  1. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  2. C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions; Transarterielle Chemoperfusion und -embolisation thorakaler Neoplasmen mittels C-Arm CT

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.; Nour-Eldin, N.E.; Lehnert, T.; Mbalisike, E. [Klinikum der Johann-Wolfgang-Goethe-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany)

    2009-09-15

    -Bogen-System der neuesten Generation (Artis Zeego, Siemens AG, Erlangen). Die TACP wurde durchgefuehrt mit einer Rotation von 220 und einem Volumen von 150 ml (Kontrastmittel/NaCl im Verhaeltnis 1:2), Verzoegerung 2 s, Fluss 12 ml/s, die TPCE mit einem Volumen von 75 ml (Kontrastmittel/NaCl im Verhaeltnis 1:2), Verzoegerung 2 s, Fluss 3 ml/s. Bei der TPCE-C-Arm-CT konnte der Perfusionsgrad des Tumors evaluiert werden. Die Lipiodolbelegung korrelierte in der C-Arm-CT mit der postinterventionellen MSCT. In der TACP konnten die beteiligten Interkostalarterien visualisiert werden; bei 30% der Interventionen erfolgte eine Umpositionierung des Katheters fuer die folgende Intervention. Mittels C-Arm-CT lassen sich zusaetzliche Informationen ueber die vaskulaeren Charakteristiken und das Perfusionsverhalten der Lungenlaesionen gewinnen, die eine interventionelle Strategieaenderung in relevanter Patientenanzahl zur Folge haben. (orig.)

  3. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  4. C-arm CT for planning and guidance of extrahepatic embolizations

    International Nuclear Information System (INIS)

    Wacker, F.K.; Meissner, O.A.; Meyer, B.C.

    2009-01-01

    Interventional radiological vascular embolizations are complex procedures that require exact imaging of the target region to facilitate safe and effective treatment. The purpose of this paper is to present the technique and feasibility of flat detector C-arm computed tomography (C-arm CT) for control and guidance of extrahepatic abdominal embolization procedures. C-arm CT images can provide important information on both vascular and cross-sectional anatomy of the target region, help in determining therapy endpoints and provide follow-up during and immediately after the abdominal interventions.The cases presented demonstrate that C-arm CT images are beneficial for abdominal embolization procedures and facilitate precise treatment. (orig.) [de

  5. Percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma under C-arm cone beam CT guidance.

    Science.gov (United States)

    Amouyal, G; Pernot, S; Déan, C; Cholley, B; Scotté, F; Sapoval, M; Pellerin, O

    2017-11-01

    The aim of this study was to assess the feasibility, safety and efficacy of percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma using C-arm cone beam computed tomography (CBCT) guidance. This single-center prospective observational study was performed from August 2013 to August 2016, and included consecutive patients referred for radiofrequency ablation of lung metastases from colorectal cancer. Radiofrequency ablation procedures were performed under C-arm CBCT guidance. Feasibility was assessed by probe accuracy placement, time to accurate placement and number of C-arm CBCT acquisitions to reach the target lesion. Safety was assessed by the report of adverse event graded using the common terminology criteria for adverse events (CTCAE-V4.0). Efficacy was assessed by metastases response rate using RECIST 1.1 and 18 FDG-PET-CT tumor uptake at 6months. Fifty-four consecutive patients (32 men, 22 women) with a mean age of 63±8 (SD) years (range: 51-81years) with a total of 56 lung metastasis from colorectal metastases were treated in a single session. The mean tumor diameter was 25.6±4.5 (SD)mm (range: 17-31mm). Median time to insert the needle into the target lesion was 10min (range: 5-25min). Median number of needles repositioning and C-arm CBCT acquisition per patient was 1 (range: 0-3) and 4 (range: 3-6) respectively. The accuracy for radiofrequency ablation probe placement was 2±0.2 (SD)mm (range: 0-9mm). Pneumothorax requiring chest tube placement occurred in one patient (CTCAE-V4.0 grade 3). At 6months, all patients were alive with tumor response rate of -27% and had no significant activity on the 18 FDG-PET CT follow-up. Percutaneous radiofrequency ablation of lung metastases from colorectal cancer under C-arm CBCT guidance is feasible and safe, with immediate and short-term results similar to those obtained using conventional CT guidance. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS

  6. Diagnostic evaluatuin of gastrointestinal tumors; Diagnostik bei Tumoren im Gastrointestinaltrakt

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R.; Tatsch, K. [Ludwig-Maximilians-Univ. Muenchen (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1998-07-01

    difficult to distinguish between chronic pancreatitis and pancreatic carcinoma. In such cases a PET scan may be helpful. For planning of surgery and for preoperative staging morphological imaging is essential, but in nearly 40% of the patients nonresectable tumors were detected intraoperatively, which were not diagnosed by preoperative CT or MRI. PET seems to be more accurate in this respect, too. (orig.) [Deutsch] Hauptaufgaben der radiologischen und nuklearmedizinischen Diagnostik bei gastrointestinalen Tumoren sind Diagnosesicherung sowie praeoperatives Staging. Die Hohlorgane des oberen und unteren GI-Traktes (Oesophagus, Magen, Duodenum, Kolon, Rektum) werden primaer endoskopisch und endosonographisch abgeklaert. CT oder MRT liefern Informationen ueber Ausdehnung des Tumors, eine Infiltration in umgebende Strukturen und das Vorliegen pathologischer Lymphknoten. Das sensitivste Verfahren zum Nachweis von Lymphknoten- oder Fernmetastasen ist die PET. Auch die Differenzierung eines Lokalrezidivs von postoperativer Narbenbildung, z.B. beim kolorektalen Karzinom, gelingt mit der PET fruehzeitiger als mit den konventionellen morphologischen Verfahren. Lebertumoren sollten primaer sonographisch und bei fraglicher Dignitaet anschliessend mittels MRT untersucht werden. In der Differentialdiagnostik von unklaren Leberherden ist die nuklearmedizinische Rezeptorszintigraphie wegweisend. Benigne Leberlaesionen koennen mit der Neogalaktoalbumin-(NGA-)Szintigraphie sicher von malignen Tumoren (Metastasen, hepatozellulaeres Karzinom [HCC]) abgegrenzt werden, da NGA-Rezeptoren nur auf funktionstuechtigen Hepatozyten experimentiert werden. Die Unterscheidung von Lebermetastasen und dem HCC gelingt mit der Insulinszintigraphie, da sich Insulin aufgrund einer Ueberexpression von Insulinrezeptoren mit HCC vermehrt anreichert. Ergeben die vorgeschalteten Untersuchungen den Verdacht auf einen malignen Prozess, sollte zusaetzlich eine CT-Arterioportographie durchgefuehrt werden, da dieses

  7. Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy.

    Science.gov (United States)

    Pfaff, Johannes; Schönenberger, Silvia; Herweh, Christian; Pham, Mirko; Nagel, Simon; Ringleb, Peter Arthur; Heiland, Sabine; Bendszus, Martin; Möhlenbruch, Markus Alfred

    2017-09-01

    To achieve the fastest possible workflow in ischaemic stroke, we developed a CT/C-arm system, which allows imaging and endovascular treatment on the same patient table. This prospective, monocentric trial was conducted between October 2014 and August 2016. Patients received stroke imaging and mechanical thrombectomy under general anaesthesia (GA) or conscious sedation (CS) using our combined setup comprising a CT-scanner and a mobile C-arm X-ray device. Primary endpoint was time between stroke imaging and groin puncture. We compared periprocedural workflow and procedure times with the literature and a matched patient cohort treated with a biplane angiographic system before installation of the CT/C-arm system. In 50 patients with acute ischaemic stroke due to large-vessel occlusion in the anterior circulation, comparable recanalization rates were achieved by using the CT/C-arm setup (TICI2b-3:CT/C-arm-GA: 85.7%; CT/C-arm-CS: 90.9%; Angiosuite: 78.6%; p = 0.269) without increasing periprocedural complications. Elimination of patient transport resulted in a significant reduction of the time between stroke imaging and groin puncture: median, min (IQR): CT/C-arm-GA: 43 (35-52); CT/C-arm-CS: 39 (28-49); Angiosuite: 64 (48-74); p < 0.0001. The combined CT/C-arm system allows comparable recanalization rates as a biplane angiographic system and accelerates the start of the endovascular stroke treatment. • The CT/C-arm setup reduces median time from stroke imaging to groin puncture. • Mechanical thrombectomy using a C-arm device is feasible without increasing peri-interventional complications. • The CT/C-arm setup might be a valuable fallback solution for emergency procedures. • The CT/C-arm setup allows immediate control CT images during and after treatment.

  8. Utility of C-arm CT in overcoming challenges in patients undergoing Transarterial chemoembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kulkarni, Chinmay; Sreekumar, K. P.; Prabhu, Nirmal Kumar; Kannan, Rajesh R; Moorthy, Srikanth

    2014-01-01

    Transarterial chemoembolization (TACE) is the well-known treatment for hepatocellular carcinoma. Multiple digital subtraction angiography (DSA) acquisitions in different projections are required to identify difficult arterial feeders. Moreover, the tell-tale tumor blush can be obscured by proximity to lung base, small size of lesion, and breathing artifacts. C-arm CT is a revolutionary advancement in the intervention radiology suite that allows acquisition of data which can be reformatted in multiple planes and volume rendered incorporating both soft tissue and vascular information like multidetector computed tomography (MDCT). These images acquired during the TACE procedure can provide critical inputs for achieving a safe and effective therapy. This case series aims to illustrate the utility of C-arm CT in solving specific problems encountered while performing TACE

  9. Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Pfaff, Johannes; Herweh, Christian; Pham, Mirko; Heiland, Sabine; Bendszus, Martin; Moehlenbruch, Markus Alfred [University of Heidelberg, Department of Neuroradiology, Heidelberg (Germany); Schoenenberger, Silvia; Nagel, Simon; Ringleb, Peter Arthur [University of Heidelberg, Department of Neurology, Heidelberg (Germany)

    2017-09-15

    To achieve the fastest possible workflow in ischaemic stroke, we developed a CT/C-arm system, which allows imaging and endovascular treatment on the same patient table. This prospective, monocentric trial was conducted between October 2014 and August 2016. Patients received stroke imaging and mechanical thrombectomy under general anaesthesia (GA) or conscious sedation (CS) using our combined setup comprising a CT-scanner and a mobile C-arm X-ray device. Primary endpoint was time between stroke imaging and groin puncture. We compared periprocedural workflow and procedure times with the literature and a matched patient cohort treated with a biplane angiographic system before installation of the CT/C-arm system. In 50 patients with acute ischaemic stroke due to large-vessel occlusion in the anterior circulation, comparable recanalization rates were achieved by using the CT/C-arm setup (TICI2b-3:CT/C-arm-GA: 85.7%; CT/C-arm-CS: 90.9%; Angiosuite: 78.6%; p = 0.269) without increasing periprocedural complications. Elimination of patient transport resulted in a significant reduction of the time between stroke imaging and groin puncture: median, min (IQR): CT/C-arm-GA: 43 (35-52); CT/C-arm-CS: 39 (28-49); Angiosuite: 64 (48-74); p < 0.0001. The combined CT/C-arm system allows comparable recanalization rates as a biplane angiographic system and accelerates the start of the endovascular stroke treatment. (orig.)

  10. Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy

    International Nuclear Information System (INIS)

    Pfaff, Johannes; Herweh, Christian; Pham, Mirko; Heiland, Sabine; Bendszus, Martin; Moehlenbruch, Markus Alfred; Schoenenberger, Silvia; Nagel, Simon; Ringleb, Peter Arthur

    2017-01-01

    To achieve the fastest possible workflow in ischaemic stroke, we developed a CT/C-arm system, which allows imaging and endovascular treatment on the same patient table. This prospective, monocentric trial was conducted between October 2014 and August 2016. Patients received stroke imaging and mechanical thrombectomy under general anaesthesia (GA) or conscious sedation (CS) using our combined setup comprising a CT-scanner and a mobile C-arm X-ray device. Primary endpoint was time between stroke imaging and groin puncture. We compared periprocedural workflow and procedure times with the literature and a matched patient cohort treated with a biplane angiographic system before installation of the CT/C-arm system. In 50 patients with acute ischaemic stroke due to large-vessel occlusion in the anterior circulation, comparable recanalization rates were achieved by using the CT/C-arm setup (TICI2b-3:CT/C-arm-GA: 85.7%; CT/C-arm-CS: 90.9%; Angiosuite: 78.6%; p = 0.269) without increasing periprocedural complications. Elimination of patient transport resulted in a significant reduction of the time between stroke imaging and groin puncture: median, min (IQR): CT/C-arm-GA: 43 (35-52); CT/C-arm-CS: 39 (28-49); Angiosuite: 64 (48-74); p < 0.0001. The combined CT/C-arm system allows comparable recanalization rates as a biplane angiographic system and accelerates the start of the endovascular stroke treatment. (orig.)

  11. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  12. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  13. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    International Nuclear Information System (INIS)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  14. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Gyeonggi-do (Korea, Republic of); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Gyeonggi-do (Korea, Republic of)

    2011-04-15

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  15. SPECT/CT for staging and treatment monitoring in oncology. Applications in differentiated thyroid cancer and liver tumors; SPECT/CT zum initialen Staging und Therapiemonitoring in der Onkologie. Indikationen beim differenzierten Schilddruesenkarzinom und bei Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Weber, K.; Berger, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Mustafa, M.; Bartenstein, P.; Haug, A. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2012-07-15

    and SPECT/CT provides more accurate imaging of the arterial supply of the liver and of potential outflows of micro-spheres into other organs. SPECT/CT allows evaluation and quantification of the uptake of liver tumors. Improved postablative staging in patients with differentiated thyroid cancer by SPECT/CT in comparison to radioiodine whole body scans can be achieved. Improved planning and monitoring of SIRT therapies utilizing SPECT/CT leads to optimized therapeutic doses within liver lesions. Integration of SPECT/CT into the clinical standard for postablative staging in patients with DTC is recommended as well as utilization of SPECT/CT during the planning process, for dose calculation and treatment monitoring of SIRT therapies. (orig.) [German] In den letzten Jahren hat die Hybridbildgebung mit Verbindung von funktioneller und morphologischer Information zur Diagnostik zahlreicher Erkrankungen zunehmend an Bedeutung gewonnen. Bei Patienten mit differenziertem Schilddruesenkarzinom (DTC) wird nach erfolgter Radiojodtherapie (RJT) ein planares Ganzkoerperszintigramm zum Staging durchgefuehrt. Die diagnostische Genauigkeit dieser szintigraphischen Methode ist jedoch aufgrund limitierter raeumlicher Aufloesung begrenzt. Die Radioembolisation von mit {sup 90}Yttrium beladenen Mikrosphaeren (selektive interne Radiotherapie, SIRT) ermoeglicht eine wenig invasive Therapie primaerer und sekundaerer Lebertumoren. Zur Vermeidung von Nebenwirkungen der Mikrosphaeren durch einen Abstrom in Darm, Magen und Lunge muss vor Therapiebeginn eine Darstellung des durch die leberversorgenden Arterien versorgten Gebiets mittels {sup 99m}Tc-MAA ({sup 99m}Technetium-makroaggregiertes Albumin) und einer Szintigraphie erfolgen. Auch hier limitiert die begrenzte morphologische Information der Szintigraphie das Therapiemonitoring. {sup 131}Jod-Ganzkoerperszintigramm zum Nachweis einer erfolgreichen Ablation und Staging ca. 3-4 Tage postablativ bei Patienten mit DTC. Ueberwachung des

  16. CT urography in women with primary or recurrent pelvic tumors. Background and initial experiences; CT-Urographie bei Frauen mit primaeren oder rezidivierenden Beckentumoren. Hintergrund und erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Seifert, S.; Mueller-Lisse, U.G.; Degenhart, C.; Mourched, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Jundt, K. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Klinik und Poliklinik fuer Gynaekologie und Geburtshilfe, Muenchen (Germany); Stief, C.G.; Mueller-Lisse, U.L. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Klinik und Poliklinik fuer Urologie, Muenchen (Germany)

    2011-07-15

    Malignant tumors of the female pelvis account for 12-13% of newly diagnosed solid neoplasms among women in the USA and Germany. German guidelines advocate diagnostic imaging for local recurrence and metastasis while there are no recommendations for primary tumors. As excretory urography has been replaced by the excretory phase of computed tomography urography (CTU) in many institutions, two independent observers retrospectively evaluated CTUs of primary or recurrent female pelvic tumors to rule out associations between CTU findings and subsequent urologic measures. Among 31 CTUs of 27 women (age 29-84 years, mean 57 years) with 15 primary and 13 recurrent tumors, 83-100% of unremarkable proximal, middle and distal ureter segments were completely delineated in the excretory phase (delay 6-29 min, mean 16 min). The most common pathological findings included distal ureter obstruction (n=19, 61%), bladder compression (n=13, 42%) and bladder invasion (n=8, 26%). Out of 20 pathologically altered urinary tracts 8 were subsequently subjected to urologic measures (2-tailed Fisher exact test, p=0.0215) but none of the 10 unremarkable urinary tracts were treated. It appears that CTU is a sensible pre-therapeutic test for the urinary tract for primary and recurrent female pelvic tumors. (orig.) [German] Maligne Beckentumoren stellen 12-13% aller neu diagnostizierten soliden Neoplasien bei Frauen in den USA und in Deutschland dar. Deutsche Leitlinien befuerworten bildgebende Untersuchungen bei Lokalrezidiven und Metastasen; fuer Primaertumoren gibt es keine einschlaegigen Empfehlungen. Da das Ausscheidungsurogramm durch die Ausscheidungsaufnahme der CT-Urographie (CTU) weitgehend abgeloest ist, wurde bei weiblichen Beckentumoren oder deren Rezidive der Zusammenhang zwischen CTU-Befunden und nachfolgenden operativen urologischen Massnahmen retrospektiv von 2 unabhaengigen Auswertern geprueft. Bei 31 CTUs von 27 Frauen (Alter 29-84, Median 57 Jahre) mit 15 Primaertumoren und 13

  17. Intra-operative adjustment of standard planes in C-arm CT image data.

    Science.gov (United States)

    Brehler, Michael; Görres, Joseph; Franke, Jochen; Barth, Karl; Vetter, Sven Y; Grützner, Paul A; Meinzer, Hans-Peter; Wolf, Ivo; Nabers, Diana

    2016-03-01

    With the help of an intra-operative mobile C-arm CT, medical interventions can be verified and corrected, avoiding the need for a post-operative CT and a second intervention. An exact adjustment of standard plane positions is necessary for the best possible assessment of the anatomical regions of interest but the mobility of the C-arm causes the need for a time-consuming manual adjustment. In this article, we present an automatic plane adjustment at the example of calcaneal fractures. We developed two feature detection methods (2D and pseudo-3D) based on SURF key points and also transferred the SURF approach to 3D. Combined with an atlas-based registration, our algorithm adjusts the standard planes of the calcaneal C-arm images automatically. The robustness of the algorithms is evaluated using a clinical data set. Additionally, we tested the algorithm's performance for two registration approaches, two resolutions of C-arm images and two methods for metal artifact reduction. For the feature extraction, the novel 3D-SURF approach performs best. As expected, a higher resolution ([Formula: see text] voxel) leads also to more robust feature points and is therefore slightly better than the [Formula: see text] voxel images (standard setting of device). Our comparison of two different artifact reduction methods and the complete removal of metal in the images shows that our approach is highly robust against artifacts and the number and position of metal implants. By introducing our fast algorithmic processing pipeline, we developed the first steps for a fully automatic assistance system for the assessment of C-arm CT images.

  18. Understanding the scatter radiation distribution during C-arm CT examination. A body phantom study

    International Nuclear Information System (INIS)

    Norimasa, Toshiyo; Kakimi, Akihiko; Takao, Yoshinori; Sasaki, Shohei; Katayama, Yutaka; Himoto, Daisuke; Izuta, Shinichiro; Ichida, Takao

    2016-01-01

    The purpose of this study was to understand the scatter radiation distribution during C-arm CT examination in the interventional radiography (IVR) room to show the escaped area and the radiation protective method. The C-arm rotates 200deg in 5 s. The tube voltage was 90 kV, and the entrance dose to the detector was 0.36 μGy/frame during C-arm CT examination. The scattered doses were measured each 50 cm from the isocenter like a grid pattern. The heights of the measurement were 50, 100, and 150 cm from the floor. The maximum scattered doses were 38.23 ± 0.60 μGy at 50 cm, 43.86 ± 20 μGy at 100 cm, and 25.78 ± 0.37 μGy at 150 cm. The scatter radiation distribution at 100 cm was the highest scattered dose. The operator should protect their reproductive gland, thyroid, and lens. The scattered dose was low behind the C-arm body and the bed, so they will be able to become the escaped area for staff. (author)

  19. Developing low-dose C-arm CT imaging for temporomandibular joint (TMJ) disorder in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaowei; Cahill, Anne Marie [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Felice, Marc [University of Pennsylvania, Environmental Health and Radiation Safety, Philadelphia, PA (United States); Johnson, Laura [Computed Tomography Division, Siemens Healthcare Sector, Shanghai (China); Sarmiento, Marily [Siemens Medical Solutions, Angiography and X-ray Division, Hoffman Estates, IL (United States)

    2011-04-15

    Manufacturers have provided C-arm CT imaging technologies for applications in interventional radiology in recent years. However, clinical imaging protocols and radiation doses have not been well studied or reported. The purpose of this study is to develop low-dose settings for clinically acceptable CT imaging of temporomandibular joint in interventional radiology suites, using a C-arm imaging angiography system. CT scans were performed with a flat-panel digital C-arm angiographic system on a 5-year-old anthropomorphic phantom. The CTDI was determined for various rotation times, dose settings and Cu filter selections. The CTDI values were compared with those of conventional low-dose CT for the same phantom. The effectiveness of using Cu filters to reduce dose was also investigated. Images were reviewed by a senior radiologist for clinical acceptance. The manufacturer's default setting gave an equivalent CTDI of 4.8 mGy. Optimizing the dose settings and adding copper filtration reduced the radiation dose by 94%. This represents a 50% reduction from conventional CT. Use of Cu filters and low-dose settings significantly reduced radiation dose from that of standard settings. This phantom study process successfully guided the clinical implementation of low-dose studies for all ages at our institution. (orig.)

  20. Imaging diagnostics of breast metastases from extramammary tumors; Bildgebende Diagnostik bei Brustmetastasen extramammaerer Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, S.; Lotz, J. [Georg-August-Universitaet Goettingen, Institut fuer Diagnostische und Interventionelle Radiologie, Goettingen (Germany); Nemat, S. [Universitaet Homburg/Saar, Institut fuer Diagnostische und Interventionelle Radiologie, Homburg/Saar (Germany); Surov, A. [Universitaet Leipzig, Institut fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany)

    2017-06-15

    Breast metastases of solid extramammary tumors are very rare in comparison to primary malignancies of the breast and account for only 0.33-6.3% of all malignant neoplasms of the breast. The most common primary tumors are malignant melanoma, distant sarcomas, lung cancer, ovarian cancer, renal cell cancer and thyroid cancer in decreasing order of frequency. This review article summarizes the clinical features and the different imaging findings of breast metastases from different extramammary solid tumors. Breast metastases are often incidental findings in computed tomography (CT) or positron emission tomography CT (PET-CT) imaging. Mammography shows two different imaging patterns, namely focal lesions and diffuse architectural distortion with skin thickening. Breast metastases presenting as focal masses usually occur as solitary and more rarely as multiple round lesions with a smooth edge boundary. Associated calcifications are rare findings. Diffuse architectural distortion with skin thickening is more common in breast metastases from most gastric tumors, ovarian cancer and rhabdomyosarcoma. Using ultrasound most lesions are hypoechoic, oval or round with smooth boundaries and posterior acoustic enhancement. The magnetic resonance imaging (MRI) criteria of breast metastases show an inconstant signal behavior that cannot be safely classified as benign or malignant. In summary, in patients with known malignancies the presence of breast metastases should be considered even with imposing clinically and radiologically benign findings. (orig.) [German] Brustmetastasen solider extramammaerer Tumoren sind im Vergleich zu primaeren Malignomen der Brust mit einer Praevalenz von 0,33-6,3 % aller boesartigen Neubildungen in der Brust sehr selten. Die haeufigsten Primaertumoren sind dabei das maligne Melanom, ferner Sarkome, Bronchial-, Ovarial-, Nierenzell- und Schilddruesenkarzinome mit einer absteigenden Haeufigkeit ihres Auftretens. In dieser Uebersichtsarbeit werden die

  1. PET in diagnosing exocrine pancreatic cancer; PET bei Tumoren des exokrinen Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Bares, R.; Besenfelder, H.; Dohmen, B.M. [Abt. Nuklearmedizin, Radiologische Klinik des Universitaetsklinikums Tuebingen (Germany)

    2003-06-01

    Despite dramatic improvements in diagnostic imaging (ultrasonography, in particular endoscopic ultrasound, CT, MRI) treatment results of pancreatic cancer are still poor. Due to the lack of early symptoms, most tumors are diagnosed at an advanced stage of disease which excludes curative surgical treatment. FDG-PET has been shown to be effective in detecting pancreatic cancer as well as differentiating benign from malignant pancreatic tumors. Results might be further improved by applying quantitative analyses, in particular kinetic modelling of FDG metabolism. Nevertheless false negative as well as false positive findings may occur. Small lesions (lymphnode or liver metastases < 1 cm) might be missed, furthermore hyperglycemia often present in patients with pancreatic disease might reduce tumor uptake and subsequently tumor detectability by PET. False positive findings were reported in active pancreatitis and some benign tumors. Although PET proved to be superior to CT or ERCP in detecting cancer, clinical relevance of PET is limited due to the absence of therapeutic consequences to be derived from PET. As a consequence PET should only be used in patients with equivocal findings of morphological imaging (CT, ERCP) who are potential candidates for surgical treatment. (orig.) [German] Trotz verbesserter diagnostischer Moeglichkeiten (endoskopischer Ultraschall, Spiral-CT, MRT) sind die Behandlungsergebnisse bei Tumoren des exokrinen Pankreas nach wie vor unbefriedigend. Aufgrund der spaet einsetzenden klinischen Symptomatik wird die Diagnose meist erst bei lokaler Inoperabilitaet gestellt. Die FDG-PET has sich sowohl im Nachweis von Pankreaskarzinomen als auch bei der Differenzialdiagnose pankreatischer Raumforderungen bewaehrt und den etablierten bildgebenden Verfahren (Ultraschall, CT) als ueberlegen erwiesen. Weitere Verbesserungen erscheinen durch absolute Quantifizierung der FDG-Kinetik moeglich. Dennoch koennen falsch negative wie auch falsch positive Ergebnisse

  2. Significance of CT analysis of regional lymph node metastases in colorectal cancer; Bedeutung der CT fuer die Beurteilung regionaerer Lymphknotenmetastasen bei kolorektalen Karzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Gomille, T.; Christ, F. [Duesseldorf Univ. (Germany). Abt. fuer Radiologie und Nuklearmedizin; Aleksic, M.; Ulrich, B. [Krankenhaus Gerresheim (Germany). Chirurgische Klinik

    1998-12-01

    Purpose: For preoperative staging of colorectal cancer a CT scan is frequently performed. This report examines the sensitivity of CT for regional lymph node metastasis of colorectal cancer using different criteria. Materials and methods: Preoperative CT scans of 153 patients with colorectal cancer were analyzed using different criteria for N1. The results were then compared to the postoperative histological findings. Results: For N1=lymph nodes (LN)>1 cm the sensitivity was 47%. For N1=LN>1 cm or an increased number of LN<1 cm the sensitivity was 71%. In patients with a primary tumor seen on CT, sensitivity rose to 87%. Discussion: Evidence of regional nodal metastatic disease is only relevant for rectal cancer, colon polyps, and for locally excised tumors when considering present surgical concepts for the treatment of colorectal cancer. In these cases CT analysis using the broadened criteria for N1 proposes a valuable argument regarding possible preoperative radiotherapy or an operative revision. (orig.) [Deutsch] Die Sensitivitaet fuer den Nachweis regionaerer Lymphknotenmetastasen kolorektaler Karzinome wurde unter Anwendung verschiedener Kriterien fuer das N1-Stadium an Patienten mit histologisch gesichertem Lymphknotenbefund untersucht. Fuer das Kriterium N1=Lymphknoten (LK)>1 cm betrug die Sensitivitaet 47%. Fuer N1=LK>1 cm/vermehrte Anzahl LK<1 cm war sie 71%, bei erkennbarem Primaertumor sogar 87%. Unter Beruecksichtigung der derzeit geltenden operativen Therapiekonzepte ist der Nachweis von regionaeren Lymphknotenmetastasen nur bei Rektumkarzinom bzw. fuer Kolonpolypen oder fuer lokal exzidierte Karzinome fuer das therapeutische Vorgehen relevant. In diesen Faellen leistet die CT mit den erweiterten Kriterien fuer ein N1-Stadium trotz hoeherer falsch-positiver Raten eine wertvolle Hilfestellung fuer die Entscheidung ueber eine neoadjuvante Bestrahlung oder eine Nachresektion. (orig.)

  3. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  4. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Groezinger, Gerd; Maurer, Michael; Grosse, Ulrich; Horger, Marius; Nikolaou, Konstantin; Syha, Roland [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lauer, Ulrich M. [University of Tuebingen, Internal Medicine I, Department of Gastroenterology, Hepatology and Infectious disease, Tuebingen (Germany)

    2016-12-15

    Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. (orig.)

  5. Radiotherapy for a cystadenolymphoma of the parotid gland (Warthin's tumor); Radiotherapie bei einem Zystadenolymphom der Parotis (Warthin-Tumor)

    Energy Technology Data Exchange (ETDEWEB)

    Stallmann, C; Vacha, P; Vesely, H; Richter, E; Feyerabend, T [Medizinische Univ., Luebeck (Germany). Klinik fuer Strahlentherapie und Nuklearmedizin

    2001-05-01

    sind zystisch erweiterte Gangsysteme aus Epithelzellen sowie ein lymphoides Stroma. Die lymphoide Komponente wird als strahlensensibel beschrieben, waehrend der epitheliale Anteil deutlich schlechter reagiert. Seit 1960 ist lediglich ein einziger Fall publiziert worden, bei dem eine primaere Bestrahlung durchgefuehrt wurde. Fallbeschreibung: Bei einer 77-jaehrigen Patientin bestand ein Zystadenolymphom mit einem Maximaldurchmesser von 7 cm. Aufgrund der Ausdehnung und des schlechten Allgemeinzustands war eine Operation nicht moeglich. Wir fuehren eine Radiatio nach CT-Planung mit fuenfmal 2 Gy pro Woche bis zu einer Gesamtdosis von 50 Gy durch. Nach 30 Gy war der Tumor klinisch, 6 Wochen nach Abschluss der Bestrahlung auch CT-morphologisch nicht mehr nachweisbar. Kontrollen nach 6 und 12 Monaten bestaetigten die Vollremission. Epikrise: Das oben beschriebene Zystadenolymphom war mit 7 cm Durchmesser ungewoehnlich gross. Durch eine Strahlentherapie mit 50 Gy kam es zu einer kompletten Tumorrueckbildung. Wie das gute klinische Ansprechen nach 30 Gy nahe legt, ist die erforderliche Dosis bei weniger ausgedehnten Zystadenolymphomen moeglicherweise niedriger. Schlussfolgerung: Eine Bestrahlung mit 50 Gy fuehrte im vorliegenden Fall zur anhaltenden Vollremission. Aufgrund der fehlenden Literatur kann eine allgemeine Empfehlung zur Gesamtdosis derzeit nicht gegeben werden. In folgenden Situationen sollte eine strahlentherapeutische Behandlung erwogen werden. 1. Erhoehtes Operationsrisiko fuer eine Fazialisschaedigung, 2. erhebliche kosmetische Beeintraechtigung durch eine Operation, 3. internistische Inoperabilitaet, 4. Operationsverweigerer. (orig.)

  6. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

    Science.gov (United States)

    Hua, Chiaho; Yao, Weiguang; Kidani, Takao; Tomida, Kazuo; Ozawa, Saori; Nishimura, Takenori; Fujisawa, Tatsuya; Shinagawa, Ryousuke; Merchant, Thomas E

    2017-11-01

    A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. The position accuracy and repeatability of the robotic C-arm was high (robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.

  7. Adjuvant chemo- and radiotherapy in gastrointestinal tumors; Adjuvante Chemo- und Strahlentherapie bei gastrointestinalen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Sendler, A. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik; Feldmann, H.J. [Technische Univ. Muenchen (Germany). Inst. und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Fink, U. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik; Molls, M. [Technische Univ. Muenchen (Germany). Inst. und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Siewert, J.R. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik

    1995-04-21

    In modern surgical oncology, adjuvant therapies are important complementary strategies. In local advanced carcinomas of the gastrointestinal tract, 5-year survival data are still disappointing despite standardized surgery. In this context, it has to be differentiated between adjuvant therapy following complete tumor exstirpation (so-called UICC R{sub 0} resection) and additive therapies following incomplete tumor resections (UICC R{sub 1} or R{sub 2} resection). Modalities in the adjuvant setting are chemotherapy, radiotherapy or the combined radio-/chemotherapy. In esophageal and gastric cancer there is up to now no benefit of postoperative adjuvant therapy. In pancreatic cancer, there are studies indicating a benefit of combined radio-/chemotherapy after complete tumor resection. A standard adjuvant chemotherapeutic treatment is proven in colon cancer stage III (Dukes C) with levamisole and 5-FU. Completely resected rectal carcinoma should be treated postoperatively with combined radio-/chemotherapy. In the common clinical or practical setting, adjuvant therapy is indicated only in locally advanced gastrointestinal tumors following R{sub 0} resection. Postoperative therapy following incomplete tumor resection has its reason only in a palliative intention. (orig.) [Deutsch] Adjuvante Therapiestrategien sind wichtige flankierende Massnahmen der modernen onkologischen Chirurgie, da u.a. die 5-Jahres-Ueberlebensquoten bei lokal fortgeschrittenen Tumoren des Gastrointestinaltraktes nach wie vor unbefriedingend sind. Dabei muss grundsaetzlich zwischen adjuvanten Behandlungen nach kompletter Tumorexstirpation (UICC-R{sub 0}-Resektion) und der additiven Therapie nach palliativer Resektion (UICC-R{sub 1}- oder -R{sub 2}-Resektion) unterschieden werden. Als Modalitaeten kommen Chemotherapie, Strahlentherapie und ihre Kombination in Frage. Bei Oesophagus- und Magenkarzinomen kann derzeit keine gueltige Empfehlung zur adjuvanten Therapie gegeben werden. Die Radio

  8. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

    International Nuclear Information System (INIS)

    Wang, Adam S; Stayman, J Webster; Otake, Yoshito; Siewerdsen, Jeffrey H; Kleinszig, Gerhard; Vogt, Sebastian; Gallia, Gary L; Khanna, A Jay

    2014-01-01

    The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40–80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4–2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose. (paper)

  9. Radiotherapy for a cystadenolymphoma of the parotid gland (Warthin's tumor); Radiotherapie bei einem Zystadenolymphom der Parotis (Warthin-Tumor)

    Energy Technology Data Exchange (ETDEWEB)

    Stallmann, C.; Vacha, P.; Vesely, H.; Richter, E.; Feyerabend, T. [Medizinische Univ., Luebeck (Germany). Klinik fuer Strahlentherapie und Nuklearmedizin

    2001-05-01

    Kennzeichen sind zystisch erweiterte Gangsysteme aus Epithelzellen sowie ein lymphoides Stroma. Die lymphoide Komponente wird als strahlensensibel beschrieben, waehrend der epitheliale Anteil deutlich schlechter reagiert. Seit 1960 ist lediglich ein einziger Fall publiziert worden, bei dem eine primaere Bestrahlung durchgefuehrt wurde. Fallbeschreibung: Bei einer 77-jaehrigen Patientin bestand ein Zystadenolymphom mit einem Maximaldurchmesser von 7 cm. Aufgrund der Ausdehnung und des schlechten Allgemeinzustands war eine Operation nicht moeglich. Wir fuehren eine Radiatio nach CT-Planung mit fuenfmal 2 Gy pro Woche bis zu einer Gesamtdosis von 50 Gy durch. Nach 30 Gy war der Tumor klinisch, 6 Wochen nach Abschluss der Bestrahlung auch CT-morphologisch nicht mehr nachweisbar. Kontrollen nach 6 und 12 Monaten bestaetigten die Vollremission. Epikrise: Das oben beschriebene Zystadenolymphom war mit 7 cm Durchmesser ungewoehnlich gross. Durch eine Strahlentherapie mit 50 Gy kam es zu einer kompletten Tumorrueckbildung. Wie das gute klinische Ansprechen nach 30 Gy nahe legt, ist die erforderliche Dosis bei weniger ausgedehnten Zystadenolymphomen moeglicherweise niedriger. Schlussfolgerung: Eine Bestrahlung mit 50 Gy fuehrte im vorliegenden Fall zur anhaltenden Vollremission. Aufgrund der fehlenden Literatur kann eine allgemeine Empfehlung zur Gesamtdosis derzeit nicht gegeben werden. In folgenden Situationen sollte eine strahlentherapeutische Behandlung erwogen werden. 1. Erhoehtes Operationsrisiko fuer eine Fazialisschaedigung, 2. erhebliche kosmetische Beeintraechtigung durch eine Operation, 3. internistische Inoperabilitaet, 4. Operationsverweigerer. (orig.)

  10. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  11. Clinically relevant incidental cardiovascular findings in CT examinations; Klinisch relevante kardiovaskulaere Zufallsbefunde bei CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A. [Universitaetsklinikum Leipzig, Klinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Schramm, D.; Bach, A.G. [Universitaetsklinikum Halle (Saale), Klinik fuer Radiologie, Halle (Germany)

    2017-04-15

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [German] Inzidentelle kardiovaskulaere Befunde sind ein haeufiges Phaenomen bei CT-Untersuchungen. Mit dieser Arbeit soll nach gezielter PubMed-Recherche ein systematischer Literaturueberblick ueber die wichtigsten kardiovaskulaeren Zufallsbefunde sowie deren Haeufigkeit und klinische Relevanz gegeben werden. Die Mehrzahl der inzidentellen kardiovaskulaeren Befunde sind klinisch nur von untergeordneter Bedeutung, allerdings werden immer wieder auch hochgradig relevante Zufallsbefunde wie beispielsweise Aortenaneurysmata oder - gerade bei onkologischen Patienten - Thrombosen und thrombembolische Ereignisse detektiert. Jede CT-Untersuchung sollte gezielt nach inzidentellen Befunden durchsucht werden, da diese je nach klinischer Relevanz von entscheidender Bedeutung fuer das weitere klinische Management des Patienten sein koennen. (orig.)

  12. Intraoperative imaging for patient safety and QA: detection of intracranial hemorrhage using C-arm cone-beam CT

    Science.gov (United States)

    Schafer, Sebastian; Wang, Adam; Otake, Yoshito; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Xia, Xuewei; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2013-03-01

    Intraoperative imaging could improve patient safety and quality assurance (QA) via the detection of subtle complications that might otherwise only be found hours after surgery. Such capability could therefore reduce morbidity and the need for additional intervention. Among the severe adverse events that could be more quickly detected by high-quality intraoperative imaging is acute intracranial hemorrhage (ICH), conventionally assessed using post-operative CT. A mobile C-arm capable of high-quality cone-beam CT (CBCT) in combination with advanced image reconstruction techniques is reported as a means of detecting ICH in the operating room. The system employs an isocentric C-arm with a flat-panel detector in dual gain mode, correction of x-ray scatter and beam-hardening, and a penalized likelihood (PL) iterative reconstruction method. Performance in ICH detection was investigated using a quantitative phantom focusing on (non-contrast-enhanced) blood-brain contrast, an anthropomorphic head phantom, and a porcine model with injection of fresh blood bolus. The visibility of ICH was characterized in terms of contrast-to-noise ratio (CNR) and qualitative evaluation of images by a neurosurgeon. Across a range of size and contrast of the ICH as well as radiation dose from the CBCT scan, the CNR was found to increase from ~2.2-3.7 for conventional filtered backprojection (FBP) to ~3.9-5.4 for PL at equivalent spatial resolution. The porcine model demonstrated superior ICH detectability for PL. The results support the role of high-quality mobile C-arm CBCT employing advanced reconstruction algorithms for detecting subtle complications in the operating room at lower radiation dose and lower cost than intraoperative CT scanners and/or fixedroom C-arms. Such capability could present a potentially valuable aid to patient safety and QA.

  13. Reduced-dose C-arm computed tomography applications at a pediatric institution

    Energy Technology Data Exchange (ETDEWEB)

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2017-12-15

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance. (orig.)

  14. Positron emission tomography in urological cancer; Positronenemissionstomographie bei urologischen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Wit, M. de [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Onkologie/Haematologie, Medizinische Klinik; Kotzerke, J. [Universitaetsklinikum Ulm (DE). Radiologie III (Nuklearmedizin)

    2000-09-01

    In staging cancer of the urinary bladder, the kidneys and the prostate and of testicular cancer there is a need for detecting tumor involvement of the lymph nodes to avoid surgical exploration. Positron emission tomography (PET) using fluorodeoxyglucose (FDG) can detect tumorous lymph nodes (sensitivity: 70%, specificity: 85%) which is helpful for several patients. In carcinoma of the prostate, other radiotracers than FDG (e.g. C-11-choline) might be more sensitive to detect tumorous lymph nodes. Up to now no diagnostical benefit of PET in germ cell tumors could be demonstrated in the published small series. In principle FDG-PET is useful in diagnosis of recurrence. In germ cell cancer FDG-PET seems to identify effectively persistent vital tumor tissue after chemotherapy. A multicenter study was initiated to demonstrate the potential of FDG-PET in a sufficient number of patients with germ cell tumor. (orig.) [German] Bei Harnblasen-, Nieren-, Prostata- und Hodenkarzinomen besteht aus klinischer Sicht ein Bedarf an verbessertem Lymphknoten-Staging, um die operative Evaluation zu vermeiden. Die Positronenemissionstomographie (PET) mit Fluordeoxyglukose (FDG) kann daher im Einzelfall bei Harnblasen- und Nierenkarzinomen hilfreich sein (bei Sensitivitaet um 70% und Spezifitaet um 85%). Beim Prostatakarzinom koennten sich andere Radiotracer (z.B. C-11-Cholin) bei der Detektion von tumoroesen Lymphknoten ueberlegen erweisen. Bei Keimzelltumoren konnte ein Nutzen der PET im primaeren Staging bei den bisher publizierten kleinen Studien nicht nachgewiesen werden. Fuer die Rezidivdiagnostik ist bei den genannten Tumoren aus grundsaetzlicher Ueberlegung der Einsatz von DFG-PET sinnvoll. Die Erkennung von vitalem malignen Tumorgewebe nach Chemotherapie erscheint bei Keimzelltumoren mit FDG-PET weitgehend sicher zu gelingen. Eine multizentrische Studie wurde begonnen, die hierueber Aufschluss geben wird. (orig.)

  15. Novel Tetra-Primer ARMS-PCR Assays for Thiopurine Intolerance Susceptibility Mutations NUDT15 c.415C>T and TPMT c.719A>G (TPMT*3C in East Asians

    Directory of Open Access Journals (Sweden)

    Chi-Chun Ho

    2017-10-01

    Full Text Available Thiopurines are clinically useful in the management of diverse immunological and malignant conditions. Nevertheless, these purine analogues can cause lethal myelosuppression, which may be prevented by prospective testing for variants in the thiopurine S-methyltransferase (TPMT and, in East Asians, Nudix hydrolase 15 (NUDT15 genes. Two single-tube, tetra-primer amplification refractory mutation system polymerase chain reaction (ARMS-PCR assays were developed to genotype the common loss-of-function variants NUDT15 c.415C>T (rs116855232 and TPMT*3C c.719A>G (rs1142345. In a group of 60 unselected patients, one and seven were found to be homozygous and heterozygous, respectively, for NUDT15 c.415C>T; one was found to be heterozygous for TPMT*3C c.719A>G. There was no non-specific amplification, and the genotypes were 100% concordant with Sanger sequencing. Limit-of-detection for both assays was below 1 ng of heterozygous template per reaction. Time- and cost-effective ARMS-PCR assays, suitable for genotyping East-Asian patients for thiopurine intolerance, were successfully developed and validated.

  16. Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, S.; Stayman, J.W.; Zbijewski, W.; Schmidgunst, C.; Kleinszig, G.; Siewerdsen, J.H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Siemens Healthcare XP Division, Erlangen, Bavaria 91052 (Germany); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States) and Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2012-01-15

    Purpose: X-ray scatter is a major detriment to image quality in cone-beam CT (CBCT). Existing geometries exhibit strong differences in scatter susceptibility with more compact geometries, e.g., dental or musculoskeletal, benefiting from antiscatter grids, whereas in more extended geometries, e.g., IGRT, grid use carries tradeoffs in image quality per unit dose. This work assesses the tradeoffs in dose and image quality for grids applied in the context of low-dose CBCT on a mobile C-arm for image-guided surgery. Methods: Studies were performed on a mobile C-arm equipped with a flat-panel detector for high-quality CBCT. Antiscatter grids of grid ratio (GR) 6:1-12:1, 40 lp/cm, were tested in ''body'' surgery, i.e., spine, using protocols for bone and soft-tissue visibility in the thoracic and abdominal spine. Studies focused on grid orientation, CT number accuracy, image noise, and contrast-to-noise ratio (CNR) in quantitative phantoms at constant dose. Results: There was no effect of grid orientation on possible gridline artifacts, given accurate angle-dependent gain calibration. Incorrect calibration was found to result in gridline shadows in the projection data that imparted high-frequency artifacts in 3D reconstructions. Increasing GR reduced errors in CT number from 31%, thorax, and 37%, abdomen, for gridless operation to 2% and 10%, respectively, with a 12:1 grid, while image noise increased by up to 70%. The CNR of high-contrast objects was largely unaffected by grids, but low-contrast soft-tissues suffered reduction in CNR, 2%-65%, across the investigated GR at constant dose. Conclusions: While grids improved CT number accuracy, soft-tissue CNR was reduced due to attenuation of primary radiation. CNR could be restored by increasing dose by factors of {approx}1.6-2.5 depending on GR, e.g., increase from 4.6 mGy for the thorax and 12.5 mGy for the abdomen without antiscatter grids to approximately 12 mGy and 30 mGy, respectively, with a high

  17. Retrospektive Analyse von Zufallsbefunden, die bei Patienten mit kutanem malignen Malignom durch (18) F-Fluordeoxyglucose-PET/CT erhoben wurden.

    Science.gov (United States)

    Conrad, Franziska; Winkens, Thomas; Kaatz, Martin; Goetze, Steven; Freesmeyer, Martin

    2016-08-01

    Bei der (18) F-Fluordeoxyglucose-Positronenemissionstomographie/Computertomographie (FDG-PET/CT) ergeben sich häufig Zufallsbefunde. In der vorliegenden Studie konzentrierten wir uns auf mittels FDG-PET/CT erhaltene Zufallsbefunde bei Patienten mit kutanem Melanom und überprüften deren Relevanz hinsichtlich weiterer diagnostischer Maßnahmen und Interventionen. Die Krankenakten von 181 konsekutiven Melanom-Patienten wurden retrospektiv ausgewertet, um das Management von Zufallsbefunden zu dokumentieren. Der Schwerpunkt lag dabei auf den histologischen Befunden. Bei 33 von 181 (18 %) Patienten lagen 39 relevante Zufallsbefunde vor, und zwar im Kolorektalbereich (n = 15 Patienten), in der Schilddrüse (n = 8), der Prostata (n = 2), dem Bewegungsapparat (n = 2), in Lymphknoten (n = 2), der Parotis (n = 1), den Mandeln (n = 1), den Nieren (n = 1) und der Gallenblase (n = 1). Bei 25 Patienten schlossen sich weitere diagnostische Verfahren an, wobei in 21 Fällen ein klinisches Korrelat nachgewiesen wurde. Bei 16 von 21 Patienten ergab sich eine Neoplasie, darunter fünf maligne Läsionen (vier Kolonkarzinome und ein Prostatakarzinom). Die Malignome wurden frühzeitig diagnostiziert und in der Mehrzahl der Fälle erfolgreich entfernt. Der Einsatz der FDG-PET/CT als Routine-Diagnostik wird in den Leitlinien empfohlen und ist indiziert bei malignem Melanom ab Stadium IIC. In dieser Studie wurden auf effektive Weise ansonsten nicht erkannte Krebserkrankungen, insbesondere Kolonkarzinome, detektiert. In den meisten Fällen war eine frühe Intervention möglich. Zufallsbefunde durch FDG-PET/CT sollten, unter Berücksichtigung des Zustands und der Wünsche des Patienten, mit den geeigneten diagnostischen Maßnahmen abgeklärt werden. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  18. An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available We have developed an algorithm for the rigid-body registration of a CT volume to a set of C-arm images. The algorithm uses a gradient-based iterative minimization of a least-squares measure of dissimilarity between the C-arm images and projections of the CT volume. To compute projections, we use a novel method for fast integration of the volume along rays. To improve robustness and speed, we take advantage of a coarse-to-fine processing of the volume/image pyramids. To compute the projections of the volume, the gradient of the dissimilarity measure, and the multiresolution data pyramids, we use a continuous image/volume model based on cubic B-splines, which ensures a high interpolation accuracy and a gradient of the dissimilarity measure that is well defined everywhere. We show the performance of our algorithm on a human spine phantom, where the true alignment is determined using a set of fiducial markers.

  19. Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Schaefer, Patrik; Lehnert, Thomas; Mbalisike, Emmanuel; Hammerstingl, Renate; Eichler, Katrin; Zangos, Stephan; Nour-Eldin, Nour-Eldin A.; Ackermann, Hanns; Naguib, Nagy N.N.

    2016-01-01

    To evaluate feasibility of measuring parenchymal blood volume (PBV) of malignant hepatic tumours using C-arm CT, test the changes in PBV following repeated transarterial chemoembolization (TACE) and correlate these changes with the change in tumour size in MRI. 111 patients with liver malignancy were included. Patients underwent MRI and TACE in a 4- to 6-week interval. During intervention C-arm CT was performed. Images were post-processed to generate PBV maps. Blood volume data in C-arm CT and change in size in MRI were evaluated. The correlation between PBV and size was tested using Spearman rank test. Pre-interventional PBV maps showed a mean blood volume of 84.5 ml/1000 ml ± 62.0, follow-up PBV maps after multiple TACE demonstrated 61.1 ml/1000 ml ± 57.5. The change in PBV was statistically significant (p = 0.02). Patients with initial tumour blood volume >100 ml/1000 ml dropped 7.1 % in size and 47.2 % in blood volume; 50-100 ml/1000 ml dropped 4.6 % in size and 25.7 % in blood volume; and <50 ml/1000 ml decreased 2.8 % in size and increased 82.2 % in blood volume. PBV measurement of malignant liver tumours using C-arm CT is feasible. Following TACE PBV decreased significantly. Patients with low initial PBV show low local response rates and further increase in blood volume, whereas high initial tumour PBV showed better response to TACE. (orig.)

  20. Importance of SPECT/CT for knee and hip joint prostheses; Stellenwert der SPECT/CT bei Knie- und Hueftgelenkprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Steurer-Dober, I.; Huellner, M.W.; Veit-Haibach, P.; Allgayer, B. [Luzerner Kantonsspital (Switzerland). Institut fuer Nuklearmedizin und Roentgendiagnostik

    2012-07-15

    Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal. (orig.) [German] Komplikationen wie Lockerung und Infekt stellen ein haeufiges Problem nach Hueft- und Kniegelenkprothesen dar. Wenn die konventionelle Roentgenaufnahme nicht zum Ziel fuehrt, ist die klassische konventionelle Skelettszintigraphie die am haeufigsten verwendete ''Second-line''-Bildgebung. Die ''single photon emission computed tomography''/CT (SPECT/CT) bietet metabolische und morphologische Informationen bzgl. Prothesenkomplikationen in einem Untersuchungsgang und ist zunehmend in groesseren Kliniken verfuegbar. Die SPECT/CT ist eine viel versprechende Methode und wird im klinischen Alltag bei der Evaluation von Gelenkprothesen zunehmend eingesetzt. Es sind noch mehr prospektive Studien noetig, um die Leistungsfaehigkeit und den Zusatznutzen gegenueber der klassischen Szintigraphie zu evaluieren. In unserer Klinik wird die Knochenszintigraphie bei der Abklaerung von Prothesenkomplikationen zumeist mit einer SPECT/CT kombiniert und liefert regelmaessig wichtige Zusatzinformationen. Die SPECT/CT entwickelt sich zunehmend zum Standard

  1. CT-guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver malignancies; CT-gesteuerte Brachytherapie. Eine neue perkutane Technik zur interstitiellen Ablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J.; Wust, P.; Stohlmann, A.; Beck, A.; Cho, C.H.; Pech, M.; Wieners, G.; Spors, B.; Werk, M.; Rosner, C.; Haenninen, E.L.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany)

    2004-05-01

    Purpose: to assess safety and efficacy of CT-guided brachytherapy of liver malignancies. Patients and methods: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a {sup 192}Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size {>=} 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. Results: the mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. Conclusion: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization. (orig.) [German] Ziel: Analyse der Sicherheit und Effektivitaet CT-gesteuerter Brachytherapie zur Ablation von Lebermalignomen. Patienten und Methodik: 21 Patienten mit 21 Lebermalignomen (19 Metastasen, zwei primaere Lebermalignome) wurden mit perkutaner, CT-gesteuerter interstitieller Brachytherapie mit {sup 192}Ir behandelt. Alle Patienten wiesen Umstaende auf, die eine bildgefuehrte thermische Ablation mit Radiofrequenz oder laserinduzierter Thermotherapie (LITT) einschraenkten

  2. Tumor-like diseases of the knee joint; Tumoraehnliche Erkrankungen im Kniegelenk

    Energy Technology Data Exchange (ETDEWEB)

    Freyschmidt, J. [Klinikum Bremen-Mitte, Beratungsstelle und Referenzzentrum fuer Osteoradiologie, Bremen (Germany)

    2012-11-15

    Radiological diagnostics of tumor-like lesions of the knee joint. Magnetic resonance imaging (MRI), computed tomography (CT) and X-ray imaging. Up to now there have been no studies regarding sensitivity and specificity of the various diagnostic tools (MRI, CT, X-ray) for the visualization of soft tissue tumors of the knee. The method of first choice for detecting soft tissue tumors and tumor-like lesions in the knee joint is MRI. (orig.) [German] Radiologische Diagnostik tumoraehnlicher Laesionen im Kniegelenk. Eingesetzte Verfahren sind die MRT, CT und Projektionsradiographie. Da es sich um Weichteiltumoren handelt, ist die MRT bei der Diagnostik dominierend. Sensitivitaet und Spezifitaet sind unserer Kenntnis nach bisher nicht untersucht worden. In manchen Faellen werden jedoch noch zusaetzliche Roentgen- oder CT-Bilder benoetigt. Bei Verdacht auf einen Tumor im Kniegelenk wird als erste Untersuchung eine MRT empfohlen. (orig.)

  3. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  4. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    151 konsekutive Patienten mit Verdacht auf Pankreastumor untersucht. Hydro-CT-Technik: Patientenlagerung in 30 RAO, Darmparalyse durch 40 mg Buscopan, Magen- und Duodenaldistension mittels 1,5 l Wasser oral, individualisierte Boluskinetik Spiral-CT mit 3 mm Inkrement, 6 mm Tischvorschub und 3 mm Rekonstruktion, 130 ml nichtionisches KM (5 ml/s). Folgende Punkte wurden festgehalten und bewertet: 1. Tumordetektion ja/nein; 2. Differenzierung eines festgestellten Tumors in maligne oder benigne an Hand festgelegter Kriterien; 3. computertomographische Differentialdiagnostik der Tumoren; 4. Beurteilung der Resektabilitaet. Bei positivem Tumornachweis wurde als Goldstandard die intraoperative und histologische Bewertung und bei negativem Tumornachweis eine 6 monatige tumorfreie Nachsorgeperiode festgelegt. Die Praevalenz einer Raumforderung des Pankreas betrug etwa 38% in der Gesamtgruppe. Dabei erreichte die Hydro-CT eine Gesamtgenauigkeit in der Tumordetektion von 97,4% bei einer Sensitivitaet von 100% und einer Spezifitaet von 95,9%. Bei der Differenzierung eines malignen versus eines benignen Tumors ergab sich eine Gesamtgenauigkeit von 89,7% bei einer Sensitivitaet von 92,5% und einer Spezifitaet von 83,3%. 58 Patienten wurden operiert. Die Gesamtgenauigkeit der Resektabilitaetsbeurteilung erreichte 95% bei einer Sensitivitaet von 90,5% und einer Spezifitaet von 100%. (orig./MG)

  5. Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions

    Science.gov (United States)

    Buerger, C.; Lorenz, C.; Babic, D.; Hoppenbrouwers, J.; Homan, R.; Nachabe, R.; Racadio, J. M.; Grass, M.

    2017-03-01

    Spinal fusion is a common procedure to stabilize the spinal column by fixating parts of the spine. In such procedures, metal screws are inserted through the patients back into a vertebra, and the screws of adjacent vertebrae are connected by metal rods to generate a fixed bridge. In these procedures, 3D image guidance for intervention planning and outcome control is required. Here, for anatomical guidance, an automated approach for vertebra segmentation from C-arm CT images of the spine is introduced and evaluated. As a prerequisite, 3D C-arm CT images are acquired covering the vertebrae of interest. An automatic model-based segmentation approach is applied to delineate the outline of the vertebrae of interest. The segmentation approach is based on 24 partial models of the cervical, thoracic and lumbar vertebrae which aggregate information about (i) the basic shape itself, (ii) trained features for image based adaptation, and (iii) potential shape variations. Since the volume data sets generated by the C-arm system are limited to a certain region of the spine the target vertebra and hence initial model position is assigned interactively. The approach was trained and tested on 21 human cadaver scans. A 3-fold cross validation to ground truth annotations yields overall mean segmentation errors of 0.5 mm for T1 to 1.1 mm for C6. The results are promising and show potential to support the clinician in pedicle screw path and rod planning to allow accurate and reproducible insertions.

  6. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  7. Interventional heart wall motion analysis with cardiac C-arm CT systems

    International Nuclear Information System (INIS)

    Müller, Kerstin; Maier, Andreas K; Schwemmer, Chris; Hornegger, Joachim; Zheng, Yefeng; Wang, Yang; Lauritsch, Günter; Rohkohl, Christopher; Fahrig, Rebecca

    2014-01-01

    Today, quantitative analysis of three-dimensional (3D) dynamics of the left ventricle (LV) cannot be performed directly in the catheter lab using a current angiographic C-arm system, which is the workhorse imaging modality for cardiac interventions. Therefore, myocardial wall analysis is completely based on the 2D angiographic images or pre-interventional 3D/4D imaging. In this paper, we present a complete framework to study the ventricular wall motion in 4D (3D+t) directly in the catheter lab. From the acquired 2D projection images, a dynamic 3D surface model of the LV is generated, which is then used to detect ventricular dyssynchrony. Different quantitative features to evaluate LV dynamics known from other modalities (ultrasound, magnetic resonance imaging) are transferred to the C-arm CT data. We use the ejection fraction, the systolic dyssynchrony index a 3D fractional shortening and the phase to maximal contraction (ϕ i, max ) to determine an indicator of LV dyssynchrony and to discriminate regionally pathological from normal myocardium. The proposed analysis tool was evaluated on simulated phantom LV data with and without pathological wall dysfunctions. The LV data used is publicly available online at https://conrad.stanford.edu/data/heart. In addition, the presented framework was tested on eight clinical patient data sets. The first clinical results demonstrate promising performance of the proposed analysis tool and encourage the application of the presented framework to a larger study in clinical practice. (paper)

  8. Scatter correction using a primary modulator on a clinical angiography C-arm CT system.

    Science.gov (United States)

    Bier, Bastian; Berger, Martin; Maier, Andreas; Kachelrieß, Marc; Ritschl, Ludwig; Müller, Kerstin; Choi, Jang-Hwan; Fahrig, Rebecca

    2017-09-01

    Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is inserted between the X-ray source and the object. This modulation enables estimation of the scatter in the projection domain by optimizing an objective function with respect to the scatter estimate. Up to now the approach has not been implemented on a clinical angiography C-arm CT system. In our work, the iPMSE method is transferred to a clinical C-arm CBCT. Additional processing steps are added in order to compensate for the C-arm scanner motion and the automatic X-ray tube current modulation. These challenges were overcome by establishing a reference modulator database and a block-matching algorithm. Experiments with phantom and experimental in vivo data were performed to evaluate the method. We show that scatter correction using primary modulation is possible on a clinical C-arm CBCT. Scatter artifacts in the reconstructions are reduced with the newly extended method. Compared to a scan with a narrow collimation, our approach showed superior results with an improvement of the contrast and the contrast-to-noise ratio for the phantom experiments. In vivo data are evaluated by comparing the results with a scan with a narrow collimation and with a constant scatter correction approach. Scatter correction using primary modulation is possible on a clinical CBCT by compensating for the scanner motion and the tube current modulation. Scatter artifacts could be reduced in the reconstructions of phantom scans and in experimental in vivo data. © 2017 American Association of Physicists in Medicine.

  9. Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model.

    Science.gov (United States)

    Veulemans, Verena; Mollus, Sabine; Saalbach, Axel; Pietsch, Max; Hellhammer, Katharina; Zeus, Tobias; Westenfeld, Ralf; Weese, Jürgen; Kelm, Malte; Balzer, Jan

    2016-10-26

    To investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR). Rotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT data set was segmented using a 3D heart model. From that the line of perpendicularity curve was obtained that generates a perpendicular view of the aortic annulus according to the right-cusp rule. To evaluate the accuracy of a model-based overlay we compared model- and expert-derived aortic root diameters. For all 57 patients in the RCT cohort diameter measurements were obtained from two independent operators and were compared to the model-based measurements. The inter-observer variability was measured to be in the range of 0°-12.96° of angular C-arm displacement for two independent operators. The model-to-operator agreement was 0°-13.82°. The model-based and expert measurements of aortic root diameters evaluated at the aortic annulus ( r = 0.79, P optimal C-arm configuration, potentially simplifying current clinical workflows before and during TAVR.

  10. Needle and catheter navigation using electromagnetic tracking for computer-assisted C-arm CT interventions

    Science.gov (United States)

    Nagel, Markus; Hoheisel, Martin; Petzold, Ralf; Kalender, Willi A.; Krause, Ulrich H. W.

    2007-03-01

    Integrated solutions for navigation systems with CT, MR or US systems become more and more popular for medical products. Such solutions improve the medical workflow, reduce hardware, space and costs requirements. The purpose of our project was to develop a new electromagnetic navigation system for interventional radiology which is integrated into C-arm CT systems. The application is focused on minimally invasive percutaneous interventions performed under local anaesthesia. Together with a vacuum-based patient immobilization device and newly developed navigation tools (needles, panels) we developed a safe and fully automatic navigation system. The radiologist can directly start with navigated interventions after loading images without any prior user interaction. The complete system is adapted to the requirements of the radiologist and to the clinical workflow. For evaluation of the navigation system we performed different phantom studies and achieved an average accuracy of better than 2.0 mm.

  11. CT of abdominal tumor

    International Nuclear Information System (INIS)

    Endo, Satoshi; Yamada, Kenji; Ito, Masatoshi; Ito, Hisao; Yamaura, Harutsugu

    1981-01-01

    CT findings in 33 patients who had an abdominal tumor were evaluated. CT revealed a tumor in 31 cases. The organ from which the tumor originated was correctly diagnosed in 18 patients. Whether the tumor was solid or cystic was correctly predicted in 28 patients. The diagnosis malignant or benign nature of tumor was correct, incorrect and impossible, in 23, 3, and five patiens, respectively. (Kondo, M.)

  12. Osteogenic tumors of bone; Osteogene Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Jobke, B. [Deutsches Krebsforschungszentrum (DKFZ), Abtl. Radiologie, Heidelberg (Germany); Werner, M. [MVZ des HELIOS Klinikum Emil von Behring, Orthopaedische Pathologie - Referenzzentrum, Institut fuer Gewebediagnostik Berlin, Berlin (Germany)

    2016-06-15

    Osteogenic tumors include malignant and benign tumors that produce tumor osteoid and/or bone tissue. Osteosarcoma is the most common malignant bone tumor, especially in children and young adults. The entities with their characteristic morphological features are described to enable the reader to come to a diagnosis and differential diagnosis on the basis of patient age, history and predominant location of the tumor. For this review we selectively used mainly large published patient cohorts. Our own and externally published data on widely accepted tumor criteria were also compared. Detection is the initial diagnostic step for an osseous lesion, and is determined by the sensitivity of the method applied. Plain X-ray films in two planes and CT are the basics in the radiological toolkit for osteogenic tumors. For evaluation of local tumor extension and biopsy planning MRI or scintigraphy should be combined. MRI as a stand-alone diagnostic tool is insufficient. For malignant bone tumors staging should be performed, applying a variable combination of thoracic CT, MRI, scintigraphy, and positron emission tomography (PET). Osteosarcoma, along with Ewing sarcoma and chondrosarcoma, are the most common malignant bone tumors; all sub-entities are significantly rarer. Among benign bone tumors, osteoid osteomas have the highest incidence, presenting with typical pain, location, and age predilection. Diagnostics and treatment of malignant bone tumors should preferably be performed in specialized centers because of significant therapeutic implications for patients. In uncertain cases, a second opinion should always be obtained. (orig.) [German] Osteogene Tumoren umfassen maligne und benigne Tumoren, die eine tumoreigene Produktion von Osteoid und/oder Knochengewebe aufweisen. Das Osteosarkom ist der haeufigste maligne Knochentumor v. a. bei Kindern und jungen Erwachsenen. Es werden die Entitaeten mit ihren morphologischen Charakteristika beschrieben, um anhand wichtiger

  13. Brain tumor and CT, 1. Relationship between the consistency of a brain tumor and the CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, N.; Katada, K.; Shinomiya, Y.; Sano, H.; Kanno, T. (Fujita Gakuen Univ., School of Medicine, Toyoake, Aichi (Japan))

    1981-08-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively. Twenty-seven cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor.

  14. Dental-CT and pathologic conditions of the jaw; Dental-CT bei pathologischen Veraenderungen im Bereich des Kiefers

    Energy Technology Data Exchange (ETDEWEB)

    Abrahams, J.J. [Yale Univ., New Haven, CT (United States). Dept. of Diagnostic Radiology

    1999-12-01

    CT with multiplanar reconstruction of the jaws (DentaScan{sup TM}) is the method of choice for the radiographic assessment of the mandible and maxilla. It is instrumental in delineating the relationship between bony lesions and the adjacent anatomy. Therefore, this technique allows precise evaluation of the intricate details of the oral cavity. Using it, distinct characterization of pathology including infectious, metabolic, congenital and neoplastic lesions can be obtained. (orig.) [German] Die CT mit multiplanarer Rekonstruktion des Kiefers (Dental-CT/Denta-Scan{sup TM}) ist die Methode der Wahl zur radiologischen Untersuchung der Mandibula und Maxilla. Sie ist insbesondere bei der Abgrenzung knoecherner Laesionen von benachbarten anatomischen Strukturen hilfreich. Daher erlaubt diese Technik eine praezise Evaluation der komplizierten Details der Mundhoehle. Durch die Verwendung dieser Technik wird eine genaue Charakterisierung von Pathologien, unter Einschluss infektioeser, metabolischer, kongenitaler und neoplastischer Laesionen ermoeglicht. (orig.)

  15. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  16. Lipiodol injections for optimization of target volume delineation in a patient with a second tumor of the oropharynx. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Haderlein, Marlen; Merten, Ricarda; Stojanovic, Andrea; Speer, Stefan; Fietkau, Rainer; Ott, Oliver J. [University Hospitals of Erlangen, Department of Radiation Oncology, Erlangen (Germany); Scherl, Claudia [University Hospitals of Erlangen, Department of Otorhinolaryngology, Erlangen (Germany)

    2015-08-15

    Lipiodol injections were administered in the head and neck area to improve gross tumor volume (GTV) definition for small-volume re-irradiation of a 63-year-old previously irradiated patient with a second tumor of the oropharynx in the posterior wall with longitudinal ligament infiltration (cT4cN0cM0). The patient had dialysis-depending renal failure. On diagnostic computed tomography (CT), which was performed with intravenous contrast agent, the tumor in the oropharynx was not detectable. Because of dialysis-depending renal failure comorbidity, no contrast agent was applied in the planning CT and in the diagnostic magnetic resonance imaging (MRI) study. In each cross-sectional imaging study performed, the GTV, especially in craniocaudal extensions, was not safely delineable. Therefore, craniocaudal tumor margins were pharyngoscopically marked with Lipiodol injections, an iodine-containing contrast agent. In a second planning CT, the GTV could be defined with the help of the Lipiodol marks and small-volume re-irradiation was performed. No Lipiodol-associated side effects occurred in the patient. In the present case, the use of Lipiodol injections at the tumor margins facilitated the definition of the GTV. (orig.) [German] Anwendung von Lipiodolinjektionen im Kopf-Hals-Bereich zur Verbesserung der GTV-Definition bei einer kleinvolumigen Re-Bestrahlung eines 63-jaehrigen, vorbestrahlten Patienten mit einem Zweitmalignom im Oropharynx mit Infiltration des hinteren Laengsbandes (cT4cN0cM0). Nebenbefundlich bestand bei dem Patienten eine dialysepflichtige Niereninsuffizienz. Im initialen diagnostischen Kontrastmittel-CT der Hals und Thoraxregion war der Tumor nicht abgrenzbar, so dass das Bestrahlungsplanungs-CT in Anbetracht des diagnostischen CTs und der bekannten Niereninsuffizienz ohne intravenoeses Kontrastmittel durchgefuehrt wurde. Das diagnostische MRT (vgl. Abb. 1) wurde ebenfalls ohne intravenoeses Kontrastmittel durchgefuehrt wurden. In allen durchgefuehrten

  17. Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chin-Chen; Lee, Bo-Ching; Chang, Yeun-Chung; Liu, Kao-Lang [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Medical Imaging, Taipei (China); Wu, Vin-Cent [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Internal Medicine, Taipei (China); Huang, Kuo-How [National Taiwan University Hospital and National Taiwan University College of Medicine, Department of Urology, Taipei (China); Collaboration: on behalf of the TAIPAI Study Group

    2017-12-15

    To compare the performance of on-site quick cortisol assay (QCA) and C-arm computed tomography (CT) assistance on adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. The institutional review board at our hospital approved this retrospective study, which included 178 consecutive patients with primary aldosteronism. During AVS, we used C-arm CT to confirm right adrenal cannulation between May 2012 and June 2015 (n = 100) and QCA for bilateral adrenal cannulation between July 2015 and September 2016 (n = 78). Successful AVS required a selectivity index (cortisol{sub adrenal} {sub vein}/cortisol{sub peripheral}) of ≥ 2.0 bilaterally. The overall success rate of C-arm CT-assisted AVS was 87%, which increased to 97.4% under QCA (P =.013). The procedure time (C-arm CT, 49.5 ± 21.3 min; QCA, 37.5 ± 15.6 min; P <.001) and radiation dose (C-arm CT, 673.9 ± 613.8 mGy; QCA, 346.4 ± 387.8 mGy; P <.001) were also improved. The resampling rate was 16% and 21.8% for C-arm CT and QCA, respectively. The initial success rate of the performing radiologist remained stable during the study period (C-arm CT 75%; QCA, 82.1%, P =.259). QCA might be superior to C-arm CT for improving the performance of AVS. (orig.)

  18. Tumors of the posterior cranial fossa; Tumoren der hinteren Schaedelgrube

    Energy Technology Data Exchange (ETDEWEB)

    Papanagiotou, P.; Politi, M. [Klinikum Bremen-Mitte/Bremen-Ost, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Bremen (Germany)

    2016-11-15

    Various types of brain tumor can occur in the region of the posterior fossa. Brain metastases in adults are the most common malignancies at this localization. Ependymomas, medulloblastomas and pilocytic astrocytomas occur mostly in children and only rarely in adults. Other tumors that occur in the posterior fossa are meningiomas, schwannomas, hemangioblastomas, brain stem gliomas and epidermoid tumors. Due to the fact that the various tumors of the posterior fossa have different treatment approaches and prognoses, an accurate and specific diagnosis is mandatory. This review discusses the imaging aspects by computed tomography (CT) and magnetic resonance imaging (MRI) of the most frequent tumors of the posterior fossa. (orig.) [German] Im Bereich der hinteren Schaedelgrube treten verschiedene Typen von Hirntumoren auf, wobei Hirnmetastasen bei Erwachsenen die haeufigsten Malignitaeten in dieser Region darstellen. Ependymome, Medulloblastome und pilozytische Astrozytome kommen meistens bei Kindern und nur selten bei Erwachsenen vor. Weitere Tumoren der hinteren Schaedelgrube sind Meningeome, Schwannome, Haemangioblastome, Hirnstammgliome und Epidermoide. Da die verschiedenen Tumoren der hinteren Schaedelgrube unterschiedliche Behandlungsansaetze sowie Prognosen haben, ist eine genaue und spezifische Diagnose obligatorisch. Dieser Review diskutiert die bildgebenden CT- und MRT-Aspekte der haeufigsten Tumoren der hinteren Schaedelgrube. (orig.)

  19. C-arm CT-guided renal arterial embolisation followed by radiofrequency ablation for treatment of patients with unresectable renal cell carcinoma

    International Nuclear Information System (INIS)

    Duan, X.-H.; Li, Y.-S.; Han, X.-W.; Wang, Y.-L.; Jiao, D.-C.; Li, T.-F.; Chen, P.-F.; Fang, Y.

    2016-01-01

    Aim: To explore the value of using flat detector (FD) equipped angiographic C-arm CT (CACT) systems in treating unresectable renal cell carcinoma (RCC) by selective renal arterial embolisation (RAE) followed by radiofrequency ablation (RFA) (RAE-RFA). Materials and methods: A total of 28 patients who were not candidates for surgery were enrolled. The average size of tumours was 6.7±2.2 cm (range 4.1–9.6 cm). Twenty-eight tumours were treated with CACT-guided RFA, 5–7 days after CACT-guided RAE. Results: CACT-guided RAE-RFA was technically successful in all patients. Tumour enhancement disappeared after a single RAE-RFA session in 20 patients, after two RAE-RFA sessions in four patients and after three RAE-RFA sessions in the other four patients. One patient died of lung metastasis and haematuria 13 months after RAE-RFA, and another patient died of pulmonary heart disease 23 months after repeat RAE-RFA. In the 26 living patients, tumours remained controlled during a mean follow-up period of 27 months and showed significant reduction in tumour size (6.7±2.2 cm to 3.9±1.7 cm, p<0.01). There were no significant changes in creatinine levels or urea nitrogen concentrations before and after the last RAE-RFA (p>0.05). There were no serious complications during and after the procedure. Conclusion: CACT-guided RAE followed by RFA appears to be a safe and effective technique for treating patients with inoperable RCC. - Highlights: • Selective RAE combined with RFA (RAE-RFA) is used to treat unresectable RCC. • We assessed the C-arm CT (CACT) based needle guidance system to perform RAE-RFA. • Tumors were controlled and reduced in size following CACT-guided RAE-RFA. • No significant changes in renal function occurred post-CACT-guided RAE-RFA. • CACT-guided RAE-RFA for treating RCC appears to be a safe and effective technique.

  20. CT-guided interventions in children; Computertomografisch gesteuerte Interventionen bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2007-06-15

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  1. Magnetic resonance spectroscopy of brain tumors; MR-Spektroskopie bei Hirntumoren

    Energy Technology Data Exchange (ETDEWEB)

    Ditter, P.; Hattingen, E. [Universitaetsklinikum Bonn, FE Neuroradiologie, Radiologische Klinik, Bonn (Germany)

    2017-06-15

    Conventional magnetic resonance imaging (MRI) under consideration of clinical information enables the correct diagnosis and therapy for the majority of cerebral space-occupying lesions. Some important differential diagnoses, e. g. low vs. high-grade tumors, require additional MRI methods. This article critically discusses the importance of magnetic resonance spectroscopy ({sup 1}H-MRS) in brain tumors. The concentration of normal and pathological brain metabolites can be non-invasively measured by {sup 1}H-MRS. It is based on the principle that chemical proton compounds of certain brain metabolites focally attenuate the external magnetic field and change the proton resonance frequency according to typical patterns. In addition, parameter maps of MRS imaging (MRSI) can show the tumor heterogeneity as well as changes in the surrounding brain tissue. In this context, the patterns of N-acetylaspartate, total choline (tCho) and creatine are relatively robust, whereas the patterns of other metabolites, such as myoinositol, glutamate, lactate or lipids greatly depend on the external field strength and echo time. The signal intensity of tCho in vital tumor tissue increases with the WHO grade of the brain tumor, i.e. increases with the level of malignancy. The use of MRSI facilitates the WHO grading of gliomas by determining target points in biopsies. Different distribution patterns and specific metabolite signals enable a better differentiation between abscesses, metastases, central nervous system (CNS) lymphomas and gliomas. The use of {sup 1}H-MRS provides valuable information on the differential diagnosis and graduation of brain tumors; however, so far artefacts, signal strength, parameter selection and a lack of standardization impede the establishment of {sup 1}H-MRS for use in clinical routine diagnostics. (orig.) [German] Die konventionelle MRT ermoeglicht unter Beruecksichtigung klinischer Information bei einem Grossteil zerebraler Raumforderungen die richtige

  2. Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients.

    Science.gov (United States)

    Chang, Chin-Chen; Lee, Bo-Ching; Chang, Yeun-Chung; Wu, Vin-Cent; Huang, Kuo-How; Liu, Kao-Lang

    2017-12-01

    To compare the performance of on-site quick cortisol assay (QCA) and C-arm computed tomography (CT) assistance on adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. The institutional review board at our hospital approved this retrospective study, which included 178 consecutive patients with primary aldosteronism. During AVS, we used C-arm CT to confirm right adrenal cannulation between May 2012 and June 2015 (n = 100) and QCA for bilateral adrenal cannulation between July 2015 and September 2016 (n = 78). Successful AVS required a selectivity index (cortisol adrenal vein /cortisol peripheral ) of ≥ 2.0 bilaterally. The overall success rate of C-arm CT-assisted AVS was 87%, which increased to 97.4% under QCA (P = .013). The procedure time (C-arm CT, 49.5 ± 21.3 min; QCA, 37.5 ± 15.6 min; P AVS. • Adrenal venous sampling (AVS) is a technically challenging procedure. • C-arm CT and quick cortisol assay (QCA) are efficient for assisting AVS. • QCA might outperform C-arm CT in enhancing AVS performance.

  3. Transarterial chemoperfusion with gemcitabine and mitomycin C in pancreatic carcinoma: Results in locally recurrent tumors and advanced tumor stages; Transarterielle Chemoperfusion mit Gemcitabine und Mitomycin C bei Pankreaskarzinom: Ergebnisse bei Rezidivtumoren und fortgeschrittenen Tumorstadien

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Zangos, S.; Heller, M.; Hammerstingl, R.M.; Bauer, R.W. [Inst. fuer Diagnostische und Interventionelle Radiologie, J. W. Goethe-Univ. Frankfurt (Germany); Boecher, E. [Klinik Paradise, Medizinische Klinik, Soest (Germany); Jacob, U. [Leonardisklinik, Onkologische Fachklinik, Bad Heilbrunn (Germany)

    2007-11-15

    Purpose: The purpose of this study was to evaluate local transarterial chemoperfusion (TACP) in locally recurrent pancreatic carcinoma and advanced tumor stages which did not respond to prior systemic chemotherapy. The tumor response, survival, and pain response were retrospectively analyzed. Materials and method: Forty outpatients (median age 62 years, range 36 - 79) were treated with a minimum of 3 (mean 6, range 3 - 12) applications per patient in four-week intervals. Twenty-eight patients were in advanced tumor stages, and 12 patients had locally recurrent tumors. Gemcitabine (1,000 mg/m{sup 2}) and mitomycin C (8.5 mg/m{sup 2}) were administered within 1 hour through a celiac trunk catheter. The tumor response (diameter, volume) was measured using MRI or CT and classified according to RECIST. The pain response was defined as a reduction of pain intensity of more than 50% on a visual analog scale, or a reduction of more than 50% in analgesics consumption, or a switch to a less potent analgesic agent. Results: The treatment was tolerated well by all patients. No clinically relevant problems or grade III or IV toxicity according to CTC (Common Toxicity Criteria) were observed. Tumor-related pain was relieved in 20/32 (62.5%) cases. Radiologically, 'complete response' was found in 3/40 (7.5%), 'partial response' in 9/40 (22.5%), 'stable disease' in 16/40 (40%), and 'progressive disease' in 12/40 (30%) of the patients. The median survival period since initial diagnosis and first TACP was 16.4 months and 8.1 months, respectively. Locally recurrent tumors showed better, but still not significant results regarding tumor response (41.7% vs. 25%) as well as survival (14.4 vs. 7 months) compared to advanced tumor stages. Responders (CR + PR) showed a significant survival advantage compared to patients with tumor progression (13.0 vs. 6.0 months; p = 0.013). (orig.)

  4. Arteries of the falciform ligament on C-arm CT hepatic arteriography: The hepatic falciform artery and the Sappey's superior artery

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Saebeom; Chung, Jin Wook; Lee, Jae Hwan; Cho, SooBeum; Kim, Minuk; Lee, Myungsu; Kim, Hyo-Cheol; Jae, Hwan Jun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Zhou, Chun Gao [First Affiliated Hospital of Nanjing Medical University, Department of Interventional Radiology, Nanjing, Jangsu (China)

    2017-04-15

    To investigate the prevalence, anatomy and distribution of the hepatic falciform artery (HFA) and Sappey's superior artery (SSA) using C-arm CT hepatic arteriography (C-arm CTHA). From January 2011 to December 2012, 220 patients who underwent C-arm CTHA during initial transarterial treatment for hepatocellular carcinoma were included in this retrospective study. The HFAs and SSAs prevalence and origin were evaluated using axial images of C-arm CTHA. A 5-point scale for HFAs and a 4-point scale for SSAs were used to designate the radiologically conspicuous arteries. The prevalences of the total HFAs and SSAs were 95 % (n=209) and 22 % (n=49), while those of radiologically conspicuous HFAs and SSAs were 62 % (n=137) and 10 % (n=22), respectively. Thirty HFAs (22 % of radiologically conspicuous HFAs and 14 % of the total study population) were distributed in the subcutaneous layer of the anterior abdominal wall, while the majority of SSAs ran through the superior part of the falciform ligament in the left-anterior direction and anastomosed with left inferior phrenic artery. Our study using C-arm CTHA revealed that the prevalence of the HFA is higher than the existing knowledge and proved the existence of the SSA radiologically for the first time. (orig.)

  5. Arteries of the falciform ligament on C-arm CT hepatic arteriography: The hepatic falciform artery and the Sappey's superior artery

    International Nuclear Information System (INIS)

    Hur, Saebeom; Chung, Jin Wook; Lee, Jae Hwan; Cho, SooBeum; Kim, Minuk; Lee, Myungsu; Kim, Hyo-Cheol; Jae, Hwan Jun; Zhou, Chun Gao

    2017-01-01

    To investigate the prevalence, anatomy and distribution of the hepatic falciform artery (HFA) and Sappey's superior artery (SSA) using C-arm CT hepatic arteriography (C-arm CTHA). From January 2011 to December 2012, 220 patients who underwent C-arm CTHA during initial transarterial treatment for hepatocellular carcinoma were included in this retrospective study. The HFAs and SSAs prevalence and origin were evaluated using axial images of C-arm CTHA. A 5-point scale for HFAs and a 4-point scale for SSAs were used to designate the radiologically conspicuous arteries. The prevalences of the total HFAs and SSAs were 95 % (n=209) and 22 % (n=49), while those of radiologically conspicuous HFAs and SSAs were 62 % (n=137) and 10 % (n=22), respectively. Thirty HFAs (22 % of radiologically conspicuous HFAs and 14 % of the total study population) were distributed in the subcutaneous layer of the anterior abdominal wall, while the majority of SSAs ran through the superior part of the falciform ligament in the left-anterior direction and anastomosed with left inferior phrenic artery. Our study using C-arm CTHA revealed that the prevalence of the HFA is higher than the existing knowledge and proved the existence of the SSA radiologically for the first time. (orig.)

  6. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D); Untersuchungen zur Bildqualitaet, Hochkontrastaufloesung und Dosis am Stamm- und Gliedmassenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)

    Energy Technology Data Exchange (ETDEWEB)

    Rock, C.; Kotsianos, D.; Linsenmaier, U. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Klinische Radiologie; Fischer, T. [Klinikum der Universitaet Muenchen, Muenchen (DE). Inst. fuer Klinische Radiologie] (and others)

    2002-02-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [German] Zielsetzung: Evaluierung der 3D-CT-Bildgebung mit einem C-Bogen-basierten dedizierten CT-System (ISO-C-3D, Fa. Siemens) an Extremitaetengelenken und am Stammskelett. Methodik: 27 humane Leichenpraeparate der unteren und oberen Extremitaet sowie des Stammskeletts wurden am ISO-C-3D untersucht und die Bilddaten anhand eines Bildqualitaetsscores von 3 Untersuchern semiquantitativ evaluiert (Score 1: nicht

  7. Gastroenteropancreatic endocrine tumors; Gastroenteropankreatische endokrine Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Schmid-Tannwald, C.; Schmid-Tannwald, C.M.; Reiser, M.F.; Berger, F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2014-10-15

    % aller gastrointestinalen Tumoren ausmacht. Fuer die Lokalisation des Primaertumors als auch fuer das Staging endokriner Tumoren spielen neben der Ultraschalldiagnostik die Computertomographie (CT), die Magnetresonanztomographie (MRT) und die Positronenemissionstomographie-Computertomographie (PET-CT) eine entscheidende Rolle. Neben dem Primaerstaging lassen sich mithilfe der PET-CT mit Somatostatinanaloga auch die Indikation fuer eine Radionuklidtherapie stellen und der Therapieverlauf dokumentieren. Das CT-Enteroklysma erreicht nach der Literatur bei Duenndarmtumoren bis 3 cm eine Sensitivitaet von 84,7 %, eine Spezifitaet von 96,9 %; mit der Magnetresonanzenterographie (MRE) kann ein neuroendokriner Tumor (NET) des Duenndarms in 93,3 % der Faelle lokalisiert werden. Laut Literatur ist die MRT bei der Detektion pankreatischer NET mit einer Sensitivitaet zwischen 74 und 100 % der CT ueberlegen. Die PET-CT ermoeglicht die Detektion sehr kleiner Primaertumoren und gilt als sensitivste Methode zur Lokalisationsdiagnostik. Bei der Detektion von Lebermetastasen ist die MRT der CT und der PET-CT ueberlegen. Aufgabe der bildgebenden Diagnostik ist es, neben der Lokalisation des Primaertumors und dem Staging, Therapien zu planen und ein Therapieansprechen zu dokumentieren. Die Wahl der verschiedenen bildgebenden Verfahren hierfuer ist abhaengig von der Lokalisation des Primaertumors. Da gastroenteropankreatische neuroendokrine Tumoren (GEP-NET) ueberwiegend hypervaskularisiert sind, ist eine biphasische Untersuchungstechnik nach Kontrastmittelgabe in arterieller und venoeser Phase fuer die Abklaerung von Primaertumoren und Metastasen sowohl in der CT wie in der MRT obligat. Fuer das Ganzkoerperstaging kommen vorrangig CT und PET-CT zum Einsatz. (orig.)

  8. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  9. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kyung Cha, Bo [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae, E-mail: sarim@keri.re.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Huh, Young [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  10. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    International Nuclear Information System (INIS)

    Kyung Cha, Bo; Seo, Chang-Woo; Yang, Keedong; Jeon, Seongchae; Huh, Young

    2015-01-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally

  11. Peculiarities in the CT findings of germ cell tumors in various tumor localizations

    International Nuclear Information System (INIS)

    Tazoe, Makoto; Miyagami, Mitsusuke; Tsubokawa, Takashi

    1991-01-01

    The CT findings of 17 germ cell tumors were studied in relation to the locations of the tumor, the pathological diagnoses, and the tumor markers (AFP and HCG). Generally, the CT findings of germ cell tumors depended on the pathological diagnoses more strongly than on the location of the tumors. On plain CT of 7 germ cell tumors in the pineal region, all of them demonstrated heterogeneous findings. Hydrocephalus was seen in 6 cases (86%) and calcification in 6 cases (86%) of the germ cell tumors in the pineal region. Calcification and hydrocephalus that appeared more often than in other regions were characteristic of germ cell tumors of the pineal region. The germ cell tumors in the basal ganglia had a slightly homogenous high density, with small cysts and calcification in most of them on plain CT. On enhanced CT, the tumors were moderately enhanced in all cases located in the basal ganglia. Four cases of germ cell tumors located in the basal ganglia revealed the dilatation of lateral ventricle due to hemispheric atrophy in the tumor side. The germ cell tumors showing an increase in the tumor markers such as AFP and HCG, which were usually malignant germ cell tumors, were strongly enhanced on enhanced CT. (author)

  12. Possibilities for exposure reduction in computed tomography examination of acute chest pain; Moeglichkeiten der Dosisreduktion bei CT-Untersuchungen des akuten Thoraxschmerzes

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H.C. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2012-10-15

    Electrocardiogram-gated (ECG) computed tomography (CT) investigations can be accompanied by high amounts of radiation exposure. This is particularly true for the investigation of patients with unclear and acute chest pain. The common approach in patients with acute chest pain is standard spiral CT of the chest. The chest pain or triple-rule-out CT protocol is a relatively new ECG-gated protocol of the entire chest. This article reviews and discusses different techniques for the CT investigation of patients with acute chest pain. By applying the appropriate scan technique, the radiation exposure for an ECG-gated protocol must not necessarily be higher than a standard chest CT scan Aortic pathologies are far better depicted by ECG-gated scan protocols and depending on the heart rate coronary artery disease can also be detected at the same time. The use of ECG-triggered scans will not support the diagnostics of the pulmonary arteries. However, in unspecific chest pain an ECG-triggered scan protocol can provide information on the differential diagnosis. (orig.) [German] EKG-getriggerte CT-Untersuchungen koennen mit einer relativ hohen Strahlenexposition einhergehen. Dies gilt im besonderen Masse fuer die Untersuchung des gesamten Thorax bei Patienten mit unklarem akutem Thoraxschmerz. Bisher wurden Untersuchungen bei Patienten mit akutem Thoraxschmerz in Spiraltechnik ohne EKG-Triggerung durchgefuehrt. Das ''Chest-pain-'' oder ''Triple-rule-out''-Protokoll ist ein neues EKG-getriggertes Untersuchungsprotokoll des gesamten Thorax. Im vorliegenden Artikel werden verschiedene Techniken zur CT-Untersuchung von Patienten mit akutem Thoraxschmerz vorgestellt und besprochen. Mit der richtigen Untersuchungstechnik muss die Strahlenexposition fuer ein EKG-getriggertes Untersuchungsprotokoll nicht hoeher sein als eine Standarduntersuchung ohne EKG. Mit einem EKG-getriggerten Untersuchungsprotokoll laesst sich die Aorta in Hinblick auf

  13. Is There an Additional Value of 11C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

    International Nuclear Information System (INIS)

    Van den Bergh, Laura; Koole, Michel; Isebaert, Sofie; Joniau, Steven; Deroose, Christophe M.; Oyen, Raymond; Lerut, Evelyne; Budiharto, Tom; Mottaghy, Felix; Bormans, Guy; Van Poppel, Hendrik; Haustermans, Karin

    2012-01-01

    Purpose: To investigate the additional value of 11 C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and 11 C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze 11 C-choline PET-CT images, the same grid was used to calculate the standardized uptake values (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For 11 C-choline PET-CT, the mean SUV max of malignant octants was significantly higher than the mean SUV max of benign octants (3.69 ± 1.29 vs. 3.06 ± 0.97, p mean values (2.39 ± 0.77 vs. 1.94 ± 0.61, p mean and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV max cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV max but at the cost of specificity. When only considering suspect octants on 11 C-choline PET-CT (SUV max ≥ 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value of 11 C-choline PET-CT next to T2w MRI in detecting tumor nodules within the prostate is limited.

  14. Biplane CT in sellar and parasellar tumors, (2)

    International Nuclear Information System (INIS)

    Sadamoto, Kazuhiko; Sakaki, Saburo; Matsuoka, Kenzo; Goishi, Junji; Sokabe, Takashi.

    1980-01-01

    Biplane CT images of 30 cases of sellar and parasellar tumors were studied. All 3 cases of meningioma were discovered by biplane CT (the diagnostic rate, 100%). As biplane CT could exclude partial volume effects, biplane CT images could demonstrate a fine structure and the position of parasellar or skull-base meningioma. As features of craniopharyngioma visualized on biplane CT images were variable, 7 of 9 cases of craniopharyngioma were detected by biplane CT (the diagnostic rate, 80%). When contrast enhancement on biplane CT images was marked, sometimes differencial diagnosis of craniopharyngioma and other suprasellar tumors was difficult. In all 18 cases of chromophobe adenoma, biplane CT images successfully demonstrated the location and extension of the tumors including cystic tumor (the diagnostic rate, 100%). In addition, 2 cases of giant aneurysm were presented in this study as examples of the differential diagnosis of pituitary and supraseller tumors. Biplane CT images showed mainly the location and the size of aneurysm as a mass lesion: therefore, cerebral angiography including vertebral arteriography was necessary for making an exact diagnosis of aneurysm. (Tsunoda, M)

  15. Pediatric brain tumors; Kindliche Hirntumoren

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Bodea, S. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany); Muehl-Benninghaus, R.

    2017-09-15

    Brain tumors differ between children and adults both in histology and localization. Malignant gliomas and meningiomas predominate in adults while medulloblastomas and low-grade astrocytomas are the most frequent brain tumors in children. More than one half (50-70%) of pediatric brain tumors have an infratentorial location but only approximately 30% in adults. Brain tumors can be recognized in sonography, cranial computed tomography (CCT) and magnetic resonance imaging (MRI) by their space-consuming character and by their divergent density and intensity in comparison to normal brain parenchyma. They can grow extrusively, even infiltrate the parenchyma or originate from it. Besides clinical symptoms and diagnostics this article describes the most common pediatric brain tumors, i.e. astrocytoma, medulloblastoma, brainstem glioma, craniopharyngioma, neurofibromatosis and ganglioglioma. The most important imaging criteria are outlined. (orig.) [German] Sowohl Histologie als auch Lokalisation von Hirntumoren unterscheiden sich bei Kindern und Erwachsenen. Waehrend maligne Gliome und Meningeome bei Erwachsenen vorherrschen, kommen bei Kindern ueberwiegend Medulloblastome und niedriggradige Astrozytome vor. Mehr als die Haelfte (50-70 %) aller kindlichen Hirntumoren sind infratentoriell lokalisiert, dagegen sind es bei Erwachsenen nur etwa 30 %. Im Ultraschall, in der kranialen CT (CCT) oder MRT koennen Hirntumoren durch ihren raumfordernden Charakter und ihrer zum normalen Parenchym abweichenden Dichte oder Signalintensitaet erkannt werden. Sie koennen verdraengend wachsen, z. T. auch das Parenchym infiltrieren oder von diesem ausgehen. Neben der klinischen Symptomatik und Diagnostik werden im vorliegenden Artikel die haeufigsten kindlichen Hirntumoren, das Astrozytom, Medulloblastom, Hirnstammgliom, Kraniopharyngeom, die Neurofibromatose und das Gangliogliom beschrieben. Die wichtigsten bildgebende Kriterien werden dargestellt. (orig.)

  16. Hyperdensity liver tumor on plain CT

    Energy Technology Data Exchange (ETDEWEB)

    Hirota, Shozo; Hanaguri, Katsuro [Kochi Municipal Central Hospital (Japan); Shimizu, Masahumi; Sako, Masao; Harada, Yasushi

    1984-12-01

    Most liver tumors on plain CT have been recognized as low density or iso-density masses. Sometimes calcified high density masses were shown on plain CT in case of cysts or metastatic liver tumors. However, hyperdensity mass of the liver on CT, of which the density was a little higher than surrounding tissues, was very rare. Recently 7 patients with hyperdensity liver masses on plain CT were experienced: 6 hepatocellular carcinomas and 1 hepatic cavernous hemangioma. A single hyperdensity mass was shown in 4 patients, a hyperdensity mass of multiple hepatic tumors was shown in 2 patients, and some hyperdensity masses of multiple hepatic tumors were shown in 1 patient. Lesions are classified in 3 types according to the appearance of hyperdensity masses: diffuse hyperdensity all over the mass, ring like hyperdensity, creascent like hyperdensity. Intravenous contrast enhancement was performed in 2 patients: one with a primary hepatocellular carcinoma, and another with a hepatic cavernous hemangioma. In the former case the tumor margin had changed unclear, in the latter case the tumor was markedly enhanced. Our results revealed that hyperdensity liver tumors were divided into 2 types: One type, shown in a cavernous hemangioma with fatty liver, demonstrated relative hyperdensity due to lower density of the surrounding tissue. Another type, shown in 6 hepatocellular carcinomas, showed hyperdensity since the density of the tumor was hyperdensity relative to the surrounding tissue of the liver. It was suggested that the tumor with the latter type had been strongly probable of malignant one, and been recommended to receive further examination. Cause of hyperdensity was thought to be due to hemorrhage, though microcalcification could not be denyed. In Japan, no hyperdensity liver tumor had been reported partly due to a wide window width with which CT photographs were taken.

  17. CT staging of renal pelvis tumor

    International Nuclear Information System (INIS)

    Yoon, Soo Woong; Cho, Kyoung Sik; Lee, Jong Hwa; Ham, Su Yeon; Won, Yeong Cheol; Ji, Eun Kyung; Choi, Seong Hun; Shin, Byung Suck

    1999-01-01

    To assess the value of computed tomography (CT) in the preoperative staging of transitional cell carcinoma (TCC) of the renal pelvis. We retrospectively evaluated the CT TNM staging of 38 patients with TCC of the renal pelvis who had undergone preoperative abdominal CT examination between January 1990 and January 1998. In CT staging for differentiation between early-stage (T0-2) and advanced-stage disease (T3-T4), three criteria were used, namely the presence or obliteration of the renal sinus fat layer, the smoothness or irregularity of margin between the tumor and renal parenchyma, and the presence or absence of hydronephrosis proximal to the tumor. CT staging was performed by two genitourinary radiologists blinded to the pathologic results, and was compared with pathologic staging. Pathologic results revealed 19 cases of early stage disease (T0=8, T1=9, T2=2) and 19 of advanced stage (T3=12, T4=7). Overall CT staging accuracy was 82%(31/38) ; four cases were overstaged and three were understaged. In early-stage disease, sensitivity and specificity were 79%, and 84%, and in advanced stage disease were 83% and 80%. Three of four overstaged cases showed hydronephrosis proximal to the tumor. In the second CT staging, using proximal hydronephrosis of the tumor as a criterion for early-stage disease, the sensitivity and specificity of early-stage disease were 95% and 75%, respectively, and the specificity of advanced-stage disease was 95%. When hydronephrosis proximal to a tumor was considered to be a sign of early stage disease, the CT staging of renal pelvic TCC was highly accurate

  18. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  19. CT findings of parotid gland tumors: benign versus malignant tumors

    International Nuclear Information System (INIS)

    Lee, Moon Ok; Han, Chun Hwan; Kim, Mie Young; Yi, Jeong Geun; Park, Kyung Joo; Lee, Joo Hyuk; Bae, Sang Hoon; Kim, Jeung Sook

    1994-01-01

    The purpose of this study is to evaluate the characteristics of parotid gland tumors to help in the differentiation between benign and malignant lesions. The CT findings of 22 patients with surgically proven parotid gland tumors were reviewed. Analysis was focused on the density and margin characteristics of the tumors, and the relationship between the tumor and surrounding structures. Those tumors were pleomorphic adenoma (n = 8), Warthin's tumor (n = 5), basal cell adenoma (n = 1), lipoma (n = 1), dermoid cyst (n = 1), adenoid cystic carcinoma (n = 2), mucoepidermoid carcinoma (n 1), epidermoid carcinoma (n = 1), and carcinoma in pleomorphic adenoma (n 1). Most of benign and malignant tumors were heterogeneous in density on contrast enhanced CT scans. In 5 of 6 malignant cases, the tumors had irregular or ill-defined margin and a tendancy to involve or cross the superficial layer of deep cervical fascia with obliteration of subcutaneous fat. Two malignant tumors invaded surrounding structures. Although the heterogeneous density of tumor is not a specific finding for malignancy at CT, following findings, such as, irregular or blurred margin of the lesion, the involvement of fascial plane, and the infiltration of surrounding structures may suggest the possibility of malignant parotid tumor

  20. How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kahn, Johannes; Grupp, Ulrich; Maurer, Martin

    2014-01-01

    Purpose: To evaluate the influence of different arm positions on abdominal image quality during initial whole-body CT (WBCT) in polytraumatized patients and to assess the risk of missing potentially life-threatening injuries due to arm artifacts. Materials and methods: Between July 2011 and February 2013, WBCT scans of 203 patients with arms in the abdominal area during initial WBCT were analyzed. Six different arms-down positions were defined: patients with both (group A)/one arm(s) (group B) down alongside the torso, patients with both (group C)/one arm(s) (group D) crossed in front of the upper abdomen, patients with both (group E)/one arm(s) (group F) crossed in front of the pelvic area. A group of 203 patients with elevated arms beside the head served as a control group. Two observers jointly evaluated image quality of different organ regions using a 4-point scale system. Follow-up examinations (CT scans and/or ultrasound) were analyzed to identify findings missed during initial WBCT due to reduced image quality. Results: Image quality for most of the organ regions analyzed was found to be significantly different among all groups (p < 0.05). Image quality was most severely degraded in group A, followed by groups E and C. Positioning with one arm up resulted in significantly better image quality than both arms down (p < 0.05). Overall, arms-up positioning showed significantly better image quality than arms-down positions (p < 0.05). In one case, liver hemorrhage missed in the initial WBCT because of arm artifacts, was revealed by follow-up CT. Conclusion: In WBCT arms-down positioning significantly degrades abdominal image quality and artifacts might even conceal potentially life-threatening injuries. If the patient's status does not allow elevation of both arms, image quality can benefit from raising at least one arm. Otherwise, arms should be placed in front of the upper abdomen instead of alongside the torso

  1. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  2. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  3. Pneumonia in immunosuppressed patients; Pneumonien bei immunsupprimierten Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Solyanik, O.; Gaass, T.; Hellbach, K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer klinische Radiologie, Muenchen (Germany); Dinkel, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer klinische Radiologie, Muenchen (Germany); Comprehensive Pneumology Center Munich (CPC-M), Muenchen (Germany)

    2017-01-15

    Pulmonary infections are a common complication in immunosuppressed patients with a frequently fatal prognosis despite modern prophylactic therapy. An early and correct diagnosis is important for initiation of the appropriate therapy. Chest radiography is the preferred initial imaging examination but is not accurate enough for the detection of pulmonary infections in immunosuppressed patients. Pneumonia is caused by a broad spectrum of pathogens in immunocompromised patients. In addition to imaging, the clinical history and epidemiology also play an important role in the diagnostics. Using epidemiological and anamnestic information, computed tomography (CT) shows a significantly better sensitivity and specificity particularly for the diagnosis of atypical forms of pneumonia. Due to the exact imaging of the different infiltration patterns CT provides an increased sensitivity with respect to the etiological classification of pulmonary infections. This article reviews in particular the radiological findings of commonly occurring pulmonary infections in immunosuppressed patients. (orig.) [German] Pneumonien bei immunsupprimierten Patienten sind haeufige Komplikationen, die trotzt moderner Prophylaxe toedlich verlaufen koennen. Eine korrekte Diagnose ist daher von entscheidender Bedeutung, um die richtige Therapie einleiten zu koennen. Die Roentgenthoraxaufnahme ist selten spezifisch genug fuer die genaue Einordnung atypischer Pneumonien in Folge einer Immunsuppression. Pneumonien unter Immunsuppression werden durch ein sehr breites Erregerspektrum verursacht. Eine wichtige Rolle bei der Diagnosefindung spielen neben der Bildgebung auch die klinische Anamnese und Epidemiologie. Mithilfe der klinischen Anamnese und Epidemiologie bietet die Computertomographie (CT) bei immunsupprimierten Patienten zum einen eine erhoehte Sensitivitaet bei der Detektion insbesondere atypischer Pneumonien. Zum anderen weist die CT durch die exakte Abbildung unterschiedlicher Infiltratmuster

  4. Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B. [Department for Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover (Germany); Renne, Julius; Wacker, Frank K.; Meyer, Bernhard C. [Department for Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany); Hoeper, Marius M.; Olsson, Karen M. [Clinic for Pneumology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany)

    2016-11-15

    To investigate the feasibility of and compare two C-Arm CT (CACT) guidance methods during balloon pulmonary angioplasty (BPA). Forty-two BPAs [27 CTEPH patients (nine males, 70 ± 14y)] targeting 143 pulmonary arteries were included. Twenty-two BPAs were guided by contrast-enhanced CACT acquired immediately before BPA (G3D). In another 20 BPAs (G2D), two orthogonal fluoroscopy images of the chest where acquired to compute a registration of a previously acquired CACT. Volume rendering-based graphic representations (VRT guidance) were generated indicating the origin and course of the vessels. Based on VRT guidance, the intervention was planned. Procedure durations and radiation exposure data were compared between the two groups (Wilcoxon test). The overall intervention time was approximately 2 h in both groups (p = 0.31). BPA was successfully performed in G3D 91 % and G2D 94 %. No significant difference was found concerning the mean dose area product (DAP) related to fluoroscopy (p = 0.38), while DAP related to DSA was slightly higher in G3D (p = 0.048). Overall, DAP was significantly higher in G3D (p = 0.002). The use of CACT for procedure guidance in patients undergoing BPA is feasible and accurate. Image fusion of a pre-acquired CACT can be used to decrease radiation exposure due to multiple BPA sessions. (orig.)

  5. Diagnosis of ovarian tumors by ultrasonography and x-ray CT

    International Nuclear Information System (INIS)

    Watanabe, Hiromu

    1986-01-01

    A drawback in ultrasonography, an indispensable technique in imaging ovarian malignancies, is that it sometimes shows false positive for benign tumors including dermoid cyst and ovarian endometriosis. To overcome this, the concurrent use of X-Ray CT seems warrantable and this led us to carry out the study summarized below. CT was carried out on 268 of 322 ovarian disease cases which had undergone ultrasonography. The results obtained were as follows. Sensitivity of ultrasonography and CT in ovarian malignancies were 82 % and 88 % respectively. Of the cases subjected to both techniques, those who were deemed false positive were 39 in ultrasonography and 12 in CT. Ultrasonographic imagings of dermoid cyst and ovarian endometriosis were classified on the basis of their patterns. The results obtained revealed that those in which it was difficult to discriminate the image from ovarian malignancy were types V and VI in dermoid cyst and type III-C in ovarian endometriosis. In both dermoid cyst and ovarian endometriosis, nearly a 100 % accuracy rate was obtainable with CT for diagnosis of benign tumors. This strongly suggested that concurrent use of CT was required, in diagnosing ovarian diseases with the V or VI and III-C patterns referred to above. (author)

  6. Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection

    Science.gov (United States)

    Li, Yinsheng; Garrett, John W.; Li, Ke; Wu, Yijing; Johnson, Kevin; Schafer, Sebastian; Strother, Charles; Chen, Guang-Hong

    2018-04-01

    Time-resolved C-arm cone-beam CT (CBCT) angiography (TR-CBCTA) images can be generated from a series of CBCT acquisitions that satisfy data sufficiency condition in analytical image reconstruction theory. In this work, a new technique was developed to generate TR-CBCTA images from a single short-scan CBCT data acquisition with contrast media injection. The reconstruction technique enabling this application is a previously developed image reconstruction technique, synchronized multi-artifact reduction with tomographic reconstruction (SMART-RECON). In this new application, the acquired short-scan CBCT projection data were sorted into a union of several sub-sectors of view angles and each sub-sector of view angles corresponds to an individual image volume to be reconstructed. The SMART-RECON method was then used to jointly reconstruct all of these individual image volumes under two constraints: (1) each individual image volume is maximally consistent with the measured cone-beam projection data within the corresponding view angle sector and (2) the nuclear norm of the image matrix is minimized. The difference between these reconstructed individual image volumes is used to generated the desired subtracted angiograms. To validate the technique, numerical simulation data generated from a fractal tree angiogram phantom were used to quantitatively study the accuracy of the proposed method and retrospective in vivo human subject studies were used to demonstrate the feasibility of generating TR-CBCTA in clinical practice.

  7. Utility of “1”1C -methionine PET/CT in neuro-oncology

    International Nuclear Information System (INIS)

    Casas Parera, I.; Igirio Gamero, J.L.; Báez, A.; Tafur Canabal, J.G.; Báez, M.; Kuchkaryan, V.; B lumenkrantz, Y.; Bruno, G.

    2013-01-01

    Positron emission tomography (PET) with “1”1C-methionine (“1”1C-methionine PET/CT) is a new technique used to evaluate primary central nervous system (CNS) tumors. We describe our experience regarding the first 4 patients with glial tumors and “1”1C-methionine PET/CT. This is a descriptive, observational and prospective study of 4 patients between 38-50 years of age, with different gliomas (WHO classification). MRI and “1”1C-methionine PET/CT were performed in all cases. Case 1, gliomatosis cerebri grade II post-radiotherapy. Case 2, oligodendroglioma grade II diagnosed and treated with radiotherapy in 1993. Case 3, glioblastoma grade IV post-radiotherapy + temozolomide. Case 4, anaplastic oligoastrocytoma grade III post-radiotherapy + temozolomide. The pattern of “1”1C-methionine uptake compared with MRI showed tumor progression in cases 1, 3 and 4, and in case 2 showed uptake although the final diagnosis was pseudoprogression. Unlike “1”8fluordeoxiglucose PET/TC, “1”1C-methionine uptake in normal brain tissue and pseudoprogression is low, and gliomas are displayed as metabolically active areas. The “1”1C-methionine PET/CT provided valuable information on the tumoral behavior and extension, although in one case presented did not differentiate tumor progression from pseudoprogression. “1”1C-methionine PET/CT could be a useful tool in the study and follow-up to patients with gliomas. (authors) [es

  8. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    International Nuclear Information System (INIS)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor

    2011-01-01

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  9. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor [School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); Vancouver Cancer Centre, Vancouver, British Columbia V5Z-1E6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada)

    2011-10-15

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 {+-} 0.44 mm (Mean {+-} STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 {+-} 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  10. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

    International Nuclear Information System (INIS)

    Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas; McWalter, Emily J.; Gold, Garry E.; Fahrig, Rebecca; Pal, Saikat; Beaupré, Gary S.

    2014-01-01

    Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D

  11. Importance of multidetector CT imaging in multiple trauma; Stellenwert der Multidetektor-CT bei Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U. [HELIOS Kliniken Muenchen West, HELIOS Klinik Muenchen Perlach, Institut fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Geyer, L.L.; Reiser, M.; Wirth, S. [Klinikum der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Koerner, M. [Radiologie Muehleninsel, Landshut (Germany)

    2014-09-15

    zeitnahe Therapie mit dem Ziel, potenziell lebensbedrohliche Verletzungen fruehzeitig zu erkennen und adaequat zu behandeln. Die Basisdiagnostik triagiert zur Sofortoperation und besteht unveraendert aus einer fokussierten Ultraschalluntersuchung (Focused Assessment with Sonography for Trauma, FAST) und Projektionsradiographie (CR), meist limitiert auf eine einzelne Thoraxaufnahme. Die Multidetektor-CT (MDCT) hat sich als standardisierte fruehe Ganzkoerper-CT (''whole-body'', WBCT) etabliert; die Detektionsrate von Verletzungen ist herausragend und die Ueberlebenswahrscheinlichkeit verbessert sich um 20-25 %. Die raeumliche und zeitliche Aufloesung wurde verbessert und die Untersuchungszeit erheblich verkuerzt. Die Dosisexposition ist auch bei einmaliger Akutanwendung nicht unerheblich, durch moderne Scannertechnologie und Dosisreduktion, einschliesslich der iterativen Bildrekonstruktion, konnte eine Dosisreduktion von bis zu 40 % erreicht werden. Die zahlreichen Bilder der WBCT muessen prioritaetenorientiert hergestellt, befundet und archiviert werden, zur schnellen Diagnostik bietet sich das ''volume image reading'' (VIR) an. Die moderne WBCT wir bei Polytrauma frueh, umfassend und individuell adaptiert durchgefuehrt, dabei verbessert die WBCT die Ueberlebenswahrscheinlichkeit um 20-25 %. (orig.)

  12. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  13. Bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles as novel tumor targeting carriers

    International Nuclear Information System (INIS)

    Ding Hong; Yong, Ken-Tye; Roy, Indrajit; Hu Rui; Zhao Lingling; Law, Wing-Cheung; Ji Wei; Liu Liwei; Bergey, Earl J; Prasad, Paras N; Wu Fang; Zhao Weiwei

    2011-01-01

    In this study, we have developed a novel carrier, micelle-type bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles (NPs), for the detection and treatment of pancreatic cancer. These NPs contained 4-arm-PEG as corona, and PLGA as core, the particle surface was conjugated with cyclo(arginine-glycine-aspartate) (cRGD) as ligand for in vivo tumor targeting. The hydrodynamic size of the NPs was determined to be 150-180 nm and the critical micellar concentration (CMC) was estimated to be 10.5 mg l -1 . Our in vitro study shows that these NPs by themselves had negligible cytotoxicity to human pancreatic cancer (Panc-1) and human glioblastoma (U87) cell lines. Near infrared (NIR) microscopy and flow cytometry demonstrated that the cRGD conjugated PLGA-4-arm-PEG polymeric NPs were taken up more efficiently by U87MG glioma cells, over-expressing the α v β 3 integrin, when compared with the non-targeted NPs. Whole body imaging showed that the cRGD conjugated PLGA-4-arm-PEG branched polymeric NPs had the highest accumulation in the pancreatic tumor site of mice at 48 h post-injection. Physical, hematological, and pathological assays indicated low in vivo toxicity of this NP formulation. These studies on the ability of these bioconjugated PLGA-4-arm-PEG polymeric NPs suggest that the prepared polymeric NPs may serve as a promising platform for detection and targeted drug delivery for pancreatic cancer.

  14. Bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles as novel tumor targeting carriers

    Energy Technology Data Exchange (ETDEWEB)

    Ding Hong; Yong, Ken-Tye; Roy, Indrajit; Hu Rui; Zhao Lingling; Law, Wing-Cheung; Ji Wei; Liu Liwei; Bergey, Earl J; Prasad, Paras N [Department of Chemistry, Institute for Lasers, Photonics and Biophotonics, University at Buffalo, State University of New York, Buffalo, NY 14260 (United States); Wu Fang [Department of Pharmaceutical Sciences, University at Buffalo, State University of New York, Buffalo, NY 14260 (United States); Zhao Weiwei, E-mail: bergeye@buffalo.edu, E-mail: pnprasad@buffalo.edu [Department of Microbiology and Immunology, University at Buffalo, State University of New York, Buffalo, NY 14215 (United States)

    2011-04-22

    In this study, we have developed a novel carrier, micelle-type bioconjugated PLGA-4-arm-PEG branched polymeric nanoparticles (NPs), for the detection and treatment of pancreatic cancer. These NPs contained 4-arm-PEG as corona, and PLGA as core, the particle surface was conjugated with cyclo(arginine-glycine-aspartate) (cRGD) as ligand for in vivo tumor targeting. The hydrodynamic size of the NPs was determined to be 150-180 nm and the critical micellar concentration (CMC) was estimated to be 10.5 mg l{sup -1}. Our in vitro study shows that these NPs by themselves had negligible cytotoxicity to human pancreatic cancer (Panc-1) and human glioblastoma (U87) cell lines. Near infrared (NIR) microscopy and flow cytometry demonstrated that the cRGD conjugated PLGA-4-arm-PEG polymeric NPs were taken up more efficiently by U87MG glioma cells, over-expressing the {alpha}{sub v{beta}3} integrin, when compared with the non-targeted NPs. Whole body imaging showed that the cRGD conjugated PLGA-4-arm-PEG branched polymeric NPs had the highest accumulation in the pancreatic tumor site of mice at 48 h post-injection. Physical, hematological, and pathological assays indicated low in vivo toxicity of this NP formulation. These studies on the ability of these bioconjugated PLGA-4-arm-PEG polymeric NPs suggest that the prepared polymeric NPs may serve as a promising platform for detection and targeted drug delivery for pancreatic cancer.

  15. Dissection or irradiation of the axilla in postmenopausal patients with breast cancer? Long-term results and late effects in 655 patients; Axilladissektion oder Axillabestrahlung bei postmenopausalen Patientinnen mit Mammakarzinom?

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, M.R.; Zink, K.; Ruehl, U. [Abt. fuer Strahlentherapie, Klinikum im Friedrichshain, Standort Moabit, Berlin (Germany); Busch, W. [Abt. fuer Gynaekologie, Krankenhaus Moabit Berlin (Germany)

    2002-09-01

    Patients and methods: From 1986 to 1993 we irradiated 655 patients with breast cancer after breast conserving surgery (BET). In all 144 cN1- and all 209 premenopausal cNO-patients axillary dissection was recommended. Of 302 postmenopausal cNO-patients 129 had breast surgery in our institution. In a total of 129 patients axillary dissection was replaced by irradiation (AxRT-group). They were compared with all 173 patients referred from other hospitals for irradiation after both breast conserving surgery and axillary dissection (AxOP-group). Dissected patients with gross tumor involvement of the axilla or less than eight nodes removed had additional axillary irradiation. Patients age, tumor size, vessel-, muscle- or skin invasion and grading were similar in both groups. However, in the AxRT-group there were more patients with negative hormon receptors, multifocal and medial sited tumors. Late complications after dissection and/or irradiation of the axilla were evaluated in 502 patients free of locoregional relapse and with a minimal follow up of 3 years (media 9,5 years). Results: After 5, 10 and 15 years tumor free survival rated were 90%, 82% and 79% in the AxOP-group vs 91%, 82% and 80% in the AxRT-group, respectively (p = 0.95). Overall survival (p = 0.98) local (p = 0.47) and axillary control (p = 0.12) were equal in both groups. However, serious problems like lymphedema of the arm, pain, mobility impairment occured in 26% patients following axillary dissection but only in 1% after axillary irradiation. No difference in late sequelae after axillary dissection with or without irradiation could be detected (26 vs 27%). (orig.) [German] Patientinnen und Methoden: Von 1986 bis 1993 wurden 655 Patientinnen mit Mammakarzinom nach brusterhaltender Operation (BET) bestrahlt. Davon waren praeoperativ 144 cN1- und 511 cNO-Patientinnen. Bei allen 144 cN1- und allen 209 praemenopausalen cNO-Patientinnen war eine Axilladissektion vorgesehen. Von 302 postmenopausalen c

  16. CT-sialographic evaluation of 19 cases of alivary gland tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tadashi [Komoro Kousei General Hospital, Nagano (Japan)

    1999-09-01

    Sixteen patients with parotid gland tumors and 3 patients with submandibular gland tumors were evaluated by CT sialography. The 19 patients were 5 to 78 years old, mean age: 57.3 years. CT sialography was performed preoperatively, and postoperative histological examination indicated that the tumors were benign in 13, a cyst in 1, malignant tumors in 4, and a malignant lymphoma in 1 patient. The tumorous lesion detection rate by CT sialography was 100%. The major duct was visualized in all patients, and the examination was informative about the special relationship between the tumor and the facial nerve. No sign of malignancy was noted in an epithelialmyoepithelial carcinoma of 10 mm in diameter on CT sialography. In 2 patients adhesion to surrounding tissues observed intraoperatively was judged to be benign tumors by CT sialography. The marginal morphology of the tumor and the presence or absence of low density areas and punctuate leakage in the interior of the tumor were useful for the judgement of malignancy of salivary gland tumors. CT sialography, which provides diverse information on the location and morphology of the tumor, should be performed early for the diagnosis of salivary gland tumors. (author)

  17. 68Ga DOTA-TATE PET/CT allows tumor localization in patients with tumor-induced osteomalacia but negative 111In-octreotide SPECT/CT.

    Science.gov (United States)

    Breer, Stefan; Brunkhorst, Thomas; Beil, F Timo; Peldschus, Kersten; Heiland, Max; Klutmann, Susanne; Barvencik, Florian; Zustin, Jozef; Gratz, Klaus-Friedrich; Amling, Michael

    2014-07-01

    Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by renal phosphate wasting, hypophosphatemia and low calcitriol levels as well as clinical symptoms like diffuse bone and muscle pain, fatigue fractures or increased fracture risk. Conventional imaging methods, however, often fail to detect the small tumors. Lately, tumor localization clearly improved by somatostatin-receptor (SSTR) imaging, such as octreotide scintigraphy or octreotide SPECT/CT. However, recent studies revealed that still a large number of tumors remained undetected by octreotide imaging. Hence, studies focused on different SSTR imaging methods such as 68Ga DOTA-NOC, 68Ga DOTA-TOC and 68Ga DOTA-TATE PET/CT with promising first results. Studies comparing different SSTR imaging methods for tumor localization in TIO are rare and thus little is known about diagnostic alternatives once a particular method failed to detect a tumor in patients with TIO. Here, we report the data of 5 consecutive patients suffering from TIO, who underwent both 111Indium-octreotide scintigraphy (111In-OCT) SPECT/CT as well as 68Ga DOTA-TATE PET/CT for tumor detection. While 111In-OCT SPECT/CT allowed tumor detection in only 1 of 5 patients, 68Ga DOTA-TATE PET/CT was able to localize the tumor in all patients. Afterwards, anatomical imaging of the region of interest was performed with CT and MRI. Thus, successful surgical resection of the tumor was achieved in all patients. Serum phosphate levels returned to normal and all patients reported relief of symptoms within weeks. Moreover, an iliac crest biopsy was obtained from every patient and revealed marked osteomalacia in all cases. Follow-up DXA revealed an increase in BMD of up to 34.5% 1-year postoperative, indicating remineralization. No recurrence was observed. In conclusion our data indicates that 68Ga DOTA-TATE PET/CT is an effective and promising diagnostic tool in the diagnosis of TIO, even in patients in whom 111In-OCT prior failed to detect

  18. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    Science.gov (United States)

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  19. CT morphology of benign median nerve tumors

    International Nuclear Information System (INIS)

    Feyerabend, T.; Schmitt, R.; Lanz, U.; Warmuth-Metz, M.; Wuerzburg Univ.

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.)

  20. Judgement of the effectivity of radiotherapy on the basis of volume change by lymph node metastasis of head and neck tumors; Volumenveraenderung der Halslymphknotenmetastasen bei Kopf-Hals-Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Liszka, G. [Staatliches Onkologisches Inst., Budapest (Hungary). Roentgendiagnostische Abt.; Thalacker, U. [Staatliches Onkologisches Inst., Budapest (Hungary). Roentgendiagnostische Abt.; Somogyi, A. [Imre-Haynal-Universitaet fuer Gesundheitswissenschaften, Budapest (Hungary). Strahlentherapeutischer Lehrstuhl; Nemeth, G. [Imre-Haynal-Universitaet fuer Gesundheitswissenschaften, Budapest (Hungary). Strahlentherapeutischer Lehrstuhl

    1997-08-01

    Aim: This work is engaged with the volume change of neck lymph node metastasis of malignant tumors in the head-neck region during radiotherapy. Patients and Method: In 54 patients with head and neck tumors, the volume of neck lymph nodes before and after radiation was measured. The volumetry was done with CT planimetry. The total dose was 66 Gy (2 Gy/d) telecobalt from 2 lateral opponated fields. The time of volume change could be defined with measuring of the half-time and the doubling-time by the help of Schwartz formula. Results: After 10 Gy the volume diminution was about 20% and half-time 24 to 26 days. Afterwards the time of volume diminution picked up speed and finally achieved 60 to 72%. Meanwhile the half-time decreased to the half value. The result was independent of the site of primary tumor, the patient`s sex and age. (orig.) [Deutsch] Ziel: Diese Arbeit beschaeftigt sich mit der Volumenveraenderung von Halslymphknotenmetastasen maligner Tumoren im Kopf-Hals-Bereich waehrend einer strahlentherapeutischen Behandlung. Patienten und Methode: Bei 54 Patienten mit Kopf-Hals-Tumoren wurde das Volumen der Halslymphknotenmetastasen vor und nach Strahlenbehandlung (bei sieben Patienten auch nach 10 Gy) bestimmt. Der Primaertumor war in allen Faellen ein Plattenepithelkarzinom. Zur Bestimmung des Volumens der Lymphknotenmetastasen bietet sich als genauestes bildgebendes Verfahren die CT-Planimetrie an. Jeder Patient wurde mit Telekobalt ueber zwei opponierende laterale Felder bis zu einer Gesamtdosis von 66 Gy (taegliche Einzeldosis 2 Gy) bestrahlt. Die Dynamik der durch die Bestrahlung hervorgerufenen Volumenveraenderung wurde mit Hilfe der Halbwerts- bzw. Verdoppelungszeit nach der Formel von Schwartz berechnet. Ergebnisse: Nach 10 Gy betrug die Volumenverkleinerung etwa 20%, die Halbwertszeit 24 bis 26 Tage. Danach beschleunigte sich die Volumenverkleinerung und erreichte zuletzt 60 bis 72%. Die Halbwertszeit verringerte sich auf etwa die Haelfte. Das Ausmass

  1. Clinical evaluation of high-resolution CT, 1. CT diagnosis of liver tumors and its limit

    Energy Technology Data Exchange (ETDEWEB)

    Araki, T [Tokyo Univ. (Japan). Faculty of Medicine

    1980-03-01

    To estimate diagnostic accuracy of CT in liver tumors, CT diagnosis in 120 patients with primary hepatocellular carcinoma was discussed. As a result, primary hepatocellular carcinoma less than 2 cm in diameter could not be visualized by CT. Even tumors between 4 and 8 cm in diameter showed false negative caused by isodense tumors on images of 4 patients. To improve the detectability of liver tumors by CT, the higher resolution of low contrast regions on images are required. As a method to improve qualitative diagnosis of liver tumors, rapid intravenous injection of contrast medium was performed on 42 patients with liver tumors, As a result, images reflecting vascularity of tumors were obtained, and the differential diagnosis was possible to some extent by observing the movement of the contrast. Especially, cavernous hemangioma could be distinguished from hepatocellular carcinoma, because cavernous hemangioma showed specific images and could be diagnosed accurately.

  2. The role of CT in diagnosing small hepatic tumors

    International Nuclear Information System (INIS)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi

    1992-01-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author)

  3. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  4. PET-CT and PET-MRI of the prostate. From {sup 18}F-FDG to {sup 68}Ga-PSMA; PET-CT/-MRT der Prostata. Von {sup 18}F-FDG zu {sup 68}Ga-PSMA

    Energy Technology Data Exchange (ETDEWEB)

    Knorr, K.; Eiber, M.; Scheidhauer, K. [Technische Universitaet Muenchen, Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Maurer, T. [Technische Universitaet Muenchen, Urologische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Wester, H.J. [Technische Universitaet Muenchen, Pharmazeutische Radiochemie, Garching (Germany)

    2017-08-15

    In the last few years nuclear medical diagnostics have experienced a unprecedented renaissance in the diagnostics of prostate cancer, due to the availability of hybrid imaging with positron emission tomography computed tomography (PET/CT), PET magnetic resonance imaging (PET/MRI) and single photon emission computed tomography (SPECT) CT as well as the development of prostate-specific radiopharmaceuticals. The use of fluorodeoxyglucose (FDG), which has been successfully implemented for many years in PET diagnostics, is only helpful in dedifferentiated tumors due to the biological characteristics of prostate cancer. New specific radiopharmaceuticals, such as choline-derivatives, which are incorporated into the prostate cancer cell and built into the cell membrane as well as the recently developed highly specific ligands for prostate-specific membrane antigen (PSMA) are revolutionizing prostate cancer imaging and (re-) staging. The {sup 68} Ga-labeled PSMA ligands for PET-CT and PET-MRI are highly specific tracers for primary diagnostics and detection of metastases of prostate carcinoma. In risk patients, which includes patients with intermediate and high-risk tumors, they have largely replaced choline-based PET-CT, especially in the case of very low PSA values <0.5 ng/ml in the diagnostics of recurrence. The use in the primary diagnostics as PET-MRI, also in combination with multiparametric MRI (mpMRI), is promising with respect to early diagnostics and image fusion-assisted biopsy as well as surgery and irradiation planning. (orig.) [German] Die nuklearmedizinische Diagnostik hat in den letzten Jahren bei der Bildgebung des Prostatakarzinoms eine rasante Entwicklung erlebt, sowohl aufgrund der verfuegbaren Hybridbildgebung mit der Positronenemissionstomographie(PET)-CT, PET-MRT sowie der Single-photon-emission-computed-tomography(SPECT)-CT als auch durch die Entwicklung prostataspezifischer Radiopharmaka. Die in der PET-Diagnostik seit Jahren erfolgreich eingesetzte

  5. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    International Nuclear Information System (INIS)

    Ritschl, Ludwig; Fleischmann, Christof; Kuntz, Jan; Kachelrieß, Marc

    2016-01-01

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation

  6. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    Energy Technology Data Exchange (ETDEWEB)

    Ritschl, Ludwig; Fleischmann, Christof [Ziehm Imaging GmbH, Donaustraße 31, Nürnberg 90451 (Germany); Kuntz, Jan, E-mail: j.kuntz@dkfz.de; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany)

    2016-05-15

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation

  7. Technique improvement of thoracoabdominal CT scan for patients with arm-raising disability

    International Nuclear Information System (INIS)

    Yuan Zhidong; Liu Yuanjian; Jiang Guoyin; Feng Fei; Wang Chenglin; Liu Pengcheng

    2010-01-01

    Objective: To explore a new scanning technique to reduce and avoid image artifacts of thoracoabdominal CT and improve image quality for patients who cannot raise their arms. Methods: Sixty-one patients with arm-raising disability between March 2004 and May 2009 were enrolled in the study. Thirty-one cases before June 2007 were scanned with their arms beside their body (control group), 30 cases after June 2007 were scanned with their arms shifting to different imaging planes of the spine (study group), and another 30 patients who can raising their arms were taken as routine group. The images artifacts were blindly evaluated by 5-points scale (severe, less severe, moderate, minimum and no artifact) by 2 experienced CT technologists and one radiologist and compared between the three groups (X 2 test). CT values and its noise of the liver with or without artifact of the three groups were measured and analyzed by one-way ANOVA test. Results: In the control group, 11 cases had severe, 15 cases had less severe, 5 cases had moderate. In the study group, 6 cases had moderate, 15 cases had minimum, 9 cases had no artifact. In the routine group, 8 cases minimum and 22 cases had no artifact. Image quality was significantly improved in the study group compared to the conventional group where X 2 =95.32 and P<0.01. CT value and the noise of the liver without artifact were (54.5 ± 3.0) HU and 10.7 ± 2.4 in the control group, (52.0 ± 3.5) HU and 10.7 ± 0.5 in the study group, (53.7 ± 3.1) HU and 9.9 ± 0.5 in the routine group, respectively. CT value and noise of the liver with artifact were (41.7 ± 8.4) HU and 17.9 ± 2.6 in control group, (53.1 ± 6.9) HU and 11.0 ± 0.7 in the study group, (54.1 ± 2.4) HU and 9.9 ± 0.5 in the routine group, respectively. The CT value and its noise variation with artifact were significantly higher in the control group than the study group and the control group, where F=36.352, 235.848, respectively and P<0.01. Conclusion: The image

  8. Osseous abnormalities and CT findings in stueve-wiedemann-syndrome (SWS); Ossaere Manifestationen und CT-Befunde bei der seltenen Skelettdysplasie Stueve-Wiedemann (SWS)

    Energy Technology Data Exchange (ETDEWEB)

    Langer, R. [UAE University, Dept. of Radiology, Al Ain (United Arab Emirates); Al-Gazali, L. [UAE University, Dept. of Paediatrics (United Arab Emirates); Haas, D. [FMHS - UAE Univ. and Tawam Hospital - Dept. of Radiology (United Arab Emirates); Raupp, P.; Varady, E. [Dept. of Paediatrics Al Ain (United Arab Emirates)

    2004-02-01

    -Wiedemann-Syndrom (SWS) werden anhand des eigenen Patientenkollektives analysiert. Methode: Bei 16 dysmorphen, kleinwuechsigen Neugeborenen wurden zur Klassifizierung der Dysplasie Thorax- und Skelettaufnahmen sowie in einem Fall erstmalig eine CT des Gesichtsschaedels durchgefuehrt. Die Diagnose eines SWS konnte nach Korrelation der klinischen und radiologischen Befunde frueh gestellt werden. Bei vier ueberlebenden Patienten erfolgten radiologische Verlaufskontrollen. Ergebnisse: Alle Neugeborene mit SWS wiesen Kleinwuchs, eine Mittelgesichtshypoplasie, verkruemmte lange Roehrenknochen mit Betonung der unteren Extremitaeten, dreieckige kortikale diaphysaere Sklerosen an den Konkavseiten der Verbiegungen und erweiterte Metaphysen mit abnormer Trabekelstruktur auf. Vier ueberlebende Patienten zeigten bei radiologischen Verlaufskontrollen progrediente Verkruemmungen der unteren Extremitaeten und zunehmende metaphysaere Entkalkungen. Schlussfolgerungen: Die Diagnose des seltenen SWS kann wegen der charakteristischen Roentgenveraenderungen bereits frueh postpartal gestellt werden. Hierzu ist eine gute Kooperation zwischen Radiologen, Klinikern und Genetikern erforderlich. Neben dem meist frueh letalen Verlauf gibt es auch selten Faelle, die die Neugeborenenperiode ueberleben. (orig.)

  9. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  10. WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

    International Nuclear Information System (INIS)

    Ritschl, L; Kachelriess, M; Kuntz, J

    2015-01-01

    Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging

  11. C-arm Cone Beam Computed Tomography: A New Tool in the Interventional Suite.

    Science.gov (United States)

    Raj, Santhosh; Irani, Farah Gillan; Tay, Kiang Hiong; Tan, Bien Soo

    2013-11-01

    C-arm Cone Beam CT (CBCT) is a technology that is being integrated into many of the newer angiography systems in the interventional suite. Due to its ability to provide cross sectional imaging, it has opened a myriad of opportunities for creating new clinical applications. We review the technical aspects, current reported clinical applications and potential benefits of this technology. Searches were made via PubMed using the string "CBCT", "Cone Beam CT", "Cone Beam Computed Tomography" and "C-arm Cone Beam Computed Tomography". All relevant articles in the results were reviewed. CBCT clinical applications have been reported in both vascular and non-vascular interventions. They encompass many aspects of a procedure including preprocedural planning, intraprocedural guidance and postprocedural assessment. As a result, they have allowed the interventionalist to be safer and more accurate in performing image guided procedures. There are however several technical limitations. The quality of images produced is not comparable to conventional computed tomography (CT). Radiation doses are also difficult to quantify when compared to CT and fluoroscopy. CBCT technology in the interventional suite has contributed significant benefits to the patient despite its current limitations. It is a tool that will evolve and potentially become an integral part of imaging guidance for intervention.

  12. The applications of 11C-MET PET in brain tumor

    International Nuclear Information System (INIS)

    Hua Fengchun

    2002-01-01

    11 C-methionine (MET), an amino acid, is the most widely used radio pharmaceutics which can reflect transport metabolism of amino acid in vivo, and synthesis of protein in tumor. 11 C-MET PET can be used for evaluation of brain tumor: detection of tumor, differential diagnosis between recurrence and radiation necrosis and early evaluation of response to treatment. Especially, for the definition of tumor margin and detection of low-grade tumors, PET with 11 C-MET is better than PET with 18 F-FDG or other modalities such as CT and MRI

  13. Utility of “1”1C -methionine PET/CT in neuro-oncology; Utilidad de “1”1C-metionina PET/CT en neurooncología

    Energy Technology Data Exchange (ETDEWEB)

    Casas Parera, I.; Igirio Gamero, J. L.; Báez, A.; Tafur Canabal, J. G.; Báez, M.; Kuchkaryan, V. [División Neurología, Instituto de Oncología Ángel H. Roffo, Facultad de Medicina, Universidad de Buenos Aires, Buenos Aires (Argentina); B lumenkrantz, Y.; Bruno, G., E-mail: neurooncoroffo@yahoo.com [Fundación Centro Diagnóstico Nuclear, Buenos Aires, Buenos Aires (Argentina)

    2013-07-01

    Positron emission tomography (PET) with “1”1C-methionine (“1”1C-methionine PET/CT) is a new technique used to evaluate primary central nervous system (CNS) tumors. We describe our experience regarding the first 4 patients with glial tumors and “1”1C-methionine PET/CT. This is a descriptive, observational and prospective study of 4 patients between 38-50 years of age, with different gliomas (WHO classification). MRI and “1”1C-methionine PET/CT were performed in all cases. Case 1, gliomatosis cerebri grade II post-radiotherapy. Case 2, oligodendroglioma grade II diagnosed and treated with radiotherapy in 1993. Case 3, glioblastoma grade IV post-radiotherapy + temozolomide. Case 4, anaplastic oligoastrocytoma grade III post-radiotherapy + temozolomide. The pattern of “1”1C-methionine uptake compared with MRI showed tumor progression in cases 1, 3 and 4, and in case 2 showed uptake although the final diagnosis was pseudoprogression. Unlike “1”8fluordeoxiglucose PET/TC, “1”1C-methionine uptake in normal brain tissue and pseudoprogression is low, and gliomas are displayed as metabolically active areas. The “1”1C-methionine PET/CT provided valuable information on the tumoral behavior and extension, although in one case presented did not differentiate tumor progression from pseudoprogression. “1”1C-methionine PET/CT could be a useful tool in the study and follow-up to patients with gliomas. (authors) [Spanish] La tomografía por emisión de positrones con metionina carbono 11 (“1”1C-metionina PET/TC) se utiliza en la evaluación de los tumores primarios del sistema nervioso central. Describimos nuestra expe¬riencia sobre los primeros 4 pacientes con tumores de la serie glial estudiados con “1”1C-metionina PET/TC. Este es un estudio descriptivo, observacional y prospectivo. Se presentan 4 pacientes entre 38-50 años de edad con diagnóstico de gliomas (clasificación de la OMS). A todos se les realizó RM y “1”1C

  14. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  15. CT and MRI of germ-cell tumors with metastasis or multi-located tumors

    International Nuclear Information System (INIS)

    Miyagami, Mitsusuke; Tazoe, Makoto; Tsubokawa, Takashi

    1989-01-01

    Twenty-seven cases of germ-cell tumors were examined with a CT scan in our clinic. In the 11 cases of metastasis or multi-localized tumors, the CT findings were studied in connection with the MRI findings. There were 6 cases of germ-cell tumors which had broad infiltrating tumors with multiple lesions on first admission. Their tumor sites were different from that in cases of malignant glioma, being frequently localized in the pineal and/or the suprasellar region, on the wall of the third and/or lateral ventricle, and in the region of the basal ganglia. Five of the cases of germ-cell tumors had metastasis with various patterns connected to a remote area - that is, to spinal cords, to the ventricular wall and basal cistern of the brain stem by CSF dissemination, to a lung by hematogeneous metastasis, and to the peritoneal wall or organs by a V-P shunt. The CT findings of germ-cell tumors were correlated mainly with the results of the histological diagnosis; they were found not to differ with the tumor site. The germinoma in the suprasellar region had less calcification than in the pineal region. Cysts, calcification, and an enlargement of the lateral ventricle on the tumor side were frequently seen in the germinoma of the basal ganglia. On the MRI of 5 cases of germinoma, the T 1 -weighted image revealed a slightly low or iso signal intensity, while the T 2 -weighted image showed a high signal intensity. In the case of multiple tumor lesions, some cases demonstrated different CT findings and radiosensitivities for each tumor. The possibility of a multicentric origin for the tumors is thus suggested in some cases of germ-cell tumors. (author)

  16. Diagnosis of pelvic wall tumor on multislice CT

    International Nuclear Information System (INIS)

    Zhang Keyun; Deng Lequn; Lei Hongwei

    2011-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) in diagnosing pelvic wall tumors. Methods: MSCT of 21 cases of pelvic wall tumors including metastasis (10), neurogenic tumor (5), chondrosarcoma (2), chordoma (1), aneurysmal bone cyst (1), giant cell tumor (1), and osteochondroma (1) was retrospectively analyzed. Results: CT appearances of pelvic wall tumors include bony destruction and soft tissue masses. Common features were bone destruction in metastasis, expansion of the neuroforamen in neurogenic tumor, pleomorphic calcification in chondrosarcoma, lower sacral vertebral location of chordoma, iliac crest bone destruction in giant cell tumor, cauliflower-like nodules in osteochondroma. Conclusion: MSCT with three-dimensional volume rendering demonstrates well the tumor shape, size, extent, internal structure and relationship with the surrounding organs to aid diagnosis of pelvic wall tumors. (authors)

  17. Arterial displacement by the tumor demonstrated by magnetic resonance CT

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Yoshikawa, Kohki; Machida, Tohru; Iio, Masahiro.

    1985-01-01

    MR-CT permits visualization of blood vessels non-invasively. Major blood vessels in scan slices are demonstrated as structures with low or no signal intensity. In this report, two cases with brain tumor and spinal tumor are presented in which arterial displacement by the tumor was visualized by MR-CT. MR-CT is considered to be an effective method in detecting blood vessel abnormalities. (author)

  18. Variability of Gross Tumor Volume in Nasopharyngeal Carcinoma Using 11C-Choline and 18F-FDG PET/CT.

    Directory of Open Access Journals (Sweden)

    Jun Jiang

    Full Text Available This study was conducted to evaluate the variability of gross tumor volume (GTV using 11C-Choline and 18F-FDG PET/CT images for nasopharyngeal carcinomas boundary definition. Assessment consisted of inter-observer and inter-modality variation analysis. Four radiation oncologists were invited to manually contour GTV by using PET/CT fusion obtained from a cohort of 12 patients with nasopharyngeal carcinoma (NPC and who underwent both 11C-Choline and 18F-FDG scans. Student's paired-sample t-test was performed for analyzing inter-observer and inter-modality variability. Semi-automatic segmentation methods, including thresholding and region growing, were also validated against the manual contouring of the two types of PET images. We observed no significant variation in the results obtained by different oncologists in terms of the same type of PET/CT volumes. Choline fusion volumes were significantly larger than the FDG volumes (p < 0.0001, mean ± SD = 18.21 ± 8.19. While significantly consistent results were obtained between the oncologists and the standard references in Choline volumes compared with those in FDG volumes (p = 0.0025. Simple semi-automatic delineation methods indicated that 11C-Choline PET images could provide better results than FDG volumes (p = 0.076, CI = [-0.29, 0.025]. 11C-Choline PET/CT may be more advantageous in GTV delineation for the radiotherapy of NPC than 18F-FDG. Phantom simulations and clinical trials should be conducted to prove the possible improvement of the treatment outcome.

  19. CT findings in acute small bowel diverticulitis; Computertomographie bei akuter Duenndarmdivertikulitis

    Energy Technology Data Exchange (ETDEWEB)

    Ferstl, F.J.; Obert, R. [Radiologisch-Nuklearmedizinisches Zentrum (RNZ) am St. Theresienkrankenhaus Nuernberg (Germany)

    2004-02-01

    radiologische Verfahren gesichert werden, wobei die CT die Methode der Wahl darstellt. Das vorwiegend in Form von Kasuistiken beschriebene Spektrum der CT-Morphologie der akuten Duenndarmdivertikulitis variiert je nach Ausmass des Entzuendungsprozesses. Als typische CT-Befunde finden sich ein entzuendetes Divertikel, peridivertikulaere Fettgewebsinfiltrationen, extraluminale Luftansammlungen als Zeichen einer gedeckten Perforation und ein Wandoedem des betroffenen Duenndarmsegmentes mit vermehrter Distanzierung der Darmschlingen. In sehr seltenen Faellen kann auch ein Enterolith in einem entzuendeten Divertikel nachweisbar sein. An Komplikationen koennen Abszesse, Fisteln, ein Ileus und eine freie Perforation mit Peritonitis auftreten. Diagnostische Probleme bereitet die Duenndarmdivertikulitis von allem bei Lokalisation im terminalen Ileum und im Meckel-Divertikel. Zur Sicherung der computertomographischen Verdachtsdiagnose einer akuten Duenndarmdivertikulitis koennen ein Enteroklysma bzw. beim Meckel-Divertikel eine 99m-Technetium-Pertechnetat-Szintigraphie eingesetzt werden. Wir beschreiben die CT-Befunde zweier Patientinnen mit akuter Jejunumdivertikulitis und eines Patienten mit Meckel-Divertikulitis und vergleichen die Ergebnisse mit den Angaben aus der Literatur. (orig.)

  20. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  1. Liver tumors, correlation of computed tomography (CT) and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1984-09-01

    Computed tomographic and pathologic correlation was studied in 12 autopsied cases with 11 cases of metastatic liver tumors and 1 case of hepatocellular carcinoma. Despite of proliferative patterns of the tumors, nodular low attenuations on CT showed scattered nodular lesions and geographic low attenuations on CT showed groups of multiple small nodular lesions, macroscopically. Abnormal areas of low attenuation were generally diminished by drip infusion contrast enhancement, which was more significant on tumors of infiltrative proliferation. Tumors of infiltrative proliferation revealed little degeneration of surrounding liver cells and abnormal areas of low attenuation were more distinct before contrast enhancement. Tumors of expansive proliferation revealed obvious degeneration of surrounding liver cells and a case having about 200 layers of degenerated liver cells revealed more distinct after contrast enhancement. The central lower density areas in abnormal areas of low attenuation on CT coincided with liquefactive necroses with scanty capillary. vessels and fibrotic changes, histopathologically. But coagulative necroses without decrease of surrouding blood flows were not visualized on CT. CT could not demonstrate the liquefactive necroses in more small nodules than 2 cm in diameter. (J.P.N.).

  2. Cystic tumors of the pancreas; Zystische Tumoren des Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Brambs, H.J.; Juchems, M. [Universitaetsklinikum Ulm, Abteilung fuer Diagnostische und Interventionelle Radiologie, Ulm (Germany)

    2008-08-15

    Cystic lesions of the pancreas encompass a broad spectrum of benign, premalignant, and malignant tumors which are primarily cystic or result from cystic necroses of solid neoplasms. Because of the wide use of cross-sectional imaging techniques they are increasingly being identified in asymptomatic patients as well as in patients presenting with abdominal pain, jaundice or pancreatitis. Among these lesions, intraductal papillary mucinous neoplasms, serous cystic neoplasms and mucinous cystic neoplasms represent the majority of cases. With increasing experience with these tumors, a refinement of our understanding of their morphology and of their natural course has emerged. It is important to be familiar with the CT and MR imaging features of these lesions to differentiate these tumors and to orient the diagnosis towards benign or malignant forms. Because characterization of cystic tumors of the pancreas can sometimes be difficult due to overlapping imaging features, additional criteria such as clinical symptoms, localization, age and gender have to be taken into account. If appropriately treated, these tumors can usually be cured by resection and the decreasing risk of pancreatic surgery has led to an increasing number of resections of pancreatic tumors. The management of cystic tumors of the pancreas has not yet been standardized and the correct evaluation and subsequent management of the disease in asymptomatic patients have not been fully defined. (orig.) [German] Zystische Pankreastumoren umfassen ein breites Spektrum gutartiger, praemaligner und maligner Veraenderungen, die primaer zystisch sind oder durch eine zystische Degeneration solider Tumoren entstehen. Wegen des breiten Einsatzes von Schnittbildtechniken werden sie zunehmend bei asymptomatischen Patienten und bei Patienten mit Bauchschmerzen, Pankreatitis und Ikterus entdeckt. Unter diesen Tumoren stellen die intraduktalen papillaeren muzinoesen Neoplasien, die seroesen zystischen Neoplasien und die

  3. Helical 3D-CT images of soft tissue tumors in the hand

    Energy Technology Data Exchange (ETDEWEB)

    Otani, Kazuhiro; Kikuchi, Hiraku; Tan, Akihiro; Hamanishi, Chiaki; Tanaka, Seisuke [Kinki Univ., Osaka-Sayama (Japan). School of Medicine

    2000-02-01

    X-ray, ultrasonograph CT, MRI and angiography are used to detect tumoral lesions. Recently, helical CT has been revealed to be a useful method for the diagnosis and preoperative evaluation of soft tissue tumors, by which high quality and accurate three dimensional (3D) images can be obtained quickly. We analyzed the preoperative 3D-CT images of soft tissue tumors in the hands of 11 cases (hemangioma in 6 cases, giant cell tumor, lipoma, angiofibroma, chondrosarcoma and malignant fibro-histiocytoma in one case each). Enhanced 3D-CT clearly visualized hemangiomas and solid tumors from the surrounding tissues. The tumors could easily be observed from any direction and color-coded according to the CT number. Helical 3D-CT was thus confirmed to be useful for the diagnosis and preoperative planning by indicating the details of tumor expansion into surrounding tissues. (author)

  4. The validity and findings of superselective angio-CT of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tomura, Noriaki; Kusaka, Kazuya; Kato, Koki; Sato, Kimihiko; Watarai, Jiro; Sasajima, Hiroyasu; Kowada, Masayoshi [Akita Univ. (Japan). School of Medicine; Hatayama, Takashi

    1995-09-01

    Superselective angio-CT (SSA-CT) was performed on 12 patients with malignant astrocytomas who had been treated with superselective intra-arterial infusions of ACNU. SSA-CT was done at the time of super-selective intra-arterial infusion. Following conventional intra-arterial DSA for which a 6-F catheter was used, a microcatheter (Tracker-18) was passed coaxially inside the guiding catheter, and advanced into the feeding arteries of the tumor. After the microcatheter was placed in the proper position, a dynamic CT was performed with contrast administration into the feeding arteries. A GE CT/T 9800 scanner was used; the contrast medium was iopamidol which was administered diluted with 5 volumes of saline. There was representation of tumor stains by SSA-CT in all 12 patients, and of the medullary veins in three. In contrast, DSA or conventional enhanced CT represented tumor stain/enhancement in only 10 patients, and the medullary veins in one. In two patients who had no contrast tumor enhancement on the CT with contrast, SSA-CT could represent tumor stain. SSA-CT was also superior to DSA and conventional CT for the visualization of medullary veins The feeding artery in a patient with a posterior frontal astrocytoma was unclear on DSA. However, SSA-CT with contrast administration in the anterior cerebral artery revealed tumor stain; this modality was also useful for identifying the artery to be used for ACNU infusion. In another patient with a tumor in the parahippocampal gyrus, SSA-CT with contrast administration in the posterior cerebral artery could provide the proper position of the catheter for the infusion of ACNU. None of the patients experienced complications due to catheterization nor any systemic side-effects. (H.O.).

  5. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  6. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  7. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  8. Analysis on CT features of tumor-like gastric schwannomas

    International Nuclear Information System (INIS)

    Zhang Yu; Chen Jie

    2011-01-01

    Objective: To analyze CT imaging features of tumor-like gastric schwannomas. Methods: Ten patients with gastric schwannomas were retrospectively analyzed. All were scanned with pre-and pro-enhanced CT. Analysis of the CT findings included evaluation of the volume, number, location, contour, growth pattern, border, enhancement pattern, and enhancement grade as well as the presence of surface dimpling, integrity of overlying mucosa. All cases were confirmed by pathology. Results: In every case, simple tumor was present. The largest was about 5.7 cm in the diameter, the smallest was 2.3 cm. All tumors were round or oval, and one tumor was slightly lobulated. Endoluminal growth pattern was defined in two cases, exoluminal growth pattern was defined in one case, and a mixed growth pattern was noted in the rest. The borders of tumors were clear. In arterial phase, no visible enhancement was present in eight cases and mild enhancement in two cases. All cases were constantly enhanced in portal phase. Superficial ulcers were present in four cases. Conclusion: CT findings of tumor-like gastric schwannomas are distinctive to a certain degree. It can be used to guide clinical therapy. (authors)

  9. TU-C-12A-11: Comparisons Between Cu-ATSM PET and DCE-CT Kinetic Parameters in Canine Sinonasal Tumors

    Energy Technology Data Exchange (ETDEWEB)

    La Fontaine, M; Bradshaw, T [University of Wisconsin, Madison, Wisconsin (United States); Kubicek, L [University of Florida, Gainesville, Florida (United States); Forrest, L [University of Wisconsin-Madison, Madison, Wisconsin (United States); Jeraj, R [University of Wisconsin, Madison, WI (United States)

    2014-06-15

    Purpose: Regions of poor perfusion within tumors may be associated with higher hypoxic levels. This study aimed to test this hypothesis by comparing measurements of hypoxia from Cu-ATSM PET to vasculature kinetic parameters from DCE-CT kinetic analysis. Methods: Ten canine patients with sinonasal tumors received one Cu-ATSM PET/CT scan and three DCE-CT scans prior to treatment. Cu-ATSM PET/CT and DCE-CT scans were registered and resampled to matching voxel dimensions. Kinetic analysis was performed on DCE-CT scans and for each patient, the resulting kinetic parameter values from the three DCE-CT scans were averaged together. Cu-ATSM SUVs were spatially correlated (r{sub spatial}) on a voxel-to-voxel basis against the following DCE-CT kinetic parameters: transit time (t{sub 1}), blood flow (F), vasculature fraction (v{sub 1}), and permeability (PS). In addition, whole-tumor comparisons were performed by correlating (r{sub ROI}) the mean Cu-ATSM SUV (SUV{sub mean}) with median kinetic parameter values. Results: The spatial correlations (r{sub spatial}) were poor and ranged from -0.04 to 0.21 for all kinetic parameters. These low spatial correlations may be due to high variability in the DCE-CT kinetic parameter voxel values between scans. In our hypothesis, t{sub 1} was expected to have a positive correlation, while F was expected to have a negative correlation to hypoxia. However, in wholetumor analysis the opposite was found for both t{sub 1} (r{sub ROI} = -0.25) and F (r{sub ROI} = 0.56). PS and v{sub 1} may depict angiogenic responses to hypoxia and found positive correlations to Cu-ATSM SUV for PS (r{sub ROI} = 0.41), and v{sub 1} (r{sub ROI} = 0.57). Conclusion: Low spatial correlations were found between Cu-ATSM uptake and DCE-CT vasculature parameters, implying that poor perfusion is not associated with higher hypoxic regions. Across patients, the most hypoxic tumors tended to have higher blood flow values, which is contrary to our initial hypothesis. Funding

  10. Non-tumor enhancement at the surgical margin on CT after the removal of brain tumors

    International Nuclear Information System (INIS)

    Adachi, Michito; Hosoya, Takaaki; Yamaguchi, Kohichi; Yamada, Kiyotada

    1992-01-01

    Marginal enhancement is occasionally seen at the surgical margin on CT after the total removal of brain tumors. This enhancement disappears in due time, and therefore we call it non-tumor enhancement. It is often difficult, however, to differentiate non-tumor enhancement from tumor recurrence. In this study, we attempted to determine the characteristics of non-tumor enhancement. The subjects of the study consisted of 15 patients with astrocytoma and one with metastatic tumor in whom sequential CT scans had been performed after total removal of the tumor. Based on the observation of these sequential CT scans, the characteristics of non-tumor enhancement were presumed to be as follows: (1) In four cases, enhancement at the surgical margin persisted more than four months after surgery and then disappeared. Therefore, these cases were considered non-tumor enhancement. Prolonged duration of enhancement such as that in these cases is not necessarily due to recurrence. Marginal enhancement within 3 mm in thickness and with a well-demarcated border like that of a flax is likely to be non-tumor enhancement. (author)

  11. CT-guided stereotaxic implantation of Ommaya reservoir for cystic brain tumor

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Nobukazu; Niizuma, Hiroshi; Johkura, Hidefumi; Katoh, Seiya; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-02-01

    We report the use of CT-guided stereotaxic system to implant Ommaya reservoir in 26 patients with cystic brain tumors consisting of 16 gliomas, 3 craniopharyngiomas, 3 metastatic brain tumors and 5 other and unknown pathologies, on the way of their biopsy. The entire procedure was carried out in the CT room using Leksell's CT stereotaxic system. In 24 cases with supratentorial tumors, it was at the option of the operator to take any approach such as frontal, posterior temporal and parietal approaches. Especially in 3 cases of craniopharyngioma, we inserted the tube into their cyst directly so that the ventricle should not be open to the cyst. Also in cases of a pontine glioma and a C-P angle metastatic tumor, we used retromastoid approach to the posterior fossa by making patient's heads turned about 30 to 40 deg to contralateral side of the approach, with slight flexion of the neck. Minimal bleeding occurred during operation in one case, however, it showed no clinical symptoms. Advantages of this method are as follows: Operative invasion is minimal; The surgeon can check the course of the cannula and position of the tip of Ommaya tube even at operation, and can modify it, if necessary.

  12. CT-guided stereotaxic implantation of Ommaya reservoir for cystic brain tumor

    International Nuclear Information System (INIS)

    Nakasato, Nobukazu; Niizuma, Hiroshi; Johkura, Hidefumi; Katoh, Seiya; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    We report the use of CT-guided stereotaxic system to implant Ommaya reservoir in 26 patients with cystic brain tumors consisting of 16 gliomas, 3 craniopharyngiomas, 3 metastatic brain tumors and 5 other and unknown pathologies, on the way of their biopsy. The entire procedure was carried out in the CT room using Leksell's CT stereotaxic system. In 24 cases with supratentorial tumors, it was at the option of the operator to take any approach such as frontal, posterior temporal and parietal approaches. Especially in 3 cases of craniopharyngioma, we inserted the tube into their cyst directly so that the ventricle should not be open to the cyst. Also in cases of a pontine glioma and a C-P angle metastatic tumor, we used retromastoid approach to the posterior fossa by making patient's heads turned about 30 to 40 deg to contralateral side of the approach, with slight flexion of the neck. Minimal bleeding occurred during operation in one case, however, it showed no clinical symptoms. Advantages of this method are as follows: Operative invasion is minimal; The surgeon can check the course of the cannula and position of the tip of Ommaya tube even at operation, and can modify it, if necessary. (author)

  13. Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery

    International Nuclear Information System (INIS)

    Siewerdsen, J.H.; Moseley, D.J.; Burch, S.; Bisland, S.K.; Bogaards, A.; Wilson, B.C.; Jaffray, D.A.

    2005-01-01

    A mobile isocentric C-arm (Siemens PowerMobil) has been modified in our laboratory to include a large area flat-panel detector (in place of the x-ray image intensifier), providing multi-mode fluoroscopy and cone-beam computed tomography (CT) imaging capability. This platform represents a promising technology for minimally invasive, image-guided surgical procedures where precision in the placement of interventional tools with respect to bony and soft-tissue structures is critical. The image quality and performance in surgical guidance was investigated in pre-clinical evaluation in image-guided spinal surgery. The control, acquisition, and reconstruction system are described. The reproducibility of geometric calibration, essential to achieving high three-dimensional (3D) image quality, is tested over extended time scales (7 months) and across a broad range in C-arm angulation (up to 45 deg.), quantifying the effect of improper calibration on spatial resolution, soft-tissue visibility, and image artifacts. Phantom studies were performed to investigate the precision of 3D localization (viz., fiber optic probes within a vertebral body) and effect of lateral projection truncation (limited field of view) on soft-tissue detectability in image reconstructions. Pre-clinical investigation was undertaken in a specific spinal procedure (photodynamic therapy of spinal metastases) in five animal subjects (pigs). In each procedure, placement of fiber optic catheters in two vertebrae (L1 and L2) was guided by fluoroscopy and cone-beam CT. Experience across five procedures is reported, focusing on 3D image quality, the effects of respiratory motion, limited field of view, reconstruction filter, and imaging dose. Overall, the intraoperative cone-beam CT images were sufficient for guidance of needles and catheters with respect to bony anatomy and improved surgical performance and confidence through 3D visualization and verification of transpedicular trajectories and tool placement

  14. CT findings of skull tumors forming subcutaneous masses

    International Nuclear Information System (INIS)

    Niida, Hirohito; Takeda, Norio; Onda, Kiyoshi; Tanaka, Ryuichi

    1991-01-01

    Some characteristics of CT findings in 27 patients with skull tumors forming subcutaneous tumors were studied. There were sixteen metastatic skull tumors, six primary skull tumors, and five meningiomas. A CT scan was found to be helpful in the diagnosis of the lesions. Especially, bone-window CT images proved very sensitive in the detection of destructive and permeative lesions of the skull. In 19 of the 27 cases, some lytic lesions were observed. In all cases with skull metastasis from carcinomas, a complete osteolytic change of the skull was observed. Furthermore, all of the metastatic tumors from thyroid carcinoma showed well circumscribed and homogeneously enhanced lesions, in contrast with the other metastatic carcinomas, which usually showed heterogeneously enhanced lesions with irregular margins. Osteoblastic changes were characteristically observed in all cases of meningiomas, osteosarcoma, and chondrosarcoma. Meningiomas were located mainly in the intracranial region and extended extracranially. In one case of malignant lymphoma, one of a neuroblastoma, and one of leukemia, there was little or no gross cortical bone change, despite a large mass. (author)

  15. The application of PET-CT in gastrointestinal stromal tumor

    International Nuclear Information System (INIS)

    Xian Weijun; Feng Yanlin

    2009-01-01

    Gastrointestinal stromal tumor (GIST) is a mesenchymal neoplasm of uncertain malignant potential that arises predominantly in the gastrointestinal tract. Due to lack of specific physical signs, imagin g-x examination is an important auxiliary means in diagnosing gastrointestinal stromal tumor. Compared to other conventional imaging examinations, PET-CT has demonstrated unique superiority in staging, response evaluation and follow-up of gastrointestinal stromal tumor. And now it presents an overview of the application valuation of PET-CT and related imaging technology in gastrointestinal stromal tumor as follow. (authors)

  16. CT findings of malignant nasal cavity tumors

    International Nuclear Information System (INIS)

    Ku, Young Mi; Chun, Kyung Ah; Choi, Kyu Ho; Yu, Won Jong; Kim, Young Joo; Kim, Sung Hoon; Park, Seog Hee; Shinn, Kyung Sub

    1997-01-01

    To evaluate the CT findings of malignant nasal cavity tumors. Retrospective analysis was performed on 20 patients with pathologically-proven malignant nasal cavity tumors. Using CT, we analysed their location, extent of bone destruction and of involvement of adjacent structures, and enhancing pattern. A total of 20 cases included nine squamous cell carcinomas, three olfactory neuroblastomas, three lymphomas, two polymorphic reticulosis, one adenoid cystic carcinoma, one undifferentiated carcinoma and one metastasis from renal cell carcinoma. All cases except one adenoid cystic carcinoma and one squamous cell carcinoma revealed bone destruction or erosion. Aggressive bone destruction and irregular enhancement were seen in eight cases of squamous cell carcinoma, seven cases of which showed involvement of the adjacent paranasal sinuses, nasopharynx, and orbit. Olfactory neuroblastomas were centered in the superior nasal cavity and the adjacent ethmoid sinus, and erosion or destruction of the cribriform plate had occurred. Lymphomas showed bilateral involvement, with uniform contrast enhancement. Polymorphic reticuloses showed perforation or erosion of the nasal septum, with bilateral involvement of the nasal cavity. The location, presence of bone destruction, involvement of adjacent structures, and enhancement pattern of tumor on CT can be helpful for the differential diagnosis of malignant nasal cavity tumors

  17. Sacroiliitis in children with spondyloarthropathy: therapeutic effect of CT-guided intra-articular corticosteroid injection; Sakroiliitis bei Kinder mit Spondylarthropathie: Therapeutischer Effekt der CT-gestuetzten intraartikulaeren Kortikosteroid-Injektionen

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T.; Hermann, K.G.A.; Diekmann, F.; Hamm, B. [Humboldt-Universitaet, Berlin (Germany). Universitaetsklinikum Charite, Inst. fuer Radiologie; Biedermann, T. [HELIOS Klinikum Berlin (Germany). II. Klinik fuer Kinderheilkunde und Jugendmedizin, Abt. Kinderrheumatologie; Braun, J. [Rheumazentrum Ruhrgebiet, St. Josefs-Krankenhaus (Germany); Bollow, M. [Augusta-Krankenhaus, Bochum (Germany). Inst. fuer Radiologie

    2003-06-01

    . The follow-up dynamic MRI (0.1 mmol/kg body weight) during therapy showed a statistically significant lower contrast-enhancement in both groups (group 1: 117{+-}43% versus 38{+-}24%, p<0.05; group 2: 127{+-}59% versus 38{+-}22%, p<0.05). One third of the patients of group 2 showed progression of joint destruction despite absence of subjective complaints. (orig.) [German] Ziel: Prospektive Pruefung des therapeutischen Effektes der CT-gesteuerten intraartikulaeren Kortikosteroid-Injektion entzuendlicher Sakroiliakalgelenke (SIG) bei Kindern mit juveniler Spondylarthropathie (jSpA) im Vergleich zur konventionellen Therapie mit nichtsteroidalen Antirheumatika (NSAR) sowie Bestimmung der Wertigkeit der Magnetresonanztomographie (MRT) bei der Indikationsstellung und der Therapieverlaufskontrolle. Material und Methode: Bei 89 Kindern mit bekannter jSpA wurden mittels dynamischer MRT uni- oder bilaterale Sakroiliitiden diagnostiziert. Bei allen 89 Patienten wurde daraufhin eine Therapie mit NSAR eingeleitet bzw. bereits bestehende Therapien fortgesetzt. Vier Wochen nach der diagnostischen MRT wurden zwei Gruppen definiert: 33 Patienten mit klinischem Response auf NSAR (Gruppe 1) und 56 Nonresponder (Gruppe 2). Die Patienten der Gruppe 2 wurden unter Belassung der NSAR zusaetzlich einer CT-gestuetzten (Low-Dose-Technik) intraartikulaeren Kortikosteroid-Injektion zugefuehrt, wobei insgesamt 83 SIG punktiert und infiltriert wurden (27 bilateral, 29 unilateral). Die Indikationsstellung zur Intervention beruhte auf der zuvor MR-tomographisch gesicherten Entzuendungsaktivitaet. Klinische Therapieverlaufskontrollen erfolgten in 8- bis 12-woechigen Intervallen ueber einen Zeitraum von 20 Monaten. MRT-Verlaufskontrollen wurden bei allen 56 Kindern der Gruppe 2 und bei 15 von 33 Kindern der Gruppe 1 in einem Zeitraum von 8{+-}4 Monaten nach der Erstuntersuchung durchgefuehrt. Ergebnisse: Ingesamt 87,5% der komplikationslos punktierten Kinder der Gruppe 2 (Standardtherapie

  18. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  19. Molecular imaging of head and neck cancers. Perspectives of PET/MRI; Molekulare Bildgebung bei Kopf-ï]¿Hals-Tumoren. Perspektive der PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Stumpp, P.; Kahn, T. [Universitaetsklinikum Leipzig AoeR, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Purz, S.; Sabri, O. [Universitaetsklinikum Leipzig, Klinik und Poliklinik fuer Nuklearmedizin, Leipzig (Germany)

    2016-07-15

    The {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG-PET/CT) procedure is a cornerstone in the diagnostics of head and neck cancers. Several years ago PET-magnetic resonance imaging (PET/MRI) also became available as an alternative hybrid multimodal imaging method. Does PET/MRI have advantages over PET/CT in the diagnostics of head and neck cancers ?The diagnostic accuracy of the standard imaging methods CT, MRI and PET/CT is depicted according to currently available meta-analyses and studies concerning the use of PET/MRI for these indications are summarized. In all studies published up to now PET/MRI did not show superiority regarding the diagnostic accuracy in head and neck cancers; however, there is some evidence that in the future PET/MRI can contribute to tumor characterization and possibly be used to predict tumor response to therapy with the use of multiparametric imaging. Currently, {sup 18}F-FDG-PET/CT is not outperformed by PET/MRI in the diagnostics of head and neck cancers. The additive value of PET/MRI due to the use of multiparametric imaging needs to be investigated in future research. (orig.) [German] Die {sup 18}F-Fluordesoxyglukose-Positronenemissionstomographie-Computertomographie ({sup 18}F-FDG-PET-CT) hat ihren festen Stellenwert in der Diagnostik von Kopf-Hals-Tumoren. Seit einigen Jahren ist die PET-MRT als weitere hybride Bildgebungsmodalitaet verfuegbar. Bringt die PET-MRT Fortschritte bei der Diagnostik von Kopf-Hals-Tumoren ?Darstellung der diagnostischen Genauigkeit der bisherigen Bildgebungsmethoden CT, MRT und PET-CT anhand von Metaanalysen und Zusammenfassung der bisherigen Publikationen zur PET-MRT auf diesem Gebiet. Die PET-MRT zeigt in allen bisherigen Studien keine Ueberlegenheit bzgl. der diagnostischen Genauigkeit von Kopf-Hals-Tumoren. Sie kann jedoch durch die multiparametrische Diagnostik perspektivisch Beitraege zur Tumorcharakterisierung und damit moeglicherweise Voraussagen zum

  20. CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model.

    Science.gov (United States)

    Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2007-06-01

    To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible

  1. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Higashihara, Hiroki; Osuga, Keigo; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Hori, Masatoshi; Kim, Tonsok; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2012-04-15

    This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. (orig.)

  2. Prognostic value of tumor necrosis at CT in diffuse large B-cell lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com [Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht (Netherlands); Klerk, John M.H. de [Department of Nuclear Medicine, Meander Medical Center, Amersfoort (Netherlands); Fijnheer, Rob [Department of Hematology, Meander Medical Center, Amersfoort (Netherlands); Dubois, Stefan V. [Department of Pathology, Meander Medical Center, Amersfoort (Netherlands); Nievelstein, Rutger A.J.; Kwee, Thomas C. [Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht (Netherlands)

    2015-03-15

    Highlights: •CT is compulsory for staging newly diagnosed DLBCL. •Approximately 13.7% of DLBCL patients have tumor necrosis at CT. •Tumor necrosis status at CT is not associated with any NCCN-IPI factor. •Patients with tumor necrosis at CT have a significantly worse outcome. -- Abstract: Objective: To determine the prognostic value of tumor necrosis at computed tomography (CT) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Materials and methods: This retrospective study included 51 patients with newly diagnosed DLBCL who had undergone both unenhanced and intravenous contrast-enhanced CT before R-CHOP (rituximab, cyclophosphamide, hydroxydaunorubicin, oncovin and prednisolone) chemo-immunotherapy. Presence of tumor necrosis was visually and quantitatively assessed at CT. Associations between tumor necrosis status at CT and the National Comprehensive Cancer Network (NCCN) International Prognostic Index (IPI) factors were assessed. Cox regression analysis was used to determine the prognostic impact of NCCN-IPI scores and tumor necrosis status at CT. Results: There were no correlations between tumor necrosis status at CT and the NCCN-IPI factors categorized age (ρ = −0.042, P = 0.765), categorized lactate dehydrogenase (LDH) ratio (ρ = 0.201, P = 0.156), extranodal disease in major organs (φ = −0.245, P = 0.083), Ann Arbor stage III/IV disease (φ = −0.208, P = 0.141), and Eastern Cooperative Oncology Group (ECOG) performance status (φ = 0.015, P = 0.914). In the multivariate Cox proportional hazards model, only tumor necrosis status at CT was an independent predictive factor of progression-free survival (P = 0.003) and overall survival (P = 0.004). Conclusion: The findings of this study indicate the prognostic potential of tumor necrosis at CT in newly diagnosed DLBCL.

  3. Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Zhikui Wei

    2015-06-01

    Full Text Available The accurate and efficient localization of underlying vascular lesions is crucial for prompt and definitive treatment of subarachnoid hemorrhage (SAH. To demonstrate the utility and feasibility of intraoperative C-arm angiography in cerebrovascular emergencies, we report five cases of high grade SAH and/or intracerebral hemorrhage (ICH where intraoperative diagnostic C-arm angiography was safely and effectively utilized. Initial evaluations of all patients included a non-contrast head CT scan, which was followed by urgent decompressive hemicraniectomy as a life-saving measure in the presence of markedly elevated intracranial pressure. Further diagnostic evaluations were performed intraoperatively using a multi-purpose C-arm angiography system. The C-arm angiography findings greatly aided the intraoperative planning and led to definitive treatments in four cases of SAH by elucidating the underlying neurovascular lesions. With this treatment strategy, two of the patients made moderately good recoveries from their SAH and/or ICH with a Glasgow outcome score (GOS of 4. Three of the patients expired despite maximal therapy mostly due to unfavorable presenting grade. These results suggest that C-arm angiography is a reasonable diagnostic and surgical planning tool for selected patients with high grade diffuse SAH who require immediate decompression.

  4. Value of PET and PET-CT for monitoring tumor therapy

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2007-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) PET or PET-CT is an accurate test for differentiating residual viable tumor tissue from therapy-induced changes in tumor. Furthermore, quantitative assessment of therapy-induced changes in tumor 18 F-FDG uptake may allow the prediction of tumor response. Treatment may be adjusted according to tumor response. So it is increasingly used to monitor tumor response in patients undergoing chemotherapy and chemoradiotherapy. Here we focused on practical aspects of 18 F-FDG PET or PET-CT for treatment monitoring and on the existing advantages and challenges. (authors)

  5. Computed tomography of liver tumors, 2. Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor by dynamic CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Akira; Fukuoka, Haruhito; Kashiwado, Kouzou; Ichiki, Toshio; Makidono, Yoko [Hiroshima Red Cross Hospital (Japan)

    1984-02-01

    Differential diagnosis between hepatocellular carcinoma and metastatic hepatic tumor was attempted using dynamic CT scanning. Homogeneous and patchy types were peculiar to hepatocellular carcinoma, and ring-like type to metastatic hepatic tumor. However, with no enhancement, hepatocellular carcinoma could not be denied. Hepatocellular carcinoma was characterized by the enhancement shown on the early stage of dynamic CT. Ring enhancement was not visualized on dynamic CT but visualized on conventional contrast enhanced CT in hepatocellular carcinomas; it was visualized on conventional contrast enhanced CT and on dynamic CT in metastatic hepatic tumors.

  6. Tumor Radiation Therapy Creates Therapeutic Vaccine Responses to the Colorectal Cancer Antigen GUCY2C

    Energy Technology Data Exchange (ETDEWEB)

    Witek, Matthew [Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Blomain, Erik S.; Magee, Michael S.; Xiang, Bo; Waldman, Scott A. [Department of Pharmacology and Experimental Therapeutics, Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Snook, Adam E., E-mail: adam.snook@jefferson.edu [Department of Pharmacology and Experimental Therapeutics, Thomas Jefferson University, Philadelphia, Pennsylvania (United States)

    2014-04-01

    Purpose: Radiation therapy (RT) is thought to produce clinical responses in cancer patients, not only through direct toxicity to cancer cells and supporting tumor stroma cells, but also through activation of immunologic effectors. More recently, RT has potentiated the local and systemic effects of cancer immunotherapy (IT). However, combination regimens that maximize immunologic and clinical efficacy remain undefined. Methods and Materials: We evaluated the impact of local RT on adenoviral-mediated vaccination against the colorectal cancer antigen GUCY2C (Ad5-GUCY2C) in a murine subcutaneous tumor model using mouse CT26 colon cancer cells (CT26-GUCY2C). Immune responses were assessed by ELISpot, and clinical responses were assessed by tumor size and incidence. Results: The specific sequence of tumor-directed RT preceding Ad5-GUCY2C IT transformed inactive therapeutic Ad5-GUCY2C vaccination into a curative vaccine. GUCY2C-specific T cell responses were amplified (P<.05), tumor eradication was maximized (P<.01), and tumor volumes were minimized (P<.001) in mice whose tumors were irradiated before, compared with after, Ad5-GUCY2C vaccination. The immunologic and antitumor efficacy of Ad5-GUCY2C was amplified comparably by unfractionated (8 Gy × 1), or biologically equivalent doses of fractionated (3.5 Gy × 3), RT. The antitumor effects of sequential RT and IT (RT-IT) depended on expression of GUCY2C by tumor cells and the adenoviral vaccine vector, and tumor volumes were inversely related to the magnitude of GUCY2C-specific T cell responses. Moreover, mice cured of CT26-GUCY2C tumors by RT-IT showed long-lasting antigen-dependent protection, resisting tumors formed by GUCY2C-expressing 4T1 breast cancer cells inoculated 50 days after CT26 cells. Conclusions: Optimal sequencing of RT and IT amplifies antigen-specific local and systemic immune responses, revealing novel acute and long-term therapeutic antitumor protection. These observations underscore the importance

  7. CT and MR imaging of primary tumors of the masticator space

    International Nuclear Information System (INIS)

    Aspestrand, F.; Boysen, M.

    1992-01-01

    A retrospective study of CT and MR examinations in 14 patients with benign and malignant tumors originating in the masticator space is presented. At presentation, 12 patients revealed tumor extension to adjacent regions and spaces. Perineutral tumor spread along trigeminal nerve branches to the cavernous sinus and orbits was combined with facial pain, and/or numbness, ophthalmoplegia, and exophthalmus. Detailed analysis of tumor growth and spread, enhancement and signal features at CT and MR imaging indicated that tumor histology was, with a few exceptions, nonspecific. More extensive growth and bone destruction was noted only among malignant tumors. MR imaging was found superior to CT in delineating tumor extension due to better soft tissue contrast resolution and multiplanar imaging. Posttreatment examinations were available in 11 patients and showed long-standing regional edema of the adjacent temporal lobe and masticator muscles in 4 out of 5 patients without clinical evidence of tumor. In 6 patients, CT and MR features were found almost unchanged with only small size differences after various forms of treatment. (orig.)

  8. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Herausforderung dar. Ziel dieser Arbeit war die Ermittlung der diagnostischen Genauigkeit der Dual-energy-CT-Angiographie (DE-CTA) im Vergleich zum Goldstandard, der invasiven digitalen Subtraktionsangiographie (DSA) bei der Stenoseerkennung, da die DE-CTA potenziell eine Differenzierung von Verkalkungen und jodhaltigem Kontrastmittel ermoeglicht. Dreissig Patienten mit dem Verdacht auf das Vorliegen oder bekannter PAVK und zusaetzlich bestehendem Diabetes mellitus wurden retrospektiv in die Studie eingeschlossen. Bei allen Teilnehmern wurde eine DE-CTA (Somatom Definition Flash, Siemens Healthcare, Germany), gefolgt von einer invasiven Angiographie durchgefuehrt. Das Vorhandensein von Stenosen in gekruemmten multiplanaren Reformationen (MPR) und Projektionen maximaler Intensitaet (MIP) wurde verblindet evaluiert. Die diagnostische Genauigkeit wurde mit der Angiographie als Goldstandard errechnet. Bei den 30 in die Analyse eingeschlossenen diabetischen Patienten (83 % maennlich, 70,0 ± 10,5 Jahre alt, 83 % Diabetes mellitus Typ 2) war die Praevalenz behandlungsbeduerftiger Stenosen in 331 evaluierten Gefaesssegmenten hoch (30 %). Die DE-CTA detektierte kritische Stenosen mit einer hohen Sensitivitaet und guten Spezifitaet anhand gekruemmter MPR (100 und 93,1 %) und MIP (99 und 91,8 %). In einer Subanalyse war die diagnostische Genauigkeit am hoechsten fuer Stenosen im Bereich der Beckenstrombahn (gekruemmte MPR 97,1 % vs. MIP 100 %) und im Oberschenkelbereich (99,2 vs. 96,6 %) verglichen mit dem Unterschenkelkompartiment (90,9 vs. 88 %). Die DE-CTA weist eine hohe diagnostische Genauigkeit bei der Stenosenerkennung und -charakterisierung im Rahmen der PAVK bei Patienten mit Diabetes mellitus auf, hat jedoch eine eingeschraenkte Genauigkeit im Bereich des Unterschenkelkompartiments. (orig.)

  9. Diagnosis of intracranial mixed tumor with CT and MRI (report of 7 cases)

    International Nuclear Information System (INIS)

    Guan Changqun; Zhou Huaiwei; Xue Hongli; Zhang Yuzhong; Hu Lianyuan

    1998-01-01

    Purpose: To recognize the images of intracranial mixed tumor. Materials and methods: Seven cases were studied with CT and MRI. All were proved by pathology, including mixed tumor of meningioma with glioblastoma 2 cases, meningioma with pituitary tumor 2 cases, glioblastoma multiform with angioblastoma 1 cases, cholesteatoma with melanoma 1 case, and pituitary tumor with meningioma 1 case. The authors analysed the CT and MRI manifestations of intracranial mixed tumor retrospectively. Results: The CT and MRI manifestations of intracranial mixed tumor were exactly like meningioma, glioma, and hypophysoma, etc, therefore it was usually misdiagnosed the common tumor. Four cases intracranial mixed tumor displayed two kinds of characteristic CT and MRI manifestation on the same region of the same tumor in contrast with the clinic and pathologic change. Conclusion: There were no characteristic CT and MRI manifestations; the diagnosis should be made in combination with clinical information

  10. Ranking of CT in persistent vertigo after implantation of stapes prostheses; Stellenwert der Computertomographie bei persistierenden Gleichgewichtsstoerungen nach dem Einsatz von Stapesplastiken

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, S. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Woldag, K. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Meister, E.F. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Reschke, I. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Schulz, H.G. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [Deutsch] Von 150 Patienten zeigten 10 nach dem Einsatz einer Stapesprothese eine persistierende vestibulaere Symptomatik. Mittels der hochaufloesenden Felsenbein-CT in axialer und koronarer Schnittfuehrung konnten in allen Faellen in Symptomatik erklaerende Befunde erhoben werden. Eine operative Bestaetigung erfolgte in 9 Faellen. Als bisher in der Literatur in diesem Zusammenhang nicht beschriebenes, indirektes Zeichen einer Perilymphfistel wurde eine kleine Luftblase am Prothesenende nachgewiesen. Die HR-CT hat sich als wesentliche Erleichterung bei der Planung einer Retympanotomie erwiesen. (orig.)

  11. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  12. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Cohen, D.; Bruckheimer, E.; Bachar, G. N.; Konstantinovsky, R.; Birk, E.; Atar, E.

    2016-01-01

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  13. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A. [Soreq NRC, Radiation Protection Domain (Israel); Cohen, D.; Bruckheimer, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Bachar, G. N.; Konstantinovsky, R. [Rabin Medical Center, Department of Diagnostic Radiology (Israel); Birk, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Atar, E., E-mail: elia@clalit.org.il [Rabin Medical Center, Department of Diagnostic Radiology (Israel)

    2016-05-15

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  14. Marker detection evaluation by phantom and cadaver experiments for C-arm pose estimation pattern

    Science.gov (United States)

    Steger, Teena; Hoßbach, Martin; Wesarg, Stefan

    2013-03-01

    C-arm fluoroscopy is used for guidance during several clinical exams, e.g. in bronchoscopy to locate the bronchoscope inside the airways. Unfortunately, these images provide only 2D information. However, if the C-arm pose is known, it can be used to overlay the intrainterventional fluoroscopy images with 3D visualizations of airways, acquired from preinterventional CT images. Thus, the physician's view is enhanced and localization of the instrument at the correct position inside the bronchial tree is facilitated. We present a novel method for C-arm pose estimation introducing a marker-based pattern, which is placed on the patient table. The steel markers form a pattern, allowing to deduce the C-arm pose by use of the projective invariant cross-ratio. Simulations show that the C-arm pose estimation is reliable and accurate for translations inside an imaging area of 30 cm x 50 cm and rotations up to 30°. Mean error values are 0.33 mm in 3D space and 0.48 px in the 2D imaging plane. First tests on C-arm images resulted in similarly compelling accuracy values and high reliability in an imaging area of 30 cm x 42.5 cm. Even in the presence of interfering structures, tested both with anatomy phantoms and a turkey cadaver, high success rates over 90% and fully satisfying execution times below 4 sec for 1024 px × 1024 px images could be achieved.

  15. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  16. Computed tomography (CT) of the parapharyngeal space tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kuriyama, K.; Narumi, Y.; Fujita, M.; Sato, T.; Kajita, A.; Sakai, Y.; Tanaka, H.; Nakanishi, K.; Fujino, Y.

    1987-04-01

    The parapharyngeal space is of great clinical importance. Because of its location deep within the neck, this space is difficult to be examined by ordinary methods but can be well demonstrated by CT. Ten patients with parapharyngeal space tumors were examined with CT. They consisted of 3 pleomorphic adenomas, 1 myoepitherioma, 1 metastatic lymphadenopathy, 1 branchial cleft cyst, 2 schwannomas, 1 neurofibroma and 1 branchiogenic carcinoma respectively. Parapharyngeal space is divided into parapharyngeal space (prestyloid space), carotid space (retrostyloid space), and retropharyngeal space. It is important to determine localization and mapping of parapharyngeal tumors, because the characteristic tumor types in histologic terms are found in each subdivision of parapharyngeal space.

  17. TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions

    International Nuclear Information System (INIS)

    Fahrig, R.

    2015-01-01

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions

  18. TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions

    Energy Technology Data Exchange (ETDEWEB)

    Fahrig, R. [Stanford University (United States)

    2015-06-15

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions

  19. SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

    International Nuclear Information System (INIS)

    Liu, H; Gao, Y; Xu, X; Zhuo, W; Wu, J

    2015-01-01

    Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulation (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)

  20. Brain tumors and CT scans in infants and children, (3)

    International Nuclear Information System (INIS)

    Oi, Shizuo

    1983-01-01

    In clinical pictures of brain tumors in infants and children, many features are not identical to those in adults, including characteristics of the tumors in age population, the locations of the tumors, the clinical symptoms and signs, and various factors affecting prognosis. We have, therefore, clinically and extensively analyzed brain tumors in infants and children. This study was also performed in order to analyze the characteristic CT findings of astrocytoma, the tumor most frequently occurring among infants and children. The subjects were 24 cases of astrocytoma and 2 cases of glioblastoma in infants and children under 16 years. The locations and characteristics of the tumors were as follows. Most of the tumors occurred in the 4th ventricle, had a characteristic low density, and could almost entirely be clearly distinguished from medulloblastomas, but not from ependymomas, on CT. The features of the supratentorial tumors were similar to those of the astrocytomas and glioblastomas mostly appearing in adults, as previously reported, in the relatively close correlation with the location and malignancy of the tumor. There was also a case of diffuse astrocytoma, a ''non-enhanced low-density solid tumor,'' which raised clinical problems. Among low-grade astrocytomas in infants and children, only a few show a high density on plain CT, many have, at least macroscopically, a strong contrast enhancement, and peritumoral edema is not observed on CT or, if observed, is observed only slightly. As individual features, homogenous enhancement pattern, a mixed density, a central low density, and a rare absence of enhancement are listed. (author)

  1. CT differentiation of infiltrating renal cell carcinoma and renal urothelial tumor

    International Nuclear Information System (INIS)

    Choi, Hyo Kyeong; Goo, Dong Erk; Bang, Sun Woo; Lee, Moon Gyu; Cho, Kyoung Sik; Auh, Yong Ho

    1994-01-01

    It may be difficult to differentiate renal cell carcinoma involving collecting system from renal urothelial tumor invading into renal parenchyma. The purpose of this study was to assess the differences of CT findings between two conditions. CT findings of 5 cases of renal cell carcinoma involving the renal collecting systems and 10 cases of renal urothelial tumors invading the renal parenchyma were compared, and analyzed about the presence or absence of hydronephrosis, normal or abnormal CT nephrogram, renal contour changes due to mass and tentative diagnosis. The diagnoses were confirmed at surgery. Renal cell carcinoma showed hydronephrosis in only 20% and normal CT nephrogram and outward contour bulging in all cases. In contrast, renal urothelial tumor showed hydronephrosis(70%), abnormal CT nephrogram(60%), and preservation of reinform shape(100%). Renal contour changes and CT nephrogram may be useful in distinguishing both disease entities

  2. Study on the application of PET-CT in gynecology tumors

    International Nuclear Information System (INIS)

    Wen Lilian

    2012-01-01

    Gynecology tumors seriously threatened the health of female. With the development of imageology, PET, a functionality examination method, has been widely used in the early diagnosis and monitoring of curative effect in gynecology tumors. PET-CT has the good future in its development because it combined with the advantage of functional and structural imaging. The characters and application of PET-CT in gynecology tumors were reviewed in this paper. (author)

  3. Radiation dose reduction and new image modalities development for interventional C-arm imaging system

    Science.gov (United States)

    Niu, Kai

    Cardiovascular disease and stroke are the leading health problems and causes of death in the US. Due to the minimally invasive nature of the evolution of image guided techniques, interventional radiological procedures are becoming more common and are preferred in treating many cardiovascular diseases and strokes. In addition, with the recent advances in hardware and device technology, the speed and efficacy of interventional treatment has significantly improved. This implies that more image modalities can be developed based on the current C-arm system and patients treated in interventional suites can potentially experience better health outcomes. However, during the treatment patients are irradiated with substantial amounts of ionizing radiation with a high dose rate (digital subtraction angiography (DSA) with 3muGy/frame and 3D cone beam CT image with 0.36muGy/frame for a Siemens Artis Zee biplane system) and/or a long irradiation time (a roadmapping image sequence can be as long as one hour during aneurysm embolization). As a result, the patient entrance dose is extremely high. Despite the fact that the radiation dose is already substantial, image quality is not always satisfactory. By default a temporal average is used in roadmapping images to overcome poor image quality, but this technique can result in motion blurred images. Therefore, reducing radiation dose while maintaining or even improving the image quality is an important area for continued research. This thesis is focused on improving the clinical applications of C-arm cone beam CT systems in two ways: (1) Improve the performance of current image modalities on the C-arm system. (2) Develop new image modalities based on the current system. To be more specific, the objectives are to reduce radiation dose for current modalities (e.g., DSA, fluoroscopy, roadmapping, and cone beam CT) and enable cone beam CT perfusion and time resolved cone beam CT angiography that can be used to diagnose and triage acute

  4. Warthin's Tumor of the Parotid Gland: CT and MR Features

    International Nuclear Information System (INIS)

    Lee, Yun Hee; Yu, In Kyu; Lee, Byung Hee; Kim, Min Sun; Han, Moon Hee; Song, Chang Joon

    2009-01-01

    In this study, we have evaluated the imaging features of Warthin's tumor of the parotid gland with the use of CT and MR imaging. CT (n = 30) and MR (n = 7) images of 26 patients (M:F=23:3; age range, 38-76 years; mean age, 58 years) with surgically-proven Warthin's tumor (n = 37) were reviewed with a focus on bilaterality, multiplicity, location, size, demarcation, margin, enhancement pattern and MR signal intensity. Lesions were bilateral in seven patients (27%), multiple in nine patients (35%) and unilateral multiple in four patients (15%). Tumors were located in the superficial lobe (65%), deep lobe (24%) and both lobes (11%) of the parotid gland. Most tumors had a clear (95%) and smooth margin (95%) with a round or oval shape. Tumors mainly showed a solid and cystic composition (n = 24, 65%) and all solid stroma showed poor or weak enhancement on both CT and MR images. Papillary projections from the peripheral wall were clearly seen (n = 6, 86%). Warthin's tumor is frequently seen in the parotid superficial lobe of older males with a higher bilateral and multiple tendency. Warthin's tumor shows cystic portions with papillary projections at the wall on CT images and focal high signal intensity (SI) on T1-weighted images with dense nodular enhancement on MR images

  5. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  6. Diagnosis of pancreatic tumors by spiral angio CT

    International Nuclear Information System (INIS)

    Miura, Kohi; Nakao, Norio; Takayasu, Yukio; Okawa, Tomohisa

    1995-01-01

    Spiral angio were performed with injection of 30 ml of contrast material at a rate of 1 ml/sec with a scan delay of 6 sec through catheter into the celiac artery while the blood flow of the superior mesenteric artery (SMA) was occluded by the inflated balloon catheter. Spiral CT scans were obtained using Somatom Plus (Siemens). Parameter for spiral CT were 24-sec acquisition time, 5 mm collimation, 5 mm/sec table incrementation. Reconstructions were performed every 5 mm. Pancreatic cancers were characteristically depicted with spiral angio CT as hypodensity relative to normal enhanced pancreatic parenchyma. On dynamic angio CT studies performed in pancreatic cancers, the area of cancer and normal parenchyma had maximum level of enhancement at 10-15 sec after injection of contrast material via catheter into the celiac, and there was no difference in enhancement between tumor and normal parenchyma. On the other hand, the lesions of cancer were revealed as hypodensity with spiral angio CT. In case of chronic pancreatitis, the enhancement of the entire pancreas obtained with spiral angio CT was homogeneous. Insulinoma in the tail of pancreas was detected by spiral angio CT but was not detected by both selective angiography and conventional CT. Three-dimensional (3-D) rendering spiral angio CT data shows the extent of vascular involvement by pancreatic cancer and provides useful information for surgical planning. Spiral angio CT is the most useful procedure for diagnosis of pancreatic tumor. (author)

  7. MO-DE-207A-06: ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Slagowski, JM; Dunkerley, DAP [MA Speidel, University of Wisconsin - Madison, Madison, WI (United States)

    2016-06-15

    Purpose: To obtain ECG-gated CT images from truncated projection data acquired with a C-arm based inverse geometry fluoroscopy system, for the purpose of cardiac chamber mapping in interventional procedures. Methods: Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system with a scanned multisource x-ray tube and a photon-counting detector mounted to a C-arm. In the proposed method, SBDX short-scan rotational acquisition is performed followed by inverse geometry CT (IGCT) reconstruction and segmentation of contrast-enhanced objects. The prior image constrained compressed sensing (PICCS) framework was adapted for IGCT reconstruction to mitigate artifacts arising from data truncation and angular undersampling due to cardiac gating. The performance of the reconstruction algorithm was evaluated in numerical simulations of truncated and non-truncated thorax phantoms containing a dynamic ellipsoid to represent a moving cardiac chamber. The eccentricity of the ellipsoid was varied at frequencies from 1–1.5 Hz. Projection data were retrospectively sorted into 13 cardiac phases. Each phase was reconstructed using IGCT-PICCS, with a nongated gridded FBP (gFBP) prior image. Surface accuracy was determined using Dice similarity coefficient and a histogram of the point distances between the segmented surface and ground truth surface. Results: The gated IGCT-PICCS algorithm improved surface accuracy and reduced streaking and truncation artifacts when compared to nongated gFBP. For the non-truncated thorax with 1.25 Hz motion, 99% of segmented surface points were within 0.3 mm of the 15 mm diameter ground truth ellipse, versus 1.0 mm for gFBP. For the truncated thorax phantom with a 40 mm diameter ellipse, IGCT-PICCS surface accuracy measured 0.3 mm versus 7.8 mm for gFBP. Dice similarity coefficient was 0.99–1.00 (IGCT-PICCS) versus 0.63–0.75 (gFBP) for intensity-based segmentation thresholds ranging from 25–75% maximum contrast. Conclusions: The

  8. The role of CT in the diagnosis of tumors in sellar area

    International Nuclear Information System (INIS)

    Li Wenxin

    2005-01-01

    Objective: To evaluate computed tomography (CT) in patients with tumors in sellar area. Methods: CT images of 33 patients with sellar area tumor's proved by surgery and pathology were analyzed retrospectively. Results: Pituitary adenomas (n=20), craniopharyngiomas (n=8) and meningiomas (n=3) had characteristic findings and were given a high rate of correct diagnosis. While astrocytoma (n=1) and germinoma (n=1) were solid lesions in sellar area and lack of diagnostic signs and the astrocytoma was misdiagnosed as craniopharyngioma. Conclusion: CT, especially 2-demision reconstructed (coronal and sagittal) images can demonstrate inner structure, pattern of growth, extension of invasion of tumors as well as the relationship between tumor and the adjacent vessels. CT plays an important role in the diagnosis of tumors in seliar area. (authors)

  9. Metastatic liver tumor from cystic ovarian carcinomas. CT and MRI appearance

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi; Yamashita, Yasuyuki; Ogata, Ichiro; Namimoto, Tomohiro; Abe, Yasuko; Urata, Joji; Takahashi, Mutsumasa [Kumamoto Univ. (Japan). School of Medicine

    1999-08-01

    The initial and follow-up CT and MRI images of ten patients with hepatic metastases from ovarian tumors were retrospectively analyzed to establish their features and sequential changes in appearance. Ten patients with hepatic metastasis from ovarian tumors received initial and follow-up CT and MRI examinations. Six patients were followed up every two to three weeks before surgical tumor resection. Both CT and MR images were analyzed by two radiologists. A total of fourteen lesions were detected by CT and MRI in 10 patients. All 14 lesions were demonstrated as areas of marked hyperintensity on T2-weighted MRI. Eleven cyst-like tumors were demonstrated as round or oval low density lesions on CT and as areas of hypointensity on T1-weighted imaging. Three lesions were shown as solid masses with slightly low attenuation at the initial CT examination and slightly low or iso-intensity areas on T1-weighted imaging, and these lesions showed early peripheral globular enhancement and delayed enhancement on contrast-enhanced CT and MR imaging. Cystic formation was observed two to three weeks later after initial study in all the 3 solid lesions. Rapid subcapsular effusion, which showed obvious enhancement on delayed Gd-DTPA enhanced MR imaging, was observed in two patients. The hepatic metastatic tumor from cystic ovarian carcinoma may manifest as a well-defined cystic lesion or as a solid mass, and the solid mass shows delayed enhancement on contrast-enhanced CT and MR imaging. Furthermore, rapid cystic formation and rapid subcapsular extension is frequently seen. (author)

  10. Pulmonary manifestations in collagen vascular diseases; Pulmonale Manifestationen bei Kollagenosen

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, M.N.A. [Thoraxklinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kreuter, M. [Thoraxklinik, Universitaetsklinikum Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kauczor, H.U. [Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Heussel, C.P. [Thoraxklinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany); Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany)

    2016-10-15

    Pulmonary complications are frequent in patients with collagen vascular diseases (CVD). Frequent causes are a direct manifestation of the underlying disease, side effects of specific medications and lung infections. The standard radiological procedure for the work-up of pulmonary pathologies in patients with CVD is multidetector computed tomography (MDCT) with thin-slice high-resolution reconstruction. The accuracy of thin-slice CT for the identification of particular disease patterns is very high. The pattern of usual interstitial pneumonia (UIP) representing the direct pulmonary manifestation of rheumatoid arthritis (RA) can be identified with a sensitivity of 45 % and a specificity of 96 %. Both direct pulmonary manifestations, drug-induced toxicity and certain infections can have a similar appearance in thin-slice MDCT in various forms of CVD. Knowledge of the patterns and causes contributes to the diagnostic certainty. At first diagnosis of a CVD and associated pulmonary symptoms thin-slice MDCT is recommended. Clinical, lung function and imaging follow-up examinations should be performed every 6-12 months depending on the results of the MDCT. In every case the individual CT morphological patterns of pulmonary involvement must be identified. The combination of information on the anamnesis, clinical and imaging results is a prerequisite for an appropriate disease management. (orig.) [German] Pulmonale Komplikationen sind bei Patienten mit Kollagenosen keine Seltenheit. Haeufig sind eine direkte Manifestation der Grunderkrankung, eine Nebenwirkung der medikamentoesen Therapie oder eine Lungeninfektion die Ursachen. Das radiologische Standardverfahren zur Klaerung pulmonaler Pathologien bei Patienten mit Kollagenosen ist die Multidetektorcomputertomographie mit duennschichtigen Rekonstruktionen (Duennschicht-MDCT). Die Treffsicherheit der Duennschicht-MDCT ist fuer die Identifikation eines Erkrankungsmusters sehr hoch. So kann beispielsweise das Muster einer

  11. The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu [Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota (United States); Brinkmann, Debra H.; Ward, Shelly B. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Durski, Jolanta [Department of Radiology, Nuclear Medicine Program, Mayo Clinic, Rochester, Minnesota (United States); Laack, Nadia N.; Yan, Elizabeth; Schomberg, Paula J.; Garces, Yolanda I. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Suman, Vera J. [Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States); Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2013-03-15

    Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.

  12. The addition of SPECT/CT lymphoscintigraphy to breast cancer radiation planning spares lymph nodes critical for arm drainage.

    Science.gov (United States)

    Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A

    2013-03-15

    This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav; Dietrich, Tobias J.; Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo; Le Corroller, Thomas

    2017-01-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  14. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Dietrich, Tobias J. [Balgrist University Hospital, Department of Radiology, Zurich (Switzerland); Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo [Siemens Healthcare GmbH, Business Area Advanced Therapies, Forchheim (Germany); Le Corroller, Thomas [Aix-Marseille Universite, CNRS, ISM UMR 7287, Marseille (France); Radiology Department, APHM, Marseille (France)

    2017-02-15

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  15. Role of respiratory-gated PET/CT for pancreatic tumors: A preliminary result

    International Nuclear Information System (INIS)

    Kasuya, Takeo; Tateishi, Ukihide; Suzuki, Kazufumi; Daisaki, Hiromitsu; Nishiyama, Yuji; Hata, Masaharu; Inoue, Tomio

    2013-01-01

    Purpose: The aim of this study is to ascertain role of respiratory-gated PET/CT for accurate diagnosis of pancreatic tumors. Materials and methods: Prior to clinical study, the phantom study was performed to evaluate the impact of respiratory motion on lesion quantification. Twenty-two patients (mean age 65 years) with pancreatic tumors were enrolled. Pathological diagnoses by surgical specimens consisted of pancreatic cancer (n = 15) and benign intraductal papillary mucinous neoplasm (IPMN, n = 7). Whole-body scan of non-respiratory-gated PET/CT was performed at first, and subsequent respiratory-gated PET/CT for one bed position was performed. All PET/CT studies were performed prior to surgery. The SUV max obtained by non-respiratory-gated PET/CT and respiratory-gated PET/CT, and percent difference in SUVmax (%SUVmax) were compared. Results: The profile curve of 5 respiratory bin image was most similar to that of static image. The third bin of 5 respiratory bin image showed highest FWHM (24.0 mm) and FWTM (32.7 mm). The mean SUVmax of pancreatic cancer was similar to that of benign IPMN on non-respiratory-gated PET/CT (p = 0.05), whereas significant difference was found between two groups on respiratory-gated PET/CT (p = 0.016). The mean %SUV of pancreatic cancer was greater than that of benign IPMN (p < 0.0001). Identification of the primary tumor in pancreatic head (n = 13, 59%) was improved by using respiratory-gated PET/CT because of minimal affection of physiological accumulation in duodenum. Conclusion: Respiratory-gated PET/CT is a feasible technique for evaluation of pancreatic tumors and allows more accurate identification of pancreatic tumors compared with non-respiratory-gated PET/CT

  16. Magnetic resonance tomography in eclampsia; Magetresonanztomographie bei Eklampsie

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, U. [St.-Vincentius-Krankenhaeuser, Karlsruhe (Germany). Radiologische Klinik

    1995-05-01

    Eclampsia is a rare but severe complication during the course of a pregnancy. The CT-findings at the brain are well known. Reports on MRT-findings are limited, however, especially in German literature. We describe the MRT picture of the cerebral changes caused by eclampsia and discuss the advantages of MRT in comparison with CT. The use of contrast agents with MRT shows breakdown of blood-brain barrier but does not provide any information of therapeutical consequences and should be avoided during pregnancy. An early and targeted use of MRT in any case of unclear or suspicious neurological symptoms during pregnancy is recommended. MRT supports differential diagnosis regarding non pregnancy-related cerebral disease and can be helpful for therapy planning in cases of preeclampsia. Additionally, MRT offers the possibility to control the effect of therapy with regard to brain damage. (orig.) [Deutsch] Die Eklampsie ist eine seltene aber erhebliche Komplikation im Verlauf einer Schwangerschaft. Die computertomographischen Veraenderungen im Gehirn sind bekannt. Mitteilungen von kernspintomographischen Befunden finden sich vor allem in der deutschen Literatur noch selten. Wir beschreiben das kernspintomographische Bild der zerebralen Veraenderungen bei Eklampsie und diskutieren die Vorteile der MRT im Vergleich zur CT. Die Gabe von Kontrastmittel bei der MRT weist zwar die Blut-Hirn-Schrankenstoerung nach, bringt aber keine therapeutisch relevanten Informationen. Sie sollte waehrend der Schwangerschaft vermieden werden. Ein frueher und gezielter Einsatz der MRT bei unklaren oder verdaechtigen neurologischen Symptomen waehrend der Schwangerschaft ist sinnvoll. Die MRT unterstuetzt die Differentialdiagnose in bezug auf nicht schwangerschaftsbezogene zerebrale Leiden und kann fuer die Therapie richtungweisend sein, wenn die Gestose noch nicht ausgepraegt ist. (orig.)

  17. Mediastinal Hodgkin lymphomas in computertomography: exact CT-based volume assessment and approximations with simple geometric models; Mediastinale Hodgkin-Lymphone in der Computertomographie. Vergleich von exakter CT-gestuetzter Volumetrie und Volumenabschaetzung mit Hilfe einfacher geometrischer Modelle

    Energy Technology Data Exchange (ETDEWEB)

    Battmann, A. [Marburg Univ. (Germany). Abt. fuer Strahlendiagnostik; Dieckmann, K.; Resch, A.; Poetter, R. [Allgemeines Krankenhaus, Wien (Austria). Universitaetsklinik Strahlentherapie und Strahlenbiologie; Battmann, A. [Giessen Univ. (Germany). Zentrum fuer Pathologie

    2001-03-01

    ; results in the closest approximation compared to the true volume. In the course of clinical studies it might be helpful to apply this formula to determine the prognostic relevance of the tumor size and its development under therapy. (orig.) [German] Hintergrund: Ziel dieser Arbeit waren die Bestimmung eines moeglichst exakten Modells zur Abschaetzung der Volumina von Lymphommanifestationen im Vergleich zu computertomographisch bestimmten Tumorvolumina und eine Abschaetzung der zu erwartenden Fehlerbreite. Material und Methoden: Es wurden 30 CT-Untersuchungen mediastinaler Tumoren von an Morbus Hodgkin erkrankten Kindern fuer die Untersuchung herangezogen. Die CT-Aufnahmen wurden mittels einer an einen Framegrabber angeschlossenen CCD-Videokamera digitalisiert. Mit Hilfe der GLOBAL-LAB-Image-Software wurde die Tumormasse unter Ausschluss nicht tumorzugehoeriger Binnenstrukturen ermittelt. Im Anschluss wurden die Volumina einfacher geometrischer Figuren (Quader, Ellipsoid, Oktaeder) aus den Maximalausmessungen der Tumoren errechnet. Abschliessend erfolgte die Berechnung der Abweichung der Volumina der geometrischen Modelle von dem durch das Computerprogramm ermittelten echten Tumorvolumen. Ergebnisse: Das Volumenmodell 'Quader' ueberschaetzte das Tumorvolumen um 89 bis 268%. Das Volumenmodell 'Ellipsoid' ueberschaetzte die Tumorgroesse im Mittel um 29%. Das Modell 'Oktaeder' unterschaetzte die Tumorgroesse im Mittel um 18%. Eine Division des Quadervolumens durch 2,3 approximierte das geometrische am naechsten an das Realvolumen: Im Mittel wurde das Tumorvolumen bei Tumoren, deren Volumen 20 ml ueberschritt, um 2% ueberschaetzt. Eine suffiziente Abschaetzung von Tumoren, deren Volumen weniger als 20 ml betrug, war weder mittels dieser noch mit den uebrigen Approximationen moeglich. Schlussfolgerungen: Fuer die Bestimmung von Tumorvolumina bei mediastinalen Hodgkin-Lymphomen ab 20 ml Volumen bietet die Formel Quader /2,3 die bestmoegliche

  18. CT and MRI findings of 4th ventricular tumors

    International Nuclear Information System (INIS)

    Kim, Taek Geun; Ro, Hee Jeong; Byun, Jae Young; Lee, Han Jin; Chung, Myung Hee; Choi, Kyu Ho; Shinn, Kyung Sub

    1994-01-01

    The purpose of our study is to evaluate characteristic features of 4th ventricular tumors in CT and MRI. Pathologically proved 9 patients with 4th ventricular tumor were examined by CT and/or MRI. 4th ventricular tumors were ependymoma(4 cases), medulloblastoma(2 case), choroid plexus papilloma(2 cases), and oligodendroglioma(1 cases). Include in our study were only those mass lesions that were located at surgery predominantly within 4th ventricle with or without ventricular expansion. The origin of 4th ventricular tumor was the roof (ependymoma 3 cases, medulloblastoma 2 cases), the floor (ependymoma 1 cases), and the undetermined(remaining 3 case). On MRI, all tumors were hypointense except ependymoma (3 cases) showing isointensity on T1WI. All tumors were hypointense on PDWI and T2WI. On Gd-DTPA enhanced T1WI, strong enhancement was seen in all but ependymoma(1 cases) which showed mild enhancement. On CT, as compared with MR images, various density on precontrast and postcontrast images were seen. Calcification was seen in choroid plexus papilloma(1 caes) and oligodendroglioma(1 cases). Hydrocephalus is seen in all cases except ependymoma(2 cases) and oligodendroglioma(1 case). Hemorrhage within tumor was present only in ependymoma(2 cases). Cystic change or necrosis of tumor was seen in ependymoma(3 cases), choroid plexus papilloma(1 case), and oligodendroglioma(1 case). Peritumoral edema was seen in medulloblastoma(1 case). Extension through the foramen Luschka and the Megendie was seen in ependymoma (2 cases), choroid plexus(2 cases), and medulloblastoma (1 case). Seeing along the CSF pathway was seen only in ependymoma(2 case). The results od our study may suggest that specific diagnosis of 4th ventricular tumor can be suggested preoperatively by analysing the origin in 4th ventricle, difference of CT density or MRI signal intensity, presence of extension or seeding through cerebrospinal fluid of the lesion

  19. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris, E-mail: boris.schell@googlemail.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Heidenreich, Ralf, E-mail: ralf.heidenreich@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Heidenreich, Monika, E-mail: info@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Thalhammer, Axel, E-mail: axel.thalhammer@kgu.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Naeem, Naguib Nagy Naguib, E-mail: nagynnn@yahoo.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas Josef, E-mail: T.Vogl@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Zangos, Stefan, E-mail: Zangos@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany)

    2012-12-15

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  20. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    Science.gov (United States)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    International Nuclear Information System (INIS)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-01-01

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  2. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    International Nuclear Information System (INIS)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo

    1997-01-01

    The purpose of this study was 1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and 2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20

  3. TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

    International Nuclear Information System (INIS)

    Chen, G.

    2015-01-01

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions

  4. TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G. [University of Wisconsin (United States)

    2015-06-15

    This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions

  5. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  6. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  7. Clinical relevance of F-18 FDG PET for imaging of neuroendocrine tumors; Wertigkeit der F-18-FDG-PET bei neuroendokrinen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. [Klinikum der Ruhr-Univ. Bochum - Marienhospital, Herne (Germany). Klinik fuer Radiologie und Nuklearmedizin; Baum, R.P. [Zentralklinik Bad Berka (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Hoer, G. [Frankfurt Univ., Frankfurt am Main (Germany). Klinik fuer Nuklearmedizin

    2001-04-01

    Neuroendocrine tumors are characterized immunocytochemically by the expression of different peptides and biogenic amines. Hormones induce their biological action by binding to and stimulating specific membrane-associated receptors for e.g. somatostatin. The presence of somatostatin receptors (SR) has been described mainly in endocrine glands and the central nervous system. Interestingly, a large variety of human tumors, including gastroenteropancreatic (GEP) tumors and medullary thyroid carcinomas (MTC) also express a high density of SR and can be imaged with [{sup 111}In-DTPA-D-Phe{sup 1}]-pentetreotide. Cell proliferative activity is an important indicator of the growth of various malignant tumors associated with a poorer prognosis and Ki-67 expression. {sup 18}F-FDG is a marker of tumor viability, based upon the increased glycolysis that is associated with malignancy as compared with normal tissue. SR-containing neuroendocrine tumors are well-differentiated and tend to grow slowly. Furthermore, these tumors demonstrate inverse relationship between in vivo SR expression, cell proliferation (low Ki-67 expression) and FDG uptake (normal biodistribution). In comparison, less differentiated tumors, e.g. atypical carcinoids or MTC with increasing CEA levels show mitotic activity (high levels of Ki-67 immunoreactivity and increased FDG uptake) and often lack of SR. In conclusion, SR scintigraphy has been shown to localize well-differentiated neuroendocrine tumors. In contrast, PET imaging is valuable for predicting malignancy only in less differentiated tumors with incresed glucose metabolism. Therefore, an additional F-18 FDG PET should be performed if SR scintigraphy (GEP tumors) or combined imaging using [{sup 111}In-DTPA-D-Phe{sup 1}]-pentetreotide and {sup 99m}Tc(V)-DMSA (MTC) is negative. (orig.) [German] Neuroendokrine Tumoren werden durch die spezifische Produktion von Polypeptidhormonen und biogenen Aminen klassifiziert. Die Informationsuebertragung der

  8. Comparison of the sensitivity and specificity of CT and MR imaging in the detection of cervical nodal tumor necrosis and extracapsular tumor spread

    International Nuclear Information System (INIS)

    Yousem, D.M.; Som, P.M.; Schjwaibold, F.; Hendrix, R.

    1991-01-01

    This paper evaluates if MR imaging can achieve the sensitivity and specificity of enhanced CT in detecting tumoral nodal necrosis (TNN) and extracapsular tumor spread (ETS). Enhanced CT scans and unenhanced and enhanced MR images were retrospectively and separately reviewed by a study-blinded radiologist. Fifty-eight lymph nodes were evaluated for TNN and ETS. Readings were given for CT, T1-weighted MR, T2-weighted MR, T1-weighted and T2-weighted MR, enhanced T1-weighted fat-suppressed MR, and T1-weighted, T2-weighted, and enhanced fat suppressed T1-weighted MR. Pathology proof was used to assess TNN; CT and used to assess ETS. Enhanced CT had the highest sensitivity for TNN. The sensitivity of unenhanced MR ranged from 33% to 50%; that of enhanced MR was 47%. All MR sequences and cT had specificities for TNN >92%. The highest accuracy of MR for TNN was the unenhanced T1-weighted and T2-weighted images alone; CT accuracy was 90%. MR sensitivity for ETS was maximal with T1-weighted images; all sequences had specificities >90%. Gadolinium-enhanced images did not improve accuracy in TNN or ETS

  9. Preclinical imaging in animal models of radiation therapy; Praeklinische Bildgebung im Tiermodell bei Strahlentherapie

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, K.; Cyran, C.C.; Reiser, M.F.; Clevert, D.-A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Lauber, K. [Klinikum der Ludwig-Maximilians-Universitaet, Klinik und Poliklinik fuer Strahlentherapie, Muenchen (Germany)

    2012-03-15

    -funktionelle Informationen ueber den Tumor zur Verfuegung gestellt werden. Die dynamische kontrastmittelverstaerkte MRT-, CT- oder ultraschallbasierte Perfusionsbildgebung sowie Hybridverfahren wie PET/CT oder MRT/PET haben das Potenzial, vitale und/oder perfundierte Tumoranteile zu identifizieren und abzugrenzen, um so eine gezielte Strahlentherapie zu optimieren. Ziel ist eine genauere Abgrenzung und Behandlung des Tumors bei gleichzeitiger Reduzierung der Dosis und Schonung des umliegenden gesunden Gewebes. In der Entwicklung neuer bildgebender Methoden fuer die Planung einer individualisierten Strahlentherapie kommt der praeklinischen, wissenschaftlichen Bildgebung und Forschung eine besondere Rolle zu, da nur in einem praeklinischen Setting, also in tierexperimentellen Tumormodellen, die Moeglichkeiten einer multimodalen Bildgebung ausreichend genau evaluiert und weiterentwickelt werden koennen. Neue funktionelle bildgebende Methoden werden fuer die Ueberwachung einer fruehen Therapieantwort (''early response'') unter Strahlentherapie oder fuer die Darstellung der Wertigkeit neuer Kombinationstherapien (z. B. Antiangiogenese plus Strahlentherapie) eine zunehmende Rolle spielen. (orig.)

  10. Neuroendocrine tumors of the pancreas; Multimodale Bildgebung bei neuroendokrinen Tumoren des Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Holzapfel, Konstantin; Rummeny, Ernst J. [Technische Univ. Muenchen (Germany). Inst. fuer Radiologie; Gaertner, Florian C. [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik

    2011-12-15

    Neuroendocrine tumors (NET) of the pancreas are rare entities. Functioning tumors tend to present early with specific symptoms and typical abnormalities in laboratory values. In contrast, non-functioning NET are often diagnosed with delay and become evident by tumor-related symptoms like pain, weight-loss or jaundice. The role of imaging is to localize and delineate the primary tumor and to detect metastases. In the diagnosis of NET radiologic techniques like computed tomography (CT) and magnetic resonance imaging (MRI) are applied. In certain cases nuclear medicine techniques like somatostatin receptor scintigraphy (SRS) and positron emission tomography (PET) using radioactively labelled somatostatin analogues are used. The present article reviews characteristic imaging findings of both functioning and non-functioning NET of the pancreas. (orig.)

  11. The accuracy of CT and tumor markers in the detection of a recurrent ovarian carcinoma

    International Nuclear Information System (INIS)

    Wakabayashi, Yukari; Ishida, Jiro; Kotake, Fumio; Hirose, Masahiro; Kawana, Koji; Abe, Kimihiko; Amino, Saburo; Negishi, Yoshiyuki; Akiya, Kiyoshi

    1989-01-01

    Twenty-three patients previously diagnosed as having ovarian cancer were examined with both serum tumor markers (CA 125, CA 19-9, TPA, IAP, AFP) and a pelvic CT scan. The tumor markers predict the clinical outcome more accurately than the CT scan. Further, the tumor markers showed a clear correlation with the clinical course. But in one case, however, the tumor markers were seen to reduce below the normal level from chemotherapy, while the CT scan showed a tumor mass. Thus, both, a CT scan and tumor marker assays are felt to be indispensable for detecting the recurrence of an ovarian cancer. (author)

  12. BEI Resource Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — BEI Resources provides reagents, tools and information for studying Category A, B, and C priority pathogens, emerging infectious disease agents, non-pathogenic...

  13. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  14. CT differentiation of solid ovarian tumor and uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Rae; Cho, Kyoung Sik [Asan Medical Center, Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Sohn, Chul Ho [Dongsan Medical Center, Keimyung Univ. College of Medicine, Taegu (Korea, Republic of); Ji, Eun Kyung [Bombit Hospital, Seoul (Korea, Republic of)

    1999-06-01

    On the basis of CT findings, to differentiate between solid ovarian tumor and uterine subserosal myoma. In eight surgically proven cases of solid ovarian tumor and in ten uterine subserosal myoma patients, contrast-enhanced CT images were obtained. Two genitourinary radiologists reviewed the findings with regard to degree of enhancement of the mass as compared with enhancement of uterine myometrium, thickening of round ligaments, visualization of normal ovaries, contour of the mass, and the presence of ascites in the pelvic cavity. Six of eight ovarian tumors but only two of ten uterine myomas were less enhanced than normal uterine myometrium (p<0.05). Pelvic ascites were seen in six of eight ovarian tumors, but in only one of ten uterine myomas (P<0.05). Three of 16 ovaries in ovarian tumor patients, but 12 of 20 ovaries in uterine myoma patients, were normal (p<0.05). Six of 16 round ligaments of the uterus in ovarian tumor patients, were thichened but 11 of 20 round ligaments in uterine myoma patients, were thickened (p>0.05). The contour of the mass was lobulated in two of eight ovarian tumor patients, but in five of ten uterine myoma patients (p>0.05). CT findings suggestive of solid ovarian tumor were less contrast enhancement of the mass than of normal uterine myometrium, pelvic ascites, and nonvisualization of normal ovary.

  15. Supratentorial primary intra-axial tumors in children. MR and CT evaluation

    International Nuclear Information System (INIS)

    Higano, S.; Takahashi, S.; Kurihara, N.; Singh, L.N.; Yamada, S.; Ishii, K.; Matsumoto, K.; Shirane, R.; Katakura, R.

    1997-01-01

    Purpose: To evaluate the MR and CT features of pediatric supratentorial intra-axial tumors with respect to different diagnosis and the role of each investigation modality. Material and Methods: MR and CT findings in 40 children with 12 types of pathologically proven histological tumors were reviewed. Results: The location of tumors might be one clue to differential diagnosis. In our material, cysts (60%), calcifications (45%), and intratumoral hemorrhages (27%) were found in the tumors. Characteristic features noted in some lesions included: peritumoral hemosiderin deposition in cavernous angiomas; intratumoral flow void in a choroid plexus carcinoma and in glioblastomas; and hemicerebral atrophy in germinomas. A comparison between malignant and benign tumors showed perifocal edema and a mass effect to be signifcantly more common in malignant lesions. Homogeneous enhancement suggested a benign tumor and an inhomogeneous pattern represented malignancy, while the lack of obvious enhancement did not always suggest benignity. Intratumoral calcium deposition was a not uncommon finding in malignant tumors. Conclusion: In most cases, the exact diagnosis should be made hy histological examination but it is important for treatment planning that the appropriate depiction of tumor extension and tissue characterization be made by MR and CT. (orig.)

  16. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H

    2015-01-01

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology

  17. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.

  18. CT analysis of intratumoral gas formation after hepatic tumor embolization

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Ahn, In Oak; Kim, Hyung Jin; Lee, Goo; Chung, Sung Hoon

    1994-01-01

    To evaluate the prevalence and the patterns of sterile gas shown at computed tomography(CT) after transarterial embolization(TAE) for primary hepatic tumor. Among 102 patients who performed TAE for hepatoma, thirty-four in whom follow-up CT was underwent constituted the basis of our study. At CT, we evaluated the patterns and locations of intratumoral gas. We also reviewed the clinical data to exclude an infectious origin of intratumoral gas. Of 34 patients, intratumoral gas was detected in 11 patients(32%), in all of whom Gelfoam was used as an embolic material. The initial tumor size measured at pre-TAE CT was larger in patients with intratumoral gas than in patients without it(p < 0.005). No specific patterns or locations of intratumoral gas were noted on CT scans. No patients had clinical signs and symptoms that suggested infection. Intratumoral gas formation without clinical evidence of infection is not an infrequent finding after TAE for hepatoma, especially when Gelfoam is used and when the tumor is larger in size. This finding may be a part of postinfarction syndrome and should not be misinterpreted as an postprocedural abscess formation

  19. Proliferación tumoral en brazo derecho Tumor proliferation in the right arm

    Directory of Open Access Journals (Sweden)

    Martin Sangueza

    2009-07-01

    Full Text Available Se presenta un caso de lesión tumoral de rápido crecimiento en la parte posterior del brazo derecho de una paciente de sexo femenino de 37 años de edad. Son discutidas las características dermatopatológicas e inmuno histoquímicas que determinan el diagnóstico definitivo.It is a case of fast growth tumor lesion on the posterior region of the right arm of a 37-year-old female patient. Dermatopathological and immunohistochemical characteristics are discussed to support the definite diagnosis.

  20. Knochenstoffwechsel bei malignen Erkrankungen

    Directory of Open Access Journals (Sweden)

    Keck A-V

    2003-01-01

    Full Text Available Bei malignen Erkrankungen, wie dem Mammakarzinom, dem Prostatakarzinom, dem Bronchialkarzinom oder dem multiplen Myelom ist der Knochen eines der am häufigsten von Metastasen betroffenen Organe. Das klinische Beschwerdebild ist durch das Auftreten pathologischer Frakturen, Schmerzen und Hyperkalzämien gekennzeichnet. Eine erhöhte Knochenresorptionsrate und Verlust an Knochenmasse im Sinne von osteoporoseartigen Veränderungen bedingt durch eine inadäquat überschießende Osteoklastendifferenzierung und -aktivierung sind ursächlich dafür verantwortlich. Durch jüngst publizierte Ergebnisse diverser Studien und Untersuchungen konnten die genauen Mechanismen der Rekrutierung und Aktivierung von Osteoklasten weiter aufgeklärt werden. Receptor activator of nuclear factor-kappa-B ligand (RANKL, ein Mitglied der Tumor necrosis factor (TNF Superfamilie konnte als entscheidender Faktor in der Osteoklastengenese identifiziert werden. Die Interaktion von RANKL mit seinem Rezeptor RANK (receptor activator of nuclear factor-kappa-B induziert die Entwicklung der osteoklastären Reihe aus dem hämatopoetischen Kompartment und fördert weiters die Differenzierung zu Osteoklastenvorstufen und die Aktivierung reifer Osteoklasten, ebenso wird eine verzögert einsetzende Apoptose bewirkt. Neben RANK und RANKL ist Osteoprotegerin (OPG als dritte Komponente in der Regulation der Knochenresorption involviert. Als Mitglied der TNF-Superfamilie bindet OPG an RANKL und blockiert somit alle stimulierenden Effekte von RANK auf die Osteoklastenentwicklung und neutralisiert so alle biologischen Effekte von RANKL. Diverse Hormone und Zytokine üben durch die Modifikation der Ratio von RANKL zu OPG einen regulatorischen Effekt auf die Knochenresorption aus. Diese ist bei osteolytischen Knochenmetastasen, beim multiplen Myelom und bei der malignen Hyperkalzämie erhöht. Das Gleichgewicht knochenaufbauender wie -abbauender Mechanismen scheint somit durch die Ratio von

  1. LINC00673 rs11655237 C>T confers neuroblastoma susceptibility in Chinese population.

    Science.gov (United States)

    Zhang, Zhuorong; Chang, Yitian; Jia, Wei; Zhang, Jiao; Zhang, Ruizhong; Zhu, Jinhong; Yang, Tianyou; Xia, Huimin; Zou, Yan; He, Jing

    2018-02-28

    Neuroblastoma, which accounts for approximately 10% of all pediatric cancer-related deaths, has become a therapeutic challenge and global burden attributed to poor outcomes and mortality rates of its high-risk form. Previous genome-wide association studies (GWASs) identified the LINC00673 rs11655237 C>T polymorphism to be associated with the susceptibility of several malignant tumors. However, the association between this polymorphism and neuroblastoma susceptibility is not clear. We genotyped LINC00673 rs11655237 C>T in 393 neuroblastoma patients in comparison with 812 age-, gender-, and ethnicity-matched healthy controls. We found a significant association between the LINC00673 rs11655237 C>T polymorphism and neuroblastoma risk (TT compared with CC: adjusted odds ratio (OR) =1.80, 95% confidence interval (CI) =1.06-3.06, P =0.029; TT/CT compared with CC: adjusted OR =1.31, 95% CI =1.02-1.67, P =0.033; and T compared with C: adjusted OR =1.29, 95% CI =1.06-1.58, P =0.013). Furthermore, stratified analysis indicated that the rs11655237 T allele carriers were associated with increased neuroblastoma risk for patients with tumor originating from the adrenal gland (adjusted OR =1.51, 95% CI =1.06-2.14, P =0.021) and International Neuroblastoma Staging System (INSS) stage IV disease (adjusted OR =1.60, 95% CI =1.12-2.30, P =0.011). In conclusion, we verified that the LINC00673 rs11655237 C>T polymorphism might be associated with neuroblastoma susceptibility. Prospective studies with a large sample size and different ethnicities are needed to validate our findings. © 2018 The Author(s).

  2. Evaluation of thymic tumors with 18F-FDG PET-CT - A pictorial review

    International Nuclear Information System (INIS)

    Sharma, Punit; Singhal, Abhinav; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh; Kumar, Arvind

    2013-01-01

    Thymic tumors represent a broad spectrum of neoplastic disorders and pose considerable diagnostic difficulties. A non-invasive imaging study to determine the nature of thymic lesions can have significant impact on management of such tumors. 18F-flurorodeoxyglucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) has shown promising results in characterization of thymic tumors. The objective of this article is to provide an illustrative tutorial highlighting the clinical utility of 18F-FDG PET-CT imaging in patients with thymic tumors. We have pictorially depicted the 18F-FDG PET-CT salient imaging characteristics of various thymic tumors, both epithelial and non-epithelial. Also discussed is the dynamic physiology of thymus gland which is to be kept in mind when evaluating thymic pathology on 18F-FDG PET-CT, as it can lead to interpretative pitfalls

  3. CT features of invasion of sublingual space by malignant oropharyngeal tumors

    International Nuclear Information System (INIS)

    Wei Yi; Xiao Jiahe; Zhou Xiangping; Deng Kaihong

    2003-01-01

    Objective: To investigate the CT features of the invasion of sublingual space by malignant oropharyngeal tumors in order to provide more accurate information for clinical treatment. Methods: Fifty-eight cases of pathologically proven malignant oropharyngeal tumors were collected and retrospectively analyzed. Results: Among all the cases, invasion of sublingual space by malignant oropharyngeal tumors could be seen in 14 cases, of which, 7 cases got access to sublingual space through tongue base, 3 cases through parapharyngeal space, 2 cases through pterygomandibular raphe, 2 cases through uncertain routes. Invasion of sublingual space manifested on CT scan as obliteration of fat plane in sublingual space and involvement of the sublingual vessels in the space. Conclusion: Malignant oropharyngeal tumors can invade the adjacent sublingual space via tongue base, pterygomandibular raphe, and parapharyngeal space. The invasion of sublingual space by malignant oropharyngeal tumors manifests in CT as effacement of sublingual fat plane and envelopment of hyoid artery

  4. Gastric stromal tumor: two-phase dynamic CT findings with water as oral contrast agents

    International Nuclear Information System (INIS)

    Lee, Se Hyo; Cho, June Sik; Shin, Kyung Sook; Jeong, Ki Ho; Park, Jin Yong; Yu, Ho Jun; Kim, Young Min; Jeon, Kwang Jin

    2000-01-01

    To evaluate two-phase dynamic CT with water as oral contrast agents in the CT diagnosis of gastric stromal tumors. We retrospectively reviewed the CT findings in 21 patients with pathologically proven gastric stromal tumors. Six were found to be benign, twelve were malignant, and there were three cases of STUMP (stromal tumor uncertain malignant potential). Two-phase dynamic CT scans with water as oral contrast agents were obtained 60-70 secs (portal phase) and 3 mins (equilibrium phase) after the start of IV contrast administration. We determined the size, growth pattern, and enhancement pattern of the tumors and overlying mucosa, the presence or absence of ulceration and necrosis, tumor extent, and lymph nod and distant metastasis. The CT and pathologic findings were correlated. All six benign tumors and three STUMP were less than 5.5 cm in size, and during the portal phase showed round endogastric masses with highly enhanced, intact overlying mucosa. Twelve malignant tumors were 4.5-15.5 cm in size (mean, 11.5 cm); an endogastric mass was seen in three cases, an exogastric mass in one, and a mixed pattern in eight. On portal phase images the tumors were not significantly enhanced, but highly enhanced feeding vessels were noted in five larger tumors (greater than 10 cm). All 12 malignant tumors showed ulceration and necrosis, and interruption of overlying mucosa was clearly seen during the portal phase. We were readily able to evaluate tumor extent during this phase, and in ten malignant tumors there was no invasion of adjacent organs. Seven malignant tumors showed air density within their necrotic portion (p less than 0.05). On equilibrium phase images, all malignant tumors showed heterogeneous enhancement due to necrosis, and poorly enhanced overlying mucosa. Dynamic CT during the portal phase with water as oral contrast agents was useful for depicting the submucosal origin of gastric stromal tumors and for evaluating the extent of malignant stromal tumors. Our

  5. An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study.

    Science.gov (United States)

    Fallavollita, Pascal; Brand, Alexander; Wang, Lejing; Euler, Ekkehard; Thaller, Peter; Navab, Nassir; Weidert, Simon

    2016-11-01

    Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.

  6. Multimodal imaging in neurofibromatosis type 1-associated nerve sheath tumors; Multimodale Bildgebung bei Neurofibromatose-Typ-1-assoziierten Nervenscheidentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, J.; Adam, G. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Mautner, V.F. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Neurology; Derlin, T. [Hannover Medical School, Hannover (Germany). Dept. of Nuclear Medicine

    2015-12-15

    Neurofibromatosis type 1 (NF1) is a neurogenetic disorder. Individuals with NF1 may develop a variety of benign and malignant tumors of which peripheral nerve sheath tumors represent the most frequent entity. Plexiform neurofibromas may demonstrate a locally destructive growth pattern, may cause severe symptoms and may undergo malignant transformation into malignant peripheral nerve sheath tumors (MPNSTs). Whole-body magnetic resonance imaging (MRI) represents the reference standard for detection of soft tissue tumors in NF1. It allows for identification of individuals with plexiform neurofibromas, for assessment of local tumor extent, and for evaluation of whole-body tumor burden on T2-weighted imaging. Multiparametric MRI may provide a comprehensive characterization of different tissue properties of peripheral nerve sheath tumors, and may identify parameters associated with malignant transformation. Due to the absence of any radiation exposure, whole-body MRI may be used for serial follow-up of individuals with plexiform neurofibromas. {sup 18}F-fluorodeoxyglucose positron-emission-tomography (FDG PET/CT) allows a highly sensitive and specific detection of MPNST, and should be used in case of potential malignant transformation of a peripheral nerve sheath tumor. PET/CT provides a sensitive whole-body tumor staging. The use of contrast-enhanced CT for diagnosis of peripheral nerve sheath tumors is limited to special indications. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of peripheral nerve sheath tumors are required.

  7. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  8. Comparison of MR imaging and CT in the evaluation of uterine tumors

    International Nuclear Information System (INIS)

    Janus, C.L.; Dottino, P.; Brodman, M.; Goodman, H.; Gendal, E.S.; Rabinowitz, J.G.

    1987-01-01

    The authors compared the usefulness of MR imaging and CT in staging uterine tumors. Forty women with known cervical carcinoma, endometrial cancer, or leiomyosarcoma underwent CT and MR imaging within 1 week prior to surgery. MR imaging was better than CT for localizing tumors to the endometrium of myometrium and in the evaluation of lymph node involvement and extension to the cervix and parametria. MR imaging, with its superior ability to demonstrate pelvic anatomy and its lack of ionizing radiation and risk from iodinated contrast media, has an important place in the staging of uterine tumors

  9. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  10. Radiological diagnostics in CUP syndrome; Radiologische Diagnostik des CUP-Syndroms

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, P.M.; Nikolaou, K.; Graser, A.; Reiser, M.F.; Cyran, C.C. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Rominger, A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2014-02-15

    , diffusion), e.g. investigation of breast carcinoma or prostate carcinoma. Whole body staging stands at the beginning of the diagnostic algorithm in CUP syndrome to localize a potential primary tumor. Clinically, contrast-enhanced CT of the neck, thorax and abdomen is frequently applied; however, many studies have demonstrated augmented sensitivity of {sup 18}F-FDG PET-CT for the detection of primary tumors and metastatic tumor manifestations. (orig.) [German] Im therapeutischen Management des Cancer-of-unknown-primary(CUP)-Syndroms spielt die bildgebende Diagnostik eine zentrale Rolle zur Lokalisation des Primaertumors, zur Identifikation von Tumoren, fuer die ein dediziertes Behandlungsschema zur Verfuegung steht, sowie zur Charakterisierung klinisch-pathologischer Subentitaeten, die das weitere diagnostische und therapeutische Procedere bestimmen und eine Einschaetzung der Prognose erlauben. Zur Verfuegung stehende radiologische Modalitaeten umfassen die Projektionsradiographie, die Computertomographie (CT), die Magnetresonanztomographie (MRT) und die Sonographie sowie die Hybridverfahren Positronenemissionstomographie(PET)-CT und MR-PET. In der Ganzkoerperbildgebung hat die CT eine hohe Sensitivitaet fuer Tumoren, die haeufig als metastasierte Tumorerkrankung auftreten. Nach aktueller Literatur ist die CT bei Patienten mit Pankreaskarzinom in 86% der Faelle diagnostisch, bei Patienten mit Kolonkarzinom in 36% und bei Patienten mit Bronchialkarzinom in 74%. Des Weiteren zeigte eine Metaanalyse, dass bei Patienten mit Plattenepithelkarzinom und zervikalen Lymphknotenmetastasen die CT in 22% der Faelle den Primaertumor lokalisieren konnte, im Vergleich zu 36% Detektionsrate der MRT und 28-57% der PET-CT mit {sup 18}F-FDG (Fluordesoxyglukose). Der MRT kommt auf Grund des hohen Weichteilkontrasts und der Moeglichkeit zur funktionellen Bildgebung besondere Bedeutung bei der Lokalisation primaer okkulter Tumoren bei Organuntersuchungen zu, z. B. beim Mamma- oder dem

  11. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    International Nuclear Information System (INIS)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae; Huh, Young

    2015-01-01

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

  12. Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT

    International Nuclear Information System (INIS)

    Kotsianos, D.; Rock, C.; Wirth, S.; Linsenmaier, U.; Brandl, R.; Fischer, T.; Pfeifer, K.J.; Reiser, M.; Euler, E.; Mutschler, W.

    2002-01-01

    Purpose: To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Method: Human knee specimens (n=22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Mueller AO classification. To confirm the results, the specimens were finally surgically dissected. Results: 97% of the tibial condylar fractures were easily seen and correctly classified according to the Mueller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. (orig.) [de

  13. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  14. CT findings in the leptomeningeal dissemination of tumors

    International Nuclear Information System (INIS)

    Yamazaki, Shingo; Ito, Umeo; Tomita, Hiroki; Takada, Yoshiaki; Ohno, Kikuo; Momma, Seiji; Inaba, Yutaka.

    1986-01-01

    The communicating hydrocephalus, the enhancement of the basal and quadrigeminal cisterns, and the enhancement of the Sylvian fissure, the cortical sulci and the ventricular wall are CT findings reported with regard to the leptomeningeal dissemination of tumors (LMDT). However, these findings are not always observed in patients with LMDT. In the present study, CT findings on 4 patients with LMDT (one from spinal ependymoblastoma, two from gastric cancer; and one from pulmonary cancer) are reported. Depending on the stage of the disease, the appearances of the above LMDT are quite varied. In Case 1, only hydrocephalus was found on admission CT. About one month later, the enhancement of the basal cisterns, the Sylvian fissure, the cerebral sulci, and the ventricular wall was observed, and this enhancement was further intensified later on. In Case 2, the cortical sulci were enhanced without any enhancement of the hydrocephalus or anything else. In Case 3, only the cerebral margin of the posterior lobectomy was enhanced. In Case 4, only a communicating hydrocephalus was observed. However, in all four cases the CSF cytology was positive for tumor cells. The frequency of each CT finding is discussed for the reported 25 cases. (author)

  15. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  16. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  17. Retroperitoneal relapse of non-seminomatous testicular cancer: computed tomography findings before retroperitoneal lymphadenectomy; Retroperitoneale Rezidive nicht-seminomatoeser Hodentumoren: Computertomographische Befunde vor retroperitonealer Lymphadenektomie

    Energy Technology Data Exchange (ETDEWEB)

    Hosten, N.; Stroszczynski, C.; Lemke, M.; Felix, R. [Strahlenklinik und Poliklinik, Charite Campus Virchow, Humboldt Univ. zu Berlin (Germany); Rick, O. [Abt. Innere Medizin mit Schwerpunkt Haematologie/Onkologie, Charite Campus Virchow, Humboldt Univ. zu Berlin (Germany)

    1999-01-01

    Purpose: In relapsing testicular cancer, additional chemotherapy is followed by abdominal CT. If residual lesions are found, retroperitoneal lymphadenectomy is considered. We studied retrospectively whether morphological criteria can help in selected cases in deciding about lymphadenectomy by distinguishing between vital tumor, scarring and mature teratoma. Methods: In 26 patients who had been treated by salvage chemotherapy and retroperitoneal lymphadenectomy for non-seminomatous testicular cancer between 1990 and 1997, abdominal computed tomography and histology were correlated. Results: Histological examination found scarring in 10 patients, vital tumor in 6, mature teratoma in 4, and simultaneous teratoma and vital tumor in 6. A single CT criterion for distinguishing between these histologies was not identified. In two patients with large masses which were partly cystic and partly solid vital tumor and teratoma were verified. Scarrings may be expected in cystic lesions at the level of the renal hilus which are lined by a thin and smooth wall. Size did not matter. Conclusion: Accurate differentiation between vital tumor and necrosis was not possible. Before lymphadenectomy CT, however, localised lesions. (orig.) [Deutsch] Ziel: Bei Patienten mit rezidivierten Hodentumoren wird nach erneuter Chemotherapie die abdominelle CT durchgefuehrt. Wenn verbliebene Raumforderungen nachgewiesen werden, wird eine retroperitoneale Lymphadenektomie in Betracht gezogen. Untersucht wurde, ob der Bildbefund Hinweise auf das Vorliegen von vitalem Tumor, Nekrose bzw. Narbe oder reifem Teratom geben kann, die in Einzelfaellen zur Indikationsstellung herangezogen werden koennten. Methoden: Bei 26 Patienten, die wegen eines rezidivierten nicht-seminomatoesen Hodentumors in den Jahren 1990 bis 1997 einer erneuten Chemotherapie mit anschliessender retroperitonealer Lymphadenektomie von Tumorresten unterzogen worden waren, wurden abdominelle CT und Histologie korreliert. Ergebnisse: Die

  18. Preoperative CT prediction for Masaoka staging of thymic epithelial tumor

    International Nuclear Information System (INIS)

    Feng Zhan; Huang Zhen; Zhang Liang

    2013-01-01

    Objective: To discuss the value of CT prognosis on the Masaoka staging system of thymic epithelial tumors (TET) before surgical resection. Methods: The CT images of 102 patients with TET proved by surgery and pathology were reviewed retrospectively. The TET were reclassified according to Masaoka stage system. The size, homogeneity, sharp, contour, infiltration of surrounding tissue, and metastasis on CT were analyzed with Logistic analysis. The diagnostic value was also evaluated with a ROC curve. Results: Masaoka pathologic stages were stage Ⅰ for 36 (35.3 %), stage Ⅱ for 27 (26.5 %), stage Ⅲ for 30 (29.4 %), and stage Ⅳ for 9 (8.8 %). A multivariable Logistic regression model showed that TET with larger size of tumor (20/35, P = 0.0371, OR = 4.539), irregular or lobulated tumor contour (26/42, P = 0.0230, OR = 4.870), heterogeneous (21/33, P = 0.0154, OR = 6.020), infiltration of surrounding fat (25/32, P = 0.0019, OR = 14.005), and pleural seeding (11/11, P = 0.0032, OR = 36.153) were more likely to have stage Ⅲ or Ⅳ disease. The area under ROC curve was 0.940. Conclusions: The tumor CT imaging features can differentiate between stage Ⅰ, Ⅱ and stage Ⅲ, Ⅳ disease. This helps identified patients more likely to benefit from neoadjuvant therapy. (authors)

  19. The value of metrizamide CT cisternography in the diagnosis of suprasellar and posterior fossa tumors

    International Nuclear Information System (INIS)

    Takahara, Nobuhiko; Mizuno, Makoto; Suwa, Jun; Yamanouchi, Yasuo; Matsumura, Hiroshi

    1982-01-01

    We have studied the diagnostic value of metrizamide CT cisternography (MCTC) in 22 patients. Six patients received metrizamide for the delineation of suprasellar tumors, 8 for posterior fossa tumors, and 8 for miscellaneous lesions, such as congenital cystic lesions and subdural fluid collections. Metrizamide with a concentration of 170 mgI/ml was used; 10 ml of it was introduced through the lumbar intrathecal route in every case. The patients were kept in a 15-degree Trendelenburg position, and Computed Tomography with an ACTA scanner (ACTA 200FS) was performed in principle one hour after the intrathecal injection and, if necessary, serially thereafter. The morphology of the subarachnoid space was well visualized in detail by CSF enhancement with metrizamide in all cases. The contours of the tumors in and around the basal cisterns were clearly shown; their relationship to the adjacent structures became more evident upon direct coronal section or upon coronal and sagittal reconstruction. It is suggested that the differential diagnosis in the suprasellar tumors and the C-P angle tumors can be made by means of the exact representation of the contours and extension of these tumors. MCTC can delineate the brain-stem glioma more accurately than the conventional CT scan: thus, it offers a definite advantage for the diagnosis and evaluation of those tumors which show isodensity on precontrast and no enhancement on postcontrast conventional CT scan. An arachnoid cyst or a porencephalic cyst can be diagnosed by the evaluation of the CSF-flow pattern. (author)

  20. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B; He, W; Cvetkovic, D; Chen, L; Fan, J; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

  1. Imaging of lung metastasis tumor mouse model using [{sup 18}F]FDG small animal PET and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Youp; Woo, Sang Keun; Lee, Tae Sup [Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)] (and others)

    2007-02-15

    The purpose of this study is to image metastaic lung melanoma model with optimal pre-conditions for animal handling by using [{sup 18}F]FDG small animal PET and clinical CT. The pre-conditions for lung region tumor imaging were 16-22 h fasting and warming temperature at 30 .deg. C. Small animal PET image was obtained at 60 min postinjection of 7.4 MBq [{sup 18}F]FDG and compared pattern of [{sup 18}F]FDG uptake and glucose standard uptake value (SUVG) of lung region between Ketamine/Xylazine (Ke/Xy) and Isoflurane (Iso) anesthetized group in normal mice. Metastasis tumor mouse model to lung was established by intravenous injection of B16-F10 cells in C57BL/6 mice. In lung metastasis tumor model, [{sup 18}F]FDG image was obtained and fused with anatomical clinical CT image. Average blood glucose concentration in normal mice were 128.0 {+-} 22.87 and 86.0 {+-} 21.65 mg/dL in Ke/Xy group and Iso group, respectively. Ke/Xy group showed 1.5 fold higher blood glucose concentration than Iso group. Lung to Background ratio (L/B) in SUVG image was 8.6 {+-} 0.48 and 12.1 {+-}0.63 in Ke/Xy group and Iso group, respectively. In tumor detection in lung region, [{sup 18}F]FDG image of Iso group was better than that of Ke/Xy group, because of high L/B ratio. Metastatic tumor location in [{sup 18}F]FDG small animal PET image was confirmed by fusion image using clinical CT. Tumor imaging in small animal lung region with [{sup 18}F]FDG small animal PET should be considered pre-conditions which fasting, warming and an anesthesia during [{sup 18}F]FDG uptake. Fused imaging with small animal PET and CT image could be useful for the detection of metastatic tumor in lung region.

  2. Early clinical esophageal adenocarcinoma (cT1): Utility of CT in regional nodal metastasis detection and can the clinical accuracy be improved?

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt Cuellar, Sonia L., E-mail: slbetancourt@mdanderson.org; Sabloff, Bradley, E-mail: bsabloff@mdanderson.org; Carter, Brett W., E-mail: bcarter2@mdanderson.org; Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org; Correa, Arlene M., E-mail: amcorrea@mdanderson.org; Maru, Dipen M., E-mail: dmaru@mdanderson.org; Ajani, Jaffer A., E-mail: jajani@mdanderson.org; Erasmus, Jeremy J., E-mail: jerasmus@mdanderson.org; Hofstetter, Wayne L., E-mail: whofstetter@mdanderson.org

    2017-03-15

    Introduction: Treatment of early esophageal cancer depends on the extent of the primary tumor and presence of regional lymph node metastasis.(RNM). Short axis diameter >10 mm is typically used to detect RNM. However, clinical determination of RNM is inaccurate and can result in inappropriate treatment. Purpose of this study is to evaluate the accuracy of a single linear measurement (short axis > 10 mm) of regional nodes on CT in predicting nodal metastasis, in patients with early esophageal cancer and whether using a mean diameter value (short axis + long axis/2) as well as nodal shape improves cN designation. Methods: CTs of 49 patients with cT1 adenocarcinoma treated with surgical resection alone were reviewed retrospectively. Regional nodes were considered positive for malignancy when round or ovoid and mean size >5 mm adjacent to the primary tumor and >7 mm when not adjacent. Results were compared with pN status after esophagectomy. Results: 18/49 patients had pN+ at resection. Using a single short axis diameter >10 mm on CT, nodal metastasis (cN) was positive in 7/49. Only 1 of these patients was pN+ at resection (sensitivity 5%, specificity 80%, accuracy 53%). Using mean size and morphologic criteria, cN was positive in 28/49. 11 of these patients were pN+ at resection (sensitivity 61%, specificity 45%, accuracy 51%). EUS with limited FNA of regional nodes resulted in 16/49 patients with pN+ being inappropriately designated as cN0. Conclusions: Evaluation of size, shape and location of regional lymph nodes on CT improves the sensitivity of cN determination compared with a short axis measurement alone in patients with cT1 esophageal cancer, although clinical utility is limited.

  3. CT and MR imaging findings of palatal tumors

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Makita, Hiroki; Kato, Keizo; Hatakeyama, Daijiro; Shibata, Toshiyuki; Mizuta, Keisuke; Aoki, Mitsuhiro

    2014-01-01

    Palatal tumors commonly arise from the minor salivary glands, and benign tumors account for approximately half of all minor salivary gland tumors. Minor salivary gland tumors have an affinity for the posterior hard palate and soft palate and virtually never arise in the midline, probably because of the distribution of palatal salivary glands. The majority of benign salivary gland tumors of the palate are pleomorphic adenomas, while the most common malignant salivary gland tumor is adenoid cystic carcinoma, followed by mucoepidermoid carcinoma, adenocarcinoma, and polymorphous low-grade adenocarcinoma. Epithelial tumors frequently arise from the soft palate. The majority of benign epithelial tumors of the palate are papillomas, while most malignant epithelial tumors are squamous cell carcinomas. Various types of mesenchymal tumors, including fibromas, lipomas, schwannomas, neurofibromas, hemangiomas, and lymphangiomas, also involve the palate. This article describes the CT and MR findings of benign and malignant palatal tumors

  4. CT and MR imaging findings of palatal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki, E-mail: hkato@gifu-u.ac.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Kanematsu, Masayuki, E-mail: masa_gif@yahoo.co.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); High-level Imaging Diagnosis Center, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Makita, Hiroki, E-mail: makitah@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Kato, Keizo, E-mail: keizo@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Hatakeyama, Daijiro, E-mail: hatakeya@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Shibata, Toshiyuki, E-mail: shibat@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Mizuta, Keisuke, E-mail: kmizuta@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan); Aoki, Mitsuhiro, E-mail: aoki@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan)

    2014-03-15

    Palatal tumors commonly arise from the minor salivary glands, and benign tumors account for approximately half of all minor salivary gland tumors. Minor salivary gland tumors have an affinity for the posterior hard palate and soft palate and virtually never arise in the midline, probably because of the distribution of palatal salivary glands. The majority of benign salivary gland tumors of the palate are pleomorphic adenomas, while the most common malignant salivary gland tumor is adenoid cystic carcinoma, followed by mucoepidermoid carcinoma, adenocarcinoma, and polymorphous low-grade adenocarcinoma. Epithelial tumors frequently arise from the soft palate. The majority of benign epithelial tumors of the palate are papillomas, while most malignant epithelial tumors are squamous cell carcinomas. Various types of mesenchymal tumors, including fibromas, lipomas, schwannomas, neurofibromas, hemangiomas, and lymphangiomas, also involve the palate. This article describes the CT and MR findings of benign and malignant palatal tumors.

  5. 18F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    International Nuclear Information System (INIS)

    London, Kevin; Stege, Claudia; Kaspers, Gertjan; Cross, Siobhan; Dalla-Pozza, Luciano; Onikul, Ella; Graf, Nicole; Howman-Giles, Robert

    2012-01-01

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV max and greater SUV max reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  6. CT-criteria of orbital hemangiomas and their importance in differential diagnosis of intraconal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Unsoeld, R; Hoyt, W F [California Univ., San Francisco (USA). Dept. of Neurosurgery; California Univ., San Francisco (USA). Dept. of Neurology and Opthalmology; California Univ., San Francisco (USA). Dept. of Neuroradiology)

    1979-12-01

    CT-Scans of 29 histologically proven cavernous hemangiomas were evaluated with respect to their location, shape, delineation from surrounding tissue, contrast-enhancement, and secondary changes of the bony orbit. Whenever a round or oval tumor, located in the outer upper muscle cone, sharply delineated from surrounding tissue, unattached to optic nerve and ocular muscles, spares a small triangular space in the orbital apex, it is in all probability a cavernous hemangioma. Evaluation of the tumors shape and its separation from surrounding tissues requires imaging in multiple sections in two planes oriented, if possible, at right angles. Changes in position of the optic nerve and eye muscles in different directions of gaze demonstrated by CT rule out significant tumor-attachments. The portion of the intraconal space least affected by optic nerve shifts and muscle contractions during eye movements, as demonstrated by CT, is the upper outer quadrant, the site preferred by the mobile tumor. Tumors which cannot be differentiated from cavernous hemangiomas by CT-criteria are rare usually benign. Reports of rare examples of well delineated or encapsulated malignant intraconal lesions indicate the possibility - however remote - of mistaking a malignant tumor for a cavernous hemangioma by CT.

  7. Characterization of tumor heterogeneity using dynamic contrast enhanced CT and FDG-PET in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Elmpt, Wouter van; Das, Marco; Hüllner, Martin; Sharifi, Hoda; Zegers, Catharina M.L.; Reymen, Bart; Lambin, Philippe; Wildberger, Joachim E.; Troost, Esther G.C.; Veit-Haibach, Patrick; De Ruysscher, Dirk

    2013-01-01

    Purpose: Dynamic contrast-enhanced CT (DCE-CT) quantifies vasculature properties of tumors, whereas static FDG-PET/CT defines metabolic activity. Both imaging modalities are capable of showing intra-tumor heterogeneity. We investigated differences in vasculature properties within primary non-small cell lung cancer (NSCLC) tumors measured by DCE-CT and metabolic activity from FDG-PET/CT. Methods: Thirty three NSCLC patients were analyzed prior to treatment. FDG-PET/CT and DCE-CT were co-registered. The tumor was delineated and metabolic activity was segmented on the FDG-PET/CT in two regions: low (<50% maximum SUV) and high (⩾50% maximum SUV) metabolic uptake. Blood flow, blood volume and permeability were calculated using a maximum slope, deconvolution algorithm and a Patlak model. Correlations were assessed between perfusion parameters for the regions of interest. Results: DCE-CT provided additional information on vasculature and tumor heterogeneity that was not correlated to metabolic tumor activity. There was no significant difference between low and high metabolic active regions for any of the DCE-CT parameters. Furthermore, only moderate correlations between maximum SUV and DCE-CT parameters were observed. Conclusions: No direct correlation was observed between FDG-uptake and parameters extracted from DCE-CT. DCE-CT may provide complementary information to the characterization of primary NSCLC tumors over FDG-PET/CT imaging

  8. Therapeutic efficacy and microSPECT/CT imaging of {sup 188}Re-DXR-liposome in a C26 murine colon carcinoma solid tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y.-J.; Chang, C.-H.; Yu, C.-Y.; Chang, T.-J.; Chen, L.-C. [Institute of Nuclear Energy Research, Taoyuan, Taiwan (China); Chen, M.-H. [National Health Research Institutes, Miaoli, Taiwan (China); Lee, T.-W. [Institute of Nuclear Energy Research, Taoyuan, Taiwan (China); Ting Gann [National Health Research Institutes, Miaoli, Taiwan (China)], E-mail: gann.ting@msa.hinet.net

    2010-01-15

    Nanocarriers can selectively target cancer sites and carry payloads, thereby improving diagnostic and therapeutic effectiveness and reducing toxicity. The objective of this study was to investigate the therapeutic efficacy of a new co-delivery radiochemotherapeutics of {sup 188}Re-N,N-bis (2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA)-labeled pegylated liposomal doxorubicin (DXR) ({sup 188}Re-DXR-liposome) in a C26 murine colon carcinoma solid tumor model. To evaluate the targeting and localization of {sup 188}Re-DXR-liposome in C26 murine tumor-bearing mice, biodistribution, microSPECT/CT imaging and pharmacokinetic studies were performed. The antitumor effect of {sup 188}Re-DXR-liposome was assessed by tumor growth inhibition, survival ratio and histopathological hematoxylin-eosin staining. The tumor target and localization of the nanoliposome delivery radiochemotherapeutics of {sup 188}Re-DXR-liposome were demonstrated in the biodistribution, pharmacokinetics and in vivo nuclear imaging studies. In the study on therapeutic efficacy, the tumor-bearing mice treated with bimodality radiochemotherapeutics of {sup 188}Re-DXR-liposome showed better mean tumor growth inhibition rate (MGI) and longer median survival time (MGI=0.048; 74 days) than those treated with radiotherapeutics of {sup 188}Re-liposome (MGI=0.134; 60 days) and chemotherapeutics of Lipo-Dox (MGI=0.413; 38 days). The synergistic tumor regression effect was observed with the combination index (CI) exceeding 1 (CI=1.145) for co-delivery radiochemotherapeutics of {sup 188}Re-DXR-liposome. Two (25%) of the mice treated with radiochemotherapeutics were completely cured after 120 days. The therapeutic efficacy of radiotherapeutics of {sup 188}Re-liposome and the synergistic effect of the combination radiochemotherapeutics of {sup 188}Re-DXR-liposome have been demonstrated in a C26 murine solid tumor animal model, which pointed to the potential benefit and promise of the co-delivery of

  9. F-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor

    Directory of Open Access Journals (Sweden)

    Katsuya Mitamura

    2015-01-01

    Full Text Available Primary hepatic neuroendocrine tumors (PHNETs are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG positron emission tomography (PET and fused PET/CT images showed increased uptake in the hepatic mass. Whole-body 18F-FDG PET images showed no abnormal activity except for the liver lesion. Presence of an extrahepatic tumor was also ruled out by performing upper gastrointestinal endoscopy, total colonoscopy, and chest and abdominal CT. A posterior segmentectomy was performed, and histologic examination confirmed a neuroendocrine tumor (grade 1. The patient was followed up for about 2 years after the resection, and no extrahepatic lesions were radiologically found. Therefore, the patient was diagnosed with PHNET. To the best of our knowledge, no previous case of PHNET have been detected by 18F-FDG PET imaging.

  10. The importance of PET/CT in the evaluation of patients with Ewing tumors

    Directory of Open Access Journals (Sweden)

    Júlio Brandão Guimarães

    2015-06-01

    Full Text Available Abstract The effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging.

  11. The Adnectin CT-322 is a novel VEGF receptor 2 inhibitor that decreases tumor burden in an orthotopic mouse model of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Miller Andrew F

    2008-11-01

    Full Text Available Abstract Background Pancreatic cancer continues to have a 5-year survival of less than 5%. Therefore, more effective therapies are necessary to improve prognosis in this disease. Angiogenesis is required for tumor growth, and subsequently, mediators of angiogenesis are attractive targets for therapy. Vascular endothelial growth factor (VEGF is a well-characterized mediator of tumor angiogenesis that functions primarily by binding and activating VEGF receptor 2 (VEGFR2. In this study, we evaluate the use of CT-322, a novel biologic (Adnectin. This small protein is based on a human fibronectin domain and has beneficial properties in that it is fully human, stable, and is produced in bacteria. CT-322 binds to and inhibits activation of VEGFR2. Methods The efficacy of CT-322 was evaluated in vivo using two orthotopic pancreatic tumor models. The first model was a human tumor xenograft where MiaPaCa-2 cells were injected into the tail of the pancreas of nude mice. The second model was a syngeneic tumor using Pan02 cells injected into pancreas of C57BL/6J mice. In both models, therapy was initiated once primary tumors were established. Mice bearing MiaPaCa-2 tumors were treated with vehicle or CT-322 alone. Gemcitabine alone or in combination with CT-322 was added to the treatment regimen of mice bearing Pan02 tumors. Therapy was given twice a week for six weeks, after which the animals were sacrificed and evaluated (grossly and histologically for primary and metastatic tumor burden. Primary tumors were also evaluated by immunohistochemistry for the level of apoptosis (TUNEL, microvessel density (MECA-32, and VEGF-activated blood vessels (Gv39M. Results Treatment with CT-322 was effective at preventing pancreatic tumor growth and metastasis in orthotopic xenograft and syngeneic models of pancreatic cancer. Additionally, CT-322 treatment increased apoptosis, reduced microvessel density and reduced the number of VEGF-activated blood vessels in tumors

  12. Right- vs. Left-Sided Metastatic Colorectal Cancer: Differences in Tumor Biology and Bevacizumab Efficacy

    Directory of Open Access Journals (Sweden)

    Paola Ulivi

    2017-06-01

    Full Text Available There is evidence of a different response to treatment with regard to the primary tumor localization (right-sided or left-sided in patients with metastatic colorectal cancer (mCRC. We analyzed the different outcomes and biomolecular characteristics in relation to tumor localization in 122 of the 370 patients with metastatic colorectal cancer enrolled onto the phase III prospective multicenter “Italian Trial in Advanced Colorectal Cancer (ITACa”, randomized to receive first-line chemotherapy (CT or CT plus bevacizumab (CT + B. RAS and BRAF mutations; baseline expression levels of circulating vascular endothelial growth factor (VEGF, endothelial nitric oxide synthase (eNOS, cyclooxygenase-2 (COX2, ephrin type-B receptor 4 (EPHB4, hypoxia-inducible factor 1-alpha (HIF-1α, lactate dehydrogenase (LDH, and high-sensitivity C reactive protein (hs-CRP; and inflammatory indexes such as the neutrophil-to-lymphocyte ratio, platelet-lymphocyte rate and systemic immune-inflammation index were evaluated. Patients with right-sided tumors showed a longer median progression-free survival in the CT + B arm than in the CT group (12.6 vs. 9.0 months, respectively, p = 0.017. Baseline inflammatory indexes were significantly higher in left-sided tumors, whereas eNOS and EPHB4 expression was significantly higher and BRAF mutation more frequent in right-sided tumors. Our data suggest a greater efficacy of the CT + B combination in right-sided mCRC, which might be attributable to the lower inflammatory status and higher expression of pro-angiogenic factors that appear to characterize these tumors.

  13. CT diagnosis of brain tumor types with the aid of a new, CT-controlled stereotactical device

    International Nuclear Information System (INIS)

    Huk, W.

    1980-01-01

    The hitherto unparalleled information quality of computerized tomography elicited hopes that it might also be possible to differentiate cerebral tumors according to their histologic character and degree of malignity. The present work proposes to investigate whether CT information can be useful in the diagnosis of types of brain tumors. A first part contains a critical analysis of CT findings as to their specific information value and a comparison with the possibilities previously offered by neuroradiology. In a second part, and as a consequence of the investigations in Part I, a newly developed stereotactical procedure is described combining the capacity of CT for precise location with the accuracy of aim of a stereotactical device so that cerebral proliferations evading other diagnostical attempts can be histologically cleared up. (orig./MG) [de

  14. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  15. Incidental diagnosis of tumor thrombosis on FDG PET/CT imaging.

    Science.gov (United States)

    Erhamamci, S; Reyhan, M; Nursal, G N; Torun, N; Yapar, A F

    2015-01-01

    Clinical data are presented on patients with tumor thrombosis (TT) incidentally detected on FDG PET/CT imaging, as well as determining its prevalence and metabolic characteristics. Out of 12,500 consecutive PET/CT examinations of patients with malignancy, the PET/CT images of 15 patients with TT as an incidental finding were retrospectively investigated. A visual and semiquantitative analyses was performed on the PET/CT scans. An evaluation was made of the pattern of FDG uptake in the involved vessel as linear or focal via visual analyses. For the semiquantitative analyses, the metabolic activity was measured using SUVmax by drawing the region of interest at the site of the thrombosis and tumor (if any). The prevalence of occult TT was 0.12%. A total of 15 patients had various malignancies including renal (1 patient), liver (4), pancreas (2), stomach (1), colon (1), non-Hodgkin lymphoma (1), leiomyosarcoma (1), endometrial (1), ovarian (1), malign melanoma (1) and parotid (1). Nineteen vessels with TT were identified in 15 patients; three patients had more than one vessel. Various vessels were affected; the most common was the inferior vena cava (n=7) followed by the portal (n=5), renal (n=3), splenic (n=1), jugular (n=1), common iliac (n=1) and ovarian vein (n=1). The FDG uptake pattern was linear in 12 and focal in 3 patients. The mean SUVmax values in the TT and primary tumors were 8.40±4.56 and 13.77±6.80, respectively. Occult TT from various malignancies and locations was found incidentally in 0.12% of patients. Interesting cases with malign melanoma and parotid carcinoma and with TT in ovarian vein were first described by FDG PET/CT. Based on the linear FDG uptake pattern and high SUVmax value, PET/CT may accurately detect occult TT, help with the assessment of treatment response, contribute to correct tumor staging, and provide additional information on the survival rates of oncology patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All

  16. The clinical impact of {sup 18}F-FDG PET/CT in extracranial pediatric germ cell tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Adam; Vali, Reza; Marie, Eman; Shammas, Amer [The Hospital for Sick Children and University of Toronto, Department of Medical Imaging, Nuclear Medicine, Toronto, ON (Canada); Shaikh, Furqan [The Hospital for Sick Children and University of Toronto, Division of Haematology and oncology, Toronto, ON (Canada)

    2017-10-15

    Extracranial germ cell tumors are an uncommon pediatric malignancy with limited information on the clinical impact of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the literature. The purpose of this study was to evaluate and compare the clinical impact on management of {sup 18}F-FDG PET/CT with diagnostic computed tomography (CT) in pediatric extracranial germ cell tumor. The list of {sup 18}F-FDG PET/CT performed for extracranial germ cell tumor between May 2007 and November 2015 was obtained from the nuclear medicine database. {sup 18}F-FDG PET/CT and concurrent diagnostic CT were obtained and independently reviewed. Additionally, the patients' charts were reviewed for duration of follow-up and biopsy when available. The impact of {sup 18}F-FDG PET/CT compared with diagnostic CT on staging and patient management was demonstrated by chart review, imaging findings and follow-up studies. During the study period, 9 children (5 males and 4 females; age range: 1.6-17 years, mode age: 14 years) had 11 {sup 18}F-FDG PET/CT studies for the evaluation of germ cell tumor. Diagnostic CTs were available for comparison in 8 patients (10 {sup 18}F-FDG PET/CT studies). The average interval between diagnostic CT and PET/CT was 7.2 days (range: 0-37 days). In total, five lesions concerning for active malignancy were identified on diagnostic CT while seven were identified on PET/CT. Overall, {sup 18}F-FDG PET/CT resulted in a change in management in 3 of the 9 patients (33%). {sup 18}F-FDG PET/CT had a significant impact on the management of pediatric germ cell tumors in this retrospective study. Continued multicenter studies are required secondary to the rarity of this tumor to demonstrate the benefit of {sup 18}F-FDG PET/CT in particular clinical scenarios. (orig.)

  17. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    Science.gov (United States)

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  18. Local curvature analysis for classifying breast tumors: Preliminary analysis in dedicated breast CT

    International Nuclear Information System (INIS)

    Lee, Juhun; Nishikawa, Robert M.; Reiser, Ingrid; Boone, John M.; Lindfors, Karen K.

    2015-01-01

    Purpose: The purpose of this study is to measure the effectiveness of local curvature measures as novel image features for classifying breast tumors. Methods: A total of 119 breast lesions from 104 noncontrast dedicated breast computed tomography images of women were used in this study. Volumetric segmentation was done using a seed-based segmentation algorithm and then a triangulated surface was extracted from the resulting segmentation. Total, mean, and Gaussian curvatures were then computed. Normalized curvatures were used as classification features. In addition, traditional image features were also extracted and a forward feature selection scheme was used to select the optimal feature set. Logistic regression was used as a classifier and leave-one-out cross-validation was utilized to evaluate the classification performances of the features. The area under the receiver operating characteristic curve (AUC, area under curve) was used as a figure of merit. Results: Among curvature measures, the normalized total curvature (C_T) showed the best classification performance (AUC of 0.74), while the others showed no classification power individually. Five traditional image features (two shape, two margin, and one texture descriptors) were selected via the feature selection scheme and its resulting classifier achieved an AUC of 0.83. Among those five features, the radial gradient index (RGI), which is a margin descriptor, showed the best classification performance (AUC of 0.73). A classifier combining RGI and C_T yielded an AUC of 0.81, which showed similar performance (i.e., no statistically significant difference) to the classifier with the above five traditional image features. Additional comparisons in AUC values between classifiers using different combinations of traditional image features and C_T were conducted. The results showed that C_T was able to replace the other four image features for the classification task. Conclusions: The normalized curvature measure

  19. Generalities of anomalous CT chest non tumoral

    International Nuclear Information System (INIS)

    Dibarboure, L.

    2012-01-01

    This presentation is about the generalities of multidetector CT in the pulmonary, the diaphragmatic, the pleural and the mediastinum pathology.These techniques as well as the virtual endoscopy allow visualize volumetric thorax reconstructions, brain diseases, opacities, radiolucent images, respiratory and vascular diseases, pneumonia, embolism, AIDS stage, tuberculosis, tumors, etc

  20. Prognostic value of baseline metabolic tumor volume in early stage Hodgkin's lymphoma in the standard arm of H10 trial

    DEFF Research Database (Denmark)

    Cottereau, Anne Ségolène; Versari, Annibale; Loft, Annika

    2018-01-01

    and compared to baseline characteristics, staging classifications and iPET2. A total of 258 patients were eligible, 101 favorable and 157 unfavorable. The median follow-up was 55 months, with 27 PFS and 12 OS events. TMTV was prognosticator of PFS (p...We tested baseline PET/CT as a measure of total tumor burden in order to better identify high risk patients in early-stage Hodgkin's lymphoma (HL). Stage I-II HL patients enrolled in the standard arm (combined modality treatment) of the H10 trial (NCT00433433) with available baseline PET...... and interim PET (iPET2) after two cycles of doxorubicine, bleomycin, vinblastine, dacarbazine were included. Total metabolic tumor volume (TMTV) was measured on baseline PET. IPET2 findings were reported negative (DS1-3) or positive (DS4-5) with the Deauville scale. The prognostic value of TMTV was evaluated...

  1. The immunomodulatory activities of licorice polysaccharides (Glycyrrhiza uralensis Fisch.) in CT 26 tumor-bearing mice.

    Science.gov (United States)

    Ayeka, Peter Amwoga; Bian, YuHong; Githaiga, Peter Mwitari; Zhao, Ying

    2017-12-15

    The increasing use of complementary and alternative medicine (CAM) has kindled the need for scientific evaluation of the mechanism of action of CAMs. Although, licorice, a common ingredient in many Traditional Chinese medicine (TCM) has attracted great attention for its antitumor and immunomodulatory activities, the mechanism of action of its polysaccharides is still unclear. Here we report the immunomodulatory activity of licorice polysaccharides in vivo. The differential anticancer activities of licorice polysaccharides by tumorigenesis and immunomodulation was evaluated in vivo. Six weeks old, 120 CT-26 tumor bearing BALB/c mice, weighing 20 ± 2 g were used. They were randomly divided into six groups, three groups receiving high molecular weight (fraction A), low molecular weight (fraction B) polysaccharides and crude extract (fraction C); positive, negative and normal groups receiving cytoxin, saline and normal diet respectively. Weight of mice and tumors was determined and tumorigenicity assay calculated to determine the anticancer effects. Immunomodulatory potential was determined by immune organ indices, immune cell population and serum cytokine levels using immune organ weight and index, flow cytometry and cytokine/chemokine bead panel kit respectively. Licorice polysaccharides exhibited immunomodulatory activities in CT 26 tumor bearing BALB/c mice. The polysaccharides significantly suppressed tumor growth and increased immune organ index. Furthermore, the immunomodulatory effect was evident with activation of CD4 + and CD8 + immune cells population. The polysaccharides also affected the production of various cytokines, by increasing IL 2, IL 6, IL 7 levels and a decreasing TNFα levels. In summary, licorice polysaccharide especially of low molecular weight exhibit anticancer and immunomodulatory activities by suppressing tumor growth and improving general health of mice. They also augment the thymus/spleen index and population of T lymphocytes

  2. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  3. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  4. {sup 18}F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    London, Kevin [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Paediatrics and Child Health, Sydney Medical School, Sydney, NSW (Australia); Stege, Claudia; Kaspers, Gertjan [VU Medical Centre, Divisions of Paediatric Oncology/Haematology, Amsterdam (Netherlands); Cross, Siobhan; Dalla-Pozza, Luciano [The Children' s Hospital at Westmead, Department of Oncology, Sydney (Australia); Onikul, Ella [The Children' s Hospital at Westmead, Department of Medical Imaging, Sydney (Australia); Graf, Nicole [The Children' s Hospital at Westmead, Department of Pathology, Sydney (Australia); Howman-Giles, Robert [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Imaging, Sydney Medical School, Sydney, NSW (Australia)

    2012-04-15

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV{sub max} and greater SUV{sub max} reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  5. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  6. Improvement of internal tumor volumes of non-small cell lung cancer patients for radiation treatment planning using interpolated average CT in PET/CT.

    Directory of Open Access Journals (Sweden)

    Yao-Ching Wang

    Full Text Available Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT or positron emission tomography (PET images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpolated average CT (IACT as attenuation correction (AC to diminish the occurrence of this scenario. Thirteen non-small cell lung cancer patients were recruited for the present comparison study. Each patient had full-inspiration, full-expiration CT images and free breathing PET images by an integrated PET/CT scan. IACT for AC in PET(IACT was used to reduce the PET/CT misalignment. The standardized uptake value (SUV correction with a low radiation dose was applied, and its tumor volume delineation was compared to those from HCT/PET(HCT. The misalignment between the PET(IACT and IACT was reduced when compared to the difference between PET(HCT and HCT. The range of tumor motion was from 4 to 17 mm in the patient cohort. For HCT and PET(HCT, correction was from 72% to 91%, while for IACT and PET(IACT, correction was from 73% to 93% (*p<0.0001. The maximum and minimum differences in SUVmax were 0.18% and 27.27% for PET(HCT and PET(IACT, respectively. The largest percentage differences in the tumor volumes between HCT/PET and IACT/PET were observed in tumors located in the lowest lobe of the lung. Internal tumor volume defined by functional information using IACT/PET(IACT fusion images for lung cancer would reduce the inaccuracy of tumor delineation in radiation therapy planning.

  7. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    International Nuclear Information System (INIS)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H.

    1998-01-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.)

  8. Gastrointestinal stromal tumor: role of spiral CT in diagnosis and evaluation of treatment with STI571

    International Nuclear Information System (INIS)

    Hu Jiawang; Zhou Linjiang; Wei Jiangong

    2011-01-01

    Objective: To investigate the CT appearance of gastrointestinal stromal tumors (GISTs) after oral imatinib mesylate (STI571) treatment. Methods: CT scans of 58 cases of GISTs proven by histology and immunohistochemistry were retrospectively analyzed. Dynamic contrast-enhanced CT of 8 patients after STI571 treatment was also evaluated. Results: The tumors originated from the stomach (n=28), small intestine (n=12), duodenum (n=6), colon (n=5), rectum (n=4), mesentery (n=2), and esophagus (n=2). Small GISTs appeared as round or oval, endo- or exophytic masses with well-defined margins and homogeneous contrast enhancement. Large lesions were often irregular infiltrative exophytic masses with heterogeneous enhancement. Ulceration, fistulization and neovascularity can be seen within the larger tumors. CT scans of 5 patients with good treatment response showed rapid transition form a heterogeneously hyper-attenuating pattern to homogeneously hypo-attenuating pattern with resolution of the enhancing tumor nodules and decreased tumor neovascularity. In 3 poor responders, CT showed enlarging or new enhancing nodules within the treated hypo-attenuating tumor, new lesions or metastasis outside the primary tumor. Conclusion: CT can demonstrate changes resulting from treatment of GISTs. It is valuable for guiding and assessing treatment response to STI571. (authors)

  9. c.29C>T polymorphism in the transforming growth factor-β1 (TGFB1) gene correlates with increased risk of urinary bladder cancer.

    Science.gov (United States)

    Gautam, Kirti Amresh; Pooja, Singh; Sankhwar, Satya Narayan; Sankhwar, Pushp Lata; Goel, Apul; Rajender, Singh

    2015-10-01

    TGF-β1 is a pleiotropic cytokine, which plays a dual role in tumor development. In the early stages, it inhibits the growth of tumor while in the late stages of carcinoma, it promotes tumor growth. The purpose of this study was to analyze the distribution of the TGFB1 gene polymorphisms between cases and controls so as to assess their correlation with bladder cancer risk. This study included 237 cases of urinary bladder cancer and 290 age matched controls from the same ethnic background. Three polymorphisms in the TGFB1 gene, c.29C>T (rs-1800470), c.74G>C (rs-1800471) and +140A>G (rs-13447341), were analyzed by direct DNA sequencing. Statistical analyses revealed no significant differences in the demographical data, except that the frequencies of smokers and non-vegetarians were higher in the cases. Eighty percent of the bladder cancer patients had superficial transitional cell carcinoma, and 53.16% and 26.31% of the patients were in grade I and grade II, respectively. We found that c.29C>T substitution increased the risk of bladder cancer significantly and recessive model of analysis was the best fitted model (p=0.004; OR=1.72 95% CI 1.18-2.50). A significantly higher risk in the recessive form was also suggested by co-dominant analysis showing that the homozygous form (TT) was a significant risk factor in comparison to CC and CT genotypes. The other two polymorphisms, c.74G>C (p=0.18, OR=0.67 95% CI 0.37-1.21) and +140A>G (p=0.416, OR=0.77 95% CI 0.41-1.45) did not affect the risk of urinary bladder cancer. In conclusion, we found that the TGFB1 c.29C>T substitution increases the risk of bladder cancer significantly while c.74G>C and +140A>G polymorphisms do not affect the risk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  11. TU-H-CAMPUS-JeP2-02: Interobserver Variability of CT, PET-CT and MRI Based Primary Tumor Delineation for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Karki, K; Hugo, G; Saraiya, S; Jan, N; Schuster, J; Schutzer, M; Fahrner, L; Groves, R; Ford, J; Weiss, E [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: Target delineation in lung cancer radiotherapy has, in general, large variability. MRI has so far not been investigated in detail for lung cancer delineation variability. The purpose of this study is to investigate delineation variability for lung tumors using MRI and compare it to CT alone and PET-CT based delineations. Methods: Seven physicians delineated the primary tumor volumes of nine patients for the following scenarios: (1) CT only; (2) post-contrast T1-weighted MRI registered with diffusion-weighted MRI; and (3) PET-CT fusion images. To compute interobserver variability, the median surface was generated from all observers’ contours and used as the reference surface. A single physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest-wall) on the median surface. Volume variation (normalized to PET-CT volume), minimum distance (MD), and bidirectional local distance (BLD) between individual observers’ contours and the reference contour were measured. Results: CT- and MRI-based normalized volumes were 1.61±0.76 (mean±SD) and 1.38±0.44, respectively, both significantly larger than PET-CT (p<0.05, paired t-test). The overall uncertainty (root mean square of SD values over all points) of both BLD and MD measures of the observers for the interfaces were not significantly different (p>0.05, two-samples t-test) for all imaging modalities except between tumor-mediastinum and tumor-atelectasis in PET-CT. The largest mean overall uncertainty was observed for tumor-atelectasis interface, the smallest for tumor-mediastinum and tumor-lung interfaces for all modalities. The whole tumor uncertainties for both BLD and MD were not significantly different between any two modalities (p>0.05, paired t-test). Overall uncertainties for the interfaces using BLD were similar to using MD. Conclusion: Large volume variations were observed between the three imaging modalities. Contouring variability appeared to

  12. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    International Nuclear Information System (INIS)

    Zhang Weidong; Li Chuanxing; Liu Qingyu; Hu Yingying; Cao Yun; Huang Jinhua

    2011-01-01

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  13. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.; Uneri, A.; Stayman, J. W.; Zbijewski, W.; Schmidgunst, C.; Kleinszig, G.; Khanna, A. J.; Siewerdsen, J. H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Siemens Healthcare XP Division, Erlangen (Germany); Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland 21239 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 and Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2011-08-15

    Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter

  14. Automatic lung tumor segmentation on PET/CT images using fuzzy Markov random field model.

    Science.gov (United States)

    Guo, Yu; Feng, Yuanming; Sun, Jian; Zhang, Ning; Lin, Wang; Sa, Yu; Wang, Ping

    2014-01-01

    The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  15. Automatic Lung Tumor Segmentation on PET/CT Images Using Fuzzy Markov Random Field Model

    Directory of Open Access Journals (Sweden)

    Yu Guo

    2014-01-01

    Full Text Available The combination of positron emission tomography (PET and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice’s similarity coefficient (DSC was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  16. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  17. MAGE-C2/CT10 protein expression is an independent predictor of recurrence in prostate cancer.

    Directory of Open Access Journals (Sweden)

    Lotta von Boehmer

    Full Text Available The cancer-testis (CT family of antigens is expressed in a variety of malignant neoplasms. In most cases, no CT antigen is found in normal tissues, except in testis, making them ideal targets for cancer immunotherapy. A comprehensive analysis of CT antigen expression has not yet been reported in prostate cancer. MAGE-C2/CT-10 is a novel CT antigen. The objective of this study was to analyze extent and prognostic significance of MAGE-C2/CT10 protein expression in prostate cancer. 348 prostate carcinomas from consecutive radical prostatectomies, 29 castration-refractory prostate cancer, 46 metastases, and 45 benign hyperplasias were immunohistochemically analyzed for MAGE-C2/CT10 expression using tissue microarrays. Nuclear MAGE-C2/CT10 expression was identified in only 3.3% primary prostate carcinomas. MAGE-C2/CT10 protein expression was significantly more frequent in metastatic (16.3% positivity and castration-resistant prostate cancer (17% positivity; p<0.001. Nuclear MAGE-C2/CT10 expression was identified as predictor of biochemical recurrence after radical prostatectomy (p = 0.015, which was independent of preoperative PSA, Gleason score, tumor stage, and surgical margin status in multivariate analysis (p<0.05. MAGE-C2/CT10 expression in prostate cancer correlates with the degree of malignancy and indicates a higher risk for biochemical recurrence after radical prostatectomy. Further, the results suggest MAGE-C2/CT10 as a potential target for adjuvant and palliative immunotherapy in patients with prostate cancer.

  18. Artifacts in conventional computed tomography (CT) and free breathing four-dimensional CT induce uncertainty in gross tumor volume determination

    DEFF Research Database (Denmark)

    Persson, Gitte Fredberg; Nygaard, Ditte Eklund; Af Rosenschöld, Per Munck

    2011-01-01

    was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. METHODS AND MATERIALS: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT...

  19. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  20. Development of the OPESCOPE mobile C-arm system

    International Nuclear Information System (INIS)

    Tsuji, Hisao; Kadowaki, Toshio; Shimizu, Yasumitsu

    1994-01-01

    A new mobile C-arm X-ray fluoroscopy system called the 'OPESCOPE' equipped with a CCD TV camera and high-definition Image Intensifier has been developed. All the cables for the I.I. and X-ray generator are held inside the C-arm to prevent interference with operation and the C-arm is locked electromagnetically. Moreover, the C-arm is spring counterbalanced in the vertical motion axis. These features enable smooth positioning and uncluttered operation. The X-ray generator uses a high-frequency inverter designed to assure noiseless operation and a compact size. With the new DFS-700 videoprocessor unit being combined, clearer, more informative images can be obtained. In addition to its inherent portability this unit can be upgraded in DSA function to allow angiographic examinations in the surgical theater. (author)

  1. CT diagnosis of tumor thrombus of the renal vein and inferior vena cava

    International Nuclear Information System (INIS)

    Masuda, Fujio; Chen, Zuicho; Oishi, Yukihiko; Machida, Toyohei

    1980-01-01

    We used computed tomography (CT) for diagnosis in 4 cases of renal tumor associated with tumor thrombus of the renal vein and inferior vana cava. The results obtained are described below: A total of 4 cases consisting of 3 cases of renal cell carcinoma and one case of squamous cell carcinoma of the renal pelvis, treated at the Jikei University Hospital during the six months period from January to June of 1979, were studied. The affected side was right in 3 cases and left in one case. In all of the former cases the tumor thrombus was extending from the renal vein to the inferior vena cava, while in the latter case it was confined in the renal vein. All these 4 cases received CT together with renal arteriography and inferior venacavography, followed by nephrectomy, and were confirmed of the presence of tumor thrombus in the renal vein and inferior vena cava operatively. CT findings revealed a pronounced enlargement of the renal vein, and tumor thrombus of the renal vein was diagnosed in all of the 4 cases. In 2 of 3 cases in which tumor thrombus extended to the inferior vena cava, the dilated renal vein was found to be connected to the slightly dilated inferior vena cava, while in the remaining one case the outline of the inferior vena cava was obscure, showing no clear dilatation. After contrast enhancement, a filling defect was seen in the inferior vena cava. CT findings of tumor thrombus in the vein indicated a dilatation of the renal vein and inferior vena cava. In addition, a filling defect was found after contrast enhancement, suggesting that CT is helpful as a diagnostic aid. (author)

  2. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Donat, Markus Alexander; Mehrain, Sheida; Friedrich, Klaus; Krestan, Christian; Matula, Christian; Imhof, Herwig; Czerny, Christian

    2007-01-01

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  3. Differentiation of large (≥5 cm) gastrointestinal stromal tumors from benign subepithelial tumors in the stomach: Radiologists’ performance using CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ye Ra [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Sun-Ah [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Hyung Jin; Kim, Seong Ho [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); The Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2014-02-15

    Purpose: To identify significant CT findings for the differentiation of large (≥5 cm) gastric gastrointestinal stromal tumors (GIST) from benign subepithelial tumors and to assess whether radiologists’ performance in differentiation is improved with knowledge of significant CT criteria. Materials and methods: One-hundred twenty patients with pathologically proven large (≥5 cm) GISTs (n = 99), schwannomas (n = 16), and leiomyomas (n = 5) who underwent CT were enrolled. Two radiologists (A and B) retrospectively reviewed their CT images in consensus for the location, size, degree and pattern of enhancement, contour, growth pattern and the presence of calcification, necrosis, surface ulceration, or enlarged lymph nodes. CT findings considered significant for differentiation were determined using uni- and multivariate statistical analyses. Thereafter, two successive review sessions for the differentiation of GIST from non-GIST were independently performed by two other reviewers (C and D) with different expertise of 2 and 9 years using a 5-point confidence scale. At the first session, reviewers interpreted CT images without knowledge of significant CT findings. At the second session, the results of statistical analyses were provided to the reviewers. To assess improvement in radiologists’ performance, a pairwise comparison of receiver operating curves (ROC) was performed. Results: Heterogeneous enhancement, presence of necrosis, absence of lymph nodes, and mean size of ≥6 cm were found to be significant for differentiating GIST from schwannoma (P < 0.05). Non-cardial location, heterogeneous enhancement, and presence of necrosis were differential CT features of GIST from leiomyoma (P < 0.05). Multivariate analyses indicated that absence of enlarged LNs was the only statistically significant variable for GIST differentiating from schwannoma. The area under the curve of both reviewers obtained using ROC significantly increased from 0.682 and 0.613 to 0.903 and 0

  4. ''Routine'' brain CT in psychiatric patients - does it make sense?; ''Routine''-Schaedel-CT in der psychiatrischen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Pickuth, D.; Heywang-Koebrunner, S.H.; Spielmann, R.P. [Martin-Luther-Universitaet Halle-Wittenberg, Halle (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie

    1999-11-01

    Purpose: To prospectively assess the spectrum of brain CT findings in psychiatric patients and to determine the number of patients that had an underlying cause for the symptoms. Patients and methods: Over a period of six months, 142 patients (78 males, 64 females; median age 61 [18-91] years) were referred for CT brain scans. Their scans were reviewed, along with the clinical information that was provided in the request form. All the hard copies were reviewed to assess areas of ischaemia, infarction, atrophy, tumours, and haematomas. The majority of requests were to exclude vascular event or space-occupying lesions. Clinical indications included mood disorders (depression, mania), schizophrenic disorders, dementia, personality and behavioural disorders. Results: 31 (22%) were normal. 111 (78%) had varying degrees of ischaemia, infarction and cerebral/cerebellar atrophy. 7 (4.9%) had space-occupying lesions which included two gliomas and five meningiomas. There were two chronic subdural haematomas and one arteriovenous malformation. Conclusion: 1. In our series, pathologic findings in 'routine' brain CT's were encountered in 78%. 2. The incidence of brain tumours was 4.9%, compared with 0.00005% of the general population. 3. CT scanning in psychiatric patients is cost-effective and especially indicated when there is an atypical presentation, or inadequate response to standard treatment. (orig.) [German] Hintergrund: Bei psychiatrischen Patienten wird vielerorts routinemaessig eine kraniale Computertomographie (CCT) durchgefuehrt. Ob der Nutzen die Kosten rechtfertigt, wurde im Rahmen einer Prospektivstudie untersucht. Patienten und Methode: In einem Zeitraum von 6 Monaten wurde bei 142 psychiatrischen Patienten (78 Maenner, 64 Frauen, 18-91 Jahre, Median 61 Jahre) ein CCT angefertigt. Die Untersuchung erfolgt nativ in 5-mm-Schichtdicke, bei klinischem Verdacht auf eine intrakraniale Raumforderung auch kontrastverstaerkt. Ueberweisungsdiagnosen waren v

  5. Image quality of paper prints compared to film copies in CT investigations; Bildqualitaet von Papierausdrucken zur Befunddokumentation im Vergleich zu Laserfilmen bei MSCT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Bley, T.; Burger, D.; Ghanem, N.; Thuerl, C.; Saueressig, U.; Kotter, E.; Langer, M. [Abt. Roentgendiagnostik, Radiologische Klinik, Universitaetsklinikum Freiburg (Germany)

    2002-04-01

    Purpose: Evaluation of image quality of paper prints in routine CT investigations. Method: The image quality of paper prints from 104 CT scans of daily routine investigations was analysed by three observer three observers according to a five-point ranking scale for contrast, grey level, spatial resolution, and subjective confidence in correct evaluation. Each study was rated ''acceptable'' or ''not acceptable for documentation''. Results: In 312 ratings the mean grade for contrast was 2.7, for grey levels 3.2, and for spatial resolution 3.3. Grades ranged from 1 = very good to 5 = insufficient. Subjective confidence in correct evaluation was rated as ''certain'' in 77.4%, ''likely'' in 18.4% and ''impossible to evaluate'' in 4.2% of cases. 93.7% of printed CT images were rated ''acceptable for documentation''. Conclusion: Image quality of paper prints does not reach the quality of laser films concerning its contrast, grey levels, and spatial resolution. Nevertheless, paper prints are acceptable for documentation of findings in most CT investigations. A high confidence in correct evaluation was found. Limitations are found in documentation of small coin lesions of the lung and ischemic lesions of the neurocranium. (orig.) [German] Ziel: Qualitaetsbewertung von Papierausdrucken zur Bilddokumentation von Routine-CT-Untersuchungen. Material und Methoden: Bei 104 Routine-CT-Untersuchungen werteten drei Untersucher (insgesamt 312 Auswertungen) die Bildqualitaet von Papierausdrucken im Vergleich zu Laserfilmen bezueglich Kontrast, Grauwerten und Aufloesung sowie ''persoenlicher Befundsicherheit'' (Skala 1 - 5) aus. Abschliessend wurde entschieden, ob der Papierausdruck fuer die Befunddokumentation ausreiche. Ergebnisse: Mit Bewertungen zwischen 1 fuer ''sehr gut'' und 5 fuer &apos

  6. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T{sub 2}-weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T{sub 2}-weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T{sub 1}-weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T{sub 1}-weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T{sub 2}*-effects) in the urine. T{sub 1}-weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T{sub 1}-weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in

  7. Measurement of lung tumor motion using respiration-correlated CT

    International Nuclear Information System (INIS)

    Mageras, Gig S.; Pevsner, Alex; Yorke, Ellen D.; Rosenzweig, Kenneth E.; Ford, Eric C.; Hertanto, Agung; Larson, Steven M.; Lovelock, D. Michael; Erdi, Yusuf E.; Nehmeh, Sadek A.; Humm, John L.; Ling, C. Clifton

    2004-01-01

    Purpose: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. Methods and materials: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. Results: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3

  8. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  9. WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

    International Nuclear Information System (INIS)

    Ouadah, S; Jacobson, M; Stayman, JW; Siewerdsen, JH; Ehtiati, T

    2016-01-01

    Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p 0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every acquisition. Research supported by National Institutes of Health Grant No. R01-EB-017226 and academic

  10. Kyphoplasty and vertebroplasty for spinal trauma; Kyphoplastie und Vertebroplastie bei Wirbelsaeulentraumata

    Energy Technology Data Exchange (ETDEWEB)

    Ahlhelm, F. [Kantonsspital Baden AG, Abteilung fuer Neuroradiologie, Institut fuer Radiologie, Baden (Switzerland); Omidi, R. [Kantonsspital Baden AG, Interventionelle Radiologie, Institut fuer Radiologie, Baden (Switzerland)

    2016-08-15

    Minimally invasive treatment of spinal fractures. Conservative treatment versus spinal surgery. Minimally invasive stabilization techniques, such as percutaneous (assisted) cementoplasty have been introduced as new procedures. Magnetic resonance imaging (MRI), X-rays and computed tomography (CT) are the imaging techniques of first choice. The most important questions concern recent fractures, instability and indications for minimally invasive treatment. Vertebroplasty and kyphoplasty are established methods for the treatment of patients with osteoporosis. Cementoplasty techniques are promising treatment options for traumatic spinal injuries. The application of the techniques should best be carried out in individual cases within the framework of prospective controlled studies. (orig.) [German] Minimal-invasive Behandlung von Wirbelsaeulentraumata. Konservative Behandlung vs. Wirbelsaeulenchirurgie. Als neue Verfahren wurden minimal-invasive Stabilisationstechniken, z. B. perkutane (assistierte) Zementoplastien eingefuehrt. Roentgen, MRT und CT sind die bildgebenden Verfahren der ersten Wahl. Die wichtigsten Fragestellungen sind: Frische Fraktur? Instabilitaet? Indikation fuer minimal-invasive Behandlung ?Vertebroplastie und Kyphoplastie sind bei Osteoporosepatienten etabliert. Bei Wirbelsaeulentraumata sind Zementoplastietechniken vielversprechende Therapieoptionen. Die Anwendung der Techniken sollte im individuellen Fall am besten im Rahmen prospektiver kontrollierter Studien erfolgen. (orig.)

  11. Significance of findings of both emergency chest X-ray and thoracic computed tomography routinely performed at the emergency unit in 102 polytrauma patients. A prospective study; Relevanz der Befunde von Thoraxroentgen und Thorax-CT im routinemaessigen Schockraumeinsatz bei 102 polytraumatisierten Patienten. Eine prospektive Studie

    Energy Technology Data Exchange (ETDEWEB)

    Grieser, T.; Buehne, K.H.; Haeuser, H.; Bohndorf, K. [Zentralklinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2001-01-01

    -Thoraxuebersicht (Roe-Tx) zusaetzliche Befunde zeigen kann, die von therapeutischer Relevanz sind. Patienten und Methodik: Bei 102 konsekutiven polytraumatisierten, aber haemodynamisch stabilen Patienten (Durchschnittsalter 41,2 Jahre, Altersbereich 12 bis 93 Jahre) wurden gemaess eines festgelegten Protokolls ein Roe-Tx und eine Tx-CT durchgefuehrt. Therapierelevante Befunde und die konsekutiv vom Traumateam veranlassten dringlichen Interventionen wurden in einem standardisiertem Erfassungsbogen dokumentiert. Als therapierelevant wurde jede Aenderung oder Ergaenzung im Management des Polytraumapatienten gewertet, die von der allgemein ueblichen Basistherapie abwich und dringliche Eingriffe im Schockraum oder im OP bzw. im Angiographieraum notwendig machten. Ergebnisse: 43 von 102 Patienten (42,2%) hatten insgesamt 51 therapierelevante Befunde. Der Roe-Tx allein ergab bei 23 Patienten (22,5%) 23 relevante Befunde (45,1%). Bei 7 dieser 23 Patienten (30,4%) zeigte das Tx-CT im Vergleich zu Roe-Tx noch weitere therapierelevante Ergebnisse. Das Tx-CT allein identifizierte 22 neue therapierelevante Befunde (43,2% bei 20 Patienten, 46,5%). Insgesamt zeigte das Tx-CT 30 relevante Befunde bei 27 Patienten, so dass 26,5% aller 102 Polytraumapatienten vom Tx-CT profitierten. Haeufigstes therapierelevantes Ergebnis stellte die Thoraxdrainageanlage dar (n=29). Zusammenfassung: Haemo-dynamisch stabile polytraumatisierte Patienten profitieren von der Durchfuehrung des Tx-CT bezueglich der Detektion therapierelevanter thorakaler Verletzungen bzw. der Kontrolle fruehzeitig erfolgter therapeutischer Interventionen. Dennoch sollte der Roe-Tx aufgrund seiner unuebertroffenen schnellen Durchfuehr- und Verfuegbarkeit auch weiterhin die primaere Screening-Methode der Wahl bleiben. (orig.)

  12. Availability of perfluoroctylbromide (PFOB) emulsion used as agent in the liver tumor imaging of computed tomography (CT)

    International Nuclear Information System (INIS)

    Ozawa, Takachika

    1986-01-01

    We carried out a fundamental study on the availability of perfluoroctylbromide (PFOB) emulsion used as an agent in the liver tumor imaging of computed tomography (CT). For this study, we used emulsified yolk phospolipid as a surfactant for PFOB emulsion because it is generally considered to have higher safety relative to the administration to the humans. In the rabbits' liver tumor model in which VX 2 tumor cell was implanted into their livers, we observed increases in the CT values of the livers when 5 to 10 ml/kg of PFOB emulsion (20 % w/v) was administered into the vein, and also ringlike enhancement and increases in the CT values on the tumor rim when 20 ml/kg of PFOB emulsion was administered. In addition, in the chemical analysis of a gas chromatography, we also observed significant increases in the PFOB concentration on the tumor rim, compared with those of normal liver parenchyma, when 20 ml/kg of PFOB emulsion was given. In the finding of CT values in the human liver tumor by means of organ perfusion system, we recognized increases in the CT values (induced by the accumulation of PFOB emulsion) on the rim of the metastatic tumor of colon cancer. These results suggest that PFOB emulsion has certain availability as an agent for the liver tumor imaging of computed tomography (CT). (author)

  13. Informed consent in contrast-enhanced CT. Understanding of risks and identification of possible prognostic factors; Patientenaufklaerung bei kontrastmittelgestuetzter CT. Risikoverstaendnis und Identifikation moeglicher Prognosefaktoren

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, S.; Dendl, L.M.; Scharf, G.; Stroszczynski, C.; Schreyer, A.G. [University Medical Center Regensburg (Germany). Dept. of Radiology; Zeman, F. [University Medical Center Regensburg (Germany). Center for Clinical Studies

    2015-11-15

    Aim of our study was to assess understanding of risks associated with intravascular application of contrast media in patients undergoing CT examination. We wanted to evaluate epidemiologic and socio-economic prognostic factors for a higher understanding of risks. Additionally, we evaluated a possible correlation between an extensive, outcome-oriented oral informed consent and better understanding of risks. 120 patients distributed in 2 study arms participated in this prospective study. In study arm I, the treating physician was not informed that his patients participated in a study whereas the physician in study arm II knew about the survey. After the informed consent we performed a standardized, semi-structured interview to enquire the 3 most frequent risks of intravascular application of contrast agents (anaphylactoid reactions, nephropathy and thyrotoxic crisis) and epidemiologic data. The understanding of the risks was evaluated using a 6 point scale. Patients scored 3.73 points in study arm I and 4.93 points in arm II on average. The statistical difference between both study arms was highly significant (p < 0.001). In a combined logistic regression analysis, only ''higher education'' (p = 0.001) and participation in study arm II (p =0.001) showed a significant connection to a better understanding of risks. Patients profit from an outcome-oriented and individualized informed consent. Due to the significant correlation between educational level and understanding of risks, informed consent should be adjusted to the educational status of the individual patient, e.g. by using didactic aids or individualized information sheets.

  14. CT morphology of benign median nerve tumors; Report of three cases and a review

    Energy Technology Data Exchange (ETDEWEB)

    Feyerabend, T; Schmitt, R; Lanz, U; Warmuth-Metz, M [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Roentgendiagnostik Wuerzburg Univ. (Germany, F.R.). Abt. fuer Hand- und Mikrochirurgie

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.).

  15. A Prospective Comparison of 18F-FDG PET/CT and CT as Diagnostic Tools to Identify the Primary Tumor Site in Patients with Extracervical Carcinoma of Unknown Primary Site

    DEFF Research Database (Denmark)

    Moller, Anne Kirstine H; Loft, Annika; Berthelsen, Anne K

    2012-01-01

    that the same set of criteria were used for classification of patients, that is, either as CUP patients or patients with a suggested primary tumor site. The independently obtained suggestions of primary tumor sites using PET/CT and CT were correlated with the SR to reach a consensus regarding true-positive (TP......), true-negative, false-negative, and false-positive results.Results. SR identified a primary tumor site in 66 CUP patients (48.9%). PET/CT identified 38 TP primary tumor sites and CT identified 43 TP primary tumor sites. No statistically significant differences were observed between (18)F-FDG PET...

  16. Diagnosis of tumors of the pituitary region by two-plane CT scans

    International Nuclear Information System (INIS)

    Murata, Minoru; Inoue, Hiroshi; Misumi, Shuzo; Shimizu, Tsuneo; Tamura, Masaru

    1981-01-01

    Thirty five cases of tumors in the pituitary region were analysed by two-plane CT (ordinary sections and reverse sections) in order to obtain a more accurate image of the tumor and thus establish an appropriate indication for the subnasal transsphenoidal approach. The tumors of pituitary region were classified into six groups (types I-VI) according to their degree of extension and direction of growth. Small tumors such as types I and II were detected more clearly by the reverse section than by the ordinary section. In cases of large tumors (types III-VI) relation of the tumor to the surrounding structures such as the sphenoid sinus, third ventricle, lateral ventricule, middle fossa and brain stem was accurately demonstrated by the reverse section. In the differential diagnosis of tumors in the pituitary regions, tumors showing mixed density or slightly high density and widening of the anteroposterior diameter of the sella in the precontrast reverse section and homogeneous enhancement by infusion were likely to be pituitary adenomas. One third of the pituitary adenomas showed ring-like high density in the post-contrast reverse section. Calcification was not seen in the pituitary adenomas by CT scans. All craniopharyngiomas belonged to types III-VI. Craniopharyngiomas showed high and/or low density, and various degrees of calcification in plain CT scans. Ring-like high density was seen in two thirds of the craniopharyngiomas. About one third of the craniopharyngiomas showed widening of the antero-posterior diameter of the sella. (J.P.N.)

  17. CT and MR findings of primitive neuroectodermal tumor

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Kim, In One; Chang, Kee Hyun; Han, Moon Hee; Cho, Byung Kyu

    1991-01-01

    Cerebral primitive neuroectodermal tumor (PNET), consisting of undifferentiated primitive cells, is a neoplasm of children and young adults that occurs predominantly in the supratentorial compartment. In this report, we retrospectively reviewed and analyzed 18 CT and 6 MR findings in 18 patients with pathologically-proven PNET to discover the characteristic findings, if may. The most characteristic feature of the PNETs was a well-defined multilobular oval or round large mass with components of peripheral cystic change or calcification in the cerebral hemisphere, especially in the parietal lobe. Usually there was only minimal surrounding edema. The CT density of the tumor was iso - or slightly high density with homogeneous contrast enhancement in the solid portion and low density in the cystic area. MR findings demonstrated iso - signal intensity on both T1 - weighted (T1WI) and T2-weighted (T2WI) images and dense enhancement in the solid element. The cystic portion revealed low intensity on T1WI and high intensity on T2WI

  18. Missed causative tumors in diagnosing tumor-induced osteomalacia with (18)F-FDG PET/CT: a potential pitfall of standard-field imaging.

    Science.gov (United States)

    Kaneuchi, Yoichi; Hakozaki, Michiyuki; Yamada, Hitoshi; Hasegawa, Osamu; Tajino, Takahiro; Konno, Shinichi

    2016-01-01

    We describe herein two tumor-induced osteomalacia (TIO) cases for whom the causative lesions, located in their popliteal fossa, that were not identified in the standard field of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT), which usually images only the head, trunk, and proximal parts of the extremities. A 47 years old Japanese man with multiple pathological fractures due to osteomalacia, accompanied by muscle weakness, hypophosphatemia, and an elevation of alkaline phosphatase (ALP) was referred to our hospital. A (18)F-FDG PET/CT scan was performed, but no (18)F-FDG uptake was detected in the standard field of imaging. Magnetic resonance imaging revealed a small subcutaneous tumor (1.9×1.2×0.6cm) of the left posteriomedial knee, displaying uniform enhancement on gadolinium-enhanced T1-weighted fat-suppression imaging. The tumor was resected widely and diagnosed as phosphaturic mesenchymal tumor, mixed connective tissue variant (PMTMCT). The other patient was a 31 years old Japanese woman with multiple pathological fractures, hypophosphatemia and elevated of ALP and was referred to our hospital on suspicion of TIO. Although the causative lesion was not identified in the standard field of (18)F-FDG PET/CT, (18)F-FDG uptake (SUVmax 2.9) was detected on the right knee in the additional whole-body (18)F-FDG PET/CT. Magnetic resonance imaging revealed a soft-tissue tumor (6.4×4.1×2.9cm) in the right posterior knee. Following biopsy, the tumor was marginally resected, and was pathologically diagnosed as PMTMCT. Once patients are suspected to have TIO, a whole-body nuclear imaging study such as (18)F-FDG PET/CT should be performed, in order not to miss the hidden causative tumor, especially occurring in the distal extremities.

  19. Bronchial carcinoid tumor: helical CT and virtual bronchoscopy

    International Nuclear Information System (INIS)

    Diez, Eduardo; Carrascosa, Patricia; Capunay, Carlos; Spinozzi, German; Abramson, Horacio; Berna, Miguel

    2001-01-01

    The authors reported a case of a 61 years old man with recurrent neumonia of the inferior right lobe diagnosed by a chest radiography. A complementary helical CT showed an endobronquial mass on the right intermediate bronchus. Virtual bronchoscopy contributed to a better definition of this lesion, confirmed by a real bronchoscopy. The lesion was diagnosed as a carcinoid tumor by a bronchial biopsy. After surgery (sleeve resection of the tumor) the patient did not show any recurrence of his broncho-neumonic clinical features. (author)

  20. 18F-FDG PET/CT-based gross tumor volume definition for radiotherapy in head and neck Cancer: a correlation study between suitable uptake value threshold and tumor parameters

    International Nuclear Information System (INIS)

    Kao, Chia-Hung; Hsieh, Te-Chun; Yu, Chun-Yen; Yen, Kuo-Yang; Yang, Shih-Neng; Wang, Yao-Ching; Liang, Ji-An; Chien, Chun-Ru; Chen, Shang-Wen

    2010-01-01

    To define a suitable threshold setting for gross tumor volume (GTV) when using 18 Fluoro-deoxyglucose positron emission tomography and computed tomogram (PET/CT) for radiotherapy planning in head and neck cancer (HNC). Fifteen HNC patients prospectively received PET/CT simulation for their radiation treatment planning. Biological target volume (BTV) was derived from PET/CT-based GTV of the primary tumor. The BTVs were defined as the isodensity volumes when adjusting different percentage of the maximal standardized uptake value (SUVmax), excluding any artifact from surrounding normal tissues. CT-based primary GTV (C-pGTV) that had been previously defined by radiation oncologists was compared with the BTV. Suitable threshold level (sTL) could be determined when BTV value and its morphology using a certain threshold level was observed to be the best fitness of the C-pGTV. Suitable standardized uptake value (sSUV) was calculated as the sTL multiplied by the SUVmax. Our result demonstrated no single sTL or sSUV method could achieve an optimized volumetric match with the C-pGTV. The sTL was 13% to 27% (mean, 19%), whereas the sSUV was 1.64 to 3.98 (mean, 2.46). The sTL was inversely correlated with the SUVmax [sTL = -0.1004 Ln (SUVmax) + 0.4464; R 2 = 0.81]. The sSUV showed a linear correlation with the SUVmax (sSUV = 0.0842 SUVmax + 1.248; R 2 = 0.89). The sTL was not associated with the value of C-pGTVs. In PET/CT-based BTV for HNC, a suitable threshold or SUV level can be established by correlating with SUVmax rather than using a fixed threshold

  1. Molecular imaging of neuroendocrine tumors using 68Ga-labeled peptides (Somatostatin receptor PET/CT)

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.; Hoersch, D.

    2009-01-01

    Receptor PET/CT using 68 Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The 68 Ge/ 68 Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for 68 Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the 68 Ga generator could play a similar important role for PET/CT as did the 99m Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  2. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    International Nuclear Information System (INIS)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso; Kuruoshi, Marcia Etsuko

    2009-01-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  3. Value of 18F-FDG PET/CT Combined With Tumor Markers in the Evaluation of Ascites.

    Science.gov (United States)

    Han, Na; Sun, Xun; Qin, Chunxia; Hassan Bakari, Khamis; Wu, Zhijian; Zhang, Yongxue; Lan, Xiaoli

    2018-05-01

    The purpose of this study is to investigate the value of 18 F-FDG PET/CT combined with assessment of tumor markers in serum or ascites for the diagnosing and determining the prognosis of benign and malignant ascites. Patients with ascites of unknown cause who underwent evaluation with FDG PET/CT were included in this retrospective study. The maximum standardized uptake value (SUV max ) and levels of the tumor markers carbohydrate antigen-125 (CA-125) and carcinoembryonic antigen (CEA) in serum and ascites were recorded. The diagnostic values of FDG PET/CT, CEA and CA-125 levels in serum or ascites, and the combination of imaging plus tumor marker assessment were evaluated. Factors that were predictive of survival were also analyzed. A total of 177 patients were included. Malignant ascites was eventually diagnosed in 104 patients, and benign ascites was diagnosed in the remaining 73 patients. With the use of FDG PET/CT, 44 patients (42.3%) were found to have primary tumors. The sensitivity, specificity, and accuracy of FDG PET/CT were 92.3%, 83.6%, and 88.7%, respectively. CA-125 levels in serum and ascites showed much better sensitivity than did CEA levels, but they showed significantly lower specificity. If the combination of tumor markers and FDG PET/CT was analyzed, the sensitivity, specificity, and accuracy of tumor markers in serum were 96.6%, 78.1%, and 88.7%, and those of tumor markers in ascites were 97.7%, 80.0%, and 90.4%, respectively. Sex may be an important factor affecting survival time (hazard ratio, 0.471; p = 0.004), but age, CEA level, and FDG PET/CT findings could not predict survival. FDG PET/CT combined with assessment of tumor markers, especially CEA, increased the efficacy of diagnosis of ascites of unknown causes. Male sex conferred a poorer prognosis, whereas age, CEA level, and FDG uptake had no predictive significance in patients with malignant ascites.

  4. The performance and application of 18F-FDG PET/CT in diagnosis of tumor

    International Nuclear Information System (INIS)

    Wang Junqi

    2004-01-01

    Positron emission tomography (PET)/computed tomography (CT) inline scanner combined with high performance PET and CT have been introduced to clinical in recent years. The application of PET/CT in oncology are rapid increasing. The addition of CT to PET offers many advantages, including obtaining a fast and relatively accurate transmission map, shortening the duration of the examination, adding precise anatomical information to PET imaging, and providing additional diagnostic information. However, using CT for attenuation correction can led to some artifacts; quantitative measurements may be altered, high density IV and oral metallic objects may produce artifacts, and the registration of PET and CT may occasionally suboptimal. In head and neck tumor PET/CT offers particular potential advantages as well as abdomen and pelvic tumor. Even in the thorax, which the physical movement may produce unsatisfactory results, offers some advantages also. Preliminary results of PET/CT over PET or CT in oncology are very encouraging. It is clear the PET/CT fusion technology has an more and more impact on both diagnostic and therapeutic aspects of patient management

  5. Combined functional and morphological imaging of sarcomas. Significance for diagnostics and therapy monitoring; Kombinierte funktionelle und morphologische Bildgebung bei Sarkomen. Stellenwert fuer Diagnostik und Therapiemonitoring

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, N.; Rist, C.; Reiser, M.F.; Berger, F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Schlemmer, M.; Issels, R. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Medizinische Klinik und Poliklinik III, Muenchen (Germany)

    2010-04-15

    . Ein Staging von Sarkompatienten einschliesslich der Erfassung von Lungenmetastasen ist damit in einem Untersuchungsgang moeglich. Die PET/CT wird bei Patienten mit primaer ossaeren und Weichteilsarkomen zur Diagnosestellung, zum Staging und Restaging, zum ''metabolischen Tumorgrading'', zur Biopsieplanung, zum Rezidivnachweis sowie zum Therapiemonitoring eingesetzt. Es konnte gezeigt werden, dass der FDG-Uptake des Tumors vor Therapie sowie die Aenderungen im FDG-Uptake nach Therapie signifikant mit der histopathologischen Response und dem Ueberleben der Patienten korrelieren. Damit ermoeglichen PET und PET/CT auch prognostische Aussagen. Neue Perspektiven der Hybridbildgebung mit der PET/CT ergeben sich durch die Etablierung neuer Radiotracer sowie durch die kombinierte Untersuchung von Tumormetabolismus und -perfusion. Die hochaufloesende MRT bleibt fuer die lokale Primaerdiagnostik sowie zur praeoperativen Planung mit Klaerung der exakten anatomischen Situation und moeglicher Infiltration vaskulaerer oder nervaler Strukturen weiter unverzichtbar. Die kontrastverstaerkte MRT ist ein wichtiges und gut verfuegbares Alternativverfahren zur Rezidivdiagnostik, ganz besonders fuer nichthypermetabole Tumoren. Dynamische, kontrastverstaerkte MRT-Sequenzen gewinnen fuer das Therapiemonitoring zunehmend an Bedeutung und sollten in prospektiven Studien mit der FDG-PET/CT korreliert werden. (orig.)

  6. Functioning islet cell tumor of the pancreas. Localization with dynamic spiral CT

    International Nuclear Information System (INIS)

    Chung, M.J.; Choi, B.I.; Han, J.K.; Chung, J.W.; Han, M.C.; Bae, S.H.

    1997-01-01

    Purpose: The purpose of this study was to evaluate the usefulness of dynamic spiral CT, including multidimensional reformation, in the detection and localization of islet cell tumors of the pancreas. Material and Methods: Seven patients with histopathologically proven functioning islet cell tumors of the pancreas were studied with 2-phase contrast-enhanced spiral CT. Scanning of the arterial phase and late phase was started 30 s and 180 s, respectively, after injection of 100 ml of contrast medium at a rate of 3 ml/s. Results: Axial images in the arterial phase depicted the lesions in 5 patients, but in the late phase in only one patient. Multiplanar reformatted images of the arterial phase depicted the lesions in all 7 patients. Maximal intensity projection images demonstrated all lesions with information of their relationship to the vascular structure. Conclusion: Dynamic spiral CT with scanning during the arterial phase and retrospective multidimensional reformation is useful for preoperative detection and localization of small islet cell tumors of the pancreas. (orig.)

  7. Contrast-enhanced helical CT of the pancreas. Optimal timing of imaging for pancreatic tumor evaluation

    International Nuclear Information System (INIS)

    Koide, Kazuki; Sekiguchi, Ryuzo

    2001-01-01

    We performed three-phase helical CT in patients suspected pancreatic tumors and investigated the optimal timing of imaging for evaluation of the pancreatic mass. The pancreatic-phase was superior in detecting pancreatic tumors, including islet cell tumors that may show strong enhancement. However, portal vein-phase imaging was also superior in 16.7% of our patients. Taking into account examination for hepatic metastasis, helical CT of any pancreatic tumor should include images obtained in the pancreatic and portal vein phases. (author)

  8. Comparison of F-18-FDG PET/CT findings between pancreatic solid pseudopapillary tumor and pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Kim, Yong-il; Kim, Seok-ki; Paeng, Jin Chul; Lee, Ho-Young

    2014-01-01

    Objective: Pancreatic solid pseudopapillary tumor (SPT) is a rare benign tumor. Little data are available on positron emission tomographic/computed tomographic (PET/CT) characteristics of this tumor. Therefore, we analyzed the metabolic characteristics of SPT using F-18-FDG PET/CT and compared the results with those of pancreatic ductal adenocarcinoma. Methods: We retrospectively reviewed the records of 11 SPT patients and 46 patients with ductal adenocarcinoma. Ten SPT patients had primary tumors and 1 patient had metastatic SPT. Maximum standardized uptake value (max SUV), mean SUV, metabolic tumor volume (MTV), total lesion glycolysis (TLG), and tumor-to-background ratio (TBR) were evaluated. Mann–Whitney U test between pancreatic SPT and ductal adenocarcinoma was performed. In addition, age, gender and tumor size-adjusted analysis of covariance (ANCOVA) was done between pancreatic SPT and ductal adenocarcinoma. Results: Compared with pancreatic ductal adenocarcinomas, SPTs had significantly higher tumor size-adjusted MTV and TLG. MTV and TLG values were significantly correlated with T-stage of the SPTs. In 1 SPT patient, metastases in the liver and mesentery were revealed by intense uptake of FDG on F-18-FDG PET/CT, and after PET/CT had suggested the presence of pancreatic SPT. Conclusion: We recommend that SPT be considered when a solid pancreatic mass with increased FDG metabolism is encountered on PET/CT. F-18-FDG PET/CT may be useful in detecting subtle metastases of SPT

  9. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    International Nuclear Information System (INIS)

    Chen Yang; Shi Luyao; Shu Huazhong; Luo Limin; Coatrieux, Jean-Louis; Yin Xindao; Toumoulin, Christine

    2013-01-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors. (paper)

  10. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  11. Ga-68-DOTA-TATE PET/CT for discrimination of tumors of the optic pathway.

    Science.gov (United States)

    Klingenstein, Annemarie; Haug, Alexander R; Miller, Christina; Hintschich, Christoph

    2015-02-01

    Symptomatic tumors of the optic nerve pathway may endanger vision. They are difficult to classify by imaging alone and biopsy may damage visual function. Tumor pathology influences treatment decision and a diagnostic tool with a high sensitivity and specificity would therefore be invaluable. We hypothesized that Ga-68-DOTA-TATE PET/CT may help in discriminating optic nerve tumors as uptake of somatostatin is elevated in meningiomas. Ga-68-DOTA-TATE PET/CT was used to examine 13 patients with ambiguous, symptomatic lesions of the optic pathway for treatment planning. The presence or absence of meningioma was validated by histopathology or supplementary diagnostic work-up. Ga-68-DOTA-TATE PET/CT identified 10 meningiomas (en plaque = 1, optic nerve sheath = 4, sphenoidal = 5) correctly via increased SSTR (somatostatin receptor) expression (mean SUVmax (maximum standardized uptake value) = 14.3 ± 15.4). 3 tumors did not show elevated Ga-68-DOTA-TATE uptake (SUVmax = 2.1 ± 1.0). Subsumizing all clinical-radiological follow-up tools available, these lesions were classified as an intracerebral metastasis of an advanced gastric carcinoma, histologically proven inflammatory collagenous connective tissue and presumed leukemic infiltration of a newly diagnosed chronic lymphocytic leukemia. In this case series, Ga-68-DOTA-TATE PET/CT demonstrated both a sensitivity and specificity of 100%. Yet, the golden standard of histopathology was only available in a subset of patients included. Ga-68-DOTA-TATE PET/CT proved to be a valuable diagnostic tool for the correct classification of equivocal, symptomatic tumors of the anterior optic pathway requiring therapy. PET/CT results influenced therapy decision essentially in all cases.

  12. Interobserver and Intraobserver Variability among Measurements of FDG PET/CT Parameters in Pulmonary Tumors

    Directory of Open Access Journals (Sweden)

    Gülgün Büyükdereli

    2016-06-01

    Full Text Available Background: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring.: 18F-fluorodeoxyglucose (FDG positron emission tomography computed tomography (PET/CT provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT, maximum SUV (SUVmax, mean SUV (SUVmean and maximum SUV normalized to liver mean SUV (SUVnliv max were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm. Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.

  13. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  14. Evaluation of gross tumor size using CT, 18F-FDG PET, integrated 18F-FDG PET/CT and pathological analysis in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yu Huiming; Liu Yunfang; Hou Ming; Liu Jie; Li Xiaonan; Yu Jinming

    2009-01-01

    Purpose: The correlation of gross tumor sizes between combined 18 F-FDG PET/CT images and macroscopic surgical samples has not yet been studied in detail. In the present study, we compared CT, 18 F-FDG PET and combined 18 F-FDG PET/CT for the delineation of gross tumor volume (GTV) and validated the results through examination of the macroscopic surgical specimen. Methods: Fifty-two operable non-small cell lung cancer (NSCLC) patients had integrated 18 F-FDG PET/CT scans preoperatively and pathological examination post-operation. Four separate maximal tumor sizes at X (lateral direction), Y (ventro-dorsal direction) and Z (cranio-caudal direction) axis were measured on 18 F-FDG PET, CT, combined 18 F-FDG PET/CT and surgical specimen, respectively. Linear regression was calculated for each of the three imaging measurements versus pathological measurement. Results: No significant differences were observed among the tumor sizes measured by three images and pathological method. Compared with pathological measurement, CT size at X, Y, Z axis was larger, whereas combined 18 F-FDG PET/CT and 18 F-FDG PET size were smaller. Combined 18 F-FDG PET/CT size was more similar to the pathological size than that of 18 F-FDG PET or CT. Results of linear regressions showed that integrated 18 F-FDG PET/CT was the most accurate modality in measuring the size of cancer. Conclusions: 18 F-FDG PET/CT correlates more faithfully with pathological findings than 18 F-FDG PET or CT. Integrated 18 F-FDG PET/CT is an effective tool to define the target of GTV in radiotherapy.

  15. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D)

    International Nuclear Information System (INIS)

    Rock, C.; Kotsianos, D.; Linsenmaier, U.; Fischer, T.

    2002-01-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [de

  16. Dynamic contrast-enhanced CT in advanced lung cancer after chemotherapy with/within radiation therapy: Can it predict treatment responsiveness of the tumor?

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Mi Ri; Whang, Sung Ho; Park, Chul Hwan; Kim, Sang Jin; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the contrast enhancement patterns of lung cancer after chemotherapy using a dynamic contrast-enhanced (DCE) CT and to determine whether the enhancement patterns of tumors at early stages of treatment can predict treatment responses. Forty-two patients with advanced lung cancers underwent DCE-CT and follow-up CT after chemotherapy. We evaluated peak and net enhancement (PE and NE, respectively) and time-density curves (TDCs) (type A, B, C, and D) on DCE-CT images. Treatment responses were evaluated using revised Response Evaluation Criteria in Solid Tumor criteria. NE and PE values were significantly higher in the progressive disease (PD) groups than in the stable disease (SD) or partial response (PR) groups (p < 0.05). Types B, C, and D on TDCs were observed mostly in the PR and SD groups (96.0%), whereas type A was most frequent in the SD and PD groups (97.2%), which were significantly different in terms of PE and NE. Contrast enhancement pattern regarding the response of treatment on DCE-CT images could be helpful in predicting treatment response of advanced lung cancer after treatment.

  17. CT diagnosis of sellar and juxtasellar lesions, 3. Non-tumorous lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tatsuya [Nagoya Univ. (Japan). Faculty of Medicine

    1982-08-01

    A study is made of the usefulness and limitations of the CT diagnosis of sellar and juxtasellar lesions other than tumors. This study is based on 112 verified cases at Nagoya University Hospital from October, 1976, to December, 1981. The lesions included in this study are classified into four groups: vascular, inflammatory, traumatic lesion, and congenital anomaly. Although cerebral angiography is the cardinal method for the diagnosis of vascular lesions, CT is useful for the evaluation of a giant aneurysm, the localization of bleeding, or infarction by a ruptured aneurysm. Radiation brain necrosis, a special form of vascular lesion, can also be diagnosed if the critical analysis is made after previous irradiation. CT findings are helpful for the local diagnosis of acute inflammatory lesions, such as basal meningitis or abscess, but specific diagnosis is made on the basis of clinical signs and CSF study. Abnormal CT findings are obtained from a chronic inflammatory process, such as arachnoiditis adhesiva, glanuloma, or mucocele. Differential diagnosis is necessary with brain tumors. The CT findings of an arachnoid cyst are often diagnostic. Metrizamide or air cisternography, either combined with CT or without it, is important for the diagnosis of basal meningoencephalocele and hypothalamic hamaroma. Pneumocephalus and an intracranial foreign body resulting from a head injury can be diagnosed by plain skull and CT. The diagnosis of CSF leakage or prolapse cerebri associated with a skull-base fracture has been most difficult, but even it is possible by a combination of polytomography and high-resolution CT with metrizamide cisternography.

  18. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    International Nuclear Information System (INIS)

    Lu, W; Wang, J; Zhang, H

    2015-01-01

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  19. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lu, W; Wang, J; Zhang, H [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  20. Automatic computer aided analysis algorithms and system for adrenal tumors on CT images.

    Science.gov (United States)

    Chai, Hanchao; Guo, Yi; Wang, Yuanyuan; Zhou, Guohui

    2017-12-04

    The adrenal tumor will disturb the secreting function of adrenocortical cells, leading to many diseases. Different kinds of adrenal tumors require different therapeutic schedules. In the practical diagnosis, it highly relies on the doctor's experience to judge the tumor type by reading the hundreds of CT images. This paper proposed an automatic computer aided analysis method for adrenal tumors detection and classification. It consisted of the automatic segmentation algorithms, the feature extraction and the classification algorithms. These algorithms were then integrated into a system and conducted on the graphic interface by using MATLAB Graphic user interface (GUI). The accuracy of the automatic computer aided segmentation and classification reached 90% on 436 CT images. The experiments proved the stability and reliability of this automatic computer aided analytic system.

  1. Analysis of the manifestation and feature of adrenal tumor on CT in 30 cases

    International Nuclear Information System (INIS)

    Xi Riquan; Xie Daohai; Guo Liang; Hu Chunhong; Fu Yingdi

    2001-01-01

    Objective: To analyze the manifestation and the feature of adrenal tumor with CT. Methods: The findings of various adrenal tumors with CT in 30 cases were analyzed retrospectively, the key to the diagnosis and differential diagnosis was suggested. Results: Usually, fibroxanthoma is inhomogeneous in density and moderate in size and was enhanced slightly after contrast medium administration. Pheochromocytoma is always larger and inhomogeneous in density and was enhanced markedly. The CT unit of myelo-lipoma simulated those of fluid or fat. Adrenal cyst has a low CT value and it showed cystic wall calcification. Aldosteronism adenoma was low in density and small in size, while cortisol adenoma was moderate in density and medium in size. Adrenocortical adenocarcinoma was the larger one with irregular margin and irregular hypodense areas inside. Metastatic carcinoma was larger and inhomogeneous in density. Conclusion: It is possible to increase the diagnostic rate by analysing the imaging feature of adrenal tumor

  2. 18F-Fluoride PET/CT tumor burden quantification predicts survival in breast cancer.

    Science.gov (United States)

    Brito, Ana E; Santos, Allan; Sasse, André Deeke; Cabello, Cesar; Oliveira, Paulo; Mosci, Camila; Souza, Tiago; Amorim, Barbara; Lima, Mariana; Ramos, Celso D; Etchebehere, Elba

    2017-05-30

    In bone-metastatic breast cancer patients, there are no current imaging biomarkers to identify which patients have worst prognosis. The purpose of our study was to investigate if skeletal tumor burden determined by 18F-Fluoride PET/CT correlates with clinical outcomes and may help define prognosis throughout the course of the disease. Bone metastases were present in 49 patients. On multivariable analysis, skeletal tumor burden was significantly and independently associated with overall survival (p breast cancer patients (40 for primary staging and the remainder for restaging after therapy). Clinical parameters, primary tumor characteristics and skeletal tumor burden were correlated to overall survival, progression free-survival and time to bone event. The median follow-up time was 19.5 months. 18F-Fluoride PET/CT skeletal tumor burden is a strong independent prognostic imaging biomarker in breast cancer patients.

  3. Radiological diagnostics of malignant tumors of the musculoskeletal system in childhood and adolescence; Radiologische Diagnostik maligner Tumoren des Muskuloskelettalsystems im Kindes- und Adoleszentenalter

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, S.F.; Krestan, C.R. [Medizinische Universitaet Wien, Klinische Abteilung fuer Neuroradiologie und muskuloskelettale Radiologie, Wien (Austria); Hojreh, A.; Hoermann, M. [Medizinische Universitaet Wien, Klinische Abteilung fuer Allgemeine Radiologie und Kinderradiologie, Wien (Austria)

    2008-10-15

    Rhabdomyosarcoma, osteosarcoma and Ewing's sarcoma are the most common malignant tumors of the musculoskeletal system in childhood and adolescence representing about 10% of newly diagnosed cancers in children and adolescents. In the last two decades the prognosis of patients with such malignancies improved significantly. On the one hand because of the advances in chemotherapy and orthopedic surgery, on the other hand also because of the innovations in radiological diagnostics. The precise pre-therapeutical staging of tumors of the musculoskeletal system provides important prognostic information and has impact on the entire therapy management. During respectively after therapy, imaging is extremely important in the follow-up and in diagnosing a possible recurrent disease. Modern imaging diagnostics of musculoskeletal tumors basically consist of conventional X-ray, of computed tomography (CT) and magnetic resonance imaging (MRI), and of modalities of nuclear medicine such as szintigraphy, positron emission tomography (PET) and PET CT. (orig.) [German] Das Rhabdomyosarkom, das Osteosarkom und das Ewing-Sarkom sind die am haeufigsten auftretenden malignen Tumoren des Muskuloskelettalsystems im Kindes- und Adoleszentenalter. Diese Erkrankungen repraesentieren etwa 10% der bei Kindern und Jugendlichen neu diagnostizierten Tumoren. In den letzten beiden Jahrzehnten hat sich insgesamt die Prognose der Patienten mit solchen Malignomen deutlich gebessert. Einerseits aufgrund der Fortschritte in der Chemotherapie und orthopaedischen Tumorchirurgie, andererseits nicht zuletzt aufgrund der zahlreichen Innovationen der radiologischen Diagnostik. Das praezise praetherapeutische Staging von Tumoren des Muskuloskelettalsystems liefert wichtige prognostische Informationen und beeinflusst das gesamte Therapiemanagement. Waehrend bzw. nach erfolgter Therapie ist die Bildgebung ganz entscheidend im Follow-up und bei der Diagnostik einer moeglichen Rezidiverkrankung. Die moderne

  4. CT evaluation of gastric cancer. Depth of tumor invasion and pancreas invasion

    International Nuclear Information System (INIS)

    Banba, Yoshihisa; Kanazawa, Tadayoshi; Seto, Hikaru

    1998-01-01

    To compare the internal structure of tumor and the contiguous organ configuration on computed tomography (CT) with the depth of tumor invasion on the pathological specimen. Sixty-four gastric cancers depicted on incremental dynamic CT were classified according to the internal structure of the tumor, and correlated with the depth of tumor invasion. In addition, the cancers were classified according to the contiguous pancreatic configuration, and correlated with the degree of pancreatic invasion. Eleven tumors with thickened gastric wall consisting of both a thick inner layer of high attenuation and a thin outer layer of low attenuation (two-layered tumor with a thin outer layer) did not invade the serosa: mucosa (n=5) and submucosa (n=6). Of 59 gastric cancers with a regular margin to the contiguous pancreas, pancreatic invasion was absent in 58 and present in one. Pancreatic invasion was present in all of five gastric cancers with an irregular margin. Our results indicate that two-layered gastric tumors with a thin outer layer never invade the serosa. Furthermore, pancreatic invasion is predicted only when the margin of the contiguous pancreas is irregular. (author)

  5. Planungsunterstützung für Pankreasoperationen bei Hyperinsulinismus von Kindern

    Science.gov (United States)

    Dornheim, J.; Preim, B.; Preim, U.; Mohnike, K.; Blankenstein, O.; Füchtner, F.; Mohnike, W.; Empting, S.; Mohnike, K.

    Auf Basis von sechs PET/CT-Datensätzen des Pankreas wird eine Computerunterstützung für die Teilresektion der Bauchspeicheldr üse (Pankreas) bei fokalem Hyperinsulinismus von Kindern entwickelt. Ziel ist es, die Lokalisation des krankhaften Fokus im Pankreasgewebe präoperativ dreidimensional zu visualisieren, um so die Sicherheit des Eingriffs zu erhöhen. Die relevanten anatomischen Strukturen werden im CT segmentiert und anschließend dreidimensional visualisiert. Der im PET erkennbare Fokus wird in diese anatomische 3D-Visualisierung eingeblendet. Es zeigt sich eine klare Erkennbarkeit des Fokus in allen sechs Fällen.

  6. A clinical study of mucin producing tumor of pancreas with US and CT

    International Nuclear Information System (INIS)

    Suzuki, Tadashi; Imaizumi, Toshihide; Nakasako, Toshiaki; Hatori, Takashi; Takasaki, Ken

    1999-01-01

    We conclude that multilocular cysts are 3 cm and over, or elevated types as in mucin producing pancreatic tumors must be neoplasm in the pathological study. But, we question whether or not we can diagnose the elevated type before the operation. So, for the purpose of making a clear guideline of diagnosis for elevated types, we examined 46 operating cases of mucin producing tumors (Kuroda type I) documented from 1985 to 1994. We examined existence, height and properties of elevated lesions, 25 cases of elevated type and 21 cases of flat type. There is a significant difference of height with US and CT, and existence of enhancement with CT. As a result, we have obtained the following guidelines. The height of an elevated lesion with US is 4 mm and over, and the height of that with CT is 3 mm and over. It is enhanced with CT. Therefore, we find it possible to diagnose elevated types with US and CT. (author)

  7. Diagnosis of colorectal tumors; Diagnostik von kolorektalen Tumoren. Mehrschichtcomputertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Pegios, W.; Jacobi, V.; Schaefer, S.; Abolmaali, N.; Luboldt, W. [Institut fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Universitaet Frankfurt (Germany)

    2003-02-01

    With the introduction of multislice CT extensive volumetric data sets can be quickly acquired in high spatial resolution. The high spatial resolution reduces partial volume effects and enables multiplanar reconstructions. Regarding the colorectum this means that the colon can be assessed if the colon is sufficiently cleaned and distended, and that transmural infiltration of colorectal carcinoma and liver metastases can be better detected. T-staging of colon cancer is less important than T-staging of rectal cancer. Based on the higher contrast MRI is superior to CT in T-staging of rectal cancer and in the differentiation between scarring tissue and recurrence of carcinoma. (orig.) [German] Mit Einfuehrung der Mehrschicht-CT lassen sich umfangreiche Volumendatensaetze schnell und mit hoher Aufloesung erfassen. Die hohe raeumliche Aufloesung reduziert Teilvolumeneffekte und ermoeglicht multiplanare Rekonstruktionen. In Bezug auf das Kolorektum bedeutet dies, dass das Kolon bei ausreichender Darmreinigung und -distension gut beurteilbar ist und transmurale Infiltrationen von kolorektalen Karzinomen sowie Lebermetastasen leichter zu erkennen sind.Bei Kolonkarzinomen hat das T-Staging weniger klinische Relevanz als bei Rektumkarzinomen. Aufgrund des hoeheren Kontrasts ist die MRT der CT im T-Staging von Rektumkarzinomen sowie in der Unterscheidungzwischen Narben- und Rezidivtumorgewebe ueberlegen. (orig.)

  8. Diagnosis of intracranial tumors by CT (computerized tomography) from a practical point of view

    Energy Technology Data Exchange (ETDEWEB)

    Elke, M; Wiggli, U; Huenig, R [Basel Univ. (Switzerland). Inst. fuer Medizinische Radiologie

    1977-04-01

    In a historical abstract the mathematical basis of image reconstruction techniques and CT is reviewed. The enhancement of iodine contrast media is essential in CT diagnostis of space occupying intracranial lesions. Intracranial tumors usually show relatively characteristical but mostly non-specific absorption patterns. Additional clinical information is necessary for differential diagnostic evalution. The development of tables with various tumor patterns is recommended. Absorption feature of primary and secondary brain-tumors with the surrounding edema is explained. Glioblastomas as well as metastases often show a distinct cerebral edema which has been observed in 64% of our patients with metastases and distinctly localized high dense foci in 69%. 6,000 patients were investigated by CT and 1,708 examinations were performed with contrast enhancement. Side-effects are within the known reaction of other intravenously applicated contrast media.

  9. A new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy

    International Nuclear Information System (INIS)

    Arrive, Lionel; Azizi, Louisa; Monnier-Cholley, Laurence; Lewin, Maite; Tubiana, Jean-Michel; Rosmorduc, Olivier; Beaussier, Marc

    2006-01-01

    The purpose of this study was to report a new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy. Forty-three hepatocellular carcinomas were not visible with CT fluoroscopy. A 22-gauge Chiba end-hole needle was inserted in the approximate location of a lesion estimated on the basis of anatomical landmarks demonstrated on both previous MR and CT images. We injected 3 ml of a mixture of nonionic contrast material and saline solution. Following the first injection, contrast solution filled the hepatic lesion in 29 of 43 cases. In 8 of 43 cases, contrast solution was distributed in the normal surrounding liver. In 7 of these 8 cases, repositioning allowed us to adjust the needle in the tumor. In the other 6 of 43 cases, contrast solution spread within capsule or pseudocapsule (pattern 3). In all 6 cases, repositioning allowed to adjust the needle in the tumor. This new technique allows an accurate localization of hepatic tumors that are poorly visible with CT fluoroscopy. (orig.)

  10. Indications for surgical resection of benign pancreatic tumors; Indikationen zur chirurgischen Therapie benigner Pankreastumoren

    Energy Technology Data Exchange (ETDEWEB)

    Isenmann, R.; Henne-Bruns, D. [Chirurgische Universitaetsklinik, Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Ulm (Germany)

    2008-08-15

    Benign pancreatic tumors should undergo surgical resection when they are symptomatic or - in the case of incidental discovery - bear malignant potential. This is the case for the majority of benign pancreatic tumors, especially for intraductal papillary mucinous neoplasms or mucinous cystic adenomas. In addition, resection is indicated for all tumors where preoperative diagnostic fails to provide an exact classification. Several different operative techniques are available. The treatment of choice depends on the localization of the tumor, its size and on whether there is evidence of malignant transformation. Partial duodenopancreatectomy is the oncological treatment of choice for tumors of the pancreatic head whereas for tumors of the pancreatic tail a left-sided pancreatectomy is appropriate. Middle pancreatectomy or duodenum-preserving resection of the pancreatic head is not a radical oncologic procedure. They should only be performed in cases of tumors without malignant potential. (orig.) [German] Die Indikationsstellung zur Resektion benigner Pankreastumoren ist gegeben, wenn es sich um einen symptomatischen Tumor handelt oder - bei einem Zufallsbefund - um einen Tumor mit Potenzial zur malignen Entartung. Dies besteht bei der Mehrzahl der benignen Pankreastumoren, insbesondere bei der intraduktalen papillaeren muzinoesen Neoplasie (IPMN) oder muzinoesen Zystadenomen. Operativer Abklaerung beduerfen auch Tumoren, die unter Ausschoepfung aller diagnostischer Moeglichkeiten nicht eindeutig klassifizierbar sind. An chirurgischen Therapieverfahren stehen verschiedene Techniken zur Verfuegung. Die Wahl des Verfahren haengt von der Groesse und Lokalisation des Tumors ab und von der Frage, ob eine maligne Entartung bereits stattgefunden hat. Das onkologisch korrekte Standardresektionsverfahren bei Tumoren des Pankreaskopfes ist die partielle Duodenopankreatektomie, bei Tumoren des Pankreasschwanzes die Pankreaslinksresektion. Eine segmentale Resektion des

  11. Correlation between the CT manifestations and post-operative survival time in patients with thymic epithelial tumor

    International Nuclear Information System (INIS)

    Chen Juan; Tan Ye; Wang Xiangyang; Du Jun; Pan Jishu; Wei Jiahu

    2011-01-01

    Objective: To describe the CT manifestations of thymic epithelial tumor and explore the correlation between CT findings and post-operative tumor-related survival time. Methods: Ninety-one patients who underwent CT scan before operation were reviewed retrospectively. All cases had operation and were classified according to the WHO classification. The size, contour, shape, density and enhancement of the tumors on CT were assessed. Presence of mediastinal lymphadenopathy, great vessel invasion, metastasis to the lung or plural, myasthenia gravis (MG) were also analyzed. The survival rate was obtained using, the Kaplan-Meier method. The Cox model was applied to determine the factors affecting the tumor-related survivals. Chi square test was used to analyze the relationship between CT findings and WHO classification. Results: Two patients were excluded because of dying of myocardial infarction and colon cancer. The total 5-year survival rate was 84.3% (n=75). Eighty-nine patients had total 91 tumors. Tumors with diameter larger than 5 cm, lobular contour, heterogenous density, and presence of great vessel invasion, mediastinal lymphadenopathy, and metastasis were adverse factors which could significantly affect the survival time. Five-year survival rates of these factors were 72.7%, 77.3%, 76.7%, 73.8%, 30.0%, and 68.8%, respectively. Presence of MG was a favorable factor which also significantly affected the survival time (P 0.05). The result of the Cox multivariate analysis was consistent with that of the Log-rank test. For different WHO classification, there were significant different among the size or contour of the tumors, presence of great vessel invasion, mediastinal lymphadenopathy, and metastasis (χ 2 value were 6.598, 5.737, 18.307, 8.465, and 15.608, respectively P<0.05). Conclusions: CT findings may be served as predictors of clinical prognosis of the thymic epithelial tumors. Adverse factors for survival time are the size of the tumors and presence of

  12. The profound effects of patient arm positioning on organ doses from CT procedures calculated using Monte Carlo simulations and deformable phantoms

    International Nuclear Information System (INIS)

    Liu, Haikuan; Gao, Yiming; Ding, Aiping; Caracappa, Peter F.; George Xu, X.

    2015-01-01

    The purpose of this study was to evaluate the organ dose differences caused by the arms-raised and arms-lowered postures for multidetector computed tomography procedures. Organ doses were calculated using computational phantoms and Monte Carlo simulations. The arm position in two previously developed adult male and female human phantoms was adjusted to represent 'raised' and 'lowered' postures using advanced BREP-based mesh surface geometries. Organ doses from routine computed tomography (CT) scan protocols, including the chest, abdomen-pelvis, and chest-abdomen-pelvis scans, were simulated at various tube voltages and reported in the unit of mGy per 100 mAs. The CT scanner model was based on previously tested work. The differences in organ dose per unit tube current between raised and lowered arm postures were studied. Furthermore, the differences due to the tube current modulation (TCM) for these two different postures and their impact on organ doses were also investigated. For a given scan parameter, a patient having lowered arms received smaller doses to organs located within the chest, abdomen or pelvis when compared with the patient having raised arms. As expected, this is caused by the attenuation of the primary X rays by the arms. However, the skin doses and bone surface doses in the patient having lowered arms were found to be 3.97-32.12 % larger than those in a patient having raised arms due to the fact that more skin and spongiosa were covered in the scan range when the arms are lowered. This study also found that dose differences become smaller with the increase in tube voltage for most of organs or tissues except the skin. For example, the liver dose differences decreased from -15.01 to -11.33 % whereas the skin dose differences increased from 21.53 to 25.24 % with tube voltage increased from 80 to 140 kVp. With TCM applied, the organ doses of all the listed organs in patient having lowered arms are larger due to the additional tube

  13. The stepchild of intestinal diagnostics. Evaluation of radiological methods to diagnose leiomyomas of the small bowel; Das Stiefkind der Darmdiagnostik. Wertigkeit radiologischer Diagnosemoeglichkeiten von Leiomyomen im Duenndarm

    Energy Technology Data Exchange (ETDEWEB)

    Keberle, M.; Wittenberg, G.; Jenett, M.; Hahn, D. [Wuerzburg Univ. (Germany). Inst. fuer Roentgendiagnostik; Mueller, J.G. [Wuerzburg Univ. (Germany). Pathologisches Inst.

    1998-11-01

    Purpose: Various radiological methods to diagnose small bowel neoplasmas and problems of differential diagnosis specially considerating leiomyomas are discussed. Patients and methods: Two patients with leiomyoma of the ileum underwent enteroclysis, computed tomography of the abdomen, intra-arterial DSA and colour Doppler sonography. Another patient with leiomyosarcoma just underwent CT of the abdomen with CT-guided biopsy. Results: Due to the homogenous density and the smooth surface of the tumors in computed tomography and respectively enteroclysis and the presentation of the tumor vascularisation in the angiography and Colour Doppler sonography in both patients a leiomyoma of the small bowel was diagnosed. Postoperatively this diagnosis was histologically confirmed. The CT-findings of the patient with leiomyosarcoma were not suspicious of a malignant tumor. Conclusion: Radiologically it is not possible to determine the dignity of smooth muscle cell tumors safely. That is the reason why the diagnosis has to be achieved operatively. But the histopathological diagnosis based on the mitotic rate may be difficult. Therefore the after care has to be carried out thoroughly. (orig.) [Deutsch] Ziel: Es werden Diagnosemoeglichkeiten von Duenndarmtumoren und differentialdiagnostische Problemstellungen unter besonderer Beruecksichtigung des Leiomyoms diskutiert. Patienten und Methode: Bei zwei Patienten mit einem Leiomyom des Ileums wurde jeweils ein Enteroklysma nach Sellink, eine CT des Abdomens, eine intraarterielle DSA mit selektiver Darstellung der Art.mesenterica superior und eine farbkodierte Duplexsonographie (FKDS) durchgefuehrt. Bei einem Patienten mit Leiomyosarkom wurde lediglich eine CT des Abdomens mit CT-gesteuerter Biopsie durchgefuehrt. Ergebnisse: Aufgrund der homogenen Dichtewerte und der glatten Begrenzung der Tumoren in der CT bzw. dem Enteroklysma, ergaenzt durch die farbdopplersonographische und angiographische Darstellung der Tumorgefaesse, wurde bei

  14. WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

    Energy Technology Data Exchange (ETDEWEB)

    Ouadah, S; Jacobson, M; Stayman, JW; Siewerdsen, JH [Johns Hopkins University, Baltimore, MD (United States); Ehtiati, T [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States)

    2016-06-15

    Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p < 0.001) in the SSIM of the motion-corrected (MC) images compared to uncorrected images. The SSIM in MC-PL images was >0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every

  15. Intraoperative appearance of the resection area in brain-tumor operations in an open 0,5 MRT; Intraoperatives Erscheinungsbild des Resektionsbereichs bei Hirntumoroperationen in einem offenen 0,5-T-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, J. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany). Arbeitsbereich Neuroradiologie; Schneider, J.P.; Schulz, T. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany); Seifert, V.; Trantakis, C. [Universitaetsklinik fuer Neurochirurgie, Leipzig (Germany); Kellermann, S. [Leipzig Univ. (Germany). Abt. fuer Neuropathologie

    1998-11-01

    During MRI-controlled resection of brain tumors using an open MRI system, operation-induced alterations may occur, especially enhancement of the resection cavity wall. This may simulate tumor areas, resulting in false assessment of the resection or resection of non-tumorous areas. Based on 42 MRI- and biopsy-controlled brain tumor resections in an 0.5 T open MRI (Signa SP, GE), the appearance and origin of operation-induced reactions are analyzed. In our opinion, there is a superposition of preformed peritumoral reactions by operation-induced microcontusions. The beginning of the cavity wall enhancement needs at least 10-15 min. MRI-controlled analysis of the intraoperative steps by the neurosurgeon and neuroradiologist allows discrimination of operation-induced reactions from tumor areas and leads to safe operation. (orig.) [Deutsch] Bei der intraoperativen Kontrolle von Hirntumorresektionen in offenen MRT-Geraeten kann es zu operativ induzierten Veraenderungen, insbesondere Rand-enhancement-Zonen, kommen. Diese koennen Tumorreste vortaeuschen, so dass die Radikalitaet des Eingriffs unterschaetzt wird oder nicht tumortragende Hirnareale entfernt werden. Ergebnisse und Diskussion: Anhand von 42 in einem offenen 0,5-T-MRT (Signa SP, GE) vorgenommenen, biopsiekontrollierten Hirntumoroperationen werden Erscheinungsbild und Entstehungsweise der Randveraenderungen analysiert. Bei den haeufig vorzufindenden Rand-enhancement-Zonen handelt es sich um eine Ueberlagerung von praeformierten Tumorrandreaktionen mit Mikrokontusionen. Die Ausbildung dieser Veraenderungen braucht eine Mindestzeit von 10-15 min. Die staendige Analyse der die Tumorresektion begleitenden MRT-Kontrollen durch den Operateur und einen mit der Problematik vertrauten Radiologen gestattet in der Regel die Differenzierung der operativ induzierten Veraenderungen und erhoeht damit die Sicherheit des Eingriffs. (orig.)

  16. Image-guided radiofrequency ablation (RFA) of spinal tumors

    International Nuclear Information System (INIS)

    Gevargez, Athour; Groenemeyer, Dietrich H.W.

    2008-01-01

    Purpose: To evaluate retrospectively the efficacy and safety of radiofrequency ablation (RFA) in patients with spinal tumors. Materials and methods: Forty-one patients (25 men, 16 women; age range, 46-82 years) with nonresectable primary or secondary tumor involvement of the spine unresponsive to chemo- and radiotherapy received RFA treatment. Two radiofrequency ablation systems, one with a cool-tip electrode and one with an expandable electrode catheter, were used. Both systems work impedance controlled with a power output of 150- 200 W. Each coagulation cycle lasted 12-15 min depending on tumor impedance. Several single RFA cycles of 15 min each were used for overlapping RFAs in tumors with diameters of more than 3 cm. Temperature was kept between 50 deg. C and 120 deg. C and was chosen according to spinal cord distance and patient heat tolerance during the ablation. Multi-slice computed tomography (CT) combined with C-arm fluoroscopy guided the intervention. Efficacy outcomes were assessed after about 6 weeks, 6 months, and more than 6 months using standardized questionnaires and indices regarding tumor pain, pain disability, functional activities, quality of life, neurological status, and tumor progression. Results: RFA significantly reduced tumor-induced pain within 6 weeks, improved daily activities, and maintained quality of life. Mean time to tumor progression was 730 ± 54 days (Kaplan-Meier estimate). No RFA-associated complications were reported. Conclusion: RFA of primary and secondary spinal tumors, which were unresponsive to chemo- and radiotherapy and prone to progression, is a safe, resource-saving, and highly effective percutaneous technique in patients with nonresectable spinal tumors

  17. Overcoming the Challenges of BeiDou Receiver Implementation

    Directory of Open Access Journals (Sweden)

    Mohammad Zahidul H. Bhuiyan

    2014-11-01

    Full Text Available Global Navigation Satellite System (GNSS-based positioning is experiencing rapid changes. The existing GPS and the GLONASS systems are being modernized to better serve the current challenging applications under harsh signal conditions. These modernizations include increasing the number of transmission frequencies and changes to the signal components. In addition, the Chinese BeiDou Navigation Satellite system (BDS and the European Galileo are currently under development for global operation. Therefore, in view of these new upcoming systems the research and development of GNSS receivers has been experiencing a new upsurge. In this article, the authors discuss the main functionalities of a GNSS receiver in view of BDS. While describing the main functionalities of a software-defined BeiDou receiver, the authors also highlight the similarities and differences between the signal characteristics of the BeiDou B1 open service signal and the legacy GPS L1 C/A signal, as in general they both exhibit similar characteristics. In addition, the authors implement a novel acquisition technique for long coherent integration in the presence of NH code modulation in BeiDou D1 signal. Furthermore, a simple phase-preserved coherent integration based acquisition scheme is implemented for BeiDou GEO satellite acquisition. Apart from the above BeiDou-specific implementations, a novel Carrier-to-Noise-density ratio estimation technique is also implemented in the software receiver, which does not necessarily require bit synchronization prior to estimation. Finally, the authors present a BeiDou-only position fix with the implemented software-defined BeiDou receiver considering all three satellite constellations from BDS. In addition, a true multi-GNSS position fix with GPS and BDS systems is also presented while comparing their performances for a static stand-alone code phase-based positioning.

  18. Maximum-intensity-projection CT angiography for evaluating head and neck tumors. Usefulness of helical CT and auto bone masking method

    International Nuclear Information System (INIS)

    Sakai, Osamu; Nakashima, Noriko; Ogawa, Chiaki; Shen, Yun; Takata, Yasunori; Azemoto, Shougo.

    1994-01-01

    Angiographic images of 10 adult patients with head and neck tumors were obtained by helical computed tomography (CT) using maximum intensity projection (MIP). In all cases, the vasculature of the head and neck region was directly demonstrated. In the head and neck, bone masking is a more important problem than in other regions. We developed an effective automatic bone masking method (ABM) using 2D/3D connectivity. Helical CT angiography with MIP and ABM provided accurate anatomic depiction, and was considered to be helpful in preoperative evaluation of head and neck tumors. (author)

  19. Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Starkschall, George; Prado, Karl; Dong Lei; Balter, Peter

    2010-01-01

    Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

  20. Prognostic value of PET/CT in lung cancer. Study of survival and tumor metabolic characterization

    International Nuclear Information System (INIS)

    Ladron de Guevara, David; Fuentes Anibal; Farina, Ciro; Corral, Camilo; Pefaur, Raul

    2013-01-01

    PET/CT (Positron emission tomography/computed tomography) is a hybrid image modality widely used in oncology, for staging, therapy evaluation or follow up. Aim: To evaluate the prognostic value of PET/CT in lung cancer. Material and Methods: Retrospective review of PET/CT records, selecting 51 patients with a lung malignancy, mass or nodule referred for PET/CT between December 2008 and December 2010. All had pathological confirmation of malignancy and had not been treated previously. Age, gender, body mass index, radiological features of lung tumor and metastases, and lung tumor 18 F-fluoro-2-deoxy-d-glucose uptake using the SUV (Standardized uptake value) index were recorded. Survival was analyzed using Kaplan-Meier curves and a Cox proportional regression analysis. Results: Pathology confirmed the presence of lung cancer in 47 patients aged 30 to 88 years. Four patients (7.8%) had other type of tumors such as carcinoid or lymphoma. Fifty percent of lung cancer patients died during a mean observation lapse of 18 months (range: 2-34 months). Patients with metastases, local lymph node involvement, a lung tumor size ≥ 3 cm and high tumor uptake (SUVmax > 6) had significantly lower survival. Occurrence of metastases was the only independent prognostic factor in the Cox regression. A lung lesion with a SUVmax ≥ 12 was always associated to hilar/mediastinal lymph node involvement. Conclusions: PET/CT imaging gives important prognostic information in lung cancer patients

  1. Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer

    Directory of Open Access Journals (Sweden)

    Knopp Michael V

    2007-12-01

    Full Text Available Abstract Background 18F-fluorodeoxyglucose (18F-FDG positron emission tomography/computed tomography (PET/CT has become an established method for detecting hypermetabolic sites of known and occult disease and is widely used in oncology surgical planning. Intraoperatively, it is often difficult to localize tumors and verify complete resection of tumors that have been previously detected on diagnostic PET/CT at the time of the original evaluation of the cancer patient. Therefore, we propose an innovative approach for intraoperative tumor localization and verification of complete tumor resection utilizing 18F-FDG for perioperative PET/CT imaging and intraoperative gamma probe detection. Methods Two breast cancer patients were evaluated. 18F-FDG was administered and PET/CT was acquired immediately prior to surgery. Intraoperatively, tumors were localized and resected with the assistance of a handheld gamma probe. Resected tumors were scanned with specimen PET/CT prior to pathologic processing. Shortly after the surgical procedure, patients were re-imaged with PET/CT utilizing the same preoperatively administered 18F-FDG dose. Results One patient had primary carcinoma of breast and a metastatic axillary lymph node. The second patient had a solitary metastatic liver lesion. In both cases, preoperative PET/CT verified these findings and demonstrated no additional suspicious hypermetabolic lesions. Furthermore, intraoperative gamma probe detection, specimen PET/CT, and postoperative PET/CT verified complete resection of the hypermetabolic lesions. Conclusion Immediate preoperative and postoperative PET/CT imaging, utilizing the same 18F-FDG injection dose, is feasible and image quality is acceptable. Such perioperative PET/CT imaging, along with intraoperative gamma probe detection and specimen PET/CT, can be used to verify complete tumor resection. This innovative approach demonstrates promise for assisting the oncologic surgeon in localizing and

  2. Application of C-arm computed tomography in cardiology; Kardiale Anwendung der C-Arm-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Abteilung fuer Kardiologie, Medizinische Poliklinik, Muenchen (Germany); Rohkohl, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Mustererkennung, Department Informatik, Erlangen (Germany); Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Lauritsch, G. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Rittger, H. [Krankenhaus Coburg, Abteilung fuer Kardiologie, Coburg (Germany); Meissner, O. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2009-09-15

    C-arm computed tomography is currently being introduced into cardiac imaging and offers the potential for three-dimensional imaging of the cardiac anatomy within the interventional environment. This detailed view is necessary to support complex interventional strategies, such as transcutaneous valve replacement, interventional therapy of atrial fibrillation, implantation of biventricular pacemakers and assessment of myocardial perfusion. Currently, the major limitation of this technology is its insufficient temporal resolution which limits the visualization of fast moving parts of the heart. (orig.) [German] Durch die Entwicklung der C-Arm-Computertomographie- (CACT-)Angiographie ist es erstmals moeglich, waehrend einer Herzkatheteruntersuchung eine detaillierte dreidimensionale Darstellung der kardialen Anatomie zu erhalten. Derartige zusaetzliche Informationen koennten die Durchfuehrung der immer komplexer werdenden Strategien der interventionellen Kardiologie wirkungsvoll unterstuetzen. Hierzu zaehlen u. a. der transkutane Klappenersatz, die interventionelle Behandlung von Vorhofflimmern, die Implantation biventrikulaerer Schrittmacher sowie die Beurteilung der Myokardperfusion. Die derzeit groesste Limitation dieser Methode ist die relativ geringe zeitliche Aufloesung, die aufgrund der Bewegung des Herzens die Anwendung dieser Technologie einschraenkt. (orig.)

  3. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  4. Role of CT in TNM staging of laryngeal and hypopharyngeal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Querin, F; Galassi, G; Piazza, P; Galofaro, G; Lutman, M; Barzan, L

    1986-01-01

    70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

  5. Correlation of intra-tumor 18F-FDG uptake heterogeneity indices with perfusion CT derived parameters in colorectal cancer.

    Science.gov (United States)

    Tixier, Florent; Groves, Ashley M; Goh, Vicky; Hatt, Mathieu; Ingrand, Pierre; Le Rest, Catherine Cheze; Visvikis, Dimitris

    2014-01-01

    Thirty patients with proven colorectal cancer prospectively underwent integrated 18F-FDG PET/DCE-CT to assess the metabolic-flow phenotype. Both CT blood flow parametric maps and PET images were analyzed. Correlations between PET heterogeneity and perfusion CT were assessed by Spearman's rank correlation analysis. Blood flow visualization provided by DCE-CT images was significantly correlated with 18F-FDG PET metabolically active tumor volume as well as with uptake heterogeneity for patients with stage III/IV tumors (|ρ|:0.66 to 0.78; p-valueheterogeneity of 18F-FDG PET accumulation reflects to some extent tracer distribution and consequently indicates that 18F-FDG PET intra-tumor heterogeneity may be associated with physiological processes such as tumor vascularization.

  6. Multi-phase simultaneous segmentation of tumor in lung 4D-CT data with context information.

    Directory of Open Access Journals (Sweden)

    Zhengwen Shen

    Full Text Available Lung 4D computed tomography (4D-CT plays an important role in high-precision radiotherapy because it characterizes respiratory motion, which is crucial for accurate target definition. However, the manual segmentation of a lung tumor is a heavy workload for doctors because of the large number of lung 4D-CT data slices. Meanwhile, tumor segmentation is still a notoriously challenging problem in computer-aided diagnosis. In this paper, we propose a new method based on an improved graph cut algorithm with context information constraint to find a convenient and robust approach of lung 4D-CT tumor segmentation. We combine all phases of the lung 4D-CT into a global graph, and construct a global energy function accordingly. The sub-graph is first constructed for each phase. A context cost term is enforced to achieve segmentation results in every phase by adding a context constraint between neighboring phases. A global energy function is finally constructed by combining all cost terms. The optimization is achieved by solving a max-flow/min-cut problem, which leads to simultaneous and robust segmentation of the tumor in all the lung 4D-CT phases. The effectiveness of our approach is validated through experiments on 10 different lung 4D-CT cases. The comparison with the graph cut without context constraint, the level set method and the graph cut with star shape prior demonstrates that the proposed method obtains more accurate and robust segmentation results.

  7. Development of an automated extraction method for liver tumors in three dimensional multiphase multislice CT images

    International Nuclear Information System (INIS)

    Nakagawa, Junya; Shimizu, Akinobu; Kobatake, Hidefumi

    2004-01-01

    This paper proposes a tumor detection method using four phase three dimensional (3D) CT images of livers, i.e. non-contrast, early, portal, and late phase images. The method extracts liver regions from the four phase images and enhances tumors in the livers using a 3D adaptive convergence index filter. Then it detects local maximum points and extracts tumor candidates by a region growing method. Subsequently several features of the candidates are measured and each candidate is classified into true tumor or normal tissue based on Mahalanobis distances. Above processes except liver region extraction are applied to four phase images, independently and four resultant images are integrated into one. We applied the proposed method to 3D abdominal CT images of ten patients obtained with multi-detector row CT scanner and confirmed that tumor detection rate was 100% without false positives, which was quite promising results. (author)

  8. Tumor localization and biochemical response to cure in tumor-induced osteomalacia.

    Science.gov (United States)

    Chong, William H; Andreopoulou, Panagiota; Chen, Clara C; Reynolds, James; Guthrie, Lori; Kelly, Marilyn; Gafni, Rachel I; Bhattacharyya, Nisan; Boyce, Alison M; El-Maouche, Diala; Crespo, Diana Ovejero; Sherry, Richard; Chang, Richard; Wodajo, Felasfa M; Kletter, Gad B; Dwyer, Andrew; Collins, Michael T

    2013-06-01

    Tumor-induced osteomalacia (TIO) is a rare disorder of phosphate wasting due to fibroblast growth factor-23 (FGF23)-secreting tumors that are often difficult to locate. We present a systematic approach to tumor localization and postoperative biochemical changes in 31 subjects with TIO. All had failed either initial localization, or relocalization (in case of recurrence or metastases) at outside institutions. Functional imaging with ¹¹¹Indium-octreotide with single photon emission computed tomography (octreo-SPECT or SPECT/CT), and ¹⁸fluorodeoxyglucose positron emission tomography/CT (FDG-PET/CT) were performed, followed by anatomic imaging (CT, MRI). Selective venous sampling (VS) was performed when multiple suspicious lesions were identified or high surgical risk was a concern. Tumors were localized in 20 of 31 subjects (64.5%). Nineteen of 20 subjects underwent octreo-SPECT imaging, and 16 of 20 FDG-PET/CT imaging. Eighteen of 19 (95%) were positive on octreo-SPECT, and 14 of 16 (88%) on FDG-PET/CT. Twelve of 20 subjects underwent VS; 10 of 12 (83%) were positive. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were as follows: sensitivity = 0.95, specificity = 0.64, PPV = 0.82, and NPV = 0.88 for octreo-SPECT; sensitivity = 0.88, specificity = 0.36, PPV = 0.62, and NPV = 0.50 for FDG-PET/CT. Fifteen subjects had their tumor resected at our institution, and were disease-free at last follow-up. Serum phosphorus returned to normal in all subjects within 1 to 5 days. In 10 subjects who were followed for at least 7 days postoperatively, intact FGF23 (iFGF23) decreased to near undetectable within hours and returned to the normal range within 5 days. C-terminal FGF23 (cFGF23) decreased immediately but remained elevated, yielding a markedly elevated cFGF23/iFGF23 ratio. Serum 1,25-dihydroxyvitamin D₃ (1,25D) rose and exceeded the normal range. In this systematic approach to tumor

  9. The registration accuracy analysis of different CT-MRI imaging fusion method in brain tumor

    International Nuclear Information System (INIS)

    Lu Jie; Yin Yong; Shao Qian; Zhang Zicheng; Chen Jinhu; Chen Zhaoqiu

    2010-01-01

    Objective: To find an effective CT-MRI image fusion protocol in brain tumor by analyzing the registration accuracy of different methods. Methods: The simulation CT scan and MRI T 1 WI imaging of 10 brain tumor patients obtained with same position were registered by Tris-Axes landmark ,Tris-Axes landmark + manual adjustment, mutual information and mutual information + manual adjustment method. The clinical tumor volume (CTV) were contoured on both CT and MRI images respectively. The accuracy of image fusion was assessed by the mean distance of five bone markers (d 1-5 ), central position of CTV (d CTV ) the percentage of CTV overlap (P CT-MRI ) between CT and MRI images. The difference between different methods was analyzed by Freedman M non-parameter test. Results: The difference of the means d1-5 between the Tris-Axes landmark,Tris-Axes landmark plus manual adjustment,mutual information and mutual information plus manual adjustment methods were 0.28 cm ±0.12 cm, 0.15 cm ±0.02 cm, 0.25 cm± 0.19 cm, 0.10 cm ± 0.06 cm, (M = 14.41, P = 0.002). the means d CTV were 0.59 cm ± 0.28 cm, 0.60 cm± 0.32 cm, 0.58 cm ± 0.39 cm, 0.42 cm± 0.30 cm (M = 9.72, P = 0.021), the means P CT-MRI were 0.69% ±0.18%, 0.68% ±0.16%, 0.66% ±0.17%, 0.74% ±0.14% (M =14.82, P=0.002), respectively. Conclusions: Mutual information plus manual adjustment registration method was the preferable fusion method for brain tumor patients. (authors)

  10. Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT

    Science.gov (United States)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-03-01

    Purpose: This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. Methods: We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d'. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the fz-axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the (fy, fz) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. Results: For the fz-axis task, the circle + arc orbit was shown to increase d' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d' was increased by a factor of 1.83. Conclusions: This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of

  11. The Added Diagnostic Value of 18F-Fluorodihydroxyphenylalanine PET/CT in the Preoperative Work-Up of Small Bowel Neuroendocrine Tumors.

    Science.gov (United States)

    Addeo, Pietro; Poncet, Gilles; Goichot, Bernard; Leclerc, Loic; Brigand, Cécile; Mutter, Didier; Romain, Benoit; Namer, Izzie-Jacques; Bachellier, Philippe; Imperiale, Alessio

    2018-04-01

    The precise localization of the primary tumor and/or the identification of multiple primary tumors improves the preoperative work-up in patients with small bowel (SB) neuroendocrine tumor (NET). The present study assesses the diagnostic value of 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) positron emission tomography/computed tomography (PET/CT) during the preoperative wok-up of SB NETs. Between January 2010 and June 2017, all consecutive patients with SB NETs undergoing preoperative 18 F-FDOPA PET/CT and successive resection were analyzed. Preoperative work-up included computed tomography (CT), somatostatin receptor scintigraphy (SRS), and 18 F-FDOPA PET/CT. Sensitivity and accuracy ratio for primary and multiple tumor detection were compared with data from surgery and pathology. There were 17 consecutive patients with SB NETs undergoing surgery. Nine patients (53%) had multiple tumors, 15 (88%) metastatic lymph nodes, 3 (18%) peritoneal carcinomatosis, and 9 patients (53%) liver metastases. A total of 70 SB NETs were found by pathology. Surgery identified the primary in 17/17 (100%) patients and recognized seven of 9 patients (78%) with multiple synchronous SB. Preoperatively, 18 F-FDOPA PET/CT displayed a statistically significant higher sensitivity for primary tumor localization (100 vs. 23.5 vs. 29.5%) and multiple tumor detection (78 vs. 22 vs. 11%) over SRS and CT. Compared with pathology, 18 F-FDOPA PET/CT displayed the highest accuracy ratio for number of tumor detected over CT and SRS (2.0 ± 2.2 vs. 0.4 ± 0.7 vs. 0.6 ± 1.5, p = 0.0003). 18 F-FDOPA PET/CT significantly increased the sensitivity and accuracy for primary and multiple SB NET identification. 18 F-FDOPA PET/CT should be included systematically in the preoperative work-up of SB NET.

  12. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  13. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    International Nuclear Information System (INIS)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin

    2012-01-01

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  14. Relationship of preoperative gastric cancer CT enhancement ratio and perfusion parameters with serum tumor marker levels and proliferation molecule expression in tumor lesions

    Directory of Open Access Journals (Sweden)

    Yong-Hong Wang

    2017-06-01

    Full Text Available Objective: To study the relationship of preoperative gastric cancer CT enhancement ratio and perfusion parameters with serum tumor marker levels and proliferation molecule expression in tumor lesions. Methods: A total of 68 patients with gastric cancer treated in the Second Hospital of Yulin City between May 2012 and May 2016 were chosen as observation group and sub-divided into early and middle gastric cancer group (n=41 and advanced gastric cancer group (n=27 according to the tumor stage; 50 patients diagnosed with benign gastric diseases in our hospital during the same period were selected as benign gastric lesion group. CT enhancement rate and perfusion parameters of three groups of patients were detected by CT scan, serum tumor marker levels were evacuated by enzyme-linked immunosorbent assay (ELISA, and the proliferation gene mRNA expression levels were detected by RTPCR method. Results: CER, AF, BV and CL levels of advanced gastric cancer group were higher than those of early and middle gastric cancer group and benign gastric lesion group; serum CA72-4, CA19-9, CA125 and CEA contents of advanced gastric cancer group were higher than those of early and middle gastric cancer group and benign gastric lesion group; CADM1, miRNA-34a and Cystatin M mRNA expression in tissue of advanced gastric cancer group were lower than those of early and middle gastric cancer group and benign gastric lesion group while Survivin and I2PP2A mRNA expression were higher than those of early and middle gastric cancer group and benign gastric lesion group. The Pearson test showed that the CT enhancement rate and perfusion parameters in patients with gastric cancer are directly correlated with the serum tumor marker levels and the proliferation gene expression in tumor lesions. Conclusion: Preoperative gastric cancer CT enhancement rate and perfusion parameters are directly related to the tumor malignancy, and can be used as a reliable method for the long-term tumor

  15. Tracker-on-C for cone-beam CT-guided surgery: evaluation of geometric accuracy and clinical applications

    Science.gov (United States)

    Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.

    2012-02-01

    Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm

  16. Brain tumors in children and teenagers up to 18 in CT

    International Nuclear Information System (INIS)

    Kabula, S.; Trzcinska, I.; Lasek, W.; Goszczynski, W.; Nawrot, M.; Boron, Z.

    1995-01-01

    The results of the CT investigation in children and teenagers up to 18, made in 1990-1994 were exposed to retrospective analysis: 2279 children were examined. The computer research proved the pathological changes in case 1205 people - 52%. In this group 58 children turned out to suffer from brain tumors. The most frequent tumor spatted was: astrocytoma (8), ependymoma (5), oligodendroglioma (3). The brain tumors happen to appear more often in case of boys (34) than in case of girls (22). (author)

  17. FDG–PET–CT reduces the interobserver variability in rectal tumor delineation

    International Nuclear Information System (INIS)

    Buijsen, Jeroen; Bogaard, Jørgen van den; Weide, Hiska van der; Engelsman, Stephanie; Stiphout, Ruud van; Janssen, Marco; Beets, Geerard; Beets-Tan, Regina; Lambin, Philippe; Lammering, Guido

    2012-01-01

    Background and purpose: Previously, we showed a good correlation between pathology and an automatically generated PET-contour in rectal cancer. This study analyzed the effect of the use of PET–CT scan on the interobserver variation in GTV definition in rectal cancer and the influence of PET–CT on treatment volumes. Materials and methods: Forty two patients diagnosed with rectal cancer underwent an FDG–PET–CT for radiotherapy planning. An automatic contour was created on PET-scan using the source-to-background ratio. The GTV was delineated by 5 observers in 3 rounds: using CT and MRI, using CT, MRI and PET and using CT, MRI and PET auto-contour. GTV volumes were compared and concordance indices (CI) were calculated. Since the GTV is only a small portion of the treatment volume in rectal cancer, a separate analysis was performed to evaluate the influence of PET on the definition of the CTV used in daily clinical practice and the caudal extension of the treatment volumes. Results: GTV volumes based on PET were significantly smaller. CIs increased significantly using PET and the best interobserver agreement was observed using PET auto-contours. Furthermore, we found that in up to 29% of patients the CTV based on PET extended outside the CTV used in clinical practice. The caudal border of the treatment volume can be tailored using PET-scan in low seated tumors. Influence of PET on the position of the caudal border was most pronounced in high seated tumors. Conclusion: PET–CT increases the interobserver agreement in the GTV definition in rectal cancer, helps to avoid geographical misses and allows tailoring the caudal border of the treatment volume.

  18. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    International Nuclear Information System (INIS)

    Jensen, Nikolaj K. G.; Stewart, Errol; Lock, Michael; Fisher, Barbara; Kozak, Roman; Chen, Jeff; Lee, Ting-Yim; Wong, Eugene

    2014-01-01

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT

  19. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Nikolaj K. G., E-mail: nkyj@regionsjaelland.dk [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Stewart, Errol [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Lock, Michael; Fisher, Barbara [Radiation Oncology, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Kozak, Roman [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Chen, Jeff [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Lee, Ting-Yim [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Wong, Eugene [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Department of Physics and Astronomy, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-05-15

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

  20. Importance of Preoperative Rectal Ultrasound and CT in Rectal Tumors

    International Nuclear Information System (INIS)

    Schnellyova, T.

    2011-01-01

    Introduction: The reason of high mortality of colorectal carcinoma is above all the fact, that majority of diseases are detected in progressive stage. Radical change in this unfavorable mortality rate can be achieved only by targeted search for early stages of the disease. Early diagnostics consists in rectoscopy and colonoscopy. Regarding X-ray methods it is X-ray irigography. Regarding CT examinations it is CT irigography, virtual colonoscopy. Another examination can be USG examination of abdomen and endo sonographic examination of rectum. Materials and methods: In the period from June 2006 to December 2010, in 60 patients out of the total number 106 examined patients, tumorous affection of rectum CT examination of pelvis and abdomen separately or pelvisand abdomen at one session was made in 3186 patients. In 115 patients we discovered malign tumorous illness of colon. Metastatic affection in the form of distant metastases was proven n 63 patients. 403 patients had CT irigography examination. In 77 out of them we diagnosed colon carcinoma. CT colonoscopy did not discover in our group of 30 patients examined the presence of colon carcinoma. Results: In the group of 60 patients who were diagnosed rectal carcinoma, in 29 patients expansive infiltrative affection was evaluated in endorectal sonography, histologically confirmed in 28 patients - 96,5 %, expansive affection in 41 patients with histological verification in 100 %. With CT we diagnosed 52 expansive tumorous processes, histologically confirmed in 47 patients - 90,38 %. In 63 patients expansive infiltrative process was evaluated, histologically confirmed in 52 patients 82,53 %. In total of 115 examinations there was conformance with histological examination in 99 patients - 86,08 %. In CT irigography we diagnosed colon tumour in 77 patients. Expansive growth was evaluated in 40 patients, histologically confirmed in 37 patients - 92,5 %. Expansive infiltrative expansion was evaluated in 37 patients, with

  1. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  2. 18F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    International Nuclear Information System (INIS)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober; Middendorp, Markus; Mack, Martin; Vogl, Thomas J.; Bisdas, Sotirios

    2009-01-01

    The purpose of this paper is to evaluate the impact of adding combined 18 F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P≥0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6±18.6 ml, the mean volume derived by the MR imaging was 17.6±19.1 ml while the estimated by PET/CT volume was 18.8±18.1 ml (P≤0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  3. A semiautomatic CT-based ensemble segmentation of lung tumors: comparison with oncologists' delineations and with the surgical specimen.

    Science.gov (United States)

    Rios Velazquez, Emmanuel; Aerts, Hugo J W L; Gu, Yuhua; Goldgof, Dmitry B; De Ruysscher, Dirk; Dekker, Andre; Korn, René; Gillies, Robert J; Lambin, Philippe

    2012-11-01

    To assess the clinical relevance of a semiautomatic CT-based ensemble segmentation method, by comparing it to pathology and to CT/PET manual delineations by five independent radiation oncologists in non-small cell lung cancer (NSCLC). For 20 NSCLC patients (stages Ib-IIIb) the primary tumor was delineated manually on CT/PET scans by five independent radiation oncologists and segmented using a CT based semi-automatic tool. Tumor volume and overlap fractions between manual and semiautomatic-segmented volumes were compared. All measurements were correlated with the maximal diameter on macroscopic examination of the surgical specimen. Imaging data are available on www.cancerdata.org. High overlap fractions were observed between the semi-automatically segmented volumes and the intersection (92.5±9.0, mean±SD) and union (94.2±6.8) of the manual delineations. No statistically significant differences in tumor volume were observed between the semiautomatic segmentation (71.4±83.2 cm(3), mean±SD) and manual delineations (81.9±94.1 cm(3); p=0.57). The maximal tumor diameter of the semiautomatic-segmented tumor correlated strongly with the macroscopic diameter of the primary tumor (r=0.96). Semiautomatic segmentation of the primary tumor on CT demonstrated high agreement with CT/PET manual delineations and strongly correlated with the macroscopic diameter considered as the "gold standard". This method may be used routinely in clinical practice and could be employed as a starting point for treatment planning, target definition in multi-center clinical trials or for high throughput data mining research. This method is particularly suitable for peripherally located tumors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  5. Comparative evaluation of 11C-MET PET-CT and MRI for GTV delineation in precision radiotherapy for gliomas

    International Nuclear Information System (INIS)

    Wang Ru; Qian Liting; Wang Shicun; Liu Wei; Luo Wenguang; Zhang Hongbo; Li Guanghu; Hu Zhigang; Liu Lei

    2014-01-01

    Objective: To evaluate the difference between MRI and 11 C-MET PET-CT for gross tumor volume (GTV) delineation in the precision radiotherapy for gliomas. Methods: Six patients with a pathologically confirmed diagnosis of gliomas were selected for target delineation. Five physicians in our department were called to delineate the GTV based on the preoperative MRI and 11 C-MET PET-CT images of these patients. The GTVs based on the two methods were compared. Results: There was no significant difference between the GTVs based on MRI and 11 C-MET PET-CT (P=0.917), and their coefficients of variation were also similar (P=0.600). The coincidences of GTVs were different among the patients, with a maximum value of 73.0% and a minimum value of 51.8%. GTV showed no significant difference when defined by different physicians on MRI and PET-CT (P=0.709); the biggest difference was 27.66 cm 3 on PET-CT and 40.37 cm 3 on MRI. Conclusions: The boundaries of gliomas defined on MRI and PET-CT are different. The GTVs delineated by different physicians on MRI and PET-CT are similar, and the biggest difference on PET-CT is smaller than that on MRI, which suggests that 11 C-MET PET-CT is a more direct way for displaying GTV. (authors)

  6. CT-guided percutaneous neurolysis methods. State of the art and first results; CT-gesteuerte Neurolysen. Stand der Technik und aktuelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Richter, G.M. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Roeren, T. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-09-01

    konnten sich im letzten Jahrzehnt als CT-gesteuerte Neurolyseverfahren aufgrund hoher Zielgenauigkeit in der klinischen Routine etablieren. Irreversible Komplikationen werden bei Einhalten der korrekten Technik und Verwendung duenner 21- oder 22-gg.-Nadeln nur sporadisch beschrieben. Wir beobachten bei 20 durchgefuehrten lumbalen Sympathikolysen 7 klinische Verbesserungen und 13 Amputationen. Die Literaturergebnisse der Methode schwanken demgegenueber bei der lumbalen Sympathikolyse von 39-89% klinischer Erfolgsrate, bei der thorakalen Sympathikolyse von 70-100% und bei der Zoeeliakusblockade von 0-100%. Die Hypothese, eine Extremitaetenerwaermung nach Sympathikolyse sei nur durch Stealeffekte zugunsten der Hautdurchblutung bedingt, konnte durch Flussmessungen widerlegt werden. Waehrend bei der lumbalen Sympathikolyse vor allem die Vorselektion des Patientenguts die unterschiedlichen Erfolgsraten erklaert, spielen bei den anderen Verfahren vor allem die Indikationsstellungen eine herausragende Rolle. Patienten mit palmarer Hyperhidrose profitieren mehr von der perkutanen Neurolyse als Patienten mit Raynaudsymptomatik, Patienten mit Pankreaskarzinom mehr als solche mit Pankreatitis. (orig./VHE)

  7. Pilzinfektionen des Zentralnervensystems bei immunkompetentem Wirt

    NARCIS (Netherlands)

    Tintelnot, K.; de Hoog, G.S.; Haase, G.

    2014-01-01

    Die Mehrzahl von Pilzinfektionen, die zu mykotischen Tumoren führen und bei Patienten ohne jegliche prädisponierende Vorerkrankung auftreten, wird durch Cryptococcus gattii bzw. C. neoformans oder durch Schwärzepilze, insbesondere durch Cladophialophora bantiana, Ramichloridium mackenziei, Exophiala

  8. Imaging diagnostics of the wrist: MRI and Arthrography/Arthro-CT; Bildgebende Diagnostik des Handgelenkes: MRT und Arthrographie/Arthro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Klein, H.M.; Balas, R.; Neugebauer, F. [Radiologische Gemeinschaftspraxis, Betzdorf (Germany); Vrsalovic, V. [Handchirugie, Marienhospital Siegen, Siegen (Germany)

    2002-02-01

    Purpose: To evaluate the use of magnetic resonance imaging (MRI) compared with arthrography and arthro-CT (AG/ACT) in patients with wrist pain. Methods: MRI and arthrography/arthro-CT (AG/ACT) of the wrist joint were retrospectively evaluated in 346 patients over a three-year period. Imaging findings were correlated to surgical results (n=78) or clinical course in an at least 6-month follow-up. Results: For tears of the triangular fibrocartilage, arthrography, arthro-CT, and MRI demonstrated a sensitivity and specificity of more than 0.96. Only the positive predictive value was superior for arthrography/arthro-CT (0.99 and 0.98, respectively) compared with MRI (0.94). Arthrography was superior for functional diagnosis of scapho-lunate ligament tears (n=25). Ulno-lunate and ulno-triquetral ligament defects were demonstrated more exactly by arthrography. Traumatic osseous defects, particularly scaphoid fractures (n=33) and avascular necrosis (n=17), were better diagnosed using MRI. Conclusion: For suspected lesions of the triangular fibrocartilage complex, AG/ACT is slightly more reliable than MRI. However, MRI was found to be highly accurate in diagnosing TFC tears, and is superior to AG/ACT in detecting traumatic and vascular lesions of the wrist. (orig.) [German] Ziel: Die Untersuchung der diagnostischen Aussagekraft von Magnetresonanz-Tomographie (MRT), Arthrographie (AG) und Arthro-CT (ACT) bei Erkrankungen des Handgelenkes. Methodik: Insgesamt 346 Untersuchungen des Handgelenkes wurden fuer einen dreijaehrigen Beobachtungszeitraum retrospektiv ausgewertet. Es wurden 211 MRT, 151 Arthrographien (AG) und 126 Arthro-CT (ACT) durchgefuehrt. Alle Diagnosen wurden operativ (n=78) oder durch den klinischen Verlauf in einer 6-monatigen Nachbeobachtung gesichert. Ergebnisse: Fuer die Diagnostik von Laesionen des diskoulnaren Komplexes lag die Sensitivitaet und Spezifitaet von AG, ACT und MRT ueber 0,96. Lediglich der positive Vorhersagewert differierte, allerdings nicht

  9. Giant cell tumor of the rib: Two cases of F-18 FDG PET/CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Lim; Yoo, Le Ryung; Lee, Yeong Joo; Jung, Chan Kwon [Seoul St. Mary' s Hospital, College of MedicineThe Catholic University of Korea, Seoul (Korea, Republic of); Park, Sonya Young Ju [Molecular Imaging Program, Dept. of Radiology, Stanford Hospital and Clinics, Stanford (Korea, Republic of)

    2017-06-15

    We report two cases of giant cell tumor arising from the rib and their F-18 FDG PET/CT findings. The two patients complained of chest wall pain, and large lobulated soft tissue masses with intense FDG uptake were seen on F-18 FDG PET/CT. A malignant tumor such as osteosarcoma or chondrosarcoma was suspected due to the large size of the mass, bony destruction, and intense FDG uptake. En bloc resection was performed and final pathologic results revealed giant cell tumor of the rib. Giant cell tumor of the rib is very rare, and larger lesions with high FDG uptake can be misdiagnosed as an intrathoracic malignancy arising from the rib, pleura, or chest wall.

  10. CT features of the subtypes of thymic epithelial tumors on the basis of the world health organization classification

    International Nuclear Information System (INIS)

    Guo Xiaoyu; Yu Hong; Xiao Xiangsheng

    2013-01-01

    Thymic epithelial tumors including thymomas and thymic carcinomas have well-known heterogeneous oncologic behaviors and variable histologic features. They show variable and unpredictable evolutions ranging from an indolent non-invasive feature to a highly infiltrative and metastasising one. Currently, CT is a common and efficient imaging method for assessing thymic epithelial tumors. CT evaluation is the main reference for preoperative clinic staging and histological classification. CT features of subtypes of thymic epithelial tumors on the basis of the World Health Organization classification provide the foundation for the diagnosis and predicting prognosis. (authors)

  11. Artifact reduction of different metallic implants in flat detector C-arm CT.

    Science.gov (United States)

    Hung, S-C; Wu, C-C; Lin, C-J; Guo, W-Y; Luo, C-B; Chang, F-C; Chang, C-Y

    2014-07-01

    Flat detector CT has been increasingly used as a follow-up examination after endovascular intervention. Metal artifact reduction has been successfully demonstrated in coil mass cases, but only in a small series. We attempted to objectively and subjectively evaluate the feasibility of metal artifact reduction with various metallic objects and coil lengths. We retrospectively reprocessed the flat detector CT data of 28 patients (15 men, 13 women; mean age, 55.6 years) after they underwent endovascular treatment (20 coiling ± stent placement, 6 liquid embolizers) or shunt drainage (n = 2) between January 2009 and November 2011 by using a metal artifact reduction correction algorithm. We measured CT value ranges and noise by using region-of-interest methods, and 2 experienced neuroradiologists rated the degrees of improved imaging quality and artifact reduction by comparing uncorrected and corrected images. After we applied the metal artifact reduction algorithm, the CT value ranges and the noise were substantially reduced (1815.3 ± 793.7 versus 231.7 ± 95.9 and 319.9 ± 136.6 versus 45.9 ± 14.0; both P metallic objects and various sizes of coil masses. The rater study achieved an overall improvement of imaging quality and artifact reduction (85.7% and 78.6% of cases by 2 raters, respectively), with the greatest improvement in the coiling group, moderate improvement in the liquid embolizers, and the smallest improvement in ventricular shunting (overall agreement, 0.857). The metal artifact reduction algorithm substantially reduced artifacts and improved the objective image quality in every studied case. It also allowed improved diagnostic confidence in most cases. © 2014 by American Journal of Neuroradiology.

  12. A case of falx meningiomas showing an unusual extension on CT

    International Nuclear Information System (INIS)

    Tsuha, Mitsuru; Fudaba, Hiroyoshi; Orita, Tetsuji; Wakuta, Yukio; Aoki, Hideo

    1986-01-01

    It is well known that homogeneous high-density areas with well-defined borders and marked contrast enhancements on CT scans are characteristic features of meningiomas. However, there are a few cases of meningiomas which are more difficult to diagnose because of their unusual CT findings. We have, for example, recently experienced a case of falx meningioma with a small attachment to the flax and a large exophytic component in the brain parenchyma. This 53-year-old female had complained of dull headaches for several years. She had then suffered speech disturbance in June, 1983, followed by a weakness of her right arm. She was referred to our clinic on Oct. 31, 1983. The neurological findings on admission were dyscalculia, mild motor dysphasia, and right hemiparesis to a minor degree. CT revealed a left frontal iso- and high-density mass lesion and also central, partly visible, low-density areas. A postinfusion study showed a moderate contrast enhancement. Also noted were a partial attachment of these tumors to the falx and a more prominent contrast enhancement of these areas than those of other tumor sites. A left internal carotid angiogram revealed a frontal tumor stain, fed by the left ACA and MCAs; early venous drainage was also seen. Moreover, left external carotid angiography showed a small tumor stain adjacent to the falx. Left frontoparietal craniotomy, on Nov. 14, 1983, revealed a soft, well-defined tumor, partly attached to the tumor. Histology indicated a meningioma with partial anisocytosis and mitoses of tumor cells; this was consequently diagnosed as a malignant meningioma. Intracranial meningiomas with a small attachment to the falx and large areas of exophytic components are rare CT findings. In addition to the CT findings mentioned above, the heterogeneity of the absorption coefficients of meningiomas on CT and differential diagnosis were discussed. (author)

  13. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  14. Hyperonenproduktion in C+C- und Si+Si-Kollisionen bei 158 GeV pro Nukleon

    CERN Document Server

    Kraus, Ingrid

    2004-01-01

    Ultrarelativistische Schwerionenstöße werden seit etwa 15 Jahren untersucht, um Kernmaterie unter extremen Bedingungen zu erforschen; in Kollisionen schwerer Atomkerne kann bei hohen Einschußenergien Kernmaterie stark komprimiert und aufgeheizt werden. Die Bedeutung dieser Experimente wird durch Berechnungen der Quanten-Chromo-Dynamik auf raumzeitlichen Gittern hervorgehoben, die bei ausreichend hoher Energiedichte eine Phase voraussagen, in der die Quarks nicht mehr in Hadronen gebunden sind, sondern zusammen mit den Gluonen ein partonisches System ausbilden. Ist das System hinreichend groß und equilibriert, wird es als Quark-Gluon-Plasma bezeichnet. Die als Signatur für das Überschreiten der Phasengrenze vorgeschlagene erhöhte Produktion Seltsamkeit tragender Teilchen wurde in der Gegenüberstellung von elementaren Proton+Proton-Interaktionen und Kern+Kern-Stößen experimentell über einen weiten Energiebereich bestätigt. Eine solche Überhöhung kann aber auch durch rein hadronische Phänomene her...

  15. CT evaluation of patient deep inspiration self-breath-holding: How precisely can patients reproduce the tumor position in the absence of respiratory monitoring devices?

    International Nuclear Information System (INIS)

    Onishi, Hiroshi; Kuriyama, Kengo; Komiyama, Takafumi; Tanaka, Shiho; Ueki, Junko; Sano, Naoki; Araki, Tsutomu; Ikenaga, Satoshi; Tateda, Yoshihito; Aikawa, Yoshihito

    2003-01-01

    The aim of the present study was to evaluate the reproducibility of tumor position under patient deep inspiration self-breath-holding in the absence of respiratory monitoring devices, as well as to compare the reproducibility of deep inspiration self-breath-holding on the verbal command of a radiation technologist (Passive mode) with that initiated by patients' own estimation (Active mode). Twenty patients with lung cancer were shown how the tumor and diaphragm move during the respiration cycle. Patients were instructed to hold their breath during deep inspiration and reproduce identical tumor position as well as possible either by the Active mode or by the Passive mode. After patients had practiced self-breath-holding during deep inspiration, a set of three CT scans was obtained for each of the two modes of self-breath-holding (6 CT scans total) to obtain randomly timed images of 2 mm thickness in the vicinity of the tumor. The first three scans were performed during breath-hold using the Active mode, and next three scans were using the Passive mode. Maximum difference in tumor position for the three CT scans was then calculated along three axes: cranial-caudal (C-C); anterior-posterior (A-P); and right-left (R-L). In the 20 patients who underwent analysis of self-breath-holding, mean maximum difference in tumor position obtained under breath-hold using the Active and the Passive modes were: 2.2 and 3.1 mm along the C-C axis; 1.4 and 2.4 mm along the A-P axis; and 1.3 and 2.2 mm along the R-L axis, respectively. These differences in all axes were significantly smaller (p<0.05) for the Active mode than for the Passive mode. Most tumors displayed maximal respiratory movement along the C-C axis, and minimal movement along the R-L axis, but tumors located in the upper lung displayed maximal movement along the A-P axis. Significant correlation (p<0.05) was observed between differences along three axes in either mode of breath-hold. In conclusion, the reproducibility of

  16. Pulmonary Metastasis from Rectal Cancer on Chest CT Is Correlated with 3T MRI Primary Tumor Location

    International Nuclear Information System (INIS)

    Han, Na Yeon; Kim, Min Ju; Park, Beon Jin; Sung, Deuk Jae; Chung, Kyoo Byung; Oh, Yu Whan

    2011-01-01

    To evaluate the association between the incidence of pulmonary metastasis on chest CT and the location of the primary tumor on rectal MRI. One hundred and nine consecutive patients with rectal adenocarcinoma underwent chest CT and 3T rectal MRI. Two radiologists classified the tumor on MRI as an upper (> 10 cm from the anal verge), mid (5-10 cm), or lower rectal tumor (< 5 cm) by consensus. All chest CT scans were retrospectively reviewed for the presence of metastasis. We used Fisher's exact test to evaluate the correlation between the incidence of pulmonary metastasis with the location of the rectal cancer and the Mantel-Haenszel test to control for local tumor stage. We only included the 60 patients with upper (n = 26) or lower (n = 34) rectal cancer, because of the complicated venous drainage system of the mid rectum. Among these, 9 (15%) showed evidence of pulmonary metastasis on chest CT and almost all (89%, 8/9) patients had lower rectal cancer. The incidence of pulmonary metastasis between the two groups was statistically different (p < 0.05) when local tumor stage was controlled. The incidence of pulmonary metastasis was significantly higher for lower than upper rectal cancers when the T-stage of the tumor was accounted for.

  17. {sup 18}F-fluorodeoxyglucose-PET/CT to evaluate tumor, nodal disease, and gross tumor volume of oropharyngeal and oral cavity cancer: comparison with MR imaging and validation with surgical specimen

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Oliver; Chambron-Pinho, Nicole; Sader, Rober [JW Goethe University, Department of Oromaxillofacial Surgery, Frankfurt (Germany); Middendorp, Markus [JW Goethe University, Department of Nuclear Medicine, Frankfurt (Germany); Mack, Martin; Vogl, Thomas J. [JW Goethe University, Department of Radiology, Frankfurt (Germany); Bisdas, Sotirios [Eberhard Karls University, Department of Neuroradiology, Tuebingen (Germany)

    2009-10-15

    The purpose of this paper is to evaluate the impact of adding combined {sup 18}F-PET/CT to MRI for T and N staging of the oral and oropharyngeal cancer and calculation of the gross tumor volume (GTV) having histopathology as reference standard. PET/CT and MRI were performed in 66 patients with suspected oral and oropharyngeal cancer (41 primary tumors/25 recurrent tumors) and nodal disease (114 nodes). Statistical analysis included the McNemar test, sensitivity, specificity for the diagnostic modalities as well as regression analysis, and Bland-Altman graphs for calculated tumor volumes. There was no statistically significant difference between the two modalities compared to pathological findings regarding detection of disease (P{>=}0.72). The sensitivity/specificity for tumor detection were 100/80% and 96.72/60% for MRI and PET/CT, respectively. The sensitivity/specificity for nodal metastases were 88.46/75% and 83.81/73.91% for MRI and PET/CT, respectively. In 18% of cases, the MRI-based T staging resulted in an overestimation of the pathologic tumor stage. The corresponding rate for PET/CT was 22%. Regarding the treated necks, both modalities showed 100% sensitivity for detection of the recurrent lesions. In necks with histologically N0 staging, MRI and PET/CT gave 22% and 26% false positive findings, respectively. The mean tumor volume in the pathologic specimen was 16.6{+-}18.6 ml, the mean volume derived by the MR imaging was 17.6{+-}19.1 ml while the estimated by PET/CT volume was 18.8{+-}18.1 ml (P{<=}0.007 between the three methods). The Bland-Altman analysis showed a better agreement between PET/CT and MRI. The diagnostic performance of FDG-PET/CT in the local staging of oral cancer is not superior to MRI. (orig.)

  18. The diagnosis of intracranial tumors by CT (computerized tomography) from a practical point of view

    International Nuclear Information System (INIS)

    Elke, M.; Wiggli, U.; Huenig, R.

    1977-01-01

    In a historical abstract the mathematical basis of image reconstruction techniques and CT is reviewed. The enhancement of iodine contrast media is essential in CT diagnostis of space occupying intracranial lesions. Intracranial tumors usually show relatively characteristical but mostly non-specific absorption patterns. Additional clinical information is necessary for differential diagnostic evalution. The development of tables with various tumor patterns is recommended. Absorption feature of primary and secondary brain-tumors with the surrounding edema is explained. Glioblastomas as well as metastases often show a distinct cerebral edema which has been observed in 64% of our patients with metastases and distinctly localized high dense foci in 69%. 6,000 patients were investigated by CT and 1,708 examinations were performed with contrast enhancement. Side-effects are within the known reaction of other intravenously applicated contrast media. (orig.) [de

  19. Repeated cycles of 5-fluorouracil chemotherapy impaired anti-tumor functions of cytotoxic T cells in a CT26 tumor-bearing mouse model.

    Science.gov (United States)

    Wu, Yanhong; Deng, Zhenling; Wang, Huiru; Ma, Wenbo; Zhou, Chunxia; Zhang, Shuren

    2016-09-20

    Recently, the immunostimulatory roles of chemotherapeutics have been increasingly revealed, although bone marrow suppression is still a common toxicity of chemotherapy. While the numbers and ratios of different immune subpopulations are analyzed after chemotherapy, changes to immune status after each cycle of treatment are less studied and remain unclear. To determine the tumor-specific immune status and functions after different cycles of chemotherapy, we treated CT26 tumor-bearing mice with one to four cycles of 5-fluorouracil (5-FU). Overall survival was not improved when more than one cycle of 5-FU was administered. Here we present data concerning the immune statuses after one and three cycles of chemotherapy. We analyzed the amount of spleen cells from mice treated with one and three cycles of 5-FU as well as assayed their proliferation and cytotoxicity against the CT26 tumor cell line. We found that the absolute numbers of CD8 T-cells and NK cells were not influenced significantly after either one or three cycles of chemotherapy. However, after three cycles of 5-FU, proliferated CD8 T-cells were decreased, and CT26-specific cytotoxicity and IFN-γ secretion of spleen cells were impaired in vitro. After one cycle of 5-FU, there was a greater percentage of tumor infiltrating CD8 T-cells. In addition, more proliferated CD8 T-cells, enhanced tumor-specific cytotoxicity as well as IFN-γ secretion of spleen cells against CT26 in vitro were observed. Given the increased expression of immunosuppressive factors, such as PD-L1 and TGF-β, we assessed the effect of early introduction of immunotherapy in combination with chemotherapy. We found that mice treated with cytokine induced killer cells and PD-L1 monoclonal antibodies after one cycle of 5-FU had a better anti-tumor performance than those treated with chemotherapy or immunotherapy alone. These data suggest that a single cycle of 5-FU treatment promoted an anti-tumor immune response, whereas repeated chemotherapy

  20. Brain tumors and CT scan in infants and children, (1). The impact on pediatric neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Ohi, S; Velasco, J M [Northwestern Univ., Chicago, IL (USA). Medical School

    1980-10-01

    The dramatic change in the neuroradiological procedures have been noted after CT scan was introduced in the last several years. Remarkable decreasing numbers of angiographic, pneumoencephalographic and other invasive neuroradiologic studies as well as nuclear brain scan were also found in the pediatric neuroradiology. The authors analyzed the total numbers of these studies performed in the last several years in pediatric neurological/neurosurgical practice in the light of the impact of CT scan especially in the diagnostic procedures and treatments of brain tumor in children. Although the number of these procedures decreased up to 49% in plain skull X-ray, 54% in cerebral angiography, 70% in pneumoencephalography/ventriculography and 79% in nuclear brain scan after CT scan was installed in our results, it is extremely important to renew understanding of those characteristics in each special procedures. Cerebral angiography as well as pneumoencephalography may give the surgeon more precise ideas of the anatomical relationship between the lesion and other normal structures, especially in the posterior fossa tumor in which CT scan occassionally demonstrates only a gross finding. A case with false negative result and another case with a complicated anatomical structure in CT scan were presented. The significance of cerebral angiography and other invasive studies in the diagnosis and follow up of brain tumor in CT scan were discussed.

  1. Locoregional recurrence of rectal carcinoma. A CT-analysis and a target volume concept in adjuvant radiotherapy; Das lokoregionaere Rezidiv des Rektumkarzinoms. Eine computertomographische Analyse und ein Zielvolumenkonzept fuer die adjuvante Radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Bagatzounis, A. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Koelbl, O. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Mueller, G. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Oppitz, U. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Willner, J. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Flentje, M. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie

    1997-02-01

    wurden anhand der Kontrastmittel-CT ermittelt. Die Lymphknotenrezidive wurden unterteilt in: pararektale, praesakrale, Iliaca-interna-, Iliaca-externa, Iliaca-communis- und paraaortale Rezidive. Ergebnisse: Bei 61% der Patienten nach Rektumexstirpation und bei 66% nach anteriorer Resektion wurde ein kombiniertes Tumorbett-/Lymphknotenrezidiv festgestellt. Isolierte Lymphknotenrezidive waren selten (4% bzw. 5%). Sowohl nach Rektumexstirpation als auch nach anteriorer Resektion und Hartmann-Operation waren die Tumorbettrezidive am haeufigsten im Praesakralraum lokalisiert. Unabhaengig von der Operationsmethode und dem Primaertumorsitz fand sich meist eine Infiltration des Praesakralraums in Hoehe S4 bis zum Steissbein (Inzidenz 65% bis 86%). Nach anteriorer Resektion war die Anastomose in 93% der Faelle ins Rezidivgeschehen involviert. Die Beckenbodenetage kaudal der Steissbeinspitze war bei 9 der 96 Patienten nach Rektumexstirpation der Ausgangsort des Rezidivs. Alle 9 Patienten hatten initial einen tiefsitzenden Tumor (unterhalb 6 cm). Ein isoliertes perineales Rezidiv wurde bei nur 2 Patienten nach Rektumexstirpation festgestellt. Bei tiefsitzenden Tumoren und nach Rektumexstirpation war die Vagina in 2 Drittel der Faelle infiltriert. Die Inzidenz der Iliaca-interna-, pararektalen und praesakralen Lymphknotenrezidive war 47 bis 59%. Die Inzidenz der Iliaca-externa-Lymphknotenrezidive betrug 7% nach Rektumexstirpation und 2% nach anteriorer Resektion/Hartmann-Operation. (orig./AJ)

  2. Differentiation between tuberculosis and primary tumors in the adrenal gland: evaluation with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Yang, Zhi-Gang; Guo, Ying-Kun; Li, Yuan; Min, Peng-Qiu; Yu, Jian-Qun; Ma, En-Sen

    2006-01-01

    The aim of the present study is to determine imaging criteria for differentiating tuberculosis from primary tumors in the adrenal gland on contrast-enhanced CT. Non-contrast and contrast-enhanced CT features in 108 patients with adrenal tuberculosis (n=34) and primary tumor (n=74) were retrospectively assessed for the location, size, calcification and enhancement patterns. The primary tumors included 41 adenomas, 11 pheochromocytomas, 4 carcinomas, 3 lymphomas, 6 myelolipomas, 6 ganglioneuromas, 2 neurilemmomas and 1 ganglioneuroblastoma. Biochemical investigation was performed for all patients. Of the tuberculosis cases, 31 (91%) invaded with bilateral involvement, while 7 (9%) of the primary tumors invaded with bilateral involvement (P<0.001). Tuberculosis often showed calcification (20 of 34; 59%), whereas primary tumors infrequently showed calcification (6 of 74; 8%; P<0.001). Low attenuation in the center with peripheral rim enhancement was more commonly seen in tuberculosis (16 of 34; 47%) than in primary tumors (7 of 74; 9%; P<0.001). In the determination of tuberculosis, the highest sensitivity (91%) and accuracy (91%) were obtained with bilateral involvement, and the highest specificity (99%) was obtained with the contour preserved. In the determination of primary tumors using a combination of having unilateral involvement and being mass-like, the outcome was a sensitivity of 91%, specificity of 94% and accuracy of 92%. CT findings can differentiate tuberculosis from a primary tumor of the adrenal glands with high sensitivity and an acceptable specificity when combined with the endocrinological examination. (orig.)

  3. Initial assessment of the COMPASS/BeiDou-3: new-generation navigation signals

    Science.gov (United States)

    Zhang, Xiaohong; Wu, Mingkui; Liu, Wanke; Li, Xingxing; Yu, Shun; Lu, Cuixian; Wickert, Jens

    2017-10-01

    The successful launch of five new-generation experimental satellites of the China's BeiDou Navigation Satellite System, namely BeiDou I1-S, I2-S, M1-S, M2-S, and M3-S, marks a significant step in expanding BeiDou into a navigation system with global coverage. In addition to B1I (1561.098 MHz) and B3I (1269.520 MHz) signals, the new-generation BeiDou-3 experimental satellites are also capable of transmitting several new navigation signals in space, namely B1C at 1575.42 MHz, B2a at 1176.45 MHz, and B2b at 1207.14 MHz. For the first time, we present an initial characterization and performance assessment for these new-generation BeiDou-3 satellites and their signals. The L1/L2/L5 signals from GPS Block IIF satellites, E1/E5a/E5b signals from Galileo satellites, and B1I/B2I/B3I signals from BeiDou-2 satellites are also evaluated for comparison. The characteristics of the B1C, B1I, B2a, B2b, and B3I signals are evaluated in terms of observed carrier-to-noise density ratio, pseudorange multipath and noise, triple-frequency carrier-phase ionosphere-free and geometry-free combination, and double-differenced carrier-phase and code residuals. The results demonstrate that the observational quality of the new-generation BeiDou-3 signals is comparable to that of GPS L1/L2/L5 and Galileo E1/E5a/E5b signals. However, the analysis of code multipath shows that the elevation-dependent code biases, which have been previously identified to exist in the code observations of the BeiDou-2 satellites, seem to be not obvious for all the available signals of the new-generation BeiDou-3 satellites. This will significantly benefit precise applications that resolve wide-lane ambiguity based on Hatch-Melbourne-Wübbena linear combinations and other applications such as single-frequency precise point positioning (PPP) based on the ionosphere-free code-carrier combinations. Furthermore, with regard to the triple-frequency carrier-phase ionosphere-free and geometry-free combination, it is found

  4. FDG PET/CT imaging of desmoplastic small round cell tumor: findings at staging, during treatment and at follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Ostermeier, Austin; Snyder, Scott E.; Shulkin, Barry L. [St. Jude Children' s Research Hospital, Department of Radiological Sciences, MS 220, Memphis, TN (United States); McCarville, M.B. [St. Jude Children' s Research Hospital, Department of Radiological Sciences, MS 220, Memphis, TN (United States); College of Medicine, University of Tennessee Health Science Center, Department of Radiology, Memphis, TN (United States); Navid, Fariba [St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee Health Science Center, Department of Pediatrics, College of Medicine, Memphis, TN (United States)

    2015-08-15

    Desmoplastic small round cell tumor (DSRCT) is a very uncommon soft-tissue tumor of children and young adults. It has an aggressive course with generally poor survival. In general the assessment of tumor burden and response has relied upon CT or MRI. However these tumors are often metabolically active and can be evaluated using FDG PET/CT imaging. The purpose of this study was to determine the metabolic activity of desmoplastic small round cell tumors using FDG PET/CT imaging and the potential utility of FDG PET/CT in this disease. Eight patients (seven male, one female; ages 2-20 years, median 11 years) with confirmed DSRCT underwent 82 positron emission tomography/computed tomography (PET/CT) scans. PET/CT was used for initial staging (seven patients, eight scans), monitoring response to therapy (eight patients, 37 scans) and for surveillance of DSRCT recurrence (six patients, 37 scans). Each scan performed at diagnosis showed abnormally elevated uptake in the primary tumor. Five patients had abdominal pelvic involvement, and two of those also had thoracic disease. Six patients whose scans showed no abnormal sites of uptake at the end of therapy have had progression-free survivals of 2-10 years. One patient whose scan continued to show uptake during treatment died of disease 1.3 years from diagnosis. Another patient with persistent uptake remained in treatment 3 years after initial diagnosis. One surveillance scan identified recurrent disease. FDG PET/CT identified elevated metabolic activity in each patient studied. Despite our small sample size, FDG PET/CT scans appear useful for the management of patients with DSCRT. Patients whose studies become negative during or following treatment may have a prolonged remission. (orig.)

  5. The value of emergency CT studies in spontaneous rupture of hepatocellular carcinoma. Analysis for tumor protrusion and hemorrhagic ascites

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Makiko; Kobayashi, Hisashi; Ichikawa, Taro; Cho, Keiichi; Gemma, Kazuhito; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1997-12-01

    CT characteristics of spontaneous rupture of HCC (n=13) were reviewed retrospectively, and the value of emergency CT studies in this disease was evaluated. Especially, tumor protrusion ratio (TPR) and ascitic CT numbers were measured to for comparison with the data for unruptured HCCs and ordinary, (e.g., non-hemorrhagic) ascites (n=13). As a result, except for diffuse type HCCs, the TPR was significantly higher than for the unruptured HCCs. Nine cases had intraperitoneal HDAs, and the laterality of the HDAs corresponded with that of the ruptured tumors in 8 cases. Also, the ascitic CT numbers apart from the HDA were still higher than the ordinary ascites. Therefore, a high TPR, HDAs adjacent to the tumor, and elevated ascitic CT numbers are important CT manifestations indicating HCC rupture. Diffuse HCCs, however, require careful clinical evaluation. (author)

  6. The value of emergency CT studies in spontaneous rupture of hepatocellular carcinoma. Analysis for tumor protrusion and hemorrhagic ascites

    International Nuclear Information System (INIS)

    Ishihara, Makiko; Kobayashi, Hisashi; Ichikawa, Taro; Cho, Keiichi; Gemma, Kazuhito; Kumazaki, Tatsuo

    1997-01-01

    CT characteristics of spontaneous rupture of HCC (n=13) were reviewed retrospectively, and the value of emergency CT studies in this disease was evaluated. Especially, tumor protrusion ratio (TPR) and ascitic CT numbers were measured to for comparison with the data for unruptured HCCs and ordinary, (e.g., non-hemorrhagic) ascites (n=13). As a result, except for diffuse type HCCs, the TPR was significantly higher than for the unruptured HCCs. Nine cases had intraperitoneal HDAs, and the laterality of the HDAs corresponded with that of the ruptured tumors in 8 cases. Also, the ascitic CT numbers apart from the HDA were still higher than the ordinary ascites. Therefore, a high TPR, HDAs adjacent to the tumor, and elevated ascitic CT numbers are important CT manifestations indicating HCC rupture. Diffuse HCCs, however, require careful clinical evaluation. (author)

  7. Kontrastmittelverstärkte Magnet-Resonanz-Urographie unter forcierter Diurese - Stellenwert in der Differentialdiagnostik bei Obstruktionen des oberen Harntraktes

    Directory of Open Access Journals (Sweden)

    Jung P

    2001-01-01

    Full Text Available Die Magnet-Resonanz-Urographie (MRU ist ein relativ neues Verfahren in der Diagnostik des oberen Harntraktes. Das Ziel dieser Studie war der Vergleich der Aussagefähigkeit der MRU unter Gabe von Gadolinium und Furosemid und dem konventionellen Urogramm (IVU in der Diagnostik der Ursache von Obstruktionen im Bereich des Harnleiters. 82 Patienten mit im IVU nachgewiesener Obstruktion des oberen Harntraktes oder urographisch stummer Niere bei sonographisch nachgewiesener Dilatation wurden der MRU zugeführt. Die Bilder beider Untersuchungsmethoden wurden von voneinander unabhängigen Untersuchern befundet. Zwei Urologen befundeten die IVU-Bilder, zwei Radiologen die MRU-Bilder, die Radiologen kannten die IVU-Diagnose nicht. Bei unklarer Diagnose wurden weitere Untersuchungen wie Computertomographie, retrograde Pyelographie oder Ureteroskopie durchgeführt. Die Diagnosen waren: Harnleitersteine bei 72 Patienten, Harnleitertumore bei 8 Patienten und extraureterale Tumore bei 2 Patienten. Eine richtige Diagnose bei den Steinpatienten wurde durch IVU bei 49 von 72 Patienten und durch MRU bei 64 von 72 Patienten gestellt. In dieser Patientengruppe wurden durch die MRU zwei falsche Diagnosen gestellt. Fehlende Kontrastmittelausscheidung war der Hauptgrund für Versagen der IVU. 3 der 8 Patienten mit Harnleitertumoren wurden durch die IVU richtig dignostiziert, bei dreien wurde eine falsche Diagnose gestellt. Durch die MRU konnten in dieser Gruppe 7 von 8 Patienten korrekt diagnostiziert werden, es wurde keine falsche Diagnose erhoben. IVU wird zunächst die Standarduntersuchungstechnik zur Darstellung des oberen Harntraktes bleiben, aber durch diese Studie konnte die Möglichkeit gezeigt werden, die in der MRU in Kombination mit Gadolinium und Furosemid liegt. Die größte Bedeutung dieser Untersuchung liegt in der urographisch stummen Niere, bei Untersuchungen in der Schwangerschaft, bei Kindern und bei Patienten mit Kontrastmittelunverträglichkeit.

  8. Comparison of conventional and 3-dimensional computed tomography against histopathologic examination in determining pancreatic adenocarcinoma tumor size: Implications for radiation therapy planning

    International Nuclear Information System (INIS)

    Qiu Haoming; Wild, Aaron T.; Wang Hao; Fishman, Elliot K.; Hruban, Ralph H.; Laheru, Daniel A.; Kumar, Rachit; Hacker-Prietz, Amy; Tuli, Richard; Tryggestad, Erik; Schulick, Richard D.; Cameron, John L.; Edil, Barish H.; Pawlik, Timothy M.; Wolfgang, Christopher L.; Herman, Joseph M.

    2012-01-01

    Background and purpose: This study seeks to: (a) quantify radiologic-pathologic discrepancy for pancreatic adenocarcinoma by comparing tumor size on conventional computed tomography (C-CT) and 3-dimensional CT (3D-CT) to corresponding pathologic specimens; and (b) to identify clinico-pathologic characteristics predictive of radiologic-pathologic discrepancy to assist radiotherapy planning. Materials and methods: Sixty-three patients with pancreatic adenocarcinoma and preoperative C-CT and volume-rendered 3D-CT imaging within 6 weeks of resection were identified. Maximum tumor diameter (MTD) was measured on pathology, C-CT, and 3D-CT and compared for each patient as well as among different clinico-pathologic subgroups. Results: There was a trend toward C-CT underestimation of MTD compared to final pathology (p = 0.08), but no significant difference between 3D-CT MTD and pathology (p = 0.54). Pathologic tumor size was significantly underestimated by C-CT in patients with larger pathologic tumor size (>3.0 cm, p = 0.0001), smaller tumor size on C-CT ( 90 U/mL, p = 0.008), and location in the pancreatic head (p = 0.015). A model for predicting pathologic MTD using C-CT MTD and CA19-9 level was generated. Conclusions: 3D-CT may allow for more accurate contouring of pancreatic tumors than C-CT. Patients with the above clinico-pathologic characteristics may require expanded margins relative to tumor size estimates on C-CT during radiotherapy planning.

  9. CtBP2 overexpression promotes tumor cell proliferation and invasion in gastric cancer and is associated with poor prognosis.

    Science.gov (United States)

    Dai, Faxiang; Xuan, Yi; Jin, Jie-Jie; Yu, Shengjia; Long, Zi-Wen; Cai, Hong; Liu, Xiao-Wen; Zhou, Ye; Wang, Ya-Nong; Chen, Zhong; Huang, Hua

    2017-04-25

    C-terminal binding protein-2 (CtBP2), a transcriptional corepressor, has been reported to correlate with tumorigenesis and progression and predict a poor prognosis in several human cancers. However, few studies on CtBP2 in gastric cancer (GC) have been performed. In this research, we evaluated the correlations between CtBP2 expression and the clinicopathological characteristics, as well as prognosis of GC patients. The effects of silencing CtBP2 expression on GC cells biology activity were also assessed. The results showed that CtBP2 was overexpressed in GC tissues and closely correlated with poor differentiation, advanced tumor stage and poor prognosis in GC patients. CtBP2 induced epithelial-to-mesenchymal transition (EMT) and repressed PTEN to increase proliferation rate, migration, and invasion in GC cells. Silencing CtBP2 inhibited GC growth in nude mice model. In conclusion, CtBP2 is overexpressed in GC and may accelerate GC tumorigenesis and metastasis, which could represent an independent prognostic marker and promising therapeutic target for GC.

  10. Combined FDG-PET/CT for the detection of unknown primary tumors: systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Kwee, Thomas C.; Kwee, Robert M.

    2009-01-01

    The aim of this study was to systematically review and meta-analyze published data on the diagnostic performance of combined 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in the detection of primary tumors in patients with cancer of unknown primary (CUP). A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Methodological quality of the included studies was assessed. Reported detection rates, sensitivities and specificities were meta-analyzed. Subgroup analyses were performed if results of individual studies were heterogeneous. The 11 included studies, comprising a total sample size of 433 patients with CUP, had moderate methodological quality. Overall primary tumor detection rate, pooled sensitivity and specificity of FDG-PET/CT were 37%, 84% (95% CI 78-88%) and 84% (95% CI 78-89%), respectively. Sensitivity was heterogeneous across studies (P = 0.0001), whereas specificity was homogeneous across studies (P = 0.2114). Completeness of diagnostic workup before FDG-PET/CT, location of metastases of unknown primary, administration of CT contrast agents, type of FDG-PET/CT images evaluated and way of FDG-PET/CT review did not significantly influence diagnostic performance. In conclusion, FDG-PET/CT can be a useful method for unknown primary tumor detection. Future studies are required to prove the assumed advantage of FDG-PET/CT over FDG-PET alone and to further explore causes of heterogeneity. (orig.)

  11. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    Science.gov (United States)

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Variations in tumor size and position due to irregular breathing in 4D-CT: A simulation study

    International Nuclear Information System (INIS)

    Sarker, Joyatee; Chu, Alan; Mui, Kit; Wolfgang, John A.; Hirsch, Ariel E.; Chen, George T. Y.; Sharp, Gregory C.

    2010-01-01

    Purpose: To estimate the position and volume errors in 4D-CT caused by irregular breathing. Methods: A virtual 4D-CT scanner was designed to reproduce axial mode scans with retrospective resorting. This virtual scanner creates an artificial spherical tumor based on the specifications of the user, and recreates images that might be produced by a 4D-CT scanner using a patient breathing waveform. 155 respiratory waveforms of patients were used to test the variability of 4D-CT scans. Each breathing waveform was normalized and scaled to 1, 2, and 3 cm peak-to-peak motion, and artificial tumors with 2 and 4 cm radius were simulated for each scaled waveform. The center of mass and volume of resorted 4D-CT images were calculated and compared to the expected values of center of mass and volume for the artificial tumor. Intrasubject variability was investigated by running the virtual scanner over different subintervals of each patient's breathing waveform. Results: The average error in the center of mass location of an artificial tumor was less than 2 mm standard deviation for 2 cm motion. The corresponding average error in volume was less than 4%. In the worst-case scenarios, a center of mass error of 1.0 cm standard deviation and volume errors of 30%-60% at inhale were found. Systematic errors were observed in a subset of patients due to irregular breathing, and these errors were more pronounced when the tumor volume is smaller. Conclusions: Irregular breathing during 4D-CT simulation causes systematic errors in volume and center of mass measurements. These errors are small but depend on the tumor size, motion amplitude, and degree of breathing irregularity.

  13. CT imaging findings of neuroendocrine tumor arising from tailgut cyst: a case report

    International Nuclear Information System (INIS)

    Aydin, N.; Kara, T.; Kebapci, M.

    2012-01-01

    Full text: Introduction: We present a case of neuroendocrine tumor which is arisen from a tailgut cyst in a middle aged woman with its computed tomography (CT) imaging findings. Objective and tasks:The tailgut normally involutes by the eighth week of gestational age. If a tailgut rest proceeds, it may give rise to a tailgut cyst in the presacral space. Malign transformation of the tailgut cyst is very rare. Material and methods: A 35-year-old woman with a history of endometriosis admitted to our hospital for her routine control.An ultrasonography examination and contrast medium enhanced tomography of the abdomen and pelvis were performed. Results: CT showed multiple well-defined solid heterogen masses in presacral space. The patient underwent surgery. Pathology was reported as neuroendocrine tumor arising within tailgut cyst. Conclusion: Adenocarcinoma, neuroendocrine carcinoma, and sarcoma developing within the tailgut cyst has been reported. CT shows well-marginated presacral mass.If concurrent malignant transformation occurs, CT shows loss of margins and involvement of adjacent structures.Diagnosis of tailgut cyst is important because of it's malignant potential

  14. Quantitative characterization of liver tumor radiodensity in CT images: a phantom study between two scanners

    Science.gov (United States)

    Berman, Benjamin Paul; Li, Qin; McKenney, Sarah; Fricke, Stanley Thomas; Fang, Yuan; Gavrielides, Marios A.; Petrick, Nicholas

    2018-02-01

    Quantitative assessment of tumor radiodensity is important for the clinical evaluation of contrast enhancement and treatment response, as well as for the extraction of texture-related features for image analysis or radiomics. Radiodensity estimation, Hounsfield Units (HU) in CT images, can be affected by patient factors such as tumor size, and by system factors such as acquisition and reconstruction protocols. In this project, we quantified the measurability of liver tumor HU using a 3D-printed phantom, imaged with two CT systems: Siemens Somatom Force and GE Lightspeed VCT. The phantom was printed by dithering two materials to create spherical tumors (10, 14 mm) with uniform densities (90, 95, 100, 105 HU). Image datasets were acquired at 120 kVp including 15 repeats using two matching exposures across the CT systems, and reconstructed using comparable algorithms. The radiodensity of each tumor was measured using an automated matched-filter method. We assessed the performance of each protocol using the area under the ROC curve (AUC) as the metric for distinguishing between tumors with different radiodensities. The AUC ranged from 0.8 to 1.0 and was affected by tumor size, radiodensity, and scanner; the lowest AUC values corresponded to low dose measurements of 10 mm tumors with less than 5 HU difference. The two scanners exhibited similar performance >0.9 AUC for large lesions with contrast above 7 HU, though differences were observed for the smallest and lowest contrast tumors. These results show that HU estimation should be carefully examined, considering that uncertainty in the tumor radiodensity may propagate to quantification of other characteristics, such as size and texture.

  15. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  16. Comparison of 11C-choline-PET/CT and whole body-MRI for staging of prostate cancer

    International Nuclear Information System (INIS)

    Eschmann, S.M.; Rieger, A.; Mueller, M.; Bares, R.; Pfannenberg, A.C.; Aschoff, P.; Claussen, C.D.; Schlemmer, H.P.; Paulsen, F.; Anastasiadis, A.

    2007-01-01

    Aim of this study was to compare the diagnostic accuracy of positron emission tomography and computed tomography with 11 C-Choline (Cho-PET/CT) and whole body magneticresonance imaging (WB-MRI) for diagnostic work-up of prostate cancer. Patients, methods: We evaluated retrospectively 42 patients with untreated prostate cancer (n =17), or increasing levels of prostate-specific antigen (PSA) after curative therapy (n = 25) who had been investigated by both Cho-PET/CT and WB-MRI. MRI, CT, and PET images were separately analyzed by experienced radiologists or nuclear medicine experts, followed by consensus reading. Validation was established by histology, follow-up, or consensus reading. Results: 88/103 detected lesions were considered as malignant: 44 bone metastases, 22 local tumor, 15 lymph node metastases, 3 lung, and 3 brain metastases. One further lesion was located in the adrenal gland, which was a second tumor. Overall sensitivity, specificity and accuracy for Cho-PET/CT were 96.6%, 76.5%, and 93.3%, resp., and for WB-MRI 78.4%, 94.1%, and 81.0%, resp. 3 vertebral metastases had initially been missed by Cho-PET/CT and were found retrospectively. MRI identified 2 bone metastases and 1 lymph node metastasis after being informed about the results of Cho-PET/CT. Conclusions: Cho-PET/CT and WB-MRI both presented high accuracy in the detection of bone and lymph node metastases. The strength of MRI is excellent image quality providing detailed anatomical information whereas the advantage of Cho-PET/CT is high image contrast of pathological foci. (orig.)

  17. Ectopic ACTH and CRH co-secreting tumor localized by 68Ga-DOTA-TATE PET/CT

    Science.gov (United States)

    Papadakis, Georgios Z.; Bagci, Ulas; Sadowski, Samira M.; Patronas, Nicholas J.; Stratakis, Constantine A.

    2015-01-01

    Diagnosis of ectopic adrenocorticotropic hormone (ACTH) and corticotropin releasing hormone (CRH) co-secreting tumors causing Cushing syndrome (CS) is challenging, since these tumors are rare and their diagnosis is frequently confused with Cushing disease (CD), due to the effect of CRH on the pituitary. We report a case of a 21-year-old male who was referred to our institution with persistent hypercortisolemia and CS after undergoing unnecessary transsphenoidal surgery (TSS). 68Ga-DOTA-TATE PET/CT revealed increased tracer uptake in the thymus which was histologically proved to be neuroendocrine tumor (NET) staining positive for ACTH and CRH. Imaging with 18F-FDG PET/CT was not diagnostic. PMID:26018709

  18. CT and MR imaging findings of endocrine tumor of the pancreas according to WHO classification

    International Nuclear Information System (INIS)

    Rha, Sung Eun; Jung, Seung Eun; Lee, Kang Hoon; Ku, Young Mi; Byun, Jae Young; Lee, Jae Mun

    2007-01-01

    The pancreatic endocrine tumors are rare neuroendocrine tumors of the pancreas originating from totipotential stem cells or differentiated mature endocrine cells within the exocrine gland. Endocrine tumors are usually classified into functioning and non-functioning tumors and presents with a range of benignity or malignancy. In this article, we present the various CT and MR imaging findings of endocrine tumors of pancreas according to recent WHO classification

  19. Association between textural and morphological tumor indices on baseline PET-CT and early metabolic response on interim PET-CT in bulky malignant lymphomas.

    Science.gov (United States)

    Ben Bouallègue, Fayçal; Tabaa, Yassine Al; Kafrouni, Marilyne; Cartron, Guillaume; Vauchot, Fabien; Mariano-Goulart, Denis

    2017-09-01

    We investigated whether metabolic, textural, and morphological tumoral indices evaluated on baseline PET-CT were predictive of early metabolic response on interim PET-CT in a cohort of patients with bulky Hodgkin and non-Hodgkin malignant lymphomas. This retrospective study included 57 patients referred for initial PET-CT examination. In-house dedicated software was used to delineate tumor contours using a fixed 30% threshold of SUV max and then to compute tumoral metabolic parameters (SUV max, mean, peak, standard deviation, skewness and kurtosis, metabolic tumoral volume (MTV), total lesion glycolysis, and area under the curve of the cumulative histogram), textural parameters (Moran's and Geary's indices, energy, entropy, contrast, correlation derived from the gray-level co-occurrence matrix, area under the curve of the power spectral density, auto-correlation distance, and granularity), and shape parameters (surface, asphericity, convexity, surfacic extension, and 2D and 3D fractal dimensions). Early metabolic response was assessed on interim PET-CT using the Deauville 5-point scale and patients were ranked according to the Lugano classification as complete or not complete metabolic responders. The impact of the segmentation method (alternate threshold at 41%) and image resolution (Gaussian postsmoothing of 3, 5, and 7 mm) was investigated. The association of the proposed parameters with early response was assessed in univariate and multivariate analyses. Their added predictive value was explored using supervised classification by support vector machines (SVM). We evaluated in leave-one-out cross-validation three SVMs admitting as input features (a) MTV, (b) MTV + histological type, and (c) MTV + histology + relevant texture/shape indices. Features associated with complete metabolic response were low MTV (P = 0.01), low TLG (P = 0.003), high power spectral density AUC (P = 0.007), high surfacic extension (P = 0.006), low 2D fractal dimension (P

  20. Quantitative CT analysis for the preoperative prediction of pathologic grade in pancreatic neuroendocrine tumors

    Science.gov (United States)

    Chakraborty, Jayasree; Pulvirenti, Alessandra; Yamashita, Rikiya; Midya, Abhishek; Gönen, Mithat; Klimstra, David S.; Reidy, Diane L.; Allen, Peter J.; Do, Richard K. G.; Simpson, Amber L.

    2018-02-01

    Pancreatic neuroendocrine tumors (PanNETs) account for approximately 5% of all pancreatic tumors, affecting one individual per million each year.1 PanNETs are difficult to treat due to biological variability from benign to highly malignant, indolent to very aggressive. The World Health Organization classifies PanNETs into three categories based on cell proliferative rate, usually detected using the Ki67 index and cell morphology: low-grade (G1), intermediate-grade (G2) and high-grade (G3) tumors. Knowledge of grade prior to treatment would select patients for optimal therapy: G1/G2 tumors respond well to somatostatin analogs and targeted or cytotoxic drugs whereas G3 tumors would be targeted with platinum or alkylating agents.2, 3 Grade assessment is based on the pathologic examination of the surgical specimen, biopsy or ne-needle aspiration; however, heterogeneity in the proliferative index can lead to sampling errors.4 Based on studies relating qualitatively assessed shape and enhancement characteristics on CT imaging to tumor grade in PanNET,5 we propose objective classification of PanNET grade with quantitative analysis of CT images. Fifty-five patients were included in our retrospective analysis. A pathologist graded the tumors. Texture and shape-based features were extracted from CT. Random forest and naive Bayes classifiers were compared for the classification of G1/G2 and G3 PanNETs. The best area under the receiver operating characteristic curve (AUC) of 0:74 and accuracy of 71:64% was achieved with texture features. The shape-based features achieved an AUC of 0:70 and accuracy of 78:73%.

  1. Study of CT-guided iodine-125 implantation in the treatment of rabbit VX2 tumor

    International Nuclear Information System (INIS)

    He Kewu; Gao Bin; Li Jiajia

    2008-01-01

    Objective: To evaluate the effect of CT-guided iodine-125 seed( 125 I) implantation to rabbit model VX2 tumor cell apoptosis. Methods: VX2 tumor cells were implanted into muscle of 40 rabbits legs, 3 weeks later, as the diameter of tumor reached 2 cm available for test. Randomly selected the sampling tumor on one leg of rabbit as for the test team and tumor on the contralateral leg as for control team. Under CT guidance, 125 I seeds were implanted into 20 tumor lesions of the test team, and hollow seeds were implanted into 20 tumor lesions of the control team. Instantly, 72 h, 1, 2, 3 w after operation, percutaneous tumor tissue sampling was done 0.5-1.0 cm and 1.0-1.5 cm away from seed implanted site under CT guidance; and apoptosis was investigated by FCM. Results: Instantly, 72 h, 1, 2, 3 w after treatment with iodine-125 ( 125 I) implantation, the tissue sampling away from seed 0.5-1.0 cm showed the apoptosis rates of control team and test team were respectively as follows: (5.43±0.67)% and (5.48±0.66)%, (P>0.05), (5.45±0.58)% and (11.60±0.87)%, (P O.05)of the control team and test team. Conclusions: 125 I seeds implantation can induce tumor cell apoptosis, beginning at 72 h and reached peak at 2 w and kept the high level here afterword. The apoptosis rate descended rapidly along with the increase of distance away from the 125 I seedling. (authors)

  2. Malignant phyllodes tumor of the breast metastasizing to the vulva: {sup 18}F FDG PET CT Demonstrating rare metastasis from a rare tumor

    Energy Technology Data Exchange (ETDEWEB)

    Khangembam, Bang Kim Chand Ra; Sharma, Punit; Singla, Su Has; Singhal, Abinav; Dhull, Varun Singh; Bal, Chand Rasek Har; Kumar, Rakesh [All India Institute of Medical Sciences, New Delhi (India)

    2012-09-15

    Phyllodes tumors are extremely rare fibroepithelial neoplasms accounting for 0.3 to 0.5% of all female breast tumors with an incidence of 2.1 per 1 million women. They are classified histologically into benign, borderline and malignant varieties. The majority of them are benign, with only 25% being malignant. Surgery remains the mainstay of treatment. One characteristic is that although the malignant variety tends to metastasize and recur, the benign form has also been found to behave in a similar manner. Benign phyllodes tumor has a 21% risk of local recurrence, while that of the malignant variety ranges from 20 to 32%. In patients with malignant phyllodes tumor, the rate of distant metastases ranges from 25 to 40%. The most frequent sites of distant metastasis is uncommon as this tumor spreads by hematogeneous route. Other sites for distant metastasis have been reported sporadically, including the duodenum, pancreas, brain, nasal cavity, forearm, parotid, skin, oral cavity, skeletal muscle, mandible and maxilla. We present a rare case of recurrent malignant phyllodes tumor with metastasis to the vulva, which has not been reported in the literature to the best of our knowledge. A 49 year old female who had undergone lumpectomy and locoregional radiotherapy 1 year previously for malignant phyllodes tumor of the right breast presented with difficulty in breathing and cervical lymphadenopathy. Chest X ray showed multiple pulmonary nodules suggestive of metastasis. She was referred for restaging with 18F fluorodeoxyglucose (FDG)positron emission tomography computed tomography (PET CT)FDG PET CT. Maximum intensity projection (MIP)PET images revealed multiple FDG avid enlarged cervical lymph nodes, bilateral pulmonary nodules along with left pleural effusion and extensive bone marrow metastases. The interesting finding was an intensely FDG avid (SUV{sup max}-21.4)subcutaneous soft tissue density lesion (measuring 2.0x2.2x2.0cm)in the vulva, which was later proved to be

  3. Improved automated production of 18F-FMISO and its tumor hypoxia imaging by Micro-PET/CT

    International Nuclear Information System (INIS)

    Wang Mingwei; Zhang Yongping; Zheng Yujia; Bao Xiao; Zheng Yingjian

    2013-01-01

    Background: 1-H-1-(3-[ 18 F]fluoro-2-hydroxypropyl)-2-nitroimidazole ( 18 F-FMISO) is a specific molecular imaging probe for tumor hypoxia imaging, and its PET/CT imaging has an important clinical value for planning cancer radiotherapy target volume. Purpose: This study aimed to develop an improved, automated production of 18 F-FMISO and to perform Micro-PET/CT imaging of tumor hypoxia. Methods: Based on the labeling precursor NITTP and a simple 'one-pot' method, an upgraded Explora GN module together with Explora LC was adopted to run radiofluorination (NITTP (10 mg), MeCN (1.0 mL), 120℃, 5.0 min), hydrolysis (HCI (1.0 mol/L, 1.0 mL), 130℃, 8.0 min) and high performance liquid chromatography (HPLC) purification to produce 18 F-FMISO automatically. Moreover, Radio-HPLC and Radio-TLC were applied for the quality control, and Micro-PET/CT scanner for hypoxia imaging of SW1990 pancreatic tumor-bearing mice. Results: As results, 18 F-FMISO was obtained with the synthesis time for about 65 min, the radiochemical yield of (30±5.0)% (no decay corrected, n=20), the radiochemical purity of above 99%, the specific activity of (2.04±0.17)x10 11 Bq·μmol -1 , plus with the enhanced chemical purity. Moreover, MicroPET/CT imaging showed that 18 F-FMISO presented whole-body distribution in SW1990 tumor-bearing mice, and the optimized time point for tumor hypoxia imaging was 3 h post injection with the uptake ratios of tumor-to-muscle of 3.00±0.08. Conclusion: In sum, we developed an improved, automated production of 18 F-FMISO with high performance liquid chromatography purification, high radiochemical yield, high specific activity and high reliability , and also verified its MicroPET/CT imaging of tumor hypoxia for providing experimental reference data. (authors)

  4. Computer-aided analysis of CT images for the differentiation of cerebral tumors

    International Nuclear Information System (INIS)

    Michalik, M.; Michalik, S.; Bornholdt, F.

    1988-01-01

    For the integration of CT imaging into the differential diagnostics of intracranial space occupations, the selection and description of characteristics facilitating a good discrimination of serveral classes of tumors becomes a very important task. From images of 93 patients with the most frequent brain tumors the optimal set of characteristics was determined. The four most significant characteristics for the differentiation of brain tumors are 'uptake of contrast medium by the tumor', 'deliniation of the tumor contours', 'progression of the tumor' and the 'average tumor density after administration of contrast media'. Very good results were obtained for the differentiation of menigneomas with and without anaplasia and for the differentiation of meningeomas from all other tumors examined. The differentiation of the degree of malignancy for various gliomatous tumors was difficult. An accurate reclassification with the computer program was obtained for 83.4% of all tumors. (author)

  5. Using 18F FDG PET/CT to Detect an occult Mesenchymal Tumor Causing Oncogenic Osteomalacia

    International Nuclear Information System (INIS)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Yong Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Lee, Jong Doo; Kang, Won Jun

    2011-01-01

    Oncogenic osteomalacia is a rare paraneoplastic syndrome characterized by renal phosphate excretion, hypophosphatemia, and osteomalacia. This syndrome is often caused by tumors of mesenchymal origin. Patients with oncogenic osteomalacia have abnormal bone mineralization, resulting in a high frequency of fractures. Tumor resection is the treatment of choice, as it will often correct the metabolic imbalance. Although oncogenic osteomalacia is a potentially curable disease, diagnosis is difficult and often delayed because of the small size and sporadic location of the tumor. Bone scintigraphy and radiography best characterize osteoma lacia; magnetic resonance imaging findings are nonspecific. Here, we report a case of oncogenic osteomalacia secondary to a phosphaturic mesenchymal tumor that was successfully detected by 18F fluorodeoxyglucose positron emission tomography/computed tomography ( 18F FDG PET/CT). This case illustrates the advantages of 18F FDG PET/CT in detecting the occult mesenchymal tumor that causes oncogenic osteomalacia.

  6. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  7. CT staging of renal cell carcinoma using the revised 1997 TNM staging criteria: in comparison with the previous one

    International Nuclear Information System (INIS)

    Sung, Deuk Jae; Kim, Yun Hwan; Chung, Hwan Hoon; Chung, Kyoo Byung; Suh, Won Hyuck

    2001-01-01

    To assess the accuracy of preoperative CT staging of RCC and to compare the relationship between T stage and the incidence of metastasis on the basis of the old (1992) and the new (1997) UICC and AJCC tumor classification system. In 112 cases of surgically resected RCC, the stagings of preoperative CT scans were determined retrospectively by two radiologists and were compared with the results of pathologic examinations. In 70 cases which had been followed up over three years after surgery, the incidence of metastasis at initial diagnosis and during the follow-up period was assessed. All cases were reconsidered, and using the old and the new TNM classification, the incidence of metastasis was compared. According to the old TNM classification, 5 cases (4%) were staged at T1, 73(65%) at T2, 21(19%) at T3a, 9(8%) at T3b, 0 at T3c, and 4(4%) at T4. Using the new TNM classification, we also staged 54 cases (48%) at T1 and 24(21%) at T2. Overall, using this new classification, CT correctly staged 79% of patients (88/112) overstaged 15%(17/112) and understaged 6%(7/112). CT had a sensitivity of 84% and specificity of 91% in new T1 tumors, 71% and 95%, respectively, in new T2 tumors, 69% and 88% in T3a tumors, 78% and 98% in T3b tumors, and 75% and 99% in T4 tumors. CT had a sensitivity of 44% and a specificity of 99% in old T1 tumors, and 82% and 71%, respectively, in old T2 tumors. The incidence of metastasis in CT-staged (cT) tumors was 0% (0/4) in old cT1, 8% (3/39) in new cT1, 29% (4/14) in new cT2, 67% (6/9) in cT3a, and 75% (6/8) in cT3b. In the staging of T1 tumors, CT is more sensitive when the new TNM classification is used. Even though the cut off point between T1 and T2 tumors had been in creased from 2.5 to 7.0 cm, T1 tumors staged according to the new system did not show a significantly higher incidence of metastasis than those staged according to the old

  8. Multimodality functional imaging of spontaneous canine tumors using 64Cu-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    International Nuclear Information System (INIS)

    Hansen, Anders E.; Kristensen, Annemarie T.; Law, Ian; McEvoy, Fintan J.; Kjær, Andreas; Engelholm, Svend A.

    2012-01-01

    Purpose: To compare the distribution and uptake of the hypoxia tracer 64 Cu-diacetyl-bis(N 4 -methylthiosemicarbazone) ( 64 Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition 64 Cu-ATSM distribution over time was evaluated. Methods and materials: Nine spontaneous cancer-bearing dogs were prospectively enrolled. FDG (1 h pi.) and 64 Cu-ATSM (3 and 24 h pi.) PET/CT were performed over three consecutive days. DCE-pCT was performed on day 2. Tumor uptake of FDG and 64 Cu-ATSM was assessed semi-quantitatively and the distribution of FDG, 64 Cu-ATSM and CT perfusion parameters correlated. Results: 64 Cu-ATSM distribution on scans performed 24 h apart displayed moderate to strong correlation; however, temporal changes were observed. The spatial distribution pattern of 64 Cu-ATSM between scans was moderately to strongly positively correlated to FDG, whereas the correlation of CT perfusion parameters to FDG and to 64 Cu-ATSM yielded more varying results. Conclusions: 64 Cu-ATSM uptake was positively correlated to FDG. 64 Cu-ATSM was found to be relatively stable between PET scans performed at different time points, important temporal changes were however observed in hypo-perfused regions. These findings potentially indicate that prolonged uptake periods for 64 Cu-ATSM imaging may be needed. Although a moderate to strong correlation between 64 Cu-ATSM and FDG PET/CT is observed, the two tracers provide different biological information with an overlapping spatial distribution.

  9. Study on the correlation between VEGF and peritumoral edema and tumor border in astrocytoma by CT

    International Nuclear Information System (INIS)

    Ye Yuxiang; Tan Siping; Liu Bo; Liu Guorui; Zhen Zhichao; Fan Miao

    2004-01-01

    Objective: To study the correlation between VEGF and peritumoral edema and tumor border in human astrocytoma, investigate the significance of its CT features in molecular-biology. Methods: The VEGF was examined by means of SP immunohistochemical technique in 52 cases of astrocytoma proved by pathology. The correlation of tumor VEGF with peritumoral edema, and tumor border was analyzed. Results: The peritumoral edema, tumor border and mass effect of astrocytoma was positively correlated with its VEGF. The VEGF increased with peritumoral edema and mass effect (P<0.01). VEGF were significantly higher in uncertain border group than those the clear border group (P<0.05), which VEGF were 69.2 ± 19.0. Conclusion: The over expression of VEGF obviously effect CT features in astrocytoma, such as peritumoral edema and tumor border

  10. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  11. The relation of CT-determined tumor parameters and local and regional outcome of tonsillar cancer after definitive radiation treatment

    International Nuclear Information System (INIS)

    Hermans, Robert; Op de beeck, Katya; Bogaert, Walter van den; Rijnders, Alexis; Staelens, Lorenzo; Feron, Michel; Bellon, Erwin

    2001-01-01

    Purpose: To investigate the value of CT-derived tumor parameters as predictor of local and regional outcome of tonsillar squamous cell carcinoma treated by definitive radiation therapy. Methods and Materials: The pretreatment CT studies of 112 patients with tonsillar squamous cell carcinoma were reviewed. After redigitizing the films, primary and nodal tumor volume was calculated with the summation-of-areas technique. The nodal CT aspect was graded using a 3-point scale (homogenous, inhomogeneous, and necrotic). Mean follow-up time was 33 months. Actuarial statistical analysis of local and regional outcome was done for each of the covariates; multivariate analysis was performed using Cox's proportional hazards model. Results: In the actuarial analysis, CT-determined primary tumor volume was significantly correlated with local recurrence rate (p<0.05) when all patients were considered, but primary tumor volume did not predict local control within the T2, T3, and T4 category. CT-determined nodal volume was significantly related to regional outcome (p<0.01), but nodal density was not. Total tumor volume was not significantly related to locoregional outcome (p=0.1). In the multivariate analysis, the T and N categories were the independent predictors of local and regional outcomes, respectively. Conclusion: Compared to other head-and-neck sites, primary and nodal tumor volume have only marginal predictive value regarding local and regional outcome after radiation therapy in tonsillar cancer

  12. A prospective trial comparing FDG-PET/CT and CT to assess tumor response to cetuximab in patients with incurable squamous cell carcinoma of the head and neck

    International Nuclear Information System (INIS)

    Adkins, Douglas; Ley, Jessica; Dehdashti, Farrokh; Siegel, Marilyn J; Wildes, Tanya M; Michel, Loren; Trinkaus, Kathryn; Siegel, Barry A

    2014-01-01

    Computed tomography (CT), the standard method to assess tumor response to cetuximab in incurable squamous cell carcinoma of the head and neck (SCCHN), performs poorly as judged by the disparity between high disease control rate (46%) and short time to progression (TTP) (70 days). F-18 fluorodeoxyglucose positron emission tomography (FDG-PET)/CT is an alternative method to assess tumor response. The primary objective of this prospective trial was to evaluate the metabolic response of target lesions, assessed as the change in maximum standardized uptake value (SUV max ) on FDG-PET/CT before and after 8 weeks (cycle 1) of cetuximab. Secondary objectives were to compare tumor response by CT (RECIST 1.0) and FDG-PET/CT (EORTC criteria) following cycle 1, and determine TTP with continued cetuximab administration in patients with disease control by CT after cycle 1 but stratified for disease control or progression by FDG-PET/CT. Among 27 patients, the mean percent change of SUV max of target lesions after cycle 1 was −21% (range: +72% to −81%); by FDG-PET/CT, partial response (PR)/stable disease (SD) occurred in 15 patients (56%) and progression in 12 (44%), whereas by CT, PR/SD occurred in 20 (74%) and progression in 7 (26%). FDG-PET/CT and CT assessments were discordant in 14 patients (P = 0.0029) and had low agreement (κ = 0.30; 95% confidence interval [CI]: 0.12, 0.48). With disease control by CT after cycle 1, median TTP was 166 days (CI: 86, 217) if the FDG-PET/CT showed disease control and 105 days (CI: 66, 159) if the FDG-PET/CT showed progression (P < 0.0001). Median TTP of the seven patients whose post cycle 1 CT showed progression compared to the 12 whose FDG-PET/CT showed progression were similar (53 [CI: 49, 56] vs. 61 [CI: 50, 105] days, respectively). FDG-PET/CT may be better than CT in assessing benefit of cetuximab in incurable SCCHN

  13. Correlation of elvated tumor markers and hepatic and nodal metastases on CT in postgastrectomy patients for gastric cancer

    International Nuclear Information System (INIS)

    Lee, Hwa Jin; Park, Won Kyu; Seong, Ki Ho; Cho, Hyun Chul; Chang, Jae Chun; Park, Bok Hwan; Song, Sun Kyo

    1997-01-01

    The evaluation of tumor recurrence or metastasis in postgastrectomy cancer patients usually depends on a serum tumor marker test or radiologic study, but in both cases, accuracy is difficult to determine. The purpose of this study was to evaluate the relationship between abdominal CT and serum tumor markers. In 337cases involving 226 patients who had undergone curative surgery for gastric cancer, we compared serum tumor markers and CT for the evaluation of metastasis. Amoong these 337 cases, CEA level was measured in 317, CA 19-9 level in 166,and both of these in 146. The cutoff level for serum carcinoembryonic antigen (CEA) and CA19-9 were 10ng/ml and 33U/ml, respectively. CEA level was elevated in 59 of 317 cases(18.6%) and that of CA 19-9 in 58 of 166(34.9%). Slightly higher overall senstivity and specificity was observed for CEA than for CA19-9 (72.9% vs 67.2%, 83.3% vs 70.4%, respectively). Among the total of 337 cases, liver or lymph node metastases were detected in 91 cases (27.0%) on CT. Negative predictive value was significantly higher in CEA than in CA19-9 (93.1% vs 80%, respectively)(p<0.01), but positive predictive value was lower (50% vs 54.9%, respectively). On CT scan, there was a significant relationship between serum tumor marker level and hepatic and nodal metastasis ; specificity and positivity of serum tumor markers were both higher than senstivity and negativity. Follow-up CT less useful when tumor markers levels are not elevated, but when these are elevated in postgastrectomy cancer patients, meticulous radiologic evaluation is necessary for the early detection of residual or recurrent tumors

  14. Biogenic Emission Inventory System (BEIS)

    Science.gov (United States)

    Biogenic Emission Inventory System (BEIS) estimates volatile organic compound (VOC) emissions from vegetation and nitric oxide (NO) emission from soils. Recent BEIS development has been restricted to the SMOKE system

  15. Molecular imaging of neuroendocrine tumors using {sup 68}Ga-labeled peptides (Somatostatin receptor PET/CT); Molekulare Bildgebung neuroendokriner Tumoren mit {sup 68}Ga-markierten Peptiden (Somatostatinrezeptor-PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R.P.; Prasad, V. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Hoersch, D. [Zentralklinik Bad Berka GmbH (Germany). Klinik fuer Innere Medizin, Gastroenterologie, Onkologie, Endokrionologie

    2009-06-15

    Receptor PET/CT using {sup 68}Ga-labeled somatostatin analogues (DOTA-NOC, DOTA-TOC or DOTA-TATE) enables the highly sensitive molecular imaging of neuroendocrine tumors (NETs) based on the expression of somatostatin receptors and even the detection of receptor subtypes. Our experience after more than 3000 studies shows that receptor PET/CT has a significantly higher tumor detection rate than conventional scintigraphy (even in SPECT/CT technique), and that tumor lesions can be very accurately localized. By calculating standardized uptake values (SUV) - which are reproducible and investigator-independent - patients can be selected for peptide receptor radiotherapy and also the course after therapy can be controlled. Receptor-PET/CT is the most sensitive imaging modality for the detection of unknown primary tumors (CUP syndrome), which is especially true for the detection of neuroendocrine tumors of the pancreas and small bowel; whole-body staging (''one stop shop'') as well as restaging and selection of patients for peptide receptor radiotherapy can be performed using a patient-friendly procedure (examination finished within one hour) exposing the patient to less radiation than whole-body CT scanning. The {sup 68}Ge/{sup 68}Ga generator has proved very reliable over the years - even in a hospital environment. The effective costs for {sup 68}Ga labeled somatostatin analogues might be less than for scintigraphic agents, provided a certain number of studies per year are performed. The development of new tumor-specific peptides as well as of other DOTA- or NOTA-coupled radiopharmaceuticals opens a new avenue into the future: finally, the {sup 68}Ga generator could play a similar important role for PET/CT as did the {sup 99m}Tc-Generator for conventional gamma camera imaging over the last decades. (orig.)

  16. Estimation of lung tumor position from multiple anatomical features on 4D-CT using multiple regression analysis.

    Science.gov (United States)

    Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro

    2017-09-01

    To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Die Bandscheibenprothese bei schmerzhafter Diskusdegeneration

    Directory of Open Access Journals (Sweden)

    Ogon M

    2004-01-01

    Full Text Available Bandscheibenprothesen sind indiziert bei Patienten mit einer schmerzhaften Bandscheibendegeneration, einer sogenannten DDD (degenerative disc disease, bei gut erhaltenen Facettengelenken. Kontraindikationen stellen eine Instabilität, eine Spondylarthrose, eine spinale Stenose und eine Osteoporose dar. Bei 19 Patienten mit einem Follow-up von mindestens 12 Monaten fand sich eine durchschnittliche Verbesserung des Oswestry Disability Index von präoperativ 50,8 auf 19,8. Der SF-36 Score zur Erfassung der Lebensqualität besserte sich von 31,5 auf 48,8 (Physical Component Summary Score bzw. von 37,8 auf 44,5 (Mental Component Summary Score im 1-Jahres-Follow-up. Nachhaltige Komplikationen traten nicht auf. Bandscheibenprothesen können heute bei Patienten mit therapieresistenten Kreuzschmerzen als gute Alternative zu einer Wirbelfusion angesehen werden.

  18. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  19. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  20. The diagnosis and therapeutic gain using US, CT and MRI. Submucosal tumors in stomach and duodenum

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Shinichi; Nawano, Shigeru; Tajiri, Hisao; Boku, Narikazu; Muto, Manabu; Ohtsu, Atsushi; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Moriyama, Noriyuki

    1999-02-01

    The usefulness of the ultrasonography (US), the computed tomography (CT) and the magnetic resonance imaging (MRI) was examined. The subjects were 19 patients with submucosal leiomyoma and leiomyosarcoma in the stomach and duodenum which had surgery and were histologically diagnosed in the National Cancer Center Hospital. The detectability of the primary foci was 50% (8/16) in US, and 93% (13/14) in EUS (the endoscopic ultrasonography) which makes the structure of the stomach wall and the continuity of tumors clear. CT could detect the primary foci in 94% (16/17) and was excellent to know not only the presence of the remote metastases but also the exact size and expanse of the tumors. In all cases of leiomyoma, tumors were leiomyosarcoma when the internal structure was diagnosed to be heterogeneous by both EUS and CT, or either of them. The qualitative image diagnosis is not always easy in gastrointestinal submucosal tumors, but it is important to generally diagnose by the combination with several examinations in order to select the suitable therapeutic method. (K.H.)

  1. The value of conventional tomography and CT in the diagnosis of bronchial tumors

    International Nuclear Information System (INIS)

    Mayr, B.; Ingrisch, H.; Haeussinger, K.; Sunder-Plassmann, L.; Huber, R.

    1988-01-01

    66 patients with suspected bronchial tumors were examined by conventional tomography and by CT. The results were evaluated separately by two radiologists (A and B). All diagnoses were confirmed by bronchoscopy or surgery. In evaluating individual bronchi, conventional tomography had a sensitivity of 88% (A) or 87% (B) and a specificity of 97% (A) or 95% (B); CT had a sensitivity of 95% (A and B) and a specificity of 99% (A and B). If CT is available, our experience indicates that conventional tomography is no longer indicated. (orig.) [de

  2. Sequencing of chemotherapy (CT) and radiotherapy (RT) following conservative surgery (CS) for patients with early-stage breast cancer: results of a randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Recht, A; Come, SE; Silver, B; Gelman, RS; Hayes, DF; Shulman, LN; Henderson, IC; Harris, JR

    1995-07-01

    Purpose: To determine the effects of different sequences of CT and RT following CS for pts with clinical Stage I or II breast carcinoma. Methods and Materials: From 6/84-12/92, 244 pts were randomized following CS to receive CT (4 cycles of CAMFP at 3-wk intervals) either before or after RT. Median pt age was 45 yrs (range, 20-68). 164 pts were pre-, 18 pts peri-, and 62 pts were postmenopausal. 209 pts were node-positive (61 had 4 or more positive nodes); after 6/88, 35 selected node-negative pts were also included. 45 Gy was prescribed to the entire breast, followed by a boost of 16 Gy; nodal RT was optional. The medians ( and ranges) of the surgery-radiotherapy interval (SRI) according to assigned arm were: RT-first, 36 days (14-234); CT-first, 126 days (98-185). Drug doses were based on ideal body weight. Doses (per square meter) and schedule were: methotrexate, 200 mg, d.1 and 15; leucovorin, 10 mg, q6H x 12, start d.2 and 16; 5-fluorouracil, 500 mg, d.1; cyclophosphamide, 500 mg, d.1; prednisone, 40 mg/day x 5d, start d.1; and doxorubicin, 45 mg, d.3. All except leucovorin and prednisone were given by IV bolus. Dose reductions were based on the granulocyte nadir from the previous cycle, with an attempt to reescalate doses in subsequent cycles. Tamoxifen 10 mg BID was prescribed to postmenopausal pts with ER+ tumors following both RT and CT. 4 pts were ineligible due to prior malignancies, 2 pts on the RT-first arm refused their assigned sequence and received CT first, 2 pts on the RT-first arm and 1 pt on the CT-first arm refused to start or complete CT, 1 pt on the CT-arm underwent elective mastectomy prior to starting RT, and 1 pt on each arm received nonprotocol CT. Possible prognostic factors including age, menopausal status, ERP status, nodal status, and lymphatic vessel invasion were distributed nearly uniformly between the 2 arms. There was an excess of pts with EIC-positive tumors on the RT-first arm (25%) compared to the CT-first arm (11%) (p-bar=0

  3. Sequencing of chemotherapy (CT) and radiotherapy (RT) following conservative surgery (CS) for patients with early-stage breast cancer: results of a randomized trial

    International Nuclear Information System (INIS)

    Recht, A; Come, SE; Silver, B; Gelman, RS; Hayes, DF; Shulman, LN; Henderson, IC; Harris, JR

    1995-01-01

    Purpose: To determine the effects of different sequences of CT and RT following CS for pts with clinical Stage I or II breast carcinoma. Methods and Materials: From 6/84-12/92, 244 pts were randomized following CS to receive CT (4 cycles of CAMFP at 3-wk intervals) either before or after RT. Median pt age was 45 yrs (range, 20-68). 164 pts were pre-, 18 pts peri-, and 62 pts were postmenopausal. 209 pts were node-positive (61 had 4 or more positive nodes); after 6/88, 35 selected node-negative pts were also included. 45 Gy was prescribed to the entire breast, followed by a boost of 16 Gy; nodal RT was optional. The medians ( and ranges) of the surgery-radiotherapy interval (SRI) according to assigned arm were: RT-first, 36 days (14-234); CT-first, 126 days (98-185). Drug doses were based on ideal body weight. Doses (per square meter) and schedule were: methotrexate, 200 mg, d.1 and 15; leucovorin, 10 mg, q6H x 12, start d.2 and 16; 5-fluorouracil, 500 mg, d.1; cyclophosphamide, 500 mg, d.1; prednisone, 40 mg/day x 5d, start d.1; and doxorubicin, 45 mg, d.3. All except leucovorin and prednisone were given by IV bolus. Dose reductions were based on the granulocyte nadir from the previous cycle, with an attempt to reescalate doses in subsequent cycles. Tamoxifen 10 mg BID was prescribed to postmenopausal pts with ER+ tumors following both RT and CT. 4 pts were ineligible due to prior malignancies, 2 pts on the RT-first arm refused their assigned sequence and received CT first, 2 pts on the RT-first arm and 1 pt on the CT-first arm refused to start or complete CT, 1 pt on the CT-arm underwent elective mastectomy prior to starting RT, and 1 pt on each arm received nonprotocol CT. Possible prognostic factors including age, menopausal status, ERP status, nodal status, and lymphatic vessel invasion were distributed nearly uniformly between the 2 arms. There was an excess of pts with EIC-positive tumors on the RT-first arm (25%) compared to the CT-first arm (11%) (p-bar=0

  4. Hepatic Radiofrequency Ablation–induced Stimulation of Distant Tumor Growth Is Suppressed by c-Met Inhibition

    Science.gov (United States)

    Kumar, Gaurav; Moussa, Marwan; Wang, Yuanguo; Rozenblum, Nir; Galun, Eithan; Goldberg, S. Nahum

    2016-01-01

    Purpose To elucidate how hepatic radiofrequency (RF) ablation affects distant extrahepatic tumor growth by means of two key molecular pathways. Materials and Methods Rats were used in this institutional animal care and use committee–approved study. First, the effect of hepatic RF ablation on distant subcutaneous in situ R3230 and MATBIII breast tumors was evaluated. Animals were randomly assigned to standardized RF ablation, sham procedure, or no treatment. Tumor growth rate was measured for 3½ to 7 days. Then, tissue was harvested for Ki-67 proliferative indexes and CD34 microvascular density. Second, hepatic RF ablation was performed for hepatocyte growth factor (HGF), vascular endothelial growth factor (VEGF), and c-Met receptor expression measurement in periablational rim, serum, and distant tumor 24 hours to 7 days after ablation. Third, hepatic RF ablation was combined with either a c-Met inhibitor (PHA-665752) or VEGF receptor inhibitor (semaxanib) and compared with sham or drug alone arms to assess distant tumor growth and growth factor levels. Finally, hepatic RF ablation was performed in rats with c-Met–negative R3230 tumors for comparison with the native c-Met–positive line. Tumor size and immunohistochemical quantification at day 0 and at sacrifice were compared with analysis of variance and the two-tailed Student t test. Tumor growth curves before and after treatment were analyzed with linear regression analysis to determine mean slopes of pre- and posttreatment growth curves on a per-tumor basis and were compared with analysis of variance and paired two-tailed t tests. Results After RF ablation of normal liver, distant R3230 tumors were substantially larger at 7 days compared with tumors treated with the sham procedure and untreated tumors, with higher growth rates and tumor cell proliferation. Similar findings were observed in MATBIII tumors. Hepatic RF ablation predominantly increased periablational and serum HGF and downstream distant tumor

  5. Inclusion of PET-CT into planning of primary or neoadjuvant chemoradiotherapy of esophageal cancer improves prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, Jan-Christopher; Vaupel, Peter; Schmidberger, Heinz; Mayer, Arnulf [University Medical Center, Department of Radiation Oncology and Radiotherapy, Mainz (Germany); Wollschlaeger, Daniel [University Medical Center, Institute of Medical Biostatistics, Epidemiology and Informatics (IMBEI), Mainz (Germany); Miederer, Matthias [University Medical Center, Department of Nuclear Medicine, Mainz (Germany); Moehler, Markus [University Medical Center, Department of Internal Medicine I, Mainz (Germany)

    2017-10-15

    PET-CT is widely used for both the staging and planning of primary or neoadjuvant chemoradiotherapy for esophageal cancer. Inclusion of PET-CT information into radiotherapy planning often leads to substantial modifications of the target volume. In the case of detection of distant metastases, it may also result in a switch to a palliative treatment approach. This spares patients from therapy-related toxicities that provide no clinical benefit. However, due to a lack of studies, it is currently unclear whether the advantages of PET-CT also translate into a measurable improvement in patient survival. A retrospective analysis assessed the survival data of 145 patients with esophageal carcinoma stages I (eight patients; 5%), II (45; 31%), III (79; 55%), IV (8; 5%) and unknown (5; 4%). Patients were treated between 1999 and 2014 either with primary chemoradiation (n = 101) or neoadjuvant chemoradiation at the Department of Radiation Oncology, University Medical Center Mainz, followed by transabdominal or transthoracic tumor resection (n = 44). Of the 145 patients, 64 (44%) had undergone PET-CT. Univariate analysis showed the use of PET-CT to be associated with significantly longer local recurrence-free survival (p = 0.006) and tended to translate into a measurable improvement of overall survival (p = 0.071). Since more patients underwent surgery in the group planned using PET-CT (20% vs. 44%; p = 0.002), we carried out a multivariate Cox regression analysis to adjust for this possible confounding factor. Surgery (p = 0.042; HR 0.55; 95% confidence interval: 0.31-0.98) as well as the use of PET-CT (p = 0.048; HR 0.60; 95% confidence interval: 0.36-0.99) nearly halved the risk of local recurrence. It was only in the group of patients with PET-CT that a trend towards a shorter overall survival was evident in lymph node-positive patients (p = 0.16), whereas nodal stage did not impact on survival in patients staged without PET-CT (p = 0.97). To the best of our knowledge these

  6. Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

    Science.gov (United States)

    Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko

    2015-06-01

    Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid registration into routine clinical practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  7. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  8. CT and MRI of the liver: when, what, why?; CT und MRT der Leber: wann, was, warum

    Energy Technology Data Exchange (ETDEWEB)

    Budjan, J.; Schoenberg, S.O.; Attenberger, U.I. [Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Mannheim (Germany)

    2017-05-15

    The detection and differential diagnostic clarification of liver pathologies play an important role in almost all medical disciplines. Because of its superior soft tissue contrast, the availability of liver-specific contrast agents and functional techniques, magnetic resonance imaging (MRI) is the method of choice for the diagnostics of focal and diffuse liver pathologies. In addition to its superior detection and differentiation capabilities, MRI can provide prognostic information and enable early assessment of the therapy response for malignant liver lesions using functional techniques, especially diffusion imaging. Computed tomography (CT) is the imaging method of choice for the detection of traumatic liver injury. Despite the increasing availability of functional techniques in CT, MRI remains the overall modality of choice in liver imaging. (orig.) [German] Die Detektion und die differenzialdiagnostische Abklaerung von Leberpathologien spielen in nahezu allen medizinischen Disziplinen eine bedeutende Rolle. Ihre Vorteile in Hinblick auf Weichteilkontrast, die Verfuegbarkeit leberspezifischer Kontrastmittel und funktionelle Techniken machen die MRT zum bildgebenden Verfahren der Wahl fuer die gezielte Abklaerung fokaler oder diffuser Leberpathologien. Neben hoeheren Detektionsraten und besseren Differenzierungsmoeglichkeiten stehen in der MRT funktionelle Techniken - insbesondere die Diffusionsbildgebung - zur Verfuegung, die eine Prognoseabschaetzung und die fruehe Beurteilung von Therapieansprechen bei malignen Leberlaesionen erlauben. Die CT ist bei der Detektion traumatischer Leberverletzungen Bildgebungsverfahren der Wahl; trotz der auch in der CT zunehmend verfuegbaren funktionellen Techniken bleibt die MRT in der Leberbildgebung weiterhin ueberlegen. (orig.)

  9. Neuroendocrine tumors of the abdomen; Neuroendokrine Tumoren des Abdomens

    Energy Technology Data Exchange (ETDEWEB)

    Juchems, M. [Klinikum Konstanz, Diagnostische und Interventionelle Radiologie, Konstanz (Germany)

    2018-01-15

    Gastroenteropancreatic neuroendocrine neoplasia (GEP-NEN) are a heterogeneous group of complex tumors, which is often difficult to classify due to heterogeneity and varying locations. Ultrasound, computed tomography (CT), magnetic resonance imaging (MRI) and positron-emission tomography computed tomography (PET/CT) are available for the localization of NEN as well as for the staging. In particular, nuclear medical examination methods with somatostatin analogues are of great importance since radioactively labeled receptor ligands make tumors visible with high sensitivity. CT and MRT have high detection rates for GEP-NEN and have been further improved by developments such as diffusion weighted imaging. The nuclear medical methods, however, are superior in detection, especially in gastrointestinal NEN It is important for the radiologist to become acquainted with the NEN as they can occur ubiquitously in the abdomen and should be identified as such. Since GEP-NEN are predominantly hypervascularized, a biphasic examination technique is obligatory for contrast-enhanced cross-sectional imaging. PET/CT with somatostatin analogs should be used for further diagnosis. (orig.) [German] Gastroenteropankreatische neuroendokrine Neoplasien (GEP-NEN) sind eine heterogene Gruppe komplexer Tumoren, deren Einteilung aufgrund der Heterogenitaet und unterschiedlichen Lokalisation haeufig schwerfaellt. Fuer die Lokalisation der NEN sowie zur Ausbreitungsdiagnostik und Metastasensuche stehen Ultraschalldiagnostik, Computertomographie (CT), Magnetresonanztomographie (MRT) und die Positronenemissionstomographie-Computertomographie (PET-CT) zur Verfuegung. Insbesondere nuklearmedizinische Untersuchungsmethoden mit Somatostatinanaloga sind von hoher Wertigkeit, da sie ueber radioaktiv markierte Rezeptoliganden Tumoren mit hoher Sensitivitaet sichtbar machen. CT und MRT haben hohe Detektionsraten bei den GEP-NEN und konnten durch Weiterentwicklungen, wie Diffusionsbildgebung, weiter

  10. Granular Cell Tumor of the Neurohypophysis: A Case Report with Magnetic Resonance and CT Imaging Findings

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Ka Yeon; Lee, Sun Jin; Ahn, Kook Jin; Jung, So Lyung; Kim, Bum Soo [Dept. of Radiology, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Lee, Yeon Soo [Dept. of Pathology, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Jeun, Shin Soo [Dept. of Neurosurgery, Seoul St.Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    A granular cell tumor (GCT) usually occurs as a small, solitary, nodular tumor and is more prevalent in adult females. The authors report the magnetic resonance (MR) and CT imaging findings in a 61-year-old woman with GCT of the neurohypophysis presenting with a history of reduced visual acuity in her right eye. MR images showed a suprasellar mass with an isointense signal on a T1-weighted image and an hypointense signal on a T2-weighted image. The histopathological examination revealed a granular cell tumor. In this article, the MR and CT imaging findings of GCT of the neurohypophysis with the literature reviews are discussed.

  11. Granular Cell Tumor of the Neurohypophysis: A Case Report with Magnetic Resonance and CT Imaging Findings

    International Nuclear Information System (INIS)

    Choo, Ka Yeon; Lee, Sun Jin; Ahn, Kook Jin; Jung, So Lyung; Kim, Bum Soo; Lee, Yeon Soo; Jeun, Shin Soo

    2011-01-01

    A granular cell tumor (GCT) usually occurs as a small, solitary, nodular tumor and is more prevalent in adult females. The authors report the magnetic resonance (MR) and CT imaging findings in a 61-year-old woman with GCT of the neurohypophysis presenting with a history of reduced visual acuity in her right eye. MR images showed a suprasellar mass with an isointense signal on a T1-weighted image and an hypointense signal on a T2-weighted image. The histopathological examination revealed a granular cell tumor. In this article, the MR and CT imaging findings of GCT of the neurohypophysis with the literature reviews are discussed.

  12. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Li Chao; Lv Haibo

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3–127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2–53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7–124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2–62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14–47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice. (author)

  13. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model.

    Science.gov (United States)

    Sun, Chang-Jin; Li, Chao; Lv, Hai-Bo; Zhao, Cong; Yu, Jin-Ming; Wang, Guang-Hui; Luo, Yun-Xiu; Li, Yan; Xiao, Mingyong; Yin, Jun; Lang, Jin-Yi

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3-127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2-53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7-124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2-62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14-47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice.

  14. Tumors of the sellar region; Tumoren der Sellaregion

    Energy Technology Data Exchange (ETDEWEB)

    Lieb, J.M. [Imamed Radiologie Nordwest, Basel (Switzerland); Ahlhelm, F.J. [Kantonsspital Baden, Abteilung fuer Neuroradiologie, Baden (Switzerland)

    2017-09-15

    The anatomy of the sellar region is complex and tumors of the sellar region are very variable because they arise from the many different tissue types in the sellar region, ranging from benign to life-threatening. Despite this variety, approximately 80% of sellar region tumors are due to the 5 most common lesions: adenomas, meningiomas, aneurysms, astrocytomas and craniopharyngiomas. In addition to clinical and laboratory results, the magnetic resonance imaging (MRI) and computed tomography (CT) results including the exact anatomical position and the proliferation pattern of the lesion are decisive for the diagnosis. The gold standard for diagnostic imaging is multiplanar, thin section, contrast-enhanced MRI with soft tissue contrast. Vessel imaging and CT are complementary modalities in selected cases and often for preoperative planning. Whereas most sellar region tumors can be well visualized with multiplanar, contrast-enhanced MRI, for very small intrapituitary microadenomas dynamic contrast-enhanced T1-weighted sequences can be necessary. Microadenomas can often only be clearly demarcated from the rest of the pituitary tissue due to the different perfusion pattern. Optimized diffusion-weighted images can also be useful for narrowing down the differential diagnoses of sellar region tumors. Tumors of the sellar region can be subdivided in intrahypophysial and extrahypophysial lesions as well as intrinsic skull base lesions. The most common sellar tumors are adenomas of the pituitary gland, which can be subdivided into microadenoma and macroadenoma and into secretory and non-secretory. If there is suspicion of a sellar region lesion due to clinical or laboratory results, multiplanar contrast enhanced thin section MRI of the sellar region should be used as the primary imaging modality. The keys to the diagnosis are the precise anatomical location of the lesion and the proliferation pattern. The most common lesions in the sellar region are pituitary gland adenomas

  15. DELAYED FDG-PET/CT IMAGES IN PATIENTS WITH BRAIN TUMORS - IMPACT ON VISUAL AND SEMIQUANTITATIVE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Pavel H. Bochev

    2013-01-01

    Full Text Available Background: Despite the extensive use of FDG-PET/CT its role in brain tumor assessment remains controversial mostly because of the physiologically high brain uptake which easily obscures pathological processes. The wide availability of FDG, however, maintains the interest in FDG neuro-oncological applications. Objective: to evaluate the use of a late registration at 180min in patients with brain tumors, studied with FDG-PET/CT based on visual and semiquantitative analysis. Materials and methods: 38 patients with brain neoplasms and non-tumor structural lesions underwent a selective brain 18F-FDG PET/CT at two time points at 60 and 180 minutes after administration. Visual assessment was made by two readers with interobserver agreement calculation. Region ratio comparison with three different reference regions - the contralateral one, the white matter, and the cerebellum was used as a base for semiquantitative analysis. Results: Visual analysis showed better delineation of malignant lesion on late registrations with higher inter/intraobserver agreement as compared to the early images. Semiquantitative analysis demonstrated significant differences in early and late indices of metastases and gliomas, but failed in distinguishing gliomas from metastatic lesions and benign lesions.Conclusion: Delayed brain images with FDG-PET/CT at 180 min after injection provide better tumor delineation, higher accuracy, lower interobserver variations. The use of semiquantitative indices, irrespective of the reference region used, is of limited value

  16. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  17. New radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagishita, A.; Shiga, I.; Kanzaki, H. (Keio Univ., Tokyo (Japan). School of Medicine)

    1982-07-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors.

  18. New radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yagishita, A; Shiga, I; Kanzaki, H [Keio Univ., Tokyo (Japan). School of Medicine

    1982-07-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors.

  19. C-arm guided closed reduction of zygomatic arch fracture

    International Nuclear Information System (INIS)

    Eo, Yoon Ki; Lee, Dong Kun; Kim, Jeong Sam; Jang, Young Il

    1999-01-01

    The zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Alling and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients

  20. Using {sup 18F} FDG PET/CT to Detect an occult Mesenchymal Tumor Causing Oncogenic Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Yong Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Oncogenic osteomalacia is a rare paraneoplastic syndrome characterized by renal phosphate excretion, hypophosphatemia, and osteomalacia. This syndrome is often caused by tumors of mesenchymal origin. Patients with oncogenic osteomalacia have abnormal bone mineralization, resulting in a high frequency of fractures. Tumor resection is the treatment of choice, as it will often correct the metabolic imbalance. Although oncogenic osteomalacia is a potentially curable disease, diagnosis is difficult and often delayed because of the small size and sporadic location of the tumor. Bone scintigraphy and radiography best characterize osteoma lacia; magnetic resonance imaging findings are nonspecific. Here, we report a case of oncogenic osteomalacia secondary to a phosphaturic mesenchymal tumor that was successfully detected by {sup 18F} fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18F} FDG PET/CT). This case illustrates the advantages of {sup 18F} FDG PET/CT in detecting the occult mesenchymal tumor that causes oncogenic osteomalacia.

  1. Therapeutic response assessment using 3D ultrasound for hepatic metastasis from colorectal cancer: Application of a personalized, 3D-printed tumor model using CT images.

    Directory of Open Access Journals (Sweden)

    Ye Ra Choi

    Full Text Available To evaluate accuracy and reliability of three-dimensional ultrasound (3D US for response evaluation of hepatic metastasis from colorectal cancer (CRC using a personalized 3D-printed tumor model.Twenty patients with liver metastasis from CRC who underwent baseline and after chemotherapy CT, were retrospectively included. Personalized 3D-printed tumor models using CT were fabricated. Two radiologists measured volume of each 3D printing model using 3D US. With CT as a reference, we compared difference between CT and US tumor volume. The response evaluation was based on Response Evaluation Criteria in Solid Tumors (RECIST criteria.3D US tumor volume showed no significant difference from CT volume (7.18 ± 5.44 mL, 8.31 ± 6.32 mL vs 7.42 ± 5.76 mL in CT, p>0.05. 3D US provided a high correlation coefficient with CT (r = 0.953, r = 0.97 as well as a high inter-observer intraclass correlation (0.978; 0.958-0.988. Regarding response, 3D US was in agreement with CT in 17 and 18 out of 20 patients for observer 1 and 2 with excellent agreement (κ = 0.961.3D US tumor volume using a personalized 3D-printed model is an accurate and reliable method for the response evaluation in comparison with CT tumor volume.

  2. Shallow and deep breath lung tumor volume as estimated by spiral volumetric CT in comparison to standard axial CT using virtual simulation

    International Nuclear Information System (INIS)

    Quader, M.A.; Kalend, A.M.; Deutsch, M.; Greenberger, J.S.

    1995-01-01

    Purpose/Objective: In order to assess an individual patient tumor volume (TV) margins that are sufficient to design a beam-eye-view (BEW) conformal portal, the radiographic extent of gross tumor volume (GTV) dimensions and its fluctuation with breathing are measured by fast spiral CT scanning of patients treated for Stage II, III lung cancers using 5-6 field multi-collimated conformal beams. Materials and Methods: Over the course of conformal radiotherapy for lung cancer, a full thorax CT scans of the patient were taken by conventional axial CT scanning with patients immobilized in the treatment position and breathing normally. Patient(s) with good pulmonary function test (PFT) status were selected to perform deep breathing and re-scanned by fast spiral techniques in order to re-acquire the tomographic variation in the (GTV) with breathing. A Picker spiral ZAP-100 software running on the AQSim-PQ-2000 was used with a variable helical pitch of 1.0, 1.5 and 2.0. The variable pitch spirals were limited to tumor bed, diaphragm and lung apex area for measurements. Effect of breathing motion along x,y,z direction were then assessed for each beam-eye-view portal as seen in digitally reconstructed radiography (DRR) at the treated gantry angle. Results: Comparison of axial and spiral scans shows the progression of lung and diaphram motion with breathing can be gauged better in spiral scans. The movement of the diaphragm during shallow breathing has been found to be 2-3cm by measuring the distance between the most inferior and superior slices where diaphragm is present. The variation of the tumor dimensions along AP/PA and lateral direction seems to be less sensitive to breathing than those along inferior-superior direction. Conclusion: The fast spiral CT scanning is sensitive to patient lung motion and can be used to determine the fluctuations of the gross tumor volume with breathing. The extent of the fluctuation is location dependent and increases as one moves from the

  3. Receptor PET/CT for determining the somatostatin receptor status of neuroendocrine tumors before and after peptide receptor radionuclide therapy (PRRT): Clinical experience after 1,500 studies

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.; Leonhardi, J.; Kroeger, R.; Wortmann, R.; Mueller, D.

    2007-01-01

    Full text: The octapeptide [DOTA]-1-Nal3-octreotide (DOTA-NOC) has 3 to 4 times higher binding affinity to sstr2 than DOTATOC (Wild 2003). We labeled this peptide with the Ga-68 (t1/2 68 min) and used it in pts with metastatic NET before/after PRRT for evaluating the sstr status by semiquantitative PET/CT imaging. Methods: Ga-68 was eluted from a Ge-68/Ga-68 generator using 0.1 M HCl. Following purifications, Ga-68 was eluted into a labeling vial containing 0.05 mg DOTA-NOC. Radiolabeling yields of >80% were achieved within 15 min at >95C. After purification (C18 cartridge) and a final elution, 370-700 MBq of Ga-68 DOTA-NOC were obtained with 100% radiochemical purity within 20 min (about 70% yield). Results: 1,500 PET/CT studies were performed in pts with histologically proven NET and progressive metastases before and after PRRT. Acquisition was started 20-270 min after injection of a mean of 100 MBq (46-260 MBq) Ga-68 DOTA-NOC using an LSO-based PET/CT (biograph DUO, Siemens). SUV were determined for all tumor lesions and normal tissues. SUV in metastases was as high as 152 whereas normal tissue was in the range of 0.4 (lung) to 33 (spleen). Outstanding PET/CT images of all known tumor lesions and in addition very small lymph node and bone metastases (<5 mm) were easily visualized as early as 20 min p.i. Clearly more lesions were detected as compared to Tc-99m EDDA-HYNIC-TOC or In-111 DOTA-NOC SPECT or as seen on CT or MRI images (especially regarding lymph node metastases, bone lesions and unknown primaries). Conclusions: Molecular receptor PET/CT imaging using the Ga-68-labeled somatostatin analogue DOTA-NOC detects neuroendocrine tumor metastases with very high diagnostic sensitivity and specificity. Semiquantitative uptake measurements (SUV) allow predicting the tumor uptake of Y-90 or Lu-177- labeled peptides before PRRT and are highly useful for therapy control to determine the 'molecular tumor response' which can precede the morphologic responses by months

  4. Peritumoral brain edema in intracranial tumor evaluated by CT perfusion imaging

    International Nuclear Information System (INIS)

    Shi Yuxin; Xu Jianfeng

    2005-01-01

    Objective: To semi-quantitatively evaluate the cerebral perfusion in the peritumoral brain edema of cerebral tumors using CT perfusion imaging. Methods: Twenty-one patients with peritumoral brain edema (including pathologically confirmed meningiomas n=4, metastasis n=10, gliomas n=7) were examined by CT perfusion imaging. The regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), and mean transit time (MTT) were calculated for peritumoral brain edema and the contralateralwhite matter. The rCBF and rCBV were compared between peritumoral brain edema and the contralateral white matter. The mean ratios (edema/contralateral white matter) of rCBF and rCBV were compared among the three tumors. Results: The rCBF and rCBV of peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis (rCBF: t=2.92 and 3.82, P 0.05). The mean ratios (edema/contralateralwhite matter) of rCBF and rCBV were not significantly different between meningiomas and metastasis (t=0.23 and 0.73, P>0.05), but both of them were significantly lower than those of gliomas (t=3.05 and 3.37, P<0.01, 0.005). Conclusion: The rCBF and rCBV in peritumoral brain edema were significantly lower than those of contralateral white matter in patients with meningiomas and metastasis, while almost the same with or higher than those of contralateral white matter in patients with gliomas. CT perfusion can provide quantitative information of blood flow in peritumoral brain edema, and is useful in the diagnosis and follow-up of cerebral tumors. (authors)

  5. Stereotactic interstitial brachytherapy for the treatment of oligodendroglial brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    El Majdoub, Faycal; Neudorfer, Clemens; Maarouf, Mohammad [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); University of Witten/Herdecke, Department of Stereotaxy and Functional Neurosurgery, Center of Neurosurgery, Cologne-Merheim Medical Center (CMMC), Cologne (Germany); Blau, Tobias; Deckert, Martina [University Hospital of Cologne, Department of Neuropathology, Cologne (Germany); Hellmich, Martin [University Hospital of Cologne, Institute of Statistics, Informatics and Epidemiology, Cologne (Germany); Buehrle, Christian [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); Sturm, Volker [University Hospital of Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); University Hospital of Wurzburg, Department of Neurosurgery, Wuerzburg (Germany)

    2015-12-15

    We evaluated the treatment of oligodendroglial brain tumors with interstitial brachytherapy (IBT) using {sup 125}iodine seeds ({sup 125}I) and analyzed prognostic factors. Between January 1991 and December 2010, 63 patients (median age 43.3 years, range 20.8-63.4 years) suffering from oligodendroglial brain tumors were treated with {sup 125}I IBT either as primary, adjuvantly after incomplete resection, or as salvage therapy after tumor recurrence. Possible prognostic factors influencing disease progression and survival were retrospectively investigated. The actuarial 2-, 5-, and 10-year overall and progression-free survival rates after IBT for WHO II tumors were 96.9, 96.9, 89.8 % and 96.9, 93.8, 47.3 %; for WHO III tumors 90.3, 77, 54.9 % and 80.6, 58.4, 45.9 %, respectively. Magnetic resonance imaging demonstrated complete remission in 2 patients, partial remission in 13 patients, stable disease in 17 patients and tumor progression in 31 patients. Median time to progression for WHO II tumors was 87.6 months and for WHO III tumors 27.8 months. Neurological status improved in 10 patients and remained stable in 20 patients, while 9 patients deteriorated. There was no treatment-related mortality. Treatment-related morbidity was transient in 11 patients. WHO II, KPS ≥ 90 %, frontal location, and tumor surface dose > 50 Gy were associated with increased overall survival (p ≤ 0.05). Oligodendroglioma and frontal location were associated with a prolonged progression-free survival (p ≤ 0.05). Our study indicates that IBT achieves local control rates comparable to surgery and radio-/chemotherapy treatment, is minimally invasive, and safe. Due to the low rate of side effects, IBT may represent an attractive option as part of a multimodal treatment schedule, being supplementary to microsurgery or as a salvage therapy after chemotherapy and conventional irradiation. (orig.) [German] Die Behandlung oligodendroglialer Hirntumoren durch die interstitielle Brachytherapie

  6. A fundamental study of dynamic CT for hemodynamics in experimental hepatic tumors

    International Nuclear Information System (INIS)

    Yamakawa, Fumiko

    1991-01-01

    Dynamic CT was performed using iodamide meglumine (2 ml/kg) to investigate hemodynamics in experimental hepatic tumors, tumor margins and in normal hepatic tissue as well in rabbits with VX 2 -induced hepatic tumors. Peak time (PT) and first moment (M1) were calculated from a time density curve prepared by eight consecutive 3-second scans over a period of 55 seconds. PT and M1 in tumors were significantly shorter than those in tumor margins and normal tissue, but were not influenced by tumor size. PT and M1 in tumor margins and normal tissue became longer with enlargement of the tumor. Ligation of the hepatic artery caused (1) no change in PT or M1 in normal tissue and tumor margins and (2) difficulty in measuring PT and M1 in tumors. Ligation of the portal vein caused (1) difficulty in measuring PT and M1 in normal tissue and tumor margins and (2) no change in PT or M1 in tumors. Pathological studies of specimens taken from each region of interest (ROI) showed that hemodynamics in the tumors reflected tumor-specific vascular structures. (author)

  7. MRI and CT findings of the giant cell tumors of the skull; five cases and a review of the literature

    International Nuclear Information System (INIS)

    Kashiwagi, Nobuo; Hirabuki, Norio; Andou, Kumiko; Yoshifumi, Narumi; Tanaka, Hisashi; Morino, Hideo; Taki, Takuyu; Ishikura, Reiichi; Hirota, Seiichi; Onishi, Hiromitu; Nakamura, Hironobu

    2006-01-01

    Purpose: To investigate CT and MR findings of giant cell tumors (GCTs) of the skull, an unusual site for such tumors. Materials and methods: CT and MR features of five histologically proven giant cell tumors of the skull were retrospectively reviewed. We also reviewed 22 cases in the literature that included MR or CT findings. Results: Three of the tumors originated from the temporal bone with predominantly medial extension, and the other two were centered in the body of the sphenoid bone and featured symmetrical soft tissue extension. CT images with bone window settings showed reactive bone changes for all three tumors of the temporal bone, suggesting slow growth for example, an expanded intradiploic space, expansive remodelling and development of foci of pressure erosion. GCTs of the sphenoid bone showed purely osteolytic changes without remodelling. Although the MR signals and enhancement patterns varied, all the tumors of the temporal bone had a markedly low intensity area on T2-weighted images, which was not seen in the tumors of the sphenoid bone. The findings for our cases generally corresponded to those reported in the literature. Conclusion: Giant cell tumors of the skull have two preferential sites and may have characteristic tendencies as to their extent. Bone changes and MR signals appear to show differences between the two sites

  8. The Serum CA-125 Concentration Data Assists in Evaluating CT Imaging Information When Used to Differentiate Borderline Ovarian Tumor from Malignant Epithelial Ovarian Tumors

    International Nuclear Information System (INIS)

    Shin, Ji Eun; Choi, Hyuck Jae; Kim, Mi Hyun; Cho, Kyoung Sik

    2011-01-01

    We wanted to evaluate the diagnostic value of serum CA-125 concentration, when used in combination with the preoperative contrast-enhanced CT results, to differentiate borderline ovarian tumors (BOTs) from stage I malignant epithelial ovarian tumors (MEOTs). Ninety-eight masses (46 BOTs and 52 stage I MEOTs) from 87 consecutive patients (49 with BOTs and 38 with stage I MEOTs) who had undergone preoperative contrast-enhanced computed tomography (CT) and surgical staging were evaluated retrospectively and independently by two radiologists. The preoperative serum CA-125 concentration was measured in all patients. The utility of analyzing serum CA-125 concentration in combination with the CT results was evaluated by receiver operating characteristic (ROC) curve analysis. An irregular tumor surface and lymphadenopathy were predictive of a MEOT. ROC analysis showed that the combination of CT data and the serum CA-125 level resulted in a higher diagnostic performance than did using the CT alone for differentiating BOTs from MEOTs. The areas under the curves (AUCs) without and with the use of the serum CA-125 level data were 0.67 (95% confidence interval [CI]: 0.57-0.77) and 0.78 (95% CI: 0.68-0.85), respectively, for reader 1 (p = 0.029) and 0.71 (95% CI: 0.61-0.80) and 0.81 (95% CI: 0.72-0.89), respectively, for reader 2 (p = 0.009). The serum CA-125 concentration is of additional diagnostic value when used in conjunction with the CT imaging results for differentiating BOTs from MEOTs.

  9. A comparison of 111In- or 64Cu-DOTA-trastuzumab Fab fragments for imaging subcutaneous HER2-positive tumor xenografts in athymic mice using microSPECT/CT or microPET/CT

    Science.gov (United States)

    2011-01-01

    Background Our objective was to compare 111In- or 64Cu-DOTA-trastuzumab Fab fragments for imaging small or large s.c. tumor xenografts in athymic mice that display a wide range of human epidermal growth factor receptor-2 (HER2) expression using microSPECT/CT or microPET/CT. Methods Trastuzumab Fab were labeled with 111In or 64Cu by conjugation to 1,4,7,10-tetraazacyclododecane N, N', N'', N'''-tetraacetic acid (DOTA). The purity of 111In- and 64Cu-DOTA-trastuzumab Fab was measured by SDS-PAGE and HPLC. HER2 binding affinity was determined in saturation radioligand binding assays using SKBR-3 cells (1.3 × 106 HER2/cell). MicroSPECT/CT and microPET/CT were performed in athymic mice bearing s.c. BT-20 and MDA-MB-231 xenografts with low (0.5 to 1.6 × 105 receptors/cell), MDA-MB-361 tumors with intermediate (5.1 × 105 receptors/cell) or SKOV-3 xenografts with high HER2 expression (1.2 × 106 receptors/cell) at 24 h p.i. of 70 MBq (10 μg) of 111In-DOTA-trastuzumab Fab or 22 MBq (10 μg) of 64Cu-DOTA-trastuzumab Fab or irrelevant 111In- or 64Cu-DOTA-rituximab Fab. Tumor and normal tissue uptake were quantified in biodistribution studies. Results 111In- and 64Cu-DOTA-trastuzumab were > 98% radiochemically pure and bound HER2 with high affinity (Kd = 20.4 ± 2.5 nM and 40.8 ± 3.5 nM, respectively). MDA-MB-361 and SKOV-3 tumors were most clearly imaged using 111In- and 64Cu-DOTA-trastuzumab Fab. Significantly higher tumor/blood (T/B) ratios were found for 111In-DOTA-trastuzumab Fab than 111In-DOTA-rituximab Fab for BT-20, MDA-MB-231 and MDA-MB-361 xenografts, and there was a direct association between T/B ratios and HER2 expression. In contrast, tumor uptake of 64Cu-DOTA-trastuzumab Fab was significantly higher than 64Cu-DOTA-rituximab Fab in MDA-MB-361 tumors but no direct association with HER2 expression was found. Both 111In- and 64Cu-DOTA-trastuzumab Fab imaged small (5 to 10 mm) or larger (10 to 15 mm) MDA-MB-361 tumors. Higher blood, liver, and spleen

  10. Precise Point Positioning with the BeiDou Navigation Satellite System

    Directory of Open Access Journals (Sweden)

    Min Li

    2014-01-01

    Full Text Available By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS around the World. The Position and Navigation Data Analyst (PANDA software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP. The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems.

  11. Precise point positioning with the BeiDou navigation satellite system.

    Science.gov (United States)

    Li, Min; Qu, Lizhong; Zhao, Qile; Guo, Jing; Su, Xing; Li, Xiaotao

    2014-01-08

    By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS) around the World. The Position and Navigation Data Analyst (PANDA) software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP). The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems.

  12. Does the pretreatment tumor sampling location correspond with metabolic activity on 18F-FDG PET/CT in breast cancer patients scheduled for neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B., E-mail: b.koolen@nki.nl [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Elshof, Lotte E. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vogel, Wouter V. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Valdés Olmos, Renato A. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Purpose: To define the correlation between the core biopsy location and the area with highest metabolic activity on 18F-FDG PET/CT in stage II–III breast cancer patients before neoadjuvant chemotherapy. Also, we would like to select a subgroup of patients in which PET/CT information may optimize tumor sampling. Methods: A PET/CT in prone position was acquired in 199 patients with 203 tumors. The distance and relative difference in standardized uptake value (SUV) between core biopsy localization (indicated by a marker) and area with highest degree of FDG uptake were evaluated. A distance ≥2 cm and a relative difference in SUV ≥25% were considered clinically relevant and a combination of both was defined as non-correspondence. Non-correspondence for different tumor characteristics (TNM stage, lesion morphology on MRI and PET/CT, histology, subtype, grade, and Ki-67) was assessed. Results: Non-correspondence was found in 28 (14%) of 203 tumors. Non-correspondence was significantly associated with T-stage, lesion morphology on MRI and PET/CT, tumor diameter, and histologic type. It was more often seen in tumors with a higher T-stage (p = 0.028), diffuse (non-mass) and multifocal tumors on MRI (p = 0.001), diffuse and multifocal tumors on PET/CT (p < 0.001), tumors >3 cm (p < 0.001), and lobular carcinomas (p < 0.001). No association was found with other features. Conclusion: Non-correspondence between the core biopsy location and area with highest FDG uptake is regularly seen in stage II–III breast cancer patients. PET/CT information and possibly FDG-guided biopsies are most likely to improve pretreatment tumor sampling in tumors >3 cm, lobular carcinomas, and diffuse and multifocal tumors.

  13. [A Retrospective Study of Mean Computed Tomography Value to Predict 
the Tumor Invasiveness in AAH and Clinical Stage Ia Lung Cancer].

    Science.gov (United States)

    Wu, Hanran; Liu, Changqing; Xu, Meiqing; Xiong, Ran; Xu, Guangwen; Li, Caiwei; Xie, Mingran

    2018-03-20

    Recently, the detectable rate of ground-glass opacity (GGO ) was significantly increased, a appropriate diagnosis before clinic treatment tends to be important for patients with GGO lesions. The aim of this study is to validate the ability of the mean computed tomography (m-CT) value to predict tumor invasiveness, and compared with other measurements such as Max CT value, GGO size, solid size of GGO and C/T ratio (consolid/tumor ratio, C/T) to find out the best measurement to predict tumor invasiveness. A retrospective study was conducted of 129 patients who recieved lobectomy and were pathological confirmed as atypical adenomatous pyperplasia (AAH) or clinical stage Ia lung cance in our center between January 2012 and December 2013. Of those 129 patients, the number of patients of AAH, AIS, AIS and invasive adenocarcinoma were 43, 26, 17 and 43, respectively. We defined AAH and AIS as noninvasive cancer (NC), MIA and invasive adenocarcinoma were categorized as invasive cancer(IC). We used receiver operating characteristic (ROC) curve analysis to compare the ability to predict tumor invasiveness between m-CT value, consolidation/tumor ratio, tumor size and solid size of tumor. Multiple logistic regression analyses were performed to determine the independent variables for prediction of pathologic more invasive lung cancer. 129 patients were enrolled in our study (59 male and 70 female), the patients were a median age of (62.0±8.6) years (range, 44 to 82 years). The two groups were similar in terms of age, sex, differentiation (P>0.05). ROC curve analysis was performed to determine the appropriate cutoff value and area under the cure (AUC). The cutoff value of solid tumor size, tumor size, C/T ratio, m-CT value and Max CT value were 9.4 mm, 15.3 mm, 47.5%, -469.0 HU and -35.0 HU, respectively. The AUC of those variate were 0.89, 0.79, 0.82, 0.90, 0.85, respectively. When compared the clinical and radiologic data between two groups, we found the IC group was strongly

  14. Measurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy.

    Science.gov (United States)

    Sung, K H; Min, E; Chung, C Y; Jo, B C; Park, M S; Lee, K

    2016-03-01

    This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy. © The Author(s) 2015.

  15. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  16. Tumoral calcium pyrophosphate dihydrate deposition disease with bone destruction in the shoulder. CT an MR findings in two cases

    International Nuclear Information System (INIS)

    Mizutani, H.; Ohba, S.; Sasaki, S.; Ando, K.; Mizutani, M.; Matsushita, Y.; Ohtsuka, T.; Terazawa, T.; Ijima, S.

    1998-01-01

    We report on specific CT and MR features in two cases of tumoral calcium pyrophosphate dihydrate deposition disease in the shoulder with unusually large tumors. CT revealed features that were specific to the disease. MR was useful for detecting the extent of the mass and for obtaining information on adjacent soft-tissue and bone-marrow changes. (orig.)

  17. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  18. Correlation between spiral CT features of pericolic infiltration and tumor angiogenesis in colorectal carcinoma

    International Nuclear Information System (INIS)

    Zhang Ruiping; Li Jianding

    2007-01-01

    Objective: To investigate the correlation of spiral CT (SCT) features with pathology, microvessel density (MVD), expression of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2( MMP-2) in colorectal carcinoma. Methods: Forty patients with colorectal carcinoma confirmed by operation were examined by SCT. The resected tumor specimens were immunohistochemically stained for the expression of VEGF, MMP-2 and the calculation of MVD. Results: The accuracy of SCT in depicting the pericolic and wall infiltration was 92.5%. The metastasis rates of colorectal cancer with pericolic infiltration and wall infiltration were 75.0% and 33.3%, respectively, the differences were statistically significant between the two groups (P<0.05). The differences of CT enhancement value, MVD, expressions of VEGF and MMP-2 between the two groups were statistically significant (P<0.05). The enhancement degree of CT had a positive correlation with MVD (P<0.05). Conclusion: SCT is accurate for depicting pericolic and wall infiltration, pericolic infiltration in colorectal carcinoma indicates the tendency of metastasis. The enhancement degree of CT might be used to quantitatively evaluate the tumor angiogenesis, expressions of VEGF and MMP-2 and MVD are closely correlated with the infiltration of colorectal cancer. (authors)

  19. CT and MRT in mediastinal and hilar masses. CT und MRT bei mediastinalen und hilaeren Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Kramer, J.; Stiglbauer, R.; Wimberger, D.; Imhof, H. (Vienna Univ. (Austria). Klinik fuer Radiodiagnostik Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Metz, V. (Vienna Univ. (Austria). 2. Chirurgische Klinik)

    1990-11-01

    Thirty-eight patients with mediastinal and/or hilar masses were imaged by computed tomography (CT) and magnetic resonance imaging (MRI). Results were analyzed retrospectively regarding the ability to demonstrate the masses, their number, size, definition, location and tissue characteristics. CT and MRI showed equivalent results in 32 cases; additional information was obtained in two patients by CT, in four patients by MRI. In view of the specific advantages and limitations of both CT and MRI we believed that in patients with mediastinal and/or hilar masses, contrast enhanced CT remains the procedure of choice after performing plain chest radiographs; in certain cases MRI will prove useful for further evaluation. (orig.).

  20. Mehrfacheffekt-Feuchtluftdestillation bei Umgebungsdruck

    OpenAIRE

    Müller-Holst, Hendrik

    2007-01-01

    Ein neuartiges Verfahren zur Feuchtluftdestillation mittels Verdunstung und Kondensation in einer einzigen Kammer wurde im Rahmen der Arbeit umfassend analysiert. Das Verfahren arbeitet bei Umgebungsdruck; der dadurch bei Temperaturen unter dem Siedepunkt verringerte Stoffübergang wird durch große Austauschflächen mit hoher Packungsdichte kompensiert. Der Transport der im Verdunster beladenen Feuchtluft zum Kondensator erfolgt innerhalb einer optimierten geometrischen Anordnung der Baueinheit...

  1. The correlation between the rise of the tumor temperature during the hyperthermia treatment and the tumor blood flow measured by dynamic CT and 15O gas-positron emission tomography

    International Nuclear Information System (INIS)

    Hattori, Hideyuki

    1993-01-01

    This study was designed to determine the correlation between the rise of tumor temperature during hyperthermia treatment and the blood flow of the tumors measured by dynamic CT (DCT) and 15 O gas-positron emission tomography. In this report, we observed 20 patients with malignant tumors which underwent hyperthermia treatment. In each case, the temperature of the tumor was monitored with a photofiber sensor. DCT's and 15 O gas-positron emission tomographies were applied before the hyperthermia treatment. During the DCT, the tumor blood flow of each tumor was estimated by analyzing the time-dependent activity curve after a bolus injection. During the 15 O gas-positron emission tomography, the tumor blood flow was estimated by the C 15 O 2 -steady-state method. The value of the tumor blood flow estimated by DCT were proportional to those calculated by the 15 O gas-positron emission tomography. These values were inversely proportional to the rise of the temperature of the tumors during hyperthermia treatment. Our results imply that DCT as well as the 15 O gas-positron emission tomography can be used for the prediction of the tumor temperature rise during the hyperthermia treatment. (author)

  2. Accuracy of x-ray image-based 3D localization from two C-arm views: a comparison between an ideal system and a real device

    Science.gov (United States)

    Brost, Alexander; Strobel, Norbert; Yatziv, Liron; Gilson, Wesley; Meyer, Bernhard; Hornegger, Joachim; Lewin, Jonathan; Wacker, Frank

    2009-02-01

    arm X-ray imaging devices are commonly used for minimally invasive cardiovascular or other interventional procedures. Calibrated state-of-the-art systems can, however, not only be used for 2D imaging but also for three-dimensional reconstruction either using tomographic techniques or even stereotactic approaches. To evaluate the accuracy of X-ray object localization from two views, a simulation study assuming an ideal imaging geometry was carried out first. This was backed up with a phantom experiment involving a real C-arm angiography system. Both studies were based on a phantom comprising five point objects. These point objects were projected onto a flat-panel detector under different C-arm view positions. The resulting 2D positions were perturbed by adding Gaussian noise to simulate 2D point localization errors. In the next step, 3D point positions were triangulated from two views. A 3D error was computed by taking differences between the reconstructed 3D positions using the perturbed 2D positions and the initial 3D positions of the five points. This experiment was repeated for various C-arm angulations involving angular differences ranging from 15° to 165°. The smallest 3D reconstruction error was achieved, as expected, by views that were 90° degrees apart. In this case, the simulation study yielded a 3D error of 0.82 mm +/- 0.24 mm (mean +/- standard deviation) for 2D noise with a standard deviation of 1.232 mm (4 detector pixels). The experimental result for this view configuration obtained on an AXIOM Artis C-arm (Siemens AG, Healthcare Sector, Forchheim, Germany) system was 0.98 mm +/- 0.29 mm, respectively. These results show that state-of-the-art C-arm systems can localize instruments with millimeter accuracy, and that they can accomplish this almost as well as an idealized theoretical counterpart. High stereotactic localization accuracy, good patient access, and CT-like 3D imaging capabilities render state-of-the-art C-arm systems ideal devices for X

  3. SPECT/CT of lung nodules using 111In-DOTA-c(RGDfK) in a mouse lung carcinogenesis model.

    Science.gov (United States)

    Hayakawa, Takuya; Mutoh, Michihiro; Imai, Toshio; Tsuta, Koji; Yanaka, Akinori; Fujii, Hirofumi; Yoshimoto, Mitsuyoshi

    2013-08-01

    Lung cancer is one of the leading causes of cancer-related deaths worldwide, including Japan. Although computed tomography (CT) can detect small lung lesions such as those appearing as ground glass opacity, it cannot differentiate between malignant and non-malignant lesions. Previously, we have shown that single photon emission computed tomography (SPECT) imaging using (111)In-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-cyclo-(Arg-Gly-Asp-D-Phe-Lys) (DOTA-c(RGDfK)), an imaging probe of αvβ3 integrin, is useful for the early detection of pancreatic cancer in a hamster pancreatic carcinogenesis model. In this study, we aimed to assess the usefulness of SPECT/CT with (111)In-DOTA-c(RGDfK) for the evaluation of the malignancy of lung cancer. Lung tumors were induced by a single intraperitoneal injection (250 mg/kg) of urethane in male A/J mice. Twenty-six weeks after the urethane treatment, SPECT was performed an hour after injection of (111)In-DOTA-c(RGDfK). Following this, the radioactivity ratios of tumor to normal lung tissue were measured by autoradiography (ARG) in the excised lung samples. We also examined the expression of αvβ3 integrin in mouse and human lung samples. Urethane treatment induced 5 hyperplasias, 41 adenomas and 12 adenocarcinomas in the lungs of 8 A/J mice. SPECT with (111)In-DOTA-c(RGDfK) could clearly visualize lung nodules, though we failed to detect small lung nodules like adenoma and hyperplasias (adenocarcinoma: 66.7%, adenoma: 33.6%, hyperplasia: 0.0%). ARG analysis revealed significant uptake of (111)In-DOTA-c(RGDfK) in all the lesions. Moreover, tumor to normal lung tissue ratios increased along with the progression of carcinogenesis. Histopathological examination using human lung tissue samples revealed clear up-regulation of αvβ3 integrin in well-differentiated adenocarcinoma (Noguchi type B and C) rather than atypical adenomatous hyperplasia. Although there are some limitations in evaluating the malignancy of

  4. A new radiological examination for tumor in the internal auditory canal by combination of air CT cisternography and target imaging

    International Nuclear Information System (INIS)

    Yagishita, Akira; Shiga, Itsuo; Kanzaki, Hitoshi

    1982-01-01

    A 56-year-old man was admitted to the hospital because of progressive right hearing disturbance and tinnitus. An x-ray film of the skull demonstrated dilatation of the right internal auditory canal. Intravcnously enhanced CT didn't reveal any tumor in the right cerebellopontine angle. An intracanalicular tumor was demonstrated by air CT cisternography with target imaging, and confirmed by surgery. This method is useful for the radiological evaluation of the intracanalicular tumors. (author)

  5. Interactive stereotactic surgical system for the removal of intracranial tumors utilizing the CO2 laser and CT-derived database

    International Nuclear Information System (INIS)

    Kall, B.A.; Kelly, P.J.; Goerss, S.J.

    1985-01-01

    The transposition of data derived from computed tomography into three-dimensional stereotactic space has been found to be useful for the removal of intracranial tumors by a stereotactically directed CO 2 laser. Serial cross sections of a CT-derived tumor volume sliced orthogonal to any surgical trajectory are displayed in the operating room. Tumor slices are interactively vaporized with a stereotactically directed carbon dioxide laser. In this manner, the entire mass detected by CT scanning may be removed within a three-dimensionally controlled environment

  6. Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose

    Energy Technology Data Exchange (ETDEWEB)

    Venz, S. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Sander, B. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Benndorf, G. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Terstegge, K. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Podrabsky, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Cordes, M. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1994-12-31

    We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis beobachtet. Eine Neuritis der Hirnnerven war nur mit der MRT nachweisbar. Die kontrastmittelunterstuetzte MRT sollte in der bildgebenden Diagnostik einer intrakraniellen Turberkulose primaer zum Einsatz gelangen. (orig.)

  7. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  8. Can the localization of primary colonic tumors be improved by staging CT without specific bowel preparation compared to optical colonoscopy?

    International Nuclear Information System (INIS)

    Feuerlein, Sebastian; Grimm, Lars J.; Davenport, Matthew S.; Haystead, Clare M.; Miller, Chad M.; Neville, Amy M.; Jaffe, Tracy A.

    2012-01-01

    Objectives: To investigate the ability of staging computed tomography (CT) without bowel preparation to accurately localize colonic tumors compared to optical colonoscopy. Methods: The local institutional review board approved this retrospective and HIPAA-compliant study. Forty-six patients with colonic adenocarcinoma, preoperative colonoscopy, and staging CT within 60 days of resection were included. Patients underwent contrast enhanced CT imaging without bowel preparation or oral contrast. The colon was divided into four segments with the operative reports used as the standard. Rectal and cecal cancers were excluded. CT scans were reviewed by 5 readers in a segmental binary fashion using a 5-point confidence scale in two sessions blinded and unblinded to the colonoscopy report. Results: At surgery 49 tumors were found in 46 patients. Readers detected 86.1%, 74.3%, and 66.9% of lesions with 92.0%, 94.1%, and 95.4% accuracy for confidence scores of ≥3, ≥4, and 5. CT interobserver agreement was good (κ = 0.82) for the unblinded and moderate (κ = 0.60) for the blinded read. Colonoscopic localization was only 78.7% accurate with 2 tumors undiscovered. Colonoscopic accuracy was low in the descending colon (57.1%) and the transverse colon (55.6%). Conclusions: Preoperative staging CT is more accurate than colonoscopy in the localization of colonic tumors

  9. Three-dimensional CT virtual endoscopy in the detection of simulated tumors in a novel phantom bladder and ureter model.

    Science.gov (United States)

    Russell, Shane T; Kawashima, Akira; Vrtiska, Terri J; LeRoy, Andrew J; Bruesewitz, Michael R; Hartman, Robert P; Slezak, Jeffrey M; McCollough, Cynthia H; Chow, George K; King, Bernard F

    2005-03-01

    Cystoscopy and ureteroscopy have limitations in the evaluation for urothelial tumors, and both are invasive. We studied the utility of three-dimensional (3D) CT virtual endoscopy in phantom models. A phantom pelvis was constructed of Plexiglas, porcine pelvic bones, and processed animal fat and scanned at various table speeds in a four detector-row CT machine for ability to detect "tumors" of Solidwater plastic polymer. Images were reconstructed at slice thicknesses of 2.5 to 5.0 mm and reconstructed in 3D for evaluation by two radiologists with no knowledge of the scanning parameters or tumor location. Similar studies were performed with a ureter model. With 5-mm slices, the sensitivity for bladder tumors ranged from 67% for 2-mm tumors to 100% for 4-mm tumors, with 12 false-positive findings. The overall sensitivity was 86% with 3.75-mm slices with one false positive, and with 2.5-mm slices, the sensitivity was 93%, again with one false positive. For the ureteral tumors, the overall sensitivities and numbers of false positives were 88.9% and eight with 5.0-mm collimation, 88.9% and four with 3.75-mm collimation, and 100% and three with 2.5-mm collimation. The effective radiation dose for all studies was equivalent to that of a standard abdomen/pelvis scan. Although virtual endoscopy traditionally has had difficulty detecting tumors <5 mm, the multidetector-row CT protocols used in this study could detect most lesions smaller than this. The scan also depicts the other tissues of the pelvis, which is valuable for staging. The 3D images were produced using data from the CT urogram parameters standard at our institution.

  10. Effects of arm truncation on the appearance of the halo artifact in {sup 68}Ga-PSMA-11 (HBED-CC) PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, Ali; Haberkorn, Uwe [Heidelberg University Hospital, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); Wolf, Maya; Gnirs, Regula; Schlemmer, Heinz-Peter; Freitag, Martin T. [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kachelriess, Marc [German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg (Germany); Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany)

    2017-09-15

    PSMA ligand imaging with hybrid PET/MRI scanners could be an integral part of the clinical routine in the future. However, the first study about this novel method revealed a severe photopenic artifact (''halo artifact'') around the urinary bladder causing significantly reduced tumor visibility. The aim of this evaluation was to analyze the role of arm truncation on the appearance of the halo artifact in {sup 68}Ga-PSMA-11 PET/MRI hypothesizing that this influences the appearance. Twenty-seven consecutive patients were subjected to {sup 68}Ga-PSMA-11 PET/CT (1 h p.i.) followed by PET/MRI (3 h p.i.). PET/MRI was first started with scans of the abdomen to pelvis with arms positioned up above the head. Immediately thereafter, additional scans from the pelvis to abdomen were conducted with arms positioned down beside the trunk. All investigations were first analyzed separately and then compared with respect to tumor detection and tumor uptake (SUV) as well as the presence and intensity of the halo artifact. The Wilcoxon signed rank test was used to determine statistical differences including Bonferroni correction. The halo was significantly reduced if the arms were elevated. Lesions inside the halo artifact (n = 16) demonstrated significantly increased SUVmean (p = 0.0007) and SUVmax (p = 0.0024) with arms positioned up. The halo appearance and intensity was not dependent on the total activity and activity concentration of the urinary bladder. Positioning the arms down was shown to be significantly associated with the appearance of the halo artifact in PET/MRI. Positioning the arms up above the head can significantly reduce the halo artifact, thereby detecting more tumor lesions. (orig.)

  11. Assessment of tumor heterogeneity by CT texture analysis: Can the largest cross-sectional area be used as an alternative to whole tumor analysis?

    International Nuclear Information System (INIS)

    Ng, Francesca; Kozarski, Robert; Ganeshan, Balaji; Goh, Vicky

    2013-01-01

    Objective: To determine if there is a difference between contrast enhanced CT texture features from the largest cross-sectional area versus the whole tumor, and its effect on clinical outcome prediction. Methods: Entropy (E) and uniformity (U) were derived for different filter values (1.0–2.5: fine to coarse textures) for the largest primary tumor cross-sectional area and the whole tumor of the staging contrast enhanced CT in 55 patients with primary colorectal cancer. Parameters were compared using non-parametric Wilcoxon test. Kaplan–Meier analysis was performed to determine the relationship between CT texture and 5-year overall survival. Results: E was higher and U lower for the whole tumor indicating greater heterogeneity at all filter levels (1.0–2.5): median (range) for E and U for whole tumor versus largest cross-sectional area of 7.89 (7.43–8.31) versus 7.62 (6.94–8.08) and 0.005 (0.004–0.01) versus 0.006 (0.005–0.01) for filter 1.0; 7.88 (7.22–8.48) versus 7.54 (6.86–8.1) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.01) for filter 1.5; 7.88 (7.17–8.54) versus 7.48 (5.84–8.25) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.02) for filter 2.0; and 7.83 (7.03–8.57) versus 7.42 (5.19–8.26) and 0.005 (0.003–0.01) versus 0.006 (0.004–0.03) for filter 2.5 respectively (p ≤ 0.001). Kaplan–Meier analysis demonstrated better separation of E and U for whole tumor analysis for 5-year overall survival. Conclusion: Whole tumor analysis appears more representative of tumor heterogeneity

  12. Initial diagnosis of therapeutically relevant thoracic lesions in polytraumatised patients; Zur Akutdiagnostik therapierelevanter Thoraxverletzungen bei schwer- und polytraumatisierten Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Danz, B. [Radiologische Abt., Bundeswehrkrankenhaus Ulm (Germany); Biehl, C. [Radiologische Abt., Bundeswehrkrankenhaus Ulm (Germany); Baehren, W. [Radiologische Abt., Bundeswehrkrankenhaus Ulm (Germany)

    1996-04-01

    To determine the value of supine chest radiography in comparison to orientating chest CT in the initial diagnostic evaluation of severely polytraumatised patients. 303 patients with primary indication for a cranial CT following trauma were investigated between 1988 and 1993. After performing the cranial CT all patients underwent a chest CT with an average of 6 CT slices without changing the position of the patient and with a median scan time of 4 minutes. The results of the chest CT were correlated with the findings of the supine chest radiography in regard to therapeutically relevant pathological changes. The sensitivity in detection of pneumothorax in supine chest radiography was 53% versus 97% in CT, atelectasis 20% versus 94%, lung contusion 79% versus 99%, haemotothorax 62% versus 97%. More fractures were found conventionally (sensitivity 94%) than by chest CT (sensitivity 44%). Supine chest radiography of polytraumatised patients is clearly inferior to orientating chest CT in demonstrating posttraumatic lesions; obtaining therapeutically relevant information justifies the additionally needed small amount of time. (orig.) [Deutsch] Das Ziel dieser retrospektiven Untersuchung bestand darin, die Wertigkeit der a.p. Thoraxaufnahme im Liegen im Vergleich zur orientierenden Computertomographie der Thoraxorgane im Rahmen der Akutdiagnostik bei schwer- und polytraumatisierten Patienten zu analysieren. Im Zeitraum von 1988 bis 1993 bestand bei 303 Patienten wegen eines Schaedel-Hirn-Traumas die primaere Indikation zu einem CCT. Im Anschluss an das CCT wurde routinemaessig ein orientierendes CT der Thoraxorgane mit im Durchschnitt 6 Schichten ohne Umlagerung und einem medianen Zeitaufwand von 4 Minuten durchgefuehrt. Die Befunde des CT des Thorax wurden mit den Ergebnissen der durchgefuehrten a.p. Thoraxliegendaufnahmen im Hinblick auf die Erfassung therapierelevanter pathologischer Veraenderungen verglichen. Die Sensitivitaet fuer die Erkennung eines Pneumothorax in

  13. Improved precision of interstitial brain tumor irradiation using the BRW CT stereotaxic guidance system

    International Nuclear Information System (INIS)

    Sapozink, M.D.; Moeller, J.M.; McDonald, P.N.; Heilbrun, M.P.

    1987-01-01

    A technique is described which enables precise temporary interstitial volume implantation of brain tumors using a CT stereotaxic guidance system. This technique has the advantages of designing irregular isodose distributions during the preplanning stage. Although the preplanning stage can be time-consuming, this is performed while the patient is in the hospital room and CT scanner time, anesthesia time, and operating room time is minimized for individual patients

  14. Fractures of the cervical spine. Diagnostic procedures in patients with severe cranio-cervical trauma; HWS-Frakturen. Diagnostik bei polytraumatisierten Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Link, T.M. [Inst. fuer Klinische Radiologie, Univ. Muenster (Germany); Schuierer, G. [Inst. fuer Klinische Radiologie, Univ. Muenster (Germany); Hufendiek, A. [Inst. fuer Klinische Radiologie, Univ. Muenster (Germany); Peters, P.E. [Inst. fuer Klinische Radiologie, Univ. Muenster (Germany)

    1994-12-01

    The purpose of our study was to analyze diagnostic procedures of the cervical spine in severely traumatized patients. Findings in plain radiographs and computer radiography of 234 patients were evaluated. The image quality of the plain radiographs was examined. Casualty reports were evaluated retrospectively. Frequency, distribution and morphology of cervical spine fractures were analyzed: 44 fractures in 35 patients were diagnosed, most of the fractures were located in C2 (20/44). Twenty of the fractures diagnosed in CT were not diagnosed in plain radiography and 7 fractures were uncertain findings; 5 fractures were not detected at the casualty site. A new screening procedure in patients with severe head injury is introduced. (orig.) [Deutsch] Ziel der vorliegenden Studie war, die Diagnostik der HWS beim polytraumatisierten Patienten zu analysieren. Retrospektiv wurden Roentgenaufnahmen und Computertomogramme der HWS von 234 polytraumatisierten Patienten analysiert. Konventionelle HWS-Aufnahmen wurden in bezug auf ihre Qualitaet untersucht und der Befund der konventionellen Aufnahmen mit dem der Computertomographie verglichen. Die Befunde vom Unfalltag wurden den retrospektiv validierten Befunden gegenuebergestellt. Haeufigkeit, Verteilung und Morphologie von HWS-Frakturen bei polytraumatisierten Patienten wurden untersucht: 44 Frakturen bei 35 Patienten waren nachweisbar, am haeufigsten Frakturen von HWK 2 (21/44). 20 der Frakturen konnten konventionelle radiologisch nicht und 7 nur fraglich diagnostiziert werden. 5 Frakturen wurden am Unfalltag nicht erkannt. Ein neues Untersuchungsprotokoll mit routinemaessiger computertomographischer Untersuchung von HWK 1 und 2 bei Schaedel-Hirn-Traumata wird vorgestellt. (orig.)

  15. Experimental and numerical analysis of the static and dynamic crack growth resistance behaviour of structural steels in the temperature range from 20 C to 350 C; Experimentelle und numerische Untersuchungen des statischen und dynamischen Risswiderstandsverhaltens verschiedener hoeherfester Baustaehle im Temperaturbereich von 20 C bis 350 C

    Energy Technology Data Exchange (ETDEWEB)

    Aurich, D.; Gerwien, P.; Huenecke, J.; Klingbeil, D.; Krafka, H.; Kuenecke, G.; Ohm, K.; Veith, H.; Wossidlo, P. [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Haecker, R.; 1

    1998-11-01

    The crack growth resistance behaviour of the steels StE 460 and 22NiMoCr3-7 was determined in the temperature range from 23 C to 350 C by means of C(T), M(T), and ISO-V specimens tested under quasistatic and dynamic loads. The Russian steel 15Ch2NMFA-A was tested at room temperature and 50 C. In the steels StE 460 and 22 NiMoCr3-7, the minimum crack growth resistance is observed at about 250 C, with measured values always being higher for the latter steel type. The crack growth resistance behaviour of the tested materials correlates with the behaviour of flow curve, yield strength, and notch impact toughness as a function of temperature. Impact tests of ISO-V specimens give higher crack resistance values than quasistatic load tests, and the temperature dependence is significantly lower than those of specimens tested under static loads. A metallurgical analysis of the materials shows the causes of the dissimilar behaviour. The stretching zones determined for the C(T) specimen correspond to the toughness of the steels examined, and they are not much influenced by the temperature. The numerical analysis using damaging models for simulation of ductile crack growth is reported for all specimen types and two different temperatures each. (orig./CB) [Deutsch] Mit C(T)-, M(T)- sowie quasistatisch und dynamisch geprueften ISO-V-Proben wurde das Risswiderstandsverhalten fuer die Staehle StE 460 und 22NiMoCr3-7 im Temperaturbereich von 23 C bis 350 C ermittelt, waehrend der russische Stahl 15Ch2NMFA-A fuer Raumtemperatur und fuer 50 C untersucht wurde. Das Minimum der Risszaehigkeit stellt sich bei StE 460 und 22 NiMoCr3-7 um etwa 250 C ein, wobei die Werte fuer den 22NiMoCr3-7 bei allen Temperaturen wesentlich hoeher liegen als beim StE 460. Dabei korreliert das Risswiderstandsverhalten der untersuchten Werkstoffe mit dem Verhalten von Fliesskurven, Streckgrenzen und Kerbschlagzaehigkeiten in Abhaengigkeit von der Temperatur. Schlagartig beanspruchte ISO-V-Proben liefern

  16. TNFalpha -308 C-->t and -863 C-->a polymorphisms and spermiogram characteristics.

    Science.gov (United States)

    Kurz, Christine; Bentz, Eva-Katrin; Denschlag, Dominik; Berner, Isabel; Keck, Christoph; Tempfer, Clemens B; Pietrowski, Detlef

    2008-01-01

    Genetic factors may play a role in male infertility. In a prospective case-control study, we assessed the allele and genotype frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms, detected by PCR of sperm DNA, of 577 Caucasian men recruited in an infertility clinic. Semen sampling was performed and spermiogram results were correlated to genetic data. The allele frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms were not significantly different between non-normozoospermic (n = 447) and normozoospermic (n = 130) men [758/894 (85%) and 134/894 (15%) vs. 213/269 (82%) and 43/260 (18%), p = 0.5, odds ratio (OR) 1.1, 95% confidence interval (CI) 0.74-1.76, and 749/894 (84%) and 145/894 (16%) vs. 212/260 (82%) and 48/260 (18%), p = 0.4, OR 1.2, 95% CI 0.78-1.76, respectively]. The genotype frequencies of the TNFalpha -308 C-->T and -863 C-->A polymorphisms were also not significantly different between non-normozoospermic and normozoospermic men. In addition, mutant alleles were not overrepresented in subgroups of men with the oligoasthenoteratozoospermia syndrome and asthenozoospermia. The TNFalpha -308 C-->T and -863 C-->A polymorphisms are not associated with spermiogram characteristics and do not represent molecular markers for genetic susceptibility to male infertility. Copyright 2008 S. Karger AG, Basel.

  17. Precursor B-cell lymphoblastic leukemia of the arm mimicking neurogenic tumor: case report

    Directory of Open Access Journals (Sweden)

    Sui Xiu-fang

    2012-07-01

    Full Text Available Abstract Precursor B-cell lymphoblastic lymphoma (PBLL is an infrequent subtype of lymphoblastic lymphoma (LBL that commonly affected site for the diagnosis is the skin, followed by the head and neck. In this report, we presented a special case of PBLL located at the left arm and detected with magnetic resonance imaging (MRI and ultrasonography (US. This kind of PBLL is similar to a peripheral nerve tumor in clinical and radiographic manifestation.

  18. Assessment of intratumor hypoxia by integrated 18F-FDG PET / perfusion CT in a liver tumor model.

    Directory of Open Access Journals (Sweden)

    Yong Wang

    Full Text Available Hypoxia in solid tumors occurs when metabolic demands in tumor cells surpass the delivery of oxygenated blood. We hypothesize that the 18F-fluorodeoxyglucose (18F-FDG metabolism and tumor blood flow mismatch would correlate with tumor hypoxia.Liver perfusion computed tomography (CT and 18F-FDG positron emission tomography (PET imaging were performed in twelve rabbit livers implanted with VX2 carcinoma. Under CT guidance, a fiber optic probe was inserted into the tumor to measure the partial pressure of oxygen (pO2. Tumor blood flow (BF and standardized uptake value (SUV were measured to calculate flow-metabolism ratio (FMR. Tumor hypoxia was further identified using pimonidazole immunohistochemical staining. Pearson correlation analysis was performed to determine the correlation between the imaging parameters and pO2 and pimonidazole staining.Weak correlations were found between blood volume (BV and pO2 level (r = 0.425, P = 0.004, SUV and pO2 (r = -0.394, P = 0.007, FMR and pimonidazole staining score (r = -0.388, P = 0.031. However, there was stronger correlation between tumor FMR and pO2 level (r = 0.557, P < 0.001.FMR correlated with tumor oxygenation and pimonidazole staining suggesting it may be a potential hypoxic imaging marker in liver tumor.

  19. Progress of BeiDou time transfer at NTSC

    Science.gov (United States)

    Guang, Wei; Dong, Shaowu; Wu, Wenjun; Zhang, Jihai; Yuan, Haibo; Zhang, Shougang

    2018-04-01

    Time transfer using global navigation satellite system (GNSS) is a primary method of remote atomic clock comparisons. As of today, there are four operational GNSS systems, namely GPS, GLONASS, Galileo and BeiDou Navigation Satellite System (BDS or BeiDou). All of them can continuously provide position, navigation and time services. This paper mainly focuses on the progress of BeiDou time transfer at the National Time Service Center, Chinese Academy of Sciences (NTSC). In order to realize the BeiDou common view (CV) time comparison, we developed the Rinex2CGGTTS software according to the guidelines of the Common GNSS Generic Time Transfer Standard, Version 2E (CGGTTS V2E). By comparing the solutions of the Rinex2CGGTTS software to the solutions of the sbf2cggtts software provided by the manufacturer of our multi-GNSS receiver, we found the sbf2cggtts (version 1.0.5) solutions contained biases in measurements to different BeiDou satellites. The biases are most likely caused by sbf2cggtts’ timing group delay corrections in data processing. The noise of the observation data is analyzed by code multipath and common clock difference. Finally, the BeiDou CV results are compared to the GPS/GLONASS/Galileo CV results between NTSC and three European UTC(k) laboratories, including Royal Observatory of Belgium (ORB), Real Institute y Observatory de la Armada (ROA), Research Institutes of Sweden (RISE or SP). For the comparisons of each baseline, we aligned the BeiDou/Galileo/GLONASS links to the calibrated GPS link with the double-difference method. The results show that the performance of BeiDou CV is correlated to the number of BeiDou satellites available in common view. With the current BeiDou constellation, the standard deviation of the differences between all BeiDou CV satellites averaging result and the GPS PPP result is 2.03 ns, 2.90 ns and 4.06 ns for ORB-NTSC, SP-NTSC and ROA-NTSC links respectively.

  20. Evaluation of the dose distribution of dynamic conical conformal therapy using a C-arm mounted accelerator

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Ohtomo, Kuni

    2001-01-01

    Conformal radiation therapy, which is widely utilized in Japan as a standard, highly precise technique has limited advantage in dose confinement because of its coplanar beam entry. An improved form of conformal therapy is delivered by a linac mounted on a C-arm rotatable gantry. The linac head was designed to move along the C-arm with a maximum angle of 60 degrees. Simultaneous rotation of the gantry creates a Dynamic Conical irradiation technique. Dynamic Conical Conformal Therapy (Dyconic Therapy) was developed by combining the technique with continuous MLC motion based on beam's eye views of the target volume. Dose distributions were measured in a phantom using film densitometry and compared with conventional conformal radiation therapy. The measurements showed that the dose distribution conformed to the target shape identified by CT. In addition, the dose distribution for a cancer patient was evaluated through the use of DVHs generated by a treatment planning system. These measurements showed that the dose distribution along the patient's long axis conformed to the shape of the target volume. DVH analysis, however, did not indicate superiority of the present technique over the conventional technique. Angulation of the C-arm gantry allowed the primary beam to strike a larger area of the therapy room. This necessitated adding shielding to the walls and ceiling of the treatment room. It was confirmed that the leakage radiation was reduced to a negligible level by adding an iron plate 20 cm thick to several places on the side walls, by adding an iron plate 9 cm thick to several places on the ceiling, and by increasing the thickness of the concrete ceiling from 70 to 140 cm. The possible usefulness of Dyconic Therapy was confirmed. (author)

  1. Role of carbon-11 choline PET/CT in the management of uterine carcinoma. Initial experience

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Sawada, Morio; Arai, Yasuaki; Tateishi, Ukihide; Inoue, Tomio; Maeda, Tetsuo; Sugimura, Kazuro; Terauchi, Takashi; Kano, Daisuke

    2009-01-01

    The present study was conducted to clarify the role of carbon-11 choline ( 11 C-choline) positron emission tomography (PET)/computed tomography (CT) in the management of uterine carcinoma. Twenty-two patients who underwent 11 C-choline PET/CT and pelvic MRI were evaluated retrospectively. The images were reviewed by a board-certified radiologist and a nuclear medicine specialist who were unaware of any clinical information, and a consensus was reached. Diagnostic accuracy of PET/CT was evaluated for staging. The reference standard consisted of histological examination (n=17) and follow-up conventional CT (n=5). In five patients with cervical carcinoma, 11 C-choline PET/CT was performed before and after treatment that consisted of cisplatin infusion and subsequent radiotherapy. Standardized uptake value (SUV) was compared with unidimensional and volumetric measurements that were made on magnetic resonance images (MRI) before and after treatment. Based on PET/CT interpretations, the reviewers correctly classified tumor (T) stage in 8 patients (47%), nodes (N) stage in 21 patients (96%), metastasis (M) stage in 20 patients (91%), and tumor, nodes and metastasis (TNM) stage in 15 patients (88%). Tumor size, volume, and SUV decreased after treatment in five patients with cervical carcinoma. Using the Pearson correlation test, a significant correlation was found between the reduction rate of SUV and reduction rate of tumor volume. 11 C-choline PET/CT is an accurate means for the management of patients with uterine carcinoma. The combination of 11 C-choline PET/CT and MRI increases the accuracy of staging in patients with uterine carcinoma. (author)

  2. Contemporary nuclear medicine diagnostics of neuroendocrine tumors

    Directory of Open Access Journals (Sweden)

    Todorović-Tirnanić Mila

    2015-01-01

    Full Text Available The new positron emission tomography (PET/CT methods for neuroendocrine tumors detection are presented and compared with classic, conventional methods. Conventional methods use a gamma scintillation camera for patients with neuroendocrine tumor imaging, after intravenous injection of one of the following radiopharmaceuticals: 1 somatostatin analogues labeled with indium-111 (111In-pentetreotide or technetium-99m (99mTc-EDDA/HYNIC-TOC; 2 noradrenaline analogue labeled with iodine-131 or -123 (131I/123I-MIBG; or 3 99mTc(V-DMSA. Contemporary methods use PET/CT equipment for patients with neuroendocrine tumor imaging, after intravenous injection of pharmaceuticals labeled with positron emitters [fluorine-18 (18F, galium-68 (68Ga, or carbon-11 (11C]: 1 glucose analogue (18FDG; 2 somatostatin analogue (68Ga-DOTATOC/68Ga-DOTATATE/68Ga-DOTANOC; 3 aminoacid precursors of bioamines: [a dopamine precursor 18F-DOPA (6-18F-dihydroxyphenylalanine, b serotonin precursor 11C-5HTP (11C-5-hydroxytryptophan]; or 4 dopamine analogue 18F-DA (6-18F-fluorodopamine. Conventional and contemporary (PET/ CT somatostatin receptor detection showed identical high specificity (92%, but conventional had very low sensitivity (52% compared to PET/CT (97%. It means that almost every second neuroendocrine tumor detected by contemporary method cannot be discovered using conventional (classic method. In metastatic pheochromocytoma detection contemporary (PET/ CT methods (18F-DOPA and 18F-DA have higher sensitivity than conventional (131I/123I-MIBG. In medullary thyroid carcinoma diagnostics contemporary method (18F-DOPA is more sensitive than conventional 99mTc(V-DMSA method, and is similar to 18FDG, computed tomography and magnetic resonance. In carcinoid detection contemporary method (18F-DOPA shows similar results with contemporary somatostatin receptor detection, while for gastroenteropancreatic neuroendocrine tumors it is worse. To conclude, contemporary (PET/CT methods for

  3. Bone Marrow Suppression by c-Kit Blockade Enhances Tumor Growth of Colorectal Metastases through the Action of Stromal Cell-Derived Factor-1

    Directory of Open Access Journals (Sweden)

    Kathrin Rupertus

    2012-01-01

    Full Text Available Background. Mobilization of c-Kit+ hematopoietic cells (HCs contributes to tumor vascularization. Whereas survival and proliferation of HCs are regulated by binding of the stem cell factor to its receptor c-Kit, migration of HCs is directed by stromal cell-derived factor (SDF-1. Therefore, targeting migration of HCs provides a promising new strategy of anti-tumor therapy. Methods. BALB/c mice (=16 were pretreated with an anti-c-Kit antibody followed by implantation of CT26.WT-GFP colorectal cancer cells into dorsal skinfold chambers. Animals (=8 additionally received a neutralizing anti-SDF-1 antibody. Animals (=8 treated with a control antibody served as controls. Investigations were performed using intravital fluorescence microscopy, immunohistochemistry, flow cytometry and western blot analysis. Results. Blockade of c-Kit significantly enhanced tumor cell engraftment compared to controls due to stimulation of tumor cell proliferation and invasion without markedly affecting tumor vascularization. C-Kit blockade significantly increased VEGF and CXCR4 expression within the growing tumors. Neutralization of SDF-1 completely antagonized this anti-c-Kit-associated tumor growth by suppression of tumor neovascularization, inhibition of tumor cell proliferation and reduction of muscular infiltration. Conclusion. Our study indicates that bone marrow suppression via anti-c-Kit pretreatment enhances tumor cell engraftment of colorectal metastases due to interaction with the SDF-1/CXCR4 pathway which is involved in HC-mediated tumor angiogenesis.

  4. Automated segmentation of murine lung tumors in x-ray micro-CT images

    Science.gov (United States)

    Swee, Joshua K. Y.; Sheridan, Clare; de Bruin, Elza; Downward, Julian; Lassailly, Francois; Pizarro, Luis

    2014-03-01

    Recent years have seen micro-CT emerge as a means of providing imaging analysis in pre-clinical study, with in-vivo micro-CT having been shown to be particularly applicable to the examination of murine lung tumors. Despite this, existing studies have involved substantial human intervention during the image analysis process, with the use of fully-automated aids found to be almost non-existent. We present a new approach to automate the segmentation of murine lung tumors designed specifically for in-vivo micro-CT-based pre-clinical lung cancer studies that addresses the specific requirements of such study, as well as the limitations human-centric segmentation approaches experience when applied to such micro-CT data. Our approach consists of three distinct stages, and begins by utilizing edge enhancing and vessel enhancing non-linear anisotropic diffusion filters to extract anatomy masks (lung/vessel structure) in a pre-processing stage. Initial candidate detection is then performed through ROI reduction utilizing obtained masks and a two-step automated segmentation approach that aims to extract all disconnected objects within the ROI, and consists of Otsu thresholding, mathematical morphology and marker-driven watershed. False positive reduction is finally performed on initial candidates through random-forest-driven classification using the shape, intensity, and spatial features of candidates. We provide validation of our approach using data from an associated lung cancer study, showing favorable results both in terms of detection (sensitivity=86%, specificity=89%) and structural recovery (Dice Similarity=0.88) when compared against manual specialist annotation.

  5. Radiological image interpretation for hematoma and small tumors simulated in a head and neck phantom

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio Passos Ribeiro

    2009-01-01

    Subarachnoidal hemorrhages (HSA) are caused by aneurysms and their symptom usually becomes evident after a rupture. Nevertheless, there are situations in which the aneurysms compress a nerve or produce a bleed before the rupture happens, as consequence one alert signal like headache occurs. It, often occurs after minutes or weeks previous the major rupture. The main goal is to prevent a massive hemorrhage. Thus the Computer Tomography (CT) scan of skull provides a basic and specific function: to reveal the position where the hemorrhage was produced, guiding to a additional medical procedures. On the other hand, CT does not prevent the cerebral tumor development, but precise diagnostic for some symptoms such as vomits, nauseas, epileptic attacks, weakness in arms or legs, require this image protocol. CT has its fundamental importance to tumor detection. Indeed CT reveals its importance in the tumor early diagnosis. Specialized training in CT analysis shall be done. Ahead of a precise diagnosis to manager an early intervention, a CT diagnostic training is suitable for a favorable prognostic. In this context, focusing on propose of radiological inquires; a head and neck phantom will be used to simulate hematomas and cerebral tumors. Images of CT of skull will be used to identify these lesions physically implanted in phantom. The radiological response will be analyzed with the purpose of validation of the skull's CT diagnosis, for a double blind test. The diagnostic with non contrast CT shows only higher 5mm diameter subjects (tumors) identified by the double blind test. Hemorrhage is identified by only the administrator (single-blind test). As conclusion, the author's launches the hypothesis that this object simulator shall provide assistance for specialized training on pathology interpretation on radiological images. (author)

  6. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report; Bildgebende Diagnostik des Klippel-Feil-Syndroms: Konventionelle Roentgenaufnahmen, CT und MRT. Fallbericht

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schubeus, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Menzhausen, L. [Abt. fuer Psychiatrie, Urban Krankenhaus, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1993-12-31

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [Deutsch] Anhand von zwei Patienten mit Klippel-Feil-Syndrom Typ II werden typische radiologische Befunde des Missbildungssyndroms im Bereich der Halswirbelsaeule und des kraniozervikalen Ueberganges dargestellt. Neben den konventionellen HWS-Roentgenaufnahmen und den konventionellen Schichtaufnahmen, wurden bei beiden Patienten ein CT der HWS und bei einem Patienten zusaetzlich ein MRT durchgefuehrt. Die Ergebnisse und Befunde der verschiedenen Untersuchungsverfahren werden einander gegenuebergestellt. (orig.)

  7. Evaluation of tumor invasion in gastric carcinoma with CT using water as an oral contrast agent in prone position

    International Nuclear Information System (INIS)

    Chung, Jin Il; Lee, Jong Tae; Yoo, Hyung Sik; Lee, Byung Hee; Bae, Jong Yup

    1994-01-01

    To evaluate the accuracy of CT using water as an oral contrast material in a prone position in determining the depth of tumor invasion in gastric cancer patients. Thirty three patients(19 male, 14 female) with surgically confirmed gastric cancer were studied. We performed CT in a prone position after ingestion of 1 liter of pure water. CT findings were classified into 4 groups by the morphologic appearance of infiltrates in the perigastric fat plane: normal perigastric fat(S0), fine mottled densities(S1), irregular aggregated or liner densities(S2) and direct extension and invasion of tumor into contiguous structures(S3). Also we prospectively compared the CT staging with pathologic T staging according to the TNM systems. The overall accuracy of CT staging in determining the pathologic T factor was 69.6%. As we regarded T1 and T2 lesions as one group on CT, the accuracy of CT staging was increased to 80.2% because of a limitation of CT for distinguishing T1 from T2 lesions. Prone position CT using water as an oral contrast agent is quite accurate in determining the T staging of gastric carcinoma

  8. Differential CT features between malignant mesothelioma and pleural metastasis from lung cancer or extra thoracic primary tumor mimicking malignant mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Il; Ryu, Young Hoon; Lee, Kwang Hun; Choe, Kyu Ok; Kim, Sang Jin [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    2000-01-01

    To evaluate the differential CT features found among malignant mesothelioma and pleural metastasis from lung cancer and from extra-thoracic primary tumor which on CT mimic malignant mesothelioma. Forty-four patients who on chest CT scans showed pleural thickening suggesting malignant pleural disease and in whom this condition was pathologically confirmed were included in this study. On the basis of their pathologically proven primary disease (malignant mesothelioma (n=3D14), pleural metastasis of lung cancer (n=3D18), extra thoracic primary tumor (n=3D12). They were divided into three groups. Cases of lung which on CT showed a primary lung nodule or endobronchial mass with pleural lesion, or manifested only pleural effusion, were excluded. The following eight CT features were retrospectively analyzed: (1) configuration of pleural lesion (type I, single or multiple separate nodules, type II, localized flat pleural thickening, type III, diffuse flat pleural thickening; type IV, type III with pleural nodules superimposed; type V, mass filling the hemithorax), (2) the presence of pleural effusion, (3) chest wall or rib invasion, (4) the involvement of a major fissure, (5) extra-pleural fat proliferation, (6) calcified plaque, (7) metastatic lymph nodes, (8) metastatic lung modules. In malignant mesothelioma, type IV (8/14) or II (4/14) pleural thickening was relatively frequent. Pleural metastasis of lung cancer favored type IV (8/18) or I (6/18) pleural thickening, while pleural metastasis from extrathoracic primary tumor showed a variable thickening configuration, except type V. Pleural metastasis from lung cancer and extrapleural primary tumor more frequently showed type I configuration than did malignant mesothelioma, and there were significant differences among the three groups. Fissural involvement, on the other hand, was significantly more frequent in malignant mesothelioma than in pleural metastasis from lung cancer or extrapleural primary tumor. Metastatic

  9. Thymic epithelial tumors: Comparison of CT and MR imaging findings of low-risk thymomas, high-risk thymomas, and thymic carcinomas

    International Nuclear Information System (INIS)

    Sadohara, Junko; Fujimoto, Kiminori; Mueller, Nestor L.; Kato, Seiya; Takamori, Shinzo; Ohkuma, Kazuaki; Terasaki, Hiroshi; Hayabuchi, Naofumi

    2006-01-01

    Objective: To assess the CT and magnetic resonance (MR) imaging findings of thymic epithelial tumors classified according to the current World Health Organization (WHO) histologic classification and to determine useful findings in differentiating the main subtypes. Materials and methods: Sixty patients with thymic epithelial tumor who underwent both CT and MR imaging were reviewed retrospectively. All cases were classified according to the 2004 WHO classification. The following findings were assessed in each case on both CT and MRI: size of tumor, contour, perimeter of capsule; homogeneity, presence of septum, hemorrhage, necrotic or cystic component within tumor; presence of mediastinal lymphadenopathy, pleural effusion, and great vessel invasion. These imaging characteristics of 30 low-risk thymomas (4 type A, 12 type AB, and 14 type B1), 18 high-risk thymomas (11 type B2 and seven type B3), and 12 thymic carcinomas on CT and MR imaging were compared using the chi-square test. Comparison between CT and MR findings was performed by using McNemar test. Results: On both CT and MR imaging, thymic carcinomas were more likely to have irregular contours (P < .001), necrotic or cystic component (P < .05), heterogeneous contrast-enhancement (P < .05), lymphadenopathy (P < .0001), and great vessel invasion (P < .001) than low-risk and high-risk thymomas. On MR imaging, the findings of almost complete capsule, septum, and homogenous enhancement were more commonly seen in low-risk thymomas than high-risk thymomas and thymic carcinomas (P < .05). MR imaging was superior to CT in the depiction of capsule, septum, or hemorrhage within tumor (all comparison, P < .05). Conclusion: The presence of irregular contour, necrotic or cystic component, heterogeneous enhancement, lymphadenopathy, and great vessel invasion on CT or MR imaging are strongly suggestive of thymic carcinomas. On MR imaging, the findings of contour, capsule, septum, and homogenous enhancement are helpful in

  10. (CT, MRI, USG) radiological diagnostics of neuroendocrine tumors

    International Nuclear Information System (INIS)

    Cwikla, J.; Furmanek, M.; Walecki, J.; Sankowski, A.; Pawlowska-Detko, A.

    2007-01-01

    Neuroendocrine tumors (NET) consists of a heterogeneneous group of neoplasma, that are able to express cell membrane neuroamine uptake mechanisms and/or specific receptors, which can be used in the localization and treatment of these tumours. Conventionally NETs may present with a wide variety of functional or nonfuctional endocrinesyndromes and may be familial and have other associated tumors, also they have different histology and prognosis. They originate from endocrine glands such as the pituitary, the parathyroids, and the neuroendocrine) adrenal, as well as endocrine islets within glandular tissue (thyroid or pancreatic) and cells dispersed between exocrine cells, such as endocrine cells of the digestive system (gastroenteropancreatic GEP-NET0 and respiratory tracts. GEp-NET are the the most common including more 70% of all NETs. Imaging modalities and assessment of specific tumors markers offers high sensitivity in establishing the diagnosis and can also have pronostic significance. One of most important single imaging techniques in terms of initial identification and staging o GET-NET are CT and somatostatin receptor scintigraphy (SRS). Other investigation like magnetic resonance imaging (MRI), endoscopic (EUS) are used for the precise localization of GEP-NET. Another techniques including functional approach 123 I MIBG (meta-iodobenzylguanidine scintigraphy) and FDG PET.Important using of imaging approach is monitoring of response on treatment. (author)

  11. Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Hara, Ryusuke; Yanagi, Takeshi; Sharp, Gregory C.; Kumagai, Motoki; Asakura, Hiroshi; Kishimoto, Riwa; Yamada, Shigeru; Kandatsu, Susumu; Kamada, Tadashi

    2009-01-01

    Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors.

  12. Pulmonary granulomatous diseases and pulmonary manifestations of systemic granulomatous disease. Including tuberculosis and nontuberculous mycobacteriosis; Pulmonale granulomatoese Erkrankungen und pulmonale Manifestationen systemischer Granulomatosen. Inklusive Tuberkulose und nichttuberkuloese Mykobakteriosen

    Energy Technology Data Exchange (ETDEWEB)

    Piel, S. [Universitaet Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Thoraxklinik, Heidelberg (Germany); Kreuter, M.; Herth, F. [Universitaet Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Thoraxklinik, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kauczor, H.U. [Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Heussel, C.P. [Universitaet Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Thoraxklinik, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany)

    2016-10-15

    Granulomas as signs of specific inflammation of the lungs are found in various diseases with pulmonary manifestations and represent an important imaging finding. The standard imaging modality for the work-up of granulomatous diseases of the lungs is most often thin-slice computed tomography (CT). There are a few instances, e. g. tuberculosis, sarcoidosis and silicosis, where a chest radiograph still plays an important role. Further radiological modalities are usually not needed in the routine work-up of granulomatous diseases of the chest. In special cases magnetic resonance imaging (MRI) and positron emission tomography (PET)-CT scans play an important role, e. g. detecting cardiac sarcoidosis by cardiac MRI or choline C-11 PET-CT in diagnosing lung carcinoma in scar tissue after tuberculosis. The accuracy of thin-slice CT is very high for granulomatous diseases. In cases of chronic disease and fibrotic interstitial lung disease it is important to perform thin-slice CT in order to diagnose a specific disease pattern. Thin-slice CT is also highly sensitive in detecting disease complications and comorbidities, such as malignancies. Given these indications thin-slice CT is generally accepted in the routine daily practice. A thin-slice CT and an interdisciplinary discussion are recommended in many cases with a suspected diagnosis of pulmonary granulomatous disease due to clinical or radiographic findings. (orig.) [German] Granulome als Zeichen der spezifischen Entzuendung im Lungengewebe treten bei zahlreichen Erkrankungen mit pulmonaler Manifestation auf und stellen einen wichtigen Befund in der Bildgebung dar. Das radiologische Standardverfahren bei pulmonalen Granulomatosen ist meistens die Duennschichtcomputertomographie, in wenigen Faellen, wie z. B. bei Tuberkulose, Sarkoidose und Silikose, spielt die Roentgenthoraxuebersicht immer noch eine wichtige Rolle. Bei der Standardabklaerung der meisten Granulomatosen ist die Hinzunahme weiterer Verfahren nicht

  13. A case of primary neuroendcrine tumor of liver with FDG accumulation by PET/CT

    International Nuclear Information System (INIS)

    Okumura, Yoshihiro; Kishi, Ryotaro; Uka, Mayu; Tsuchihashi, Kazuyo; Hyodo, Takeshi; Takakura, Norihisa; Iguchi, Toshihiro; Kanazawa, Susumu

    2014-01-01

    We report an 80's male with primary hepatic neuroendcrine tumor without clinical symptom. dynamic contrast CT showed a hypervascular tumor at S5 of the liver. EOB-MRI showed high intensity on T2WI, low intensity on T1WI, the hepatic phase and the diffusion weighted image. It showed high FDG accumulation. Pathological examination confirmed neuroendcrine tumor of liver, G2 stage, and owing to the CD56 positive, 12.6% at MIB-1 index, with a little necrosis, no capsule and hemorrhage. (author)

  14. Video-assisted breast surgery and 3-dimensional computed tomographic mammary lymphography (2). Sentinel node biopsy with 3D-CT mammary lymphography

    International Nuclear Information System (INIS)

    Yamashita, Koji

    2010-01-01

    I have studied endoscopic surgery for breast diseases and 3-dimensional (3D) computed tomographic (CT) lymphography for sentinel node (SN) biopsy. In this second in a series of reports, I explain the techniques of 3D-CT lymphography. 3D-CT lymphography can show the detailed lymphatic flow from the breast tumor toward the SNs and the exact local relation between axillary lymph nodes. I have developed this 3D image-processing system to more precisely depict the anatomical structures of the mammary lymphovascular system. This system allows us to systematically collect axillary lymph nodes, including SNs. 3D-CT lymphography was performed to mark SNs on the skin on the day before surgery. Above the tumor and near the areola, 2 ml of Iopamiron 300 was injected subcutaneously. Sixteen-channel multidetector-row helical CT scan images were obtained 1 minute after injection to detect SNs, and after 3 and 5 minutes to observe lymph flow into the venous angle. The scan images were reconstructed to produce 3D images. SN biopsy was performed with the dye-staining method and endoscopy. 3D-CT lymphography accurately showed lymphatic flow from the tumor to SNs. We classified the relationship between the lymph ducts and the drained SNs into 4 patterns. Following up 3 and 5 minutes after injection of the contrast agent, we can follow the lymph ducts beyond the SN into the second and third nodes toward the venous angle with the complex plexus. The figure of the axillary nodes shows 5 beads-like grouped nodes. 3D-CT lymphography can also recognize the metastatic patterns of the enhanced lymph node. These patterns will predict the metastasis before SN biopsy. 3D-CT lymphography can also be used to detect lymph flow from the arm to avoid harming the arm lymph channel during axillary node dissection and SN biopsy. With 3D-CT lymphography, we can more accurately and precisely recognize lymph flow and the positional relations of SN and axillary nodes to surrounding anatomical structures

  15. CT-assisted transcutaneous interstitial implantation of thoracic tumors: Early experience

    International Nuclear Information System (INIS)

    Heelan, R.T.; Hilaris, B.S.; Anderson, L.; Caravelli, J.F.; Nori, D.; Martini, N.; Watson, R.C.; Linares, L.

    1986-01-01

    The authors have transcutaneously implanted I-125 radioactive seeds in six patients with thoracic tumors (three with lung cancer; three with metastases) to determine the feasibility of this procedure. In four patients the thoracic tumors were localized without evidence of distant metastases, but these patients were not candidates for resection because of chronic pulmonary disease. Tumor volume was measured on CT scans (with sagittal and coronal reconstructions) and the required number of seeds was determined based on tumor volume. Between 6 and 11 needles were placed in the tumor and the seeds were implanted as the needle was withdrawn. Between 40 and 60 seeds were implanted in each patient, under local anesthesia. In this preliminary series all patients were found to have tumor attached to pleura. Four of the six patients underwent implantation during a day-time admission to the institution's Adult Day Hospital. No patient suffered any complication as a result of the procedure. Four patients experienced a symptomatic relief of pain and a decrease in size of tumor bulk (local control). Two patients eventually exhibited renewed tumor growth in the edges of the implanted mass after 6 months; the authors plan to supplement future implantations with external radiation therapy. One patient underwent implantation after local recurrence of tumor, returned to work the day following the procedure, and is without evidence of local recurrence 18 months later. They are encouraged by these preliminary results, for several reasons: the lack of morbidity, the achievement of local control of tumor while avoiding surgery and its potential complications, and avoidance of hospital stay (with consequent financial savings). The intent is to expand this series to include patients with lung tumors not attached to pleura

  16. CT Findings of Intrarenal Yolk Sac Tumor with Tumor Thrombus Extending into the Inferior Vena Cava: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shao Chun; Li, Xue Hua; Sun, Can Hui; Feng, Shi Ting; Peng, Zhen Peng; Huang, Si Yun; Li, Zi Ping [Dept. of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China)

    2014-10-15

    Yolk sac tumor (YST) is a rare germ cell neoplasm of childhood that usually arises from the testis or ovary. The rare cases of YST in various extragonadal locations have been reported, but the primary intrarenal YST is even more uncommon. Here, we report a case of a primary intrarenal YST with tumor thrombus of the inferior vena cava and left renal vein in a 2-year-old boy, with an emphasis on the CT features. To our knowledge, this is the first reported case of an intrarenal YST with intravascular involvement.

  17. 64Cu-DOTA-Anti-CTLA-4 mAb Enabled PET Visualization of CTLA-4 on the T-Cell Infiltrating Tumor Tissues

    Science.gov (United States)

    Higashikawa, Kei; Yagi, Katsuharu; Watanabe, Keiko; Kamino, Shinichiro; Ueda, Masashi; Hiromura, Makoto; Enomoto, Shuichi

    2014-01-01

    Cytotoxic T lymphocyte-associated antigen-4 (CTLA-4) targeted therapy by anti-CTLA-4 monoclonal antibody (mAb) is highly effective in cancer patients. However, it is extremely expensive and potentially produces autoimmune-related adverse effects. Therefore, the development of a method to evaluate CTLA-4 expression prior to CTLA-4-targeted therapy is expected to open doors to evidence-based and cost-efficient medical care and to avoid adverse effects brought about by ineffective therapy. In this study, we aimed to develop a molecular imaging probe for CTLA-4 visualization in tumor. First, we examined CTLA-4 expression in normal colon tissues, cultured CT26 cells, and CT26 tumor tissues from tumor-bearing BALB/c mice and BALB/c nude mice by reverse transcription polymerase chain reaction (RT-PCR) analysis and confirmed whether CTLA-4 is strongly expressed in CT26 tumor tissues. Second, we newly synthesized 64Cu-1,4,7,10-tetraazacyclododecane-N,N′,N″,N‴-tetraacetic acid-anti-mouse CTLA-4 mAb (64Cu-DOTA-anti-CTLA-4 mAb) and evaluated its usefulness in positron emission tomography (PET) and ex-vivo biodistribution analysis in CT26-bearing BALB/c mice. High CTLA-4 expression was confirmed in the CT26 tumor tissues of tumor-bearing BALB/c mice. However, CTLA-4 expression was extremely low in the cultured CT26 cells and the CT26 tumor tissues of tumor-bearing BALB/c nude mice. The results suggested that T cells were responsible for the high CTLA-4 expression. Furthermore, 64Cu-DOTA-anti-CTLA-4 mAb displayed significantly high accumulation in the CT26 tumor, thereby realizing non-invasive CTLA-4 visualization in the tumor. Together, the results indicate that 64Cu-DOTA-anti-CTLA-4 mAb would be useful for the evaluation of CTLA-4 expression in tumor. PMID:25365349

  18. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  19. Splenosis Mimicking Relapse of a Neuroendocrine Tumor at Gallium-68-DOTATOC PET/CT

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Luca, Giovanella; Barbara, Muoio; Carmelo, Caldarella

    2014-01-01

    A 48-year-old female patient underwent splenopancreasectomy for a 4-cm pancreatic neuroendocrine tumor (pNET), grade G2, located in the pancreatic tail. One year after surgery, the patient presented an increased serum level of the tumor marker chromogranin A (value: 160 U/l). Therefore, she underwent somatostatin receptor PET/CT using gallium-68-DOTATOC for restaging. This imaging method showed a focal area of increased radiopharmaceutical uptake corresponding to a 2.5-cm nodule located in the left superior abdomen near a clip from the previous surgery, suggesting a possible relapse of pNET. Based on this PET/CT finding, the patient underwent ultrasonography-guided core biopsy of this nodule. Histology did not reveal findings suggestive of pNET but identified spleen tissue most likely caused by splenosis accidentally seeded at the previous operation. It is likely that the increased serum level of the tumor marker chromogranin A was due to the chronic proton-pump inhibitors use. Somatostatin receptor PET/CT is an accurate imaging method for staging and restaging pNET, presenting high sensitivity and specificity in this setting. Nevertheless, possible sources of false-negative and -positive findings with this method should be taken into account. Inflammatory lesions represent the most frequent causes of false-positive findings for pNET at somatostatin receptor imaging because inflammatory cellsmay overexpress somatostatin receptors on their cell surface. In our case, we showed that splenosis may represent a possible cause of false-positive findings for pNET relapse due to the physiological uptake of somatostatin analogs by the spleen tissue

  20. Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm.

    Science.gov (United States)

    Watanabe, E; Mayanagi, Y; Kosugi, Y; Manaka, S; Takakura, K

    1991-06-01

    A new computed tomographic-stereotactic device that translates the operating point onto preoperative computed tomographic (CT) images, the Neuronavigator, has been developed. We have applied this system to various neurosurgical procedures to examine its usefulness. The system consists of a 6-joint sensing arm and a 16-bit personal computer. It projects the location of the arm tip onto a corresponding CT slice with a cursor that guides the surgeon toward the intracranial target during open surgery. The system also projects the location of the tip onto angiograms, and when used in conjunction with echography or a transcranial Doppler (TCD) flow meter, the surgeon's ability to navigate is enhanced. Sixty-eight patients underwent operation with the Neuronavigator. The navigation system worked as the core of a multimodal three-dimensional data base that proved to be useful during surgery. The maximum detection error was 2.5 mm, which was considered sufficient for open microsurgery. It also proved useful in designing the position of a craniotomy, in targeting deep-seated mass lesions, and in tracing the tumor edge, which had been identified on a CT scan. When the angiogram was combined with the navigator, it became easy to identify key vessels within a small operating field. The system was also combined with a TCD flow meter. This combination makes it possible to translate the measuring point of the TCD directly into CT coordinates, improving the precision of location of the TCD probe. The Neuronavigator combines various diagnostic images into one database and effectively guides the surgeon during surgery.

  1. Adenocarcinomas of the esophagus: Response to chemoradiotherapy is associated with decrease of metabolic tumor volume as measured on PET-CT

    International Nuclear Information System (INIS)

    Roedl, Johannes B.; Colen, Rivka R.; Holalkere, Nagaraj S.; Fischman, Alan J.; Choi, Noah C.; Blake, Michael A.

    2008-01-01

    Purpose: We determined whether evaluation of treatment response is feasible by measuring metabolic tumor volume parameters on 18F-FDG (Fluorodeoxyglucose) PET-CT (Positron emission tomography-Computed tomography). We compared the response evaluation based on metabolic tumor volume parameters to a histopathologic and clinical response evaluation (clinical response criteria: RECIST criteria = Response evaluation criteria in solid tumors, and WHO criteria = World health organization). Patients and methods: A total of 51 study subjects with adenocarcinomas (Type I due to Siewert classification) of the esophagus underwent PET-CT scans before and after neoadjuvant chemoradiotherapy. Tumor volume, maximum and mean standardized uptake values (SUV) were assessed before and after chemoradiotherapy. Furthermore, the total lesion glycolysis (TLG) was calculated by multiplying the tumor volume by the mean SUV of the volume. Clinical response evaluation was performed with endoscopic ultrasound and CT using RECIST and WHO criteria. The reference standard for treatment response was the postsurgical histopathology. Results: The decrease of tumor volume between the pre- and post-treatment PET-CT scans was a better predictor of histopathologic response and survival than the decrease of the SUV and of the clinical response evaluation based on RECIST and WHO criteria. The highest accuracy, however, was achieved when using the TLG for the identification of treatment responders. A decrease of the TLG by >78% between pre- and post-therapy scans predicted histopathologic response with a sensitivity and specificity of 91% and 93%, respectively. Conclusions: Tumor volume and TLG can be used to assess treatment response and survival in patients with esophageal adenocarcinoma

  2. Locoregionally advanced carcinoma of the oropharynx: conventional radiotherapy vs. accelerated hyperfractionated radiotherapy vs. concomitant radiotherapy and chemotherapy - a multicenter randomized trial

    International Nuclear Information System (INIS)

    Olmi, Patrizia; Crispino, Sergio; Fallai, Carlo; Torri, Valter; Rossi, Francesca; Bolner, Andrea; Amichetti, Maurizio; Signor, Marco; Taino, Raffaella; Squadrelli, Massimo; Colombo, Alessandro; Ardizzoia, Alessandro; Ponticelli, Pietro; Franchin, Giovanni; Minatel, Emilio; Gobitti, Carlo; Atzeni, Guido; Gava, Alessandro; Flann, Monica; Marsoni, Silvia

    2003-01-01

    Purpose: To compare conventional fractionation radiation therapy (RT), Arm A, vs. split-course accelerated hyperfractionated RT (S-AHF), Arm B, vs. conventional fractionation RT plus concomitant chemotherapy (CT), Arm C, in terms of survival and toxicity for advanced, unresectable epidermoid tumors of oropharynx. Methods and Materials: Between January 1993 and June 1998, 192 previously untreated patients affected with Stage III and IV oropharyngeal carcinoma (excluding T1N1 and T2N1) were accrued in a multicenter, randomized Phase III trial (ORO 93-01). For Arms A and C, 66-70 Gy in 33-35 fractions, 5 days a week, were administered in 6.5-7 weeks to tumor and positive nodes. In Arm B, the dose delivered to tumor and involved nodes was 64-67.2 Gy, giving 2 fractions of 1.6 Gy every day with an interfraction interval of at least 4 h and preferably 6 h, 5 days a week. At 38.4 Gy, a 2-week split was planned; after the split, RT was resumed with the same modality. In Arm C, CT regimen consisted of carboplatin and 5-fluorouracil (CBDCA 75 mg/m 2 , Days 1-4; 5-FU 1,000 mg/m 2 i.v. over 96 h, Days 1-4, recycling every 28 days (at 1st, 5th, and 9th week). Results: No statistically significant difference was detected in overall survival (p=0.129): 40% Arm A vs. 37% Arm B vs. 51% Arm C were alive at 24 months. Similarly, there was no statistically significant difference in terms of event-free survival (p=0.196): 20% for Arm A, 19% for Arm B, and 37% for Arm C were event free at 24 months. On the contrary, the 2-year disease-free survival was significantly different among the three arms (p = 0.022), with a superiority for Arm C. At 24 months, the proportion of patients without relapse was 42% for Arm C vs. 23% for Arm A and 20% for Arm B. Patients in Arm A less frequently developed G3+ acute mucositis than their counterparts in Arm B or C (14.7% vs. 40.3% vs. 44%). Regarding the CT-related acute toxicity, apart from 1 case of fatal nephrotoxicity, only hematologic G3+ (Grade 3

  3. Diagnostic difficulties in the differentiation of neurogenic tumors of the parapharyngeal space in helical CT evaluations: A case report

    International Nuclear Information System (INIS)

    Czerniewicz-Kaminska, A.; Nowicki, J.; Jazwiec, P.; Kedzierski, B.; Janeczek, T.; Wilczynski, K.; Prudlak, E.

    2005-01-01

    Computerized tomography (CT) with contrast infusion and magnetic resonance imaging (MRI) play important roles in establishing the place of origin of neurogenic tumors. In this article we do not compare these two methods, but focus on the crucial role of CT imaging in the estimation and differential diagnosis of these tumors. We present the case of a 50-year-old man with clinical symptoms of peritonsillar abscess, which appeared to be a neurogenic tumor. The images obtained were deemed ambiguous. The possibility of a parotid gland tumor or a tumor of neurogenic origin was assumed. In this case we observed atypical clinical and radiological symptoms. The final diagnosis was based on a combination of radiological, clinical, and microbiological features of the tumor. Thanks to the cooperation of many professionals, we managed to establish the diagnosis of neuroangiofibroma, which exemplifies a tumor of the borderline, including elements of the neurogenic sheath and connective and chromaffin tissue. (author)

  4. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  5. Iatrogenic intraspinal epidermoid tumor: Myelo-CT and MRI diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Visciani, A.; Balestrini, M.R.; Solero, C.L.; Savoiardo, M.

    1989-07-01

    An 11-year-old boy, treated for acute lymphatic leukemia at the age of 2 with intrathecal injections of Methotrexate, presented with a two year history of pain and signs of lumbo-sacral lesion. MRI, myelography and myelo-CT demonstrated an intradural L4-L5 epidermoid tumor which was removed. Iatrogenic implantation of epithelial cells at the age of two with lumbar punctures is most likely. Decline in incidence of lumbar iatrogenic epidermoid cysts, now an exceedingly rare event, is probably related to improved needles for lumbar punctures. (orig.).

  6. Iatrogenic intraspinal epidermoid tumor: Myelo-CT and MRI diagnosis

    International Nuclear Information System (INIS)

    Visciani, A.; Balestrini, M.R.; Solero, C.L.; Savoiardo, M.

    1989-01-01

    An 11-year-old boy, treated for acute lymphatic leukemia at the age of 2 with intrathecal injections of Methotrexate, presented with a two year history of pain and signs of lumbo-sacral lesion. MRI, myelography and myelo-CT demonstrated an intradural L4-L5 epidermoid tumor which was removed. Iatrogenic implantation of epithelial cells at the age of two with lumbar punctures is most likely. Decline in incidence of lumbar iatrogenic epidermoid cysts, now an exceedingly rare event, is probably related to improved needles for lumbar punctures. (orig.)

  7. Mesenchymal abdominal tumors in children; Mesenchymale Tumoren des Abdomens bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A. [Justus-Liebig Universitaet Giessen, Klinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Giessen, Giessen (Germany)

    2018-01-15

    Mesenchymal tumors in childhood comprise benign and malign entities and differ regarding typical sites of manifestation, age peak and clinical symptoms. In some cases biopsy is mandatory. If nephroblastoma is a possible diagnosis, biopsy must be avoided by all means in order to avoid biopsy tract metastasis. Imaging is used to narrow the differential diagnosis, describe the exact extent of the lesion and deliver complete staging. In pediatric patients sonography and MRI are the most important imaging modalities. Low-dose CT of the thorax serves for assessment of possible pulmonary metastases. (orig.) [German] Mesenchymale Tumoren im Kindesalter umfassen eine Reihe gutartiger und boesartiger Entitaeten, die sich hinsichtlich Praedilektionsort und Altersgipfel sowie bezueglich der klinischen Symptome voneinander unterscheiden. In manchen Faellen ist eine Biopsie unumgaenglich. Ist als Differenzialdiagnose ein Nephroblastom moeglich, darf auf keinen Fall biopsiert werden, um eine Zellverschleppung zu vermeiden. Aufgabe der Bildgebung ist die Eingrenzung der Differenzialdiagnose und die Bestimmung der Ausdehnung, einschliesslich des Stagings. Ultraschall und Magnetresonanztomographie (MRT) stellen diesbezueglich die wichtigsten Modalitaeten dar, die Niedrigdosis-Computertomographie des Thorax wird zum Ausschluss einer pulmonalen Metastasierung herangezogen. (orig.)

  8. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

    Science.gov (United States)

    Lee, Kisung; Lee, Kyoung Min; Park, Moon Seok; Lee, Boram; Kwon, Dae Gyu; Chung, Chin Youb

    2012-06-15

    Measurement of radiation dose from C-arm fluoroscopy during a simulated intraoperative use in spine surgery. OBJECTIVE.: To investigate scatter radiation doses to specific organs of surgeons during intraoperative use of C-arm fluoroscopy in spine surgery and to provide practical intraoperative guidelines. There have been studies that reported the radiation dose of C-arm fluoroscopy in various procedures. However, radiation doses to surgeons' specific organs during spine surgery have not been sufficiently examined, and the practical intraoperative radioprotective guidelines have not been suggested. Scatter radiation dose (air kerma rate) was measured during the use of a C-arm on an anthropomorphic chest phantom on an operating table. Then, a whole body anthropomorphic phantom was located besides the chest phantom to simulate a surgeon, and scatter radiation doses to specific organs (eye, thyroid, breast, and gonads) and direct radiation dose to the surgeon's hand were measured using 4 C-arm configurations (standard, inverted, translateral, and tube translateral). The effects of rotating the surgeon's head away from the patient and of a thyroid shield were also evaluated. Scatter radiation doses decreased as distance from the patient increased during C-arm fluoroscopy use. The standard and translateral C-arm configurations caused lower scatter doses to sensitive organs than inverted and tube translateral configurations. Scatter doses were highest for breast and lowest for gonads. The use of a thyroid shield and rotating the surgeon's head away from the patient reduced scatter radiation dose to the surgeon's thyroid and eyes. The direct radiation dose was at least 20 times greater than scatter doses to sensitive organs. The following factors could reduce radiation exposure during intraoperative use of C-arm; (1) distance from the patient, (2) C-arm configuration, (3) radioprotective equipments, (4) rotating the surgeons' eyes away from the patient, and (5) avoiding

  9. Optimal CT scanning parameters for commonly used tumor ablation applicators

    International Nuclear Information System (INIS)

    Eltorai, Adam E.M.; Baird, Grayson L.; Monu, Nicholas; Wolf, Farrah; Seidler, Michael; Collins, Scott; Kim, Jeomsoon; Dupuy, Damian E.

    2017-01-01

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  10. Optimal CT scanning parameters for commonly used tumor ablation applicators

    Energy Technology Data Exchange (ETDEWEB)

    Eltorai, Adam E.M. [Warren Alpert Medical School of Brown University (United States); Baird, Grayson L. [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Lifespan Biostatistics Core (United States); Rhode Island Hospital (United States); Monu, Nicholas; Wolf, Farrah; Seidler, Michael [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States); Collins, Scott [Department of Diagnostic Imaging (United States); Rhode Island Hospital (United States); Kim, Jeomsoon [Department of Medical Physics (United States); Rhode Island Hospital (United States); Dupuy, Damian E., E-mail: ddupuy@comcast.net [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States)

    2017-04-15

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  11. SU-C-202-04: Adapting Biologically Optimized Dose Escalation Based On Mid-Treatment PET/CT for Non-Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, P; Kuo, L; Yorke, E; Hu, Y; Lockney, N; Mageras, G; Deasy, J; Rimner, A [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To develop a biological modeling strategy which incorporates the response observed on the mid-treatment PET/CT into a dose escalation design for adaptive radiotherapy of non-small-cell lung cancer. Method: FDG-PET/CT was acquired midway through standard fractionated treatment and registered to pre-treatment planning PET/CT to evaluate radiation response of lung cancer. Each mid-treatment PET voxel was assigned the median SUV inside a concentric 1cm-diameter sphere to account for registration and imaging uncertainties. For each voxel, the planned radiation dose, pre- and mid-treatment SUVs were used to parameterize the linear-quadratic model, which was then utilized to predict the SUV distribution after the full prescribed dose. Voxels with predicted post-treatment SUV≥2 were identified as the resistant target (response arm). An adaptive simultaneous integrated boost was designed to escalate dose to the resistant target as high as possible, while keeping prescription dose to the original target and lung toxicity intact. In contrast, an adaptive target volume was delineated based only on the intensity of mid-treatment PET/CT (intensity arm), and a similar adaptive boost plan was optimized. The dose escalation capability of the two approaches was compared. Result: Images of three patients were used in this planning study. For one patient, SUV prediction indicated complete response and no necessary dose escalation. For the other two, resistant targets defined in the response arm were multifocal, and on average accounted for 25% of the pre-treatment target, compared to 67% in the intensity arm. The smaller response arm targets led to a 6Gy higher mean target dose in the adaptive escalation design. Conclusion: This pilot study suggests that adaptive dose escalation to a biologically resistant target predicted from a pre- and mid-treatment PET/CT may be more effective than escalation based on the mid-treatment PET/CT alone. More plans and ultimately clinical

  12. CT diagnosis and differentiation of benign and malignant varieties of solitary fibrous tumor of the pleura.

    Science.gov (United States)

    You, Xiaofang; Sun, Xiwen; Yang, Chunyan; Fang, Yong

    2017-12-01

    To investigate computed tomography (CT) characteristics of benign and malignant solitary fibrous tumors of the pleura (SFTPs).Preoperative CTs for 60 SFTP cases (49 benign and 11 malignant) with subsequently confirmed diagnoses were retrospectively analyzed.Tumor morphologies included mounded or mushroom umbrella-shape (19 cases, 31.7%), quasi-circular or oval-shape (30 cases, 50%), and growth resembling a casting mould (12 cases, 20%). Maximum tumor diameters were 1.1 to 18.9 cm (average: 6.4 ± 4.8 cm). Fifty-seven cases had clear boundaries, and 3 had partially coarse boundaries. Twenty-seven cases showed homogeneous density; 33, "geographic"-patterned inhomogeneous density; 6, calcifications; 12, intratumor blood vessels; and 3, thick nourishing peritumoral blood vessels. Pleural thickening (regular and irregular) was found adjacent to tumors in 4, compression of adjacent ribs with absorption and cortical sclerosis in 2, and location adjacent to ribs with bony destruction in 1. Four cases had a small amount of lung tissue enfolded along the boundary, 2 had multiple peritumoral pulmonary bullae, and 9 had small ipsilateral pleural effusions. Compared with benign and malignant SFTPs were larger (P < .001), had inhomogeneous density, and were more commonly associated with intratumor blood vessels and pleural effusions (P < .01).CT revealed characteristic patterns in SFTPs, including casting mould-like growth, rich blood supply, and "geographic"-patterned enhancement. In addition, larger tumor size, inhomogeneous intensities, abundant intratumor blood vessels, and pleural effusions were more common with malignancy. Lastly, multislice CT angiography can reveal feeding arteries and help guide surgical management.

  13. Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Ramsey, Chester; Meeks, Sanford L.; Willoughby, Twyla R.; Forbes, Alan; Wagner, Thomas H.; Langen, Katja M.

    2005-01-01

    Purpose: The ability to obtain soft-tissue imaging in the treatment room, such as with megavoltage CT imaging, enables the observation of tumor regression during a course of external beam radiation therapy. In this current study, we report on the most extensive study looking at the rate of regression of non-small-cell lung cancers during a course of external beam radiotherapy by analyzing serial megavoltage CT images obtained on 10 patients. Methods and Materials: The analysis is performed on 10 patients treated with the Helical Tomotherapy Hi*Art device. All 10 patients had non-small-cell lung cancer. A total of 274 megavoltage CT sets were obtained on the 10 patients (average, 27 scans per patient; range, 9-35). All patients had at least a scan at beginning and at the end of treatment. The frequency of scanning was determined by the treating physician. The treatment was subsequently delivered with the Tomotherapy Hi*Art system. The gross tumor volumes (GTVs) were later contoured on each megavoltage CT scan, and tumor volumes were calculated. Although some patients were treated to draining nodal areas in addition to the primary tumor, only the primary GTVs were tracked. Response to treatment was quantified by the relative decrease in tumor volume over time, i.e., elapsed days from the first day of therapy. The individual GTVs ranged from 5.9 to 737.2 cc in volume at the start of treatment. In 6 of the 10 patients, dose recalculations were also performed to document potential variations in delivered doses within the tumors. The megavoltage CT scans were used, and the planned treatment was recalculated on the daily images. The hypothesis was that dose deposited in the target would increase throughout the course of radiotherapy because of tumor shrinkage and subsequent decreasing attenuation. Specifically, the dose received by 95% of the GTV (D 95 ) was monitored over time for each of the 6 patients treated at M.D. Anderson Cancer Center Orlando. Results: Regression

  14. CT volumetric measurement of colorectal cancer helps predict tumor staging and prognosis.

    Directory of Open Access Journals (Sweden)

    Jin Young Park

    Full Text Available To evaluate feasibility of CT colonography (CTC volumetry of colorectal cancer (CRC and its correlation with disease stage and patients' survival.CTC volumetry was performed for 126 patients who underwent preoperative CTC. Reproducibility of tumor volume (Tvol between two readers was assessed. One-way ANOVA and ROC analysis evaluated correlation between Tvol and pTNM staging. ROC analysis compared diagnostic performance to predict pTNM staging between Tvol and radiologist. Kaplan-Meier test compared overall survival.Reproducibility among readers was excellent (interclass correlation = 0.9829. Mean Tvol showed an incremental trend with T stage and Tvol of pT4b stage was significantly larger than other stages (P0.05. Smaller tumor burden (≤12.85cm3, ≤T3, N0, M0 stages, and curative surgery were significantly associated with patients' longer survival (P<0.05.CT volumetry has a limited value to predict N stage; however, it may outperform the radiologist's performance when predicting pT4b and M1b stage and can be a useful prognostic marker.

  15. Clinical application of SPECT-CT with 99mTc-Tektrotyd in bronchial and thymic neuroendocrine tumors (NETs).

    Science.gov (United States)

    Sergieva, Sonya; Robev, Bozhil; Dimcheva, Milena; Fakirova, Albena; Hristoskova, Radka

    2016-01-01

    Neuroendocrine tumors (NETs) of the thorax including bronchial and thymic tumors belong to foregut NETs. Limited loco-regional thoracic NETs can be resected with surgery, but in extensive metastatic disease the treatment is mainly palliative. A high incidence and density of somatostatin receptors (SSTR2, SSTR3, and SSTR5) are found in thoracic NETs. The purpose of this study was to evaluate the role of SPECT-CT somatostatin receptor scintigraphy (SRS) with 99mTc-Tektrotyd for imaging, staging and follow up of patients with bronchial and thymic neuroendocrine tumors. Forty-one patients with thoracic tumors with neuroendocrine differentiation were studied. Sixty-eight examinations including SPECT-CT studies of the neck and chest and/or abdomen and pelvis were carried out 2-4 hrs. post i.v. administration of aver-age 740 MBq activity dose of 99mTc-EDDA/HYNIC-TOC (Tektrotyd, Polatom). In all 41 investigated patients we obtained 81.25% (13/16), 88% (22/25) and 85.36% (35/41) of sensitivity, specificity and accuracy of this diagnostic approach, respectively. Somatostatin-receptor scintigraphy correctly identified all primary NETs located in the lungs and thymus. SPECT-CT studies with 99mTc-EDDA/HYNIC-TOC resulted in exact pre-surgical and pre-treatment N/M staging of bronchial and thymic NETs, except 2 cases with multiple hepatic metastases and 1 with massive suprarenal metastasis. It can be concluded that SPECT-CT with 99mTc-EDDA/HYNIC-TOC is a valuable tool for staging and follow-up of patients with thoracic NETs.

  16. Combining PET/CT with serum tumor markers to improve the evaluation of histological type of suspicious lung cancers.

    Science.gov (United States)

    Jiang, Rifeng; Dong, Ximin; Zhu, Wenzhen; Duan, Qing; Xue, Yunjing; Shen, Yanxia; Zhang, Guopeng

    2017-01-01

    Histological type is important for determining the management of patients with suspicious lung cancers. In this study, PET/CT combined with serum tumor markers were used to evaluate the histological type of lung lesions. Patients with suspicious lung cancers underwent 18F-FDG PET/CT and serum tumor markers detection. SUVmax of the tumor and serum levels of tumor markers were acquired. Differences in SUVmax and serum levels of tumor markers among different histological types of lung cancers and between EGFR mutation statues of adenocarcinoma were compared. The diagnostic efficiencies of SUVmax alone, each serum tumor marker alone, combined tumor markers and the combination of both methods were further assessed and compared. SCC had the highest level of SUVmax, followed by SCLC and adenocarcinoma, and benign lesions had a lowest level. CYFRA21-1 and SCC-Ag were significantly higher in SCC, NSE was significantly higher in SCLC (Ptumor marker or SUVmax alone. When combined, the AUC, sensitivity and specificity increased significantly (Ptumor markers (P>0.05 for all). SUVmax and serum tumor markers show values in evaluating the histological types of suspicious lung cancers. When properly combined, the diagnostic efficiency can increase significantly.

  17. Polydopamine-coated gold nanostars for CT imaging and enhanced photothermal therapy of tumors

    Science.gov (United States)

    Li, Du; Shi, Xiangyang; Jin, Dayong

    2016-12-01

    The advancement of biocompatible nanoplatforms with dual functionalities of diagnosis and therapeutics is strongly demanded in biomedicine in recent years. In this work, we report the synthesis and characterization of polydopamine (pD)-coated gold nanostars (Au NSs) for computed tomography (CT) imaging and enhanced photothermal therapy (PTT) of tumors. Au NSs were firstly formed via a seed-mediated growth method and then stabilized with thiolated polyethyleneimine (PEI-SH), followed by deposition of pD on their surface. The formed pD-coated Au NSs (Au-PEI@pD NSs) were well characterized. We show that the Au-PEI@pD NSs are able to convert the absorbed near-infrared laser light into heat, and have strong X-ray attenuation property. Due to the co-existence of Au NSs and the pD, the light to heat conversion efficiency of the NSs can be significantly enhanced. These very interesting properties allow their uses as a powerful theranostic nanoplatform for efficient CT imaging and enhanced phtotothermal therapy of cancer cells in vitro and the xenografted tumor model in vivo. With the easy functionalization nature enabled by the coated pD shell, the developed pD-coated Au NSs may be developed as a versatile nanoplatform for targeted CT imaging and PTT of different types of cancer.

  18. Cellular immune responses against CT7 (MAGE-C1) and humoral responses against other cancer-testis antigens in multiple myeloma patients.

    Science.gov (United States)

    Lendvai, Nikoletta; Gnjatic, Sacha; Ritter, Erika; Mangone, Michael; Austin, Wayne; Reyner, Karina; Jayabalan, David; Niesvizky, Ruben; Jagannath, Sundar; Bhardwaj, Nina; Chen-Kiang, Selina; Old, Lloyd J; Cho, Hearn Jay

    2010-01-29

    The type I melanoma antigen gene (MAGE) proteins CT7 (MAGE-C1) and MAGE-A3 are commonly expressed in multiple myeloma (MM), and their expression correlates with increased plasma cell proliferation and poor clinical outcome. They belong to the cancer-testis antigen (CTAg) group of tumor-associated proteins, some of which elicit spontaneous immune responses in cancer patients. CT7 and MAGE-A3 are promising antigenic targets for therapeutic tumor vaccines in myeloma; therefore, it is critical to determine if they are immunogenic in MM patients. We analyzed cellular and humoral immune responses against CTAgs in patients with plasma cell dyscrasias: MM, monoclonal gammopathy of undetermined significance (MGUS), and Waldenström's macroglobulinemia (WM). Bone marrow lymphocytes from two of four untreated MM patients exhibited CT7-specific cellular immune responses as measured by an autologous cellular immunity assay, the first such immune response to CT7 to be reported in cancer patients. Sera from 24 patients were screened by ELISA for humoral immune responses to CTAgs. Two patients with MM demonstrated positive titers, one for MAGE-A1 and the other for SSX1. These data demonstrate that CTAgs, particularly CT7, are immunogenic in MM patients and merit further exploration as targets of immunological therapy in MM.

  19. Intraarterial Chemotherapy or Chemoembolization for Locally Advanced and/or Recurrent Hepatic Tumors: Evaluation of the Feeding Artery with an Interventional CT System

    International Nuclear Information System (INIS)

    Hirai, Toshinori; Korogi, Yukunori; Ono, Ken; Maruoka, Kousei; Harada, Kazunori; Aridomi, Satoshi; Takahashi, Mutsumasa

    2001-01-01

    Purpose: To evaluate the utility of an interventional CT system for intraarterial chemotherapy or chemoembolization for locally advanced and/or recurrent hepatic tumors.Methods: Thirty-eight patients with locally advanced or recurrent hepatic tumors underwent 73 intraarterial contrast-enhanced CT (IA-CECT) examinations immediately before chemotherapy or chemoembolization. The degree of tumor vascularity on angiography and enhancement on IA-CECT was classified into three grades: no, mild, or marked vascularity. The IA-CECT grades were compared with the angiographic grades.Results: Twenty-nine (69%) of 42 examinations that were interpreted as having no or mild vascularity on angiography were classified as marked enhancement on IA-CECT. Based on IA-CECT findings, the position of the catheter was changed in 14 (19%) of 73 CT examinations. The reasons for the reposition were as follows: weak or no enhancement of the tumor (n = 11) or strong enhancement of the gallbladder wall (n = 3). The treatment strategy was changed in three patients (8%). No major complications relating to the interventional procedures were observed.Conclusions: IA-CECT is a reliable method when evaluating the perfusion of the tumor and adjacent normal tissues. The interventional CT system is useful for performing safe and effective intraarterial chemotherapy or chemoembolization in patients with locally advanced and/or recurrent hepatic tumors

  20. Renal Tumor Cryoablation Planning. The Efficiency of Simulation on Reconstructed 3D CT Scan

    Directory of Open Access Journals (Sweden)

    Ciprian Valerian LUCAN

    2010-12-01

    Full Text Available Introduction & Objective: Nephron-sparing surgical techniques risks are related to tumor relationships with adjacent anatomic structures. Complexity of the renal anatomy drives the interest to develop tools for 3D reconstruction and surgery simulation. The aim of the article was to assess the simulation on reconstructed 3D CT scan used for planning the cryoablation. Material & Method: A prospective randomized study was performed between Jan. 2007 and July 2009 on 27 patients who underwent retroperitoneoscopic T1a renal tumors cryoablation (RC. All patients were assessed preoperatively by CT scan, also used for 3D volume rendering. In the Gr.A, the patients underwent surgery planning by simulation on 3D CT scan. In the Gr.B., patients underwent standard RC. The two groups were compared in terms of surgical time, bleeding, postoperative drainage, analgesics requirement, hospital stay, time to socio-professional reintegration. Results: Fourteen patients underwent preoperative cryoablation planning (Gr.A and 13 patients underwent standard CR (Gr.B. All parameters analyzed were shorter in the Gr.A. On multivariate logistic regression, only shortens of the surgical time (138.79±5.51 min. in Gr.A. vs. 140.92±5.54 min in Gr.B. and bleeding (164.29±60.22 mL in Gr.A. vs. 215.38±100.80 mL in Gr.B. achieved statistical significance (p<0.05. The number of cryoneedles assessed by simulation had a 92.52% accuracy when compared with those effectively used. Conclusions: Simulation of the cryoablation using reconstructed 3D CT scan improves the surgical results. The application used for simulation was able to accurately assess the number of cryoneedles required for tumor ablation, their direction and approach.