  1. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  2. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  3. CT and MR imaging of primary tumors of the masticator space

    International Nuclear Information System (INIS)

    Aspestrand, F.; Boysen, M.

    1992-01-01

    A retrospective study of CT and MR examinations in 14 patients with benign and malignant tumors originating in the masticator space is presented. At presentation, 12 patients revealed tumor extension to adjacent regions and spaces. Perineutral tumor spread along trigeminal nerve branches to the cavernous sinus and orbits was combined with facial pain, and/or numbness, ophthalmoplegia, and exophthalmus. Detailed analysis of tumor growth and spread, enhancement and signal features at CT and MR imaging indicated that tumor histology was, with a few exceptions, nonspecific. More extensive growth and bone destruction was noted only among malignant tumors. MR imaging was found superior to CT in delineating tumor extension due to better soft tissue contrast resolution and multiplanar imaging. Posttreatment examinations were available in 11 patients and showed long-standing regional edema of the adjacent temporal lobe and masticator muscles in 4 out of 5 patients without clinical evidence of tumor. In 6 patients, CT and MR features were found almost unchanged with only small size differences after various forms of treatment. (orig.)

  4. Helical 3D-CT images of soft tissue tumors in the hand

    Energy Technology Data Exchange (ETDEWEB)

    Otani, Kazuhiro; Kikuchi, Hiraku; Tan, Akihiro; Hamanishi, Chiaki; Tanaka, Seisuke [Kinki Univ., Osaka-Sayama (Japan). School of Medicine

    2000-02-01

    X-ray, ultrasonograph CT, MRI and angiography are used to detect tumoral lesions. Recently, helical CT has been revealed to be a useful method for the diagnosis and preoperative evaluation of soft tissue tumors, by which high quality and accurate three dimensional (3D) images can be obtained quickly. We analyzed the preoperative 3D-CT images of soft tissue tumors in the hands of 11 cases (hemangioma in 6 cases, giant cell tumor, lipoma, angiofibroma, chondrosarcoma and malignant fibro-histiocytoma in one case each). Enhanced 3D-CT clearly visualized hemangiomas and solid tumors from the surrounding tissues. The tumors could easily be observed from any direction and color-coded according to the CT number. Helical 3D-CT was thus confirmed to be useful for the diagnosis and preoperative planning by indicating the details of tumor expansion into surrounding tissues. (author)

  5. Comparison of MR imaging and CT in the evaluation of uterine tumors

    International Nuclear Information System (INIS)

    Janus, C.L.; Dottino, P.; Brodman, M.; Goodman, H.; Gendal, E.S.; Rabinowitz, J.G.

    1987-01-01

    The authors compared the usefulness of MR imaging and CT in staging uterine tumors. Forty women with known cervical carcinoma, endometrial cancer, or leiomyosarcoma underwent CT and MR imaging within 1 week prior to surgery. MR imaging was better than CT for localizing tumors to the endometrium of myometrium and in the evaluation of lymph node involvement and extension to the cervix and parametria. MR imaging, with its superior ability to demonstrate pelvic anatomy and its lack of ionizing radiation and risk from iodinated contrast media, has an important place in the staging of uterine tumors

  6. F-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor

    Directory of Open Access Journals (Sweden)

    Katsuya Mitamura

    2015-01-01

    Full Text Available Primary hepatic neuroendocrine tumors (PHNETs are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG positron emission tomography (PET and fused PET/CT images showed increased uptake in the hepatic mass. Whole-body 18F-FDG PET images showed no abnormal activity except for the liver lesion. Presence of an extrahepatic tumor was also ruled out by performing upper gastrointestinal endoscopy, total colonoscopy, and chest and abdominal CT. A posterior segmentectomy was performed, and histologic examination confirmed a neuroendocrine tumor (grade 1. The patient was followed up for about 2 years after the resection, and no extrahepatic lesions were radiologically found. Therefore, the patient was diagnosed with PHNET. To the best of our knowledge, no previous case of PHNET have been detected by 18F-FDG PET imaging.

  7. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Donat, Markus Alexander; Mehrain, Sheida; Friedrich, Klaus; Krestan, Christian; Matula, Christian; Imhof, Herwig; Czerny, Christian

    2007-01-01

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  8. Automatic lung tumor segmentation on PET/CT images using fuzzy Markov random field model.

    Science.gov (United States)

    Guo, Yu; Feng, Yuanming; Sun, Jian; Zhang, Ning; Lin, Wang; Sa, Yu; Wang, Ping

    2014-01-01

    The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  9. Automatic Lung Tumor Segmentation on PET/CT Images Using Fuzzy Markov Random Field Model

    Directory of Open Access Journals (Sweden)

    Yu Guo

    2014-01-01

    Full Text Available The combination of positron emission tomography (PET and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice’s similarity coefficient (DSC was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  10. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    International Nuclear Information System (INIS)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H.

    1998-01-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.)

  11. Contrast-enhanced helical CT of the pancreas. Optimal timing of imaging for pancreatic tumor evaluation

    International Nuclear Information System (INIS)

    Koide, Kazuki; Sekiguchi, Ryuzo

    2001-01-01

    We performed three-phase helical CT in patients suspected pancreatic tumors and investigated the optimal timing of imaging for evaluation of the pancreatic mass. The pancreatic-phase was superior in detecting pancreatic tumors, including islet cell tumors that may show strong enhancement. However, portal vein-phase imaging was also superior in 16.7% of our patients. Taking into account examination for hepatic metastasis, helical CT of any pancreatic tumor should include images obtained in the pancreatic and portal vein phases. (author)

  12. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    International Nuclear Information System (INIS)

    Chen Yang; Shi Luyao; Shu Huazhong; Luo Limin; Coatrieux, Jean-Louis; Yin Xindao; Toumoulin, Christine

    2013-01-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors. (paper)

  13. Biplane CT in sellar and parasellar tumors, (2)

    International Nuclear Information System (INIS)

    Sadamoto, Kazuhiko; Sakaki, Saburo; Matsuoka, Kenzo; Goishi, Junji; Sokabe, Takashi.

    1980-01-01

    Biplane CT images of 30 cases of sellar and parasellar tumors were studied. All 3 cases of meningioma were discovered by biplane CT (the diagnostic rate, 100%). As biplane CT could exclude partial volume effects, biplane CT images could demonstrate a fine structure and the position of parasellar or skull-base meningioma. As features of craniopharyngioma visualized on biplane CT images were variable, 7 of 9 cases of craniopharyngioma were detected by biplane CT (the diagnostic rate, 80%). When contrast enhancement on biplane CT images was marked, sometimes differencial diagnosis of craniopharyngioma and other suprasellar tumors was difficult. In all 18 cases of chromophobe adenoma, biplane CT images successfully demonstrated the location and extension of the tumors including cystic tumor (the diagnostic rate, 100%). In addition, 2 cases of giant aneurysm were presented in this study as examples of the differential diagnosis of pituitary and supraseller tumors. Biplane CT images showed mainly the location and the size of aneurysm as a mass lesion: therefore, cerebral angiography including vertebral arteriography was necessary for making an exact diagnosis of aneurysm. (Tsunoda, M)

  14. Development of an automated extraction method for liver tumors in three dimensional multiphase multislice CT images

    International Nuclear Information System (INIS)

    Nakagawa, Junya; Shimizu, Akinobu; Kobatake, Hidefumi

    2004-01-01

    This paper proposes a tumor detection method using four phase three dimensional (3D) CT images of livers, i.e. non-contrast, early, portal, and late phase images. The method extracts liver regions from the four phase images and enhances tumors in the livers using a 3D adaptive convergence index filter. Then it detects local maximum points and extracts tumor candidates by a region growing method. Subsequently several features of the candidates are measured and each candidate is classified into true tumor or normal tissue based on Mahalanobis distances. Above processes except liver region extraction are applied to four phase images, independently and four resultant images are integrated into one. We applied the proposed method to 3D abdominal CT images of ten patients obtained with multi-detector row CT scanner and confirmed that tumor detection rate was 100% without false positives, which was quite promising results. (author)

  15. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    International Nuclear Information System (INIS)

    Lu, W; Wang, J; Zhang, H

    2015-01-01

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  16. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lu, W; Wang, J; Zhang, H [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  17. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    International Nuclear Information System (INIS)

    Zhang Weidong; Li Chuanxing; Liu Qingyu; Hu Yingying; Cao Yun; Huang Jinhua

    2011-01-01

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  18. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    International Nuclear Information System (INIS)

    Jensen, Nikolaj K. G.; Stewart, Errol; Lock, Michael; Fisher, Barbara; Kozak, Roman; Chen, Jeff; Lee, Ting-Yim; Wong, Eugene

    2014-01-01

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT

  19. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Nikolaj K. G., E-mail: nkyj@regionsjaelland.dk [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Stewart, Errol [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Lock, Michael; Fisher, Barbara [Radiation Oncology, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Kozak, Roman [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Chen, Jeff [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Lee, Ting-Yim [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Wong, Eugene [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Department of Physics and Astronomy, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-05-15

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

  20. Incidental diagnosis of tumor thrombosis on FDG PET/CT imaging.

    Science.gov (United States)

    Erhamamci, S; Reyhan, M; Nursal, G N; Torun, N; Yapar, A F

    2015-01-01

    Clinical data are presented on patients with tumor thrombosis (TT) incidentally detected on FDG PET/CT imaging, as well as determining its prevalence and metabolic characteristics. Out of 12,500 consecutive PET/CT examinations of patients with malignancy, the PET/CT images of 15 patients with TT as an incidental finding were retrospectively investigated. A visual and semiquantitative analyses was performed on the PET/CT scans. An evaluation was made of the pattern of FDG uptake in the involved vessel as linear or focal via visual analyses. For the semiquantitative analyses, the metabolic activity was measured using SUVmax by drawing the region of interest at the site of the thrombosis and tumor (if any). The prevalence of occult TT was 0.12%. A total of 15 patients had various malignancies including renal (1 patient), liver (4), pancreas (2), stomach (1), colon (1), non-Hodgkin lymphoma (1), leiomyosarcoma (1), endometrial (1), ovarian (1), malign melanoma (1) and parotid (1). Nineteen vessels with TT were identified in 15 patients; three patients had more than one vessel. Various vessels were affected; the most common was the inferior vena cava (n=7) followed by the portal (n=5), renal (n=3), splenic (n=1), jugular (n=1), common iliac (n=1) and ovarian vein (n=1). The FDG uptake pattern was linear in 12 and focal in 3 patients. The mean SUVmax values in the TT and primary tumors were 8.40±4.56 and 13.77±6.80, respectively. Occult TT from various malignancies and locations was found incidentally in 0.12% of patients. Interesting cases with malign melanoma and parotid carcinoma and with TT in ovarian vein were first described by FDG PET/CT. Based on the linear FDG uptake pattern and high SUVmax value, PET/CT may accurately detect occult TT, help with the assessment of treatment response, contribute to correct tumor staging, and provide additional information on the survival rates of oncology patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All

  1. The registration accuracy analysis of different CT-MRI imaging fusion method in brain tumor

    International Nuclear Information System (INIS)

    Lu Jie; Yin Yong; Shao Qian; Zhang Zicheng; Chen Jinhu; Chen Zhaoqiu

    2010-01-01

    Objective: To find an effective CT-MRI image fusion protocol in brain tumor by analyzing the registration accuracy of different methods. Methods: The simulation CT scan and MRI T 1 WI imaging of 10 brain tumor patients obtained with same position were registered by Tris-Axes landmark ,Tris-Axes landmark + manual adjustment, mutual information and mutual information + manual adjustment method. The clinical tumor volume (CTV) were contoured on both CT and MRI images respectively. The accuracy of image fusion was assessed by the mean distance of five bone markers (d 1-5 ), central position of CTV (d CTV ) the percentage of CTV overlap (P CT-MRI ) between CT and MRI images. The difference between different methods was analyzed by Freedman M non-parameter test. Results: The difference of the means d1-5 between the Tris-Axes landmark,Tris-Axes landmark plus manual adjustment,mutual information and mutual information plus manual adjustment methods were 0.28 cm ±0.12 cm, 0.15 cm ±0.02 cm, 0.25 cm± 0.19 cm, 0.10 cm ± 0.06 cm, (M = 14.41, P = 0.002). the means d CTV were 0.59 cm ± 0.28 cm, 0.60 cm± 0.32 cm, 0.58 cm ± 0.39 cm, 0.42 cm± 0.30 cm (M = 9.72, P = 0.021), the means P CT-MRI were 0.69% ±0.18%, 0.68% ±0.16%, 0.66% ±0.17%, 0.74% ±0.14% (M =14.82, P=0.002), respectively. Conclusions: Mutual information plus manual adjustment registration method was the preferable fusion method for brain tumor patients. (authors)

  2. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  3. Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

    Science.gov (United States)

    Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko

    2015-06-01

    Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid registration into routine clinical practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  4. Missed causative tumors in diagnosing tumor-induced osteomalacia with (18)F-FDG PET/CT: a potential pitfall of standard-field imaging.

    Science.gov (United States)

    Kaneuchi, Yoichi; Hakozaki, Michiyuki; Yamada, Hitoshi; Hasegawa, Osamu; Tajino, Takahiro; Konno, Shinichi

    2016-01-01

    We describe herein two tumor-induced osteomalacia (TIO) cases for whom the causative lesions, located in their popliteal fossa, that were not identified in the standard field of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT), which usually images only the head, trunk, and proximal parts of the extremities. A 47 years old Japanese man with multiple pathological fractures due to osteomalacia, accompanied by muscle weakness, hypophosphatemia, and an elevation of alkaline phosphatase (ALP) was referred to our hospital. A (18)F-FDG PET/CT scan was performed, but no (18)F-FDG uptake was detected in the standard field of imaging. Magnetic resonance imaging revealed a small subcutaneous tumor (1.9×1.2×0.6cm) of the left posteriomedial knee, displaying uniform enhancement on gadolinium-enhanced T1-weighted fat-suppression imaging. The tumor was resected widely and diagnosed as phosphaturic mesenchymal tumor, mixed connective tissue variant (PMTMCT). The other patient was a 31 years old Japanese woman with multiple pathological fractures, hypophosphatemia and elevated of ALP and was referred to our hospital on suspicion of TIO. Although the causative lesion was not identified in the standard field of (18)F-FDG PET/CT, (18)F-FDG uptake (SUVmax 2.9) was detected on the right knee in the additional whole-body (18)F-FDG PET/CT. Magnetic resonance imaging revealed a soft-tissue tumor (6.4×4.1×2.9cm) in the right posterior knee. Following biopsy, the tumor was marginally resected, and was pathologically diagnosed as PMTMCT. Once patients are suspected to have TIO, a whole-body nuclear imaging study such as (18)F-FDG PET/CT should be performed, in order not to miss the hidden causative tumor, especially occurring in the distal extremities.

  5. Molecular imaging of neuroendocrine tumors using 68Ga-labeled peptides (Somatostatin receptor PET/CT)

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.; Hoersch, D.

    2009-01-01

    Receptor PET/CT using 68 Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The 68 Ge/ 68 Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for 68 Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the 68 Ga generator could play a similar important role for PET/CT as did the 99m Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  6. Granular Cell Tumor of the Neurohypophysis: A Case Report with Magnetic Resonance and CT Imaging Findings

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Ka Yeon; Lee, Sun Jin; Ahn, Kook Jin; Jung, So Lyung; Kim, Bum Soo [Dept. of Radiology, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Lee, Yeon Soo [Dept. of Pathology, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Jeun, Shin Soo [Dept. of Neurosurgery, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    A granular cell tumor (GCT) usually occurs as a small, solitary, nodular tumor and is more prevalent in adult females. The authors report the magnetic resonance (MR) and CT imaging findings in a 61-year-old woman with GCT of the neurohypophysis presenting with a history of reduced visual acuity in her right eye. MR images showed a suprasellar mass with an isointense signal on a T1-weighted image and an hypointense signal on a T2-weighted image. The histopathological examination revealed a granular cell tumor. In this article, the MR and CT imaging findings of GCT of the neurohypophysis with the literature reviews are discussed.

  7. Granular Cell Tumor of the Neurohypophysis: A Case Report with Magnetic Resonance and CT Imaging Findings

    International Nuclear Information System (INIS)

    Choo, Ka Yeon; Lee, Sun Jin; Ahn, Kook Jin; Jung, So Lyung; Kim, Bum Soo; Lee, Yeon Soo; Jeun, Shin Soo

    2011-01-01

    A granular cell tumor (GCT) usually occurs as a small, solitary, nodular tumor and is more prevalent in adult females. The authors report the magnetic resonance (MR) and CT imaging findings in a 61-year-old woman with GCT of the neurohypophysis presenting with a history of reduced visual acuity in her right eye. MR images showed a suprasellar mass with an isointense signal on a T1-weighted image and an hypointense signal on a T2-weighted image. The histopathological examination revealed a granular cell tumor. In this article, the MR and CT imaging findings of GCT of the neurohypophysis with the literature reviews are discussed.

  8. Improved automated production of 18F-FMISO and its tumor hypoxia imaging by Micro-PET/CT

    International Nuclear Information System (INIS)

    Wang Mingwei; Zhang Yongping; Zheng Yujia; Bao Xiao; Zheng Yingjian

    2013-01-01

    Background: 1-H-1-(3-[ 18 F]fluoro-2-hydroxypropyl)-2-nitroimidazole ( 18 F-FMISO) is a specific molecular imaging probe for tumor hypoxia imaging, and its PET/CT imaging has an important clinical value for planning cancer radiotherapy target volume. Purpose: This study aimed to develop an improved, automated production of 18 F-FMISO and to perform Micro-PET/CT imaging of tumor hypoxia. Methods: Based on the labeling precursor NITTP and a simple 'one-pot' method, an upgraded Explora GN module together with Explora LC was adopted to run radiofluorination (NITTP (10 mg), MeCN (1.0 mL), 120℃, 5.0 min), hydrolysis (HCI (1.0 mol/L, 1.0 mL), 130℃, 8.0 min) and high performance liquid chromatography (HPLC) purification to produce 18 F-FMISO automatically. Moreover, Radio-HPLC and Radio-TLC were applied for the quality control, and Micro-PET/CT scanner for hypoxia imaging of SW1990 pancreatic tumor-bearing mice. Results: As results, 18 F-FMISO was obtained with the synthesis time for about 65 min, the radiochemical yield of (30±5.0)% (no decay corrected, n=20), the radiochemical purity of above 99%, the specific activity of (2.04±0.17)x10 11 Bq·μmol -1 , plus with the enhanced chemical purity. Moreover, MicroPET/CT imaging showed that 18 F-FMISO presented whole-body distribution in SW1990 tumor-bearing mice, and the optimized time point for tumor hypoxia imaging was 3 h post injection with the uptake ratios of tumor-to-muscle of 3.00±0.08. Conclusion: In sum, we developed an improved, automated production of 18 F-FMISO with high performance liquid chromatography purification, high radiochemical yield, high specific activity and high reliability , and also verified its MicroPET/CT imaging of tumor hypoxia for providing experimental reference data. (authors)

  9. Clinical evaluation of high-resolution CT, 1. CT diagnosis of liver tumors and its limit

    Energy Technology Data Exchange (ETDEWEB)

    Araki, T [Tokyo Univ. (Japan). Faculty of Medicine

    1980-03-01

    To estimate diagnostic accuracy of CT in liver tumors, CT diagnosis in 120 patients with primary hepatocellular carcinoma was discussed. As a result, primary hepatocellular carcinoma less than 2 cm in diameter could not be visualized by CT. Even tumors between 4 and 8 cm in diameter showed false negative caused by isodense tumors on images of 4 patients. To improve the detectability of liver tumors by CT, the higher resolution of low contrast regions on images are required. As a method to improve qualitative diagnosis of liver tumors, rapid intravenous injection of contrast medium was performed on 42 patients with liver tumors, As a result, images reflecting vascularity of tumors were obtained, and the differential diagnosis was possible to some extent by observing the movement of the contrast. Especially, cavernous hemangioma could be distinguished from hepatocellular carcinoma, because cavernous hemangioma showed specific images and could be diagnosed accurately.

  10. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  11. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  12. 68Ga DOTA-TATE PET/CT allows tumor localization in patients with tumor-induced osteomalacia but negative 111In-octreotide SPECT/CT.

    Science.gov (United States)

    Breer, Stefan; Brunkhorst, Thomas; Beil, F Timo; Peldschus, Kersten; Heiland, Max; Klutmann, Susanne; Barvencik, Florian; Zustin, Jozef; Gratz, Klaus-Friedrich; Amling, Michael

    2014-07-01

    Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by renal phosphate wasting, hypophosphatemia and low calcitriol levels as well as clinical symptoms like diffuse bone and muscle pain, fatigue fractures or increased fracture risk. Conventional imaging methods, however, often fail to detect the small tumors. Lately, tumor localization clearly improved by somatostatin-receptor (SSTR) imaging, such as octreotide scintigraphy or octreotide SPECT/CT. However, recent studies revealed that still a large number of tumors remained undetected by octreotide imaging. Hence, studies focused on different SSTR imaging methods such as 68Ga DOTA-NOC, 68Ga DOTA-TOC and 68Ga DOTA-TATE PET/CT with promising first results. Studies comparing different SSTR imaging methods for tumor localization in TIO are rare and thus little is known about diagnostic alternatives once a particular method failed to detect a tumor in patients with TIO. Here, we report the data of 5 consecutive patients suffering from TIO, who underwent both 111Indium-octreotide scintigraphy (111In-OCT) SPECT/CT as well as 68Ga DOTA-TATE PET/CT for tumor detection. While 111In-OCT SPECT/CT allowed tumor detection in only 1 of 5 patients, 68Ga DOTA-TATE PET/CT was able to localize the tumor in all patients. Afterwards, anatomical imaging of the region of interest was performed with CT and MRI. Thus, successful surgical resection of the tumor was achieved in all patients. Serum phosphate levels returned to normal and all patients reported relief of symptoms within weeks. Moreover, an iliac crest biopsy was obtained from every patient and revealed marked osteomalacia in all cases. Follow-up DXA revealed an increase in BMD of up to 34.5% 1-year postoperative, indicating remineralization. No recurrence was observed. In conclusion our data indicates that 68Ga DOTA-TATE PET/CT is an effective and promising diagnostic tool in the diagnosis of TIO, even in patients in whom 111In-OCT prior failed to detect

  13. Availability of perfluoroctylbromide (PFOB) emulsion used as agent in the liver tumor imaging of computed tomography (CT)

    International Nuclear Information System (INIS)

    Ozawa, Takachika

    1986-01-01

    We carried out a fundamental study on the availability of perfluoroctylbromide (PFOB) emulsion used as an agent in the liver tumor imaging of computed tomography (CT). For this study, we used emulsified yolk phospolipid as a surfactant for PFOB emulsion because it is generally considered to have higher safety relative to the administration to the humans. In the rabbits' liver tumor model in which VX 2 tumor cell was implanted into their livers, we observed increases in the CT values of the livers when 5 to 10 ml/kg of PFOB emulsion (20 % w/v) was administered into the vein, and also ringlike enhancement and increases in the CT values on the tumor rim when 20 ml/kg of PFOB emulsion was administered. In addition, in the chemical analysis of a gas chromatography, we also observed significant increases in the PFOB concentration on the tumor rim, compared with those of normal liver parenchyma, when 20 ml/kg of PFOB emulsion was given. In the finding of CT values in the human liver tumor by means of organ perfusion system, we recognized increases in the CT values (induced by the accumulation of PFOB emulsion) on the rim of the metastatic tumor of colon cancer. These results suggest that PFOB emulsion has certain availability as an agent for the liver tumor imaging of computed tomography (CT). (author)

  14. Quantitative characterization of liver tumor radiodensity in CT images: a phantom study between two scanners

    Science.gov (United States)

    Berman, Benjamin Paul; Li, Qin; McKenney, Sarah; Fricke, Stanley Thomas; Fang, Yuan; Gavrielides, Marios A.; Petrick, Nicholas

    2018-02-01

    Quantitative assessment of tumor radiodensity is important for the clinical evaluation of contrast enhancement and treatment response, as well as for the extraction of texture-related features for image analysis or radiomics. Radiodensity estimation, Hounsfield Units (HU) in CT images, can be affected by patient factors such as tumor size, and by system factors such as acquisition and reconstruction protocols. In this project, we quantified the measurability of liver tumor HU using a 3D-printed phantom, imaged with two CT systems: Siemens Somatom Force and GE Lightspeed VCT. The phantom was printed by dithering two materials to create spherical tumors (10, 14 mm) with uniform densities (90, 95, 100, 105 HU). Image datasets were acquired at 120 kVp including 15 repeats using two matching exposures across the CT systems, and reconstructed using comparable algorithms. The radiodensity of each tumor was measured using an automated matched-filter method. We assessed the performance of each protocol using the area under the ROC curve (AUC) as the metric for distinguishing between tumors with different radiodensities. The AUC ranged from 0.8 to 1.0 and was affected by tumor size, radiodensity, and scanner; the lowest AUC values corresponded to low dose measurements of 10 mm tumors with less than 5 HU difference. The two scanners exhibited similar performance >0.9 AUC for large lesions with contrast above 7 HU, though differences were observed for the smallest and lowest contrast tumors. These results show that HU estimation should be carefully examined, considering that uncertainty in the tumor radiodensity may propagate to quantification of other characteristics, such as size and texture.

  15. Computer-aided analysis of CT images for the differentiation of cerebral tumors

    International Nuclear Information System (INIS)

    Michalik, M.; Michalik, S.; Bornholdt, F.

    1988-01-01

    For the integration of CT imaging into the differential diagnostics of intracranial space occupations, the selection and description of characteristics facilitating a good discrimination of serveral classes of tumors becomes a very important task. From images of 93 patients with the most frequent brain tumors the optimal set of characteristics was determined. The four most significant characteristics for the differentiation of brain tumors are 'uptake of contrast medium by the tumor', 'deliniation of the tumor contours', 'progression of the tumor' and the 'average tumor density after administration of contrast media'. Very good results were obtained for the differentiation of menigneomas with and without anaplasia and for the differentiation of meningeomas from all other tumors examined. The differentiation of the degree of malignancy for various gliomatous tumors was difficult. An accurate reclassification with the computer program was obtained for 83.4% of all tumors. (author)

  16. Imaging of lung metastasis tumor mouse model using [{sup 18}F]FDG small animal PET and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Youp; Woo, Sang Keun; Lee, Tae Sup [Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)] (and others)

    2007-02-15

    The purpose of this study is to image metastaic lung melanoma model with optimal pre-conditions for animal handling by using [{sup 18}F]FDG small animal PET and clinical CT. The pre-conditions for lung region tumor imaging were 16-22 h fasting and warming temperature at 30 .deg. C. Small animal PET image was obtained at 60 min postinjection of 7.4 MBq [{sup 18}F]FDG and compared pattern of [{sup 18}F]FDG uptake and glucose standard uptake value (SUVG) of lung region between Ketamine/Xylazine (Ke/Xy) and Isoflurane (Iso) anesthetized group in normal mice. Metastasis tumor mouse model to lung was established by intravenous injection of B16-F10 cells in C57BL/6 mice. In lung metastasis tumor model, [{sup 18}F]FDG image was obtained and fused with anatomical clinical CT image. Average blood glucose concentration in normal mice were 128.0 {+-} 22.87 and 86.0 {+-} 21.65 mg/dL in Ke/Xy group and Iso group, respectively. Ke/Xy group showed 1.5 fold higher blood glucose concentration than Iso group. Lung to Background ratio (L/B) in SUVG image was 8.6 {+-} 0.48 and 12.1 {+-}0.63 in Ke/Xy group and Iso group, respectively. In tumor detection in lung region, [{sup 18}F]FDG image of Iso group was better than that of Ke/Xy group, because of high L/B ratio. Metastatic tumor location in [{sup 18}F]FDG small animal PET image was confirmed by fusion image using clinical CT. Tumor imaging in small animal lung region with [{sup 18}F]FDG small animal PET should be considered pre-conditions which fasting, warming and an anesthesia during [{sup 18}F]FDG uptake. Fused imaging with small animal PET and CT image could be useful for the detection of metastatic tumor in lung region.

  17. 18F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    International Nuclear Information System (INIS)

    London, Kevin; Stege, Claudia; Kaspers, Gertjan; Cross, Siobhan; Dalla-Pozza, Luciano; Onikul, Ella; Graf, Nicole; Howman-Giles, Robert

    2012-01-01

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV max and greater SUV max reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  18. Comparison of the sensitivity and specificity of CT and MR imaging in the detection of cervical nodal tumor necrosis and extracapsular tumor spread

    International Nuclear Information System (INIS)

    Yousem, D.M.; Som, P.M.; Schjwaibold, F.; Hendrix, R.

    1991-01-01

    This paper evaluates if MR imaging can achieve the sensitivity and specificity of enhanced CT in detecting tumoral nodal necrosis (TNN) and extracapsular tumor spread (ETS). Enhanced CT scans and unenhanced and enhanced MR images were retrospectively and separately reviewed by a study-blinded radiologist. Fifty-eight lymph nodes were evaluated for TNN and ETS. Readings were given for CT, T1-weighted MR, T2-weighted MR, T1-weighted and T2-weighted MR, enhanced T1-weighted fat-suppressed MR, and T1-weighted, T2-weighted, and enhanced fat suppressed T1-weighted MR. Pathology proof was used to assess TNN; CT and used to assess ETS. Enhanced CT had the highest sensitivity for TNN. The sensitivity of unenhanced MR ranged from 33% to 50%; that of enhanced MR was 47%. All MR sequences and cT had specificities for TNN >92%. The highest accuracy of MR for TNN was the unenhanced T1-weighted and T2-weighted images alone; CT accuracy was 90%. MR sensitivity for ETS was maximal with T1-weighted images; all sequences had specificities >90%. Gadolinium-enhanced images did not improve accuracy in TNN or ETS

  19. New method for extracting tumors in PET/CT images based on the probability distribution

    International Nuclear Information System (INIS)

    Nitta, Shuhei; Hontani, Hidekata; Hukami, Tadanori

    2006-01-01

    In this report, we propose a method for extracting tumors from PET/CT images by referring to the probability distribution of pixel values in the PET image. In the proposed method, first, the organs that normally take up fluorodeoxyglucose (FDG) (e.g., the liver, kidneys, and brain) are extracted. Then, the tumors are extracted from the images. The distribution of pixel values in PET images differs in each region of the body. Therefore, the threshold for detecting tumors is adaptively determined by referring to the distribution. We applied the proposed method to 37 cases and evaluated its performance. This report also presents the results of experiments comparing the proposed method and another method in which the pixel values are normalized for extracting tumors. (author)

  20. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  1. Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer

    Directory of Open Access Journals (Sweden)

    Knopp Michael V

    2007-12-01

    Full Text Available Abstract Background 18F-fluorodeoxyglucose (18F-FDG positron emission tomography/computed tomography (PET/CT has become an established method for detecting hypermetabolic sites of known and occult disease and is widely used in oncology surgical planning. Intraoperatively, it is often difficult to localize tumors and verify complete resection of tumors that have been previously detected on diagnostic PET/CT at the time of the original evaluation of the cancer patient. Therefore, we propose an innovative approach for intraoperative tumor localization and verification of complete tumor resection utilizing 18F-FDG for perioperative PET/CT imaging and intraoperative gamma probe detection. Methods Two breast cancer patients were evaluated. 18F-FDG was administered and PET/CT was acquired immediately prior to surgery. Intraoperatively, tumors were localized and resected with the assistance of a handheld gamma probe. Resected tumors were scanned with specimen PET/CT prior to pathologic processing. Shortly after the surgical procedure, patients were re-imaged with PET/CT utilizing the same preoperatively administered 18F-FDG dose. Results One patient had primary carcinoma of breast and a metastatic axillary lymph node. The second patient had a solitary metastatic liver lesion. In both cases, preoperative PET/CT verified these findings and demonstrated no additional suspicious hypermetabolic lesions. Furthermore, intraoperative gamma probe detection, specimen PET/CT, and postoperative PET/CT verified complete resection of the hypermetabolic lesions. Conclusion Immediate preoperative and postoperative PET/CT imaging, utilizing the same 18F-FDG injection dose, is feasible and image quality is acceptable. Such perioperative PET/CT imaging, along with intraoperative gamma probe detection and specimen PET/CT, can be used to verify complete tumor resection. This innovative approach demonstrates promise for assisting the oncologic surgeon in localizing and

  2. {sup 18}F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    London, Kevin [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Paediatrics and Child Health, Sydney Medical School, Sydney, NSW (Australia); Stege, Claudia; Kaspers, Gertjan [VU Medical Centre, Divisions of Paediatric Oncology/Haematology, Amsterdam (Netherlands); Cross, Siobhan; Dalla-Pozza, Luciano [The Children' s Hospital at Westmead, Department of Oncology, Sydney (Australia); Onikul, Ella [The Children' s Hospital at Westmead, Department of Medical Imaging, Sydney (Australia); Graf, Nicole [The Children' s Hospital at Westmead, Department of Pathology, Sydney (Australia); Howman-Giles, Robert [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Imaging, Sydney Medical School, Sydney, NSW (Australia)

    2012-04-15

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV{sub max} and greater SUV{sub max} reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  3. Thymic epithelial tumors: Comparison of CT and MR imaging findings of low-risk thymomas, high-risk thymomas, and thymic carcinomas

    International Nuclear Information System (INIS)

    Sadohara, Junko; Fujimoto, Kiminori; Mueller, Nestor L.; Kato, Seiya; Takamori, Shinzo; Ohkuma, Kazuaki; Terasaki, Hiroshi; Hayabuchi, Naofumi

    2006-01-01

    Objective: To assess the CT and magnetic resonance (MR) imaging findings of thymic epithelial tumors classified according to the current World Health Organization (WHO) histologic classification and to determine useful findings in differentiating the main subtypes. Materials and methods: Sixty patients with thymic epithelial tumor who underwent both CT and MR imaging were reviewed retrospectively. All cases were classified according to the 2004 WHO classification. The following findings were assessed in each case on both CT and MRI: size of tumor, contour, perimeter of capsule; homogeneity, presence of septum, hemorrhage, necrotic or cystic component within tumor; presence of mediastinal lymphadenopathy, pleural effusion, and great vessel invasion. These imaging characteristics of 30 low-risk thymomas (4 type A, 12 type AB, and 14 type B1), 18 high-risk thymomas (11 type B2 and seven type B3), and 12 thymic carcinomas on CT and MR imaging were compared using the chi-square test. Comparison between CT and MR findings was performed by using McNemar test. Results: On both CT and MR imaging, thymic carcinomas were more likely to have irregular contours (P < .001), necrotic or cystic component (P < .05), heterogeneous contrast-enhancement (P < .05), lymphadenopathy (P < .0001), and great vessel invasion (P < .001) than low-risk and high-risk thymomas. On MR imaging, the findings of almost complete capsule, septum, and homogenous enhancement were more commonly seen in low-risk thymomas than high-risk thymomas and thymic carcinomas (P < .05). MR imaging was superior to CT in the depiction of capsule, septum, or hemorrhage within tumor (all comparison, P < .05). Conclusion: The presence of irregular contour, necrotic or cystic component, heterogeneous enhancement, lymphadenopathy, and great vessel invasion on CT or MR imaging are strongly suggestive of thymic carcinomas. On MR imaging, the findings of contour, capsule, septum, and homogenous enhancement are helpful in

  4. Segmentation of liver tumors on CT images

    International Nuclear Information System (INIS)

    Pescia, D.

    2011-01-01

    This thesis is dedicated to 3D segmentation of liver tumors in CT images. This is a task of great clinical interest since it allows physicians benefiting from reproducible and reliable methods for segmenting such lesions. Accurate segmentation would indeed help them during the evaluation of the lesions, the choice of treatment and treatment planning. Such a complex segmentation task should cope with three main scientific challenges: (i) the highly variable shape of the structures being sought, (ii) their similarity of appearance compared with their surrounding medium and finally (iii) the low signal to noise ratio being observed in these images. This problem is addressed in a clinical context through a two step approach, consisting of the segmentation of the entire liver envelope, before segmenting the tumors which are present within the envelope. We begin by proposing an atlas-based approach for computing pathological liver envelopes. Initially images are pre-processed to compute the envelopes that wrap around binary masks in an attempt to obtain liver envelopes from estimated segmentation of healthy liver parenchyma. A new statistical atlas is then introduced and used to segmentation through its diffeomorphic registration to the new image. This segmentation is achieved through the combination of image matching costs as well as spatial and appearance prior using a multi-scale approach with MRF. The second step of our approach is dedicated to lesions segmentation contained within the envelopes using a combination of machine learning techniques and graph based methods. First, an appropriate feature space is considered that involves texture descriptors being determined through filtering using various scales and orientations. Then, state of the art machine learning techniques are used to determine the most relevant features, as well as the hyper plane that separates the feature space of tumoral voxels to the ones corresponding to healthy tissues. Segmentation is then

  5. CT and MR imaging findings of endocrine tumor of the pancreas according to WHO classification

    International Nuclear Information System (INIS)

    Rha, Sung Eun; Jung, Seung Eun; Lee, Kang Hoon; Ku, Young Mi; Byun, Jae Young; Lee, Jae Mun

    2007-01-01

    The pancreatic endocrine tumors are rare neuroendocrine tumors of the pancreas originating from totipotential stem cells or differentiated mature endocrine cells within the exocrine gland. Endocrine tumors are usually classified into functioning and non-functioning tumors and presents with a range of benignity or malignancy. In this article, we present the various CT and MR imaging findings of endocrine tumors of pancreas according to recent WHO classification

  6. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C

  7. Warthin's Tumor of the Parotid Gland: CT and MR Features

    International Nuclear Information System (INIS)

    Lee, Yun Hee; Yu, In Kyu; Lee, Byung Hee; Kim, Min Sun; Han, Moon Hee; Song, Chang Joon

    2009-01-01

    In this study, we have evaluated the imaging features of Warthin's tumor of the parotid gland with the use of CT and MR imaging. CT (n = 30) and MR (n = 7) images of 26 patients (M:F=23:3; age range, 38-76 years; mean age, 58 years) with surgically-proven Warthin's tumor (n = 37) were reviewed with a focus on bilaterality, multiplicity, location, size, demarcation, margin, enhancement pattern and MR signal intensity. Lesions were bilateral in seven patients (27%), multiple in nine patients (35%) and unilateral multiple in four patients (15%). Tumors were located in the superficial lobe (65%), deep lobe (24%) and both lobes (11%) of the parotid gland. Most tumors had a clear (95%) and smooth margin (95%) with a round or oval shape. Tumors mainly showed a solid and cystic composition (n = 24, 65%) and all solid stroma showed poor or weak enhancement on both CT and MR images. Papillary projections from the peripheral wall were clearly seen (n = 6, 86%). Warthin's tumor is frequently seen in the parotid superficial lobe of older males with a higher bilateral and multiple tendency. Warthin's tumor shows cystic portions with papillary projections at the wall on CT images and focal high signal intensity (SI) on T1-weighted images with dense nodular enhancement on MR images

  8. Polydopamine-coated gold nanostars for CT imaging and enhanced photothermal therapy of tumors

    Science.gov (United States)

    Li, Du; Shi, Xiangyang; Jin, Dayong

    2016-12-01

    The advancement of biocompatible nanoplatforms with dual functionalities of diagnosis and therapeutics is strongly demanded in biomedicine in recent years. In this work, we report the synthesis and characterization of polydopamine (pD)-coated gold nanostars (Au NSs) for computed tomography (CT) imaging and enhanced photothermal therapy (PTT) of tumors. Au NSs were firstly formed via a seed-mediated growth method and then stabilized with thiolated polyethyleneimine (PEI-SH), followed by deposition of pD on their surface. The formed pD-coated Au NSs (Au-PEI@pD NSs) were well characterized. We show that the Au-PEI@pD NSs are able to convert the absorbed near-infrared laser light into heat, and have strong X-ray attenuation property. Due to the co-existence of Au NSs and the pD, the light to heat conversion efficiency of the NSs can be significantly enhanced. These very interesting properties allow their uses as a powerful theranostic nanoplatform for efficient CT imaging and enhanced phtotothermal therapy of cancer cells in vitro and the xenografted tumor model in vivo. With the easy functionalization nature enabled by the coated pD shell, the developed pD-coated Au NSs may be developed as a versatile nanoplatform for targeted CT imaging and PTT of different types of cancer.

  9. Metastatic liver tumor from cystic ovarian carcinomas. CT and MRI appearance

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi; Yamashita, Yasuyuki; Ogata, Ichiro; Namimoto, Tomohiro; Abe, Yasuko; Urata, Joji; Takahashi, Mutsumasa [Kumamoto Univ. (Japan). School of Medicine

    1999-08-01

    The initial and follow-up CT and MRI images of ten patients with hepatic metastases from ovarian tumors were retrospectively analyzed to establish their features and sequential changes in appearance. Ten patients with hepatic metastasis from ovarian tumors received initial and follow-up CT and MRI examinations. Six patients were followed up every two to three weeks before surgical tumor resection. Both CT and MR images were analyzed by two radiologists. A total of fourteen lesions were detected by CT and MRI in 10 patients. All 14 lesions were demonstrated as areas of marked hyperintensity on T2-weighted MRI. Eleven cyst-like tumors were demonstrated as round or oval low density lesions on CT and as areas of hypointensity on T1-weighted imaging. Three lesions were shown as solid masses with slightly low attenuation at the initial CT examination and slightly low or iso-intensity areas on T1-weighted imaging, and these lesions showed early peripheral globular enhancement and delayed enhancement on contrast-enhanced CT and MR imaging. Cystic formation was observed two to three weeks later after initial study in all the 3 solid lesions. Rapid subcapsular effusion, which showed obvious enhancement on delayed Gd-DTPA enhanced MR imaging, was observed in two patients. The hepatic metastatic tumor from cystic ovarian carcinoma may manifest as a well-defined cystic lesion or as a solid mass, and the solid mass shows delayed enhancement on contrast-enhanced CT and MR imaging. Furthermore, rapid cystic formation and rapid subcapsular extension is frequently seen. (author)

  10. Peritumoral brain edema in intracranial tumor evaluated by CT perfusion imaging

    International Nuclear Information System (INIS)

    Shi Yuxin; Xu Jianfeng

    2005-01-01

    Objective: To semi-quantitatively evaluate the cerebral perfusion in the peritumoral brain edema of cerebral tumors using CT perfusion imaging. Methods: Twenty-one patients with peritumoral brain edema (including pathologically confirmed meningiomas n=4, metastasis n=10, gliomas n=7) were examined by CT perfusion imaging. The regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) were calculated for peritumoral brain edema and the contralateralwhite matter. The rCBF and rCBV were compared between peritumoral brain edema and the contralateral white matter. The mean ratios (edema/contralateral white matter) of rCBF and rCBV were compared among the three tumors. Results: The rCBF and rCBV of peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis (rCBF: t=2.92 and 3.82, P 0.05). The mean ratios (edema/contralateralwhite matter) of rCBF and rCBV were not significantly different between meningiomas and metastasis (t=0.23 and 0.73, P>0.05), but both of them were significantly lower than those of gliomas (t=3.05 and 3.37, P<0.01, 0.005). Conclusion: The rCBF and rCBV in peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis, while almost the same with or higher than those of contralateral white matter in patients with gliomas. CT perfusion can provide quantitative information of blood flow in peritumoral brain edema, and is useful in the diagnosis and follow-up of cerebral tumors. (authors)

  11. The application of PET-CT in gastrointestinal stromal tumor

    International Nuclear Information System (INIS)

    Xian Weijun; Feng Yanlin

    2009-01-01

    Gastrointestinal stromal tumor (GIST) is a mesenchymal neoplasm of uncertain malignant potential that arises predominantly in the gastrointestinal tract. Due to lack of specific physical signs, imagin g-x examination is an important auxiliary means in diagnosing gastrointestinal stromal tumor. Compared to other conventional imaging examinations, PET-CT has demonstrated unique superiority in staging, response evaluation and follow-up of gastrointestinal stromal tumor. And now it presents an overview of the application valuation of PET-CT and related imaging technology in gastrointestinal stromal tumor as follow. (authors)

  12. Edema in the retropharyngeal space associated with head and neck tumors: CT imaging characteristics

    International Nuclear Information System (INIS)

    Kurihara, Noriko; Nakamura, Mamoru; Tsuda, Masashi; Saito, Haruo; Takahashi, Shoki; Higano, Shuichi

    2005-01-01

    To determine computed tomographic (CT) imaging characteristics of retropharygeal edema, we reviewed CT images in 18 patients with head and neck tumors. Retropharyngeal edema spread craniocaudally between soft palate and upper half of thyroid cartilage in all patients. No edema fluid extended above soft palate and below thyroid cartilage. Horizontally, it spread symmetrically in ten and asymmetrically in eight patients. Predominance in asymmetrical retropharyngeal edema was found on the same side as that of unilateral predominance both in lymph nodes enlargement and jugular vein stenosis/occlusion. All patients had edema also in other cervical spaces. Edema of retropharyngeal and other spaces fluctuated synchronously. In 14 patients, as primary lesion and/or cervical lymph nodes regressed, retropharyngeal edema disappeared or decreased. Retropharyngeal edema had some imaging characteristics. With knowledge of that, we could avoid diagnostic confusion when evaluating head and neck CT images. (orig.)

  13. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging

    International Nuclear Information System (INIS)

    Liu Chi; Pierce II, Larry A; Alessio, Adam M; Kinahan, Paul E

    2009-01-01

    Our aim is to investigate the impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging using a population of patient respiratory traces. A total of 1295 respiratory traces acquired during whole body PET/CT imaging were classified into three types according to the qualitative shape of their signal histograms. Each trace was scaled to three diaphragm motion amplitudes (6 mm, 11 mm and 16 mm) to drive a whole body PET/CT computer simulation that was validated with a physical phantom experiment. Three lung lesions and one liver lesion were simulated with diameters of 1 cm and 2 cm. PET data were reconstructed using the OS-EM algorithm with attenuation correction using CT images at the end-expiration phase and respiratory-averaged CT. The errors of the lesion maximum standardized uptake values (SUV max ) and lesion volumes between motion-free and motion-blurred PET/CT images were measured and analyzed. For respiration with 11 mm diaphragm motion and larger quiescent period fraction, respiratory motion can cause a mean lesion SUV max underestimation of 28% and a mean lesion volume overestimation of 130% in PET/CT images with 1 cm lesions. The errors of lesion SUV max and volume are larger for patient traces with larger motion amplitudes. Smaller lesions are more sensitive to respiratory motion than larger lesions for the same motion amplitude. Patient respiratory traces with relatively larger quiescent period fraction yield results less subject to respiratory motion than traces with long-term amplitude variability. Mismatched attenuation correction due to respiratory motion can cause SUV max overestimation for lesions in the lower lung region close to the liver dome. Using respiratory-averaged CT for attenuation correction yields smaller mismatch errors than those using end-expiration CT. Respiratory motion can have a significant impact on static oncological PET/CT imaging where SUV and/or volume measurements are important. The impact

  14. CT and MR imaging features in phosphaturic mesenchymal tumor-mixed connective tissue: A case report.

    Science.gov (United States)

    Shi, Zhenshan; Deng, Yiqiong; Li, Xiumei; Li, Yueming; Cao, Dairong; Coossa, Vikash Sahadeo

    2018-04-01

    Phosphaturic mesenchymal tumor-mixed connective tissue (PMT-MCT) is rare and usually benign and slow-growing. The majority of these tumors is associated with sporadic tumor-induced osteomalacia (TIO) or rickets, affect middle-aged individuals and are located in the extremities. Previous imaging studies often focused on seeking the causative tumors of TIO, not on the radiological features of these tumors, especially magnetic resonance imaging (MRI) features. PMT-MCT remains a largely misdiagnosed, ignored or unknown entity by most radiologists and clinicians. In the present case report, a review of the known literature of PMT-MCT was conducted and the CT and MRI findings from three patient cases were described for diagnosing the small subcutaneous tumor. Typical MRI appearances of PMT-MCT were isointense relative to the muscles on T1-weighted imaging, and markedly hyperintense on T2-weighted imaging containing variably flow voids, with markedly heterogeneous/homogenous enhancement on post contrast T1-weighted fat-suppression imaging. Short time inversion recovery was demonstrated to be the optimal sequence in localizing the tumor.

  15. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  16. DELAYED FDG-PET/CT IMAGES IN PATIENTS WITH BRAIN TUMORS - IMPACT ON VISUAL AND SEMIQUANTITATIVE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Pavel H. Bochev

    2013-01-01

    Full Text Available Background: Despite the extensive use of FDG-PET/CT its role in brain tumor assessment remains controversial mostly because of the physiologically high brain uptake which easily obscures pathological processes. The wide availability of FDG, however, maintains the interest in FDG neuro-oncological applications. Objective: to evaluate the use of a late registration at 180min in patients with brain tumors, studied with FDG-PET/CT based on visual and semiquantitative analysis. Materials and methods: 38 patients with brain neoplasms and non-tumor structural lesions underwent a selective brain 18F-FDG PET/CT at two time points at 60 and 180 minutes after administration. Visual assessment was made by two readers with interobserver agreement calculation. Region ratio comparison with three different reference regions - the contralateral one, the white matter, and the cerebellum was used as a base for semiquantitative analysis. Results: Visual analysis showed better delineation of malignant lesion on late registrations with higher inter/intraobserver agreement as compared to the early images. Semiquantitative analysis demonstrated significant differences in early and late indices of metastases and gliomas, but failed in distinguishing gliomas from metastatic lesions and benign lesions.Conclusion: Delayed brain images with FDG-PET/CT at 180 min after injection provide better tumor delineation, higher accuracy, lower interobserver variations. The use of semiquantitative indices, irrespective of the reference region used, is of limited value

  17. CT and MR imaging characteristics of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Ching, A.S.C.; Sun Canhui; Guo Huanyi; Fan Miao; Meng Quanfei; Li Ziping

    2010-01-01

    Aim: This study aims to analyze computed tomography (CT) and magnetic resonance (MR) imaging features of infantile hepatic hemangioendotheliomas before and after treatment. Materials and methods: CT and MR examinations of seven infants with biopsy proven hepatic hemangioendotheliomas were retrospectively analyzed. The distribution, number, size, imaging appearance, enhancement pattern and post-treatment changes of the tumors were evaluated. Results: A total of 153 hepatic hemangioendotheliomas were detected on CT (111) and MR (42) imaging. In six infants, 109/111 (98.2%) tumors were hypodense and 2/111 (1.8%) lesions contained calcification on unenhanced CT. On MR imaging, all 42 lesions in one infant were heterogeneously T1-hypointense and T2-hyperintense compared to the normal liver parenchyma. Contrast-enhanced CT and MRI showed peripheral rim (51.6%), uniform (48.4%), fibrillary (33.3%), and nodular (28.8%) contrast enhancement in the hepatic arterial phase. Homogeneous (100%), rim (98.2%) and mixed enhancement patterns were noted in tumors 2.0 cm and 1.0-2.0 cm in diameter respectively in the hepatic arterial phase. In three patients who underwent steroid therapy, follow-up CT examination demonstrated tumor size reduction and increased intra-tumoral calcification in two patients. Conclusion: Infantile hepatic hemangioendotheliomas show some typical imaging features and size-dependent pattern of contrast enhancement on CT and MR imaging, which allow accurate imaging diagnosis and post-treatment evaluation.

  18. CT imaging findings of neuroendocrine tumor arising from tailgut cyst: a case report

    International Nuclear Information System (INIS)

    Aydin, N.; Kara, T.; Kebapci, M.

    2012-01-01

    Full text: Introduction: We present a case of neuroendocrine tumor which is arisen from a tailgut cyst in a middle aged woman with its computed tomography (CT) imaging findings. Objective and tasks:The tailgut normally involutes by the eighth week of gestational age. If a tailgut rest proceeds, it may give rise to a tailgut cyst in the presacral space. Malign transformation of the tailgut cyst is very rare. Material and methods: A 35-year-old woman with a history of endometriosis admitted to our hospital for her routine control.An ultrasonography examination and contrast medium enhanced tomography of the abdomen and pelvis were performed. Results: CT showed multiple well-defined solid heterogen masses in presacral space. The patient underwent surgery. Pathology was reported as neuroendocrine tumor arising within tailgut cyst. Conclusion: Adenocarcinoma, neuroendocrine carcinoma, and sarcoma developing within the tailgut cyst has been reported. CT shows well-marginated presacral mass.If concurrent malignant transformation occurs, CT shows loss of margins and involvement of adjacent structures.Diagnosis of tailgut cyst is important because of it's malignant potential

  19. FDG PET/CT imaging of desmoplastic small round cell tumor: findings at staging, during treatment and at follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Ostermeier, Austin; Snyder, Scott E.; Shulkin, Barry L. [St. Jude Children' s Research Hospital, Department of Radiological Sciences, MS 220, Memphis, TN (United States); McCarville, M.B. [St. Jude Children' s Research Hospital, Department of Radiological Sciences, MS 220, Memphis, TN (United States); College of Medicine, University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); Navid, Fariba [St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Pediatrics, College of Medicine, Memphis, TN (United States)

    2015-08-15

    Desmoplastic small round cell tumor (DSRCT) is a very uncommon soft-tissue tumor of children and young adults. It has an aggressive course with generally poor survival. In general the assessment of tumor burden and response has relied upon CT or MRI. However these tumors are often metabolically active and can be evaluated using FDG PET/CT imaging. The purpose of this study was to determine the metabolic activity of desmoplastic small round cell tumors using FDG PET/CT imaging and the potential utility of FDG PET/CT in this disease. Eight patients (seven male, one female; ages 2-20 years, median 11 years) with confirmed DSRCT underwent 82 positron emission tomography/computed tomography (PET/CT) scans. PET/CT was used for initial staging (seven patients, eight scans), monitoring response to therapy (eight patients, 37 scans) and for surveillance of DSRCT recurrence (six patients, 37 scans). Each scan performed at diagnosis showed abnormally elevated uptake in the primary tumor. Five patients had abdominal pelvic involvement, and two of those also had thoracic disease. Six patients whose scans showed no abnormal sites of uptake at the end of therapy have had progression-free survivals of 2-10 years. One patient whose scan continued to show uptake during treatment died of disease 1.3 years from diagnosis. Another patient with persistent uptake remained in treatment 3 years after initial diagnosis. One surveillance scan identified recurrent disease. FDG PET/CT identified elevated metabolic activity in each patient studied. Despite our small sample size, FDG PET/CT scans appear useful for the management of patients with DSCRT. Patients whose studies become negative during or following treatment may have a prolonged remission. (orig.)

  20. Automated segmentation of murine lung tumors in x-ray micro-CT images

    Science.gov (United States)

    Swee, Joshua K. Y.; Sheridan, Clare; de Bruin, Elza; Downward, Julian; Lassailly, Francois; Pizarro, Luis

    2014-03-01

    Recent years have seen micro-CT emerge as a means of providing imaging analysis in pre-clinical study, with in-vivo micro-CT having been shown to be particularly applicable to the examination of murine lung tumors. Despite this, existing studies have involved substantial human intervention during the image analysis process, with the use of fully-automated aids found to be almost non-existent. We present a new approach to automate the segmentation of murine lung tumors designed specifically for in-vivo micro-CT-based pre-clinical lung cancer studies that addresses the specific requirements of such study, as well as the limitations human-centric segmentation approaches experience when applied to such micro-CT data. Our approach consists of three distinct stages, and begins by utilizing edge enhancing and vessel enhancing non-linear anisotropic diffusion filters to extract anatomy masks (lung/vessel structure) in a pre-processing stage. Initial candidate detection is then performed through ROI reduction utilizing obtained masks and a two-step automated segmentation approach that aims to extract all disconnected objects within the ROI, and consists of Otsu thresholding, mathematical morphology and marker-driven watershed. False positive reduction is finally performed on initial candidates through random-forest-driven classification using the shape, intensity, and spatial features of candidates. We provide validation of our approach using data from an associated lung cancer study, showing favorable results both in terms of detection (sensitivity=86%, specificity=89%) and structural recovery (Dice Similarity=0.88) when compared against manual specialist annotation.

  1. Preliminary study of spectral CT imaging in the differential diagnosis of metastatic lymphadenopathy due to various tumors

    International Nuclear Information System (INIS)

    Liu Jingang; Liu Ya; Li Lixin

    2011-01-01

    Objective: To investigate the feasibility of differentiating lymph node metastases of four types of primary tumors (lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma) using gemstone spectral imaging (GSI). Methods: Three cases with lymphoma (28 lymph node), five cases with lung adenocarcinoma (30 lymph node), four cases with lung squamous cell carcinoma (24 lymph node) and two cases with cholangiocarcinoma (10 lymph node) were evaluated by germstona spectra imaging CT scans. Imaging protocol included unenhanced conventional CT scan (120 kVp), enhanced GSI (80/140 kVp) on arterial phase and conventional CT scan (120 kVp) on portal phase. CT attenuation values of lymph nodes in the monochromatic images at Il sets of keV levels (40- 140 keV, 10 keV step) and the iodine and water contents of these lymph nodes were measured. All results were analyzed with ANOVA and t test. Results: The optimal monochromatic level was 70 keV for the optimal contrast-noise ratio (CNR) of metastatic lymphadenopathy. The CT attenuation values of metastatic lymphadenopathy were (81.36±9.81), (58.33±21.55), (56.47±10.62) and (73.57±4.43) HU, respectively, at 70 keV (F=17.29, P 0.05). The iodine contents of lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma were (1.93±0.04), (1.16±0.15), (1.25±0.21) and (1.44±0.04) g/L, respectively. The water contents of lymphoma, lung adenocarcinoma, lung squamous cell carcinoma and cholangiocarcinoma were (1029.40±20.85), (1024.98±11.19), (1022.12±12.94) and (1030.87±10.10) g/L, respectively. Except between lung squamous cell carcinoma and lung adenocarcinoma, the differences in the iodine contents of metastatic lymphadenopathy were significant among tumors (P 0.05 ). Conclusions: Although CT spectral imaging fails to differentiate metastatic lymphadenopathy of lung adenocarcinoma and lung squamous cell carcinoma, it is also a promising method of distinguishing metastatic

  2. Craniopharyngioma identification by CT and MR imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Eldevik, O.P. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Skalpe, I.O. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States)

    1995-03-01

    To compare the detectability of craniopharyngiomas by CT and MR imaging, preoperative CT and MR studies obtained within 16 days of each other were evaluated retrospectively in 9 patients. MR imaging demonstrated cystic and solid tumor components in all 9 tumors, and enhancement in the 7 tumors that were studied after contrast medium injection. MR imaging demonstrated a signal void consistent with calcification in 4 patients. Combining unenhanced and contrast medium-enhanced studies, CT also identified all the tumors. CT demonstrated cysts in 7 lesions, calcification in 7 and enhancement in 6 of the 7 lesions that received i.v. contrast medium. Calcification was better seen by CT than MR imaging, while MR imaging identified cystic tumor components not seen on CT. The contrast medium enhancement pattern was the same with the 2 modalities. MR imaging of the sellar region, including at least one contrast medium-enhanced sequence, should be sufficient in most instances to establish a preoperative diagnosis of craniopharyngioma. (orig.).

  3. Salivary gland tumors of the parotid gland: CT and MR imaging findings with emphasis on intratumoral cystic components

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki; Watanabe, Haruo [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Kanematsu, Masayuki [Gifu University School of Medicine, Department of Radiology, Gifu (Japan); Gifu University Hospital, High-Level Imaging Diagnosis Center, Gifu (Japan); Mizuta, Keisuke; Aoki, Mitsuhiro [Gifu University School of Medicine, Department of Otolaryngology, Gifu (Japan)

    2014-09-15

    The purpose of this study was to assess computed tomography (CT) and magnetic resonance (MR) imaging findings of salivary gland tumors of the parotid gland with emphasis on intratumoral cystic components. Seventy-two histopathologically confirmed salivary gland tumors of the parotid gland (44 benign and 28 malignant), which underwent both CT and MR imaging including contrast-enhanced study, were included in this study. We retrospectively reviewed images for the presence, number, occupying rate, margin characteristics, distribution, and predominant MR signal intensity of intratumoral cystic components. The prevalence of cystic components was greater in malignant than benign tumors (79 vs. 50 %, p < 0.05). The number and occupying rate were similar between benign and malignant tumors. The irregular margins were more frequent in malignant than benign tumors (73 vs. 27 %, p < 0.01). The frequency of eccentric location was greater in benign than malignant tumors (91 vs. 55 %, p < 0.01), whereas the frequency of centric location was greater in malignant than benign tumors (32 vs. 0 %, p < 0.01). On T1-weighted images, the frequency of hyperintensity was greater in benign than malignant tumors (50 vs. 9 %, p < 0.01), whereas that of isointensity was greater in malignant than benign tumors (50 vs. 0 %, p < 0.01). Multiple logistic regression analysis showed that the absence of irregular margins of cystic components only was significantly correlated with the presence of benign salivary gland tumors (p < 0.01). Imaging features of intratumoral cystic components may help to differentiate benign from malignant tumors of the parotid salivary gland. (orig.)

  4. New radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagishita, A.; Shiga, I.; Kanzaki, H. (Keio Univ., Tokyo (Japan). School of Medicine)

    1982-07-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors.

  5. New radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagishita, A; Shiga, I; Kanzaki, H [Keio Univ., Tokyo (Japan). School of Medicine

    1982-07-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors.

  6. CT and MR imaging of gastrointestinal stromal tumor of stomach: a pictorial review

    OpenAIRE

    Gong, Jingshan; Kang, Wenyan; Zhu, Jin; Xu, Jianmin

    2012-01-01

    This pictorial review illustrates CT and MR imaging appearance of gastrointestinal stromal tumor (GIST) of the stomach and other lesions with similar imaging appearance. GIST of the stomach appears as well-defined enhanced masses with characteristics of subeppthial neoplasms. Majority are exophytic growth, but can also be of intra-luminal growth. GIST can growth into a large mass without gastrointestinal tract obstruction. Necrosis is often seen in GIST and results in heterogeneous enhancemen...

  7. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    Science.gov (United States)

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  8. An integrated 3-D image of cerebral blood vessels and CT view of tumor

    International Nuclear Information System (INIS)

    Suetens, P.; Baert, A.L.; Gybels, J.; Haegemans, S.; Jansen, P.; Oosterlinck, A.; Wilms, G.

    1984-01-01

    The authors developed a method that yields an integrated three-dimensional image of cerebral blood vessels and CT view of tumor. This method allows the neurosurgeon to choose any electrode trajectory that looks convenient to him, without imminent danger of causing a hemorrhage. Besides offering more safety to stereotactic interventions, this integrated 3-D image also has other applications. First, it gives a better characterization of most focal mass lesions seen by CT. Second, it allows high dose focal irradiation to be effected in such a way as to avoid arteries and veins. Third, it provides useful information for planning the strategy of open surgery

  9. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  10. CT and MR imaging in atypical teratoid/rhabdoid tumors of the central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Warmuth-Metz, Monika [University of Wuerzburg, Reference Centre for Neuroradiology of the German Society for Pediatric Hematology and Oncology (GPOH), Department of Neuroradiology, Wuerzburg (Germany); Abteilung fuer Neuroradiologie der Universitaet Wuerzburg, Wuerzburg (Germany); Bison, Brigitte [University of Wuerzburg, Reference Centre for Neuroradiology of the German Society for Pediatric Hematology and Oncology (GPOH), Department of Neuroradiology, Wuerzburg (Germany); Dannemann-Stern, Elke; Kortmann, Rolf [University of Tuebingen, Reference Centre for Radiooncology of the German Society for Pediatric Hematology and Oncology (GPOH), Department of Radiooncology, Tuebingen (Germany); Rutkowski, Stefan [University of Wuerzburg, Study Centre of the HIT-Studies of the German Society for Pediatric Hematology and Oncology (GPOH), Department of Pediatrics, Wuerzburg (Germany); Pietsch, Torsten [University of Bonn, German Reference Centre for Neuropathology, Bonn (Germany)

    2008-05-15

    Atypical teratoid/rhabdoid tumors (ATRT) are rare aggressive neoplasms of the CNS affecting predominantly very young children. We retrospectively reviewed the imaging findings of 9 CT and 32 MR examinations of the brain and spine of 33 children. Of the 33 tumors, 11 were located in the infratentorial compartment, 16 in the supratentorial compartment, 5 in both cranial compartments, and 1 in the lower thoracic spinal cord. The mean age of the children with infratentorial or infra- and supratentorial tumors was significantly lower than the mean age of the children with purely supratentorial tumors. Heterogeneity on imaging, large size and high tumor stages are striking features reflecting the aggressive nature of this histopathological entity. Although not present in the majority of children, a distinct and unusual pattern of a wavy band-like enhancement surrounding a central hypointensity was present in 12 of 32 children (38%) in whom contrast medium was used. To the best of our knowledge this is the largest number of imaging examinations of ATRTs so far reported. A rather unusual pattern of contrast enhancement may be typical of ATRTs. (orig.)

  11. Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Ramsey, Chester; Meeks, Sanford L.; Willoughby, Twyla R.; Forbes, Alan; Wagner, Thomas H.; Langen, Katja M.

    2005-01-01

    Purpose: The ability to obtain soft-tissue imaging in the treatment room, such as with megavoltage CT imaging, enables the observation of tumor regression during a course of external beam radiation therapy. In this current study, we report on the most extensive study looking at the rate of regression of non-small-cell lung cancers during a course of external beam radiotherapy by analyzing serial megavoltage CT images obtained on 10 patients. Methods and Materials: The analysis is performed on 10 patients treated with the Helical Tomotherapy Hi*Art device. All 10 patients had non-small-cell lung cancer. A total of 274 megavoltage CT sets were obtained on the 10 patients (average, 27 scans per patient; range, 9-35). All patients had at least a scan at beginning and at the end of treatment. The frequency of scanning was determined by the treating physician. The treatment was subsequently delivered with the Tomotherapy Hi*Art system. The gross tumor volumes (GTVs) were later contoured on each megavoltage CT scan, and tumor volumes were calculated. Although some patients were treated to draining nodal areas in addition to the primary tumor, only the primary GTVs were tracked. Response to treatment was quantified by the relative decrease in tumor volume over time, i.e., elapsed days from the first day of therapy. The individual GTVs ranged from 5.9 to 737.2 cc in volume at the start of treatment. In 6 of the 10 patients, dose recalculations were also performed to document potential variations in delivered doses within the tumors. The megavoltage CT scans were used, and the planned treatment was recalculated on the daily images. The hypothesis was that dose deposited in the target would increase throughout the course of radiotherapy because of tumor shrinkage and subsequent decreasing attenuation. Specifically, the dose received by 95% of the GTV (D 95 ) was monitored over time for each of the 6 patients treated at M.D. Anderson Cancer Center Orlando. Results: Regression

  12. Molecular imaging of neuroendocrine tumors using {sup 68}Ga-labeled peptides (Somatostatin receptor PET/CT); Molekulare Bildgebung neuroendokriner Tumoren mit {sup 68}Ga-markierten Peptiden (Somatostatinrezeptor-PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R.P.; Prasad, V. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Hoersch, D. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Innere Medizin, Gastroenterologie, Onkologie, Endokrionologie

    2009-06-15

    Receptor PET/CT using {sup 68}Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The {sup 68}Ge/{sup 68}Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for {sup 68}Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the {sup 68}Ga generator could play a similar important role for PET/CT as did the {sup 99m}Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  13. CT and MRI of germ-cell tumors with metastasis or multi-located tumors

    International Nuclear Information System (INIS)

    Miyagami, Mitsusuke; Tazoe, Makoto; Tsubokawa, Takashi

    1989-01-01

    Twenty-seven cases of germ-cell tumors were examined with a CT scan in our clinic. In the 11 cases of metastasis or multi-localized tumors, the CT findings were studied in connection with the MRI findings. There were 6 cases of germ-cell tumors which had broad infiltrating tumors with multiple lesions on first admission. Their tumor sites were different from that in cases of malignant glioma, being frequently localized in the pineal and/or the suprasellar region, on the wall of the third and/or lateral ventricle, and in the region of the basal ganglia. Five of the cases of germ-cell tumors had metastasis with various patterns connected to a remote area - that is, to spinal cords, to the ventricular wall and basal cistern of the brain stem by CSF dissemination, to a lung by hematogeneous metastasis, and to the peritoneal wall or organs by a V-P shunt. The CT findings of germ-cell tumors were correlated mainly with the results of the histological diagnosis; they were found not to differ with the tumor site. The germinoma in the suprasellar region had less calcification than in the pineal region. Cysts, calcification, and an enlargement of the lateral ventricle on the tumor side were frequently seen in the germinoma of the basal ganglia. On the MRI of 5 cases of germinoma, the T 1 -weighted image revealed a slightly low or iso signal intensity, while the T 2 -weighted image showed a high signal intensity. In the case of multiple tumor lesions, some cases demonstrated different CT findings and radiosensitivities for each tumor. The possibility of a multicentric origin for the tumors is thus suggested in some cases of germ-cell tumors. (author)

  14. Evaluation of thymic tumors with 18F-FDG PET-CT - A pictorial review

    International Nuclear Information System (INIS)

    Sharma, Punit; Singhal, Abhinav; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh; Kumar, Arvind

    2013-01-01

    Thymic tumors represent a broad spectrum of neoplastic disorders and pose considerable diagnostic difficulties. A non-invasive imaging study to determine the nature of thymic lesions can have significant impact on management of such tumors. 18F-flurorodeoxyglucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) has shown promising results in characterization of thymic tumors. The objective of this article is to provide an illustrative tutorial highlighting the clinical utility of 18F-FDG PET-CT imaging in patients with thymic tumors. We have pictorially depicted the 18F-FDG PET-CT salient imaging characteristics of various thymic tumors, both epithelial and non-epithelial. Also discussed is the dynamic physiology of thymus gland which is to be kept in mind when evaluating thymic pathology on 18F-FDG PET-CT, as it can lead to interpretative pitfalls

  15. The role of CT in the diagnosis of tumors in sellar area

    International Nuclear Information System (INIS)

    Li Wenxin

    2005-01-01

    Objective: To evaluate computed tomography (CT) in patients with tumors in sellar area. Methods: CT images of 33 patients with sellar area tumor's proved by surgery and pathology were analyzed retrospectively. Results: Pituitary adenomas (n=20), craniopharyngiomas (n=8) and meningiomas (n=3) had characteristic findings and were given a high rate of correct diagnosis. While astrocytoma (n=1) and germinoma (n=1) were solid lesions in sellar area and lack of diagnostic signs and the astrocytoma was misdiagnosed as craniopharyngioma. Conclusion: CT, especially 2-demision reconstructed (coronal and sagittal) images can demonstrate inner structure, pattern of growth, extension of invasion of tumors as well as the relationship between tumor and the adjacent vessels. CT plays an important role in the diagnosis of tumors in seliar area. (authors)

  16. A new radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    International Nuclear Information System (INIS)

    Yagishita, Akira; Shiga, Itsuo; Kanzaki, Hitoshi

    1982-01-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors. (author)

  17. CT and MR imaging findings of palatal tumors

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Makita, Hiroki; Kato, Keizo; Hatakeyama, Daijiro; Shibata, Toshiyuki; Mizuta, Keisuke; Aoki, Mitsuhiro

    2014-01-01

    Palatal tumors commonly arise from the minor salivary glands, and benign tumors account for approximately half of all minor salivary gland tumors. Minor salivary gland tumors have an affinity for the posterior hard palate and soft palate and virtually never arise in the midline, probably because of the distribution of palatal salivary glands. The majority of benign salivary gland tumors of the palate are pleomorphic adenomas, while the most common malignant salivary gland tumor is adenoid cystic carcinoma, followed by mucoepidermoid carcinoma, adenocarcinoma, and polymorphous low-grade adenocarcinoma. Epithelial tumors frequently arise from the soft palate. The majority of benign epithelial tumors of the palate are papillomas, while most malignant epithelial tumors are squamous cell carcinomas. Various types of mesenchymal tumors, including fibromas, lipomas, schwannomas, neurofibromas, hemangiomas, and lymphangiomas, also involve the palate. This article describes the CT and MR findings of benign and malignant palatal tumors

  18. CT and MR imaging findings of palatal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki, E-mail: hkato@gifu-u.ac.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Kanematsu, Masayuki, E-mail: masa_gif@yahoo.co.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); High-level Imaging Diagnosis Center, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Makita, Hiroki, E-mail: makitah@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Kato, Keizo, E-mail: keizo@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Hatakeyama, Daijiro, E-mail: hatakeya@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Shibata, Toshiyuki, E-mail: shibat@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Mizuta, Keisuke, E-mail: kmizuta@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan); Aoki, Mitsuhiro, E-mail: aoki@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan)

    2014-03-15

    Palatal tumors commonly arise from the minor salivary glands, and benign tumors account for approximately half of all minor salivary gland tumors. Minor salivary gland tumors have an affinity for the posterior hard palate and soft palate and virtually never arise in the midline, probably because of the distribution of palatal salivary glands. The majority of benign salivary gland tumors of the palate are pleomorphic adenomas, while the most common malignant salivary gland tumor is adenoid cystic carcinoma, followed by mucoepidermoid carcinoma, adenocarcinoma, and polymorphous low-grade adenocarcinoma. Epithelial tumors frequently arise from the soft palate. The majority of benign epithelial tumors of the palate are papillomas, while most malignant epithelial tumors are squamous cell carcinomas. Various types of mesenchymal tumors, including fibromas, lipomas, schwannomas, neurofibromas, hemangiomas, and lymphangiomas, also involve the palate. This article describes the CT and MR findings of benign and malignant palatal tumors.

  19. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  20. Single-level dynamic spiral CT of hepatocellular carcinoma: correlation between imaging features and tumor angiogenesis

    International Nuclear Information System (INIS)

    Chen Weixia; Min Pengqiu; Song Bin; Xiao Bangliang; Liu Yan; Wang Wendong; Chen Xian; Xu Jianying

    2001-01-01

    Objective: To investigate the correlation of the enhancement imaging features of hepatocellular carcinoma (HCC) and relevant parameters revealed by single-level dynamic spiral CT scanning with tumor microvessel counting (MVC). Methods: The study included 26 histopathologically proven HCC patients. Target-slice dynamic scanning and portal venous phase scanning were performed for all patients. The time-density curves were generated with measurement of relevant parameters including: peak value (PV) and contrast enhancement ratio (CER), and the gross enhancement morphology analyzed. Histopathological slides were carefully prepared for the standard F8RA and VEGF immunohistochemical staining and tumor microvessel counting and calculation of VEGF expression percentage of tumor cells. The enhancement imaging features of HCC lesions were correlatively studied with tumor MVC and VEGF expression. Results: Peak value of HCC lesions were 7.9 to 75.2 HU, CER were 3.8% to 36.0%. MVC were 6 to 91, and the VEGF expression percentage were 32.1% to 78.3%. The PV and CER were significantly correlated with tumor tissue MVC (r = 0.508 and 0.423, P < 0.01 and 0.05 respectively). There were no correlations between PV and CER and VEGF expression percentage. Both the patterns of time-density curve and the gross enhancement morphology of HCC lesions were also correlated with tumor MVC, and reflected the distribution characteristics of tumor microvessels within HCC lesions. A close association was found between the likelihood of intrahepatic metastasis of HCC lesions with densely enhanced pseudo capsules and the presence of rich tumor microvessels within these pseudo capsules. Conclusion: The parameters and the enhancement imaging features of HCC lesions on target-slice dynamic scanning are correlated with tumor MVC, and can reflect the distribution characteristics of tumor microvessels within HCC lesions. Dynamic spiral CT scanning is a valuable means to assess the angiogenic activity and

  1. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  2. Evaluation of magnetic resonance imaging in thoracic inlet tumors

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Eiro (Kobe Univ. (Japan). School of Medicine)

    1993-06-01

    To evaluate the detectability of tumor invasion to the thoracic inlet, MRI was performed in 57 patients with thoracic inlet tumor, and the diagnostic accuracy of MRI was compared with that of CT concerning the utility for thoracic inlet lesions. And we assessed abnormal findings in comparison with surgical or autopsy findings. In the local extent of the tumor, the accuracy for tumor invasion to the vessels such as subclavian artery and vein was 94.9% for MRI, and 83.5% for CT, and to the brachial plexus was 95.0% for MRI, and 60.0% for CT. MRI was superior to CT, but MRI was equivalent to CT with regard to invasion to the base of the neck, lateral chest wall, ribs, and vertebral bodies. However on MRI, it is easier to understand the longitudinal tumor extent than on CT. CT has superior spatial resolusion but CT has also disadvantages, such as streak artifact caused by shoulder joints, resulting in image degradation. In contrast, MRI has inherent advantages, and multiple images which facilitate the relationship between tumor and normal structures. Coronal and sagittal MR images facilitated three-dimensional observation of tumor of invasion in the thoracic inlet. Furthermore to improve image quality of MRI for the thoracic inlet, we newly devised a high molecular polyester shell for fixing a surface coil. On the high resolution MR (HR-MR) imaging using our shell, normal lymph nodes, muscles, blood vessels and the branches of the branchial plexus were clearly visualized in detail. Our shell was simple to process and facilitated immobilization of a surface coil. HR-MR technique produces images of high resolution after simple preparation. In conclusion, MRI was very useful for detecting lesions of the thoracic inlet and in deciding surgical indication and the planning for radiotherapy. (author).

  3. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B; He, W; Cvetkovic, D; Chen, L; Fan, J; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

  4. Imaging manifestation of hepatocellular carcinoma with bile duct tumor thrombi

    International Nuclear Information System (INIS)

    Liu Qingyu; Chen Jianyu; Liang Biling; Hu Tao

    2008-01-01

    Objective: To analyze the imaging features of hepatocellular carcinoma(HCC) with bile duct tumor thrombi. Methods: Thirteen patients with bile duct tumor thrombi proved pathologically underwent imaging examination. MR and CT were performed in 3 cases, and 2 cases had CT only and 8 cases had MRI only. Ultrasonography(US) was performed in all 13 patients. The accuracy of bile duct tumor thrombi detection was compared between US, CT and MRI with Fisher test. Results: Liver tumors and bile duct tumor thrombi were demonstrated in all patients on CT or MRI. Presence of intraluminal soft tissue mass was found in four of five cases on CT, and mild enhancement of the intraluminal mass in the arterial phase was noted, dilated bile duct distal to tumor thrombi was detected in all five patients. Eleven Tumor thrombi showed slight low signal intensity on T 1 WI, slight high signal intensity on T 2 WI, and mild to moderate contrast enhancement on the contrast-enhanced MR images. The MRCP findings of tumor thrombi were as follows: interruption, stricture of the bile ducts or irregular filling defect in the bile ducts with dilated intrahepatic ducts, bile duet was abruptly interrupted or showed a 'rat-tail' stricture (n=5); the common bile duct was filled with tumor thrombi, intrahepatic bile duct dilatation and missing common bile duct was noted on MRCP (n=2). Bile duct tumor thrombi were correctly diagnosed in 7 cases on US, and 12 cases on CT or MRI. Six cases were misdiagnosed or miss-diagnosed on US, and 4 cases were misdiagnosed on CT or MRI. There was no significant difference between US and CT/MRI in diagnosis of bile duct tumor thrombi (P=0.270). Conclusion: CT or MR imaging is useful for the diagnosis of HCC with biliary tumor thrombi and for evaluating the extension of thrombi. (authors)

  5. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  6. Study on the application of PET-CT in gynecology tumors

    International Nuclear Information System (INIS)

    Wen Lilian

    2012-01-01

    Gynecology tumors seriously threatened the health of female. With the development of imageology, PET, a functionality examination method, has been widely used in the early diagnosis and monitoring of curative effect in gynecology tumors. PET-CT has the good future in its development because it combined with the advantage of functional and structural imaging. The characters and application of PET-CT in gynecology tumors were reviewed in this paper. (author)

  7. Role of respiratory-gated PET/CT for pancreatic tumors: A preliminary result

    International Nuclear Information System (INIS)

    Kasuya, Takeo; Tateishi, Ukihide; Suzuki, Kazufumi; Daisaki, Hiromitsu; Nishiyama, Yuji; Hata, Masaharu; Inoue, Tomio

    2013-01-01

    Purpose: The aim of this study is to ascertain role of respiratory-gated PET/CT for accurate diagnosis of pancreatic tumors. Materials and methods: Prior to clinical study, the phantom study was performed to evaluate the impact of respiratory motion on lesion quantification. Twenty-two patients (mean age 65 years) with pancreatic tumors were enrolled. Pathological diagnoses by surgical specimens consisted of pancreatic cancer (n = 15) and benign intraductal papillary mucinous neoplasm (IPMN, n = 7). Whole-body scan of non-respiratory-gated PET/CT was performed at first, and subsequent respiratory-gated PET/CT for one bed position was performed. All PET/CT studies were performed prior to surgery. The SUV max obtained by non-respiratory-gated PET/CT and respiratory-gated PET/CT, and percent difference in SUVmax (%SUVmax) were compared. Results: The profile curve of 5 respiratory bin image was most similar to that of static image. The third bin of 5 respiratory bin image showed highest FWHM (24.0 mm) and FWTM (32.7 mm). The mean SUVmax of pancreatic cancer was similar to that of benign IPMN on non-respiratory-gated PET/CT (p = 0.05), whereas significant difference was found between two groups on respiratory-gated PET/CT (p = 0.016). The mean %SUV of pancreatic cancer was greater than that of benign IPMN (p < 0.0001). Identification of the primary tumor in pancreatic head (n = 13, 59%) was improved by using respiratory-gated PET/CT because of minimal affection of physiological accumulation in duodenum. Conclusion: Respiratory-gated PET/CT is a feasible technique for evaluation of pancreatic tumors and allows more accurate identification of pancreatic tumors compared with non-respiratory-gated PET/CT

  8. Imaging findings of sacral tumors

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Hong, Sung Hwan; Choi, Ja Young; Koh, Sung Hye; Chung, Hye Won; Choi, Jung Ah; Kang, Heung Sik

    2003-01-01

    The various pathologic conditions detected at CT and MRI and subsumed by the term 'sacral tumor' include primary bone tumors, sacral canal tumors and metastases. Among these, metastases are much more common than primary bone tumors, of which chordoma is the most common. Although the imaging findings of sacral tumors are nonspecific, a patient's age and sex, and specific findings such as calcification or fluid-fluid levels, can help radiologists in their differential diagnosis. We describe the imaging findings of primary sacral tumors, emphasizing the MRI findings

  9. TH-EF-207A-06: High-Resolution Optical-CT/ECT Imaging of Unstained Mice Femur, Brain, Spleen, and Tumor

    International Nuclear Information System (INIS)

    Yoon, S; Dewhirst, M; Oldham, M; Boss, M; Birer, S

    2016-01-01

    Purpose: Optical transmission and emission computed tomography (optical-CT/ECT) provides high-resolution 3D attenuation and emission maps in unsectioned large (∼1cm 3 ) ex vivo tissue samples at a resolution of 12.9µm 3 per voxel. Here we apply optical-CT/ECT to investigate high-resolution structure and auto-fluorescence in a range of optically cleared mice organs, including, for the first time, mouse bone (femur), opening the potential for study of bone metastasis and bone-mediated immune response. Methods: Three BALBc mice containing 4T1 flank tumors were sacrificed to obtain spleen, brain, tumor, and femur. Tissues were washed in 4% PFA, fixed in EtOH solution (for 5, 10, 10, and 2 days respectively), and then optically cleared for 3 days in BABBs. The femur was also placed in 0.25M aqueous EDTA for 15–30 days to remove calcium. Optical-CT/ECT attenuation and emission maps at 633nm (the latter using 530nm excitation light) were obtained for all samples. Bi-telecentric optical-CT was compared side-by-side with conventional optical projection tomography (OPT) imaging to evaluate imaging capability of these two rival techniques. Results: Auto-fluorescence mapping of femurs reveals vasculatures and fluorescence heterogeneity. High signals (A.U.=10) are reported in the medullary cavity but not in the cortical bone (A.U.=1). The brain strongly and uniform auto-fluoresces (A.U.=5). Thick, optically dense organs such as the spleen and the tumor (0.12, 0.46OD/mm) are reconstructed at depth without significant loss of resolution, which we attribute to the bi-telecentric optics of optical-CT. The attenuation map of tumor reveals vasculature, attenuation heterogeneity, and possibly necrotic tissue. Conclusion: We demonstrate the feasibility of optical-CT/ECT imaging of un-sectioned mice bones (femurs) and spleen with high resolution. This result, and the characterization of unstained organs, are important steps enabling future studies involving optical-CT/ECT applied

  10. Primary staging of laryngeal and hypopharyngeal cancer: CT, MR imaging and dual-energy CT

    International Nuclear Information System (INIS)

    Kuno, Hirofumi; Onaya, Hiroaki; Fujii, Satoshi; Ojiri, Hiroya; Otani, Katharina; Satake, Mitsuo

    2014-01-01

    Laryngeal and hypopharyngeal cancer, in particular T4a disease associated with cartilage invasion and extralaryngeal spread, needs to be evaluated accurately because treatment can impact heavily on a patient's quality of life. Reliable imaging tools are therefore indispensible. CT offers high spatial and temporal resolution and remains the preferred imaging modality. Although cartilage invasion can be diagnosed with acceptable accuracy by applying defined criteria for combinations of erosion, lysis and transmural extralaryngeal spread, iodine-enhanced tumors and non-ossified cartilage are sometimes difficult to distinguish. MR offers high contrast resolution for images without motion artifacts, although inflammatory changes in cartilage sometimes resemble cartilage invasion. With dual-energy CT, combined iodine overlay images and weighted average images can be used for evaluation of cartilage invasion, since iodine enhancement is evident in tumor tissue but not in cartilage. Extralaryngeal spread can be evaluated from CT, MR or dual-energy CT images and the routes of tumor spread into the extralaryngeal soft tissue must be considered; (1) via the thyrohyoid membrane along the superior laryngeal neurovascular bundle, (2) via the inferior pharyngeal constrictor muscle, and (3) via the cricothyroid membrane. Radiologists need to understand the advantages and limitations of each imaging modality for staging of laryngeal and hypopharyngeal cancer

  11. The importance of PET/CT in the evaluation of patients with Ewing tumors

    Directory of Open Access Journals (Sweden)

    Júlio Brandão Guimarães

    2015-06-01

    Full Text Available Abstract The effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging.

  12. CT of abdominal tumor

    International Nuclear Information System (INIS)

    Endo, Satoshi; Yamada, Kenji; Ito, Masatoshi; Ito, Hisao; Yamaura, Harutsugu

    1981-01-01

    CT findings in 33 patients who had an abdominal tumor were evaluated. CT revealed a tumor in 31 cases. The organ from which the tumor originated was correctly diagnosed in 18 patients. Whether the tumor was solid or cystic was correctly predicted in 28 patients. The diagnosis malignant or benign nature of tumor was correct, incorrect and impossible, in 23, 3, and five patiens, respectively. (Kondo, M.)

  13. Development of virtual CT DICOM images of patients with tumors: application for TPS and Monte Carlo dose evaluation

    International Nuclear Information System (INIS)

    Milian, F. M.; Attili, A.; Russo, G; Marchetto, F.; Cirio, R.; Bourhaleb, F.

    2013-01-01

    A novel procedure for the generation of a realistic virtual Computed Tomography (CT) image of a patient, using the advanced Boundary RE Presentation (BREP)-based model MASH, has been implemented. This method can be used in radiotherapy assessment. It is shown that it is possible to introduce an artificial cancer, which can be modeled using mesh surfaces. The use of virtual CT images based on BREP models presents several advantages with respect to CT images of actual patients, such as automation, control and flexibility. As an example, two artificial cases, namely a brain and a prostate cancer, were created through the generation of images and tumor/organ contours. As a secondary objective, the described methodology has been used to generate input files for treatment planning system (TPS) and Monte Carlo code dose evaluation. In this paper, we consider treatment plans generated assuming a dose delivery via an active proton beam scanning performed with the INFN-IBA TPS kernel. Additionally, Monte Carlo simulations of the two treatment plans were carried out with GATE/GEANT4. The work demonstrates the feasibility of the approach based on the BREP modeling to produce virtual CT images. In conclusion, this study highlights the benefits in using digital phantom model capable of representing different anatomical structures and varying tumors across different patients. These models could be useful for assessing radiotherapy treatment planning systems (TPS) and computer simulations for the evaluation of the adsorbed dose. (author)

  14. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small......Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...

  15. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  16. TU-AB-202-07: A Novel Method for Registration of Mid-Treatment PET/CT Images Under Conditions of Tumor Regression for Patients with Locally Advanced Lung Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Sharifi, Hoda [Department of Radiation Oncology, Henry Ford Health System, Detroit, MI (United States); Department of Physics, Oakland University, Rochester, MI (United States); Zhang, Hong; Jin, Jian-Yyue; Kong, Feng-Ming [Department of Radiation Oncology, GRU Cancer Center, Augusta GA (United States); Chetty, Indrin J [Department of Radiation Oncology, Henry Ford Health System, Detroit, MI (United States); Zhong, Hualiang

    2016-06-15

    Purpose: In PET-guided adaptive radiotherapy (RT), changes in the metabolic activity at individual voxels cannot be derived until the duringtreatment CT images are appropriately registered to pre-treatment CT images. However, deformable image registration (DIR) usually does not preserve tumor volume. This may induce errors when comparing to the target. The aim of this study was to develop a DIR-integrated mechanical modeling technique to track radiation-induced metabolic changes on PET images. Methods: Three patients with non-small cell lung cancer (NSCLC) were treated with adaptive radiotherapy under RTOG 1106. Two PET/CT image sets were acquired 2 weeks before RT and 18 fractions after the start of treatment. DIR was performed to register the during-RT CT to the pre-RT CT using a B-spline algorithm and the resultant displacements in the region of tumor were remodeled using a hybrid finite element method (FEM). Gross tumor volume (GTV) was delineated on the during-RT PET/CT image sets and deformed using the 3D deformation vector fields generated by the CT-based registrations. Metabolic tumor volume (MTV) was calculated using the pre- and during–RT image set. The quality of the PET mapping was evaluated based on the constancy of the mapped MTV and landmark comparison. Results: The B-spline-based registrations changed MTVs by 7.3%, 4.6% and −5.9% for the 3 patients and the correspondent changes for the hybrid FEM method −2.9%, 1% and 6.3%, respectively. Landmark comparisons were used to evaluate the Rigid, B-Spline, and hybrid FEM registrations with the mean errors of 10.1 ± 1.6 mm, 4.4 ± 0.4 mm, and 3.6 ± 0.4 mm for three patients. The hybrid FEM method outperforms the B-Spline-only registration for patients with tumor regression Conclusion: The hybrid FEM modeling technique improves the B-Spline registrations in tumor regions. This technique may help compare metabolic activities between two PET/CT images with regressing tumors. The author gratefully

  17. Brain tumor and CT, 1. Relationship between the consistency of a brain tumor and the CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, N.; Katada, K.; Shinomiya, Y.; Sano, H.; Kanno, T. (Fujita Gakuen Univ., School of Medicine, Toyoake, Aichi (Japan))

    1981-08-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively. Twenty-seven cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor.

  18. Improvement of internal tumor volumes of non-small cell lung cancer patients for radiation treatment planning using interpolated average CT in PET/CT.

    Directory of Open Access Journals (Sweden)

    Yao-Ching Wang

    Full Text Available Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT or positron emission tomography (PET images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpolated average CT (IACT as attenuation correction (AC to diminish the occurrence of this scenario. Thirteen non-small cell lung cancer patients were recruited for the present comparison study. Each patient had full-inspiration, full-expiration CT images and free breathing PET images by an integrated PET/CT scan. IACT for AC in PET(IACT was used to reduce the PET/CT misalignment. The standardized uptake value (SUV correction with a low radiation dose was applied, and its tumor volume delineation was compared to those from HCT/PET(HCT. The misalignment between the PET(IACT and IACT was reduced when compared to the difference between PET(HCT and HCT. The range of tumor motion was from 4 to 17 mm in the patient cohort. For HCT and PET(HCT, correction was from 72% to 91%, while for IACT and PET(IACT, correction was from 73% to 93% (*p<0.0001. The maximum and minimum differences in SUVmax were 0.18% and 27.27% for PET(HCT and PET(IACT, respectively. The largest percentage differences in the tumor volumes between HCT/PET and IACT/PET were observed in tumors located in the lowest lobe of the lung. Internal tumor volume defined by functional information using IACT/PET(IACT fusion images for lung cancer would reduce the inaccuracy of tumor delineation in radiation therapy planning.

  19. Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT

    Science.gov (United States)

    Krol, Andrzej; Naveed, Muhammad; McGrath, Mary; Lisi, Michele; Lavalley, Cathy; Feiglin, David

    2015-03-01

    The aim of this study was to evaluate if effective radiation dose due to PET component in adult whole-body tumor imaging with time-of-flight F-18 FDG PET/CT could be significantly reduced. We retrospectively analyzed data for 10 patients with the body mass index ranging from 25 to 50. We simulated F-18 FDG dose reduction to 25% of the ACR recommended dose via reconstruction of simulated shorter acquisition time per bed position scans from the acquired list data. F-18 FDG whole-body scans were reconstructed using time-of-flight OSEM algorithm and advanced system modeling. Two groups of images were obtained: group A with a standard dose of F-18 FDG and standard reconstruction parameters and group B with simulated 25% dose and modified reconstruction parameters, respectively. Three nuclear medicine physicians blinded to the simulated activity independently reviewed the images and compared diagnostic quality of images. Based on the input from the physicians, we selected optimal modified reconstruction parameters for group B. In so obtained images, all the lesions observed in the group A were visible in the group B. The tumor SUV values were different in the group A, as compared to group B, respectively. However, no significant differences were reported in the final interpretation of the images from A and B groups. In conclusion, for a small number of patients, we have demonstrated that F-18 FDG dose reduction to 25% of the ACR recommended dose, accompanied by appropriate modification of the reconstruction parameters provided adequate diagnostic quality of PET images acquired on time-of-flight PET/CT.

  20. Net-based data transfer and automatic image fusion of metabolic (PET) and morphologic (CT/MRI) images for radiosurgical planning of brain tumors

    International Nuclear Information System (INIS)

    Baum, R.P.; Przetak, C.; Schmuecking, M.; Klener, G.; Surber, G.; Hamm, K.

    2002-01-01

    Aim: The main purpose of radiosurgery in comparison to conventional radiotherapy of brain tumors is to reach a higher radiation dose in the tumor and sparing normal brain tissue as much as possible. To reach this aim it is crucial to define the target volume extremely accurately. For this purpose, MRI and CT examinations are used for radiotherapy planning. In certain cases, however, metabolic information obtained by positron emission tomography (PET) may be useful to achieve a higher therapeutic accuracy by sparing important brain structures. This can be the case, i.e. in low grade astrocytomas for exact delineation of vital tumor as well as in differentiating scaring tissue from tumor recurrence and edema after operation. For this purpose, radiolabeled aminoacid analogues (e.g. C-11 methionine) and recently O-2-[ 18 F] Fluorethyl-L-Tyrosin (F-18 FET) have been introduced as PET tracers to detect the area of highest tumor metabolism which allows to obtain additional information as compared to FDG-PET that reflects the local glucose metabolism. In these cases, anatomical and metabolic data have to be combined with the technique of digital image fusion to exactly determine the target volume, the isodoses and the area where the highest dose has to be applied. Materials: We have set up a data transfer from the PET Center of the Zentralklinik Bad Berka with the Department of Stereotactic Radiation at the Helios Klinik Erfurt (distance approx. 25 km) to enable this kind of image fusion. PET data (ECAT EXACT 47, Siemens/CTI) are transferred to a workstation (NOVALIS) in the Dept. of Stereotactic Radiation to be co-registered with the CT or MRI data of the patient. All PET images are in DICOM format (obtained by using a HERMES computer, Nuclear Diagnostics, Sweden) and can easily be introduced into the NOVALIS workstation. The software uses the optimation of mutual information to achieve a good fusion quality. Sometimes manual corrections have to be performed to get an

  1. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  2. In vivo tumor-targeted dual-modal fluorescence/CT imaging using a nanoprobe co-loaded with an aggregation-induced emission dye and gold nanoparticles.

    Science.gov (United States)

    Zhang, Jimei; Li, Chan; Zhang, Xu; Huo, Shuaidong; Jin, Shubin; An, Fei-Fei; Wang, Xiaodan; Xue, Xiangdong; Okeke, C I; Duan, Guiyun; Guo, Fengguang; Zhang, Xiaohong; Hao, Jifu; Wang, Paul C; Zhang, Jinchao; Liang, Xing-Jie

    2015-02-01

    As an intensely studied computed tomography (CT) contrast agent, gold nanoparticle has been suggested to be combined with fluorescence imaging modality to offset the low sensitivity of CT. However, the strong quenching of gold nanoparticle on fluorescent dyes requires complicated design and shielding to overcome. Herein, we report a unique nanoprobe (M-NPAPF-Au) co-loading an aggregation-induced emission (AIE) red dye and gold nanoparticles into DSPE-PEG(2000) micelles for dual-modal fluorescence/CT imaging. The nanoprobe was prepared based on a facile method of "one-pot ultrasonic emulsification". Surprisingly, in the micelles system, fluorescence dye (NPAPF) efficiently overcame the strong fluorescence quenching of shielding-free gold nanoparticles and retained the crucial AIE feature. In vivo studies demonstrated the nanoprobe had superior tumor-targeting ability, excellent fluorescence and CT imaging effects. The totality of present studies clearly indicates the significant potential application of M-NPAPF-Au as a dual-modal non-invasive fluorescence/X-ray CT nanoprobe for in vivo tumor-targeted imaging and diagnosis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. CT findings of skull tumors forming subcutaneous masses

    International Nuclear Information System (INIS)

    Niida, Hirohito; Takeda, Norio; Onda, Kiyoshi; Tanaka, Ryuichi

    1991-01-01

    Some characteristics of CT findings in 27 patients with skull tumors forming subcutaneous tumors were studied. There were sixteen metastatic skull tumors, six primary skull tumors, and five meningiomas. A CT scan was found to be helpful in the diagnosis of the lesions. Especially, bone-window CT images proved very sensitive in the detection of destructive and permeative lesions of the skull. In 19 of the 27 cases, some lytic lesions were observed. In all cases with skull metastasis from carcinomas, a complete osteolytic change of the skull was observed. Furthermore, all of the metastatic tumors from thyroid carcinoma showed well circumscribed and homogeneously enhanced lesions, in contrast with the other metastatic carcinomas, which usually showed heterogeneously enhanced lesions with irregular margins. Osteoblastic changes were characteristically observed in all cases of meningiomas, osteosarcoma, and chondrosarcoma. Meningiomas were located mainly in the intracranial region and extended extracranially. In one case of malignant lymphoma, one of a neuroblastoma, and one of leukemia, there was little or no gross cortical bone change, despite a large mass. (author)

  4. Analysis on CT features of tumor-like gastric schwannomas

    International Nuclear Information System (INIS)

    Zhang Yu; Chen Jie

    2011-01-01

    Objective: To analyze CT imaging features of tumor-like gastric schwannomas. Methods: Ten patients with gastric schwannomas were retrospectively analyzed. All were scanned with pre-and pro-enhanced CT. Analysis of the CT findings included evaluation of the volume, number, location, contour, growth pattern, border, enhancement pattern, and enhancement grade as well as the presence of surface dimpling, integrity of overlying mucosa. All cases were confirmed by pathology. Results: In every case, simple tumor was present. The largest was about 5.7 cm in the diameter, the smallest was 2.3 cm. All tumors were round or oval, and one tumor was slightly lobulated. Endoluminal growth pattern was defined in two cases, exoluminal growth pattern was defined in one case, and a mixed growth pattern was noted in the rest. The borders of tumors were clear. In arterial phase, no visible enhancement was present in eight cases and mild enhancement in two cases. All cases were constantly enhanced in portal phase. Superficial ulcers were present in four cases. Conclusion: CT findings of tumor-like gastric schwannomas are distinctive to a certain degree. It can be used to guide clinical therapy. (authors)

  5. Dendrimer-Stabilized Gold Nanostars as a Multifunctional Theranostic Nanoplatform for CT Imaging, Photothermal Therapy, and Gene Silencing of Tumors.

    Science.gov (United States)

    Wei, Ping; Chen, Jingwen; Hu, Yong; Li, Xin; Wang, Han; Shen, Mingwu; Shi, Xiangyang

    2016-12-01

    Development of versatile nanomaterials combining diagnostic and therapeutic functionalities within one single nanoplatform is extremely important for tumor theranostics. In this work, the authors report the synthesis of a gold nanostar (Au NS)-based theranostic platform stabilized with cyclic arginine-glycine-aspartic (Arg-Gly-Asp, RGD) peptide-modified amine-terminated generation 3 poly(amidoamine) dendrimers. The formed RGD-modified dendrimer-stabilized Au NSs (RGD-Au DSNSs) are used as a gene delivery vector to complex small interfering RNA (siRNA) for computed tomography (CT) imaging, thermal imaging, photothermal therapy (PTT), and gene therapy of tumors. The results show that the RGD-Au DSNSs are able to compact vascular endothelial growth factor siRNA and specifically deliver siRNA to cancer cells overexpressing α v β 3 integrin. Under near-infrared laser irradiation, the viability of cancer cells is only 20.2% after incubation with the RGD-Au DSNS/siRNA polyplexes, which is much lower than that of cells after single PTT or gene therapy treatment. Furthermore, in vivo results show that the RGD-Au DSNS/siRNA polyplexes enable tumor CT imaging, thermal imaging, PTT, and gene therapy after intratumoral injection. These results indicate that the developed multifunctional nanoconstruct is a promising platform for tumor imaging and combinational PTT and gene therapy. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Diagnosis of intracranial mixed tumor with CT and MRI (report of 7 cases)

    International Nuclear Information System (INIS)

    Guan Changqun; Zhou Huaiwei; Xue Hongli; Zhang Yuzhong; Hu Lianyuan

    1998-01-01

    Purpose: To recognize the images of intracranial mixed tumor. Materials and methods: Seven cases were studied with CT and MRI. All were proved by pathology, including mixed tumor of meningioma with glioblastoma 2 cases, meningioma with pituitary tumor 2 cases, glioblastoma multiform with angioblastoma 1 cases, cholesteatoma with melanoma 1 case, and pituitary tumor with meningioma 1 case. The authors analysed the CT and MRI manifestations of intracranial mixed tumor retrospectively. Results: The CT and MRI manifestations of intracranial mixed tumor were exactly like meningioma, glioma, and hypophysoma, etc, therefore it was usually misdiagnosed the common tumor. Four cases intracranial mixed tumor displayed two kinds of characteristic CT and MRI manifestation on the same region of the same tumor in contrast with the clinic and pathologic change. Conclusion: There were no characteristic CT and MRI manifestations; the diagnosis should be made in combination with clinical information

  7. 3D tumor measurement in cone-beam CT breast imaging

    Science.gov (United States)

    Chen, Zikuan; Ning, Ruola

    2004-05-01

    Cone-beam CT breast imaging provides a digital volume representation of a breast. With a digital breast volume, the immediate task is to extract the breast tissue information, especially for suspicious tumors, preferably in an automatic manner or with minimal user interaction. This paper reports a program for three-dimensional breast tissue analysis. It consists of volumetric segmentation (by globally thresholding), subsegmentation (connection-based separation), and volumetric component measurement (volume, surface, shape, and other geometrical specifications). A combination scheme of multi-thresholding and binary volume morphology is proposed to fast determine the surface gradients, which may be interpreted as the surface evolution (outward growth or inward shrinkage) for a tumor volume. This scheme is also used to optimize the volumetric segmentation. With a binary volume, we decompose the foreground into components according to spatial connectedness. Since this decomposition procedure is performed after volumetric segmentation, it is called subsegmentation. The subsegmentation brings the convenience for component visualization and measurement, in the whole support space, without interference from others. Upon the tumor component identification, we measure the following specifications: volume, surface area, roundness, elongation, aspect, star-shapedness, and location (centroid). A 3D morphological operation is used to extract the cluster shell and, by delineating the corresponding volume from the grayscale volume, to measure the shell stiffness. This 3D tissue measurement is demonstrated with a tumor-borne breast specimen (a surgical part).

  8. 3D-CT imaging processing for qualitative and quantitative analysis of maxillofacial cysts and tumors

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti, Marcelo de Gusmao Paraiso [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Radiologia; Antunes, Jose Leopoldo Ferreira [Sao Paulo Univ., SP (Brazil). Faculdade de Odotologia. Dept. de Odontologia Social

    2002-09-01

    The objective of this study was to evaluate spiral-computed tomography (3D-CT) images of 20 patients presenting with cysts and tumors in the maxillofacial complex, in order to compare the surface and volume techniques of image rendering. The qualitative and quantitative appraisal indicated that the volume technique allowed a more precise and accurate observation than the surface method. On the average, the measurements obtained by means of the 3D volume-rendering technique were 6.28% higher than those obtained by means of the surface method. The sensitivity of the 3D surface technique was lower than that of the 3D volume technique for all conditions stipulated in the diagnosis and evaluation of lesions. We concluded that the 3D-CT volume rendering technique was more reproducible and sensitive than the 3D-CT surface method, in the diagnosis, treatment planning and evaluation of maxillofacial lesions, especially those with intra-osseous involvement. (author)

  9. 3D-CT imaging processing for qualitative and quantitative analysis of maxillofacial cysts and tumors

    International Nuclear Information System (INIS)

    Cavalcanti, Marcelo de Gusmao Paraiso; Antunes, Jose Leopoldo Ferreira

    2002-01-01

    The objective of this study was to evaluate spiral-computed tomography (3D-CT) images of 20 patients presenting with cysts and tumors in the maxillofacial complex, in order to compare the surface and volume techniques of image rendering. The qualitative and quantitative appraisal indicated that the volume technique allowed a more precise and accurate observation than the surface method. On the average, the measurements obtained by means of the 3D volume-rendering technique were 6.28% higher than those obtained by means of the surface method. The sensitivity of the 3D surface technique was lower than that of the 3D volume technique for all conditions stipulated in the diagnosis and evaluation of lesions. We concluded that the 3D-CT volume rendering technique was more reproducible and sensitive than the 3D-CT surface method, in the diagnosis, treatment planning and evaluation of maxillofacial lesions, especially those with intra-osseous involvement. (author)

  10. CT image construction of a totally deflated lung using deformable model extrapolation

    International Nuclear Information System (INIS)

    Sadeghi Naini, Ali; Pierce, Greg; Lee, Ting-Yim

    2011-01-01

    Purpose: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. Methods: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. Results: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The

  11. Dual tracer functional imaging of gastroenteropancreatic neuroendocrine tumors using 68Ga-DOTA-NOC PET-CT and 18F-FDG PET-CT: competitive or complimentary?

    Science.gov (United States)

    Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.

  12. An algorithm for 4D CT image sorting using spatial continuity.

    Science.gov (United States)

    Li, Chen; Liu, Jie

    2013-01-01

    4D CT, which could locate the position of the movement of the tumor in the entire respiratory cycle and reduce image artifacts effectively, has been widely used in making radiation therapy of tumors. The current 4D CT methods required external surrogates of respiratory motion obtained from extra instruments. However, respiratory signals recorded by these external makers may not always accurately represent the internal tumor and organ movements, especially when irregular breathing patterns happened. In this paper we have proposed a novel automatic 4D CT sorting algorithm that performs without these external surrogates. The sorting algorithm requires collecting the image data with a cine scan protocol. Beginning with the first couch position, images from the adjacent couch position are selected out according to spatial continuity. The process is continued until images from all couch positions are sorted and the entire 3D volume is produced. The algorithm is verified by respiratory phantom image data and clinical image data. The primary test results show that the 4D CT images created by our algorithm have eliminated the motion artifacts effectively and clearly demonstrated the movement of tumor and organ in the breath period.

  13. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  14. Optimization of input parameters of supra-threshold stochastic resonance image processing algorithm for the detection of abdomino-pelvic tumors on PET/CT scan

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Saroha, Kartik; Patel, C.D.; Bal, C.S.; Kumar, Rakesh

    2016-01-01

    Administration of diuretics increases the urine output to clear radioactive urine from kidneys and bladder. Hence post-diuretic pelvic PET/CT scan enhances the probability of detection of abdomino-pelvic tumor. However, it causes discomfort in patients and has some side effects also. Application of supra threshold stochastic resonance (SSR) image processing algorithm on Pre-diuretic PET/CT scan may also increase the probability of detection of these tumors. Amount of noise and threshold are two variable parameters that effect the final image quality. This study was conducted to investigate the effect of these two variable parameters on the detection of abdomen-pelvic tumor

  15. SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dengwang [Shandong Normal University, Jinan, Shandong Province (China); Wang, Qinfen [Shandong Normal University, Jinan, Shandong (China); Li, H; Chen, J [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2014-06-01

    Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity

  16. Multimodality functional imaging of spontaneous canine tumors using 64Cu-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    International Nuclear Information System (INIS)

    Hansen, Anders E.; Kristensen, Annemarie T.; Law, Ian; McEvoy, Fintan J.; Kjær, Andreas; Engelholm, Svend A.

    2012-01-01

    Purpose: To compare the distribution and uptake of the hypoxia tracer 64 Cu-diacetyl-bis(N 4 -methylthiosemicarbazone) ( 64 Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition 64 Cu-ATSM distribution over time was evaluated. Methods and materials: Nine spontaneous cancer-bearing dogs were prospectively enrolled. FDG (1 h pi.) and 64 Cu-ATSM (3 and 24 h pi.) PET/CT were performed over three consecutive days. DCE-pCT was performed on day 2. Tumor uptake of FDG and 64 Cu-ATSM was assessed semi-quantitatively and the distribution of FDG, 64 Cu-ATSM and CT perfusion parameters correlated. Results: 64 Cu-ATSM distribution on scans performed 24 h apart displayed moderate to strong correlation; however, temporal changes were observed. The spatial distribution pattern of 64 Cu-ATSM between scans was moderately to strongly positively correlated to FDG, whereas the correlation of CT perfusion parameters to FDG and to 64 Cu-ATSM yielded more varying results. Conclusions: 64 Cu-ATSM uptake was positively correlated to FDG. 64 Cu-ATSM was found to be relatively stable between PET scans performed at different time points, important temporal changes were however observed in hypo-perfused regions. These findings potentially indicate that prolonged uptake periods for 64 Cu-ATSM imaging may be needed. Although a moderate to strong correlation between 64 Cu-ATSM and FDG PET/CT is observed, the two tracers provide different biological information with an overlapping spatial distribution.

  17. Diagnosis of ovarian tumors by ultrasonography and x-ray CT

    International Nuclear Information System (INIS)

    Watanabe, Hiromu

    1986-01-01

    A drawback in ultrasonography, an indispensable technique in imaging ovarian malignancies, is that it sometimes shows false positive for benign tumors including dermoid cyst and ovarian endometriosis. To overcome this, the concurrent use of X-Ray CT seems warrantable and this led us to carry out the study summarized below. CT was carried out on 268 of 322 ovarian disease cases which had undergone ultrasonography. The results obtained were as follows. Sensitivity of ultrasonography and CT in ovarian malignancies were 82 % and 88 % respectively. Of the cases subjected to both techniques, those who were deemed false positive were 39 in ultrasonography and 12 in CT. Ultrasonographic imagings of dermoid cyst and ovarian endometriosis were classified on the basis of their patterns. The results obtained revealed that those in which it was difficult to discriminate the image from ovarian malignancy were types V and VI in dermoid cyst and type III-C in ovarian endometriosis. In both dermoid cyst and ovarian endometriosis, nearly a 100 % accuracy rate was obtainable with CT for diagnosis of benign tumors. This strongly suggested that concurrent use of CT was required, in diagnosing ovarian diseases with the V or VI and III-C patterns referred to above. (author)

  18. Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Akira Toriihara

    2015-07-01

    Full Text Available Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT, magnetic resonance imaging (MRI, and dual-time-point 18F-fluorodeoxyglucose (18F-FDG positron emission tomography (PET/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the tumor showed low signal intensity on T2- weighted MRI images and non-uniform enhancement on gadolinium contrast-enhanced T1-weighted images. No increase in signal intensity was noted in diffusion-weighted images. Dual-time-point PET/CT showed markedly elevated 18F-FDG uptake, which increased from the early to delayed phase. Nevertheless, immunohistochemical analysis of the resected tumor tissue revealed weak expression of glucose transporter-1 and hexokinase II in both tumors. Temporal bone tumors, showing markedly elevated 18F-FDG uptake, which increases from the early to delayed phase on PET/CT images, may be diagnosed as malignant bone tumors. Therefore, the differential diagnosis should include chondroblastoma in combination with its characteristic findings on CT and MRI.

  19. Bone tumor imaging

    International Nuclear Information System (INIS)

    McLeod, R.A.; Berquist, T.H.

    1988-01-01

    The emphasis of this chapter is on the contribution of computed tomography (CT) and magnetic resonance imaging (MRI) to the care of patients with bone neoplasms. These modalities are emphasized because of their relative newness and not because they are considered more significant than the other more established examinations. Routine radiographs remain the most informative and essential imaging procedures for the diagnosis of bone tumors

  20. 18F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    International Nuclear Information System (INIS)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober; Middendorp, Markus; Mack, Martin; Vogl, Thomas J.; Bisdas, Sotirios

    2009-01-01

    The purpose of this paper is to evaluate the impact of adding combined 18 F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P≥0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6±18.6 ml, the mean volume derived by the MR imaging was 17.6±19.1 ml while the estimated by PET/CT volume was 18.8±18.1 ml (P≤0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  1. CT and MRI findings of 4th ventricular tumors

    International Nuclear Information System (INIS)

    Kim, Taek Geun; Ro, Hee Jeong; Byun, Jae Young; Lee, Han Jin; Chung, Myung Hee; Choi, Kyu Ho; Shinn, Kyung Sub

    1994-01-01

    The purpose of our study is to evaluate characteristic features of 4th ventricular tumors in CT and MRI. Pathologically proved 9 patients with 4th ventricular tumor were examined by CT and/or MRI. 4th ventricular tumors were ependymoma(4 cases), medulloblastoma(2 case), choroid plexus papilloma(2 cases), and oligodendroglioma(1 cases). Include in our study were only those mass lesions that were located at surgery predominantly within 4th ventricle with or without ventricular expansion. The origin of 4th ventricular tumor was the roof (ependymoma 3 cases, medulloblastoma 2 cases), the floor (ependymoma 1 cases), and the undetermined(remaining 3 case). On MRI, all tumors were hypointense except ependymoma (3 cases) showing isointensity on T1WI. All tumors were hypointense on PDWI and T2WI. On Gd-DTPA enhanced T1WI, strong enhancement was seen in all but ependymoma(1 cases) which showed mild enhancement. On CT, as compared with MR images, various density on precontrast and postcontrast images were seen. Calcification was seen in choroid plexus papilloma(1 caes) and oligodendroglioma(1 cases). Hydrocephalus is seen in all cases except ependymoma(2 cases) and oligodendroglioma(1 case). Hemorrhage within tumor was present only in ependymoma(2 cases). Cystic change or necrosis of tumor was seen in ependymoma(3 cases), choroid plexus papilloma(1 case), and oligodendroglioma(1 case). Peritumoral edema was seen in medulloblastoma(1 case). Extension through the foramen Luschka and the Megendie was seen in ependymoma (2 cases), choroid plexus(2 cases), and medulloblastoma (1 case). Seeing along the CSF pathway was seen only in ependymoma(2 case). The results od our study may suggest that specific diagnosis of 4th ventricular tumor can be suggested preoperatively by analysing the origin in 4th ventricle, difference of CT density or MRI signal intensity, presence of extension or seeding through cerebrospinal fluid of the lesion

  2. Functioning islet cell tumor of the pancreas. Localization with dynamic spiral CT

    International Nuclear Information System (INIS)

    Chung, M.J.; Choi, B.I.; Han, J.K.; Chung, J.W.; Han, M.C.; Bae, S.H.

    1997-01-01

    Purpose: The purpose of this study was to evaluate the usefulness of dynamic spiral CT, including multidimensional reformation, in the detection and localization of islet cell tumors of the pancreas. Material and Methods: Seven patients with histopathologically proven functioning islet cell tumors of the pancreas were studied with 2-phase contrast-enhanced spiral CT. Scanning of the arterial phase and late phase was started 30 s and 180 s, respectively, after injection of 100 ml of contrast medium at a rate of 3 ml/s. Results: Axial images in the arterial phase depicted the lesions in 5 patients, but in the late phase in only one patient. Multiplanar reformatted images of the arterial phase depicted the lesions in all 7 patients. Maximal intensity projection images demonstrated all lesions with information of their relationship to the vascular structure. Conclusion: Dynamic spiral CT with scanning during the arterial phase and retrospective multidimensional reformation is useful for preoperative detection and localization of small islet cell tumors of the pancreas. (orig.)

  3. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  4. Generalities of anomalous CT chest non tumoral

    International Nuclear Information System (INIS)

    Dibarboure, L.

    2012-01-01

    This presentation is about the generalities of multidetector CT in the pulmonary, the diaphragmatic, the pleural and the mediastinum pathology.These techniques as well as the virtual endoscopy allow visualize volumetric thorax reconstructions, brain diseases, opacities, radiolucent images, respiratory and vascular diseases, pneumonia, embolism, AIDS stage, tuberculosis, tumors, etc

  5. Preoperative CT prediction for Masaoka staging of thymic epithelial tumor

    International Nuclear Information System (INIS)

    Feng Zhan; Huang Zhen; Zhang Liang

    2013-01-01

    Objective: To discuss the value of CT prognosis on the Masaoka staging system of thymic epithelial tumors (TET) before surgical resection. Methods: The CT images of 102 patients with TET proved by surgery and pathology were reviewed retrospectively. The TET were reclassified according to Masaoka stage system. The size, homogeneity, sharp, contour, infiltration of surrounding tissue, and metastasis on CT were analyzed with Logistic analysis. The diagnostic value was also evaluated with a ROC curve. Results: Masaoka pathologic stages were stage Ⅰ for 36 (35.3 %), stage Ⅱ for 27 (26.5 %), stage Ⅲ for 30 (29.4 %), and stage Ⅳ for 9 (8.8 %). A multivariable Logistic regression model showed that TET with larger size of tumor (20/35, P = 0.0371, OR = 4.539), irregular or lobulated tumor contour (26/42, P = 0.0230, OR = 4.870), heterogeneous (21/33, P = 0.0154, OR = 6.020), infiltration of surrounding fat (25/32, P = 0.0019, OR = 14.005), and pleural seeding (11/11, P = 0.0032, OR = 36.153) were more likely to have stage Ⅲ or Ⅳ disease. The area under ROC curve was 0.940. Conclusions: The tumor CT imaging features can differentiate between stage Ⅰ, Ⅱ and stage Ⅲ, Ⅳ disease. This helps identified patients more likely to benefit from neoadjuvant therapy. (authors)

  6. Target Coverage in Image-Guided Stereotactic Body Radiotherapy of Liver Tumors

    International Nuclear Information System (INIS)

    Wunderink, Wouter; Romero, Alejandra Mendez; Osorio, Eliana M. Vasquez; Boer, Hans C.J. de; Brandwijk, Rene P.; Levendag, Peter C.; Heijmen, Ben

    2007-01-01

    Purpose: To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. Methods and Materials: By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV + ) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV + , derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Results: Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (≥99%) ITV + coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (≤2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Conclusion: Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging

  7. Bone tumors of the pediatric foot: imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Navarro, Oscar M. [University of Toronto, Department of Medical Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2017-05-15

    Tumors of the foot are rare in children. This review illustrates radiographic, CT and MR imaging findings of foot bone tumors in children based on all cases presented in a tertiary pediatric hospital during the 15-year period of 1999-2014. This search revealed 155 tumors of the foot, 72 of the bones and 83 of the soft tissues. Osteochondroma, bone cyst and fibrous dysplasia were the most frequent benign bone lesions. Ewing sarcoma was the most common malignant osseous tumor. Some tumors showed higher prevalence in certain age ranges and others showed predilection for specific bones. Radiographs are useful for diagnosis in the majority of cases but CT and MR imaging provide additional valuable information in select cases for diagnosis and determining extent of the lesions. Radiologists should be aware of some typical imaging findings in bone tumors of the foot in order to establish diagnosis and facilitate patient management. (orig.)

  8. TU-H-CAMPUS-JeP2-02: Interobserver Variability of CT, PET-CT and MRI Based Primary Tumor Delineation for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Karki, K; Hugo, G; Saraiya, S; Jan, N; Schuster, J; Schutzer, M; Fahrner, L; Groves, R; Ford, J; Weiss, E [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: Target delineation in lung cancer radiotherapy has, in general, large variability. MRI has so far not been investigated in detail for lung cancer delineation variability. The purpose of this study is to investigate delineation variability for lung tumors using MRI and compare it to CT alone and PET-CT based delineations. Methods: Seven physicians delineated the primary tumor volumes of nine patients for the following scenarios: (1) CT only; (2) post-contrast T1-weighted MRI registered with diffusion-weighted MRI; and (3) PET-CT fusion images. To compute interobserver variability, the median surface was generated from all observers’ contours and used as the reference surface. A single physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest-wall) on the median surface. Volume variation (normalized to PET-CT volume), minimum distance (MD), and bidirectional local distance (BLD) between individual observers’ contours and the reference contour were measured. Results: CT- and MRI-based normalized volumes were 1.61±0.76 (mean±SD) and 1.38±0.44, respectively, both significantly larger than PET-CT (p<0.05, paired t-test). The overall uncertainty (root mean square of SD values over all points) of both BLD and MD measures of the observers for the interfaces were not significantly different (p>0.05, two-samples t-test) for all imaging modalities except between tumor-mediastinum and tumor-atelectasis in PET-CT. The largest mean overall uncertainty was observed for tumor-atelectasis interface, the smallest for tumor-mediastinum and tumor-lung interfaces for all modalities. The whole tumor uncertainties for both BLD and MD were not significantly different between any two modalities (p>0.05, paired t-test). Overall uncertainties for the interfaces using BLD were similar to using MD. Conclusion: Large volume variations were observed between the three imaging modalities. Contouring variability appeared to

  9. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    Science.gov (United States)

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (design, patient stability in the SBF should be verified with portal imaging.

  10. {sup 18}F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober [JW Goethe University, Department of Oromaxillofacial Surgery, Frankfurt (Germany); Middendorp, Markus [JW Goethe University, Department of Nuclear Medicine, Frankfurt (Germany); Mack, Martin; Vogl, Thomas J. [JW Goethe University, Department of Radiology, Frankfurt (Germany); Bisdas, Sotirios [Eberhard Karls University, Department of Neuroradiology, Tuebingen (Germany)

    2009-10-15

    The purpose of this paper is to evaluate the impact of adding combined {sup 18}F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P{>=}0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6{+-}18.6 ml, the mean volume derived by the MR imaging was 17.6{+-}19.1 ml while the estimated by PET/CT volume was 18.8{+-}18.1 ml (P{<=}0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  11. Characterization of tumor heterogeneity using dynamic contrast enhanced CT and FDG-PET in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Elmpt, Wouter van; Das, Marco; Hüllner, Martin; Sharifi, Hoda; Zegers, Catharina M.L.; Reymen, Bart; Lambin, Philippe; Wildberger, Joachim E.; Troost, Esther G.C.; Veit-Haibach, Patrick; De Ruysscher, Dirk

    2013-01-01

    Purpose: Dynamic contrast-enhanced CT (DCE-CT) quantifies vasculature properties of tumors, whereas static FDG-PET/CT defines metabolic activity. Both imaging modalities are capable of showing intra-tumor heterogeneity. We investigated differences in vasculature properties within primary non-small cell lung cancer (NSCLC) tumors measured by DCE-CT and metabolic activity from FDG-PET/CT. Methods: Thirty three NSCLC patients were analyzed prior to treatment. FDG-PET/CT and DCE-CT were co-registered. The tumor was delineated and metabolic activity was segmented on the FDG-PET/CT in two regions: low (<50% maximum SUV) and high (⩾50% maximum SUV) metabolic uptake. Blood flow, blood volume and permeability were calculated using a maximum slope, deconvolution algorithm and a Patlak model. Correlations were assessed between perfusion parameters for the regions of interest. Results: DCE-CT provided additional information on vasculature and tumor heterogeneity that was not correlated to metabolic tumor activity. There was no significant difference between low and high metabolic active regions for any of the DCE-CT parameters. Furthermore, only moderate correlations between maximum SUV and DCE-CT parameters were observed. Conclusions: No direct correlation was observed between FDG-uptake and parameters extracted from DCE-CT. DCE-CT may provide complementary information to the characterization of primary NSCLC tumors over FDG-PET/CT imaging

  12. Magnetic resonance imaging in brain-stem tumors

    International Nuclear Information System (INIS)

    Nomura, Mikio; Saito, Hisazumi; Akino, Minoru; Abe, Hiroshi.

    1988-01-01

    Four patients with brain-stem tumors underwent magnetic resonance imaging (MRI) before and after radiotherapy. The brain-stem tumors were seen as a low signal intensity on T1-weighted images and as a high signal intensity on T2-weighted images. A tumor and its anatomic involvement were more clearly visualized on MRI than on cuncurrently performed CT. Changes in tumor before and after radiotherapy could be determined by measuring the diameter of tumor on sagittal and coronal images. This allowed quantitative evaluation of the reduction of tumor in association with improvement of symptoms. The mean T1 value in the central part of tumors was shortened in all patients after radiotherapy. The results indicate that MRI may assist in determining the effect of radiotherapy for brain-stem tumors. (Namekawa, K)

  13. The Serum CA-125 Concentration Data Assists in Evaluating CT Imaging Information When Used to Differentiate Borderline Ovarian Tumor from Malignant Epithelial Ovarian Tumors

    International Nuclear Information System (INIS)

    Shin, Ji Eun; Choi, Hyuck Jae; Kim, Mi Hyun; Cho, Kyoung Sik

    2011-01-01

    We wanted to evaluate the diagnostic value of serum CA-125 concentration, when used in combination with the preoperative contrast-enhanced CT results, to differentiate borderline ovarian tumors (BOTs) from stage I malignant epithelial ovarian tumors (MEOTs). Ninety-eight masses (46 BOTs and 52 stage I MEOTs) from 87 consecutive patients (49 with BOTs and 38 with stage I MEOTs) who had undergone preoperative contrast-enhanced computed tomography (CT) and surgical staging were evaluated retrospectively and independently by two radiologists. The preoperative serum CA-125 concentration was measured in all patients. The utility of analyzing serum CA-125 concentration in combination with the CT results was evaluated by receiver operating characteristic (ROC) curve analysis. An irregular tumor surface and lymphadenopathy were predictive of a MEOT. ROC analysis showed that the combination of CT data and the serum CA-125 level resulted in a higher diagnostic performance than did using the CT alone for differentiating BOTs from MEOTs. The areas under the curves (AUCs) without and with the use of the serum CA-125 level data were 0.67 (95% confidence interval [CI]: 0.57-0.77) and 0.78 (95% CI: 0.68-0.85), respectively, for reader 1 (p = 0.029) and 0.71 (95% CI: 0.61-0.80) and 0.81 (95% CI: 0.72-0.89), respectively, for reader 2 (p = 0.009). The serum CA-125 concentration is of additional diagnostic value when used in conjunction with the CT imaging results for differentiating BOTs from MEOTs.

  14. Is There an Additional Value of 11C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

    International Nuclear Information System (INIS)

    Van den Bergh, Laura; Koole, Michel; Isebaert, Sofie; Joniau, Steven; Deroose, Christophe M.; Oyen, Raymond; Lerut, Evelyne; Budiharto, Tom; Mottaghy, Felix; Bormans, Guy; Van Poppel, Hendrik; Haustermans, Karin

    2012-01-01

    Purpose: To investigate the additional value of 11 C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and 11 C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze 11 C-choline PET-CT images, the same grid was used to calculate the standardized uptake values (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For 11 C-choline PET-CT, the mean SUV max of malignant octants was significantly higher than the mean SUV max of benign octants (3.69 ± 1.29 vs. 3.06 ± 0.97, p mean values (2.39 ± 0.77 vs. 1.94 ± 0.61, p mean and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV max cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV max but at the cost of specificity. When only considering suspect octants on 11 C-choline PET-CT (SUV max ≥ 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value of 11 C-choline PET-CT next to T2w MRI in detecting tumor nodules within the prostate is limited.

  15. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  16. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  17. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  18. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  19. Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Starkschall, George; Prado, Karl; Dong Lei; Balter, Peter

    2010-01-01

    Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

  20. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  1. Primary cardiac and pericardial tumors, imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    The incidence of cardiac tumor and its classification was discussed. Imaging study i.e. conventional radiology, echocardiagoaphy (echo), magnetic resonance imaging (MRI), angiography and computed tomography (CT) used also discussed briefly. (8 refs.).

  2. Primary cardiac and pericardial tumors, imaging approach

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    The incidence of cardiac tumor and its classification was discussed. Imaging study i.e. conventional radiology, echocardiagoaphy (echo), magnetic resonance imaging (MRI), angiography and computed tomography (CT) used also discussed briefly. (8 refs.)

  3. Gastric stromal tumor: two-phase dynamic CT findings with water as oral contrast agents

    International Nuclear Information System (INIS)

    Lee, Se Hyo; Cho, June Sik; Shin, Kyung Sook; Jeong, Ki Ho; Park, Jin Yong; Yu, Ho Jun; Kim, Young Min; Jeon, Kwang Jin

    2000-01-01

    To evaluate two-phase dynamic CT with water as oral contrast agents in the CT diagnosis of gastric stromal tumors. We retrospectively reviewed the CT findings in 21 patients with pathologically proven gastric stromal tumors. Six were found to be benign, twelve were malignant, and there were three cases of STUMP (stromal tumor uncertain malignant potential). Two-phase dynamic CT scans with water as oral contrast agents were obtained 60-70 secs (portal phase) and 3 mins (equilibrium phase) after the start of IV contrast administration. We determined the size, growth pattern, and enhancement pattern of the tumors and overlying mucosa, the presence or absence of ulceration and necrosis, tumor extent, and lymph nod and distant metastasis. The CT and pathologic findings were correlated. All six benign tumors and three STUMP were less than 5.5 cm in size, and during the portal phase showed round endogastric masses with highly enhanced, intact overlying mucosa. Twelve malignant tumors were 4.5-15.5 cm in size (mean, 11.5 cm); an endogastric mass was seen in three cases, an exogastric mass in one, and a mixed pattern in eight. On portal phase images the tumors were not significantly enhanced, but highly enhanced feeding vessels were noted in five larger tumors (greater than 10 cm). All 12 malignant tumors showed ulceration and necrosis, and interruption of overlying mucosa was clearly seen during the portal phase. We were readily able to evaluate tumor extent during this phase, and in ten malignant tumors there was no invasion of adjacent organs. Seven malignant tumors showed air density within their necrotic portion (p less than 0.05). On equilibrium phase images, all malignant tumors showed heterogeneous enhancement due to necrosis, and poorly enhanced overlying mucosa. Dynamic CT during the portal phase with water as oral contrast agents was useful for depicting the submucosal origin of gastric stromal tumors and for evaluating the extent of malignant stromal tumors. Our

  4. Sequential computed tomographic imaging of a transplantable rabbit brain tumor

    International Nuclear Information System (INIS)

    Kumar, A.J.; Rosenbaum, A.E.; Beck, T.J.; Ahn, H.S.; Anderson, J.

    1986-01-01

    The accuracy of CT imaging in evaluating VX-2 tumor growth in the rabbit brain was assessed. CT scanning was performed in 5 outbred New Zealand white male rabbits before and at 4, 7, 9 and 13 (in 3 animals) days after surgical implantation of 3 x 10 5 viable VX-2 tumor cells in the frontoparietal lobes. The CT studies were correlated with gross pathology in each. The tumor was visualized with CT in all 5 rabbits by the 9th day post implantation when the tumor ranged in size from 4-6 x 3-4 x 2-3 mm. Between the 9th and 13th day, the tumor increased 6-fold in two rabbits and 12-fold in the third rabbit. CT is a useful technique to evaluate brain tumor growth in this model and should be valuable in documenting the efficacy of chemotherapy on tumor growth. (orig.)

  5. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  6. TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning

    International Nuclear Information System (INIS)

    Pan, T.

    2016-01-01

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  7. TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning

    Energy Technology Data Exchange (ETDEWEB)

    Pan, T. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  8. 18F-Fluoride PET/CT tumor burden quantification predicts survival in breast cancer.

    Science.gov (United States)

    Brito, Ana E; Santos, Allan; Sasse, André Deeke; Cabello, Cesar; Oliveira, Paulo; Mosci, Camila; Souza, Tiago; Amorim, Barbara; Lima, Mariana; Ramos, Celso D; Etchebehere, Elba

    2017-05-30

    In bone-metastatic breast cancer patients, there are no current imaging biomarkers to identify which patients have worst prognosis. The purpose of our study was to investigate if skeletal tumor burden determined by 18F-Fluoride PET/CT correlates with clinical outcomes and may help define prognosis throughout the course of the disease. Bone metastases were present in 49 patients. On multivariable analysis, skeletal tumor burden was significantly and independently associated with overall survival (p breast cancer patients (40 for primary staging and the remainder for restaging after therapy). Clinical parameters, primary tumor characteristics and skeletal tumor burden were correlated to overall survival, progression free-survival and time to bone event. The median follow-up time was 19.5 months. 18F-Fluoride PET/CT skeletal tumor burden is a strong independent prognostic imaging biomarker in breast cancer patients.

  9. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    International Nuclear Information System (INIS)

    Sweeney, Reinhart A; Seubert, Benedikt; Stark, Silke; Homann, Vanessa; Müller, Gerd; Flentje, Michael; Guckenberger, Matthias

    2012-01-01

    To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs) and three radiotherapy technicians (RTTs). Image-guidance using respiration correlated 4D-CBCT (IG-4D) with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1) manual registration of the planning internal target volume (ITV) contour and the motion blurred tumor in the 3D-CBCT (IG-ITV); 2) automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D). Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector) on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was significantly larger in IG using 3D-CBCT compared to 4D-CBCT: 0.6 mm versus 1.5 mm

  10. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors

    Directory of Open Access Journals (Sweden)

    Sweeney Reinhart A

    2012-06-01

    Full Text Available Abstract Background To analyze the accuracy and inter-observer variability of image-guidance (IG using 3D or 4D cone-beam CT (CBCT technology in stereotactic body radiotherapy (SBRT for lung tumors. Materials and methods Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs and three radiotherapy technicians (RTTs. Image-guidance using respiration correlated 4D-CBCT (IG-4D with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1 manual registration of the planning internal target volume (ITV contour and the motion blurred tumor in the 3D-CBCT (IG-ITV; 2 automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D. Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1–3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Results Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was

  11. Magnetic resonance imaging in the head and neck tumor diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Yasuyuki; Igarashi, Masahito; Miyata, Mamoru; Sonoda, Tetsushi; Miyoshi, Shunji; Hiraide, Fumihisa; Morita, Mamoru; Tanaka, Osamu

    1987-06-01

    MRI (magnetic resonance imaging) is a new diagnostic technique that is being applied to study disease processes that involve the upper aero-digestive tract and cranial nerves of interest to otolaryngologist. Seventy four patients with head and neck tumor were enrolled to study the diagnostic efficacy of MRI in comparison with X-ray computed tomography (X-ray CT). Five cases of head and neck tumors were presented. Characteristic findings of MRI were discussed. T2 weighted images are very useful in the diagnosis of head and neck tumors. Tumors in the areas surrounded by bone tissue were clearly imaged without such artifacts as recognized in X-ray CT. Information from mutiplane imaging, especially from coronal and sagittal sections, made it easier to determine the type and extent of the lesion. High signal linear parts which are in the periphery of the tumor offer important information that no adhesion is present.

  12. TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Kearney, V; Liu, H; Jiang, L; Foster, R; Mao, W [UT Southwestern Medical Center, Dallas, Texas (United States); Rozario, T; Bereg, S [University of Texas at Dallas, Richardson, Texas (United States); Klash, S [Premier Cancer Centers, Dallas, TX (United States)

    2014-06-15

    Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

  13. Peculiarities in the CT findings of germ cell tumors in various tumor localizations

    International Nuclear Information System (INIS)

    Tazoe, Makoto; Miyagami, Mitsusuke; Tsubokawa, Takashi

    1991-01-01

    The CT findings of 17 germ cell tumors were studied in relation to the locations of the tumor, the pathological diagnoses, and the tumor markers (AFP and HCG). Generally, the CT findings of germ cell tumors depended on the pathological diagnoses more strongly than on the location of the tumors. On plain CT of 7 germ cell tumors in the pineal region, all of them demonstrated heterogeneous findings. Hydrocephalus was seen in 6 cases (86%) and calcification in 6 cases (86%) of the germ cell tumors in the pineal region. Calcification and hydrocephalus that appeared more often than in other regions were characteristic of germ cell tumors of the pineal region. The germ cell tumors in the basal ganglia had a slightly homogenous high density, with small cysts and calcification in most of them on plain CT. On enhanced CT, the tumors were moderately enhanced in all cases located in the basal ganglia. Four cases of germ cell tumors located in the basal ganglia revealed the dilatation of lateral ventricle due to hemispheric atrophy in the tumor side. The germ cell tumors showing an increase in the tumor markers such as AFP and HCG, which were usually malignant germ cell tumors, were strongly enhanced on enhanced CT. (author)

  14. Imaging of pancreatic tumors with PET

    International Nuclear Information System (INIS)

    Zanzi, I.; Robeson, W.; Vinciquerra, V.; Chaly, T.; Kroop, S.; Dahl, R.; Schulman, P.; Goldman, S.; Margouleff, D.

    1990-01-01

    This paper identifies pancreatic tumors with positron emission tomography (PET) using F-18 2-fluorodeoxyglucose (FDG). PET studies were performed in 13 patients with pancreatic tumors (11 adenocarcinomas; two islet cell tumors) using FDG. Data were acquired for 1 hour and in 14 contiguous 7-mm sections after attenuation correction. Suspicious areas were evaluated using quantitative techniques. In seven of 11 patients with adenocarcinomas, focal increase in FDG uptake correlated with pancreatic tumor shown on CT scans or MR images. Of the remaining four, one had a previous Whipple procedure, another had completed chemotherapy, and in two the tumor was out of the limited region imaged; in these four patients, liver metastases were identified in three

  15. Measurement of lung tumor motion using respiration-correlated CT

    International Nuclear Information System (INIS)

    Mageras, Gig S.; Pevsner, Alex; Yorke, Ellen D.; Rosenzweig, Kenneth E.; Ford, Eric C.; Hertanto, Agung; Larson, Steven M.; Lovelock, D. Michael; Erdi, Yusuf E.; Nehmeh, Sadek A.; Humm, John L.; Ling, C. Clifton

    2004-01-01

    Purpose: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. Methods and materials: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. Results: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3

  16. Evaluation of gross tumor size using CT, 18F-FDG PET, integrated 18F-FDG PET/CT and pathological analysis in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yu Huiming; Liu Yunfang; Hou Ming; Liu Jie; Li Xiaonan; Yu Jinming

    2009-01-01

    Purpose: The correlation of gross tumor sizes between combined 18 F-FDG PET/CT images and macroscopic surgical samples has not yet been studied in detail. In the present study, we compared CT, 18 F-FDG PET and combined 18 F-FDG PET/CT for the delineation of gross tumor volume (GTV) and validated the results through examination of the macroscopic surgical specimen. Methods: Fifty-two operable non-small cell lung cancer (NSCLC) patients had integrated 18 F-FDG PET/CT scans preoperatively and pathological examination post-operation. Four separate maximal tumor sizes at X (lateral direction), Y (ventro-dorsal direction) and Z (cranio-caudal direction) axis were measured on 18 F-FDG PET, CT, combined 18 F-FDG PET/CT and surgical specimen, respectively. Linear regression was calculated for each of the three imaging measurements versus pathological measurement. Results: No significant differences were observed among the tumor sizes measured by three images and pathological method. Compared with pathological measurement, CT size at X, Y, Z axis was larger, whereas combined 18 F-FDG PET/CT and 18 F-FDG PET size were smaller. Combined 18 F-FDG PET/CT size was more similar to the pathological size than that of 18 F-FDG PET or CT. Results of linear regressions showed that integrated 18 F-FDG PET/CT was the most accurate modality in measuring the size of cancer. Conclusions: 18 F-FDG PET/CT correlates more faithfully with pathological findings than 18 F-FDG PET or CT. Integrated 18 F-FDG PET/CT is an effective tool to define the target of GTV in radiotherapy.

  17. Correlation of intra-tumor 18F-FDG uptake heterogeneity indices with perfusion CT derived parameters in colorectal cancer.

    Science.gov (United States)

    Tixier, Florent; Groves, Ashley M; Goh, Vicky; Hatt, Mathieu; Ingrand, Pierre; Le Rest, Catherine Cheze; Visvikis, Dimitris

    2014-01-01

    Thirty patients with proven colorectal cancer prospectively underwent integrated 18F-FDG PET/DCE-CT to assess the metabolic-flow phenotype. Both CT blood flow parametric maps and PET images were analyzed. Correlations between PET heterogeneity and perfusion CT were assessed by Spearman's rank correlation analysis. Blood flow visualization provided by DCE-CT images was significantly correlated with 18F-FDG PET metabolically active tumor volume as well as with uptake heterogeneity for patients with stage III/IV tumors (|ρ|:0.66 to 0.78; p-valueheterogeneity of 18F-FDG PET accumulation reflects to some extent tracer distribution and consequently indicates that 18F-FDG PET intra-tumor heterogeneity may be associated with physiological processes such as tumor vascularization.

  18. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  19. Imaging of bone tumors and tumor-like lesions. Techniques and applications

    International Nuclear Information System (INIS)

    Davies, A. Mark; Sundaram, Murali; James, Steven L.J.

    2009-01-01

    This is a comprehensive textbook that provides a detailed description of the imaging techniques and findings in patients with benign and malignant bone tumors. In the first part of the book, the various techniques and procedures employed for imaging bone tumors are discussed in detail. Individual chapters are devoted to MRI, CT, nuclear medicine, and interventional procedures. The second part of the book gives an authoritative review of the role of these imaging techniques in diagnosis, surgical staging, biopsy, and assessment of response to therapy. The third part of the book covers the imaging features of each major tumor subtype, with separate chapters on osteogenic tumors, cartilaginous tumors, etc. The final part of the book reviews the imaging features of bone tumors at particular anatomical sites such as the spine, ribs, pelvis, and scapula. Each chapter is written by an acknowledged expert in the field, and a wealth of illustrative material is included. This book will be of great value to musculoskeletal and general radiologists, orthopedic surgeons, and oncologists. (orig.)

  20. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  1. CT/FMT dual-model imaging of breast cancer based on peptide-lipid nanoparticles

    Science.gov (United States)

    Xu, Guoqiang; Lin, Qiaoya; Lian, Lichao; Qian, Yuan; Lu, Lisen; Zhang, Zhihong

    2016-03-01

    Breast cancer is one of the most harmful cancers in human. Its early diagnosis is expected to improve the patients' survival rate. X-ray computed tomography (CT) has been widely used in tumor detection for obtaining three-dimentional information. Fluorescence Molecular Tomography (FMT) imaging combined with near-infrared fluorescent dyes provides a powerful tool for the acquisition of molecular biodistribution information in deep tissues. Thus, the combination of CT and FMT imaging modalities allows us to better differentiate diseased tissues from normal tissues. Here we developed a tumor-targeting nanoparticle for dual-modality imaging based on a biocompatible HDL-mimicking peptide-phospholipid scaffold (HPPS) nanocarrier. By incorporation of CT contrast agents (iodinated oil) and far-infrared fluorescent dyes (DiR-BOA) into the hydrophobic core of HPPS, we obtained the FMT and CT signals simultaneously. Increased accumulation of the nanoparticles in the tumor lesions was achieved through the effect of the tumor-targeting peptide on the surface of nanoparticle. It resulted in excellent contrast between lesions and normal tissues. Together, the abilities to sensitively separate the lesions from adjacent normal tissues with the aid of a FMT/CT dual-model imaging approach make the targeting nanoparticles a useful tool for the diagnostics of breast cancer.

  2. CT differentiation of solid ovarian tumor and uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Rae; Cho, Kyoung Sik [Asan Medical Center, Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Sohn, Chul Ho [Dongsan Medical Center, Keimyung Univ. College of Medicine, Taegu (Korea, Republic of); Ji, Eun Kyung [Bombit Hospital, Seoul (Korea, Republic of)

    1999-06-01

    On the basis of CT findings, to differentiate between solid ovarian tumor and uterine subserosal myoma. In eight surgically proven cases of solid ovarian tumor and in ten uterine subserosal myoma patients, contrast-enhanced CT images were obtained. Two genitourinary radiologists reviewed the findings with regard to degree of enhancement of the mass as compared with enhancement of uterine myometrium, thickening of round ligaments, visualization of normal ovaries, contour of the mass, and the presence of ascites in the pelvic cavity. Six of eight ovarian tumors but only two of ten uterine myomas were less enhanced than normal uterine myometrium (p<0.05). Pelvic ascites were seen in six of eight ovarian tumors, but in only one of ten uterine myomas (P<0.05). Three of 16 ovaries in ovarian tumor patients, but 12 of 20 ovaries in uterine myoma patients, were normal (p<0.05). Six of 16 round ligaments of the uterus in ovarian tumor patients, were thichened but 11 of 20 round ligaments in uterine myoma patients, were thickened (p>0.05). The contour of the mass was lobulated in two of eight ovarian tumor patients, but in five of ten uterine myoma patients (p>0.05). CT findings suggestive of solid ovarian tumor were less contrast enhancement of the mass than of normal uterine myometrium, pelvic ascites, and nonvisualization of normal ovary.

  3. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  4. Accuracy verification of PET-CT image fusion and its utilization in target delineation of radiotherapy

    International Nuclear Information System (INIS)

    Wang Xuetao; Yu Jinming; Yang Guoren; Gong Heyi

    2005-01-01

    Objective: Evaluate the accuracy of co-registration of PET and CT (PET-CT) images on line with phantom, and utilize it on patients to provide clinical evidence for target delineation in radiotherapy. Methods: A phantom with markers and different volume cylinders was infused with various concentrations of 18 FDG, and scanned at 4 mm by PET and CT respectively. After having been transmitted into GE eNTEGRA and treatment planning system (TPS) workstations, the images were fused and reconstructed. The distance between the markers and the errors were monitored in PET and CT images respectively. The volume of cylinder in PET and CT images were measured and compared by certain pixel value proportion deduction method. The same procedure was performed on the pulmonary tumor image in ten patients. Results: eNTEGRA and TPS workstations had a good length linearity, but the fusion error of the latter was markedly greater than the former. Tumors in different volume filled by varying concentrations of 18 FDG required different pixel deduction proportion. The cylinder volume of PET and CT images were almost the same, so were the images of pulmonary tumor of ten patients. Conclusions: The accuracy of image co-registration of PET-CT on line may fulfill the clinical demand. Pixel value proportion deduction method can be used for target delineation on PET image. (authors)

  5. 90Y microsphere therapy: does 90Y PET/CT imaging obviate the need for 90Y Bremsstrahlung SPECT/CT imaging?

    Science.gov (United States)

    Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu C; Shah, Sneha A; Agrawal, Archi R; Kulkarni, Suyash S; Shetty, Nitin

    2013-11-01

    Transarterial radioembolization using Y microspheres is a novel therapeutic option for inoperable hepatic malignancies. As these spheres are radiolucent, real-time assessment of their distribution during the infusion process under fluoroscopic guidance is not possible. Bremsstrahlung radiations arising from 90Y have conventionally been used for imaging its biodistribution. Recent studies have proved that sources of 90Y also emit positrons, which can further be used for PET/computed tomography (CT) imaging. This study aimed to assess the feasibility of 90Y PET/CT imaging in evaluating microsphere distributions and to compare its findings with those of Bremsstrahlung imaging. Thirty-five sessions of 90Y microsphere transarterial radioembolization were performed on 30 patients with hepatic malignancies. 90Y PET/CT imaging was performed within 3 h of therapy. Bremsstrahlung imaging was also performed for each patient. The imaging findings were compared for concordance in the distribution of microspheres. Exact one-to-one correspondence between 90Y PET/CT imaging and 90Y Bremsstrahlung imaging was observed in 97.14% of cases (i.e. in 34/35 cases). Discordance was observed only in one case in which 90Y PET/CT imaging resolved the microsphere uptake in the inferior vena cava tumor thrombus, which was, however, not visualized on Bremsstrahlung imaging. There is good concordance in the imaging findings of 90Y PET/CT and 90Y Bremsstrahlung imaging. 90Y PET/CT imaging scores over the conventionally used Bremsstrahlung imaging in terms of better resolution, ease of technique, and comparable image acquisition time. This makes it a preferred imaging modality for assessment of the distribution of 90Y microspheres.

  6. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  7. A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Jin Jianyue; Ajlouni, Munther; Chen Qing; Yin, Fang-Fang; Movsas, Benjamin

    2006-01-01

    Background and purpose: To develop and evaluate a technique and procedure of using gated-CT images in combination with PET image to determine the internal target volume (ITV), which could reduce the planning target volume (PTV) with adequate target coverage. Patients and methods: A skin marker-based gating system connected to a regular single slice CT scanner was used for this study. A motion phantom with adjustable motion amplitude was used to evaluate the CT gating system. Specifically, objects of various sizes/shapes, considered as virtual tumors, were placed on the phantom to evaluate the number of phases of gated images required to determine the ITV while taking into account tumor size, shape and motion. A procedure of using gated-CT and PET images to define ITV for patients was developed and was tested in patients enrolled in an IRB approved protocol. Results: The CT gating system was capable of removing motion artifacts for target motion as large as 3-cm when it was gated at optimal phases. A phantom study showed that two gated-CT scans at the end of expiration and the end of inspiration would be sufficient to determine the ITV for tumor motion less than 1-cm, and another mid-phase scan would be required for tumors with 2-cm motion, especially for small tumors. For patients, the ITV encompassing visible tumors in all sets of gated-CT and regular spiral CT images seemed to be consistent with the target volume determined from PET images. PTV expanded from the ITV with a setup uncertainty margin had less volume than PTVs from spiral CT images with a 10-mm generalized margin or an individualized margin determined at fluoroscopy. Conclusions: A technique of determining the ITV using gated-CT images was developed and was clinically implemented successfully for fractionated stereotactic lung radiotherapy

  8. Multi-modality PET-CT imaging of breast cancer in an animal model using nanoparticle x-ray contrast agent and 18F-FDG

    Science.gov (United States)

    Badea, C. T.; Ghaghada, K.; Espinosa, G.; Strong, L.; Annapragada, A.

    2011-03-01

    Multi-modality PET-CT imaging is playing an important role in the field of oncology. While PET imaging facilitates functional interrogation of tumor status, the use of CT imaging is primarily limited to anatomical reference. In an attempt to extract comprehensive information about tumor cells and its microenvironment, we used a nanoparticle xray contrast agent to image tumor vasculature and vessel 'leakiness' and 18F-FDG to investigate the metabolic status of tumor cells. In vivo PET/CT studies were performed in mice implanted with 4T1 mammary breast cancer cells.Early-phase micro-CT imaging enabled visualization 3D vascular architecture of the tumors whereas delayedphase micro-CT demonstrated highly permeable vessels as evident by nanoparticle accumulation within the tumor. Both imaging modalities demonstrated the presence of a necrotic core as indicated by a hypo-enhanced region in the center of the tumor. At early time-points, the CT-derived fractional blood volume did not correlate with 18F-FDG uptake. At delayed time-points, the tumor enhancement in 18F-FDG micro-PET images correlated with the delayed signal enhanced due to nanoparticle extravasation seen in CT images. The proposed hybrid imaging approach could be used to better understand tumor angiogenesis and to be the basis for monitoring and evaluating anti-angiogenic and nano-chemotherapies.

  9. Imaging modalities in radiation treatment planning of brain tumors

    International Nuclear Information System (INIS)

    Georgiev, D.

    2009-01-01

    The radiation therapy is a standard treatment after surgery for most of malignant and some of benignant brain tumors. The restriction in acquiring local tumor control is an inability in realization of high dose without causing radiation necrosis in irradiated area and sparing normal tissues. The development of imaging modalities during the last years is responsible for better treatment results and lower early and late toxicity. Essential is the role of image methods not only in the diagnosis and also in the precise anatomical (during last years also functional) localisation, spreading of the tumor, treatment planning process and the effects of the treatment. Target delineation is one of the great geometrical uncertainties in the treatment planning process. Early studies on the use of CT in treatment planning documented that tumor coverage without CT was clearly inadequate in 20% of the patients and marginal in another 27 %. The image fusion of CT, MBI and PET and also the use of contrast materia helps to get over those restrictions. The use of contrast material enhances the signal in 10 % of the patients with glioblastoma multiform and in a higher percentage of the patients with low-grade gliomas

  10. Hyperdensity liver tumor on plain CT

    Energy Technology Data Exchange (ETDEWEB)

    Hirota, Shozo; Hanaguri, Katsuro [Kochi Municipal Central Hospital (Japan); Shimizu, Masahumi; Sako, Masao; Harada, Yasushi

    1984-12-01

    Most liver tumors on plain CT have been recognized as low density or iso-density masses. Sometimes calcified high density masses were shown on plain CT in case of cysts or metastatic liver tumors. However, hyperdensity mass of the liver on CT, of which the density was a little higher than surrounding tissues, was very rare. Recently 7 patients with hyperdensity liver masses on plain CT were experienced: 6 hepatocellular carcinomas and 1 hepatic cavernous hemangioma. A single hyperdensity mass was shown in 4 patients, a hyperdensity mass of multiple hepatic tumors was shown in 2 patients, and some hyperdensity masses of multiple hepatic tumors were shown in 1 patient. Lesions are classified in 3 types according to the appearance of hyperdensity masses: diffuse hyperdensity all over the mass, ring like hyperdensity, creascent like hyperdensity. Intravenous contrast enhancement was performed in 2 patients: one with a primary hepatocellular carcinoma, and another with a hepatic cavernous hemangioma. In the former case the tumor margin had changed unclear, in the latter case the tumor was markedly enhanced. Our results revealed that hyperdensity liver tumors were divided into 2 types: One type, shown in a cavernous hemangioma with fatty liver, demonstrated relative hyperdensity due to lower density of the surrounding tissue. Another type, shown in 6 hepatocellular carcinomas, showed hyperdensity since the density of the tumor was hyperdensity relative to the surrounding tissue of the liver. It was suggested that the tumor with the latter type had been strongly probable of malignant one, and been recommended to receive further examination. Cause of hyperdensity was thought to be due to hemorrhage, though microcalcification could not be denyed. In Japan, no hyperdensity liver tumor had been reported partly due to a wide window width with which CT photographs were taken.

  11. Magnetic resonance imaging in 38 cases of acoustic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, Masafumi; Ohtsuka, Takashi; Seiki, Yoshikatsu; Matsumoto, Mikiro; Shibata, Iekado; Terao, Hideo [Toho Univ., Tokyo (Japan). School of Medicine; Kohno, Takeshi; Sanpei, Kenji; Mano, Isamu

    1989-08-01

    The value of magnetic resonance imaging (MRI) in the diagnosis of acoustic tumors was retrospectively assessed in 38 cases. A 0.15 Tesla permanent magnet and a 1.5 Tesla superconducting magnet were employed in 24 and 14 cases, respectively. Gadolinium diethlene triamine pentaacetic acid (Gd-DTPA), a paramagnetic contrast agent, was used in 10 cases. Acoustic tumors were identified in all cases. Small, medium, and large tumors were depicted with equal clarity by MRI and computed tomography (CT). However, tumor contour and extension, accompanying cysts, and brainstem displacement were more clarly visualized on MRI. The use of Gd-DTPA improved the quality of the MR images by markedly enhancing the acoustic tumors in all cases. In particular, detection of small acoustic tumors and intra- or paratumoral cysts was facilitated by the use of Gd-DTPA. The possibility of a correlation between acoustic tumor histology and MRI features was studied by calculation of the contrast to noise (C/N) ratio in 10 cases of acoustic tumor and 7 cases of meningioma. No definite correlation was demonstrated, but there appeared to be some difference in the C/N ratio between acoustic tumors and meningiomas. In three volunteers, MRI demonstrated intracanalicular nerves, separately. Because of its higher resolution, MRI can be expected to replace CT and air CT in the diagnosis of acoustic tumors. (author).

  12. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    International Nuclear Information System (INIS)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo

    1997-01-01

    The purpose of this study was 1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and 2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20

  13. CT staging of renal pelvis tumor

    International Nuclear Information System (INIS)

    Yoon, Soo Woong; Cho, Kyoung Sik; Lee, Jong Hwa; Ham, Su Yeon; Won, Yeong Cheol; Ji, Eun Kyung; Choi, Seong Hun; Shin, Byung Suck

    1999-01-01

    To assess the value of computed tomography (CT) in the preoperative staging of transitional cell carcinoma (TCC) of the renal pelvis. We retrospectively evaluated the CT TNM staging of 38 patients with TCC of the renal pelvis who had undergone preoperative abdominal CT examination between January 1990 and January 1998. In CT staging for differentiation between early-stage (T0-2) and advanced-stage disease (T3-T4), three criteria were used, namely the presence or obliteration of the renal sinus fat layer, the smoothness or irregularity of margin between the tumor and renal parenchyma, and the presence or absence of hydronephrosis proximal to the tumor. CT staging was performed by two genitourinary radiologists blinded to the pathologic results, and was compared with pathologic staging. Pathologic results revealed 19 cases of early stage disease (T0=8, T1=9, T2=2) and 19 of advanced stage (T3=12, T4=7). Overall CT staging accuracy was 82%(31/38) ; four cases were overstaged and three were understaged. In early-stage disease, sensitivity and specificity were 79%, and 84%, and in advanced stage disease were 83% and 80%. Three of four overstaged cases showed hydronephrosis proximal to the tumor. In the second CT staging, using proximal hydronephrosis of the tumor as a criterion for early-stage disease, the sensitivity and specificity of early-stage disease were 95% and 75%, respectively, and the specificity of advanced-stage disease was 95%. When hydronephrosis proximal to a tumor was considered to be a sign of early stage disease, the CT staging of renal pelvic TCC was highly accurate

  14. PEGylated (NH4)xWO3 nanorods as efficient and stable multifunctional nanoagents for simultaneous CT imaging and photothermal therapy of tumor.

    Science.gov (United States)

    Macharia, Daniel K; Tian, Qiyun; Chen, Liang; Sun, Yingqi; Yu, Nuo; He, Chuanglong; Wang, Han; Chen, Zhigang

    2017-09-01

    The simultaneous imaging and photothermal therapy of tumors have attracted much attention, and a prerequisite is to obtain multifunctional nanomaterials. Ideally, one kind of nanoparticles with single component can be used as both imaging agent and photothermal agent. Herein, we have developed the PEGylated (NH 4 ) x WO 3 (denoted as (NH 4 ) x WO 3 -PEG) nanorods as multifunctional nanoparticles with single semiconductor component. (NH 4 ) x WO 3 -PEG nanorods with about 30nm diameter and length of several hundred nanometers have been obtained through a solvothermal synthesis-PEGylation two-step route. Under the irradiation of 980-nm laser with intensity of 0.72Wcm -2 , aqueous dispersion of (NH 4 ) x WO 3 -PEG nanorods (0.67-5.44mmol/L) displays high elevation (17.6-34.5°C) of temperature in 400s, accompanied by an excellent long-term photothermal stability. Furthermore, (NH 4 ) x WO 3 -PEG nanorods exhibit as high as 6 times X-ray attenuation ability compared to that of the clinically used iodine-based X-ray computed tomography (CT) contrast agent (Iopromide). More importantly, after PBS solution of (NH 4 ) x WO 3 -PEG nanorods is injected into the tumor of mice, the tumor can be effectively detected by CT imaging. Moreover, cancer cells in vivo can be further destroyed by the photothermal effects of (NH 4 ) x WO 3 -PEG nanorods, under the irradiation of 980-nm laser with the safe intensity of 0.72Wcm -2 for 10min. Therefore, (NH 4 ) x WO 3 -PEG nanorods can be used as a new kind of stable and efficient multifunctional nanoagent with single component for simultaneous CT imaging and photothermal therapy of tumor. Copyright © 2017. Published by Elsevier B.V.

  15. Creation and evaluation of complementary composite three-dimensional image in various brain diseases. An application of three-dimensional brain SPECT image and three-dimensional CT image

    International Nuclear Information System (INIS)

    Seiki, Yoshikatsu; Shibata, Iekado; Mito, Toshiaki; Sugo, Nobuo

    2000-01-01

    The purpose of this study was to develop 3D composite images for use in functional and anatomical evaluation of various cerebral pathologies. Imaging studies were performed in normal volunteers, patients with hydrocephalus and patients with brain tumor (meningioma and metastatic tumor) using a three-detector SPECT system (Prism 3000) and helical CT scanner (Xvigor). 123 I-IMP was used in normal volunteers and patients with hydrocephalus, and 201 TLCL in patients with brain tumor. An Application Visualization System-Medical Viewer (AVS-MV) was used on a workstation (Titan 2) to generate 3D images. A new program was developed by synthesizing surface rendering and volume rendering techniques. The clinical effects of shunt operations were successfully evaluated in patients with hydrocephalus by means of translucent 3D images of the deep brain. Changes in the hypoperfusion area around the cerebral ventricle were compared with morphological changes in the cerebral ventricle on CT. In addition to the information concerning the characteristics of brain tumors and surrounding edemas, hemodynamic changes and changeable hypoperfusion areas around the tumors were visualized on 3D composite CT and SPECT images. A new method of generating 3D composite images of CT and SPECT was developed by combining graphic data from different systems on the same workstation. Complementary 3D composite images facilitated quantitative analysis of brain volume and functional analysis in various brain diseases. (author)

  16. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    Science.gov (United States)

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  17. MR imaging assisted radiation therapy planning of brain tumors

    International Nuclear Information System (INIS)

    Just, M.; Roesler, H.P.; Higer, H.P.; Kutzner, J.; Thelen, M.

    1990-01-01

    This paper reports on the improvement of the accuracy of treatment portals in radiation therapy of brain tumors with use of MR imaging. After proper processing, the parasagittal MR image showing the largest tumor size and the midline sagittal image were superimposed. With common anatomic landmarks of midline tomogram and lateral simulation radiograph, commensurate reference grids were laid over both images in identical positions. Tumor coordinates were then transferred from the synthesized MR image to the lateral radiograph. Rectangular fields or individual shielding blocks encompassing the tumor could be drawn directly. This new method was used in 17 patients, and results were compared with CT-assisted results

  18. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  19. Comparison of applied dose and image quality in staging CT of neuroendocrine tumor patients using standard filtered back projection and adaptive statistical iterative reconstruction

    International Nuclear Information System (INIS)

    Böning, G.; Schäfer, M.; Grupp, U.; Kaul, D.; Kahn, J.; Pavel, M.; Maurer, M.; Denecke, T.; Hamm, B.; Streitparth, F.

    2015-01-01

    Highlights: • Iterative reconstruction (IR) in staging CT provides equal objective image quality compared to filtered back projection (FBP). • IR delivers excellent subjective quality and reduces effective dose compared to FBP. • In patients with neuroendocrine tumor (NET) or may other hypervascular abdominal tumors IR can be used without scarifying diagnostic confidence. - Abstract: Objective: To investigate whether dose reduction via adaptive statistical iterative reconstruction (ASIR) affects image quality and diagnostic accuracy in neuroendocrine tumor (NET) staging. Methods: A total of 28 NET patients were enrolled in the study. Inclusion criteria were histologically proven NET and visible tumor in abdominal computed tomography (CT). In an intraindividual study design, the patients underwent a baseline CT (filtered back projection, FBP) and follow-up CT (ASIR 40%) using matched scan parameters. Image quality was assessed subjectively using a 5-grade scoring system and objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs). Applied volume computed tomography dose index (CTDI vol ) of each scan was taken from the dose report. Results: ASIR 40% significantly reduced CTDI vol (10.17 ± 3.06 mGy [FBP], 6.34 ± 2.25 mGy [ASIR] (p < 0.001) by 37.6% and significantly increased CNRs (complete tumor-to-liver, 2.76 ± 1.87 [FBP], 3.2 ± 2.32 [ASIR]) (p < 0.05) (complete tumor-to-muscle, 2.74 ± 2.67 [FBP], 4.31 ± 4.61 [ASIR]) (p < 0.05) compared to FBP. Subjective scoring revealed no significant changes for diagnostic confidence (5.0 ± 0 [FBP], 5.0 ± 0 [ASIR]), visibility of suspicious lesion (4.8 ± 0.5 [FBP], 4.8 ± 0.5 [ASIR]) and artifacts (5.0 ± 0 [FBP], 5.0 ± 0 [ASIR]). ASIR 40% significantly decreased scores for noise (4.3 ± 0.6 [FBP], 4.0 ± 0.8 [ASIR]) (p < 0.05), contrast (4.4 ± 0.6 [FBP], 4.1 ± 0.8 [ASIR]) (p < 0.001) and visibility of small structures (4.5 ± 0.7 [FBP], 4.3 ± 0.8 [ASIR]) (p < 0

  20. Comparison of applied dose and image quality in staging CT of neuroendocrine tumor patients using standard filtered back projection and adaptive statistical iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Böning, G., E-mail: georg.boening@charite.de [Department of Radiology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany); Schäfer, M.; Grupp, U. [Department of Radiology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany); Kaul, D. [Department of Radiation Oncology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany); Kahn, J. [Department of Radiology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany); Pavel, M. [Department of Gastroenterology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany); Maurer, M.; Denecke, T.; Hamm, B.; Streitparth, F. [Department of Radiology, Charité, Humboldt-University Medical School, Charitéplatz 1, 10117 Berlin (Germany)

    2015-08-15

    Highlights: • Iterative reconstruction (IR) in staging CT provides equal objective image quality compared to filtered back projection (FBP). • IR delivers excellent subjective quality and reduces effective dose compared to FBP. • In patients with neuroendocrine tumor (NET) or may other hypervascular abdominal tumors IR can be used without scarifying diagnostic confidence. - Abstract: Objective: To investigate whether dose reduction via adaptive statistical iterative reconstruction (ASIR) affects image quality and diagnostic accuracy in neuroendocrine tumor (NET) staging. Methods: A total of 28 NET patients were enrolled in the study. Inclusion criteria were histologically proven NET and visible tumor in abdominal computed tomography (CT). In an intraindividual study design, the patients underwent a baseline CT (filtered back projection, FBP) and follow-up CT (ASIR 40%) using matched scan parameters. Image quality was assessed subjectively using a 5-grade scoring system and objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs). Applied volume computed tomography dose index (CTDI{sub vol}) of each scan was taken from the dose report. Results: ASIR 40% significantly reduced CTDI{sub vol} (10.17 ± 3.06 mGy [FBP], 6.34 ± 2.25 mGy [ASIR] (p < 0.001) by 37.6% and significantly increased CNRs (complete tumor-to-liver, 2.76 ± 1.87 [FBP], 3.2 ± 2.32 [ASIR]) (p < 0.05) (complete tumor-to-muscle, 2.74 ± 2.67 [FBP], 4.31 ± 4.61 [ASIR]) (p < 0.05) compared to FBP. Subjective scoring revealed no significant changes for diagnostic confidence (5.0 ± 0 [FBP], 5.0 ± 0 [ASIR]), visibility of suspicious lesion (4.8 ± 0.5 [FBP], 4.8 ± 0.5 [ASIR]) and artifacts (5.0 ± 0 [FBP], 5.0 ± 0 [ASIR]). ASIR 40% significantly decreased scores for noise (4.3 ± 0.6 [FBP], 4.0 ± 0.8 [ASIR]) (p < 0.05), contrast (4.4 ± 0.6 [FBP], 4.1 ± 0.8 [ASIR]) (p < 0.001) and visibility of small structures (4.5 ± 0.7 [FBP], 4.3 ± 0.8 [ASIR]) (p < 0

  1. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    International Nuclear Information System (INIS)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U.

    2011-01-01

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  2. CT findings of parotid gland tumors: benign versus malignant tumors

    International Nuclear Information System (INIS)

    Lee, Moon Ok; Han, Chun Hwan; Kim, Mie Young; Yi, Jeong Geun; Park, Kyung Joo; Lee, Joo Hyuk; Bae, Sang Hoon; Kim, Jeung Sook

    1994-01-01

    The purpose of this study is to evaluate the characteristics of parotid gland tumors to help in the differentiation between benign and malignant lesions. The CT findings of 22 patients with surgically proven parotid gland tumors were reviewed. Analysis was focused on the density and margin characteristics of the tumors, and the relationship between the tumor and surrounding structures. Those tumors were pleomorphic adenoma (n = 8), Warthin's tumor (n = 5), basal cell adenoma (n = 1), lipoma (n = 1), dermoid cyst (n = 1), adenoid cystic carcinoma (n = 2), mucoepidermoid carcinoma (n 1), epidermoid carcinoma (n = 1), and carcinoma in pleomorphic adenoma (n 1). Most of benign and malignant tumors were heterogeneous in density on contrast enhanced CT scans. In 5 of 6 malignant cases, the tumors had irregular or ill-defined margin and a tendancy to involve or cross the superficial layer of deep cervical fascia with obliteration of subcutaneous fat. Two malignant tumors invaded surrounding structures. Although the heterogeneous density of tumor is not a specific finding for malignancy at CT, following findings, such as, irregular or blurred margin of the lesion, the involvement of fascial plane, and the infiltration of surrounding structures may suggest the possibility of malignant parotid tumor

  3. Malignant gastroduodenal stromal tumor imaging diagnosis

    International Nuclear Information System (INIS)

    Guo Qiang; Wen Feng; Zhao Zhenguo

    2010-01-01

    Objective: To assess the imaging features of malignant gastroduodenal stromal tumor (mGDST)as an aid to its diagnosis. Methods: The unenhanced and multi-phasic contrast-enhanced CT scans of 24 patients with pathologically proven mGDST and air-contrast upper gastrointestinal studies(15 patients) were reviewed by two radiologists. The tumor location, size, contour, margin, growth type, contrast enhancement pattern and presence of ulcer were recorded. Results: The mGDST was located in the gastric fundus (15), gastric body(3), pylorus(2) and duodenum(4). The pathological types were submucosal(9), intramuscular(9) and subserosal(6). CT findings of mGDST included lobular shape(17), tumor size>5cm(14), central necrosis(15), large and deep ulcer(6), heterogeneous contrast enhancement(1), metastasis(1). The diagnostic accuracy of air-contrast upper gastrointestinal studies and CT for location of mGDST was 93.3% and 100% respectively, for malignant features was both 75.0%. Conclusion: Most mGDST have some characteristic appearances including large tumor size greater than 5 cm, lobular shape, central necrosis, large and deep ulcer, heterogeneous contrast enhancement and metastasis. Lymph node enlargement was uncommon. The diagnostic accuracy can be improved by CT scan combined with upper gastrointestinal barium examination. (authors)

  4. Dynamic-thresholding level set: a novel computer-aided volumetry method for liver tumors in hepatic CT images

    Science.gov (United States)

    Cai, Wenli; Yoshida, Hiroyuki; Harris, Gordon J.

    2007-03-01

    Measurement of the volume of focal liver tumors, called liver tumor volumetry, is indispensable for assessing the growth of tumors and for monitoring the response of tumors to oncology treatments. Traditional edge models, such as the maximum gradient and zero-crossing methods, often fail to detect the accurate boundary of a fuzzy object such as a liver tumor. As a result, the computerized volumetry based on these edge models tends to differ from manual segmentation results performed by physicians. In this study, we developed a novel computerized volumetry method for fuzzy objects, called dynamic-thresholding level set (DT level set). An optimal threshold value computed from a histogram tends to shift, relative to the theoretical threshold value obtained from a normal distribution model, toward a smaller region in the histogram. We thus designed a mobile shell structure, called a propagating shell, which is a thick region encompassing the level set front. The optimal threshold calculated from the histogram of the shell drives the level set front toward the boundary of a liver tumor. When the volume ratio between the object and the background in the shell approaches one, the optimal threshold value best fits the theoretical threshold value and the shell stops propagating. Application of the DT level set to 26 hepatic CT cases with 63 biopsy-confirmed hepatocellular carcinomas (HCCs) and metastases showed that the computer measured volumes were highly correlated with those of tumors measured manually by physicians. Our preliminary results showed that DT level set was effective and accurate in estimating the volumes of liver tumors detected in hepatic CT images.

  5. Holographic observation of magnetic resonance image CT of intracranial tumors

    International Nuclear Information System (INIS)

    Iwata, Kinjiro; Watanabe, Saburo; Yuasa, Hiromi; Yamada, Takahisa; Hoshino, Daisaku; Suzuki, Masane; Saito, Takayuki.

    1987-01-01

    In 1975, we developed a new method of 3-dimensional observation of CT pictures using Gabor's holography principle. In this study, we are reporting our experience with the multi-tomogram holography using magnetic resonance image CT in order to reconstruct 3-dimensional viewing of the central nervous system and intracranial lesions. (J.P.N.)

  6. CT-criteria of orbital hemangiomas and their importance in differential diagnosis of intraconal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Unsoeld, R; Hoyt, W F [California Univ., San Francisco (USA). Dept. of Neurosurgery; California Univ., San Francisco (USA). Dept. of Neurology and Opthalmology; California Univ., San Francisco (USA). Dept. of Neuroradiology)

    1979-12-01

    CT-Scans of 29 histologically proven cavernous hemangiomas were evaluated with respect to their location, shape, delineation from surrounding tissue, contrast-enhancement, and secondary changes of the bony orbit. Whenever a round or oval tumor, located in the outer upper muscle cone, sharply delineated from surrounding tissue, unattached to optic nerve and ocular muscles, spares a small triangular space in the orbital apex, it is in all probability a cavernous hemangioma. Evaluation of the tumors shape and its separation from surrounding tissues requires imaging in multiple sections in two planes oriented, if possible, at right angles. Changes in position of the optic nerve and eye muscles in different directions of gaze demonstrated by CT rule out significant tumor-attachments. The portion of the intraconal space least affected by optic nerve shifts and muscle contractions during eye movements, as demonstrated by CT, is the upper outer quadrant, the site preferred by the mobile tumor. Tumors which cannot be differentiated from cavernous hemangiomas by CT-criteria are rare usually benign. Reports of rare examples of well delineated or encapsulated malignant intraconal lesions indicate the possibility - however remote - of mistaking a malignant tumor for a cavernous hemangioma by CT.

  7. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  8. Primary hyperparathyroidism, adrenal tumors and neuroendocrine tumors of the pancreas - clinical diagnosis and imaging requirements

    International Nuclear Information System (INIS)

    Auernhammer, C.J.; Engelhardt, D.; Goeke, B.

    2003-01-01

    Diseases of the parathyroids, the adrenals and of neuroendocrine tumors of the pancreas are primarily diagnosed by clinical and endocrinological evaluation.The requirements concerning various imaging techniques and their relative importance in localization strategies of the different tumors are complex. Current literature search, using PubMed. Evaluation of primary hyperparathyroidism requires bone densitometry by DXA and search for nephrolithiasis by ultrasound or native CT examination.While ultrasound of the thyroid and parathyroids seems useful before any parathyroid surgery,more extensive preoperative localization strategies (sestamibi scintigraphy, MRI) should be restricted to minimal invasive parathyroid surgery or re-operations.For adrenal tumors CT and MRI are of similar diagnostic value. Imaging of pheochromocytomas should be completed by MIBG scintigraphy. Each adrenal incidentaloma requires an endocrinological work-up.A fine-needle aspiration or core needle biopsy of an adrenal tumor is rarely indicated.Before adrenal biopsy a pheochromocytoma has to be excluded.Successful localization strategies for neuroendocrine tumors of the pancreas include somatostatin receptor scintigraphy, endoscopic ultrasound and MRI.Discussion Specific localization strategies have been established for the aforementioned tumors.The continuous progress of different imaging techniques requires a regular reevaluation of these localization strategies. (orig.) [de

  9. Detection and preoperative staging of carcinoma of the cervix: Comparison between MR imaging and CT

    International Nuclear Information System (INIS)

    Mayr, B.; Schmidt, H.; Baieri, P.; Scheidel, P.; Meier, W.; Schramm, T.

    1986-01-01

    Twenty-four patients with carcinoma of the cervix were examined preoperatively by MR imaging and CT. In all patients histopathologic confirmation was available for specimens obtained either by radical hysterectomy or at staging laparotomy. MR imaging was equivalent to contrast CT in the detection and evaluation of tumor extension in the cervix. Tumor extension to the parametria and pelvic wall was difficult to evaluate on both modalities, as neither had a higher accuracy than pelvic examination conducted under anesthesia. Nodal staging was nearly equivalent on MR imaging and CT. In the detection and staging of carcinoma of the cervix, MR imaged proved to be as good as CT with contrast agent enhancement

  10. Assessment of tumors of the lung apex by imaging techniques

    International Nuclear Information System (INIS)

    Rueda, J.; Serrano, F.; Pain, M.I.; Rodriguez, F.

    1996-01-01

    The purpose of this study was to analyze the value of MR in the preoperative staging of tumors of the lung apex and detection of local invasion of adjacent structures to determine its influence on the therapeutic approach. We obtained plain X-ray images in two planes, as well as CT and Mr images, in 12 patients with Pan coast tumor in whom there was surgical (n=8) or clinical (n=4) evidence of invasion. The objective was to assess local infiltration of brain stem and chest wall soft tissue, enveloping of the subclavian artery, substantial involvement of the brachial plexus and destruction of the vertebral body. In our series, MR was superior to the other imaging techniques in predicting the involvement of the structures surrounding the tumor. In conclusion, MR should be performed in a patient diagnosed by plain radiography as having an apical tumors to assess local tumor extension, while CT should be done to detect mediastinal lymph node involvement and distant metastases. 19 refs

  11. Comparison of manual vs. automated multimodality (CT-MRI) image registration for brain tumors

    International Nuclear Information System (INIS)

    Sarkar, Abhirup; Santiago, Roberto J.; Smith, Ryan; Kassaee, Alireza

    2005-01-01

    Computed tomgoraphy-magnetic resonance imaging (CT-MRI) registrations are routinely used for target-volume delineation of brain tumors. We clinically use 2 software packages based on manual operation and 1 automated package with 2 different algorithms: chamfer matching using bony structures, and mutual information using intensity patterns. In all registration algorithms, a minimum of 3 pairs of identical anatomical and preferably noncoplanar landmarks is used on each of the 2 image sets. In manual registration, the program registers these points and links the image sets using a 3-dimensional (3D) transformation. In automated registration, the 3 landmarks are used as an initial starting point and further processing is done to complete the registration. Using our registration packages, registration of CT and MRI was performed on 10 patients. We scored the results of each registration set based on the amount of time spent, the accuracy reported by the software, and a final evaluation. We evaluated each software program by measuring the residual error between 'matched' points on the right and left globes and the posterior fossa for fused image slices. In general, manual registration showed higher misalignment between corresponding points compared to automated registration using intensity matching. This error had no directional dependence and was, most of the time, larger for a larger structure in both registration techniques. Automated algorithm based on intensity matching also gave the best results in terms of registration accuracy, irrespective of whether or not the initial landmarks were chosen carefully, when compared to that done using bone matching algorithm. Intensity-matching algorithm required the least amount of user-time and provided better accuracy

  12. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  13. CT and MR images of pleomorphic adenoma in major and minor salivary glands

    International Nuclear Information System (INIS)

    Kakimoto, Naoya; Gamoh, Shoko; Tamaki, Junko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei

    2009-01-01

    Purpose: To investigate the CT and MR imaging features of pleomorphic adenoma in the head and neck area. Materials and methods: Our materials of this study consisted of 50 pleomorphic adenomas from 50 patients which were all histopathologically diagnosed. The CT and MR images were retrospectively evaluated. The following features were evaluated: the detectability of the lesion, the tumor margin, the border of the lesion, the aspect of the lesion, the contrast between the lesion and surrounding tissue, the signal intensity of the lesion, the enhancement of contrast medium, the aspect of the lesion after the injection of contrast medium, the detectability of the capsule, and the detectability of bone resorption of the lesion. Results: The tumor detectabilities were 77% on axial plain CT images and 90% on axial CE CT images, respectively. On CT images, pleomorphic adenoma tended to show a well-defined margin, a smooth border, an inhomogeneous aspect, a low or high contrast, and intermediate or high signal intensity. After contrast medium administration, pleomorphic adenoma tended to show a slightly high enhancement and either an inhomogeneous or a periphery enhancement on the CE CT images. The capsule could be hardly detected on CT images. The tumor detectabilities were 86% on axial T1-weighted MR images, 88% on axial T2-weighted MR images, and 85% on axial CE T1-weighted MR images, respectively. On MR images, pleomorphic adenomas tended to show well-defined margin, a lobulate border, an inhomogeneous aspect, a high contrast, and intermediate or high signal intensity. After contrast medium administration, pleomorphic adenoma tended to show a high enhancement and either an inhomogeneous or a periphery enhancement on MR images. The capsule could be detected in many cases on MR images. Conclusions: It was possible to detect the capsule in pleomorphic adenoma using MR images. The pleomorphic adenomas in head and neck area should be evaluated with MR images.

  14. Impact of tumor attachment to the pleura measured by a pretreatment CT image on outcome of stage I NSCLC treated with stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Yamamoto, Takaya; Kadoya, Noriyuki; Shirata, Yuko; Koto, Masashi; Sato, Kiyokazu; Matsushita, Haruo; Sugawara, Toshiyuki; Umezawa, Rei; Kubozono, Masaki; Ishikawa, Yojiro; Kozumi, Maiko; Takahashi, Noriyoshi; Ito, Kengo; Katagiri, Yu; Takeda, Ken; Jingu, Keiichi

    2015-01-01

    Pleural invasion status is known to be a predictor of survival after pulmonary resection for non-small cell lung cancer. Our goal was to determine whether the length of tumor attachment to the pleura on a pretreatment CT image has prognostic value as an alternative to pleural invasion status for stage I non-small cell lung cancer treated with stereotactic body radiotherapy (SBRT). A total of 90 tumors in 87 patients (males: 68, females: 19) who received SBRT between March 2005 and September 2011 in our institution were reviewed. The median age of the patients was 78 years (range, 48-90 years). The median tumor diameter was 2.2 cm (range, 0.9-4.2 cm). The prescribed dose was typically 48 Gy in 4 fractions, 60 Gy in 8 fractions or 60 Gy in 15 fractions to the isocenter with 6 MV X-ray using 4 non-coplanar and 3 coplanar static beams. The lengths of attachment were measured using pretreatment CT images at the lung window. Cumulative incidence rates were calculated using Kaplan-Meier curves, and univariate and multivariate analyses for in-field tumor control, locoregional control (LRC), freedom from distant metastasis and freedom from progression (FFP) were performed using a Cox proportional hazards model. Of the 90 tumors, 42 tumors were attached to the pleura (median, 14.7 mm; range, 4.3-36.0 mm), 21 tumors had pleural indentation and 27 tumors had no attachment. The median follow-up period for survivors was 46.1 months. The 3-year in-field control, LRC, FFP and overall survival rates were 91.2%, 75.3%, 63.8% and 68.6%, respectively. SBRT dose and tumor diameter were independently significant predictors of in-field control (p = 0.02 and p = 0.04, respectively). Broad attachment to the pleura, the length being more than 14.7 mm, was a negative independent predictor of LRC and FFP (p = 0.02 and p = 0.01, respectively). Pleural attachment status on a pretreatment CT image might be an important predictor of LRC and FFP

  15. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  16. SU-F-J-57: Effectiveness of Daily CT-Based Three-Dimensional Image Guided and Adaptive Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, S [University of Tsukuba, Tsukuba, Ibaraki (Japan); National Cancer Center, Kashiwa, Chiba (Japan); Tachibana, H; Hotta, K; Baba, H; Kohno, R; Akimoto, T [National Cancer Center, Kashiwa, Chiba (Japan); Nakamura, N [National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Miyakawa, S; Kurosawa, T [Komazawa University, Setagaya, Tokyo (Japan)

    2016-06-15

    Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilion LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported

  17. First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna; Hertz, Hans M. [Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 10691 Stockholm (Sweden); Westermark, Ulrica K.; Arsenian Henriksson, Marie [Department of Microbiology, Tumor and Cell Biology (MTC), Karolinska Institutet, 17177 Stockholm (Sweden)

    2013-02-15

    Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

  18. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  19. Digital tumor fluoroscopy (DTF)--a new direct imaging system in the therapy planning for brain tumors.

    Science.gov (United States)

    Herbst, M; Fröder, M

    1990-01-01

    Digital Tumor Fluoroscopy is an expanded x-ray video chain optimized to iodine contrast with an extended Gy scale up to 64000 Gy values. Series of pictures are taken before and after injection of contrast medium. With the most recent unit, up to ten images can be taken and stored. The microprogrammable processor allows the subtraction of images recorded at any moment of the examination. Dynamic views of the distribution of contrast medium in the intravasal and extravasal spaces of brain and tumor tissue are gained by the subtraction of stored images. Tumors can be differentiated by studying the storage and drainage behavior of the contrast medium during the period of examination. Meningiomas store contrast medium very intensively during the whole time of investigation, whereas astrocytomas grade 2-3 pick it up less strongly at the beginning and release it within 2 min. Glioblastomas show a massive but delayed accumulation of contrast medium and a decreased flow-off-rate. In comparison with radiography and MR-imaging the most important advantage of Digital Tumor Fluoroscopy is that direct information on tumor localization is gained in relation to the skull-cap. This enables the radiotherapist to mark the treatment field directly on the skull. Therefore it is no longer necessary to calculate the tumor volume from several CT scans for localization. In radiotherapy Digital Tumor Fluoroscopy a unit combined with a simulator can replace CT planning. This would help overcome the disadvantages arising from the lack of a collimating system, and the inaccuracies which result from completely different geometric relationships between a CT unit and a therapy machine.

  20. Importance of PET/CT for imaging of colorectal cancer

    International Nuclear Information System (INIS)

    Meinel, F.G.; Schramm, N.; Graser, A.; Reiser, M.F.; Rist, C.; Haug, A.R.

    2012-01-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has emerged as a very useful imaging modality in the management of colorectal carcinoma. Data from the literature regarding the role of PET/CT in the initial diagnosis, staging, radiotherapy planning, response monitoring and surveillance of colorectal carcinoma is presented. Future directions and economic aspects are discussed. Computed tomography (CT), magnetic resonance imaging (MRI) and FDG-PET for colorectal cancer and endorectal ultrasound for rectal cancer. Combined FDG-PET/CT. While other imaging modalities allow superior visualization of the extent and invasion depth of the primary tumor, PET/CT is most sensitive for the detection of distant metastases of colorectal cancer. We recommend a targeted use of PET/CT in cases of unclear M staging, prior to metastasectomy and in suspected cases of residual or recurrent colorectal carcinoma with equivocal conventional imaging. The role of PET/CT in radiotherapy planning and response monitoring needs to be determined. Currently there is no evidence to support the routine use of PET/CT for colorectal screening, staging or surveillance. To optimally exploit the synergy between morphologic and functional information, FDG-PET should generally be performed as an integrated FDG-PET/CT with a contrast-enhanced CT component in colorectal carcinoma. (orig.) [de

  1. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H

    2015-01-01

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology

  2. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.

  3. Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Shinichi; Shirato, Hiroki; Kagei, Kenji; Nishioka, Takeshi; Bo Xo; Dosaka-Akita, Hirotoshi; Hashimoto, Seiko; Aoyama, Hidefumi; Tsuchiya, Kazuhiko; Miyasaka, Kazuo

    2000-01-01

    Purpose: Three-dimensional (3D) treatment planning has often been performed while patients breathe freely, under the assumption that the computed tomography (CT) images represent the average position of the tumor. We investigated the impact of respiratory movement on the free-breathing CT images of small lung tumors using sequential CT scanning at the same table position. Methods: Using a preparatory free-breathing CT scan, the patient's couch was fixed at the position where each tumor showed its maximum diameter on image. For 16 tumors, over 20 sequential CT images were taken every 2 s, with a 1-s acquisition time occurring during free breathing. For each tumor, the distance between the surface of the CT table and the posterior border of the tumor was measured to determine whether the edge of the tumor was sufficiently included in the planning target volume (PTV) during normal breathing. Results: In the sequential CT scanning, the tumor itself was not visible in the examination slice in 21% (75/357) of cases. There were statistically significant differences between lower lobe tumors (39.4%, 71/180) and upper lobe tumors (0%, 0/89) (p < 0.01) and between lower lobe tumors and middle lobe tumor (8.9%, 4/45) (p < 0.01) in the incidence of the disappearance of the tumor from the image. The mean difference between the maximum and minimum distances between the surface of the CT table and the posterior border of the tumor was 6.4 mm (range 2.1-24.4). Conclusion: Three-dimensional treatment planning for lung carcinoma would significantly underdose many lesions, especially those in the lower lobe. The excess 'safety margin' might call into question any additional benefit of 3D treatment. More work is required to determine how to control respiratory movement

  4. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro

    2014-01-01

    Osteoma is a benign bone-forming tumor that usually arises in the craniofacial bones and rarely in the long bones. Clavicular involvement is extremely rare. We report a 51-year-old woman with osteoma of the left clavicle. Radiograph of the left shoulder showed a well-defined lobulated blastic mass in the proximal and mid-portion of the left clavicle. Bone scintigraphy was performed 4 hours after an intravenous injection of Tc-99m hydroxymethylene diphosphonate (HMDP). Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography / computed tomography (SPECT/CT) images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis

  5. CT imaging features of anaplastic thyroid carcinoma

    International Nuclear Information System (INIS)

    Shi Zhenshan; You Ruixiong; Cao Dairong; Li Yueming; Zhuang Qian

    2013-01-01

    Objective: To investigate the CT characteristics of anaplastic thyroid carcinoma and evaluate the diagnostic value of CT in this disease. Methods: The CT findings of 10 patients with pathologically proved anaplastic thyroid carcinoma were retrospectively reviewed. The patients included 7 females and 3 males. Their age ranged from 25.0 to 78 years with median of 61 years. Multi-slices plain and post contrast CT scans were performed in all patients. Results: Unilateral thyroid was involved in 6 patients. Unilateral thyroid and thyroid isthmus were both involved in 2 patients due to big size. Bilateral thyroid were involved in 2 patients. The maximum diameter of anaplastic thyroid carcinoma ranged from 2.9-12.8 cm with mean of (4.5 ± 1.4) cm. All lesions demonstrated unclear margins and envelope invasion. The densities of all lesions were heterogeneous and obvious necrosis areas were noted on precontrast images. Seven lesions showed varied calcifications, and coarse granular calcifications were found in 5 lesions among them. All lesions showed remarkable heterogenous enhancement on post-contrast CT. The CT value of solid portion of the tumor increased 40 HU after contrast media administration. The ratios of CT value which comparing of the tumor with contralateral sternocleidomastoid muscle were 0.69-0.82 (0.76 ± 0.18) and 1.25-1.41 (1.33 ± 0.28) on pre and post CT, respectively. Enlarged cervical lymph nodes were found in 6 cases (60.0%). It showed obvious homogeneous enhancement or irregular ring-like enhancement on post-contrast images and dot calcifications were seen in 1 case. Conclusions: Relative larger single thyroid masses with coarse granular calcifications, necrosis,envelope invasion, remarkable heterogeneous enhancing and enlarged lymph nodes on CT are suggestive of anaplastic thyroid carcinoma. (authors)

  6. Semi-automatic delineation using weighted CT-MRI registered images for radiotherapy of nasopharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fitton, I. [European Georges Pompidou Hospital, Department of Radiology, 20 rue Leblanc, 75015, Paris (France); Cornelissen, S. A. P. [Image Sciences Institute, UMC, Department of Radiology, P.O. Box 85500, 3508 GA Utrecht (Netherlands); Duppen, J. C.; Rasch, C. R. N.; Herk, M. van [The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Radiotherapy, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Steenbakkers, R. J. H. M. [University Medical Center Groningen, Department of Radiation Oncology, Hanzeplein 1, 9713 GZ Groningen (Netherlands); Peeters, S. T. H. [UZ Gasthuisberg, Herestraat 49, 3000 Leuven, Belgique (Belgium); Hoebers, F. J. P. [Maastricht University Medical Center, Department of Radiation Oncology (MAASTRO clinic), GROW School for Oncology and Development Biology Maastricht, 6229 ET Maastricht (Netherlands); Kaanders, J. H. A. M. [UMC St-Radboud, Department of Radiotherapy, Geert Grooteplein 32, 6525 GA Nijmegen (Netherlands); Nowak, P. J. C. M. [ERASMUS University Medical Center, Department of Radiation Oncology,Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2011-08-15

    Purpose: To develop a delineation tool that refines physician-drawn contours of the gross tumor volume (GTV) in nasopharynx cancer, using combined pixel value information from x-ray computed tomography (CT) and magnetic resonance imaging (MRI) during delineation. Methods: Operator-guided delineation assisted by a so-called ''snake'' algorithm was applied on weighted CT-MRI registered images. The physician delineates a rough tumor contour that is continuously adjusted by the snake algorithm using the underlying image characteristics. The algorithm was evaluated on five nasopharyngeal cancer patients. Different linear weightings CT and MRI were tested as input for the snake algorithm and compared according to contrast and tumor to noise ratio (TNR). The semi-automatic delineation was compared with manual contouring by seven experienced radiation oncologists. Results: A good compromise for TNR and contrast was obtained by weighing CT twice as strong as MRI. The new algorithm did not notably reduce interobserver variability, it did however, reduce the average delineation time by 6 min per case. Conclusions: The authors developed a user-driven tool for delineation and correction based a snake algorithm and registered weighted CT image and MRI. The algorithm adds morphological information from CT during the delineation on MRI and accelerates the delineation task.

  7. Lung metastases detection in CT images using 3D template matching

    International Nuclear Information System (INIS)

    Wang, Peng; DeNunzio, Andrea; Okunieff, Paul; O'Dell, Walter G.

    2007-01-01

    The aim of this study is to demonstrate a novel, fully automatic computer detection method applicable to metastatic tumors to the lung with a diameter of 4-20 mm in high-risk patients using typical computed tomography (CT) scans of the chest. Three-dimensional (3D) spherical tumor appearance models (templates) of various sizes were created to match representative CT imaging parameters and to incorporate partial volume effects. Taking into account the variability in the location of CT sampling planes cut through the spherical models, three offsetting template models were created for each appearance model size. Lung volumes were automatically extracted from computed tomography images and the correlation coefficients between the subregions around each voxel in the lung volume and the set of appearance models were calculated using a fast frequency domain algorithm. To determine optimal parameters for the templates, simulated tumors of varying sizes and eccentricities were generated and superposed onto a representative human chest image dataset. The method was applied to real image sets from 12 patients with known metastatic disease to the lung. A total of 752 slices and 47 identifiable tumors were studied. Spherical templates of three sizes (6, 8, and 10 mm in diameter) were used on the patient image sets; all 47 true tumors were detected with the inclusion of only 21 false positives. This study demonstrates that an automatic and straightforward 3D template-matching method, without any complex training or postprocessing, can be used to detect small lung metastases quickly and reliably in the clinical setting

  8. Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue

    International Nuclear Information System (INIS)

    Brock, Kristy K.; Dawson, Laura A.; Sharpe, Michael B.; Moseley, Douglas J.; Jaffray, David A.

    2006-01-01

    Purpose: To investigate the feasibility of a biomechanical-based deformable image registration technique for the integration of multimodality imaging, image guided treatment, and response monitoring. Methods and Materials: A multiorgan deformable image registration technique based on finite element modeling (FEM) and surface projection alignment of selected regions of interest with biomechanical material and interface models has been developed. FEM also provides an inherent method for direct tracking specified regions through treatment and follow-up. Results: The technique was demonstrated on 5 liver cancer patients. Differences of up to 1 cm of motion were seen between the diaphragm and the tumor center of mass after deformable image registration of exhale and inhale CT scans. Spatial differences of 5 mm or more were observed for up to 86% of the surface of the defined tumor after deformable image registration of the computed tomography (CT) and magnetic resonance images. Up to 6.8 mm of motion was observed for the tumor after deformable image registration of the CT and cone-beam CT scan after rigid registration of the liver. Deformable registration of the CT to the follow-up CT allowed a more accurate assessment of tumor response. Conclusions: This biomechanical-based deformable image registration technique incorporates classification, targeting, and monitoring of tumor and normal tissue using one methodology

  9. Maximum-intensity-projection CT angiography for evaluating head and neck tumors. Usefulness of helical CT and auto bone masking method

    International Nuclear Information System (INIS)

    Sakai, Osamu; Nakashima, Noriko; Ogawa, Chiaki; Shen, Yun; Takata, Yasunori; Azemoto, Shougo.

    1994-01-01

    Angiographic images of 10 adult patients with head and neck tumors were obtained by helical computed tomography (CT) using maximum intensity projection (MIP). In all cases, the vasculature of the head and neck region was directly demonstrated. In the head and neck, bone masking is a more important problem than in other regions. We developed an effective automatic bone masking method (ABM) using 2D/3D connectivity. Helical CT angiography with MIP and ABM provided accurate anatomic depiction, and was considered to be helpful in preoperative evaluation of head and neck tumors. (author)

  10. In-room CT techniques for image-guided radiation therapy

    International Nuclear Information System (INIS)

    Ma, C.-M. Charlie; Paskalev, Kamen M.S.

    2006-01-01

    Accurate patient setup and target localization are essential to advanced radiation therapy treatment. Significant improvement has been made recently with the development of image-guided radiation therapy, in which image guidance facilitates short treatment course and high dose per fraction radiotherapy, aiming at improving tumor control and quality of life. Many imaging modalities are being investigated, including x-ray computed tomography (CT), ultrasound imaging, positron emission tomography, magnetic resonant imaging, magnetic resonant spectroscopic imaging, and kV/MV imaging with flat panel detectors. These developments provide unique imaging techniques and methods for patient setup and target localization. Some of them are different; some are complementary. This paper reviews the currently available kV x-ray CT systems used in the radiation treatment room, with a focus on the CT-on-rails systems, which are diagnostic CT scanners moving on rails installed in the treatment room. We will describe the system hardware including configurations, specifications, operation principles, and functionality. We will review software development for image fusion, structure recognition, deformation correction, target localization, and alignment. Issues related to the clinical implementation of in-room CT techniques in routine procedures are discussed, including acceptance testing and quality assurance. Clinical applications of the in-room CT systems for patient setup, target localization, and adaptive therapy are also reviewed for advanced radiotherapy treatments

  11. Prognostic value of PET/CT in lung cancer. Study of survival and tumor metabolic characterization

    International Nuclear Information System (INIS)

    Ladron de Guevara, David; Fuentes Anibal; Farina, Ciro; Corral, Camilo; Pefaur, Raul

    2013-01-01

    PET/CT (Positron emission tomography/computed tomography) is a hybrid image modality widely used in oncology, for staging, therapy evaluation or follow up. Aim: To evaluate the prognostic value of PET/CT in lung cancer. Material and Methods: Retrospective review of PET/CT records, selecting 51 patients with a lung malignancy, mass or nodule referred for PET/CT between December 2008 and December 2010. All had pathological confirmation of malignancy and had not been treated previously. Age, gender, body mass index, radiological features of lung tumor and metastases, and lung tumor 18 F-fluoro-2-deoxy-d-glucose uptake using the SUV (Standardized uptake value) index were recorded. Survival was analyzed using Kaplan-Meier curves and a Cox proportional regression analysis. Results: Pathology confirmed the presence of lung cancer in 47 patients aged 30 to 88 years. Four patients (7.8%) had other type of tumors such as carcinoid or lymphoma. Fifty percent of lung cancer patients died during a mean observation lapse of 18 months (range: 2-34 months). Patients with metastases, local lymph node involvement, a lung tumor size ≥ 3 cm and high tumor uptake (SUVmax > 6) had significantly lower survival. Occurrence of metastases was the only independent prognostic factor in the Cox regression. A lung lesion with a SUVmax ≥ 12 was always associated to hilar/mediastinal lymph node involvement. Conclusions: PET/CT imaging gives important prognostic information in lung cancer patients

  12. Optimal CT scanning parameters for commonly used tumor ablation applicators

    International Nuclear Information System (INIS)

    Eltorai, Adam E.M.; Baird, Grayson L.; Monu, Nicholas; Wolf, Farrah; Seidler, Michael; Collins, Scott; Kim, Jeomsoon; Dupuy, Damian E.

    2017-01-01

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  13. Optimal CT scanning parameters for commonly used tumor ablation applicators

    Energy Technology Data Exchange (ETDEWEB)

    Eltorai, Adam E.M. [Warren Alpert Medical School of Brown University (United States); Baird, Grayson L. [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Lifespan Biostatistics Core (United States); Rhode Island Hospital (United States); Monu, Nicholas; Wolf, Farrah; Seidler, Michael [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States); Collins, Scott [Department of Diagnostic Imaging (United States); Rhode Island Hospital (United States); Kim, Jeomsoon [Department of Medical Physics (United States); Rhode Island Hospital (United States); Dupuy, Damian E., E-mail: ddupuy@comcast.net [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States)

    2017-04-15

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  14. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  15. Comprehensive imaging of tumor recurrence in breast cancer patients using whole-body MRI at 1.5 and 3 T compared to FDG-PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany)], E-mail: gerwin.schmidt@med.uni-muenchen.de; Baur-Melnyk, Andrea [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Haug, Alexander [Department of Nuclear Medicine, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Heinemann, Volker [Department of Internal Medicine III, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Bauerfeind, Ingo [Department of Obstetrics and Gynecology, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Reiser, Maximilian F. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Schoenberg, Stefan O. [Institute of Clinical Radiology University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg (Germany)

    2008-01-15

    Purpose: To compare the diagnostic accuracy for the detection of tumor recurrence in breast cancer patients using whole-body-MRI (WB-MRI) at 1.5 or 3 T compared to FDG-PET-CT. Materials and methods: Thirty-three female patients with breast cancer and suspicion of recurrence underwent FDG-PET-CT and WB-MRI. Coronal T1w-TSE- and STIR-sequences, HASTE-imaging of the lungs, contrast-enhanced T1w- and T2w-TSE-sequences of the liver, brain and abdomen were performed, using a WB-MRI-scanner at 1.5 (n = 23) or 3 T (n = 10). Presence of local recurrence, lymph node involvement and distant metastatic disease was assessed using clinical and radiological follow-up as a standard of reference. Results: Tumor recurrence was found in 20 of 33 patients. Overall 186 malignant foci were detected with WB-MRI and PET-CT. Both modalities revealed two recurrent tumors of the breast. PET-CT detected more lymph node metastases (n = 21) than WB-MRI (n = 16). WB-MRI was more precise in the detection of distant metastases (n = 154 versus n = 147). Sensitivity was 93% (172/186) and 91% (170/186) for WB-MRI and PET-CT, specificity was 86% (66/77) and 90% (69/77), respectively. Examination times for WB-MRI at 1.5 and 3 T were 51 and 43 min, respectively, examination time for PET-CT was 103 min. Conclusion: WB-MRI and PET-CT are useful for the detection of tumor recurrence in the follow-up of breast cancer. WB-MRI is highly sensitive to distant metastatic disease. PET-CT is more sensitive in detecting lymph node involvement. Tumor screening with WB-MRI is feasible at 1.5 and 3 T, scan time is further reduced at 3 T with identical resolution.

  16. Nuclear imaging of neuroendocrine tumors with unknown primary: why, when and how?

    Energy Technology Data Exchange (ETDEWEB)

    Santhanam, Prasanna; Chandramahanti, Sangeeta [Marshall University, Section of Endocrinology, Department of Internal Medicine, Joan C Edwards School of Medicine, Huntington, WV (United States); Kroiss, Alexander [Medical University Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Yu, Run [Cedars-Sinai Medical Center, Division of Endocrinology and Carcinoid and Neuroendocrine Tumor Center, Los Angeles, CA (United States); Ruszniewski, Philippe [Beaujon Hospital and Paris-Diderot University, Department of Gastroenterology-Pancreatology, Paris (France); Kumar, Rakesh [All India Institute of Medical Sciences, Diagnostic Nuclear Medicine Division, Department of Nuclear Medicine, New Delhi (India); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France)

    2015-03-13

    Neuroendocrine tumors (NETs) with unknown primary (CUP-NET) are associated with a poor prognosis (10-year survival 22 %), grade 1 and 2 NETs having a more favorable outcome than grade 3 (also called carcinoma). There is evidence that an effort should be made to localize the primary tumor even in the presence of metastasis because resection of the primary tumor(s) may improve disease-free and overall survival, and because the choice of chemotherapeutic agent depends on the location of the primary tumor. Localization of the tumors remains challenging and often relies on a combination of radiological, endoscopic and functional imaging. The functional imaging protocol for evaluation of these patients has historically relied on somatostatin receptor scintigraphy (SRS). However, the sensitivity and specificity of SRS may be unsatisfactory, especially for NETs of midgut origin. Newer PET radiotracers such as {sup 68}Ga-labeled somatostatin analogs ({sup 68}Ga-DOTA-SSTa) and {sup 18}F-DOPA have shown promise. In direct comparisons between {sup 68}Ga-DOTA-SSTa PET/CT and {sup 99m}Tc-HYNIC-octreotide/{sup 111}In-pentetreotide SPECT(/CT), {sup 68}Ga-DOTA-SSTa performed better than other techniques, giving a compelling reason for switching from SPECT/CT to PET/CT imaging. {sup 18}F-DOPA performs better than SRS and CT in well-differentiated NETs of the small intestine. For detecting pancreatic NETs, the high background uptake of {sup 18}F-DOPA by the normal exocrine pancreas can be somewhat overcome by pretreatment with carbidopa. We have suggested a protocol in which SRS is replaced by one of the two agents (preferably with {sup 68}Ga-DOTA-SSTa, alternatively {sup 18}F-DOPA) as first-line nuclear tracer for detection of CUP-NET in patients with well-differentiated NETs and {sup 18}F-FDG PET/CT may be an additional diagnostic test for poorly differentiated tumors and for prognostication. In the near future, it is expected that patients with CUP-NET will benefit from newly

  17. Nuclear imaging of neuroendocrine tumors with unknown primary: why, when and how?

    International Nuclear Information System (INIS)

    Santhanam, Prasanna; Chandramahanti, Sangeeta; Kroiss, Alexander; Yu, Run; Ruszniewski, Philippe; Kumar, Rakesh; Taieb, David

    2015-01-01

    Neuroendocrine tumors (NETs) with unknown primary (CUP-NET) are associated with a poor prognosis (10-year survival 22 %), grade 1 and 2 NETs having a more favorable outcome than grade 3 (also called carcinoma). There is evidence that an effort should be made to localize the primary tumor even in the presence of metastasis because resection of the primary tumor(s) may improve disease-free and overall survival, and because the choice of chemotherapeutic agent depends on the location of the primary tumor. Localization of the tumors remains challenging and often relies on a combination of radiological, endoscopic and functional imaging. The functional imaging protocol for evaluation of these patients has historically relied on somatostatin receptor scintigraphy (SRS). However, the sensitivity and specificity of SRS may be unsatisfactory, especially for NETs of midgut origin. Newer PET radiotracers such as 68 Ga-labeled somatostatin analogs ( 68 Ga-DOTA-SSTa) and 18 F-DOPA have shown promise. In direct comparisons between 68 Ga-DOTA-SSTa PET/CT and 99m Tc-HYNIC-octreotide/ 111 In-pentetreotide SPECT(/CT), 68 Ga-DOTA-SSTa performed better than other techniques, giving a compelling reason for switching from SPECT/CT to PET/CT imaging. 18 F-DOPA performs better than SRS and CT in well-differentiated NETs of the small intestine. For detecting pancreatic NETs, the high background uptake of 18 F-DOPA by the normal exocrine pancreas can be somewhat overcome by pretreatment with carbidopa. We have suggested a protocol in which SRS is replaced by one of the two agents (preferably with 68 Ga-DOTA-SSTa, alternatively 18 F-DOPA) as first-line nuclear tracer for detection of CUP-NET in patients with well-differentiated NETs and 18 F-FDG PET/CT may be an additional diagnostic test for poorly differentiated tumors and for prognostication. In the near future, it is expected that patients with CUP-NET will benefit from newly developed PET approaches (radiopharmaceuticals) and

  18. Imaging of tumor viability in lung cancer. Initial results using 23Na-MRI

    International Nuclear Information System (INIS)

    Henzler, T.; Apfaltrer, P.; Haneder, S.; Schoenberg, S.O.; Fink, C.; Konstandin, S.; Schad, L.; Schmid-Bindert, G.; Manegold, C.; Wenz, F.

    2012-01-01

    23 Na-MRI has been proposed as a potential imaging biomarker for the assessment of tumor viability and the evaluation of therapy response but has not yet been evaluated in patients with lung cancer. We aimed to assess the feasibility of 23 Na-MRI in patients with lung cancer. Three patients with stage IV adenocarcinoma of the lung were examined on a clinical 3 Tesla MRI system (Magnetom TimTrio, Siemens Healthcare, Erlangen, Germany). Feasibility of 23 Na-MRI images was proven by comparison and fusion of 23 Na-MRI with 1 H-MR, CT and FDG-PET-CT images. 23 Na signal intensities (SI) of tumor and cerebrospinal fluid (CSF) of the spinal canal were measured and the SI ratio in tumor and CSF was calculated. One chemonaive patient was examined before and after the initiation of combination therapy (Carboplatin, Gemcitabin, Cetuximab). All 23 Na-MRI examinations were successfully completed and were of diagnostic quality. Fusion of 23 Na-MRI images with 1 H-MRI, CT and FDG-PET-CT was feasible in all patients and showed differences in solid and necrotic tumor areas. The mean tumor SI and the tumor/CSF SI ratio were 13.3 ± 1.8 x 103 and 0.83 ± 0.14, respectively. In necrotic tumors, as suggested by central non-FDG-avid areas, the mean tumor SI and the tumor/CSF ratio were 19.4 x 103 and 1.10, respectively. 23 Na-MRI is feasible in patients with lung cancer and could provide valuable functional molecular information regarding tumor viability, and potentially treatment response. (orig.)

  19. Comparative evaluation of the porta hepatis/hepatoduodenal ligament with CT and MR imaging

    International Nuclear Information System (INIS)

    Silverman, P.M.; Feuerstein, I.M.; Zeman, R.K.; Jaffe, M.H.; Garra, B.S.

    1988-01-01

    CT and MR imaging were compared in a retrospective evaluation of 16 patients with abnormalities, predominantly neoplasms, of the porta hepatis/hepatoduodenal ligament. Masses on CT were of decreased density compared with that of liver and were seen in contrast to surrounding periportal fat. On MR images, T1-weighted images demonstrated findings similar to those of CT. T2-weighted images clearly depicted intrahepatic lesions but less distinctly depicted lesions surrounded by fat. Short inversion recovery (STIR) images better demonstrated tumor relative to fat. CT was better than all MR imaging sequences in one of 16 cases, whereas at least one MR imaging sequence was better than CT in six of 16. In nine cases, CT was equivalent to the best MR imaging sequence. In five of six cases where MR imaging was better than CT, STIR sequences were most favorable. In conclusion, MR imaging provided a valuable technique for assessing abnormalities of the porta hepatis/hepatoduodenal ligament

  20. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  1. Imaging of childhood inflammatory myofibroblastic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oguz, Berna; Ozcan, Hatice Nursun; Omay, Burak; Ozgen, Burce; Haliloglu, Mithat [Division of Pediatric Radiology, Hacettepe University Faculty of Medicine, Department of Radiology, Altindag / Sihhiye, Ankara (Turkey)

    2015-10-15

    Inflammatory myofibroblastic tumor is a rare benign neoplasm and most commonly involves the lung but occurs in extrapulmonary locations. To present imaging findings in inflammatory myofibroblastic tumors in children based on a single-centre experience. We retrospectively reviewed CT and MRI findings of children diagnosed with inflammatory myofibroblastic tumor in a single institution. We identified 15 children (range: 1-17 years) with inflammatory myofibroblastic tumor. The tumor was localized to the lung (n = 5), mediastinum (n = 3), trachea (n = 1), bronchus (n = 1), abdomen (n = 2) and orbit (n = 3). All the extraorbital tumors were solid masses with homogeneous or heterogeneous enhancement. Four lung tumors and one posterior mediastinal tumor contained calcification. Local recurrence following surgical removal occurred in two children with invasion of the esophagus and of the left atrium in one. Localized masses were seen in all children with orbital tumour. Two of these had episcleritis and perineuritis; one had episcleritis, tendonitis, perineuritis, myositis and dacryoadenitis. The locations and imaging features of inflammatory myofibroblastic tumors are variable. (orig.)

  2. Multimodal imaging in neurofibromatosis type 1-associated nerve sheath tumors

    International Nuclear Information System (INIS)

    Salamon, J.; Adam, G.; Mautner, V.F.; Derlin, T.

    2015-01-01

    Neurofibromatosis type 1 (NF1) is a neurogenetic disorder. Individuals with NF1 may develop a variety of benign and malignant tumors of which peripheral nerve sheath tumors represent the most frequent entity. Plexiform neurofibromas may demonstrate a locally destructive growth pattern, may cause severe symptoms and may undergo malignant transformation into malignant peripheral nerve sheath tumors (MPNSTs). Whole-body magnetic resonance imaging (MRI) represents the reference standard for detection of soft tissue tumors in NF1. It allows for identification of individuals with plexiform neurofibromas, for assessment of local tumor extent, and for evaluation of whole-body tumor burden on T2-weighted imaging. Multiparametric MRI may provide a comprehensive characterization of different tissue properties of peripheral nerve sheath tumors, and may identify parameters associated with malignant transformation. Due to the absence of any radiation exposure, whole-body MRI may be used for serial follow-up of individuals with plexiform neurofibromas. 18 F-fluorodeoxyglucose positron-emission-tomography (FDG PET/CT) allows a highly sensitive and specific detection of MPNST, and should be used in case of potential malignant transformation of a peripheral nerve sheath tumor. PET/CT provides a sensitive whole-body tumor staging. The use of contrast-enhanced CT for diagnosis of peripheral nerve sheath tumors is limited to special indications. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of peripheral nerve sheath tumors are required.

  3. A comparison of 111In- or 64Cu-DOTA-trastuzumab Fab fragments for imaging subcutaneous HER2-positive tumor xenografts in athymic mice using microSPECT/CT or microPET/CT

    Science.gov (United States)

    2011-01-01

    Background Our objective was to compare 111In- or 64Cu-DOTA-trastuzumab Fab fragments for imaging small or large s.c. tumor xenografts in athymic mice that display a wide range of human epidermal growth factor receptor-2 (HER2) expression using microSPECT/CT or microPET/CT. Methods Trastuzumab Fab were labeled with 111In or 64Cu by conjugation to 1,4,7,10-tetraazacyclododecane N, N', N'', N'''-tetraacetic acid (DOTA). The purity of 111In- and 64Cu-DOTA-trastuzumab Fab was measured by SDS-PAGE and HPLC. HER2 binding affinity was determined in saturation radioligand binding assays using SKBR-3 cells (1.3 × 106 HER2/cell). MicroSPECT/CT and microPET/CT were performed in athymic mice bearing s.c. BT-20 and MDA-MB-231 xenografts with low (0.5 to 1.6 × 105 receptors/cell), MDA-MB-361 tumors with intermediate (5.1 × 105 receptors/cell) or SKOV-3 xenografts with high HER2 expression (1.2 × 106 receptors/cell) at 24 h p.i. of 70 MBq (10 μg) of 111In-DOTA-trastuzumab Fab or 22 MBq (10 μg) of 64Cu-DOTA-trastuzumab Fab or irrelevant 111In- or 64Cu-DOTA-rituximab Fab. Tumor and normal tissue uptake were quantified in biodistribution studies. Results 111In- and 64Cu-DOTA-trastuzumab were > 98% radiochemically pure and bound HER2 with high affinity (Kd = 20.4 ± 2.5 nM and 40.8 ± 3.5 nM, respectively). MDA-MB-361 and SKOV-3 tumors were most clearly imaged using 111In- and 64Cu-DOTA-trastuzumab Fab. Significantly higher tumor/blood (T/B) ratios were found for 111In-DOTA-trastuzumab Fab than 111In-DOTA-rituximab Fab for BT-20, MDA-MB-231 and MDA-MB-361 xenografts, and there was a direct association between T/B ratios and HER2 expression. In contrast, tumor uptake of 64Cu-DOTA-trastuzumab Fab was significantly higher than 64Cu-DOTA-rituximab Fab in MDA-MB-361 tumors but no direct association with HER2 expression was found. Both 111In- and 64Cu-DOTA-trastuzumab Fab imaged small (5 to 10 mm) or larger (10 to 15 mm) MDA-MB-361 tumors. Higher blood, liver, and spleen

  4. Imaging tumors of the patella

    Energy Technology Data Exchange (ETDEWEB)

    Casadei, R., E-mail: roberto.casadei@ior.it [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Kreshak, J., E-mail: j.kreshak@yahoo.com [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy); Rinaldi, R. [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Rimondi, E., E-mail: eugenio.rimondi@ior.it [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Bianchi, G., E-mail: giuseppe.bianchi@ior.it [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Alberghini, M., E-mail: marco.alberghini@ior.it [Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy); Ruggieri, P. [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Vanel, D., E-mail: daniel.vanel@ior.it [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy)

    2013-12-01

    Background: Patellar tumors are rare; only a few series have been described in the literature and radiographic diagnosis can be challenging. We reviewed all patellar tumors at one institution and reviewed the literature. Materials and methods: In an evaluation of the database at one institution from 1916 to 2009, 23,000 bone tumors were found. Of these, 41 involved the patella. All had imaging studies and microscopic diagnostic confirmation. All medical records, imaging studies, and pathology were reviewed. Results: There were 15 females and 26 males, ranging from 8 to 68 years old (average 30). There were 30 benign tumors; eight giant cell tumors, eight chondroblastomas, seven osteoid osteomas, two aneurysmal bone cysts, two ganglions, one each of chondroma, exostosis, and hemangioma. There were 11 malignant tumors: five hemangioendotheliomas, three metastases, one lymphoma, one plasmacytoma, and one angiosarcoma. Conclusion: Patellar tumors are rare and usually benign. As the patella is an apophysis, the most frequent lesions are giant cell tumor in the adult and chondroblastoma in children. Osteoid osteomas were frequent in our series and easily diagnosed. Metastases are the most frequent malignant diagnoses in the literature; in our series malignant vascular tumors were more common. These lesions are often easily analyzed on radiographs. CT and MR define better the cortex, soft tissue extension, and fluid levels. This study presents the imaging patterns of the more common patellar tumors in order to help the radiologist when confronted with a lesion in this location.

  5. Analysis of the value of imaging in diagnosing pancreatic solid-pseudopapillary tumor

    International Nuclear Information System (INIS)

    Sun Canhui; Li Ziping; Meng Quanfei; Feng Shiting; Fan Miao; Peng Zhenpeng

    2007-01-01

    Objective: To describe the imaging features of solid-pseudopapillary tumor of the pancreas(SPTP) and evaluate the value of imaging in diagnosing SPTP. Methods: The imaging appearances in seven cases of SPTP confirmed by surgery and pathology were analyzed retrospectively. The un-enhanced and biphasic enhanced CT scanning were per- formed on all seven cases, including gastrointestinal barium meal series on three cases, endoscopic ultrasonography (EUS) on three cases, and MRI on one case. Results All tumors presented well-encapsulated heterogeneous soft tissue mass with varying degrees of solid and cystic components. Barium meal examination showed displaced gastrointestinal wall due to the tumoral compression. EUS demonstrated hyper-echoic mass with scattered small anechoic areas within the tumor. The tumor capsules were hyper-echoic. On un-enhanced CT, the mass appeared hypo-dense with mixed solid and cystic portions in six cases, and with predominantly cystic portion in one case. Calcification appeared in two cases. On biphasic enhanced CT, the mass showed peripheral and heterogeneous enhancement. Three tumors showed marked enhancement, and four tumors showed mild enhancement. Multiple small vessels within the tumor revealed on the arterial phase scanning in one case. The tumor capsules showed discontinuous enhancement in three cases. On T 1 WI, the mass appeared heterogeneous and predominantly isodense. On T 2 WI, the mass appeared heterogeneous and predominantly hyper-dense. The tumor capsule was hypo-dense on T 1 WI and T 2 WI. The mild dilatation of the biliary tract and pancreatic duct was revealed in two cases, respectively. Conclusion: Both CT and MRI can describe characteristic features of SPTP well, and should be used as the main diagnostic methods for SPTP before operation. (authors)

  6. FDG PET/CT对骨及软组织肿瘤诊断和疗效评价的应用%FDG PET/CT imaging in the diagnosis and efficacy evaluation for bone and soft tissue tumors

    Institute of Scientific and Technical Information of China (English)

    刘健; 赵涛; 吕杰; 孙波; 张鹏

    2011-01-01

    Objective To assess the clinical value of FDG PET/CT imaging in the diagnosis and efficacy evaluation for bone and soft tissue tumors.Methods The FDG PET/CT images of 48 patients diagnosed with bone and soft tissue tumors were retrospectively analyzed.These FDG PET/CT images were analyzed in order to differentially diagnose the tumors to be benign or malignant, and to confirm whether there was recurrence, distal metastasis and surrounding invasion or not.Besides, comparative analysis was done between the FDG PET/CT imaging and the CT imaging.Results For FDG PET/CT imaging in the diagnosis for bone and soft tissue tumors, the rate of sensitivity was10O% (7/7), and the rate of specificity was 80% (4/5).According to the monitoring results of recurrence and residual,both the post-operative rate of sensitivity and the post-operative rate of specificity were 1O0%.Extra 35 metastases were detected by the PET/CT imaging, and the other 12 pulmonary metastases were found by the CT imaging.Conclusions FDG PET/CT imaging in the diagnosis for bone and soft tissue tumors is better than the routine imaging.It can accurately detect the recurrence of tumors in the early stage, and find extra metastasis (except pulmonary metastasis).Therefore, it can assist the treatment and diagnosis against tumors.%目的 探讨FDG PET/CT显像诊断骨或软组织肿瘤和术后疗效评价的价值.方法 回顾性分析48例已证实的骨及软组织肿瘤患者的FDG PET/CT显像结果,以鉴别诊断肿瘤的良恶性,是否复发、有无其他转移及周围侵犯,并与同机CT对比分析.结果 FDG PET/CT显像诊断骨及软组织肿瘤灵敏度为100%(7/7),特异性为80%(4/5);监测术后复发(残留)的灵敏度和特异性均为100%;通过PET/CT显像多发现转移灶35处,对于肺部12个转移灶,有赖于同机CT.结论 FDG PET/CT显像对骨及软组织肿瘤的诊断优于常规影像检查,可早期准确判断肿瘤复发,同时发现更多转移灶(肺转移除外),对肿瘤治疗诊断有指导作用.

  7. The usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region

    International Nuclear Information System (INIS)

    Grzesiakowska, U.; Tacikowska, M.; Krajewski, R.; Starosciak, S.; Smorczewska, M.; Wiszniewska-Rawlik, D.

    2005-01-01

    The aim of the study was to determine the usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region. All the patients were treated surgically. CT and/or MR imaging was done in every patient for preoperative evaluation of soft tissue infiltration, destruction of bone structures, and metastasis of lymph nodes of the head and neck. The results of these imagings were compared with surgical evaluations and microscopic examination of postoperative specimens. Both CT and MR imaging have high accuracy in evaluating soft tissue infiltration. CT imaging is much better than MR in evaluating bony destruction. MR imaging is better in evaluating recurrent tumors, in which CT has very low specificity. MR imaging is the only method for evaluating infiltration of the central nervous system.The authors propose the following diagnostic algorithm: CT imaging for initial evaluation before treatment, MR imaging in suspected cases of infiltration of the central nervous system, and MR imaging in recurrent tumors after surgical and radiation treatment. (author)

  8. CT and MR findings of primitive neuroectodermal tumor

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Kim, In One; Chang, Kee Hyun; Han, Moon Hee; Cho, Byung Kyu

    1991-01-01

    Cerebral primitive neuroectodermal tumor (PNET), consisting of undifferentiated primitive cells, is a neoplasm of children and young adults that occurs predominantly in the supratentorial compartment. In this report, we retrospectively reviewed and analyzed 18 CT and 6 MR findings in 18 patients with pathologically-proven PNET to discover the characteristic findings, if may. The most characteristic feature of the PNETs was a well-defined multilobular oval or round large mass with components of peripheral cystic change or calcification in the cerebral hemisphere, especially in the parietal lobe. Usually there was only minimal surrounding edema. The CT density of the tumor was iso - or slightly high density with homogeneous contrast enhancement in the solid portion and low density in the cystic area. MR findings demonstrated iso - signal intensity on both T1 - weighted (T1WI) and T2-weighted (T2WI) images and dense enhancement in the solid element. The cystic portion revealed low intensity on T1WI and high intensity on T2WI

  9. CT-sialographic evaluation of 19 cases of alivary gland tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tadashi [Komoro Kousei General Hospital, Nagano (Japan)

    1999-09-01

    Sixteen patients with parotid gland tumors and 3 patients with submandibular gland tumors were evaluated by CT sialography. The 19 patients were 5 to 78 years old, mean age: 57.3 years. CT sialography was performed preoperatively, and postoperative histological examination indicated that the tumors were benign in 13, a cyst in 1, malignant tumors in 4, and a malignant lymphoma in 1 patient. The tumorous lesion detection rate by CT sialography was 100%. The major duct was visualized in all patients, and the examination was informative about the special relationship between the tumor and the facial nerve. No sign of malignancy was noted in an epithelialmyoepithelial carcinoma of 10 mm in diameter on CT sialography. In 2 patients adhesion to surrounding tissues observed intraoperatively was judged to be benign tumors by CT sialography. The marginal morphology of the tumor and the presence or absence of low density areas and punctuate leakage in the interior of the tumor were useful for the judgement of malignancy of salivary gland tumors. CT sialography, which provides diverse information on the location and morphology of the tumor, should be performed early for the diagnosis of salivary gland tumors. (author)

  10. Diffusion-weighted MR imaging vs. multi-detector row CT: Direct comparison of capability for assessment of management needs for anterior mediastinal solitary tumors

    International Nuclear Information System (INIS)

    Seki, Shinichiro; Koyama, Hisanobu; Ohno, Yoshiharu; Nishio, Mizuho; Takenaka, Daisuke; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2014-01-01

    Purpose: To evaluate and compare the capability of diffusion-weighted MR imaging (DWI) and CT for assessment of management needs for anterior mediastinal solitary tumors. Materials and methods: Thirty-five patients with pathologically confirmed anterior mediastinal tumors were enrolled. The tumors were divided into two groups according to need for management: tumors not needing further intervention or treatment (group A; thymoma type A, AB and B1) and tumors needing further intervention and treatment (group B; other thymoma types and malignancies). The apparent diffusion coefficient (ADC) of each tumor was measured, and probabilities of malignancy and need for further intervention and treatment were visually assessed on CT. The differences in ADCs between group A and B and between malignancies and thymomas in group B were evaluated with the Mann–Whitney's U-test. Feasible threshold values for differentiation of group B from group A and distinguishing malignancies from thymomas assessed as group B were determined by the ROC-based positive test, and McNemar's test was used for comparing diagnostic capabilities of DWI with those of CT. Results: ADCs for the two groups were significantly different (p < 0.001). Application of the threshold value for differentiation of group B from A showed no significant difference (p > 0.05). Application of the feasible threshold value for distinguishing malignant from thymomas assessed as group B showed that specificity (76.9%) and accuracy (85.2%) of DWI were significantly better than those of visual score (p < 0.05). Conclusion: DWI has useful potential for the assessment of management needs for anterior mediastinum solitary tumors as well as CT

  11. Application of CT perfusion imaging in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Xia Guangrong; Liu Guimei; He Wen; Jin Guohua; Xie Ruming; Xu Yongxiang; Li Xiaobo; Li Xuebing

    2011-01-01

    Objective: To investigate the value of CT perfusion imaging in evaluation of therapeutic effect and prognosis in radiotherapy for lung cancer. Methods: Fifty-one cases of lung cancer who were unable or refused to be operated on, 36 males and 15 females, aged 37-80, underwent CT perfusion imaging, 29 of which only before radiotherapy and 22 before and after radiotherapy twice. The images were collected by cine dynamic scanning (5 mm/4 slices) and input into the GE AW4.0 workstation for data processing. The slice positions of CT imaging were determined according to the largest tumor size in CT scan. Regions of interest of tumor were drawn at the region corresponding to the original images of CT perfusion. Radiotherapy was performed after CT perfusion imaging. Relevant parameters, including blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) were calculated. The treatment response after radiotherapy was evaluated by RECIST. At 2 -4 weeks after the treatment, CT examination was conducted once more. Results: The tests of the 51 patients showed that the BV was 13.6 ml·100 g -1 , the BF was 129.5 ml·min -1 ·100 g -1 , the MTT was 9.1 s, and the PS was 10.0 ml· min -1 · 100 g -1 before radiotherapy. The tests of the 22 of the 51 patients showed that the values of BV and BF after radiotherapy were 7.6 ml· 100 g -1 and 97.8 ml·min -1 · 100 g -1 , respectively, both lower than those before radiotherapy (11.2 and 108.7 ml·min -1 ·100 g -1 , respectively), however, both not significantly (t=1.28, 0.40, P>0.05); and the values of MTT and PS after radiotherapy were 8.9 s and 7.8 ml·min -1 · 100 g -1 , respectively, both not significantly higher than those before radiotherapy (7.2 s and 6.8 ml· min -1 · 100 g -1 , respectively, t=-1.15, -0.57, P>0.05). The mean area of tumor after radiotherapy was 1189.6 mm 2 , significantly less than that before radiotherapy (1920.3 mm 2 , t=3.98, P<0.05). The MTT of the SCLC patients was 12

  12. (CT, MRI, USG) radiological diagnostics of neuroendocrine tumors

    International Nuclear Information System (INIS)

    Cwikla, J.; Furmanek, M.; Walecki, J.; Sankowski, A.; Pawlowska-Detko, A.

    2007-01-01

    Neuroendocrine tumors (NET) consists of a heterogeneneous group of neoplasma, that are able to express cell membrane neuroamine uptake mechanisms and/or specific receptors, which can be used in the localization and treatment of these tumours. Conventionally NETs may present with a wide variety of functional or nonfuctional endocrinesyndromes and may be familial and have other associated tumors, also they have different histology and prognosis. They originate from endocrine glands such as the pituitary, the parathyroids, and the neuroendocrine) adrenal, as well as endocrine islets within glandular tissue (thyroid or pancreatic) and cells dispersed between exocrine cells, such as endocrine cells of the digestive system (gastroenteropancreatic GEP-NET0 and respiratory tracts. GEp-NET are the the most common including more 70% of all NETs. Imaging modalities and assessment of specific tumors markers offers high sensitivity in establishing the diagnosis and can also have pronostic significance. One of most important single imaging techniques in terms of initial identification and staging o GET-NET are CT and somatostatin receptor scintigraphy (SRS). Other investigation like magnetic resonance imaging (MRI), endoscopic (EUS) are used for the precise localization of GEP-NET. Another techniques including functional approach 123 I MIBG (meta-iodobenzylguanidine scintigraphy) and FDG PET.Important using of imaging approach is monitoring of response on treatment. (author)

  13. Quantitative Segmentation of Fluorescence Microscopy Images of Heterogeneous Tissue: Application to the Detection of Residual Disease in Tumor Margins.

    Science.gov (United States)

    Mueller, Jenna L; Harmany, Zachary T; Mito, Jeffrey K; Kennedy, Stephanie A; Kim, Yongbaek; Dodd, Leslie; Geradts, Joseph; Kirsch, David G; Willett, Rebecca M; Brown, J Quincy; Ramanujam, Nimmi

    2013-01-01

    To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features. TISSUE EXCISED FROM A GENETICALLY ENGINEERED MOUSE MODEL OF SARCOMA WAS IMAGED USING A SUBCELLULAR RESOLUTION MICROENDOSCOPE AFTER TOPICAL APPLICATION OF A FLUORESCENT ANATOMICAL CONTRAST AGENT: acriflavine. An algorithm based on sparse component analysis (SCA) and the circle transform (CT) was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma. Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity). For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach. The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue.

  14. Magnetic resonance imaging of nasopharyngeal malignant tumors

    International Nuclear Information System (INIS)

    Sakakihara, Junji; Kanoh, Naoyuki; Hayakawa, Katsumi.

    1988-01-01

    Magnetic Resonance Imaging (MRI) was used in the examination of three patients with nasopharyngeal malignant tumor and cranial nerve symptoms. Coronal and saggital sections were very useful for determining skull base invasion. Its high contrast resolution enabled us to visualize several cranial nerves directly. Differentiation between tumor and effusion in the paranasal sinuses was easy especially in T2 weighted images. Bone destruction could also be detected as bone marrow replacement by tumor or as interruption of the black line of compact bone. Local relationships of tumor and large blood vessels were visualized by MRI without invasive contrast enhancing methods. Despite such advantages, in one patient whose symptoms were highly suggestive of cranial invasion, no cranial invasion was detected by CT or MRI. (author)

  15. Evaluation of Effective Parameters on Quality of Magnetic Resonance Imaging-computed Tomography Image Fusion in Head and Neck Tumors for Application in Treatment Planning

    Directory of Open Access Journals (Sweden)

    Atefeh Shirvani

    2017-01-01

    Full Text Available Background: In radiation therapy, computed tomography (CT simulation is used for treatment planning to define the location of tumor. Magnetic resonance imaging (MRI-CT image fusion leads to more efficient tumor contouring. This work tried to identify the practical issues for the combination of CT and MRI images in real clinical cases. The effect of various factors is evaluated on image fusion quality. Materials and Methods: In this study, the data of thirty patients with brain tumors were used for image fusion. The effect of several parameters on possibility and quality of image fusion was evaluated. These parameters include angles of the patient's head on the bed, slices thickness, slice gap, and height of the patient's head. Results: According to the results, the first dominating factor on quality of image fusion was the difference slice gap between CT and MRI images (cor = 0.86, P 4 cm and image fusion quality was <25%. Conclusion: The most important problem in image fusion is that MRI images are taken without regard to their use in treatment planning. In general, parameters related to the patient position during MRI imaging should be chosen to be consistent with CT images of the patient in terms of location and angle.

  16. Usefulness of emission CT in 67Ga tumor and inflammation scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Tada, Akira; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi.

    1983-01-01

    67 Ga-citrate widely used for tumor imaging has some drawbacks. Poor blood elearance of 67 Ga is sometimes a cause of poor visualization of the abnormal uptake in lesions. Physiological accumulations of 67 Ga (e. g. liver, colon, pulmonary hilus, etc.) also conceal the abnormal 67 Ga uptake in lesions. We have evaluated the usefulness of 67 Ga SPECT (single photon emission CT) to overcome these drawbacks inherent in conventional gamma-camera images. 67 Ga SPECT was more useful to recognize the location and the extension of lesions in transaxial planes, therefore, comparison of the lesions with transmission CT was easily made. Abnormal accumulation in or near the liver was easily discriminated from the physiological accumulation of 67 Ga in the liver. Further evaluation of the lesions which had been detected by other imaging methods (e. g. transmission CT, ultrasonography, etc.), 67 Ga SPECT was more useful than conventional gamma-camera imaging. In conclusion, 67 Ga SPECT was useful in selected cases when performed after conventiond 67 Ga imaging. (author)

  17. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  18. The value of {sup 18}F-FDG PET/CT in the management of malignant peripheral nerve sheath tumors

    Energy Technology Data Exchange (ETDEWEB)

    Khiewvan, Benjapa [University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Mahidol University, Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine Siriraj Hospital, Bangkok (Thailand); Macapinlac, Homer A.; Chuang, Hubert H. [University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Lev, Dina; Al Sannaa, Ghadah [University of Texas MD Anderson Cancer Center, Department of Cancer Biology, Houston, TX (United States); McCutcheon, Ian E. [University of Texas MD Anderson Cancer Center, Department of Neurosurgery, Houston, TX (United States); Slopis, John M. [University of Texas MD Anderson Cancer Center, Department of Neuro-Oncology, Houston, TX (United States); Wei, Wei [University of Texas MD Anderson Cancer Center, Department of Biostatistics, Houston, TX (United States)

    2014-09-15

    Our objective was to determine how positron emission tomography (PET)/CT had been used in the clinical treatment of malignant peripheral nerve sheath tumor (MPNST) patients at The University of Texas MD Anderson Cancer Center. We reviewed a database of MPNST patients referred to MD Anderson Cancer Center during 1995-2011. We enrolled 47 patients who underwent PET/CT imaging. Disease stage was based on conventional imaging and PET/CT findings using National Comprehensive Cancer Network (NCCN) guidelines. Treatment strategies based on PET/CT and conventional imaging were determined by chart review. The maximum and mean standardized uptake values (SUV{sub max}, SUV{sub mean}), metabolic tumor volume (MTV), total lesion glycolysis (TLG), change in SUV{sub max}, change in MTV, and change in TLG were calculated from the PET/CT studies before and after treatment. Response prediction was based on imaging studies performed before and after therapy and categorized as positive or negative for residual tumor. Clinical outcome was determined from chart review. PET/CT was performed for staging in 16 patients, for restaging in 29 patients, and for surveillance in 2 patients. Of the patients, 88 % were correctly staged with PET/CT, whereas 75 % were correctly staged with conventional imaging. The sensitivity to detect local recurrence and distant metastasis at restaging was 100 and 100 % for PET/CT compared to 86 and 83 % for conventional imaging, respectively. PET/CT findings resulted in treatment changes in 31 % (5/16) and 14 % (4/29) of patients at staging and restaging, respectively. Recurrence, MTV, and TLG were prognostic factors for survival, whereas SUV{sub max} and SUV{sub mean} were not predictive. For 21 patients who had imaging studies performed both before and after treatment, PET/CT was better at predicting outcome (overall survival, progression-free survival) than conventional imaging. A decreasing SUV{sub max} ≥ 30 % and decrease in TLG and MTV were significant

  19. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  20. High-field MR imaging of spinal cord tumors

    International Nuclear Information System (INIS)

    Halimi, P.; Sigal, R.; Blas, C.; Doyon, D.; Hurth, M.; Bittoun, J.

    1986-01-01

    In 60 patients with spinal cord tumors, MR imaging was performed using a 1.5-T unit (GE Signa) and a planar surface coil, 5-mm-thick sections, and spin-echo pulse sequences (TE/TR = 25/600 and 25-100/2,000-2,500 msec). There were 32 astrocytomas, 13 ependymomas, and five hemangioblastomas. Ten patients were not operated on. Surgical follow-up was available in 35 patients. The MR imaging results were correlated with findings on CT, myelography, intraoperative US, surgery, and pathologic examination. In all cases the tumor appeared markedly inhomogeneous. Four imaging patterns corresponding to structural abnormalities were observed: low signal intensity of the tumor core on both T1- and T2-weighted images; hypointensity on T1-weighted images and hyperintensity on T2-weighted images (low-protein cyst, syrinx, edema); isointensity on T1-weighted and slight hypertensity on T2-weighted images (high-protein tumoral necrotic cyst); and high spinal intensity on both T1- and T2-weighted images (chronic hemorrhage). MR imaging contributes the most information in the diagnosis of spinal cord tumors and delineation of their extent, and consequently has a potential impact on surgical management

  1. Diagnosis of intracranial tumors by CT (computerized tomography) from a practical point of view

    Energy Technology Data Exchange (ETDEWEB)

    Elke, M; Wiggli, U; Huenig, R [Basel Univ. (Switzerland). Inst. fuer Medizinische Radiologie

    1977-04-01

    In a historical abstract the mathematical basis of image reconstruction techniques and CT is reviewed. The enhancement of iodine contrast media is essential in CT diagnostis of space occupying intracranial lesions. Intracranial tumors usually show relatively characteristical but mostly non-specific absorption patterns. Additional clinical information is necessary for differential diagnostic evalution. The development of tables with various tumor patterns is recommended. Absorption feature of primary and secondary brain-tumors with the surrounding edema is explained. Glioblastomas as well as metastases often show a distinct cerebral edema which has been observed in 64% of our patients with metastases and distinctly localized high dense foci in 69%. 6,000 patients were investigated by CT and 1,708 examinations were performed with contrast enhancement. Side-effects are within the known reaction of other intravenously applicated contrast media.

  2. TU-H-CAMPUS-JeP2-03: Machine-Learning-Based Delineation Framework of GTV Regions of Solid and Ground Glass Opacity Lung Tumors at Datasets of Planning CT and PET/CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, K; Arimura, H; Jin, Z; Yabuuchi, H; Sasaki, T; Honda, H; Sasaki, M [Kyushu University, Fukuoka, Fukuoka (Japan); Kuwazuru, J [Saiseikai Fukuoka General Hospital, Fukuoka, Fukuoka (Japan); Shioyama, Y [Saga Heavy Ion Medical Accelerator in Tosu, Tosu, Saga (Japan)

    2016-06-15

    Purpose: In radiation treatment planning, delineation of gross tumor volume (GTV) is very important, because the GTVs affect the accuracies of radiation therapy procedure. To assist radiation oncologists in the delineation of GTV regions while treatment planning for lung cancer, we have proposed a machine-learning-based delineation framework of GTV regions of solid and ground glass opacity (GGO) lung tumors following by optimum contour selection (OCS) method. Methods: Our basic idea was to feed voxel-based image features around GTV contours determined by radiation oncologists into a machine learning classifier in the training step, after which the classifier produced the degree of GTV for each voxel in the testing step. Ten data sets of planning CT and PET/CT images were selected for this study. The support vector machine (SVM), which learned voxel-based features which include voxel value and magnitudes of image gradient vector that obtained from each voxel in the planning CT and PET/CT images, extracted initial GTV regions. The final GTV regions were determined using the OCS method that was able to select a global optimum object contour based on multiple active delineations with a level set method around the GTV. To evaluate the results of proposed framework for ten cases (solid:6, GGO:4), we used the three-dimensional Dice similarity coefficient (DSC), which denoted the degree of region similarity between the GTVs delineated by radiation oncologists and the proposed framework. Results: The proposed method achieved an average three-dimensional DSC of 0.81 for ten lung cancer patients, while a standardized uptake value-based method segmented GTV regions with the DSC of 0.43. The average DSCs for solid and GGO were 0.84 and 0.76, respectively, obtained by the proposed framework. Conclusion: The proposed framework with the support vector machine may be useful for assisting radiation oncologists in delineating solid and GGO lung tumors.

  3. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  4. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion.

    Science.gov (United States)

    Yang, Y X; Teo, S-K; Van Reeth, E; Tan, C H; Tham, I W K; Poh, C L

    2015-08-01

    Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors' proposed approach. A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  5. Evaluation of a New Motion-correction Algorithm Using On-rigid Registration in Respiratory-gated PET/CT Images of Liver Tumors.

    Science.gov (United States)

    Wagatsuma, Kei; Osawa, Tatsufumi; Yokokawa, Naoki; Miwa, Kenta; Oda, Keiichi; Kudo, Yoshiro; Unno, Yasushi; Ito, Kimiteru; Ishii, Kenji

    2016-01-01

    The present study aimed to determine the qualitative and quantitative accuracy of the Q.Freeze algorithm in PET/CT images of liver tumors. A body phantom and hot spheres representing liver tumors contained 5.3 and 21.2 kBq/mL of a solution containing 18 F radioactivity, respectively. The phantoms were moved in the superior-inferior direction at a motion displacement of 20 mm. Conventional respiratory-gated (RG) and Q.Freeze images were sorted into 6, 10, and 13 phase-groups. The SUV ave was calculated from the background of the body phantom, and the SUV max was determined from the hot spheres of the liver tumors. Three patients with four liver tumors were also clinically assessed by whole-body and RG PET. The RG and Q.Freeze images derived from the clinical study were also sorted into 6, 10 and 13 phase-groups. Liver signal-to-noise ratio (SNR) and SUV max were determined from the RG and Q.Freeze clinical images. The SUV ave of Q.Freeze images was the same as those derived from the body phantom using RG. The liver SNR improved with Q.Freeze, and the SUVs max was not overestimated when Q.Freeze was applied in both the phantom and clinical studies. Q.Freeze did not degrade the liver SNR and SUV max even though the phase number was larger. Q.Freeze delivered qualitative and quantitative motion correction than conventional RG imaging even in 10-phase groups.

  6. CT features of the subtypes of thymic epithelial tumors on the basis of the world health organization classification

    International Nuclear Information System (INIS)

    Guo Xiaoyu; Yu Hong; Xiao Xiangsheng

    2013-01-01

    Thymic epithelial tumors including thymomas and thymic carcinomas have well-known heterogeneous oncologic behaviors and variable histologic features. They show variable and unpredictable evolutions ranging from an indolent non-invasive feature to a highly infiltrative and metastasising one. Currently, CT is a common and efficient imaging method for assessing thymic epithelial tumors. CT evaluation is the main reference for preoperative clinic staging and histological classification. CT features of subtypes of thymic epithelial tumors on the basis of the World Health Organization classification provide the foundation for the diagnosis and predicting prognosis. (authors)

  7. CT morphology of benign median nerve tumors

    International Nuclear Information System (INIS)

    Feyerabend, T.; Schmitt, R.; Lanz, U.; Warmuth-Metz, M.; Wuerzburg Univ.

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.)

  8. The performance and application of 18F-FDG PET/CT in diagnosis of tumor

    International Nuclear Information System (INIS)

    Wang Junqi

    2004-01-01

    Positron emission tomography (PET)/computed tomography (CT) inline scanner combined with high performance PET and CT have been introduced to clinical in recent years. The application of PET/CT in oncology are rapid increasing. The addition of CT to PET offers many advantages, including obtaining a fast and relatively accurate transmission map, shortening the duration of the examination, adding precise anatomical information to PET imaging, and providing additional diagnostic information. However, using CT for attenuation correction can led to some artifacts; quantitative measurements may be altered, high density IV and oral metallic objects may produce artifacts, and the registration of PET and CT may occasionally suboptimal. In head and neck tumor PET/CT offers particular potential advantages as well as abdomen and pelvic tumor. Even in the thorax, which the physical movement may produce unsatisfactory results, offers some advantages also. Preliminary results of PET/CT over PET or CT in oncology are very encouraging. It is clear the PET/CT fusion technology has an more and more impact on both diagnostic and therapeutic aspects of patient management

  9. The diagnosis and therapeutic gain using US, CT and MRI. Submucosal tumors in stomach and duodenum

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Shinichi; Nawano, Shigeru; Tajiri, Hisao; Boku, Narikazu; Muto, Manabu; Ohtsu, Atsushi; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Moriyama, Noriyuki

    1999-02-01

    The usefulness of the ultrasonography (US), the computed tomography (CT) and the magnetic resonance imaging (MRI) was examined. The subjects were 19 patients with submucosal leiomyoma and leiomyosarcoma in the stomach and duodenum which had surgery and were histologically diagnosed in the National Cancer Center Hospital. The detectability of the primary foci was 50% (8/16) in US, and 93% (13/14) in EUS (the endoscopic ultrasonography) which makes the structure of the stomach wall and the continuity of tumors clear. CT could detect the primary foci in 94% (16/17) and was excellent to know not only the presence of the remote metastases but also the exact size and expanse of the tumors. In all cases of leiomyoma, tumors were leiomyosarcoma when the internal structure was diagnosed to be heterogeneous by both EUS and CT, or either of them. The qualitative image diagnosis is not always easy in gastrointestinal submucosal tumors, but it is important to generally diagnose by the combination with several examinations in order to select the suitable therapeutic method. (K.H.)

  10. Analysis of the manifestation and feature of adrenal tumor on CT in 30 cases

    International Nuclear Information System (INIS)

    Xi Riquan; Xie Daohai; Guo Liang; Hu Chunhong; Fu Yingdi

    2001-01-01

    Objective: To analyze the manifestation and the feature of adrenal tumor with CT. Methods: The findings of various adrenal tumors with CT in 30 cases were analyzed retrospectively, the key to the diagnosis and differential diagnosis was suggested. Results: Usually, fibroxanthoma is inhomogeneous in density and moderate in size and was enhanced slightly after contrast medium administration. Pheochromocytoma is always larger and inhomogeneous in density and was enhanced markedly. The CT unit of myelo-lipoma simulated those of fluid or fat. Adrenal cyst has a low CT value and it showed cystic wall calcification. Aldosteronism adenoma was low in density and small in size, while cortisol adenoma was moderate in density and medium in size. Adrenocortical adenocarcinoma was the larger one with irregular margin and irregular hypodense areas inside. Metastatic carcinoma was larger and inhomogeneous in density. Conclusion: It is possible to increase the diagnostic rate by analysing the imaging feature of adrenal tumor

  11. Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

    International Nuclear Information System (INIS)

    Nakamura, Mitsuhiro; Miyabe, Yuki; Matsuo, Yukinori; Kamomae, Takeshi; Nakata, Manabu; Yano, Shinsuke; Sawada, Akira; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-01-01

    The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A 1 ) was set in the range of 0.0–12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of γ index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within ± 0.7%. From the dose area histograms on the film, the mean ± standard deviation of the dose covering 100% of the cross section of the target was 102.32 ± 1.20% (range, 100.59–103.49%). By contrast, the irradiated areas receiving more than 95% dose for A 1 = 12 mm were 1.46 and 1.33 times larger than those for A 1 = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

  12. Quantitative Segmentation of Fluorescence Microscopy Images of Heterogeneous Tissue: Application to the Detection of Residual Disease in Tumor Margins.

    Directory of Open Access Journals (Sweden)

    Jenna L Mueller

    Full Text Available To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features.TISSUE EXCISED FROM A GENETICALLY ENGINEERED MOUSE MODEL OF SARCOMA WAS IMAGED USING A SUBCELLULAR RESOLUTION MICROENDOSCOPE AFTER TOPICAL APPLICATION OF A FLUORESCENT ANATOMICAL CONTRAST AGENT: acriflavine. An algorithm based on sparse component analysis (SCA and the circle transform (CT was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma.Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity. For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach.The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue.

  13. Diagnostic difficulties in the differentiation of neurogenic tumors of the parapharyngeal space in helical CT evaluations: A case report

    International Nuclear Information System (INIS)

    Czerniewicz-Kaminska, A.; Nowicki, J.; Jazwiec, P.; Kedzierski, B.; Janeczek, T.; Wilczynski, K.; Prudlak, E.

    2005-01-01

    Computerized tomography (CT) with contrast infusion and magnetic resonance imaging (MRI) play important roles in establishing the place of origin of neurogenic tumors. In this article we do not compare these two methods, but focus on the crucial role of CT imaging in the estimation and differential diagnosis of these tumors. We present the case of a 50-year-old man with clinical symptoms of peritonsillar abscess, which appeared to be a neurogenic tumor. The images obtained were deemed ambiguous. The possibility of a parotid gland tumor or a tumor of neurogenic origin was assumed. In this case we observed atypical clinical and radiological symptoms. The final diagnosis was based on a combination of radiological, clinical, and microbiological features of the tumor. Thanks to the cooperation of many professionals, we managed to establish the diagnosis of neuroangiofibroma, which exemplifies a tumor of the borderline, including elements of the neurogenic sheath and connective and chromaffin tissue. (author)

  14. Comparison of applied dose and image quality in staging CT of neuroendocrine tumor patients using standard filtered back projection and adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Böning, G; Schäfer, M; Grupp, U; Kaul, D; Kahn, J; Pavel, M; Maurer, M; Denecke, T; Hamm, B; Streitparth, F

    2015-08-01

    To investigate whether dose reduction via adaptive statistical iterative reconstruction (ASIR) affects image quality and diagnostic accuracy in neuroendocrine tumor (NET) staging. A total of 28 NET patients were enrolled in the study. Inclusion criteria were histologically proven NET and visible tumor in abdominal computed tomography (CT). In an intraindividual study design, the patients underwent a baseline CT (filtered back projection, FBP) and follow-up CT (ASIR 40%) using matched scan parameters. Image quality was assessed subjectively using a 5-grade scoring system and objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs). Applied volume computed tomography dose index (CTDIvol) of each scan was taken from the dose report. ASIR 40% significantly reduced CTDIvol (10.17±3.06mGy [FBP], 6.34±2.25mGy [ASIR] (pASIR]) (pASIR]) (pASIR]), visibility of suspicious lesion (4.8±0.5 [FBP], 4.8±0.5 [ASIR]) and artifacts (5.0±0 [FBP], 5.0±0 [ASIR]). ASIR 40% significantly decreased scores for noise (4.3±0.6 [FBP], 4.0±0.8 [ASIR]) (pASIR]) (pASIR]) (pASIR can be used to reduce radiation dose without sacrificing image quality and diagnostic confidence in staging CT of NET patients. This may be beneficial for patients with frequent follow-up and significant cumulative radiation exposure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. The role of CT in diagnosing small hepatic tumors

    International Nuclear Information System (INIS)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi

    1992-01-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author)

  16. Clinical application of early PET-CT imaging after radiofrequency ablation of liver neoplasms

    International Nuclear Information System (INIS)

    Liu Zhaoyu; Chang Zhihui; Lu Zaiming; Xin Jun; Wang Xiaoming; Guo Qiyong

    2009-01-01

    Objective: To evaluate the application of early 18 F-FDG PET-CT imaging after radiofrequency ablation (RFA) of hepatic malignancies. Methods: Fifteen patients with liver tumors (five hepatocellular carcinoma, ten colorectal cancer liver metastasis) underwent RFA as part of clinical management. The lesions were all hypermetabolic on PET-CT performed within 2 weeks prior to RFA. All subjects underwent 18 F-FDG PET-CT (early PET-CT) within 24 hours after RFA. Total photopenia, focal uptake, and rim-shaped uptake were regarded as complete ablation, residual tumor, and inflammation, respectively. Follow-up PET-CT scans were performed as the reference standard. Results: Twelve patients showed total photopenia at the ablation site on the early PET-CT scan, and in all of these patients, total photopenia at the ablation sites was seen on the follow-up PET-CT scans. Two patients had focal uptake at the ablation sites on the early PET-CT scan, and both of these foci increased in size and intensity, which were compatible with residual tumors at the time of ablation. Only one patient had rim-shaped uptake on the early PET-CT scan. The rim-shaped uptake disappeared on PET-CT performed 3 months later, which indicated the nature of inflammation. Conclusions: There is infrequent inflammatory uptake at the RFA site of liver tumors on 18 F-FDG PET-CT if scanning is performed within 24 hours after ablation. Thus, early PET- CT has the potential to evaluate the efficacy of an RFA procedure by indicating tumor-free as total photopenia and residual tumors as focal uptake. (authors)

  17. CT and MR imaging of gynecological emergency disease

    International Nuclear Information System (INIS)

    Fujii, Shinya; Kinoshita, Toshibumi; Tahara, Takatoshi; Matsusue, Eiji; Ogawa, Toshihide

    2004-01-01

    We describe the CT and MRI findings of gynecologic emergency diseases: pelvic inflammatory disease, ectopic pregnancy, ovarian hemorrhage, ovarian torsion, rupture of ovarian tumor, eclampsia, and HELLP (hemolysis, elevated liver enzymes, and low platelet count) syndrome. Diagnostic keys to these diseases are presented in this review. CT and MRI play a complementary role to sonography in accurately diagnosing these diseases. In situations that require an exact, immediate diagnosis, radiologists should be familiar with the key imaging findings. (author)

  18. PET CT imaging: the Philippine experience

    International Nuclear Information System (INIS)

    Santiago, Jonas Y.

    2011-01-01

    Currently, the most discussed fusion imaging is PET CT. Fusion technology has tremendous potential in diagnostic imaging to detect numerous conditions such as tumors, Alzheimer's disease, dementia and neural disorders. The fusion of PET with CT helps in the localization of molecular abnormalities, thereby increasing diagnostic accuracy and differentiating benign or artefact lesions from malignant diseases. It uses a radiotracer called fluro deoxyglucose that gives a clear distinction between pathological and physiological uptake. Interest in this technology is increasing and additional clinical validation are likely to induce more health care providers to invest in combined scanners. It is hope that in time, a better appreciation of its advantages over conventional and traditional imaging modalities will be realized. The first PET CT facility in the country was established at the St. Luke's Medical Center in Quezon City in 2008 and has since then provided a state-of-the art imaging modality to its patients here and those from other countries. The paper will present the experiences so far gained from its operation, including the measures and steps currently taken by the facility to ensure optimum workers and patient safety. Plans and programs to further enhance the awareness of the Filipino public on this advanced imaging modality for an improved health care delivery system may also be discussed briefly. (author)

  19. Primary diaphyseal osteosarcoma in long bones: Imaging features and tumor characteristics

    International Nuclear Information System (INIS)

    Wang, Cheng-Sheng; Yin, Qi-Hua; Liao, Jin-Sheng; Lou, Jiang-Hua; Ding, Xiao-Yi; Zhu, Yan-Bo; Chen, Ke-Min

    2012-01-01

    Objective: This study aims to assess retrospectively the imaging features of diaphyseal osteosarcoma and compare its characteristics with that of metaphyseal osteosarcoma. Materials and methods: Eighteen pathologically confirmed diaphyseal osteosarcomas were reviewed. Images of X-ray (n = 18), CT (n = 12) and MRI (n = 15) were evaluated by two radiologists. Differences among common radiologic findings of X-ray, CT and MRI, and between diaphyseal osteosarcomas and metaphyseal osteosarcomas in terms of tumor characteristics were compared. Results: The common imaging features of diaphyseal osteosarcoma were bone destruction, lamellar periosteal reaction with/without Codman triangle, massive soft tissue mass/swelling, neoplastic bone and/or calcification. CT and MRI had a higher detection rate in detecting bone destruction (P = 0.001) as compared with that of X-ray. X-ray and CT resulted in a higher percentage in detecting periosteal reaction (P = 0.018) and neoplastic bone and/or calcification (P = 0.043) as compared with that of MRI. There was no difference (P = 0.179) in detecting soft tissue mass among three imaging modalities. When comparing metaphyseal osteosarcoma to diaphyseal osteosarcoma, the latter had the following characteristics: a higher age of onset (P = 0.022), a larger extent of tumor (P = 0.018), a more osteolytic radiographic pattern (P = 0.043). Conclusion: As compared with metaphyseal osteosarcoma, diaphysial osteosarcoma is a special location of osteosarcoma with a lower incidence, a higher age of onset, a larger extent of tumor, a more osteolytic radiographic pattern. The osteoblastic and mixed types are diagnosed easily, but the osteolytic lesion should be differentiated from Ewing sarcoma. X-ray, CT and MRI can show imaging features from different aspects with different detection rates.

  20. Assessment of intratumor hypoxia by integrated 18F-FDG PET / perfusion CT in a liver tumor model.

    Directory of Open Access Journals (Sweden)

    Yong Wang

    Full Text Available Hypoxia in solid tumors occurs when metabolic demands in tumor cells surpass the delivery of oxygenated blood. We hypothesize that the 18F-fluorodeoxyglucose (18F-FDG metabolism and tumor blood flow mismatch would correlate with tumor hypoxia.Liver perfusion computed tomography (CT and 18F-FDG positron emission tomography (PET imaging were performed in twelve rabbit livers implanted with VX2 carcinoma. Under CT guidance, a fiber optic probe was inserted into the tumor to measure the partial pressure of oxygen (pO2. Tumor blood flow (BF and standardized uptake value (SUV were measured to calculate flow-metabolism ratio (FMR. Tumor hypoxia was further identified using pimonidazole immunohistochemical staining. Pearson correlation analysis was performed to determine the correlation between the imaging parameters and pO2 and pimonidazole staining.Weak correlations were found between blood volume (BV and pO2 level (r = 0.425, P = 0.004, SUV and pO2 (r = -0.394, P = 0.007, FMR and pimonidazole staining score (r = -0.388, P = 0.031. However, there was stronger correlation between tumor FMR and pO2 level (r = 0.557, P < 0.001.FMR correlated with tumor oxygenation and pimonidazole staining suggesting it may be a potential hypoxic imaging marker in liver tumor.

  1. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  2. A phantom study of tumor contouring on PET imaging

    International Nuclear Information System (INIS)

    Chen Song; Li Xuena; Li Yaming; Yin Yafu; Li Na; Han Chunqi

    2010-01-01

    Objective: To explore an algorithm to define the threshold value for tumor contouring on 18 F-fluorodeoxyglucose (FDG) PET imaging. Methods: A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18 F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value (SUV max ) of each sphere, the SUV of the border of each sphere (SUV border ), the mean SUV of a 1 cm region of background (SUV bg ) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results: The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUV bg /SUV max + 13.9%/D (r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes (GTV) delineated on PET and CT are (7.36±1.62) ml and (8.31±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion: The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT. (authors)

  3. The clinical impact of {sup 18}F-FDG PET/CT in extracranial pediatric germ cell tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Adam; Vali, Reza; Marie, Eman; Shammas, Amer [The Hospital for Sick Children and University of Toronto, Department of Medical Imaging, Nuclear Medicine, Toronto, ON (Canada); Shaikh, Furqan [The Hospital for Sick Children and University of Toronto, Division of Haematology and oncology, Toronto, ON (Canada)

    2017-10-15

    Extracranial germ cell tumors are an uncommon pediatric malignancy with limited information on the clinical impact of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the literature. The purpose of this study was to evaluate and compare the clinical impact on management of {sup 18}F-FDG PET/CT with diagnostic computed tomography (CT) in pediatric extracranial germ cell tumor. The list of {sup 18}F-FDG PET/CT performed for extracranial germ cell tumor between May 2007 and November 2015 was obtained from the nuclear medicine database. {sup 18}F-FDG PET/CT and concurrent diagnostic CT were obtained and independently reviewed. Additionally, the patients' charts were reviewed for duration of follow-up and biopsy when available. The impact of {sup 18}F-FDG PET/CT compared with diagnostic CT on staging and patient management was demonstrated by chart review, imaging findings and follow-up studies. During the study period, 9 children (5 males and 4 females; age range: 1.6-17 years, mode age: 14 years) had 11 {sup 18}F-FDG PET/CT studies for the evaluation of germ cell tumor. Diagnostic CTs were available for comparison in 8 patients (10 {sup 18}F-FDG PET/CT studies). The average interval between diagnostic CT and PET/CT was 7.2 days (range: 0-37 days). In total, five lesions concerning for active malignancy were identified on diagnostic CT while seven were identified on PET/CT. Overall, {sup 18}F-FDG PET/CT resulted in a change in management in 3 of the 9 patients (33%). {sup 18}F-FDG PET/CT had a significant impact on the management of pediatric germ cell tumors in this retrospective study. Continued multicenter studies are required secondary to the rarity of this tumor to demonstrate the benefit of {sup 18}F-FDG PET/CT in particular clinical scenarios. (orig.)

  4. Imaging of benign tumors of the osseous spine

    OpenAIRE

    Riahi, Hend; Mechri, Meriem; Barsaoui, Maher; Bouaziz, Mouna; Vanhoenacker, Filip; Ladeb, Mohamed

    2018-01-01

    Abstract: The purpose of this paper is to present an overview of the imaging features of the most prevalent benign bone tumors involving the spine. Benign tumors of the osseous spine account approximately for 1% of all primary skeletal tumors. Many lesions exhibit characteristic radiologic features. In addition to age and location of the lesion, radiographs are an essential step in the initial detection and characterization but are limited to complex anatomy and superposition. CT and MR imagi...

  5. An analysis of the NMR-CT image by the measurement of proton-relaxation times in tissue

    International Nuclear Information System (INIS)

    Naruse, Shoji; Horikawa, Yoshiharu; Tanaka, Chuzo; Hirakawa, Kimiyoshi; Nishikawa, Hiroyasu; Shimizu, Koji; Kiri, Motosada.

    1984-01-01

    NMR-CT images were analyzed by measuring the proton-relaxation times in tissues. The NMR-CT images were obtained in 10 normal volunteers and 16 patients with brain tumors with a prototype superconducting magnet (Shimadzu Corp., Japan) operating at 0.2 T and 0.375 T. A smooth T 1 relaxation curve was obtained in each part of the brain and the brain tumor by the use of the data of the NMR-CT image; consequently, the in vivo T 1 value was proved to be reliable. The in vivo T 1 value showed the specific value corresponding to each region of the normal brain in all cases. Cerebral gray matter normally had the longest T 1 value, followed by the medulla oblongata, the pons, and white matter. The T 1 value of each region of the brain varied to the same degree in proportion to the strength of the static magnetic field. The in vivo T 1 values of the brain tumor varied with the histological type. All were longer than any part of the brain parenchyma, being between 480 and 780 msec at 0.2 T. The prolongation of the T 1 value does not always correspond to the degree of the malignancy in a tumor. The in vitro T 1 and T 2 values were also prolonged in all tumors. Although the absolute value of T 1 did not coincide between the in vitro and in vivo data, the tendency of the prolongation was the same between them. This result indicated that the NMR-CT images could be analysed by the use of the data of the in vitro T 1 and T 2 values in the tumor tissues. It is important to analyse the NMR-CT image by both in vivo and in vitro examinations of the relaxation times. (J.P.N.)

  6. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    Science.gov (United States)

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  7. A new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy

    International Nuclear Information System (INIS)

    Arrive, Lionel; Azizi, Louisa; Monnier-Cholley, Laurence; Lewin, Maite; Tubiana, Jean-Michel; Rosmorduc, Olivier; Beaussier, Marc

    2006-01-01

    The purpose of this study was to report a new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy. Forty-three hepatocellular carcinomas were not visible with CT fluoroscopy. A 22-gauge Chiba end-hole needle was inserted in the approximate location of a lesion estimated on the basis of anatomical landmarks demonstrated on both previous MR and CT images. We injected 3 ml of a mixture of nonionic contrast material and saline solution. Following the first injection, contrast solution filled the hepatic lesion in 29 of 43 cases. In 8 of 43 cases, contrast solution was distributed in the normal surrounding liver. In 7 of these 8 cases, repositioning allowed us to adjust the needle in the tumor. In the other 6 of 43 cases, contrast solution spread within capsule or pseudocapsule (pattern 3). In all 6 cases, repositioning allowed to adjust the needle in the tumor. This new technique allows an accurate localization of hepatic tumors that are poorly visible with CT fluoroscopy. (orig.)

  8. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  9. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  10. Tumor Localization Using Cone-Beam CT Reduces Setup Margins in Conventionally Fractionated Radiotherapy for Lung Tumors

    International Nuclear Information System (INIS)

    Yeung, Anamaria R.; Li, Jonathan G.; Shi Wenyin; Newlin, Heather E.; Chvetsov, Alexei; Liu, Chihray; Palta, Jatinder R.; Olivier, Kenneth

    2009-01-01

    Purpose: To determine whether setup margins can be reduced using cone-beam computed tomography (CBCT) to localize tumor in conventionally fractionated radiotherapy for lung tumors. Methods and Materials: A total of 22 lung cancer patients were treated with curative intent with conventionally fractionated radiotherapy using daily image guidance with CBCT. Of these, 13 lung cancer patients had sufficient CBCT scans for analysis (389 CBCT scans). The patients underwent treatment simulation in the BodyFix immobilization system using four-dimensional CT to account for respiratory motion. Daily alignment was first done according to skin tattoos, followed by CBCT. All 389 CBCT scans were retrospectively registered to the planning CT scans using automated soft-tissue and bony registration; the resulting couch shifts in three dimensions were recorded. Results: The daily alignment to skin tattoos with no image guidance resulted in systematic (Σ) and random (σ) errors of 3.2-5.6 mm and 2.0-3.5 mm, respectively. The margin required to account for the setup error introduced by aligning to skin tattoos with no image guidance was approximately 1-1.6 cm. The difference in the couch shifts obtained from the bone and soft-tissue registration resulted in systematic (Σ) and random (σ) errors of 1.5-4.1 mm and 1.8-5.3 mm, respectively. The margin required to account for the setup error introduced using bony anatomy as a surrogate for the target, instead of localizing the target itself, was 0.5-1.4 cm. Conclusion: Using daily CBCT soft-tissue registration to localize the tumor in conventionally fractionated radiotherapy reduced the required setup margin by up to approximately 1.5 cm compared with both no image guidance and image guidance using bony anatomy as a surrogate for the target.

  11. The construction of trunk voxel phantom by using CT images and application to 3 dimensional radiotherapy treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. S.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    2001-10-01

    Trunk voxel phantom was constructed by using whole body CT images and tumor doses were calculated by using Monte Carlo method after simulating situation of radiotheraphy treatment planning. The whole body CT images of VHP (Visual Human Project) man were acquired from National Library of Medicine of USA. 153 slices of trunk part were extracted from whole body CT images and MCNP4B, a general purpose Monte Carlo code, was used for dose calculation. Gray scale of CT images were converted into density of medium and processed into trunk voxel phantom ported to MCNP4B input deck. The conversion method was verified by comparing cross sectional images of voxel phantom with original CT images. Tumor volumes with diameter of 3 cm were defined in liver, stomach and right lung and irradiated with 5, 10 and 15 MeV gamma beam with diameter of 6 cm. The technical basis for 3D dose calculation was established through this study for localization of 3D RTP system.

  12. Clinical study of the image fusion between CT and FDG-PET in the head and neck region

    International Nuclear Information System (INIS)

    Shozushima, Masanori; Moriguchi, Hitoshi; Shoji, Satoru; Sakamaki, Kimio; Ishikawa, Yoshihito; Kudo, Keigo; Satoh, Masanobu

    1999-01-01

    Image fusion using PET and CT from the head and neck region was performed with the use of external markers on 7 patients with squamous cell carcinoma. The purpose of this study was to examine a resultant error and the clinical usefulness of image fusion. Patients had primary lesions of the tongue, the maxillary gingiva or the maxillary sinus. All patients underwent PET with FDG and CT to detect tumor sites. Of these 7 patients, diagnostic images and the clinical observation found 6 cases of regional lymph node metastasis of the neck. To ensure the anatomical detail of the PET images, small radioactive markers were placed on the philtrum and below both earlobes. The PET image and CT image were then overlapped on a computer. The image fusion of PET and CT was successfully performed on all patients. The superposition error of this method was examined between the PET and CT images. The accuracy of fit measured as the mean distance between the PET and CT image was in the range of 2-5 mm. PET-CT superimposed images produced an increase in the localization of tumor FDG uptake and localized FDG uptake on the palatine tonsils. The marker system described here for the alignment of PET and CT images can be used on a routine basis without the invasive fixation of external markers, and also improve the management and follow up on patients with head and neck carcinoma. (author)

  13. Computed tomography and magnetic resonance imaging findings of solitary fibrous tumors in the pelvis: Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Zhang Weidong; Chen Jianyu; Cao Yun; Liu Qingyu; Luo Rongguang

    2011-01-01

    Objective: We aimed to analyze the computed tomography (CT) and magnetic resonance imaging (MRI) findings of pelvic solitary fibrous tumors (SFTs) and to improve the diagnostic efficacy for such tumors. Methods: Six cases of pelvic SFTs confirmed by histopathology were analyzed retrospectively. Of the 6 patients, 4 had undergone CT scanning, and 2 had undergone magnetic resonance imaging. All the patients had undergone unenhanced and contrast-enhanced examinations, and 2 had also undergone dynamic CT enhancement examination. Image characteristics such as shape, size, number, edge, attenuation or intensity for each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: All the 6 cases showed oval or rounded and well-defined masses. Unenhanced CT images showed heterogeneous masses with patchy, necrotic foci in 3 cases and homogeneous mass in 1 case. None of the tumors showed calcification. Contrast-enhanced CT images showed marked, heterogeneous enhancement in the first and second cases. Dynamic enhancement scan demonstrated mild homogeneous enhancement in the third case and mild prolonged, delayed enhancement and washout in the fourth case. T1-weighted MR images showed heterogeneous mild hypointense lesion with linear hyperintensity in 1 case, and homogeneous isointensity in the other. T2-weighted images showed heterogeneous mixed intensity in 1 case and mostly hyperintensive lesion with hypointense foci in another case. A case showed marked heterogeneous enhancement and another showed marked homogeneous enhancement on contrast-enhanced T1-weighted images. Conclusion: Radiological findings of pelvic SFTs are variable and nonspecific. However, a well-defined, ovoid or rounded mass with hypointense on MR T2-weighted images and variable enhancement on CT and MR images may suggest the diagnosis of SFTs. Pelvic SFTs should be included in the differential diagnosis of regional tumors.

  14. Ectopic ACTH and CRH co-secreting tumor localized by 68Ga-DOTA-TATE PET/CT

    Science.gov (United States)

    Papadakis, Georgios Z.; Bagci, Ulas; Sadowski, Samira M.; Patronas, Nicholas J.; Stratakis, Constantine A.

    2015-01-01

    Diagnosis of ectopic adrenocorticotropic hormone (ACTH) and corticotropin releasing hormone (CRH) co-secreting tumors causing Cushing syndrome (CS) is challenging, since these tumors are rare and their diagnosis is frequently confused with Cushing disease (CD), due to the effect of CRH on the pituitary. We report a case of a 21-year-old male who was referred to our institution with persistent hypercortisolemia and CS after undergoing unnecessary transsphenoidal surgery (TSS). 68Ga-DOTA-TATE PET/CT revealed increased tracer uptake in the thymus which was histologically proved to be neuroendocrine tumor (NET) staining positive for ACTH and CRH. Imaging with 18F-FDG PET/CT was not diagnostic. PMID:26018709

  15. Variations in tumor size and position due to irregular breathing in 4D-CT: A simulation study

    International Nuclear Information System (INIS)

    Sarker, Joyatee; Chu, Alan; Mui, Kit; Wolfgang, John A.; Hirsch, Ariel E.; Chen, George T. Y.; Sharp, Gregory C.

    2010-01-01

    Purpose: To estimate the position and volume errors in 4D-CT caused by irregular breathing. Methods: A virtual 4D-CT scanner was designed to reproduce axial mode scans with retrospective resorting. This virtual scanner creates an artificial spherical tumor based on the specifications of the user, and recreates images that might be produced by a 4D-CT scanner using a patient breathing waveform. 155 respiratory waveforms of patients were used to test the variability of 4D-CT scans. Each breathing waveform was normalized and scaled to 1, 2, and 3 cm peak-to-peak motion, and artificial tumors with 2 and 4 cm radius were simulated for each scaled waveform. The center of mass and volume of resorted 4D-CT images were calculated and compared to the expected values of center of mass and volume for the artificial tumor. Intrasubject variability was investigated by running the virtual scanner over different subintervals of each patient's breathing waveform. Results: The average error in the center of mass location of an artificial tumor was less than 2 mm standard deviation for 2 cm motion. The corresponding average error in volume was less than 4%. In the worst-case scenarios, a center of mass error of 1.0 cm standard deviation and volume errors of 30%-60% at inhale were found. Systematic errors were observed in a subset of patients due to irregular breathing, and these errors were more pronounced when the tumor volume is smaller. Conclusions: Irregular breathing during 4D-CT simulation causes systematic errors in volume and center of mass measurements. These errors are small but depend on the tumor size, motion amplitude, and degree of breathing irregularity.

  16. Diagnosis of tumors of the pituitary region by two-plane CT scans

    International Nuclear Information System (INIS)

    Murata, Minoru; Inoue, Hiroshi; Misumi, Shuzo; Shimizu, Tsuneo; Tamura, Masaru

    1981-01-01

    Thirty five cases of tumors in the pituitary region were analysed by two-plane CT (ordinary sections and reverse sections) in order to obtain a more accurate image of the tumor and thus establish an appropriate indication for the subnasal transsphenoidal approach. The tumors of pituitary region were classified into six groups (types I-VI) according to their degree of extension and direction of growth. Small tumors such as types I and II were detected more clearly by the reverse section than by the ordinary section. In cases of large tumors (types III-VI) relation of the tumor to the surrounding structures such as the sphenoid sinus, third ventricle, lateral ventricule, middle fossa and brain stem was accurately demonstrated by the reverse section. In the differential diagnosis of tumors in the pituitary regions, tumors showing mixed density or slightly high density and widening of the anteroposterior diameter of the sella in the precontrast reverse section and homogeneous enhancement by infusion were likely to be pituitary adenomas. One third of the pituitary adenomas showed ring-like high density in the post-contrast reverse section. Calcification was not seen in the pituitary adenomas by CT scans. All craniopharyngiomas belonged to types III-VI. Craniopharyngiomas showed high and/or low density, and various degrees of calcification in plain CT scans. Ring-like high density was seen in two thirds of the craniopharyngiomas. About one third of the craniopharyngiomas showed widening of the antero-posterior diameter of the sella. (J.P.N.)

  17. Radiological image interpretation for hematoma and small tumors simulated in a head and neck phantom

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio Passos Ribeiro

    2009-01-01

    Subarachnoidal hemorrhages (HSA) are caused by aneurysms and their symptom usually becomes evident after a rupture. Nevertheless, there are situations in which the aneurysms compress a nerve or produce a bleed before the rupture happens, as consequence one alert signal like headache occurs. It, often occurs after minutes or weeks previous the major rupture. The main goal is to prevent a massive hemorrhage. Thus the Computer Tomography (CT) scan of skull provides a basic and specific function: to reveal the position where the hemorrhage was produced, guiding to a additional medical procedures. On the other hand, CT does not prevent the cerebral tumor development, but precise diagnostic for some symptoms such as vomits, nauseas, epileptic attacks, weakness in arms or legs, require this image protocol. CT has its fundamental importance to tumor detection. Indeed CT reveals its importance in the tumor early diagnosis. Specialized training in CT analysis shall be done. Ahead of a precise diagnosis to manager an early intervention, a CT diagnostic training is suitable for a favorable prognostic. In this context, focusing on propose of radiological inquires; a head and neck phantom will be used to simulate hematomas and cerebral tumors. Images of CT of skull will be used to identify these lesions physically implanted in phantom. The radiological response will be analyzed with the purpose of validation of the skull's CT diagnosis, for a double blind test. The diagnostic with non contrast CT shows only higher 5mm diameter subjects (tumors) identified by the double blind test. Hemorrhage is identified by only the administrator (single-blind test). As conclusion, the author's launches the hypothesis that this object simulator shall provide assistance for specialized training on pathology interpretation on radiological images. (author)

  18. Rapid ex vivo imaging of PAIII prostate to bone tumor with SWIFT-MRI.

    Science.gov (United States)

    Luhach, Ihor; Idiyatullin, Djaudat; Lynch, Conor C; Corum, Curt; Martinez, Gary V; Garwood, Michael; Gillies, Robert J

    2014-09-01

    The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. SWIFT images with nominal resolution of 78 μm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed. Copyright © 2013 Wiley Periodicals, Inc.

  19. Quantitative CT analysis for the preoperative prediction of pathologic grade in pancreatic neuroendocrine tumors

    Science.gov (United States)

    Chakraborty, Jayasree; Pulvirenti, Alessandra; Yamashita, Rikiya; Midya, Abhishek; Gönen, Mithat; Klimstra, David S.; Reidy, Diane L.; Allen, Peter J.; Do, Richard K. G.; Simpson, Amber L.

    2018-02-01

    Pancreatic neuroendocrine tumors (PanNETs) account for approximately 5% of all pancreatic tumors, affecting one individual per million each year.1 PanNETs are difficult to treat due to biological variability from benign to highly malignant, indolent to very aggressive. The World Health Organization classifies PanNETs into three categories based on cell proliferative rate, usually detected using the Ki67 index and cell morphology: low-grade (G1), intermediate-grade (G2) and high-grade (G3) tumors. Knowledge of grade prior to treatment would select patients for optimal therapy: G1/G2 tumors respond well to somatostatin analogs and targeted or cytotoxic drugs whereas G3 tumors would be targeted with platinum or alkylating agents.2, 3 Grade assessment is based on the pathologic examination of the surgical specimen, biopsy or ne-needle aspiration; however, heterogeneity in the proliferative index can lead to sampling errors.4 Based on studies relating qualitatively assessed shape and enhancement characteristics on CT imaging to tumor grade in PanNET,5 we propose objective classification of PanNET grade with quantitative analysis of CT images. Fifty-five patients were included in our retrospective analysis. A pathologist graded the tumors. Texture and shape-based features were extracted from CT. Random forest and naive Bayes classifiers were compared for the classification of G1/G2 and G3 PanNETs. The best area under the receiver operating characteristic curve (AUC) of 0:74 and accuracy of 71:64% was achieved with texture features. The shape-based features achieved an AUC of 0:70 and accuracy of 78:73%.

  20. [Value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma after TACE treatment].

    Science.gov (United States)

    Xing, Gusheng; Wang, Shuang; Li, Chenrui; Zhao, Xinming; Zhou, Chunwu

    2015-03-01

    To investigate the value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma (HCC) after transcatheter arterial chemoebolization (TACE). Consecutive 32 HCC patients with previous TACE treatment were included in this study. For the follow-up, arterial phase (AP) and venous phase (VP) dual-phase CT scans were performed with a single-source dual-energy CT scanner (Discovery CT 750HD, GE Healthcare). Iodine concentrations were derived from iodine-based material-decomposition images in the liver parenchyma, tumors and coagulation necrosis (CN) areas. The iodine concentration difference (ICD) between the arterial-phase (AP) and venal-phase (VP) were quantitatively evaluated in different tissues.The lesion-to-normal parenchyma iodine concentration ratio (LNR) was calculated. ROC analysis was performed for the qualitative evaluation, and the area under ROC (Az) was calculated to represent the diagnostic ability of ICD and LNR. In all the 32 HCC patients, the region of interesting (ROI) for iodine concentrations included liver parenchyma (n=42), tumors (n=28) and coagulation necrosis (n=24). During the AP the iodine concentration of CNs (median value 0.088 µg/mm(3)) appeared significantly higher than that of the tumors (0.064 µg/mm(3), P=0.022) and liver parenchyma (0.048 µg/mm(3), P=0.005). But it showed no significant difference between liver parenchyma and tumors (P=0.454). During the VP the iodine concentration in hepatic parenchyma (median value 0.181 µg/mm(3)) was significantly higher than that in CNs (0.140 µg/mm(3), P=0.042). There was no significant difference between liver parenchyma and tumors, CNs and tumors (both P>0.05). The median value of ICD in CNs was 0.006 µg/mm(3), significantly lower than that of the HCC (0.201 µg/mm(3), Piodine-based material decomposition images with gemstone spectral CT imaging can improve the diagnostic efficacy of CT imaging

  1. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    International Nuclear Information System (INIS)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso; Kuruoshi, Marcia Etsuko

    2009-01-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  2. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  3. An evaluation of the variability of tumor-shape definition derived by experienced observers from CT images of supraglottic carcinomas (ACRIN protocol 6658)

    International Nuclear Information System (INIS)

    Cooper, Jay S.; Mukherji, Suresh K.; Toledano, Alicia Y.; Beldon, Clifford; Schmalfuss, Ilona M.; Amdur, Robert; Sailer, Scott; Loevner, Laurie A.; Kousouboris, Phil; Ang, K. Kian; Cormack, Jean; Sicks, JoRean M.S.

    2007-01-01

    Purpose: Accurate target definition is considered essential for sophisticated, image-guided radiation therapy; however, relatively little information has been reported that measures our ability to identify the precise shape of targets accurately. We decided to assess the manner in which eight 'experts' interpreted the size and shape of tumors based on 'real-life' contrast-enhanced computed tomographic (CT) scans. Methods and Materials: Four neuroradiologists and four radiation oncologists (the authors) with considerable experience and presumed expertise in treating head-and-neck tumors independently contoured, slice-by-slice, his/her interpretation of the precise gross tumor volume (GTV) on each of 20 sets of CT scans taken from 20 patients who previously were enrolled in Radiation Therapy Oncology Group protocol 91-11. Results: The average proportion of overlap (i.e., the degree of agreement) was 0.532 (95% confidence interval 0.457 to 0.606). There was a slight tendency for the proportion of overlap to increase with increasing average GTV. Conclusions: Our work suggests that estimation of tumor shape currently is imprecise, even for experienced physicians. In consequence, there appears to be a practical limit to the current trend of smaller fields and tighter margins

  4. Pancreatic gross tumor volume contouring on computed tomography (CT) compared with magnetic resonance imaging (MRI): Results of an international contouring conference.

    Science.gov (United States)

    Hall, William A; Heerkens, Hanne D; Paulson, Eric S; Meijer, Gert J; Kotte, Alexis N; Knechtges, Paul; Parikh, Parag J; Bassetti, Michael F; Lee, Percy; Aitken, Katharine L; Palta, Manisha; Myrehaug, Sten; Koay, Eugene J; Portelance, Lorraine; Ben-Josef, Edgar; Erickson, Beth A

    Accurate identification of the gross tumor volume (GTV) in pancreatic adenocarcinoma is challenging. We sought to understand differences in GTV delineation using pancreatic computed tomography (CT) compared with magnetic resonance imaging (MRI). Twelve attending radiation oncologists were convened for an international contouring symposium. All participants had a clinical and research interest in pancreatic adenocarcinoma. CT and MRI scans from 3 pancreatic cases were used for contouring. CT and MRI GTVs were analyzed and compared. Interobserver variability was compared using Dice's similarity coefficient (DSC), Hausdorff distances, and Jaccard indices. Mann-Whitney tests were used to check for significant differences. Consensus contours on CT and MRI scans and constructed count maps were used to visualize the agreement. Agreement regarding the optimal method to determine GTV definition using MRI was reached. Six contour sets (3 from CT and 3 from MRI) were obtained and compared for each observer, totaling 72 contour sets. The mean volume of contours on CT was significantly larger at 57.48 mL compared with a mean of 45.76 mL on MRI, P = .011. The standard deviation obtained from the CT contours was significantly larger than the standard deviation from the MRI contours (P = .027). The mean DSC was 0.73 for the CT and 0.72 for the MRI (P = .889). The conformity index measurement was similar for CT and MRI (P = .58). Count maps were created to highlight differences in the contours from CT and MRI. Using MRI as a primary image set to define a pancreatic adenocarcinoma GTV resulted in smaller contours compared with CT. No differences in DSC or the conformity index were seen between MRI and CT. A stepwise method is recommended as an approach to contour a pancreatic GTV using MRI. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  5. Diagnosis of pelvic wall tumor on multislice CT

    International Nuclear Information System (INIS)

    Zhang Keyun; Deng Lequn; Lei Hongwei

    2011-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) in diagnosing pelvic wall tumors. Methods: MSCT of 21 cases of pelvic wall tumors including metastasis (10), neurogenic tumor (5), chondrosarcoma (2), chordoma (1), aneurysmal bone cyst (1), giant cell tumor (1), and osteochondroma (1) was retrospectively analyzed. Results: CT appearances of pelvic wall tumors include bony destruction and soft tissue masses. Common features were bone destruction in metastasis, expansion of the neuroforamen in neurogenic tumor, pleomorphic calcification in chondrosarcoma, lower sacral vertebral location of chordoma, iliac crest bone destruction in giant cell tumor, cauliflower-like nodules in osteochondroma. Conclusion: MSCT with three-dimensional volume rendering demonstrates well the tumor shape, size, extent, internal structure and relationship with the surrounding organs to aid diagnosis of pelvic wall tumors. (authors)

  6. Benign fatty tumors: classification, clinical course, imaging appearance, and treatment

    International Nuclear Information System (INIS)

    Bancroft, Laura W.; Kransdorf, Mark J.; Peterson, Jeffrey J.; O'Connor, Mary I.

    2006-01-01

    Lipoma is the most common soft-tissue tumor, with a wide spectrum of clinical presentations and imaging appearances. Several subtypes are described, ranging from lesions entirely composed of mature adipose tissue to tumors intimately associated with nonadipose tissue, to those composed of brown fat. The imaging appearance of these fatty masses is frequently sufficiently characteristic to allow a specific diagnosis. However, in other cases, although a specific diagnosis is not achievable, a meaningful limited differential diagnosis can be established. The purpose of this manuscript is to review the spectrum of benign fatty tumors highlighting the current classification system, clinical presentation and behavior, spectrum of imaging appearances, and treatment. The imaging review emphasizes computed tomography (CT) scanning and magnetic resonance (MR) imaging, differentiating radiologic features. (orig.)

  7. 110 Subfascial lipomatous tumors. MR and CT findings versus histopathological diagnosis and cytogenetic analysis

    International Nuclear Information System (INIS)

    Einarsdottir, H.; Soederlund, V.; Larsson, O.; Mandahl, N.; Bauer, H.C.F.

    1999-01-01

    Purpose: To evaluate whether liposarcoma, atypical lipomatous tumors and lipoma can be differentiated radiologically. Material and Methods: We have retrospectively analyzed CT and/or MR images of 110 subfascial lipomatous lesions. The amount of fat within the tumors was visually graded from the images as: none, 1-75%, 75-95% or 95-100%. The structure of non-fatty tumor components was compared. The images were compared to histopathology and in 37 cases to cytogenetic findings. Results: Only 4 of 20 liposarcomas contained fat. All 4 lesions, histopathologically diagnosed as atypical lipomatous tumors, contained fat but less than 75% of tumor volume. All lesions with more fat than 75% of tumor volume were histologically diagnosed as lipomas. However, one-third of the karyotyped lipomas had ring chromosomes which are considered typical for atypical lipomatous tumors. Conclusion: When a tumor is composed more or less solely of fat, the diagnosis of a lipoma or atypical lipomatous tumor with a phenotype simulating a lipoma can be assumed. When the fat content is less than 75% of the tumor volume or non-fatty nodules are found, biopsies from different tumor components have to be performed to exclude malignancy. When no fat is found, imaging does not help in differentiating lipoma or liposarcoma from other soft tissue tumors. (orig.)

  8. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  9. The diagnosis of intracranial tumors by CT (computerized tomography) from a practical point of view

    International Nuclear Information System (INIS)

    Elke, M.; Wiggli, U.; Huenig, R.

    1977-01-01

    In a historical abstract the mathematical basis of image reconstruction techniques and CT is reviewed. The enhancement of iodine contrast media is essential in CT diagnostis of space occupying intracranial lesions. Intracranial tumors usually show relatively characteristical but mostly non-specific absorption patterns. Additional clinical information is necessary for differential diagnostic evalution. The development of tables with various tumor patterns is recommended. Absorption feature of primary and secondary brain-tumors with the surrounding edema is explained. Glioblastomas as well as metastases often show a distinct cerebral edema which has been observed in 64% of our patients with metastases and distinctly localized high dense foci in 69%. 6,000 patients were investigated by CT and 1,708 examinations were performed with contrast enhancement. Side-effects are within the known reaction of other intravenously applicated contrast media. (orig.) [de

  10. Arterial displacement by the tumor demonstrated by magnetic resonance CT

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Yoshikawa, Kohki; Machida, Tohru; Iio, Masahiro.

    1985-01-01

    MR-CT permits visualization of blood vessels non-invasively. Major blood vessels in scan slices are demonstrated as structures with low or no signal intensity. In this report, two cases with brain tumor and spinal tumor are presented in which arterial displacement by the tumor was visualized by MR-CT. MR-CT is considered to be an effective method in detecting blood vessel abnormalities. (author)

  11. MRI and CT findings of the giant cell tumors of the skull; five cases and a review of the literature

    International Nuclear Information System (INIS)

    Kashiwagi, Nobuo; Hirabuki, Norio; Andou, Kumiko; Yoshifumi, Narumi; Tanaka, Hisashi; Morino, Hideo; Taki, Takuyu; Ishikura, Reiichi; Hirota, Seiichi; Onishi, Hiromitu; Nakamura, Hironobu

    2006-01-01

    Purpose: To investigate CT and MR findings of giant cell tumors (GCTs) of the skull, an unusual site for such tumors. Materials and methods: CT and MR features of five histologically proven giant cell tumors of the skull were retrospectively reviewed. We also reviewed 22 cases in the literature that included MR or CT findings. Results: Three of the tumors originated from the temporal bone with predominantly medial extension, and the other two were centered in the body of the sphenoid bone and featured symmetrical soft tissue extension. CT images with bone window settings showed reactive bone changes for all three tumors of the temporal bone, suggesting slow growth for example, an expanded intradiploic space, expansive remodelling and development of foci of pressure erosion. GCTs of the sphenoid bone showed purely osteolytic changes without remodelling. Although the MR signals and enhancement patterns varied, all the tumors of the temporal bone had a markedly low intensity area on T2-weighted images, which was not seen in the tumors of the sphenoid bone. The findings for our cases generally corresponded to those reported in the literature. Conclusion: Giant cell tumors of the skull have two preferential sites and may have characteristic tendencies as to their extent. Bone changes and MR signals appear to show differences between the two sites

  12. SU-E-P-41: Imaging Coordination of Cone Beam CT, On-Board Image Conjunction with Optical Image Guidance for SBRT Treatment with Respiratory Motion Management

    International Nuclear Information System (INIS)

    Liu, Y; Campbell, J

    2015-01-01

    Purpose: To spare normal tissue for SBRT lung/liver patients, especially for patients with significant tumor motion, image guided respiratory motion management has been widely implemented in clinical practice. The purpose of this study was to evaluate imaging coordination of cone beam CT, on-board X-ray image conjunction with optical image guidance for SBRT treatment with motion management. Methods: Currently in our clinic a Varian Novlis Tx was utilized for treating SBRT patients implementing CBCT. A BrainLAB X-ray ExacTrac imaging system in conjunction with optical guidance was primarily used for SRS patients. CBCT and X-ray imaging system were independently calibrated with 1.0 mm tolerance. For SBRT lung/liver patients, the magnitude of tumor motion was measured based-on 4DCT and the measurement was analyzed to determine if patients would be beneficial with respiratory motion management. For patients eligible for motion management, an additional CT with breath holding would be scanned and used as primary planning CT and as reference images for Cone beam CT. During the SBRT treatment, a CBCT with pause and continuing technology would be performed with patients holding breath, which may require 3–4 partially scanned CBCT to combine as a whole CBCT depending on how long patients capable of holding breath. After patients being setup by CBCT images, the ExactTrac X-ray imaging system was implemented with patients’ on-board X-ray images compared to breath holding CT-based DRR. Results: For breath holding patients SBRT treatment, after initially localizing patients with CBCT, we then position patients with ExacTrac X-ray and optical imaging system. The observed deviations of real-time optical guided position average at 3.0, 2.5 and 1.5 mm in longitudinal, vertical and lateral respectively based on 35 treatments. Conclusion: The respiratory motion management clinical practice improved our physician confidence level to give tighter tumor margin for sparing normal

  13. Imaging analysis of colonic villous tumors

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Lim, Joo Won; Lee, Dong Ho; Ko, Yung Tae; Yang, Ik

    1996-01-01

    To evaluate the CT and US features of the colonic villous tumors. We retrospectively reviewed the CT findings of 11 cases with histologically proved colonic villous tumor. CT parameters evaluated were morphological appearances and enhancing pattern (size, shape, margin, presence or absence of fronds, bowel wall thickening). CT features of six cases with malignant change were compared with five tumors without malignant change. US features available in 10 patients were also analyzed. On CT, the tumors showed irregular margin(n=9), presence of fronds(n=6), lobulated shape(n=11), with pericolonic invasion(n=1). Six cases with malignant change were larger(mean, 6.8 cm in diameter) than those without malignant change(mean, 3.3cm). US features in 10 cases were intraluminal mass(n=5), colonic wall thickening(n=5), with variable echogenicity. Colonic villous tumor appeared as a nonspecific mass on CT and US with a difficulty in distinguishing from colon carcinoma

  14. Imaging benign pathology and variants with uptake in 68ga-Dotatate PET/CT studies

    International Nuclear Information System (INIS)

    Servente, L.; Bianco, C.; Gigirey, V.; Alonso, O.

    2017-01-01

    Purpose: To evaluate the physiological, anatomical variants and benign lesions in positron emission computed tomography (PET/CT) studies with 68Ga-DOTATATE.Materials and methods: We retrospectively reviewed PET/CT reports scanned with 68Ga-DOTATATE and selected those that contained words in the report related to anatomical, physiological variants and benign tumors. The degree of 68Ga-DOTATATE uptake was evaluated qualitatively and quantitatively by measuring the standarized uptake max value (SUVmax value). The anatomical location, SUVmax value and morphological CT image findings were recorded. All cases had clinical and imaging follow-up. Results: From a total of 772 PET/CT reports, 28 patients were obtained with 33 benign variants or tumors, 14 females and 14 males with a median age of 63 years. Uptake patterns were classified into four groups: anatomic and physiological variants (15), dependent on osteoblastic activity (4), dependent on inflammatory activity (10) and non-neuro-endocrine benign tumors (4).Discussion: Somatostatin receptors are overexpressed not only in the neuroendocrine system but also in other tissues. Physiological, anatomical variants and benign tumors expressing these receptors may be misleading. In the present work the frequency of this finding is 5.1%.Conclusion: Physiological variants and benign lesions (tumor and inflammatory) can accumulate 68Ga-DOTATATE since their tissues can express somatostatin receptors. The semiologic analysis of the tomographic component of this hybrid method enhances the diagnostic efficacy, optimizing PET/CT study performance. (authors) [es

  15. CT diagnosis of hyperdense intracranial neoplasms. Review of the literature

    International Nuclear Information System (INIS)

    Ishikura, Reiichi; Ando, Kumiko; Tominaga, Satoru; Nakao, Norio; Ikeda, Jouta; Takemura, Yuriko; Morikawa, Tsutomu

    1999-01-01

    In contrast to typical astrocytic tumors that show hypodense areas on computed tomographic images, some intracranial tumors show hyperdense areas on CT images. The major reasons for hyperdensity on CT images are hypercellular lesions, intratumoral calcification, and intratumoral hemorrhage. Malignant lymphomas, germinomas, and medulloblastomas show homogenous hyperdensity on CT images because of their hypercellularity. Tumorous lesions such as subependymal giant cell astrocytomas, oligodendrogliomas, ependymomas, central neurocytomas, craniopharyngiomas, and meningiomas often present with hyperdense calcified lesions on CT images. Intratumoral hemorrhage also causes hyperdensity on CT images, and is often associated with metastatic brain tumors, glioblastomas, pituitary adenomas, and rarely with any of the other intracranial tumors. Although magnetic resonance imaging is now the major diagnostic tool for diseases of the central nervous system, the first imaging studies for patients with neurologic symptoms are still CT scans. Hyperdense areas on CT images are a clue to making an accurate diagnosis of intracranial neoplasms. (author)

  16. In vivo tomographic imaging of lung colonization of tumour in mouse with simultaneous fluorescence and X-ray CT.

    Science.gov (United States)

    Zhang, Bin; Gao, Fuping; Wang, Mengjiao; Cao, Xu; Liu, Fei; Wang, Xin; Luo, Jianwen; Wang, Guangzhi; Bai, Jing

    2014-01-01

    Non-invasive in vivo imaging of diffuse and wide-spread colonization within the lungs, rather than distinct solid primary tumors, is still a challenging work. In this work, a lung colonization mouse model bearing A549 human lung tumor was simultaneously scanned by a dual-modality fluorescence molecular tomography (FMT) and X-ray computed tomography (CT) system in vivo. A two steps method which incorporates CT structural information into the FMT reconstruction procedure is employed to provide concurrent anatomical and functional information. By using the target-specific fluorescence agent, the fluorescence tomographic results show elevated fluorescence intensity deep within the lungs which is colonized with diffuse and wide-spread tumors. The results were confirmed with ex vivo fluorescence reflectance imaging and histological examination of the lung tissues. With FMT reconstruction combined with the CT information, the dual-modality FMT/micro-CT system is expected to offer sensitive and noninvasive imaging of diffuse tumor colonization within the lungs in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Liver tumors, correlation of computed tomography (CT) and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1984-09-01

    Computed tomographic and pathologic correlation was studied in 12 autopsied cases with 11 cases of metastatic liver tumors and 1 case of hepatocellular carcinoma. Despite of proliferative patterns of the tumors, nodular low attenuations on CT showed scattered nodular lesions and geographic low attenuations on CT showed groups of multiple small nodular lesions, macroscopically. Abnormal areas of low attenuation were generally diminished by drip infusion contrast enhancement, which was more significant on tumors of infiltrative proliferation. Tumors of infiltrative proliferation revealed little degeneration of surrounding liver cells and abnormal areas of low attenuation were more distinct before contrast enhancement. Tumors of expansive proliferation revealed obvious degeneration of surrounding liver cells and a case having about 200 layers of degenerated liver cells revealed more distinct after contrast enhancement. The central lower density areas in abnormal areas of low attenuation on CT coincided with liquefactive necroses with scanty capillary. vessels and fibrotic changes, histopathologically. But coagulative necroses without decrease of surrouding blood flows were not visualized on CT. CT could not demonstrate the liquefactive necroses in more small nodules than 2 cm in diameter. (J.P.N.).

  18. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Y. X.; Van Reeth, E.; Poh, C. L., E-mail: clpoh@ntu.edu.sg [School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637459 (Singapore); Teo, S.-K. [Institute of High Performance Computing, Agency for Science, Technology and Research, Singapore 138632 (Singapore); Tan, C. H. [Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore 308433 (Singapore); Tham, I. W. K. [Department of Radiation Oncology, National University Cancer Institute, Singapore 119082 (Singapore)

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  19. CT and MR imaging of high cervical intradural lipomas

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joo Hyeong; Choi, Woo Suk; Lee, Sun Wha; Lim, Jae Hoon; Leem, Woon; Kim, Gook Ki; Rhee, Bong Arm [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1988-04-15

    Intradural spinal lipoma occurs in less than 1% of all spinal cord tumors. It has been described at every level of the spinal canal, although its most common location is the cervicothoracic and thoracic region. However, lipoma located in the high cervical region is very unusual. We described two cases, a teenager and an adult, with progressive neurologic deficit from such a lipomatous tumor, which were evaluated by CT scanning and MR imaging.

  20. Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

    International Nuclear Information System (INIS)

    Yu Jinming; Li Xinke; Xing Ligang; Mu Dianbin; Fu Zheng; Sun Xiaorong; Sun Xiangyu; Yang Guoren; Zhang Baijiang; Sun Xindong; Ling, C. Clifton

    2009-01-01

    Purpose: To determine the cut-off standardized uptake value (SUV) on 18 F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV path ) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-μm sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV path determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV PET , was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV PET was the same as the GTV path . Results: The fixation process induced a volumetric reduction to 82% ± 10% (range, 62-100%) of the original. The maximal SUV was 10.1 ± 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% ± 11% and 3.0 ± 1.6, respectively. The optimal threshold was inversely correlated with GTV path and tumor diameter (p path or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV path as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

  1. The validity and findings of superselective angio-CT of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tomura, Noriaki; Kusaka, Kazuya; Kato, Koki; Sato, Kimihiko; Watarai, Jiro; Sasajima, Hiroyasu; Kowada, Masayoshi [Akita Univ. (Japan). School of Medicine; Hatayama, Takashi

    1995-09-01

    Superselective angio-CT (SSA-CT) was performed on 12 patients with malignant astrocytomas who had been treated with superselective intra-arterial infusions of ACNU. SSA-CT was done at the time of super-selective intra-arterial infusion. Following conventional intra-arterial DSA for which a 6-F catheter was used, a microcatheter (Tracker-18) was passed coaxially inside the guiding catheter, and advanced into the feeding arteries of the tumor. After the microcatheter was placed in the proper position, a dynamic CT was performed with contrast administration into the feeding arteries. A GE CT/T 9800 scanner was used; the contrast medium was iopamidol which was administered diluted with 5 volumes of saline. There was representation of tumor stains by SSA-CT in all 12 patients, and of the medullary veins in three. In contrast, DSA or conventional enhanced CT represented tumor stain/enhancement in only 10 patients, and the medullary veins in one. In two patients who had no contrast tumor enhancement on the CT with contrast, SSA-CT could represent tumor stain. SSA-CT was also superior to DSA and conventional CT for the visualization of medullary veins The feeding artery in a patient with a posterior frontal astrocytoma was unclear on DSA. However, SSA-CT with contrast administration in the anterior cerebral artery revealed tumor stain; this modality was also useful for identifying the artery to be used for ACNU infusion. In another patient with a tumor in the parahippocampal gyrus, SSA-CT with contrast administration in the posterior cerebral artery could provide the proper position of the catheter for the infusion of ACNU. None of the patients experienced complications due to catheterization nor any systemic side-effects. (H.O.).

  2. Splenosis Mimicking Relapse of a Neuroendocrine Tumor at Gallium-68-DOTATOC PET/CT

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Luca, Giovanella; Barbara, Muoio; Carmelo, Caldarella

    2014-01-01

    A 48-year-old female patient underwent splenopancreasectomy for a 4-cm pancreatic neuroendocrine tumor (pNET), grade G2, located in the pancreatic tail. One year after surgery, the patient presented an increased serum level of the tumor marker chromogranin A (value: 160 U/l). Therefore, she underwent somatostatin receptor PET/CT using gallium-68-DOTATOC for restaging. This imaging method showed a focal area of increased radiopharmaceutical uptake corresponding to a 2.5-cm nodule located in the left superior abdomen near a clip from the previous surgery, suggesting a possible relapse of pNET. Based on this PET/CT finding, the patient underwent ultrasonography-guided core biopsy of this nodule. Histology did not reveal findings suggestive of pNET but identified spleen tissue most likely caused by splenosis accidentally seeded at the previous operation. It is likely that the increased serum level of the tumor marker chromogranin A was due to the chronic proton-pump inhibitors use. Somatostatin receptor PET/CT is an accurate imaging method for staging and restaging pNET, presenting high sensitivity and specificity in this setting. Nevertheless, possible sources of false-negative and -positive findings with this method should be taken into account. Inflammatory lesions represent the most frequent causes of false-positive findings for pNET at somatostatin receptor imaging because inflammatory cellsmay overexpress somatostatin receptors on their cell surface. In our case, we showed that splenosis may represent a possible cause of false-positive findings for pNET relapse due to the physiological uptake of somatostatin analogs by the spleen tissue

  3. A tri-modality image fusion method for target delineation of brain tumors in radiotherapy.

    Directory of Open Access Journals (Sweden)

    Lu Guo

    Full Text Available To develop a tri-modality image fusion method for better target delineation in image-guided radiotherapy for patients with brain tumors.A new method of tri-modality image fusion was developed, which can fuse and display all image sets in one panel and one operation. And a feasibility study in gross tumor volume (GTV delineation using data from three patients with brain tumors was conducted, which included images of simulation CT, MRI, and 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET examinations before radiotherapy. Tri-modality image fusion was implemented after image registrations of CT+PET and CT+MRI, and the transparency weight of each modality could be adjusted and set by users. Three radiation oncologists delineated GTVs for all patients using dual-modality (MRI/CT and tri-modality (MRI/CT/PET image fusion respectively. Inter-observer variation was assessed by the coefficient of variation (COV, the average distance between surface and centroid (ADSC, and the local standard deviation (SDlocal. Analysis of COV was also performed to evaluate intra-observer volume variation.The inter-observer variation analysis showed that, the mean COV was 0.14(± 0.09 and 0.07(± 0.01 for dual-modality and tri-modality respectively; the standard deviation of ADSC was significantly reduced (p<0.05 with tri-modality; SDlocal averaged over median GTV surface was reduced in patient 2 (from 0.57 cm to 0.39 cm and patient 3 (from 0.42 cm to 0.36 cm with the new method. The intra-observer volume variation was also significantly reduced (p = 0.00 with the tri-modality method as compared with using the dual-modality method.With the new tri-modality image fusion method smaller inter- and intra-observer variation in GTV definition for the brain tumors can be achieved, which improves the consistency and accuracy for target delineation in individualized radiotherapy.

  4. Radiation therapy treatment planning: CT, MR imaging and three-dimensional planning

    International Nuclear Information System (INIS)

    Lichter, A.S.

    1987-01-01

    The accuracy and sophistication of radiation therapy treatment planning have increased rapidly in the last decade. Currently, CT-based treatment planning is standard throughout the country. Care must be taken when CT is used for treatment planning because of clear differences between diagnostic scans and scans intended for therapeutic management. The use of CT in radiation therapy planning is discussed and illustrated. MR imaging adds another dimension to treatment planning. The ability to use MR imaging directly in treatment planning involves an additional complex set of capabilities from a treatment planning system. The ability to unwarp the geometrically distorted MR image is a first step. Three-dimensional dose calculations are important to display the dose on sagittal and acoronal sections. The ability to integrate the MR and CT images into a unified radiographic image is critical. CT and MR images are two-dimensional representations of a three-dimensional problem. Through sophisticated computer graphics techniques, radiation therapists are now able to integrate a three-dimensional image of the patient into the treatment planning process. This allows the use of noncoplanar treatment plans and a detailed analysis of tumor and normal tissue anatomy; it is the first step toward a fully conformational treatment planning system. These concepts are illustrated and future research goals outlined

  5. Ga-68-DOTA-TATE PET/CT for discrimination of tumors of the optic pathway.

    Science.gov (United States)

    Klingenstein, Annemarie; Haug, Alexander R; Miller, Christina; Hintschich, Christoph

    2015-02-01

    Symptomatic tumors of the optic nerve pathway may endanger vision. They are difficult to classify by imaging alone and biopsy may damage visual function. Tumor pathology influences treatment decision and a diagnostic tool with a high sensitivity and specificity would therefore be invaluable. We hypothesized that Ga-68-DOTA-TATE PET/CT may help in discriminating optic nerve tumors as uptake of somatostatin is elevated in meningiomas. Ga-68-DOTA-TATE PET/CT was used to examine 13 patients with ambiguous, symptomatic lesions of the optic pathway for treatment planning. The presence or absence of meningioma was validated by histopathology or supplementary diagnostic work-up. Ga-68-DOTA-TATE PET/CT identified 10 meningiomas (en plaque = 1, optic nerve sheath = 4, sphenoidal = 5) correctly via increased SSTR (somatostatin receptor) expression (mean SUVmax (maximum standardized uptake value) = 14.3 ± 15.4). 3 tumors did not show elevated Ga-68-DOTA-TATE uptake (SUVmax = 2.1 ± 1.0). Subsumizing all clinical-radiological follow-up tools available, these lesions were classified as an intracerebral metastasis of an advanced gastric carcinoma, histologically proven inflammatory collagenous connective tissue and presumed leukemic infiltration of a newly diagnosed chronic lymphocytic leukemia. In this case series, Ga-68-DOTA-TATE PET/CT demonstrated both a sensitivity and specificity of 100%. Yet, the golden standard of histopathology was only available in a subset of patients included. Ga-68-DOTA-TATE PET/CT proved to be a valuable diagnostic tool for the correct classification of equivocal, symptomatic tumors of the anterior optic pathway requiring therapy. PET/CT results influenced therapy decision essentially in all cases.

  6. Robust augmented reality registration method for localization of solid organs' tumors using CT-derived virtual biomechanical model and fluorescent fiducials.

    Science.gov (United States)

    Kong, Seong-Ho; Haouchine, Nazim; Soares, Renato; Klymchenko, Andrey; Andreiuk, Bohdan; Marques, Bruno; Shabat, Galyna; Piechaud, Thierry; Diana, Michele; Cotin, Stéphane; Marescaux, Jacques

    2017-07-01

    Augmented reality (AR) is the fusion of computer-generated and real-time images. AR can be used in surgery as a navigation tool, by creating a patient-specific virtual model through 3D software manipulation of DICOM imaging (e.g., CT scan). The virtual model can be superimposed to real-time images enabling transparency visualization of internal anatomy and accurate localization of tumors. However, the 3D model is rigid and does not take into account inner structures' deformations. We present a concept of automated AR registration, while the organs undergo deformation during surgical manipulation, based on finite element modeling (FEM) coupled with optical imaging of fluorescent surface fiducials. Two 10 × 1 mm wires (pseudo-tumors) and six 10 × 0.9 mm fluorescent fiducials were placed in ex vivo porcine kidneys (n = 10). Biomechanical FEM-based models were generated from CT scan. Kidneys were deformed and the shape changes were identified by tracking the fiducials, using a near-infrared optical system. The changes were registered automatically with the virtual model, which was deformed accordingly. Accuracy of prediction of pseudo-tumors' location was evaluated with a CT scan in the deformed status (ground truth). In vivo: fluorescent fiducials were inserted under ultrasound guidance in the kidney of one pig, followed by a CT scan. The FEM-based virtual model was superimposed on laparoscopic images by automatic registration of the fiducials. Biomechanical models were successfully generated and accurately superimposed on optical images. The mean measured distance between the estimated tumor by biomechanical propagation and the scanned tumor (ground truth) was 0.84 ± 0.42 mm. All fiducials were successfully placed in in vivo kidney and well visualized in near-infrared mode enabling accurate automatic registration of the virtual model on the laparoscopic images. Our preliminary experiments showed the potential of a biomechanical model with fluorescent

  7. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  8. Solitary Fibrous Tumor of the Pancreas: Imaging Findings

    International Nuclear Information System (INIS)

    Kwon, Heon Ju; Byun, Jae Ho; Kang, Jun; Park, Seong Ho; Lee, Moon Gyu

    2008-01-01

    We report here a case of a pathologically proven solitary fibrous tumor of the pancreas. A 54-year-old man was referred to our hospital for further evaluation of a pancreatic mass that was found incidentally. CT, MR imaging, and endoscopic ultrasonography showed a well-defined, enhancing mass with cystic portions of the pancreas body. MR cholangiopancreatography showed no pancreatic duct dilatation. A solitary fibrous tumor of the pancreas is a very rare lesion

  9. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  10. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  11. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    International Nuclear Information System (INIS)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin

    2012-01-01

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  12. Value of 18F-FDG PET/CT Combined With Tumor Markers in the Evaluation of Ascites.

    Science.gov (United States)

    Han, Na; Sun, Xun; Qin, Chunxia; Hassan Bakari, Khamis; Wu, Zhijian; Zhang, Yongxue; Lan, Xiaoli

    2018-05-01

    The purpose of this study is to investigate the value of 18 F-FDG PET/CT combined with assessment of tumor markers in serum or ascites for the diagnosing and determining the prognosis of benign and malignant ascites. Patients with ascites of unknown cause who underwent evaluation with FDG PET/CT were included in this retrospective study. The maximum standardized uptake value (SUV max ) and levels of the tumor markers carbohydrate antigen-125 (CA-125) and carcinoembryonic antigen (CEA) in serum and ascites were recorded. The diagnostic values of FDG PET/CT, CEA and CA-125 levels in serum or ascites, and the combination of imaging plus tumor marker assessment were evaluated. Factors that were predictive of survival were also analyzed. A total of 177 patients were included. Malignant ascites was eventually diagnosed in 104 patients, and benign ascites was diagnosed in the remaining 73 patients. With the use of FDG PET/CT, 44 patients (42.3%) were found to have primary tumors. The sensitivity, specificity, and accuracy of FDG PET/CT were 92.3%, 83.6%, and 88.7%, respectively. CA-125 levels in serum and ascites showed much better sensitivity than did CEA levels, but they showed significantly lower specificity. If the combination of tumor markers and FDG PET/CT was analyzed, the sensitivity, specificity, and accuracy of tumor markers in serum were 96.6%, 78.1%, and 88.7%, and those of tumor markers in ascites were 97.7%, 80.0%, and 90.4%, respectively. Sex may be an important factor affecting survival time (hazard ratio, 0.471; p = 0.004), but age, CEA level, and FDG PET/CT findings could not predict survival. FDG PET/CT combined with assessment of tumor markers, especially CEA, increased the efficacy of diagnosis of ascites of unknown causes. Male sex conferred a poorer prognosis, whereas age, CEA level, and FDG uptake had no predictive significance in patients with malignant ascites.

  13. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality : a digital phantom study

    NARCIS (Netherlands)

    Bernatowicz, K; Keall, P; Mishra, P; Knopf, A; Lomax, A; Kipritidis, J

    PURPOSE: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on

  14. Non-tumor enhancement at the surgical margin on CT after the removal of brain tumors

    International Nuclear Information System (INIS)

    Adachi, Michito; Hosoya, Takaaki; Yamaguchi, Kohichi; Yamada, Kiyotada

    1992-01-01

    Marginal enhancement is occasionally seen at the surgical margin on CT after the total removal of brain tumors. This enhancement disappears in due time, and therefore we call it non-tumor enhancement. It is often difficult, however, to differentiate non-tumor enhancement from tumor recurrence. In this study, we attempted to determine the characteristics of non-tumor enhancement. The subjects of the study consisted of 15 patients with astrocytoma and one with metastatic tumor in whom sequential CT scans had been performed after total removal of the tumor. Based on the observation of these sequential CT scans, the characteristics of non-tumor enhancement were presumed to be as follows: (1) In four cases, enhancement at the surgical margin persisted more than four months after surgery and then disappeared. Therefore, these cases were considered non-tumor enhancement. Prolonged duration of enhancement such as that in these cases is not necessarily due to recurrence. Marginal enhancement within 3 mm in thickness and with a well-demarcated border like that of a flax is likely to be non-tumor enhancement. (author)

  15. Imaging modalities of abdominal tumors in children

    International Nuclear Information System (INIS)

    Reither, M.

    1993-01-01

    Further technological progress in cross-sectional imaging modalities, accumuting experience with increasingly refined hardware and software and accumulating specific contrast media allow new algorithms for the assessment of abdominal tumors in children. However, ultrasound remains the diagnostic method of choice: Conventional roentgenology with or without contrast media is decreasing, but often reveals further differential diagnostic details. MRI is becoming more prominent and is often performed immediately after ultrasound. The inauguration of gradient echo sequences and consequent shorter examination times combined with the elimination of pulsation and motion artefacts extends the diagnostic spectrum of the upper and middle abdomen. The application of oral or rectal contrast agents for imaging of the GI tract ameliorates the differentiation of pathologic processes. Recently volumetric CT/ultrafast CT has been gaining in importance for abdominal examinations in the pediatric age group. CT especially is helpful if there are bony structures in the region being examined. CT, however, involves ionizing radiation and timely administration of oral and intravenous contrast material. Moreover, as pediatric radiologists, we must strongly withstand tendencies to perform CT more often because it is less expensive, rather than avoiding ionizing radiation by using MRI. (orig.) [de

  16. Early Dynamic 68Ga-DOTA-D-Phe1-Tyr3-Octreotide PET/CT in Patients With Hepatic Metastases of Neuroendocrine Tumors.

    Science.gov (United States)

    Sänger, Philipp Wilhelm; Freesmeyer, Martin

    2016-06-01

    Whole-body PET with Ga-DOTA-D-Phe-Tyr-octreotide (Ga-DOTATOC) and contrast-enhanced CT (ceCT) are considered a standard for the staging of neuroendocrine tumors (NETs). This study sought to verify whether early dynamic (ed) Ga-DOTATOC PET/CT can reliably detect liver metastases of NETs (hypervascular, nonhypervascular; positive or negative for somatostatin receptors) and to verify if the receptor positivity has a significant impact on the detection of tumor hypervascularization. Twenty-seven patients with NET were studied by ceCT and standard whole-body PET according to established Ga-DOTATOC protocols. In addition, edPET data were obtained by continuous scanning during the first 300 seconds after bolus injections of the radiotracer. Early dynamic PET required an additional low-dose, native CT image of the liver for the purpose of attenuation correction. Time-activity and time-contrast curves were obtained, the latter being calculated by the difference between tumor and reference regions. Early dynamic PET/CT proved comparable with ceCT in readily identifying hypervascular lesions, irrespective of the receptor status, with activities rising within 16 to 40 seconds. Early dynamic PET/CT also readily identified nonhypervascular, receptor-positive lesions. Positive image contrasts were obtained for hypervascular, receptor-positive lesions, whereas early negative contrasts were obtained for nonhypervascular, receptor-negative lesions. The high image contrast of hypervascular NET metastases in early arterial phases suggests that edPET/CT can become a useful alternative in patients with contraindications to ceCT. The high density of somatostatin receptors did not seem to interfere with the detection of the lesion's hypervascularization.

  17. Non-odontogenic tumors of the facial bones in children and adolescents: role of multiparametric imaging

    International Nuclear Information System (INIS)

    Becker, Minerva; Stefanelli, Salvatore; Poletti, Pierre Alexandre; Merlini, Laura; Rougemont, Anne-Laure

    2017-01-01

    Tumors of the pediatric facial skeleton represent a major challenge in clinical practice because they can lead to functional impairment, facial deformation, and long-term disfigurement. Their treatment often requires a multidisciplinary approach, and radiologists play a pivotal role in the diagnosis and management of these lesions. Although rare, pediatric tumors arising in the facial bones comprise a wide spectrum of benign and malignant lesions of osteogenic, fibrogenic, hematopoietic, neurogenic, or epithelial origin. The more common lesions include Langerhans cell histiocytosis and osteoma, while rare lesions include inflammatory myofibroblastic and desmoid tumors; juvenile ossifying fibroma; primary intraosseous lymphoma; Ewing sarcoma; and metastases to the facial bones from neuroblastoma, Ewing sarcoma, or retinoblastoma. This article provides a comprehensive approach for the evaluation of children with non-odontogenic tumors of the facial skeleton. Typical findings are discussed with emphasis on the added value of multimodality multiparametric imaging with computed tomography (CT), magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI), positron emission tomography CT (PET CT), and PET MRI. Key imaging findings and characteristic histologic features of benign and malignant lesions are reviewed and the respective role of each modality for pretherapeutic assessment and post-treatment follow-up. Pitfalls of image interpretation are addressed and how to avoid them. (orig.)

  18. Non-odontogenic tumors of the facial bones in children and adolescents: role of multiparametric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Minerva; Stefanelli, Salvatore; Poletti, Pierre Alexandre; Merlini, Laura [University of Geneva, Division of Radiology, Department of Imaging and Medical Informatics, Geneva University Hospital, Geneva (Switzerland); Rougemont, Anne-Laure [University of Geneva, Division of Clinical Pathology, Department of Genetic and Laboratory Medicine, Geneva University Hospital, Geneva (Switzerland)

    2017-04-15

    Tumors of the pediatric facial skeleton represent a major challenge in clinical practice because they can lead to functional impairment, facial deformation, and long-term disfigurement. Their treatment often requires a multidisciplinary approach, and radiologists play a pivotal role in the diagnosis and management of these lesions. Although rare, pediatric tumors arising in the facial bones comprise a wide spectrum of benign and malignant lesions of osteogenic, fibrogenic, hematopoietic, neurogenic, or epithelial origin. The more common lesions include Langerhans cell histiocytosis and osteoma, while rare lesions include inflammatory myofibroblastic and desmoid tumors; juvenile ossifying fibroma; primary intraosseous lymphoma; Ewing sarcoma; and metastases to the facial bones from neuroblastoma, Ewing sarcoma, or retinoblastoma. This article provides a comprehensive approach for the evaluation of children with non-odontogenic tumors of the facial skeleton. Typical findings are discussed with emphasis on the added value of multimodality multiparametric imaging with computed tomography (CT), magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI), positron emission tomography CT (PET CT), and PET MRI. Key imaging findings and characteristic histologic features of benign and malignant lesions are reviewed and the respective role of each modality for pretherapeutic assessment and post-treatment follow-up. Pitfalls of image interpretation are addressed and how to avoid them. (orig.)

  19. Local curvature analysis for classifying breast tumors: Preliminary analysis in dedicated breast CT

    International Nuclear Information System (INIS)

    Lee, Juhun; Nishikawa, Robert M.; Reiser, Ingrid; Boone, John M.; Lindfors, Karen K.

    2015-01-01

    Purpose: The purpose of this study is to measure the effectiveness of local curvature measures as novel image features for classifying breast tumors. Methods: A total of 119 breast lesions from 104 noncontrast dedicated breast computed tomography images of women were used in this study. Volumetric segmentation was done using a seed-based segmentation algorithm and then a triangulated surface was extracted from the resulting segmentation. Total, mean, and Gaussian curvatures were then computed. Normalized curvatures were used as classification features. In addition, traditional image features were also extracted and a forward feature selection scheme was used to select the optimal feature set. Logistic regression was used as a classifier and leave-one-out cross-validation was utilized to evaluate the classification performances of the features. The area under the receiver operating characteristic curve (AUC, area under curve) was used as a figure of merit. Results: Among curvature measures, the normalized total curvature (C_T) showed the best classification performance (AUC of 0.74), while the others showed no classification power individually. Five traditional image features (two shape, two margin, and one texture descriptors) were selected via the feature selection scheme and its resulting classifier achieved an AUC of 0.83. Among those five features, the radial gradient index (RGI), which is a margin descriptor, showed the best classification performance (AUC of 0.73). A classifier combining RGI and C_T yielded an AUC of 0.81, which showed similar performance (i.e., no statistically significant difference) to the classifier with the above five traditional image features. Additional comparisons in AUC values between classifiers using different combinations of traditional image features and C_T were conducted. The results showed that C_T was able to replace the other four image features for the classification task. Conclusions: The normalized curvature measure

  20. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  1. MR imaging-guided percutaneous cryotherapy for lung tumors: initial experience.

    Science.gov (United States)

    Liu, Shangang; Ren, Ruimei; Liu, Ming; Lv, Yubo; Li, Bin; Li, Chengli

    2014-09-01

    To evaluate prospectively the initial clinical experience of magnetic resonance (MR) imaging-guided percutaneous cryotherapy of lung tumors. MR imaging-guided percutaneous cryotherapy was performed in 21 patients with biopsy-proven lung tumors (12 men, 9 women; age range, 39-79 y). Follow-up consisted of contrast-enhanced chest computed tomography (CT) scan performed at 3-month intervals to assess tumor control; CT scanning was carried out for 12 months or until death. Cryotherapy procedures were successfully completed in all 21 patients. Pneumothorax occurred in 7 (33.3%) of 21 patients. Chest tube placement was required in one (4.8%) case. Hemoptysis was exhibited by 11 (52.4%) patients, and pleural effusion occurred in 6 (28.6%) patients. Other complications were observed in 14 (66.7%) patients. The mean follow-up period was 10.5 months (range, 9-12 mo) in patients who died. At month 12 of follow-up, 7 (33.3%) patients had a complete response to therapy, and 10 (47.6%) patients showed a partial response. In addition, two patients had stable disease, and two patients developed progressive disease; one patient developed a tumor in the liver, and the other developed a tumor in the brain. The 1-year local control rate was 81%, and 1-year survival rate was 90.5%. MR imaging-guided percutaneous cryotherapy appears feasible, effective, and minimally invasive for lung tumors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  2. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    International Nuclear Information System (INIS)

    Bernatowicz, K.; Knopf, A.; Lomax, A.; Keall, P.; Kipritidis, J.; Mishra, P.

    2015-01-01

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm 3 spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged

  3. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bernatowicz, K., E-mail: kingab@student.ethz.ch; Knopf, A.; Lomax, A. [Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI 5232, Switzerland and Department of Physics, ETH Zürich, Zürich 8092 (Switzerland); Keall, P.; Kipritidis, J., E-mail: john.kipritidis@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, NSW 2006 (Australia); Mishra, P. [Brigham and Womens Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-01-15

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results

  4. Role of PET/CT for precision medicine in lung cancer: perspective of the Society of Nuclear Medicine and Molecular Imaging.

    Science.gov (United States)

    Greenspan, Bennett S

    2017-12-01

    This article discusses the role of PET/CT in contributing to precision medicine in lung cancer, and provides the perspective of the Society of Nuclear Medicine and Molecular Imaging (SNMMI) on this process. The mission and vision of SNMMI are listed, along with the guidance provided by SNMMI to promote best practice in precision medicine. Basic principles of PET/CT are presented. An overview of the use of PET/CT imaging in lung cancer is discussed. In lung cancer patients, PET/CT is vitally important for optimal patient management. PET/CT is essential in determining staging and re-staging of disease, detecting recurrent or residual disease, evaluating response to therapy, and providing prognostic information. PET/CT is also critically important in radiation therapy planning by determining the extent of active disease, including an assessment of functional tumor volume. The current approach in tumor imaging is a significant advance over conventional imaging. However, recent advances suggest that therapeutic response criteria in the near future will be based on metabolic characteristics and will include the evaluation of biologic characteristics of tumors to further enhance the effectiveness of precision medicine in lung cancer, producing improved patient outcomes with less morbidity.

  5. Registration of 3D FMT and CT Images of Mouse via Affine Transformation using Sequential Monte Carlo

    International Nuclear Information System (INIS)

    Xia Zheng; Zhou Xiaobo; Wong, Stephen T. C.; Sun Youxian

    2007-01-01

    It is difficult to directly co-register the 3D FMT (Fluorescence Molecular Tomography) image of a small tumor in a mouse whose maximal diameter is only a few mm with a larger CT image of the entire animal that spans about ten cm. This paper proposes a new method to register 2D flat and 3D CT image first to facilitate the registration between small 3D FMT images and large CT images. A novel algorithm based on SMC (Sequential Monte Carlo) incorporated with least square operation for the registration between the 2D flat and 3D CT images is introduced and validated with simulated images and real images of mice. The visualization of the preliminary alignment of the 3D FMT and CT image through 2D registration shows promising results

  6. Contouring and dose calculation in head and neck cancer radiotherapy after reduction of metal artifacts in CT images

    DEFF Research Database (Denmark)

    Hansen, Christian Rønn; Lübeck Christiansen, Rasmus; Lorenzen, Ebbe Laugaard

    2017-01-01

    of metal artifact reduction (MAR) in H&N patients in terms of delineation consistency and dose calculation precision in radiation treatment planning. Material and methods: Tumor and OAR delineations were evaluated in planning CT scans of eleven oropharynx patients with streaking artifacts in the tumor...... region preceding curative radiotherapy (RT). The GTV-tumor (GTV-T), GTV-node and parotid glands were contoured by four independent observers on standard CT images and MAR images. Dose calculation was evaluated on thirty H&N patients with dental implants near the treated volume. For each patient, the dose...

  7. Using 18F FDG PET/CT to Detect an occult Mesenchymal Tumor Causing Oncogenic Osteomalacia

    International Nuclear Information System (INIS)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Yong Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Lee, Jong Doo; Kang, Won Jun

    2011-01-01

    Oncogenic osteomalacia is a rare paraneoplastic syndrome characterized by renal phosphate excretion, hypophosphatemia, and osteomalacia. This syndrome is often caused by tumors of mesenchymal origin. Patients with oncogenic osteomalacia have abnormal bone mineralization, resulting in a high frequency of fractures. Tumor resection is the treatment of choice, as it will often correct the metabolic imbalance. Although oncogenic osteomalacia is a potentially curable disease, diagnosis is difficult and often delayed because of the small size and sporadic location of the tumor. Bone scintigraphy and radiography best characterize osteoma lacia; magnetic resonance imaging findings are nonspecific. Here, we report a case of oncogenic osteomalacia secondary to a phosphaturic mesenchymal tumor that was successfully detected by 18F fluorodeoxyglucose positron emission tomography/computed tomography ( 18F FDG PET/CT). This case illustrates the advantages of 18F FDG PET/CT in detecting the occult mesenchymal tumor that causes oncogenic osteomalacia.

  8. Management of Renal Tumors by Image-Guided Radiofrequency Ablation: Experience in 105 Tumors

    International Nuclear Information System (INIS)

    Breen, David J.; Rutherford, Elizabeth E.; Stedman, Brian; Roy-Choudhury, Shuvro H.; Cast, James E. I.; Hayes, Matthew C.; Smart, Christopher J.

    2007-01-01

    Aims. In this article we present our experience with radiofrequency ablation (RFA) in the treatment of 105 renal tumors. Materials and Methods. RFA was performed on 105 renal tumors in 97 patients, with a mean tumor size of 32 mm (11-68 mm). The mean patient age was 71.7 years (range, 36-89 years). The ablations were carried out under ultrasound (n = 43) or CT (n = 62) guidance. Imaging follow-up was by contrast-enhanced CT within 10 days and then at 6-monthly intervals. Multivariate analysis was performed to determine variables associated with procedural outcome. Results. Eighty-three tumors were completely treated at a single sitting (79%). Twelve of the remaining tumors were successfully re-treated and a clinical decision was made not to re-treat seven patients. A patient with a small residual crescent of tumor is under follow-up and may require further treatment. In another patient, re-treatment was abandoned due to complicating pneumothorax and difficult access. One patient is awaiting further re-treatment. The overall technical success rate was 90.5%. Multivariate analysis revealed tumor size to be the only significant variable affecting procedural outcome. (p = 0.007, Pearson χ 2 ) Five patients had complications. There have been no local recurrences. Conclusion. Our experience to date suggests that RFA is a safe and effective, minimally invasive treatment for small renal tumors

  9. In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models

    Directory of Open Access Journals (Sweden)

    Dawn Cavanaugh

    2004-01-01

    Full Text Available Micro-computed tomography (micro-CT is becoming an accepted research tool for the noninvasive examination of laboratory animals such as mice and rats, but to date, in vivo scanning has largely been limited to the evaluation of skeletal tissues. We use a commercially available micro-CT device to perform respiratory gated in vivo acquisitions suitable for thoracic imaging. The instrument is described, along with the scan protocol and animal preparation techniques. Preliminary results confirm that lung tumors as small as 1 mm in diameter are visible in vivo with these methods. Radiation dose was evaluated using several approaches, and was found to be approximately 0.15 Gy for this respiratory-gated micro-CT imaging protocol. The combination of high-resolution CT imaging and respiratory-gated acquisitions appears well-suited to serial in vivo scanning.

  10. FDG-PET/CT imaging for staging and target volume delineation in conformal radiotherapy of anal carcinoma

    International Nuclear Information System (INIS)

    Krengli, Marco; Inglese, Eugenio; Milia, Maria E; Turri, Lucia; Mones, Eleonora; Bassi, Maria C; Cannillo, Barbara; Deantonio, Letizia; Sacchetti, Gianmauro; Brambilla, Marco

    2010-01-01

    FDG-PET/CT imaging has an emerging role in staging and treatment planning of various tumor locations and a number of literature studies show that also the carcinoma of the anal canal may benefit from this diagnostic approach. We analyzed the potential impact of FDG-PET/CT in stage definition and target volume delineation of patients affected by carcinoma of the anal canal and candidates for curative radiotherapy. Twenty seven patients with biopsy proven anal carcinoma were enrolled. Pathology was squamous cell carcinoma in 20 cases, cloacogenic carcinoma in 3, adenocarcinoma in 2, and basal cell carcinoma in 2. Simulation was performed by PET/CT imaging with patient in treatment position. Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) were drawn on CT and on PET/CT fused images. PET-GTV and PET-CTV were respectively compared to CT-GTV and CT-CTV by Wilcoxon rank test for paired data. PET/CT fused images led to change the stage in 5/27 cases (18.5%): 3 cases from N0 to N2 and 2 from M0 to M1 leading to change the treatment intent from curative to palliative in a case. Based on PET/CT imaging, GTV and CTV contours changed in 15/27 (55.6%) and in 10/27 cases (37.0%) respectively. PET-GTV and PET-CTV resulted significantly smaller than CT-GTV (p = 1.2 × 10 -4 ) and CT-CTV (p = 2.9 × 10 -4 ). PET/CT-GTV and PET/CT-CTV, that were used for clinical purposes, were significantly greater than CT-GTV (p = 6 × 10 -5 ) and CT-CTV (p = 6 × 10 -5 ). FDG-PET/CT has a potential relevant impact in staging and target volume delineation of the carcinoma of the anal canal. Clinical stage variation occurred in 18.5% of cases with change of treatment intent in 3.7%. The GTV and the CTV changed in shape and in size based on PET/CT imaging

  11. Three-dimensional segmentation of the tumor mass in computed tomographic images of neuroblastoma

    Science.gov (United States)

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Boag, Graham S.

    2004-05-01

    Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, fibrosis, and normal tissue are often intermixed. Rather than attempt to separate these tissue types into distinct regions, we propose to explore methods to delineate the normal structures expected in abdominal CT images, remove them from further consideration, and examine the remaining parts of the images for the tumor mass. We explore the use of fuzzy connectivity for this purpose. Expert knowledge provided by the radiologist in the form of the expected structures and their shapes, HU values, and radiological characteristics are also incorporated in the segmentation algorithm. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative assessment of the response to chemotherapy and in the planning of delayed surgery for resection of the tumor. The performance of the algorithm is evaluated using cases acquired from the Alberta Children's Hospital.

  12. Feasibility study of image guided radiotherapy for lung tumor using online and offline cone-beam CT setup verification

    International Nuclear Information System (INIS)

    Li Hongsheng; Li Baosheng; Lu Jie; Yin Yong; Yu Ningsha; Chen Yiru

    2009-01-01

    Objective: To investigate the feasibility of online and offline cone-beam CT(CBCT) guided radiotherapy for lung cancer. Methods: Fourteen patients with lung tumor treated by three-dimensional conformal radiotherapy were investigated. Online kV CBCT scan, image registration and setup correction were performed before and immediately after radiotherapy. CBCT online-guided correction data were used to calculate the population-based CTV-PTV margins under the condition of non-correction and correction in every fraction respectively. The numbers of initial images and the population-based CTV-PTV margins after the offline compensation of the system setup error were evaluated with the permission of 0.5 mm and 1.5 mm maximal residue error, respectively. Results: Under the condition of non-correction, the required margins for total error were 5.7 mm, 8.0 mm and 7.8 mm in the left-right (x axis), cranio-caudal (y axis) and anterior-posterior(z axis) directions, respectively. When the tumor was corrected in every fraction, the required margins for intra-fraction error were 2.4 mm, 2.4 mm and 2.3 mm in x,y and z axes, respectively. To correct the systematic setup error, 9 sets of CBCT images for 3.3 mm, 3.7 mm and 3.6 mm PTV margins, and 7 sets of CBCT images for 3.9 mm, 4.3 mm and 4.3 mm PTV margins in x,y and z axes were necessary when 0.5 mm and 1.5 mm maximal residue error were permitted respectively. Conclusions: Both of the online CBCT correction and the offline adaptive correction can markedly reduce the impact of setup error and reduce the required PTV margins accordingly. It is feasible to deliver the online and offline image guided radiation for patients with lung tumor. (authors)

  13. CT findings of malignant nasal cavity tumors

    International Nuclear Information System (INIS)

    Ku, Young Mi; Chun, Kyung Ah; Choi, Kyu Ho; Yu, Won Jong; Kim, Young Joo; Kim, Sung Hoon; Park, Seog Hee; Shinn, Kyung Sub

    1997-01-01

    To evaluate the CT findings of malignant nasal cavity tumors. Retrospective analysis was performed on 20 patients with pathologically-proven malignant nasal cavity tumors. Using CT, we analysed their location, extent of bone destruction and of involvement of adjacent structures, and enhancing pattern. A total of 20 cases included nine squamous cell carcinomas, three olfactory neuroblastomas, three lymphomas, two polymorphic reticulosis, one adenoid cystic carcinoma, one undifferentiated carcinoma and one metastasis from renal cell carcinoma. All cases except one adenoid cystic carcinoma and one squamous cell carcinoma revealed bone destruction or erosion. Aggressive bone destruction and irregular enhancement were seen in eight cases of squamous cell carcinoma, seven cases of which showed involvement of the adjacent paranasal sinuses, nasopharynx, and orbit. Olfactory neuroblastomas were centered in the superior nasal cavity and the adjacent ethmoid sinus, and erosion or destruction of the cribriform plate had occurred. Lymphomas showed bilateral involvement, with uniform contrast enhancement. Polymorphic reticuloses showed perforation or erosion of the nasal septum, with bilateral involvement of the nasal cavity. The location, presence of bone destruction, involvement of adjacent structures, and enhancement pattern of tumor on CT can be helpful for the differential diagnosis of malignant nasal cavity tumors

  14. PET/SPECT/CT multimodal imaging in a transgenic mouse model of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boisgard, R.; Alberini, J.L.; Jego, B.; Siquier, K.; Theze, B.; Guillermet, S.; Tavitian, B. [Service Hospitalier Frederic Joliot, Institut d' Imagerie BioMedicale, CEA, 91 - Orsay (France); Inserm, U803, 91 - Orsay (France)

    2008-02-15

    Background. - In the therapy monitoring of breast cancer, conventional imaging methods include ultrasound, mammography, CT and MRI, which are essentially based on tumor size modifications. However these modifications represent a late consequence of the biological response and fail to differentiate scar or necrotic tissue from residual viable tumoral tissue. Therefore, a current objective is to develop tools able to predict early response to treatment. Positron Emission Tomography (PET) and Single Photon Emission Computerized Tomography (SPECT) are imaging modalities able to provide extremely sensitive quantitative molecular data and are widely used in humans and animals. Results. - Mammary epithelial cells of female transgenic mice expressing the polyoma middle T onco-protein (Py M.T.), undergo four distinct stages of tumour progression, from pre malignant to malignant stages. Stages are identifiable in the mammary tissue and can lead to the development of distant metastases Longitudinal studies by dynamic whole body acquisitions by multimodal imaging including PET, SPECT and Computed Tomography (CT) allow following the tumoral evolution in Py M.T. mice in comparison with the histopathological analysis. At four weeks of age, mammary hyperplasia was identified by histopathology, but no abnormalities were found by palpation or detected by PET with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose. Such as in some human mammary cancers, the sodium iodide sym-porter (N.I.S.) in tumoral mammary epithelial cells is expressed in this mouse model. In order to investigate the expression of N.I.S. in the Py M.T. mice mammary tumours, [{sup 99m}Tc]TcO{sub 4} imaging was performed with a dedicated SPECT/CT system camera (B.I.O.S.P.A.C.E. Gamma Imager/CT). Local uptake of [{sup 99m}Tc]TcO{sub 4} was detected as early as four weeks of age. The efficacy of chemotherapy was evaluated in this mouse model using a conventional regimen (Doxorubicine, 100 mg/ kg) administered weekly from nine to

  15. An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    Science.gov (United States)

    Rozario, Timothy; Bereg, Sergey; Yan, Yulong; Chiu, Tsuicheng; Liu, Honghuan; Kearney, Vasant; Jiang, Lan; Mao, Weihua

    2015-05-08

    In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, global image intensity discrepancies exist between DRRs and projections due to their different image orientations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported to match imperfectly matched projection images and DRRs. The kV projection images were matched with different DRRs in two steps. Preprocessing was performed in advance to generate two sets of DRRs. The tumors were removed from the planning 3D CT for a single phase of planning 4D CT images using planning contours of tumors. DRRs of background and DRRs of tumors were generated separately for every projection angle. The first step was to match projection images with DRRs of background signals. This method divided global images into a matrix of small tiles and similarities were evaluated by calculating normalized cross-correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) was automatically optimized to keep the tumor within a single projection tile that had a bad matching with the corresponding DRR tile. A pixel-based linear transformation was determined by linear interpolations of tile transformation results obtained during tile matching. The background DRRs were transformed to the projection image level and subtracted from it. The resulting subtracted image now contained only the tumor. The second step was to register DRRs of tumors to the subtracted image to locate the tumor. This method was successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (BrainLAB) for dynamic tumor tracking on phantom studies. Radiation opaque markers were

  16. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  17. MR imaging of solitary fibrous tumors in the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong [The Catholic University, Daejeon (Korea, Republic of); Lee, Ho Kyu; Shin, Ji Hoon; Lee, Jeong Hyun [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Seo, Jeong Jin [Chonnam National University Medical School, Kwangju (Korea, Republic of); Kim, Hyung Jim [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jeong, Ae Kyung [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2005-09-15

    Solitary fibrous tumor (SFT) is a very rare tumor. The purpose of this study is to determine the MR imaging features of SFT in the intracranial and extracranial head and neck regions. We retrospectively reviewed six MR images and two CT images of six histologically proven cases of SFT that occurred in four men and two women, and their ages ranged from 46 to 59 years. These imaging findings were correlated with the microscopic findings of their surgical specimens. Six SFTs arose in the meninges (the petrous ridge and the pituitary fossa), the parotid gland, the parapharyngeal space, the buccal space and the maxillary sinus. On the MR images, SFTs in the intracranial and extracranial head and neck regions were mostly isointense to the muscle on the T1-weighted images, they were hyperintense on the T2-weighted images and they all had intense enhancement. On the T1- and T2-weighted images, hypointense lines were observed within in five SFTs. On the CT images, the SFTs were hypodense to the muscle on the unenhanced images and they were heterogeneously enhanced on the contrast-enhanced images. An exceptional case of pituitary SFT was hypointense on the T2-weighted images and it was hyperdense on the unenhanced CT images, which correlated with the increased collagenous component and the cellular compactness. The imaging features of SFT are nonspecific; however, SFT should be included in the differential diagnosis of masses involving the intracranial and extracranial head and neck regions.

  18. MR imaging of solitary fibrous tumors in the head and neck

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Lee, Ho Kyu; Shin, Ji Hoon; Lee, Jeong Hyun; Seo, Jeong Jin; Kim, Hyung Jim; Jeong, Ae Kyung

    2005-01-01

    Solitary fibrous tumor (SFT) is a very rare tumor. The purpose of this study is to determine the MR imaging features of SFT in the intracranial and extracranial head and neck regions. We retrospectively reviewed six MR images and two CT images of six histologically proven cases of SFT that occurred in four men and two women, and their ages ranged from 46 to 59 years. These imaging findings were correlated with the microscopic findings of their surgical specimens. Six SFTs arose in the meninges (the petrous ridge and the pituitary fossa), the parotid gland, the parapharyngeal space, the buccal space and the maxillary sinus. On the MR images, SFTs in the intracranial and extracranial head and neck regions were mostly isointense to the muscle on the T1-weighted images, they were hyperintense on the T2-weighted images and they all had intense enhancement. On the T1- and T2-weighted images, hypointense lines were observed within in five SFTs. On the CT images, the SFTs were hypodense to the muscle on the unenhanced images and they were heterogeneously enhanced on the contrast-enhanced images. An exceptional case of pituitary SFT was hypointense on the T2-weighted images and it was hyperdense on the unenhanced CT images, which correlated with the increased collagenous component and the cellular compactness. The imaging features of SFT are nonspecific; however, SFT should be included in the differential diagnosis of masses involving the intracranial and extracranial head and neck regions

  19. LCP nanoparticle for tumor and lymph node metastasis imaging

    Science.gov (United States)

    Tseng, Yu-Cheng

    A lipid/calcium/phosphate (LCP) nanoparticle formulation (particle diameter ˜25 nm) has previously been developed to delivery siRNA with superior efficiency. In this work, 111In was formulated into LCP nanoparticles to form 111In-LCP for SPECT/CT imaging. With necessary modifications and improvements of the LCP core-washing and surface-coating methods, 111In-LCP grafted with polyethylene glycol exhibited reduced uptake by the mononuclear phagocytic system. SPECT/CT imaging supported performed biodistribution studies, showing clear tumor images with accumulation of 8% or higher injected dose per gram tissue (ID/g) in subcutaneous, human-H460, lung-cancer xenograft and mouse-4T1, breast cancer metastasis models. Both the liver and the spleen accumulated ˜20% ID/g. Accumulation in the tumor was limited by the enhanced permeation and retention effect and was independent of the presence of a targeting ligand. A surprisingly high accumulation in the lymph nodes (˜70% ID/g) was observed. In the 4T1 lymph node metastasis model, the capability of intravenously injected 111In-LCP to visualize the size-enlarged and tumor-loaded sentinel lymph node was demonstrated. By analyzing the SPECT/CT images taken at different time points, the PK profiles of 111In-LCP in the blood and major organs were determined. The results indicated that the decrement of 111In-LCP blood concentration was not due to excretion, but to tissue penetration, leading to lymphatic accumulation. Larger LCP (diameter ˜65 nm) nanoparticles were also prepared for the purpose of comparison. Results indicated that larger LCP achieved slightly lower accumulation in the tumor and lymph nodes, but much higher accumulation in the liver and spleen; thus, larger nanoparticles might not be favorable for imaging purposes. We also demonstrated that LCP with a diameter of ˜25 nm were better able to penetrate into tissues, travel in the lymphatic system and preferentially accumulate in the lymph nodes due to 1) small

  20. Prognostic value of tumor necrosis at CT in diffuse large B-cell lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com [Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht (Netherlands); Klerk, John M.H. de [Department of Nuclear Medicine, Meander Medical Center, Amersfoort (Netherlands); Fijnheer, Rob [Department of Hematology, Meander Medical Center, Amersfoort (Netherlands); Dubois, Stefan V. [Department of Pathology, Meander Medical Center, Amersfoort (Netherlands); Nievelstein, Rutger A.J.; Kwee, Thomas C. [Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht (Netherlands)

    2015-03-15

    Highlights: •CT is compulsory for staging newly diagnosed DLBCL. •Approximately 13.7% of DLBCL patients have tumor necrosis at CT. •Tumor necrosis status at CT is not associated with any NCCN-IPI factor. •Patients with tumor necrosis at CT have a significantly worse outcome. -- Abstract: Objective: To determine the prognostic value of tumor necrosis at computed tomography (CT) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Materials and methods: This retrospective study included 51 patients with newly diagnosed DLBCL who had undergone both unenhanced and intravenous contrast-enhanced CT before R-CHOP (rituximab, cyclophosphamide, hydroxydaunorubicin, oncovin and prednisolone) chemo-immunotherapy. Presence of tumor necrosis was visually and quantitatively assessed at CT. Associations between tumor necrosis status at CT and the National Comprehensive Cancer Network (NCCN) International Prognostic Index (IPI) factors were assessed. Cox regression analysis was used to determine the prognostic impact of NCCN-IPI scores and tumor necrosis status at CT. Results: There were no correlations between tumor necrosis status at CT and the NCCN-IPI factors categorized age (ρ = −0.042, P = 0.765), categorized lactate dehydrogenase (LDH) ratio (ρ = 0.201, P = 0.156), extranodal disease in major organs (φ = −0.245, P = 0.083), Ann Arbor stage III/IV disease (φ = −0.208, P = 0.141), and Eastern Cooperative Oncology Group (ECOG) performance status (φ = 0.015, P = 0.914). In the multivariate Cox proportional hazards model, only tumor necrosis status at CT was an independent predictive factor of progression-free survival (P = 0.003) and overall survival (P = 0.004). Conclusion: The findings of this study indicate the prognostic potential of tumor necrosis at CT in newly diagnosed DLBCL.

  1. Value of PET and PET-CT for monitoring tumor therapy

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2007-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) PET or PET-CT is an accurate test for differentiating residual viable tumor tissue from therapy-induced changes in tumor. Furthermore, quantitative assessment of therapy-induced changes in tumor 18 F-FDG uptake may allow the prediction of tumor response. Treatment may be adjusted according to tumor response. So it is increasingly used to monitor tumor response in patients undergoing chemotherapy and chemoradiotherapy. Here we focused on practical aspects of 18 F-FDG PET or PET-CT for treatment monitoring and on the existing advantages and challenges. (authors)

  2. Value of surveillance {sup 18}F FDG PET/CT in colorectal cancer:comparison with conventional imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Eun Kyoung; Yoo, Ie Ryung; Park, Hye Lim; Choi, Hyun Su; Han, Eun Ji; Kim, Sung Hoon; Chung, Soo Kyo; O, Joo Hyun [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2012-09-15

    To assess the value of PET/CT for detecting local or distant recurrence in patients who undergo surgery for colorectal cancer (CRC)and to compare the accuracy of PET/CT to that of conventional imaging studies (CIS). Tumor surveillance PET/CT scans done between March 2005 and December 2009 of disease free patients after surgery with or without adjuvant chemotherapy for CRC were retrospectively studied. CIS (serial enhanced CT from lung base to pelvis and plain chest radiograph)were performed within 1 month of PET/CT. We excluded patients with distant metastasis on initial staging, a known recurrent tumor, and a lack of follow up imaging. The final diagnosis was based on at least 6 months of follow up with colonoscopy, biopsy, and serial imaging studies in combination with carcinoembryonic antigen levels. A total of 262 PET/CT scans of 245 patients were included. Local and distant recurrences were detected in 27 cases (10.3%). On case based analysis, the overall sensitivity, specificity, and accuracy were 100, 97.0, and 97.3% for PET/CT and 85.1, 97.0, and 95.8% for CIS, respectively. On lesion based analysis, PET/CT detected more lesions compared to CIS in local recurrence and lung metastasis. PET/CT and CIS detected the same number of lesions in abdominal lymph nodes, hepatic metastasis, and peritoneal carcinomatosis. PET/CT detected two more metachronous tumors than did CIS in the lung and thyroid gland. PET/CT detected more recurrences in patients who underwent surgery for CRC than did CIS and had the additional advantage of evaluating the entire body during a single scan.

  3. Computed tomography of liver tumors, 2. Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor by dynamic CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Akira; Fukuoka, Haruhito; Kashiwado, Kouzou; Ichiki, Toshio; Makidono, Yoko [Hiroshima Red Cross Hospital (Japan)

    1984-02-01

    Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor was attempted using dynamic CT scanning. Homogeneous and patchy types were peculiar to hepatocellular carcinoma, and ring-like type to metastatic hepatic tumor. However, with no enhancement, hepatocellular carcinoma could not be denied. Hepatocellular carcinoma was characterized by the enhancement shown on the early stage of dynamic CT. Ring enhancement was not visualized on dynamic CT but visualized on conventional contrast enhanced CT in hepatocellular carcinomas; it was visualized on conventional contrast enhanced CT and on dynamic CT in metastatic hepatic tumors.

  4. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  5. Panoramic three-dimensional CT imaging

    International Nuclear Information System (INIS)

    Kawamata, Akitoshi; Fujishita, Masami

    1998-01-01

    Panoramic radiography is a unique projection technique for producing a single image of both maxillary and mandibular arches and many other anatomical structures. To obtain a similar panoramic image without panoramic radiography system, a modified three-dimensional (3D) CT imaging technique was designed. A set of CT slice image data extending from the chin to the orbit was used for 3D reconstruction. The CT machine used in this study was the X-Vision (TOSHIBA, Japan). The helical scan technique was used. The slice thickness of reconstructed image was one or 1.5 mm. The occlusal plane or Frankfort horizontal (FH) plane was used as the reference line. The resultant slice image data was stored on a magnetic optical disk and then used to create panoramic 3D-CT images on a Macintosh computer systems (Power Macintosh 8600/250, Apple Computer Inc., USA). To create the panoramic 3D-CT image, the following procedure was designed: Design a curved panoramic 3D-CT imaging layer using the imaging layer and the movement of the x-ray beam in panoramic radiography system as a template; Cut this imaging layer from each slice image, then the trimmed image was transformed to a rectangular layer using the ''still image warping'' special effect in the Elastic Reality special effects system (Elastic Reality Inc., USA); Create panoramic 3D-CT image using the Voxel View (Vital Images Inc., USA) rendering system and volume rendering technique. Although the image quality was primitive, a panoramic view of maxillofacial region was obtained by this technique. (author)

  6. Three-dimensional CT virtual endoscopy in the detection of simulated tumors in a novel phantom bladder and ureter model.

    Science.gov (United States)

    Russell, Shane T; Kawashima, Akira; Vrtiska, Terri J; LeRoy, Andrew J; Bruesewitz, Michael R; Hartman, Robert P; Slezak, Jeffrey M; McCollough, Cynthia H; Chow, George K; King, Bernard F

    2005-03-01

    Cystoscopy and ureteroscopy have limitations in the evaluation for urothelial tumors, and both are invasive. We studied the utility of three-dimensional (3D) CT virtual endoscopy in phantom models. A phantom pelvis was constructed of Plexiglas, porcine pelvic bones, and processed animal fat and scanned at various table speeds in a four detector-row CT machine for ability to detect "tumors" of Solidwater plastic polymer. Images were reconstructed at slice thicknesses of 2.5 to 5.0 mm and reconstructed in 3D for evaluation by two radiologists with no knowledge of the scanning parameters or tumor location. Similar studies were performed with a ureter model. With 5-mm slices, the sensitivity for bladder tumors ranged from 67% for 2-mm tumors to 100% for 4-mm tumors, with 12 false-positive findings. The overall sensitivity was 86% with 3.75-mm slices with one false positive, and with 2.5-mm slices, the sensitivity was 93%, again with one false positive. For the ureteral tumors, the overall sensitivities and numbers of false positives were 88.9% and eight with 5.0-mm collimation, 88.9% and four with 3.75-mm collimation, and 100% and three with 2.5-mm collimation. The effective radiation dose for all studies was equivalent to that of a standard abdomen/pelvis scan. Although virtual endoscopy traditionally has had difficulty detecting tumors <5 mm, the multidetector-row CT protocols used in this study could detect most lesions smaller than this. The scan also depicts the other tissues of the pelvis, which is valuable for staging. The 3D images were produced using data from the CT urogram parameters standard at our institution.

  7. Computer-aided diagnosis of liver tumors on computed tomography images.

    Science.gov (United States)

    Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng

    2017-07-01

    Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All

  8. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  9. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  10. Site Specific Discrete PEGylation of 124I-Labeled mCC49 Fab′ Fragments Improves Tumor MicroPET/CT Imaging in Mice

    Science.gov (United States)

    Ding, Haiming; Carlton, Michelle M.; Povoski, Stephen P.; Milum, Keisha; Kumar, Krishan; Kothandaraman, Shankaran; Hinkle, George H.; Colcher, David; Brody, Rich; Davis, Paul D.; Pokora, Alex; Phelps, Mitchell; Martin, Edward W.; Tweedle, Michael F.

    2014-01-01

    The tumor-associated glycoprotein-72 (TAG-72) antigen is highly overexpressed in various human adenocarcinomas and anti-TAG-72 monoclonal antibodies, and fragments are therefore useful as pharmaceutical targeting vectors. In this study, we investigated the effects of site-specific PEGylation with MW 2–4 kDa discrete, branched PEGylation reagents on mCC49 Fab′ (MW 50 kDa) via in vitro TAG72 binding, and in vivo blood clearance kinetics, biodistribution, and mouse tumor microPET/CT imaging. mCC49Fab′ (Fab′-NEM) was conjugated at a hinge region cysteine with maleimide-dPEG12-(dPEG24COOH)3 acid (Mal-dPEG-A), maleimide-dPEG12-(dPEG12COOH)3 acid (Mal-dPEG-B), or maleimide-dPEG12-(m-dPEG24)3 (Mal-dPEG-C), and then radiolabeled with iodine-124 (124I) in vitro radioligand binding assays and in vivo studies used TAG-72 expressing LS174T human colon carcinoma cells and xenograft mouse tumors. Conjugation of mCC49Fab′ with Mal-dPEG-A (Fab′-A) reduced the binding affinity of the non PEGylated Fab′ by 30%; however, in vivo, Fab′-A significantly lengthened the blood retention vs Fab′-NEM (47.5 vs 28.1%/ID at 1 h, 25.1 vs 8.4%/ID at 5 h, p Fab′-NEM by 70%, blood retention, microPET/CT imaging tumor signal intensity, and residual 72 h tumor concentration by 49% (3.83 ± 1.50 vs 1.97 ± 0.29%ID/g, p < 0.05) and 63% (3.83 ± 1.50 vs 1.42 ± 0.35%ID/g, p < 0.05), respectively. We conclude that remarkably subtle changes in the structure of the PEGylation reagent can create significantly altered biologic behavior. Further study is warranted of conjugates of the triple branched, negatively charged Mal-dPEG-A. PMID:24175669

  11. Therapeutic response assessment using 3D ultrasound for hepatic metastasis from colorectal cancer: Application of a personalized, 3D-printed tumor model using CT images.

    Directory of Open Access Journals (Sweden)

    Ye Ra Choi

    Full Text Available To evaluate accuracy and reliability of three-dimensional ultrasound (3D US for response evaluation of hepatic metastasis from colorectal cancer (CRC using a personalized 3D-printed tumor model.Twenty patients with liver metastasis from CRC who underwent baseline and after chemotherapy CT, were retrospectively included. Personalized 3D-printed tumor models using CT were fabricated. Two radiologists measured volume of each 3D printing model using 3D US. With CT as a reference, we compared difference between CT and US tumor volume. The response evaluation was based on Response Evaluation Criteria in Solid Tumors (RECIST criteria.3D US tumor volume showed no significant difference from CT volume (7.18 ± 5.44 mL, 8.31 ± 6.32 mL vs 7.42 ± 5.76 mL in CT, p>0.05. 3D US provided a high correlation coefficient with CT (r = 0.953, r = 0.97 as well as a high inter-observer intraclass correlation (0.978; 0.958-0.988. Regarding response, 3D US was in agreement with CT in 17 and 18 out of 20 patients for observer 1 and 2 with excellent agreement (κ = 0.961.3D US tumor volume using a personalized 3D-printed model is an accurate and reliable method for the response evaluation in comparison with CT tumor volume.

  12. A case of primary neuroendcrine tumor of liver with FDG accumulation by PET/CT

    International Nuclear Information System (INIS)

    Okumura, Yoshihiro; Kishi, Ryotaro; Uka, Mayu; Tsuchihashi, Kazuyo; Hyodo, Takeshi; Takakura, Norihisa; Iguchi, Toshihiro; Kanazawa, Susumu

    2014-01-01

    We report an 80's male with primary hepatic neuroendcrine tumor without clinical symptom. dynamic contrast CT showed a hypervascular tumor at S5 of the liver. EOB-MRI showed high intensity on T2WI, low intensity on T1WI, the hepatic phase and the diffusion weighted image. It showed high FDG accumulation. Pathological examination confirmed neuroendcrine tumor of liver, G2 stage, and owing to the CD56 positive, 12.6% at MIB-1 index, with a little necrosis, no capsule and hemorrhage. (author)

  13. MRI diagnosis of posterior fossa tumors

    International Nuclear Information System (INIS)

    Yamashita, Yasuyuki; Takahashi, Mutsumasa; Sakamoto, Yuuji; Kojima, Ryutarou; Bussaka, Hiromasa; Korogi, Yukunori

    1988-01-01

    Magnetic resonance images (MRI) of 58 patients with posterior fossa tumors were compared with computed tomography (CT). Spin echo (SE) technique and inversion recovery (IR) technique were obtained using 0.22 tesla resistive magnetic resonance unit. MRI was superior to CT in detecting the lesions and showing internal archtecture, hemorrhage, edema of the tumor and displacement of the normal brain. CT was superior to MRI in demonstrating calcification. MRI and CT were comparable in detecting erosions of the skull base, while MRI was superior to CT in showing erosions of the clivus. Most tumors showed hypointensity on T1 weighted images and hyperintensity on T2 weighted images. Meningioma showed equal or almost equal intensity to cerebral gray matter on both SE images. The boundary of intra-axial tumors was unclear in many cases without contrast enhancement using Gd-DTPA, while most extra-axial tumors showed clear margin surrounded by a thin band (rim). In 81.8 % of acoustic neurinomas, signal void rims were demonstrated on both SE images, and they were considered to be vessels around the tumor. The rims of meningioma, on the other hand, were hypointense on T1 weighted images and hyperintense on T2 weighted images. They were considered to be cerebrospinal fluid or capsule around the tumor. It has been concluded that MRI is the most important technique for diagnosis of posterior fossa tumors. (author)

  14. SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y [University of Kansas Hospital, Kansas City, KS (United States); Fullerton, G; Goins, B [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States)

    2015-06-15

    Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement

  15. Using {sup 18F} FDG PET/CT to Detect an occult Mesenchymal Tumor Causing Oncogenic Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Yong Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Oncogenic osteomalacia is a rare paraneoplastic syndrome characterized by renal phosphate excretion, hypophosphatemia, and osteomalacia. This syndrome is often caused by tumors of mesenchymal origin. Patients with oncogenic osteomalacia have abnormal bone mineralization, resulting in a high frequency of fractures. Tumor resection is the treatment of choice, as it will often correct the metabolic imbalance. Although oncogenic osteomalacia is a potentially curable disease, diagnosis is difficult and often delayed because of the small size and sporadic location of the tumor. Bone scintigraphy and radiography best characterize osteoma lacia; magnetic resonance imaging findings are nonspecific. Here, we report a case of oncogenic osteomalacia secondary to a phosphaturic mesenchymal tumor that was successfully detected by {sup 18F} fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18F} FDG PET/CT). This case illustrates the advantages of {sup 18F} FDG PET/CT in detecting the occult mesenchymal tumor that causes oncogenic osteomalacia.

  16. Imaging study of pancreatic ductal adenocarcinomas in Syrian hamsters using X-ray micro-computed tomography (CT)

    International Nuclear Information System (INIS)

    Kitahashi, Tsukasa; Mutoh, Michihiro; Tsurusaki, Masakatsu

    2010-01-01

    X-ray computed tomography (CT) has been used for diagnoses of human pancreatic cancer. Although micro-CT is a useful approach to evaluate macromorphology of organs/tissue also in animal models, reports on pancreatic tumors are limited. In this study, the utility of micro-CT was assessed in characterizing chemically induced pancreatic tumors in Syrian hamsters. Hamsters treated with or without N-nitrosobis(2-oxopropyl)amine (BOP) were injected with the antispasmodic agent, scopolamine butylbromide, and contrast agents, 5 or 10 mL/kg body weight of iopamidol or Fenestra VC at 18-38 weeks, then examined by micro-CT scanning with a respiratory gating system. Both peristaltic and respiratory movements were substantially suppressed by the combination of scopolamine butylbromide treatment and the respiratory gating system, resulting in improvements of image qualities. Iopamidol clearly visualized the pancreatic parenchyma and contrasted the margins among the pancreas and other abdominal organs/tissue. Meanwhile Fenestra VC predominantly contrasted abdominal vascular systems, but the margins among pancreas and other organs/tissue remained obscure. Six pancreatic tumors of 4-13 mm in diameter were detected in four of 15 animals, but not the five tumors of 1-4 mm in diameter. The inner tumor images were heterogeneously or uniformly visualized by iopamidol and Fenestra VC. Overall, iopamidol could clearly contrast between pancreatic parenchyma and the tumors as compared with Fenestra VC. All tumors confirmed were histopathologically diagnosed as pancreatic ductal adenocarcinomas. Thus, micro-CT could be useful to evaluate the carcinogenic processes and preventive methods of pancreatic cancer in hamsters and to assess the novel contrast agents for detection of small pancreatic cancer in humans. (author)

  17. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  18. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  19. A semiautomatic CT-based ensemble segmentation of lung tumors: comparison with oncologists' delineations and with the surgical specimen.

    Science.gov (United States)

    Rios Velazquez, Emmanuel; Aerts, Hugo J W L; Gu, Yuhua; Goldgof, Dmitry B; De Ruysscher, Dirk; Dekker, Andre; Korn, René; Gillies, Robert J; Lambin, Philippe

    2012-11-01

    To assess the clinical relevance of a semiautomatic CT-based ensemble segmentation method, by comparing it to pathology and to CT/PET manual delineations by five independent radiation oncologists in non-small cell lung cancer (NSCLC). For 20 NSCLC patients (stages Ib-IIIb) the primary tumor was delineated manually on CT/PET scans by five independent radiation oncologists and segmented using a CT based semi-automatic tool. Tumor volume and overlap fractions between manual and semiautomatic-segmented volumes were compared. All measurements were correlated with the maximal diameter on macroscopic examination of the surgical specimen. Imaging data are available on www.cancerdata.org. High overlap fractions were observed between the semi-automatically segmented volumes and the intersection (92.5±9.0, mean±SD) and union (94.2±6.8) of the manual delineations. No statistically significant differences in tumor volume were observed between the semiautomatic segmentation (71.4±83.2 cm(3), mean±SD) and manual delineations (81.9±94.1 cm(3); p=0.57). The maximal tumor diameter of the semiautomatic-segmented tumor correlated strongly with the macroscopic diameter of the primary tumor (r=0.96). Semiautomatic segmentation of the primary tumor on CT demonstrated high agreement with CT/PET manual delineations and strongly correlated with the macroscopic diameter considered as the "gold standard". This method may be used routinely in clinical practice and could be employed as a starting point for treatment planning, target definition in multi-center clinical trials or for high throughput data mining research. This method is particularly suitable for peripherally located tumors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Analysis of the sacrum: CT with two-dimensional and three-dimensional imaging

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Scott, W.W. Jr.; Brooker, A.F. Jr.

    1987-01-01

    Fifteen patients with sacral lesions were assessed using CT and volumetric 3D image rendering. Lesions imaged included sacral fractures, tumors, osteomyelitis, dysplasia, and sacroiliac diastasis. In all cases, transaxial CT alone was superior to conventional radiographs, and CT with 3D was more clinically useful than CT alone. The 3D real-time video format allows rotation and manipulation in several planes, including the X (spinal) and Z (somersaulting) axes, for optimal visualization of abnormalities. The Z axis gives unique unimpeded inlet, outlet, and ''bird's-eye'' views of the pelvis and sacrum, enhancing detection and characterization of sacral of SI disruptions and subsequent pelvic ring compromise. Because of the ease of assimilating information in such a format, 3D may become the key modality for preoperative planning and for postoperative follow-up

  1. Differentiation between tuberculosis and primary tumors in the adrenal gland: evaluation with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Yang, Zhi-Gang; Guo, Ying-Kun; Li, Yuan; Min, Peng-Qiu; Yu, Jian-Qun; Ma, En-Sen

    2006-01-01

    The aim of the present study is to determine imaging criteria for differentiating tuberculosis from primary tumors in the adrenal gland on contrast-enhanced CT. Non-contrast and contrast-enhanced CT features in 108 patients with adrenal tuberculosis (n=34) and primary tumor (n=74) were retrospectively assessed for the location, size, calcification and enhancement patterns. The primary tumors included 41 adenomas, 11 pheochromocytomas, 4 carcinomas, 3 lymphomas, 6 myelolipomas, 6 ganglioneuromas, 2 neurilemmomas and 1 ganglioneuroblastoma. Biochemical investigation was performed for all patients. Of the tuberculosis cases, 31 (91%) invaded with bilateral involvement, while 7 (9%) of the primary tumors invaded with bilateral involvement (P<0.001). Tuberculosis often showed calcification (20 of 34; 59%), whereas primary tumors infrequently showed calcification (6 of 74; 8%; P<0.001). Low attenuation in the center with peripheral rim enhancement was more commonly seen in tuberculosis (16 of 34; 47%) than in primary tumors (7 of 74; 9%; P<0.001). In the determination of tuberculosis, the highest sensitivity (91%) and accuracy (91%) were obtained with bilateral involvement, and the highest specificity (99%) was obtained with the contour preserved. In the determination of primary tumors using a combination of having unilateral involvement and being mass-like, the outcome was a sensitivity of 91%, specificity of 94% and accuracy of 92%. CT findings can differentiate tuberculosis from a primary tumor of the adrenal glands with high sensitivity and an acceptable specificity when combined with the endocrinological examination. (orig.)

  2. Assessment of consistency of the whole tumor and single section perfusion imaging with 256-slice spiral CT: a preliminary study

    International Nuclear Information System (INIS)

    Sun Hongliang; Xu Yanyan; Hu Yingying; Tian Yuanjiang; Wang Wu

    2014-01-01

    Objective: To determine the consistency between quantitative CT perfusion measurements of colorectal cancer obtained from single section with maximal tumor dimension and from average of whole tumor, and compare intra- and inter-observer consistency of the two analysis methods. Methods: Twenty-two patients with histologically proven colorectal cancer were examined prospectively with 256-slice CT and the whole tumor perfusion images were obtained. Perfusion parameters were obtained from region of interest (ROI) inserted in single section showing maximal tumor dimension, then from ROI inserted in all tumor-containing sections by two radiologists. Consistency between values of blood flow (BF), blood volume (BV) and time to peak (TTP) calculated by two methods was assessed. Intra-observer consistency was evaluated by comparing repeated measurements done by the same radiologist using both methods after 3 months. Perfusion measurements were done by another radiologist independently to assess inter-observer consistency of both methods. The results from different methods were compared using paired t test and Bland-Altman plot. Results: Twenty-two patients were examined successfully. The perfusion parameters BF, BV and TTP obtained by whole tumor perfusion and single-section analysis were (35.59 ± 14.59) ml · min -1 · 100 g -1 , (17.55 ±4.21) ml · 100 g -1 , (21.30 ±7.57) s and (34.64 ± 13.29)ml · min -1 · 100 g -1 , (17.61 ±6.39)ml · 100 g -1 , (19.82 ±9.01) s, respectively. No significant differences were observed between the means of the perfusion parameters (BF, BV, TTP) calculated by the two methods (t=0.218, -0.033, -0.668, P>0.05, respectively). The intra-observer 95% limits of consistency of perfusion parameters were BF -5.3% to 10.0%, BV -13.8% to 10.8%, TTP -15.0% to 12.6% with whole tumor analysis, respectively; BF -14.3% to 16.5%, BV -24.2% to 22.2%, TTP -19.0% to 16.1% with single section analysis, respectively. The inter-observer 95% limits of

  3. Malignant fatty tumors: classification, clinical course, imaging appearance and treatment

    International Nuclear Information System (INIS)

    Peterson, J.J.; Kransdorf, M.J.; Bancroft, L.W.; O'Connor, M.I.

    2003-01-01

    Liposarcoma is a relatively common soft tissue malignancy with a wide spectrum of clinical presentations and imaging appearances. Several subtypes are described, ranging from lesions nearly entirely composed of mature adipose tissue, to tumors with very sparse adipose elements. The imaging appearance of these fatty masses is frequently sufficiently characteristic to allow a specific diagnosis, while in other cases, although a specific diagnosis is not achievable, a meaningful limited differential diagnosis can be established. The purpose of this paper is to review the spectrum of malignant fatty tumors, highlighting the current classification system, clinical presentation and behavior, treatment and spectrum of imaging appearances. The imaging review will emphasize CT scanning and MR imaging, and will stress differentiating radiologic features. (orig.)

  4. Three-Dimensional Segmentation of the Tumor in Computed Tomographic Images of Neuroblastoma

    OpenAIRE

    Deglint, Hanford J.; Rangayyan, Rangaraj M.; Ayres, Fábio J.; Boag, Graham S.; Zuffo, Marcelo K.

    2006-01-01

    Segmentation of the tumor in neuroblastoma is complicated by the fact that the mass is almost always heterogeneous in nature; furthermore, viable tumor, necrosis, and normal tissue are often intermixed. Tumor definition and diagnosis require the analysis of the spatial distribution and Hounsfield unit (HU) values of voxels in computed tomography (CT) images, coupled with a knowledge of normal anatomy. Segmentation and analysis of the tissue composition of the tumor can assist in quantitative ...

  5. Differentiation of large (≥5 cm) gastrointestinal stromal tumors from benign subepithelial tumors in the stomach: Radiologists’ performance using CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ye Ra [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Sun-Ah [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Hyung Jin; Kim, Seong Ho [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2014-02-15

    Purpose: To identify significant CT findings for the differentiation of large (≥5 cm) gastric gastrointestinal stromal tumors (GIST) from benign subepithelial tumors and to assess whether radiologists’ performance in differentiation is improved with knowledge of significant CT criteria. Materials and methods: One-hundred twenty patients with pathologically proven large (≥5 cm) GISTs (n = 99), schwannomas (n = 16), and leiomyomas (n = 5) who underwent CT were enrolled. Two radiologists (A and B) retrospectively reviewed their CT images in consensus for the location, size, degree and pattern of enhancement, contour, growth pattern and the presence of calcification, necrosis, surface ulceration, or enlarged lymph nodes. CT findings considered significant for differentiation were determined using uni- and multivariate statistical analyses. Thereafter, two successive review sessions for the differentiation of GIST from non-GIST were independently performed by two other reviewers (C and D) with different expertise of 2 and 9 years using a 5-point confidence scale. At the first session, reviewers interpreted CT images without knowledge of significant CT findings. At the second session, the results of statistical analyses were provided to the reviewers. To assess improvement in radiologists’ performance, a pairwise comparison of receiver operating curves (ROC) was performed. Results: Heterogeneous enhancement, presence of necrosis, absence of lymph nodes, and mean size of ≥6 cm were found to be significant for differentiating GIST from schwannoma (P < 0.05). Non-cardial location, heterogeneous enhancement, and presence of necrosis were differential CT features of GIST from leiomyoma (P < 0.05). Multivariate analyses indicated that absence of enlarged LNs was the only statistically significant variable for GIST differentiating from schwannoma. The area under the curve of both reviewers obtained using ROC significantly increased from 0.682 and 0.613 to 0.903 and 0

  6. Visualization of Tumor Angiogenesis Using MR Imaging Contrast Agent Gd-DTPA-anti-VEGF Receptor 2 Antibody Conjugate in a Mouse Tumor Model

    International Nuclear Information System (INIS)

    Jun, Hong Young; Yin, Hong Hua; Kim, Sun Hee; Park, Seong Hoon; Kim, Hun Soo; Yoon Kwon Ha Yoon

    2010-01-01

    To visualize tumor angiogenesis using the MRI contrast agent, Gd- DTPA-anti-VEGF receptor 2 antibody conjugate, with a 4.7-Tesla MRI instrument in a mouse model. We designed a tumor angiogenesis-targeting T1 contrast agent that was prepared by the bioconjugation of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) and an anti-vascular endothelial growth factor receptor-2 (VEGFR2) antibody. The specific binding of the agent complex to cells that express VEGFR2 was examined in cultured murine endothelial cells (MS-1 cells) with a 4.7-Tesla magnetic resonance imaging scanner. Angiogenesis-specific T1 enhancement was imaged with the Gd-DTPA-anti-VEGFR2 antibody conjugate using a CT-26 adenocarcinoma tumor model in eight mice. As a control, the use of the Gd-DTPA-anti-rat immunoglobulin G (Gd-DTPA-anti-rat IgG) was imaged with a tumor model in eight mice. Statistical significance was assessed using the Mann-Whitney test. Tumor tissue was examined by immunohistochemical analysis. The Gd-DTPA-anti-VEGFR2 antibody conjugate showed predominant binding to cultured endothelial cells that expressed a high level of VEGFR2. Signal enhancement was approximately three-fold for in vivo T1-weighted MR imaging with the use of the Gd-DTPA-anti-VEGFR2 antibody conjugate as compared with the Gd-DTPA-rat IgG in the mouse tumor model (p < 0.05). VEGFR2 expression in CT-26 tumor vessels was demonstrated using immunohistochemical staining. MR imaging using the Gd-DTPA-anti-VEGFR2 antibody conjugate as a contrast agent is useful in visualizing noninvasively tumor angiogenesis in a murine tumor model

  7. Visualization of Tumor Angiogenesis Using MR Imaging Contrast Agent Gd-DTPA-anti-VEGF Receptor 2 Antibody Conjugate in a Mouse Tumor Model

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Hong Young; Yin, Hong Hua; Kim, Sun Hee; Park, Seong Hoon; Kim, Hun Soo; Yoon Kwon Ha Yoon [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2010-08-15

    To visualize tumor angiogenesis using the MRI contrast agent, Gd- DTPA-anti-VEGF receptor 2 antibody conjugate, with a 4.7-Tesla MRI instrument in a mouse model. We designed a tumor angiogenesis-targeting T1 contrast agent that was prepared by the bioconjugation of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) and an anti-vascular endothelial growth factor receptor-2 (VEGFR2) antibody. The specific binding of the agent complex to cells that express VEGFR2 was examined in cultured murine endothelial cells (MS-1 cells) with a 4.7-Tesla magnetic resonance imaging scanner. Angiogenesis-specific T1 enhancement was imaged with the Gd-DTPA-anti-VEGFR2 antibody conjugate using a CT-26 adenocarcinoma tumor model in eight mice. As a control, the use of the Gd-DTPA-anti-rat immunoglobulin G (Gd-DTPA-anti-rat IgG) was imaged with a tumor model in eight mice. Statistical significance was assessed using the Mann-Whitney test. Tumor tissue was examined by immunohistochemical analysis. The Gd-DTPA-anti-VEGFR2 antibody conjugate showed predominant binding to cultured endothelial cells that expressed a high level of VEGFR2. Signal enhancement was approximately three-fold for in vivo T1-weighted MR imaging with the use of the Gd-DTPA-anti-VEGFR2 antibody conjugate as compared with the Gd-DTPA-rat IgG in the mouse tumor model (p < 0.05). VEGFR2 expression in CT-26 tumor vessels was demonstrated using immunohistochemical staining. MR imaging using the Gd-DTPA-anti-VEGFR2 antibody conjugate as a contrast agent is useful in visualizing noninvasively tumor angiogenesis in a murine tumor model

  8. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  9. Spectrum of fluorodeoxyglucose-positron emission tomography/computed tomography and magnetic resonance imaging findings of ovarian tumors.

    Science.gov (United States)

    Kitajima, Kazuhiro; Ueno, Yoshiko; Maeda, Tetsuo; Murakami, Koji; Kaji, Yasushi; Kita, Masato; Suzuki, Kayo; Sugimura, Kazuro

    2011-11-01

    The purpose of this article is to review fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI) findings in a variety of benign, malignant, and borderline malignant ovarian tumors. It is advantageous to become familiar with the wide variety of FDG-PET/CT findings of this entity. Benign ovarian tumors generally have faint uptake, whereas endometriomas, fibromas, and teratomas show mild to moderate uptake. Malignant ovarian tumors generally have intense uptake, whereas tumors with a small solid component often show minimal uptake.

  10. Computed tomography (CT) of the parapharyngeal space tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kuriyama, K.; Narumi, Y.; Fujita, M.; Sato, T.; Kajita, A.; Sakai, Y.; Tanaka, H.; Nakanishi, K.; Fujino, Y.

    1987-04-01

    The parapharyngeal space is of great clinical importance. Because of its location deep within the neck, this space is difficult to be examined by ordinary methods but can be well demonstrated by CT. Ten patients with parapharyngeal space tumors were examined with CT. They consisted of 3 pleomorphic adenomas, 1 myoepitherioma, 1 metastatic lymphadenopathy, 1 branchial cleft cyst, 2 schwannomas, 1 neurofibroma and 1 branchiogenic carcinoma respectively. Parapharyngeal space is divided into parapharyngeal space (prestyloid space), carotid space (retrostyloid space), and retropharyngeal space. It is important to determine localization and mapping of parapharyngeal tumors, because the characteristic tumor types in histologic terms are found in each subdivision of parapharyngeal space.

  11. Combined FDG-PET/CT for the detection of unknown primary tumors: systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Kwee, Thomas C.; Kwee, Robert M.

    2009-01-01

    The aim of this study was to systematically review and meta-analyze published data on the diagnostic performance of combined 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in the detection of primary tumors in patients with cancer of unknown primary (CUP). A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Methodological quality of the included studies was assessed. Reported detection rates, sensitivities and specificities were meta-analyzed. Subgroup analyses were performed if results of individual studies were heterogeneous. The 11 included studies, comprising a total sample size of 433 patients with CUP, had moderate methodological quality. Overall primary tumor detection rate, pooled sensitivity and specificity of FDG-PET/CT were 37%, 84% (95% CI 78-88%) and 84% (95% CI 78-89%), respectively. Sensitivity was heterogeneous across studies (P = 0.0001), whereas specificity was homogeneous across studies (P = 0.2114). Completeness of diagnostic workup before FDG-PET/CT, location of metastases of unknown primary, administration of CT contrast agents, type of FDG-PET/CT images evaluated and way of FDG-PET/CT review did not significantly influence diagnostic performance. In conclusion, FDG-PET/CT can be a useful method for unknown primary tumor detection. Future studies are required to prove the assumed advantage of FDG-PET/CT over FDG-PET alone and to further explore causes of heterogeneity. (orig.)

  12. Littoral cell angioma of the spleen: CT and MR imaging appearance

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, G.; Uder, M.; Altmeyer, K.; Gruber, M.; Kramann, B. [Univ. Hospital Saarland University, Homburg/Saar (Germany). Dept. of Diagnostic Radiology; Bonkhoff, H. [Department of Pathology, University Hospital, Saarland University, D-66421 Homburg/Saar (Germany)

    2000-09-01

    We report a case of littoral cell angioma (LCA) of the spleen, a recently described splenic pathology, which imaging characteristics and pathologic morphology have been discussed only by a few authors. The imaging findings in unenhanced and contrast-enhanced MRI and CT as well as histologic specimen are presented. Diagnosis was made after elective splenectomy. Differential diagnosis of splenic tumors as well as the imaging findings in this particular case are discussed. (orig.)

  13. Registration and Summation of Respiratory-Gated or Breath-Hold PET Images Based on Deformation Estimation of Lung from CT Image

    Directory of Open Access Journals (Sweden)

    Hideaki Haneishi

    2016-01-01

    Full Text Available Lung motion due to respiration causes image degradation in medical imaging, especially in nuclear medicine which requires long acquisition times. We have developed a method for image correction between the respiratory-gated (RG PET images in different respiration phases or breath-hold (BH PET images in an inconsistent respiration phase. In the method, the RG or BH-PET images in different respiration phases are deformed under two criteria: similarity of the image intensity distribution and smoothness of the estimated motion vector field (MVF. However, only these criteria may cause unnatural motion estimation of lung. In this paper, assuming the use of a PET-CT scanner, we add another criterion that is the similarity for the motion direction estimated from inhalation and exhalation CT images. The proposed method was first applied to a numerical phantom XCAT with tumors and then applied to BH-PET image data for seven patients. The resultant tumor contrasts and the estimated motion vector fields were compared with those obtained by our previous method. Through those experiments we confirmed that the proposed method can provide an improved and more stable image quality for both RG and BH-PET images.

  14. Deep learning methods for CT image-domain metal artifact reduction

    Science.gov (United States)

    Gjesteby, Lars; Yang, Qingsong; Xi, Yan; Shan, Hongming; Claus, Bernhard; Jin, Yannan; De Man, Bruno; Wang, Ge

    2017-09-01

    Artifacts resulting from metal objects have been a persistent problem in CT images over the last four decades. A common approach to overcome their effects is to replace corrupt projection data with values synthesized from an interpolation scheme or by reprojection of a prior image. State-of-the-art correction methods, such as the interpolation- and normalization-based algorithm NMAR, often do not produce clinically satisfactory results. Residual image artifacts remain in challenging cases and even new artifacts can be introduced by the interpolation scheme. Metal artifacts continue to be a major impediment, particularly in radiation and proton therapy planning as well as orthopedic imaging. A new solution to the long-standing metal artifact reduction (MAR) problem is deep learning, which has been successfully applied to medical image processing and analysis tasks. In this study, we combine a convolutional neural network (CNN) with the state-of-the-art NMAR algorithm to reduce metal streaks in critical image regions. Training data was synthesized from CT simulation scans of a phantom derived from real patient images. The CNN is able to map metal-corrupted images to artifact-free monoenergetic images to achieve additional correction on top of NMAR for improved image quality. Our results indicate that deep learning is a novel tool to address CT reconstruction challenges, and may enable more accurate tumor volume estimation for radiation therapy planning.

  15. Comparison of abdominal MRI with diffusion-weighted imaging to {sup 68}Ga-DOTATATE PET/CT in detection of neuroendocrine tumors of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Schmid-Tannwald, Christine; Schmid-Tannwald, Christoph M.; Neumann, Ralph; Nikolaou, Konstantin; Schramm, Nicolai; Reiser, Maximilian F.; Rist, Carsten [Ludwig Maximilians University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Morelli, John N. [Scott and White Hospital Temple, Department of Radiology, Temple, TX (United States); Haug, Alexander R.; Jansen, Nathalie [Ludwig Maximilians University Hospital Munich, Department of Nuclear Medicine, Munich (Germany)

    2013-06-15

    The aim of the study was to evaluate contrast-enhanced MRI, diffusion-weighted MRI (DW MRI), and {sup 68}Ga-DOTATATE positron emission tomography (PET)/CT in the detection of intermediate to well-differentiated neuroendocrine tumors (NET) of the pancreas. Eighteen patients with pathologically proven pancreatic NET who underwent MRI including DW MRI and PET/CT within 6 weeks of each other were included in this retrospective study. Two radiologists evaluated T2-weighted (T2w), T2w + DW MRI, T2w + contrast-enhanced T1-weighted (CE T1w) MR images, and PET/CT for NET detection. The sensitivity and level of diagnostic confidence were compared among modalities using McNemar's test and a Wilcoxon signed rank test. Apparent diffusion coefficients (ADC) of pancreatic NETs and normal pancreatic tissue were compared with Student's t test. Of the NETs, 8/23 (34.8 %) and 9/23 (39.1 %) were detected on T2w images by observers 1 and 2, respectively. Detection rates improved significantly by combining T2w images with DW MRI (observer 1: 14/23 = 61 %; observer 2: 15/23 = 65.2 %; p < 0.05) or CE T1w images (observer 1: 14/23 = 61 %; observer 2: 15/23 = 65.2 %; p < 0.05). Detection rates of pancreatic NET with PET/CT (both observers: 23/23 = 100 %) were statistically significantly higher than with MRI (p < 0.05). The mean ADC value of NET (1.02 {+-} 0.26 x 10{sup -3} mm{sup 2}/s) was statistically significantly lower than that of normal pancreatic tissue (1.48 {+-} 0.39 x 10{sup -3} mm{sup 2}/s). DW MRI is a valuable adjunct to T2w imaging and comparable to CE T1w imaging in pancreatic NET detection, quantitatively differentiating between NET and normal pancreatic tissue with ADC measurements. {sup 68}Ga-DOTATATE PET/CT is more sensitive than MRI in the detection of pancreatic NET. (orig.)

  16. Diagnosis and evaluation of surveying examination by intracranial tumor in dogs CT; Diagnostico e avaliacao topografica de neoplasias intracranianas pelo exame de TC em caes

    Energy Technology Data Exchange (ETDEWEB)

    Romaldini, Andre Fonseca; Santos, Debora Rodrigues dos; Oliveira, Juliana Messias; Abreu, Felipe Andrei Suarez; Wallace, Verena; Pacheco, Eduardo Nelson da Silva, E-mail: andreromaldini@gmail.com [Hospital Santa Ines de Sao Paulo, Santana, SP (Brazil)

    2012-07-01

    The use of computed tomography (CT) revolutionized image diagnostic in veterinary medicine and currently can be considered one of the most useful tools for the imaging evaluation of intracranial tumor in dogs. Computed tomography of the brain in small animals allows visualization of intracranial tumor, compression of adjacent structures such as cerebral parenchyma, falx or lateral ventricles, and evaluate secondary hemorrhages and edema. The CT imaging provides essential information to indicate the surgical approach for a possible tumor resection or biopsy, including the correct location and boundaries structures involved, and also can be used to monitor the clinical treatment. However, only histopathological examination is able to confirm the final diagnosis. (author)

  17. Computed tomography and magnetic resonance imaging findings of peripheral primitive neuroectodermal tumors of the head and neck

    International Nuclear Information System (INIS)

    Zhang Weidong; Chen Yanfeng; Li Chuanxing; Zhang Liang; Xu Zhibin; Zhang Fujun

    2011-01-01

    Purpose: We aimed to analyze the computed tomography (CT) and magnetic resonance imaging (MRI) findings of peripheral primitive neuroectodermal tumor (pPNET) of the head and neck. Methods: Eight patients with pPNET of the head and neck confirmed by histopathological examination were analyzed retrospectively. Results: The average patient age was 8 years. The tumor location in the 8 patients was as follows: maxillofacial region (right, 2; left, 1), left maxillary sinus (1), right masticator space (1), left carotid space (1), right infratemporal fossa (1), and left parotid gland (1). All 5 patients who underwent CT demonstrated ill-defined soft masses and no calcification. Three patients with tumors in the maxillofacial region showed homogeneous small masses and a mild enhancement. The patient with left maxillary sinus tumor showed a heterogeneous mass with patchy, necrotic foci and mild heterogeneous enhancement. The patient with right masticator space tumor showed a heterogeneous mass, and marked heterogeneous enhancement. The T1-weighted images of the patients with right infratemporal fossa, left carotid space, and left parotid gland tumors were isointense. The T2-weighted images were heterogeneous and mildly hyperintense in 2 patients and hyperintense in 1 patient. Heterogeneous intermediate enhancement was demonstrated in 2 patients and mild ring enhancement in 1 patient. Conclusion: The imaging features of pPNET of the head and neck are non-specific. An ill-defined, aggressive mass and variable enhancement on CT and MR images may suggest the diagnosis of pPNET. Peripheral PNET should be included in the differential diagnosis of children and adolescents' regional tumors.

  18. Computed tomography and magnetic resonance imaging findings of peripheral primitive neuroectodermal tumors of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weidong [State Key Laboratory of Oncology in South China, Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong, 510060 (China); Chen Yanfeng [State Key Laboratory of Oncology in South China, Department of Head and Neck Surgery, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong, 510060 (China); Li Chuanxing; Zhang Liang; Xu Zhibin [State Key Laboratory of Oncology in South China, Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong, 510060 (China); Zhang Fujun, E-mail: drzhangfj@163.com [State Key Laboratory of Oncology in South China, Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong, 510060 (China)

    2011-11-15

    Purpose: We aimed to analyze the computed tomography (CT) and magnetic resonance imaging (MRI) findings of peripheral primitive neuroectodermal tumor (pPNET) of the head and neck. Methods: Eight patients with pPNET of the head and neck confirmed by histopathological examination were analyzed retrospectively. Results: The average patient age was 8 years. The tumor location in the 8 patients was as follows: maxillofacial region (right, 2; left, 1), left maxillary sinus (1), right masticator space (1), left carotid space (1), right infratemporal fossa (1), and left parotid gland (1). All 5 patients who underwent CT demonstrated ill-defined soft masses and no calcification. Three patients with tumors in the maxillofacial region showed homogeneous small masses and a mild enhancement. The patient with left maxillary sinus tumor showed a heterogeneous mass with patchy, necrotic foci and mild heterogeneous enhancement. The patient with right masticator space tumor showed a heterogeneous mass, and marked heterogeneous enhancement. The T1-weighted images of the patients with right infratemporal fossa, left carotid space, and left parotid gland tumors were isointense. The T2-weighted images were heterogeneous and mildly hyperintense in 2 patients and hyperintense in 1 patient. Heterogeneous intermediate enhancement was demonstrated in 2 patients and mild ring enhancement in 1 patient. Conclusion: The imaging features of pPNET of the head and neck are non-specific. An ill-defined, aggressive mass and variable enhancement on CT and MR images may suggest the diagnosis of pPNET. Peripheral PNET should be included in the differential diagnosis of children and adolescents' regional tumors.

  19. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  20. Brain tumors and CT scans in infants and children, (3)

    International Nuclear Information System (INIS)

    Oi, Shizuo

    1983-01-01

    In clinical pictures of brain tumors in infants and children, many features are not identical to those in adults, including characteristics of the tumors in age population, the locations of the tumors, the clinical symptoms and signs, and various factors affecting prognosis. We have, therefore, clinically and extensively analyzed brain tumors in infants and children. This study was also performed in order to analyze the characteristic CT findings of astrocytoma, the tumor most frequently occurring among infants and children. The subjects were 24 cases of astrocytoma and 2 cases of glioblastoma in infants and children under 16 years. The locations and characteristics of the tumors were as follows. Most of the tumors occurred in the 4th ventricle, had a characteristic low density, and could almost entirely be clearly distinguished from medulloblastomas, but not from ependymomas, on CT. The features of the supratentorial tumors were similar to those of the astrocytomas and glioblastomas mostly appearing in adults, as previously reported, in the relatively close correlation with the location and malignancy of the tumor. There was also a case of diffuse astrocytoma, a ''non-enhanced low-density solid tumor,'' which raised clinical problems. Among low-grade astrocytomas in infants and children, only a few show a high density on plain CT, many have, at least macroscopically, a strong contrast enhancement, and peritumoral edema is not observed on CT or, if observed, is observed only slightly. As individual features, homogenous enhancement pattern, a mixed density, a central low density, and a rare absence of enhancement are listed. (author)

  1. CT differentiation of infiltrating renal cell carcinoma and renal urothelial tumor

    International Nuclear Information System (INIS)

    Choi, Hyo Kyeong; Goo, Dong Erk; Bang, Sun Woo; Lee, Moon Gyu; Cho, Kyoung Sik; Auh, Yong Ho

    1994-01-01

    It may be difficult to differentiate renal cell carcinoma involving collecting system from renal urothelial tumor invading into renal parenchyma. The purpose of this study was to assess the differences of CT findings between two conditions. CT findings of 5 cases of renal cell carcinoma involving the renal collecting systems and 10 cases of renal urothelial tumors invading the renal parenchyma were compared, and analyzed about the presence or absence of hydronephrosis, normal or abnormal CT nephrogram, renal contour changes due to mass and tentative diagnosis. The diagnoses were confirmed at surgery. Renal cell carcinoma showed hydronephrosis in only 20% and normal CT nephrogram and outward contour bulging in all cases. In contrast, renal urothelial tumor showed hydronephrosis(70%), abnormal CT nephrogram(60%), and preservation of reinform shape(100%). Renal contour changes and CT nephrogram may be useful in distinguishing both disease entities

  2. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  3. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  4. Cross sectional imaging of cardiac tumors

    International Nuclear Information System (INIS)

    Maksimovic, R.

    2012-01-01

    Full text: Primary cardiac tumors are a rare entity whose incidence, according to surgery and autopsy reports, is 0.3% to 0.7% of all cardiac tumors. Metastasis to the heart from other primary cancers is 30 times more common. Only 25% of primary cardiac tumors are malignant, and, of these, 75% are sarcomas. Malignant primary cardiac sarcomas are usually located in the right atrium and are most commonly angiosarcoma. In the left atrium, the most common malignant tumors are pleomorphic sarcoma and leiomyosarcoma. Symptom presentation for cardiac tumors is quite varied, but it is dependent upon tumor location and size, rather than upon histologic characteristics. Presentation includes congestive heart failure from intracardiac obstruction, systemic embolization, constitutional symptoms, and arrhythmias. Left atrial sarcomas tend to be more solid and less infiltrative than right-sided sarcomas; consequently, they tend to metastasize later. They usually present with symptoms of blood-flow obstruction and substantial, life-threatening congestive heart failure. Right-sided cardiac tumors are usually malignant and appear as bulky, infiltrative masses that grow in an outward pattern. These are usually fast-growing tumors that metastasize early and do not present with congestive heart failure until late in the disease. The diagnosis of cardiac tumors relies heavily on the use of multiple imaging techniques, including cardiac computed tomography (CT), cardiovascular magnetic resonance (CMR), and echocardiography. Important imaging data to collect include information on the size of the intracardiac mass, the mobility of the mass (an important predictor of prognosis and embolic potential), myocardial invasion, and cardiac chamber location. These factors will provide the means to diagnosis and prognosis. Other important data to collect include the mechanism of tumor implantation, the relationship of the tumor with adjacent structures, the surgeon route of access to the heart

  5. A Plasmonic Gold Nanostar Theranostic Probe for In Vivo Tumor Imaging and Photothermal Therapy

    Science.gov (United States)

    Liu, Yang; Ashton, Jeffrey R.; Moding, Everett J.; Yuan, Hsiangkuo; Register, Janna K.; Fales, Andrew M.; Choi, Jaeyeon; Whitley, Melodi J.; Zhao, Xiaoguang; Qi, Yi; Ma, Yan; Vaidyanathan, Ganesan; Zalutsky, Michael R.; Kirsch, David G.; Badea, Cristian T.; Vo-Dinh, Tuan

    2015-01-01

    Nanomedicine has attracted increasing attention in recent years, because it offers great promise to provide personalized diagnostics and therapy with improved treatment efficacy and specificity. In this study, we developed a gold nanostar (GNS) probe for multi-modality theranostics including surface-enhanced Raman scattering (SERS) detection, x-ray computed tomography (CT), two-photon luminescence (TPL) imaging, and photothermal therapy (PTT). We performed radiolabeling, as well as CT and optical imaging, to investigate the GNS probe's biodistribution and intratumoral uptake at both macroscopic and microscopic scales. We also characterized the performance of the GNS nanoprobe for in vitro photothermal heating and in vivo photothermal ablation of primary sarcomas in mice. The results showed that 30-nm GNS have higher tumor uptake, as well as deeper penetration into tumor interstitial space compared to 60-nm GNS. In addition, we found that a higher injection dose of GNS can increase the percentage of tumor uptake. We also demonstrated the GNS probe's superior photothermal conversion efficiency with a highly concentrated heating effect due to a tip-enhanced plasmonic effect. In vivo photothermal therapy with a near-infrared (NIR) laser under the maximum permissible exposure (MPE) led to ablation of aggressive tumors containing GNS, but had no effect in the absence of GNS. This multifunctional GNS probe has the potential to be used for in vivo biosensing, preoperative CT imaging, intraoperative detection with optical methods (SERS and TPL), as well as image-guided photothermal therapy. PMID:26155311

  6. CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization

    International Nuclear Information System (INIS)

    Yenice, Kamil M.; Lovelock, D. Michael; Hunt, Margie A.; Lutz, Wendell R.; Fournier-Bidoz, Nathalie; Hua, C.-H.; Yamada, Josh; Bilsky, Mark; Lee, Henry; Pfaff, Karl; Spirou, Spiridon V.; Amols, Howard I.

    2003-01-01

    Purpose: To design and implement a noninvasive stereotactic immobilization technique with daily CT image-guided positioning to treat patients with paraspinal lesions accurately and to quantify the systematic and random patient setup errors occurring with this method. Methods and Materials: A stereotactic body frame (SBF) was developed for 'rigid' immobilization of paraspinal patients. The inherent accuracy of this system for stereotactic CT-guided treatment was evaluated with phantom studies. Seven patients with thoracic and lumbar spine lesions were immobilized with the SBF and positioned for 33 treatment fractions using daily CT scans. For all 7 patients, the daily setup errors, as assessed from the daily CT scans, were corrected at each treatment fraction. A retrospective analysis was also performed to assess what the impact on patient treatment would have been without the CT-based corrections (i.e., if patient setup had been performed only with the SBF). Results: The average magnitude of systematic and random errors from uncorrected patient setups using the SBF was approximately 2 mm and 1.5 mm (1 SD), respectively. For fixed phantom targets, the system accuracy for the SBF localization and treatment was shown to be within 1 mm (1 SD) in any direction. Dose-volume histograms incorporating these uncertainties for an intensity-modulated radiotherapy plan for lumbar spine lesions were generated, and the effects on the dose-volume histograms were studied. Conclusion: We demonstrated a very accurate and precise method of patient immobilization and treatment delivery based on a noninvasive SBF and daily image guidance for paraspinal lesions. The SBF provides excellent immobilization for paraspinal targets, with setup accuracy better than 2 mm (1 SD). However, for highly conformal paraspinal treatments, uncorrected systematic and random errors of 2 mm in magnitude can result in a significantly greater (>100%) dose to the spinal cord than planned, even though the

  7. Imaging features of primary Sarcomas of the great vessels in CT, MRI and PET/CT: a single-center experience

    International Nuclear Information System (INIS)

    Falck, Christian von; Meyer, Bernhard; Fegbeutel, Christine; Länger, Florian; Bengel, Frank; Wacker, Frank; Rodt, Thomas

    2013-01-01

    To investigate the imaging features of primary sarcomas of the great vessels in CT, MRI and 18 F-FDG PET/CT. Thirteen patients with a primary sarcoma of the great vessels were retrospectively evaluated. All available images studies including F-18 FDG PET(/CT) (n = 4), MDCT (n = 12) and MRI (n = 6) were evaluated and indicative image features of this rare tumor entity were identified. The median interval between the first imaging study and the final diagnosis was 11 weeks (0–12 weeks). The most frequently observed imaging findings suggestive of malignant disease in patients with sarcomas of the pulmonary arteries were a large filling defect with vascular distension, unilaterality and a lack of improvement despite effective anticoagulation. In patients with aortic sarcomas we most frequently observed a pedunculated appearance and an atypical location of the filling defect. The F-18 FDG PET(/CT) examinations demonstrated an unequivocal hypermetabolism of the lesion in all cases (4/4). MRI proved lesion vascularization in 5/6 cases. Intravascular unilateral or atypically located filling defects of the great vessels with vascular distension, a pedunculated shape and lack of improvement despite effective anticoagulation are suspicious for primary sarcoma on MDCT or MRI. MR perfusion techniques can add information on the nature of the lesion but the findings may be subtle and equivocal. F-18 FDG PET/CT may have a potential role in these patients and may be considered as part of the imaging workup

  8. SU-F-J-114: On-Treatment Imagereconstruction Using Transit Images of Treatment Beams Through Patient and Thosethrough Planning CT Images

    International Nuclear Information System (INIS)

    Lee, H; Cho, S; Cheong, K; Jung, J; Jung, S; Kim, J; Yeo, I

    2016-01-01

    Purpose: To reconstruct patient images at the time of radiation delivery using measured transit images of treatment beams through patient and calculated transit images through planning CT images. Methods: We hypothesize that the ratio of the measured transit images to the calculated images may provide changed amounts of the patient image between times of planning CT and treatment. To test, we have devised lung phantoms with a tumor object (3-cm diameter) placed at iso-center (simulating planning CT) and off-center by 1 cm (simulating treatment). CT images of the two phantoms were acquired; the image of the off-centered phantom, unavailable clinically, represents the reference on-treatment image in the image quality of planning CT. Cine-transit images through the two phantoms were also acquired in EPID from a non-modulated 6 MV beam when the gantry was rotated 360 degrees; the image through the centered phantom simulates calculated image. While the current study is a feasibility study, in reality our computational EPID model can be applicable in providing accurate transit image from MC simulation. Changed MV HU values were reconstructed from the ratio between two EPID projection data, converted to KV HU values, and added to the planning CT, thereby reconstructing the on-treatment image of the patient limited to the irradiated region of the phantom. Results: The reconstructed image was compared with the reference image. Except for local HU differences>200 as a maximum, excellent agreement was found. The average difference across the entire image was 16.2 HU. Conclusion: We have demonstrated the feasibility of a method of reconstructing on-treatment images of a patient using EPID image and planning CT images. Further studies will include resolving the local HU differences and investigation on the dosimetry impact of the reconstructed image.

  9. SU-F-J-114: On-Treatment Imagereconstruction Using Transit Images of Treatment Beams Through Patient and Thosethrough Planning CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Cho, S [KAIST, Yuseong-gu, Daejeon (Korea, Republic of); Cheong, K [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Jung, J [East Carolina University Greenville, NC (United States); Jung, S [Samsung Medical Cener, Gangnam-gu, Seoul (Korea, Republic of); Kim, J [Yonsei Cancer Center, Seoul (Korea, Republic of); Yeo, I [Loma Linda University Medical Center, Loma Linda, CA (United States)

    2016-06-15

    Purpose: To reconstruct patient images at the time of radiation delivery using measured transit images of treatment beams through patient and calculated transit images through planning CT images. Methods: We hypothesize that the ratio of the measured transit images to the calculated images may provide changed amounts of the patient image between times of planning CT and treatment. To test, we have devised lung phantoms with a tumor object (3-cm diameter) placed at iso-center (simulating planning CT) and off-center by 1 cm (simulating treatment). CT images of the two phantoms were acquired; the image of the off-centered phantom, unavailable clinically, represents the reference on-treatment image in the image quality of planning CT. Cine-transit images through the two phantoms were also acquired in EPID from a non-modulated 6 MV beam when the gantry was rotated 360 degrees; the image through the centered phantom simulates calculated image. While the current study is a feasibility study, in reality our computational EPID model can be applicable in providing accurate transit image from MC simulation. Changed MV HU values were reconstructed from the ratio between two EPID projection data, converted to KV HU values, and added to the planning CT, thereby reconstructing the on-treatment image of the patient limited to the irradiated region of the phantom. Results: The reconstructed image was compared with the reference image. Except for local HU differences>200 as a maximum, excellent agreement was found. The average difference across the entire image was 16.2 HU. Conclusion: We have demonstrated the feasibility of a method of reconstructing on-treatment images of a patient using EPID image and planning CT images. Further studies will include resolving the local HU differences and investigation on the dosimetry impact of the reconstructed image.

  10. Congenital salivary gland anlage tumor - in utero and postnatal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Radhakrishnan, Rupa; Calvo-Garcia, Maria A.; Koch, Bernadette L. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lim, Foong-Yen [Cincinnati Children' s Hospital Medical Center, Division of Pediatric Surgery, Cincinnati, OH (United States); Elluru, Ravindhra G. [Cincinnati Children' s Hospital Medical Center, Division of Pediatric Otolaryngology, Cincinnati, OH (United States)

    2015-03-01

    We present a case of an infant with congenital salivary gland anlage tumor, with fetal and postnatal imaging. To the best of our knowledge, this is the first case describing the in utero imaging findings of salivary gland anlage tumor. A fetal MRI was performed secondary to the clinical finding of polyhydramnios, which identified a nasopharyngeal mass. Because findings were concerning for airway obstruction, the fetus was delivered by ex utero intrapartum treatment (EXIT) to airway procedure. A postnatal CT confirmed the findings of the fetal MRI. The lesion was resected when the baby was 4 days old and recovery was uneventful. (orig.)

  11. Diagnosis of pancreatic tumors by spiral angio CT

    International Nuclear Information System (INIS)

    Miura, Kohi; Nakao, Norio; Takayasu, Yukio; Okawa, Tomohisa

    1995-01-01

    Spiral angio were performed with injection of 30 ml of contrast material at a rate of 1 ml/sec with a scan delay of 6 sec through catheter into the celiac artery while the blood flow of the superior mesenteric artery (SMA) was occluded by the inflated balloon catheter. Spiral CT scans were obtained using Somatom Plus (Siemens). Parameter for spiral CT were 24-sec acquisition time, 5 mm collimation, 5 mm/sec table incrementation. Reconstructions were performed every 5 mm. Pancreatic cancers were characteristically depicted with spiral angio CT as hypodensity relative to normal enhanced pancreatic parenchyma. On dynamic angio CT studies performed in pancreatic cancers, the area of cancer and normal parenchyma had maximum level of enhancement at 10-15 sec after injection of contrast material via catheter into the celiac, and there was no difference in enhancement between tumor and normal parenchyma. On the other hand, the lesions of cancer were revealed as hypodensity with spiral angio CT. In case of chronic pancreatitis, the enhancement of the entire pancreas obtained with spiral angio CT was homogeneous. Insulinoma in the tail of pancreas was detected by spiral angio CT but was not detected by both selective angiography and conventional CT. Three-dimensional (3-D) rendering spiral angio CT data shows the extent of vascular involvement by pancreatic cancer and provides useful information for surgical planning. Spiral angio CT is the most useful procedure for diagnosis of pancreatic tumor. (author)

  12. Diagnostic value of FDG PET-CT for detecting primary breast malignancy: comparison with other image modalities and histopathologic correlation

    International Nuclear Information System (INIS)

    Jung, Na Young; Lee, Jae Hee; Kim, Chung Ho; Yoo, Ie Ryung; Kim, Sung Hoon; Chung, Yong An; Sohn, Hyung Sun; Chung, Soo Kyo; Jung, Sang Seol

    2004-01-01

    To compare the diagnostic value of 18F-FDG PET-CT in detecting the primary breast malignancy with other imaging modalities and to determine whether detectability of PET-CT depends on any factors such as size, differentiation, or nuclear grade of tumor. We evaluated pathologically proven 66 lesions in 61 patients (26-74 years, mean 46.9) who underwent preoperative PET-CT. Other imaging modalities were also evaluated: mammography in 58, US in 49 and MRI in 16. PET-CT images were visually evaluated and peak and mean SUV of mass were measured. For mammography and US, category 4 and 5 lesions as positive, and category 0-3 lesions as negative. For MRI, we used morphology and dynamic kinetic curve data based scoring system; sum of the scores higher than 10 as positive. Sensitivities of each modality were obtained. We analyzed PET-CT positive and negative groups in relation to size, SUV, differentiation and nuclear grade of tumors using paired t-test and Fisher's exact test. 65 among 66 were malignant lesions: invasive ductal carcinoma (n=56), ductal carcinoma in situ (n=3), tubular carcinoma (n=1), medullary carcinoma(n=3), mucinous carcinoma(n=1) and malignant fibrous histiocytoma (n=1). One lesion was benign lesion. Sensitivities of PET-CT, mammography, US, and MRI for detecting malignant mass were 86.2%, 80.7%, 100% and 94.1% respectively. SUV(P) and SUV(M) in PET-CT positive group (5.28±3.24 and 3.56±2.24) was significantly higher than that of PET CT negative group (1.96±0.35 and 1.46±0.44) [p<0.0001 for both]. The size of the primary mass in PET-CT positive group (2.66±1.47) was significantly larger than that in PET-CT negative group (1.52±0.57) (p=0.0002). The nuclear grade and tumor differentiation were not significantly different between two groups. The sensitivity of the FDG PET-CT in detecting primary breast cancer is lower than those of other imaging modalities. The detectability of the FDG PET-CT might be degraded when the tumor is small in size

  13. [Imaging manifestations and pathologic basis for hepatic capsular retraction syndrome caused by benign and malignant liver tumors].

    Science.gov (United States)

    Ou, Youkuan; Xiao, Enhua; Shang, Quanliang; Chen, Juan

    2015-10-01

    To investigate the imaging manifestations of CT, MRI and pathological basis for hepatic capsular retraction syndrome caused by benign and malignant liver tumors.
 CT or MRI images and pathological features for hepatic capsular retraction syndrome were retrospectively analyzed in 50 patients with benign and malignant liver tumors. Picture archive and communication system (PACS) was used to observe and compare the morphology, size, width, depth, edge of the capsular retraction and the status of liquid under the liver capsule. The structure, differentiation and proliferation of the tumor were analyzed under the microscope.
 There were malignant liver tumors in 44 patients and benign tumor in 6 patients. The smooth or rough for the edge of capsular retraction was significant difference between the benign tumors and the malignant tumors with three differentiated grades (all PBenign and malignant hepatic tumors may appear capsule retraction syndrome, but there are morphological differences between them. The differences are closely related with the lesion size, differentiated degree of tumor and fibrous tissue proliferation.

  14. Bone tumors

    International Nuclear Information System (INIS)

    Unni, K.K.

    1988-01-01

    This book contains the proceedings on bone tumors. Topics covered include: Bone tumor imaging: Contribution of CT and MRI, staging of bone tumors, perind cell tumors of bone, and metastatic bone disease

  15. Muscle metastases: ultrasound and CT scan imaging in nine cases. Report on 9 cases

    International Nuclear Information System (INIS)

    Folinais, D.; Cluzel, Ph.; Blangy, S.; Sibert, A.; David, M.; Benacerraf, R.

    1988-01-01

    Clinical, ultrasound and CT scan examinations were carried out in 9 patients with secondary muscle lesions. All muscles can be affected but there was a marked predominance of psoas lesions (6 of the 9 cases). Two contrasting clinical pictures are seen. Secondary muscle tumors can occur during evolution of a known treated cancer (5 of the 9 cases), revealed usually by large, rarely painful, mass. CT scan imaging shows an heterogeneous mass taking up contrast and often partially necrotic, the lesions appearing hypoechogenic or heterogeneous on ultrasound exmination. Certain lesions can be totally necrotic. In some cases (4 of the 9 patients) the muscle metastases revealed the presence of a tumor. Symptomatology may be atypical and lead to a delay in diagnosis. Fine needle puncture biopsy can detect the secondary origin of the muscle lesion and also the primary tumor site (4 out of 9 cases), bronchopulmonary and colon cancer predominating. Images are however non-specific and in the absence of NMR imaging the muscle or lymph node metastases can be confused, although this has no practic consequences since treatment is identical [fr

  16. Evaluation of (68)Ga-DOTA-TOC PET/CT for the detection of duodenopancreatic neuroendocrine tumors in patients with MEN1.

    Science.gov (United States)

    Morgat, Clément; Vélayoudom-Céphise, Fritz-Line; Schwartz, Paul; Guyot, Martine; Gaye, Delphine; Vimont, Delphine; Schulz, Jürgen; Mazère, Joachim; Nunes, Marie-Laure; Smith, Denis; Hindié, Elif; Fernandez, Philippe; Tabarin, Antoine

    2016-07-01

    Somatostatin receptor scintigraphy with (111)In-pentetreotide (SRS) is used to detect duodenopancreatic neuroendocrine tumors (dpNETs) in multiple endocrine neoplasia type 1 (MEN1). However, SRS has limited sensitivity for this purpose. Positron emission tomography/computed tomography (PET/CT) with (68)Ga-DOTA-TOC has a higher rate of sporadic dpNETs detection than SRS but there is little data for dpNETs detection in MEN1. To compare the performances of (68)Ga-DOTA-TOC PET/CT, SRS and contrast-enhanced computed tomography (CE-CT) to diagnose dpNETs in MEN1. Single-institution prospective comparative study Nineteen consecutive MEN1 patients (aged 47 ± 13 years) underwent (68)Ga-DOTA-TOC PET/CT, SRS, and CE-CT within 2 months in random order. Blinded readings of images were performed separately by experienced physicians. Unblinded analysis of CE-CT, combined with additional magnetic resonance imaging, endoscopic-ultrasound, (18)F-2-fluoro-deoxy-D-glucose ((18)F-FDG) PET/CT or histopathology results served as reference standard for dpNETs diagnosis. The sensitivity of (68)Ga-DOTA-TOC PET/CT, SRS, and CE-CT was 76, 20, and 60 %, respectively (p TOC PET/CT. (68)Ga-DOTA-TOC PET/CT detected lesions of smaller size than SRS (10.7 ± 7.6 and 15.2 ± 5.9 mm, respectively, p TOC PET/CT included small dpNETs (TOC PET/CT identified extra-abdominal MEN1-related tumors including one neuroendocrine thymic carcinoma identified by the three imaging procedures, one bronchial carcinoid undetected by CE-CT and three meningiomas undetected by SRS. Owing to higher diagnostic performance, (68)Ga-DOTA-TOC PET/CT (or alternative (68)Ga-labeled somatostatin analogues) should replace (111)In-pentetreotide in the investigation of MEN1 patients.

  17. Comparative Oncology: Evaluation of 2-Deoxy-2-[18F]fluoro-D-glucose (FDG Positron Emission Tomography/Computed Tomography (PET/CT for the Staging of Dogs with Malignant Tumors.

    Directory of Open Access Journals (Sweden)

    Stefanie M F Seiler

    Full Text Available 2-Deoxy-2-[18F]fluoro-D-glucose PET/CT is a well-established imaging method for staging, restaging and therapy-control in human medicine. In veterinary medicine, this imaging method could prove to be an attractive and innovative alternative to conventional imaging in order to improve staging and restaging. The aim of this study was both to evaluate the effectiveness of this image-guided method in canine patients with spontaneously occurring cancer as well as to illustrate the dog as a well-suited animal model for comparative oncology.Ten dogs with various malignant tumors were included in the study and underwent a whole body FDG PET/CT. One patient has a second PET-CT 5 months after the first study. Patients were diagnosed with histiocytic sarcoma (n = 1, malignant lymphoma (n = 2, mammary carcinoma (n = 4, sertoli cell tumor (n = 1, gastrointestinal stromal tumor (GIST (n = 1 and lung tumor (n = 1. PET/CT data were analyzed with the help of a 5-point scale in consideration of the patients' medical histories.In seven of the ten dogs, the treatment protocol and prognosis were significantly changed due to the results of FDG PET/CT. In the patients with lymphoma (n = 2 tumor extent could be defined on PET/CT because of increased FDG uptake in multiple lymph nodes. This led to the recommendation for a therapeutic polychemotherapy as a treatment. In one of the dogs with mammary carcinoma (n = 4 and in the patient with the lung tumor (n = 1, surgery was cancelled due to the discovery of multiple metastasis. Consequently no treatment was recommended.FDG PET/CT offers additional information in canine patients with malignant disease with a potential improvement of staging and restaging. The encouraging data of this clinical study highlights the possibility to further improve innovative diagnostic and staging methods with regard to comparative oncology. In the future, performing PET/CT not only for staging but also in therapy control could offer a

  18. Magnetic resonance imaging of primary intracranial tumors: a review

    International Nuclear Information System (INIS)

    Holland, B.A.; Brant-Zawadzki, M.; Norman, D.; Newton, T.H.

    1985-01-01

    The experience in magnetic resonance (MR) imaging of primary intracranial neoplasia at University of California, San Francisco is reviewed. Seventy patients have been evaluated by MR and computerized tomography (CT). MR scans were performed using a multi-slice spin echo technique with a long pulse repetition time (TR = 2000 msec), and long echo sampling delay (TE = 56 msec). This method was most sensitive in differentiating normal gray and white matter and in detecting both cerebral edema and abnormal tissue with prolonged T 2 characteristics. More sensitive to slight alterations in normal tissue, MR may detect a focal lesion in cases in which CT shows only mass effect. Moreover, MR may demonstrate more thoroughly the extent of tumor infiltration and broaden the characterization of abnormal tissue. Posterior fossa and brainstem anatomy are invariably better depicted by MR. The major limitations of MR include its inability to detect foci of tumor calcification, demonstrate the severity of bone destruction, or reliably distinguish tumor nidus from surrounding edema

  19. Intracranial solitary fibrous tumor: Imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic, E-mail: fredclare5@msn.com [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France); Bonneville, Fabrice [Department of Neuroradiology, Hopital Rangueil, Toulouse University Hospital, 31000 Toulouse (France); Rousseau, Audrey [Department of Neuropathology, Pitie-Salpetriere Hospital (France); Galanaud, Damien [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France); Kujas, Michele [Department of Neuropathology, Pitie-Salpetriere Hospital (France); Naggara, Olivier [Department of Neuroradiology, St Anne Hospital, 75014 Paris (France); Cornu, Philippe [Department of Neurosurgery, Pitie-Salpetriere Hospital (France); Chiras, Jacques [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France)

    2011-11-15

    Objective: To study the neuroimaging features of intracranial solitary fibrous tumors (ISFTs). Materials and methods: Retrospective study of neuroimaging features of 9 consecutive histopathologically proven ISFT cases. Location, size, shape, density, signal intensity and gadolinium uptake were studied at CT and MRI. Data collected from diffusion-weighted imaging (DWI) (3 patients), perfusion imaging and MR spectroscopy (2 patients), and DSA (4 patients) were also analyzed. Results: The tumors most frequently arose from the intracranial meninges (7/9), while the other lesions were intraventricular. Tumor size ranged from 2.5 to 10 cm (mean = 6.6 cm). They presented multilobular shape in 6/9 patients. Most ISFTs were heterogeneous (7/9) with areas of low T2 signal intensity that strongly enhanced after gadolinium administration (6/8). Erosion of the skull was present in about half of the cases (4/9). Components with decreased apparent diffusion coefficient were seen in 2/3 ISFTs on DWI. Spectroscopy revealed elevated peaks of choline and myo-inositol. MR perfusion showed features of hyperperfusion. Conclusion: ISFT should be considered in cases of extra-axial, supratentorial, heterogeneous, hypervascular tumor. Areas of low T2 signal intensity that strongly enhance after gadolinium injection are suggestive of this diagnosis. Restricted diffusion and elevated peak of myo-inositol may be additional valuable features.

  20. Computed tomography (CT) of cervical lymph nodes in patients with oral cancer. Comparison of low-attenuation areas in lymph nodes on CT images with pathological findings

    International Nuclear Information System (INIS)

    Fukunari, Fumiko; Okamura, Kazuhiko; Yuasa, Kenji; Kagawa, Toyohiro; Zeze, Ryousuke

    2008-01-01

    The objective of this study was to clarify the histopathological features of low-attenuation areas in computed tomography (CT) images of cervical metastatic and benign lymph nodes in patients with oral squamous cell carcinoma (SCC). CT images of 230 lymph nodes from 37 patients with oral SCC were classified into four categories and compared with histopathological findings. Metastatic lymph nodes were evaluated in terms of focal necrosis, keratinization, fibrous tissue, and the proportion of the lymph node showing focal necrosis. Benign lymph nodes were evaluated in terms of adipose tissue, follicular hyperplasia, sinus histiocytosis, hyperemia, focal hemorrhaging, and the amount of adipose tissue. Histopathologically, all 13 metastatic lymph nodes with rim enhancement on CT images included focal necrosis. However, most of the lymph nodes showed no focal necrosis. In addition, tumor cells, keratinization, and fibrous tissue were observed in the lymph nodes. Of the 26 metastatic lymph nodes with a heterogeneous appearance on CT images, four did not show focal necrosis. These lymph nodes showed keratinization or accumulation of lymph fluid. Histopathologically, 20 of 24 benign lymph nodes with a heterogeneous appearance on CT images (83.3%) had accompanying adipose tissue. Focal necrosis was the most important factor contributing to low attenuation in metastatic lymph nodes. However, other factors, such as tumor cells, keratinization, fibrous tissue, and accumulation of lymph fluid, also contributed. In benign lymph nodes, the presence of adipose tissue was a contributing factor in low-attenuation areas, as was focal hemorrhaging. (author)

  1. Imaging of bone tumors for the musculoskeletal oncologic surgeon.

    Science.gov (United States)

    Errani, C; Kreshak, J; Ruggieri, P; Alberghini, M; Picci, P; Vanel, D

    2013-12-01

    The appropriate diagnosis and treatment of bone tumors requires close collaboration between different medical specialists. Imaging plays a key role throughout the process. Radiographic detection of a bone tumor is usually not challenging. Accurate diagnosis is often possible from physical examination, history, and standard radiographs. The location of the lesion in the bone and the skeleton, its size and margins, the presence and type of periosteal reaction, and any mineralization all help determine diagnosis. Other imaging modalities contribute to the formation of a diagnosis but are more critical for staging, evaluation of response to treatment, surgical planning, and follow-up.When necessary, biopsy is often radioguided, and should be performed in consultation with the surgeon performing the definitive operative procedure. CT is optimal for characterization of the bone involvement and for evaluation of pulmonary metastases. MRI is highly accurate in determining the intraosseous extent of tumor and for assessing soft tissue, joint, and vascular involvement. FDG-PET imaging is becoming increasingly useful for the staging of tumors, assessing response to neoadjuvant treatment, and detecting relapses.Refinement of these and other imaging modalities and the development of new technologies such as image fusion for computer-navigated bone tumor surgery will help surgeons produce a detailed and reliable preoperative plan, especially in challenging sites such as the pelvis and spine. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Visualization of tumor blockage and rerouting of lymphatic drainage in penile cancer patients by use of SPECT/CT.

    Science.gov (United States)

    Leijte, Joost A P; van der Ploeg, Iris M C; Valdés Olmos, Renato A; Nieweg, Omgo E; Horenblas, Simon

    2009-03-01

    The reliability of sentinel node biopsy is dependent on the accurate visualization and identification of the sentinel node(s). It has been suggested that extensive metastatic involvement of a sentinel node can lead to blocked inflow and rerouting of lymph fluid to a "neo-sentinel node" that may not yet contain tumor cells, causing a false-negative result. However, there is little evidence to support this hypothesis. Recently introduced hybrid SPECT/CT scanners provide both tomographic lymphoscintigraphy and anatomic detail. Such a scanner enabled the present study of the concept of tumor blockage and rerouting of lymphatic drainage in patients with palpable groin metastases. Seventeen patients with unilateral palpable and cytologically proven metastases in the groin underwent bilateral conventional lymphoscintigraphy and SPECT/CT before sentinel node biopsy of the contralateral groin. The pattern of lymphatic drainage in the 17 palpable groin metastases was evaluated for signs of tumor blockage or rerouting. On the CT images, the palpable node metastases could be identified in all 17 groins. Four of the 17 palpable node metastases (24%) showed uptake of radioactivity on the SPECT/CT images. In 10 groins, rerouting of lymphatic drainage to a neo-sentinel node was seen; one neo-sentinel node was located in the contralateral groin. A complete absence of lymphatic drainage was seen in the remaining 3 groins. The concept of tumor blockage and rerouting was visualized in 76% of the groins with palpable metastases. Precise physical examination and preoperative ultrasound with fine-needle aspiration cytology may identify nodes with considerable tumor invasion at an earlier stage and thereby reduce the incidence of false-negative results.

  3. Synthesis and Bioevaluation of Iodine-131 Directly Labeled Cyclic RGD-PEGylated Gold Nanorods for Tumor-Targeted Imaging

    Directory of Open Access Journals (Sweden)

    Yingying Zhang

    2017-01-01

    Full Text Available Introduction. Radiolabeled gold nanoparticles play an important role in biomedical application. The aim of this study was to prepare iodine-131 (131I-labeled gold nanorods (GNRs conjugated with cyclic RGD and evaluate its biological characteristics for targeted imaging of integrin αvβ3-expressing tumors. Methods. HS-PEG(5000-COOH molecules were applied to replace CTAB covering the surface of bare GNRs for better biocompatibility, and c(RGDfK peptides were conjugated onto the carboxyl terminal of GNR-PEG-COOH via EDC/NHS coupling reactions. The nanoconjugate was characterized, and 131I was directly tagged on the surface of GNRs via AuI bonds for SPECT/CT imaging. We preliminarily studied the characteristics of the probe and its feasibility for tumor-targeting SPECT/CT imaging. Results. The [131I]GNR-PEG-cRGD probe was prepared in a simple and rapid manner and was stable in both PBS and fetal bovine serum. It targeted selectively and could be taken up by tumor cells mainly via integrin αvβ3-receptor-mediated endocytosis. In vivo imaging, biodistribution, and autoradiography results showed evident tumor uptake in integrin αvβ3-expressing tumors. Conclusions. These promising results showed that this smart nanoprobe can be used for angiogenesis-targeted SPECT/CT imaging. Furthermore, the nanoprobe possesses a remarkable capacity for highly efficient photothermal conversion in the near-infrared region, suggesting its potential as a multifunctional theranostic agent.

  4. Diffuse and focal presentations of brainstem tumors in children: the images and the prognostic value

    International Nuclear Information System (INIS)

    Menor, F.; Canete, A.; Romero, M. J.; Trilles, L.; Carvajal, E.; Marti-Bonmati, L.

    2000-01-01

    To determine whether the presentation of brainstem tumors as diffuse or focal lesions showed any prognostic value in children. A retrospective review was carried out of the neuroradiological findings in 43 children with brainstem tumors, all of whom underwent computed tomography (CT) and 31 of whom underwent magnetic resonance (MR). The diffuse tumors (n=20) were all located in the pons, spreading to mesencephalon in 6 cases and to medulla oblongata in 1, and exhibiting exophytic growth, preferentially to the prepontine cistern. They presented homogeneous low attenuation in CT (90%) and decrease/increased signal intensity in T1/T2-weighted MR images (91.6%). Contrast uptake was observed in 20% of cases, with agreement between CT and MR. The patients showed a good initial response to treatment (70%), a high rate of relapse (80%) and a 5-year survival of 12%. The focal tumors were located in the pons (11 cases, spreading to the medulla oblongata in 2), mesencephalon (11 cases, 9 tectal and 2 peduncular) and medulla oblongata (1 case), and exhibited exophytic growth predominantly to the pontocerebellar junction and to the cerebellar peduncles. They showed a certain tendency toward heterogeneity (21.7%), toward isoattenuation in CT (47.8%) and isointensity in T1-weighted MR images (26.3%). CT showed a rate of tumor uptake of 26%, while the rate of contrast iptake was 58% MR. Fifty percent of these lesions responded well to therapy, with a recurrence rate of 28% and 4-year survival of 63%. Neuroimaging helps to define two basic patterns in brainstem tumors that play a role in prognosis. The diffuse tumor, which characteristically shows a good initial response to therapy, has a worse prognosis, probably reflecting its histological aggressiveness. (Author) 21 refs

  5. Evolving role of 18F-FDG-PET/CT for the body tumor and metastases in pediatrics

    International Nuclear Information System (INIS)

    Chen Zhengguang; Li Xiaozhen; Li Fang; Ouyang Qiaohong; Yu Tong

    2010-01-01

    18 F-FDG-positron emission tomography-computerized tomography ( 18 F-FDG-PET/CT) scan is an important imaging tool which may provide both functional and anatomical information in a single diagnostic test. It has the potential to be a valuable tool in the noninvasive evaluation and monitoring of pediatric tumors including the metastases because 18 fluorodeoxyglucose ( 18 F-FDG) is a glucose analogue that concentrates in areas of active metabolic activity. This review provides an update on functional and metabolic imaging approaches for assessment and management of the body tumor and metastases in pediatrics using a combined whole body 18 F-FDG-PET/CT scanners. We discuss the benefits include improved pediatric patients' outcome facilitated by staging and monitoring of disease and better treatment planning. It is worth to concern the preparation of children undergoing PET studies and radiation dosimetry and its implications for family and caregivers. It is important to consider the normal distribution of 18 FDG in children, common variations of the normal distribution. We show some of our cases that most tumors in children accumulate and retain FDG, allowing high-quality images of their distribution and pathophysiology either at the primary site as well as in the areas of metastatic disease.

  6. Present and future of the hybrid imaging method SPECT/CT

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2013-01-01

    Full text: Introduction: Based on the data in the literature and on our 4 year clinical experience applied for the first time in our country hybrid imaging - single photon emission tomography combined with computed tomography (SPECT / CT) it is clear that to obtain comprehensive information about the function and structure of the studied organ; the time for the diagnosis and thus the start of adequate treatment become shorter. The resulting scintigraphic image is with better quality due to CT correction of ‘diffusion’ gamma radiation, which leads to greater diagnostic accuracy. What you will learn: complex imaging method is used mainly in the field of endocrinology, cardiology, oncology, orthopedics, pulmology, neurology, and neurosurgery. It can be prove a given disease by visualization and localization of the organ lesions and determine the stage of the tumor process, to plan the type of subsequent treatment, to follow the effects of the therapy, and to predict the effect of an interventional or miniinvasive surgical procedure. Discussion: The result of the application of the hybrid imaging method is a change in the interpretation of more than half of the studied patients and in the treatment in more than a quarter of them. Conclusion: The clinical indications for SPECT/CT, and evidence of increased diagnostic accuracy compared with self- administered scintigraphic or CT methods are continuous expanded

  7. Functional imaging of larynx via 256-Slice Multi-Detector Computed Tomography in patients with laryngeal tumors: A faster, better and more reliable pre-therapeutic evaluation

    International Nuclear Information System (INIS)

    Celebi, Irfan; Basak, Muzaffer; Ucgul, Ayhan; Yildirim, Hakan; Oz, Aysel; Vural, Cetin

    2012-01-01

    Objective: To determine the clinical utility of using dynamic maneuvers during imaging of larynx via 256-Slice Multi-Detector Computed Tomography in the pre-therapeutic evaluation of laryngeal tumors. Materials and methods: A total of 27 patients (7 women, 20 men; aged 53–76 years) diagnosed with laryngeal squamous cell carcinoma were evaluated pre-therapeutically via contrast enhanced axial CT scans during consecutive phases of phonation (PP), inspiration (IP) and Valsalva maneuver (VP). Results: In 2 of 5 patients diagnosed with T1a glottic tumor, scans obtained during VP and PP were normal while the CT scans obtained during IP clearly showed a mass. In all patients (27/27) PP provided visualization of the ventricle, on coronal plane images and the pyriform sinus apices, on axial plane images. Involvement of the anterior commissure was best assessable on axial plane IP images (sensitivity 93%, specificity 92%). In cases of stage T1–T3 tumors use of dynamic maneuvers during laryngeal CT imaging showed the location and extension of the tumor better than the single phase CT scans did. We did not find a significant improvement in the pre-therapeutic evaluation in stage T4 tumors. Conclusion: Providing markedly clearer and more detailed evaluation of mucosal surfaces and deep structures of the larynx and mobility of the cords than do conventional scans, use of dynamic laryngeal maneuvers during laryngeal CT imaging seems to be an useful alternative in the pre-therapeutic assessment of laryngeal tumors.

  8. Impact of SPECT/CT in imaging inflammation and infection; Wertigkeit der SPECT/CT fuer die nuklearmedizinische Entzuendungsdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinikum Bremen-Mitte, Bremen (Germany). Klinik fuer Nuklearmedizin; Kuwert, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik

    2011-03-15

    Even today infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Several techniques in nuclear medicine significantly aid infection diagnosis, including triple-phase bone scanning, {sup 18}F-FDG-PET and imaging with {sup 111}In-oxine-, {sup 99m}Tc-HMPAO-labeled leukocytes. Each radiopharmaceutical has specific advantages and disadvantages that makes it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immuno-compromised patients). However, their clinical applications may be limited by the relatively low spatial resolution and the lack of anatomic landmarks of a highly specific tracer with only scarce background uptake to use as a framework for orientation. Anatomic imaging modalities such as CT provide a high-quality assessment of structural abnormalities related to infection, but these structural abnormalities may be unspecific. Furthermore, to detect infection before anatomical changes are present, functional imaging could have some advantages over anatomical imaging. Scintigraphic studies have demonstrated high sensitivity and specificity to an infectious process. Diagnosis and precise delineation of infection may be challenging in certain clinical scenarios, rendering decisions concerning further patient management difficult. The SPECT/CT-technology combines the acquisition of SPECT and CT data with the same imaging device enabling perfect overlay of anatomical and functional images. SPECT/CT imaging data has been shown to be beneficial for many clinical settings such as indeterminate findings in bone scintigraphy, orthopaedic disorders, endocrine, and neuroendocrine tumors. Therefore

  9. Highly sensitive detection of the soft tissues based on refraction contrast by in-plane diffraction-enhanced imaging CT

    International Nuclear Information System (INIS)

    Yuasa, Tetsuya; Hashimoto, Eiko; Maksimenko, Anton; Sugiyama, Hiroshi; Arai, Yoshinori; Shimao, Daisuke; Ichihara, Shu; Ando, Masami

    2008-01-01

    We discuss the recently proposed computed tomography (CT) technique based on refractive effects for biomedical use, which reconstructs the in-plane refractive-index gradient vector field in a cross-sectional plane of interest by detecting the angular deviation of the beam, refracted by a sample, from the incident beam, using the diffraction-enhanced imaging (DEI) method. The CT has advantages for delineating biological weakly absorbing soft tissues over the conventional absorption-contrast CT because of the use of phase sensitive detection. The paper aims to define the imaging scheme rigidly and to demonstrate its efficacy for non-destructive measurement of biomedical soft-tissue samples without imaging agent. We first describe the imaging principle of in-plane DEI-CT from the physico-mathematical viewpoints in detail, and investigate what physical quantities are extracted from the reconstructed images. Then, we introduce the imaging system using the synchrotron radiation as a light source, constructed at beamline BL-14B in KEK, Japan. Finally, we demonstrate the advantage of the refraction-based image for non-destructive analysis of biological sample by investigating the image of human breast cancer tumors obtained using the imaging system. Here, the refraction- and the apparent absorption-based images obtained simultaneously by the in-plane DEI-CT are compared. Also, the conventional absorption-based image obtained using micro-computed tomography (μCT) imaging system is compared with them. Thereby, it is shown that the refraction contrast much more sensitively delineates the soft tissues than the absorption contrast. In addition, the radiologic-histologic correlation study not only validates the efficacy for imaging soft tissues, but also produces the potential that the pathological inspection for the breast cancer tumors may be feasible non-destructively

  10. Image-guided radiofrequency ablation of Bosniak category III or IV cystic renal tumors: initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan; Kim, Chan Kyo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea); Lee, Hyun Moo [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea)

    2008-07-15

    The purpose of this study was to assess the efficacy of image-guided radiofrequency (RF) ablation of cystic renal tumors. Between November 2005 and August 2007, computed tomography (CT) or ultrasound-guided RF ablation was performed in nine patients with 14 Bosniak category III (n = 5) or IV (n = 9) cystic renal tumors using an internally cooled RF ablation system. We evaluated the number of sessions, cycles and duration of energy application, treatment results, lesion size change, and complications. Together the cystic renal tumors required 15 sessions and 23 cycles of energy application. The duration of energy application per one tumor ablation ranged from 1 to 12 min (mean 6 min). The last follow-up CT indicated complete coagulation of 14/14 (100%) lesions. None of these tumors had recurred within 1-19 months (mean 8 months). The maximum diameter of the cystic renal tumors was significantly reduced from 2.5 {+-} 0.6 cm before ablation to 1.7 {+-} 0.7 cm at the last follow-up CT (P < 0.01). Complications were pneumothorax (n = 2), inguinal paresthesia (n = 1), and arteriovenous fistula (n = 1). Image-guided RF ablation is an effective treatment for Bosniak category III or IV cystic renal tumors, which might need relatively shorter duration of energy application than purely solid renal tumors of the same size. (orig.)

  11. Image-guided radiofrequency ablation of Bosniak category III or IV cystic renal tumors: initial clinical experience

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Chan Kyo; Lee, Hyun Moo

    2008-01-01

    The purpose of this study was to assess the efficacy of image-guided radiofrequency (RF) ablation of cystic renal tumors. Between November 2005 and August 2007, computed tomography (CT) or ultrasound-guided RF ablation was performed in nine patients with 14 Bosniak category III (n = 5) or IV (n = 9) cystic renal tumors using an internally cooled RF ablation system. We evaluated the number of sessions, cycles and duration of energy application, treatment results, lesion size change, and complications. Together the cystic renal tumors required 15 sessions and 23 cycles of energy application. The duration of energy application per one tumor ablation ranged from 1 to 12 min (mean 6 min). The last follow-up CT indicated complete coagulation of 14/14 (100%) lesions. None of these tumors had recurred within 1-19 months (mean 8 months). The maximum diameter of the cystic renal tumors was significantly reduced from 2.5 ± 0.6 cm before ablation to 1.7 ± 0.7 cm at the last follow-up CT (P < 0.01). Complications were pneumothorax (n = 2), inguinal paresthesia (n = 1), and arteriovenous fistula (n = 1). Image-guided RF ablation is an effective treatment for Bosniak category III or IV cystic renal tumors, which might need relatively shorter duration of energy application than purely solid renal tumors of the same size. (orig.)

  12. Ga-67 tumor scan in malignant diffuse mesothelioma. Comparison with CT and pathological findings

    International Nuclear Information System (INIS)

    Yoshida, Shoji; Fukumoto, Mitsutaka; Motohara, Tomofumi; Oobayashi, Kayoko; Takada, Yoshiki; Tsubota, Noriaki; Sashikata, Terumasa

    1999-01-01

    Malignant diffuse mesothelioma is characterized by more difficult diagnosis and worse prognosis than other pleural tumors. In the Department of Thoracic Surgery, Hyogo Medical Center for Adults, 11 patients underwent panpleuropneumonectomy for this disease between January, 1988 and March, 1993. In 7 of these cases, Ga-67 scans were obtained before the operation. To clarify the factors affecting Ga-67 uptake in the pleural tumor, we compared Ga-67 uptake on the involved side of the thorax with CT and the pathological findings of the tumor. Regarding the use of Ga-67 scan imaging for the diagnosis of this disease, a number of related findings must be considered, such as an encircled wide Ga-67 uptake in the thickened pleural involvement and a diffuse slight Ga-67 uptake on the affected side with very slight involvement of the pleura. When the involved pleural thickness was over 6 mm, a definite correlation was found between the degree of Ga-67 uptake and the macroscopic thickness of mesothelioma in resected specimens. Thickness of the pleura on CT images demonstrates the real tumor thickness in the case of thickened involvement but in the case of thin involvement the real thickness of active mesothelioma could not be identified. No definite correlation was found between the degree of Ga-67 uptake and the histological type, or among microscopic findings, such as the extent of tumor parenchyma, interstitial volume and tumor vascularity. Our results suggest that the Ga-67 scan is very useful for revealing the extent of pleural involvement, especially when this involvement is more than 6 mm thick. (author)

  13. Ga-67 tumor scan in malignant diffuse mesothelioma. Comparison with CT and pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shoji; Fukumoto, Mitsutaka [Kochi Medical School, Nankoku (Japan); Motohara, Tomofumi; Oobayashi, Kayoko; Takada, Yoshiki; Tsubota, Noriaki; Sashikata, Terumasa

    1999-02-01

    Malignant diffuse mesothelioma is characterized by more difficult diagnosis and worse prognosis than other pleural tumors. In the Department of Thoracic Surgery, Hyogo Medical Center for Adults, 11 patients underwent panpleuropneumonectomy for this disease between January, 1988 and March, 1993. In 7 of these cases, Ga-67 scans were obtained before the operation. To clarify the factors affecting Ga-67 uptake in the pleural tumor, we compared Ga-67 uptake on the involved side of the thorax with CT and the pathological findings of the tumor. Regarding the use of Ga-67 scan imaging for the diagnosis of this disease, a number of related findings must be considered, such as an encircled wide Ga-67 uptake in the thickened pleural involvement and a diffuse slight Ga-67 uptake on the affected side with very slight involvement of the pleura. When the involved pleural thickness was over 6 mm, a definite correlation was found between the degree of Ga-67 uptake and the macroscopic thickness of mesothelioma in resected specimens. Thickness of the pleura on CT images demonstrates the real tumor thickness in the case of thickened involvement but in the case of thin involvement the real thickness of active mesothelioma could not be identified. No definite correlation was found between the degree of Ga-67 uptake and the histological type, or among microscopic findings, such as the extent of tumor parenchyma, interstitial volume and tumor vascularity. Our results suggest that the Ga-67 scan is very useful for revealing the extent of pleural involvement, especially when this involvement is more than 6 mm thick. (author)

  14. NaF18-PET/CT imaging of second hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Win, Aung Zaw; Aparici, Carina Mari [San Francisco VA Medical Center, San Franciso (United States)

    2015-12-15

    The patient was a 59-year-old man with a history of hypertension and end-stage renal disease for 14 years. An NaF-18 positron emission tomography/CT bone scan was ordered to rule out osteosarcoma or other possible bone malignancies. A lesion representing a brown tumor was observed on the left femoral shaft. The incidence of ESRD is about 400 cases per million in the United States and it has risen fastest in older individuals. This is the second paper to report the use of NaF18-PET/CT to image secondary hyperparathyroidism, osteomalacia, mixed renal ostedystrophy and adyanmic bone disease.

  15. NaF18-PET/CT imaging of second hyperparathyroidism

    International Nuclear Information System (INIS)

    Win, Aung Zaw; Aparici, Carina Mari

    2015-01-01

    The patient was a 59-year-old man with a history of hypertension and end-stage renal disease for 14 years. An NaF-18 positron emission tomography/CT bone scan was ordered to rule out osteosarcoma or other possible bone malignancies. A lesion representing a brown tumor was observed on the left femoral shaft. The incidence of ESRD is about 400 cases per million in the United States and it has risen fastest in older individuals. This is the second paper to report the use of NaF18-PET/CT to image secondary hyperparathyroidism, osteomalacia, mixed renal ostedystrophy and adyanmic bone disease

  16. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  17. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  18. Automatic block-matching registration to improve lung tumor localization during image-guided radiotherapy

    Science.gov (United States)

    Robertson, Scott Patrick

    To improve relatively poor outcomes for locally-advanced lung cancer patients, many current efforts are dedicated to minimizing uncertainties in radiotherapy. This enables the isotoxic delivery of escalated tumor doses, leading to better local tumor control. The current dissertation specifically addresses inter-fractional uncertainties resulting from patient setup variability. An automatic block-matching registration (BMR) algorithm is implemented and evaluated for the purpose of directly localizing advanced-stage lung tumors during image-guided radiation therapy. In this algorithm, small image sub-volumes, termed "blocks", are automatically identified on the tumor surface in an initial planning computed tomography (CT) image. Each block is independently and automatically registered to daily images acquired immediately prior to each treatment fraction. To improve the accuracy and robustness of BMR, this algorithm incorporates multi-resolution pyramid registration, regularization with a median filter, and a new multiple-candidate-registrations technique. The result of block-matching is a sparse displacement vector field that models local tissue deformations near the tumor surface. The distribution of displacement vectors is aggregated to obtain the final tumor registration, corresponding to the treatment couch shift for patient setup correction. Compared to existing rigid and deformable registration algorithms, the final BMR algorithm significantly improves the overlap between target volumes from the planning CT and registered daily images. Furthermore, BMR results in the smallest treatment margins for the given study population. However, despite these improvements, large residual target localization errors were noted, indicating that purely rigid couch shifts cannot correct for all sources of inter-fractional variability. Further reductions in treatment uncertainties may require the combination of high-quality target localization and adaptive radiotherapy.

  19. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    Science.gov (United States)

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  20. PET-CT imaging fusion in the assessment of head and neck carcinoma

    International Nuclear Information System (INIS)

    Santos, Denise Takehana dos; Chojniak, Rubens; Lima, Eduardo Nobrega Pereira; Cavalcanti, Marcelo Gusmao Paraiso

    2006-01-01

    Objective: The authors have established a methodological approach to evaluate head and neck squamous cell carcinoma aiming at identifying and distinguishing high metabolic activity inside the lesion, combining in a single examination, functional, metabolic and morphological data simultaneously acquired by means of different non-dedicated positron emission tomography (PET)-computed tomography (CT) device. Materials and Methods: The study population included 17 patients with head and neck squamous cell carcinoma submitted to a non-dedicated 18 F-FDG-PET imaging at Department of Diagnostic Imaging of Hospital do Cancer, Sao Paulo, SP, Brazil. CT and 18 F-FDG-PET images were simultaneously acquired in a non-dedicated device. The original data were transferred to an independent workstation by means of the Entegra 2 NT software to generate PET-CT imaging fusion. Results: The findings were defined as positive in the presence of a well defined focal area of increased radiopharmaceutical uptake in regions not related with the normal biodistribution of the tracer. Conclusion: The fusion of simultaneously acquired images in a single examination ( 18 F-FDGPET and CT) has allowed the topographic-metabolic mapping of the lesion as well as the localization of high metabolic activity areas inside the tumor, indicating recidivation or metastasis and widening the array of alternatives for radiotherapy or surgical planning. (author)

  1. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  2. Fluorescence-Guided Probes of Aptamer-Targeted Gold Nanoparticles with Computed Tomography Imaging Accesses for in Vivo Tumor Resection.

    Science.gov (United States)

    Li, Cheng-Hung; Kuo, Tsung-Rong; Su, Hsin-Jan; Lai, Wei-Yun; Yang, Pan-Chyr; Chen, Jinn-Shiun; Wang, Di-Yan; Wu, Yi-Chun; Chen, Chia-Chun

    2015-10-28

    Recent development of molecular imaging probes for fluorescence-guided surgery has shown great progresses for determining tumor margin to execute the tissue resection. Here we synthesize the fluorescent gold nanoparticles conjugated with diatrizoic acid and nucleolin-targeted AS1411 aptamer. The nanoparticle conjugates exhibit high water-solubility, good biocompatibility, visible fluorescence and strong X-ray attenuation for computed tomography (CT) contrast enhancement. The fluorescent nanoparticle conjugates are applied as a molecular contrast agent to reveal the tumor location in CL1-5 tumor-bearing mice by CT imaging. Furthermore, the orange-red fluorescence emitting from the conjugates in the CL1-5 tumor can be easily visualized by the naked eyes. After the resection, the IVIS measurements show that the fluorescence signal of the nanoparticle conjugates in the tumor is greatly enhanced in comparison to that in the controlled experiment. Our work has shown potential application of functionalized nanoparticles as a dual-function imaging agent in clinical fluorescence-guided surgery.

  3. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  4. Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry

    International Nuclear Information System (INIS)

    D'Souza, Warren D.; Kwok, Young; Deyoung, Chad; Zacharapoulos, Nicholas; Pepelea, Mark; Klahr, Paul; Yu, Cedric X.

    2005-01-01

    Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CT scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging

  5. Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    Science.gov (United States)

    Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro

    2017-09-01

    To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Observation of normal appearance and wall thickness of esophagus on CT images

    International Nuclear Information System (INIS)

    Xia Fan; Mao Jingfang; Ding Jinquan; Yang Huanjun

    2009-01-01

    Purpose: This study sought to observe the appearance of normal esophagus, measure and record the thickness of esophageal wall in order to offer reference for estimating esophageal wall abnormalities and delineating gross tumor target of esophageal carcinomas on CT images. Materials and methods: From September 2006 to February 2007, 110 consecutive CT films from adult patients without esophageal diseases were collected and studied. On CT images the entire esophagus was divided into cervical, thoracic, retrocardiac and intraabdominal segments. The appearance of esophagus was described when the esophagus contracted or dilated. Thickness of esophageal wall and diameters of esophageal cavities were measured by hard-copy reading with a magnifying glass. Age, sex and the thickness of subcutaneous fat of each patient were recorded. Results: It was observed that the esophagus presented both contracted and dilated status on CT images. In each segment there were certain portions of esophagus in complete contraction or dilatation. 47 images (42.7%) showed contracted esophagus in each segment available for measurement. The largest wall thickness when esophagus was in contraction and dilatation was 4.70 (95%CI: 4.44-4.95) mm and 2.11 (95%CI: 2.00-2.23) mm, respectively. When contracting, the intraabdominal esophagus was thicker than the cervical, thoracic and retrocardiac parts, and the average thickness was 5.68 (95%CI: 5.28-6.09) mm, 4.67 (95%CI: 4.36-4.86) mm, 4.56 (95%CI: 4.31-4.87) mm, and 4.05 (95%CI: 3.71-4.21) mm, respectively. When the esophagus was dilating, the average esophageal wall thickness was between 1.87 and 2.70 mm. The thickest part was cervical esophagus. Thickness of esophageal wall was larger in males than that of females (5.26 mm vs. 4.34 mm p < 0.001). Age and the thickness of subcutaneous fat had no significant impact on the thickness of esophageal wall (p-value was 0.056 and 0.173, respectively). Conclusion: The Observation of normal appearance and

  7. New developments in imaging: Sonography, cine-CT, MRI

    International Nuclear Information System (INIS)

    Otto, R.J.; Higgins, C.B.

    1987-01-01

    The book can be conveniently subdivided into three sections: the first on magnetic resonance imaging the second on cine-computed tomography and the third on advances in ultrasound (US). The MR imaging section includes two chapters: the first on indications for MR in abdominal disease (a cookbook layout of indications for MR imaging versus CT) and the second on MR imaging of the heart. There are also chapters on MR imaging and US in the pelvis, contrast agent principles, and a chapter on imaging renal tumors. The third section, on US, contains chapters on the liver and gastrointenstinal disease, interventional US sonography during neurosurgery, state-of-the-art echocardiography. Doppler flow imaging, contrast media for sonography, endometrial sonography, and high-resolution US in the first trimester. The final chapter is presented as a scientific paper rather than as a chapter in a book and has no illustrations

  8. The accuracy of CT and tumor markers in the detection of a recurrent ovarian carcinoma

    International Nuclear Information System (INIS)

    Wakabayashi, Yukari; Ishida, Jiro; Kotake, Fumio; Hirose, Masahiro; Kawana, Koji; Abe, Kimihiko; Amino, Saburo; Negishi, Yoshiyuki; Akiya, Kiyoshi

    1989-01-01

    Twenty-three patients previously diagnosed as having ovarian cancer were examined with both serum tumor markers (CA 125, CA 19-9, TPA, IAP, AFP) and a pelvic CT scan. The tumor markers predict the clinical outcome more accurately than the CT scan. Further, the tumor markers showed a clear correlation with the clinical course. But in one case, however, the tumor markers were seen to reduce below the normal level from chemotherapy, while the CT scan showed a tumor mass. Thus, both, a CT scan and tumor marker assays are felt to be indispensable for detecting the recurrence of an ovarian cancer. (author)

  9. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    Science.gov (United States)

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  10. The diagnostic role of abdominal CT imaging findings in adults intussusception: Focused on the vascular compromise

    International Nuclear Information System (INIS)

    Park, Sung Bin; Ha, Hyun Kwon; Kim, Ah Young; Lee, Seung Soo; Kim, Hye Jin; Park, Beom Jin; Jin, Yong Hyun; Park, Seong Ho; Kim, Kyoung Won

    2007-01-01

    Intussusception is defined as telescoping of one segment of the gastrointestinal tract into an adjacent one. Unlike that in children, adult intussusception is a relatively rare condition. More than 90% of patients with adult intussusception have been reported to have an organic cause, with benign or malignant tumors for accounting for approximately 65% of the cases. In general, the diagnosis is easily made by means of computed tomography (CT) or magnetic resonance (MR) imaging. The imaging appearance of a bowel-within-bowel configuration with or without contained fat and mesenteric vessels, is pathognomonic. As the intussusceptum enters into the intussuscipiens, the mesentery is carried forward and trapped between the overlapping layers of bowel. The twisting or severe constriction of the mesenteric vessels may result in vascular compromise with subsequent edematous thickening of the involved bowel. In these circumstances, ischemic necrosis may develop if timely intervention is not undertaken. Therefore, determination of the presence or absence of intestinal necrosis in intussusception is important in patient management. On CT, the presence of well-known diagnostic CT criteria for strangulated obstruction (especially severe engorgement or twisting of the mesenteric vessels) as well as evidence of loss of the layered pattern, accumulation of extraluminal fluid collection, and bowel perforation, may suggest the diagnosis of intestinal necrosis. CT and MR imaging are limited in determining the primary disease causing intussusception. However, CT and MR provide excellent pre-operative evaluation, including the possible extension and/or dissemination of a malignant tumor. CT and MR imaging may also be useful in suggesting the presence of vascular compromise

  11. Subperiosteal chondroma. Diagnostic value of CT scan imaging in two cases

    International Nuclear Information System (INIS)

    Lerais, J.M.; Auquier, F.; Baudrillard, J.C.; Durot, J.F.; Laugareil, P.; Wallays, C.; Lefort, G.; Daoud, S.; Gaillard, D.

    1988-01-01

    Results of CT scan exploration are reported in two cases of subperiosteal chondroma, one in a 4 year old child affecting the anterior tibial tuberosity the other in a 9 year old child involving the upper end of humerus. Data from CT scan imaging were undoubtedly superior to those of conventional radiography and appear to be characteristic of this benign cartilaginous tumor, greatly facilitating correlation between clinical, radiological and pathologic findings. The scanner should allow certain situations to be dedramatized and the surgical attitude adapted when the functional prognosis is involved [fr

  12. Supratentorial primary intra-axial tumors in children. MR and CT evaluation

    International Nuclear Information System (INIS)

    Higano, S.; Takahashi, S.; Kurihara, N.; Singh, L.N.; Yamada, S.; Ishii, K.; Matsumoto, K.; Shirane, R.; Katakura, R.

    1997-01-01

    Purpose: To evaluate the MR and CT features of pediatric supratentorial intra-axial tumors with respect to different diagnosis and the role of each investigation modality. Material and Methods: MR and CT findings in 40 children with 12 types of pathologically proven histological tumors were reviewed. Results: The location of tumors might be one clue to differential diagnosis. In our material, cysts (60%), calcifications (45%), and intratumoral hemorrhages (27%) were found in the tumors. Characteristic features noted in some lesions included: peritumoral hemosiderin deposition in cavernous angiomas; intratumoral flow void in a choroid plexus carcinoma and in glioblastomas; and hemicerebral atrophy in germinomas. A comparison between malignant and benign tumors showed perifocal edema and a mass effect to be signifcantly more common in malignant lesions. Homogeneous enhancement suggested a benign tumor and an inhomogeneous pattern represented malignancy, while the lack of obvious enhancement did not always suggest benignity. Intratumoral calcium deposition was a not uncommon finding in malignant tumors. Conclusion: In most cases, the exact diagnosis should be made hy histological examination but it is important for treatment planning that the appropriate depiction of tumor extension and tissue characterization be made by MR and CT. (orig.)

  13. MR imaging in tumor invasion of the chest wall

    International Nuclear Information System (INIS)

    Bittner, R.C.; Lang, P.; Schorner, W.; Sander, B.; Weiss, T.; Loddenkemper, R.; Kaiser, D.; Felix, R.

    1989-01-01

    The authors have used MR imaging to study 22 patients who had intrathoracic, pleura-related malignancies and whose CT findings had suggested chest wall invasion. ECG-gated T1- and T2-weighted spin-echo sequences were used in all patients. Additionally, in 10 patients an ungated, multisection, gradient-echo sequence was used, which was repeated after intravenous administration of Gd-DTPA in five patients. Surgery confirmed chest wall invasion in 19 patients. CT showed tumor invasion only in 14 of these 19 patients. MR imaging showed high-signal-intensity lesion within chest wall and pleura in T2-weighted and Gd-DTPA-enhanced T1-weighted images as the typical pattern of chest wall invasion in all 19 patients. Two of the three patients with pleural inflammation and without chest wall invasion had high-signal-intensity pleural lesions, but none of these lesions were within the chest wall

  14. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  15. Imaging of urinary bladder tumors

    International Nuclear Information System (INIS)

    Hadjidekov, G.

    2015-01-01

    Full text: Primary bladder neoplasms account for 2%-6% of all tumors, with urinary bladder cancer ranked as the fourth most common cancer in males. Transitional cell carcinoma (TCC) is the most common subtype of urothelial tumour accounting for approximately 90% of all urothelial cancers. It is typically observed in men aged 50-70 years with history of smoking or occupational exposure to carcinogens. Most urothelial neoplasms are low-grade papillary tumors, with high incidence of recurrence, requires rigorous follow-up but have a relatively good prognosis. Other bladder neoplasm include squamous cell carcinoma accounts for 2%-15% mainly according to geographic location; adenocarcinoma - less than 2% /both occurring in the context of chronic bladder infection and irritation/; mesenchymal tumors in 5%, with the most common examples being rhabdomyosarcoma in children and leiomyosarcoma in adults. More rare mesenchymal tumors include paraganglioma, lymphoma, leiomyoma and solitary fibrous tumor which have no specific typical imaging findings to be differentiated. Multidetector computed tomography urography is an efficient tool for diagnosis and follow-up in patients with transitional cell carcinoma and it can be considered the primary radiologic method for detection, staging and assessment of the entire urothelium regarding the multicentric nature of TCC. MRI is rapidly expanding modality of choice especially in locally staging the tumor and in controversies. Accurate TNM staging is primordial in choosing treatment and prognosis for patients with bladder carcinoma. Correct interpretation and classification of the tumour is helpful for the urologists to determine further management in these cases. The learning objectives of the presentation are: to illustrate the spectrum of CT and MRI findings and to assess their clinical value in patients with transitional cell carcinoma and some other bladder neoplasm; to discuss the TNM staging based on the imaging findings; to be

  16. Spinal tumors

    International Nuclear Information System (INIS)

    Goethem, J.W.M. van; Hauwe, L. van den; Oezsarlak, Oe.; Schepper, A.M.A. de; Parizel, P.M.

    2004-01-01

    Spinal tumors are uncommon lesions but may cause significant morbidity in terms of limb dysfunction. In establishing the differential diagnosis for a spinal lesion, location is the most important feature, but the clinical presentation and the patient's age and gender are also important. Magnetic resonance (MR) imaging plays a central role in the imaging of spinal tumors, easily allowing tumors to be classified as extradural, intradural-extramedullary or intramedullary, which is very useful in tumor characterization. In the evaluation of lesions of the osseous spine both computed tomography (CT) and MR are important. We describe the most common spinal tumors in detail. In general, extradural lesions are the most common with metastasis being the most frequent. Intradural tumors are rare, and the majority is extramedullary, with meningiomas and nerve sheath tumors being the most frequent. Intramedullary tumors are uncommon spinal tumors. Astrocytomas and ependymomas comprise the majority of the intramedullary tumors. The most important tumors are documented with appropriate high quality CT or MR images and the characteristics of these tumors are also summarized in a comprehensive table. Finally we illustrate the use of the new World Health Organization (WHO) classification of neoplasms affecting the central nervous system

  17. CT analysis of intratumoral gas formation after hepatic tumor embolization

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Ahn, In Oak; Kim, Hyung Jin; Lee, Goo; Chung, Sung Hoon

    1994-01-01

    To evaluate the prevalence and the patterns of sterile gas shown at computed tomography(CT) after transarterial embolization(TAE) for primary hepatic tumor. Among 102 patients who performed TAE for hepatoma, thirty-four in whom follow-up CT was underwent constituted the basis of our study. At CT, we evaluated the patterns and locations of intratumoral gas. We also reviewed the clinical data to exclude an infectious origin of intratumoral gas. Of 34 patients, intratumoral gas was detected in 11 patients(32%), in all of whom Gelfoam was used as an embolic material. The initial tumor size measured at pre-TAE CT was larger in patients with intratumoral gas than in patients without it(p < 0.005). No specific patterns or locations of intratumoral gas were noted on CT scans. No patients had clinical signs and symptoms that suggested infection. Intratumoral gas formation without clinical evidence of infection is not an infrequent finding after TAE for hepatoma, especially when Gelfoam is used and when the tumor is larger in size. This finding may be a part of postinfarction syndrome and should not be misinterpreted as an postprocedural abscess formation

  18. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  19. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  20. Response evaluation of giant-cell tumor of bone treated by denosumab: Histogram and texture analysis of CT images.

    Science.gov (United States)

    Yi, Jisook; Lee, Young Han; Kim, Sang Kyum; Kim, Seung Hyun; Song, Ho-Taek; Shin, Kyoo-Ho; Suh, Jin-Suck

    2018-05-01

    This study aimed to compare computed tomography (CT) features, including tumor size and textural and histogram measurements, of giant-cell tumors of bone (GCTBs) before and after denosumab treatment and determine their applicability in monitoring GCTB response to denosumab treatment. This retrospective study included eight patients (male, 3; female, 5; mean age, 33.4 years) diagnosed with GCTB, who had received treatment by denosumab and had undergone pre- and post-treatment non-contrast CT between January 2010 and December 2016. This study was approved by the institutional review board. Pre- and post-treatment size, histogram, and textural parameters of GCTBs were compared by the Wilcoxon signed-rank test. Pathological findings of five patients who underwent surgery after denosumab treatment were evaluated for assessment of treatment response. Relative to the baseline values, the tumor size had decreased, while the mean attenuation, standard deviation, entropy (all, P = 0.017), and skewness (P = 0.036) of the GCTBs had significantly increased post-treatment. Although the difference was statistically insignificant, the tumors also exhibited increased kurtosis, contrast, and inverse difference moment (P = 0.123, 0.327, and 0.575, respectively) post-treatment. Histologic findings revealed new bone formation and complete depletion or decrease in the number of osteoclast-like giant cells. The histogram and textural parameters of GCTBs changed significantly after denosumab treatment. Knowledge of the tendency towards increased mean attenuation and heterogeneity but increased local homogeneity in post-treatment CT histogram and textural features of GCTBs might aid in treatment planning and tumor response evaluation during denosumab treatment. Copyright © 2018. Published by Elsevier B.V.

  1. SU-E-J-91: Biomechanical Deformable Image Registration of Longitudinal Lung CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Cazoulat, G; Owen, D; Matuszak, M; Balter, J; Brock, K [University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Methods: Four lung cancer patients previously treated with conventionally fractionated radiotherapy that exhibited notable tumor shrinkage during treatment were retrospectively evaluated. Exhale breathhold CT scans were obtained at treatment planning (PCT) and following three weeks (W3CT) of treatment. For each patient, the PCT was registered to the W3CT using Morfeus, a biomechanical model-based deformable registration algorithm, consisting of boundary conditions on the lungs and incorporating a sliding interface between the lung and chest wall. To model the complex response of the lung, an extension to Morfeus has been developed: (i) The vessel tree was segmented by thresholding a vesselness image based on the Hessian matrix’s eigenvalues and the centerline was extracted; (ii) A 3D shape context method was used to find correspondences between the trees of the two images; (ii) Correspondences were used as additional boundary conditions (Morfeus+vBC). An expert independently identified corresponding landmarks well distributed in the lung to compute Target Registration Errors (TRE). Results: The TRE within 15mm of the tumor boundaries (on average 11 landmarks) is: 6.1±1.8, 4.6±1.1 and 3.8±2.3 mm after rigid registration, Morfeus and Morfeus+vBC, respectively. The TRE in the rest of the lung (on average 13 landmarks) is: 6.4±3.9, 4.7±2.2 and 3.6±1.9 mm, which is on the order of the 2mm isotropic dose grid vector (3.5mm). Conclusion: The addition of boundary conditions on the vessels improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these

  2. CT features of invasion of sublingual space by malignant oropharyngeal tumors

    International Nuclear Information System (INIS)

    Wei Yi; Xiao Jiahe; Zhou Xiangping; Deng Kaihong

    2003-01-01

    Objective: To investigate the CT features of the invasion of sublingual space by malignant oropharyngeal tumors in order to provide more accurate information for clinical treatment. Methods: Fifty-eight cases of pathologically proven malignant oropharyngeal tumors were collected and retrospectively analyzed. Results: Among all the cases, invasion of sublingual space by malignant oropharyngeal tumors could be seen in 14 cases, of which, 7 cases got access to sublingual space through tongue base, 3 cases through parapharyngeal space, 2 cases through pterygomandibular raphe, 2 cases through uncertain routes. Invasion of sublingual space manifested on CT scan as obliteration of fat plane in sublingual space and involvement of the sublingual vessels in the space. Conclusion: Malignant oropharyngeal tumors can invade the adjacent sublingual space via tongue base, pterygomandibular raphe, and parapharyngeal space. The invasion of sublingual space by malignant oropharyngeal tumors manifests in CT as effacement of sublingual fat plane and envelopment of hyoid artery

  3. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    International Nuclear Information System (INIS)

    Vos, C.G.; Paul, M.A.; Dahele, M.; Soernsen de Koste, J.R. van; Senan, S.; Bahce, I.; Smit, E.F.; Thunnissen, E.; Hartemink, K.J.

    2014-01-01

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R 2 = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  4. The correlation of preoperative CT, MR imaging, and clinical staging (FIGO) with histopathology findings in primary cervical carcinoma

    International Nuclear Information System (INIS)

    Oezsarlak, Oe.; Schepens, E.; Corthouts, B.; Beeck, B.O. de; Parizel, P.M.; De Schepper, A.M.; Tjalma, W.; Marck, E. van

    2003-01-01

    The aim of this study was to compare the preoperative findings of abdominal/pelvic CT and MRI with the preoperative clinical International Federation of Obstetrics and Gynecology (FIGO) staging and postoperative pathology report in patients with primary cancer of the cervix. Thirty-six patients with surgical-pathological proven primary cancer of the cervix were retrospectively studied for preoperative staging by clinical examination, CT, and MR imaging. Studied parameters for preoperative staging were the presence of tumor, tumor extension into the parametrial tissue, pelvic wall, adjacent organs, and lymph nodes. The CT was performed in 32 patients and MRI (T1- and T2-weighted images) in 29 patients. The CT and MR staging were based on the FIGO staging system. Results were compared with histological findings. The group is consisted of stage 0 (in situ):1, Ia:1, Ib:8, IIa:2, IIb:12, IIIa:4, IVa:6, and IVb:2 patients. The overall accuracy of staging for clinical examination, CT, and MRI was 47, 53, and 86%, respectively. The MRI incorrectly staged 2 patients and did not visualize only two tumors; one was an in situ (stage-0) and one stage-Ia (microscopic) disease. The MRI is more accurate than CT and they are both superior to clinical examination in evaluating the locoregional extension and preoperative staging of primary cancer of the cervix. (orig.)

  5. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  6. Can the localization of primary colonic tumors be improved by staging CT without specific bowel preparation compared to optical colonoscopy?

    International Nuclear Information System (INIS)

    Feuerlein, Sebastian; Grimm, Lars J.; Davenport, Matthew S.; Haystead, Clare M.; Miller, Chad M.; Neville, Amy M.; Jaffe, Tracy A.

    2012-01-01

    Objectives: To investigate the ability of staging computed tomography (CT) without bowel preparation to accurately localize colonic tumors compared to optical colonoscopy. Methods: The local institutional review board approved this retrospective and HIPAA-compliant study. Forty-six patients with colonic adenocarcinoma, preoperative colonoscopy, and staging CT within 60 days of resection were included. Patients underwent contrast enhanced CT imaging without bowel preparation or oral contrast. The colon was divided into four segments with the operative reports used as the standard. Rectal and cecal cancers were excluded. CT scans were reviewed by 5 readers in a segmental binary fashion using a 5-point confidence scale in two sessions blinded and unblinded to the colonoscopy report. Results: At surgery 49 tumors were found in 46 patients. Readers detected 86.1%, 74.3%, and 66.9% of lesions with 92.0%, 94.1%, and 95.4% accuracy for confidence scores of ≥3, ≥4, and 5. CT interobserver agreement was good (κ = 0.82) for the unblinded and moderate (κ = 0.60) for the blinded read. Colonoscopic localization was only 78.7% accurate with 2 tumors undiscovered. Colonoscopic accuracy was low in the descending colon (57.1%) and the transverse colon (55.6%). Conclusions: Preoperative staging CT is more accurate than colonoscopy in the localization of colonic tumors

  7. Multi-modality imaging of tumor phenotype and response to therapy

    Science.gov (United States)

    Nyflot, Matthew J.

    2011-12-01

    Imaging and radiation oncology have historically been closely linked. However, the vast majority of techniques used in the clinic involve anatomical imaging. Biological imaging offers the potential for innovation in the areas of cancer diagnosis and staging, radiotherapy target definition, and treatment response assessment. Some relevant imaging techniques are FDG PET (for imaging cellular metabolism), FLT PET (proliferation), CuATSM PET (hypoxia), and contrast-enhanced CT (vasculature and perfusion). Here, a technique for quantitative spatial correlation of tumor phenotype is presented for FDG PET, FLT PET, and CuATSM PET images. Additionally, multimodality imaging of treatment response with FLT PET, CuATSM, and dynamic contrast-enhanced CT is presented, in a trial of patients receiving an antiangiogenic agent (Avastin) combined with cisplatin and radiotherapy. Results are also presented for translational applications in animal models, including quantitative assessment of proliferative response to cetuximab with FLT PET and quantification of vascular volume with a blood-pool contrast agent (Fenestra). These techniques have clear applications to radiobiological research and optimized treatment strategies, and may eventually be used for personalized therapy for patients.

  8. Do Tumors in the Lung Deform During Normal Respiration? An Image Registration Investigation

    International Nuclear Information System (INIS)

    Wu Jianzhou; Lei Peng; Shekhar, Raj; Li Huiling; Suntharalingam, Mohan; D'Souza, Warren D.

    2009-01-01

    Purpose: The purpose of this study was to investigate whether lung tumors may be described adequately using a rigid body assumption or whether they deform during normal respiration. Methods and Materials: Thirty patients with early stage non-small-cell lung cancer underwent four-dimensional (4D) computed tomography (CT) simulation. The gross tumor volume (GTV) was delineated on the 4D CT images. Image registration was performed in the vicinity of the GTV. The volume of interest for registration was the GTV and minimal volume of surrounding non-GTV tissue. Three types of registration were performed: translation only, translation + rotation, and deformable. The GTV contour from end-inhale was mapped to end-exhale using the registration-derived transformation field. The results were evaluated using three metrics: overlap index (OI), root-mean-squared distance (RMS), and Hausdorff distance (HD). Results: After translation only image registration, on average OI increased by 21.3%, RMS and HD reduced by 1.2 mm and 2.0 mm, respectively. The succeeding increases in OI after translation + rotation and deformable registration were 1.1% and 1.4% respectively. The succeeding reductions in RMS were 0.1 mm and 0.2 mm respectively. No reduction in HD was observed after translation + rotation and deformable image registration compared with translation only registration. The difference in the results from the three registration scenarios was independent of GTV size and motion amplitude. Conclusions: The primary effect of normal respiration on lung tumors was the translation of tumors. Rotation and deformation of lung tumors was determined to be minimal.

  9. Brown Tumors Due to Primary Hyperparathyroidism in a Patient with Parathyroid Carcinoma Mimicking Skeletal Metastases on (18)F-FDG PET/CT

    DEFF Research Database (Denmark)

    Andersen, Kim Francis; Albrecht-Beste, Elisabeth

    2015-01-01

    -so-called brown tumors. These benign, osteolytic lesions may demonstrate FDG-avidity on (18)F-FDG PET/CT, and as such are misinterpreted as skeletal metastases. Regression of the lesions may occur following successful treatment. We present a case demonstrating the diagnostic work-up and follow-up of a patient...... with PHPT due to parathyroid carcinoma and with presence of brown tumors on (18)F-FDG PET/CT, visualizing the possible role of this imaging modality in the evaluation of treatment response in these patients....

  10. Delineation and segmentation of cerebral tumors by mapping blood-brain barrier disruption with dynamic contrast-enhanced CT and tracer kinetics modeling-a feasibility study

    International Nuclear Information System (INIS)

    Bisdas, S.; Vogl, T.J.; Yang, X.; Koh, T.S.; Lim, C.C.T.

    2008-01-01

    Dynamic contrast-enhanced (DCE) imaging is a promising approach for in vivo assessment of tissue microcirculation. Twenty patients with clinical and routine computed tomography (CT) evidence of intracerebral neoplasm were examined with DCE-CT imaging. Using a distributed-parameter model for tracer kinetics modeling of DCE-CT data, voxel-level maps of cerebral blood flow (F), intravascular blood volume (v i ) and intravascular mean transit time (t 1 ) were generated. Permeability-surface area product (PS), extravascular extracellular blood volume (v e ) and extraction ratio (E) maps were also calculated to reveal pathologic locations of tracer extravasation, which are indicative of disruptions in the blood-brain barrier (BBB). All maps were visually assessed for quality of tumor delineation and measurement of tumor extent by two radiologists. Kappa (κ) coefficients and their 95% confidence intervals (CI) were calculated to determine the interobserver agreement for each DCE-CT map. There was a substantial agreement for the tumor delineation quality in the F, v e and t 1 maps. The agreement for the quality of the tumor delineation was excellent for the v i , PS and E maps. Concerning the measurement of tumor extent, excellent and nearly excellent agreement was achieved only for E and PS maps, respectively. According to these results, we performed a segmentation of the cerebral tumors on the base of the E maps. The interobserver agreement for the tumor extent quantification based on manual segmentation of tumor in the E maps vs. the computer-assisted segmentation was excellent (κ = 0.96, CI: 0.93-0.99). The interobserver agreement for the tumor extent quantification based on computer segmentation in the mean images and the E maps was substantial (κ = 0.52, CI: 0.42-0.59). This study illustrates the diagnostic usefulness of parametric maps associated with BBB disruption on a physiology-based approach and highlights the feasibility for automatic segmentation of

  11. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  12. Clinical significance of 18F-fluorodeoxyglucose PET/CT whole body imaging in detecting thyroid incidentaloma

    International Nuclear Information System (INIS)

    Zhai Ge; Li Biao; Zhang Miao; Xu Haoping; Jiang Xufeng; Wang Chao; Ge Guizhi; Shun Chengwei; Zhu Chengmo

    2009-01-01

    Objective: 18 F-fluorodeoxyglucose (FDG) PET/CT is a noninvasive whole-body imaging technique used to evaluate various types of malignancies. Recent advances have rapidly developed it into a diagnostic imaging modality in ontology. The aims of this study were two. One was to estimate the detection rate of thyroid indoleacetamide and the risk of thyroid malignancy by 18 F-FDG PET/CT scan and the other Was to further understand whether the maximum standardized uptake value (SUV max ) would be helpful in differentiating benign from malignant thyroid tumor. Methods: From June 2007 to January 2008, a total of 1190 subjects who had no previous history of thyroid cancer and had 18 F-FDG PET/CT scan were included. All had visual interpretation and semiquantitative analyses by SUV max at thyroid incidentalomas detected by FDG PET/CT. Kruskal-Wallis test and Spearman relation analysis were used. Results: The prevalence of thyroid incidentaloma on 18 F-FDG PET/CT wag 2.1% (25/1190). Of these 25 tumors, 20 had histologically proven. Of these 20 tumors, 9 were benign and 11 were malignant (papillary carcinoma of thyroid gland in 9, follicular carcinoma of thyroid gland in 1, metastatic squamous cell carcinoma from lung cancer in 1). Therefore,the cancer risk of thyroid incidentaloma was 55% (11/20). Significantly higher SUV max in malignant than in benign nodules were observed (Kruskal-Wallis test,χ 2 =8.8, P max (3.0-46.0) and maximal diameter (1.0-4.2 cm) of nodule findings was insignificant (r=0.25, P>0.01). Conclusion: Thyroid incidentaloma detected by 18 F-FDG PET/CT has higher risk rate for thyroid malignancy.(authors)

  13. The role of three-dimensional multidetector CT gastrography in the preoperative imaging of stomach cancer: Emphasis on detection and localization of the tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Park, Young Kyu; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of); Lim, Nam Yeol [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2015-02-15

    Multidetector CT (MDCT) gastrography has been regarded as a promising technique for the preoperative imaging of gastric cancer. It has the ability to produce various three-dimensional (3D) images. Because 3D reconstruction images are more effective and intuitive for recognizing abnormal changes in the gastric folds and subtle mucosal nodularity than two-dimensional images, 3D MDCT gastrography can enhance the detection rate of early gastric cancer, which, in turn, contributes to the improvement of the accuracy of preoperative tumor (T) staging. In addition, shaded surface display and tissue transition projection images provide a global view of the stomach, with the exact location of gastric cancer, which may replace the need for barium studies. In this article, we discuss technical factors in producing high-quality MDCT gastrographic images and present cases demonstrating the usefulness of MDCT gastrography for the detection and T staging of gastric cancer while emphasizing the significance of preoperative localization of gastric cancer in terms of surgical margin.

  14. Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue

    Science.gov (United States)

    McClatchy, David M., III; Rizzo, Elizabeth J.; Meganck, Jeff; Kempner, Josh; Vicory, Jared; Wells, Wendy A.; Paulsen, Keith D.; Pogue, Brian W.

    2017-12-01

    A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast of 1.64, and a minimum detectable resolution of 240 μm for a 1.2 min scan. The SLI system, spanning wavelengths 490 nm to 800 nm and spatial frequencies up to 1.37 mm-1 , was evaluated with aqueous tissue simulating phantoms having variations in particle size distribution, scatter density, and blood volume fraction. The reduced scattering coefficient, μs\\prime and phase function parameter, γ, were accurately recovered over all wavelengths independent of blood volume fractions from 0% to 4%, assuming a flat sample geometry perpendicular to the imaging plane. The resolution of the optical system was tested with a step phantom, from which the modulation transfer function was calculated yielding a maximum resolution of 3.78 cycles per mm. The three dimensional spatial co-registration between the CT and optical imaging space was tested and shown to be accurate within 0.7 mm. A freshly resected breast specimen, with lobular carcinoma, fibrocystic disease, and adipose, was imaged with the system. The micro-CT provided visualization of the tumor mass and its spiculations, and SLI yielded superficial quantification of light scattering parameters for the malignant and benign tissue types. These results appear to be the first demonstration of SLI combined with standard medical tomography for imaging excised tumor specimens. While further investigations are needed to determine and test the spectral, spatial, and CT features required to classify tissue, this study demonstrates the ability of multimodal CT/SLI to quantify, visualize, and spatially navigate breast tumor specimens, which could potentially aid in the assessment of tumor margin status during

  15. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  16. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  17. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  18. An unusual mature thyroid teratoma on CT and {sup 99}Tcm scintigraphy imaging in a child

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu-Zhen; Li, Wen-Hua; Li, Yu-Hua; Gao, Yu [Xin Hua Hospital, Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai (China); Zhu, Ming-Jie [Xin Hua Hospital, Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai (China); Xin Hua Hospital, Shanghai Jiaotong University School of Medicine, Department of Pathology, Shanghai (China)

    2010-11-15

    We report the imaging findings of a mature thyroid teratoma in a 5-year-old girl. Nuclear imaging showed a decrease in {sup 99}Tcm uptake in the right lobe of the thyroid gland. CT scan showed a slightly lobulated soft-tissue mass without calcification, fat or cystic components. Histological analysis showed that the tumor was composed of mature neural tissue, cartilaginous, and epithelial elements. This case study provides new insights into the CT appearance of mature thyroid teratomas. (orig.)

  19. 18F-FDOPA PET/CT imaging of insulinoma revisited

    International Nuclear Information System (INIS)

    Imperiale, Alessio; Namer, Izzie-Jacques; Sebag, Frederic; Vix, Michel; Castinetti, Frederic; Kessler, Laurence; Moreau, Francois; Bachellier, Philippe; Guillet, Benjamin; Mundler, Olivier; Taieb, David

    2015-01-01

    18 F-FDOPA PET imaging is increasingly used in the work-up of patients with neuroendocrine tumours. It has been shown to be of limited value in localizing pancreatic insulin-secreting tumours in adults with hyperinsulinaemic hypoglycaemia (HH) mainly due to 18 F-FDOPA uptake by the whole pancreatic gland. The objective of this study was to review our experience with 18 F-FDOPA PET/CT imaging with carbidopa (CD) premedication in patients with HH in comparison with PET/CT studies performed without CD premedication in an independent population. A retrospective study including 16 HH patients who were investigated between January 2011 and December 2013 using 18 F-FDOPA PET/CT (17 examinations) in two academic endocrine tumour centres was conducted. All PET/CT examinations were performed under CD premedication (200 mg orally, 1 - 2 h prior to tracer injection). The PET/CT acquisition protocol included an early acquisition (5 min after 18 F-FDOPA injection) centred over the upper abdomen and a delayed whole-body acquisition starting 20 - 30 min later. An independent series of eight consecutive patients with HH and investigated before 2011 were considered for comparison. All patients had a reference whole-body PET/CT scan performed about 1 h after 18 F-FDOPA injection. In all cases, PET/CT was performed without CD premedication. In the study group, 18 F-FDOPA PET/CT with CD premedication was positive in 8 out of 11 patients with histologically proven insulinoma (73 %). All 18 F-FDOPA PET/CT-avid insulinomas were detected on early images and 5 of 11 (45 %) on delayed ones. The tumour/normal pancreas uptake ratio was not significantly different between early and delayed acquisitions. Considering all patients with HH, including those without imaging evidence of disease, the detection rate of the primary lesions using CD-assisted 18 F-FDOPA PET/CT was 53 %, showing 9 insulinomas in 17 studies performed. In the control group (without CD premedication, eight patients), the final

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  1. Differentiation of primary chordoma, giant cell tumor and schwannoma of the sacrum by CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Si, Ming-Jue, E-mail: smjsh@hotmail.com [Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China); Wang, Cheng-Sheng [Department of Radiology, Union Hospital, Fujian Medical University, Fuzhou 350001 (China); Ding, Xiao-Yi, E-mail: dingxiaoyi1965@hotmail.com [Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China); Yuan, Fei, E-mail: yuanfeirj@hotmail.com [Department of Pathology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China); Du, Lian-Jun; Lu, Yong [Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China); Zhang, Wei-Bin [Department of Orthopedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China)

    2013-12-01

    Objective: To evaluate criteria to differentiate sacral chordoma (SC), sacral giant cell tumor (SGCT) and giant sacral schwannoma (GSS) with CT and MRI. Materials and methods: CT and MR images of 22 SCs, 19 SGCTs and 8 GSSs were reviewed. The clinical and imaging features of each tumor were analyzed. Results: The mean ages of SC, SGCT and GSS were 55.1 ± 10.7, 34.3 ± 10.7 and 42.4 ± 15.7 years old. SCs (77.3%) were predominantly located in the midline of lower sacrum, while most SGCTs (73.7%) and GSSs (87.5%) were eccentrically located in upper sacrum. There were significant differences in age, location, eccentricity, morphology of bone residues, intratumoral bleeding and septations. Multiple small cysts were mainly observed in SGCTs (73.7%) with large central cysts in GSSs (87.5%). SGCTs expanded mainly inside sacrum while SCs and GSSs often extended into pelvic cavity (P = 0.0022). Involvement of sacroiliac joints and muscles were also different. Ascending extension within sacral canal was only displayed in SCs. The preservation of intervertebral discs showed difference between large and small tumors (P = 0.0002), regardless of tumor type (P = 0.095). No significant difference was displayed in gender (P = 0.234) or tumor size (P = 0.0832) among three groups. Conclusion: Age, epicenter of the lesion (midline vs. eccentric and upper vs. lower sacral vertebra), bone residues, cysts, bleeding, septation, expanding pattern, muscles and sacroiliac joint involvement can be criteria for diagnosis. Fluid–fluid level is specific for SGCTs and ascending extension within the sacral canal for SCs. The preservation of intervertebral discs is related to tumor size rather than tumor type.

  2. Development of 68Ga-Glycopeptide as an Imaging Probe for Tumor Angiogenesis

    Directory of Open Access Journals (Sweden)

    Ning Tsao

    2011-01-01

    Full Text Available Objective. This study was aimed to study tissue distribution and tumor imaging potential of 68Ga-glycopeptide (GP in tumor-bearing rodents by PET. Methods. GP was synthesized by conjugating glutamate peptide and chitosan. GP was labeled with 68Ga chloride for in vitro and in vivo studies. Computer outlined region of interest (counts per pixel of the tumor and muscle (at the symmetric site was used to determine tumor-to-muscle count density ratios. To ascertain the feasibility of 68Ga-GP in tumor imaging in large animals, PET/CT imaging of 68Ga-GP and 18F-FDG were conducted in New Zealand white rabbits bearing VX2 tumors. Standard uptake value of tumors were determined by PET up to 45 min. To determine blood clearance and half-life of 68Ga-GP, blood samples were collected from 10 seconds to 20 min. Results. Radiochemical purity of 68Ga-GP determined by instant thin-layer chromatography was >95%. Tumor uptake values (SUV for 68Ga-GP and 18F-FDG in New Zealand white rabbits bearing VX2 tumors were 3.25 versus 7.04. PET images in tumor-bearing rats and rabbits confirmed that 68Ga-GP could assess tumor uptake. From blood clearance curve, the half-life of 68Ga-GP was 1.84 hr. Conclusion Our data indicate that it is feasible to use 68Ga-GP to assess tumor angiogenesis.

  3. Educational effect of a lecture on differential imaging features comparing ameloblastomas and keratocystic odontogenic tumors of the mandible presented to dental students

    International Nuclear Information System (INIS)

    Morita, Mitsuko; Ariji, Yoshiko; Kise, Yoshitaka; Goto, Masakazu; Izumi, Masahiro; Naitoh, Munetaka; Ariji, Eiichiro; Katsumata, Akitoshi

    2011-01-01

    The objective of this study was to clarify the educational effect of a lecture on differential imaging features comparing ameloblastomas and keratocystic odontogenic tumors of the mandibles presented to dental students. Panoramic and CT images of 10 ameloblastomas and 10 keratocystic odontogenic tumors were randomly presented 114 dental students. Test scores, correct answer ratios, identification index, and understanding of the imaging features contributing to a correct diagnosis were serially evaluated before and after the lecture on the differential imaging features comparing the two types of tumors. The mean and standard deviation of the scoring ratios of dental students diagnosing these lesions on panoramic and CT images were 48.8±10.8% and 52.5±12.9%, respectively. After the lecture on the differential imaging features comparing the two tumors, the scoring ratios improved significantly. After the lecture, both the numbers of patients whose images were correctly diagnosed and the identification indices increased. The lecture also increased the number of imaging features recognized as contributing to the correct diagnosis. A lecture on the differential imaging features comparing ameloblastomas and keratocystic odontogenic tumors of the mandibles contributed to the improvement of imaging diagnosis skills among dental students. (author)

  4. Multimodal imaging in neurofibromatosis type 1-associated nerve sheath tumors; Multimodale Bildgebung bei Neurofibromatose-Typ-1-assoziierten Nervenscheidentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, J.; Adam, G. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Mautner, V.F. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Neurology; Derlin, T. [Hannover Medical School, Hannover (Germany). Dept. of Nuclear Medicine

    2015-12-15

    Neurofibromatosis type 1 (NF1) is a neurogenetic disorder. Individuals with NF1 may develop a variety of benign and malignant tumors of which peripheral nerve sheath tumors represent the most frequent entity. Plexiform neurofibromas may demonstrate a locally destructive growth pattern, may cause severe symptoms and may undergo malignant transformation into malignant peripheral nerve sheath tumors (MPNSTs). Whole-body magnetic resonance imaging (MRI) represents the reference standard for detection of soft tissue tumors in NF1. It allows for identification of individuals with plexiform neurofibromas, for assessment of local tumor extent, and for evaluation of whole-body tumor burden on T2-weighted imaging. Multiparametric MRI may provide a comprehensive characterization of different tissue properties of peripheral nerve sheath tumors, and may identify parameters associated with malignant transformation. Due to the absence of any radiation exposure, whole-body MRI may be used for serial follow-up of individuals with plexiform neurofibromas. {sup 18}F-fluorodeoxyglucose positron-emission-tomography (FDG PET/CT) allows a highly sensitive and specific detection of MPNST, and should be used in case of potential malignant transformation of a peripheral nerve sheath tumor. PET/CT provides a sensitive whole-body tumor staging. The use of contrast-enhanced CT for diagnosis of peripheral nerve sheath tumors is limited to special indications. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of peripheral nerve sheath tumors are required.

  5. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  6. TU-G-BRA-04: Changes in Regional Lung Function Measured by 4D-CT Ventilation Imaging for Thoracic Radiotherapy

    International Nuclear Information System (INIS)

    Nakajima, Y; Kadoya, N; Kabus, S; Loo, B; Keall, P; Yamamoto, T

    2015-01-01

    Purpose: To test the hypothesis: 4D-CT ventilation imaging can show the known effects of radiotherapy on lung function: (1) radiation-induced ventilation reductions, and (2) ventilation increases caused by tumor regression. Methods: Repeat 4D-CT scans (pre-, mid- and/or post-treatment) were acquired prospectively for 11 thoracic cancer patients in an IRB-approved clinical trial. A ventilation image for each time point was created using deformable image registration and the Hounsfield unit (HU)-based or Jacobian-based metric. The 11 patients were divided into two subgroups based on tumor volume reduction using a threshold of 5 cm 3 . To quantify radiation-induced ventilation reduction, six patients who showed a small tumor volume reduction (<5 cm 3 ) were analyzed for dose-response relationships. To investigate ventilation increase caused by tumor regression, two of the other five patients were analyzed to compare ventilation changes in the lung lobes affected and unaffected by the tumor. The remaining three patients were excluded because there were no unaffected lobes. Results: Dose-dependent reductions of HU-based ventilation were observed in a majority of the patient-specific dose-response curves and in the population-based dose-response curve, whereas no clear relationship was seen for Jacobian-based ventilation. The post-treatment population-based dose-response curve of HU-based ventilation demonstrated the average ventilation reductions of 20.9±7.0% at 35–40 Gy (equivalent dose in 2-Gy fractions, EQD2), and 40.6±22.9% at 75–80 Gy EQD2. Remarkable ventilation increases in the affected lobes were observed for the two patients who showed an average tumor volume reduction of 37.1 cm 3 and re-opening airways. The mid-treatment increase in HU-based ventilation of patient 3 was 100.4% in the affected lobes, which was considerably greater than 7.8% in the unaffected lobes. Conclusion: This study has demonstrated that 4D-CT ventilation imaging shows the known

  7. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  8. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  9. Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Hara, Ryusuke; Yanagi, Takeshi; Sharp, Gregory C.; Kumagai, Motoki; Asakura, Hiroshi; Kishimoto, Riwa; Yamada, Shigeru; Kandatsu, Susumu; Kamada, Tadashi

    2009-01-01

    Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors.

  10. CT findings in the leptomeningeal dissemination of tumors

    International Nuclear Information System (INIS)

    Yamazaki, Shingo; Ito, Umeo; Tomita, Hiroki; Takada, Yoshiaki; Ohno, Kikuo; Momma, Seiji; Inaba, Yutaka.

    1986-01-01

    The communicating hydrocephalus, the enhancement of the basal and quadrigeminal cisterns, and the enhancement of the Sylvian fissure, the cortical sulci and the ventricular wall are CT findings reported with regard to the leptomeningeal dissemination of tumors (LMDT). However, these findings are not always observed in patients with LMDT. In the present study, CT findings on 4 patients with LMDT (one from spinal ependymoblastoma, two from gastric cancer; and one from pulmonary cancer) are reported. Depending on the stage of the disease, the appearances of the above LMDT are quite varied. In Case 1, only hydrocephalus was found on admission CT. About one month later, the enhancement of the basal cisterns, the Sylvian fissure, the cerebral sulci, and the ventricular wall was observed, and this enhancement was further intensified later on. In Case 2, the cortical sulci were enhanced without any enhancement of the hydrocephalus or anything else. In Case 3, only the cerebral margin of the posterior lobectomy was enhanced. In Case 4, only a communicating hydrocephalus was observed. However, in all four cases the CSF cytology was positive for tumor cells. The frequency of each CT finding is discussed for the reported 25 cases. (author)

  11. Portable Intraoperative Computed Tomography Scan in Image-Guided Surgery for Brain High-grade Gliomas: Analysis of Technical Feasibility and Impact on Extent of Tumor Resection.

    Science.gov (United States)

    Barbagallo, Giuseppe M V; Palmucci, Stefano; Visocchi, Massimiliano; Paratore, Sabrina; Attinà, Giancarlo; Sortino, Giuseppe; Albanese, Vincenzo; Certo, Francesco

    2016-03-01

    Intraoperative magnetic resonance imaging is the gold standard among image-guided techniques for glioma surgery. Scant data are available on the role of intraoperative computed tomography (i-CT) in high-grade glioma (HGG) surgery. To verify the technical feasibility and usefulness of portable i-CT in image-guided surgical resection of HGGs. This is a retrospective series control analysis of prospectively collected data. Twenty-five patients (Group A) with HGGs underwent surgery using i-CT and 5-aminolevulinic acid (5-ALA) fluorescence. A second cohort of 25 patients (Group B) underwent 5-ALA fluorescence-guided surgery but without i-CT. We used a portable 8-slice CT scanner and, in both groups, neuronavigation. Extent of tumor resection (ETOR) and pre- and postoperative Karnofsky performance status (KPS) scores were measured; the impact of i-CT on overall survival (OS) and progression-free survival (PFS) was also analyzed. In 8 patients (32%) in Group A, i-CT revealed residual tumor, and in 4 of them it helped to also resect pathological tissue detached from the main tumor. EOTR in these 8 patients was 97.3% (96%-98.6%). In Group B, residual tumor was found in 6 patients, whose tumor's mean resection was 98% (93.5-99.7). The Student t test did not show statistically significant differences in EOTR in the 2 groups. The KPS score decreased from 67 to 69 after surgery in Group A and from 74 to 77 in Group B (P = .07 according to the Student t test). Groups A and B did not show statistically significant differences in OS and PFS (P = .61 and .46, respectively, by the log-rank test). No statistically significant differences in EOTR, KPS, PFS, and OS were observed in the 2 groups. However, i-CT helped to verify EOTR and to update the neuronavigator with real-time images, as well as to identify and resect pathological tissue in multifocal tumors. i-CT is a feasible and effective alternative to intraoperative magnetic resonance imaging. Portable i-CT can provide useful

  12. Microcomputer-based image processing system for CT/MRI scans II

    International Nuclear Information System (INIS)

    Kwok, J.C.K.; Yu, P.K.N.; Cheng, A.Y.S.; Ho, W.C.

    1991-01-01

    This paper reports that a microcomputer-based image processing system is used to digitize and process serial sections of CT/MRI scan and reconstruct three-dimensional images of brain structures and brain lesions. The images grabbed also serve as templates and different vital regions with different risk values are also traced out for 3D reconstruction. A knowledge-based system employing rule-based programming has been built to help identifying brain lesions and to help planning trajectory for operations. The volumes of the lesions are also automatically determined. Such system is very useful for medical skills archival, tumor size monitoring, survival and outcome forecasting, and consistent neurosurgical planning

  13. Clinical PET/CT imaging. Promises and misconceptions

    International Nuclear Information System (INIS)

    Czernin, J.; Auerbach, M.A.

    2005-01-01

    PET/CT is now established as the most important imaging tool in oncology. PET/CT stages and restages cancer with a higher accuracy than PET or CT alone. The sometimes irrational approach to combine state of the art PET with the highest end CT devices should give way to a more reasonable equipment design tailored towards the specific clinical indications in well-defined patient populations. The continuing success of molecular PET/CT now depends more upon advances in molecular imaging with the introduction of targeted imaging probes for individualized therapy approaches in cancer patients and less upon technological advances of imaging equipment. (orig.)

  14. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  15. FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

    International Nuclear Information System (INIS)

    Bassi, Maria Chiara; Turri, Lucia; Sacchetti, Gianmauro; Loi, Gianfranco; Cannillo, Barbara; La Mattina, Pierdaniele; Brambilla, Marco; Inglese, Eugenio; Krengli, Marco

    2008-01-01

    Purpose: To investigate the potential impact of using 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively

  16. Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

    Science.gov (United States)

    Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong

    2015-07-08

    Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons

  17. Improved longitudinal length accuracy of gross tumor volume delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Hou, Dong-Liang; Shi, Gao-Feng; Gao, Xian-Shu; Asaumi, Junichi; Li, Xue-Ying; Liu, Hui; Yao, Chen; Chang, Joe Y

    2013-01-01

    To analyze the longitudinal length accuracy of gross tumor volume (GTV) delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma (SCC). Forty-two patients from December 2011 to June 2012 with esophageal SCC who underwent radical surgery were analyzed. Routine computed tomography (CT) scan, T2-weighted MRI and diffusion weighted magnetic resonance imaging (DWI) were employed before surgery. Diffusion-sensitive gradient b-values were taken at 400, 600, and 800 s/mm 2 . Gross tumor volumes (GTV) were delineated using CT, T2-weighted MRI and DWI on different b-value images. GTV longitude length measured using the imaging modalities listed above was compared with pathologic lesion length to determine the most accurate imaging modality. CMS Xio radiotherapy planning system was used to fuse DWI scans and CT images to investigate the possibility of delineating GTV on fused images. The differences between the GTV length according to CT, T2-weighted MRI and pathology were 3.63 ± 12.06 mm and 3.46 ± 11.41 mm, respectively. When the diffusion-sensitive gradient b-value was 400, 600, and 800 s/mm 2 , the differences between the GTV length using DWI and pathology were 0.73 ± 6.09 mm, -0.54 ± 6.03 mm and −1.58 ± 5.71 mm, respectively. DWI scans and CT images were fused accurately using the radiotherapy planning system. GTV margins were depicted clearly on fused images. DWI displays esophageal SCC lengths most precisely when compared with CT or regular MRI. DWI scans fused with CT images can be used to improve accuracy to delineate GTV in esophageal SCC

  18. Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Yong; Lim, Sang Wook; Ma, Sun Young; Yu, Je Sang [Dept. of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of)

    2017-09-15

    To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%–60%, 30%–70%, and 0%–90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. As narrow as possible duty cycle such as 40%–60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

  19. The role of 68Ga-DOTA-NOC PET/CT in evaluating neuroendocrine tumors: real-world experience from two large neuroendocrine tumor centers.

    Science.gov (United States)

    Haidar, Mohamad; Shamseddine, Ali; Panagiotidis, Emmanouil; Jreige, Mario; Mukherji, Deborah; Assi, Rita; Abousaid, Rayan; Ibrahim, Toni; Haddad, Marwan M; Vinjamuri, Sobhan

    2017-02-01

    Our aim was to assess the role of Ga-DOTA-NOC PET/CT as a tool for the management of neuroendocrine tumors (NETs), evaluating the clinical impact on patients from two large NET centers in different geopolitical settings. This is a retrospective study of patients with NETs who underwent Ga-DOTA-NOC PET/CT at Royal Liverpool University Hospital (UK) and at Mount Lebanon Hospital (Lebanon). Indications for imaging and findings of the PET/CT along with demographic and clinical outcome data were recorded and evaluated. Four hundred and forty-five patients fulfilled the inclusion criteria, with a median age at the time of diagnosis of 56 (range: 3-90) years; 248 (55.7%) patients were male.Ga-DOTA-NOC PET/CT was indicated for staging in 193 (43.4%) patients, for diagnosis in 124 (27.9%) patients, for follow-up in 97 (21.7%) patients, and for identification of a primary NET site in 31 (7%) patients.One hundred and four (27.9%) patients underwent Ga-DOTA-NOC PET/CT for the primary diagnosis of NET, of whom 66 (52.7%) patients presented with a clinical suspicion of NET, 10 (8.3%) patients presented with a biochemical suspicion of NET only, and 48 (38.8%) patients presented with a suspicious NET lesion discovered on another imaging modality. The most common clinical presentation was typical carcinoid syndrome [4 (33%) patients].Results on the basis of histology were used as the gold standard for the diagnosis in 57% of patients and the remaining on the basis of follow-up as per established clinical consensus. Sensitivity, specificity, negative-predictive value, and positive-predictive value of PET/CT were 87.1, 97.7, 79.6, and 98.7%, respectively, for the entire sample. Accuracy was measured using the receiver operating characteristic curve analysis with an area under the curve of 0.924 (95% confidence interval: 0.874-0.974). Ga-DOTA-NOC PET/CT is a highly sensitive and specific study for the diagnosis and follow-up of patients with neuroendocrine tumors. These results

  20. Three-dimensional reconstruction of CT images

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Toshiaki; Kattoh, Keiichi; Kawakami, Genichiroh; Igami, Isao; Mariya, Yasushi; Nakamura, Yasuhiko; Saitoh, Yohko; Tamura, Koreroku; Shinozaki, Tatsuyo

    1986-09-01

    Computed tomography (CT) has the ability to provide sensitive visualization of organs and lesions. Owing to the nature of CT to be transaxial images, a structure which is greater than a certain size appears as several serial CT images. Consequently each observer must reconstruct those images into a three-dimensional (3-D) form mentally. It has been supposed to be of great use if such a 3-D form can be described as a definite figure. A new computer program has been developed which can produce 3-D figures from the profiles of organs and lesions on CT images using spline curves. The figures obtained through this method are regarded to have practical applications.

  1. Evaluation of 68Ga-DOTA-TOC PET/CT for the detection of duodenopancreatic neuroendocrine tumors in patients with MEN1

    International Nuclear Information System (INIS)

    Morgat, Clement; Mazere, Joachim; Hindie, Elif; Fernandez, Philippe; Velayoudom-Cephise, Fritz-Line; Nunes, Marie-Laure; Tabarin, Antoine; Schwartz, Paul; Guyot, Martine; Gaye, Delphine; Vimont, Delphine; Schulz, Juergen; Smith, Denis

    2016-01-01

    Somatostatin receptor scintigraphy with 111 In-pentetreotide (SRS) is used to detect duodenopancreatic neuroendocrine tumors (dpNETs) in multiple endocrine neoplasia type 1 (MEN1). However, SRS has limited sensitivity for this purpose. Positron emission tomography/computed tomography (PET/CT) with 68 Ga-DOTA-TOC has a higher rate of sporadic dpNETs detection than SRS but there is little data for dpNETs detection in MEN1. To compare the performances of 68 Ga-DOTA-TOC PET/CT, SRS and contrast-enhanced computed tomography (CE-CT) to diagnose dpNETs in MEN1. Single-institution prospective comparative study Nineteen consecutive MEN1 patients (aged 47 ± 13 years) underwent 68 Ga-DOTA-TOC PET/CT, SRS, and CE-CT within 2 months in random order. Blinded readings of images were performed separately by experienced physicians. Unblinded analysis of CE-CT, combined with additional magnetic resonance imaging, endoscopic-ultrasound, 18 F-2-fluoro-deoxy-d-glucose ( 18 F-FDG) PET/CT or histopathology results served as reference standard for dpNETs diagnosis. The sensitivity of 68 Ga-DOTA-TOC PET/CT, SRS, and CE-CT was 76, 20, and 60 %, respectively (p < 0.0001). All the true-positive lesions detected by SRS were also depicted on 68 Ga-DOTA-TOC PET/CT. 68 Ga-DOTA-TOC PET/CT detected lesions of smaller size than SRS (10.7 ± 7.6 and 15.2 ± 5.9 mm, respectively, p < 0.03). False negatives of 68 Ga-DOTA-TOC PET/CT included small dpNETs (<10 mm) and 18 F-FDG PET/CT positive aggressive dpNETs. No false positives were recorded. In addition, whole-body mapping with 68 Ga-DOTA-TOC PET/CT identified extra-abdominal MEN1-related tumors including one neuroendocrine thymic carcinoma identified by the three imaging procedures, one bronchial carcinoid undetected by CE-CT and three meningiomas undetected by SRS. Owing to higher diagnostic performance, 68 Ga-DOTA-TOC PET/CT (or alternative 68 Ga-labeled somatostatin analogues) should replace 111 In-pentetreotide in the investigation of MEN1

  2. Malignant phyllodes tumor of the breast metastasizing to the vulva: {sup 18}F FDG PET CT Demonstrating rare metastasis from a rare tumor

    Energy Technology Data Exchange (ETDEWEB)

    Khangembam, Bang Kim Chand Ra; Sharma, Punit; Singla, Su Has; Singhal, Abinav; Dhull, Varun Singh; Bal, Chand Rasek Har; Kumar, Rakesh [All India Institute of Medical Sciences, New Delhi (India)

    2012-09-15

    Phyllodes tumors are extremely rare fibroepithelial neoplasms accounting for 0.3 to 0.5% of all female breast tumors with an incidence of 2.1 per 1 million women. They are classified histologically into benign, borderline and malignant varieties. The majority of them are benign, with only 25% being malignant. Surgery remains the mainstay of treatment. One characteristic is that although the malignant variety tends to metastasize and recur, the benign form has also been found to behave in a similar manner. Benign phyllodes tumor has a 21% risk of local recurrence, while that of the malignant variety ranges from 20 to 32%. In patients with malignant phyllodes tumor, the rate of distant metastases ranges from 25 to 40%. The most frequent sites of distant metastasis is uncommon as this tumor spreads by hematogeneous route. Other sites for distant metastasis have been reported sporadically, including the duodenum, pancreas, brain, nasal cavity, forearm, parotid, skin, oral cavity, skeletal muscle, mandible and maxilla. We present a rare case of recurrent malignant phyllodes tumor with metastasis to the vulva, which has not been reported in the literature to the best of our knowledge. A 49 year old female who had undergone lumpectomy and locoregional radiotherapy 1 year previously for malignant phyllodes tumor of the right breast presented with difficulty in breathing and cervical lymphadenopathy. Chest X ray showed multiple pulmonary nodules suggestive of metastasis. She was referred for restaging with 18F fluorodeoxyglucose (FDG)positron emission tomography computed tomography (PET CT)FDG PET CT. Maximum intensity projection (MIP)PET images revealed multiple FDG avid enlarged cervical lymph nodes, bilateral pulmonary nodules along with left pleural effusion and extensive bone marrow metastases. The interesting finding was an intensely FDG avid (SUV{sup max}-21.4)subcutaneous soft tissue density lesion (measuring 2.0x2.2x2.0cm)in the vulva, which was later proved to be

  3. Giant cell tumor of soft tissue: a case report with emphasis on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Moon Young; Jee, Won-Hee [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Seocho-gu, Seoul (Korea, Republic of); Jung, Chan Kwon [The Catholic University of Korea, Department of Pathology, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Yoo, Ie Ryung [The Catholic University of Korea, Department of Nuclear Medicine, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Chung, Yang-Guk [The Catholic University of Korea, Department of Orthopedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of)

    2015-04-03

    Giant cell tumor of soft tissue is a rare neoplasm, histologically resembling giant cell tumor of bone. In this report, we describe a deep and solid giant cell tumor of soft tissue interpreted as a benign soft tissue tumor based on magnetic resonance (MR) findings with hypointense to intermediate signals on T2-weighted images and impeded diffusivity (water movement) on diffusion-weighted imaging (DWI), which could suggest a giant-cell-containing benign soft tissue tumor, despite the malignancy suggested by {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in a 35-year-old male. To our knowledge, this report introduces the first deep, solid giant cell tumor of soft tissue with MR features of a giant-cell-containing benign soft tissue tumor, despite the malignancy-mimicking findings on {sup 18}F-FDG PET-CT. (orig.)

  4. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    Science.gov (United States)

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  5. Therapeutic efficacy and microSPECT/CT imaging of {sup 188}Re-DXR-liposome in a C26 murine colon carcinoma solid tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y.-J.; Chang, C.-H.; Yu, C.-Y.; Chang, T.-J.; Chen, L.-C. [Institute of Nuclear Energy Research, Taoyuan, Taiwan (China); Chen, M.-H. [National Health Research Institutes, Miaoli, Taiwan (China); Lee, T.-W. [Institute of Nuclear Energy Research, Taoyuan, Taiwan (China); Ting Gann [National Health Research Institutes, Miaoli, Taiwan (China)], E-mail: gann.ting@msa.hinet.net

    2010-01-15

    Nanocarriers can selectively target cancer sites and carry payloads, thereby improving diagnostic and therapeutic effectiveness and reducing toxicity. The objective of this study was to investigate the therapeutic efficacy of a new co-delivery radiochemotherapeutics of {sup 188}Re-N,N-bis (2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA)-labeled pegylated liposomal doxorubicin (DXR) ({sup 188}Re-DXR-liposome) in a C26 murine colon carcinoma solid tumor model. To evaluate the targeting and localization of {sup 188}Re-DXR-liposome in C26 murine tumor-bearing mice, biodistribution, microSPECT/CT imaging and pharmacokinetic studies were performed. The antitumor effect of {sup 188}Re-DXR-liposome was assessed by tumor growth inhibition, survival ratio and histopathological hematoxylin-eosin staining. The tumor target and localization of the nanoliposome delivery radiochemotherapeutics of {sup 188}Re-DXR-liposome were demonstrated in the biodistribution, pharmacokinetics and in vivo nuclear imaging studies. In the study on therapeutic efficacy, the tumor-bearing mice treated with bimodality radiochemotherapeutics of {sup 188}Re-DXR-liposome showed better mean tumor growth inhibition rate (MGI) and longer median survival time (MGI=0.048; 74 days) than those treated with radiotherapeutics of {sup 188}Re-liposome (MGI=0.134; 60 days) and chemotherapeutics of Lipo-Dox (MGI=0.413; 38 days). The synergistic tumor regression effect was observed with the combination index (CI) exceeding 1 (CI=1.145) for co-delivery radiochemotherapeutics of {sup 188}Re-DXR-liposome. Two (25%) of the mice treated with radiochemotherapeutics were completely cured after 120 days. The therapeutic efficacy of radiotherapeutics of {sup 188}Re-liposome and the synergistic effect of the combination radiochemotherapeutics of {sup 188}Re-DXR-liposome have been demonstrated in a C26 murine solid tumor animal model, which pointed to the potential benefit and promise of the co-delivery of

  6. Evaluation of the tumor registration error in biopsy procedures performed under real-time PET/CT guidance.

    Science.gov (United States)

    Fanchon, Louise M; Apte, Adytia; Schmidtlein, C Ross; Yorke, Ellen; Hu, Yu-Chi; Dogan, Snjezana; Hatt, Mathieu; Visvikis, Dimitris; Humm, John L; Solomon, Stephen B; Kirov, Assen S

    2017-10-01

    The purpose of this study is to quantify tumor displacement during real-time PET/CT guided biopsy and to investigate correlations between tumor displacement and false-negative results. 19 patients who underwent real-time 18 F-FDG PET-guided biopsy and were found positive for malignancy were included in this study under IRB approval. PET/CT images were acquired for all patients within minutes prior to biopsy to visualize the FDG-avid region and plan the needle insertion. The biopsy needle was inserted and a post-insertion CT scan was acquired. The two CT scans acquired before and after needle insertion were registered using a deformable image registration (DIR) algorithm. The DIR deformation vector field (DVF) was used to calculate the mean displacement between the pre-insertion and post-insertion CT scans for a region around the tip of the biopsy needle. For 12 patients one biopsy core from each was tracked during histopathological testing to investigate correlations of the mean displacement between the two CT scans and false-negative or true-positive biopsy results. For 11 patients, two PET scans were acquired; one at the beginning of the procedure, pre-needle insertion, and an additional one with the needle in place. The pre-insertion PET scan was corrected for intraprocedural motion by applying the DVF. The corrected PET was compared with the post-needle insertion PET to validate the correction method. The mean displacement of tissue around the needle between the pre-biopsy CT and the postneedle insertion CT was 5.1 mm (min = 1.1 mm, max = 10.9 mm and SD = 3.0 mm). For mean displacements larger than 7.2 mm, the biopsy cores gave false-negative results. Correcting pre-biopsy PET using the DVF improved the PET/CT registration in 8 of 11 cases. The DVF obtained from DIR of the CT scans can be used for evaluation and correction of the error in needle placement with respect to the FDG-avid area. Misregistration between the pre-biopsy PET and the CT acquired with the

  7. CT images of an anthropomorphic and anthropometric male pelvis phantom

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  8. CT images of an anthropomorphic and anthropometric male pelvis phantom

    International Nuclear Information System (INIS)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de

    2009-01-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  9. DW MRI at 3.0 T versus FDG PET/CT for detection of malignant pulmonary tumors.

    Science.gov (United States)

    Zhang, Jian; Cui, Long-Biao; Tang, Xing; Ren, Xin-Ling; Shi, Jie-Ran; Yang, Hai-Nan; Zhang, Yan; Li, Zhi-Kui; Wu, Chang-Gui; Jian, Wen; Zhao, Feng; Ti, Xin-Yu; Yin, Hong

    2014-02-01

    Emerging evidence suggests that diffusion-weighted magnetic resonance imaging (DW MRI) could be useful for tumor detection with N and M staging of lung cancer in place of fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). DW MRI at 3.0 T and FDG PET/CT were performed before therapy in 113 patients with pulmonary nodules. Mean apparent diffusion coefficient (ADC), maximal standardized uptake value (SUVmax ) and Ki-67 scores were assessed. Quantitatively, specificity and accuracy of ADC (91.7 and 92.9%, respectively) were significantly higher than those of SUVmax (66.7 and 77.9% respectively, p 0.05). Qualitatively, sensitivity, specificity and accuracy of DW MRI (96.1, 83.3 and 92.0%, respectively) were also not significantly different from that of FDG PET/CT (88.3, 83.3 and 86.7%, respectively, p > 0.05). Significant negative correlation was found between Ki-67 score and ADC (r = -0.66, p 0.05). In conclusion, quantitative and qualitative assessments for detection of malignant pulmonary tumors with DW MRI at 3.0 T are superior to those with FDG PET/CT. Furthermore, ADC could predict the malignancy of lung cancer. © 2013 UICC.

  10. What is the difference in the hybrid imaging techniques - SPECT/CT and PET-CT and is there any advantage of their application?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods - Single Photon Emission Tomography-Computer Tomography /SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET- CT - positron emitters are applied, most often 18F and 11C, while in SPECT-CT - single photon emitters, most often 99m Tc and 131 I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumor. As a final result, compared to the conventional techniques - roentgenography, CT and MRI, it is possible in many cases to make an early and more precise diagnosis, saving patients' time and using most appropriate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase. (author)

  11. Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    Science.gov (United States)

    Dzyubak, Oleksandr; Kincaid, Russell; Hertanto, Agung; Hu, Yu-Chi; Pham, Hai; Rimner, Andreas; Yorke, Ellen; Zhang, Qinghui; Mageras, Gig S

    2014-10-01

    Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous retrospective study was limited to examination of reducing motion artifacts in a small number of patient cases. They report here on a prospective study in a larger group of lung cancer patients to evaluate respiratory motion-corrected (RMC)-CBCT ability to improve lung tumor localization accuracy and reduce motion artifacts in Linac-mounted CBCT images. A second study goal examines whether the motion correction derived from a respiration-correlated CT (RCCT) at simulation yields similar tumor localization accuracy at treatment. In an IRB-approved study, 19 lung cancer patients (22 tumors) received a RCCT at simulation, and on one treatment day received a RCCT, a respiratory-gated CBCT at end expiration, and a 1-min CBCT. A respiration monitor of abdominal displacement was used during all scans. In addition to a CBCT reconstruction without motion correction, the motion correction method was applied to the same 1-min scan. Projection images were sorted into ten bins based on abdominal displacement, and each bin was reconstructed to produce ten intermediate CBCT images. Each intermediate CBCT was deformed to the end expiration state using a motion model derived from RCCT. The deformed intermediate CBCT images were then added to produce a final RMC-CBCT. In order to evaluate the second study goal, the CBCT was corrected in two ways, one using a model derived from the RCCT at simulation [RMC-CBCT(sim)], the other from the RCCT at treatment [RMC-CBCT(tx)]. Image evaluation compared uncorrected CBCT, RMC-CBCT(sim), and RMC-CBCT(tx). The gated CBCT at end expiration served as the criterion standard for comparison. Using automatic rigid image registration, each CBCT was

  12. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images

    International Nuclear Information System (INIS)

    Koivula, Lauri

    2016-01-01

    Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm

  13. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images

    Energy Technology Data Exchange (ETDEWEB)

    Koivula, Lauri [Department of Radiation Oncology, Comprehensive Cancer Center, Helsinki University Central Hospital, P.O. Box 180, Helsinki 00029 HUS (Finland)

    2016-08-15

    Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm

  14. Dynamic contrast-enhanced CT in advanced lung cancer after chemotherapy with/within radiation therapy: Can it predict treatment responsiveness of the tumor?

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Mi Ri; Whang, Sung Ho; Park, Chul Hwan; Kim, Sang Jin; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the contrast enhancement patterns of lung cancer after chemotherapy using a dynamic contrast-enhanced (DCE) CT and to determine whether the enhancement patterns of tumors at early stages of treatment can predict treatment responses. Forty-two patients with advanced lung cancers underwent DCE-CT and follow-up CT after chemotherapy. We evaluated peak and net enhancement (PE and NE, respectively) and time-density curves (TDCs) (type A, B, C, and D) on DCE-CT images. Treatment responses were evaluated using revised Response Evaluation Criteria in Solid Tumor criteria. NE and PE values were significantly higher in the progressive disease (PD) groups than in the stable disease (SD) or partial response (PR) groups (p < 0.05). Types B, C, and D on TDCs were observed mostly in the PR and SD groups (96.0%), whereas type A was most frequent in the SD and PD groups (97.2%), which were significantly different in terms of PE and NE. Contrast enhancement pattern regarding the response of treatment on DCE-CT images could be helpful in predicting treatment response of advanced lung cancer after treatment.

  15. Cone-Beam CT Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumors: Comparison of Conventional and Dedicated-Software Analysis.

    Science.gov (United States)

    Ronot, Maxime; Abdel-Rehim, Mohamed; Hakimé, Antoine; Kuoch, Viseth; Roux, Marion; Chiaradia, Mélanie; Vilgrain, Valérie; de Baere, Thierry; Deschamps, Frédéric

    2016-01-01

    To compare the ability of dedicated software and conventional cone-beam computed tomography (CT) analysis to identify tumor-feeding vessels in hypervascular liver tumors treated with chemoembolization. Between January 2012 and January 2013, 45 patients (32 men, mean age of 61 y; range, 27-85 y) were enrolled, and 66 tumors were treated (mean, 32 mm ± 18; range, 10-81 mm) with conventional chemoembolization with arterial cone-beam CT. Data were independently analyzed by six interventional radiologists with standard postprocessing software, a computer-aided analysis with FlightPlan for liver (FPFL; ie, "raw FPFL"), and a review of this computer-aided FPFL analysis ("reviewed FPFL"). Analyses were compared with a reference reading established by two study supervisors in consensus who had access to all imaging data. Sensitivities, positive predictive values (PPVs), and false-positive (FP) ratios were compared by McNemar, χ(2), and Fisher exact tests. Analysis durations were compared by Mann-Whitney test, and interreader agreement was assessed. Reference reading identified 179 feeder vessels. The sensitivity of raw FPFL was significantly higher than those of reviewed FPFL and conventional analyses (90.9% vs 83.2% and 82.1%; P software enabled a fast, accurate, and sensitive detection of tumor feeder vessels. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  16. PET/CT imaging: The incremental value of assessing the glucose metabolic phenotype and the structure of cancers in a single examination

    International Nuclear Information System (INIS)

    Czernin, Johannes; Benz, Matthias R.; Allen-Auerbach, Martin S.

    2010-01-01

    PET/CT with the glucose analogue FDG is emerging as the most important diagnostic imaging tool in oncology. More than 2000 PET/CT scanners are operational worldwide and its unique role for diagnosing, staging, restaging and therapeutic monitoring in cancer is undisputed. Studies conducted in thousands of cancer patients have clearly indicated that the combination of molecular PET with anatomical CT imaging provides incremental diagnostic value over PET or CT alone. State of the art imaging protocols combine fully diagnostic CT scans with quality whole body PET surveys. The current review briefly describes the biological alterations of cancer cells that result in their switch to a strongly glycolytic phenotype. Different whole body imaging protocols are discussed. We summarize the evidence for the incremental value of PET/CT over CT and PET alone using imaging of sarcoma as an example. Following this section we discuss the performance of FDG-PET/CT imaging for staging, restaging and monitoring of head and neck cancer, solitary lung nodules and lung cancer, breast cancer, colorectal cancer, lymphoma and unknown primary tumors. Finally, the recently emerging evidence of a substantial impact of PET/CT imaging on patient management is presented.

  17. Algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images

    International Nuclear Information System (INIS)

    Ogino, Takashi; Egawa, Sunao

    1991-01-01

    New algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images were developed. One, designated plane weighting method, is to correct CT value in proportion to the position of the beam element passing through the voxel. The other, designated solid weighting method, is to correct CT value in proportion to the length of the beam element passing through the voxel and the volume of voxel. Phantom experiments showed fair spatial resolution in the transverse direction. In the longitudinal direction, however, spatial resolution of under slice thickness could not be obtained. Contrast resolution was equivalent for both methods. In patient studies, the reconstructed radiotherapy simulation image was almost similar in visual perception of the density resolution to a simulation film taken by X-ray simulator. (author)

  18. Prognostic factors of nasopharynx tumors investigated by MR imaging and the value of MR imaging in the newly published TNM staging

    International Nuclear Information System (INIS)

    Sakata, Koh-ichi; Hareyama, Masato; Tamakawa, Mituharu; Oouchi, Atushi; Sido, Mitsuo; Nagakura, Hisayasu; Akiba, Hidenari; Koito, Kazumitsu; Himi, Tetsuo; Asakura, Kohji

    1999-01-01

    Purpose: To examine the usefulness of MR imaging for predicting local control of nasopharyngeal carcinoma (NPC) and the value of MR imaging in the newly published fifth edition of the TNM classification. Methods and Materials: We studied 29 patients with NPC with MR imaging and CT before and after treatment. Staging was done according to the fourth and newly published fifth editions of the International Union Against Cancer (UICC) staging system. The radiotherapy protocol was designed to deliver 66 to 68 Gy to the primary tumor and clinically involved nodes. Results: MR proved better than CT at identifying obliteration of the pharyngobasilar fascia, invasion of the sinus of Morgagni, through which the cartilaginous portion of the eustachian tube and the levator veli palatini muscle pass, invasion of the skull base, and metastases to lymph nodes in the carotid and retropharyngeal spaces. All seven patients without invasion of the pharyngobasilar fascia had local control. The local control rates of patients with invasion of the skull base were not good (60 to 73%). There was no apparent relationship between tumor volume determined by T1-weighted MR images and local control when the tumor volume was more than 20 cc. The newly published N staging system appears to successfully identify the high-risk group for distant metastasis as N3. In our series, four of five patients with N3 disease developed distant metastases. Conclusion: Deep infiltration of the tumor is a more important prognostic factor in NPC than tumor volume. Since the newly published T staging system requires a search for tumor invasion into soft tissue such as parapharyngeal space and bony structures, MR imaging may be indispensable for the newly published NPC staging system

  19. Active contour based segmentation of resected livers in CT images

    Science.gov (United States)

    Oelmann, Simon; Oyarzun Laura, Cristina; Drechsler, Klaus; Wesarg, Stefan

    2015-03-01

    The majority of state of the art segmentation algorithms are able to give proper results in healthy organs but not in pathological ones. However, many clinical applications require an accurate segmentation of pathological organs. The determination of the target boundaries for radiotherapy or liver volumetry calculations are examples of this. Volumetry measurements are of special interest after tumor resection for follow up of liver regrow. The segmentation of resected livers presents additional challenges that were not addressed by state of the art algorithms. This paper presents a snakes based algorithm specially developed for the segmentation of resected livers. The algorithm is enhanced with a novel dynamic smoothing technique that allows the active contour to propagate with different speeds depending on the intensities visible in its neighborhood. The algorithm is evaluated in 6 clinical CT images as well as 18 artificial datasets generated from additional clinical CT images.

  20. Novel Hyaluronic Acid Conjugates for Dual Nuclear Imaging and Therapy in CD44-Expressing Tumors in Mice In Vivo

    Science.gov (United States)

    Dubey, Ravindra Dhar; Klippstein, Rebecca; Wang, Julie Tzu-Wen; Hodgins, Naomi; Mei, Kuo-Ching; Sosabowski, Jane; Hider, Robert C.; Abbate, Vincenzo; Gupta, Prem N.; Al-Jamal, Khuloud T.

    2017-01-01

    Hyaluronic acid, a natural CD44 receptor ligand, has attracted attention in the past years as a macromolecular delivery of anticancer agents to cancer. At the same time, the clinical applications of Gemcitabine (Gem) have been hindered by its short biological half-life, high dose and development of drug resistance. This work reports the synthesis of a hyaluronic acid (HA) conjugate for nuclear imaging, and in vivo Gem delivery to CD44-expressing solid tumors in mice. HA was individually conjugated, via amide coupling, to Gem (HA-Gem), 4'-(aminomethyl)fluorescein hydrochloride (HA-4'-AMF) or tris(hydroxypyridinone) amine (HA-THP) for cancer therapy, in vitro tracking or single photon emission computed tomography/computed tomography (SPECT/CT) imaging, respectively. Gem conjugation to HA was directly confirmed by nuclear magnetic resonance (1H NMR), gel permeation chromatography (GPC) and UV-visible spectrometry, or indirectly by a nucleoside transporter inhibition study. Gem conjugation to HA improved its plasma stability, reduced blood hemolysis and resulted in delayed cytotoxicity in vitro. Uptake inhibition studies in colon CT26 and pancreatic PANC-1 cells, by flow cytometry, revealed that uptake of fluorescent HA conjugate is CD44 receptor and macropinocytosis-dependent. Gamma scintigraphy and SPECT/CT imaging confirmed the relatively prolonged blood circulation profile and uptake in CT26 (1.5 % ID/gm) and PANC-1 (1 % ID/gm) subcutaneous tumors at 24 h after intravenous injection in mice. Four injections of HA-Gem at ~15 mg/kg, over a 28-day period, resulted in significant delay in CT26 tumor growth and prolonged mice survival compared to the free drug. This study reports for the first time dual nuclear imaging and drug delivery (Gem) of HA conjugates to solid tumors in mice. The conjugates show great potential in targeting, imaging and killing of CD44-over expressing cells in vivo. This work is likely to open new avenues for the application of HA