequency-cavity tuner at the Superconducting Super Collider

    International Nuclear Information System (INIS)

    Ranganathan, R.; Propp, A.; Dao, B.; Campbell, B.

    1993-04-01

    A three-dimensional heat conduction and structural model was developed to analyze and optimize the design of a solid-cooled low energy booster (LEB) radio-frequency (RF) cavity tuner concept. Consideration was given to three cooling options: (1) using beryllium oxide (BeO) disks, (2) using aluminum nitride (A1N) disks and (3) using neither BeO nor AlN disks. The results indicate that solid cooling is feasible from thermal and structural viewpoints if a minimum of two BeO disks or four AlN disks are used

  9. Structural and thermal analysis of a solid-cooled, low energy booster, radio-frequency-cavity tuner at the Superconducting Super Collider

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, R.; Propp, A.; Dao, B.; Campbell, B.

    1993-04-01

    A three-dimensional heat conduction and structural model was developed to analyze and optimize the design of a solid-cooled low energy booster (LEB) radio-frequency (RF) cavity tuner concept. Consideration was given to three cooling options: (1) using beryllium oxide (BeO) disks, (2) using aluminum nitride (A1N) disks and (3) using neither BeO nor AlN disks. The results indicate that solid cooling is feasible from thermal and structural viewpoints if a minimum of two BeO disks or four AlN disks are used.

  10. Cryomodule tests of the TESLA-like superconducting cavity in KEK-STF

    International Nuclear Information System (INIS)

    Kako, Eiji; Sato, Masato; Shishido, Toshio; Noguchi, Shuichi; Hatori, Hirofumi; Hayano, Hitoshi; Yamamoto, Yasuchika; Watanabe, Ken

    2008-01-01

    Construction of STF (Superconducting RF Test Facility) is being carried out at KEK. The STF-Baseline superconducting cavity system, which includes four TESLA-like 9-cell cavities, input couplers and frequency tuners, has been developed for the future ILC project. A 6-m cryomodule including one of four TESLA-like cavities was assembled, and the cryomodule was installed in the tunnel for the initial test, called the STF Phase-0.5. The first cool-down of the cryomodule and high power tests of the cavity had been carried out at 2 K from October to November, 2007. The maximum accelerating gradient (Eacc, max) of 19.3 MV/m was achieved in a specific pulse width of 1.5 msec and a repetition rate of 5 Hz, (23.4 MV/m in a shorter pulse width of 0.6 msec). Compensation of Lorentz force detuning at 18 MV/m was successfully demonstrated by using a piezo tuner. The second cryomodule test for four cavities, called the STF Phase-1.0, is scheduled in July, 2008. (author)

  11. Influence of the Lubricant Thermo-Piezo-Viscous Property on Hydrostatic Bearings in Oil Hydraulics

    DEFF Research Database (Denmark)

    Johansen, Per; Roemer, Daniel Beck; Andersen, Torben O.

    2016-01-01

    adds to the discrepancy of such simple design approach. In this paper the hydrostatic pressure force calculation is reviewed in terms of thermohydrodynamic (THD) lubrication theory, and simple analytical approximations of the hydrostatic pressure force, incorporating the piezo-viscous and thermo...... of these analytical approximations are explored in order to clarify the limits of application. In conclusion, it is found that the spatial gradient of the thermal field on the bearing surface is the significant factor in the thermo-viscous effect on the hydrostatic pressure profile, which leads to the conclusion...... that design engineers need to understand the thermodynamics of hydrostatic bearings, when using the conventional simple analytical approach, neglecting thermo-piezo-viscosity, in hydrostatic pressure force calculations....

  12. Optimizing performance of silicon-based p-n junction photodetectors by the piezo-phototronic effect.

    Science.gov (United States)

    Wang, Zhaona; Yu, Ruomeng; Wen, Xiaonan; Liu, Ying; Pan, Caofeng; Wu, Wenzhuo; Wang, Zhong Lin

    2014-12-23

    Silicon-based p-n junction photodetectors (PDs) play an essential role in optoelectronic applications for photosensing due to their outstanding compatibility with well-developed integrated circuit technology. The piezo-phototronic effect, a three-way coupling effect among semiconductor properties, piezoelectric polarizations, and photon excitation, has been demonstrated as an effective approach to tune/modulate the generation, separation, and recombination of photogenerated electron-hole pairs during optoelectronic processes in piezoelectric-semiconductor materials. Here, we utilize the strain-induced piezo-polarization charges in a piezoelectric n-ZnO layer to modulate the optoelectronic process initiated in a p-Si layer and thus optimize the performances of p-Si/ZnO NWs hybridized photodetectors for visible sensing via tuning the transport property of charge carriers across the Si/ZnO heterojunction interface. The maximum photoresponsivity R of 7.1 A/W and fastest rising time of 101 ms were obtained from these PDs when applying an external compressive strain of -0.10‰ on the ZnO NWs, corresponding to relative enhancement of 177% in R and shortening to 87% in response time, respectively. These results indicate a promising method to enhance/optimize the performances of non-piezoelectric semiconductor material (e.g., Si) based optoelectronic devices by the piezo-phototronic effect.

  13. ウサギICSI (Intracytoplasmic Sperm Injection)におけるPiezo-ICSIの有用性の検討

    OpenAIRE

    鈴木, 智草; 細井, 美彦; 加藤, 博己; 松本, 和也; 佐伯, 和弘; 入谷, 明

    2000-01-01

    Piezo-ICSIは、マウス、ヒト、ウシにおいて、Conventional ICSIよりも有用であることが報告されている。Piezo-ICSIはConventional ICSIと比較して、透明帯や卵細胞膜へのダメージが少ないといわれている。本実験では、ウサギ卵子を用いて、Conventional ICSI (Con) と Piezo-ICSI (Piezo)を行い、in vitro とin vivoにおいての発生率を比較、検討した。Conおける生存率、卵割率、胚盤胞期胚への発生率はそれぞれ65.1%、83.5%、16.4%であった。対して、Piezoでは、69.6%、82.8%、34.3%であった。生存率、受精率に有為な差は見られなかったが、胚盤胞期胚への発生率は、5%水準で有為差が見られた。また、同期化処理をした雌ウサギへの卵管移植の結果、Con 1% (1/70)、Piezo6% (4/70)の割合で産子が得られた。以上のことより、ウサギ卵子に対してのPiezo-ICSIは Conventional ICSIよりも有用であることが示唆された。 (英文) It report...

  14. Development of Pneumatic Transfer Irradiation Facility (PTS no.2) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-03-15

    A pneumatic transfer irradiation system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide and a delayed neutron counting system. The pneumatic transfer irradiation system (PTS no.2) involving a manual system and an automatic system for delayed neutron activation analysis (DNAA) were reconstructed with new designs of a functional improvement at the HANARO research reactor in 2006. In this technical report, the conception, design, operation and control of PTS no.2 was described. Also the experimental results and the characteristic parameters measured by a mock-up test, a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, automatic operation control by personal computer, delayed neutron counting system, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  15. A wideband CMOS inductorless low noise amplifier employing noise cancellation for digital TV tuner applications

    International Nuclear Information System (INIS)

    Zhang Jihong; Bai Xuefei; Huang Lu

    2013-01-01

    A wideband inductorless low noise amplifier for digital TV tuner applications is presented. The proposed LNA scheme uses a composite NMOS/PMOS cross-coupled transistor pair to provide partial cancellation of noise generated by the input transistors. The chip is implemented in SMIC 0.18 μm CMOS technology. Measurement shows that the proposed LNA achieves 12.2–15.2 dB voltage gain from 300 to 900 MHz, the noise figure is below 3.1 dB and has a minimum value of 2.3 dB, and the best input-referred 1-dB compression point (IP1dB) is − 17 dBm at 900 MHz. The core consumes 7 mA current with a supply voltage of 1.8 V and occupies an area of 0.5 × 0.35 mm 2 . (semiconductor integrated circuits)

  16. Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal

    International Nuclear Information System (INIS)

    Ibraheem, Zeyid T.; Rahman, Md. Mijanur; Yaakob, S. N.; Razalli, Mohammad Shahrazel; Kadhim, Rasim A.

    2015-01-01

    Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed an investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction

  17. Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal

    Energy Technology Data Exchange (ETDEWEB)

    Ibraheem, Zeyid T.; Rahman, Md. Mijanur; Yaakob, S. N.; Razalli, Mohammad Shahrazel; Kadhim, Rasim A. [School of Computer and Communication Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis (Malaysia)

    2015-05-15

    Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed an investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction.

  18. Analysis of double stub tuner control stability in a phased array antenna with strong cross-coupling

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, G.M., E-mail: wallaceg@mit.edu [MIT Plasma Science and Fusion Center, Cambridge, MA 02139 (United States); Hillairet, J. [CEA-IRFM, Saint-Paul-lez-Durance (France); Koert, P.; Lin, Y.; Shiraiwa, S.; Wukitch, S.J. [MIT Plasma Science and Fusion Center, Cambridge, MA 02139 (United States)

    2014-11-15

    Highlights: • A novel method for reducing reflection coefficients for LHCD launchers is proposed and evaluated. • Numerical models of antenna behavior with stub tuning are analyzed. • The system is found to be stable under most realistic operating conditions. - Abstract: Active stub tuning with a fast ferrite tuner (FFT) has greatly increased the effectiveness of fusion ion cyclotron range of frequency (ICRF) systems (50–100 MHz) by allowing for the antenna system to respond dynamically to changes in the plasma load impedance such as during the L–H transition or edge localized modes (ELMs). A high power waveguide double-stub tuner is under development for use with the Alcator C-Mod lower hybrid current drive (LHCD) system at 4.6 GHz. The amplitude and relative phase shift between adjacent columns of an LHCD antenna are critical for control of the launched n{sub ||} spectrum. Adding a double-stub tuning network will perturb the phase and amplitude of the forward wave particularly if the unmatched reflection coefficient is high. This effect can be compensated by adjusting the phase of the low power microwave drive for each klystron amplifier. Cross-coupling of the reflected power between columns of the launcher must also be considered. The problem is simulated by cascading a scattering matrix for the plasma provided by a linear coupling model with the measured launcher scattering matrix and that of the FFTs. The solution is advanced in an iterative manner similar to the time-dependent behavior of the real system. System performance is presented under a range of edge density conditions from under-dense to over-dense and a range of launched n{sub ||}. Simulations predict power reflection coefficients (Γ{sup 2}) of less than 1% with no contamination of the n{sub ||} spectrum. Instability of the FFT tuning network can be problematic for certain plasma conditions and relative phasings, but reducing the control gain of the FFT network stabilizes the system.

  19. CdS nanorods/organic hybrid LED array and the piezo-phototronic effect of the device for pressure mapping.

    Science.gov (United States)

    Bao, Rongrong; Wang, Chunfeng; Dong, Lin; Shen, Changyu; Zhao, Kun; Pan, Caofeng

    2016-04-21

    As widely applied in light-emitting diodes and optical devices, CdS has attracted the attention of many researchers due to its nonlinear properties and piezo-electronic effect. Here, we demonstrate a LED array composed of PSS and CdS nanorods and research the piezo-photonic effect of the array device. The emission intensity of the device depends on the electron-hole recombination at the interface of the p-n junction which can be adjusted using the piezo-phototronic effect and can be used to map the pressure applied on the surface of the device with spatial resolution as high as 1.5 μm. A flexible LED device array has been prepared using a CdS nanorod array on a Au/Cr/kapton substrate. This device may be used in the field of strain mapping using its high pressure spatial-resolution and flexibility.

  20. Portable bench tester for piezo weigh-in-motion equipment : final report, June 2006.

    Science.gov (United States)

    2006-06-01

    The Ohio Department of Transportation's (ODOT) piezo weigh-in-motion (WIM) equipment must be tested for initial working operation and to insure continued correct operation. Currently, the only available method to verify the vehicle classification par...

  1. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Ho-Lung Hung

    2008-08-01

    Full Text Available A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  2. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Lee Shu-Hong

    2008-01-01

    Full Text Available Abstract A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  3. Piezo-optical and electro-optical behaviour of nematic liquid crystals dispersed in a ferroelectric copolymer matrix

    International Nuclear Information System (INIS)

    Ganesan, Lakshmi Meena; Wirges, Werner; Gerhard, Reimund; Mellinger, Axel

    2010-01-01

    Polymer-dispersed liquid crystals (PDLCs) are composite materials that consist of micrometre-sized liquid-crystal (LC) droplets embedded in a polymer matrix. From ferroelectric poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) and a nematic LC, PDLC films containing 10 and 60 wt% LC were prepared, and their electro-optical and piezo-optical behaviour was investigated. The electric field that is generated by the application of mechanical stress leads to changes in the transmittance of the PDLC film through a combination of piezoelectric and electro-optical effects. Such a piezo-optical PDLC material may be useful, e.g., in sensing and visualization applications.

  4. Model-Based Control of an Aircraft Engine using an Optimal Tuner Approach

    Science.gov (United States)

    Connolly, Joseph W.; Chicatelli, Amy; Garg, Sanjay

    2012-01-01

    This paper covers the development of a model-based engine control (MBEC) method- ology applied to an aircraft turbofan engine. Here, a linear model extracted from the Commercial Modular Aero-Propulsion System Simulation 40,000 (CMAPSS40k) at a cruise operating point serves as the engine and the on-board model. The on-board model is up- dated using an optimal tuner Kalman Filter (OTKF) estimation routine, which enables the on-board model to self-tune to account for engine performance variations. The focus here is on developing a methodology for MBEC with direct control of estimated parameters of interest such as thrust and stall margins. MBEC provides the ability for a tighter control bound of thrust over the entire life cycle of the engine that is not achievable using traditional control feedback, which uses engine pressure ratio or fan speed. CMAPSS40k is capable of modeling realistic engine performance, allowing for a verification of the MBEC tighter thrust control. In addition, investigations of using the MBEC to provide a surge limit for the controller limit logic are presented that could provide benefits over a simple acceleration schedule that is currently used in engine control architectures.

  5. Tunable band gaps in acoustic metamaterials with periodic arrays of resonant shunted piezos

    International Nuclear Information System (INIS)

    Chen Sheng-Bing; Wen Ji-Hong; Wang Gang; Wen Xi-Sen

    2013-01-01

    Periodic arrays of resonant shunted piezoelectric patches are employed to control the wave propagation in a two-dimensional (2D) acoustic metamaterial. The performance is characterized by the finite element method. More importantly, we propose an approach to solving the conventional issue of the nonlinear eigenvalue problem, and give a convenient solution to the dispersion properties of 2D metamaterials with periodic arrays of resonant shunts in this article. Based on this modeling method, the dispersion relations of a 2D metamaterial with periodic arrays of resonant shunted piezos are calculated. The results show that the internal resonances of the shunting system split the dispersion curves, thereby forming a locally resonant band gap. However, unlike the conventional locally resonant gap, the vibrations in this locally resonant gap are unable to be completely localized in oscillators consisting of shunting inductors and piezo-patches

  6. Monolithic optofluidic mode coupler for broadband thermo- and piezo-optical characterization of liquids.

    Science.gov (United States)

    Pumpe, Sebastian; Chemnitz, Mario; Kobelke, Jens; Schmidt, Markus A

    2017-09-18

    We present a monolithic fiber device that enables investigation of the thermo- and piezo-optical properties of liquids using straightforward broadband transmission measurements. The device is a directional mode coupler consisting of a multi-mode liquid core and a single-mode glass core with pronounced coupling resonances whose wavelength strongly depend on the operation temperature. We demonstrated the functionality and flexibility of our device for carbon disulfide, extending the current knowledge of the thermo-optic coefficient by 200 nm at 20 °C and uniquely for high temperatures. Moreover, our device allows measuring the piezo-optic coefficient of carbon disulfide, confirming results first obtained by Röntgen in 1891. Finally, we applied our approach to obtain the dispersion of the thermo-optic coefficients of benzene and tetrachloroethylene between 450 and 800 nm, whereas no data was available for the latter so far.

  7. Omnidirectional piezo-optical ring sensor for enhanced guided wave structural health monitoring

    International Nuclear Information System (INIS)

    Giurgiutiu, Victor; Roman, Catalin; Lin, Bin; Frankforter, Erik

    2015-01-01

    This paper presents a novel method for the detection of ultrasonic waves from acoustic emission events using piezoelectric wafer ac3tive sensors (PWAS) and optical fiber Bragg grating (FBG) sensing combined with mechanical resonance amplification principles. The method is best suited for detecting the out-of-plane motion of the AE wave with preference for a certain frequency that can be adjusted by design. Several issues are discussed: (a) study the mode shapes of the sensors under different resonance frequencies in order to understand the behavior of the ring in a frequency band of interest; (b) comparison of analytical results and mode shapes with FEM predictions; (c) choice of the final piezo-optical ring sensor shape; (d) testing of the piezo-optical ring sensor prototype; (e) discussion of the ring-sensor test results in comparison with conventional results from PWAS and FBG sensors mounted directly on the test structure. The paper ends with summary, conclusions, and suggestions for further work. (paper)

  8. A PhD abstract presentation on Cluster Framework for Internet of People, Things and Services (IoPTS)

    DEFF Research Database (Denmark)

    Shinde, Gitanjali; Olesen, Henning

    2014-01-01

    The Internet of Things (IoT) is a revolutionary technology, where devices around us are capable of sensing, reacting, responding and working autonomously to provide services to the users /people, e.g. smart homes, enterprise, utilities and e-Health. In the IoT paradigm, every device will be conne......The Internet of Things (IoT) is a revolutionary technology, where devices around us are capable of sensing, reacting, responding and working autonomously to provide services to the users /people, e.g. smart homes, enterprise, utilities and e-Health. In the IoT paradigm, every device...... will be connected to the Internet to provide services to the user. Bringing this together makes it relevant to talk about the "Internet of People, Things and Services (IoPTS)."However, managing such a huge number of devices is a major challenge for IoPTS. In any given context, a number of devices will work together...... announce their services to those who need them. Users can access these services with the help of widely interconnected devices. To access the services user has to provide some personal data. In IoPTS services are large in numbers, and to protect the user data there is a need to ensure that these services...

  9. Miniaturized Low-Power Piezo Microvalve for NanoSat and CubeSat Propulsion, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In the Phase I effort, Busek developed a miniature precision piezo-actuated microvalve weighing 32g and occupying 4.5 cm^3. The valve demonstrated continuous flow...

  10. A 0.18 μm CMOS inductorless complementary-noise-canceling-LNA for TV tuner applications

    International Nuclear Information System (INIS)

    Yuan Haiquan; Lin Fujiang; Fu Zhongqian; Huang Lu

    2010-01-01

    This paper presents an inductorless complementary-noise-canceling LNA (CNCLNA) for TV tuners. The CNCLNA exploits single-to-differential topology, which consists of a common gate stage and a common source stage. The complementary topology can save power and improve the noise figure. Linearity is also enhanced by employing a multiple gated transistors technique. The chip is implemented in SMIC 0.18 μm CMOS technology. Measurement shows that the proposed CNCLNA achieves 13.5-16 dB voltage gain from 50 to 860 MHz, the noise figure is below 4.5 dB and has a minimum value of 2.9 dB, and the best P 1dB is -7.5 dBm at 860 MHz. The core consumes 6 mA current with a supply voltage of 1.8 V, while the core area is only 0.2 x 0.2 mm 2 . (semiconductor integrated circuits)

  11. Effect of MnO2, Bi2O3, and ZnO additions on the electrical properties of lead zirconate titanate piezo ceramics

    International Nuclear Information System (INIS)

    Klimov, V.V.; Selikova, N.I.; Bronnikov, A.N.

    2006-01-01

    The effect of manganese dioxide additions on the electrical properties of lead zirconate titanate (PZT) piezo ceramics has been investigated. The results demonstrate that, taken alone, manganese dioxide does not ensure the formation of hard PZT. The valence state of manganese in the piezo ceramics is shown to be 4+ if no other dopants are present and 3+ if manganese is introduced in combination with Bi and Zn. Microstructural examination indicates that the grain size of the singly doped ceramics is 5-15 μm, while that of the codoped ceramics is 1-3 μm. The polarization current curves of the piezo ceramics containing manganese, bismuth, and zinc oxides have extra maxima, which points to significant internal fields. The manganese is shown to reside at grain boundaries. The conclusion is made that it is the composition of Mn-containing intergranular phases, rather than the presence of manganese ions, that plays a key role in the formation of hard piezo ceramics [ru

  12. Determination of flow-rate characteristics and parameters of piezo pilot valves

    Directory of Open Access Journals (Sweden)

    Takosoglu Jakub

    2017-01-01

    Full Text Available Pneumatic directional valves are used in most industrial pneumatic systems. Most of them are two-stage valves controlled by a pilot valve. Pilot valves are often chosen randomly. Experimental studies in order to determine the flow-rate characteristics and parameters of pilot valves were not conducted. The paper presents experimental research of two piezo pilot valves.

  13. Simple and robust phase-locking of optical cavities with > 200 KHz servo-bandwidth using a piezo-actuated mirror mounted in soft materials.

    Science.gov (United States)

    Goldovsky, David; Jouravsky, Valery; Pe'er, Avi

    2016-12-12

    We present an approach to locking of optical cavities with piezoelectric actuated mirrors based on a simple and effective mechanical decoupling of the mirror and actuator from the surrounding mount. Using simple elastic materials (e.g. rubber or soft silicone gel pads) as mechanical dampers between the piezo-mirror compound and the surrounding mount, a firm and stable mounting of a relatively large mirror (8mm diameter) can be maintained that is isolated from external mechanical resonances, and is limited only by the internal piezo-mirror resonance of > 330 KHz. Our piezo lock showed positive servo gain up to 208 KHz, and a temporal response to a step interference within < 3 μs.

  14. Piezo channels and GsMTx4: Two milestones in our understanding of excitatory mechanosensitive channels and their role in pathology.

    Science.gov (United States)

    Suchyna, Thomas M

    2017-11-01

    Discovery of Piezo channels and the reporting of their sensitivity to the inhibitor GsMTx4 were important milestones in the study of non-selective cationic mechanosensitive channels (MSCs) in normal physiology and pathogenesis. GsMTx4 had been used for years to investigate the functional role of cationic MSCs, especially in muscle tissue, but with little understanding of its target or inhibitory mechanism. The sensitivity of Piezo channels to bilayer stress and its robust mechanosensitivity when expressed in heterologous systems were keys to determining GsMTx4's mechanism of action. However, questions remain regarding Piezo's role in muscle function due to the non-selective nature of GsMTx4 inhibition toward membrane mechanoenzymes and the implication of MCS channel types by genetic knockdown. Evidence supporting Piezo like activity, at least in the developmental stages of muscle, is presented. While the MSC targets of GsMTx4 in muscle pathology are unclear, its muscle protective effects are clearly demonstrated in two recent in situ studies on normal cardiomyocytes and dystrophic skeletal muscle. The muscle protective function may be due to the combined effect of GsMTx4's inhibitory action on cationic MSCs like Piezo and TRP, and its potentiation of repolarizing K + selective MSCs like K2P and SAKCa. Paradoxically, the potent in vitro action of GsMTx4 on many physiological functions seems to conflict with its lack of in situ side-effects on normal animal physiology. Future investigations into cytoskeletal control of sarcolemma mechanics and the suspected inclusion of MSCs in membrane micro/nano sized domains with distinct mechanical properties will aide our understanding of this dichotomy. Published by Elsevier Ltd.

  15. A hybrid peptide PTS that facilitates transmembrane delivery and its application for the rapid in vivo imaging via near-infrared fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Xuejiao eYan

    2016-03-01

    Full Text Available Background and purpose: Intravital imaging provides invaluable readouts for clinical diagnoses and therapies and shows great potential in the design of individualized drug dosage regimes. Ts is a mammalian free cell membrane-penetrating peptide. This study aimed to introduce a novel approach to the design of a cancer-selective peptide on the basis of a membrane-penetrating peptide and to explore its potential as a carrier of medical substances. Experimental approach: Ts was linked with a αvβ3-binding peptide P1c to create a hybrid referred to as PTS. The hybrid was labeled with an FITC or Cy5.5 as an imaging indicator to evaluate its in vitro and in vivo bioactivity. Key results: Hemolysis tests proved that in comparison with Ts, PTS caused similar or even less leakage of human erythrocytes at concentrations of up to 1 mmol/L. Flow cytometry assay and confocal microscopy demonstrated the following. 1 P1c alone could target and mostly halt at the cancer cell membrane. 2 Ts alone could not bind to the membrane sufficiently. 3 P1c greatly enhanced the binding affinity of PTS with MDA-MB-231 breast cancer cells that upregulated αvβ3. 4 Ts conferred PTS with the ability to traverse a cell membrane and thus facilitate the transmembrane delivery of imaging probes. In vivo near-infrared fluorescence (NIRF imaging demonstrated that the imaging probes were rapidly concentrated in a MDA-MB-231 tumor tissue within 1 h after intravenous injection. Conclusions and implications: PTS exhibited the capability of targeting specific tumors and greatly facilitating the transmembrane delivery of imaging probes.

  16. Symmetrical metallic and magnetic edge states of nanoribbon from semiconductive monolayer PtS2

    Science.gov (United States)

    Liu, Shan; Zhu, Heyu; Liu, Ziran; Zhou, Guanghui

    2018-03-01

    Transition metal dichalcogenides (TMD) MoS2 or graphene could be designed to metallic nanoribbons, which always have only one edge show metallic properties due to symmetric protection. In present work, a nanoribbon with two parallel metallic and magnetic edges was designed from a noble TMD PtS2 by employing first-principles calculations based on density functional theory (DFT). Edge energy, bonding charge density, band structure, density of states (DOS) and simulated scanning tunneling microscopy (STM) of four possible edge states of monolayer semiconductive PtS2 were systematically studied. Detailed calculations show that only Pt-terminated edge state among four edge states was relatively stable, metallic and magnetic. Those metallic and magnetic properties mainly contributed from 5d orbits of Pt atoms located at edges. What's more, two of those central symmetric edges coexist in one zigzag nanoribbon, which providing two atomic metallic wires thus may have promising application for the realization of quantum effects, such as Aharanov-Bohm effect and atomic power transmission lines in single nanoribbon.

  17. Largely Improved Near-Infrared Silicon-Photosensing by the Piezo-Phototronic Effect.

    Science.gov (United States)

    Dai, Yejing; Wang, Xingfu; Peng, Wenbo; Zou, Haiyang; Yu, Ruomeng; Ding, Yong; Wu, Changsheng; Wang, Zhong Lin

    2017-07-25

    Although silicon (Si) devices are the backbone of modern (opto-)electronics, infrared Si-photosensing suffers from low-efficiency due to its limitation in light-absorption. Here, we demonstrate a large improvement in the performance, equivalent to a 366-fold enhancement in photoresponsivity, of a Si-based near-infrared (NIR) photodetector (PD) by introducing the piezo-phototronic effect via a deposited CdS layer. By externally applying a -0.15‰ compressive strain to the heterojunction, carrier-dynamics modulation at the local junction can be induced by the piezoelectric polarization, and the photoresponsivity and detectivity of the PD exhibit an enhancement of two orders of magnitude, with the peak values up to 19.4 A/W and 1.8 × 10 12 cm Hz 1/2 /W, respectively. The obtained maximum responsivity is considerably larger than those of commercial Si and InGaAs PDs in the NIR waveband. Meanwhile, the rise time and fall time are reduced by 84.6% and 76.1% under the external compressive strain. This work provides a cost-effective approach to achieve high-performance NIR photosensing by the piezo-phototronic effect for high-integration Si-based optoelectronic systems.

  18. PTS assessment - The basis of life time evaluation at NPP Paks

    International Nuclear Information System (INIS)

    Elter, J.; Oszwald, F.; Ratkay, S.; Fekete, T.; Gillemot, F.; Marothy, L.

    1997-01-01

    Plant specific PTS analysis at NPP Paks was performed in the frame of the AGNES (Advanced General New Evaluation of Safety) project. NPP Paks belongs to the second generation of the WWER-440/213 NPP-s. To verify the safety during transient events and predict the lifetime of the RPV-s several transient cases have been analyzed. The paper summarizes: The general scheme elaborated for the assessment; the safety philosophy used; the applied and available codes and methods; the ongoing and planned developments. (author). 8 refs, 3 figs, 1 tab

  19. PTS assessment - The basis of life time evaluation at NPP Paks

    Energy Technology Data Exchange (ETDEWEB)

    Elter, J; Oszwald, F; Ratkay, S [NPP Paks (Hungary); Fekete, T; Gillemot, F; Marothy, L [Atomic Energy Research Inst., Budapest (Hungary)

    1997-09-01

    Plant specific PTS analysis at NPP Paks was performed in the frame of the AGNES (Advanced General New Evaluation of Safety) project. NPP Paks belongs to the second generation of the WWER-440/213 NPP-s. To verify the safety during transient events and predict the lifetime of the RPV-s several transient cases have been analyzed. The paper summarizes: The general scheme elaborated for the assessment; the safety philosophy used; the applied and available codes and methods; the ongoing and planned developments. (author). 8 refs, 3 figs, 1 tab.

  20. Class-D amplifier design and performance for driving a Piezo Actuator Drive servomotor

    DEFF Research Database (Denmark)

    Zsurzsan, Tiberiu-Gabriel; Zhang, Zhe; Andersen, Michael A. E.

    2016-01-01

    This paper investigates the behavior of piezoelectric stacks in a Piezoelectric Actuator Drive (PAD) motor, which shows non-linear equivalent impedance and has a dramatic impact on the overall system performance. Therefore, in this paper, the piezo stackt’s model is discussed and an improved large...

  1. A probabilistic approach to the evaluation of the PTS issue

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Selby, D.L.

    1991-01-01

    An integrated probabilistic approach for the evaluation of the pressurized-thermal-shock (PTS) issue was developed at the Oak Ridge National Laboratory (ORNL) at the request of the Nuclear Regulatory Commission (NRC). The purpose was to provide a method for identifying dominant plant design and operating features, evaluating possible remedial measures and the validity of the NRC PTS screening criteria, and to provide an additional tool for estimating vessel life expectancy. The approach was to be integrated in the sense that it would include the postulation of transients; estimates of their frequencies of occurrence; systems analyses to obtain the corresponding primary-system pressure, down-comer coolant temperature, and fluid-film heat-transfer coefficient adjacent to the vessel wall; and a probabilistic fracture-mechanics analysis, using the latter data as input. A summation of the products of frequency of transient and conditional probability of failure for all postulated transients provides an estimate of frequency of vessel failure. In the process of developing the integrated pressurized-thermal-shock (IPTS) methodology, three specific plant analyses were conducted. The results indicate that the NRC screening criteria may not be appropriate for all US pressurized water reactor (PWR) plants; that is, for some PWRs, the calculated mean frequency of vessel failure corresponding to the screening criteria may be greater than the maximum permissible value in Regulatory Guide 1.154. A recent view of the ORNL IPTS study, which was completed in 1985, indicates that there are a number of areas in which the methodology can and should be updated, but it is not clear whether the update will increase or decrease the calculated probabilities. 31 refs., 2 tabs

  2. Design issues of the piezo motor for the spacecraft reflector control system

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available Creation of large-size reflectors for spacecrafts is a topical issue for the space industry. The accuracy of the reflecting surface form and the structure weight are the main criteria for the reflector design. The accuracy of the reflecting surface form during a long-term operation is provided by adjustment when using piezoelectric motors in the reflector design. These motors have small weight-size parameters and can reach great torque values. The piezo motor is a distributed mechanical-acoustic oscillation system. Mechanical-acoustic oscillations are generated in the piezo motor by a PZT-stack and transmitted to an oscillator element, and then from the oscillator element to a load action element. At high frequencies, when dimensions of the oscillator are proportionate to the wavelength, the energy is transmitted by means of acoustic waves. In this case, mechanical waves practically are not involved in the energy transmission process. This thesis shows a method for selecting the material of a mechanical-acoustic oscillation system according to the efficiency of the acoustic energy transmission via a piezoelectric layered structure.

  3. Chemical gas sensors based on functionalized self-actuated piezo-resistive cantilevers

    OpenAIRE

    Filenko, Denys

    2008-01-01

    Der Schwerpunkt dieser Arbeit liegt in der Anwendung funktionalisierter Mikrocantilever mit integrierter bimorpher Aktuation und piezo-resistiver Detektion als chemische Gassensoren für den schnellen, tragbaren und preisgünstigen Nachweis verschiedener flüchtiger Substanzen. Besondere Beachtung erfährt die Verbesserung der Cantilever-Arbeitsleistung durch den Betrieb in speziellen Modi. Weiterer Schwerpunkt liegt in der Untersuchung von spezifischen Sorptionswechselwirkungen und Anwendung von...

  4. Detecting Liquefied Petroleum Gas (LPG) at Room Temperature Using ZnSnO3/ZnO Nanowire Piezo-Nanogenerator as Self-Powered Gas Sensor.

    Science.gov (United States)

    Fu, Yongming; Nie, Yuxin; Zhao, Yayu; Wang, Penglei; Xing, Lili; Zhang, Yan; Xue, Xinyu

    2015-05-20

    High sensitivity, selectivity, and reliability have been achieved from ZnSnO3/ZnO nanowire (NW) piezo-nanogenerator (NG) as self-powered gas sensor (SPGS) for detecting liquefied petroleum gas (LPG) at room temperature (RT). After being exposed to 8000 ppm LPG, the output piezo-voltage of ZnSnO3/ZnO NW SPGS under compressive deformation is 0.089 V, much smaller than that in air ambience (0.533 V). The sensitivity of the SPGS against 8000 ppm LPG is up to 83.23, and the low limit of detection is 600 ppm. The SPGS has lower sensitivity against H2S, H2, ethanol, methanol and saturated water vapor than LPG, indicating good selectivity for detecting LPG. After two months, the decline of the sensing performance is less than 6%. Such piezo-LPG sensing at RT can be ascribed to the new piezo-surface coupling effect of ZnSnO3/ZnO nanocomposites. The practical application of the device driven by human motion has also been simply demonstrated. This work provides a novel approach to fabricate RT-LPG sensors and promotes the development of self-powered sensing system.

  5. Prototype Control System for Compensation of Superconducting Cavities Detuning Using Piezoelectric Actuators

    Science.gov (United States)

    Przygoda, K.; Piotrowski, A.; Jablonski, G.; Makowski, D.; Pozniak, T.; Napieralski, A.

    2009-08-01

    Pulsed operation of high gradient superconducting radio frequency (SCRF) cavities results in dynamic Lorentz force detuning (LFD) approaching or exceeding the bandwidth of the cavity of order of a few hundreds of Hz. The resulting modulation of the resonance frequency of the cavity is leading to a perturbation of the amplitude and phase of the accelerating field, which can be controlled only at the expense of RF power. Presently, at various labs, a piezoelectric fast tuner based on an active compensation scheme for the resonance frequency control of the cavity is under study. The tests already performed in the Free Electron Laser in Hamburg (FLASH), proved the possibility of Lorentz force detuning compensation by the means of the piezo element excited with the single period of sine wave prior to the RF pulse. The X-Ray Free Electron Laser (X-FEL) accelerator, which is now under development in Deutsche Elektronen-Synchrotron (DESY), will consists of around 800 cavities with a fast tuner fixture including the actuator/sensor configuration. Therefore, it is necessary to design a distributed control system which would be able to supervise around 25 RF stations, each one comprised of 32 cavities. The Advanced Telecomunications Computing Architecture (ATCA) was chosen to design, develop, and build a Low Level Radio Frequency (LLRF) controller for X-FEL. The prototype control system for Lorentz force detuning compensation was designed and developed. The control applications applied in the system were fitted to the main framework of interfaces and communication protocols proposed for the ATCA-based LLRF control system. The paper presents the general view of a designed control system and shows the first experimental results from the tests carried out in FLASH facility. Moreover, the possibilities for integration of the piezo control system to the ATCA standards are discussed.

  6. Thermal hydraulic evaluation for an experimental facility to investigate pressurized thermal shock (PTS) in CDTN/CNEN

    International Nuclear Information System (INIS)

    Palmieri, Elcio T.; Navarro, Moyses A.; Aronne, Ivam D.; Terra, Jose L.

    2002-01-01

    The goal of the work presented in this paper is to provide necessary thermal hydraulics information to the design of an experimental installation to investigate the Pressurized Thermal Shock (PTS) to be implemented at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN). The envisaged installation has a test section that represents, in a small scale, a pressure vessel of a nuclear reactor. This test section will be heated and then exposed to a PTS in order to evaluate the appearance and development of cracks. To verify the behavior of the temperatures of the pressure vessel after a sudden flood through the annulus, calculations were made using the RELAP5/MOD 3.2.2 gamma code. Different outer radiuses were studied for the annular region. The results showed that the smaller annulus spacing (20 mm) anticipates the wetting of the surface and produces a higher cooling of the external surface, which stays completely wet for a longer time. (author)

  7. Enhanced Performance of a Self-Powered Organic/Inorganic Photodetector by Pyro-Phototronic and Piezo-Phototronic Effects.

    Science.gov (United States)

    Peng, Wenbo; Wang, Xingfu; Yu, Ruomeng; Dai, Yejing; Zou, Haiyang; Wang, Aurelia C; He, Yongning; Wang, Zhong Lin

    2017-06-01

    Self-powered photodetectors (PDs) have long been realized by utilizing photovoltaic effect and their performances can be effectively enhanced by introducing the piezo-phototronic effect. Recently, a novel pyro-phototronic effect is invented as an alternative approach for performance enhancement of self-powered PDs. Here, a self-powered organic/inorganic PD is demonstrated and the influences of externally applied strain on the pyro-phototronic and the photovoltaic effects are thoroughly investigated. Under 325 nm 2.30 mW cm -2 UV illumination and at a -0.45% compressive strain, the PD's photocurrent is dramatically enhanced from ≈14.5 to ≈103 nA by combining the pyro-phototronic and piezo-phototronic effects together, showing a significant improvement of over 600%. Theoretical simulations have been carried out via the finite element method to propose the underlying working mechanism. Moreover, the pyro-phototronic effect can be introduced by applying a -0.45% compressive strain to greatly enhance the PD's response to 442 nm illumination, including photocurrent, rise time, and fall time. This work provides in-depth understandings about the pyro-phototronic and the piezo-phototronic effects on the performances of self-powered PD to light sources with different wavelengths and indicates huge potential of these two effects in optoelectronic devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Wound healing of osteotomy defects prepared with piezo or conventional surgical instruments: a pilot study in rabbits.

    Science.gov (United States)

    Ma, Li; Mattheos, Nikos; Sun, Yan; Liu, Xi Ling; Yip Chui, Ying; Lang, Niklaus Peter

    2015-08-01

    The aim of the present study was to evaluate and compare the wound-healing process following osteotomies performed with either conventional rotary burs or piezoelectric surgery in a rabbit model. Two types of osteotomy window defects of the nasal cavities were prepared on the nasal bone of 16 adult New Zealand white rabbits with either a conventional rotary bur or piezo surgery. The defects were covered with a resorbable membrane. Four animals were killed at 1, 2, 3, and 5 weeks after the surgical procedure, respectively. Histological and morphometric evaluations were performed to assess the volumetric density of various tissue components: the blood clot, vascularized structures, provisional matrix, osteoid, mineralized bone, bone debris, residual tissue, and old bone. Significantly more bone debris was found at 1 week in the conventionally-prepared defects compared to the piezo surgically-prepared defects. At 2 and 3 weeks, a newly-formed hard tissue bridge, mainly composed of woven bone, was seen; however, no statistically-significant differences were observed. At 5 weeks, the defects were completely filled with newly-formed bone. The defects prepared by piezo surgery showed a significantly decreased proportion of bone debris at 1 week, compared to conventional rotary bur defect. © 2014 Wiley Publishing Asia Pty Ltd.

  9. Influence of combined therapy with prospidin and methotrexate on radiological progression, functional status and quality of life in pts with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    O. V. Simonova

    2004-01-01

    Full Text Available Objective. To evaluate influence of combination therapy with prospidin (P and methotrexate (MTX on X-ray progression, functional status (FS and quality of life (QL in patients with rheumatoid arthritis (RA in comparison with MTX monotherapy. Material and methods. 143 RA pts (129 female and 14 male were studied. Of them, there were. Mean age was 45.5±5.l years. Average duration of the disease was 4.5 years. 20 pts had II and 123 - 111 degree of RA activity. The second X-ray stage according to Steinbroker dominated. 72 pts of group I received P+MTX combination therapy. The therapy included intravenous drip-feed of P 200-300 mg per week in 200ml of 5% glucose and MTX 10 mg per week 1M. The maintaining therapy included P 100-200 mg per week IM and MTX 10 mg per week. 71 patients of group II received MTX monotherapy 10 mg per week. X-ray progression assessment was performed according to Sharp method. FS was evaluated with the HAQ questionnaire, Lee test. QL was evaluated with SF-36 scale. Pts were examined before and after I, 2, 3, 6 and 12 months of treatment. Results. There was no increase of X-ray progression of the disease in case of P+MTX therapy as compared with MTX monotherapy. Both methods resulted in improvement of FS parameters and physical health. Combination therapy significantly improved psychological health as well.

  10. A Study on AE Signal Analysis of Composite Materials Using Matrix Piezo Electric Sensor

    International Nuclear Information System (INIS)

    Yu, Yeun Ho; Choi, Jin Ho; Kweon, Jin Hwe

    2007-01-01

    As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on non-destructive testing methods has become an important research area for improving their reliability and safety. AE (acoustic emission) can evaluate the defects by detecting the emitting strain energy when elastic waves are generated by the initiation and growth of crack, plastic deformation, fiber breakage, matrix cleavage, or delamination. In the paper, AE signals generated under uniaxial tension were measured and analyzed using the 8x8 matrix piezo electric sensor. The electronic circuit to control the transmitting distance of AE signals was designed and constructed. The optical data storage system was also designed to store the AE signal of 64 channels using LED (light emitting diode) elements. From the tests, it was shown that the source location and propagation path of AE signals in composite materials could be detected effectively by the 8x8 matrix piezo electric sensor

  11. An experimental and theoretical investigation of a fuel system tuner for the suppression of combustion driven oscillations

    Science.gov (United States)

    Scarborough, David E.

    Manufacturers of commercial, power-generating, gas turbine engines continue to develop combustors that produce lower emissions of nitrogen oxides (NO x) in order to meet the environmental standards of governments around the world. Lean, premixed combustion technology is one technique used to reduce NOx emissions in many current power and energy generating systems. However, lean, premixed combustors are susceptible to thermo-acoustic oscillations, which are pressure and heat-release fluctuations that occur because of a coupling between the combustion process and the natural acoustic modes of the system. These pressure oscillations lead to premature failure of system components, resulting in very costly maintenance and downtime. Therefore, a great deal of work has gone into developing methods to prevent or eliminate these combustion instabilities. This dissertation presents the results of a theoretical and experimental investigation of a novel Fuel System Tuner (FST) used to damp detrimental combustion oscillations in a gas turbine combustor by changing the fuel supply system impedance, which controls the amplitude and phase of the fuel flowrate. When the FST is properly tuned, the heat release oscillations resulting from the fuel-air ratio oscillations damp, rather than drive, the combustor acoustic pressure oscillations. A feasibility study was conducted to prove the validity of the basic idea and to develop some basic guidelines for designing the FST. Acoustic models for the subcomponents of the FST were developed, and these models were experimentally verified using a two-microphone impedance tube. Models useful for designing, analyzing, and predicting the performance of the FST were developed and used to demonstrate the effectiveness of the FST. Experimental tests showed that the FST reduced the acoustic pressure amplitude of an unstable, model, gas-turbine combustor over a wide range of operating conditions and combustor configurations. Finally, combustor

  12. Piezo-Phototronic Enhanced UV Sensing Based on a Nanowire Photodetector Array.

    Science.gov (United States)

    Han, Xun; Du, Weiming; Yu, Ruomeng; Pan, Caofeng; Wang, Zhong Lin

    2015-12-22

    A large array of Schottky UV photodetectors (PDs) based on vertical aligned ZnO nanowires is achieved. By introducing the piezo-phototronic effect, the performance of the PD array is enhanced up to seven times in photoreponsivity, six times in sensitivity, and 2.8 times in detection limit. The UV PD array may have applications in optoelectronic systems, adaptive optical computing, and communication. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Enhancing the Efficiency of Silicon-Based Solar Cells by the Piezo-Phototronic Effect.

    Science.gov (United States)

    Zhu, Laipan; Wang, Longfei; Pan, Caofeng; Chen, Libo; Xue, Fei; Chen, Baodong; Yang, Leijing; Su, Li; Wang, Zhong Lin

    2017-02-28

    Although there are numerous approaches for fabricating solar cells, the silicon-based photovoltaics are still the most widely used in industry and around the world. A small increase in the efficiency of silicon-based solar cells has a huge economic impact and practical importance. We fabricate a silicon-based nanoheterostructure (p + -Si/p-Si/n + -Si (and n-Si)/n-ZnO nanowire (NW) array) photovoltaic device and demonstrate the enhanced device performance through significantly enhanced light absorption by NW array and effective charge carrier separation by the piezo-phototronic effect. The strain-induced piezoelectric polarization charges created at n-doped Si-ZnO interfaces can effectively modulate the corresponding band structure and electron gas trapped in the n + -Si/n-ZnO NW nanoheterostructure and thus enhance the transport process of local charge carriers. The efficiency of the solar cell was improved from 8.97% to 9.51% by simply applying a static compress strain. This study indicates that the piezo-phototronic effect can enhance the performance of a large-scale silicon-based solar cell, with great potential for industrial applications.

  14. Inactivation of Mechanically Activated Piezo1 Ion Channels Is Determined by the C-Terminal Extracellular Domain and the Inner Pore Helix

    Directory of Open Access Journals (Sweden)

    Jason Wu

    2017-11-01

    Full Text Available Piezo proteins form mechanically activated ion channels that are responsible for our sense of light touch, proprioception, and vascular blood flow. Upon activation by mechanical stimuli, Piezo channels rapidly inactivate in a voltage-dependent manner through an unknown mechanism. Inactivation of Piezo channels is physiologically important, as it modulates overall mechanical sensitivity, gives rise to frequency filtering of repetitive mechanical stimuli, and is itself the target of numerous human disease-related channelopathies that are not well understood mechanistically. Here, we identify the globular C-terminal extracellular domain as a structure that is sufficient to confer the time course of inactivation and a single positively charged lysine residue at the adjacent inner pore helix as being required for its voltage dependence. Our results are consistent with a mechanism for inactivation that is mediated through voltage-dependent conformations of the inner pore helix and allosteric coupling with the C-terminal extracellular domain.

  15. Entrapped air bubbles in piezo-driven inkjet printing: their effect on the droplet velocity

    NARCIS (Netherlands)

    Jong, de J.; Jeurissen, R.J.M.; Borel, H.; Berg, van den M.; Versluis, M.; Wijshoff, H.M.A.; Prosperetti, A.; Reinten, H.; Lohse, D.

    2006-01-01

    Air bubbles entrapped in the ink channel are a major problem in piezo-driven inkjet printing. They grow by rectified diffusion and eventually counteract the pressure buildup at the nozzle, leading to a breakdown of the jetting process. Experimental results on the droplet velocity udrop as a function

  16. Entrapped air bubbles in piezo-driven inkjet printing: Their effect on the droplet velocity

    NARCIS (Netherlands)

    de Jong, J.; Jeurissen, R.J.M.; Borel, Huub; van den Berg, Marc; Wijshoff, Herman; Versluis, Michel; Wijshoff, H.; Reinten, Hans; Prosperetti, Andrea; Lohse, Detlef

    2006-01-01

    Air bubbles entrapped in the ink channel are a major problem in piezo-driven inkjet printing. They grow by rectified diffusion and eventually counteract the pressure buildup at the nozzle, leading to a breakdown of the jetting process. Experimental results on the droplet velocity udrop as a function

  17. Class IIa bacteriocin resistance in Enterococcus faecalis V583: The mannose PTS operon mediates global transcriptional responses

    Directory of Open Access Journals (Sweden)

    Opsata Mona

    2010-08-01

    Full Text Available Abstract Background The class IIa bacteriocin, pediocin PA-1, has clear potential as food preservative and in the medical field to be used against Gram negative pathogen species as Enterococcus faecalis and Listeria monocytogenes. Resistance towards class IIa bacteriocins appear in laboratory and characterization of these phenotypes is important for their application. To gain insight into bacteriocin resistance we studied mutants of E. faecalis V583 resistant to pediocin PA-1 by use of transcriptomic analyses. Results Mutants of E. faecalis V583 resistant to pediocin PA-1 were isolated, and their gene expression profiles were analyzed and compared to the wild type using whole-genome microarray. Significantly altered transcription was detected from about 200 genes; most of them encoding proteins involved in energy metabolism and transport. Glycolytic genes were down-regulated in the mutants, but most of the genes showing differential expression were up-regulated. The data indicate that the mutants were relieved from glucose repression and putative catabolic responsive elements (cre could be identified in the upstream regions of 70% of the differentially expressed genes. Bacteriocin resistance was caused by reduced expression of the mpt operon encoding the mannose-specific phosphoenolpyruvate:carbohydrate phosphotransferase system (PTS, and the same transcriptional changes were seen in a mptD-inactivated mutant. This mutant also had decreased transcription of the whole mpt operon, showing that the PTS is involved in its own transcriptional regulation. Conclusion Our data confirm the important role of mannose PTS in class IIa bacteriocin sensitivity and we demonstrate its importance involving global carbon catabolite control.

  18. Validation of the Large Interface Method of NEPTUNE{sub C}FD 1.0.8 for Pressurized Thermal Shock (PTS) applications

    Energy Technology Data Exchange (ETDEWEB)

    Coste, P., E-mail: pierre.coste@cea.fr [CEA, DEN, DER/SSTH, F-38054 Grenoble (France); Lavieville, J. [Electricite de France, Chatou (France); Pouvreau, J. [CEA, DEN, DER/SSTH, F-38054 Grenoble (France); Baudry, C.; Guingo, M.; Douce, A. [Electricite de France, Chatou (France)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer The two-phase Pressurized Thermal Shock (PTS) is a key thermohydraulics issue for PWR safety. Black-Right-Pointing-Pointer The dynamic and condensation models are firstly validated separately. Black-Right-Pointing-Pointer Then the global validation is done with the COSI experiment. Black-Right-Pointing-Pointer All the calculations performed with the same set of models both in the Large Interface Method and in the k-{epsilon} approach for turbulence substantiate the application of the tool to PTS. - Abstract: NEPTUNE{sub C}FD is a code based on a 3D transient Eulerian two-fluid model. One of the main application targets is the two-phase Pressurized Thermal Shock (PTS), which is related to PWR Reactor Pressure Vessel (RPV) lifetime safety studies, when sub-cooled water from Emergency Core Cooling (ECC) system is injected into the possibly uncovered cold leg and penetrates into the RPV downcomer. Five experiments were selected for the validation, a selection reviewed by a panel of European experts. The dynamic models are validated with a co-current smooth and wavy air-water stratified flow in a rectangular channel with detailed measurements of turbulence and velocities. The condensation models are validated with a co-current smooth and wavy steam-water stratified flow in a rectangular channel with measurements of the steam flow rates. The dynamic models are validated in the situation of a jet impinging a pool free surface with two experiments dealing with a water jet impingement on a water pool free surface in air environment. Finally, all the models involved in the reactor conditions are validated with the COSI experiment. The calculations are done with the same set of Large Interface Method models and a RANS (k-{epsilon}) approach for turbulence. They substantiate the application of the tool to PTS studies.

  19. Infrared imaging and acoustic sizing of a bubble inside a MEMS piezo ink channel

    NARCIS (Netherlands)

    Bos, van der A.; Segers, T.; Jeurissen, R.J.M.; Berg, van den M.; Reinten, H.; Wijshoff, H.M.A.; Versluis, M.; Lohse, D.

    2011-01-01

    Piezo drop-on-demand inkjet printers are used in an increasing number of applications because of their reliable deposition of droplets onto a substrate. Droplets of a few picoliters are ejected from an inkjet nozzle at frequencies of up to 100 kHz. However, the entrapment of an air microbubble in

  20. Contribution of current carrier mobility variation to piezo-resistive effect in SmS

    International Nuclear Information System (INIS)

    Vasil'ev, L.N.; Kaminskij, V.V.

    1999-01-01

    The value of the contribution from the change in the current carriers mobility and pressure to the piezo-resistive effect value in the materials on the basis of the samarium, monosulfide is studied. The conclusion, that the value of the piezoresistance of comprehensive compression should not exceed 7x10 -3 MPa -1 at T=300 K, experimental data [ru

  1. Master-slave control with trajectory planning and Bouc-Wen model for tracking control of piezo-driven stage

    Science.gov (United States)

    Lu, Xiaojun; Liu, Changli; Chen, Lei

    2018-04-01

    In this paper, a redundant Piezo-driven stage having 3RRR compliant mechanism is introduced, we propose the master-slave control with trajectory planning (MSCTP) strategy and Bouc-Wen model to improve its micro-motion tracking performance. The advantage of the proposed controller lies in that its implementation only requires a simple control strategy without the complexity of modeling to avoid the master PEA's tracking error. The dynamic model of slave PEA system with Bouc-Wen hysteresis is established and identified via particle swarm optimization (PSO) approach. The Piezo-driven stage with operating period T=1s and 2s is implemented to track a prescribed circle. The simulation results show that MSCTP with Bouc-Wen model reduces the trajectory tracking errors to the range of the accuracy of our available measurement.

  2. Piezo-phototronic UV/visible photosensing with optical-fiber-nanowire hybridized structures.

    Science.gov (United States)

    Wang, Zhaona; Yu, Ruomeng; Pan, Caofeng; Liu, Ying; Ding, Yong; Wang, Zhong Lin

    2015-03-04

    An optical-fiber-nanowire hybridized UV-visible photodetector (PD) is reported. The PD is designed to allow direct integration in optical communication systems without requiring the use of couplers via fiber-welding technology. The PD works in two modes: axial and off-axial illumination mode. By using the piezo-phototronic effect, the performance of the PD is enhanced/optimized by up to 718% in sensitivity and 2067% in photoresponsivity. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Two-phase CFD PTS validation in an extended range of thermohydraulics conditions covered by the COSI experiment

    International Nuclear Information System (INIS)

    Coste, P.; Ortolan, A.

    2014-01-01

    Highlights: • Models for large interfaces in two-phase CFD were developed for PTS. • The COSI experiment is used for NEPTUNE C FD integral validation. • COSI is a PWR cold leg scaled 1/100 for volume. • Fifty runs are calculated, covering a large range of flow configurations. • The CFD predicting capability is analysed using global and local measurements. - Abstract: In the context of the Pressurized Water Reactors (PWR) life duration safety studies, some models were developed to address the Pressurized Thermal Shock (PTS) from the two-phase CFD angle, dealing with interfaces much larger than cells size and with direct contact condensation. Such models were implemented in NEPTUNE C FD, a 3D transient Eulerian two-fluid model. The COSI experiment is used for its integral validation. It represents a cold leg scaled 1/100 for volume and power from a 900 MW PWR under a large range of LOCA PTS conditions. In this study, the CFD is evaluated in the whole range of parameters and flow configurations covered by the experiment. In a first step, a single choice of mesh and CFD models parameters is fixed and justified. In a second step, fifty runs are calculated. The CFD predicting capability is analysed, comparing the liquid temperature and the total condensation rate with the experiment, discussing their dependency on the inlet cold liquid rate, on the liquid level in the cold leg and on the difference between co-current and counter-current runs. It is shown that NEPTUNE C FD 1.0.8 calculates with a fair agreement a large range of flow configurations related to ECCS injection and steam condensation

  4. Numerical Modelling of a Piezo Roof Harvesting System: The Right Component Selection

    Directory of Open Access Journals (Sweden)

    Di Leo Romeo

    2017-06-01

    Full Text Available The present work focuses on a first study for a piezoelectric harvesting system, finalized to the obtaining of electrical energy from the kinetic energy of rainy precipitation, a renewable energy source not really considered until now. The system, after the realization, can be collocated on the roof of an house, configuring a “Piezo Roof Harvesting System”. After presenting a state of art of the harvesting systems from environmental energy, linked to vibrations, using piezoelectric structures, and of piezoelectric harvesting systems functioning with rain, the authors propose an analysis of the fundamental features of rainy precipitations for the definition of the harvesting system. Then, four key patterns for the realization of a piezoelectric energy harvesting system are discussed and analysed, arriving to the choice of a cantilever beam scheme, in which the piezoelectric material works in 31 mode. An electro-mechanical model for the simulation of performance of the unit for the energetic conversion, composed of three blocks, is proposed. The model is used for a simulation campaign to perform the final choice of the more suitable piezoelectric unit, available on the market, which will be adopted for the realization of the “Piezo Roof Harvesting System”.

  5. Active Damping of a Piezoelectric Tube Scanner using Self-Sensing Piezo Actuation

    Science.gov (United States)

    Kuiper, S.; Schitter, G.

    2010-01-01

    In most Atomic Force Microscopes (AFM), a piezoelectric tube scanner is used to position the sample underneath the measurement probe. Oscillations stemming from the weakly damped resonances of the tube scanner are a major source of image distortion, putting a limitation on the achievable imaging speed. This paper demonstrates active damping of these oscillations in multiple scanning axes without the need for additional position sensors. By connecting the tube scanner in a capacitive bridge circuit the scanner oscillations can be measured in both scanning axes, using the same piezo material as an actuator and sensor simultaneously. In order to compensate for circuit imbalance caused by hysteresis in the piezo element, an adaptive balancing circuit is used. The obtained measurement signal is used for feedback control, reducing the resonance peaks in both scanning axes by 18 dB and the cross-coupling at those frequencies by 30 dB. Experimental results demonstrate a significant reduction in scanner oscillations when applying the typical triangular scanning signals, as well as a strong reduction in coupling induced oscillations. Recorded AFM images show a considerable reduction in image distortion due to the proposed control method, enabling artifact free AFM imaging at a speed of 122 lines per second with a standard piezoelectric tube scanner. PMID:26412944

  6. Theoretical and experimental evaluation of piezo-optic parameters and photoelastic constant in tetragonal PWO.

    Science.gov (United States)

    Natali, Pier Paolo; Montalto, Luigi; Daví, Fabrizio; Mengucci, Paolo; Ciriaco, Andrea; Paone, Nicola; Rinaldi, Daniele

    2018-02-01

    The tetragonal PbWO 4 (PWO) is one of the most important scintillating crystals, being used both in the Compact Muon Solenoid (CMS) experiment at the European Organization for Nuclear Research (CERN) and in the PANDA project at the Facility for Antiproton and Ion Research (FAIR). Light yield and other relevant scintillation properties depend, among many factors, also on the crystal mechanical quality. Accordingly, a detailed knowledge of crystal piezo-optic properties is a mandatory step toward understanding elasto-optic behavior and performing crystal quality control. In this paper, we evaluate for the first time, to the best of our knowledge, by means of both photoelastic and x-ray measurements, some components of the piezo-optic tensor; moreover, when the crystal is acted upon by a uniaxial stress, we obtain an evaluation for the rotation angle of the optic plane under stress as well as the photoelastic constant. These parameters are necessary to detect the residual stresses within the crystal, if any, and to give an overall quality measure. Such a methodology is in general suitable for any tetragonal crystals.

  7. Modification of the process dynamics in micro-EDM by means of an additional piezo-control system

    Science.gov (United States)

    Herzig, M.; Berger, T.; Schulze, H.-P.; Hackert-Oschätzchen, M.; Kröning, O.; Schubert, A.

    2017-10-01

    For the application of spark erosion in micro- and precision manufacturing, it is particularly important that small structures with small spark gaps can be machined in the range of a few micrometers. Due to the application of an additional high- dynamic piezo positioning system, smaller feed steps can be implemented which ensure a higher process stability. This additional feed system can be adapted to existing feed systems, whereby the process variable to be influenced is the spark gap. The primary feed system does not have to be directly influenced. The article shows how the structures of parallel regulation circuits for such operating piezo positioning systems are constructed and how they can improve the productivity, the machining accuracy and the surface quality. A selected example shows how the structural design of the highly dynamic system can be designed for different process parameters of industrial basic systems.

  8. Model-Based Control of a Nonlinear Aircraft Engine Simulation using an Optimal Tuner Kalman Filter Approach

    Science.gov (United States)

    Connolly, Joseph W.; Csank, Jeffrey Thomas; Chicatelli, Amy; Kilver, Jacob

    2013-01-01

    This paper covers the development of a model-based engine control (MBEC) methodology featuring a self tuning on-board model applied to an aircraft turbofan engine simulation. Here, the Commercial Modular Aero-Propulsion System Simulation 40,000 (CMAPSS40k) serves as the MBEC application engine. CMAPSS40k is capable of modeling realistic engine performance, allowing for a verification of the MBEC over a wide range of operating points. The on-board model is a piece-wise linear model derived from CMAPSS40k and updated using an optimal tuner Kalman Filter (OTKF) estimation routine, which enables the on-board model to self-tune to account for engine performance variations. The focus here is on developing a methodology for MBEC with direct control of estimated parameters of interest such as thrust and stall margins. Investigations using the MBEC to provide a stall margin limit for the controller protection logic are presented that could provide benefits over a simple acceleration schedule that is currently used in traditional engine control architectures.

  9. An evaluation of analysis methodologies for predicting cleavage arrest of a deep crack in an RPV subjected to PTS loading conditions

    International Nuclear Information System (INIS)

    Keeney-Walker, J.; Bass, B.R.

    1992-01-01

    Several calculational procedures are compared for predicting cleavage arrest of a deep crack in the wall of a prototypical reactor pressure vessel (RPV) subjected to pressurized-thermal-shock (PTS) types of loading conditions. Three procedures examined in this study utilized the following models: (1) a static finite-element model (full bending); (2) a radially constrained static model; and (3) a thermoelastic dynamic finite-element model. A PTS transient loading condition was selected that produced a deep arrest of an axially-oriented initially shallow crack according to calculational results obtained from the static (full-bending) model. Results from the two static models were compared with those generated from the detailed thermoelastic dynamic finite-element analysis. The dynamic analyses modeled cleavage-crack propagation using node-release technique and an application-mode methodology based on dynamic fracture toughness curves generated from measured data. Comparisons presented here indicate that the degree to which dynamic solutions can be approximated by static models is highly dependent on several factors, including the material dynamic fracture curves and the propensity for cleavage reinitiation of the arrested crack under PTS loading conditions. Additional work is required to develop and validate a satisfactory dynamic fracture toughness model applicable to postcleavage arrest conditions in an RPV

  10. Predicting the dental implant stability based on the antiresonance phase of a piezo-based impedance sensor

    Directory of Open Access Journals (Sweden)

    Paramita Banerjee

    2017-01-01

    Full Text Available Background: The stability of dental implants (DIs in in vivo tests can be determined using noninvasive resonance frequency analysis technique. A low-cost piezo-based sensor has been developed for this purpose which uses a readily available two-terminal piezo element, to which a metal substrate is adhesively glued for attaching the implant. Aim: The attainment of implant stability in dynamic tests using this sensor must be standardized in terms of the major antiresonance (AR in the impedance phase responses using sensor-DI assembly. This will be used to predetermine the dimensions of the glued metal substrate in the sensor design. Materials and Methods: Multiple sensors with varying sensor dimensions were developed. Static and dynamic impedance studies were performed on these and corresponding sensor-implant assemblies. Static tests as well as in vitro tests with the sensor-implant assembly dipped in a standardized dental plaster mixture were performed in controlled laboratory conditions. Results: The probability of acceptance of the hypothesis has been checked using binomial distribution with a significance level of 5%. Statistically observed that for 95% of the cases where the DI becomes stable in dental plaster, both AR phase and AR frequency (ARF return to their corresponding static values. Furthermore, for a piezo element, whose ARF is within 6–6.6 kHz, the sensor yields maximal phase when the length of the metallic strip is 2 cm. Conclusions: Experimental validation supports both claims. Hence, this work can be extended to in vivo DI stability determination and design aspects of the corresponding sensor.

  11. Development of Pneumatic Transport System (PTS) for safe handling of uranium oxide powder in UMP/UED

    International Nuclear Information System (INIS)

    Manna, S.; Satpati, S.K.; Roy, S.B.

    2009-01-01

    Tonnage quantity radioactive uranium oxide powder of particle size sub micron to 100 micron is handled in Uranium Metal Plant (UMP), UED/BARC for production of nuclear grade uranium metal, required for fuelling research reactors - Dhruva and Cirus. A Pneumatic Transfer System (PTS) using vacuum has been introduced and is being used for handling radioactive powder to improve radiation protection

  12. The structure of new germanates, gallates, borates and silicates with laser, piezo, ferroelectric and ion conducting properties

    International Nuclear Information System (INIS)

    Belokonev, E.L.

    1994-01-01

    The results of structure investigation of more than 50 new crystalline germanates, gallates, borogermanates, borates, and silicates with laser, piezo, ferroelectric, and ion-conducting properties are described. The structure - properties relationship is examined. 71 refs.; 24 figs.; 10 tabs

  13. Overview of SNS Cryomodule Performance

    CERN Document Server

    Drury, Michael A; Davis, Kirk; Delayen, Jean R; Grenoble, Christiana; Hicks, William R; King, Larry; Plawski, Tomasz; Powers, Tom; Preble, Joseph P; Wang, Haipeng; Wiseman, Mark

    2005-01-01

    Thomas Jefferson National Accelerating Facility (Jefferson Lab) has completed production of 24 Superconducting Radio Frequency (SRF) cryomodules for the Spallation Neutron Source (SNS) superconducting linac. This includes one medium-beta (0.61) prototype, eleven medium-beta and twelve high-beta (0.81) production cryomodules. Ten medium-beta cryomodules as well as two high beta cryomodules have undergone complete operational performance testing in the Cryomodule Test Facility at Jefferson Lab. The set of tests includes measurements of maximum gradient, unloaded Q (Q0), microphonics, and response to Lorentz forces. The Qext's of the various couplers are measured and the behavior of the higher order mode couplers is examined. The mechanical and piezo tuners are also characterized. The results of these performance tests will be discussed in this paper.

  14. Cryomodule tests of four Tesla-like cavities in the Superconducting RF Test Facility at KEK

    Directory of Open Access Journals (Sweden)

    Eiji Kako

    2010-04-01

    Full Text Available A 6-m cryomodule including four Tesla-like cavities was developed, and was tested in the Superconducting RF Test Facility phase-I at KEK. The performance as a total superconducting cavity system was checked in the cryomodule tests at 2 K with high rf power. One of the four cavities achieved a stable pulsed operation at 32  MV/m, which is higher than the operating accelerating gradient in the ILC. The maximum accelerating gradient (E_{acc,max⁡} obtained in the vertical cw tests was maintained or slightly improved in the cryomodule tests operating in a pulse mode. Compensation of the Lorentz force detuning at 31  MV/m was successfully demonstrated by a piezo tuner and predetuning.

  15. Simultaneously Enhancing Light Emission and Suppressing Efficiency Droop in GaN Microwire-Based Ultraviolet Light-Emitting Diode by the Piezo-Phototronic Effect.

    Science.gov (United States)

    Wang, Xingfu; Peng, Wenbo; Yu, Ruomeng; Zou, Haiyang; Dai, Yejing; Zi, Yunlong; Wu, Changsheng; Li, Shuti; Wang, Zhong Lin

    2017-06-14

    Achievement of p-n homojuncted GaN enables the birth of III-nitride light emitters. Owing to the wurtzite-structure of GaN, piezoelectric polarization charges present at the interface can effectively control/tune the optoelectric behaviors of local charge-carriers (i.e., the piezo-phototronic effect). Here, we demonstrate the significantly enhanced light-output efficiency and suppressed efficiency droop in GaN microwire (MW)-based p-n junction ultraviolet light-emitting diode (UV LED) by the piezo-phototronic effect. By applying a -0.12% static compressive strain perpendicular to the p-n junction interface, the relative external quantum efficiency of the LED is enhanced by over 600%. Furthermore, efficiency droop is markedly reduced from 46.6% to 7.5% and corresponding droop onset current density shifts from 10 to 26.7 A cm -2 . Enhanced electrons confinement and improved holes injection efficiency by the piezo-phototronic effect are revealed and theoretically confirmed as the physical mechanisms. This study offers an unconventional path to develop high efficiency, strong brightness and high power III-nitride light sources.

  16. New piezo driven gas inlet valve for fusion experiments

    International Nuclear Information System (INIS)

    Usselmann, E.; Hemmerich, J.L.; How, J.; Holland, D.; Orchard, J.; Winkel, T.; Schargitz, U.; Pocheim, N.

    1989-01-01

    The gas inlet valves used at the JET experiment are described and their performances are discussed. A new gas-valve development suitable to replace the existing valves at JET and for future use in large fusion experiments is presented. The new valve is equipped with a piezo-electric translator and has a dosing range of 0-800 mbarls -1 for D 2 . The operating mode of the valve is fail-safe closed with a leak-rate of ≤ 10 -9 mbarls -1 . The design, the test results and throughput values in dependence of filling pressure and control voltage are presented and experiences with the prototype valve as a new gas inlet valve for the JET operation are described

  17. High-Precision Control of a Piezo-Driven Nanopositioner Using Fuzzy Logic Controllers

    Directory of Open Access Journals (Sweden)

    Mohammed Altaher

    2018-01-01

    Full Text Available This paper presents single- and dual-loop fuzzy control schemes to precisely control the piezo-driven nanopositioner in the x- and y-axis directions. Various issues are associated with this control problem, such as low stability margin due to the sharp resonant peak, nonlinear dynamics, parameter uncertainty, etc. As such, damping controllers are often utilised to damp the mechanical resonance of the nanopositioners. The Integral Resonant Controller (IRC is used in this paper as a damping controller to damp the mechanical resonance. A further inherent problem is the hysteresis phenomenon (disturbance, which leads to degrading the positioning performance (accuracy of the piezo-driven stage. The common approach to treat this disturbance is to invoke tracking controllers in a closed-loop feedback scheme in conjunction with the damping controllers. The traditional approach uses the Integral Controller (I or Proportional Integral (PI as a tracking controller, whereas this paper introduces the Proportional and Integral (PI-like Fuzzy Logic Controller (FLC as a tracking controller. The effectiveness of the proposed control schemes over conventional schemes is confirmed through comparative simulation studies, and results are presented. The stability boundaries of the proposed control schemes are determined in the same way as with a conventional controller. Robustness against variations in the resonant frequency of the proposed control schemes is verified.

  18. Study of a Piezo-Thermo-Elastic Materials Console

    Directory of Open Access Journals (Sweden)

    hamza madjid berrabah

    2015-09-01

    Full Text Available In the first part of this work, analytical expressions were determined for the stresses through the thickness of a composite beam submitted to electrical excitation. In the second part of this study we are interested in the theory of elasticity, which is used to obtain exact solutions of piezo-thermo-elastic consoles gradually coupled evaluated under different loads. These solutions are used to identify the piezoelectric parameter and thermal coefficients of the materials. In addition, numerical results are obtained for the analysis of the loaded console by two different types of loading. In this study we show also that changing the linear thermal parameters of the material does not affect the distribution of the stress and the induction of the beam. However it affetcs the components of the deformation, electric field, the displacement and the electric potential of the console.

  19. Oxygen Reduction Reaction for Generating H2 O2 through a Piezo-Catalytic Process over Bismuth Oxychloride.

    Science.gov (United States)

    Shao, Dengkui; Zhang, Ling; Sun, Songmei; Wang, Wenzhong

    2018-02-09

    Oxygen reduction reaction (ORR) for generating H 2 O 2 through green pathways have gained much attention in recent years. Herein, we introduce a piezo-catalytic approach to obtain H 2 O 2 over bismuth oxychloride (BiOCl) through an ORR pathway. The piezoelectric response of BiOCl was directly characterized by piezoresponse force microscopy (PFM). The BiOCl exhibits efficient catalytic performance for generating H 2 O 2 (28 μmol h -1 ) only from O 2 and H 2 O, which is above the average level of H 2 O 2 produced by solar-to-chemical processes. A piezo-catalytic mechanism was proposed: with ultrasonic waves, an alternating electric field will be generated over BiOCl, which can drive charge carriers (electrons) to interact with O 2 and H 2 O, then to form H 2 O 2 . © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Experimental tests and validation of calculation criteria of acceptable Tk shift with respect to PTS at VVER

    International Nuclear Information System (INIS)

    Hosnedl, P.; Roubalova, M.; Sik, J.; Priban, M.; Hora, P.; Vales, F.

    2004-01-01

    The following topics were examined: (i) Methodology of fracture tests at temperature gradients and pressurized thermal shock (PTS) cooling tests on large specimens (1500x1200x140 mm) with a designed postulated crack and other smaller cracks in the cooled area (test performed on a ZZ 8000 (80MN) loading stand); (ii) simulation of radiation embrittlement of tested material near the end of the RPV designed life, the material is subjected to standard mechanical property tests and fracture tests of standard test specimens modelling the PTS regime of material loading; (iii) 100% NDT tests of a specimen before the beginning of tests and μTOFD before and after each particular test of a specimen; (iv) on-line monitoring of the test conditions based on instrumentation of a specimen with thermocouples, COD and strain gauges together with on-line monitoring of Acoustic Emission during the tests; (v) calculation of K l at the critical points of the crack front during the test, based on monitored boundary conditions; (vi) fractographic analysis after the fracture of a specimen and evaluation of the whole test. (P.A.)

  1. TRAC analysis and support of Oconee-1 PTS studies

    International Nuclear Information System (INIS)

    Ireland, J.R.

    1983-01-01

    This paper describes the overall pressurized thermal shock (PTS) program at Los Alamos with emphasis on TRAC-PF1 calculations of severe overcooling transients for the Oconee-1 pressurized water reactor (PWR). A summary of results for several calculations are presented for the Oconee-1 PWR along with detailed discussions of two of the most severe overcooling transients predicted [main steam-line break and turbine-bypass valve (TBV) failures]. The calculations performed were plant specific in that details of both the primary and secondary sides were modeled in addition to a detailed model of the plant Integrated Control System (ICS). For the Oconee-1 main steam-line break transient, a minimum downcomer fluid temperature of approx. 405 K was predicted. For the TBV transient involving the failure of one bank of TBVs to close after initially opening following reactor and turbine trips, an extrapolated downcomer fluid temperature of approx. 365 K was estimated. The latter temperature is at the nil-ductility temperature (NDT) limit (approx. 365 K) for Oconee-1

  2. Design and Implementation of Output Feedback Control for Piezo Actuated Structure Using Embedded System

    Directory of Open Access Journals (Sweden)

    R.Maheswari

    2008-06-01

    Full Text Available This paper presents the design of periodic output feedback control using state feedback gain to control the vibration of piezo actuated cantilever beam. The effectiveness of the controller is evaluated through simulation and experimentally by exciting the structure at resonance. Real time implementation of the controller is done using microcontroller. The closed loop eigen values of the system with periodic output feedback and state feedback are identical.

  3. Synthesis of CdS nanorod arrays and their applications in flexible piezo-driven active H2S sensors

    International Nuclear Information System (INIS)

    Wang, Penglei; Deng, Ping; Nie, Yuxin; Zhao, Yayu; Xing, Lili; Xue, Xinyu; Zhang, Yan

    2014-01-01

    A flexible piezo-driven active H 2 S sensor has been fabricated from CdS nanorod arrays. By coupling the piezoelectric and gas sensing properties of CdS nanorods, the piezoelectric output generated by CdS nanorod arrays acts not only as a power source, but also as a response signal to H 2 S. Under externally applied compressive force, the piezoelectric output of CdS nanorod arrays is very sensitive to H 2 S. Upon exposure to 600 ppm H 2 S, the piezoelectric output of the device decreased from 0.32 V (in air) to 0.12 V. Such a flexible device can be driven by the tiny mechanical energy in our living environment, such as human finger pinching. Our research can stimulate a research trend on designing new material systems and device structures for high-performance piezo-driven active gas sensors. (paper)

  4. Enhanced Solar Cell Conversion Efficiency of InGaN/GaN Multiple Quantum Wells by Piezo-Phototronic Effect.

    Science.gov (United States)

    Jiang, Chunyan; Jing, Liang; Huang, Xin; Liu, Mengmeng; Du, Chunhua; Liu, Ting; Pu, Xiong; Hu, Weiguo; Wang, Zhong Lin

    2017-09-26

    The piezo-phototronic effect is the tuning of piezoelectric polarization charges at the interface to largely enhance the efficiency of optoelectronic processes related to carrier separation or recombination. Here, we demonstrated the enhanced short-circuit current density and the conversion efficiency of InGaN/GaN multiple quantum well solar cells with an external stress applied on the device. The external-stress-induced piezoelectric charges generated at the interfaces of InGaN and GaN compensate the piezoelectric charges induced by lattice mismatch stress in the InGaN wells. The energy band realignment is calculated with a self-consistent numerical model to clarify the enhancement mechanism of optical-generated carriers. This research not only theoretically and experimentally proves the piezo-phototronic effect modulated the quantum photovoltaic device but also provides a great promise to maximize the use of solar energy in the current energy revolution.

  5. Integral force feedback control with input shaping: Application to piezo-based scanning systems in ECDLs

    Science.gov (United States)

    Zhang, Meng; Liu, Zhigang; Zhu, Yu; Bu, Mingfan; Hong, Jun

    2017-07-01

    In this paper, a hybrid control system is developed by integrating the closed-loop force feedback and input shaping method to overcome the problem of the hysteresis and dynamic behavior in piezo-based scanning systems and increase the scanning speed of tunable external cavity diode lasers. The flexible hinge and piezoelectric actuators are analyzed, and a dynamic model of the scanning systems is established. A force sensor and an integral controller are utilized in integral force feedback (IFF) to directly augment the damping of the piezoelectric scanning systems. Hysteresis has been effectively eliminated, but the mechanical resonance is still evident. Noticeable residual vibration occurred after the inflection points and then gradually disappeared. For the further control of mechanical resonance, based on the theory of minimum-acceleration trajectory planning, the time-domain input shaping method was developed. The turning sections of a scanning trajectory are replaced by smooth curves, while the linear sections are retained. The IFF method is combined with the input shaping method to control the non-linearity and mechanical resonance in high-speed piezo-based scanning systems. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach.

  6. Integral force feedback control with input shaping: Application to piezo-based scanning systems in ECDLs.

    Science.gov (United States)

    Zhang, Meng; Liu, Zhigang; Zhu, Yu; Bu, Mingfan; Hong, Jun

    2017-07-01

    In this paper, a hybrid control system is developed by integrating the closed-loop force feedback and input shaping method to overcome the problem of the hysteresis and dynamic behavior in piezo-based scanning systems and increase the scanning speed of tunable external cavity diode lasers. The flexible hinge and piezoelectric actuators are analyzed, and a dynamic model of the scanning systems is established. A force sensor and an integral controller are utilized in integral force feedback (IFF) to directly augment the damping of the piezoelectric scanning systems. Hysteresis has been effectively eliminated, but the mechanical resonance is still evident. Noticeable residual vibration occurred after the inflection points and then gradually disappeared. For the further control of mechanical resonance, based on the theory of minimum-acceleration trajectory planning, the time-domain input shaping method was developed. The turning sections of a scanning trajectory are replaced by smooth curves, while the linear sections are retained. The IFF method is combined with the input shaping method to control the non-linearity and mechanical resonance in high-speed piezo-based scanning systems. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach.

  7. Infrared imaging and acoustic sizing of a bubble inside a micro-electro-mechanical system piezo ink channel

    NARCIS (Netherlands)

    van der Bos, J.A.; van der Bos, Arjan; Segers, Tim; Segers, T.J.; Jeurissen, R.J.M.; van den Berg, Marc; Reinten, Hans; Wijshoff, Herman; Wijshoff, H.; Versluis, Michel; Lohse, Detlef

    2011-01-01

    Piezo drop-on-demand inkjet printers are used in an increasing number of applications because of their reliable deposition of droplets onto a substrate. Droplets of a few picoliters are ejected from an inkjet nozzle at frequencies of up to 100 kHz. However, the entrapment of an air microbubble in

  8. Evaluation of the PTS potential in a WWER-1000 following a steam line break

    International Nuclear Information System (INIS)

    Beghini, M.; D'Auria, F.; Galassi, G.M.; Vitale, E.

    1997-01-01

    A qualified nodalization for WWER-1000 is available at DCMN (Dipartimento di Costruzioni Meccaniche e Nucleari) of University of Pisa that is suitable for running with the thermohydraulic system code Relap5/mod3.2. The nodalization consists of about 1400 hydraulic nodes and more than 5000 mesh points for conduction heat transfer. The four loops of the NPP are separately modelled. Detailed information about the plant hardware has been gotten from contacts with Eastern Organizations in Bulgaria, Russia and Ukraine. The qualification of the nodalization has been achieved at a steady state level utilizing a procedure available at DCMN and at a transient level on the basis of operational (planned) transients performed in the Bulgarian Kozloduy-5 NPP and of the unplanned transient occurred at the Ukrainian Zaporosche NPP (April 1995). Data measured in steam generators have also been utilized. The nodalization has been widely applied to the analysis of accident scenarios in WWER-1000, including Large Break LOCA, Small Break LOCA, ATWS, Loss of Feedwater and Station Blackout. The present activity aims at evaluating the potential for PTS (Pressurized Thermal Shock) following a steam line break accident. The thermalhydraulic results were employed as input for a parametric Fracture Mechanics analysis based on conservative hypothesis of the shape and localization of a pre-existing defect. Stress analysis evidenced the effect of partial cooling of the vessel and gave some general indications of the risk for unstable crack propagation under the simulated PTS conditions. (author). 30 refs, 17 figs, 4 tabs

  9. Transferability of results of PTS experiments to the integrity assessment of reactor pressure vessels

    International Nuclear Information System (INIS)

    Roos, E.; Eisele, U.; Stumpfrock, L.

    1997-01-01

    The integrity assessment of the reactor pressure vessel (RPV) is based on the fracture mechanics concept as provided in the code. However this concept covers only the linear-elastic fracture mechanics regime on the basis of the reference temperature RT NDT as derived from charpy impact and drop-weight test. The conservatism of this concept was demonstrated for a variety of different materials covering optimized and lower bound material states with regard to unirradiated and irradiated conditions. For the elastic-plastic regime, methodologies have been developed to describe ductile crack initiation and stable crack growth. The transferability of both, the linear-elastic and elastic-plastic fracture mechanics concept was investigated with the help of large scale specimens focusing on complex loading situations as they result from postulated thermal shock events for the RPV. A series of pressurized thermal shock (PTS) experiments were performed in which the applicability of the fracture mechanics parameters derived from small scale specimen testing could be demonstrated. This includes brittle (static and dynamic) crack initiation and crack arrest in the low charpy energy regime as well as stable crack initiation, stable crack growth and crack arrest in the upper shelf toughness regime. The paper provides the basic material data, the load paths, representative for large complex components as well as experimental and theoretical results of PTS experiments. From these data it can be concluded that the available fracture mechanics concepts can be used to describe the component behavior under transient loading conditions. (author). 26 refs, 12 figs, 1 tab

  10. Evaluation of the PTS potential in a WWER-1000 following a steam line break

    Energy Technology Data Exchange (ETDEWEB)

    Beghini, M; D` Auria, F; Galassi, G M; Vitale, E [Universita degli Studi di Pisa, Dipt. di Costruzioni Meccaniche e Nucleari, Pisa (Italy)

    1997-09-01

    A qualified nodalization for WWER-1000 is available at DCMN (Dipartimento di Costruzioni Meccaniche e Nucleari) of University of Pisa that is suitable for running with the thermohydraulic system code Relap5/mod3.2. The nodalization consists of about 1400 hydraulic nodes and more than 5000 mesh points for conduction heat transfer. The four loops of the NPP are separately modelled. Detailed information about the plant hardware has been gotten from contacts with Eastern Organizations in Bulgaria, Russia and Ukraine. The qualification of the nodalization has been achieved at a steady state level utilizing a procedure available at DCMN and at a transient level on the basis of operational (planned) transients performed in the Bulgarian Kozloduy-5 NPP and of the unplanned transient occurred at the Ukrainian Zaporosche NPP (April 1995). Data measured in steam generators have also been utilized. The nodalization has been widely applied to the analysis of accident scenarios in WWER-1000, including Large Break LOCA, Small Break LOCA, ATWS, Loss of Feedwater and Station Blackout. The present activity aims at evaluating the potential for PTS (Pressurized Thermal Shock) following a steam line break accident. The thermalhydraulic results were employed as input for a parametric Fracture Mechanics analysis based on conservative hypothesis of the shape and localization of a pre-existing defect. Stress analysis evidenced the effect of partial cooling of the vessel and gave some general indications of the risk for unstable crack propagation under the simulated PTS conditions. (author). 30 refs, 17 figs, 4 tabs.

  11. Transferability of results of PTS experiments to the integrity assessment of reactor pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Roos, E; Eisele, U; Stumpfrock, L [MPA Stuttgart (Germany)

    1997-09-01

    The integrity assessment of the reactor pressure vessel (RPV) is based on the fracture mechanics concept as provided in the code. However this concept covers only the linear-elastic fracture mechanics regime on the basis of the reference temperature RT{sub NDT} as derived from charpy impact and drop-weight test. The conservatism of this concept was demonstrated for a variety of different materials covering optimized and lower bound material states with regard to unirradiated and irradiated conditions. For the elastic-plastic regime, methodologies have been developed to describe ductile crack initiation and stable crack growth. The transferability of both, the linear-elastic and elastic-plastic fracture mechanics concept was investigated with the help of large scale specimens focusing on complex loading situations as they result from postulated thermal shock events for the RPV. A series of pressurized thermal shock (PTS) experiments were performed in which the applicability of the fracture mechanics parameters derived from small scale specimen testing could be demonstrated. This includes brittle (static and dynamic) crack initiation and crack arrest in the low charpy energy regime as well as stable crack initiation, stable crack growth and crack arrest in the upper shelf toughness regime. The paper provides the basic material data, the load paths, representative for large complex components as well as experimental and theoretical results of PTS experiments. From these data it can be concluded that the available fracture mechanics concepts can be used to describe the component behavior under transient loading conditions. (author). 26 refs, 12 figs, 1 tab.

  12. Visible-Light Modulation on Lattice Dielectric Responses of a Piezo-Phototronic Soft Material.

    Science.gov (United States)

    Huang, E-Wen; Hsu, Yu-Hsiang; Chuang, Wei-Tsung; Ko, Wen-Ching; Chang, Chung-Kai; Lee, Chih-Kung; Chang, Wen-Chi; Liao, Tzu-Kang; Thong, Hao Cheng

    2015-12-16

    In situ synchrotron X-ray diffraction is used to investigate a three-way piezo-phototronic soft material. This new system is composed of a semi-crystalline poly(vinylidene fluoride-co-trifluoroethylene) piezoelectric polymer and titanium oxide nanoparticles. Under light illumination, photon-induced piezoelectric responses are nearly two times higher at both the lattice-structure and the macroscopic level than under conditions without light illumination. A mechanistic model is proposed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Overview of SNS Cryomodule Performance

    International Nuclear Information System (INIS)

    Michael Drury; Edward Daly; Christiana Grenoble; William Hicks; Lawrence King; Tomasz Plawski; Thomas Powers; Joseph Preble; Haipeng Wang; Mark Wiseman; G. Davis; Jean Delayen

    2005-01-01

    Thomas Jefferson National Accelerating Facility (Jefferson Lab) has completed production of 24 Superconducting Radio Frequency (SRF) cryomodules for the Spallation Neutron Source (SNS) superconducting linac. This includes one medium-β (0.61) prototype, eleven medium-β and twelve high-β (0.81) production cryomodules. Nine medium-β cryomodules as well as two high-β cryomodules have undergone complete operational performance testing in the Cryomodule Test Facility at Jefferson Lab. The set of tests includes measurements of maximum gradient, unloaded Q (Q 0 ), microphonics, and response to Lorentz forces. The Q ext 's of the various couplers are measured and the behavior of the higher order mode couplers is examined. The mechanical and piezo tuners are also characterized. The results of these performance tests will be discussed in this paper

  14. Identification of a type of defects in CdTe crystals by the piezo spectroscopic method

    International Nuclear Information System (INIS)

    Tarbajev, M.Yi.

    1999-01-01

    The dependence of line shifts and the photoluminescence line intensity of bound exciton complexes on the direction of elastic deformation are studied for CdTe crystals at 4.2 K. On the basis of the found differences in piezo optic behavior of excitons bound to neutral donors and acceptors, the method of identification of a type of defects in CdTe crystals is proposed

  15. Impact damage detection in light composite sandwich panels using piezo-based nonlinear vibro-acoustic modulations

    International Nuclear Information System (INIS)

    Pieczonka, L; Ukowski, P; Klepka, A; Staszewski, W J; Uhl, T; Aymerich, F

    2014-01-01

    The nonlinear vibro-acoustic modulation technique is used for impact damage detection in light composite sandwich panels. The method utilizes piezo-based low-frequency vibration and high-frequency ultrasonic excitations. The work presented focuses on the analysis of modulation intensity. The results show that the method can be used for impact damage detection reliably separating damage-related from vibro-acoustic modulations from other intrinsic nonlinear modulations. (paper)

  16. Piezo-phototronic Boolean logic and computation using photon and strain dual-gated nanowire transistors.

    Science.gov (United States)

    Yu, Ruomeng; Wu, Wenzhuo; Pan, Caofeng; Wang, Zhaona; Ding, Yong; Wang, Zhong Lin

    2015-02-04

    Using polarization charges created at the metal-cadmium sulfide interface under strain to gate/modulate electrical transport and optoelectronic processes of charge carriers, the piezo-phototronic effect is applied to process mechanical and optical stimuli into electronic controlling signals. The cascade nanowire networks are demonstrated for achieving logic gates, binary computations, and gated D latches to store information carried by these stimuli. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Monitoring early hydration of reinforced concrete structures using structural parameters identified by piezo sensors via electromechanical impedance technique

    Science.gov (United States)

    Talakokula, Visalakshi; Bhalla, Suresh; Gupta, Ashok

    2018-01-01

    Concrete is the most widely used material in civil engineering construction. Its life begins when the hydration process is activated after mixing the cement granulates with water. In this paper, a non-dimensional hydration parameter, obtained from piezoelectric ceramic (PZT) patches bonded to rebars embedded inside concrete, is employed to monitor the early age hydration of concrete. The non-dimensional hydration parameter is derived from the equivalent stiffness determined from the piezo-impedance transducers using the electro-mechanical impedance (EMI) technique. The focus of the study is to monitor the hydration process of cementitious materials commencing from the early hours and continue till 28 days using single non-dimensional parameter. The experimental results show that the proposed piezo-based non-dimensional hydration parameter is very effective in monitoring the early age hydration, as it has been derived from the refined structural impedance parameters, obtained by eliminating the PZT contribution, and using both the real and imaginary components of the admittance signature.

  18. [Age specific and individual psychological factors of post--traumatic stress (PTS) development of children with after-effects of physical damages indicating medical rehabilitation].

    Science.gov (United States)

    Пятакова, Галина В; Лебедева, Екатерина И; Потявина, Валерия В; Церфус, Диана Н

    children and teenagers having received hard physical damages face a difficult life situation which includes events accompanied by feeling of intensive fear and helplessness. Every child's individual psychological features play an important role in coping with negative psychological after-effects of his/her physical trauma. learning PTS manifestations among children and teenagers with hard physical damages indicating medical rehabilitation. patients of the traumatological department of children's surgery clinic took part in the research: 31 preadolescent children and their parents, 45 teengaers and their parents. Physical damages were received by children clinic's patients in accidents and out of negligence. A survey containing clinical and historical method elements, medical documents; semi-structured interviews for identification of signs of children's post-traumatic stress, a survey for parents for identification of children's traumatic experience, colour matrices and J. Raven black-and-white matrices, S. Rosenzweig frustration tolerance methods (children's and adult version) were used as certain research methods. it was shown that intellectual productivity showings and stable ways of emotional reaction can act as individual psychological factos of PTS development. Age specifics of embeddedness of intellectual features and stable ways of emotional reaction to PTS symptoms development among children and teenagers with hard physical damages. the received results can be used as a base for developing specific approaches for psychological support of children and teenagers having the experience of physical damage and difficult medical rehabilitation.

  19. Effect of the dilution factor on 18FDG and Na18F samples for bacterial endotoxin test using PTS (portable test system)

    International Nuclear Information System (INIS)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z.

    2011-01-01

    18 FDG and Na 18 F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as 18 F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of 18 FDG and Na 18 F for PTS analysis. Two different dilution factors for 18 FDG and 1:10 for Na 18 F were essayed: 1:10 and 1:100. 18 FDG and Na 18 solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for 18 FDG and 1:10 for Na 18 F. The recovery of the product positive control was 98-12% for 18 FDG 1:100 and 104-120% for Na 18 F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for 18 FDG and Na 18 F routine endotoxin test. (author)

  20. Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill

    Science.gov (United States)

    Sherrit, Stewart (Inventor); Bao, Xiaoqi (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor)

    2014-01-01

    A Single Piezo-Actuator Rotary-Hammering (SPaRH) Drill includes a horn actuator having high power piezoelectric materials and a flexure pre-stress to increase the actuators effectiveness. The drill is a low mass, low power, compact coring drill measuring 20-cm high by 7-cm diameter and having a total weight of 2 kg including drive electronics. Using an average power of 50-Watts, the drill basalt is expected to cut basalt at a rate of 0.2 cm/min down to depth of 10-cm and create cuttings and an intact core. The drill is expected to operate under different environments including Martian ambient (6 Torr and down to -50 degree C), and liquid nitrogen temperatures (77 K) and low pressure (<<1 Torr) to simulate lunar polar and Europa conditions. Materials expected to be sampled include Kaolinite, Saddleback Basalt, Limestone, Volcanic Breccia, Siltstone, ice, permafrost and layered rocks with different hardness.

  1. Family and Individual Factors Associated with Substance Involvement and PTS Symptoms among Adolescents in Greater New Orleans after Hurricane Katrina

    Science.gov (United States)

    Rowe, Cynthia L.; La Greca, Annette M.; Alexandersson, Anders

    2010-01-01

    Objective: This study examined the influence of hurricane impact as well as family and individual risk factors on posttraumatic stress (PTS) symptoms and substance involvement among clinically referred adolescents affected by Hurricane Katrina. Method: A total of 80 adolescents (87% male; 13-17 years old; mean age = 15.6 years; 38% minorities) and…

  2. High-bandwidth and flexible tracking control for precision motion with application to a piezo nanopositioner.

    Science.gov (United States)

    Feng, Zhao; Ling, Jie; Ming, Min; Xiao, Xiao-Hui

    2017-08-01

    For precision motion, high-bandwidth and flexible tracking are the two important issues for significant performance improvement. Iterative learning control (ILC) is an effective feedforward control method only for systems that operate strictly repetitively. Although projection ILC can track varying references, the performance is still limited by the fixed-bandwidth Q-filter, especially for triangular waves tracking commonly used in a piezo nanopositioner. In this paper, a wavelet transform-based linear time-varying (LTV) Q-filter design for projection ILC is proposed to compensate high-frequency errors and improve the ability to tracking varying references simultaneously. The LVT Q-filter is designed based on the modulus maximum of wavelet detail coefficients calculated by wavelet transform to determine the high-frequency locations of each iteration with the advantages of avoiding cross-terms and segmenting manually. The proposed approach was verified on a piezo nanopositioner. Experimental results indicate that the proposed approach can locate the high-frequency regions accurately and achieve the best performance under varying references compared with traditional frequency-domain and projection ILC with a fixed-bandwidth Q-filter, which validates that through implementing the LTV filter on projection ILC, high-bandwidth and flexible tracking can be achieved simultaneously by the proposed approach.

  3. Piezo-phototronic effect enhanced UV photodetector based on CuI/ZnO double-shell grown on flexible copper microwire.

    Science.gov (United States)

    Liu, Jingyu; Zhang, Yang; Liu, Caihong; Peng, Mingzeng; Yu, Aifang; Kou, Jinzong; Liu, Wei; Zhai, Junyi; Liu, Juan

    2016-12-01

    In this work, we present a facile, low-cost, and effective approach to fabricate the UV photodetector with a CuI/ZnO double-shell nanostructure which was grown on common copper microwire. The enhanced performances of Cu/CuI/ZnO core/double-shell microwire photodetector resulted from the formation of heterojunction. Benefiting from the piezo-phototronic effect, the presentation of piezocharges can lower the barrier height and facilitate the charge transport across heterojunction. The photosensing abilities of the Cu/CuI/ZnO core/double-shell microwire detector are investigated under different UV light densities and strain conditions. We demonstrate the I-V characteristic of the as-prepared core/double-shell device; it is quite sensitive to applied strain, which indicates that the piezo-phototronic effect plays an essential role in facilitating charge carrier transport across the CuI/ZnO heterojunction, then the performance of the device is further boosted under external strain.

  4. Ultra-Precision Measurement and Control of Angle Motion in Piezo-Based Platforms Using Strain Gauge Sensors and a Robust Composite Controller

    Science.gov (United States)

    Liu, Lei; Bai, Yu-Guang; Zhang, Da-Li; Wu, Zhi-Gang

    2013-01-01

    The measurement and control strategy of a piezo-based platform by using strain gauge sensors (SGS) and a robust composite controller is investigated in this paper. First, the experimental setup is constructed by using a piezo-based platform, SGS sensors, an AD5435 platform and two voltage amplifiers. Then, the measurement strategy to measure the tip/tilt angles accurately in the order of sub-μrad is presented. A comprehensive composite control strategy design to enhance the tracking accuracy with a novel driving principle is also proposed. Finally, an experiment is presented to validate the measurement and control strategy. The experimental results demonstrate that the proposed measurement and control strategy provides accurate angle motion with a root mean square (RMS) error of 0.21 μrad, which is approximately equal to the noise level. PMID:23860316

  5. Ultra-Precision Measurement and Control of Angle Motion in Piezo-Based Platforms Using Strain Gauge Sensors and a Robust Composite Controller

    Directory of Open Access Journals (Sweden)

    Zhi-Gang Wu

    2013-07-01

    Full Text Available The measurement and control strategy of a piezo-based platform by using strain gauge sensors (SGS and a robust composite controller is investigated in this paper. First, the experimental setup is constructed by using a piezo-based platform, SGS sensors, an AD5435 platform and two voltage amplifiers. Then, the measurement strategy to measure the tip/tilt angles accurately in the order of sub-μrad is presented. A comprehensive composite control strategy design to enhance the tracking accuracy with a novel driving principle is also proposed. Finally, an experiment is presented to validate the measurement and control strategy. The experimental results demonstrate that the proposed measurement and control strategy provides accurate angle motion with a root mean square (RMS error of 0.21 μrad, which is approximately equal to the noise level.

  6. Expression of the agmatine deiminase pathway in Enterococcus faecalis is activated by the AguR regulator and repressed by CcpA and PTS(Man systems.

    Directory of Open Access Journals (Sweden)

    Cristian Suárez

    Full Text Available Although the agmatine deiminase system (AgDI has been investigated in Enterococcus faecalis, little information is available with respect to its gene regulation. In this study we demonstrate that the presence of exogenous agmatine induces the expression of agu genes in this bacterium. In contrast to the homologous and extensively characterized AgDI system of S. mutants, the aguBDAC operon in E. faecalis is not induced in response to low pH. In spite of this, agmatine catabolism in this bacterium contributes by neutralizing the external medium while enhancing bacterial growth. Our results indicate that carbon catabolic repression (CCR operates on the AgDI system via a mechanism that involves interaction of CcpA and P-Ser-HPr with a cre site found in an unusual position considering the aguB promoter (55 nt upstream the +1 position. In addition, we found that components of the mannose phosphotransferase (PTS(Man system also contributed to CCR in E. faecalis since a complete relief of the PTS-sugars repressive effect was observed only in a PTS(Man and CcpA double defective strain. Our gene context analysis revealed that aguR is present in oral and gastrointestinal microorganisms. Thus, regulation of the aguBDAC operon in E. faecalis seems to have evolved to obtain energy and resist low pH conditions in order to persist and colonize gastrointestinal niches.

  7. Experimental characterization of a bi-dimensional array of negative capacitance piezo-patches for vibroacoustic control

    Science.gov (United States)

    Tateo, F.; Collet, M.; Ouisse, M.; Ichchou, M. N.; Cunefare, K. A.

    2013-04-01

    A recent technological revolution in the fields of integrated MEMS has finally rendered possible the mechanical integration of active smart materials, electronics and power supply systems for the next generation of smart composite structures. Using a bi-dimensional array of electromechanical transducers, composed by piezo-patches connected to a synthetic negative capacitance, it is possible to modify the dynamics of the underlying structure. In this study, we present an application of the Floquet-Bloch theorem for vibroacoustic power flow optimization, by means of distributed shunted piezoelectric material. In the context of periodically distributed damped 2D mechanical systems, this numerical approach allows one to compute the multi-modal waves dispersion curves into the entire first Brillouin zone. This approach also permits optimization of the piezoelectric shunting electrical impedance, which controls energy diffusion into the proposed semi-active distributed set of cells. Furthermore, we present experimental evidence that proves the effectiveness of the proposed control method. The experiment requires a rectangular metallic plate equipped with seventy-five piezo-patches, controlled independently by electronic circuits. More specifically, the out-of-plane displacements and the averaged kinetic energy of the controlled plate are compared in two different cases (open-circuit and controlled circuit). The resulting data clearly show how this proposed technique is able to damp and selectively reflect the incident waves.

  8. Role of ptsP, orfT, and sss recombinase genes in root colonization by Pseudomonas fluorescens Q8r1-96.

    Science.gov (United States)

    Mavrodi, Olga V; Mavrodi, Dmitri V; Weller, David M; Thomashow, Linda S

    2006-11-01

    Pseudomonas fluorescens Q8r1-96 produces 2,4-diacetylphloroglucinol (2,4-DAPG), a polyketide antibiotic that suppresses a wide variety of soilborne fungal pathogens, including Gaeumannomyces graminis var. tritici, which causes take-all disease of wheat. Strain Q8r1-96 is representative of the D-genotype of 2,4-DAPG producers, which are exceptional because of their ability to aggressively colonize and maintain large populations on the roots of host plants, including wheat, pea, and sugar beet. In this study, three genes, an sss recombinase gene, ptsP, and orfT, which are important in the interaction of Pseudomonas spp. with various hosts, were investigated to determine their contributions to the unusual colonization properties of strain Q8r1-96. The sss recombinase and ptsP genes influence global processes, including phenotypic plasticity and organic nitrogen utilization, respectively. The orfT gene contributes to the pathogenicity of Pseudomonas aeruginosa in plants and animals and is conserved among saprophytic rhizosphere pseudomonads, but its function is unknown. Clones containing these genes were identified in a Q8r1-96 genomic library, sequenced, and used to construct gene replacement mutants of Q8r1-96. Mutants were characterized to determine their 2,4-DAPG production, motility, fluorescence, colony morphology, exoprotease and hydrogen cyanide (HCN) production, carbon and nitrogen utilization, and ability to colonize the rhizosphere of wheat grown in natural soil. The ptsP mutant was impaired in wheat root colonization, whereas mutants with mutations in the sss recombinase gene and orfT were not. However, all three mutants were less competitive than wild-type P. fluorescens Q8r1-96 in the wheat rhizosphere when they were introduced into the soil by paired inoculation with the parental strain.

  9. On the application of reynolds theory to thermo-piezo-viscous lubrication in oil hydraulics

    DEFF Research Database (Denmark)

    Johansen, Per; Roemer, Daniel Beck; Andersen, Torben O.

    2015-01-01

    The efficiency of fluid power motors and pumps is a subject to research, which has generated numerous publications during the last three decades. The main incentives for this research are optimization of reliability and efficiency through the study of loss and wear mechanisms, which are very....... In this paper the derivation of Reynolds equation from the continuum assumption is reviewed and it is shown that the validity of Reynolds theory based pressure field solutions in oil hydraulic thermo-piezo-viscous lubrication models are subject to maximum bounds on the pressure and temperature field gradients...

  10. Quantitative Modeling of Coupled Piezo-Elastodynamic Behavior of Piezoelectric Actuators Bonded to an Elastic Medium for Structural Health Monitoring: A Review

    Directory of Open Access Journals (Sweden)

    Guoliang Huang

    2010-04-01

    Full Text Available Elastic waves, especially guided waves, generated by a piezoelectric actuator/sensor network, have shown great potential for on-line health monitoring of advanced aerospace, nuclear, and automotive structures in recent decades. Piezoelectric materials can function as both actuators and sensors in these applications due to wide bandwidth, quick response and low costs. One of the most fundamental issues surrounding the effective use of piezoelectric actuators is the quantitative evaluation of the resulting elastic wave propagation by considering the coupled piezo-elastodynamic behavior between the actuator and the host medium. Accurate characterization of the local interfacial stress distribution between the actuator and the host medium is the key issue for the problem. This paper presents a review of the development of analytical, numerical and hybrid approaches for modeling of the coupled piezo-elastodynamic behavior. The resulting elastic wave propagation for structural health monitoring is also summarized.

  11. Quantitative Modeling of Coupled Piezo-Elastodynamic Behavior of Piezoelectric Actuators Bonded to an Elastic Medium for Structural Health Monitoring: A Review

    Science.gov (United States)

    Huang, Guoliang; Song, Fei; Wang, Xiaodong

    2010-01-01

    Elastic waves, especially guided waves, generated by a piezoelectric actuator/sensor network, have shown great potential for on-line health monitoring of advanced aerospace, nuclear, and automotive structures in recent decades. Piezoelectric materials can function as both actuators and sensors in these applications due to wide bandwidth, quick response and low costs. One of the most fundamental issues surrounding the effective use of piezoelectric actuators is the quantitative evaluation of the resulting elastic wave propagation by considering the coupled piezo-elastodynamic behavior between the actuator and the host medium. Accurate characterization of the local interfacial stress distribution between the actuator and the host medium is the key issue for the problem. This paper presents a review of the development of analytical, numerical and hybrid approaches for modeling of the coupled piezo-elastodynamic behavior. The resulting elastic wave propagation for structural health monitoring is also summarized. PMID:22319319

  12. Topology optimization of piezo modal transducers with null-polarity phases

    DEFF Research Database (Denmark)

    Donoso, A.; Sigmund, O.

    2016-01-01

    Piezo modal transducers in 2d can be designed theoretically by tailoring polarity of the surface electrodes. However, it is also necessary to include null-polarity phases of known width separating areas of opposite polarity in the manufacturing process in order to avoid short-circuiting. Otherwise...... the performance of such devices could be spoiled. In this work, we propose an appropriate topology optimization interpolation function for the electrode profile such that the effect of this new phase (hereafter gap-phase) is included in the formulation of the design problem. The approach is density-based, where...... the interface is controlled by including the gradient norm in the electrode profile interpolation. Through a detailed case study in 1d, conclusions on how to control the width of this gap-phase are extracted, and subsequently extended to the 2d case....

  13. Enhancing Light Emission of ZnO-Nanofilm/Si-Micropillar Heterostructure Arrays by Piezo-Phototronic Effect.

    Science.gov (United States)

    Li, Xiaoyi; Chen, Mengxiao; Yu, Ruomeng; Zhang, Taiping; Song, Dongsheng; Liang, Renrong; Zhang, Qinglin; Cheng, Shaobo; Dong, Lin; Pan, Anlian; Wang, Zhong Lin; Zhu, Jing; Pan, Caofeng

    2015-06-22

    n-ZnO nanofilm/p-Si micropillar heterostructure light-emitting diode (LED) arrays for white light emissions are achieved and the light emission intensity of LED array is enhanced by 120% under -0.05% compressive strains. These results indicate a promising approach to fabricate Si-based light-emitting components with high performances enhanced by piezo-phototronic effect, with potential applications in touchpad technology, personalized signatures, smart skin, and silicon-based photonic integrated circuits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Characterization and Comparison of Control Units for Piezo Actuators to be used for Lorentz Force Compensation inth ILC

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, Sampriti; Pilipenko, Roman; /Fermilab

    2010-01-01

    Superconducting accelerators, such as the International Linear Collider (ILC), rely on very high Q accelerating cavities to achieve high electric fields at low RF power. Such cavities have very narrow resonances: a few kHz with a 1.3GHz resonance frequency for the ILC. Several mechanical factors cause tune shifts much larger than this: pressure variations in the liquid helium bath; microphonics from pumps and other mechanical devices; and for a pulsed machine such as the ILC, Lorentz force detuning (pressure from the contained RF field). Simple passive stiffening is limited by many manufacturing and material considerations. Therefore, active tuning using piezo actuators is needed. Here we study a supply for their operation. Since commercial power amplifiers are expensive, we analyzed the characteristics of four power amplifiers: (iPZD) built by Istituto Nazionale di Fisica Nucleare (Sezione di Pisa); and a DC-DC converter power supply built in Fermilab (Piezo Master); and two commercial amplifiers, Piezosystem jena and Piezomechanik. This paper presents an analysis and characterization of these amplifiers to understand the cost benefit and reliability when using in a large scale, pulsed beam accelerator like the ILC.

  15. Thermal hydraulic analyses of accidents associated with coolant leak from the primary circuit through a hole 10 mm equivalent diameter for the needs of PTS

    International Nuclear Information System (INIS)

    Krhounkova, J.; Kral, P.; Parduba, Z.

    1999-10-01

    The conservative assumptions of the analyses were oriented towards a worsening of the process with respect to the pressurized thermal shock (PTS). Four variants were treated, viz. leaks from the cold or hot leg, each at the rated power or zero power. Since the temperature of water supplied to the primary circuit by the emergency core cooling system is an important parameter with respect to a PTS, the calculations were performed by the iterative procedure: the basic thermal hydraulic calculation was performed by the RELAP5/MOD3.2.1 code which calculates the behaviour of the primary and secondary circuits, whereas the MELCOR code was used to calculate the behaviour of the parameters in the hermetic rooms. The calculation by the RELAP code was then repeated using data from the MELCOR calculations. Interventions by the reactor operators were also considered. (P.A.)

  16. Effect of the dilution factor on {sup 18}FDG and Na{sup 18}F samples for bacterial endotoxin test using PTS (portable test system)

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marina B.; Costa, Flavia M.; Ferreira, Soraya Z., E-mail: mbs@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    {sup 18}FDG and Na{sup 18}F are radiopharmaceuticals produced as sterile solutions suitable for intravenous administration, which must contain no more than 175 EV/V. The most commonly used approach to detect endotoxins is the gelclot technique that requires 60 minutes for results. For radiopharmaceuticals containing short-life radionuclides, such as {sup 18}F, there is an increasing interest for faster quality control methods. FDA licensed the Endosafe, PTS, a kinetic chromogenic endotoxin detection system that takes about 15 minutes for results. As other techniques, PTS test is susceptible to interferences which can be solved by product dilution. The aim of this study was to establish the best dilution of {sup 18}FDG and Na{sup 18}F for PTS analysis. Two different dilution factors for {sup 18}FDG and 1:10 for Na{sup 18}F were essayed: 1:10 and 1:100. {sup 18}FDG and Na{sup 18} solutions were prepared by the addition of LAL reagent water. Considering the assay acceptance criteria, the best dilution factor was 1:100 for {sup 18}FDG and 1:10 for Na{sup 18}F. The recovery of the product positive control was 98-12% for {sup 18}FDG 1:100 and 104-120% for Na{sup 18}F 1:10, which were, in both cases, within the specification (50-200%) and very close to 100%. Results obtained with these dilution studies were important to establish the most appropriate and non-interfering dilution factor for {sup 18}FDG and Na{sup 18}F routine endotoxin test. (author)

  17. Improved passive shunt vibration control of smart piezo-elastic beams using modal piezoelectric transducers with shaped electrodes

    International Nuclear Information System (INIS)

    Vasques, C M A

    2012-01-01

    Modal control and spatial filtering technologies for mitigation of vibration and/or structural acoustics radiation may be achieved through the use of distributed modal piezoelectric transducers with properly shaped electrodes. This approach filters out undesirable and uncontrollable modes over the bandwidth of interest in order to increase the robustness and stability of the controlled structural system, and may also yield higher values of the generalized modal electromechanical coupling coefficient, which is an important design parameter for achieving efficient passive shunt damping design. In this paper the improvements in passive shunt damping performance when using modal piezoelectric transducers with shaped electrodes are investigated for a two-layered resonant-shunted piezo-elastic smart beam structure. An electromechanical one-dimensional equivalent single-layer Euler–Bernoulli analytical model of two-layered smart piezo-elastic beams with arbitrary spatially shaped electrodes is established for modal and uniform electrode designs. The model is verified and validated by comparison with a one-dimensional discrete-layer (layerwise) finite element model, the damping performance of the shunted smart beam with shaped electrodes is investigated and assessed in terms of the generalized electromechanical coupling coefficient and frequency responses obtained when considering uniform and modally shaped electrodes and the underlying improved performance and advantages are assessed and discussed. (paper)

  18. Piezo Is Essential for Amiloride-Sensitive Stretch-Activated Mechanotransduction in Larval Drosophila Dorsal Bipolar Dendritic Sensory Neurons.

    Science.gov (United States)

    Suslak, Thomas J; Watson, Sonia; Thompson, Karen J; Shenton, Fiona C; Bewick, Guy S; Armstrong, J Douglas; Jarman, Andrew P

    2015-01-01

    Stretch-activated afferent neurons, such as those of mammalian muscle spindles, are essential for proprioception and motor co-ordination, but the underlying mechanisms of mechanotransduction are poorly understood. The dorsal bipolar dendritic (dbd) sensory neurons are putative stretch receptors in the Drosophila larval body wall. We have developed an in vivo protocol to obtain receptor potential recordings from intact dbd neurons in response to stretch. Receptor potential changes in dbd neurons in response to stretch showed a complex, dynamic profile with similar characteristics to those previously observed for mammalian muscle spindles. These profiles were reproduced by a general in silico model of stretch-activated neurons. This in silico model predicts an essential role for a mechanosensory cation channel (MSC) in all aspects of receptor potential generation. Using pharmacological and genetic techniques, we identified the mechanosensory channel, DmPiezo, in this functional role in dbd neurons, with TRPA1 playing a subsidiary role. We also show that rat muscle spindles exhibit a ruthenium red-sensitive current, but found no expression evidence to suggest that this corresponds to Piezo activity. In summary, we show that the dbd neuron is a stretch receptor and demonstrate that this neuron is a tractable model for investigating mechanisms of mechanotransduction.

  19. Dynamic characterization, monitoring and control of rotating flexible beam-mass structures via piezo-embedded techniques

    Science.gov (United States)

    Lai, Steven H.-Y.

    1992-01-01

    A variational principle and a finite element discretization technique were used to derive the dynamic equations for a high speed rotating flexible beam-mass system embedded with piezo-electric materials. The dynamic equation thus obtained allows the development of finite element models which accommodate both the original structural element and the piezoelectric element. The solutions of finite element models provide system dynamics needed to design a sensing system. The characterization of gyroscopic effect and damping capacity of smart rotating devices are addressed. Several simulation examples are presented to validate the analytical solution.

  20. High precision silicon piezo resistive SMART pressure sensor

    International Nuclear Information System (INIS)

    Brown, Rod

    2005-01-01

    Instruments for test and calibration require a pressure sensor that is precise and stable. Market forces also dictate a move away from single measurand test equipment and, certainly in the case of pressure, away from single range equipment. A pressure 'module' is required which excels in pressure measurement but is interchangble with sensors for other measurands. A communications interface for such a sensor has been specified. Instrument Digital Output Sensor (IDOS) that permits this interchanagability and allows the sensor to be inside or outside the measuring instrument. This paper covers the design and specification of a silicon diaphragm piezo resistive SMART sensor using this interface. A brief history of instrument sensors will be given to establish the background to this development. Design choices of the silicon doping, bridge energisation method, temperature sensing, signal conversion, data processing, compensation method, communications interface will be discussed. The physical format of the 'in-instrument' version will be shown and then extended to the packaging design for the external version. Test results will show the accuracy achieved exceeds the target of 0.01%FS over a range of temperatures

  1. High precision silicon piezo resistive SMART pressure sensor

    Science.gov (United States)

    Brown, Rod

    2005-01-01

    Instruments for test and calibration require a pressure sensor that is precise and stable. Market forces also dictate a move away from single measurand test equipment and, certainly in the case of pressure, away from single range equipment. A pressure `module' is required which excels in pressure measurement but is interchangble with sensors for other measurands. A communications interface for such a sensor has been specified. Instrument Digital Output Sensor (IDOS) that permits this interchanagability and allows the sensor to be inside or outside the measuring instrument. This paper covers the design and specification of a silicon diaphragm piezo resistive SMART sensor using this interface. A brief history of instrument sensors will be given to establish the background to this development. Design choices of the silicon doping, bridge energisation method, temperature sensing, signal conversion, data processing, compensation method, communications interface will be discussed. The physical format of the `in-instrument' version will be shown and then extended to the packaging design for the external version. Test results will show the accuracy achieved exceeds the target of 0.01%FS over a range of temperatures.

  2. Synbiotic impact of tagatose on viability of Lactobacillus rhamnosus strain GG mediated by the phosphotransferase system (PTS).

    Science.gov (United States)

    Koh, Ji Hoon; Choi, Seung Hye; Park, Seung Won; Choi, Nag-Jin; Kim, Younghoon; Kim, Sae Hun

    2013-10-01

    Synbiotics, the combination of prebiotics and probiotics, has been shown to produce synergistic effects that promote gastrointestinal well-being of host. Tagatose is a low calorie food ingredient with putative health-promoting benefits. Herein, we investigated its synbiotic impact on the viability of Lactobacillus casei 01 and Lactobacillus rhamnosus strain GG and the potential mechanism involved. Tagatose, as a synbiotic substrate, enhanced the growth of L. casei 01 and L. rhamnosus strain GG compared to other prebiotics. Other gut-indigenous such as Clostridium spp. readily utilized fructooligosaccharide (FOS), the most widely used functional prebiotics, but not tagatose. Additionally, tagatose enhanced probiotic functions of L. casei 01 and L. rhamnosus strain GG by reinforcing their attachment on HT-29 intestine epithelial cells and enhancing their cholesterol-lowering activities. Whole transcriptome study and quantitative real-time polymerase chain reaction (qRT-PCR) test showed that the presence of tagatose in L. rhamnosus strain GG caused induction of a large number of genes associated with carbohydrate metabolism including the phosphotransferase system (PTS). Collectively, these results indicate the tagatose enhanced the growth of L. casei 01 and L. rhamnosus strain GG and their probiotic activities by activating tagatose-associated PTS networks. Importantly, this study highlights the potential application of tagatose and L. casei 01 and/or L. rhamnosus strain GG as a synbiotic partner in functional dairy foods (i.e. yogurt and cheese) and therapeutic dietary supplements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Actuation control of a PiezoMEMS biomimetic robotic jellyfish

    Science.gov (United States)

    Alejandre, Alvaro; Olszewski, Oskar; Jackson, Nathan

    2017-06-01

    Biomimetic micro-robots try to mimic the motion of a living system in the form of a synthetically developed microfabricated device. Dynamic motion of living systems have evolved through the years, but trying to mimic these motions is challenging. Micro-robotics are particular challenging as the fabrication of devices and controlling the motion in 3 dimensions is difficult. However, micro-scale robotics have potential to be used in a wide range of applications. MEMS based robots that can move and function in a liquid environment is of particular interest. This paper describes the development of a piezoMEMS based device that mimics the movement of a jellyfish. The paper focuses on the development of a finite element model that investigates a method of controlling the individual piezoelectric beams in order to create a jet propulsion motion, consisting of a quick excitation pulse followed by a slow recovery pulse in order to maximize thrust and velocity. By controlling the individual beams or legs of the jellyfish robot the authors can control the robot to move precisely in 3 dimensions.

  4. Enhancing Photoresponsivity of Self-Aligned MoS2 Field-Effect Transistors by Piezo-Phototronic Effect from GaN Nanowires.

    Science.gov (United States)

    Liu, Xingqiang; Yang, Xiaonian; Gao, Guoyun; Yang, Zhenyu; Liu, Haitao; Li, Qiang; Lou, Zheng; Shen, Guozhen; Liao, Lei; Pan, Caofeng; Lin Wang, Zhong

    2016-08-23

    We report high-performance self-aligned MoS2 field-effect transistors (FETs) with enhanced photoresponsivity by the piezo-phototronic effect. The FETs are fabricated based on monolayer MoS2 with a piezoelectric GaN nanowire (NW) as the local gate, and a self-aligned process is employed to define the source/drain electrodes. The fabrication method allows the preservation of the intrinsic property of MoS2 and suppresses the scattering center density in the MoS2/GaN interface, which results in high electrical and photoelectric performances. MoS2 FETs with channel lengths of ∼200 nm have been fabricated with a small subthreshold slope of 64 mV/dec. The photoresponsivity is 443.3 A·W(-1), with a fast response and recovery time of ∼5 ms under 550 nm light illumination. When strain is introduced into the GaN NW, the photoresponsivity is further enhanced to 734.5 A·W(-1) and maintains consistent response and recovery time, which is comparable with that of the mechanical exfoliation of MoS2 transistors. The approach presented here opens an avenue to high-performance top-gated piezo-enhanced MoS2 photodetectors.

  5. A new piezo-driven microgripper based on the double-rocker mechanism

    International Nuclear Information System (INIS)

    Yang, Yi-ling; Wei, Yan-ding; Tian, Geng; Zhao, Xiao-wei; Fu, Lei; Lou, Jun-qiang

    2015-01-01

    This paper reports the design and modelling of a new piezo-driven microgripper with large output displacements. The design of the microgripper is based on the double-rocker mechanism and the parallelogram mechanism. The microgripper can produce a large output displacement and a parallel movement of the gripper tips. Theoretical models for the microgripper are derived using the pseudorigid-body-model method. Through several finite-element analysis simulations, the optimal geometric parameters of the microgripper are obtained, and the theoretical models are evaluated and verified. The performance of the proposed microgripper is demonstrated by several experiments, and a micromanipulation case is presented. The experimental results indicate that the microgripper with the double-rocker mechanism has a large output displacement of 213.9 μm and a large amplification ratio of 21.4. The microgripper is capable of multiscale micromanipulation. (paper)

  6. Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands.

    Science.gov (United States)

    Lin, Yin-Yan; Wu, Hau-Tieng; Hsu, Chi-An; Huang, Po-Chiun; Huang, Yuan-Hao; Lo, Yu-Lun

    2016-12-07

    Physiologically, the thoracic (THO) and abdominal (ABD) movement signals, captured using wearable piezo-electric bands, provide information about various types of apnea, including central sleep apnea (CSA) and obstructive sleep apnea (OSA). However, the use of piezo-electric wearables in detecting sleep apnea events has been seldom explored in the literature. This study explored the possibility of identifying sleep apnea events, including OSA and CSA, by solely analyzing one or both the THO and ABD signals. An adaptive non-harmonic model was introduced to model the THO and ABD signals, which allows us to design features for sleep apnea events. To confirm the suitability of the extracted features, a support vector machine was applied to classify three categories - normal and hypopnea, OSA, and CSA. According to a database of 34 subjects, the overall classification accuracies were on average 75.9%±11.7% and 73.8%±4.4%, respectively, based on the cross validation. When the features determined from the THO and ABD signals were combined, the overall classification accuracy became 81.8%±9.4%. These features were applied for designing a state machine for online apnea event detection. Two event-byevent accuracy indices, S and I, were proposed for evaluating the performance of the state machine. For the same database, the S index was 84.01%±9.06%, and the I index was 77.21%±19.01%. The results indicate the considerable potential of applying the proposed algorithm to clinical examinations for both screening and homecare purposes.

  7. Piezo-Phototronic Effect on Selective Electron or Hole Transport through Depletion Region of Vis-NIR Broadband Photodiode.

    Science.gov (United States)

    Zou, Haiyang; Li, Xiaogan; Peng, Wenbo; Wu, Wenzhuo; Yu, Ruomeng; Wu, Changsheng; Ding, Wenbo; Hu, Fei; Liu, Ruiyuan; Zi, Yunlong; Wang, Zhong Lin

    2017-08-01

    Silicon underpins nearly all microelectronics today and will continue to do so for some decades to come. However, for silicon photonics, the indirect band gap of silicon and lack of adjustability severely limit its use in applications such as broadband photodiodes. Here, a high-performance p-Si/n-ZnO broadband photodiode working in a wide wavelength range from visible to near-infrared light with high sensitivity, fast response, and good stability is reported. The absorption of near-infrared wavelength light is significantly enhanced due to the nanostructured/textured top surface. The general performance of the broadband photodiodes can be further improved by the piezo-phototronic effect. The enhancement of responsivity can reach a maximum of 78% to 442 nm illumination, the linearity and saturation limit to 1060 nm light are also significantly increased by applying external strains. The photodiode is illuminated with different wavelength lights to selectively choose the photogenerated charge carriers (either electrons or holes) passing through the depletion region, to investigate the piezo-phototronic effect on electron or hole transport separately for the first time. This is essential for studying the basic principles in order to develop a full understanding about piezotronics and it also enables the development of the better performance of optoelectronics. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A Self-Powered Wearable Noninvasive Electronic-Skin for Perspiration Analysis Based on Piezo-Biosensing Unit Matrix of Enzyme/ZnO Nanoarrays.

    Science.gov (United States)

    Han, Wuxiao; He, Haoxuan; Zhang, Linlin; Dong, Chuanyi; Zeng, Hui; Dai, Yitong; Xing, Lili; Zhang, Yan; Xue, Xinyu

    2017-09-06

    The emerging multifunctional flexible electronic-skin for establishing body-electric interaction can enable real-time monitoring of personal health status as a new personalized medicine technique. A key difficulty in the device design is the flexible power supply. Here a self-powered wearable noninvasive electronic-skin for perspiration analysis has been realized on the basis of a piezo-biosensing unit matrix of enzyme/ZnO nanoarrays. The electronic-skin can detect lactate, glucose, uric acid, and urea in the perspiration, and no outside electrical power supply or battery is used in the biosensing process. The piezoelectric impulse of the piezo-biosensing units serves as the power supply and the data biosensor. The working mechanism can be ascribed to the piezoelectric-enzymatic-reaction coupling effect of enzyme/ZnO nanowires. The electronic-skin can real-time/continuously monitor the physiological state of a runner through analyzing the perspiration on his skin. This approach can promote the development of a new-type of body electric and self-powered biosensing electronic-skin.

  9. Physical properties and the Peierls instability of Li0.82[Pt(S2C2(CN)2)2] · 2H2O

    DEFF Research Database (Denmark)

    Ahmad, M. M.; Turner, D. J.; Underhill, A. E.

    1984-01-01

    The infrared reflectivity, the temperature-dependent conductivity, and thermopower of the one-dimensional conductor Li0.82[Pt(S2C2(CN)2)2] · 2H2O, LiPt(mnt), is presented. It undergoes a simple Peierls transition at Tc=215 K, which is not influenced by correlations or by cation ordering. The meta...

  10. Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation

    Science.gov (United States)

    Simon, Donald L.; Garg, Sanjay

    2011-01-01

    An emerging approach in the field of aircraft engine controls and system health management is the inclusion of real-time, onboard models for the inflight estimation of engine performance variations. This technology, typically based on Kalman-filter concepts, enables the estimation of unmeasured engine performance parameters that can be directly utilized by controls, prognostics, and health-management applications. A challenge that complicates this practice is the fact that an aircraft engine s performance is affected by its level of degradation, generally described in terms of unmeasurable health parameters such as efficiencies and flow capacities related to each major engine module. Through Kalman-filter-based estimation techniques, the level of engine performance degradation can be estimated, given that there are at least as many sensors as health parameters to be estimated. However, in an aircraft engine, the number of sensors available is typically less than the number of health parameters, presenting an under-determined estimation problem. A common approach to address this shortcoming is to estimate a subset of the health parameters, referred to as model tuning parameters. The problem/objective is to optimally select the model tuning parameters to minimize Kalman-filterbased estimation error. A tuner selection technique has been developed that specifically addresses the under-determined estimation problem, where there are more unknown parameters than available sensor measurements. A systematic approach is applied to produce a model tuning parameter vector of appropriate dimension to enable estimation by a Kalman filter, while minimizing the estimation error in the parameters of interest. Tuning parameter selection is performed using a multi-variable iterative search routine that seeks to minimize the theoretical mean-squared estimation error of the Kalman filter. This approach can significantly reduce the error in onboard aircraft engine parameter estimation

  11. Piezo-phototronic Effect Enhanced UV/Visible Photodetector Based on Fully Wide Band Gap Type-II ZnO/ZnS Core/Shell Nanowire Array.

    Science.gov (United States)

    Rai, Satish C; Wang, Kai; Ding, Yong; Marmon, Jason K; Bhatt, Manish; Zhang, Yong; Zhou, Weilie; Wang, Zhong Lin

    2015-06-23

    A high-performance broad band UV/visible photodetector has been successfully fabricated on a fully wide bandgap ZnO/ZnS type-II heterojunction core/shell nanowire array. The device can detect photons with energies significantly smaller (2.2 eV) than the band gap of ZnO (3.2 eV) and ZnS (3.7 eV), which is mainly attributed to spatially indirect type-II transition facilitated by the abrupt interface between the ZnO core and ZnS shell. The performance of the device was further enhanced through the piezo-phototronic effect induced lowering of the barrier height to allow charge carrier transport across the ZnO/ZnS interface, resulting in three orders of relative responsivity change measured at three different excitation wavelengths (385, 465, and 520 nm). This work demonstrates a prototype UV/visible photodetector based on the truly wide band gap semiconducting 3D core/shell nanowire array with enhanced performance through the piezo-phototronic effect.

  12. Structural identification and damage diagnosis using self-sensing piezo-impedance transducers

    Science.gov (United States)

    Lim, Yee Yan; Bhalla, Suresh; Kiong Soh, Chee

    2006-08-01

    The use of smart materials, such as lead zirconate titanate (PZT), has accelerated developments in the fields of structural identification and automated structural health monitoring (SHM). One such technique that has made much progress is the electro-mechanical impedance (EMI) technique, which employs self-sensing piezo-impedance transducers. In this technique, a PZT patch is surface bonded to the structure to be monitored and its corresponding electro-mechanical admittance signature is used for damage detection. This paper introduces a new method for identifying structures from the measured admittance signatures in terms of equivalent structural parameters, whereby the identified parameters are used for damage characterization. The new method has been applied to a truss, a beam and a concrete cube, and found to be able to successfully perform structural identification and damage diagnosis. In addition, several advantages have been ascertained in comparison with the conventional, non-parametric statistical methods.

  13. Mechanism of phosphoryl transfer and protein-protein interaction in the PTS system-an NMR study

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopal, P.; Klevit, R.E. [Univ. of Washington, Seattle, WA (United States)

    1994-12-01

    HPr and Enzyme IIA{sup Glc} are two of the components of the bacterial PTS (phosphoenolpyruvate: sugar phosphotranferase system) and are involved in the phosphorylation and concomitant translocation of sugars across the membrane. These PTS protein complexes also regulate sugar transport. HPr, phosphorylated at a histidine N1 site by Enzyme I and phosphoenol pyruvate, transfers the phosphoryl group to a histidine N3 position in Enzyme IIA{sup Glc}. HPrs from Gram-positive bacteria undergo regulatory phosphorylation at Ser{sup 46}, whereby phosphorylation of the histidine residue is inhibited. Conversely, histidine phosphorylation inhibits phosphorylation at Ser{sup 46}. HPrs from Gram-negative bacteria possess a serine residue at position 46, but do not undergo regulatory phosphorylation. HPr forms an open-faced sandwich structure with a four-strand S-sheet and 2 to 3 helices lying on top of the sheet. The active-site histidine and Ser{sup 46} occur in conformationally flexible regions. P-His-HPr from the Gram-positive bacterium Bacillus subtilus has been investigated by both homonuclear and heteronuclear two-dimensional and three-dimensional NMR experiments using an in-situ enzymatic regeneration system to maintain a constant level of P-His-HPr. The results show that localized conformational changes occur in the vicinity of the active-site histidine and also near Ser{sup 46}. HPr-Enzyme IIA{sup Glc} complexes from both Bacillus subtilis and Gram-negative Escherichia coli were also studied by a variety of {sup 15}N-edited two-dimensional NMR experiments, which were performed on uniformly {sup 15}N-labeled HPr complexed to unlabeled Enzyme IIA{sup Glc}. The complex is in fast exchange with a molecular weight of about 27 kDa. The focus of our work is to assess the changes undergone by HPr (the smaller of the two components), and so all the experiments were performed with excess Enzyme IIA present in the system.

  14. Fabrication of self supporting metallic rare earth targets using a piezo-electric quartz as substrate

    International Nuclear Information System (INIS)

    Bonetti, C.P.

    1975-01-01

    Metallic self-supporting targets of cerium and praseodymium of 1 to 2.5mg/cm 2 on a diameter of 18mm were made using the process of evaporation by electron bombardment. Materials are placed on a piezo-electric quartz which permits the direct and precise measurement of the mass of the deposit. Then, such a deposit must be removed and placed on a frame in an environment of argon gas. This method is important because it can be used for small quantities of materials (case of separated isotopes). These high purity foils are used for the study of (d,n) reactions with the Tandem Van de Graaff Accelerator [fr

  15. Piezo-optic and elasto-optic properties of monoclinic triglycine sulfate crystals.

    Science.gov (United States)

    Mytsyk, Bogdan; Demyanyshyn, Natalya; Erba, Alessandro; Shut, Viktor; Mozzharov, Sergey; Kost, Yaroslav; Mys, Oksana; Vlokh, Rostyslav

    2017-12-01

    For the first time, to the best of our knowledge, we have experimentally determined all of the components of the piezo-optic tensor for monoclinic crystals. This has been implemented on a specific example of triglycine sulfate crystals. Based on the results obtained, the complete elasto-optic tensor has been calculated. Acousto-optic figures of merit (AOFMs) have been estimated for the case of acousto-optic interaction occurring in the principal planes of the optical indicatrix ellipsoid and for geometries in which the highest elasto-optic coefficients are involved as effective parameters. It has been found that the highest AOFM value is equal to 6.8×10 -15   s 3 /kg for the case of isotropic acousto-optic interaction with quasi-longitudinal acoustic waves in the principal planes. This AOFM is higher than the corresponding values typical for canonic acousto-optic materials, which are transparent in the deep ultraviolet spectral range.

  16. Acousto-optic modulation and opto-acoustic gating in piezo-optomechanical circuits

    Science.gov (United States)

    Balram, Krishna C.; Davanço, Marcelo I.; Ilic, B. Robert; Kyhm, Ji-Hoon; Song, Jin Dong; Srinivasan, Kartik

    2017-01-01

    Acoustic wave devices provide a promising chip-scale platform for efficiently coupling radio frequency (RF) and optical fields. Here, we use an integrated piezo-optomechanical circuit platform that exploits both the piezoelectric and photoelastic coupling mechanisms to link 2.4 GHz RF waves to 194 THz (1550 nm) optical waves, through coupling to propagating and localized 2.4 GHz acoustic waves. We demonstrate acousto-optic modulation, resonant in both the optical and mechanical domains, in which waveforms encoded on the RF carrier are mapped to the optical field. We also show opto-acoustic gating, in which the application of modulated optical pulses interferometrically gates the transmission of propagating acoustic pulses. The time-domain characteristics of this system under both pulsed RF and pulsed optical excitation are considered in the context of the different physical pathways involved in driving the acoustic waves, and modelled through the coupled mode equations of cavity optomechanics. PMID:28580373

  17. Synthesis and Physicochemical Characterization of D-Tagatose-1-phosphate: The Substrate of the Tagatose-1-Phosphate Kinase TagK in the PTS-mediated D-Tagatose Catabolic Pathway of Bacillus licheniformis

    Science.gov (United States)

    Van der Heiden, Edwige; Delmarcelle, Michaël; Simon, Patricia; Counson, Melody; Galleni, Moreno; Freedberg, Darón I.; Thompson, John; Joris, Bernard; Battistel, Marcos D.

    2015-01-01

    We report the first enzymatic synthesis of D-tagatose-1-phosphate (Tag-1P) by the multi-component PEP-dependent:tag-PTS present in tagatose-grown cells of Klebsiella pneumoniae. Physicochemical characterization by 31P and 1H NMR spectroscopy reveals that, in solution, this derivative is primarily in the pyranose form. Tag-1P was used to characterize the putative tagatose-1-phosphate kinase (TagK) of the Bacillus licheniformis PTS-mediated D-Tagatose catabolic Pathway (Bli-TagP). For this purpose, a soluble protein fusion was obtained with the 6 His-tagged trigger factor (TFHis6) of Escherichia coli. The active fusion enzyme was named TagK-TFHis6. Tag-1P and D-fructose-1-phosphate (Fru-1P) are substrates for the TagK-TFHis6 enzyme, whereas the isomeric derivatives D-tagatose-6-phosphate (Tag-6P) and D-fructose-6-phosphate (Fru-6P) are inhibitors. Studies of catalytic efficiency (kcat/Km) reveal that the enzyme specificity is markedly in favor of Tag-1P as substrate. Importantly, we show in vivo that the transfer of the phosphate moiety from PEP to the B. licheniformis tagatose-specific enzyme II (EIITag) in E.coli is inefficient. The capability of the PTS general cytoplasmic components of B. subtilis, HPr and EI, to restore the phosphate transfer is demonstrated. PMID:26159072

  18. Improving Delay-Margin of Noncollocated Vibration Control of Piezo-Actuated Flexible Beams via a Fractional-Order Controller

    Directory of Open Access Journals (Sweden)

    Teerawat Sangpet

    2014-01-01

    Full Text Available Noncollocated control of flexible structures results in nonminimum-phase systems because the separation between the actuator and the sensor creates an input-output delay. The delay can deteriorate stability of closed-loop systems. This paper presents a simple approach to improve the delay-margin of the noncollocated vibration control of piezo-actuated flexible beams using a fractional-order controller. Results of real life experiments illustrate efficiency of the controller and show that the fractional-order controller has better stability robustness than the integer-order controller.

  19. Interpenetrated Uranyl-Organic Frameworks with bor and pts Topology: Structure, Spectroscopy, and Computation.

    Science.gov (United States)

    Liu, Chao; Chen, Fang-Yuan; Tian, Hong-Rui; Ai, Jing; Yang, Weiting; Pan, Qing-Jiang; Sun, Zhong-Ming

    2017-11-20

    Two novel three-dimensional interpenetrated uranyl-organic frameworks, (NH 4 ) 4 [(UO 2 ) 4 (L 1 ) 3 ]·6H 2 O (1) and [(UO 2 ) 2 (H 2 O) 2 L 2 ]·2H 2 O (2), where L 1 = tetrakis(3-carboxyphenyl)silicon and L 2 = tetrakis(4-carboxyphenyl)silicon, were synthesized by a combination of two isomeric tetrahedral silicon-centered ligands with 3-connected triangular [(UO 2 )(COO) 3 ] - and 4-connected dinuclear [(UO 2 ) 2 (COO) 4 ] units, respectively. Structural analyses indicate that 1 possesses a 2-fold interpenetrating anion bor network, while 2 exhibits a 3-fold interpenetrated 4,4-connected neutral network with pts topology. Both compounds were characterized by thermogravimetric analysis and IR, UV-vis, and photoluminescence spectroscopy. A relativistic density functional theory (DFT) investigation on 10 model compounds of 1 and 2 shows good agreement of the structural parameters, stretching vibrational frequencies, and absorption with experimental results; the time-dependent DFT calculations unravel that low-energy absorption bands originate from ligand-to-uranium charge transfer.

  20. A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

    Science.gov (United States)

    Heverly, Matthew; Dougherty, Sean; Toon, Geoffrey; Soto, Alejandro; Blavier, Jean-Francois

    2004-01-01

    One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

  1. Single-Crystalline cooperite (PtS): Crystal-Chemical characterization, ESR spectroscopy, and {sup 195}Pt NMR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rozhdestvina, V. I., E-mail: veronika@ascnet.ru; Ivanov, A. V.; Zaremba, M. A. [Far East Division, Russian Academy of Sciences, Institute of Geology and Nature Management (Russian Federation); Antsutkin, O. N.; Forsling, W. [Lulea University of Technology (Sweden)

    2008-05-15

    Single-crystalline cooperite (PtS) with a nearly stoichiometric composition was characterized in detail by X-ray diffraction, electron-probe X-ray microanalysis, and high-resolution scanning electron microscopy. For the first time it was demonstrated that {sup 195}Pt static and MAS NMR spectroscopy can be used for studying natural platinum minerals. The {sup 195}Pt chemical-shift tensor of cooperite was found to be consistent with the axial symmetry and is characterized by the following principal values: {delta}{sub xx} = -5920 ppm, {delta}{sub yy} = -3734 ppm, {delta}{sub zz} = +4023 ppm, and {delta}{sub iso} = -1850 ppm. According to the ESR data, the samples of cooperite contain copper(II), which is adsorbed on the surface during the layer-by-layer crystal growth and is not involved in the crystal lattice.

  2. SMILE: experimental results of the WP4 PTS large scale test performed on a component in terms of cracked cylinder involving warm pre-stress

    International Nuclear Information System (INIS)

    Kerkhof, K.; Bezdikian, G.; Moinereau, D.; Dahl, A; Wadier, Y.; Gilles, P.; Keim, E.; Chapuliot, S.; Taylor, N.; Lidbury, D.; Sharples, J.; Budden, P.; Siegele, D.; Nagel, G.; Bass, R.; Emond, D.

    2005-01-01

    The Reactor Pressure Vessel (RPV) is an essential component, which is liable to limit the lifetime duration of PWR plants. The assessment of defects in RPV subjected to pressurized thermal shock (PTS) transients made at an European level generally does not necessarily consider the beneficial effect of the load history (Warm Pre-stress, WPS). The SMILE project - Structural Margin Improvements in aged embrittled RPV with Load history Effects-aims to give sufficient elements to demonstrate, to model and to validate the beneficial WPS effect. It also aims to harmonize the different approaches in the national codes and standards regarding the inclusion of the WPS effect in a RPV structural integrity assessment. The project includes significant experimental work on WPS type experiments with C(T) specimens and a PTS type transient experiment on a large component. This paper deals with the results of the PTS type transient experiment on a component-like specimen subjected to WPS- loading, the so called Validation Test, carried out within the framework of work package WP4. The test specimen consists of a cylindrical thick walled specimen with a thickness of 40 mm and an outer diameter of 160 mm, provided with an internal fully circumferential crack with a depth of about 15 mm. The specified load path type is Load-Cool-Unload-Fracture (LCUF). No crack initiation occurred during cooling (thermal shock loading) although the loading path crossed the fracture toughness curve in the transition region. The benefit of the WPS-effect by final re-loading up to fracture in the lower shelf region, was shown clearly. The corresponding fracture load during reloading in the lower shelf region was significantly higher than the crack initiation values of the original material in the lower shelf region. The post test fractographic evaluation showed that the fracture mode was predominantly cleavage fracture also with some secondary cracks emanating from major crack. (authors)

  3. FEM Analysis of Beam-coupling Impedance and RF Contacts Criticality on the LHC UA9 Piezo Goniometer

    CERN Document Server

    Danisi, A; Passarelli, A; Masi, A; Losito, R; Salvant, B

    2014-01-01

    The UA9 piezo-goniometer has been designed to guarantee micro-radians-accuracy angular positioning of a silicon crystal for a crystal collimation experiment in the LHC, and to minimize the impact on the LHC beam coupling impedance. This paper presents a Finite Element Method (FEM) study of the device, in both parking and operational positions, to evaluate its impact on the LHC impedance budget. In addition, the shielding contribution of the RF gaskets has been carefully evaluated, with the objective to assess the consequences for operation in case of their failure. A final word is drawn on the overall device impedance criticality.

  4. Electron beam position stabilization with a piezo-electric optical correction system

    CERN Document Server

    Averett, T; McKeown, R D; Pitt, M

    1999-01-01

    A piezo-electrically controlled optical correction system was successfully used to reduce the helicity-correlated pulse-to-pulse position differences of a laser spot to better than +-100 nm at a pulse rate of 600 Hz. Using a simple feedback algorithm, average position differences of DELTA x-bar=-3.5+-4.2 nm and DELTA y-bar=2.6+-6.6 nm were obtained over a 6 h period. This optical correction system was successfully used in the polarized electron source at the Bates Linear Accelerator Center to stabilize the position of the electron beam during the recent SAMPLE experiment. Because this experiment measures a parity violating signal at the 10 sup - sup 6 level, it is sensitive to systematic effects which are correlated with the helicity of the incident electrons. One potentially large systematic effect is the helicity-correlated motion of the incident electron beam. By using this optical correction system, electron beam position differences at the location of the experiment were routinely kept well below +-100 n...

  5. A Study on the Optimal Actuation Structure Design of a Direct Needle-Driven Piezo Injector for a CRDi Engine

    Directory of Open Access Journals (Sweden)

    Sangik Han

    2017-03-01

    Full Text Available Recently, the high-pressure fuel injection performance of common-rail direct injection (CRDi engines has become more important, due to the need to improve the multi-injection strategy. A multiple injection strategy provides better emission and fuel economy characteristics than a normal single injection scheme. The CRDi engine performance changes with the type of high-pressure electro-mechanical injector that is used and its injection response in a multi-injection scheme. In this study, a direct needle-driven piezo injector (DPI was investigated, to optimize its actuation components, including the plate length, number of springs, and the elasticity of the spring between the injector needle and the piezo stack. Three prototype DPIs were proposed by this research. They were classified as Type 1, 2, and 3, depending on whether the injector needle was hydraulic or mechanical. Then, the optimal prototype was determined by conducting four evaluation experiments analyzing the maximum injection pressure, injection rate, spray visualization, and real engine combustion application. As a result, it was found that the Type 3 DPI prototype, with several pan-springs and plates, had the highest injection pressure, a steady injection rate, and the fastest spray speed. It also demonstrated the most effective emission reduction for a two-stage rapid spray injection in a single-cylinder CRDi engine. The Type 3 DPI displays an increased elasticity from its hydraulic needle that provides a synergy effect for improving DPI actuation.

  6. Thermal hydraulic evaluation for an experimental facility to investigate pressurized thermal shock (PTS) in CDTN/CNEN; Avaliacao termo-hidraulica da montagem experimental de choque termico pressurizado do CDTN/CNEN

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, Elcio T.; Navarro, Moyses A.; Aronne, Ivam D.; Terra, Jose L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    2002-07-01

    The goal of the work presented in this paper is to provide necessary thermal hydraulics information to the design of an experimental installation to investigate the Pressurized Thermal Shock (PTS) to be implemented at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN). The envisaged installation has a test section that represents, in a small scale, a pressure vessel of a nuclear reactor. This test section will be heated and then exposed to a PTS in order to evaluate the appearance and development of cracks. To verify the behavior of the temperatures of the pressure vessel after a sudden flood through the annulus, calculations were made using the RELAP5/MOD 3.2.2 gamma code. Different outer radiuses were studied for the annular region. The results showed that the smaller annulus spacing (20 mm) anticipates the wetting of the surface and produces a higher cooling of the external surface, which stays completely wet for a longer time. (author)

  7. Strain-Modulated Bandgap and Piezo-Resistive Effect in Black Phosphorus Field-Effect Transistors.

    Science.gov (United States)

    Zhang, Zuocheng; Li, Likai; Horng, Jason; Wang, Nai Zhou; Yang, Fangyuan; Yu, Yijun; Zhang, Yu; Chen, Guorui; Watanabe, Kenji; Taniguchi, Takashi; Chen, Xian Hui; Wang, Feng; Zhang, Yuanbo

    2017-10-11

    Energy bandgap largely determines the optical and electronic properties of a semiconductor. Variable bandgap therefore makes versatile functionality possible in a single material. In layered material black phosphorus, the bandgap can be modulated by the number of layers; as a result, few-layer black phosphorus has discrete bandgap values that are relevant for optoelectronic applications in the spectral range from red, in monolayer, to mid-infrared in the bulk limit. Here, we further demonstrate continuous bandgap modulation by mechanical strain applied through flexible substrates. The strain-modulated bandgap significantly alters the density of thermally activated carriers; we for the first time observe a large piezo-resistive effect in black phosphorus field-effect transistors (FETs) at room temperature. The effect opens up opportunities for future development of electromechanical transducers based on black phosphorus, and we demonstrate an ultrasensitive strain gauge constructed from black phosphorus thin crystals.

  8. Piezo-Catalytic Effect on the Enhancement of the Ultra-High Degradation Activity in the Dark by Single- and Few-Layers MoS2 Nanoflowers.

    Science.gov (United States)

    Wu, Jyh Ming; Chang, Wei En; Chang, Yu Ting; Chang, Chih-Kai

    2016-05-01

    Single- and few-layer MoS2 nanoflowers are first discovered to have a piezo-catalyst effect, exhibiting an ultra-high degradation activity in the dark by introducing external mechanical strains. The degradation ratio of the Rhodamine-B dye solution reaches 93% within 60 s under ultrasonic-wave assistance in the dark. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Accumulation of chlorinated and brominated persistent toxic substances (PTS) and their relationship to testosterone suppression in Norway rats from Japan

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K. [Shimadzu Techno-Research Inc. (Japan); Ishizuka, M.; Fujita, S. [Graduate School of Veterinary Medicine, Hokkaido Univ. (Japan); Tanikawa, R. [Inst. of Tech., Ikari Corp. (Japan)

    2004-09-15

    Contamination of chlorinated/brominated persistent toxic substances (PTS) such as polychlorinated, -dibenzo-p-dioxins (PCDDs), -dibenzofurans (PCDFs), -biphenyls (PCBs), - organochlorine pesticides (OCPs) {l_brace}e.g., aldrin, dieldrin, endrin, chlordane compounds [cis/transchlordane, cis/trans-nonachlor, oxychlordane, heptachlor, heptachlor epoxide], hexachlorobenzene (HCB), 2,2-bis(p-chlorophenyl)-1,1,1-trichloroethane (DDTs) and its metabolities [o,p/p,p'-DDD and DDE] and hexachlorocyclohexane (HCHs){r_brace} and -brominated diphenyl ethers (PBDEs) are considered to important class of chemicals due to persistence in nature, bioaccumulation potential and adverse health effects in wildlife and humans. Among South East Asian countries, Japan reported to contaminated with aforesaid chemicals with considerable amounts. There is no document reports contamination of PTS in wild animals, which in-habit near humans. Norway rat (NR) inhabits not only near human environment but also distributed worldwide. Especially, NR feeds on human waste and shelter in and around human environment and thus exposure of toxic contaminants in this animal considered to similar with those in humans. In addition, rats have unique physiology that match with humans (e.g., they have similar pathogens as humans have). Therefore, analysis of toxic contaminants in NR considered as indirect measure in humans. Considering those facts, in this study, we analyzed NR collected from urban area, rural area, waste dumping or land fill site and isolated remote island from Japan. Particularly several chlorinated and brominated organic contaminants such as PCDDs, PCDFs, PCBs, DDTs, HCHs, chlordane compounds, heptachlor, heptachlor epoxide, HCB, aldrin, dieldrin, endrin and PBDEs were analyzed in rat livers by isotope dilution technique using HRGC-HRMS. In addition, laboratory Wistar rats (WR) were used as control.

  10. Optimal Design of Silicon-based Chips for Piezo-induced Ultrasound Resonances in Embedded Microchannels

    DEFF Research Database (Denmark)

    Garofalo, F.; Laurell, T.; Bruus, Henrik

    2015-01-01

    constituting the device (the piezo transducer, the silicon walls, the fluid-filled microchannel, and the glass lid) allows for the introduction of the weak formulation used in the finite element discretization of the equations describing the system in its oscillatory regime. Additionally, the knowledge...... of the Lagrangian density leads to the derivation of the correct structure of the Hamiltonian density, i.e. the energy density, which is important for the quantification of the energy content of the whole system and its individual parts. Specifically, the energy content of the embedded microchannel is quantified...... by means of the acoustofluidic yield η defined as the ratio between the energy in the channel and the total energy. From the standpoint of acoustophoretic application, the introduction of the acoustophoretic mean orientation allows us to identify the frequencies for which an acoustophoretic effect, i...

  11. Coherent coupling between radio frequency, optical, and acoustic waves in piezo-optomechanical circuits

    Science.gov (United States)

    Balram, Krishna C.; Davanço, Marcelo I.; Song, Jin Dong; Srinivasan, Kartik

    2016-01-01

    Optomechanical cavities have been studied for applications ranging from sensing to quantum information science. Here, we develop a platform for nanoscale cavity optomechanical circuits in which optomechanical cavities supporting co-localized 1550 nm photons and 2.4 GHz phonons are combined with photonic and phononic waveguides. Working in GaAs facilitates manipulation of the localized mechanical mode either with a radio frequency (RF) field through the piezo-electric effect, which produces acoustic waves that are routed and coupled to the optomechanical cavity by phononic crystal waveguides, or optically through the strong photoelastic effect. Along with mechanical state preparation and sensitive readout, we use this to demonstrate an acoustic wave interference effect, similar to atomic coherent population trapping, in which RF-driven coherent mechanical motion is cancelled by optically-driven motion. Manipulating cavity optomechanical systems with equal facility through both photonic and phononic channels enables new architectures for signal transduction between the optical, electrical, and mechanical domains. PMID:27446234

  12. Test of piezo-ceramic motor technology in ITER relevant high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Monti, Chiara, E-mail: chiara.monti@enea.it [Associazione EURATOM-ENEA sulla Fusione, via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Besi Vetrella, Ugo; Mugnaini, Giampiero; Neri, Carlo; Rossi, Paolo; Viola, Rosario [Associazione EURATOM-ENEA sulla Fusione, via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Dubus, Gregory; Damiani, Carlo [Fusion for Energy, c/ Josep Pla, 2 Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2014-10-15

    In the framework of a Fusion for Energy (F4E) grant, a test campaign started in 2012 in order to assess the performance of the in-vessel viewing system (IVVS) probe concept and to verify its compatibility when exposed to ITER typical working conditions. ENEA laboratories went through with several tests simulating high magnetic fields, high temperature, high vacuum, gamma radiation and neutron radiation. A customized motor has been adopted to study the performances of ultrasonic piezo motors technology in high magnetic field conditions. This paper reports on the testing activity performed on the motor in a multi Tesla magnetic field. The job was carried out in a test facility of ENEA laboratories able to achieve 14 T. A maximum field of 10 T, fully compliant with ITER requirements (8 T), was applied. A specific mechanical assembly has been designed and manufactured to hold the motor in the region with high homogeneity of the field. Results obtained so far indicate that the motor is compatible with high magnetic fields, and are presented in the paper.

  13. Finite Element Modelling and Analysis of Damage Detection Methodology in Piezo Electric Sensor and Actuator Integrated Sandwich Cantilever Beam

    Science.gov (United States)

    Pradeep, K. R.; Thomas, A. M.; Basker, V. T.

    2018-03-01

    Structural health monitoring (SHM) is an essential component of futuristic civil, mechanical and aerospace structures. It detects the damages in system or give warning about the degradation of structure by evaluating performance parameters. This is achieved by the integration of sensors and actuators into the structure. Study of damage detection process in piezoelectric sensor and actuator integrated sandwich cantilever beam is carried out in this paper. Possible skin-core debond at the root of the cantilever beam is simulated and compared with undamaged case. The beam is actuated using piezoelectric actuators and performance differences are evaluated using Polyvinylidene fluoride (PVDF) sensors. The methodology utilized is the voltage/strain response of the damaged versus undamaged beam against transient actuation. Finite element model of piezo-beam is simulated in ANSYSTM using 8 noded coupled field element, with nodal degrees of freedoms are translations in the x, y directions and voltage. An aluminium sandwich beam with a length of 800mm, thickness of core 22.86mm and thickness of skin 0.3mm is considered. Skin-core debond is simulated in the model as unmerged nodes. Reduction in the fundamental frequency of the damaged beam is found to be negligible. But the voltage response of the PVDF sensor under transient excitation shows significantly visible change indicating the debond. Piezo electric based damage detection system is an effective tool for the damage detection of aerospace and civil structural system having inaccessible/critical locations and enables online monitoring possibilities as the power requirement is minimal.

  14. Optimization and test of a digital radio-frequency control system and developments for the EPICS-based accelerator control system at the S-DALINAC

    International Nuclear Information System (INIS)

    Burandt, Christoph Warwick

    2017-01-01

    The first part of this thesis covers multiple extensions of the digital low-level radio-frequency control system of the electron accelerator S-DALINAC. This comprises bringing into regular operation the piezoelectrically driven fine tuners of the superconducting cavities. For this a power supply series has been developed, which is compatible with the existing electronics and can power the piezo elements. Furthermore the flexibility of the radio-frequency control system has been demonstrated on superconducting quarter-wave-resonators of the ion accelerator ALPI. These 160 MHz cavities are quite different to the S-DALINAC's acceleration structures but could be operated successfully with low residual errors in phase and amplitude nevertheless. The second part describes the migration of the accelerator control system to an EPICS-based system. A multitude of devices with a diversity of interfaces and protocols have been integrated and higher-level functionality has been unified. Within the framework of the construction of the third recirculation beam-line, the beam-path-length adjustment mechanism was motorized.

  15. Optimization and test of a digital radio-frequency control system and developments for the EPICS-based accelerator control system at the S-DALINAC; Optimierung und Test der digitalen Hochfrequenzregelung und Entwicklung fuer das EPICS-basierte Beschleunigungskontrollsystem am S-DALINAC

    Energy Technology Data Exchange (ETDEWEB)

    Burandt, Christoph Warwick

    2017-07-01

    The first part of this thesis covers multiple extensions of the digital low-level radio-frequency control system of the electron accelerator S-DALINAC. This comprises bringing into regular operation the piezoelectrically driven fine tuners of the superconducting cavities. For this a power supply series has been developed, which is compatible with the existing electronics and can power the piezo elements. Furthermore the flexibility of the radio-frequency control system has been demonstrated on superconducting quarter-wave-resonators of the ion accelerator ALPI. These 160 MHz cavities are quite different to the S-DALINAC's acceleration structures but could be operated successfully with low residual errors in phase and amplitude nevertheless. The second part describes the migration of the accelerator control system to an EPICS-based system. A multitude of devices with a diversity of interfaces and protocols have been integrated and higher-level functionality has been unified. Within the framework of the construction of the third recirculation beam-line, the beam-path-length adjustment mechanism was motorized.

  16. Development of a viscoplastic dynamic fracture mechanics treatment for crack arrest predictions in a PTS event

    International Nuclear Information System (INIS)

    Kanninen, M.F.; Hudak, S.J. Jr.; Reed, K.W.; Dexter, R.J.; Polch, E.Z.; Cardinal, J.W.; Achenbach, J.D.; Popelar, C.H.

    1986-01-01

    The objective of this research is to develop a fundamentally correct methodology for the prediction of crack arrest at the high upper shelf conditions occurring in a postulated pressurized thermal shock (PTS) event. The effort is aimed at the development of a versatile finite-element method for the solution of time-dependent boundary value problems that admit inertia effects, a prescribed spatial temperature distribution, and viscoplastic constitutive and fracture behavior. Supporting this development are (1) material characterization and fracture experimentation, (2) detailed mathematical analyses of the near-tip region, (3) elastodynamic fracture analysis, and (4) elastic-plastic tearing instability analyses. As a first step, dynamic-viscoplastic analyses are currently being made of the wide plate tests being performed by the National Bureau of Standards in a companion HSST program. Some preliminary conclusions drawn from this work and from the supporting research activities are offered in this paper. The outstanding critical issues that subsequent research must focus on are also described

  17. Size-dependent free vibration and dynamic analyses of piezo-electro-magnetic sandwich nanoplates resting on viscoelastic foundation

    Science.gov (United States)

    Arefi, Mohammad; Zenkour, Ashraf M.

    2017-09-01

    In this paper, size-dependent free vibration analysis of a sandwich nanoplate is presented. The sandwich nanoplate is including an elastic nano core and two piezo-electro-magnetic face-sheets as sensor and actuator actuated by electric and magnetic potentials. The sandwich nanoplate is resting on visco-Pasternak's foundation. Hamilton's principle is employed to derive the governing equations of motion based on Kirchhoff plate and nonlocal elasticity theory. The numerical results are presented to study the influence of important parameters of the problem such as applied electric and magnetic potentials, nonlocal parameter and visco-Pasternak's parameters. Furthermore, the influence of various boundary conditions is discussed on the vibration characteristics of the sandwich nanoplate.

  18. Review of thermal-hydraulic calculations for Calvert Cliffs and H.B. Robinson PTS study

    International Nuclear Information System (INIS)

    Jo, J.H.; Yuelys-Miksis, C.; Rohatgi, U.S.

    1984-01-01

    Thermal-hydraulic transient calculations performed by LANL using the TRAC-PF1 code and by INEL using the RELAP5 code for the USNRC pressurized thermal shock (PTS) study of the Calvert Cliffs and H.B. Robinson Nuclear Power Plants have been reviewed at BNL including the input decks and steady state calculations. Furthermore, six transients for each plant have been selected for the in-depth review. Simple hand calculations based on the mass and energy balances of the entire reactor system, have been performed to predict the temperature and pressure of the reactor system, and the results have been compared with those obtained by the code calculation. In general, the temperatures and pressures of the primary system calculated by the codes have been very reasonable. The secondary pressures calculated by TRAC appear to indicate that the codes have some difficulty with the condensation model and further work is needed to assess the code calculation of the U-tube steam generator pressure when the cold auxiliary feedwater is introduced to the steam generator. However, it is not expected that this uncertainty would affect the transient calculations significantly

  19. Future technology of the spark-ignition engine: spray-guided direct injection with piezo injector; Die Zukunftstechnologie des Ottomotors: Strahlgefuehrte Direkteinspritzung mit Piezo-Injektor

    Energy Technology Data Exchange (ETDEWEB)

    Waltner, A.; Lueckert, P.; Schaupp, U.; Rau, E.; Kemmler, R.; Weller, R. [DaimlerChrysler AG, Stuttgart (Germany)

    2006-07-01

    The completely new-style second-generation direct-injection for spark-ignition engines from Mercedes-Benz offers clear improvements in fuel consumption, power and emission levels. Faced with the necessity of further reducing fuel consumption, primarily in spark-ignition engines, the Mercedes-Benz combustion system represents a significant leap in technology. It was possible to noticeably expand the mapping range in which stratified operation can be used compared with the first generation. This significant improvement in efficiency results in more useable energy and a substantial reduction in consumption in city traffic, and also on cross-country and highway trips at roughly constant speeds. These benefits make themselves felt not only in the test cycle, but also in the real-world consumption achieved by the customer. Development proceeded from the base aspirated engine on the principle of the modular expansion of technology. Since production development of this combustion system was not possible using the hydraulic and ignition components available on the market, a new outward-opening piezo fuel injector had to be developed for production readiness, along with a 200-bar high-pressure fuel system, which is being introduced here for the first time world-wide. The injection spray stability and excellent mixture preparation that it achieves produce an optimally combustible mixture at the spark plug. The potential of multiple injection, along with stability in stratified operation, brings further benefits and possibilities for direct injection in fuel consumption and emissions. (orig.)

  20. Viscoplastic-dynamic analyses of small-scale fracture tests to obtain crack arrest toughness values for PTS conditions

    International Nuclear Information System (INIS)

    Kanninen, M.F.; Hudak, S.J. Jr; Dexter, R.J.; Couque, H.; O'Donoghue, P.E.; Polch, E.Z.

    1988-01-01

    Reliable predictions of crack arrest at the high upper shelf toughness conditions involved in postulated pressurized thermal shock (PTS) events require procedures beyond those utilized in conventional fracture mechanics treatments. To develop such a procedure, viscoplastic-dynamic fracture mechanics finite element analyses, viscoplastic material characterization testing, and small-scale crack propagation and arrest experimentation are being combines in this research. The approach couples SwRI's viscoplastic-dynamic fracture mechanics finite element code VISCRK with experiments using duplex 4340/A533B steel compact specimens. The experiments are simulated by VISCRK computations employing the Bodner-Partom viscoplastic constitutive relation and the nonlinear fracture mechanics parameter T. The goal is to develop temperature-dependent crack arrest toughness values for A533B steel. While only room temperature K Ia values have been obtained so far, these have been found to agree closely with those obtained from wide plate tests. (author)

  1. Characterization and optimization of an ultrasonic piezo-optical ring sensor

    International Nuclear Information System (INIS)

    Frankforter, Erik; Lin, Bin; Giurgiutiu, Victor

    2016-01-01

    A resonant piezo-optical ring sensor with both piezoelectric and fiber Bragg grating (FBG) sensing elements was assessed for ultrasonic wave detection. The ring sensor is an existing device that has been shown experimentally to exhibit a number of sensing features: omnidirectionality, mode selectivity, and frequency tunability. The present study uses finite element modeling to understand these features as a means to characterize and optimize the sensor. A combined vibration-wave propagation modeling approach was used, where the vibrational modeling provided a basis for understanding sensing features, and the wave propagation modeling provided predictive power for sensor performance. The sensor features corresponded to the fundamental vibrational mode of the sensor, particularly to the base motion of this mode. The vibrational modeling was also used to guide sensor optimization, with an emphasis on the FBG and piezoelectric sensing elements. It was found that sensor symmetry and nodes of extraneous resonance modes could be exploited to provide a single-resonance response. A series of pitch-catch guided wave experiments were performed on a thin aluminum plate to assess the optimized sensor configuration. Tuning curves showed a single-frequency response to a Lamb wave and mechanical filtering away from the dominant frequency; the sensor capability for mechanical amplification of a Lamb wave and mechanical amplification of a pencil-lead-break acoustic emission event were also demonstrated. (paper)

  2. High-resolution dynamic pressure sensor array based on piezo-phototronic effect tuned photoluminescence imaging.

    Science.gov (United States)

    Peng, Mingzeng; Li, Zhou; Liu, Caihong; Zheng, Qiang; Shi, Xieqing; Song, Ming; Zhang, Yang; Du, Shiyu; Zhai, Junyi; Wang, Zhong Lin

    2015-03-24

    A high-resolution dynamic tactile/pressure display is indispensable to the comprehensive perception of force/mechanical stimulations such as electronic skin, biomechanical imaging/analysis, or personalized signatures. Here, we present a dynamic pressure sensor array based on pressure/strain tuned photoluminescence imaging without the need for electricity. Each sensor is a nanopillar that consists of InGaN/GaN multiple quantum wells. Its photoluminescence intensity can be modulated dramatically and linearly by small strain (0-0.15%) owing to the piezo-phototronic effect. The sensor array has a high pixel density of 6350 dpi and exceptional small standard deviation of photoluminescence. High-quality tactile/pressure sensing distribution can be real-time recorded by parallel photoluminescence imaging without any cross-talk. The sensor array can be inexpensively fabricated over large areas by semiconductor product lines. The proposed dynamic all-optical pressure imaging with excellent resolution, high sensitivity, good uniformity, and ultrafast response time offers a suitable way for smart sensing, micro/nano-opto-electromechanical systems.

  3. Use of a piezo-electric quartz as substrate for the preparation of self-supporting rare earth targets, in metallic form, not oxidized

    International Nuclear Information System (INIS)

    Bonetti, C.

    1975-01-01

    A technique for preparing rare earth self-supporting targets is described. These high purity foils are used for nuclear spectroscopy, with a tandem Van de Graaff accelerator. Target thicknesses range from 1000μg/cm 2 to 2500μg/cm 2 . The originality of this procedure consists in using the piezo-electric quartz for target thickness measurements and for temporary substrate. With this method, it is possible to measure the target thickness without geometrical errors and to suppress the effects of the molecular flux anisotropy. (Auth.)

  4. Study on Temperature and Synthetic Compensation of Piezo-Resistive Differential Pressure Sensors by Coupled Simulated Annealing and Simplex Optimized Kernel Extreme Learning Machine.

    Science.gov (United States)

    Li, Ji; Hu, Guoqing; Zhou, Yonghong; Zou, Chong; Peng, Wei; Alam Sm, Jahangir

    2017-04-19

    As a high performance-cost ratio solution for differential pressure measurement, piezo-resistive differential pressure sensors are widely used in engineering processes. However, their performance is severely affected by the environmental temperature and the static pressure applied to them. In order to modify the non-linear measuring characteristics of the piezo-resistive differential pressure sensor, compensation actions should synthetically consider these two aspects. Advantages such as nonlinear approximation capability, highly desirable generalization ability and computational efficiency make the kernel extreme learning machine (KELM) a practical approach for this critical task. Since the KELM model is intrinsically sensitive to the regularization parameter and the kernel parameter, a searching scheme combining the coupled simulated annealing (CSA) algorithm and the Nelder-Mead simplex algorithm is adopted to find an optimal KLEM parameter set. A calibration experiment at different working pressure levels was conducted within the temperature range to assess the proposed method. In comparison with other compensation models such as the back-propagation neural network (BP), radius basis neural network (RBF), particle swarm optimization optimized support vector machine (PSO-SVM), particle swarm optimization optimized least squares support vector machine (PSO-LSSVM) and extreme learning machine (ELM), the compensation results show that the presented compensation algorithm exhibits a more satisfactory performance with respect to temperature compensation and synthetic compensation problems.

  5. Influence of the spray characteristics of a piezo-A-nozzle on the inflammation at spray guided combustion processes; Einfluss der Spraycharakteristik einer Piezo-A-Duese auf die Entflammung beim strahlgefuehrten Brennverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Breuninger, Tobias; Schmidt, Juergen [Magdeburg Univ. (DE). Inst. fuer Stroemungstechnik und Thermodynamik (ISUT); Hese, Martin; Tschoeke, Helmut [Magdeburg Univ. (DE). Inst. fuer Mobile Systeme (IMS); Kufferath, Andreas [Robert Bosch GmbH, Schwieberdingen (Germany); Altenschmidt, Frank [Daimler AG, Stuttgart (Germany)

    2011-07-01

    The spray-guided combustion process offers a significant potential for improvement on the fuel consumption in partial-load engine operation. Due to the very close positioning of the injector to the spark plug, there is only very little time for the fuel mixture generation which leads to the presence of still liquid fuel particles next to already evaporized one. Furthermore the fuel-mixture generation is primarily driven by the dynamics of the fuel spray. In this article the spray characteristics of a Piezo-A-injector under pressure-chamber conditions as well as the combustion behavior on a one-cylinder test motor are analyzed. The global spray dispersion is analyzed using high-speed visualization while laser-optical measurements are used to observe the ignition-area. The mean diameter as well as the velocity of fuel droplets are determined using the phase-doppler-anemometry (PDA). An extinction-measuring methodology is used to quantify the liquid fuel particles. Analyzing the evaluated misfire-rate as a function of the spray-attributes allows for rating the spray-sections according to their ignition behavior. (orig.)

  6. CFD use in PTS safety analysis state of art and challenges for industrial applications

    International Nuclear Information System (INIS)

    Martin, Alain; Cornille, Sebastien; Lestang, Frederic; Bellet, Serge; Barbier, Anthony; Vit, Carole; Huvelin, Fabien

    2009-01-01

    For the Reactor Pressure Vessel (RPV) assessment and lifetime evaluation of the nuclear plants, French Utility applies a series of calculations including thermal-hydraulic, thermo mechanical and fracture mechanics studies in order to study the Pressurized Thermal Shock (PTS) in the downcomer caused by the safety injection. Within the frame of the plant life time project, integrity assessments of the French 900 MWe (3-loops) series RPV have been performed. We found that the modeling of thermal-hydraulics loads is a source of gain. Considering the length of local 3D calculation and the large number of cases, EDF and AREVA-NP decided to share the effort. From a physical phenomena point of view, the results of the system code analysis (CATHARE computation) of the PTS transient induce two kinds of scenarios: single phase and two-phase flows in the cold leg. For single phase flow, the two chains of software differ: EDF uses Code Saturne (coupled with the thermal solid code SYRTHES) and AREVA-NP uses STAR CD for thermal hydraulic computation. According to this approach, comparison between the two chains of tools has been performed. Moreover this action contributes to the verification and the validation of each code in accordance with the OECD Best Practice Guidelines (BPG). The study has been achieved by two independent teams from EDF and AREVA-NP. It should be emphasized that this benchmark helped to strengthen the accuracy of CFD and the adapted methodology (working progress). The good agreement observed between the different results and their accordance with the validation computations confirms the validity of the approach. In the case where the cold legs are partially filled with steam, it becomes a two-phase problem and new important effects occur. Thus, an advanced prediction of RPV thermal loading during these transients requires sophisticated two-phase, local scale, 3D codes. In that purpose, a program has been set up to extend the capabilities of the NEPTUNE CFD

  7. A Magnetorestrictive Tuning System for Particle Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Chiu-Ying Tai; Jordan Cormier; William Espinola; Zhixiu Han; Chad Joshi; Anil Mavanur; Livia Racz; Kenneth Shepard; Edward Daly; Kirk Davis

    2005-05-16

    Energen, Inc. has designed, built, and demonstrated several fast and slow tuners based on its magnetostrictive actuators and stepper motor. These tuners are designed for Superconducting Radio Frequency (SRF) cavities, which are important structures in particle accelerators that support a wide spectrum of disciplines, including nuclear and high-energy physics and free electron lasers (FEL). In the past two years, Energen's work has focused on magnetostrictive fast tuners for microphonics and Lorentz detuning compensation on elliptical-cell and spoke-loaded cavities. These tuners were custom designed to meet specific requirements, which included a few to 100 micron stroke range, hundreds to kilohertz operation frequency, and cryogenic temperature operation in vacuum or liquid helium. These tuners have been tested in house and at different laboratories, such as DESY, Argonne National Lab, and Jefferson Lab. Some recent results are presented in this paper.

  8. The nociception genes painless and Piezo are required for the cellular immune response of Drosophila larvae to wasp parasitization.

    Science.gov (United States)

    Tokusumi, Yumiko; Tokusumi, Tsuyoshi; Schulz, Robert A

    2017-05-13

    In vertebrates, interaction between the nervous system and immune system is important to protect a challenged host from stress inputs from external sources. In this study, we demonstrate that sensory neurons are involved in the cellular immune response elicited by wasp infestation of Drosophila larvae. Multidendritic class IV neurons sense contacts from external stimuli and induce avoidance behaviors for host defense. Our findings show that inactivation of these sensory neurons impairs the cellular response against wasp parasitization. We also demonstrate that the nociception genes encoding the mechanosensory receptors Painless and Piezo, both expressed in class IV neurons, are essential for the normal cellular immune response to parasite challenge. Copyright © 2017. Published by Elsevier Inc.

  9. Modulation of persistent magnetoresistance by piezo-strain effect in manganite-based heterostructures

    Science.gov (United States)

    Li, W.; Yan, H.; Chai, X. J.; Wang, S. H.; Dong, X. L.; Ren, L. X.; Chen, C. L.; Jin, K. X.

    2017-05-01

    Persistent magnetoresistance effects in the phase-separated Pr0.65(Ca0.25Sr0.75)0.35MnO3/SrTiO3 and Pr0.65(Ca0.25Sr0.75)0.35MnO3/0.7PbMg1/3Nb2/3O3-0.3PbTiO3 heterostructures under a low magnetic field are investigated. It is observed that the persistent magnetoresistance effects decrease with increasing temperatures and the values for the heterostructures on 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 and SrTiO3 substrates are about 86.6% and 33.2% at 40 K, respectively. More interestingly, the applied electric field on the 0.7PbMg1/3Nb2/3O3-0.3PbTiO3 substrate can suppress the persistent magnetoresistance effect, indicating that different energy landscapes can be dramatically modulated by the piezo-strain. These results are discussed in terms of the strain-induced competition in the ferromagnetic state and the charge-ordering phase by the energy scenario, which provide a promising approach for designing devices of electric-magnetic memories in all-oxide heterostructures.

  10. A Magnetostrictive Tuning System for Particle Accelerators

    CERN Document Server

    Tai, Chiu-Ying; Daly, Edward; Davis, Kirk; Espinola, William; Han, Zhixiu; Joshi, Chandrashekhar; Mavanur, Anil; Racz, Livia; Shepard, Kenneth

    2005-01-01

    Energen, Inc. has designed, built, and demonstrated several fast and slow tuners based on its magnetostrictive actuators and stepper motor. These tuners are designed for Superconducting Radio Frequency (SRF) cavities, which are important structures in particle accelerators that support a wide spectrum of disciplines, including nuclear and high-energy physics and free electron lasers (FEL). In the past two years, Energen's work has focused on magnetostrictive fast tuners for microphonics and Lorentz detuning compensation on elliptical-cell and spoke-loaded cavities, including the capability for real-time closed-loop control. These tuners were custom designed to meet specific requirements, which included a few to 100 micron stroke range, hundreds to kilohertz operation frequency, and cryogenic temperature operation in vacuum or liquid helium. These tuners have been tested in house and at different laboratories, such as DESY, Argonne National Lab, and Jefferson Lab. Some recent results are presented in this pape...

  11. Self-powered vision electronic-skin basing on piezo-photodetecting Ppy/PVDF pixel-patterned matrix for mimicking vision

    Science.gov (United States)

    Han, Wuxiao; Zhang, Linlin; He, Haoxuan; Liu, Hongmin; Xing, Lili; Xue, Xinyu

    2018-06-01

    The development of multifunctional electronic-skin that establishes human-machine interfaces, enhances perception abilities or has other distinct biomedical applications is the key to the realization of artificial intelligence. In this paper, a new self-powered (battery-free) flexible vision electronic-skin has been realized from pixel-patterned matrix of piezo-photodetecting PVDF/Ppy film. The electronic-skin under applied deformation can actively output piezoelectric voltage, and the outputting signal can be significantly influenced by UV illumination. The piezoelectric output can act as both the photodetecting signal and electricity power. The reliability is demonstrated over 200 light on–off cycles. The sensing unit matrix of 6 × 6 pixels on the electronic-skin can realize image recognition through mapping multi-point UV stimuli. This self-powered vision electronic-skin that simply mimics human retina may have potential application in vision substitution.

  12. Self-powered vision electronic-skin basing on piezo-photodetecting Ppy/PVDF pixel-patterned matrix for mimicking vision.

    Science.gov (United States)

    Han, Wuxiao; Zhang, Linlin; He, Haoxuan; Liu, Hongmin; Xing, Lili; Xue, Xinyu

    2018-06-22

    The development of multifunctional electronic-skin that establishes human-machine interfaces, enhances perception abilities or has other distinct biomedical applications is the key to the realization of artificial intelligence. In this paper, a new self-powered (battery-free) flexible vision electronic-skin has been realized from pixel-patterned matrix of piezo-photodetecting PVDF/Ppy film. The electronic-skin under applied deformation can actively output piezoelectric voltage, and the outputting signal can be significantly influenced by UV illumination. The piezoelectric output can act as both the photodetecting signal and electricity power. The reliability is demonstrated over 200 light on-off cycles. The sensing unit matrix of 6 × 6 pixels on the electronic-skin can realize image recognition through mapping multi-point UV stimuli. This self-powered vision electronic-skin that simply mimics human retina may have potential application in vision substitution.

  13. Patient guided Piezo-electric Extracorporeal Shockwave Therapy as treatment for chronic severe patellar tendinopathy: A pilot study.

    Science.gov (United States)

    Zwerver, Johannes; Dekker, Femke; Pepping, Gert-Jan

    2010-01-01

    Patellar tendinopathy is a common overuse injury for which no evidence-based treatment guidelines exist. Extracorporeal Shock Wave Therapy (ESWT) seems to be an effective treatment for patellar tendinopathy but the most beneficial treatment strategies still need to be ascertained. Aim of this pilot study was to investigate if patient guided Piezo-electric, focused ESWT, without local anesthesia is a safe and well tolerated treatment which improves pain and function in patients with patellar tendinopathy. Nineteen male athletes with severe chronic patellar tendinopathy received 3 patient guided focused medium to high energy ESWT treatments at a weekly interval. Before and after 3 months VISA-P and VAS (pain) scores were recorded. Data on side effects and complications of treatment were also collected. No serious complications were reported and patients tolerated the treatment well. Mean VISA-P score improved from 36.1 to 50.1 (p patellar tendinopathy.

  14. Growth and characterization of Pb(Lu{sub 1/2}Nb{sub 1/2})O{sub 3}-Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-PbTiO{sub 3} ternary piezo-/ferroelectric crystals

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ying [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); College of Physics and Energy, Fujian Normal University, Fuzhou, Fujian 350117 (China); He, Chao [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Yang, Xiaoming [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); College of Physics and Energy, Fujian Normal University, Fuzhou, Fujian 350117 (China); Li, Xiuzhi; Wang, Zujian [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Huang, Zhigao; Lai, Fachun [College of Physics and Energy, Fujian Normal University, Fuzhou, Fujian 350117 (China); Long, Xifa, E-mail: lxf@fjirsm.ac.cn [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China)

    2016-08-05

    Piezo-/ferroelectric crystals of Pb(Lu{sub 1/2}Nb{sub 1/2})O{sub 3}-Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-PbTiO{sub 3} ternary solid solution system with high Curie temperature, in the vicinity of morphotropic phase boundary (MPB) region, are grown by the top-seeded solution growth (TSSG) method for the first time. The compositions and structures of the crystals are analyzed, all the structures are found to have pure perovskite structure using X-ray diffraction analysis. Di-/piezo-/ferroelectric properties of the crystals are also characterized systematically. The Curie temperature T{sub c} and coercive field E{sub c}, increase gradually with increasing PbTiO{sub 3} content. In particular, the crystal with composition 0.34PLN-0.31PMN-0.35PT possesses excellent electric properties including the Curie temperature, the rhombohedral–tetragonal phase transition temperature, the piezoelectric coefficient, the remnant polarization and the coercive field, which are T{sub c} = 228 °C, T{sub RT} = 156 °C, d{sub 33} = 2092 pC N{sup −1}, Pr = 35.5 μC cm{sup −2} and E{sub c} = 8.1 kV cm{sup −1}, respectively, making it a promising material for transducers or detectors in a wide temperature range. - Highlights: • PLN-PMN-PT Piezo-/ferroelectric crystals are grown by TSSG method. • The Curie temperature and coercive field increase gradually with increasing PT. • The crystal of 0.34PLN-0.31PMN-0.35PT possesses excellent electric properties.

  15. [Atraumatic bone expansion: Interest of piezo-surgery, conicals expanders and immediate implantation combination].

    Science.gov (United States)

    Iraqui, O; Lakhssassi, N; Berrada, S; Merzouk, N

    2016-06-01

    The durability of dental implants depends on the presence of a 1mm coating bone sheath all around the fixture. Therefore, bone resorption represents a challenge for the practitioner. Bone expansion is a surgical technique that allows the management of horizontal bone atrophy. Cortical bone splitting allows for an enlargement of the residual crest by displacement of the vestibular bone flap. The immediate placement of implants secures the widening and allows for a 97% survival rate. However, bone expansion is hard to undertake in sites with high bone density. Furthermore, the use of traditional instruments increases patient's stress and the risk for an interruptive fracture during bone displacement. Non-traumatic bone expansion is one solution to this problem. The combination of piezo-surgery and conical expanders allows for a secured displacement of the selected bone flap as well as an immediate implant placement, avoiding the risk of slipping, overheating, or fracture, all within an undeniable operative comfort. Non-traumatic bone expansion is a reliable, reproducible, conservative, and economical in time and cost procedure. We describe our atraumatic bone expension and immediate implant placement technique in high bone density sites and illustrate it by a clinical case. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Enhanced production of electron cyclotron resonance plasma by exciting selective microwave mode on a large-bore electron cyclotron resonance ion source with permanent magnet.

    Science.gov (United States)

    Kimura, Daiju; Kurisu, Yosuke; Nozaki, Dai; Yano, Keisuke; Imai, Youta; Kumakura, Sho; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2014-02-01

    We are constructing a tandem type ECRIS. The first stage is large-bore with cylindrically comb-shaped magnet. We optimize the ion beam current and ion saturation current by a mobile plate tuner. They change by the position of the plate tuner for 2.45 GHz, 11-13 GHz, and multi-frequencies. The peak positions of them are close to the position where the microwave mode forms standing wave between the plate tuner and the extractor. The absorbed powers are estimated for each mode. We show a new guiding principle, which the number of efficient microwave mode should be selected to fit to that of multipole of the comb-shaped magnets. We obtained the excitation of the selective modes using new mobile plate tuner to enhance ECR efficiency.

  17. Enhanced production of electron cyclotron resonance plasma by exciting selective microwave mode on a large-bore electron cyclotron resonance ion source with permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Daiju, E-mail: kimura@nf.eie.eng.osaka-u.ac.jp; Kurisu, Yosuke; Nozaki, Dai; Yano, Keisuke; Imai, Youta; Kumakura, Sho; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2014-02-15

    We are constructing a tandem type ECRIS. The first stage is large-bore with cylindrically comb-shaped magnet. We optimize the ion beam current and ion saturation current by a mobile plate tuner. They change by the position of the plate tuner for 2.45 GHz, 11–13 GHz, and multi-frequencies. The peak positions of them are close to the position where the microwave mode forms standing wave between the plate tuner and the extractor. The absorbed powers are estimated for each mode. We show a new guiding principle, which the number of efficient microwave mode should be selected to fit to that of multipole of the comb-shaped magnets. We obtained the excitation of the selective modes using new mobile plate tuner to enhance ECR efficiency.

  18. High-precision piezo-ejection ocular microdosing: Phase II study on local and systemic effects of topical phenylephrine.

    Science.gov (United States)

    Ianchulev, Tsontcho; Weinreb, Robert; Tsai, James C; Lin, Shan; Pasquale, Louis R

    2018-01-01

    Conventional eyedropper-delivered volumes (25-50 µl) exceed the eye's usual tear-film volume (7 µl) and precorneal reservoir capacity, risking overflow and ocular/systemic complications. Piezoelectric high-precision microdosing may circumvent these limitations. Results & methodology: In this masked, nonrandomized, cross-over study, subjects (n = 12) underwent pupil dilation with topical phenylephrine (PE) administered by 32-µl eyedropper (2.5% or 10% formulation) and 8-µl electronic microdosing (10% formulation). Microdosing with PE-10% achieved comparable peak dilation as 10% eyedropper-delivery and superior dilation to 2.5% eyedropper-delivery (p = 0.009) at 75 min. Microdosing significantly reduced 20-min plasma PE levels versus PE10% eyedropper; neither treatment altered heart rate/blood pressure. Eye irritation occurred significantly less frequently with microdosing than PE10% eyedrops. Piezo-ejection PE microdosing achieves comparable biological effect as eyedropper dosing; reduced systemic absorption may decrease risk of systemic side effects.

  19. Compensating microphonics in SRF cavities to ensure beam stability for future free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel

    2008-07-21

    In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02 in phase and up to 1.10{sup -4} in amplitude. For the planned BESSY-FEL it is envisaged to operate 144 superconducting 1.3 GHz cavities of the 2.3 GeV driver linac in continuous wave mode and at a low beam current. The cavity resonance comprises a very narrow bandwidth of the order of tens of Hertz. Such cavities have been characterized under accelerator like conditions in the HoBiCaT test facility. It was possible to measure the error sources affecting the field stability in continuous wave (CW) operation. Microphonics, the main error source for a mechanical detuning of the cavities, lead to an average fluctuation of the cavity resonance of 1-5 Hz rms. Furthermore, the static and dynamic Lorentz force detuning and the helium pressure dependance of the cavity resonance have been measured. Single cavity RF control and linac bunch-to-bunch longitudinal phase space modeling containing the measured properties showed, that it is advisable to find means to minimize the microphonics detuning by mechanical tuning. Thus, several fast tuning systems have been tested for CW operation. These tuners consist of a motor driven lever for slow and coarse tuning and a piezo that is integrated into the tuner support for fast and fine tuning. Regarding the analysis of the detuning spectrum an adaptive feedforward method based on the least-mean-square filter algorithm has been developed for fast cavity tuning. A detuning compensation between a factor of two and up to a factor of seven has been achieved. Modeling the complete system including the fast tuning scheme, showed that the requirements of the BESSY-FEL are attainable. (orig.)

  20. Compensating microphonics in SRF cavities to ensure beam stability for future free electron lasers

    International Nuclear Information System (INIS)

    Neumann, Axel

    2008-01-01

    In seeded High-Gain-Harmonic-Generation free electron lasers or energy recovery linear accelerators the requirements for the bunch-to-bunch timing and energy jitter of the beam are in the femtosecond and per mill regime. This implies the ability to control the cavity radiofrequency (RF) field to an accuracy of 0.02 in phase and up to 1.10 -4 in amplitude. For the planned BESSY-FEL it is envisaged to operate 144 superconducting 1.3 GHz cavities of the 2.3 GeV driver linac in continuous wave mode and at a low beam current. The cavity resonance comprises a very narrow bandwidth of the order of tens of Hertz. Such cavities have been characterized under accelerator like conditions in the HoBiCaT test facility. It was possible to measure the error sources affecting the field stability in continuous wave (CW) operation. Microphonics, the main error source for a mechanical detuning of the cavities, lead to an average fluctuation of the cavity resonance of 1-5 Hz rms. Furthermore, the static and dynamic Lorentz force detuning and the helium pressure dependance of the cavity resonance have been measured. Single cavity RF control and linac bunch-to-bunch longitudinal phase space modeling containing the measured properties showed, that it is advisable to find means to minimize the microphonics detuning by mechanical tuning. Thus, several fast tuning systems have been tested for CW operation. These tuners consist of a motor driven lever for slow and coarse tuning and a piezo that is integrated into the tuner support for fast and fine tuning. Regarding the analysis of the detuning spectrum an adaptive feedforward method based on the least-mean-square filter algorithm has been developed for fast cavity tuning. A detuning compensation between a factor of two and up to a factor of seven has been achieved. Modeling the complete system including the fast tuning scheme, showed that the requirements of the BESSY-FEL are attainable. (orig.)

  1. Modal Analysis of 27 mm Piezo Electric Plate for Small-Scale Underwater Sonar-Based Navigation

    Directory of Open Access Journals (Sweden)

    M. O. Afolayan

    2013-01-01

    Full Text Available This work presents progress towards the development of a small-scale, purely sonar-based navigation device for a robotic fish (~394 mm long. Aperture overloading of small (5 mm diameter ultrasonic transmitters does not allow them to be used effectively inside water. A test on a 27 mm diameter buzzer piezo plate shows promising performance under water at frequencies from 4.5 kHz to 80 kHz. ANSYS-based simulation was therefore used to find modal frequencies at higher frequencies so as to optimize this encouraging result. The simulation process also discovered several antiresonant frequencies such as 38.5 kHz, 54 kHz, and 57.5 kHz. All frequencies above the 8th harmonic (10,589.02 Hz are out of phase with the input load except a resonance frequency of 42.5 kHz and an antiresonance frequency of 56.5 kHz. Also, the first harmonic (1,648.73 Hz is the only frequency that gave a nodal deformation.

  2. Design and manufacture of a lightweight piezo-composite curved actuator

    Science.gov (United States)

    Yoon, K. Joon; Shin, Seokjun; Park, Hoon C.; Goo, Nam Seo

    2002-02-01

    In this paper we are concerned with the design, manufacture and performance test of a lightweight piezo-composite curved actuator (called LIPCA) using a top carbon fiber composite layer with near-zero coefficient of thermal expansion (CTE), a middle PZT ceramic wafer, and a bottom glass/epoxy layer with a high CTE. The main point of the design for LIPCA is to replace the heavy metal layers of THUNDERTM by lightweight fiber reinforced plastic layers without losing the capabilities for generating high force and large displacement. It is possible to save up to about 40% of the weight if we replace the metallic backing material by the light fiber composite layer. We can also have design flexibility by selecting the fiber direction and the size of prepreg layers. In addition to the lightweight advantage and design flexibility, the proposed device can be manufactured without adhesive layers when we use an epoxy resin prepreg system. Glass/epoxy prepregs, a ceramic wafer with electrode surfaces, and a carbon prepreg were simply stacked and cured at an elevated temperature (177 °C) after following an autoclave bagging process. We found that the manufactured composite laminate device had a sufficient curvature after being detached from a flat mould. An analysis method using the classical lamination theory is presented to predict the curvature of LIPCA after curing at an elevated temperature. The predicted curvatures are in quite good agreement with the experimental values. In order to investigate the merits of LIPCA, performance tests of both LIPCA and THUNDERTM have been conducted under the same boundary conditions. From the experimental actuation tests, it was observed that the developed actuator could generate larger actuation displacement than THUNDERTM.

  3. Low-Level RF Control of Microphonics in Superconducting Spoke-Loaded Cavities

    International Nuclear Information System (INIS)

    Conway, Z.A.; Kelly, M.P.; Sharamentov, S.I.; Shepard, K.W.; Davis, G.; Delayen, Jean; Doolittle, Lawrence

    2007-01-01

    This paper presents the results of cw RF frequency control and RF phase-stabilization experiments performed with a piezoelectric fast tuner mechanically coupled to a superconducting, 345 MHz, < = 0.5 triple-spoke-loaded cavity operating at 4.2K. The piezoelectric fast tuner damped low-frequency microphonic-noise by an order of magnitude. Two methods of RF phase-stabilization were characterized: overcoupling with negative phase feedback, and also fast mechanical tuner feedback. The = 0.5 triple-spoke-loaded cavity RF field amplitude and phase errors were controlled to ±0.5% and ±30 respectively.

  4. Comparison of Piezo-material based Energy Transduction Systems for Artificial Nanoswimmer

    Science.gov (United States)

    Nain, S.; Rathore, J. S.; Sharma, N. N.

    2018-04-01

    The energy harnessing is a process of obtaining energy from the surrounding environment and converting into electrical energy. In the last two decades, there has been a plenteous study in energy harnessing. Now a day, energy harnessing using piezoelectric materials has drawn attention of researchers due to low cost, flexibility and light weight. The benefits of piezoelectric material can be utilized by designing a self-powered device for artificial nanoswimmer. Some of the ceramics which displays the piezoelectric effect are lead-zirconate-titanate (PZT), lead-titanate (PbTiO2), lead-zirconate (PbZrO3) and Barium Titanate (BaTiO3). PZT is most extensively used piezoelectric material in the field of energy harnessing but it is brittle in nature. Lead based piezoelectric materials are toxic in nature and may not suitable for in-vivo biomedical applications. To eradicate this problem, researchers are interested in synthesizing lead free piezoelectric material such as Aluminium Nitride (AIN), Barium Titanate (BaTiO3) and Polyvinylidenefluoride (PVDF). The biocompatibility of PVDF makes it appropriate to be used for energy harnessing in human body for applications like on board powering of nanoswimmer for various disease detection and drug delivery. In this paper, a cantilever beam is being simulated in COMSOL to study electric potential generated on the surface of beam made of different piezoelectric materials such as AIN, PVDF and PZT due to fluidic pressure, which will be utilized as energy for actuation of artificial nanoswimmer. Piezo-based cantilever beams have been compared and maximum electric potential is being observed in PVDF based beam. PVDF seems most promising piezoelectric material for in-vivo biomedical application and it is readily available.

  5. A layer-wise MITC9 finite element for the free-vibration analysis of plates with piezo-patches

    Directory of Open Access Journals (Sweden)

    Maria Cinefra

    2015-04-01

    Full Text Available The present article considers the free-vibration analysis of plate structures with piezoelectric patches by means of a plate finite element with variable through-the-thickness layer-wise kinematic. The refined models used are derived from Carrera’s Unified Formulation (CUF and they permit the vibration modes along the thickness to be accurately described. The finite-element method is employed and the plate element implemented has nine nodes, and the mixed interpolation of tensorial component (MITC method is used to contrast the membrane and shear locking phenomenon. The related governing equations are derived from the principle of virtual displacement, extended to the analysis of electromechanical problems. An isotropic plate with piezoelectric patches is analyzed, with clamped-free boundary conditions and subjected to open- and short-circuit configurations. The results, obtained with different theories, are compared with the higher-order type solutions given in the literature. The conclusion is reached that the plate element based on the CUF is more suitable and efficient compared to the classical models in the study of multilayered structures embedding piezo-patches.

  6. Thermoelectrically induced nonlinear free vibration analysis of piezo laminated composite conical shell panel with random fiber orientation

    Directory of Open Access Journals (Sweden)

    Lal Achchhe

    2017-09-01

    Full Text Available This paper presents the free vibration response of piezo laminated composite geometrically nonlinear conical shell panel subjected to a thermo-electrical loading. The temperature field is assumed to be a uniform distribution over the shell surface and through the shell thickness and the electric field is assumed to be the transverse component E2 only. The material properties are assumed to be independent of the temperature and the electric field. The basic formulation is based on higher order shear deformation plate theory (HSDT with von-Karman nonlinearity. A C0 nonlinear finite element method based on direct iterative approach is outlined and applied to solve nonlinear generalized eigenvalue problem. Parametric studies are carried out to examine the effect of amplitude ratios, stacking sequences, cone angles, piezoelectric layers, applied voltages, circumferential length to thickness ratios, change in temperatures and support boundary conditions on the nonlinear natural frequency of laminated conical shell panels. The present outlined approach has been validated with those available results in the literature.

  7. Substances toxiques persistantes (PTS dans les corps gras : État des lieux d’après le rapport du programme des Nations-Unies pour l’environnement (PNUE

    Directory of Open Access Journals (Sweden)

    Narbonne Jean François

    2003-07-01

    Full Text Available Depuis plus de trente ans, une attention croissante a été portée sur les risques pour la santé humaine posés par la contamination de l’environnement par les substances toxiques persistantes (PTS. Ces composés persistent pendant de longues périodes dans les compartiments abiotiques et biotiques, sont transportés sur de longues distances depuis leurs points sources et s’accumulent chez l’homme et les organismes via les chaînes alimentaires. En 1997, le PNUE propose une liste initiale de 12 substances appelées polluants organiques persistants (POPs : aldrine, endrine, dieldrine, chordane, DDT, heptachlore, toxaphène, mirex, hexachlorobenzène, PCBs, dioxines (PCDDs, furanes (PCDFs. En 2001, de nouveaux composés sont ajoutés sur la liste des PTS en fonction de leurs caractéristiques comme la liposolubilité, leur résistance à la dégradation, leur forte toxicité ou la constance des apports : hexachlorohexane, PAHs, endosulfan, pentachlorophénol, formes organiques des métaux lourds : mercure, étain et plomb, phtalates, PBDEs\\\\PBBs, chlordécone, alkyl phénols, atrazine. Les sources de PTS sont diverses : (1 Utilisation de produits chimiques industriels comme les pesticides ou les emballages, (2 Réservoirs historiques déjà présents dans l’environnement essentiellement dans les sols et les sédiments ou sous forme de stocks périmés, (3 Sous-produits de process, en particulier comme contaminants indésirables de procédés industriels et de combustion. La France a été associée au rapport de la région IV méditerranéenne. Les niveaux dans les compartiments de l’environnement sont rapportés et l’exposition de l’homme via l’alimentation (vecteur essentiel est estimée en fonction des données collectées. Une évaluation des risques associés a été faite quand les données étaient suffisantes (PAHs, PCBs, PCDD\\\\F, Me Hg. Les lipides apparaissent comme vecteurs majeurs des PTS à travers la cha

  8. Activation of Mechanosensitive Transient Receptor Potential/Piezo Channels in Odontoblasts Generates Action Potentials in Cocultured Isolectin B4-negative Medium-sized Trigeminal Ganglion Neurons.

    Science.gov (United States)

    Sato, Masaki; Ogura, Kazuhiro; Kimura, Maki; Nishi, Koichi; Ando, Masayuki; Tazaki, Masakazu; Shibukawa, Yoshiyuki

    2018-04-27

    Various stimuli to the dentin surface elicit dentinal pain by inducing dentinal fluid movement causing cellular deformation in odontoblasts. Although odontoblasts detect deformation by the activation of mechanosensitive ionic channels, it is still unclear whether odontoblasts are capable of establishing neurotransmission with myelinated A delta (Aδ) neurons. Additionally, it is still unclear whether these neurons evoke action potentials by neurotransmitters from odontoblasts to mediate sensory transduction in dentin. Thus, we investigated evoked inward currents and evoked action potentials form trigeminal ganglion (TG) neurons after odontoblast mechanical stimulation. We used patch clamp recordings to identify electrophysiological properties and record evoked responses in TG neurons. We classified TG cells into small-sized and medium-sized neurons. In both types of neurons, we observed voltage-dependent inward currents. The currents from medium-sized neurons showed fast inactivation kinetics. When mechanical stimuli were applied to odontoblasts, evoked inward currents were recorded from medium-sized neurons. Antagonists for the ionotropic adenosine triphosphate receptor (P2X 3 ), transient receptor potential channel subfamilies, and Piezo1 channel significantly inhibited these inward currents. Mechanical stimulation to odontoblasts also generated action potentials in the isolectin B 4 -negative medium-sized neurons. Action potentials in these isolectin B 4 -negative medium-sized neurons showed a short duration. Overall, electrophysiological properties of neurons indicate that the TG neurons with recorded evoked responses after odontoblast mechanical stimulation were myelinated Aδ neurons. Odontoblasts established neurotransmission with myelinated Aδ neurons via P2X 3 receptor activation. The results also indicated that mechanosensitive TRP/Piezo1 channels were functionally expressed in odontoblasts. The activation of P2X 3 receptors induced an action potential

  9. Flexible Self-Powered GaN Ultraviolet Photoswitch with Piezo-Phototronic Effect Enhanced On/Off Ratio.

    Science.gov (United States)

    Peng, Mingzeng; Liu, Yudong; Yu, Aifang; Zhang, Yang; Liu, Caihong; Liu, Jingyu; Wu, Wei; Zhang, Ke; Shi, Xieqing; Kou, Jinzong; Zhai, Junyi; Wang, Zhong Lin

    2016-01-26

    Flexible self-powered sensing is urgently needed for wearable, portable, sustainable, maintenance-free and long-term applications. Here, we developed a flexible and self-powered GaN membrane-based ultraviolet (UV) photoswitch with high on/off ratio and excellent sensitivity. Even without any power supply, the driving force of UV photogenerated carriers can be well boosted by the combination of both built-in electric field and piezoelectric polarization field. The asymmetric metal-semiconductor-metal structure has been elaborately utilized to enhance the carrier separation and transport for highly sensitive UV photoresponse. Its UV on/off ratio and detection sensitivity reach to 4.67 × 10(5) and 1.78 × 10(12) cm·Hz(0.5) W(1-), respectively. Due to its excellent mechanical flexibility, the piezoelectric polarization field in GaN membrane can be easily tuned/controlled based on piezo-phototronic effect. Under 1% strain, a stronger and broader depletion region can be obtained to further enhance UV on/off ratio up to 154%. As a result, our research can not only provide a deep understanding of local electric field effects on self-powered optoelectronic detection, but also promote the development of self-powered flexible optoelectronic devices and integrated systems.

  10. Piezo-Phototronic Effect Controlled Dual-Channel Visible light Communication (PVLC) Using InGaN/GaN Multiquantum Well Nanopillars.

    Science.gov (United States)

    Du, Chunhua; Jiang, Chunyan; Zuo, Peng; Huang, Xin; Pu, Xiong; Zhao, Zhenfu; Zhou, Yongli; Li, Linxuan; Chen, Hong; Hu, Weiguo; Wang, Zhong Lin

    2015-12-02

    Visible light communication (VLC) simultaneously provides illumination and communication via light emitting diodes (LEDs). Keeping a low bit error rate is essential to communication quality, and holding a stable brightness level is pivotal for illumination function. For the first time, a piezo-phototronic effect controlled visible light communication (PVLC) system based on InGaN/GaN multiquantum wells nanopillars is demonstrated, in which the information is coded by mechanical straining. This approach of force coding is also instrumental to avoid LED blinks, which has less impact on illumination and is much safer to eyes than electrical on/off VLC. The two-channel transmission mode of the system here shows great superiority in error self-validation and error self-elimination in comparison to VLC. This two-channel PVLC system provides a suitable way to carry out noncontact, reliable communication under complex circumstances. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Flexible Light Emission Diode Arrays Made of Transferred Si Microwires-ZnO Nanofilm with Piezo-Phototronic Effect Enhanced Lighting.

    Science.gov (United States)

    Li, Xiaoyi; Liang, Renrong; Tao, Juan; Peng, Zhengchun; Xu, Qiming; Han, Xun; Wang, Xiandi; Wang, Chunfeng; Zhu, Jing; Pan, Caofeng; Wang, Zhong Lin

    2017-04-25

    Due to the fragility and the poor optoelectronic performances of Si, it is challenging and exciting to fabricate the Si-based flexible light-emitting diode (LED) array devices. Here, a flexible LED array device made of Si microwires-ZnO nanofilm, with the advantages of flexibility, stability, lightweight, and energy savings, is fabricated and can be used as a strain sensor to demonstrate the two-dimensional pressure distribution. Based on piezo-phototronic effect, the intensity of the flexible LED array can be increased more than 3 times (under 60 MPa compressive strains). Additionally, the device is stable and energy saving. The flexible device can still work well after 1000 bending cycles or 6 months placed in the atmosphere, and the power supplied to the flexible LED array is only 8% of the power of the surface-contact LED. The promising Si-based flexible device has wide range application and may revolutionize the technologies of flexible screens, touchpad technology, and smart skin.

  12. A piezo motor based on a new principle with high output force, rigidity and integrity: The Tuna Drive

    Science.gov (United States)

    Liu, Xiaolong; Lu, Qingyou

    2012-11-01

    We present a linear piezoelectric motor as simple as one piezoelectric scanner tube (PST) spring-clamping a central shaft at both ends with roughly equal clamping forces. The clamping points are aligned with ±X electrodes at one end and ±Y electrodes at the other end. Thus, the ±X (or ±Y) push-pull motions of the PST can cause the push-pull motions of the clamping points on the shaft (called push-pull rubbing), which reduces the total dynamic friction force at one (or the other) end of the PST. This new piezo motor advances one step by fast push-pull rubbing at one end while slowly retracting the PST followed by fast push-pull rubbing at the other end while slowly elongating the PST. Apart from the obvious advantages of simplicity, rigidity, integrity, etc., we will also show that this motor can produce a large output force, which we believe is because of the huge drop of the clamping friction force when the push-pull rubbing occurs.

  13. Robust Comparison of the Linear Model Structures in Self-tuning Adaptive Control

    DEFF Research Database (Denmark)

    Zhou, Jianjun; Conrad, Finn

    1989-01-01

    The Generalized Predictive Controller (GPC) is extended to the systems with a generalized linear model structure which contains a number of choices of linear model structures. The Recursive Prediction Error Method (RPEM) is used to estimate the unknown parameters of the linear model structures...... to constitute a GPC self-tuner. Different linear model structures commonly used are compared and evaluated by applying them to the extended GPC self-tuner as well as to the special cases of the GPC, the GMV and MV self-tuners. The simulation results show how the choice of model structure affects the input......-output behaviour of self-tuning controllers....

  14. In situ ZnO nanowire growth to promote the PVDF piezo phase and the ZnO-PVDF hybrid self-rectified nanogenerator as a touch sensor.

    Science.gov (United States)

    Li, Zetang; Zhang, Xu; Li, Guanghe

    2014-03-28

    A PVDF-ZnO nanowires (NWs) hybrid generator (PZHG) was designed. A simple, cost effective method to produce the PVDF β phase by nano force is introduced. With the ZnO NWs growing, the in situ nano extension force promotes the phase change. A theoretical analysis of the ZnO NWs acting as a self-rectifier of the nano generator is established. The ZnO NWs acted as a self-adjustment diode to control the current output of the PZHG by piezo-electric and semi-conductive effects. Based on the self-controllability of the piezoelectric output, three kinds of finger touching are distinguished by the output performances of the PZHG, which is applicable to an LCD touch pad.

  15. Two-Dimensional Micro-/Nanoradian Angle Generator with High Resolution and Repeatability Based on Piezo-Driven Double-Axis Flexure Hinge and Three Capacitive Sensors.

    Science.gov (United States)

    Tan, Xinran; Zhu, Fan; Wang, Chao; Yu, Yang; Shi, Jian; Qi, Xue; Yuan, Feng; Tan, Jiubin

    2017-11-19

    This study presents a two-dimensional micro-/nanoradian angle generator (2D-MNAG) that achieves high angular displacement resolution and repeatability using a piezo-driven flexure hinge for two-dimensional deflections and three capacitive sensors for output angle monitoring and feedback control. The principal error of the capacitive sensor for precision microangle measurement is analyzed and compensated for; so as to achieve a high angle output resolution of 10 nrad (0.002 arcsec) and positioning repeatability of 120 nrad (0.024 arcsec) over a large angular range of ±4363 μrad (±900 arcsec) for the 2D-MNAG. The impact of each error component, together with the synthetic error of the 2D-MNAG after principal error compensation are determined using Monte Carlo simulation for further improvement of the 2D-MNAG.

  16. Comparison report of RPV pressurised thermal shock - international comparative assessment study (PTS ICAS)

    International Nuclear Information System (INIS)

    1999-01-01

    A summary of the recently completed International Comparative Assessment Study of Pressurized- Thermal-Shock in Reactor Pressure Vessels (RPV PTS ICAS) is presented here to record the results in actual and comparative fashions. The ICAS Project brought together an international group of experts from research, utility and regulatory organizations to perform a comparative evaluation of analysis methodologies employed in the assessment of RPV integrity under PTS loading conditions. The Project was sponsored jointly by Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS), Koeln, Germany, and Oak Ridge National Laboratory (ORNL), USA, with assistance from the Organization for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA)/Committee on the Safety of Nuclear Installations (CSNI)/Principal Working Group (PWG) No. 3 (Integrity of Components and Structures). The ICAS Project grew out of a strong interest expressed by participants in the previous FALSIRE II Project to proceed with further evaluations of analysis methods used in RPV integrity assessment. A Launch Meeting for the ICAS Project was held at GRS-Koeln, during June 1996, where an emphasis was placed on identifying the different approaches to RPV integrity assessment being employed within the international nuclear technology community. Also a Problem Statement was drafted that defined a Western type four-loop RPV with cladding on the inner surface. Also, a detailed task matrix was defined that included a set of transient thermal-mechanical loading conditions postulated to result from loss-of-coolant accidents. The primary focus of the analyses was on the behaviour of relatively shallow cracks under these conditions. The assessment activities based on the Problem Statement were divided under three tasks: deterministic fracture mechanics (DFM), probabilistic fracture mechanics (PFM) and thermal-hydraulic mixing (THM). An Intermediate Workshop was held at OECD/NEA-Paris during June 1997, to

  17. Mechanical design of 56 MHz superconducting RF cavity for RHIC collider

    Energy Technology Data Exchange (ETDEWEB)

    Pai, C.; Ben-Zvi, I.; Burrill, A.; Chang, X.; McIntyre, G.; Than, Y.; Tuozzolo, J.; Wu, Q.

    2011-03-28

    A 56 MHz Superconducting RF Cavity operating at 4.4K is being constructed for the RHIC collider. This cavity is a quarter wave resonator with beam transmission along the centerline. This cavity will increase collision luminosity by providing a large longitudinal bucket for stored bunches of RHIC ion beam. The major components of this assembly are the niobium cavity with the mechanical tuner, its titanium helium vessel and vacuum cryostat, the support system, and the ports for HOM and fundamental dampers. The cavity and its helium vessel must meet equivalent safety with the ASME pressure vessel code and it must not be sensitive to frequency shift due to pressure fluctuations from the helium supply system. Frequency tuning achieved by a two stage mechanical tuner is required to meet performance parameters. This tuner mechanism pushes and pulls the tuning plate in the gap of niobium cavity. The tuner mechanism has two separate drive systems to provide both coarse and fine tuning capabilities. This paper discusses the design detail and how the design requirements are met.

  18. Two-Dimensional Micro-/Nanoradian Angle Generator with High Resolution and Repeatability Based on Piezo-Driven Double-Axis Flexure Hinge and Three Capacitive Sensors

    Directory of Open Access Journals (Sweden)

    Xinran Tan

    2017-11-01

    Full Text Available This study presents a two-dimensional micro-/nanoradian angle generator (2D-MNAG that achieves high angular displacement resolution and repeatability using a piezo-driven flexure hinge for two-dimensional deflections and three capacitive sensors for output angle monitoring and feedback control. The principal error of the capacitive sensor for precision microangle measurement is analyzed and compensated for; so as to achieve a high angle output resolution of 10 nrad (0.002 arcsec and positioning repeatability of 120 nrad (0.024 arcsec over a large angular range of ±4363 μrad (±900 arcsec for the 2D-MNAG. The impact of each error component, together with the synthetic error of the 2D-MNAG after principal error compensation are determined using Monte Carlo simulation for further improvement of the 2D-MNAG.

  19. Energetic optimization of a piezo-based touch-operated button for man–machine interfaces

    International Nuclear Information System (INIS)

    Sun, Hao; De Vries, Theo J A; De Vries, Rene; Van Dalen, Harry

    2012-01-01

    This paper discusses the optimization of a touch-operated button for man–machine interfaces based on piezoelectric energy harvesting techniques. In the mechanical button, a common piezoelectric diaphragm, is assembled to harvest the ambient energy from the source, i.e. the operator’s touch. Under touch force load, the integrated diaphragm will have a bending deformation. Then, its mechanical strain is converted into the required electrical energy by means of the piezoelectric effect presented to the diaphragm. Structural design (i) makes the piezoceramic work under static compressive stress instead of static or dynamic tensile stress, (ii) achieves a satisfactory stress level and (iii) provides the diaphragm and the button with a fatigue lifetime in excess of millions of touch operations. To improve the button’s function, the effect of some key properties consisting of dimension, boundary condition and load condition on electrical behavior of the piezoelectric diaphragm are evaluated by electromechanical coupling analysis in ANSYS. The finite element analysis (FEA) results indicate that the modification of these properties could enhance the diaphragm significantly. Based on the key properties’ different contributions to the improvement of the diaphragm’s electrical energy output, they are incorporated into the piezoelectric diaphragm’s redesign or the structural design of the piezo-based button. The comparison of the original structure and the optimal result shows that electrical energy stored in the diaphragm and the voltage output are increased by 1576% and 120%, respectively, and the volume of the piezoceramic is reduced to 33.6%. These results will be adopted to update the design of the self-powered button, thus enabling a large decrease of energy consumption and lifetime cost of the MMI. (paper)

  20. A Temperature Compensation Method for Piezo-Resistive Pressure Sensor Utilizing Chaotic Ions Motion Algorithm Optimized Hybrid Kernel LSSVM

    Directory of Open Access Journals (Sweden)

    Ji Li

    2016-10-01

    Full Text Available A piezo-resistive pressure sensor is made of silicon, the nature of which is considerably influenced by ambient temperature. The effect of temperature should be eliminated during the working period in expectation of linear output. To deal with this issue, an approach consists of a hybrid kernel Least Squares Support Vector Machine (LSSVM optimized by a chaotic ions motion algorithm presented. To achieve the learning and generalization for excellent performance, a hybrid kernel function, constructed by a local kernel as Radial Basis Function (RBF kernel, and a global kernel as polynomial kernel is incorporated into the Least Squares Support Vector Machine. The chaotic ions motion algorithm is introduced to find the best hyper-parameters of the Least Squares Support Vector Machine. The temperature data from a calibration experiment is conducted to validate the proposed method. With attention on algorithm robustness and engineering applications, the compensation result shows the proposed scheme outperforms other compared methods on several performance measures as maximum absolute relative error, minimum absolute relative error mean and variance of the averaged value on fifty runs. Furthermore, the proposed temperature compensation approach lays a foundation for more extensive research.

  1. Design and experimental research of a novel inchworm type piezo-driven rotary actuator with the changeable clamping radius.

    Science.gov (United States)

    Zhao, Hongwei; Fu, Lu; Ren, Luquan; Huang, Hu; Fan, Zunqiang; Li, Jianping; Qu, Han

    2013-01-01

    In this paper, a novel piezo-driven rotary actuator with the changeable clamping radius is developed based on the inchworm principle. This actuator mainly utilizes three piezoelectric actuators, a flexible gripper, a clamping block, and a rotor to achieve large stroke rotation with high resolution. The design process of the flexible gripper consisting of the driving unit and the clamping unit is described. Lever-type mechanisms were used to amplify the micro clamping displacements. The amplifying factor and parasitic displacement of the lever-type mechanism in the clamping unit was analyzed theoretically and experimentally. In order to investigate the rotation characteristics of the actuator, a series of experiments was carried out. Experimental results indicate that the actuator can rotate at a speed of 77,488 μrad/s with a driving frequency of 167 Hz. The rotation resolution and maximum load torque of the actuator are 0.25 μrad and 37 N mm, respectively. The gripper is movable along the z direction based on an elevating platform, and the clamping radius can change from 10.6 mm to 25 mm. Experimental results confirm that the actuator can achieve different rotation speeds by changing the clamping radius.

  2. A Temperature Compensation Method for Piezo-Resistive Pressure Sensor Utilizing Chaotic Ions Motion Algorithm Optimized Hybrid Kernel LSSVM.

    Science.gov (United States)

    Li, Ji; Hu, Guoqing; Zhou, Yonghong; Zou, Chong; Peng, Wei; Alam Sm, Jahangir

    2016-10-14

    A piezo-resistive pressure sensor is made of silicon, the nature of which is considerably influenced by ambient temperature. The effect of temperature should be eliminated during the working period in expectation of linear output. To deal with this issue, an approach consists of a hybrid kernel Least Squares Support Vector Machine (LSSVM) optimized by a chaotic ions motion algorithm presented. To achieve the learning and generalization for excellent performance, a hybrid kernel function, constructed by a local kernel as Radial Basis Function (RBF) kernel, and a global kernel as polynomial kernel is incorporated into the Least Squares Support Vector Machine. The chaotic ions motion algorithm is introduced to find the best hyper-parameters of the Least Squares Support Vector Machine. The temperature data from a calibration experiment is conducted to validate the proposed method. With attention on algorithm robustness and engineering applications, the compensation result shows the proposed scheme outperforms other compared methods on several performance measures as maximum absolute relative error, minimum absolute relative error mean and variance of the averaged value on fifty runs. Furthermore, the proposed temperature compensation approach lays a foundation for more extensive research.

  3. Piezoelektrisches Aktormodul sowie piezoelektrischer Aktor mit einem solchen piezoelektrischen Aktormodul und Herstellungsverfahren für diese

    OpenAIRE

    Roscher, H.-J.; Anselment, C.; Just, D.; Seffner, L.; Moritz, T.

    2010-01-01

    The module (13) has two piezo stacks (1, 2) arranged on a common carrier (3) i.e. base plate. One of the piezo stacks is formed as an active piezo element and the other piezo stack is formed as a passive body that is made of metal and/or ceramic. The piezo stacks are partially molded with plastic. A separator e.g. PTFE film, is arranged between the piezo stacks. The separator is provided in surface contact with opposing faces of the piezo stacks. The piezo stacks are designed as multilayer ac...

  4. Two-degrees-of-freedom piezo-driven fast steering mirror with cross-axis decoupling capability

    Science.gov (United States)

    Shao, Shubao; Tian, Zheng; Song, Siyang; Xu, Minglong

    2018-05-01

    Because mechanical cross coupling between its axes would lead to degradation of the scanning precision of a piezo-driven fast steering mirror (PFSM), a two-degrees-of-freedom (2-DoF) PFSM with a cross-axis decoupling capability, in which 2-DoF flexure hinges are used, is proposed in this work. The overall structure of the proposed PFSM is first introduced and then both static and dynamic models are established analytically; in addition, the decoupling mechanism is described in detail and the low dynamic cross coupling ratios that occur between the two DoFs are shown. Because of the decoupling property of the PFSM, the 2-DoF motion is treated as a combination of two independent one-degree-of-freedom (1-DoF) motions and two independent proportional-integral-derivative controllers are thus used separately in the control of the two DoFs. Based on this control strategy, experiments involving both 1-DoF trajectory tracking and 2-DoF trajectory tracking are implemented. The test results show that the proposed PFSM can achieve the tilt range of ±7 mrad for both axes with the low coupling ratios that are less than 2% (-34 dB), and the bandwidths of both axes are higher than 810 Hz; in addition, the maximal tracking full scale range errors for 1-DoF trajectory tracking and 2-DoF trajectory tracking are less than 0.2% and 1%, respectively, where the larger error of 2-DoF trajectory tracking is mainly caused by the remaining cross coupling between axes.

  5. ZettaBricks: A Language Compiler and Runtime System for Anyscale Computing

    Energy Technology Data Exchange (ETDEWEB)

    Amarasinghe, Saman [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-03-27

    This grant supported the ZettaBricks and OpenTuner projects. ZettaBricks is a new implicitly parallel language and compiler where defining multiple implementations of multiple algorithms to solve a problem is the natural way of programming. ZettaBricks makes algorithmic choice a first class construct of the language. Choices are provided in a way that also allows our compiler to tune at a finer granularity. The ZettaBricks compiler autotunes programs by making both fine-grained as well as algorithmic choices. Choices also include different automatic parallelization techniques, data distributions, algorithmic parameters, transformations, and blocking. Additionally, ZettaBricks introduces novel techniques to autotune algorithms for different convergence criteria. When choosing between various direct and iterative methods, the ZettaBricks compiler is able to tune a program in such a way that delivers near-optimal efficiency for any desired level of accuracy. The compiler has the flexibility of utilizing different convergence criteria for the various components within a single algorithm, providing the user with accuracy choice alongside algorithmic choice. OpenTuner is a generalization of the experience gained in building an autotuner for ZettaBricks. OpenTuner is a new open source framework for building domain-specific multi-objective program autotuners. OpenTuner supports fully-customizable configuration representations, an extensible technique representation to allow for domain-specific techniques, and an easy to use interface for communicating with the program to be autotuned. A key capability inside OpenTuner is the use of ensembles of disparate search techniques simultaneously; techniques that perform well will dynamically be allocated a larger proportion of tests.

  6. Tuning the LEDA RFQ 6.7 MeV accelerator

    International Nuclear Information System (INIS)

    Young, L.M.; Rybarcyk, L.

    1998-01-01

    This paper presents the results of tuning the 8 meter long Radio Frequency Quadrupole (RFQ) built for the Low Energy Demonstration Accelerator (LEDA). This 350-MHz RFQ is split into four 2-meter-long-RFQs. Then they are joined with resonant coupling to form an 8-meter-long RFQ. This improves both the longitudinal stability and the transverse stability of this long RFQ. The frequencies of the modes near the RFQ mode are measured. The authors show the effect on the RF fields of an error in the temperature of each one of the 2-meter-long-RFQs. Slug tuners distributed along the outer walls tune the RFQ. The program RFQTUNE is used to determine the length of the tuners. The tuners are machined to length when the final tuning is complete

  7. RF Measurements and Tuning of the 750 MHz HF-RFQ

    CERN Document Server

    Koubek, Benjamin; Timmins, Marc; CERN. Geneva. ATS Department

    2017-01-01

    In the frame of the program on medical applications CERN has built a compact 750 MHz RFQ to be used as an injector for a hadron therapy linac. This RFQ was designed to accelerate protons to an energy of 5 {\\lambda} MeV within only 2 m length. It is divided into four segments and equipped with 32 tuners in total. The length of the RFQ corresponds to 5 which is considered to be close to the limit for field adjustment using only piston tuners. Moreover the high frequency, which is about double the frequency of existing RFQs, results in a sensitive structure and requires careful tuning by means of the alignment of the pumping ports and fixed tuners. This report summarises the tuning procedure, RF and bead pull measurements of the RFQ.

  8. Bronchoplastic operations for lung cancer

    International Nuclear Information System (INIS)

    Cicenas, S.; Naujokaitis, P.; Jackevicius, A. and others

    2002-01-01

    Objective of our work was to evaluate efficacy of bronchoplastic operations for lung cancer and time to progression in combined treatment. From 1997 till 2001, 57pts were operated for early I-IIB stages of lung cancer. Operations were: tracheal resections in 3pts (5.2%), window right pneumonectomies in 5pts (8.7%), window left pneumonectomies in 2pts (3.5%), window right upper lobe in 22pts (38.5%), bifurcation resections 2pts (3.5%), sleeve right upper lobe resections 7pts (12.2%), sleeve left upper lobe resections in 11pts (19.2%). We had complications: in 7pts (12.2%) suture failure, 26pts (45.6%) obstructive pneumonia, 3pts (5.2%) kinking of anastomosis, 2pts (3.7%) bronchial bleeding, 6pts (10.5%) covered bronchial fistulas, 5pts (8.7%) died after operations. 32pts (56%) underwent radiation after surgery, 13pts (22.8%) radiation and chemotherapy. Three-year survival was in 82.4% (47pts), in 10pts (17.4%) disease progressed. Bronchoplastic operations are sufficient for early lung cancer treatment. Three-year was in survival 82.7% of pts. Seventeen percent of patients failed after combined treatment. (author)

  9. A fully variable, piezo-actuated research injection system as a tool in diesel engine combustion process development; Ein vollvariables, piezoaktuiertes Foschungs-Einspritzsystem als Werkzeug in der dieselmotorischen Brennverfahrensentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, S.; Stegemann, J.; Seebode, J.; Merker, G.P. [Hannover Univ. (Germany). Inst. fuer Technische Verbrennung

    2004-07-01

    The injection process is a central optimisation approach for low-cost, low-emission diesel engines. An injection system is presented which comprises a pressure modulator and a research injector with piezo-actuated direct actuation of the nozzle. The high flexibility of the system enables systematic investigations of different combustion processes. (orig.) [German] Die Einspritzverlaufsformung als Mittel zur Minimierung von Rohemissionen bleibt auch im heutigen, von Diskussionen und Partikelfilter und Entstickungstechnologien gepraegten Umfeld ein zentraler Optimierungsansatz fuer kostenguenstige und emissionsarme Dieselmotoren. Das hier vorgestellte Einspritzsystem, bestehend aus einer Druckmodulationseinheit und einem Forschungsinjektor mit piezogesteuerter Direktansteuerung der Duesennadel, dient zur Potenzialanalyse einer freien Einspritzverlaufsformung als Mittel zur innermotorischen Brennverfahrensoptimierung. Dank der hohen Flexibilitaet des Systems sind systematische Untersuchungen in Bezug auf unterschiedliche Brennverfahren moeglich. (orig.)

  10. A perpendicular AC biased ferrite tuned cavity for the TRIUMF KAON factory booster synchrotron

    International Nuclear Information System (INIS)

    Poirier, R.L.; Enegren, T.A.; Haddock, C.; Enchevich, I.

    1990-06-01

    The rf cavity for the booster synchrotron requires a frequency swing of 46 MHz at a repetition rate of 50 Hz. This will be accomplished using a tuner containing yttrium garnet ferrite where the bias field is perpendicular to the rf magnetic field. Conventional methods use parallel biased NiZn ferrite. Yttrium garnet ferrite possess a high electric quality factor. However the ac magnetizing circuit is much more complicated and special care must be taken to minimize the induced eddy current losses when designing the tuner. A dc biased prototype cavity was constructed and tested at Los Alamos. As part of the project definition study for the proposed KAON factory, this cavity has now been almost entirely rebuilt at TRIUMF with a completely redesigned tuner for ac bias operation. Measurements and test results will be reported. (Author) 2 refs., 8 figs

  11. Fundamental Frequency Tuning and Its Influence on LHC 200MHz ACN Cavity

    CERN Document Server

    Linnecar, Trevor Paul R; Tückmantel, Joachim; CERN. Geneva. SPS and LHC Division

    2001-01-01

    To study the influence of the tuner on the fundamental mode frequency, the Q factor as well as the shunt impedance of the LHC 200MHz ACN cavities, 3D simulations have been done in the frequency domain using MAFIA. Curves giving the variation of RF frequency and other RF parameters with tuner position relative to the inner surface of the cavity have been obtained for the fundamental mode. This paper details the simulation results.

  12. A micro-optical system for endoscopy based on mechanical compensation paradigm using miniature piezo-actuation.

    Science.gov (United States)

    Cerveri, Pietro; Zazzarini, Cynthia Corinna; Patete, Paolo; Baroni, Guido

    2014-06-01

    The goal of the study was to investigate the feasibility of a novel miniaturized optical system for endoscopy. Fostering the mechanical compensation paradigm, the modeled optical system, composed by 14 lenses, separated in 4 different sets, had a total length of 15.55mm, an effective focal length ranging from 1.5 to 4.5mm with a zoom factor of about 2.8×, and an angular field of view up to 56°. Predicted maximum lens travel was less than 3.5mm. The consistency of the image plane height across the magnification range testified the zoom capability. The maximum predicted achromatic astigmatism, transverse spherical aberration, longitudinal spherical aberration and relative distortion were less than or equal to 25μm, 15μm, 35μm and 12%, respectively. Tests on tolerances showed that the manufacturing and opto-mechanics mounting are critical as little deviations from design dramatically decrease the optical performances. However, recent micro-fabrication technology can guarantee tolerances close to nominal design. A closed-loop actuation unit, devoted to move the zoom and the focus lens sets, was implemented adopting miniaturized squiggle piezo-motors and magnetic position encoders based on Hall effect. Performance results, using a prototypical test board, showed a positioning accuracy of less than 5μm along a lens travel path of 4.0mm, which was in agreement with the lens set motion features predicted by the analysis. In conclusion, this study demonstrated the feasibility of the optical design and the viability of the actuation approach while tolerances must be carefully taken into account. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Validation of the superconducting 3.9 GHz cavity package for the European X-ray Free Electron Laser

    Science.gov (United States)

    Maiano, C. G.; Branlard, J.; Hüning, M.; Jensch, K.; Kostin, D.; Matheisen, A.; Möller, W.-D.; Sulimov, A.; Vogel, E.; Bosotti, A.; Chen, J. F.; Moretti, M.; Paparella, R.; Pierini, P.; Sertore, D.

    2017-04-01

    A full test of the cavity package concept under realistic operating condition was a necessary step before the assembly of the European XFEL (EXFEL) 3.9 GHz superconducting system and its installation in the accelerator. One cavity, equipped with magnetic shielding, power coupler and frequency tuner has been tested in a specially designed single cavity cryostat in one of the test benches of the DESY Accelerator Module Test Facility (AMTF). The cavity was operated at high pulsed power up to an accelerating field of 24 MV /m , above the quench accelerating field of 21 MV /m achieved during the continuous wave (CW) vertical qualification test and with a large margin with respect to the EXFEL maximum operating specification of 15 MV /m for the 3.9 GHz system. All subsystems under test—coupler, tuner, waveguide tuners, low level radio-frequency (LLRF) system—were qualified to their design performances.

  14. The effect of actuator bending on Lamb wave displacement fields generated by a piezoelectric patch

    International Nuclear Information System (INIS)

    Huang, H; Pamphile, T; Derriso, M

    2008-01-01

    A Lamb wave is a special type of elastic wave that is widely employed in structural health monitoring systems for damage detection. Recently, piezoelectric (piezo) patches have become popular for Lamb wave excitation and sensing because one piezo patch can serve as both the actuator and the sensor. All published work has assumed that the Lamb wave displacement field generated by a piezo patch actuator is axi-symmetric. However, we observed that piezo sensors placed at equal distances from the piezo patch actuator displayed different responses. In order to understand this phenomenon, we used a laser vibrometer to measure the full-field displacements around a circular piezo actuator noncontactly. The displacement fields excited by the piezo patch actuator are found to be directional, and this directionality is also frequency dependent, indicating that the out-of-plane bending dynamics of the piezo actuator may play an important role in the Lamb wave displacement fields. A simulation model that incorporates the bending deformation of the piezo patch into the calculations of the Lamb wave generation is then developed. The agreement between the simulated and measured displacement fields confirmed that the directionality of the Lamb wave displacement fields is governed by the bending deformation of the piezo patch actuator

  15. Effect of flexure beam geometry and material on the displacement of piezo actuated diaphragm for micropump

    Science.gov (United States)

    Roopa, R.; Navin Karanth, P.; Kulkarni, S. M.

    2018-02-01

    In this paper, we present a COMSOL analysis of flexure diaphragm for piezo actuated valveless micropump. Diaphragms play an important role in micropumps, till now plane diaphragms are commonly used in micropumps. Use of compliant flexure hinges in diaphragm and other MEMS application is one of the new approach to achieving high deflection in diaphragm at low operating voltage. Flexures hinges in diaphragm acts as simply supported beam. Out-off plane compliance value and stiffness is considered for the selection of proper flexure for diaphragm. Diaphragm material also plays an important role in the diaphragm central deflection. Factor considered for diaphragm material selection is resilience; it is the ratio of yield stress to static modulus. Higher is the resilience will leads to higher deflection generated, it also imparts good compliance. Based on the resilience beryllium copper, stainless steel and brass materials are selected for diaphragm analysis. Simulations have been performed using COMSOL multiphysics. This study reports the effect of flexure hinge geometry and diaphragm material on the central deflection of diaphragms and compared with existing plane diaphragm. Simulation results illustrates that the deflection of three flexure diaphragm with 2mm width and 2mm length flexure is 6.75µm for stainless steel, 10.89 for beryllium copper and 12.10µm for brass, at 140V which is approximately twice that of plane diaphragm deflection. The maximum in both plane and three flexure diaphragm deflection is obtained for brass diaphragm compared to stainless steel and beryllium copper.

  16. Numerical simulation of the direct contact condensation phenomena for PTS-related in single and combined-effect thermal hydraulic test facilities using TransAT CMFD code

    Energy Technology Data Exchange (ETDEWEB)

    Kadi, Rabah, E-mail: kadi.rkhaled@hotmail.com [Laboratory for Thermal-Hydraulics, Nuclear Research Center of Birine (Algeria); Aissani, Slimane [Hydrocarbons and Chemistry Faculty, University of Boumerdes (Algeria); Bouam, Abdellah [Laboratory for Thermal-Hydraulics, Nuclear Research Center of Birine (Algeria)

    2015-11-15

    Highlights: • TransAT CMFD code application to DCC phenomenon. • LEIS methodology to predict the condensing steam flow rate. • Validation of interfacial phase-change heat transfer and turbulence models. • Correction of damping function at the free surface region. • Numerical validation of previous models using LIM and KAERI & KAIST test facilities. - Abstract: The use of CFD for the industrial studies related to PTS, including DCC is already possible; improvements of the two-phase modeling capabilities have to be undertaken to qualify the codes for the simulation of such flows. The DCC in horizontally stratified flow regime constitutes very considerable challenge exercises for a computational fluid dynamics (CFD) simulation of the thermal hydraulics PTS phenomenon because the interplay between turbulence and interfacial heat and mass transfer problem. The main purpose of our study is to investigate numerically the DCC in horizontally stratified steam water flow in a 2D and 3D channel using TransAT CMFD code. The new methodology known as Large-Eddy & Interface (LEIS) have been implemented for treatment of turbulence combined with interface tracking ITM (level set approach). Among of the so-called ‘coarse-grained’ ITM's models, the modified original surface divergence has been chosen as well as the treatment of the turbulence by URANS and VLES. This contribution addressed on the validation of interfacial phase-change heat transfer and turbulence models with special correction of the damping function at the free surface for single and combined-effect thermal hydraulic studies for LIM and KAERI & KAIST test facilities. The LIES methodology was found to apply successfully to predict the condensing steam flow rate in the all cases of the LIM test case involving a Smooth to Wavy turbulent, concurrent stratified steam-water flow in a 2D channel. The CMFD TransAT code predicting capability is analyzed, comparing the liquid temperature and to much the

  17. High Piezo-photocatalytic Efficiency of CuS/ZnO Nanowires Using Both Solar and Mechanical Energy for Degrading Organic Dye.

    Science.gov (United States)

    Hong, Deyi; Zang, Weili; Guo, Xiao; Fu, Yongming; He, Haoxuan; Sun, Jing; Xing, Lili; Liu, Baodan; Xue, Xinyu

    2016-08-24

    High piezo-photocatalytic efficiency of degrading organic pollutants has been realized from CuS/ZnO nanowires using both solar and mechanical energy. CuS/ZnO heterostructured nanowire arrays are compactly/vertically aligned on stainless steel mesh by a simple two-step wet-chemical method. The mesh-supported nanocomposites can facilitate an efficient light harvesting due to the large surface area and can also be easily removed from the treated solution. Under both solar and ultrasonic irradiation, CuS/ZnO nanowires can rapidly degrade methylene blue (MB) in aqueous solution, and the recyclability is investigated. In this process, the ultrasonic assistance can greatly enhance the photocatalytic activity. Such a performance can be attributed to the coupling of the built-in electric field of heterostructures and the piezoelectric field of ZnO nanowires. The built-in electric field of the heterostructure can effectively separate the photogenerated electrons/holes and facilitate the carrier transportation. The CuS component can improve the visible light utilization. The piezoelectric field created by ZnO nanowires can further separate the photogenerated electrons/holes through driving them to migrate along opposite directions. The present results demonstrate a new water-pollution solution in green technologies for the environmental remediation at the industrial level.

  18. Upgraded phase control system for superconducting low-velocity accelerating structures

    International Nuclear Information System (INIS)

    Added, N.

    1992-01-01

    Microphonic-induced fluctuations in the RF eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the frequency range and the RF energy content of the Rf cavity. The fast tuner for the SC resonators in the ATLAS heavy-ion linac is a voltage-controlled reactance based on an array of PIN diodes operating immersed in liquid nitrogen. This paper discusses recent upgrades to the ATLAS fast tuner which can now provide as much as 30 KVA of reactive tuning capability with a real RF power loss of less than 300 watts. The design was guided by numerical modeling of all elements of the device. Also discussed is the RF coupler which can couple 30 KW from 77 K tuner to a 42 K resonant cavity with less than 2 W of RF loss into 4.2 K

  19. Validation of the superconducting 3.9 GHz cavity package for the European X-ray Free Electron Laser

    Directory of Open Access Journals (Sweden)

    C. G. Maiano

    2017-04-01

    Full Text Available A full test of the cavity package concept under realistic operating condition was a necessary step before the assembly of the European XFEL (EXFEL 3.9 GHz superconducting system and its installation in the accelerator. One cavity, equipped with magnetic shielding, power coupler and frequency tuner has been tested in a specially designed single cavity cryostat in one of the test benches of the DESY Accelerator Module Test Facility (AMTF. The cavity was operated at high pulsed power up to an accelerating field of 24  MV/m, above the quench accelerating field of 21  MV/m achieved during the continuous wave (CW vertical qualification test and with a large margin with respect to the EXFEL maximum operating specification of 15  MV/m for the 3.9 GHz system. All subsystems under test—coupler, tuner, waveguide tuners, low level radio-frequency (LLRF system—were qualified to their design performances.

  20. Upgraded phase control system for superconducting low-velocity accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Added, N. (Sao Paulo Univ., SP (Brazil). Dept. de Fisica Nuclear); Clifft, B.E.; Shepard, K.W. (Argonne National Lab., IL (United States))

    1992-01-01

    Microphonic-induced fluctuations in the RF eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the frequency range and the RF energy content of the Rf cavity. The fast tuner for the SC resonators in the ATLAS heavy-ion linac is a voltage-controlled reactance based on an array of PIN diodes operating immersed in liquid nitrogen. This paper discusses recent upgrades to the ATLAS fast tuner which can now provide as much as 30 KVA of reactive tuning capability with a real RF power loss of less than 300 watts. The design was guided by numerical modeling of all elements of the device. Also discussed is the RF coupler which can couple 30 KW from 77 K tuner to a 42 K resonant cavity with less than 2 W of RF loss into 4.2 K.

  1. Upgraded phase control system for superconducting low-velocity accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Added, N. [Sao Paulo Univ., SP (Brazil). Dept. de Fisica Nuclear; Clifft, B.E.; Shepard, K.W. [Argonne National Lab., IL (United States)

    1992-09-01

    Microphonic-induced fluctuations in the RF eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the frequency range and the RF energy content of the Rf cavity. The fast tuner for the SC resonators in the ATLAS heavy-ion linac is a voltage-controlled reactance based on an array of PIN diodes operating immersed in liquid nitrogen. This paper discusses recent upgrades to the ATLAS fast tuner which can now provide as much as 30 KVA of reactive tuning capability with a real RF power loss of less than 300 watts. The design was guided by numerical modeling of all elements of the device. Also discussed is the RF coupler which can couple 30 KW from 77 K tuner to a 42 K resonant cavity with less than 2 W of RF loss into 4.2 K.

  2. Three dimensional finite element analysis of the influence of posterior tibial slope on the anterior cruciate ligament and knee joint forward stability.

    Science.gov (United States)

    Qi, Yong; Sun, Hongtao; Fan, Yueguang; Li, Feimeng; Wang, Yunting; Ge, Chana

    2018-03-23

    To explore the biomechanical influence of posterior tibial angle on the anterior cruciate ligament and knee joint forward stability. The left knee joint of a healthy volunteer was scanned by CT and MRI. The data were imported into Mimics software to obtain 3D models of bone, cartilage, meniscus and ligament structures, and then Geomagic software was used to modify of the image. The relative displacement between tibia and femur and the stress of ACL were recorded. ACL tension was 12.195 N in model with 2∘ PTS, 12.639 N in model with 7∘ PTS, 18.658 N in model with 12∘ PTS. the relative displacement of the tibia and femur was 2.735 mm in model with 2∘ PTS, 3.086 mm in model with 7∘ PTS, 3.881 mm in model with 12∘ PTS. In the model with 30∘ flexion, the maximum tension of ACL was 24.585 N in model with 2∘ PTS, 25.612 N in model with 7∘ PTS, 31.481 N in model with 12∘ PTS. The relative displacement of the tibia and femur was 5.590 mm in model with 2∘ PTS, 6.721 mm in model with 7∘ PTS, 6.952 mm in model with 12∘ PTS. In the 90∘ flexion models, ACL tension was 5.119 N in model with 2∘ PTS, 8.674 N in model with 7∘ PTS, 9.314 N in model with 12∘ PTS. The relative displacement of the tibia and femur was 0.276 mm in model with 2∘ PTS, 0.577 mm in model with 7∘ PTS, 0.602 mm in model with 12∘ PTS. The steeper PTS may be a risk factor in ACL injury.

  3. Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.

    Science.gov (United States)

    Piek, J; Raes, P

    1996-01-01

    We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.

  4. Development of a Hybrid Piezo Natural Rubber Piezoelectricity and Piezoresistivity Sensor with Magnetic Clusters Made by Electric and Magnetic Field Assistance and Filling with Magnetic Compound Fluid.

    Science.gov (United States)

    Shimada, Kunio; Saga, Norihiko

    2017-02-10

    Piezoelements used in robotics require large elasticity and extensibility to be installed in an artificial robot skin. However, the piezoelements used until recently are vulnerable to large forces because of the thin solid materials employed. To resolve this issue, we utilized a natural rubber and applied our proposed new method of aiding with magnetic and electric fields as well as filling with magnetic compound fluid (MCF) and doping. We have verified the piezoproperties of the resulting MCF rubber. The effect of the created magnetic clusters is featured in a new two types of multilayered structures of the piezoelement. By measuring the piezoelectricity response to pressure, the synergetic effects of the magnetic clusters, the doping and the electric polymerization on the piezoelectric effect were clarified. In addition, by examining the relation between the piezoelectricity and the piezoresistivity created in the MCF piezo element, we propose a hybrid piezoelement.

  5. Development of a Hybrid Piezo Natural Rubber Piezoelectricity and Piezoresistivity Sensor with Magnetic Clusters Made by Electric and Magnetic Field Assistance and Filling with Magnetic Compound Fluid

    Science.gov (United States)

    Shimada, Kunio; Saga, Norihiko

    2017-01-01

    Piezoelements used in robotics require large elasticity and extensibility to be installed in an artificial robot skin. However, the piezoelements used until recently are vulnerable to large forces because of the thin solid materials employed. To resolve this issue, we utilized a natural rubber and applied our proposed new method of aiding with magnetic and electric fields as well as filling with magnetic compound fluid (MCF) and doping. We have verified the piezoproperties of the resulting MCF rubber. The effect of the created magnetic clusters is featured in a new two types of multilayered structures of the piezoelement. By measuring the piezoelectricity response to pressure, the synergetic effects of the magnetic clusters, the doping and the electric polymerization on the piezoelectric effect were clarified. In addition, by examining the relation between the piezoelectricity and the piezoresistivity created in the MCF piezo element, we propose a hybrid piezoelement. PMID:28208625

  6. Development of a Hybrid Piezo Natural Rubber Piezoelectricity and Piezoresistivity Sensor with Magnetic Clusters Made by Electric and Magnetic Field Assistance and Filling with Magnetic Compound Fluid

    Directory of Open Access Journals (Sweden)

    Kunio Shimada

    2017-02-01

    Full Text Available Piezoelements used in robotics require large elasticity and extensibility to be installed in an artificial robot skin. However, the piezoelements used until recently are vulnerable to large forces because of the thin solid materials employed. To resolve this issue, we utilized a natural rubber and applied our proposed new method of aiding with magnetic and electric fields as well as filling with magnetic compound fluid (MCF and doping. We have verified the piezoproperties of the resulting MCF rubber. The effect of the created magnetic clusters is featured in a new two types of multilayered structures of the piezoelement. By measuring the piezoelectricity response to pressure, the synergetic effects of the magnetic clusters, the doping and the electric polymerization on the piezoelectric effect were clarified. In addition, by examining the relation between the piezoelectricity and the piezoresistivity created in the MCF piezo element, we propose a hybrid piezoelement.

  7. Identification of lactose phosphotransferase systems in Lactobacillus gasseri ATCC 33323 required for lactose utilization.

    Science.gov (United States)

    Francl, Alyssa L; Hoeflinger, Jennifer L; Miller, Michael J

    2012-04-01

    Improving the annotation of sugar catabolism-related genes requires functional characterization. Our objective was to identify the genes necessary for lactose utilization by Lactobacillus gasseri ATCC 33323 (NCK334). The mechanism of lactose transport in many lactobacilli is a lactose/galactose-specific permease, yet no orthologue was found in NCK334. Characterization of an EI knockout strain [EI (enzyme I) is required for phosphotransferase system transporter (PTS) function] demonstrated that L. gasseri requires PTS(s) to utilize lactose. In order to determine which PTS(s) were necessary for lactose utilization, we compared transcript expression profiles in response to lactose for the 15 complete PTSs identified in the NCK334 genome. PTS 6CB (LGAS_343) and PTS 8C (LGAS_497) were induced in the presence of lactose 107- and 53-fold, respectively. However, L. gasseri ATCC 33323 PTS 6CB, PTS 8C had a growth rate similar to that of the wild-type on semisynthetic deMan, Rogosa, Sharpe (MRS) medium with lactose. Expression profiles of L. gasseri ATCC 33323 PTS 6CB, PTS 8C in response to lactose identified PTS 9BC (LGAS_501) as 373-fold induced, whereas PTS 9BC was not induced in NCK334. Elimination of growth on lactose required the inactivation of both PTS 6CB and PTS 9BC. Among the six candidate phospho-β-galactosidase genes present in the NCK334 genome, LGAS_344 was found to be induced 156-fold in the presence of lactose. In conclusion, we have determined that: (1) NCK334 uses a PTS to import lactose; (2) PTS 6CB and PTS 8C gene expression is strongly induced by lactose; and (3) elimination of PTS 6CB and PTS 9BC is required to prevent growth on lactose.

  8. Application of radionuclide techniques in evaluation of dilated cardiomyopathy and ischemic cardiomyopathy

    International Nuclear Information System (INIS)

    Tian Yueqin; Liu Xiujie; Shi Rongfang

    2000-01-01

    Objective: To assess the clinical significance of radionuclide techniques in differentiating dilated cardiomyopathy (DCM) from ischemic cardiomyopathy (CAD-CM). Methods: 28 patients (pts) with DCM and 55 pts with CAD-CM were studied. All pts underwent 99 Tc m -MIBI myocardial perfusion SPECT and 18 F-FDG myocardial metabolic PET. 73 pts had 99 Tc m -RBC radionuclide ventriculography and 68 pts had coronary angiography. Results: 23 pts (82%) with DCM showed perfusion abnormalities with mild and not segmental distribution. 52 pts (95%) with CAD-CM showed perfusion abnormalities that distributed along the coronary vessel territories. Perfusion defects were found in 4 pts (14%) with DCM and 45 pts (82%) with CAD-CM (P<0.01). The average perfusion score was 4.5 +- 2.6 in DCM and 9.5 +- 2.9 in CAD-CM, the area of perfusion diminished uptake was significantly smaller in DCM than in CAD-CM (P < 0.001). 2 pts with DCM and 18 pts with CAD-CM had metabolic defect. The patterns of perfusion/metabolic imaging showed mismatch in most pts with CAD-CM but match in pts with DCM. The LVEF in pts with DCM and CAD-CM was decreased but no significant difference between DCM and CAD-CM was observed. The RVEF in pts with DCM was significantly lower than that in pts with CAD-CM (32.4% +- 13.9% vs 40.9% +- 15.4%, P < 0.05). Conclusions: The radionuclide techniques showed to be helpful for distinguishing DCM from CAD-CM. The discriminate analysis revealed that segmental perfusion abnormality and RVEF were the most important factors for differentiation of DCM from CAD-CM

  9. High power tests of dressed supconducting 1.3 GHz RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Hocker, A.; Harms, E.R.; Lunin, A.; Sukhanov, A.; /Fermilab

    2011-03-01

    A single-cavity test cryostat is used to conduct pulsed high power RF tests of superconducting 1.3 GHz RF cavities at 2 K. The cavities under test are welded inside individual helium vessels and are outfitted ('dressed') with a fundamental power coupler, higher-order mode couplers, magnetic shielding, a blade tuner, and piezoelectric tuners. The cavity performance is evaluated in terms of accelerating gradient, unloaded quality factor, and field emission, and the functionality of the auxiliary components is verified. Test results from the first set of dressed cavities are presented here.

  10. Novel perspectives on diagnosis and clinical significance of the post-thrombotic syndrome in children.

    Science.gov (United States)

    Jones, Sophie; Newall, Fiona; Monagle, Paul

    2016-10-01

    Given the increase in venous thromboembolic events (VTE) in children, the incidence, diagnosis and management of post thrombotic syndrome (PTS) in children is of increasing interest. Current challenges facing clinicians caring for children with VTE is the limited evidence of the long-term outcomes for this cohort; specifically the significance and potential functional impairment associated with PTS. This paper reviews the current evidence to elucidate the risk factors for PTS in children, methods for diagnosis and management of PTS in children (aged less than 18 years). Medline, Cinahl and PsycINFO database searches were undertaken using key search terms. Priority areas in need of further research are highlighted. Expert commentary: The two paediatric PTS assessment tools currently in use have been acknowledged to overcall the incidence of mild PTS in children. A PTS tool's ability to distinguish between clinically significant PTS and mild PTS is crucial. Variation in how PTS has been reported in children across the literature suggests that the real incidence of moderate and /or clinically significant PTS in children is unknown. Furthermore, evidence is lacking about the functional impairment experienced by children with clinically significant PTS and what this means for their long-term health.

  11. Study of Ender’s Nailing in Shaft Femur Fractures of Older Children

    Directory of Open Access Journals (Sweden)

    Ladani HG

    2014-12-01

    Full Text Available Background: Fractures in shaft femur in children are relatively common. Various methods of treating these fractures starting from non operative to methods like closed intramedullary nailing are at our disposal. Traditionally non operative methods are acceptable and find wide acceptance even today in very young children. However in older children certain problems are encountered like failure to control angulation and shortening, prolonged immobilization which causes very much discomfort & the overgrowth phenomenon. In view of above difficulties, closed intramedullary nailing was attempted in older children and adolescents. I have tried to study 23 cases of shaft femur fractures in older children treated by Ender’s nails. Methodology: 22 pts., out of which one having bilateral # shaft femur (total 23 #s with age ranging from 7 to 16 yrs. were studied. 3 pts. having polio limbs studied separately. Fracture was in upper third shaft femur in 5 pts., middle third in 13 pts., lower third in 3pts. & involving more than one region in 2 pts. Fracture was transverse in 6 pts., spiral in 3 pts., oblique in 12 pts.& comminuted in 2 pts.. Results: Average union time was 10 weeks except in polio pts. where it was delayed. No nonunion, no infection. Excellent hip & knee movements in almost all pts. Out of 20 pts. ( except polio pts. limb length was equal in 17 pts., one pt. was having 1 cm. lengthening & 2 pts. were having shortening ( 1cm. & 2 cm.. Conclusion: Results of this study strongly favor the use of Ender’s nailing in shaft femur fractures in older children. Second surgery of implant removal is mandatory. Closed reduction can usually be achieved if surgery is performed earlier.

  12. Box Isolation of Fibrotic Areas (BIFA): A Patient-Tailored Substrate Modification Approach for Ablation of Atrial Fibrillation.

    Science.gov (United States)

    Kottkamp, Hans; Berg, Jan; Bender, Roderich; Rieger, Andreas; Schreiber, Doreen

    2016-01-01

    Catheter ablation strategies beyond pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF) are less well defined. Increasing clinical data indicate that atrial fibrosis is a critical common left atrial (LA) substrate in AF patients (pts). We applied a new substrate modification concept according to the individual fibrotic substrate as estimated from electroanatomic voltage mapping (EAVM) in 41 pts undergoing catheter ablation of AF. First, EAVM during sinus rhythm was done in redo cases of 10 pts with paroxysmal AF despite durable PVI. Confluent low-voltage areas (LVA) were found in all pts and were targeted with circumferential isolation, so-called box isolation of fibrotic areas (BIFA). This strategy led to stable sinus rhythm in 9/10 pts and was transferred prospectively to first procedures of 31 pts with nonparoxysmal AF. In 13 pts (42%), no LVA (atrial tachycardia was achieved in 72.2% of pts and in 83.3% of pts with 1.17 procedures/patient. In approximately 40% of pts with nonparoxysmal AF, no substantial LVA were identified, and PVI alone showed high success rate. In pts with paroxysmal AF despite durable PVI and in approximately 60% of pts with nonparoxysmal AF, individually localized LVA were identified and could be targeted successfully with the BIFA strategy. © 2015 Wiley Periodicals, Inc.

  13. Alflutop in osteoarthritis therapy

    Directory of Open Access Journals (Sweden)

    G. V. Lukina

    2004-01-01

    Full Text Available Objective. To study efficacy and safety of different schemes of alflutop (AT administration in pts with osteoarthritis (OA. Material and methods 45 pts (40 womene and 5 men with knee or hip OA or nodular form of the disease were included. Mean age was 60,3± 10,0 years, mean disease duration - 8,0±6,0 years, mean duration of the last exacerbation - 5,6±5,4 months. Pts with 2 (27 pts and 3(15 pts X-ray OA stage and 2 functional class (30 pts prevailed. Pts were devided into 3 comparable groups, 15 pts in each. Pts of the group 1 received AT I ml/day intramuscularly (im during 3 weeks, group 2 pts received intra-articular (ia injections of AT 2 ml twice a week for 3 weeks and then im for 20 days. In group 3 ia (6 and im (20 injections were performed^simultaneously. During 12 months of follow up every pt received 2 appropriate courses. Results. 41 pts completed the study. AT significantly decreased joint pain at rest and at movement measured visual analog scale and WOMAC index in all groups. It also improved functional activity of pts (according to WOMAC index. Improvement according to doctor assessment was achieved after the second course in 78% of pts in group I, in 92% in group 2 and in 86% in group 3. Sonography of knee joints showed significant decrease of synovial membrane thickness (as a sign of synovitis as well as increase parts of intra-articular hyaline cartilage thickness in group 2 and 3 pts. There was no radiological progression year of follow up. Tolerability was good. The drug was stopped due to adverse events in only 3 pts (dermatitis at the site of injection-1, increase of joint pain after intra-articular injections- 2 . In 3 other pts side effects were mild, and treatmend was continued. Conclusion. Combined Im and AT administration provides anti-inflammatory, analgesic and possible chondroprotective effect in OA pts.

  14. Juvenile idiopathic arthritis outcome and prognosis according to catamnesis evaluation

    Directory of Open Access Journals (Sweden)

    O V Semenova

    2005-01-01

    Full Text Available Objective. To study outcome and prognosis in pts with juvenile idiopathic arthritis (JIA. Material and methods. 239 JIA pts with disease duration of 10 years and more were analyzed. 80 children and adolescents before 18 years old (66 girls and 14 boys were included in group 1. Arthritis clinical and laboratory activity, radiological stage and functional status according to Steinbroker and CHAQ questionnaire were assessed. 159 grown up pts (109 female and 50 male suffering from JIA from childhood were included in group 2. They were examined using Stanford Health Assessment Questionnaire (HAQ and a specially developed social status questionnaire. Results. Half pts of group 1 had recurrence of the disease during examination but activity in most cases did not exceed stage I or 2 (54% and 31% respectively. Joint destructive changes were revealed in 50% of pts. 80% of pts had radiological signs of secondary osteoarthritis. Amyloidosis was revealed in 2 from 27 pts with systemic type of JIA. 68% of pts had 1 or 2 functional class. 1/3 of pts did not have functional limitations (CHAQ=0. 13% of pts had maximal disability with CHAQ ranging from 2,1 to 3,0 (pts with polyarticular and systemic types of JIA. Most grown up pts (59% considered their health as good. Substantial part of them worked or learned. 10 pts did not worked because of the disease (1,5%. 61% of pts did not have functional limitations (HAQ=0. 32% of pts were disabled. Most of them had 3 or 2 disability degree and had possibility to work. Conclusion. Substantial part of pts with longstanding JIA have stabilization of the disease or remission. Recurrent course of the disease was characterized by decrease of activity. Most children and grown ups with longstanding disease have relatively benign functional outcome. Pts with polyarticular and systemic types of JIA require especial attention because they have maximal risk of joint destruction with severe disability.

  15. Faraday anomalous dispersion optical tuners

    Science.gov (United States)

    Wanninger, P.; Valdez, E. C.; Shay, T. M.

    1992-01-01

    Common methods for frequency stabilizing diode lasers systems employ gratings, etalons, optical electric double feedback, atomic resonance, and a Faraday cell with low magnetic field. Our method, the Faraday Anomalous Dispersion Optical Transmitter (FADOT) laser locking, is much simpler than other schemes. The FADOT uses commercial laser diodes with no antireflection coatings, an atomic Faraday cell with a single polarizer, and an output coupler to form a compound cavity. This method is vibration insensitive, thermal expansion effects are minimal, and the system has a frequency pull in range of 443.2 GHz (9A). Our technique is based on the Faraday anomalous dispersion optical filter. This method has potential applications in optical communication, remote sensing, and pumping laser excited optical filters. We present the first theoretical model for the FADOT and compare the calculations to our experimental results.

  16. Upgraded phase control system for superconducting low-velocity accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Added, N [Sao Paulo Univ., SP (Brazil); Clifft, B E; Shepard, K W [Argonne National Lab., IL (United States)

    1992-11-01

    Microphonic-induced fluctuations in the RF eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the frequency range and the RF energy content of the RF cavity. The fast tuner for the SC resonators in the ATLAS heavy-ion linac is a voltage-controlled reactance based on an array of PIN diodes operating immersed in liquid nitrogen. This paper discusses recent upgrades to the ATLAS fast tuner which can now provide as much as 30 KVA of reactive tuning capability with a real RF power loss of less than 300 watts. The design was guided by numerical modeling of all elements of the device. Also discussed is the RF coupler which can couple 30 KW from 77 K tuner to a 4.2 K resonant cavity with less than 2 W of RF loss into 4.2 K. (Author) 6 refs., 2 figs.

  17. Upgraded phase control system for superconducting low-velocity accelerating structures

    International Nuclear Information System (INIS)

    Added, N.; Clifft, B.E.; Shepard, K.W.

    1992-01-01

    Microphonic-induced fluctuations in the RF eigenfrequency of superconducting (SC) slow-wave structures must be compensated by a fast-tuning system in order to control the RF phase. The tuning system must handle a reactive power proportional to the product of the frequency range and the RF energy content of the RF cavity. The fast tuner for the SC resonators in the ATLAS heavy-ion linac is a voltage-controlled reactance based on an array of PIN diodes operating immersed in liquid nitrogen. This paper discusses recent upgrades to the ATLAS fast tuner which can now provide as much as 30 KVA of reactive tuning capability with a real RF power loss of less than 300 watts. The design was guided by numerical modeling of all elements of the device. Also discussed is the RF coupler which can couple 30 KW from 77 K tuner to a 4.2 K resonant cavity with less than 2 W of RF loss into 4.2 K. (Author) 6 refs., 2 figs

  18. Model-Based Engine Control Architecture with an Extended Kalman Filter

    Science.gov (United States)

    Csank, Jeffrey T.; Connolly, Joseph W.

    2016-01-01

    This paper discusses the design and implementation of an extended Kalman filter (EKF) for model-based engine control (MBEC). Previously proposed MBEC architectures feature an optimal tuner Kalman Filter (OTKF) to produce estimates of both unmeasured engine parameters and estimates for the health of the engine. The success of this approach relies on the accuracy of the linear model and the ability of the optimal tuner to update its tuner estimates based on only a few sensors. Advances in computer processing are making it possible to replace the piece-wise linear model, developed off-line, with an on-board nonlinear model running in real-time. This will reduce the estimation errors associated with the linearization process, and is typically referred to as an extended Kalman filter. The nonlinear extended Kalman filter approach is applied to the Commercial Modular Aero-Propulsion System Simulation 40,000 (C-MAPSS40k) and compared to the previously proposed MBEC architecture. The results show that the EKF reduces the estimation error, especially during transient operation.

  19. The Piezo Actuator-Driven Pulsed Water Jet System for Minimizing Renal Damage after Off-Clamp Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Kamiyama, Yoshihiro; Yamashita, Shinichi; Nakagawa, Atsuhiro; Fujii, Shinji; Mitsuzuka, Koji; Kaiho, Yasuhiro; Ito, Akihiro; Abe, Takaaki; Tominaga, Teiji; Arai, Yoichi

    2017-09-01

    In the setting of partial nephrectomy (PN) for renal cell carcinoma, postoperative renal dysfunction might be caused by surgical procedure. The aim of this study was to clarify the technical safety and renal damage after off-clamp laparoscopic PN (LPN) with a piezo actuator-driven pulsed water jet (ADPJ) system. Eight swine underwent off-clamp LPN with this surgical device, while off-clamp open PN was also performed with radio knife or soft coagulation. The length of the removed kidney was 40 mm, and the renal parenchyma was dissected until the renal calyx became clearly visible. The degree of renal degeneration from the resection surface was compared by Hematoxylin-Eosin staining and immunostaining for 1-methyladenosine, a sensitive marker for the ischemic tissue damage. The mRNA levels of neutrophil gelatinase-associated lipocalin (Ngal), a biomarker for acute kidney injury, were measured by quantitative real-time PCR. Off-clamp LPN with ADPJ system was successfully performed while preserving fine blood vessels and the renal calix with little bleeding. In contrast to other devices, the resection surface obtained with the ADPJ system showed only marginal degree of ischemic changes. Indeed, the expression level of Ngal mRNA was lower in the resection surface obtained with the ADPJ system than that with soft coagulation (p = 0.02). Furthermore, using the excised specimens of renal cell carcinoma, we measured the breaking strength at each site of the human kidney, suggesting the applicability of this ADPJ to clinical trials. In conclusion, off-clamp LPN with the ADPJ system could be safely performed with attenuated renal damage.

  20. Exergy-based sustainability analysis of a low power, high frequency piezo-based ultrasound reactor for rapid biodiesel production

    International Nuclear Information System (INIS)

    Aghbashlo, Mortaza; Tabatabaei, Meisam; Hosseinpour, Soleiman; Khounani, Zahra; Hosseini, Seyed Sina

    2017-01-01

    Highlights: • Piezoultrasonic-assisted biodiesel production was exergetically analyzed. • Alcohol content, sonication time, and temperature affected exergetic parameters. • 6:1 methanol/oil, 10 min sonication, and 60 °C temperature were the best conditions. • The exergetic sustainability index at the favorable conditions was found to be 11. - Abstract: In this work a thermodynamic model was developed to attain enhanced process comprehension of waste cooking oil (WCO) transesterification process in a low power, high frequency piezo-based ultrasound reactor. The reactor performance was assessed using the exergy concept to distinguish the effects of various operational variables, i.e., methanol to oil molar ratio (4:1–8:1), ultrasonic irradiation time (6–10 min), and temperature (40–60 °C) on the efficiency and sustainability factors. The exergetic efficiency of the developed reactor was found to be ranging from 98% to 99% and from 9% to 91% using the universal and functional definitions, respectively. The maximum functional exergetic efficiency as a decision making parameter, was found at 91% for methanol to oil molar ratio of 6:1, ultrasonic irradiation time of 10 min, and temperature of 60 °C. The exergetic sustainability index of the transesterification process at the selected conditions was determined at about 11. Under these conditions, the reactor efficiently converted triglycerides to methyl esters with an acceptable conversion efficiency of 97%, satisfying the ASTM standard. Overall, the outcomes of the current survey manifested that exergy analysis can be a preferred basis for decision making on the efficiency and sustainability of various biodiesel synthesizing systems.

  1. Monitoring of Postoperative Bone Healing Using Smart Trauma-Fixation Device With Integrated Self-Powered Piezo-Floating-Gate Sensors.

    Science.gov (United States)

    Borchani, Wassim; Aono, Kenji; Lajnef, Nizar; Chakrabartty, Shantanu

    2016-07-01

    Achieving better surgical outcomes in cases of traumatic bone fractures requires postoperative monitoring of changes in the growth and mechanical properties of the tissue and bones during the healing process. While current in-vivo imaging techniques can provide a snapshot of the extent of bone growth, it is unable to provide a history of the healing process, which is important if any corrective surgery is required. Monitoring the time evolution of in-vivo mechanical loads using existing technology is a challenge due to the need for continuous power while maintaining patient mobility and comfort. This paper investigates the feasibility of self-powered monitoring of the bone-healing process using our previously reported piezo-floating-gate (PFG) sensors. The sensors are directly integrated with a fixation device and operate by harvesting energy from microscale strain variations in the fixation structure. We show that the sensors can record and store the statistics of the strain evolution during the healing process for offline retrieval and analysis. Additionally, we present measurement results using a biomechanical phantom comprising of a femur fracture fixation plate; bone healing is emulated by inserting different materials, with gradually increasing elastic moduli, inside a fracture gap. The PFG sensor can effectively sense, compute, and record continuously evolving statistics of mechanical loading over a typical healing period of a bone, and the statistics could be used to differentiate between different bone-healing conditions. The proposed sensor presents a reliable objective technique to assess bone-healing progress and help decide on the removal time of the fixation device.

  2. Power enhancement of piezoelectric transformers for power supplies

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Steenstrup, Anders Resen; Zhang, Zhe

    2016-01-01

    This paper studies power enhancement of piezoelectric transformers to be used in inductorless, half-bridge, piezoelecteric-based switch mode power supplies for driving a piezo actuator motor system in a high strength magnetic environment for magnetic resonance imaging and computed tomography...... applications. A new multi element-piezo transformer solution is proposed along with a dual mode piezo transformer, providing power scaling and potentially improving the internal heat-up of a high power piezo transformer system....

  3. The Romanian National Program for Liver Transplantation - 852 Procedures in 815 Patients over 17 Years (2000-2017): A Continuous Evolution to Success.

    Science.gov (United States)

    Popescu, Irinel; Ionescu, Mihnea; Braşoveanu, Vladislav; Hrehoreţ, Doina; Copca, Narcis; Lupaşcu, Cristian; Botea, Florin; Dorobanţu, Bogdan; Alexandrescu, Sorin; Grigorie, Mihai; Matei, Emil; Zamfir, Radu; Lungu, Vasile; Tomescu, Dana; Droc, Gabriela; Ungureanu, Daniela; Fota, Ruxandra; Manga, Graţiela; Popescu, Mihai; Popa, Laura; Gheorghe, Liana; Iacob, Speranţa; Pietrăreanu, Corina; Mihailă, Mariana; Mic, Laurenţiu; Constantinescu, Sanda; Gheorghe, Cristian; Cotruta, Bogdan; Lupescu, Ioana; Grasu, Mugur; Boroş, Mirela; Dumitru, Radu; Toma, Mihai; Paslaru, Liliana; Vlad, Laura; Constantinescu, Ileana; Dima, Ileana; Herlea, Vlad; Becheanu, Gabriel; Pecheanu, Cătălin; Sasalovici, Daniela

    2017-01-01

    Background: Liver transplantation (LT) has become an established treatment for end-stage liver disease, with more than 20.000 procedures yearly worldwide. The aim of this study was to analyze the results of Romanian National Program of LT. Methods: Between April 2000 and April 2017, 817 pts received 852 LTs in Romania. Male/female ratio was 487/330, while adult/pediatric ratio was 753/64, with a mean age of 46 years (median 50 yrs; range 7 months - 68 yrs). Main LT indications were HBV cirrhosis (230 pts; 28.2%), HCC (173 pts; 21.2%), and HCV cirrhosis (137 pts; 16.8%). Waiting time and indications for LT, patient and donor demographics, graft features, surgical procedures, and short and long-term outcomes were analyzed. Results: DDLT was performed in 682 pts (83.9%): whole LT in 662 pts (81%), split LT in 16 pts (2.3%), reduced LT in 2 pts (0.2%), and domino LT in 1 pts (0.1%). LDLT was performed in 135 pts (16.5%): right hemiliver in 93 pts (11.4%), left lateral section in 28 pts (3.4%), left hemiliver in 8 pts (1%), left hemiliver with segment 1 in 4 pts (0.5%), and dual graft LDLT in 2 pts (0.2%). Overall major morbidity rate was 31.4% (268 pts), while perioperative mortality was 7.9% (65 pts). Retransplantation rate was 4.3% (35 pts): 27 whole LTs, 3 reduced LTs, 3 split LTs, and 2 LDLT. Long-term overall 1-, 3-, and 5-year estimated survival rates for patients were 87.9%, 81.5%, and 79.1%, respectively. One-, 3-, and 5-year overall mortality on waiting list also decreased significantly over time from 31.4%, 54.1% and 63.5%, to 4.4%, 13.9% and 23.6%, respectively. Conclusions: The Romanian National program for liver transplantation addresses all causes of acute and chronic liver failure or liver tumors in adults and children, using all surgical techniques, with good long-term outcome. The program constantly evolved over time, leading to decreased mortality rate on the waiting list. Celsius.

  4. [Analysis of the clinical course of disease and subsequent dialysis therapy in a group of patients with rheumatoid arthritis and end-stage renal disease].

    Science.gov (United States)

    Majdan, Maria; Stepniak, Cezary; Piotrowicz, Sebastian; Broniek, Karina; Blajer, Beata; Bednarek-Skublewska, Anna

    2005-04-01

    The chronic nephropathy is often present in pts with rheumatoid arthritis (RA). In the study the authors retrospectively analyzed the clinical course of the disease and outcomes of subsequent dialysotherapy in a group of pts with RA and end-stage renal disease ESRD. During last 5 years ESRD connected with RA was found in 10 (8 F, 2 M) pts out of 325 chronically dialyzed pts (peritoneal dialysis and hemodialysis) representing 3,1% of pts. The mean age at the initiation of dialysotherapy in these pts was 62,8 +/- 10,2 (range 46-76) years. Mean time from the diagnosis of RA to the start of dialysotherapy was 18,8 +/- 11,6 (range 5-40) years. Earlier the patients were treated with many disease modifying antirheumatic drugs (DMARDS) also with glucocorticosteroids and many nonsteroidal anti-inflammatory drugs. It means that they had rather aggressive type of RA. Amyloidosis was histological confirmed in 6 pts (4 F, 2 M). Peritoneal dialysis (PD) was the first choice therapy in 8 pts (2 on APD, 6 on CAPD). The main complication was increased incidence of peritonitis. 3 pts died on PD after 5, 9, 24 months (respectively) of CAPD treatment. 3 pts were transferred to HD after 5, 15, 18 (respectively) months of CAPD because of recurrent peritonitis. 2 pts up to date continue PD (one 12 months, the second 46 months on CAPD). In 5 pts who needed hemodialysis treatment there have been very serious problems with permanent vascular access formation. All used permanent indwelling catheters (Permcath). We concluded that: occurrence of ESRD in pts with RA was connected with aggressive type of disease. Pts with RA represent a dialysis group that is particularly prone to complications of PD (enteric peritonitis) and HD (vascular access problems). It seems to be connected with secondary vasculitis often found in pts with aggressive type of RA.

  5. Navigating the auditory scene: an expert role for the hippocampus.

    Science.gov (United States)

    Teki, Sundeep; Kumar, Sukhbinder; von Kriegstein, Katharina; Stewart, Lauren; Lyness, C Rebecca; Moore, Brian C J; Capleton, Brian; Griffiths, Timothy D

    2012-08-29

    Over a typical career piano tuners spend tens of thousands of hours exploring a specialized acoustic environment. Tuning requires accurate perception and adjustment of beats in two-note chords that serve as a navigational device to move between points in previously learned acoustic scenes. It is a two-stage process that depends on the following: first, selective listening to beats within frequency windows, and, second, the subsequent use of those beats to navigate through a complex soundscape. The neuroanatomical substrates underlying brain specialization for such fundamental organization of sound scenes are unknown. Here, we demonstrate that professional piano tuners are significantly better than controls matched for age and musical ability on a psychophysical task simulating active listening to beats within frequency windows that is based on amplitude modulation rate discrimination. Tuners show a categorical increase in gray matter volume in the right frontal operculum and right superior temporal lobe. Tuners also show a striking enhancement of gray matter volume in the anterior hippocampus, parahippocampal gyrus, and superior temporal gyrus, and an increase in white matter volume in the posterior hippocampus as a function of years of tuning experience. The relationship with gray matter volume is sensitive to years of tuning experience and starting age but not actual age or level of musicality. Our findings support a role for a core set of regions in the hippocampus and superior temporal cortex in skilled exploration of complex sound scenes in which precise sound "templates" are encoded and consolidated into memory over time in an experience-dependent manner.

  6. Enhanced piezo-humidity sensing of a Cd-ZnO nanowire nanogenerator as a self-powered/active gas sensor by coupling the piezoelectric screening effect and dopant displacement mechanism.

    Science.gov (United States)

    Yu, Binwei; Fu, Yongming; Wang, Penglei; Zhao, Yayu; Xing, Lili; Xue, Xinyu

    2015-04-28

    Highly sensitive humidity sensing has been realized from a Cd-doped ZnO nanowire (NW) nanogenerator (NG) as a self-powered/active gas sensor. The piezoelectric output of the device acts not only as a power source, but also as a response signal to the relative humidity (RH) in the environment. The response of Cd-ZnO (1 : 10) NWs reached up to 85.7 upon exposure to 70% relative humidity, much higher than that of undoped ZnO NWs. Cd dopant can increase the number of oxygen vacancies in the NWs, resulting in more adsorption sites on the surface of the NWs. Upon exposure to a humid environment, a large amount of water molecules can displace the adsorbed oxygen ions on the surface of Cd-ZnO NWs. This procedure can influence the carrier density in Cd-ZnO NWs and vary the screening effect on the piezoelectric output. Our study can stimulate a research trend on exploring composite materials for piezo-gas sensing.

  7. Hyperhomocysteinemia - an additional risk factor of thrombosis in systemic lupus erythematosus and antiphospholipid syndrome

    Directory of Open Access Journals (Sweden)

    I. E. Shirokova

    2003-01-01

    Full Text Available Objective. To assess homocystein (HC level in systemic lupus erythematosus (SLE with antiphospholipid syndrome (APS and its relation to thrombosis development and blood lipide spectrum disturbances. Material and methods. 32 pts (12 male and 20 female with mean age 36 12 years and mean disease duration 13 11 years were included. 8 pts had SLE without APS, 13 - SLE with APS and 11 - primary APS (PAPS. All pts were divided into 2 groups depending on blood HC level. 26 pts with HC level more than 12 mcg/d! were included In group 1 and 6 pts with HC level less than 12 mcg/dl - in group 2. HC level was measured with high efficacious liquid chromatography (HELC. Lipid-protein blood spectrum was assessed in all pts. Results. Elevated HC level was revealed in 26 from 32 pts: in 16 with SLE (including 12 pts with APS and in 10 with PAPS. HC concentration did not depend on APS presence, but frequence of hyperhomocysteinemia (HHC significantly associated with APS and thrombotic complications. 20 from 26 (76,9% pts with HHC had thrombosis history. Only I from 6 (16,7% pts with normal HC level had thrombosis history (exact Fisher test p=0,02. HC level did not depend on age and sex. Changes of blood lipid-protein indices were revealed in most pts. Lipid spectrum disturbances were confined largely to cholesterol elevation due to increase of atherogenic lipoproteins cholesterol. Only 22% of pts showed decrease of antiatherogenic lipoproteins concentration. Bblood lipid-protein spectrum indices did not depend on HC level. Conclusion. HHC is present in 84,6% of pts with APS (primary and secondary. In pts with APS HHC is more frequent than in pts without APS. HHC is associated with thrombotic complications. HHC and lipid-protein spectrum disturbances are independent risk factors of thrombotic complications in pts with SLE and APS.

  8. Final report on the reactor pressure vessel pressurized-thermal-shock. International comparative assessment study (RPV PTS ICAS)

    International Nuclear Information System (INIS)

    Sievers, J.; Schulz, H.; Bass, R.; Pugh, C.

    1999-10-01

    A summary of the recently completed International Comparative Assessment Study of Pressurized-Thermal-Shock in Reactor Pressure Vessels (RPV PTS ICAS) is presented here to record the results in actual and comparative fashions. Within the DFM task, where account was taken of material properties and boundary conditions, reasonable agreement was obtained in linear-elastic and elastic-plastic analysis results. Linear elastic analyses and J-estimation schemes were shown to provide conservative estimates of peak crack driving force when compared with those obtained using complex three-dimensional (3D) finite element analyses. Predictions of RT NDT generally showed less scatter than that observed in crack driving force calculations due to the fracture toughness curve used for fracture assessment in the transition temperature region. Observed scatter in some analytical results could be traced mainly to a misinterpretation of the thermal expansion coefficient data given for the cladding and base metal. Also, differences in some results could be due to a quality assurance problem related to procedures for approximating the loading data given in the Problem Statement. For the PFM task, linear-elastic solutions were again shown to be conservative with respect to elastic-plastic solutions (by a factor of 2 to 4). Scatter in solutions obtained using the same computer code was generally attributable to differences in input parameters, e.g. standard deviations for the initial value of RT NDT , as well as for nickel and copper content. In the THM task, while there was a high degree of scatter during the early part of the transient, reasonable agreement in results was obtained during the latter part of the transient. Generally, the scatter was due to differences in analytical approaches used by participants, which included correlation-based engineering methods, system codes and three-dimensional computational fluids dynamics codes. Some of the models used to simulate condensation

  9. Peak-to-average power ratio reduction in orthogonal frequency division multiplexing-based visible light communication systems using a modified partial transmit sequence technique

    Science.gov (United States)

    Liu, Yan; Deng, Honggui; Ren, Shuang; Tang, Chengying; Qian, Xuewen

    2018-01-01

    We propose an efficient partial transmit sequence technique based on genetic algorithm and peak-value optimization algorithm (GAPOA) to reduce high peak-to-average power ratio (PAPR) in visible light communication systems based on orthogonal frequency division multiplexing (VLC-OFDM). By analysis of hill-climbing algorithm's pros and cons, we propose the POA with excellent local search ability to further process the signals whose PAPR is still over the threshold after processed by genetic algorithm (GA). To verify the effectiveness of the proposed technique and algorithm, we evaluate the PAPR performance and the bit error rate (BER) performance and compare them with partial transmit sequence (PTS) technique based on GA (GA-PTS), PTS technique based on genetic and hill-climbing algorithm (GH-PTS), and PTS based on shuffled frog leaping algorithm and hill-climbing algorithm (SFLAHC-PTS). The results show that our technique and algorithm have not only better PAPR performance but also lower computational complexity and BER than GA-PTS, GH-PTS, and SFLAHC-PTS technique.

  10. Tuning of External Q And Phase for The Cavities of A Superconducting Linear Accelerator

    CERN Document Server

    Katalev, V V

    2004-01-01

    The RF power required for a certain gradient of a superconducting cavity depends on the beam current and coupling between the cavity and waveguide. The coupling with the cavity may be changed by variation of Qext. Different devices can be used to adjust Qext or phase. In this paper three stub and E-H tuners are compared and their usability for the RF power distribution system for the superconducting accelerator of the European Xray laser and the TESLA linear collider is considered. The tuners were analyzed by using the scattering matrix. Advantages and limitations of the devices are presented.

  11. Elastic MCF Rubber with Photovoltaics and Sensing on Hybrid Skin (H-Skin) for Artificial Skin by Utilizing Natural Rubber: 2nd Report on the Effect of Tension and Compression on the Hybrid Photo- and Piezo-Electricity Properties in Wet-Type Solar Cell Rubber.

    Science.gov (United States)

    Shimada, Kunio

    2018-06-06

    In contrast to ordinary solid-state solar cells, a flexible, elastic, extensible and light-weight solar cell has the potential to be extremely useful in many new engineering applications, such as in the field of robotics. Therefore, we propose a new type of artificial skin for humanoid robots with hybrid functions, which we have termed hybrid skin (H-Skin). To realize the fabrication of such a solar cell, we have continued to utilize the principles of ordinary solid-state wet-type or dye-sensitized solar rubber as a follow-up study to the first report. In the first report, we dealt with both photovoltaic- and piezo-effects for dry-type magnetic compound fluid (MCF) rubber solar cells, which were generated because the polyisoprene, oleic acid of the magnetic fluid (MF), and water served as p- and n- semiconductors. In the present report, we deal with wet-type MCF rubber solar cells by using sensitized dyes and electrolytes. Photoreactions generated through the synthesis of these components were investigated by an experiment using irradiation with visible and ultraviolet light. In addition, magnetic clusters were formed by the aggregation of Fe₃O₄ in the MF and the metal particles created the hetero-junction structure of the semiconductors. In the MCF rubber solar cell, both photo- and piezo-electricity were generated using a physical model. The effects of tension and compression on their electrical properties were evaluated. Finally, we experimentally demonstrated the effect of the distance between the electrodes of the solar cell on photoelectricity and built-in electricity.

  12. Intraoperative radiation therapy for locally advanced gynecological malignancies

    International Nuclear Information System (INIS)

    Haddock, M.G.; Petersen, I.A.; Webb, M.J.; Wilson, T.O.; Podratz, K.C.; Gunderson, L.L.

    1996-01-01

    Purpose: Evaluate disease control and survival in patients with locally advanced gynecological malignancies who received intraoperative radiation therapy with electrons (IOERT) as a component of treatment. Methods and Materials: Between March 1983 and June 1995, 63 patients (pts) with locally advanced primary (9 pts) or recurrent (54 pts) gynecological malignancies received IOERT as a component of attempted curative therapy. The site of origin was uterine cervix in 40 pts, uterine corpus in 16 pts, vagina in 5 pts, and ovary in 2 pts. Thirty-eight patients with recurrent disease had been previously irradiated (median prior RT dose 5040 cGy, range 900-8400). External beam radiotherapy (EBRT) was given to 43 of 63 pts either before or after IOERT (900-6570 cGy, median 4960 cGy). Chemotherapy was given to 21 pts prior to IOERT and following IOERT in 2 pts. IOERT doses ranged from 800 cGy to 2500 cGy with a median of 1750 cGy. The median IOERT dose was 2000 cGy in 20 patients with gross residual disease and 1500 cGy in 43 patients with microscopic residual disease. Endpoints included central control within the IOERT cone, local control, distant failure, disease free survival and overall survival. Variables evaluated for impact on disease outcome included tumor grade, primary site, prior RT, IOERT dose, EBRT dose, residual disease at time of IOERT, and use of chemotherapy. Results: Survival and disease control data are presented in the table below. There was no impact of any disease or treatment related variable on local or central failure. Pts with microscopic residual disease at the time of IOERT had significantly fewer distant metastases than pts with gross residual (5 yr 31% vs. 77%, p = 0.001) and improved survival (5 yr 37% vs. 10%, p = 0.02). Patients with recurrent disease after previous RT had survival and disease control rates which were similar to those seen in pts without priot RT. Toxicity ≥ grade 3 due to IOERT was observed in 11 pts (17%). Conclusion: A

  13. The particular prediction of normal MPI in diabetic patients

    International Nuclear Information System (INIS)

    Wu, Z.-F.; Li, S.-J.; Liu, H.-Y.; Liu, J.Z.; Li, X.F.; Cheng, Y.; Zhang, Y.W.; Wang, J.

    2007-01-01

    Full text: Objectives: To explore the prognostic value of normal SPECT MPI in diabetic pts. Methods: 1371 consecutively registered pts suspected with CAD were studied using rest SPECT MPI, and 1047 cases (76.37%) were followed up successfully. The mean interval of following up was 33.25±14.95(1∼56) months, and even longer than 18 months for pts with no cardiac events (CE). Results: Of 1047 pts, 172 were diabetic. During the follow up period, there are 42 cardiac events in 172 diabetic patients, and 86 in 857 non-diabetics. Diabetic pts had significantly higher rates of cardiac events (24.4% versus 9.8%; chi-square 28.5, P<0.0001). In the 567 pts with normal MPI, there are 4 cardiac events in 54 diabetic pts and 6 cases in 513 nondiabetic pts. The diabetic pts had significantly higher rates of cardiac events compared with the non-diabetic pts (7.41% versus 1.17%, Fisher's Exact Test, P=0.01). Conclusions: A normal SPECT has a high negative predictive value, but diabetic patients had significantly higher cardiac events rate compared with non-diabetic patients, what ever the MPI is normal or abnormal. (author)

  14. Non-Hodgkin's lymphomas in the elderly: prospective studies with specifically devised chemotherapy regimens in 66 patients.

    Science.gov (United States)

    Tirelli, U; Carbone, A; Zagonel, V; Veronesi, A; Canetta, R

    1987-05-01

    The results of 2 consecutive and prospective trials with specifically devised chemotherapy regimens in elderly patients (pts) with non-Hodgkin's lymphoma (NHL) are reported. Between August 1979 and September 1984, 66 pts aged 70 or older (median 75 years) with NHL entered 2 consecutive trials, the former with single agent teniposide 100 mg/m2 i.v. weekly (41 pts), the latter with etoposide and prednimustine (E + P), 100 mg/m p.o. for 5 days every 21 days (25 pts). Forty-five pts were previously untreated, 21 previously treated. Forty-seven pts were of the intermediate and high grade groups according to the Working Formulation; 19 pts were of the low grade; 57 pts were stages III and IV, 9 pts were stages I and II. The median performance status was 70 (range 30-100). The objective response rate in the 66 evaluable pts is 53% with 38% CR; the 3-year overall, disease-free and CR survivals are 21, 12 and 40% respectively. The objective response rate in the 45 previously untreated pts is 58% with 42% CR; the 3-year overall, disease-free and CR survivals are 24, 16 and 58% respectively. The overall toxicity was mild. Severe toxicity (grade III and IV according to WHO criteria) was observed only in 16/498 courses (3.2%), with 1 toxic death (grade IV leucopenia). We experienced the usefulness of a properly orientated clinical approach to elderly pts with NHL. We suggest that a combination regimen like E + P, suitable for oral administration, may be safely employed in a large fraction of pts with NHL.

  15. Varfarin in the complex treatment of antiphospholipid syndrome: preliminary results

    Directory of Open Access Journals (Sweden)

    T M Reshetnyak

    2003-01-01

    Full Text Available Objective. To assess efficacy and tolerance of varfarin in prophylaxis and therapy of thrombotic complications in patients with antiphospholipid syndrome (APS. Methods. 20 pts with APS (5 male and 15 female received varfarin during a year. 8 of them had primary APS (PAPS and 12 -systemic lupus erythematosus with APS (SLE+APS. 2 other pts (I with SLE+APS and I with PAPS received varfarin during the last 4 years. Nobody from 9 pts with PAPS received corticosteroids (CS. In SLE+APS pts CS dose varied from 4 to 20 mg/day and was not increased during follow up. During the study prothrombine time (PT was examined with thromboplastin ( manufactured by Renam having international sensitivity index 1,2 and international normalization relation (INR. Depending on treatment scheme APS pts were divided into 3 groups. Group 1 included 8 pts with INR<2,0, Group 2-7 with INR >3,0, group 3 - 7 pts with INR<2,0 receiving as additional treatment thrombo ASS 100 mg/day and vasonit from 600 to 1200 mg/day. Results. Two pts with INR = 1,8 had thrombosis recurrence (due to leg thrombophlebitis. There were no recurrences in other groups. 2 from 22 pts had "large" bleedings. "Small" bleedings episodes were noted in 7 from 22 pts. Largely that were subcutaneous bleedings (in 4 pts no more than 5 cm of size. Two pts receiving varfarin with INR 1,8 and 2,4 had renal colic. Conclusion. Our preliminary results prove the necessity of inclusion of varfarin in the treatment of pts with APS and thrombosis but intensive anticoagulant effect is not always desired.

  16. 131I therapy for hyperthyroidism with large goitre

    International Nuclear Information System (INIS)

    Zhang Chenggang

    2002-01-01

    Objective: This retrospective analysis is to study the effects of radioiodine in hyperthyroidism with large goitre and observe the possibility to take the place of surgery. Methods: 82 patients (pts) with hyperthyroidism including 51 female and 31 male, age ranging from 11 to 75 years old (mean 35.43 ± 12.14), were treated with 131 I. All patients presented with typical clinical and biochemical hyperthyroidism and were followed up for 3-38 months after 131 I treatment. Patients were categorized into 2 diagnostic groups: Graves disease (43 pts) and toxic multinodular goitres (39 pts). Gland weights were estimated by palpation and scintigraphy. Cold nodule had not been found in scintigraphy in all pts. The dose in mCi administered were determined according to therapeutic history, thyroid weight (g), rate of uptake 131 I, patient's symptoms and course of disease, etc. 76 pts (92.7%) had iII degree goitre. Goitre weight was stratified into 150-200 g (67 pts), 201-300 g (13 pts) and 400-500 g (2pts). 71 pts (86.6%) were given one dose of 131 I, 10 pts (12.2%) two doses, one patient had three doses. The mean first dose was 39.26 ± 19.63 mCi (14-130 mCi). The mean first μCi/g was 142.89±32.29 μCi (59-200). Results: 24 pts (29.3%) had complete remission (euthyroid), 19 pts (23.2%) had partial resolution. 39 (47.6%) pts had hypothyroidism (HP) including 8 permanent HP, 11 transient HP, 3 subclinical HP and 17 indeterminate HP. The later group had HP that could not be decided to be transient or permanent because the time of following up was less than one year. After 131 I therapy, goitres of 43 pts (52.4%) became 0 degree, 34 pts (41.5%) became I degree, 4 pts (4.9%) had II degree and only one pt still had a III degree goitre. Conclusions: 131 I therapy is a safe and effective method for treating hyperthyroidism with large goitre. If the large goitre does not have cold nodule in scintigraphy, 131 I treatment may replace surgery

  17. Gallium scans of the thorax in patients with acquired immune deficiency syndrome (AIDS): Description and utilization

    Energy Technology Data Exchange (ETDEWEB)

    Le, G.; Chen, D.C.P.; Siegel, M.E.

    1984-01-01

    The pattern of distribution of gallium uptake in the thorax was investigated in patients (pts) with AIDS. Eleven pts (ages 18-53), all active homosexual males suspected of having acute pulmonary infection were studied. Ga lung scans were performed at 24-48 and/or 72 hrs. post injection. The diagnosis of AIDS was based on appropriate clinical and laboratory findings. The Ga activity in the lung was graded from zero = background to 4+ which is > liver activity. Eight of eleven pts have positive Ga scan while seven of eleven pts had positive CXR. Six pts had both positive CXR and Ga scan. One pt had a positive Ga scan with negative CXR, and one with positive CXR and negative Ga scan. The positive Ga scans included 3 pts with 4+ diffuse uptake, two pts with 2+ diffuse uptake, two pts with 1+ diffuse uptake, and two with hilar node uptake. Three pts have focal increased uptake superimposed on diffuse uptake. Two pts with 4+ diffuse uptake had mild abnormality on their CXR. One pt with 4+ uptake in the initial scan shows decreased activity on follow-up with clinical improvement after therapy. Thus, all but two pts with positive Ga scans had diffuse lung uptake. These two patients alone had B cell immunoblastic sarcoma and oral candidiasis. The pattern of Ga lung uptake in pts with AIDS reveal that a majority of positive scans are diffuse (6/8) and the intensity may suggest more active disease than CXR (2 normal) and, thus, the study may be useful in detecting changes from atypical pulmonary infection in this population.

  18. Gallium scans of the thorax in patients with acquired immune deficiency syndrome (AIDS): Description and utilization

    International Nuclear Information System (INIS)

    Le, G.; Chen, D.C.P.; Siegel, M.E.

    1984-01-01

    The pattern of distribution of gallium uptake in the thorax was investigated in patients (pts) with AIDS. Eleven pts (ages 18-53), all active homosexual males suspected of having acute pulmonary infection were studied. Ga lung scans were performed at 24-48 and/or 72 hrs. post injection. The diagnosis of AIDS was based on appropriate clinical and laboratory findings. The Ga activity in the lung was graded from zero = background to 4+ which is > liver activity. Eight of eleven pts have positive Ga scan while seven of eleven pts had positive CXR. Six pts had both positive CXR and Ga scan. One pt had a positive Ga scan with negative CXR, and one with positive CXR and negative Ga scan. The positive Ga scans included 3 pts with 4+ diffuse uptake, two pts with 2+ diffuse uptake, two pts with 1+ diffuse uptake, and two with hilar node uptake. Three pts have focal increased uptake superimposed on diffuse uptake. Two pts with 4+ diffuse uptake had mild abnormality on their CXR. One pt with 4+ uptake in the initial scan shows decreased activity on follow-up with clinical improvement after therapy. Thus, all but two pts with positive Ga scans had diffuse lung uptake. These two patients alone had B cell immunoblastic sarcoma and oral candidiasis. The pattern of Ga lung uptake in pts with AIDS reveal that a majority of positive scans are diffuse (6/8) and the intensity may suggest more active disease than CXR (2 normal) and, thus, the study may be useful in detecting changes from atypical pulmonary infection in this population

  19. Re-irradiation after salvage mastectomy for local recurrence after a conservative treatment: a retrospective analysis of twenty patients (Nancy: 1988-2001); Re-irradiation parietale apres mastectomie de rattrapage pour recidive d'un cancer du sein apres traitement conservateur: etude retrospective sur 20 patientes (Nancy: 1988-2001)

    Energy Technology Data Exchange (ETDEWEB)

    Racadot, S.; Marchal, C.; Charra-Brunaud, C.; Peiffert, D.; Bey, P. [Centre Alexis-Vautrin, Service de Radiotherapie, 54 - Vandoeuvre-les-Nancy (France); Verhaeghe, J.L. [Centre Alexis-Vautrin, Service de Chirurgie, 54 - Vandoeuvre-les-Nancy (France)

    2003-12-01

    Purpose. - To retrospectively assess the efficacy of post-mastectomy re-irradiation for local relapse of breast cancer. Patients and methods. - Twenty patients, initially treated by conservative surgery and radiotherapy (50 Gy in 25 fractions over 5 weeks) were treated from 1998 to 2001 for a local relapse by salvage mastectomy and re-irradiation (either electron or photon beams). Mean age was 53 years (31-71). Reasons for re-irradiation were that the local relapses were inflammatory (4 pts), multifocal (5 pts), cutaneous (5 pts), involved the nipple (3 pts) or because the surgical margins (either muscle or skin) were involved (3 pts). The median dose of re-irradiation was 45 Gy (33-65) in 15 fractions over 33 days. Mean follow-up was 48 months (5-97). Results. - Fifteen patients remained free of a second local recurrence and 10 were still alive, without metastasis. Neither the dose of re-irradiation nor the irradiated surfaces were prognostic factors of local control (P = 0.877 and P = 0.424). Five patients developed radiation-induced pneumonitis without functional respiratory impairment. The incidence of pneumonitis seemed to be related to the biological dose of re-irradiation (P = 0.037). Other late complications occurred such as pigmentation changes (12 pts), telangiectasia (8 pts), chondritis (2 pts), parietal fibrosis (7 pts), rib fractures (4 pts), severe pain (11 pts) and lymphedema (2 pts). The increase in biological equivalent dose was highly statistically linked with the occurrence of disabling pain (P = 0.0123). Conclusion. - Parietal re-irradiation achieves good and lasting local control with an acceptable rate of acute complications but with a risk of disabling late sequelae such as severe pain. (author)

  20. Re-irradiation after salvage mastectomy for local recurrence after a conservative treatment: a retrospective analysis of twenty patients (Nancy: 1988-2001)

    International Nuclear Information System (INIS)

    Racadot, S.; Marchal, C.; Charra-Brunaud, C.; Peiffert, D.; Bey, P.; Verhaeghe, J.L.

    2003-01-01

    Purpose. - To retrospectively assess the efficacy of post-mastectomy re-irradiation for local relapse of breast cancer. Patients and methods. - Twenty patients, initially treated by conservative surgery and radiotherapy (50 Gy in 25 fractions over 5 weeks) were treated from 1998 to 2001 for a local relapse by salvage mastectomy and re-irradiation (either electron or photon beams). Mean age was 53 years (31-71). Reasons for re-irradiation were that the local relapses were inflammatory (4 pts), multifocal (5 pts), cutaneous (5 pts), involved the nipple (3 pts) or because the surgical margins (either muscle or skin) were involved (3 pts). The median dose of re-irradiation was 45 Gy (33-65) in 15 fractions over 33 days. Mean follow-up was 48 months (5-97). Results. - Fifteen patients remained free of a second local recurrence and 10 were still alive, without metastasis. Neither the dose of re-irradiation nor the irradiated surfaces were prognostic factors of local control (P = 0.877 and P = 0.424). Five patients developed radiation-induced pneumonitis without functional respiratory impairment. The incidence of pneumonitis seemed to be related to the biological dose of re-irradiation (P = 0.037). Other late complications occurred such as pigmentation changes (12 pts), telangiectasia (8 pts), chondritis (2 pts), parietal fibrosis (7 pts), rib fractures (4 pts), severe pain (11 pts) and lymphedema (2 pts). The increase in biological equivalent dose was highly statistically linked with the occurrence of disabling pain (P = 0.0123). Conclusion. - Parietal re-irradiation achieves good and lasting local control with an acceptable rate of acute complications but with a risk of disabling late sequelae such as severe pain. (author)

  1. Lifetime Traumatic Experiences and Disordered Eating among University Students: The Role of Posttraumatic Stress Symptoms

    Directory of Open Access Journals (Sweden)

    Vilija Malinauskiene

    2018-01-01

    Full Text Available The associations between lifetime traumatic events (TEs, posttraumatic stress (PTS symptoms, and disordered eating (DE were studied in a sample of 614 university students (mean age 20 years. An anonymous questionnaire included 32 lifetime TEs, IES-revised measured PTS symptoms, and EAT-26 evaluated DE symptoms. Statistical analyses included Pearson correlations and structural equation models (SEM with bootstrapping method. Findings reveal the prevalence of DE in 8.1% of participants, while 73.9% of students experienced at least one lifetime TE. 52.0% of students with DE had PTS symptoms (p<0.0001 and 30.8% of students with lifetime TEs had PTS symptoms (p<0.001. In SEM, direct paths from lifetime TEs to PTS symptoms (0.38, p<0.0001 and from PTS symptoms to DE (0.40, p<0.0001 were observed. The final SEM confirmed the mediating role of PTS symptoms in the path between some TEs (traffic accident and seriously injured and DE among the university students. If PTS symptoms are associated with DE, then addressing PTS symptoms in the context of DE treatment may improve treatment efficacy.

  2. The moderating role of rational beliefs in the relationship between irrational beliefs and posttraumatic stress symptomology.

    Science.gov (United States)

    Hyland, Philip; Shevlin, Mark; Adamson, Gary; Boduszek, Daniel

    2014-05-01

    Rational Emotive Behaviour Therapy (REBT) assumes that rational beliefs act as cognitive protective factors against the development of psychopathology; however little empirical evidence exists regarding the nature of the possible protective effects that they offer. The current study investigates whether rational beliefs moderate the impact of irrational beliefs on posttraumatic stress symptomology (PTS). Three hundred and thirteen active law enforcement, military, and related emergency service personnel took part in the current study. Sequential moderated multiple regression analysis was employed to investigate: (i) the direct impact of irrational beliefs on PTS; (ii) the direct impact of rational beliefs on PTS; (iii) the moderating effects of rational beliefs in the relationship between irrational beliefs and PTS. The irrational beliefs predicted by REBT theory emerged as critical predictors of PTS symptomology, in particular Depreciation beliefs. Rational beliefs (Preferences, and Acceptance beliefs) had a direct, negative impact on levels of PTS, and Acceptance beliefs moderated the impact of Catastrophizing beliefs on PTS. Irrational beliefs are important cognitive vulnerability factors in symptoms of PTS, while rational beliefs (Acceptance) appear to have a protective role in the emergence of PTS symptoms, both directly and by moderating the impact of Catastrophizing beliefs.

  3. Alflutop efficacy in chronic vertebrogenous lumbar ischialgia. A double blind placebo controlled study

    Directory of Open Access Journals (Sweden)

    O S Levin

    2004-01-01

    Full Text Available Objective. To assess efficacy and safety of intramuscular (im and paravertebral (pv alflutop injections in pts with chronic vertebrogenous lumbar ischialgia. Material and methods. 83 pts with lumbar ischialgia syndrome (44 male, 39 female aged 31 to 56 years (mean 43,1 ±5,2 years were included. Disease duration varied from I to 7 years (mean 3,5± 1,9 years, duration of the present exacerbation - from 1 to 4 months (mean 2.4±0,8 months. Vertebroneurologic diagnosis was made according to H. Hall criteria. Pts were randomized into 4 groups. 32 pts of group Al received im, 23 pts of group A2 - pv alflutop injections. 14 pts of group Bl and 14 pts of group B2 received im and pv placebo injections respectively. Treatment results were scored by the doctor. Pts assessed spine pain changes on visual analog scale. Quantitative assessment of verbal syndrome was performed with Waddle scale. Results. Im alflutop injections provided good or fair effect in 61%, pv - in 69% of pts (significantly better than placebo. Effect was evident during the first 2 weeks of treatment and persisted for 3 months after its termination. The best results were achieved in pts with facet syndrome, the worst - in spinal stenosis. Drug tolerability was good in both modes of administration.

  4. A piezo surgery with corticotomies and implant placement as part of a multidisciplinary approach to treat malocclusion disorder in an adult patient: clinical report.

    Science.gov (United States)

    Gelpi, Federico; De Santis, Daniele; Marconcini, Simone; Briguglio, Francesco; Finotti, Marco

    2015-12-01

    This clinical report illustrates a multidisciplinary approach for the rehabilitation of a young adult patient affected by a bilateral edentulous space and an anterior deep bite. The patient required orthodontics and surgical corticotomy and implantology (both performed with a piezo device). A multidisciplinary planning approach, including orthodontics, oral and periodontic surgery, and restorative dentistry, has an important role in the final outcome of treatment. In fact a dental class I occlusion has been established only on the right side. The left side could not be restored to an ideal class I relationship due to the pontic prosthesis. The original collapsed right posterior occlusion was corrected. A stable posterior occlusion was established, and the balancing interference was eliminated. Centric relation and centric occlusion were established at the same vertical dimension of occlusion. The cephalometric analysis and clinical aspect at the end of treatment showed that the patient had improvements in overbite and overjet.Multidisciplinary management, including endodontic and restorative dentistry, periodontics, corticotomy-assisted orthodontics, implants, and prosthetics, was used for a young female patient with multiple missing teeth, anterior deep bite, and a malocclusion with cant of the occlusal plane. The interaction of interdisciplinary specialties and careful treatment planning were required. The patient also benefited esthetically from our effort.

  5. Ecodopplercardiografia transesofágica intra-operatória: utilidade na cirurgia da valva mitral The usefulness of intraoperative transesofageal echocardiography for mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Álvaro Villela de Moraes

    1992-12-01

    Full Text Available A ecodopplercardiografia ocupa posição de destaque no diagnóstico das valvopatias, pois fornece dados sobre a anatomia valvar, a área estenótica, os gradientes pressóricos e o grau da regurgitação. Seu uso na cirurgia cardíaca, com a abordagem epicárdica, é bastante conhecido. O advento da abordagem transesofágica, por não interferir no campo operatório, facilitou a sua utilização. O objetivo deste trabalho foi estudar a utilidade da ETE nacirurgiada valva mitral. De julho de 1991 a janeiro de 1992, aecodopplercardiografia transesofágica (ETE monitorizou 198 cirurgias, das quais 65 foram sobre a valva mitral (VM. A idade variou de 8 a 62 anos e 42 pacientes eram do sexo feminino. A comissurotomia e papilarotomia (CP foi o procedimento mais freqüente em 28 pacientes (pts, seguido do implante de bioprótese (BP em 24 e da plastia (PL em 19. A ETE pré-operatória confirmou o diagnóstico da lesão mitral em todos os pts, tendo acrescentado informações quanto ao grau e direção da insuficiência mitral (IM em 8 dos 28 pts submetidos a CP. Modificou a orientação da abordagem da valva tricúspide em 9 oportunidades (3 por diagnosticar lesões não detectadas e 6 por evitar a abordagem desnecessária por melhor avaliação da lesão. Quanto aos pts submetidos a implante de BP, 6 já tinham próteses disfuncionantes, em 12 pts a BP foi implantada de imediato por decisão do cirurgião e, em 6 pts, a BP foi implantada após a detecção da presença de IM importante pós-correção. Quanto ao pts submetidos a PL, 12 tinham prolapso, 6 tinham insuficiência coronária e 1 era pós-operatório tardio de correção de defeito do septo atrioventricular. Em apenas 1 pt foi necessária nova CEC para nova plastia. A avaliação da tM pós CEC evidenciou 7 pts (10% com IM importante, sendo necessária nova CEC, e mostrou IM leve em 15 pts, moderada em 8 e importante em 1 onde não foi realizada nova CEC. A ETE é um método de grande

  6. Gastroduodenal safety of Nimesulid (Nimesil, Berlin Chemie in rheumatic patients with history of ulcer

    Directory of Open Access Journals (Sweden)

    A. E. Karateyev

    2003-01-01

    Full Text Available Objective. To assess safety of nimesulid in rheumatic pts with history of ulcer or multiple erosions (ME of stomach and/or duodenal mucosa. Methods. 42 pts with rheumatic diseases aged 22-73 years were included. AH had gastric or duodenal ulcers or ME (n>10 connected with NSAID treatment and confirmed by endoscopy no more than 6 months before the beginning of the study. Pts were included after healing of ulcers and erosions. The pts were randomized to receive Nimesulid 200 mg/day (group 1 or Diclofenac suppositoria 100 mg/day + ranitidine 150 mg/day (group 2. Esophagogastroduodenoscopy was performed before and 12 weeks after the beginning of treatment. Results. Relapse of stomach ulcer was observed in I pts of group 1 (5,6%. Relapse of NSAID-induced ulcers and ME was noted in 6 pts of group 2 (33,3%: in 4 cases stomach ulcers, in 1 case stomach ME, in 1 case duodenal ulcer (p=0,0424. Presence of gastralgias and dyspepsia was noted in 36,8% pts of group 1 and in 20% pts of group 2 (p=0,0539. In 1 pts of group 2 gastralgias were the reason for premature endoscopy. Conclusion. Nimesil (Nimesulid can be considered as a more safe drug than classical NSAIDs with smaller risk of serious gastroduodenal complications development in rheumatic pts with ulcer history. The results of the study allow to recommend Nimesulid as a drug of choice for treatment of pts with history of NSAID-induced gastropathy.

  7. Transurethral resection of the prostate for patients with grade III urinary symptoms following transperineal implantation of the prostate

    International Nuclear Information System (INIS)

    Potters, L; Waldbaum, R; Bosworth, J; Ashley, R

    1996-01-01

    PURPOSE/OBJECTIVE: Patients (Pts) undergoing a I-125 or Pd-103 transperineal implant of the prostate (TPIP) experience urethritis of a varying degree. Most pts with mild to moderate symptoms can be treated with alpha blocking agents. Few pts will experience urethritis that does not respond to medical management, or persists beyond three half life's of the isotope. These pts will have significant quality of life complaints related to their symptoms. The purpose of this study is to present our results of Transurethral resection of the prostate (TURP) for patients with grade III urethritis. MATERIALS AND METHODS: Between November 1992 and January 1996, 378 patients underwent TPIP for clinically localized cancer. Treatment consisted of either a Pd-103 or I-125 implant either alone or in combination with external beam radiation and/or hormones. All the implants used a peripheral loading and urethral sparing technique. All pts were followed after the implant and assessed by DRE, PSA, and symptoms. The grading of urinary symptoms was as follows: Grade I-successful relief with pyridium or an equivalent medication, Grade II-pts requiring various doses of alpha blockers, Grade III-pts with persistent symptoms despite medical management. RESULTS: Of the 378 pts undergoing implant, 358 had sufficient follow-up to be included in this review. Forty two pts (12%) received hormone downsizing prior to implantation. Two hundred and two (56%) underwent a Pd-103 implant and 156 (44%) a I-125 implant; 15 underwent EBRT plus I-125 and 27 with EBRT and Pd-103. One hundred and fifty five (43%) pts experienced grade I urethritis during the first three half life's of the implant, while 116 (32%) experienced grade II urethritis. Twenty eight pts (8%) experienced grade III urethritis that persisted beyond three half life's of the implant. All grade III pts were offered TURP and 26 elected to undergo this procedure. Of the twenty six pts undergoing TURP, 100% experienced relief of their

  8. The Management of Synchronous Bilateral Wilms Tumor: A Report from the National Wilms Tumor Study Group

    Science.gov (United States)

    Hamilton, Thomas E.; Ritchey, Michael L.; Haase, Gerald M.; Argani, Pedram; Peterson, Susan M.; Anderson, James R.; Green, Daniel M.; Shamberger, Robert C.

    2013-01-01

    Objective To provide guidelines for future trials, we reviewed the outcomes of children with synchronous bilateral Wilms tumors (BWT) treated on National Wilms Tumor Study-4 (NWTS-4). Methods NWTS-4 enrolled 3,335 patients (pts) including 188 pts with BWT (5.6%). Treatment and outcome data were collected. Results Among 188 BWT pts registered with NWTS-4, 195 kidneys in 123 patients had initial open biopsy, 44 kidneys in 31 pts had needle biopsies. Although pre-resection chemotherapy was recommended, 87 kidneys in 83 pts were managed with primary resection: Complete nephrectomy 48 in 48 pts, 31 partial/wedge nephrectomies in 27 pts, enucleations 8 in 8 pts. No initial surgery was performed in 45 kidneys in 43 pts, 5 kidneys in 3 pts not coded. Anaplasia was diagnosed after completion of the initial course of chemotherapy in 14 pts (initial surgical procedure: 9 open biopsies, 4 needle biopsies, 1 partial nephrectomy). The average number of days from the start of chemotherapy to diagnosis of anaplasia was 390 (range 44–1,925 days). Relapse or progression of disease occurred in 54 children. End stage renal failure occurred in 23 children, 6 of whom had bilateral nephrectomies. The 8 year event free survival (EFS) for BWT with favorable histology was 74%, and overall survival (OS) was 89%; while the EFS for BWT with unfavorable histology was 40%, OS was 45%. Conclusion The current analysis of patients with BWT treated on NWTS-4 shows that preservation of renal parenchyma is possible in many pts following initial preoperative chemotherapy. The incidence of end-stage renal disease remains significantly higher in children with BWT. Future studies are warranted to address the need for earlier biopsy in non-responsive tumors and earlier definitive surgery to recognize unfavorable histology in these high risk patients. PMID:21394016

  9. Streptococcus pneumoniae Cell-Wall-Localized Phosphoenolpyruvate Protein Phosphotransferase Can Function as an Adhesin: Identification of Its Host Target Molecules and Evaluation of Its Potential as a Vaccine.

    Directory of Open Access Journals (Sweden)

    Yaffa Mizrachi Nebenzahl

    Full Text Available In Streptococcus pneumonia, phosphoenolpyruvate protein phosphotransferase (PtsA is an intracellular protein of the monosaccharide phosphotransferase systems. Biochemical and immunostaining methods were applied to show that PtsA also localizes to the bacterial cell-wall. Thus, it was suspected that PtsA has functions other than its main cytoplasmic enzymatic role. Indeed, recombinant PtsA and anti-rPtsA antiserum were shown to inhibit adhesion of S. pneumoniae to cultured human lung adenocarcinoma A549 cells. Screening of a combinatorial peptide library expressed in a filamentous phage with rPtsA identified epitopes that were capable of inhibiting S. pneumoniae adhesion to A549 cells. The insert peptides in the phages were sequenced, and homologous sequences were found in human BMPER, multimerin1, protocadherin19, integrinβ4, epsin1 and collagen type VIIα1 proteins, all of which can be found in A549 cells except the latter. Six peptides, synthesized according to the homologous sequences in the human proteins, specifically bound rPtsA in the micromolar range and significantly inhibited pneumococcal adhesion in vitro to lung- and tracheal-derived cell lines. In addition, the tested peptides inhibited lung colonization after intranasal inoculation of mice with S. pneumoniae. Immunization with rPtsA protected the mice against a sublethal intranasal and a lethal intravenous pneumococcal challenge. In addition, mouse anti rPtsA antiserum reduced bacterial virulence in the intravenous inoculation mouse model. These findings showed that the surface-localized PtsA functions as an adhesin, PtsA binding peptides derived from its putative target molecules can be considered for future development of therapeutics, and rPtsA should be regarded as a candidate for vaccine development.

  10. Factors which influence quality of life in patients with non-small cell lung cancer (NSCLC): A radiation therapy oncology group study (RTOG 89-01)

    International Nuclear Information System (INIS)

    Scott, C.B.; Sause, W.T.; Johnson, D.; Dar, A.R.; Wasserman, T.H.; Rubin, P.; Khandekar, J.; Byhardt, R.B.; Taylor, S.; McDonald, A.

    1997-01-01

    Purpose: Prospectively evaluate the quality of life (QOL) of patients with NSCLC participating in a randomized phase III study conducted by the RTOG and Eastern Cooperative Oncology Group. Determine the factors which influence QOL during and post therapy. Materials and Methods: From (4(90)) to (4(94)) to 75 patients (pts) were randomized on RTOG 89-01 between a regimen containing radiation therapy (RT) versus a regimen containing surgery (S). All pts received induction vinblastine and cisplatin, followed by either S or RT and consolidation chemotherapy (CT). Pts were given the self-assessment QOL forms prior to the start of therapy, post induction CT, post RT or S, and periodically during follow-up. Two questionnaires were used: Functional Assessment of Cancer Therapy for lung cancer patients (FACT-L) and Functional Living Index-Cancer (FLIC). The FACT-L consists of 44 questions covering 6 domains (physical, social, and emotional well-being, relationship with physician, fulfilment, and lung cancer specific concerns), FLIC contains 22 questions summing to one total score. Results: 51 pts participated in the QOL endpoint, 24 were excluded: 3 pts refused, institution did not administer QOL questionnaires in 9 pts, 3 completed QOL after start of therapy, 1 institution refused to participate, 5 questionnaires were incomplete/unusable, 1 pt could not read English, and 2 were ineligible for treatment. Participation in QOL was not predicted by any pretreatment characteristic. Women had worse pretreatment QOL (p<0.005, by FLIC) and more problems with disease-related symptoms (p<0.005, by FACT) than men. Pts with KPS 90-100 had better pretreatment QOL than pts with KPS 60-80 (p<0.025, FLIC). Neither race, marital status, education level, age, prior weight loss, nor disease symptoms statistically significantly influenced pretreatment QOL. Initial QOL did not predict overall survival. FACT-L was reported on 25 pts post induction CT. Follow-up FACT-L was available on 12 pts

  11. Structural and electrochemical properties of polythiophene

    Energy Technology Data Exchange (ETDEWEB)

    Senthilkumar, B.; Thenamirtham, P. [Solid State Ionics and Energy Devices Laboratory, Department of Physics, Bharathiar University, Coimbatore 641 046 (India); Kalai Selvan, R., E-mail: selvankram@buc.edu.in [Solid State Ionics and Energy Devices Laboratory, Department of Physics, Bharathiar University, Coimbatore 641 046 (India)

    2011-08-15

    Polythiophenes (PTs) were prepared by chemical oxidative polymerization method in presence and absence of three different (cationic - CTAB, anionic - SDS and non-ionic - Triton X-100) surfactants using FeCl{sub 3} as oxidant. The prepared PTs were characterized by FT-IR, UV-Vis, XRD, SEM and cyclic voltammetry studies. The FT-IR spectra inferred the polymerization of thiophene and elucidate the corresponding functional groups of PTs. Our results on the UV-Vis spectra demonstrate the n-{pi}* electronic transition of the conjugated molecules. Further the red shift in the absorption peak confirms the longer conjugation length of PTs. The amorphous nature of the PTs was inferred from the XRD pattern. The PTs prepared with surfactant exhibited different morphology compared to PT prepared without surfactant. The specific capacitances (SC) of the prepared PTs were calculated using cyclic voltammetry technique, the PT prepared with TRITRON X-100 exhibited higher SC of 117 F/g compared to SC of surfactant free PT (78 F/g). Hence, the PTs prepared with surfactants were found to be suitable electrode materials for redox supercapacitors.

  12. Study liquid length penetration results obtained with a direct acting piezo electric injector

    International Nuclear Information System (INIS)

    Payri, Raul; Gimeno, Jaime; Bardi, Michele; Plazas, Alejandro H.

    2013-01-01

    Highlights: ► A direct acting injector capable of controlling needle lift has been used to determine liquid phase penetration. ► The influence of injection pressure, chamber density and chamber temperature have been measured. ► When needle lift is reduced the stabilized liquid length is shortened. ► The relationship between needle lift and liquid length makes needle lift as a new way to control the injection event. - Abstract: A state of the art prototype common rail injector featuring direct control of the needle by means of a piezo stack (direct acting) has been tested. Liquid phase penetration of the sprays in diesel engine-like conditions has been studied via imaging technique in a novel continuous flow test chamber that allows an accurate control on a wide range of thermodynamic conditions (up to 1000 K and 15 MPa). This state of the art injector fitted with a 7-hole nozzle, allows a fully flexible control on the nozzle needle movement, enabling various fuel injection rate typologies. The temporal evolution of the seven sprays has been studied recording movies of the injection event in evaporative conditions via Mie scattering imaging technique and using a high speed camera. The results showed a strong influence of needle position on the stabilized liquid length while the effect of the injection pressure is negligible: the decrease of the needle lift causes a pressure drop in the needle seat and thus a reduction in the effective pressure upstream of the orifices (in the nozzle sac). According to known literature the stabilized liquid-length depends mainly on effective diameter, spray cone-angle and fuel/air properties and does not depend on fuel velocity at the orifice outlet. Therefore, due to small change in the spray cone-angle, higher injection pressures give slightly lower liquid length. However, partial needle lifts has an opposite effect: when needle is partially lifted a dramatic increase of the spray cone-angle and a consequent reduction of

  13. The predictive value of markers of fibrinolysis and endothelial dysfunction in the post thrombotic syndrome. A systematic review.

    Science.gov (United States)

    Rabinovich, Anat; Cohen, Jacqueline M; Kahn, Susan R

    2014-06-01

    The post thrombotic syndrome (PTS) develops in 20-40% of deep venous thrombosis (DVT) patients. Risk factors for PTS have not been well elucidated. Identification of risk factors would facilitate individualised risk assessment for PTS. We conducted a systematic review to determine whether biomarkers of fibrinolysis or endothelial dysfunction can predict the risk for PTS among DVT patients. Studies were identified by searching the electronic databases PubMed, EMBASE, Scopus and Web of science. We included studies published between 1990 and 2013, measured biomarker levels in adult DVT patients, and reported rates of PTS development. Fourteen studies were included: 11 investigated the association between D-dimer and PTS; three examined fibrinogen; two measured von Willebrand factor; one measured plasminogen activator inhibitor-1; one assessed ADAMTS-13 (A Disintegrin and Metalloprotease with Thrombospondin type 1 repeats) and one measured factor XIII activity. Studies varied with regards to inclusion criteria, definition of PTS, time point and method of biomarker measurement. We were unable to meta-analyse results due to marked clinical heterogeneity. Descriptively, a significant association with PTS was found for D-dimer in four studies and factor XIII in one study. Further prospective research is needed to elucidate whether these markers might be useful to predict PTS development.

  14. Total pelvic exenteration: the Albert Einstein College of Medicine/Montefiore Medical Center Experience (1987 to 2003).

    Science.gov (United States)

    Goldberg, Gary L; Sukumvanich, Paniti; Einstein, Mark H; Smith, Harriet O; Anderson, Patrick S; Fields, Abbie L

    2006-05-01

    To review the trends, modifications and results of 103 consecutive total pelvic exenterations (TPE) performed at the Montefiore Medical Center and Albert Einstein College of Medicine from 1987 to 2003. All patients who underwent TPE from January 1987 to December 2003 were included. The medical record, complications, follow-up, clinical status and demographic information were entered in a database. The procedure performed, the method of urinary diversion, colonic diversion, pelvic floor support and vaginal reconstruction were documented. Surviving patients were surveyed regarding their satisfaction with the urinary diversion, the vaginal reconstruction and their sexual function since the surgery. 103 pts were identified. Indications for TPE were recurrent cancers of the cervix (95), endometrium (2), colon and rectum (5), vulva (1). Overall 5-year survival was 47%. 5-year survival for pts with recurrent cervix cancer was 48%. Six pts (6%) recurred >5 years after the TPE. 14 pts (14%) had ureteral anastomotic leaks (no difference between ileal conduit 9/65 (14%) versus 5/38 (13%) continent conduit (P = 0.92). 34 pts (89%) with continent conduits were "continent." 14 pts (17%) had wound complications. 4 pts (4%) had parastomal hernias. 5/11 (46%) pts who had a low rectal reanastomosis developed recurrence in the pelvis. 21/39 (54%) of pts with continent conduits would choose an ileal conduit if they had the option again. Long-term renal function was similar in pts with ileal and continent conduits. Mesh of any type for pelvic floor reconstruction is associated with infection and bowel/urinary fistulas. VRAM flaps for neovagina fill the pelvic dead space, reduce the risk of fistulas and 20/36 pts (55%) are sexually active. Our overall 5-year survival is encouraging, and modifications in surgical technique have improved the reconstructive phase. Low rectal anastomoses at TPE adversely affects survival. Many of our pts with continent urinary diversions would not choose

  15. Re-irradiation of adenoid cystic carcinoma: Analysis and evaluation of outcome in 52 consecutive patients treated with raster-scanned carbon ion therapy

    International Nuclear Information System (INIS)

    Jensen, Alexandra D.; Poulakis, Melanie; Nikoghosyan, Anna V.; Chaudhri, Naved; Uhl, Matthias; Münter, Marc W.; Herfarth, Klaus K.; Debus, Jürgen

    2015-01-01

    Background: Treatment of local relapse in adenoid cystic carcinoma (ACC) following prior radiation remains a challenge: without the possibility of surgical salvage patients face the choice between palliative chemotherapy and re-irradiation. Chemotherapy yields response rates around 30% and application of tumouricidal doses is difficult due to proximity of critical structures. Carbon ion therapy (C12) is a promising method to minimize side-effects and maximize re-treatment dose in this indication. We describe our initial results for re-irradiation in heavily pre-treated ACC patients. Methods: Patients treated with carbon ion therapy between 04/2010 and 05/2013 (N = 52 pts, median age: 54 a) were retrospectively evaluated regarding toxicity (NCI CTC v.4), tumour response (RECIST) and control rates. 48 pts (92.3%) received carbon ions only, 4 pts received IMRT plus C12. Results: 4 pts were treated following R1-resection, 43 pts for inoperable local relapse. Most common tumour sites were paranasal sinus (36.5%), parotid (19.2%), and base of skull (17.3%). Pts received a median dose of 51 GyE C12/63 Gy BED and cumulative dose of 128 Gy BED [67–182 Gy] after a median RT-interval of 61 months. Median target volume was 93 ml [9–618 ml]. No higher-grade (>°II) acute reactions were observed, 7 pts showed blood–brain-barrier changes (°I/II: 8 pts; °III: 2 pts), 1 pt corneal ulceration, xerophthalmia 7 pts, °IV bleeding 1 pt, tissue necrosis 2 pts, otherwise no significant late reactions. Objective response rate (CR/PR) was 56.6%. With a median follow-up of 14 months [1–39 months] local control and distant control at 1a are 70.3% and 72.6% respectively. Of the 18 pts with local relapse, 13 pts have recurred in-field, 1 pt at the field edge, 3 pts out of field, and one in the dose gradient. Conclusion: Despite high applied doses, C12 re-irradiation shows moderate side-effects, response rates even in these heavily pre-treated patients are encouraging and present a

  16. Prognostic significance of normal quantitative Tl-201 stress scintigraphy in relation to pretest likelihood of coronary artery disease

    International Nuclear Information System (INIS)

    Russo, D.J.; Russo, D.; Clements, J.; Wackers, F.

    1984-01-01

    A previous study reported an excellent prognosis and low cardiac event rate in patients(pts) with chest pain and normal quantitative T1-201 scintigraphy(SC). Such result would not be unexpected if the population under study had a predominance of pts with low pre-T1-201 likelihood(L) of significant coronary artery disease (CAD). Hence, the authors undertook telephone follow-up in pts with chest pain syndrome and normal quantitative T1-201 exercise SC, and related outcome to pretest L of CAD. Pretest L was determined by serial L analysis on the basis of: symptoms, age, sex, and exercise ECG. All pts had T1-201 SC immediately post exercise and 2 hrs later. After interpolative background correction, circumferential count and washout profiles were generated. All pts had unequivocally normal studies. Of a total of 96 pts studied in 1981-82, 20 pts were lost to follow-up. Of the remaining 76 pts, 45 were males and 31 females. The pretest L of CAD had an inverted Gaussian distribution: thirty-four pts(47%) had 66% L of CAD. Mean follow-up was 22+- 3 months. No deaths occurred. Two pts(3%) (with pretest L of 54% and 94%) had myocardial infarctions, 8 and 22 months respectively after T1-201 stress SC. One pt underwent percutaneous transluminal coronary angioplasty (PTCA) 16 months after T1-201 stress SC. These findings confirm excellent prognostic significance of normal quantitative T1-201 stress scintigraphy

  17. Atherosclerotic vessel damage in systemic lupus erythematosus and antiphospholipid syndrome in men

    Directory of Open Access Journals (Sweden)

    A. I. Iljina

    2005-01-01

    Full Text Available Objective. To study prevalence of clinical and subclinical atherosclerosis signs in men with systemic lupus erythematosus (SLE and antiphospholipid syndrome, to assess relationship between atherosclerotic vessel damage, risk factors, CRP and anti-cardiolipin antibodies (АСА Material and methods. 62 pts were included. Mean age was 35,7+11,6 years, mean disease duration - 129,3± 102 months. Traditional and related to the disease risk factors were analyzed. To reveal atherosclerotic vessel damage carotid sonographic examination was performed. Serum CRP concentration was evaluated by high sensitivity nephelometric immunoassay. IgG and IgM АСА were assessed by solid-phase immuno-enzyme assay. Results. Sonographic signs of carotid damage was revealed in 58% of pts, clinical signs of atherosclerosis - in 42%. Pts were divided into two groups according to intima-media complex thickness (IMCT. Group I included 36 pts with atherosclerotic vessel damage signs (IMCT?0,9 mm. Group 2-26 pts with IMCT<0,9 mm. Mean age at the examination, age of disease onset, disease duration, smoking frequency damage index in group I pts were higher than in group 2 pts. Mean CRP concentration in atherosclerosis group was significantly higher than in group 2 (p=0,007. 19 pts had APS signs. 43 pts did not. CRP level significantly correlated with IMCT in SLE pts with and without APS (p<0,05. Pts with atherosclerosis had higher IgG АСА level though the differences were not statistically significant. Conclusion. Men with SLE with or without APS have high risk of atherosclerosis development. CRP elevation is associated with IMCT increase.

  18. Posttraumatic stress in survivors 1 month to 19 years after an airliner emergency landing.

    Science.gov (United States)

    Arnberg, Filip K; Michel, Per-Olof; Lundin, Tom

    2015-01-01

    Posttraumatic stress (PTS) is common in survivors from life-threatening events. Little is known, however, about the course of PTS after life threat in the absence of collateral stressors (e.g., bereavement, social stigma, property loss) and there is a scarcity of studies about PTS in the long term. This study assessed the short- and long-term course of PTS, and the influence of gender, education and age on the level and course of PTS, in survivors from a non-fatal airliner emergency landing caused by engine failure at an altitude of 1 km. There were 129 persons on board. A survey including the Impact of Event Scale was distributed to 106 subjects after 1 month, 4 months, 14 months, and 25 months, and to 95 subjects after 19 years (response rates 64-83%). There were initially high levels of PTS. The majority of changes in PTS occurred from 1 to 4 months after the event. There were small changes from 4 to 25 months but further decrease in PTS thereafter. Female gender was associated with higher levels of PTS whereas gender was unrelated to the slope of the short- and long-term trajectories. Higher education was related to a quicker recovery although not to initial or long-term PTS. Age was not associated with PTS. The present findings suggest that a life-threatening experience without collateral stressors may produce high levels of acute posttraumatic stress, yet with a benign prognosis. The findings further implicate that gender is unrelated to trajectories of recovery in the context of highly similar exposure and few collateral stressors.

  19. Posttraumatic stress in survivors 1 month to 19 years after an airliner emergency landing.

    Directory of Open Access Journals (Sweden)

    Filip K Arnberg

    Full Text Available Posttraumatic stress (PTS is common in survivors from life-threatening events. Little is known, however, about the course of PTS after life threat in the absence of collateral stressors (e.g., bereavement, social stigma, property loss and there is a scarcity of studies about PTS in the long term. This study assessed the short- and long-term course of PTS, and the influence of gender, education and age on the level and course of PTS, in survivors from a non-fatal airliner emergency landing caused by engine failure at an altitude of 1 km. There were 129 persons on board. A survey including the Impact of Event Scale was distributed to 106 subjects after 1 month, 4 months, 14 months, and 25 months, and to 95 subjects after 19 years (response rates 64-83%. There were initially high levels of PTS. The majority of changes in PTS occurred from 1 to 4 months after the event. There were small changes from 4 to 25 months but further decrease in PTS thereafter. Female gender was associated with higher levels of PTS whereas gender was unrelated to the slope of the short- and long-term trajectories. Higher education was related to a quicker recovery although not to initial or long-term PTS. Age was not associated with PTS. The present findings suggest that a life-threatening experience without collateral stressors may produce high levels of acute posttraumatic stress, yet with a benign prognosis. The findings further implicate that gender is unrelated to trajectories of recovery in the context of highly similar exposure and few collateral stressors.

  20. High-dose rate intra-operative radiation therapy for local advanced and recurrent colorectal cancer

    International Nuclear Information System (INIS)

    Harrison, L.B.; Mychalczak, B.; Enker, W.; Anderson, L.; Cohen, A.E.; Minsky, B.

    1996-01-01

    In an effort to improve the local control for advanced and recurrent cancers of the rectum, we have integrated high-dose rate intra-operative radiation therapy (HDR-IORT) into the treatment program. Between 11/92 and 10/95, 47 patients (pts) were treated. There were 26 males and 21 females whose ages ranged from 30-80 (median = 62) years. There were 19 pts with primary unresectable rectal cancer, and 28 pts who were treated for recurrent rectal cancer. Histology was adenocarcinoma - 45 pts, squamous cancer - 2 pts. The range of follow-up is 1-34 months (median = 14 months). The majority of primary unresectable pts received pre-operative radiation therapy (4500-5040 cGy) with chemotherapy (5-FU with Leucovorin) 4-6 weeks later, they underwent resection + HDR-IORT (1200 cGy). For the 28 pts with recurrent cancer, the majority received surgery and HDR-IORT alone because they had received prior RT. For the pts with primary unresectable disease, actuarial 2-year local control was 77%, actuarial distant metastasis-free survival was 71%, disease free survival was 66%, and overall survival was 84%. For those pts with recurrent disease, actuarial 2-year local control rate was 65%, distant metastasis-free survival was 65%, disease free survival was 47%, and overall survival was 61%. Complications occurred in 36%. There were no cases where the anatomical distribution of disease, or technical limitations prevented the adequate delivery of HDR-IORT. We conclude that this technique was most versatile, and enabled all appropriate pts to receive IORT. The preliminary data in terms of local control are encouraging, even for the poor prognostic sub-group of pts with recurrent cancer