WorldWideScience

Sample records for tube configuration impact

  1. The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room

    International Nuclear Information System (INIS)

    Domienik, J; Zmyślony, M; Bissinger, A

    2014-01-01

    The aim of the study was to analyse the influence of the x-ray tube configuration on the radiation doses to eye lens and extremities of cardiologists performing pacemaker implantation procedures in electrophysiology laboratory. The measurements were performed on one, widely used, portable C-arm system, first with x-ray tube mounted above the patient table and image intensifier below it and then on a reinstalled (but essentially the same) system with under-table x-ray tube configuration. Thermoluminescent dosimeters, placed in various positions near the eye lens, on the hands and ankle, were used during every procedure. The comparison of doses received by cardiologists after changing the x-ray tube configuration from over- to under-table shows statistically significant dose reduction (p < 0.009) for the eye lens closest to the x-ray tube, left finger, left wrist, while for the ankle a dose increase is observed. The corresponding over- to under-table x-ray tube median dose ratios are 4.1 for the right eye, 4.8 for the left finger, 3.0 for left wrist and, finally, 0.13 for the right ankle. Systems with under-table x-ray tube are preferable from a radiation protection point of view. The observed significant increase in doses to the legs should be partially compensated by the use of a protective lead curtain. (note)

  2. The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room.

    Science.gov (United States)

    Domienik, J; Bissinger, A; Zmyślony, M

    2014-12-01

    The aim of the study was to analyse the influence of the x-ray tube configuration on the radiation doses to eye lens and extremities of cardiologists performing pacemaker implantation procedures in electrophysiology laboratory. The measurements were performed on one, widely used, portable C-arm system, first with x-ray tube mounted above the patient table and image intensifier below it and then on a reinstalled (but essentially the same) system with under-table x-ray tube configuration. Thermoluminescent dosimeters, placed in various positions near the eye lens, on the hands and ankle, were used during every procedure. The comparison of doses received by cardiologists after changing the x-ray tube configuration from over- to under-table shows statistically significant dose reduction (p x-ray tube, left finger, left wrist, while for the ankle a dose increase is observed. The corresponding over- to under-table x-ray tube median dose ratios are 4.1 for the right eye, 4.8 for the left finger, 3.0 for left wrist and, finally, 0.13 for the right ankle. Systems with under-table x-ray tube are preferable from a radiation protection point of view. The observed significant increase in doses to the legs should be partially compensated by the use of a protective lead curtain.

  3. 'Bootstrap' Configuration for Multistage Pulse-Tube Coolers

    Science.gov (United States)

    Nguyen, Bich; Nguyen, Lauren

    2008-01-01

    A bootstrap configuration has been proposed for multistage pulse-tube coolers that, for instance, provide final-stage cooling to temperatures as low as 20 K. The bootstrap configuration supplants the conventional configuration, in which customarily the warm heat exchangers of all stages reject heat at ambient temperature. In the bootstrap configuration, the warm heat exchanger, the inertance tube, and the reservoir of each stage would be thermally anchored to the cold heat exchanger of the next warmer stage. The bootstrapped configuration is superior to the conventional setup, in some cases increasing the 20 K cooler's coefficient of performance two-fold over that of an otherwise equivalent conventional layout. The increased efficiency could translate into less power consumption, less cooler mass, and/or lower cost for a given amount of cooling.

  4. Experimental study of tube/support impact forces in multi-span PWR steam generator tubes

    International Nuclear Information System (INIS)

    Axisa, F.; Desseaux, A.; Gibert, R.J.

    1984-12-01

    The vibro-impact response of a straight part of a steam generator tube is investigated experimentally and using numerical simulation with the aim to relate tube overall dynamics with excitation and tube-support clearance. Configuration studied here corresponds to the tube being excited in only one direction at its first resonance presenting an antinode of vibration at the impacted support. Tests show namely that midspan displacement of tube is almost proportional to excitation level and clearance. Impact forces averaged over a cycle of vibration are almost proportional to excitation and poorly dependent on clearance. Results of numerical simulation are in fairly good agreement with test results

  5. Corium Configuration and Penetration Tube Failure for Fukushima Daiichi Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    An, Sang Mo; Lee, Jae Bong; Kim, Hwan Yeol; Song, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    For the LWRs (light water reactors), the penetration tubes at the reactor vessel lower head are regarded as the most vulnerable structures along with a global vessel failure during a severe accident because they can be seriously damaged by a corium melt or debris relocated into the lower plenum of the vessel. The research on the penetration tube failure is of higher importance in the BWRs, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. There are more than one hundred of penetration tubes in the Fukushima Daiichi NPPs (nuclear power plants), such as ICM-GTs (in-core monitoring guide tubes), CRGTs (control rod guide tubes) and drain tubes. The ICM-GTs include SRMs (source range monitors), IRMs (intermediate range monitors), LPRMs (local power range monitors) and TIPs (traversing in-core probes), which are much thinner than other tubes. The experimental researches to investigate the corium configuration and the penetration tube failure for the Fukushima Daiichi NPPs were introduced and some meaningful results were summarized. It was shown that the corium ingot was separated into two layers, of which the upper layer was metal-rich while the lower one was oxide-rich. It seemed that B{sub 4}C would contribute to reducing the density of the metallic melt. The two-layered configuration will provide useful information to understand the core melt progression and post-recovery actions for the Fukushima Daiichi NPPs. In addition, we performed a large scale penetration tube failure experiment for the SRM/IRM guide tube, and showed high possibilities of large amount of corium discharge out of the reactor vessel lower head, which followed by the tube melting in a very short time. We are planning to perform the penetration tube failure experiments for another dry tube of ICM-GT (LPRM guide tube), and later for the wet tube (CRGT)

  6. Plasma immersion ion implantation (and deposition) inside metallic tubes of different dimensions and configurations

    Science.gov (United States)

    Ueda, M.; Silva, C.; Santos, N. M.; Souza, G. B.

    2017-10-01

    There is a strong need for developing methods to coat or implant ions inside metallic tubes for many practical contemporary applications, both for industry and science. Therefore, stainless steel tubes with practical diameters of 4, 11 and 16 cm, but short lengths of 20 cm, were internally treated by nitrogen plasma immersion ion implantation (PIII). Different configurations as tube with lid in one of the ends or both sides open were tested for better PIII performance, in the case of smallest diameter tube. Among these PIII tests in tubes, using the 4 cm diameter one with a lid, it was possible to achieve tube temperatures of more than 700 °C in 15 min and maintain it during the whole treatment time (typically 2 h). Samples made of different materials were placed at the interior of the tube, as the monitors for posterior analysis, and the tube was solely pulsed by high voltage pulser producing high voltage glow discharge and hollow cathode discharge both driven by a moderate power source. In this experiment, samples of SS 304, pure Ti, Ti6Al4V and Si were used for the tests of the above methods. Results on the analysis of the surface of these nitrogen PIII treated materials, as well as on their processing methods, are presented and discussed in the paper.

  7. IGA resistance of TT Alloy 690 and concentration behavior of Broached Egg Crate tube support configuration

    International Nuclear Information System (INIS)

    Suzuki, S.; Kusakabe, T.; Yamamoto, H.; Arioka, K.; Ochi, T.

    1992-01-01

    In order to improve the reliability of the Steam Generator (SG), TT Alloy 690 and BEC (Broached Egg Crate) type tube support plate has been developed. Some tests are carried out to heighten the reliability for these improvements all the more and the following results are obtained. (1) SERT test (Slow Extension Rate Test) made clear that TT690 has less IGA susceptibility in comparison with MA600. (2) The alkaline susceptibility on the occurrence of IGA/SCC on TT690 and MA600 obtained by SERT corresponds to that obtained by Model Boiler test. (3) By model boiler test, superior concentration behaviors for BEC type tube support plate configuration have been recognized in comparison with Drill type. This result is obtained by the joint research of the five utilities (Kansai Epco, Hokkaido Epco, Shikoku Epco, Kyushu Epco, JAPCO) and MHI

  8. Parametric study and performance analysis of hybrid rocket motors with double-tube configuration

    Science.gov (United States)

    Yu, Nanjia; Zhao, Bo; Lorente, Arnau Pons; Wang, Jue

    2017-03-01

    The practical implementation of hybrid rocket motors has historically been hampered by the slow regression rate of the solid fuel. In recent years, the research on advanced injector designs has achieved notable results in the enhancement of the regression rate and combustion efficiency of hybrid rockets. Following this path, this work studies a new configuration called double-tube characterized by injecting the gaseous oxidizer through a head end injector and an inner tube with injector holes distributed along the motor longitudinal axis. This design has demonstrated a significant potential for improving the performance of hybrid rockets by means of a better mixing of the species achieved through a customized injection of the oxidizer. Indeed, the CFD analysis of the double-tube configuration has revealed that this design may increase the regression rate over 50% with respect to the same motor with a conventional axial showerhead injector. However, in order to fully exploit the advantages of the double-tube concept, it is necessary to acquire a deeper understanding of the influence of the different design parameters in the overall performance. In this way, a parametric study is carried out taking into account the variation of the oxidizer mass flux rate, the ratio of oxidizer mass flow rate injected through the inner tube to the total oxidizer mass flow rate, and injection angle. The data for the analysis have been gathered from a large series of three-dimensional numerical simulations that considered the changes in the design parameters. The propellant combination adopted consists of gaseous oxygen as oxidizer and high-density polyethylene as solid fuel. Furthermore, the numerical model comprises Navier-Stokes equations, k-ε turbulence model, eddy-dissipation combustion model and solid-fuel pyrolysis, which is computed through user-defined functions. This numerical model was previously validated by analyzing the computational and experimental results obtained for

  9. Reliability impact of RF tube technology for the NPB

    International Nuclear Information System (INIS)

    Bueck, J.C.

    1989-01-01

    Two reliability options, redundancy and operating margin, are examined to determine their effect on power system configurations using RF tube technology (klystron and klystrode) powered Neutral Particle Beam weapons. Redundance is addressed by providing an additional identical RF tube to the tubes required to power an accelerator RF element (DTL section, RFQ, or CCL). RF elements do not share RF power with other RF elements. Operating margin provides increased reliability by sizing the RF tubes such that tube operating levels may be increased compensate for the loss of a tube. It is shown that power system mass is affected by the choice of reliability measures, that higher power tubes coupled with higher power RF elements may mitigate mass increases, and that redundancy appears preferable to operating margin as a method of improving RF system reliability

  10. Optimizing Facility Configurations and Operating Conditions for Improved Performance in the NASA Ames 24 Inch Shock Tube

    Science.gov (United States)

    Bogdanoff, David W.; Cruden, Brett A.

    2016-01-01

    The Ames Electric Arc Shock Tube (EAST) is a shock tube wherein the driver gas can be heated by an electric arc discharge. The electrical energy is stored in a 1.2 MJ capacitor bank. Four inch and 24 inch diameter driven tubes are available. The facility is described and the need for testing in the 24 inch tube to better simulate low density NASA mission profiles is discussed. Three test entries, 53, 53B and 59, are discussed. Tests are done with air or Mars gas (95.7% CO2/2.7% N2/1.6% Ar) at pressures of 0.01 to 0.14 Torr. Velocities spanned 6.3-9.2 km/s, with a nominal center of 7 km/s. Many facility configurations are studied in an effort to improve data quality. Various driver and driven tube configurations and the use of a buffer section between the driver and the driven tube are studied. Diagnostics include test times, time histories of the shock light pulses and tilts of the shock wave off the plane normal to the tube axis. The report will detail the results of the various trials, give the best configuration/operating conditions found to date and provide recommendations for further improvements. Finally, diaphragm performance is discussed.

  11. Correlating Stiffness and Shear Lag Behavior with Brace Configuration of Tall Truss Tube Buildings

    Directory of Open Access Journals (Sweden)

    Himanshu Gaur

    2015-06-01

    Full Text Available As the height of buildings increases, effect of shear lag also becomes considerable in the design of high rise buildings. In this paper, shear lag effect in tall buildings of heights, i.e., 120, 96, 72, 48 and 36 stories of which aspect ratio ranges from 3 to 10 is studied. Tube in tube structural system with façade bracing is used for designing the building of height 120 story. It is found that bracing system considerably reduces the shear lag effect and hence increases the building stiffness to withstand lateral loads. Different geometric patterns of the bracing system are considered. The best effective geometric configuration of a bracing system is concluded in this study. Lateral force, as wind load, is applied on the buildings as it is the most dominant lateral force for such heights. Wind load is set as per Indian standard code of Practice IS 875 Part 3. For analysis purposes, the SAP2000 software program is used.

  12. Vibro-impact responses of a tube with tube--baffle interaction

    International Nuclear Information System (INIS)

    Shin, Y.S.; Sass, D.E.; Jendrzejczyk, J.A.

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments

  13. Impact of radiation dose on nuclear shuttle configuration

    Science.gov (United States)

    Goetz, C. A.; Billings, M. A.

    1972-01-01

    The impact of nuclear radiation (from the NERVA propulsion system) on the selection of a reference configuration for each of two classes of the reusable nuclear shuttle is considered. One class was characterized by a single propellant tank, the shape of whose bottom was found to have a pronounced effect on crew radiation levels and associated shield weight requirements. A trade study of shield weight versus structural weight indicated that the minimum-weight configuration for this class had a tank bottom in the shape of a frustum of a 10 deg-half-angle cone. A hybrid version of this configuration was found to affect crew radiation levels in substantially the same manner. The other class of RNS consisted of a propulsion module and eight propellant modules. Radiation analyses of various module arrangements led to a design configuration with no external shield requirements.

  14. Modelling the side impact of carbon fibre tubes

    International Nuclear Information System (INIS)

    Sudharsan, R; Rolfe, B F; Hodgson, P D

    2010-01-01

    Metallic tubes have been extensively studied for their crashworthiness as they closely resemble automotive crash rails. Recently, the demand to improve fuel economy and reduce vehicle emissions has led automobile manufacturers to explore the crash properties of light weight materials such as fibre reinforced polymer composites, metallic foams and sandwich structures in order to use them as crash barriers. This paper discusses the response of carbon fibre reinforced polymer (CFRP) tubes and their failure mechanisms during side impact. The energy absorption of CFRP tubes is compared to similar Aluminium tubes. The response of the CFRP tubes during impact was modelled using Abaqus finite element software with a composite fabric material model. The material inputs were given based on standard tension and compression test results and the in-plane damage was defined based on cyclic shear tests. The failure modes and energy absorption observed during the tests were well represented by the finite element model.

  15. Modelling the side impact of carbon fibre tubes

    Science.gov (United States)

    Sudharsan, Ms R.; Rolfe, B. F., Dr; Hodgson, P. D., Prof

    2010-06-01

    Metallic tubes have been extensively studied for their crashworthiness as they closely resemble automotive crash rails. Recently, the demand to improve fuel economy and reduce vehicle emissions has led automobile manufacturers to explore the crash properties of light weight materials such as fibre reinforced polymer composites, metallic foams and sandwich structures in order to use them as crash barriers. This paper discusses the response of carbon fibre reinforced polymer (CFRP) tubes and their failure mechanisms during side impact. The energy absorption of CFRP tubes is compared to similar Aluminium tubes. The response of the CFRP tubes during impact was modelled using Abaqus finite element software with a composite fabric material model. The material inputs were given based on standard tension and compression test results and the in-plane damage was defined based on cyclic shear tests. The failure modes and energy absorption observed during the tests were well represented by the finite element model.

  16. Effects of entrance configuration on pressure loss and heat transfer of transitional gas flow in a circular tube

    International Nuclear Information System (INIS)

    Ogawa, Masuro; Kawamura, Hiroshi

    1986-01-01

    Pressure loss and heat transfer of a transitional gas flow are affected significantly by the entrance configuration. The friction factor and the heat transfer coefficient were measured using a circular tube with four different kinds of entrance configurations. The Reynolds number at the transition from laminar to intermittent flow was varied from about 1,940 to 9,120. The intermittency factor was measured for heated and unheated flows ; and the relation between the intermittency and the friction factor or heat transfer coefficient was examined. Several existing correlations were tested and found to correlate with the experimental results fairly well. (author)

  17. Stability of interlinked neutron vortex and proton flux tube arrays in a neutron star: equilibrium configurations

    Science.gov (United States)

    Drummond, L. V.; Melatos, A.

    2017-12-01

    Three-dimensional, Gross-Pitaevskii equation (GPE) simulations are presented of the interaction between neutron superfluid vortices and proton superconductor flux tubes in a rotating, harmonic trap, representing an idealized model of the outer core of a neutron star. Low-energy states of the neutron condensate are calculated by evolving the GPE in imaginary time in the presence of a prescribed, static, rectilinear flux tube array. The calculations are carried out as a function of the angle between the global magnetic and rotation axes, and the amplitude and sign of the current-current and density couplings between the neutron and proton condensates. It is found that the system is frustrated by the competition between vortex-vortex repulsion and vortex-flux-tube attraction (pinning), leading to the formation of vortex tangles and 'glassy' behaviour characterized by multiple metastable states spaced closely in energy. The dimensionless parameters in the simulations are ordered as one expects in a neutron star, but the dynamic range is many orders of magnitude smaller than in reality, so caution must be exercised when assessing the astrophysical implications. Nevertheless, the results suggest that tangled vorticity may be endemic in neutron star outer cores.

  18. Long tube heat exchanger: the facility and some preliminary tests on the down center/up annular flow configuration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D.O.; Johnson, R.W.; Weatherbee, R.L.

    1980-03-01

    A test facility was designed and constructed to study forced flow boiling heat transfer in a closed loop long tube heat exchanger which is a two concentric-tube vertical design. The system consists of a 12 m long heat exchanger which can be operated at pressures to 689.3 kPa with pumped or natural convection flow rates from 0.0631 to 0.631 liters/second and which can be irradiated with a maximum steady heat flux rate of 50 kW/m/sup 2/ by a set of resistive heaters operable at temperatures up to 1250/sup 0/C. The facility was also designed so that other heat exchanger configurations can be tested with minimum difficulty (i.e., little or no modification of the system other than to replace the heat exchanger). The preliminary tests indicate that the system can be operated in a stable mode. This facility was motivated primarily by the magma energy research program where energy is extracted from magma by heat exchangers similar to the configuration in this report.

  19. Quasistatic analysis on configuration of two-phase flow in Y-shaped tubes

    KAUST Repository

    Zhong, Hua

    2014-12-01

    We investigate the two-phase flow in a horizontally placed Y-shaped tube with different Young\\'s angle and width in each branch. By using a quasistatic approach, we can determine the specific contact position and the equilibrium contact angle of fluid in each branch based on the minimization problem of the free energy of the system. The wettability condition and the width of the two branches play important roles in the distribution of fluid in each branch. We also consider the effect of gravity. Some fluid in the upper branch will be pulled down due to the competition of the surface energy and the gravitational energy. The result provides some insights on the theory of two-phase flow in porous media. In particular, it highlights that the inhomogeneous wettability distribution affects the direction of the fluid penetrating a given porous medium domain. It also sheds light on the current debate whether relative permeability may be considered as a full tensor rather than a scalar.

  20. Impact of spectral transition zone in reference ENIGMA configuration.

    Energy Technology Data Exchange (ETDEWEB)

    Aliberti, G.; Palmiotti, G.; Taiwo, T. A.; Tommasi, J.

    2005-10-05

    Neutron Investigation of Gas-cooled reactor at Masurca) is being planned for Cadarache. This new experiment would provide better understanding of GFR neutronic features and will be the basis for the extension of current neutronics code validation domain (particularly, the ERANOS code system in France) to the analysis of GFRs. Experimental planning and decisions are ongoing for ENIGMA. One of the items that have been evaluated is the feasibility of obtaining different flux spectra in the ENIGMA reference configuration, giving the flexibility of simulating a large series of proposed gas-cooled fast systems with harder or softer spectra. In order to achieve this goal it was proposed to use a spectral transition zone in the center region of the ENIGMA core configuration. Another goal of the study is to evaluate the impact of the graphite cross-sections on the performance characteristics of the MASURCA configurations. The work was supported by ANL, through the residence of one of the authors at CEA-Cadarache in 2005. In this report, the impacts of the transition zone on the core physics parameters of the reference ENIGMA configuration are summarized.

  1. Impacts of configuration losses on active magnetic regenerator device performance

    International Nuclear Information System (INIS)

    Niknia, I.; Campbell, O.; Christiaanse, T.V.; Govindappa, P.; Teyber, R.; Trevizoli, P.V.; Rowe, A.

    2016-01-01

    Highlights: • A sinusoidal mesh is more effective than uniform mesh. • A simple resistance network model can simulate external losses with good accuracy. • External heat leaks significantly impact performance at higher temperature spans. • Mass-flow weighted fields (step change model) can be used instead of full waveform. • Efficiency can exceed 70% for low net loads. - Abstract: A one dimensional, time dependent model is used to study the performance of an active magnetic regenerator. Parameters related to device configuration such as external heat leaks and demagnetization effects are included. Performance is quantified in terms of cooling power and second law efficiency for a range of displaced fluid volumes and operating frequencies. A sinusoidal meshing technique is employed and the model is validated against experimental measurements using gadolinium spheres. For the cases studied, sinusoidal mesh reduced the simulation time up to 70% compared to uniform meshing technique. Simulation results show that step change model for applied field can be effectively used instead of full field wave form if the flow weighted average low and high field values are used. It is found that external losses have a significant impact on measured AMR performance. Calculating the maximum temperature span of a typical system without considering the loss mechanisms external to the regenerator can overestimate actual performance.

  2. Impact of error fields on equilibrium configurations in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Barbato, Lucio [DIEI, Università di Cassino and Lazio Meridionale, Cassino (Italy); Formisano, Alessandro, E-mail: alessandro.formisano@unina2.it [Department of Industrial and Information Engineering, Seconda Univ. di Napoli, Aversa (Italy); Martone, Raffaele [Department of Industrial and Information Engineering, Seconda Univ. di Napoli, Aversa (Italy); Villone, Fabio [DIEI, Università di Cassino and Lazio Meridionale, Cassino (Italy)

    2015-10-15

    Highlights: • Error fields (EF) are discrepancies from nominal magnetic field, and may alter plasma behaviour. • They are due to, e.g., coils manufacturing and assembly errors. • EF impact in ITER equilibria is analyzed using numerical simulations. • A high accuracy 3D field computation module and a Grad-Shafranov solver are used. • Deformations size allow using a linearized model, and performing a sensitivity analysis. - Abstract: Discrepancies between design and actual magnetic field maps in tokamaks are unavoidable, and are associated to a number of causes, e.g. manufacturing and assembly tolerances on magnets, presence of feeders and joints, non-symmetric iron parts. Such error fields may drive plasma to loss of stability, and must be carefully controlled using suitable correction coils. Anyway, even when kept below safety threshold, error fields may alter the behavior of plasma. The present paper, using as example the error fields induced by tolerances in toroidal field coils, quantifies their effect on the plasma boundary shape in equilibrium configurations. In particular, a procedure able to compute the shape perturbations due to given deformations of the coils has been set up and used to carry out a thorough statistical analysis of the error field-shape perturbations relationship.

  3. Computation of impact-friction interaction between a vibrating tube and its loose supports

    International Nuclear Information System (INIS)

    Jacquart, G.; Gay, N.

    1993-01-01

    Maintaining PWR components in reliable operating condition requires complex design to prevent various damaging processes including flow-induced vibration and wear mechanisms. To improve prediction of tube/support interaction and wear in PWR components, EDF has undertaken a comprehensive program involving both calculations and experiments. This paper describes EDF numerical development with the Aster mechanics computer code to calculate the non-linear dynamics of tubular structures with loose supports. Both numerical and experimental validations of this computer code are given. The numerical technique for dynamic simulation is based on a Ritz decomposition method, including the modal superposition method as used in some other computer codes. The explicit expression of impact and friction forces allows a fast, explicit integration scheme to be used. Different projection bases are compared. Some can improve significantly the resolution of the dynamic problem. The code numerical validations consist in simulations of some mechanical configurations (analytical or computed) provided in the literature. The comparison of the Aster calculation results with the available data of the literature shows the high accuracy of the computer code. A validation on some experimental data is also provided. The experiment used for this validation consists in a multi-supported U-tube, with four loose supports in the U-bend and submitted to harmonic and broad band excitation forces. Three of them correspond to a small gap G s , and the fourth one to a large gap G 1 (G 1 = 15 G s ). In this experiment, the excitation forces are varied. For each configuration, the tube response is computed and compared to the experimental results. The analysis of the parameters governing wear concludes to a good accordance between the calculated and measured values. (authors). 13 figs., 4 tabs., 10 refs

  4. Research on liquid impact forming technology of double-layered tubes

    Science.gov (United States)

    Sun, Changying; Liu, Jianwei; Yao, Xinqi; Huang, Beixing; Li, Yuhan

    2018-03-01

    A double-layered tube is widely used and developed in various fields because of its perfect comprehensive performance and design. With the advent of the era of a double-layered tube, the requirements for double layered tube forming quality, manufacturing cost and forming efficiency are getting higher, so forming methods of a double-layered tube are emerged in an endless stream, the forming methods of a double-layered tube have a great potential in the future. The liquid impact forming technology is a combination of stamping technology and hydroforming technology. Forming a double-layered tube has huge advantages in production cost, quality and efficiency.

  5. Crush analysis of the foam-filled bitubal circular tube under oblique impact

    Science.gov (United States)

    Djamaluddin, F.; Abdullah, S.; Arrifin, A. K.; Nopiah, Z. M.

    2018-02-01

    This paper presents crashworthiness analysis of bitubal cylindrical tubes under different impact angular. The numerical solution of double cylindrical tubes are determined by finite element analysis (FEA). Moreover, the structure was impacted by mass block as impactor respect to longitudinal direction of the tubes. The model of structure was developed by non-linear ABAQUS sofware with variations of load angle and dimensions of tube. The outcome of this study is the respons parameters such as the peak crusing force (PCF), energy absorption (EA) and specific energy absorption (SEA), thus it can be expected this tube as the great energy absorber.

  6. Impact of three window configurations on daylight conditions

    DEFF Research Database (Denmark)

    Dubois, Marie-Claude; Sørensen, Karl Grau; Traberg-Borup, Steen

    The report describes the results of a pilot study on daylight conditions in simple rooms of residential buildings. As a tool for the analyses the Radiance Lighting Simulating System was used to simulate one room with three different window configurations, a vertical window, a dormer window......, and a roof window. The simulations were performed for overcast sky conditions and under one sunny sky, for two different times of the day. The study shows that the window configuration affects the daylight conditions (distribution and intensity) significantly. The roof window results in a higher (average......) daylight factor on a horizontal plane, i.e. more than twice as high compared with the vertical window, and more than triple as high compared with the dormer window....

  7. Neutron noise to detect BWR-4 in-core instrument tube vibrations and impacting

    International Nuclear Information System (INIS)

    Fry, D.N.; Kryter, R.C.; Mathis, M.V.; Mott, J.E.; Robinson, J.C.

    1979-01-01

    Noise analysis was used to investigate in-core instrument tube vibrations in boiling water reactor-4 (BWR-4)-type reactors. Neutron noise signals from in-core fission chambers and acoustic noise signals from externally mounted accelerometers were used in these studies. The results show that neutron noise can be used to detect vibration and, more important, impacting of instrument tubes against adjacent fuel channel boxes. Externally mounted accelerometers detect impacting but not rubbing of instrument tubes against fuel channel boxes. Accelerometers can monitor impacting only on the particular instrument tube where the accelerometer is mounted. Surveillance for instrument tube impacts can be accomplished using standard BWR-4 in-core power range neutron flux detectors at all instrument tube locations containing these detectors. Ex-vessel accelerometers can then be used to monitor instrument tubes that lack power range neutron flux detectors. However, noise on axial flux profiles obtained with movable in-core detectors is not a reliable indicator of impacting because the recorder used to plot the flux profiles does not respond adequately to the noise frequency generated by impacting. Neutron noise signatures show that modification of the bypass cooling by plugging preexisting holes and drilling new holes in the fuel assembly lower tie plate greatly reduces instrument tube vibration and eliminates impacting of instrument tubes against fuel boxes

  8. Cost optimization of biofuel production – The impact of scale, integration, transport and supply chain configurations

    NARCIS (Netherlands)

    de Jong, S.A.; Hoefnagels, E.T.A.; Wetterlund, Elisabeth; Pettersson, Karin; Faaij, André; Junginger, H.M.

    2017-01-01

    This study uses a geographically-explicit cost optimization model to analyze the impact of and interrelation between four cost reduction strategies for biofuel production: economies of scale, intermodal transport, integration with existing industries, and distributed supply chain configurations

  9. Thermoelectric System in Different Thermal and Electrical Configurations: Its Impact in the Figure of Merit

    Directory of Open Access Journals (Sweden)

    Alexander Vargas-Almeida

    2013-05-01

    Full Text Available In this work, we analyze different configurations of a thermoelectric system (TES composed of three thermoelectric generators (TEGs. We present the following considerations: (a TES thermally and electrically connected in series (SC; (b TES thermally and electrically connected in parallel (PSC; and (c parallel thermally and series electrical connection (SSC. We assume that the parameters of the TEGs are temperature-independent. The systems are characterized by three parameters, as it has been showed in recent investigations, namely, its internal electrical resistance, R, thermal conductance under open electrical circuit condition, K, and Seebeck coefficient α. We derive the equivalent parameters for each of the configurations considered here and calculate the Figure of Merit Z for the equivalent system. We show the impact of the configuration of the system on Z, and we suggest optimum configuration. In order to justify the effectiveness of the equivalent Figure of Merit, the corresponding efficiency has been calculated for each configuration.

  10. An experimental study on the impact collapse characteristics of CF/Epoxy circular tubes

    International Nuclear Information System (INIS)

    Kim, Y.N.; Im, K.H.; Park, J.W.; Yang, I.Y.

    2003-01-01

    This study is to investigate the energy absorption characteristics of CF/Epoxy (Carbon-Fiber/Epoxy Resin) circular tubes in static and impact tests. The experimental results varied significantly as a function of interlaminar number, orientation angle of outer and trigger. When a CFRP composite tube is crushed, static/impact energy is consumed by friction between the loading plate and the splayed fronds of the tube, by fracture of the fibers, matrix and their interface, and the response is complex and depends on the interaction among the different mechanisms, such as transverse shearing, laminar bending and local buckling. The collapse mode depended upon orientation angle of outer of CFRP tubes and loading status(static/impact). Typical collapse modes of CFRP tubes are wedge collapse mode, splaying collapse mode and fragmentation collapse mode

  11. Qualitative Network Analysis Tools for the Configurative Articulation of Cultural Value and Impact from Research

    Science.gov (United States)

    Oancea, Alis; Florez Petour, Teresa; Atkinson, Jeanette

    2017-01-01

    This article introduces a methodological approach for articulating and communicating the impact and value of research: qualitative network analysis using collaborative configuration tracing and visualization. The approach was proposed initially in Oancea ("Interpretations and Practices of Research Impact across the Range of Disciplines…

  12. Impact of the fouling mechanism on enzymatic depolymerization of xylan in different configurations of membrane reactors

    DEFF Research Database (Denmark)

    Mohd Sueb, Mohd Shafiq Bin; Luo, Jianquan; Meyer, Anne S.

    2017-01-01

    In order to maximize enzymatic xylan depolymerization while simultaneously purifying the resulting monosaccharide (xylose), different ultrafiltration (UF) membrane reactor configurations were evaluated. Initial results showed that the two hydrolytic enzymes required for complete depolymerization......) and the simultaneous reaction-filtration with both enzymes, respectively. This study thus confirmed that the reactor configuration has a crucial impact on the performance of both the reaction and the separation process of xylose during enzymatic xylan degradation, and that the type of fouling mechanism varies...

  13. The impact of applying product-modelling techniques in configurator projects

    DEFF Research Database (Denmark)

    Hvam, Lars; Kristjansdottir, Katrin; Shafiee, Sara

    2018-01-01

    This paper aims to increase understanding of the impact of using product-modelling techniques to structure and formalise knowledge in configurator projects. Companies that provide customised products increasingly apply configurators in support of sales and design activities, reaping benefits...... though extant literature has shown the importance of formal modelling techniques, the impact of utilising these techniques remains relatively unknown. Therefore, this article studies three main areas: (1) the impact of using modelling techniques based on Unified Modelling Language (UML), in which...... ability to reduce the number of product variants. This paper contributes to an increased understanding of what companies can gain from using more formalised modelling techniques in configurator projects, and under what circumstances they should be used....

  14. CRITICAL CONFIGURATION FOR BERYLLIUM REFLECTED ASSEMBLIES OF U(93.15)O2 FUEL RODS (1.506-CM PITCH AND 7-TUBE CLUSTERS)

    Energy Technology Data Exchange (ETDEWEB)

    Margaret A. Marshall

    2012-05-01

    A series of critical experiments were completed in 1962-1965 at Oak Ridge National Laboratory’s Critical Experiments Facility in support of the Medium-Power Reactor Experiments (MPRE) program. In the late 1950’s efforts were made to study “power plants for the production of electrical power in space vehicles”. The MPRE program was a part of those efforts and studied the feasibility of a stainless steel system, boiling potassium 1 MW(t), or about 140 kW(e), reactor. The program was carried out in [fiscal years] 1964, 1965, and 1966. A summary of the program’s effort was compiled in 1967. The delayed critical experiments were a mockup of a small, potassium-cooled space power reactor for validation of reactor calculations and reactor physics methods. Initial experiments, performed in November and December of 1962, consisted of a core of 253 unmoderated stainless steel tubes, each containing 26 UO2 fuel pellets, surrounded by a graphite reflector. Measurements were made to determine critical reflector arrangements, fission-rate distributions, and cadmium ratio distributions. “The [assemblies were built] on [a] vertical assembly machine so that the movable part was the core and bottom reflector.” The first two experiments in the series were evaluated in HEU-COMP-FAST-001 (SCCA-FUND-EXP-001) and HEU-COMP-FAST-002 (SCCA-FUND-EXP-002). The first experiment had the 253 fuel tubes packed tightly into a 22.87 cm outside diameter (OD) core tank (References 1 and 2). The second experiment in the series, performed in early 1963, had the 253 fuel tubes at a 1.506-cm triangular lattice in a 25.96 cm OD core tank and graphite reflectors on all sides. The third set of experiments in the series, performed in mid-1963, which is studied in this evaluation, used beryllium reflectors. The beryllium reflected system was the preferred reactor configuration for this application because of the small thickness of the reflector. The two core configurations had the 253 fuel tubes

  15. The Impact of Tympanostomy Tubes on Speech and Language Development in Children with Cleft Palate.

    Science.gov (United States)

    Shaffer, Amber D; Ford, Matthew D; Choi, Sukgi S; Jabbour, Noel

    2017-09-01

    Objective Describe the impact of hearing loss, tympanostomy tube placement before palatoplasty, and number of tubes received on speech outcomes in children with cleft palate. Study Design Case series with chart review. Setting Tertiary care children's hospital. Subjects and Methods Records from 737 children born between April 2005 and April 2015 who underwent palatoplasty at a tertiary children's hospital were reviewed. Exclusion criteria were cleft repair at an outside hospital, intact secondary palate, absence of postpalatoplasty speech evaluation, sensorineural or mixed hearing loss, no tubes, first tubes after palatoplasty, or first clinic after 12 months of age. Data from 152 patients with isolated cleft palate and 166 patients with cleft lip and palate were analyzed using Wilcoxon rank-sum, χ 2 , and Fisher exact test and logistic regression. Results Most patients (242, 76.1%) received tubes before palatoplasty. Hearing loss after tubes, but not before, was associated with speech/language delays at 24 months ( P = .005) and language delays ( P = .048) and speech sound production disorders (SSPDs, P = .040) at 5 years. Receiving tubes before palatoplasty was associated with failed newborn hearing screen ( P = .001) and younger age at first posttubes type B tympanogram with normal canal volume ( P = .015). Hearing loss after tubes ( P = .021), language delays ( P = .025), SSPDs ( P = .003), and velopharyngeal insufficiency ( P = .032) at 5 years and speech surgery ( P = .022) were associated with more tubes. Conclusion Continued middle ear disease, reflected by hearing loss and multiple tubes, may impair speech and language development. Inserting tubes before palatoplasty did not mitigate these impairments better than later tube placement.

  16. Impact of chest tube clearance on postoperative morbidity after thoracotomy: results of a prospective, randomised trial.

    Science.gov (United States)

    Dango, Sebastian; Sienel, Wulf; Passlick, Bernward; Stremmel, Christian

    2010-01-01

    In many centres of thoracic surgery, milking of chest tubes is performed to prevent them from blocking. The usefulness of chest tube clearance is discussed controversially. Therefore, we investigated the impact of postoperative chest tube milking on postoperative outcome in a prospective, randomised trial. Within a period of 11 months, 145 patients undergoing pulmonary resection through thoracotomy were included in the study. Two chest tubes each (silicone drainage, Redax, Mirandola, Italy) were placed in all patients (ventral tube 21Ch and dorsal tube 24Ch). Milking was applied to both chest tubes for 1 min every 2h within the first 48 h postoperatively and continuous suction of -20 cm H(2)O was maintained for 48 h. Duration of chest tube drainage, quantity and quality of effusion or air leakage, co-morbidity, length of hospital stay and 30-day postoperative morbidity and mortality were analysed. Furthermore, outcome was measured by assessment of chest radiographs at the time of discharge from hospital. Randomisation resulted in milking of chest tubes of 73 patients and in observation of chest tubes without any manipulation in 72 patients. Twenty-one patients had to be excluded from further analysis due to violation from the study protocol (n=9), necessity of replacement of a chest tubes (n=9) and re-operation for bleeding (n=3). The 30-day mortality rate was 1.4% in each group and the 30-day morbidity was 49.3% in the milking group and 52.8% in the observation group. Milking of chest tubes was not associated with a lower postoperative mortality or morbidity (p=0.99 and p=0.67, respectively; chi-square test). We observed a significant increase of postoperative pleural effusion drainage in the milking group 48 h after surgery (p=0.004; unpaired t-test). No correlation was seen between milking of chest tubes and the duration of chest tube drainage, quality of effusion, air leakage or length of hospitalisation. We showed for the first time that postoperative chest

  17. The relative impact of sizing errors on steam generator tube failure probability

    International Nuclear Information System (INIS)

    Cizelj, L.; Dvorsek, T.

    1998-01-01

    The Outside Diameter Stress Corrosion Cracking (ODSCC) at tube support plates is currently the major degradation mechanism affecting the steam generator tubes made of Inconel 600. This caused development and licensing of degradation specific maintenance approaches, which addressed two main failure modes of the degraded piping: tube rupture; and excessive leakage through degraded tubes. A methodology aiming at assessing the efficiency of a given set of possible maintenance approaches has already been proposed by the authors. It pointed out better performance of the degradation specific over generic approaches in (1) lower probability of single and multiple steam generator tube rupture (SGTR), (2) lower estimated accidental leak rates and (3) less tubes plugged. A sensitivity analysis was also performed pointing out the relative contributions of uncertain input parameters to the tube rupture probabilities. The dominant contribution was assigned to the uncertainties inherent to the regression models used to correlate the defect size and tube burst pressure. The uncertainties, which can be estimated from the in-service inspections, are further analysed in this paper. The defect growth was found to have significant and to some extent unrealistic impact on the probability of single tube rupture. Since the defect growth estimates were based on the past inspection records they strongly depend on the sizing errors. Therefore, an attempt was made to filter out the sizing errors and to arrive at more realistic estimates of the defect growth. The impact of different assumptions regarding sizing errors on the tube rupture probability was studied using a realistic numerical example. The data used is obtained from a series of inspection results from Krsko NPP with 2 Westinghouse D-4 steam generators. The results obtained are considered useful in safety assessment and maintenance of affected steam generators. (author)

  18. Effect of Loop Configuration on Steam Drum Level Control for a Multiple Drum Interconnected Loops Pressure Tube Type Boiling Water Reactor

    Science.gov (United States)

    Gaikwad, Avinash J.; Vijayan, P. K.; Iyer, Kannan; Bhartiya, Sharad; Kumar, Rajesh; Lele, H. G.; Ghosh, A. K.; Kushwaha, H. S.; Sinha, R. K.

    2009-12-01

    For AHWR (Advanced Heavy Water Reactor), a pressure tube type Boiling Water Reactor (BWR) with parallel inter-connected loops, the Steam Drum (SD) level control is closely related to Main Heat Transport (MHT) coolant inventory and sustained heat removal through natural circulation, hence overall safety of the power plant. The MHT configuration with multiple (four) interconnected loops influences the SD level control in a manner which has not been previously addressed. The MHT configuration has been chosen based on comprehensive overall design requirements and certain Postulated Initiated Event (PIEs) for Loss of Coolant Accident (LOCA), which postulates a double ended break in the four partitioned Emergency Core Cooling System (ECCS) header. A conventional individual three-element SD level controller can not account for the highly coupled and interacting behaviors, of the four SD levels. An innovative three-element SD level control scheme is proposed to overcome this situation. The response obtained for a variety of unsymmetrical disturbances shows that the SD levels do not diverge and quickly settle to the various new set points assigned. The proposed scheme also leads to enhanced safety margins for most of the PIEs considered with a little influence on the 100% full power steady-state design conditions.

  19. Accuracy of panoramic, panoramic with palpation and tube shift technique to localize maxillary impacted cuspid

    Directory of Open Access Journals (Sweden)

    GoodarziPour D.

    2009-12-01

    Full Text Available "nBackground and Aim: Impaction of maxillary cuspids is the most common after third molars with 1% to 3% prevalence. Localization of these impacted teeth may affect orthodontic or surgical treatment plan. Therefore, different techniques have been introduced to localize impacted canines. The present study was conducted to compare the accuracy of panoramic, tube shift and panoramic plus palpation in determination of the position of maxillary impacted canine."nMaterials and Methods: 47 patients (20 females, 27 males with the age of more than 12 years (mean age of 25.4 years old whom referred to Dental School, Tehran University of Medical Sciences, with at least one impacted maxillary canine included. An oral and maxillofacial radiologist localized impacted canine first by using panoramic then tube shift technique blindly. After that, an oral and maxillofacial surgeon localized the canine by panoramic and palpation of the area before surgery. Data obtained from radiologist and surgeon were compared with true location of canine after surgery. Statistical analysis was done using sensitivity and specificity."nResults: Among total 47 impacted maxillary canines, 11 cases (23.4% showed buccal impactions and 36 cases (76.6% palatal impactions. Sensitivity (ability of technique to localize palatal impaction of all of the techniques were same (100% but specificity (ability of technique to localize buccal impaction of tube shift (100% was more than two others (0%."nConclusion: The tube shift technique was the most accurate technique to localize maxillary unerupted canines compared to the others. Due to the ability of panoramic and panoramic with palpation in prediction of palatal canine impactions and failure of these techniques to predict buccal impactions, both methods are not suitable in localization of impacted maxillary canines and they must be used as adjunctive techniques.

  20. Management of environmental aspects as well as impacts in a company of tubes, sized tubes and conicals

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Batista de Sousa

    2007-10-01

    Full Text Available This article aims to describe the application of the Management Method of Environment Impacts and Aspects - MMEIA( GAIA - in a industrial company of medium size. The research is charactarized as exploratory, with a qualitative approach as well as quantitative that is done by a case in a industry that makes tubes, small tubes and conicals paper and sized paper. The data were colected by visits to industry, with the verification of its produtive process, research and documents analysis, interviews non structured with the managers and workers of the company as well as a questionnaire application referent to MMEIA (GAIA method aspects. The results of this mthod application are satisfactory about the observed aspects, although the company presents some questions that still can be improved in its produtice process. One can conclude the at the end of this study the organization started the people sensibilization as well as to the processes improvement, searching ways of developing its activiteies focalized on the environmental development and on the sustentability.

  1. Impact Fretting Wear Behavior of Alloy 690 Tubes in Dry and Deionized Water Conditions

    Science.gov (United States)

    Cai, Zhen-Bing; Peng, Jin-Fang; Qian, Hao; Tang, Li-Chen; Zhu, Min-Hao

    2017-07-01

    The impact fretting wear has largely occurred at nuclear power device induced by the flow-induced vibration, and it will take potential hazards to the service of the equipment. However, the present study focuses on the tangential fretting wear of alloy 690 tubes. Research on impact fretting wear of alloy 690 tubes is limited and the related research is imminent. Therefore, impact fretting wear behavior of alloy 690 tubes against 304 stainless steels is investigated. Deionized water is used to simulate the flow environment of the equipment, and the dry environment is used for comparison. Varied analytical techniques are employed to characterize the wear and tribochemical behavior during impact fretting wear. Characterization results indicate that cracks occur at high impact load in both water and dry equipment; however, the water as a medium can significantly delay the cracking time. The crack propagation behavior shows a jagged shape in the water, but crack extended disorderly in dry equipment because the water changed the stress distribution and retarded the friction heat during the wear process. The SEM and XPS analysis shows that the main failure mechanisms of the tube under impact fretting are fatigue wear and friction oxidation. The effect of medium(water) on fretting wear is revealed, which plays a potential and promising role in the service of nuclear power device and other flow equipments.

  2. An investigation on impacts of scheduling configurations on Mississippi biology subject area testing

    Science.gov (United States)

    Marchette, Frances Lenora

    The purpose of this mixed modal study was to compare the results of Biology Subject Area mean scores of students on a 4 x 4 block schedule, A/B block schedule, and traditional year-long schedule for 1A to 5A size schools. This study also reviewed the data to determine if minority or gender issues might influence the test results. Interviews with administrators and teachers were conducted about the type of schedule configuration they use and the influence that the schedule has on student academic performance on the Biology Subject Area Test. Additionally, this research further explored whether schedule configurations allow sufficient time for students to construct knowledge. This study is important to schools, teachers, and administrators because it can assist them in considering the impacts that different types of class schedules have on student performance and if ethnic or gender issues are influencing testing results. This study used the causal-comparative method for the quantitative portion of the study and constant comparative method for the qualitative portion to explore the relationship of school schedules on student academic achievement on the Mississippi Biology Subject Area Test. The aggregate means of selected student scores indicate that the Mississippi Biology Subject Area Test as a measure of student performance reveals no significant difference on student achievement for the three school schedule configurations. The data were adjusted for initial differences of gender, minority, and school size on the three schedule configurations. The results suggest that schools may employ various schedule configurations and expect student performance on the Mississippi Biology Subject Area Test to be unaffected. However, many areas of concern were identified in the interviews that might impact on school learning environments. These concerns relate to effective classroom management, the active involvement of students in learning, the adequacy of teacher education

  3. Impact on cost accuracy and profitability from implementing product configuration system – A case-study

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Hvam, Lars

    2015-01-01

    . As the literature describes, there are various benefits from implementing a PCS, however the effects on the company’s profitability have not been discussed in details. This study analyzes the impact from implementing a PCS on the accuracy of calculations in the quotations and the impact on the relative contribution...... ratios. For that reason, a configure-to-order (CTO) manufacturing company has been investigated. A longitudinal study is performed where both the accuracy of the cost calculations and the profitability is analyzed before and after implementation of a PCS. The comparison reveals increased profitability...

  4. Impact of screw configuration on the particle size distribution of granules produced by twin screw granulation.

    Science.gov (United States)

    Vercruysse, J; Burggraeve, A; Fonteyne, M; Cappuyns, P; Delaet, U; Van Assche, I; De Beer, T; Remon, J P; Vervaet, C

    2015-02-01

    Twin screw granulation (TSG) has been reported by different research groups as an attractive technology for continuous wet granulation. However, in contrast to fluidized bed granulation, granules produced via this technique typically have a wide and multimodal particle size distribution (PSD), resulting in suboptimal flow properties. The aim of the current study was to evaluate the impact of granulator screw configuration on the PSD of granules produced by TSG. Experiments were performed using a 25 mm co-rotating twin screw granulator, being part of the ConsiGma™-25 system (a fully continuous from-powder-to-tablet manufacturing line from GEA Pharma Systems). Besides the screw elements conventionally used for TSG (conveying and kneading elements), alternative designs of screw elements (tooth-mixing-elements (TME), screw mixing elements (SME) and cutters) were investigated using an α-lactose monohydrate formulation granulated with distilled water. Granulation with only conveying elements resulted in wide and multimodal PSD. Using kneading elements, the width of the PSD could be partially narrowed and the liquid distribution was more homogeneous. However, still a significant fraction of oversized agglomerates was obtained. Implementing additional kneading elements or cutters in the final section of the screw configuration was not beneficial. Furthermore, granulation with only TME or SME had limited impact on the width of the PSD. Promising results were obtained by combining kneading elements with SME, as for these configurations the PSD was narrower and shifted to the size fractions suitable for tableting. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Impact of Blanket Configuration on the Design of a Fusion-Driven Transmutation Reactor

    Directory of Open Access Journals (Sweden)

    Bong Guen Hong

    2018-02-01

    Full Text Available A configuration of a fusion-driven transmutation reactor with a low aspect ratio tokamak-type neutron source was determined in a self-consistent manner by using coupled analysis of tokamak systems and neutron transport. We investigated the impact of blanket configuration on the characteristics of a fusion-driven transmutation reactor. It was shown that by merging the TRU burning blanket and tritium breeding blanket, which uses PbLi as the tritium breeding material and as coolant, effective transmutation is possible. The TRU transmutation capability can be improved with a reduced blanket thickness, and fast fluence at the first wall can be reduced.  Article History: Received: July 10th 2017; Received: Dec 17th 2017; Accepted: February 2nd 2018; Available online How to Cite This Article: Hong, B.G. (2018 Impact of Blanket Configuration on the Design of a Fusion-Driven Transmutation Reactor. International Journal of Renewable Energy Development, 7(1, 65-70. https://doi.org/10.14710/ijred.7.1.65-70

  6. Experiments on vibro-impact dynamics of loosely supported tubes under harmonic excitation

    International Nuclear Information System (INIS)

    Axisa, F.; Izquierdo, P.

    1992-01-01

    Computational methods have been recently developed by the authors and others to predict the working life or the acceptable vibration limit of tubular structures experiencing fretting-wear caused by impact-sliding interaction with loose supports or adjacent structures. This problem is of practical interest in various nuclear and other industrial components. This paper reports an experimental work intended to validate the numerical techniques used to compute the tube non-linear vibration in presence of impact-sliding interaction. Attention is especially focused on the local and time averaged dynamical parameters governing the rate of fretting-wear. The experiments were carried out on a straight tube excited harmonically by a pair of electromagnetic shakers. The tube motion was limited by a loose support situated at about midspan. On the other hand, numerical simulations of the tests were also performed. Comparison between test and computational data resulted in rather satisfactory agreement, based on the averaged impact forces and the wear work rate. Results are also discussed in terms of detailed time histories of tube displacement and impact forces

  7. Risk impact of planned maintenance configuration at South Texas Project Electric Generating Station

    International Nuclear Information System (INIS)

    Loh, W.T.; Fleming, K.N.; Grantom, C.R.

    2004-01-01

    This paper is based on a study done for the Houston Lighting and Power Company. The purpose of this study is to estimate the risk impact of planned maintenance configurations at South Texas Project Electric Generating Station (STPEGS). To date, the focus of the STP probabilistic safety assessment (PSA) program has been to analyze risk in terms of estimates of accident frequencies that are expressed on a time-averaged basis. Thus, estimates of quantities such as severe core damage frequency have been made such that the temporal variations of this frequency with changing plant configurations are averaged out over time. The only condition that has been imposed on these estimates is that the plant is initially operating at full power when potential initiating events might occur. (author)

  8. Landscape configuration is the primary driver of impacts on water quality associated with agricultural expansion

    Science.gov (United States)

    Chaplin-Kramer, Rebecca; Hamel, Perrine; Sharp, Richard; Kowal, Virgina; Wolny, Stacie; Sim, Sarah; Mueller, Carina

    2016-07-01

    Corporations and other multinational institutions are increasingly looking to evaluate their innovation and procurement decisions over a range of environmental criteria, including impacts on ecosystem services according to the spatial configuration of activities on the landscape. We have developed a spatially explicit approach and modeled a hypothetical corporate supply chain decision representing contrasting patterns of land-use change in four regions of the globe. This illustrates the effect of introducing spatial considerations in the analysis of ecosystem services, specifically sediment retention. We explored a wide variety of contexts (Iowa, USA; Mato Grosso, Brazil; and Jiangxi and Heilongjiang in China) and these show that per-area representation of impacts based on the physical characterization of a region can be misleading. We found two- to five-fold differences in sediment export for the same amount of habitat conversion within regions characterized by similar physical traits. These differences were mainly determined by the distance between land use changes and streams. The influence of landscape configuration is so dramatic that it can override wide variation in erosion potential driven by physical factors like soil type, slope, and climate. To minimize damage to spatially-dependent ecosystem services like water purification, sustainable sourcing strategies should not assume a direct correlation between impact and area but rather allow for possible nonlinearity in impacts, especially in regions with little remaining habitat and highly variable hydrological connectivity.

  9. CRITICAL CONFIGURATION AND PHYSICS MEASUREMENTS FOR BERYLLIUM REFLECTED ASSEMBLIES OF U(93.15)O2 FUEL RODS (1.506-CM PITCH AND 7-TUBE CLUSTERS)

    Energy Technology Data Exchange (ETDEWEB)

    Margaret A. Marshall

    2014-03-01

    Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one Na

  10. Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Murphy, Michael F. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mihalczo, John T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one Na

  11. Incompatible pollen tubes in the plum style and their impact on fertilization success

    Directory of Open Access Journals (Sweden)

    Đorđević Milena

    2014-01-01

    Full Text Available The pistils of plum (Prunus domestica L. cv. ‘Čačanska Lepotica’ were self- and cross-pollinated in order to investigate occurrence of incompatible pollen tubes in the style, and their impact on fertilization success. The investigation also included open pollination variant. The highest percentage of these stopped the growth in the upper third of the style. Under cross-pollination variant, 15.4% and 12.1% of pollen tubes observed in the upper part of the style in the first and the second years of study, respectively, were found incompatible. In view of the above parameters, in the self- pollination variant, 15.0% and 17.0% of pollen tubes were found incompatible by years. As for the open pollination, percentages of incompatible pollen tubes in the upper part of the style by years were 14.0% and 14.4%, respectively. The occurrence of incompatible pollen tubes did not influence the fertilization success in these pollination variants. [Projekat Ministarstva nauke Republike Srbije, br. TR31064-Development and preservation of genetic potential of temperate zone fruits

  12. The impact of subgroup type and subgroup configurational properties on work team performance.

    Science.gov (United States)

    Carton, Andrew M; Cummings, Jonathon N

    2013-09-01

    Scholars have invoked subgroups in a number of theories related to teams, yet certain tensions in the literature remain unresolved. In this article, we address 2 of these tensions, both relating to how subgroups are configured in work teams: (a) whether teams perform better with a greater number of subgroups and (b) whether teams perform better when they have imbalanced subgroups (majorities and minorities are present) or balanced subgroups (subgroups are of equal size). We predict that the impact of the number and balance of subgroups depends on the type of subgroup-whether subgroups are formed according to social identity (i.e., identity-based subgroups) or information processing (i.e., knowledge-based subgroups). We first propose that teams are more adversely affected by 2 identity-based subgroups than by any other number, yet the uniquely negative impact of a 2-subgroup configuration is not apparent for knowledge-based subgroups. Instead, a larger number of knowledge-based subgroups is beneficial for performance, such that 2 subgroups is worse for performance when compared with 3 or more subgroups but better for performance when compared with no subgroups or 1 subgroup. Second, we argue that teams perform better when identity-based subgroups are imbalanced yet knowledge-based subgroups are balanced. We also suggest that there are interactive effects between the number and balance of subgroups-however, the nature of this interaction depends on the type of subgroup. To test these predictions, we developed and validated an algorithm that measures the configurational properties of subgroups in organizational work teams. Results of a field study of 326 work teams from a multinational organization support our predictions. PsycINFO Database Record (c) 2013 APA, all rights reserved

  13. Dynamic studies of multiple configurations of CERN's Antiproton Decelerator Target core under proton beam impact

    CERN Document Server

    AUTHOR|(CDS)2248381

    Antiprotons, like many other exotic particles, are produced by impacting high energy proton beams onto fixed targets. At the European Organization for Nuclear Research (CERN), this is done in the Antiproton Decelerator (AD) Facility. The engineering challenges related to the design of an optimal configuration of the AD-Target system derive from the extremely high energy depositions reached in the very thin target core as a consequence of each proton beam impact. A new target design is foreseen for operation after 2021, triggering multiple R&D activities since 2013 for this purpose. The goal of the present Master Thesis is to complement these activities with analytical and numerical calculations, delving into the phenomena associated to the dynamic response of the target core. In this context, two main studies have been carried out. First, the experimental data observed in targets subjected to low intensity proton pulses was cross-checked with analytical and computational methods for modal analysis, applie...

  14. Impact of product configuration systems on product profitability and costing accuracy

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Hvam, Lars

    2017-01-01

    in control of their product assortment, making the right decisions in the sales phase and increasing sales of optimal products. These benefits should have an impact on the company's ability to make more accurate cost estimations in the sales phase, which can positively affect the products’ profitability...... and after a PCS was implemented. The comparison in the case study revealed that increased accuracy of the cost calculations in the sales phase and consequently increased profitability can be achieved by implementing a PCS.......This article aims at analyzing the impact of implementing a product configuration system (PCS) on the increased accuracy of the cost calculations and the increased profitability of the products. Companies that have implemented PCSs have achieved substantial benefits in terms of being more...

  15. An examination of environmental public health organizational and workforce configurations in the Northeast/Mid-Atlantic United States: how do we determine if these configurations impact performance?

    Science.gov (United States)

    Resnick, Beth A; Zablotsky, Joanna; Janus, Erik R; Maggy, Bradley; Burke, Thomas A

    2009-01-01

    Environmental public health (EPH) practice is a vital component of the nation's public health system. Yet, a number of national reports have found that the disjointed structure of the EPH system hinders our ability to protect the public's health. This article examines the EPH organizational and workforce configurations in the US Northeast/Mid-Atlantic region and raises questions as to how to measure whether these varied configurations impact EPH performance. A review of national reports and state-specific documents and 39 EPH practitioner interviews. Study findings revealed wide ranging organizational configurations and workforce challenges in the region. Although this study depicts just one region of the country, it provides insight into the complexity and variety of EPH structures and workforce throughout the nation. This diversity presents challenges in our ability to understand, measure, and evaluate EPH performance. This research has implications for the future of the national EPH system. As we move toward a more "outcomes focused" government, it is essential to the future of EPH to develop better ways to accurately assess, measure, and evaluate EPH performance. These study findings, along with a discussion on how to further advance EPH performance measures, helps facilitate this necessary shift to a more measurable, outcome-based EPH system.

  16. Dynamic Load Measurement of Ballistic Gelatin Impact Using an Instrumented Tube

    Science.gov (United States)

    Seidt, J. D.; Periira, J. M.; Hammer, J. T.; Gilat, A.; Ruggeri, C. R.

    2012-01-01

    Bird strikes are a common problem for the aerospace industry and can cause serious damage to an aircraft. Ballistic gelatin is frequently used as a surrogate for actual bird carcasses in bird strike tests. Numerical simulations of these tests are used to supplement experimental data, therefore it is necessary to use numerical modeling techniques that can accurately capture the dynamic response of ballistic gelatin. An experimental technique is introduced to validate these modeling techniques. A ballistic gelatin projectile is fired into a strike plate attached to a 36 in. long sensor tube. Dynamic load is measured at two locations relative to the strike plate using strain gages configured in a full Wheatstone bridge. Data from these experiments are used to validate a gelatin constitutive model. Simulations of the apparatus are analyzed to investigate its performance.

  17. Tube vibration in industrial size test heat exchanger

    International Nuclear Information System (INIS)

    Halle, H.; Wambsganss, M.W.

    1980-03-01

    Tube vibration data from tests of a specially built and instrumented, industrial-type, shell-and-tube heat exchanger are reported. The heat exchanger is nominally 0.6 m (2 ft) in dia and 3.7 m (12 ft) long. Both full tube and no-tubes-in-window bundles were tested for inlet/outlet nozzles of different sizes and with the tubes supported by seven, equally-spaced, single-segmental baffles. Prior to water flow testing, natural frequencies and damping of representative tubes were measured in air and water. Flow testing was accomplished by increasing the flow rates in stepwise fashion and also by sweeping through a selected range of flow rates. The primary variables measured and reported are tube accelerations and/or displacements and pressure drop through the bundle. Tests of the full tube bundle configuration revealed tube rattling to occur at intermediate flow rates, and fluidelastic instability, with resultant tube impacting, to occur when the flow rate exceeded a threshold level; principally, the four-span tubes were involved in the regions immediately adjacent to the baffle cut. For the range of flow rates tested, fluidelastic instability was not achieved in the no-tubes-in-window bundle; in this configuration the tubes are supported by all seven baffles and are, therefore, stiffer

  18. The impact of product configurators on lead times in engineering-oriented companies

    DEFF Research Database (Denmark)

    Haug, Anders; Hvam, Lars; Mortensen, Niels Henrik

    2011-01-01

    of product configurators on business processes related to the creation of quotes and detailed product specifications. The study documents impressive results of the application of configurator technology. For example, in the data retrieved the use of configurators was estimated to have implied up to a 99...

  19. The impact of NPP Krsko steam generator tube plugging on minimum DNBR at nominal conditions

    International Nuclear Information System (INIS)

    Lajtman, S.

    1996-01-01

    Typically, steam generator tube plugging (SGTP) both decreases the reactor coolant system (RCS) flow rate and the heat transfer surface area of the steam generator. At a constant thermal power and vessel outlet temperature, as tube plugging increases, the vessel average temperature, vessel inlet temperature and steam generator secondary side steam pressure decrease. This paper presents the analysis of impact of SGTP on Minimum Departure from Nucleate Boiling Ratio (MDNBR) at NPP Krsko (NEK), using the Improved Thermal Design Procedure (ITDP), WRB-1 correlation, and COBRA-III-C computer code. No credit was given to high plugging percentage region power reduction resulting from turbine volumetric flow limitations. MDNBR is found to be decreasing with increasing plugging, but not under the limiting values. (author)

  20. Submerged monoxenic culture of the entomopathogenic nematode Steinernema carpocapsae in an internal-loop airlift bioreactor using two configurations of the inner tube.

    Science.gov (United States)

    Chavarría-Hernández, Norberto; Sanjuan-Galindo, René; Rodríguez-Pastrana, Blanca-Rosa; Medina-Torres, Luis; Rodríguez-Hernández, Adriana-Inés

    2007-09-01

    This article reports the submerged culture of the entomopathogenic nematode Steinernema carpocapsae and its symbiotic bacterium, Xenorhabdus nematophila, within an internal-loop airlift bioreactor. Two configurations of the inner cylinder were tested: a standard draft tube (SDT) and a static mixer (SM), as well as two production media: MP1 (500 mL/L whey, among other ingredients) and MP2 (82 mL/L agave-juice from Agave spp., among other ingredients). Three fermentations were carried out: F1 --> SDT-MP1, F2 --> SM-MP1 and F3 --> SM-MP2. The operating conditions were expressed on the basis of dimensionless Reynolds number (Re) and volumetric oxygen transfer coefficient (k(L)a), both of them determined on riser and downcomer sections within the bioreactor. The experiments began with fewer than 1,000 infective juvenile nematode stages (IJ) per mL and at t = 20 d, they achieved (nematodes/mL-%IJ) 222,000-87%, 62,200-23% and 114,600-80%, within F1, F2 and F3 experiments, respectively. Nonetheless, the achieved maximum nematode biomass concentrations (g/L) were F1 --> 408, F2 --> 557 and F3 --> 613, and occurred at t = 16, 10 and 12 d, respectively. The fermentation operating conditions involved 0.042 (-) < Re < 647 (-) and 2.8 x 10(-4) s(-1) < k(L)a < 0.0447 s(-1), as functions of 0.004 m/s < superficial gas velocity (within the riser) < 0.079 m/s, 0.001 m/s < mean downcomer velocity < 0.014 m/s, and culture broth rheological properties which evolved from nearly the Newtonian behaviour to the pseudoplastic one. The maximum IJ concentration was achieved within F1 experiment (193,406 IJ/mL). Also, fermentation conditions involving higher riser-Re and lower downcomer-Re as well as higher nutriment concentrations in culture medium, promote higher nematode biomass concentrations but lower %IJ, maybe as a result of better conditions for the nematode population development.

  1. Experimental Study on Stress Monitoring of Sand-Filled Steel Tube during Impact Using Piezoceramic Smart Aggregates.

    Science.gov (United States)

    Du, Guofeng; Zhang, Juan; Zhang, Jicheng; Song, Gangbing

    2017-08-22

    The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structure under an impact is important for structural health monitoring. In this paper, piezoceramic Smart Aggregates (SAs) are embedded into a quartz Sand-Filled Steel Tube Column (SFSTC) to monitor the internal structural stress during impacts. The piezoceramic smart aggregates are first calibrated by an impact hammer. Tests are conducted to study the feasibility of monitoring the internal stress of a structure. The results reflect that the calibration value of the piezoceramic smart aggregate sensitivity test is in good agreement with the theoretical value, and the output voltage value of the piezoceramic smart aggregate has a good linear relationship with external forces. Impact tests are conducted on the sand-filled steel tube with embedded piezoceramic smart aggregates. By analyzing the output signal of the piezoceramic smart aggregates, the internal stress state of the structure can be obtained. Experimental results demonstrated that, under the action of impact loads, the piezoceramic smart aggregates monitor the compressive stress at different locations in the steel tube, which verifies the feasibility of using piezoceramic smart aggregate to monitor the internal stress of a structure.

  2. Experimental Study on Stress Monitoring of Sand-Filled Steel Tube during Impact Using Piezoceramic Smart Aggregates

    Directory of Open Access Journals (Sweden)

    Guofeng Du

    2017-08-01

    Full Text Available The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structure under an impact is important for structural health monitoring. In this paper, piezoceramic Smart Aggregates (SAs are embedded into a quartz Sand-Filled Steel Tube Column (SFSTC to monitor the internal structural stress during impacts. The piezoceramic smart aggregates are first calibrated by an impact hammer. Tests are conducted to study the feasibility of monitoring the internal stress of a structure. The results reflect that the calibration value of the piezoceramic smart aggregate sensitivity test is in good agreement with the theoretical value, and the output voltage value of the piezoceramic smart aggregate has a good linear relationship with external forces. Impact tests are conducted on the sand-filled steel tube with embedded piezoceramic smart aggregates. By analyzing the output signal of the piezoceramic smart aggregates, the internal stress state of the structure can be obtained. Experimental results demonstrated that, under the action of impact loads, the piezoceramic smart aggregates monitor the compressive stress at different locations in the steel tube, which verifies the feasibility of using piezoceramic smart aggregate to monitor the internal stress of a structure.

  3. Configural coding of facial expressions: the impact of inversion and photographic negative.

    NARCIS (Netherlands)

    Calder, A.J.; Jansen, J.

    2005-01-01

    In previous research we used the composite paradigm (Young, Hellawell, & Hay, 1987) to demonstrate that configural cues are important for interpreting facial expressions. However, different configural cues in face perception have been identified, including holistic processing (i.e., perception of

  4. Impact of CO2 and continental configuration on Late Cretaceous ocean dynamics

    Science.gov (United States)

    Puceat, Emmanuelle; Donnadieu, Yannick; Moiroud, Mathieu; Guillocheau, François; Deconinck, Jean-François

    2014-05-01

    The Late Cretaceous period is characterized by a long-term climatic cooling (Huber et al., 1995; Pucéat et al., 2003; Friedrich et al., 2012) and by major changes in continental configuration with the widening of the Atlantic Ocean, the initiation of the Tethyan ocean closure, and the deepening of the Central Atlantic Gateway. The Late Cretaceous also marks the end of the occurrence of Oceanic Anoxic Events (OAEs), that are associated to enhanced organic carbon burial, to major crises of calcifying organisms, and to possible ocean acidification (Jenkyns, 2010). It has been suggested that the evolution in continental configuration and climate occurring during the Late Cretaceous could have induced a reorganization in the oceanic circulation, that may have impacted the oxygenation state of the oceanic basins and contributed to the disappearance of OAEs (Robinson et al., 2010; Robinson and Vance, 2012). Yet there is no consensus existing on the oceanic circulation modes and on their possible evolution during the Late Cretaceous, despite recent improvement of the spatial and temporal coverage of neodymium isotopic data (ɛNd), a proxy of oceanic circulation (MacLeod et al., 2008; Robinson et al., 2010; Murphy and Thomas, 2012; Robinson and Vance, 2012; Martin et al., 2012; Moiroud et al., 2012). Using the fully coupled ocean-atmosphere General Circulation Model FOAM, we explore in this work the impact on oceanic circulation of changes in continental configuration between the mid- and latest Cretaceous. Two paleogeography published by Sewall et al. (2007) were used, for the Cenomanian/Turonian boundary and for the Maastrichtian. For each paleogeography, 3 simulations have been realized, at 2x, 4x, and 8x the pre-industrial atmospheric CO2 level, in order to test the sensitivity of the modelled circulation to CO2. Our results show for both continental configurations a bipolar mode for the oceanic circulation displayed by FOAM. Using the Cenomanian/Turonian land-sea mask

  5. Analysis of radiative heat transfer impact in cross-flow tube and fin heat exchangers

    Directory of Open Access Journals (Sweden)

    Hanuszkiewicz-Drapała Małgorzata

    2016-03-01

    Full Text Available A cross-flow, tube and fin heat exchanger of the water – air type is the subject of the analysis. The analysis had experimental and computational form and was aimed for evaluation of radiative heat transfer impact on the heat exchanger performance. The main element of the test facility was an enlarged recurrent segment of the heat exchanger under consideration. The main results of measurements are heat transfer rates, as well as temperature distributions on the surface of the first fin obtained by using the infrared camera. The experimental results have been next compared to computational ones coming from a numerical model of the test station. The model has been elaborated using computational fluid dynamics software. The computations have been accomplished for two cases: without radiative heat transfer and taking this phenomenon into account. Evaluation of the radiative heat transfer impact in considered system has been done by comparing all the received results.

  6. Longitudinal tube modulation for chest and abdominal CT examinations: impact on effective patient doses calculations

    Science.gov (United States)

    Zanca, F.; Michielsen, K.; Depuydt, M.; Jacobs, J.; Nens, J.; Lemmens, K.; Oyen, R.; Bosmans, H.

    2011-03-01

    Purpose: In multi-slice CT, manufacturers have implemented automatic tube current modulation (TCM) algorithms. These adjust tube current in the x-y plane (angular modulation) and/or along the z-axis (z-axis modulation) according to the size and attenuation of the scanned body part. Current methods for estimating effective dose (ED) values in CT do not account for such new developments. This study investigated the need to take TCM into account when calculating ED values, using clinical data. Methods: The effect of TCM algorithms as implemented on a GE BrightSpeed 16, a Philips Brilliance 64 and a Siemens Sensation 64 CT scanners was investigated. Here, only z-axis modulation was addressed, considering thorax and abdomen CT examinations collected from 534 adult patients. Commercially available CT dosimetry software (CT expo v.1.7) was used to compute EDTCM (ED accounting for TCM) as the sum of ED of successive slices. A two-step approach was chosen: first we estimated the relative contribution of each slice assuming a constant tube current. Next a weighted average was taken based upon the slice specific tube current value. EDTCM was than compared to patient ED estimated using average mA of all slices. Results and Conclusions: The proposed method is relatively simple and uses as input: the parameters of each protocol, a fitted polynomial function of weighting factors for each slice along the scan length and mA values of the individual patient examination. Results show that z-axis modulation does not have a strong impact on ED for the Siemens and the GE scanner (difference ranges from -4.1 to 3.3 percent); for the Philips scanner the effect was more important, (difference ranges from -8.5 to 6.9 percent), but still all median values approached zero (except for one case, where the median reached -5.6%), suggesting that ED calculation using average mA is in general a good approximation for EDTCM. Higher difference values for the Philips scanner are due to a stronger

  7. Impact of configuration management system of computer center on support of scientific projects throughout their lifecycle

    Science.gov (United States)

    Bogdanov, A. V.; Iuzhanin, N. V.; Zolotarev, V. I.; Ezhakova, T. R.

    2017-12-01

    In this article the problem of scientific projects support throughout their lifecycle in the computer center is considered in every aspect of support. Configuration Management system plays a connecting role in processes related to the provision and support of services of a computer center. In view of strong integration of IT infrastructure components with the use of virtualization, control of infrastructure becomes even more critical to the support of research projects, which means higher requirements for the Configuration Management system. For every aspect of research projects support, the influence of the Configuration Management system is being reviewed and development of the corresponding elements of the system is being described in the present paper.

  8. Impact of configuration management system of computer center on support of scientific projects throughout their lifecycle

    International Nuclear Information System (INIS)

    Bogdanov, A.V.; Yuzhanin, N.V.; Zolotarev, V.I.; Ezhakova, T.R.

    2017-01-01

    In this article the problem of scientific projects support throughout their lifecycle in the computer center is considered in every aspect of support. Configuration Management system plays a connecting role in processes related to the provision and support of services of a computer center. In view of strong integration of IT infrastructure components with the use of virtualization, control of infrastructure becomes even more critical to the support of research projects, which means higher requirements for the Configuration Management system. For every aspect of research projects support, the influence of the Configuration Management system is reviewed and development of the corresponding elements of the system is described in the present paper.

  9. Enzyme immobilization by fouling in ultrafiltration membranes: Impact of membrane configuration and type on flux behavior and biocatalytic conversion efficacy

    DEFF Research Database (Denmark)

    Luo, Jianquan; Meyer, Anne S.; Jonsson, Gunnar Eigil

    2014-01-01

    . The membrane configuration impacted the efficiency of the enzyme-immobilization as well as the biocatalytic-membrane reaction, and the “sandwich mode”, with an extra polypropylene support above the membrane skin layer, worked best due to its high flux and stable conversion. Among the membranes, a GR51PP...... for the different results. The work confirms that fouling-induced enzyme immobilization is a promising option for enhancing biocatalytic productivity, and highlights the significance of the membrane type and configuration for optimal performance....

  10. The contribution of vegetation and landscape configuration for predicting environmental change impacts on Iberian birds

    DEFF Research Database (Denmark)

    Triviño, Maria; Thuiller, Wilfried; Cabeza, Mar

    2011-01-01

    of distributions, but they are rarely considered in such assessments. We explore the consequences of using simulated vegetation structure and composition as well as its associated landscape configuration in models projecting global change effects on Iberian bird species distributions. Both present-day and future...... distributions were modelled for 168 bird species using two ensemble forecasting methods: Random Forests (RF) and Boosted Regression Trees (BRT). For each species, several models were created, differing in the predictor variables used (climate, vegetation, and landscape configuration). Discrimination ability...... using all predictor variables were not significantly better than models fitted with climate variables alone for ca. 50% of the cases. Moreover, models fitted with climate data were always better than models fitted with landscape configuration variables, and vegetation variables were found to correlate...

  11. Product configuration system and its impact on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    2016-01-01

    The purpose of this paper is to identify areas throughout a product's lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat......The purpose of this paper is to identify areas throughout a product's lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process...... for the company in several life cycle processes....

  12. Impact of Supplemental Tutoring Configurations for Preschoolers at Risk for Reading Difficulties

    Science.gov (United States)

    Vukelich, Carol; Justice, Laura M.; Han, Myae

    2013-01-01

    Background: Providing preschoolers at-risk for reading difficulties with additional support is of increasing interest in early childhood education. However, the research on programming in preschool for this additional support is limited and yields inconclusive findings. Objective: The current studies explore different grouping configurations in a…

  13. Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

    Science.gov (United States)

    Hicks, Yolanda R.; Anderson, Robert; Tedder, Sarah

    2016-01-01

    This paper presents results from tests in a NASA Glenn Research Center (GRC) flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include 2D, planar laser-based imaging as well as basic flow visualization of the flame. Four conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics and Environmentally Responsible Aviation Projects were tested.

  14. Aircraft conceptual design study of the canard and threesurface unconventional configurations for the purposes of reducing environmental impacts

    Science.gov (United States)

    Desharnais, Olivier

    With a constant increase in the demand for air transport and today's high fuel price, the aerospace industry is actively searching for new operation methods and technologies to improve efficiency and to reduce the impact it has on the environment. Aircraft manufacturers are exploring many different ways of designing and building better airplanes. One of the considered methods is the use of unconventional aircraft configurations. The objective of this research is to study two configurations, the canard and three-surface, by applying them into a typical high-speed jet aircraft using the conceptual design tools for conventional aircraft available at Bombardier Aerospace (some of them have been modified and validated for the two configurations of interest). This included a weight estimation of the foreplane, an extensive validation of the aerodynamic tool, AVL, and a modification of a physics-based tail-sizing tool. The last tool was found necessary for an accurate foreplane/tailplane sizing, aircraft balancing, establishing the CG envelope and for the assessment of all stability and control requirements. Then, a canard aircraft comparable to the Bombardier research platform aircraft was designed. Final solutions were not obtained from a complete optimization because of some limitations in the design process. The preliminary results show an increase of fuel burn of 10%, leading to an increase of the environmental impacts. The theoretical advantage of not generating any download lift is clearly overwhelmed by the poor effectiveness of the high-lift system. The incapacity to reach a level of high-lift performance close to the one of conventional high-speed aircrafts mostly explains why the canard configuration was found to have no true benefits in this application. Even if no final solution of a three-surface aircraft was obtained in this research, this configuration was identified as being better than the canard case according to the information found in the literature

  15. IMPACT OF SCHEMATIC DESIGNS ON THE COGNITION OF UNDERGROUND TUBE MAPS

    Directory of Open Access Journals (Sweden)

    Z. Liu

    2016-06-01

    Full Text Available Schematic maps have been popularly employed to represent transport networks, particularly underground tube lines (or metro lines, since its adoption by the Official London Underground in early 1930s. Such maps employ straightened lines along horizontal, vertical and diagonal directions. Recently, some researchers started to argue that the distortion in such a schematization may cause big distortion and some new designs are proposed. This project aims to make a comparative analysis of such a schematic design with a new design proposed by Mark Noad in 2011, which makes use of lines along 30º and 60º directions instead of the 45º direction. Tasks have been designed for evaluating the effect of schematic designs on route planning by travellers. The participant was asked to choose the route s/he would take among two or three possible route options and then read the name of the selected transfer station. Eye-tracking technique has been employed to track the map recognition process. Total travel time is used as criterion for effectiveness; completion time and mental work cost are used for efficiency evaluation. It has been found that (1 the design of map style has significant impact on users’ travel decision making, especially map distance and transfer station symbol designs, and (2 the design style of a schematic map will have great impact on the effectiveness and efficiency of map recognition.

  16. Impact of the utilization of a product configuration system on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    The purpose of this paper is to identify areas throughout a product’s lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat...... for the company in several life cycle processes.......The purpose of this paper is to identify areas throughout a product’s lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process...... standardization. This also leads to control and reduce of complexity both in products and processes. To this end, this research attempts to quantify and assess these benefits and is supported by empirical evidence. A case study of an engineering company is used and the results indicate significant improvements...

  17. A nanoscale study of charge extraction in organic solar cells: the impact of interfacial molecular configurations.

    Science.gov (United States)

    Tang, Fu-Ching; Wu, Fu-Chiao; Yen, Chia-Te; Chang, Jay; Chou, Wei-Yang; Gilbert Chang, Shih-Hui; Cheng, Horng-Long

    2015-01-07

    In the optimization of organic solar cells (OSCs), a key problem lies in the maximization of charge carriers from the active layer to the electrodes. Hence, this study focused on the interfacial molecular configurations in efficient OSC charge extraction by theoretical investigations and experiments, including small molecule-based bilayer-heterojunction (sm-BLHJ) and polymer-based bulk-heterojunction (p-BHJ) OSCs. We first examined a well-defined sm-BLHJ model system of OSC composed of p-type pentacene, an n-type perylene derivative, and a nanogroove-structured poly(3,4-ethylenedioxythiophene) (NS-PEDOT) hole extraction layer. The OSC with NS-PEDOT shows a 230% increment in the short circuit current density compared with that of the conventional planar PEDOT layer. Our theoretical calculations indicated that small variations in the microscopic intermolecular interaction among these interfacial configurations could induce significant differences in charge extraction efficiency. Experimentally, different interfacial configurations were generated between the photo-active layer and the nanostructured charge extraction layer with periodic nanogroove structures. In addition to pentacene, poly(3-hexylthiophene), the most commonly used electron-donor material system in p-BHJ OSCs was also explored in terms of its possible use as a photo-active layer. Local conductive atomic force microscopy was used to measure the nanoscale charge extraction efficiency at different locations within the nanogroove, thus highlighting the importance of interfacial molecular configurations in efficient charge extraction. This study enriches understanding regarding the optimization of the photovoltaic properties of several types of OSCs by conducting appropriate interfacial engineering based on organic/polymer molecular orientations. The ultimate power conversion efficiency beyond at least 15% is highly expected when the best state-of-the-art p-BHJ OSCs are combined with present arguments.

  18. Impact of the strong electromagnetic field on the QCD effective potential for homogeneous Abelian gluon field configurations

    International Nuclear Information System (INIS)

    Galilo, Bogdan V.; Nedelko, Sergei N.

    2011-01-01

    The one-loop quark contribution to the QCD effective potential for the homogeneous Abelian gluon field in the presence of an external strong electromagnetic field is evaluated. The structure of extrema of the potential as a function of the angles between chromoelectric, chromomagnetic, and electromagnetic fields is analyzed. In this setup, the electromagnetic field is considered as an external one while the gluon field represents domain structured nonperturbative gluon configurations related to the QCD vacuum in the confinement phase. Two particularly interesting gluon configurations, (anti-)self-dual and crossed orthogonal chromomagnetic and chromoelectric fields, are discussed specifically. Within this simplified framework it is shown that the strong electromagnetic fields can play a catalyzing role for a deconfinement transition. At the qualitative level, the present consideration can be seen as a highly simplified study of an impact of the electromagnetic fields generated in relativistic heavy ion collisions on the strongly interacting hadronic matter.

  19. CT angiography of intracranial arterial vessels: impact of tube voltage and contrast media concentration on image quality

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Holtaas, Stig; Siemund, Roger; Dept. of Radiology, Lund Univ., Lund

    2012-01-01

    Background Computed tomography angiography (CTA) of intracranial arteries has high demands on image quality. Important parameters influencing vessel enhancement are injection rate, concentration of contrast media and tube voltage. Purpose To evaluate the impact of an increase of contrast media concentration from 300 to 400 mg iodine/mL (mgI/mL) and the effect of a decrease of tube voltage from 120 to 90 kVp on vessel attenuation and image quality in CT angiography of intracranial arteries. Material and Methods Sixty-three patients were included into three protocol groups: Group I, 300 mgI/mL 120 kVp; Group II, 400 mgI/mL 120 kVp; Group III, 400 mgI/mL 90 kVp. Hounsfield units (HU) were measured in the internal carotid artery (ICA) and the M1 and M2 segments of the middle cerebral artery. Image quality grading was performed regarding M1 and M2 segments, volume rendering and general image impression. Results The difference in mean HU in ICA concerning the effect of contrast media concentration was statistically significant (P = 0.03) in favor of higher concentration. The difference in ICA enhancement due to the effect of tube voltage was statistically significant (P < 0.01) in favor of lower tube voltage. The increase of contrast medium concentration raised the mean enhancement in ICA with 18% and the decrease of tube voltage raised the mean enhancement with 37%. Image quality grading showed a trend towards improved grading for higher contrast concentration and lower tube voltage. Statistically significant better grading was found for the combined effect of both measures except for general impression (P 0.01-0.05). Conclusion The uses of highly concentrated contrast media and low tube voltage are easily performed measures to improve image quality in CTA of intracranial vessel

  20. Application of 1D Array FBG Configuration for Impact Localization on Composite Wing under Simulated Noise

    Science.gov (United States)

    2016-03-30

    health monitoring (SHM) [5] of aircraft structure can be done so that low velocity impacts, such as due to tool drop, runway debris, bird strike etc...Experimental Set-Up Jabiru UL-D’s, shown in Fig. 2, (Jabiru Aircraft Pty Ltd, Australia ) composite wing was used for the impact localization test under...industry & Energy (MI, Korea) (10047457, Development of aircraft health monitoring integrated measurement system for composite), and by Leading Foreign

  1. Economic burden of neural tube defects and impact of prevention with folic acid: a literature review.

    Science.gov (United States)

    Yi, Yunni; Lindemann, Marion; Colligs, Antje; Snowball, Claire

    2011-11-01

    Neural tube defects (NTDs) are the second most common group of serious birth defects. Although folic acid has been shown to reduce effectively the risk of NTDs and measures have been taken to increase the awareness, knowledge, and consumption of folic acid, the full potential of folic acid to reduce the risk of NTDs has not been realized in most countries. To understand the economic burden of NTDs and the economic impact of preventing NTDs with folic acid, a systematic review was performed on relevant studies. A total of 14 cost of illness studies and 10 economic evaluations on prevention of NTDs with folic acid were identified. Consistent findings were reported across all of the cost of illness studies. The lifetime direct medical cost for patients with NTDs is significant, with the majority of cost being for inpatient care, for treatment at initial diagnosis in childhood, and for comorbidities in adult life. The lifetime indirect cost for patients with spina bifida is even greater due to increased morbidity and premature mortality. Caregiver time costs are also significant. The results from the economic evaluations demonstrate that folic acid fortification in food and preconception folic acid consumption are cost-effective ways to reduce the incidence and prevalence of NTDs. This review highlights the significant cost burden that NTDs pose to healthcare systems, various healthcare payers, and society and concludes that the benefits of prevention of NTDs with folic acid far outweigh the cost. Further intervention with folic acid is justified in countries where the full potential of folic acid to reduce the risk of NTDs has not been realized.

  2. Impacts of Smart Configuration in Pedelec-Sharing: Evidence from a Panel Survey in Madrid

    Directory of Open Access Journals (Sweden)

    András Munkácsy

    2017-01-01

    Full Text Available Despite the recently increasing research interest, this is one of the first studies employing a panel sample of users and nonusers to understand the bike-sharing phenomenon (N=205. On the basis of a novel surveying technique, a case study on the clients of the state-of-the-art bike-sharing scheme of Madrid (Spain is presented. BiciMAD is a system of the latest generation, namely, multimodal demand responsive bike-sharing: a fleet of electric pedal-assisted bicycles (pedelecs with an advanced technology and unique smart service configuration to tackle challenges that may hinder the promotion of cycling and bike-sharing in the city. A statistical test has verified that there is a moderate association between previous intention and actual use of bike-sharing (Cramer’s V = 0.25 and both barriers and motivators of further use have been identified. Indicators on mobility patterns show that although drawing primarily from other sustainable modes of transport, bike-sharing has increased mobility (total number and distance of trips and especially active travel but decreased the perceived travel time.

  3. Impact of reactor configuration on anammox process start-up: MBR versus SBR.

    Science.gov (United States)

    Tao, Yu; Gao, Da-Wen; Fu, Yuan; Wu, Wei-Min; Ren, Nan-Qi

    2012-01-01

    Anaerobic ammonium oxidation (anammox) is an energy saving biological nitrogen removal process which was limited to slow growth rate of anammox bacteria during start-up period. This study investigated the start-up of anammox process by a laboratory sequential batch reactor (SBR) for 218 days and subsequently modified the reactor as a membrane bioreactor (MBR) for 178 days. Modification of a SBR as MBR with installation of an external membrane module resulted in acceleration of specific anammox activity by 19 times. The acceleration of specific anammox activity with MBR was further confirmed by starting-up another MBR for a 242 day period. Molecular microbial analyses showed that Candidatus "Brocadia anammoxidans" and Candidatus "Kuenenia stuttgartiensis" were the dominant species in the inocula and biomass developed in the reactor. The start-up with MBR appeared to be more effective than SBR for the enrichment of anammox bacteria due to high sludge retention property of MBR configuration. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. The impact of HPV status on weight loss and feeding tube use in oropharyngeal carcinoma.

    Science.gov (United States)

    Vangelov, Belinda; Kotevski, Damian P; Williams, Janet R; Smee, Robert I

    2018-04-01

    It has been well established that patients with oropharyngeal carcinoma are at high nutritional risk, with significant weight loss and tube feeding common. Human papillomavirus (HPV)-associated disease has led to a change in the "typical" presentation and nutritional profile of this population. The aim of our study was to determine whether the need for a feeding tube, and weight loss during radiotherapy (RT) in patients with oropharyngeal carcinoma differed with HPV status. Patients who received curative RT ± chemotherapy from January 2011 to January 2016 were included (n = 100). We retrospectively evaluated feeding tube use and timing of insertion (prophylactic vs reactive), percentage weight loss during RT and the prevalence of critical weight loss (CWL) ≥5%. HPV-positive patients had significantly higher weight loss during RT compared to the rest of the cohort (8.4% vs 6.1%, 95%CI 0.8-3.9, p = 0.003). CWL was observed in 86% and in a higher proportion with HPV-positive disease (93%, p = 0.011). Conditional probability modelling analysis revealed, with 74% accuracy, concurrent chemoradiotherapy and HPV-positive status were predictors of CWL when comparing HPV-positive patients to HPV-negative (96%, p = 0.001 and 98%, p = 0.012 respectively). More HPV-positive patients required feeding tubes (n = 43, 63%, p = 0.05), most being reactive (n = 27, 63%). All patients with reactive tubes experienced CWL. The high incidence of CWL in patients with HPV-positive oropharyngeal carcinoma is of concern. Tube feeding continues to be a necessary nutritional intervention in this population and predicting who will require a tube is challenging. Larger, prospective cohort studies are required. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-MV Intensity-Modulated Radiation Therapy Treatment Plans.

    Science.gov (United States)

    Petersen, Nick; Perrin, David; Newhauser, Wayne; Zhang, Rui

    2017-01-01

    The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC) transmission and rounded leaf offset in a commercial treatment planning system (TPS) (Pinnacle 3 , Philips Medical Systems, Andover, MA, USA) on the accuracy of intensity-modulated radiation therapy (IMRT) dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA) measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2) and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being -0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  6. Impact of multileaf collimator configuration parameters on the dosimetric accuracy of 6-MV Intensity-Modulated radiation therapy treatment plans

    Directory of Open Access Journals (Sweden)

    Nick Petersen

    2017-01-01

    Full Text Available The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC transmission and rounded leaf offset in a commercial treatment planning system (TPS (Pinnacle3, Philips Medical Systems, Andover, MA, USA on the accuracy of intensity-modulated radiation therapy (IMRT dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2 and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being −0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  7. Implications of the choice and configuration of hydrologic models on the portrayal of climate change impact

    Science.gov (United States)

    Mendoza, P. A.; Clark, M. P.; Rajagopalan, B.; Mizukami, N.; Gutmann, E. D.

    2013-12-01

    Climate change studies involve several methodological choices that impact the hydrological sensitivities obtained. Among these, hydrologic model structure selection and parameter identification are particularly relevant and usually have a strong subjective component. This subjectivity is not only limited to engineering applications, but also extends to many of our research studies, resulting in problems such as missing processes in our models, inappropriate parameterizations and compensatory effects of model parameters. The goal of this research is to identify the role of model structures and parameter values on the assessment of hydrologic sensitivity to climate change. We conduct our study in three basins located in the Colorado Headwaters Region, using four different hydrologic models (PRMS, VIC, Noah and Noah-MP). We first compare both model performance and climate sensitivities using default parameterizations and parameter values calibrated with the Shuffled Complex Evolution algorithm. Our results demonstrate that calibration doesn't necessarily improve the representation of hydrological processes or decrease inter-model differences in the change of signature measures of hydrologic behavior with respect to a future climate scenario. We found that inter-model differences in hydrologic sensitivities to climate change may be larger than the climate change signal even after models have been calibrated. Results demonstrate that both model choice (after calibration) and parameter selection have important effects in the portrayal of climate change impacts, and work is ongoing to identify more robust modeling strategies that explicitly account for the subjectivity in these choices. Location of the basins of interest Hydrological models used in this study

  8. Stair locomotion in children with spastic hemiplegia: the impact of three different ankle foot orthosis (AFOs) configurations.

    Science.gov (United States)

    Sienko Thomas, Susan; Buckon, Cathleen E; Jakobson-Huston, Sabrina; Sussman, Michael D; Aiona, Michael D

    2002-10-01

    The purpose of this study was to investigate the impact of three different ankle foot orthoses (AFO) configurations on the function and kinematics of stair locomotion in children with spastic hemiplegia. Nineteen children were evaluated barefoot and with a hinged, posterior leaf spring (PLS) and solid AFO during stair ascent and descent. Stair specific items from the Pediatric Evaluation of Disability Inventory (PEDI) were used to evaluate function, while a motion measurement system was used to evaluate kinematics. The PEDI revealed no significant differences between AFOs and barefoot, although a greater percentage of children were able to keep up with their peers while wearing a hinged AFO. At the ankle, the hinged AFO provided the greatest amount of dorsiflexion during stance. All AFOs reduced plantarflexion in comparison to barefoot. The results of this study indicate that for children with spastic hemiplegia the use of an AFO did not impair stair ambulation.

  9. The Impact of Solid Surface Features on Fluid-Fluid Interface Configuration

    Science.gov (United States)

    Araujo, J. B.; Brusseau, M. L. L.

    2017-12-01

    Pore-scale fluid processes in geological media are critical for a broad range of applications such as radioactive waste disposal, carbon sequestration, soil moisture distribution, subsurface pollution, land stability, and oil and gas recovery. The continued improvement of high-resolution image acquisition and processing have provided a means to test the usefulness of theoretical models developed to simulate pore-scale fluid processes, through the direct quantification of interfaces. High-resolution synchrotron X-ray microtomography is used in combination with advanced visualization tools to characterize fluid distributions in natural geologic media. The studies revealed the presence of fluid-fluid interface associated with macroscopic features on the surfaces of the solids such as pits and crevices. These features and respective fluid interfaces, which are not included in current theoretical or computational models, may have a significant impact on accurate simulation and understanding of multi-phase flow, energy, heat and mass transfer processes.

  10. The Impact of Acute Loss of Weight on Eustachian Tube Function

    Directory of Open Access Journals (Sweden)

    Pascoto, Gabriela

    2014-07-01

    Full Text Available Introduction The eustachian tube is one of the key structures responsible for the functional balance of the middle ear. Some clinical conditions associated with tubal malfunction can cause extremely unpleasant symptoms. These symptoms could be triggered by acute loss of weight, for example, after bariatric surgery. Objective To evaluate the frequency and intensity of auditory tube dysfunction symptoms in obese patients after bariatric surgery. Methods Nineteen patients with accepted formal indications for bariatric surgery underwent a hearing evaluation (otoscopy, tonal and vocal audiometry, and impedanceometry and a hearing questionnaire before, at the time of, 3 months after surgery (first postoperative evaluation, and 6 months (second postoperative evaluation after surgery. Patients with a history of ear disease or ear surgery were excluded. Results None of the patients reported tubal dysfunction symptoms before surgery. Postsurgical results showed that 5 (26.3% patients presented symptoms related to dysfunction of the eustachian tube at the first postoperative evaluation. After the 6-month follow-up, 9 (47.3% patients reported symptoms of tubal dysfunction. Conclusion This study suggests that bariatric surgery can cause symptoms of eustachian tube dysfunction, probably due to rapid weight loss and the consequent loss of peritubal fat.

  11. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  12. Volume, nature and potential impact of advertisements on Facebook and YouTube by food brands popular in New Zealand.

    Science.gov (United States)

    Vandevijvere, Stefanie; Aitken, Charlotte; Swinburn, Boyd

    2018-04-13

    To analyse extent, nature and potential impact of marketing by food and beverage brands popular in New Zealand on Facebook and YouTube. Popular food and beverage brands in New Zealand were selected from Socialbakers. Posts on Facebook pages of 45 packaged food, beverage and fast food companies over two months and YouTube channels of 15 companies over two years were analysed for nutritional quality and use of activities, promotional strategies (eg, cartoons) and premium offers (eg, competitions). The 45 brands selected made 762 Facebook posts during October-November 2016. About 28% of posts were videos and 2/3 (63%) contained at least one occasional (ie, unhealthy) food. Promotional strategies were used in 41% of posts, with a famous sportsperson/team being the most frequently used. Premium offers were used in 34% of posts, with competitions being the most frequently used. It was estimated some posts could potentially reach 10% of New Zealand adolescents. The 15 food brands selected posted about 300 videos on their YouTube channels during 2015-2016. About 84% of videos contained food marketing and 77% of products marketed were occasional. Promotional strategies and premium offers were used in 61% and 24% of videos respectively, and the most common marketing techniques were the same as on Facebook. Social media is an important medium for food marketers in New Zealand and promotional strategies and premium offers are frequently used. Methodology needs to be developed to monitor actual exposure to such advertisements.

  13. Impacts of field of view configuration of Cross-track Infrared Sounder on clear-sky observations.

    Science.gov (United States)

    Wang, Likun; Chen, Yong; Han, Yong

    2016-09-01

    Hyperspectral infrared radiance measurements from satellite sensors contain valuable information on atmospheric temperature and humidity profiles and greenhouse gases, and therefore are directly assimilated into numerical weather prediction (NWP) models as inputs for weather forecasting. However, data assimilations in current operational NWP models still mainly rely on cloud-free observations due to the challenge of simulating cloud-contaminated radiances when using hyperspectral radiances. The limited spatial coverage of the 3×3 field of views (FOVs) in one field of regard (FOR) (i.e., spatial gap among FOVs) as well as relatively large footprint size (14 km) in current Cross-track Infrared Sounder (CrIS) instruments limits the amount of clear-sky observations. This study explores the potential impacts of future CrIS FOV configuration (including FOV size and spatial coverage) on the amount of clear-sky observations by simulation experiments. The radiance measurements and cloud mask products (VCM) from the Visible Infrared Imager Radiometer Suite (VIIRS) are used to simulate CrIS clear-sky observation under different FOV configurations. The results indicate that, given the same FOV coverage (e.g., 3×3), the percentage of clear-sky FOVs and the percentage of clear-sky FORs (that contain at least one clear-sky FOV) both increase as the FOV size decreases. In particular, if the CrIS FOV size were reduced from 14 km to 7 km, the percentage of clear-sky FOVs increases from 9.02% to 13.51% and the percentage of clear-sky FORs increases from 18.24% to 27.51%. Given the same FOV size but with increasing FOV coverage in each FOR, the clear-sky FOV observations increases proportionally with the increasing sampling FOVs. Both reducing FOV size and increasing FOV coverage can result in more clear-sky FORs, which benefit data utilization of NWP data assimilation.

  14. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study.

    Science.gov (United States)

    Kumar, Barun; Bhate, Kalyani; Dolas, R S; Kumar, Sn Santhosh; Waknis, Pushkar

    2016-12-01

    Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus.

  15. Dynamics of tubes in fluid with tube-baffle interaction

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1983-09-01

    Three series of tests are performed to evaluate the effects of tube to tube-support-plate (TSP) clearance on tube dynamic characteristics and instability phenomena for tube arrays in crossflow. Test results show that, for relatively large clearances, tubes may possess TSP-inactive modes in which the tubes rattle inside some of the tube-support-plate holes, and that the natural frequencies of TSP-inactive modes are lower than those of TSP-active modes, in which the support plates provide knife-edge type support. Tube response characteristics associated with TSP-inactive modes are sensitive to tube-to-TSP clearance, TSP thickness, excitation amplitude, tube alignment, and the fluid inside the clearance. In addition, tube response is intrinsically nonlinear, with the dominance of TSP-inactive or TSP-active modes depending on the magnitudes of different system parameters. In general, such a system is difficult to model; only a full-scale test can provide all the necessary characteristics. A tube array supported by TSPs with relatively large clearances may be subjected to dynamic instability in some of the TSP-inactive modes; tube response characteristics and impact forces on TSPs for a tube row are studied in detail in this report. Tube displacements associated with the instability of a TSP-inactive mode are small; however, impacts of the tube against TSPs may result in significant damage in a relatively short time. 52 figures

  16. Acetabular configuration and its impact on cup coverage of a subtype of Crowe type 4 DDH with bi-pseudoacetabulum.

    Science.gov (United States)

    Yi, Chengqing; Ma, Chunhui; Wang, Qian; Zhang, Guoqiao; Cao, Yun

    2013-01-01

    The purpose of this study was to explore the acetabular configuration of a special subtype of Crowe type 4 DDH and its impact on cup coverage, which was identified with a particular bi-pseudoacetabulum and an inter-pseudoacetabulum spine structure. The altered bone stock and anatomic structures were believed to be a result of lesser trochanter impingement on the pelvis as observed in all hips of this series, which was supported by the radiographic and intraoperative findings. Acetabular characteristics were depicted by means of radiographic assessment and direct observation during surgery. Preoperatively, the horizontal distance to the hip centre was 80.5 mm on average and 52.9 mm for femoral head height with a significant difference compared to the general series of DDH cases. Anterosuperior bony coverage was found 
to be more adequate with a thicker anterior wall. The postoperative hip centre was restored to the true acetabulum to within 23.4 mm vertically and 25.2 mm horizontally, and sufficient cup containment was achieved when the acetabular inclination angle was below 45°. A larger diameter cup (range 46-50 mm) was employed. No structural bone graft was required, and the medial protrusion technique was infrequently required. This subtype of DDH facilitated cup coverage during THA.

  17. Configuration Management

    International Nuclear Information System (INIS)

    Morcos, A.; Taylor, H. S.

    1989-01-01

    This paper will briefly discuss the reason for and content of configuration management both for new plants and, when adapted, for older plants. It will then address three types of activities a utility may undertake as part of a nuclear CAM program and with which Sargent and Leyden has been actively involved. The first activity is a methodology for preparing design-basis documentation. The second is the identification of essential data required to be kept by the utility in support of the operation of a nuclear plant. The third activity is a computerized classification system of plant components, allowing ready identification of plant functional and physical characteristics. Plant configuration documentation describes plant components, the ways they arranged to interact, and the ways they are enabled to interact. Configuration management, on the other hand, is more than the control of such documentation. It is a dynamic process for ensuring that a plant configuration meets all relevant requirements for safety and economy, even while the configuration changes and even while the requirements change. Configuration management for a nuclear plant is so complex that it must be implemented in phases and modules. It takes advantage of and integrates existing programs. Managing complexity and streamlining the change process become important additional objectives of configuration management. The example activities fulfill essential goals of an overall CAM program: definition of design baseline, definition of essential plant data, and classification of plant components

  18. [Quality of Life of Children with Otitis Media and Impact of Insertion of Transtympanic Ventilation Tubes in a Portuguese Population].

    Science.gov (United States)

    Lameiras, Ana Rita; Silva, Deodato; O Neill, Assunção; Escada, Pedro

    2018-01-31

    Quality of life is an important measure for health-outcome evaluation. Although otitis media is one of the most common childhood diseases, its impact on Portuguese children's quality of life is unknown. The aim of this study is to determine the quality of life of Portuguese children with chronic otitis media with effusion and/or recurrent acute otitis media and the short-term impact of transtympanic ventilation tubes, using the Portuguese version of the OM-6 questionnaire, a valid, reliable and sensitive instrument to evaluate the health-related quality of life in children with otitis media. This study was conducted in a tertiary referral center, to where children are referred from primary care and hospital pediatric consultations. The Portuguese version of the OM-6 questionnaire was applied to children with chronic otitis media with effusion and/or recurrent acute otitis media. The instrument was re-administered at two months postoperatively to a group of children who underwent tympanostomy tube placement, to evaluate the change in quality of life with the surgical procedure. The study involved a sample of 169 children, aged between 6 months and 12 years (mean: 4.20 ± 2.05 years). The average score in the survey was 3.3 ± 1.47, of a maximum of 7 (worst quality of life). The domains 'caregiver concerns', 'hearing loss' and 'physical suffering' had the highest scores. The domain 'hearing loss' was correlated with the domain 'speech impairment' (rs = 0.41; p Children with chronic otitis media with effusion had lower scores on the domain 'physical suffering', while children with recurrent acute otitis media had lower scores in the domain 'hearing loss' and higher scores in the domain 'emotional distress'. There was an improvement in the quality of life in all the dimensions studied by the questionnaire after surgery. The improvement was large in 55%, moderate in 15% and small in 10% of the cases. The presence of otorrhea postoperatively did not decrease the quality

  19. Impact of tree planting configuration on canopy interception and soil hydrological properties: Implications for flood mitigation in silvopastoral systems

    Science.gov (United States)

    Lunka, Peter; Patil, Sopan

    2015-04-01

    Compaction of upper soil layers by intensive sheep grazing has been connected with increased local flood risk in silvopastoral systems. A 12 week field study was conducted at the Henfaes Research Station near Bangor, Wales to compare two silvopastoral configurations, trees planted in fenced off clumps and trees planted evenly spaced, in terms of canopy throughfall, soil water infiltration and soil bulk density. The study's aim was to characterize the potential of these tree planting configurations to reduce local flood risk. The study site (Henfaes) was established in 1992 on 14 ha of agricultural land and is part of the Silvopastoral National Network Experiment sites that have been set up across the UK to examine the potential of silvopasture and agroforestry on UK farms. Automated throughfall gauges were installed in each silvopastoral treatment along with a similarly designed control gauge located in the grazed control pasture. Soil water infiltration and bulk density were measured 20 times in a stratified random design for each treatment and the control. Soil infiltration capacity in the clumped configuration was significantly higher than in the even spaced configuration and control pasture. The clumped configuration had mean infiltration capacity 504% greater than the control pasture and 454% greater than the even spaced configuration. Canopy interception was higher in the clumped trees than in the evenly spaced trees. Average canopy interception was 34% in the clumped treatment and 28% in the evenly spaced treatment. Soil bulk density was lower in the clumped configuration than in the control pasture and evenly spaced configuration. Results suggest that in silvopastoral systems the clumped tree configuration is more likely to reduce local flood risk than the evenly spaced tree configuration due to enhanced infiltration and increased canopy interception.

  20. Onset of airflow limitation in a collapsible tube model: impact of surrounding pressure, longitudinal strain, and wall folding geometry.

    Science.gov (United States)

    Amatoury, Jason; Kairaitis, Kristina; Wheatley, John R; Bilston, Lynne E; Amis, Terence C

    2010-11-01

    We studied the impact of wall strain and surrounding pressure on the onset of airflow limitation in a thin-walled "floppy" tube model. A vacuum source-generated steady-state (baseline) airflow (0-350 ml/s) through a thin-walled latex tube (length 80 mm, wall thickness 0.23 mm) enclosed within a rigid, sealed, air-filled, cylindrical chamber while upstream minus downstream pressure, chamber pressure (Pc), and lumen geometry [in-line digital camera; segmentation (Amira 5.2.2) and analysis (Rhinoceros 4) software] were monitored. Longitudinal strain (S; 0-62.5%) and Pc (0-20 cmH(2)O) combinations were imposed, and Pc associated with onset of 1) reduced airflow and 2) fully developed airflow limitation recorded. At any strain, increasing Pc resulted in a decrease in airflow. Across all baseline airflow, threshold pressure was 1-7 cmH(2)O for S cmH(2)O at S = 25% and 37.5%, and 5-7 cmH(2)O at S = 50% and 62.5%. Pc associated with fully developed airflow limitation was 4-6 cmH(2)O for S 20 cmH(2)O at S = 25% (i.e., no flow limitation), 18 cmH(2)O at S = 37.5%, and 8-12 cmH(2)O at S = 50% and 62.5%. Lumen area decreased with increasing Pc but was 1) larger at S = 25% and 2) characterized by bifold narrowing at S < 25% and trifold narrowing at S ≥ 25%. In conclusion, tube function was modulated by Pc vs. S interactions, with S = 25% producing trifold lumen narrowing, maximal patency, and no airflow limitation. Findings may have implications for understanding peripharyngeal tissue pressure and pharyngeal wall strain effects on passive pharyngeal airway function in humans.

  1. The impact of the AEC mode of tube current on the dose at CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Kim, Kwang Cheol [Dept. of of Nuclear Engineering, Chosun University,Gwangju (Korea, Republic of)

    2016-11-15

    In this study, the automatic exposure control (AEC) modes of tube current (SIEMENSCare Dose 4D and GE AEC mode) that CT manufacturers are using was applied to neck, chest and abdomen in order to determine the difference in the respective dose parameters (CTDIvol, DLP and mSv) resulting from the dose reduction. Equipment in use at C university adopted Care Dose 4D of Siemens and AEC mode of General Electric (GE), and the x-ray exposure conditions were adjusted to be as identical as possible between the experiments. For the assessment of the dose reduction, the differences between the doses with and without the use of the tube current AEC mode by the respective manufacturer were measured for each body part including neck, chest and abdomen of a human phantom, Rando Phantom (Art-200x, Fluke Biomedical, USA). First, the assessment of SIEMENS-Care Dose 4D yielded the following results. At the neck, the automatic exposure control resulted in a 3.3% reduction in CTDIvol and DLP, and a 3% reduction in the effective dose, mSv, compared to manual exposure control. The automatic exposure control at the chest displayed the reduction in CTDIvol and DLP by 25.5%, and in the effective dose, mSv, by 25.4% compared to the manual exposure control. In case of abdomen, CTDIvol and DLP were shown to be reduced by 16%, and the effective dose (mSv) by 16.3% under the automatic exposure control compared to the manual exposure. Second, the assessment results of GE AEC mode are as follows. The automatic exposure control at the neck resulted in a 45.1% reduction in CTDIvol and DLP, and a 44.7% reduction in the effective dose (mSv) in comparison to the manual exposure control. At the chest, the automatic exposure control displayed a 47.6% reduction in CTDIvol and DLP, and a 47.5% reduction in the effective dose, mSv, compared to the manual exposure control. At the abdomen, it was shown that CTDIvol and DLP were reduced by 26.9%, and the effective dose (mSv) by 26.8% under the automatic

  2. Building lab-scale x-ray tube based irradiators

    Science.gov (United States)

    The construction of economical x-ray tube based irradiators in a variety of configurations is described using 1000 Watt x-ray tubes. Single tube, double tube, and four tube designs are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small s...

  3. Feeding Tubes

    Science.gov (United States)

    ... the TPN. Tubes Used for Enteral Feeds NG (Nasogastric Tube) A flexible tube is placed via the nose, ... portion of the small intestine Naso – nose NG – Nasogastric Tube -ostomy – new opening Percutaneous – through the skin PEJ – ...

  4. The Impact of Model Configuration and Large-Scale, Upper-Level Forcing on CRM-Simulated Convective Systems

    Science.gov (United States)

    Tao, W.-K.; Zeng, X.; Shie, C.-L.; Starr, D.; Simpson, J.

    2004-01-01

    Real clouds and cloud systems are inherently three-dimensional (3D). Because of the limitations in computer resources, however, most cloud-resolving models (CRMs) today are still two-dimensional (2D, see a brief review by Tao 2003). Only recently have 3D experiments been performed for multi-day periods for tropical cloud systems with large horizontal domains at the National Center for Atmospheric Research, at NOAA GFDL, at the U. K. Met. Office, at Colorado State University and at NASA Goddard Space Flight Center (Tao 2003). At Goddard, a 3D Goddard Cumulus Ensemble (GCE) model was used to simulate periods during TOGA COARE (December 19-27, 1992), GATE (September 1-7, 1974), SCSMEX (June 2-11, 1998), ARM (June 26-30, 1997) and KWAJEX (August 7-13, August 18-21, and August 29-September 12, 1999) using a 512 km domain (with 2-kilometer resolution). The results indicate that surface precipitation and latent heating profiles are similar between the 2D and 3D GCE model simulations. However, there are difference in radiation, surface fluxes and precipitation characteristics. The 2D GCE model was used to perform a long-term integration on ARM/GCSS case 4 (22 days at the ARM southern Great Plains site in March 2000). Preliminary results showed a large temperature bias in the upper troposphere that had not been seen in previous tropical cases. The major objectives of this paper are: (1) to determine the sensitivities to model configuration (ie., 2D in west-east, south-north or 3D), (2) to identify the differences and similarities in the organization and entrainment rates of convection between 2D- and 3D-simulated ARM cloud systems, and (3) assess the impact of upper tropospheric forcing on tropical and ARM case 4 cases.

  5. The impact of ventilation tubes in otitis media on the risk of cholesteatoma on a national level

    DEFF Research Database (Denmark)

    Djurhuus, Bjarki Ditlev; Christensen, Kaare; Skytthe, Axel

    2015-01-01

    OBJECTIVE: To estimate the impact of treatment with middle ear ventilation tube insertion (VTI) in children with otitis media (OM) on the risk of cholesteatoma on a national level. METHODS: Data were obtained from the Danish National Patient Register, the National Health Service Register...... and Statistics Denmark. Cumulative incidence proportions were estimated by the Kaplan-Meier method and hazard ratios with Cox regression analysis. The first surgically treated middle ear cholesteatoma in a child (STMEC1) was considered an event. RESULTS: A total of 217,206 children, born after December 31, 1996......, who had VTI from January 1, 1997 to August 31, 2011 were identified. Of these, 374 subsequently had a STMEC1. A corresponding 36,981 children without any VTI were identified for comparison using a random 5% sample of the Danish population. Of these, 5 had a STMEC1. The cumulative incidence proportion...

  6. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).

    Science.gov (United States)

    Calmette, Leyla; Ibrahim, Firas; Gouin, Isabelle; Horellou, Marie-Hélène; Mazoyer, Élisabeth; Fontenay, Michaela; Flaujac, Claire

    2017-02-01

    Samples transported by pneumatic tube system are submitted to forces of acceleration and deceleration which can affect laboratory parameters. At Cochin hospital, majority of samples of hemostasis, except for platelets tests, are transported by pneumatic tube system. The objective of this study was to evaluate the impact of a pneumatic tube system (PTS) transport compared to hand-delivered transport on samples and to qualify Cochin hospital PTS according to requirements of standard ISO 15189. A bibliographical study was made and showed that pneumatic tube system particularly influences platelets tests. Four citrate tubes were collected in 5 healthy volunteers in the maternity: 2 tubes were transported by PTS and 2 others were hand-delivered to the laboratory. Five coagulation tests were analyzed: prothrombine time (PT), activated partial thromboplastin time (aPTT), factor (F) V, FVIII and platelet closure time with PFA-100TM collagen/epinephrine. For each volunteer, the results obtained by PTS and by hand-delivered transport were compared with formula usually used for biological analysis retake: 2.8 x standard deviation of reproductibility variation coefficient (SH GTA 01, COFRAC). This study did not show an impact of PTS on PT, aPTT, FV and FVIII. For PFA-100TM collagen/epinephrine, we noted an impact on 2/5 volunteers. These results, in agreement with the literature, led to the conclusion that Cochin hospital PTS is in compliance to transport samples for usual coagulation tests except platelet tests. This study allowed to issue French recommendations for PTS transport of hemostasis tubes qualification available on "Groupe français d'hémostase et thrombose" Web site.

  7. Hypertext Configurations

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2017-01-01

    , links, interactive processes, and time scalings, and that the hypertext configuration is a major but not sole source of the messiness of big data. The notion of hypertext will be revalidated, placed at the center of the interpretation of networked digital media, and used in the analysis of the fast...

  8. Tracheal tube airleak in clinical practice and impact on tidal volume measurement in ventilated neonates.

    Science.gov (United States)

    Mahmoud, Ramadan A; Proquitté, Hans; Fawzy, Naglaa; Bührer, Christoph; Schmalisch, Gerd

    2011-03-01

    To determine the prevalence, size, and factors affecting tracheal tube (TT) leak in clinical practice and their influence on the displayed tidal volume (Vt) in ventilated newborn infants using uncuffed TTs. Monitoring of Vt is important for implementation of lung-protective ventilation strategies but becomes meaningless in the presence of large TT airleaks. Retrospective clinical study. Neonatal intensive care unit. Patient records of 163 neonates ventilated with Babylog 8000 for ≥ 5 hrs with a median (range) gestation age of 31.1 wks (23.3-41.9 wks) and a median birth weight of 1470 g (410-4475 g) were evaluated. : Ventilatory settings, TT leak, and Vt were recorded every 3 hrs. The lowest, median, and highest TT leaks were noted on the day the first TT leak (>5%) occurred, the day on which TT leak peaked, and the day of extubation. A TT leak of >5% was seen in 122 (75%) infants. Neonates with TT leak, compared with those without TT leak, had a longer duration of mechanical ventilation (p 40% commonly seen on the third day of mechanical ventilation. Regression analysis showed that a TT leak of 40% indicated that the displayed Vt was underestimated by 1.2 mL/kg (about 24% of target Vt). TT leak is highly variable, and TT leak of >40% with clinically relevant Vt errors occurred in nearly half of all ventilated neonates. Preterm infants of low birth weight and with small-diameter TTs ventilated for a long period were at greater risk of TT leak.

  9. Investigation of PCDD/F emissions from mobile source diesel engines: impact of copper zeolite SCR catalysts and exhaust aftertreatment configurations.

    Science.gov (United States)

    Liu, Z Gerald; Wall, John C; Barge, Patrick; Dettmann, Melissa E; Ottinger, Nathan A

    2011-04-01

    This study investigated the impact of copper zeolite selective catalytic reduction (SCR) catalysts and exhaust aftertreatment configurations on the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from mobile source diesel engines. Emissions of PCDD/Fs, reported as the weighted sum of 17 congeners called the toxic equivalency quotient (TEQ), were measured using a modified EPA Method 0023A in the absence and presence of exhaust aftertreatment. Engine-out emissions were measured as a reference, while aftertreatment configurations included various combinations of diesel oxidation catalyst (DOC), diesel particulate filter (DPF), Cu-zeolite SCR, Fe-zeolite SCR, ammonia oxidation catalyst (AMOX), and aqueous urea dosing. In addition, different chlorine concentrations were evaluated. Results showed that all aftertreatment configurations reduced PCDD/F emissions in comparison to the engine-out reference, consistent with reduction mechanisms such as thermal decomposition or combined trapping and hydrogenolysis reported in the literature. Similarly low PCDD/F emissions from the DOC-DPF and the DOC-DPF-SCR configurations indicated that PCDD/F reduction primarily occurred in the DOC-DPF with no noticeable contribution from either the Cu- or Fe-zeolite SCR systems. Furthermore, experiments performed with high chlorine concentration provided no evidence that chlorine content has an impact on the catalytic synthesis of PCDD/Fs for the chlorine levels investigated in this study.

  10. Impact of line parameter database, continuum absorption, full grind configuration, and L1B update on GOSAT TIR methane retrieval

    Science.gov (United States)

    Yamada, A.; Saitoh, N.; Nonogaki, R.; Imasu, R.; Shiomi, K.; Kuze, A.

    2016-12-01

    The thermal infrared (TIR) band of Thermal and Near-infrared Sensor for Carbon Observation Fourier Transform Spectrometer (TANSO-FTS) onboard Greenhouse Gases Observing Satellite (GOSAT) observes CH4 profile at wavenumber range from 1210 cm-1 to 1360 cm-1 including CH4 ν4 band. The current retrieval algorithm (V1.0) uses LBLRTM V12.1 with AER V3.1 line database to calculate optical depth. LBLRTM V12.1 include MT_CKD 2.5.2 model to calculate continuum absorption. The continuum absorption has large uncertainty, especially temperature dependent coefficient, between BPS model and MT_CKD model in the wavenumber region of 1210-1250 cm-1(Paynter and Ramaswamy, 2014). The purpose of this study is to assess the impact on CH4 retrieval from the line parameter databases and the uncertainty of continuum absorption. We used AER v1.0 database, HITRAN2004 database, HITRAN2008 database, AER V3.2 database, and HITRAN2012 database (Rothman et al. 2005, 2009, and 2013. Clough et al., 2005). AER V1.0 database is based on HITRAN2000. The CH4 line parameters of AER V3.1 and V3.2 databases are developed from HITRAN2008 including updates until May 2009 with line mixing parameters. We compared the retrieved CH4 with the HIPPO CH4 observation (Wofsy et al., 2012). The difference of AER V3.2 was the smallest and 24.1 ± 45.9 ppbv. The differences of AER V1.0, HITRAN2004, HITRAN2008, and HITRAN2012 were 35.6 ± 46.5 ppbv, 37.6 ± 46.3 ppbv, 32.1 ± 46.1 ppbv, and 35.2 ± 46.0 ppbv, respectively. Compare AER V3.2 case to HITRAN2008 case, the line coupling effect reduced difference by 8.0 ppbv. Median values of Residual difference from HITRAN2008 to AER V1.0, HITRAN2004, AER V3.2, and HITRAN2012 were 0.6 K, 0.1 K, -0.08 K, and 0.08 K, respectively, while median values of transmittance difference were less than 0.0003 and transmittance differences have small wavenumber dependence. We also discuss the retrieval error from the uncertainty of the continuum absorption, the test of full grid

  11. Quality of Life of Children with Otitis Media and Impact of Insertion of Transtympanic Ventilation Tubes in a Portuguese Population

    Directory of Open Access Journals (Sweden)

    Ana Rita Lameiras

    2018-01-01

    Full Text Available Introduction: Quality of life is an important measure for health-outcome evaluation. Although otitis media is one of the most common childhood diseases, its impact on Portuguese children’s quality of life is unknown. The aim of this study is to determine the quality of life of Portuguese children with chronic otitis media with effusion and/or recurrent acute otitis media and the short-term impact of transtympanic ventilation tubes, using the Portuguese version of the OM-6 questionnaire, a valid, reliable and sensitive instrument to evaluate the health-related quality of life in children with otitis media. Material and Methods: This study was conducted in a tertiary referral center, to where children are referred from primary care and hospital pediatric consultations. The Portuguese version of the OM-6 questionnaire was applied to children with chronic otitis media with effusion and/or recurrent acute otitis media. The instrument was re-administered at two months postoperatively to a group of children who underwent tympanostomy tube placement, to evaluate the change in quality of life with the surgical procedure. Results: The study involved a sample of 169 children, aged between 6 months and 12 years (mean: 4.20 ± 2.05 years. The average score in the survey was 3.3 ± 1.47, of a maximum of 7 (worst quality of life. The domains ‘caregiver concerns’, ‘hearing loss’ and ‘physical suffering’ had the highest scores. The domain ‘hearing loss’ was correlated with the domain ‘speech impairment’ (rs = 0.41; p < 0.001 and the domain ‘physical suffering’ correlated with the domain ‘activity limitation’ (rs = 0.47; p < 0.001. There was a correlation between the score on ‘hearing loss’ and the presence of conduction hearing loss (χ2 (6 = 24.662; p = 0.022. Children with chronic otitis media with effusion had lower scores on the domain ‘physical suffering’, while children with recurrent acute otitis media had lower

  12. Vaccine-critical videos on YouTube and their impact on medical students' attitudes about seasonal influenza immunization: a pre and post study.

    Science.gov (United States)

    Robichaud, Pierre; Hawken, Steven; Beard, Leslie; Morra, Dante; Tomlinson, George; Wilson, Kumanan; Keelan, Jennifer

    2012-05-28

    YouTube is a video-sharing platform that is increasingly utilized to share and disseminate health-related information about immunization. Using a pre-post survey methodology, we compared the impact of two of the most popular YouTube videos discussing seasonal influenza vaccine, both vaccine-critical, on the attitudes towards immunizing of first year medical students attending a Canadian medical school. Forty-one medical students were randomized to view either a scientifically styled, seemingly "evidence-based", vaccine-critical video or a video using anecdotal stories of harms and highly sensationalized imagery. In the pre-intervention survey, medical students frequently used YouTube for all-purposes, while 42% used YouTube for health-related purposes and 12% used YouTube to search for health information. While medical students were generally supportive of immunizing, there was suboptimal uptake of annual influenza vaccine reported, and a subset of our study population expressed vaccine-critical attitudes and behaviors with respect to seasonal influenza. Overall there was no significant difference in pre to post attitudes towards influenza immunization nor were there any differences when comparing the two different vaccine-critical videos. The results of our study are reassuring in that they suggest that medical students are relatively resistant to the predominately inaccurate, vaccine-critical messaging on YouTube, even when the message is framed as scientific reasoning. Further empirical work is required to test the popular notion that information disseminated through social media platforms influences health-related attitudes and behaviors. However, our study suggests that there is an opportunity for public health to leverage YouTube to communicate accurate and credible information regarding influenza to medical students and others. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Impact of plastic softening of over-aged CuCrZr alloy heat sink tube on the structural reliability of a plasma-facing component

    International Nuclear Information System (INIS)

    Miskiewicz, M.; You, J.-H.

    2008-01-01

    Precipitation-hardened CuCrZr alloy is used in fusion experiments as heat sink material for water-cooled plasma-facing components. When exposed to long-term high-heat-flux (HHF) plasma operation, CuCrZr will undergo over-ageing and thus plastic softening. In this situation, the softened CuCrZr heat sink tube will suffer from substantial plastic straining and thus fatigue damage in the course of the cyclic HHF loads. In this paper, a computational case study is presented regarding the cyclic plasticity behaviour of the over-aged CuCrZr cooling tube in a water-cooled tungsten mono-block divertor component. Finite element analysis was performed assuming ten typical HHF load cycles and using the Frederick-Armstrong constitutive equation together with corresponding material parameters. It was shown that plastic shakedown and low cycle fatigue (LCF) would be caused in the heat sink tube when softening of CuCrZr should occur. On the other hand, neither elastic shakedown nor cumulative plastic strain (ratchetting) was found. LCF design life of the CuCrZr tube was estimated based on the ITER materials handbook considering both hardened and softened states of CuCrZr. Substantial impact of softening of the CuCrZr alloy on the LCF lifetime of the heat sink tube was demonstrated

  14. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  15. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  16. Impact of an online educational program on pharmacy students' knowledge of folic acid and neural tube defects.

    Science.gov (United States)

    Bykhovsky, Margarita; Meier, Mary Frances K; Mager, Natalie A DiPietro

    2014-10-01

    Pharmacy students must receive adequate training regarding folic acid for the prevention of neural tube defects (NTDs). Pharmacy students' knowledge should be evaluated and effective methods utilized to improve it, if needed. The objective of this study was to assess baseline knowledge among third-year students in a 0-6 Doctor of Pharmacy program and to evaluate the impact of an online educational video. Baseline knowledge was assessed by a pretest adapted with permission from the March of Dimes (MOD). Students watched a 30-minute MOD video and completed a posttest. Nine months later, students completed a longitudinal posttest. Analysis of variance was used to assess differences in the percentage of correct responses to each question. A total of 133 (90.5%) students completed the educational program and 105 (78.9%) completed the longitudinal test. Statistically significant improvements in knowledge from baseline were seen for 9 of 10 questions on the posttest and for 6 of 10 questions on the longitudinal test. Online videos are tools to teach pharmacy students key information regarding folic acid and NTD; however, material should be reinforced in experiential education as well. Counseling women of childbearing potential about folic acid fulfills an important public health need. © The Author(s) 2014.

  17. The Impact of Variable Inlet Mixture Stratification on Flame Topology and Emissions Performance of a Premixer/Swirl Burner Configuration

    Directory of Open Access Journals (Sweden)

    P. Koutmos

    2012-01-01

    Full Text Available The work presents the assessment of a low emissions premixer/swirl burner configuration utilizing lean stratified fuel preparation. An axisymmetric, single- or double-cavity premixer, formed along one, two, or three concentric disks promotes propane-air premixing and supplies the combustion zone at the afterbody disk recirculation with a radial equivalence ratio gradient. The burner assemblies are operated with a swirl co-flow to study the interaction of the recirculating stratified flame with the surrounding swirl. A number of lean and ultra-lean flames operated either with a plane disk stabilizer or with one or two premixing cavity arrangements were evaluated over a range of inlet mixture conditions. The influence of the variation of the imposed swirl was studied for constant fuel injections. Measurements of turbulent velocities, temperatures, OH* chemiluminescence and gas analysis provided information on the performance of each burner set up. Comparisons with Large Eddy Simulations, performed with an 11-step global chemistry, illustrated the flame front interaction with the vortex formation region under the influence of the variable inlet mixture stratifications. The combined effort contributed to the identification of optimum configurations in terms of fuel consumption and pollutants emissions and to the delineation of important controlling parameters and limiting fuel-air mixing conditions.

  18. Quantification of character-impacting compounds in Ocimum basilicum and 'Pesto alla Genovese' with selected ion flow tube mass spectrometry.

    Science.gov (United States)

    Amadei, Gianluca; Ross, Brian M

    2012-02-15

    Basil (Ocimum basilicum) is an important flavourant plant which constitutes the major ingredient of the pasta sauce 'Pesto alla Genovese'. The characteristic smell of basil stems mainly from a handful of terpenoids (methyl cinnamate, eucalyptol, linalool and estragole), the concentration of which varies according to basil cultivars. The simple and rapid analysis of the terpenoid constituents of basil would be useful as a means to optimise harvesting times and to act as a quality control process for basil-containing foodstuffs. Classical analytical techniques such as gas chromatography/mass spectrometry (GC/MS) are, however, slow, technically demanding and therefore less suitable for routine analysis. A new chemical ionisation technique which allows real-time quantification of traces gases, Selected Ion Flow Tube Mass Spectrometry (SIFT-MS), was therefore utilised to determine its usefulness for the assay of terpenoid concentrations in basil and pesto sauce headspace. Trace gas analysis was performed using the NO(+) precursor ion which minimised interference from other compounds. Character-impacting compound concentration was measured in basil headspace with good reproducibility and statistically significant differences were observed between cultivars. Quantification of linalool in pesto sauce headspace proved more difficult due to the presence of interfering compounds. This was resolved by careful selection of reaction product ions which allowed us to detect differences between various commercial brands of pesto. We conclude that SIFT-MS may be a valid tool for the fast and reproducible analysis of flavourant terpenoids in basil and basil-derived foodstuffs. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Design options for reducing the impact of the fill-tube in ICF implosion experiments on the NIF

    Science.gov (United States)

    Weber, Christopher R.; Berzak Hopkins, L. F.; Casey, D. T.; Clark, D. S.; Hammel, B. A.; Le Pape, S.; Macphee, A.; Milovich, J.; Pickworth, L. A.; Robey, H. F.; Smalyuk, V. A.; Stadermann, M.; Felker, S. J.; Nikroo, A.; Thomas, C. A.; Crippen, J.; Rice, N.

    2017-10-01

    Inertial Confinement Fusion (ICF) capsules on the National Ignition Facility (NIF) are filled with thermonuclear fuel through a fill-tube. When the capsule implodes, perturbations caused by the fill-tube allow ablator material to mix into the hot spot and reduce fusion performance. This talk will explore several design options that attempt to reduce this damaging effect. Reducing the diameter of the fill-tube and its entrance hole is the obvious course and has been tested in experiments. Simulations also show sensitivity to the amount of glue holding the fill-tube to the capsule and suggest that careful control of this feature can limit the amount of injected mass. Finally, an off-axis fill-tube reduces the initial squirt of material into the fuel and may be a way of further optimizing this engineering feature. Work performed under the auspices of the U.S. D.O.E. by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  20. A MECHANISTIC-EMPIRICAL IMPACT ANALYSIS OF DIFFERENT TRUCK CONFIGURATIONS ON A JOINTED PLAIN CONCRETE PAVEMENT (JPCP

    Directory of Open Access Journals (Sweden)

    Lubinda F. Walubita

    2017-12-01

    Full Text Available Until the last decade, the 1993 American Association of State Highway and Transportation Officials (AASHTO design guide has been traditionally used for the design of flexible and rigid pavements in the USA and some parts of the world. However, because of its inability to meet the new traffic and material challenges, a Mechanistic Empirical Pavement Design Guide (MEPDG was introduced based on an NCHRP 1-37 A study conducted in 2004. This study used the MEPDG software and associated models to determine, through comparative truck damage analysis, the effects of nine different truck configurations on a 12 inch-jointed plain concrete pavement (JPCP. The study recorded truck damages at the end of each analysis period (40 years and comparatively analyzed the relative pavement damage in terms of fatigue cracking, faulting, and surface roughness. The results indicated that the most critical damage to the concrete pavement was caused by truck cases with high and uneven load distribution and relatively smaller size axles group (e.g. tandem. Other key findings included the following; (1 increase in damage when the truckloads were shifted between the same size axles, (2 decrease in truck damage when the truckloads were shifted from tandem axle to quad axles, and (3 no change in truck damage when the axle spacing was increased between wheels of a quad axle.

  1. Use of large-scale multi-configuration EMI measurements to characterize heterogeneous subsurface structures and their impact on crop productivity

    Science.gov (United States)

    Brogi, Cosimo; Huisman, Johan Alexander; Kaufmann, Manuela Sarah; von Hebel, Christian; van der Kruk, Jan; Vereecken, Harry

    2017-04-01

    Soil subsurface structures can play a key role in crop performance, especially during water stress periods. Geophysical techniques like electromagnetic induction EMI have been shown to be able of providing information about dominant shallow subsurface features. However, previous work with EMI has typically not reached beyond the field scale. The objective of this study is to use large-scale multi-configuration EMI to characterize patterns of soil structural organization (layering and texture) and the associated impact on crop vegetation at the km2 scale. For this, we carried out an intensive measurement campaign and collected high spatial resolution multi-configuration EMI data on an agricultural area of approx. 1 km2 (102 ha) near Selhausen (North Rhine-Westphalia, Germany) with a maximum depth of investigation of around 2.5 m. We measured using two EMI instruments simultaneously with a total of nine coil configurations. The instruments were placed inside polyethylene sleds that were pulled by an all-terrain-vehicle along parallel lines with a spacing of 2 to 2.5 m. The driving speed was between 5 and 7 km h-1 and we used a 0.2 Hz sampling frequency to obtain an in-line resolution of approximately 0.3 m. The survey area consists of almost 50 different fields managed in different way. The EMI measurements were collected between April and December 2016 within a few days after the harvest of each field. After data acquisition, EMI data were automatically filtered, temperature corrected, and interpolated onto a common grid. The resulting EMI maps allowed us to identify three main areas with different subsurface heterogeneities. The differences between these areas are likely related to the late quaternary geological history (Pleistocene and Holocene) of the area that resulted in spatially variable soil texture and layering, which has a strong impact on spatio-temporal soil water content variability. The high resolution surveys also allowed us to identify small scale

  2. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  3. Cross sections for electron-impact excitation of krypton from the levels of 4p6, 4p55s, and 4p55p configurations

    International Nuclear Information System (INIS)

    Zeng Jiaolong; Yuan Jianmin; Wu Jianhua; Jin Fengtao; Zhao Gang

    2005-01-01

    The electron-impact excitation cross sections at low electron energies have been calculated using a fully relativistic R-matrix method for transitions between levels of 4p 6 , 4p 5 5s, and 4p 5 5p configurations. To ensure the convergence of results, we have paid special attention to the factors that may affect the convergence of cross sections. For examples, we have included extensive configuration interactions in the wave-function expansion of the target states. A large enough R-matrix boundary has been taken to ensure the convergence of atomic wave functions. Contributions to cross sections from a large number of partial waves (up to J=39.5) have been explicitly calculated. The final results are in good agreement with recent experimental data by Jung et al. [Phys. Rev. Lett. 94, 163202 (2005)] after shifting the position of electron energy. The relative difference is about 10% for four transitions out of the metastable levels. The results eliminated the significant discrepancies between theory and experimental work on excitation cross sections out of the metastable levels reported in the literature

  4. Impact of built-in fields and contact configuration on the characteristics of ultra-thin GaAs solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Aeberhard, Urs, E-mail: u.aeberhard@fz-juelich.de [IEK-5 Photovoltaik, Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2016-07-18

    We discuss the effects of built-in fields and contact configuration on the photovoltaic characteristics of ultra-thin GaAs solar cells. The investigation is based on advanced quantum-kinetic simulations reaching beyond the standard semi-classical bulk picture concerning the consideration of charge carrier states and dynamics in complex potential profiles. The thickness dependence of dark and photocurrent in the ultra-scaled regime is related to the corresponding variation of both, the built-in electric fields and associated modification of the density of states, and the optical intensity in the films. Losses in open-circuit voltage and short-circuit current due to the leakage of electronically and optically injected carriers at minority carrier contacts are investigated for different contact configurations including electron and hole blocking barrier layers. The microscopic picture of leakage currents is connected to the effect of finite surface recombination velocities in the semi-classical description, and the impact of these non-classical contact regions on carrier generation and extraction is analyzed.

  5. The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography

    Directory of Open Access Journals (Sweden)

    Toon Van Cauteren

    2017-01-01

    Full Text Available Objectives. To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR techniques on the iodine dose in coronary CTA. Methods. Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR, and contrast-to-noise ratio (CNR in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. Results. Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11, except for streak artifacts (p=0.02 which were considered to be more severe, although acceptable, with the 80 kVp protocol. Conclusions. Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.

  6. Routine gastrostomy tube placement in gastric bypass patients: impact on length of stay and 30-day readmission rate.

    Science.gov (United States)

    Moon, Rena; Teixeira, Andre; Potenza, Kelly; Jawad, Muhammad A

    2013-02-01

    Laparoscopic Roux-en-Y gastric bypass (RYGB) is an effective treatment for morbid obesity. Current average length of hospital stay (LOS) after RYGB is 2-3 days and 30-day readmission rate is 8-13 %. The aim of our study is to evaluate the effect of routine gastrostomy tube placement in perioperative outcomes of RYGB patients. Between January 2008 and December 2010, a total of 840 patients underwent RYGB at our institution. All RYGB patients had gastrostomy tube placed, which was kept for 6 weeks. A retrospective review of a prospectively collected database was performed for all RYGB patients, noting the outcomes and complications of the procedure. Average LOS in our patient population was 1.1 days (range, 1-14 days), and 824 (98.3 %) patients were discharged on postoperative day 1. Readmissions within 30 days after the index RYGB was observed in 31 (3.7 %) patients. Reasons included abdominal pain (n = 14), nausea/vomiting (n = 6), gastrostomy tube-related complications (n = 5), chest pain (n = 3), allergic reaction (n = 1), urinary tract infection (n = 1), and dehydration (n = 1). Of these readmitted patients, nine (1.1 %) patients required reoperations due to small bowel obstruction (n = 5), perforated anastomotic ulcer (n = 1), anastomotic leak (n = 1), subphrenic abscess (n = 1), and appendicitis (n = 1). Routine gastrostomy tube placement in the gastric remnant at the time of RYGB seems to have contributed to our short LOS and low 30-day readmission rate.

  7. Mechanical configuration and maintenance

    International Nuclear Information System (INIS)

    Brown, T.G.; Casini, G.; Churakov, G.F.

    1982-01-01

    The INTOR engineering design has been strongly influenced by considerations for assembly and maintenance. A maintenance philosophy was established at the outset of the conceptual design to insure that the tokamak configuration would be developed to accommodate maintenance requirements. The main features of the INTOR design are summarized in this paper with primary emphasis on the impact of maintenance considerations. The most apparent configuration design feature is the access provided for torus maintenance. Particular attention was given to the size and location of superconducting magnets and the location of vacuum boundaries. All of the poloidal field (PF) coils are placed outside of the bore of the toroidal field (TF) coils and located above and below an access opening between adjacent TF coils through which torus sectors are removed. A magnet structural configuration consisting of mechanically attached reinforcing members has been designed which facilitates the open access space for torus sector removal. For impurity control, a single null poloidal divertor was selected over a double null design in order to maintain sufficient access for pumping and maintenance of the collector. A double null divertor was found to severely limit access to the torus with the addition of divertor collectors and pumping at the top. For this reason, a single null concept was selected in spite of the more difficult design problems associated with the required asymmetric PF system and higher particle loadings

  8. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  9. A nationwide study on the impact of pneumococcal conjugate vaccination on antibiotic use and ventilation tube insertion in Denmark 2000-2014

    DEFF Research Database (Denmark)

    Howitz, Michael Frantz; Harboe, Zitta Barrella; Ingels, Helene

    2017-01-01

    these account for most pneumococcal infections. In this study, we used likely proxies for respiratory infections in children, such as antibiotic use and ventilation tube insertions (VTI), to estimate the impact of the vaccine on a national level. The study was designed as a population-based retrospective...... of antibiotics in the pre-PCV period to a decreasing incidence for all children age 0-15years. The 2.4 DDD per person year in 2014 was at almost the same level of antibiotic use as in 2000 at 2.3 DDD per person year. Similar patterns were observed in the mostly vaccinated age groups below 5years of age. For VTI......Introduction of Pneumococcal Conjugated Vaccines (PCV) in national immunization programs have been successful in reducing the number of invasive and lower respiratory pneumococcal infections. The impact of the vaccines on upper respiratory infections caused by pneumococci is less clear although...

  10. Opposed slant tube diabatic sorber

    Science.gov (United States)

    Erickson, Donald C.

    2004-01-20

    A sorber comprised of at least three concentric coils of tubing contained in a shell with a flow path for liquid sorbent in one direction, a flow path for heat transfer fluid which is in counter-current heat exchange relationship with sorbent flow, a sorbate vapor port in communication with at least one of sorbent inlet or exit ports, wherein each coil is coiled in opposite direction to those coils adjoining it, whereby the opposed slant tube configuration is achieved, with structure for flow modification in the core space inside the innermost coil.

  11. Impact of the configuration of stretching and ocean-atmosphere coupling on tropical cyclone activity in the variable-resolution GCM ARPEGE

    Energy Technology Data Exchange (ETDEWEB)

    Daloz, Anne Sophie; Chauvin, Fabrice [CNRM-GAME, Groupe de Modelisation Grande Echelle et Climat, Toulouse Cedex 1 (France); Roux, Frank [Universite de Toulouse, Laboratoire d' Aerologie, Centre National de la Recherche Scientifique, Toulouse (France)

    2012-11-15

    This study starts by investigating the impact of the configuration of the variable-resolution atmospheric grid on tropical cyclone (TC) activity. The French atmospheric general circulation model ARPEGE, the grid of which is rotated and stretched over the North Atlantic basin, was used with prescribed sea surface temperatures. The study clearly shows that changing the position of the stretching pole strongly modifies the representation of TC activity over the North Atlantic basin. A pole in the centre of the North Atlantic basin provides the best representation of the TC activity for this region. In a second part, the variable-resolution climate model ARPEGE is coupled with the European oceanic global climate model NEMO in order to study the impact of ocean-atmosphere coupling on TC activity over the North Atlantic basin. Two pre-industrial runs, a coupled simulation and a simulation forced by the sea surface temperatures from the coupled one, are compared. The results show that the coupled simulation is more active in the Caribbean Sea and the Gulf of Mexico while the forced simulation is more active over eastern Florida and the eastern Atlantic. The difference in the distribution of TC activity is certainly linked with the location of TC genesis. In the forced simulation, tropical cyclogenesis is closer to the west African coast than in the coupled simulation. Moreover, the difference in TC activity over the eastern Atlantic seems to be related to two different mechanisms: the difference in African easterly wave activity over the west of Africa and the cooling produced, in the coupled simulation, by African easterly waves over the eastern Atlantic. Finally, the last part studies the impact of changing the frequency of ocean-atmosphere coupling on Atlantic TC activity. Increasing the frequency of coupling decreases the density of TC activity over the North Atlantic basin. However, it does not modify the spatial distribution of the TC activity. TC rainfalls are

  12. Impact of the configuration of stretching and ocean-atmosphere coupling on tropical cyclone activity in the variable-resolution GCM ARPEGE

    Science.gov (United States)

    Daloz, Anne Sophie; Chauvin, Fabrice; Roux, Frank

    2012-11-01

    This study starts by investigating the impact of the configuration of the variable-resolution atmospheric grid on tropical cyclone (TC) activity. The French atmospheric general circulation model ARPEGE, the grid of which is rotated and stretched over the North Atlantic basin, was used with prescribed sea surface temperatures. The study clearly shows that changing the position of the stretching pole strongly modifies the representation of TC activity over the North Atlantic basin. A pole in the centre of the North Atlantic basin provides the best representation of the TC activity for this region. In a second part, the variable-resolution climate model ARPEGE is coupled with the European oceanic global climate model NEMO in order to study the impact of ocean-atmosphere coupling on TC activity over the North Atlantic basin. Two pre-industrial runs, a coupled simulation and a simulation forced by the sea surface temperatures from the coupled one, are compared. The results show that the coupled simulation is more active in the Caribbean Sea and the Gulf of Mexico while the forced simulation is more active over eastern Florida and the eastern Atlantic. The difference in the distribution of TC activity is certainly linked with the location of TC genesis. In the forced simulation, tropical cyclogenesis is closer to the west African coast than in the coupled simulation. Moreover, the difference in TC activity over the eastern Atlantic seems to be related to two different mechanisms: the difference in African easterly wave activity over the west of Africa and the cooling produced, in the coupled simulation, by African easterly waves over the eastern Atlantic. Finally, the last part studies the impact of changing the frequency of ocean-atmosphere coupling on Atlantic TC activity. Increasing the frequency of coupling decreases the density of TC activity over the North Atlantic basin. However, it does not modify the spatial distribution of the TC activity. TC rainfalls are

  13. Ocean acidification impacts spine integrity but not regenerative capacity of spines and tube feet in adult sea urchins.

    Science.gov (United States)

    Emerson, Chloe E; Reinardy, Helena C; Bates, Nicholas R; Bodnar, Andrea G

    2017-05-01

    Increasing atmospheric carbon dioxide (CO 2 ) has resulted in a change in seawater chemistry and lowering of pH, referred to as ocean acidification. Understanding how different organisms and processes respond to ocean acidification is vital to predict how marine ecosystems will be altered under future scenarios of continued environmental change. Regenerative processes involving biomineralization in marine calcifiers such as sea urchins are predicted to be especially vulnerable. In this study, the effect of ocean acidification on regeneration of external appendages (spines and tube feet) was investigated in the sea urchin Lytechinus variegatus exposed to ambient (546 µatm), intermediate (1027 µatm) and high (1841 µatm) partial pressure of CO 2 ( p CO 2 ) for eight weeks. The rate of regeneration was maintained in spines and tube feet throughout two periods of amputation and regrowth under conditions of elevated p CO 2 . Increased expression of several biomineralization-related genes indicated molecular compensatory mechanisms; however, the structural integrity of both regenerating and homeostatic spines was compromised in high p CO 2 conditions. Indicators of physiological fitness (righting response, growth rate, coelomocyte concentration and composition) were not affected by increasing p CO 2 , but compromised spine integrity is likely to have negative consequences for defence capabilities and therefore survival of these ecologically and economically important organisms.

  14. Ocean acidification impacts spine integrity but not regenerative capacity of spines and tube feet in adult sea urchins

    Science.gov (United States)

    Emerson, Chloe E.; Reinardy, Helena C.; Bates, Nicholas R.

    2017-01-01

    Increasing atmospheric carbon dioxide (CO2) has resulted in a change in seawater chemistry and lowering of pH, referred to as ocean acidification. Understanding how different organisms and processes respond to ocean acidification is vital to predict how marine ecosystems will be altered under future scenarios of continued environmental change. Regenerative processes involving biomineralization in marine calcifiers such as sea urchins are predicted to be especially vulnerable. In this study, the effect of ocean acidification on regeneration of external appendages (spines and tube feet) was investigated in the sea urchin Lytechinus variegatus exposed to ambient (546 µatm), intermediate (1027 µatm) and high (1841 µatm) partial pressure of CO2 (pCO2) for eight weeks. The rate of regeneration was maintained in spines and tube feet throughout two periods of amputation and regrowth under conditions of elevated pCO2. Increased expression of several biomineralization-related genes indicated molecular compensatory mechanisms; however, the structural integrity of both regenerating and homeostatic spines was compromised in high pCO2 conditions. Indicators of physiological fitness (righting response, growth rate, coelomocyte concentration and composition) were not affected by increasing pCO2, but compromised spine integrity is likely to have negative consequences for defence capabilities and therefore survival of these ecologically and economically important organisms. PMID:28573022

  15. Neutron tubes

    Science.gov (United States)

    Leung, Ka-Ngo [Hercules, CA; Lou, Tak Pui [Berkeley, CA; Reijonen, Jani [Oakland, CA

    2008-03-11

    A neutron tube or generator is based on a RF driven plasma ion source having a quartz or other chamber surrounded by an external RF antenna. A deuterium or mixed deuterium/tritium (or even just a tritium) plasma is generated in the chamber and D or D/T (or T) ions are extracted from the plasma. A neutron generating target is positioned so that the ion beam is incident thereon and loads the target. Incident ions cause D-D or D-T (or T-T) reactions which generate neutrons. Various embodiments differ primarily in size of the chamber and position and shape of the neutron generating target. Some neutron generators are small enough for implantation in the body. The target may be at the end of a catheter-like drift tube. The target may have a tapered or conical surface to increase target surface area.

  16. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants—the impact of ventilator settings on tracheal pressure swings

    International Nuclear Information System (INIS)

    Hentschel, Roland; Buntzel, Julia; Guttmann, Josef; Schumann, Stefan

    2011-01-01

    Resistive properties of endotracheal tubes (ETTs) are particularly relevant in newborns and small infants who are generally ventilated through ETTs with a small inner diameter. The ventilation rate is also high and the inspiratory time (ti) is short. These conditions effectuate high airway flows with excessive flow acceleration, so airway resistance and inertance play an important role. We carried out a model study to investigate the impact of varying ETT size, lung compliance and ventilator settings, such as peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and inspiratory time (ti) on the pressure–flow characteristics with respect to the resistive and inertive properties of the ETT. Pressure at the Y piece was compared to direct measurement of intratracheal pressure (P trach ) at the tip of the ETT, and pressure drop (ΔP ETT ) was calculated. Applying published tube coefficients (Rohrer's constants and inertance), P trach was calculated from ventilator readings and compared to measured P trach using the root-mean-square error. The most relevant for ΔP ETT was the ETT size, followed by (in descending order) PIP, compliance, ti and PEEP, with gas flow velocity being the principle in common for all these parameters. Depending on the ventilator settings ΔP ETT exceeded 8 mbar in the smallest 2.0 mm ETT. Consideration of inertance as an additional effect in this setting yielded a better agreement of calculated versus measured P trach than Rohrer's constants alone. We speculate that exact tracheal pressure tracings calculated from ventilator readings by applying Rohrer's equation and the inertance determination to small size ETTs would be helpful. As an integral part of ventilator software this would (1) allow an estimate of work of breathing and implementation of an automatic tube compensation, and (2) be important for gentle ventilation in respiratory care, especially of small infants, since it enables the physician to

  17. Software configuration management

    International Nuclear Information System (INIS)

    Arribas Peces, E.; Martin Faraldo, P.

    1993-01-01

    Software Configuration Management is directed towards identifying system configuration at specific points of its life cycle, so as to control changes to the configuration and to maintain the integrity and traceability of the configuration throughout its life. SCM functions and tasks are presented in the paper

  18. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  19. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  20. Investigation of material efficient fin patterns for cost-effective operation of fin and tube heat exchanger

    DEFF Research Database (Denmark)

    Singh, Shobhana; Sørensen, Kim; Condra, Thomas Joseph

    2017-01-01

    and tube heat exchanger. Computational fluid dynamic models of fin and tube heat exchanger with different fin patterns are developed to investigate the fin pattern behavior on heat transfer and pressure loss performance data. In addition, the numerical results are utilized to analyze the engineering design......Design management of a thermal energy system is a critical part of identifying basic designs that meet large scale user demand under certain operating characteristics. Fin and tube heat exchangers are among the most commonly used thermal energy systems which are generating considerable interest...... scale-up heat exchanger configurations with each fin pattern focusing on the application of chosen fin and tube heat exchanger in marine exhaust gas boiler. The analysis highlights the impact of material efficient fin patterns investigated and predicts that the polynomial and sinusoidal fin patterns...

  1. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  2. A unix configuration engine

    International Nuclear Information System (INIS)

    Burgess, M.

    1994-06-01

    A high level description language is presented for the purpose of automatically configuring large heterogeneous networked unix environments, based on class-oriented abstractions. The configuration engine is portable and easily extensible

  3. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  4. Impact of Cutting Forces and Chip Microstructure in High Speed Machining of Carbon Fiber – Epoxy Composite Tube

    Directory of Open Access Journals (Sweden)

    Roy Y. Allwin

    2017-09-01

    Full Text Available Carbon fiber reinforced polymeric (CFRP composite materials are widely used in aerospace, automobile and biomedical industries due to their high strength to weight ratio, corrosion resistance and durability. High speed machining (HSM of CFRP material is needed to study the impact of cutting parameters on cutting forces and chip microstructure which offer vital inputs to the machinability and deformation characteristics of the material. In this work, the orthogonal machining of CFRP was conducted by varying the cutting parameters such as cutting speed and feed rate at high cutting speed/feed rate ranges up to 346 m/min/ 0.446 mm/rev. The impact of the cutting parameters on cutting forces (principal cutting, feed and thrust forces and chip microstructure were analyzed. A significant impact on thrust forces and chip segmentation pattern was seen at higher feed rates and low cutting speeds.

  5. Spring/dimple instrument tube restraint

    Science.gov (United States)

    DeMario, E.E.; Lawson, C.N.

    1993-11-23

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures.

  6. Observed benefits from product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Haug, Anders; Mortensen, Niels Henrik

    2013-01-01

    This article presents a study of the benefits obtained from applying product configuration systems based on a case study in four industry companies. The impacts are described according to main objectives in literature for imple-menting product configuration systems: lead time in the specification...... affected by the use of product configu-ration systems e.g. increased sales, decrease in the number of SKU's, improved ability to introduce new products, and cost reductions....

  7. HLT configuration management system

    CERN Document Server

    Daponte, Vincenzo

    2015-01-01

    The CMS High Level Trigger (HLT) is implemented running a streamlined version of the CMS offline reconstruction software running on thousands of CPUs. The CMS software is written mostly in C++, using Python as its configuration language through an embedded CPython interpreter. The configuration of each process is made up of hundreds of modules, organized in sequences and paths. As an example, the HLT configurations used for 2011 data taking comprised over 2200 different modules, organized in more than 400 independent trigger paths. The complexity of the HLT configurations and the large number of configuration produced require the design of a suitable data management system. The present work describes the designed solution to manage the considerable number of configurations developed and to assist the editing of new configurations. The system is required to be remotely accessible and OS-independent as well as easly maintainable easy to use. To meet these requirements a three-layers architecture has been choose...

  8. Conceptualizing Embedded Configuration

    DEFF Research Database (Denmark)

    Oddsson, Gudmundur Valur; Hvam, Lars; Lysgaard, Ole

    2006-01-01

    Installing and servicing complex electromechanical systems is more tedious than is necessary. By putting the product knowledge into the product itself, which then would allow automation in constructing the product from modules, could solve that. It would support personnel in aftersales installation...... and services. The general idea can be named embedded configuration. In this article we intend to conceptualize embedded configuration, what it is and is not. The difference between embedded configuration, sales configuration and embedded software is explained. We will look at what is needed to make embedded...... configuration systems. That will include requirements to product modelling techniques. An example with consumer electronics will illuminate the elements of embedded configuration in settings that most can relate to. The question of where embedded configuration would be relevant is discussed, and the current...

  9. Tracheostomy tube - eating

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000464.htm Tracheostomy tube - eating To use the sharing features on ... when you swallow foods or liquids. Eating and Tracheostomy Tubes When you get your tracheostomy tube, or ...

  10. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  11. Heat exchanger tube mounts

    Science.gov (United States)

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  12. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  13. Impacto ecológico de los Intercambiadores de calor de tubo y coraza; Ecological impact of Shell and tube heat exchangers

    Directory of Open Access Journals (Sweden)

    Maida Bárbara Reyes Rodríguez

    2015-04-01

    Full Text Available Los intercambiadores de calor de tubo y coraza son de los equipos más importantes en la industria. Su diseño termodinámico se basa en el coeficiente global de transferencia de calor y la caída de presión total. En 2007 se estableció una nueva propiedad termodinámica denominada “Entransía”, que expresa la capacidad de un cuerpo de transferir calor. A la pérdida de esa capacidad se le denomina “Disipación de Entransía”. Para evaluar el impacto ecológico de las máquinas térmicas, Angulo-Brown creó en 1991 la llamada función ecológica. En el presente trabajo se combinó la disipación de entransía con la función ecológica y se creó una nueva expresión para evaluar el impacto ambiental de los intercambiadores de calor. Se realizó además la optimización muti-objetivo de estos equipos. Fueron utilizadas como funciones objetivo la función ecológica y el costo. Para realizar la optimización se utilizó el método de los Algoritmos Genéticos.Shell and tube heat exchangers are ones the most important equipment in the industry. Their thermodynamic design is based on the global heat transference coefficient and the pressure drop. In 2007 was settled a new thermodynamic property denominated “Entransy”, which expresses the capacity of a body to transfer heat. The loss of this capacity is denominated “Entransy Dissipation”. For evaluating the ecological impact of thermal machines, Angulo-Brown created in 1991 the “ecological function”. In this paper the“entransy dissipation” and the ecological function were combined and a new expression for evaluating the ecological impact of shell and tube heat exchangers was created. A multi-objective optimization of this equipment wasalso realized. The ecological function and the cost wereused as objective functions. For carry out the optimization the method of the Genetic Algorithms was used.

  14. Software configuration management

    CERN Document Server

    Keyes, Jessica

    2004-01-01

    Software Configuration Management discusses the framework from a standards viewpoint, using the original DoD MIL-STD-973 and EIA-649 standards to describe the elements of configuration management within a software engineering perspective. Divided into two parts, the first section is composed of 14 chapters that explain every facet of configuration management related to software engineering. The second section consists of 25 appendices that contain many valuable real world CM templates.

  15. CONFIGURATION GENERATOR MODEL

    Energy Technology Data Exchange (ETDEWEB)

    A. Alsaed

    2004-11-18

    ''The Disposal Criticality Analysis Methodology Topical Report'' prescribes an approach to the methodology for performing postclosure criticality analyses within the monitored geologic repository at Yucca Mountain, Nevada. An essential component of the methodology is the ''Configuration Generator Model for In-Package Criticality'' that provides a tool to evaluate the probabilities of degraded configurations achieving a critical state. The configuration generator model is a risk-informed, performance-based process for evaluating the criticality potential of degraded configurations in the monitored geologic repository. The method uses event tree methods to define configuration classes derived from criticality scenarios and to identify configuration class characteristics (parameters, ranges, etc.). The probabilities of achieving the various configuration classes are derived in part from probability density functions for degradation parameters. The NRC has issued ''Safety Evaluation Report for Disposal Criticality Analysis Methodology Topical Report, Revision 0''. That report contained 28 open items that required resolution through additional documentation. Of the 28 open items, numbers 5, 6, 9, 10, 18, and 19 were concerned with a previously proposed software approach to the configuration generator methodology and, in particular, the k{sub eff} regression analysis associated with the methodology. However, the use of a k{sub eff} regression analysis is not part of the current configuration generator methodology and, thus, the referenced open items are no longer considered applicable and will not be further addressed.

  16. Configuration management at NEK

    International Nuclear Information System (INIS)

    Podhraski, M.

    1999-01-01

    Configuration Management (CM) objectives at NEK are to ensure consistency between Design Requirements, Physical Plant Configuration and Configuration Information. Software applications, supporting Design Change, Work Control and Document Control Processes, are integrated in one module-oriented Management Information System (MIS). Master Equipment Component List (MECL) database is central MIS module. Through a combination of centralized database and process migrated activities it is ensured that the CM principles and requirements (accurate, current design data matching plant's physical configuration while complying to applicable requirements), are followed and fulfilled.(author)

  17. Simulator configuration management system

    International Nuclear Information System (INIS)

    Faulent, J.; Brooks, J.G.

    1990-01-01

    The proposed revisions to ANS 3.5-1985 (Section 5) require Utilities to establish a simulator Configuration Management System (CMS). The proposed CMS must be capable of: Establishing and maintaining a simulator design database. Identifying and documenting differences between the simulator and its reference plant. Tracking the resolution of identified differences. Recording data to support simulator certification, testing and maintenance. This paper discusses a CMS capable of meeting the proposed requirements contained in ANS 3.5. The system will utilize a personal computer and a relational database management software to construct a simulator design database. The database will contain records to all reference nuclear plant data used in designing the simulator, as well as records identifying all the software, hardware and documentation making up the simulator. Using the relational powers of the database management software, reports will be generated identifying the impact of reference plant changes on the operation of the simulator. These reports can then be evaluated in terms of training needs to determine if changes are required for the simulator. If a change is authorized, the CMS will track the change through to its resolution and then incorporate the change into the simulator design database

  18. Experimental investigation of the vibration response of a flexible tube due to simulated reactor core, cross and annular exit flows

    International Nuclear Information System (INIS)

    Haslinger, K.H.; Martin, M.L.; Higgins, W.H.; Rossano, F.V.

    1989-01-01

    Instrumentation tubes in pressurized nuclear reactors have experienced wear due to excessive flow-induced vibrations. Experiments to identify the predominant flow excitation mechanism at a particular plant, and to develop a sleeve design to remedy the wear problem are reported. An instrumented flow visualization model enabled simulation of a wide range of individual or combined reactor core flow, cross flow and thimble flow conditions. The instrumentation scheme adopted for these experiments used proximity displacement transducers and a force transducer to measure respectively tube motion and contact/impact forces at the wear region. Extensive testing of the original, in-plant configuration identified the normal core flow as the primary source of excitation. Shielding the In-Core-Instrumentation thimble tube from the normal core flow curtailed vibration amplitudes; however, thimble flow excitation then became more pronounced. Various outlet nozzle configurations were investigated. An internal cavity combined with radial outlet slots became the optimum solution for the problem. The paper presents typical test data in the form of orbital tube motion, spectrum analysis and time history collages. The effectiveness of shielding the instrumentation tube from the flow is demonstrated. (author)

  19. A nationwide study on the impact of pneumococcal conjugate vaccination on antibiotic use and ventilation tube insertion in Denmark 2000-2014.

    Science.gov (United States)

    Howitz, Michael Frantz; Harboe, Zitta Barrella; Ingels, Helene; Valentiner-Branth, Palle; Mølbak, Kåre; Djurhuus, Bjarki Ditlev

    2017-10-13

    Introduction of Pneumococcal Conjugated Vaccines (PCV) in national immunization programs have been successful in reducing the number of invasive and lower respiratory pneumococcal infections. The impact of the vaccines on upper respiratory infections caused by pneumococci is less clear although these account for most pneumococcal infections. In this study, we used likely proxies for respiratory infections in children, such as antibiotic use and ventilation tube insertions (VTI), to estimate the impact of the vaccine on a national level. The study was designed as a population-based retrospective observational study, comparing trends in the incidence rate of antibiotic prescriptions and VTIs in the period 2000-2014, where PCV7 was introduced in 2007 and PCV13 in 2010. The introduction of PCV7 and PCV13 correlated with changes in the incidence rate from an almost steady increase in prescription of antibiotics in the pre-PCV period to a decreasing incidence for all children age 0-15years. The 2.4 DDD per person year in 2014 was at almost the same level of antibiotic use as in 2000 at 2.3 DDD per person year. Similar patterns were observed in the mostly vaccinated age groups below 5years of age. For VTI we observed a decreasing incidence rate in the years following introduction of PCV13 ending with a slightly higher incidence at 35 per 1000 person years in 2014 compared to 31 in year 2000. We conclude that the steady increase in antibiotic use and VTI in the pre-PCV period have been partially reversed to near year 2000 levels after the introduction of PCV. This indicates that implementation of pneumococcal vaccines in the Childhood Vaccination Programme has likely reduced the incidence of upper respiratory diseases due to pneumococci in Denmark. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. PIV Logon Configuration Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Glen Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-04

    This document details the configurations and enhancements implemented to support the usage of federal Personal Identity Verification (PIV) Card for logon on unclassified networks. The guidance is a reference implementation of the configurations and enhancements deployed at the Los Alamos National Laboratory (LANL) by Network and Infrastructure Engineering – Core Services (NIE-CS).

  1. Global Value Chain Configuration

    DEFF Research Database (Denmark)

    Hernandez, Virginia; Pedersen, Torben

    2017-01-01

    This paper reviews the literature on global value chain configuration, providing an overview of this topic. Specifically, we review the literature focusing on the concept of the global value chain and its activities, the decisions involved in its configuration, such as location, the governance mo...

  2. Simulator configuration maintenance

    International Nuclear Information System (INIS)

    2006-01-01

    Requirements and recommendations of this section defines NPP personnel activity aimed to the provision of the simulator configuration compliance with the current configuration of the power-generating unit-prototype, standard and technical requirements and describe a monitoring procedure for a set of simulator software and hardware, training, organizational and technical documents

  3. Risk-based configuration control

    International Nuclear Information System (INIS)

    Szikszai, T.

    1997-01-01

    The presentation discusses the following issues: The Configuration Control; The Risk-based Configuration Control (during power operation mode, and during shutdown mode). PSA requirements. Use of Risk-based Configuration Control System. Configuration Management (basic elements, benefits, information requirements)

  4. Business Model Process Configurations

    DEFF Research Database (Denmark)

    Taran, Yariv; Nielsen, Christian; Thomsen, Peter

    2015-01-01

    strategic preference, as part of their business model innovation activity planned. Practical implications – This paper aimed at strengthening researchers and, particularly, practitioner’s perspectives into the field of business model process configurations. By insuring an [abstracted] alignment between......Purpose – The paper aims: 1) To develop systematically a structural list of various business model process configuration and to group (deductively) these selected configurations in a structured typological categorization list. 2) To facilitate companies in the process of BM innovation......, by developing (inductively) an ontological classification framework, in view of the BM process configurations typology developed. Design/methodology/approach – Given the inconsistencies found in the business model studies (e.g. definitions, configurations, classifications) we adopted the analytical induction...

  5. A modeling investigation of the impact of street and building configurations on personal air pollutant exposure in isolated deep urban canyons.

    Science.gov (United States)

    Ng, Wai-Yin; Chau, Chi-Kwan

    2014-01-15

    This study evaluated the effectiveness of different configurations for two building design elements, namely building permeability and setback, proposed for mitigating air pollutant exposure problems in isolated deep canyons by using an indirect exposure approach. The indirect approach predicted the exposures of three different population subgroups (i.e. pedestrians, shop vendors and residents) by multiplying the pollutant concentrations with the duration of exposure within a specific micro-environment. In this study, the pollutant concentrations for different configurations were predicted using a computational fluid dynamics model. The model was constructed based on the Reynolds-Averaged Navier-Stokes (RANS) equations with the standard k-ε turbulence model. Fifty-one canyon configurations with aspect ratios of 2, 4, 6 and different building permeability values (ratio of building spacing to the building façade length) or different types of building setback (recess of a high building from the road) were examined. The findings indicated that personal exposures of shop vendors were extremely high if they were present inside a canyon without any setback or separation between buildings and when the prevailing wind was perpendicular to the canyon axis. Building separation and building setbacks were effective in reducing personal air exposures in canyons with perpendicular wind, although their effectiveness varied with different configurations. Increasing the permeability value from 0 to 10% significantly lowered the personal exposures on the different population subgroups. Likewise, the personal exposures could also be reduced by the introduction of building setbacks despite their effects being strongly influenced by the aspect ratio of a canyon. Equivalent findings were observed if the reduction in the total development floor area (the total floor area permitted to be developed within a particular site area) was also considered. These findings were employed to

  6. Impact of steel slag on the ammonium adsorption by zeolite and a new configuration of zeolite-steel slag substrate for constructed wetlands.

    Science.gov (United States)

    Shi, Pengbo; Jiang, Yingbo; Zhu, Hongtao; Sun, Dezhi

    2017-07-01

    The CaO dissolution from slag, as well as the effects of influencing parameters (i.e. pH and Ca 2+ concentration) on the ammonium adsorption onto zeolite, was systematically studied in this paper. Modeling results of Ca 2+ and OH - release from slag indicated that pseudo-second-order reaction had a better fitness than pseudo-first-order reaction. Changing pH value from 7 to 12 resulted in a drastic reduction of the ammonium adsorption capacity on zeolite, from the peak adsorption capacity at pH 7. High Ca 2+ concentration in solution also inhibited the adsorption of ammonium onto zeolite. There are two proposed mechanisms for steel slag inhibiting the ammonium adsorption capacity of zeolite. On the one hand, OH - released from steel slag can react with ammonium ions to produce the molecular form of ammonia (NH 3 ·H 2 O), which would cause the dissociation of NH 4 + from zeolite. On the other hand, Ca 2+ could replace the NH 4 + ions to adhere onto the surface of zeolite. An innovative substrate filling configuration with zeolite placed upstream of the steel slag was then proposed to eliminate the disadvantageous effects of steel slag. Experimental results showed that this novel filling configuration was superior to two other filling configurations in terms of ammonium removal.

  7. System and method having multi-tube fuel nozzle with differential flow

    Science.gov (United States)

    Hughes, Michael John; Johnson, Thomas Edward; Berry, Jonathan Dwight; York, William David

    2017-01-03

    A system includes a multi-tube fuel nozzle with a fuel nozzle body and a plurality of tubes. The fuel nozzle body includes a nozzle wall surrounding a chamber. The plurality of tubes extend through the chamber, wherein each tube of the plurality of tubes includes an air intake portion, a fuel intake portion, and an air-fuel mixture outlet portion. The multi-tube fuel nozzle also includes a differential configuration of the air intake portions among the plurality of tubes.

  8. Flux Tube Dynamics in the Dual Superconductor

    International Nuclear Information System (INIS)

    Lampert, M.; Svetitsky, B.

    1999-01-01

    We have studied plasma oscillations in a flux tube created in a dual superconductor. The theory contains an Abelian gauge field coupled magnetically to a Higgs field that confines electric charge via the dual Meissner effect. Starting from a static flux tube configuration, with electric charges at either end, we release a fluid of electric charges in the system that accelerate and screen the electric field. The weakening of the electric field allows the flux tube to collapse, and the inertia of the charges forces it open again. We investigate both Type I and Type II superconductors, with plasma frequencies both above and below the threshold for radiation into the Higgs vacuum. (The parameters appropriate to QCD are in the Type II regime; the plasma frequency depends on the mass taken for the fluid constituents.) The coupling of the plasma oscillations to the Higgs field making up the flux tube is the main new feature in our work

  9. Inverse Kinematics of Concentric Tube Steerable Needles.

    Science.gov (United States)

    Sears, Patrick; Dupont, Pierre E

    2007-01-01

    Prior papers have introduced steerable needles composed of precurved concentric tubes. The curvature and extent of these needles can be controlled by the relative rotation and translation of the individual tubes. Under certain assumptions on the geometry and design of these needles, the forward kinematics problem can be solved in closed form by means of algebraic equations. The inverse kinematics problem, however, is not as straightforward owing to the nonlinear map between relative tube displacements and needle tip configuration as well as to the multiplicity of solutions as the number of tubes increases. This paper presents a general approach to solving the inverse kinematics problem using a pseudoinverse solution together with gradients of nullspace potential functions to enforce geometric and mechanical constraints.

  10. Configuration by Modularisation

    DEFF Research Database (Denmark)

    Riitahuhta, Asko; Andreasen, Mogens Myrup

    1998-01-01

    Globally operating companies have realized that locally customized products and services are today the prerequisite for the success. The capability or the paradigm to act locally in global markets is called Mass Customization [Victor 1997]. The prerequisite for Mass Customization is Configuration...... Management and i Configuration Management the most important means is Modularisation.The goal of this paper is to show Configuration Management as a contribution to the Mass Customisation and Modularisation as a contribution to the industrialisation of the design area [Andreasen 1997]. A basic model...

  11. Global Value Chain Configuration

    DEFF Research Database (Denmark)

    Hernandez, Virginia; Pedersen, Torben

    2017-01-01

    This paper reviews the literature on global value chain configuration, providing an overview of this topic. Specifically, we review the literature focusing on the concept of the global value chain and its activities, the decisions involved in its configuration, such as location, the governance...... modes chosen and the different ways of coordinating them. We also examine the outcomes of a global value chain configuration in terms of performance and upgrading. Our aim is to review the state of the art of these issues, identify research gaps and suggest new lines for future research that would...

  12. Drupal 8 configuration management

    CERN Document Server

    Borchert, Stefan

    2015-01-01

    Drupal 8 Configuration Management is intended for people who use Drupal 8 to build websites, whether you are a hobbyist using Drupal for the first time, a long-time Drupal site builder, or a professional web developer.

  13. Configuration Management Automation (CMA) -

    Data.gov (United States)

    Department of Transportation — Configuration Management Automation (CMA) will provide an automated, integrated enterprise solution to support CM of FAA NAS and Non-NAS assets and investments. CMA...

  14. Computer software configuration management

    International Nuclear Information System (INIS)

    Pelletier, G.

    1987-08-01

    This report reviews the basic elements of software configuration management (SCM) as defined by military and industry standards. Several software configuration management standards are evaluated given the requirements of the nuclear industry. A survey is included of available automated tools for supporting SCM activities. Some information is given on the experience of establishing and using SCM plans of other organizations that manage critical software. The report concludes with recommendations of practices that would be most appropriate for the nuclear power industry in Canada

  15. Resonant oscillations in open axisymmetric tubes

    Science.gov (United States)

    Amundsen, D. E.; Mortell, M. P.; Seymour, B. R.

    2017-12-01

    We study the behaviour of the isentropic flow of a gas in both a straight tube of constant cross section and a cone, open at one end and forced at or near resonance at the other. A continuous transition between these configurations is provided through the introduction of a geometric parameter k associated with the opening angle of the cone where the tube corresponds to k=0. The primary objective is to find long-time resonant and near-resonant approximate solutions for the open tube, i.e. k→ 0. Detailed analysis for both the tube and cone in the limit of small forcing (O(ɛ 3)) is carried out, where ɛ 3 is the Mach number of the forcing function and the resulting flow has Mach number O(ɛ ). The resulting approximate solutions are compared with full numerical simulations. Interesting distinctions between the cone and the tube emerge. Depending on the damping and detuning, the responses for the tube are continuous and of O(ɛ ). In the case of the cone, the resonant response involves an amplification of the fundamental resonant mode, usually called the dominant first-mode approximation. However, higher modes must be included for the tube to account for the nonlinear generation of higher-order resonances. Bridging these distinct solution behaviours is a transition layer of O(ɛ 2) in k. It is found that an appropriately truncated set of modes provides the requisite modal approximation, again comparing well to numerical simulations.

  16. Tracheostomy tube - speaking

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000465.htm Tracheostomy tube - speaking To use the sharing features on ... are even speaking devices that can help you. Tracheostomy Tubes and Speaking Air passing through vocal cords ( ...

  17. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  18. Neural Tube Defects

    Science.gov (United States)

    Neural tube defects are birth defects of the brain, spine, or spinal cord. They happen in the ... that she is pregnant. The two most common neural tube defects are spina bifida and anencephaly. In ...

  19. Jejunostomy feeding tube

    Science.gov (United States)

    ... may replace the tube every now and then. Cleaning the Skin Around the J-tube To clean ... this important distinction for online health information and services. Learn more about A.D.A.M.'s editorial ...

  20. Impact of the whole-cell patch-clamp configuration on the pharmacological assessment of the hERG channel: trazodone as a case example.

    Science.gov (United States)

    Rodriguez-Menchaca, Aldo A; Ferrer, Tania; Navarro-Polanco, Ricardo A; Sanchez-Chapula, Jose A; Moreno-Galindo, Eloy G

    2014-01-01

    Voltage- and state-dependent blocks are important mechanisms by which drugs affect voltage-gated ionic channels. However, spontaneous (i.e. drug-free) time-dependent changes in the activation and inactivation of hERG and Na(+) channels have been reported when using conventional whole-cell patch-clamp in HEK-293 cells. hERG channels were heterologously expressed in HEK-293 cells and in Xenopus laevis oocytes. hERG current (IhERG) was recorded using both conventional and perforated whole-cell patch-clamp (HEK-293 cells), and two microelectrode voltage-clamp (Xenopus oocytes) in drug-free solution, and in the presence of the drug trazodone. In conventional whole-cell setup, we observed a spontaneous time-dependent hyperpolarizing shift in the activation curve of IhERG. Conversely, in perforated patch whole-cell (HEK-293 cells) or in two microelectrode voltage-clamp (Xenopus oocytes) activation curves of IhERG were very stable for periods ~50min. Voltage-dependent inactivation of IhERG was not significantly altered in the three voltage clamp configurations tested. When comparing voltage- and state-dependent effects of the antidepressant drug trazodone on IhERG, similar changes between the three voltage clamp configurations were observed as under drug-free conditions. The comparative analysis performed in this work showed that only under conventional whole-cell voltage-clamp conditions, a leftward shift in the activation curve of IhERG occurred, both in the presence and absence of drugs. These spontaneous time-dependent changes in the voltage activation gate of IhERG are a potential confounder in pharmacological studies on hERG channels expressed in HEK-293 cells. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Nasogastric and feeding tubes.

    Science.gov (United States)

    Gharib, Ahmed M; Stern, Eric J; Sherbin, Vandy L; Rohrmann, Charles A

    1996-05-01

    Preview The authors' experience in a radiology department suggested to them that there is a wide range of beliefs among practitioners regarding proper placement of nasogastric and feeding tubes. Improper positioning can cause serious problems, as they explain. Indications for different tube positions, complications of incorrect tube placement, and directions for proper positioning are discussed and illustrated.

  2. Coiled sheet metal strip opens into tubular configuration

    Science.gov (United States)

    Park, J. J.

    1966-01-01

    Copper alloy is converted into a spring material that can be rolled into a compact coil which will spontaneously open to form a tube in the long direction of the strip. The copper alloy is passed through a furnace at a prescribed temperature while restraining the strip in the desired tubular configuration.

  3. The LHCb configuration database

    CERN Document Server

    Abadie, L; Van Herwijnen, Eric; Jacobsson, R; Jost, B; Neufeld, N

    2005-01-01

    The aim of the LHCb configuration database is to store information about all the controllable devices of the detector. The experiment's control system (that uses PVSS ) will configure, start up and monitor the detector from the information in the configuration database. The database will contain devices with their properties, connectivity and hierarchy. The ability to store and rapidly retrieve huge amounts of data, and the navigability between devices are important requirements. We have collected use cases to ensure the completeness of the design. Using the entity relationship modelling technique we describe the use cases as classes with attributes and links. We designed the schema for the tables using relational diagrams. This methodology has been applied to the TFC (switches) and DAQ system. Other parts of the detector will follow later. The database has been implemented using Oracle to benefit from central CERN database support. The project also foresees the creation of tools to populate, maintain, and co...

  4. Configuration Control Office

    CERN Multimedia

    Beltramello, O

    In order to enable Technical Coordination to manage the detector configuration and to be aware of all changes in this configuration, a baseline of the envelopes has been created in April 2001. Fifteen system and multi-system envelope drawings have been approved and baselined. An EDMS file is associated with each approved envelope, which provides a list of the current known unsolved conflicts related to the envelope and a list of remaining drawing inconsistencies to be corrected. The envelope status with the associated drawings and EDMS file can be found on the web at this adress: http://atlasinfo.cern.ch/Atlas/TCOORD/Activities/Installation/Configuration/ Any modification in the baseline has to be requested via the Engineering Change Requests. The procedure can be found under: http://atlasinfo.cern.ch/Atlas/TCOORD/Activities/TcOffice/Quality/ECR/ TC will review all the systems envelopes in the near future and manage conflict resolution with the collaboration of the systems.

  5. Impact of X-ray tube settings and metallic leads on neurological PET imaging when using CT-based attenuation correction

    Science.gov (United States)

    Reza Ay, Mohammad; Zaidi, Habib

    2007-02-01

    The use of X-ray CT images for CT-based attenuation correction (CTAC) of PET data results in the decrease of overall scanning time and creates a noise-free attenuation map (μmap). Given that different tube voltages and currents are used in clinical PET/CT scanning protocols depending on patient size and the body region under study, this work was designed to evaluate the effect of tube settings and the presence of deep brain stimulation (DBS) metallic leads on the accuracy of CTAC. A commercial anthropomorphic head phantom and an in-house made polyethylene phantom were used in order to quantitatively measure the effect of the nominated parameters, using quantitative analysis of created μmaps, generated attenuation correction factors and reconstructed neurological PET emission data. A maximum absolute relative difference of 0.9% was observed between average CT numbers of images acquired at 300 mA and those acquired with tube currents from 20 to 280 mA in steps of 20 mA. Slopes equal to 5.79×10 -5, 5.34×10 -5 and 3.92×10 -5 for calibration curves corresponding to CT numbers greater than 0 HU were obtained at tube voltages of 140, 120 and 80 kVp, respectively. A relative difference of 36% and 27% for CT numbers of cortical bone measured at 80 kVp were observed in comparison with images acquired at 140 and 120 kVp, respectively. It was concluded that the attenuation map derivation is independent of tube current used for the settings explored in this work. Likewise, the visual qualitative interpretation and quantitative analysis of neurological PET emission images is independent of X-ray tube voltage. The DBS metallic leads do not create any visible or quantifiable artifacts in the reconstructed neurological PET images owing to their small size.

  6. Observed benefits from product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Haug, Anders; Mortensen, Niels Henrik

    2013-01-01

    This article presents a study of the benefits obtained from applying product configuration systems based on a case study in four industry companies. The impacts are described according to main objectives in literature for imple-menting product configuration systems: lead time in the specification...... affected by the use of product configu-ration systems e.g. increased sales, decrease in the number of SKU's, improved ability to introduce new products, and cost reductions.......This article presents a study of the benefits obtained from applying product configuration systems based on a case study in four industry companies. The impacts are described according to main objectives in literature for imple-menting product configuration systems: lead time in the specification...... systems in industry companies and partly to assess if the objectives suggested are appropriate for describing the impact of product configuration systems and identifying other possible objectives. The empirical study of the com-panies also gives an indication of more overall performance indicators being...

  7. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  8. Analysis of the Impact of Configuration of the Stabilisation System for Femoral Diaphyseal Fractures on the State of Stresses and Displacements

    Directory of Open Access Journals (Sweden)

    Jakub J. Słowiński

    2018-01-01

    Full Text Available Introduction. The treatment of femoral diaphyseal fractures by intramedullary nailing has become a common procedure in orthopaedic surgery. The purpose of this numerical simulation was to present how the changes in configuration of the stabilisation system can affect the stress and displacement state in the bone tissue and implanted device. Material and Methods. The numerical comparison of the stabilisation variants for the type 32-A2 femoral diaphyseal fracture (according to the AO classification performed by using the Charfix2 (ChM® anatomical nail locked in a number of chosen ways. The displacement and the stress distributions both in the bone and implant were obtained and analysed by computational simulation. Results. In all models, there was the same characteristic distribution, which shows there were minimal rotational movements of the bone around the anatomical axis. In all cases, stress concentrations were generated in the nail material in the area of the fracture gap. Conclusions. The obtained results indicate that there is a visible advantage to one-plane distal stabilisation in the reduction of stresses regardless of the type of proximal stabilisation. The results of calculations indicate that the use of proximal stabilisation with a neck screw reduces the possibility of damage to the implant.

  9. Investigations on high-pressure ribbed tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kling, G.

    1942-05-01

    During hydrogenation of coal, the reactants (coal paste and hydrogen) had to be heated to reaction temperature partly by heat exchange with products and partly by heating in hairpin tubes of a preheater. These hairpin tubes were heated externally by hot circulating gases. In order to improve heat transfer from the gases to the tubes, various types of metal ribbing were welded to the tubes to catch more heat and transfer it to the tubes. This report detailed some studies on the best shapes and dimensions and numbers of plates to be used. The report was limited to flat, rectangular-cross-section plates attached perpendicularly, instead of including flat circular plates, spiral plates, or other configurations. The advantage of greater surface area to catch more heat had to be balanced off against the disadvantage of greater surface area to absorb more heat in internal resistance to heat flow. The report described the experimental conditions, the modifications tested, and the shape decided upon as best for flat plates. Some of the diagrams illustrating temperature distributions around the tubes and ribs were presented in imitation three-dimenional formats. 16 figures.

  10. DNS BIND Server Configuration

    Directory of Open Access Journals (Sweden)

    Radu MARSANU

    2011-01-01

    Full Text Available After a brief presentation of the DNS and BIND standard for Unix platforms, the paper presents an application which has a principal objective, the configuring of the DNS BIND 9 server. The general objectives of the application are presented, follow by the description of the details of designing the program.

  11. DNS BIND Server Configuration

    OpenAIRE

    Radu MARSANU

    2011-01-01

    After a brief presentation of the DNS and BIND standard for Unix platforms, the paper presents an application which has a principal objective, the configuring of the DNS BIND 9 server. The general objectives of the application are presented, follow by the description of the details of designing the program.

  12. Configuration of bioreactors

    NARCIS (Netherlands)

    Martens, D.E.; End, van den E.J.; Streefland, M.

    2014-01-01

    Lab-scale stirred-tank bioreactors (0.2–20 l) are used for fundamental research on animal cells and in process development and troubleshooting for large-scale production. In this chapter, different configurations of bioreactor systems are shortly discussed and setting up these different

  13. Ansible configuration management

    CERN Document Server

    Hall, Daniel

    2015-01-01

    This book is intended for anyone who wants to learn Ansible starting from the basics. Some experience of how to set up and configure Linux machines and a working knowledge of BIND, MySQL, and other Linux daemons is expected.

  14. Placing a Hand in the Fire: Assessing the Impact of a YouTube Experiential Learning Project on Viral Marketing Knowledge Acquisition

    Science.gov (United States)

    Payne, Nathaniel J.; Campbell, Colin; Bal, Anjali S.; Piercy, Niall

    2011-01-01

    The goal of this study is to evaluate the effectiveness of an experiential learning social media project that was integrated into a graduate marketing class. As part of the semester-long project, students were required to work within a team and create a spoof video, which was posted on YouTube. Students' success was partially determined by the…

  15. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  16. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  17. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  18. Planning codes and the design of the street interface : Reading the impact of spatial configuration on street life using micro-scale tools

    NARCIS (Netherlands)

    De Carvalho Filho, L.M.; van Nes, A.

    2017-01-01

    This contribution is part of a PhD research. The study investigates the factors related to the vitality of street life in Brazilian cities. To what extent play urban form a part in forging the vitality of street life and why? What is the impact of the urban planning regime on the relation between

  19. Risk-based configuration control system: Analysis and approaches

    International Nuclear Information System (INIS)

    Samanta, P.K.; Vesely, W.E.; Kim, I.S.; Lofgren, E.V.

    1989-01-01

    This paper presents an analysis of risks associated with component outage configurations during power operation of a nuclear power plant and discusses approaches and strategies for developing a risk-based configuration control system. A configuration, as used here, is a set of component states. The objective of risk-based configuration control is to detect and control plant configurations using a risk-perspective. The configuration contributions to core-melt frequency and core-melt probability are studied for two plants. Large core-melt frequency can be caused by configurations and there are a number of such configurations that are not currently controlled by technical specifications. However, the expected frequency of occurrence of the impacting configurations is small and the actual core-melt probability contributions are also generally small. Effective strategies and criteria for controlling configuration risks are presented. Such control strategies take into consideration the risks associated with configurations, the nature and characteristics of the configuration risks, and also the practical considerations such as adequate repair times and/or options to transfer to low risk configurations. Alternative types of criteria are discussed that are not overly restrictive to result in unnecessary plant shutdown, but rather motivates effective tests and maintenance practices that control; risk-significant configurations to allow continued operation with an adequate margin to meet challenges to safety. 3 refs., 7 figs., 2 tabs

  20. Risk-based configuration control system: Analysis and approaches

    International Nuclear Information System (INIS)

    Samanta, P.K.; Kim, I.S.; Lofgren, E.V.; Vesely, W.E.

    1990-01-01

    This paper presents an analysis of risks associated with component outage configurations during power operation of a nuclear power plant and discusses approaches and strategies for developing a risk-based configuration control system. A configuration, as used here, is a set of component states. The objective of risk-based configuration control is to detect and control plant configurations using a risk-perspective. The configuration contributions to core-melt frequency and core-melt probability are studied for two plants. Large core-melt frequency can be caused by configurations and there are a number of such configurations that are not currently controlled by technical specifications. However, the expected frequency of occurrence of the impacting configurations is small and the actual core-melt probability contributions are also generally small. Effective strategies and criteria for controlling configuration risks are presented. Such control strategies take into consideration the risks associated with configurations, the nature and characteristics of the configuration risks, and also the practical considerations such as adequate repair times and/or options to transfer to low risk configurations. Alternative types of criteria are discussed that are not overly restrictive to result in unnecessary plant shutdown, but rather motivates effective test and maintenance practices that control risk-significant configurations to allow continued operation with an adequate margin to meet challenges to safety

  1. Sampling Artifacts from Conductive Silicone Tubing

    Energy Technology Data Exchange (ETDEWEB)

    Timko, Michael T.; Yu, Zhenhong; Kroll, Jesse; Jayne, John T.; Worsnop, Douglas R.; Miake-Lye, Richard C.; Onasch, Timothy B.; Liscinsky, David; Kirchstetter, Thomas W.; Destaillats, Hugo; Holder, Amara L.; Smith, Jared D.; Wilson, Kevin R.

    2009-05-15

    We report evidence that carbon impregnated conductive silicone tubing used in aerosol sampling systems can introduce two types of experimental artifacts: 1) silicon tubing dynamically absorbs carbon dioxide gas, requiring greater than 5 minutes to reach equilibrium and 2) silicone tubing emits organic contaminants containing siloxane that adsorb onto particles traveling through it and onto downstream quartz fiber filters. The consequence can be substantial for engine exhaust measurements as both artifacts directly impact calculations of particulate mass-based emission indices. The emission of contaminants from the silicone tubing can result in overestimation of organic particle mass concentrations based on real-time aerosol mass spectrometry and the off-line thermal analysis of quartz filters. The adsorption of siloxane contaminants can affect the surface properties of aerosol particles; we observed a marked reduction in the water-affinity of soot particles passed through conductive silicone tubing. These combined observations suggest that the silicone tubing artifacts may have wide consequence for the aerosol community and should, therefore, be used with caution. Gentle heating, physical and chemical properties of the particle carriers, exposure to solvents, and tubing age may influence siloxane uptake. The amount of contamination is expected to increase as the tubing surface area increases and as the particle surface area increases. The effect is observed at ambient temperature and enhanced by mild heating (<100 oC). Further evaluation is warranted.

  2. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    Science.gov (United States)

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all pcoagulation and blood gas (in syringe and capillary tube) laboratory tests.

  3. Improving the thermal efficiency of a jaggery production module using a fire-tube heat exchanger.

    Science.gov (United States)

    La Madrid, Raul; Orbegoso, Elder Mendoza; Saavedra, Rafael; Marcelo, Daniel

    2017-12-15

    Jaggery is a product obtained after heating and evaporation processes have been applied to sugar cane juice via the addition of thermal energy, followed by the crystallisation process through mechanical agitation. At present, jaggery production uses furnaces and pans that are designed empirically based on trial and error procedures, which results in low ranges of thermal efficiency operation. To rectify these deficiencies, this study proposes the use of fire-tube pans to increase heat transfer from the flue gases to the sugar cane juice. With the aim of increasing the thermal efficiency of a jaggery installation, a computational fluid dynamic (CFD)-based model was used as a numerical tool to design a fire-tube pan that would replace the existing finned flat pan. For this purpose, the original configuration of the jaggery furnace was simulated via a pre-validated CFD model in order to calculate its current thermal performance. Then, the newly-designed fire-tube pan was virtually replaced in the jaggery furnace with the aim of numerically estimating the thermal performance at the same operating conditions. A comparison of both simulations highlighted the growth of the heat transfer rate at around 105% in the heating/evaporation processes when the fire-tube pan replaced the original finned flat pan. This enhancement impacted the jaggery production installation, whereby the thermal efficiency of the installation increased from 31.4% to 42.8%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages

    Energy Technology Data Exchange (ETDEWEB)

    Euler, Andre; Stieltjes, Bram; Eichenberger, Reto; Reisinger, Clemens; Hirschmann, Anna; Zaehringer, Caroline; Kircher, Achim; Streif, Matthias; Bucher, Sabine; Buergler, David; D' Errico, Luigia; Kopp, Sebastien; Wilhelm, Markus [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Szucs-Farkas, Zsolt [Hospital Centre of Biel, Institute of Radiology, Biel (Switzerland); Schindera, Sebastian T. [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Cantonal Hospital Aarau, Institute of Radiology, Aarau (Switzerland)

    2017-12-15

    To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDI{sub vol}) was kept constant for all protocols. The datasets were reconstructed with MBIR and FBP. Image noise and contrast-to-noise-ratio (CNR) were assessed. Low-contrast lesion detectability was evaluated by 12 radiologists. MBIR decreased the image noise by 24% and 27%, and increased the CNR by 30% and 29% for the medium and large phantoms, respectively. Lower tube voltages increased the CNR by 58%, 46%, and 16% at 70, 80, and 100 kVp, respectively, compared with 120 kVp in the medium phantom and by 9%, 18% and 12% in the large phantom. No significant difference in lesion detection rate was observed (medium: 79-82%; large: 57-65%; P > 0.37). Although MBIR improved quantitative image quality compared with FBP, it did not result in increased low-contrast lesion detection in abdominal CT at different tube voltages in simulated medium and large patients. (orig.)

  5. Lunar Lava Tube Sensing

    Science.gov (United States)

    York, Cheryl Lynn; Walden, Bryce; Billings, Thomas L.; Reeder, P. Douglas

    1992-01-01

    Large (greater than 300 m diameter) lava tube caverns appear to exist on the Moon and could provide substantial safety and cost benefits for lunar bases. Over 40 m of basalt and regolith constitute the lava tube roof and would protect both construction and operations. Constant temperatures of -20 C reduce thermal stress on structures and machines. Base designs need not incorporate heavy shielding, so lightweight materials can be used and construction can be expedited. Identification and characterization of lava tube caverns can be incorporated into current precursor lunar mission plans. Some searches can even be done from Earth. Specific recommendations for lunar lava tube search and exploration are (1) an Earth-based radar interferometer, (2) an Earth-penetrating radar (EPR) orbiter, (3) kinetic penetrators for lunar lava tube confirmation, (4) a 'Moon Bat' hovering rocket vehicle, and (5) the use of other proposed landers and orbiters to help find lunar lava tubes.

  6. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  7. Microaerobic digestion of sewage sludge on an industrial-pilot scale: the efficiency of biogas desulphurisation under different configurations and the impact of O2 on the microbial communities.

    Science.gov (United States)

    Ramos, I; Pérez, R; Reinoso, M; Torio, R; Fdz-Polanco, M

    2014-07-01

    Biogas produced in an industrial-pilot scale sewage sludge reactor (5m(3)) was desulphurised by imposing microaerobic conditions. The H2S concentration removal efficiency was evaluated under various configurations: different mixing methods and O2 injection points. Biogas was entirely desulphurised under all the configurations set, while the O2 demand of the digester decreased over time. Although the H2S removal seemed to occur in the headspace, S(0) (which was found to be the main oxidation product) was scarcely deposited there in the headspace. O2 did not have a significant impact on the digestion performance; the VS removal remained around 47%. Conversely, DGGE revealed that the higher O2 transfer rate to the sludge maintained by biogas recirculation increased the microbial richness and evenness, and caused an important shift in the structure of the bacterial and the archaeal communities in the long term. All the archaeal genera identified (Methanosaeta, Methanospirillum and Methanoculleus) were present under both anaerobic and microaerobic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Investigations into the Impact of the Equivalence Ratio on Turbulent Premixed Combustion Using Particle Image Velocimetry and Large Eddy Simulation Techniques: “V” and “M” Flame Configurations in a Swirl Combustor

    KAUST Repository

    Kewlani, Gaurav

    2016-03-24

    Turbulent premixed combustion is studied using experiments and numerical simulations in an acoustically uncoupled cylindrical sudden-expansion swirl combustor, and the impact of the equivalence ratio on the flame–flow characteristics is analyzed. In order to numerically capture the inherent unsteadiness exhibited in the flow, the large eddy simulation (LES) technique based on the artificial flame thickening combustion model is employed. The experimental data are obtained using particle image velocimetry. It is observed that changes in heat loading, in the presence of wall confinement, significantly influence the flow field in the wake region, the stabilization location of the flame, and the flame intensity. Specifically, increasing the equivalence ratio drastically reduces the average inner recirculation zone size and causes transition of the flame macrostructure from the “V” configuration to the “M” configuration. In other words, while the flame stabilizes along the inner shear layer for the V flame, a persistent diffuse reaction zone is also manifested along the outer shear layer for the M flame. The average chemiluminescence intensity increases in the case of the M flame macrostructure, while the axial span of the reaction zone within the combustion chamber decreases. The predictions of the numerical approach resemble the experimental observations, suggesting that the LES framework can be an effective tool for examining the effect of heat loading on flame–flow interactions and the mechanism of transition of the flame macrostructure with a corresponding change in the equivalence ratio.

  9. Frecuencia de los defectos del tubo neural en Asturias: impacto del diagnóstico prenatal Prevalence of neural tube defects in Asturias (Spain: impact of prenatal diagnosis

    Directory of Open Access Journals (Sweden)

    Enrique García López

    2009-12-01

    Full Text Available Objetivo Describir la frecuencia de defectos del tubo neural (DTN -anencefalia, espina bífida y encefalocele-en Asturias, su evolución temporal y el impacto del diagnóstico prenatal. Métodos: Se estudiaron los casos de DTN en nacidos y abortos inducidos durante el período 1990-2004, utilizando la base de datos del Registro de Defectos Congénitos de Asturias, de base poblacional. Se calcularon las tasas de prevalencia total y al nacimiento. Resultados: La prevalencia total de DTN fue de 12,2 casos por 10.000 nacidos (5,9 anencefalias, 5,0 espinas bífidas y 1,3 encefaloceles y mostró una tendencia ligeramente descendente, con un descenso significativo de la espina bífida, mientras que las cifras de anencefalia y encefalocele se mantuvieron estables. Finalizaron en aborto inducido tras el diagnóstico prenatal el 88% de los casos (anencefalia 96,7%; espina bífida 80%; encefalocele 84,6%, lo que determinó una prevalencia al nacimiento muy baja (1,4 DTN por 10.000 nacidos. Conclusiones: En Asturias, en los últimos 15 años se ha producido un descenso selectivo en la prevalencia total de espina bífida de causa no aclarada. La prevención secundaria, mediante los programas de diagnóstico prenatal y la consiguiente interrupción del embarazo, fue el motivo del marcado descenso de la frecuencia en los nacidos; la simple recomendación de suplementación periconcepcional con ácido fólico no parece haber logrado el efecto buscado.Objective: To describe the frequency and prevalence trend for neural tube defects (NTD (anencephaly, spina bifida and encephalocele in Asturias (Spain, as well as the impact of prenatal diagnosis programs. Methods: All cases of NTD in births and induced abortions were studied, using data from the Registry of Congenital Defects of Asturias for 1990-2004. Total and birth prevalence rates were calculated. Results: The prevalence of NTD for 1990-2004 was 12.2 per 10,000 births (5.9 anencephaly, 5.0 spina bifida and 1

  10. Manual tube welding torch

    International Nuclear Information System (INIS)

    Kiefer, J.H.; Smith, D.J.

    1981-01-01

    In a welding torch which fits over a tube intermediate the ends thereof for welding the juncture between the tube and a boss on the back side of a tube plate, a split housing encloses a tungsten electrode, a filler wire duct and a fiber optic bundle arranged to observe the welding process. A shielding gas duct is provided in the housing. A screw is provided for setting electrode/work distance. Difficult remote tube welding operations can be performed with the apparatus. (author)

  11. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  12. Wound tube heat exchanger

    Science.gov (United States)

    Ecker, Amir L.

    1983-01-01

    What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

  13. Sapphire tube pressure vessel

    Science.gov (United States)

    Outwater, John O.

    2000-01-01

    A pressure vessel is provided for observing corrosive fluids at high temperatures and pressures. A transparent Teflon bag contains the corrosive fluid and provides an inert barrier. The Teflon bag is placed within a sapphire tube, which forms a pressure boundary. The tube is received within a pipe including a viewing window. The combination of the Teflon bag, sapphire tube and pipe provides a strong and inert pressure vessel. In an alternative embodiment, tie rods connect together compression fittings at opposite ends of the sapphire tube.

  14. Fuel nozzle tube retention

    Energy Technology Data Exchange (ETDEWEB)

    Cihlar, David William; Melton, Patrick Benedict

    2017-02-28

    A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

  15. Vertical and horizontal access configurations

    International Nuclear Information System (INIS)

    Spampinato, P.T.

    1987-01-01

    A number of configuration features and maintenance operations are influenced by the choice of whether a design is based on vertical or horizontal access for replacing reactor components. The features which are impacted most include the first wall/blanket segmentation, the poloidal field coil locations, the toroidal field coil number and size, access port size for in-vessel components, and facilities. Since either configuration can be made to work, the choice between the two is not clear cut because both have certain advantages. It is apparent that there are large cost benefits in the poloidal field coil system for ideal coil locations for high elongation plasmas and marginal savings for the INTOR case. If we assume that a new tokamak design will require a higher plasma elongation, the recommendation is to arrange the poloidal field coils in a cost-effective manner while providing reasonable midplane access for heating interfaces and test modules. If a new design study is not based on a high elongation plasma, it still appears prudent to consider this approach so that in-vessel maintenance can be accomplished without moving very massive structures such as the bulk shield. 10 refs., 29 figs., 3 tabs

  16. Structural Configuration of Myelin Figures Using Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Lobat Tayebi

    2012-01-01

    Full Text Available Using epifluorescence microscopy, the configuration of myelin figures that are formed upon hydration of lipid stack was studied qualitatively. Little knowledge is currently available for conditions that determine the diameter of myelin figures and their degree of multilamellarity. Examining more than 300 samples, we realized that there are distinct populations of myelin figures protruding from discrete regions of lipid stack. Each population contains myelin figures with similar diameters. This indicates a direct relationship between local characteristics of parent lipid stack and the diameter of myelin figures. Evidenced by fluorescent images, we classified all the observed myelin figures into three major groups of (1 solid tubes, (2 thin tethers, and (3 hollow tubes. Solid tubes are the most common structure of myelin figures which appeared as dense shiny cylinders. Thin tethers, with long hair-shaped structure, were observed protruding from part of lipid plaque which is likely to be under tension. Hollow tubes were protruded from the parts that are unpinned from the substrate and possibly under low or no tension. The abrupt change in the configuration of myelin figures from solid tubes to hollow ones was described in a reproducible experiment where the pinned region of the parent stack became unpinned. Our observations can indicate a relation between the membrane tension of the source material and the diameter of the myelin figures.

  17. Resolution of lava tubes with ground penetrating radar: preliminary results from the TubeX project

    Science.gov (United States)

    Esmaeili, S.; Kruse, S.; Garry, W. B.; Whelley, P.; Young, K.; Jazayeri, S.; Bell, E.; Paylor, R.

    2017-12-01

    As early as the mid 1970's it was postulated that planetary tubes or caves on other planetary bodies (i.e., the Moon or Mars) could provide safe havens for human crews, protect life and shield equipment from harmful radiation, rapidly fluctuating surface temperatures, and even meteorite impacts. What is not clear, however, are the exploration methods necessary to evaluate a potential tube-rich environment to locate suitable tubes suitable for human habitation. We seek to address this knowledge gap using a suite of instruments to detect and document tubes in a terrestrial analog study at Lava Beds National Monument, California, USA. Here we describe the results of ground penetrating radar (GPR) profiles and light detection and ranging (LiDAR) scans. Surveys were conducted from the surface and within four lava tubes (Hercules Leg, Skull, Valentine and, Indian Well Caves) with varying flow composition, shape, and complexity. Results are shown across segments of these tubes where the tubes are 10 m in height and the ceilings are 1 - 10 m below the surface. The GPR profiles over the tubes are, as expected, complex, due to scattering from fractures in roof material and three-dimensional heterogeneities. Point clouds derived from the LiDAR scans of both the interior and exterior of the lava tubes provide precise positioning of the tube geometry and depth of the ceiling and floor with respect to the surface topography. GPR profiles over LiDAR-mapped tube cross-sections are presented and compared against synthetic models of radar response to the measured geometry. This comparison will help to better understand the origins of characteristic features in the radar profiles. We seek to identify the optimal data processing and migration approaches to aid lava tube exploration of planetary surfaces.

  18. An advanced tube wear and fatigue workstation to predict flow induced vibrations of steam generator tubes

    International Nuclear Information System (INIS)

    Gay, N.; Baratte, C.; Flesch, B.

    1997-01-01

    Flow induced tube vibration damage is a major concern for designers and operators of nuclear power plant steam generators (SG). The operating flow-induced vibrational behaviour has to be estimated accurately to allow a precise evaluation of the new safety margins in order to optimize the maintenance policy. For this purpose, an industrial 'Tube Wear and Fatigue Workstation', called 'GEVIBUS Workstation' and based on an advanced methodology for predictive analysis of flow-induced vibration of tube bundles subject to cross-flow has been developed at Electricite de France. The GEVIBUS Workstation is an interactive processor linking modules as: thermalhydraulic computation, parametric finite element builder, interface between finite element model, thermalhydraulic code and vibratory response computations, refining modelling of fluid-elastic and random forces, linear and non-linear dynamic response and the coupled fluid-structure system, evaluation of tube damage due to fatigue and wear, graphical outputs. Two practical applications are also presented in the paper; the first simulation refers to an experimental set-up consisting of a straight tube bundle subject to water cross-flow, while the second one deals with an industrial configuration which has been observed in some operating steam generators i.e., top tube support plate degradation. In the first case the GEVIBUS predictions in terms of tube displacement time histories and phase planes have been found in very good agreement with experiment. In the second application the GEVIBUS computation showed that a tube with localized degradation is much more stable than a tube located in an extended degradation zone. Important conclusions are also drawn concerning maintenance. (author)

  19. Configuration Management Program Plan

    International Nuclear Information System (INIS)

    1991-01-01

    Westinghouse Savannah River Company (WSRC) has established a configuration management (CM) plan to execute the SRS CM Policy and the requirements of the DOE Order 4700.1. The Reactor Restart Division (RRD) has developed its CM Plan under the SRS CM Program and is implementing it via the RRD CM Program Plan and the Integrated Action Plan. The purpose of the RRD CM program is to improve those processes which are essential to the safe and efficient operation of SRS production reactors. This document provides details of this plan

  20. NASA's acquisition requirements for configuration management

    Science.gov (United States)

    Coletta, Mark P.

    1992-01-01

    A viewgraph presentation on NASA's acquisition requirements for configuration management (CM) goes over CM requirements for single mission and multi-mission orientations, CM automation and CALS implementation initiatives, NASA implementation of DOD standards and DID's (data item descriptions), impact of traceability in NASA CM support, NASA's CM efforts in modifying/upgrading equipment, and CM control of multi-vendor hardware.

  1. Toward risk-based control of nuclear power plant configurations

    International Nuclear Information System (INIS)

    Samanta, P.K.; Veseley, W.E.; Kim, I.S.

    1992-01-01

    This paper presents an evaluation of the configuration risks associated with the operation of a nuclear power plant and the approaches to control these risks using risk-based configuration control considerations. In that context, the actual and maximum potential configuration risks at a plant are analyzed and the alternative types criteria for a risk-based configuration control systems are described. The risk-based configuration calculations which are studied here focus on the core-melt frequency impacts from given plant configurations, the configurations which cause large core-melt frequency increases can be identified and controlled. The duration time in which the configuration can exist can then be limited or the core-melt frequency level associated with the configuration can be reduced by various actions. Futhermore, maintenances and tests can be scheduled to avoid the configurations which cause large core-melt frequency increases. Present technical specifications do not control many of these configurations which can cause large core-melt frequency increases but instead focus on many risk-unimportant allowed outage times. Hence, risk-based configuration management can be effectively used to reduce core-melt frequency associated risks at a plant and at the same time can provide flexibility in plant operation. The alternative strategies for controlling the core-melt frequency and other risk contributions include: (1) controlling the increased risk level which is associated with the configuration; (2) controlling the individual configuration risk which is associated with a given duration of a configuration; (3) controlling the time period configuration risk from configurations which occur in a time period. (orig.)

  2. Chest Tube Thoracostomy

    Science.gov (United States)

    ... in the space around the lungs (called a pleural effusion) . A chest tube may also be needed when a patient has ... or chest CT are also done to evaluate pleural fluid. If the X-ray shows a need for a chest tube to drain fluid or air, the procedure is ...

  3. Ventricular tachycardia following tube thoracotomy.

    Science.gov (United States)

    Hibbert, Benjamin; Lim, Toon Wei; Hibbert, Rebecca; Green, Martin; Gollob, Michael H; Davis, Darryl R

    2010-10-01

    Arrhythmias provoked by tube thoracotomy are a rare complication. We report a ventricular tachycardia after chest tube insertion for a device-related pneumothorax. Sinus rhythm was restored only by removal of the chest tube and insertion of a pliable pleural drain. Identification of the chest tube as an arrhythmic trigger following tube thoracotomy is essential in definitive management of refractory arrhythmias.

  4. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  5. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s...... technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  6. Performance of tubes-and plate fins heat exchangers

    International Nuclear Information System (INIS)

    Rosman, E.C.

    1979-11-01

    By means of a two-dimensional analysis performance, and using local heat transfer coefficients, the plate fin temperature distribution, the air bulk temperature along the stream path and the fin efficiency can be obtained, for several Reynolds numbers and fin materials. Herein are also presented the average heat transfer coefficients for isothermal plate fins, referring to heat exchangers with central-tube and rear-tube row and to two-row tubes heat exchangers configurations. It is possible to obtain the real tax or the real area of heat transfer, using the average hea transfer coefficients for isothermal plate fins and the fin efficiency. (Author) [pt

  7. Ames Optimized TCA Configuration

    Science.gov (United States)

    Cliff, Susan E.; Reuther, James J.; Hicks, Raymond M.

    1999-01-01

    Configuration design at Ames was carried out with the SYN87-SB (single block) Euler code using a 193 x 49 x 65 C-H grid. The Euler solver is coupled to the constrained (NPSOL) and the unconstrained (QNMDIF) optimization packages. Since the single block grid is able to model only wing-body configurations, the nacelle/diverter effects were included in the optimization process by SYN87's option to superimpose the nacelle/diverter interference pressures on the wing. These interference pressures were calculated using the AIRPLANE code. AIRPLANE is an Euler solver that uses a unstructured tetrahedral mesh and is capable of computations about arbitrary complete configurations. In addition, the buoyancy effects of the nacelle/diverters were also included in the design process by imposing the pressure field obtained during the design process onto the triangulated surfaces of the nacelle/diverter mesh generated by AIRPLANE. The interference pressures and nacelle buoyancy effects are added to the final forces after each flow field calculation. Full details of the (recently enhanced) ghost nacelle capability are given in a related talk. The pseudo nacelle corrections were greatly improved during this design cycle. During the Ref H and Cycle 1 design activities, the nacelles were only translated and pitched. In the cycle 2 design effort the nacelles can translate vertically, and pitch to accommodate the changes in the lower surface geometry. The diverter heights (between their leading and trailing edges) were modified during design as the shape of the lower wing changed, with the drag of the diverter changing accordingly. Both adjoint and finite difference gradients were used during optimization. The adjoint-based gradients were found to give good direction in the design space for configurations near the starting point, but as the design approached a minimum, the finite difference gradients were found to be more accurate. Use of finite difference gradients was limited by the

  8. Survey of prenatal screening policies in Europe for structural malformations and chromosome anomalies, and their impact on detection and termination rates for neural tube defects and Down's syndrome

    DEFF Research Database (Denmark)

    Boyd, P A; Devigan, C; Khoshnood, B

    2008-01-01

    tube defects (NTDs) using the EUROCAT database. MAIN OUTCOME MEASURES: Existence of national prenatal screening policies, legal gestation limit for TOPFA, prenatal detection and termination rates for Down's syndrome and NTD. RESULTS: Ten of the 18 countries had a national country-wide policy for Down...... cases. Six of the 18 countries had a legal gestational age limit for TOPFA, and in two countries, termination of pregnancy was illegal at any gestation. CONCLUSIONS: There are large differences in screening policies between countries in Europe. These, as well as organisational and cultural factors...

  9. On (v,k)-configurations

    International Nuclear Information System (INIS)

    Malyshev, F M; Tarakanov, V E

    2001-01-01

    New combinatorial objects, which we call (v,k)-configurations, are introduced and studied. They occur as a result of weakening the conditions defining well-known combinatorial objects, the (v,k,λ)-configurations. Existence results for (v,k)-configurations are proved and methods for constructing them are indicated, based, in particular, upon group-theoretic constructions and quadratic residues modulo a prime. An extended list of examples of (v,k)-configurations, including several infinite series, is presented

  10. Configuring the autism epidemic

    DEFF Research Database (Denmark)

    Seeberg, Jens; Christensen, Fie Lund Lindegaard

    2017-01-01

    is skewed in favour of boys, and girls with autism tend to be diagnosed much later than boys. Building and further developing the notion of ‘configuration’ of epidemics, this article explores the configuration of autism in Denmark, with a particular focus on the health system and social support to families...... with children diagnosed with autism, seen from a parental perspective. The article points to diagnostic dynamics that contribute to explaining why girls with autism are not diagnosed as easily as boys. We unfold these dynamics through the analysis of a case of a Danish family with autism.......Autism has been described as an epidemic, but this claim is contested and may point to an awareness epidemic, i.e. changes in the definition of what autism is and more attention being invested in diagnosis leading to a rise in registered cases. The sex ratio of children diagnosed with autism...

  11. Software Configurable Multichannel Transceiver

    Science.gov (United States)

    Freudinger, Lawrence C.; Cornelius, Harold; Hickling, Ron; Brooks, Walter

    2009-01-01

    Emerging test instrumentation and test scenarios increasingly require network communication to manage complexity. Adapting wireless communication infrastructure to accommodate challenging testing needs can benefit from reconfigurable radio technology. A fundamental requirement for a software-definable radio system is independence from carrier frequencies, one of the radio components that to date has seen only limited progress toward programmability. This paper overviews an ongoing project to validate the viability of a promising chipset that performs conversion of radio frequency (RF) signals directly into digital data for the wireless receiver and, for the transmitter, converts digital data into RF signals. The Software Configurable Multichannel Transceiver (SCMT) enables four transmitters and four receivers in a single unit the size of a commodity disk drive, programmable for any frequency band between 1 MHz and 6 GHz.

  12. Representation of spatial and temporal variability of daily wind speed and of intense wind events over the Mediterranean Sea using dynamical downscaling: impact of the regional climate model configuration

    Directory of Open Access Journals (Sweden)

    M. Herrmann

    2011-07-01

    variability, in particular in regions strongly influenced by the complex surrounding orography. The impact of the interactive air-sea coupling is negligible for the temporal scales examined here. Using two different forcing datasets induces differences on the downscaled fields that are directly related to the differences between those datasets. Our results also show that improving the physics of our RCM is still necessary to increase the realism of our simulations. Finally, the choice of the optimal configuration depends on the scientific objectives of the study for which those wind datasets are used.

  13. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  14. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  15. Impact and appreciation of two methods aiming at reducing hazardous drug environmental contamination: The centralization of the priming of IV tubing in the pharmacy and use of a closed-system transfer device.

    Science.gov (United States)

    Guillemette, Annie; Langlois, Hélène; Voisine, Maxime; Merger, Delphine; Therrien, Roxane; Mercier, Genevieve; Lebel, Denis; Bussières, Jean-François

    2014-12-01

    The main objective was to evaluate the impact of two methods aiming at reducing hazardous drug environmental contamination: the centralization of the priming of IV tubing in the pharmacy and the use of a closed-system transfer device. The secondary objective was to evaluate the satisfaction of pharmacy technicians using a survey. Sites in the hematology-oncology satellite pharmacy and care unit were analyzed for the presence of cyclophosphamide, ifosfamide and methotrexate before and after the centralization of the priming of IV tubing in the pharmacy and before and after using a closed-system transfer device. The limits of detection for cyclophosphamide, ifosfamide and methotrexate were, respectively, of 0.0015 ng/cm(2), 0.0012 ng/cm(2) and 0.0060 ng/cm(2). The pharmacy technician satisfaction was evaluated using a questionnaire. A total of 225 samples was quantified. After the centralization of priming in the pharmacy, no significant difference was found in the proportion of positive samples for cyclophosphamide, ifosfamide and methotrexate. Traces of cyclophosphamide found on the floor in patient care areas was significantly reduced (median[min-max] 0.08[0.06-0.09]ng/cm(2) vs. 0.03[0.02-0.05], p handling difficulties). The centralization of the priming of IV tubing in the pharmacy reduced floor contamination in patient care areas without increasing surface contamination in the pharmacy. Closed-system transfer devices reduced contamination in pharmacy, but handling issues were raised by pharmacy technicians. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Application of Configurators in Networks

    DEFF Research Database (Denmark)

    Malis, Martin; Hvam, Lars

    2003-01-01

    Shorter lead-time, improved quality of product specifications and better communication with customers and suppliers are benefits derived from the application of configurators. Configurators are knowledge-based IT-systems that can be applied to deal with product knowledge and to support different...... processes in a company. Traditionally, configurators have been used as an internal tool. In this paper focus will be on the application of configurators in a network of companies, and a procedure for developing product configurators in a network of companies will be presented. The aim is to present...... a structured guideline, tools and methods on how to successfully develop configurators in a network perspective. Findings presented in this paper are supported by research in a case company. The results from the empirical work show a huge potential for the application of configurators in networks of companies....

  17. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  18. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  19. Tube Alinement for Machining

    Science.gov (United States)

    Garcia, J.

    1984-01-01

    Tool with stepped shoulders alines tubes for machining in preparation for welding. Alinement with machine tool axis accurate to within 5 mils (0.13mm) and completed much faster than visual setup by machinist.

  20. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1982-04-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1980. Tube defects occurred at 38% of the 97 reactors surveyed. This is a marginal improvement over 1979 when defects occurred at 41% of the reactors. The number of failed tubes was also lower, 0.14% of the tubes in service in 1980 compared with 0.20% of those in service in 1979. Analysis of the causes of these failures indicates that stress corrosion cracking was the leading failure mechanism. Reactors that used all-volatile treatment of secondary water, with or without full-flow condensate demineralization since start-up showed the lowest incidence of corrosion-related defects

  1. Ear tube insertion

    Science.gov (United States)

    ... mastoiditis) or the brain, or that damages nearby nerves Injury to the ear after sudden changes in ... does not heal after the tube falls out. Most of the time, these problems DO NOT last long. They also ...

  2. Tube Feeding Troubleshooting Guide

    Science.gov (United States)

    ... the diameter is measured in units known as French sizes, or “Fr”; a low profile tube also ... your quality of life. You are encouraged to speak with your physician, dietitian, home care company, or ...

  3. Dual-Source Dual-Energy CT Angiography of the Supra-Aortic Arteries with Tin Filter: Impact of Tube Voltage Selection.

    Science.gov (United States)

    Korn, Andreas; Bender, Benjamin; Schabel, Christoph; Bongers, Malte; Ernemann, Ulrike; Claussen, Claus; Thomas, Christoph

    2015-06-01

    Automatic bone and plaque subtraction (BPS) in computed tomographic angiographic (CTA) examinations using dual-energy CT (DECT) remains challenging because of beam-hardening artifacts in the shoulder region and close proximity of the internal carotid artery to the base of the skull. The selection of the tube voltage combination in dual-source CT influences the spectral separation and the susceptibility for artifacts. The purpose of this study was to assess which tube voltage combination leads to an optimal image quality of head and neck DECT angiograms after bone subtraction. Fifty-one patients received tin-filter-enhanced DECT angiograms of the supra-aortic arteries using two voltage protocols: 24 patients were studied using 80/Sn140 kV and 27 using a 100/Sn140 kV protocol, both protocols with an additional tin filter. A commercially available DE-CTA BPS algorithm was used. Artificial vessel erosions in BPS maximum intensity projections (four-level Likert scale with CTA source data as reference) and vessel signal-to-noise ratio (SNR) were assessed in the level of the shoulders and the base of the skull in each patient and compared. At the level of the shoulder, 100/Sn140 kV achieved higher SNR (23.4 ± 6.4 at 80/Sn140 kV vs. 35.1 ± 11.8 at 100/Sn140 kV; P supra-aortic arteries than the 80/Sn140 kV protocol. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  4. Magnesium tube hydroforming

    Energy Technology Data Exchange (ETDEWEB)

    Liewald, M.; Pop, R. [Institute for Metal Forming Technology (IFU), Stuttgart (Germany)

    2008-04-15

    Magnesium alloys reveal a good strength-to-weight ratio in the family of lightweight metals and gains potential to provide up to 30% mass savings compared to aluminium and up to 75 % compared to steel. The use of sheet magnesium alloys for auto body applications is however limited due to the relatively low formability at room temperature. Within the scope of this paper, extruded magnesium tubes, which are suitable for hydroforming applications, have been investigated. Results obtained at room temperature using magnesium AZ31 tubes show that circumferential strains are limited to a maximal value of 4%. In order to examine the influence of the forming temperature on tube formability, investigations have been carried out with a new die set for hot internal high pressure (IHP) forming at temperatures up to 400 C. Earlier investigations with magnesium AZ31 tubes have shown that fractures occur along the welding line at tubes extruded over a spider die, whereby a non-uniform expansion at bursting with an elongation value of 24% can be observed. A maximum circumferential strain of approx. 60% could be attained when seamless, mechanically pre-expanded and annealed tubes of the same alloy have been used. The effect of annealing time on materials forming properties shows a fine grained structure for sufficient annealing times as well as deterioration with a large increase at same time. Hence, seamless ZM21 tubes have been used in the current investigations. With these tubes, an increased tensile fracture strain of 116% at 350 C is observed as against 19% at 20 C, obtained by tensile testing of milled specimens from the extruded tubes. This behaviour is also seen under the condition of tool contact during the IHP forming process. To determine the maximum circumferential strain at different forming temperatures and strain rates, the tubes are initially bulged in a die with square cross-section under plane stress conditions. Thereafter, the tubes are calibrated by using an

  5. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  6. Total equipment parts configuration

    International Nuclear Information System (INIS)

    Ferrare, J.

    1989-01-01

    Florida Power ampersand Lights's (FP ampersand L's) Turkey Point units were built prior to the establishment of American Society of Mechanical Engineers' Sec. III requirements. Since that time, FP ampersand L has voluntarily committed to procuring some spare and replacement parts in compliance with the ordering requirements of ASME Sec. III. New subsystems were designed according to ASME Sec. III requirements. In 1978, 10CFR21 of the Code of Federal Regulations was federally mandated. Environmental qualification concerns and the Three Mile Island incident further complicated the stocking and ordering of spare and replacement parts. Turkey Point assembled a team of quality assurance, quality control, and engineering people and obtained permission to directly access the store department computer so that catalog descriptions could be quickly made available for use by the plant. The total equipment parts configuration (TEPC) system was designed and developed under the direction of the procurement document review team at the Turkey Point nuclear plant. The system is a network of related computer data bases that identifies the equipment at the plant. The equipment (or components that make up a piece of equipment) is identified by a tag/component code system. Each component is further broken down by the manufacturer's parts list or bill of material. A description of the data available to the user, the ways these data can be accessed and displayed, and a description of the data bases and their relation to each other are summarized in this paper

  7. Configuration space Faddeev calculations

    International Nuclear Information System (INIS)

    Payne, G.L.; Klink, W.H.; Ployzou, W.N.

    1991-01-01

    The detailed study of few-body systems provides one of the most precise tools for studying the dynamics of nuclei. Our research program consists of a careful theoretical study of the nuclear few-body systems. During the past year we have completed several aspects of this program. We have continued our program of using the trinucleon system to investigate the validity of various realistic nucleon-nucleon potentials. Also, the effects of meson-exchange currents in nuclear systems have been studied. Initial calculations using the configuration-space Faddeev equations for nucleon-deuteron scattering have been completed. With modifications to treat relativistic systems, few-body methods can be applied to phenomena that are sensitive to the structure of the individual hadrons. We have completed a review of Relativistic Hamiltonian Dynamics in Nuclear and Particle Physics for Advances in Nuclear Physics. Although it is called a review, it is a large document that contains a significant amount of new research

  8. Instrumented tube burns: theoretical and experimental observations

    Energy Technology Data Exchange (ETDEWEB)

    Yarrington, Cole Davis [Los Alamos National Laboratory; Obrey, Stephen J [Los Alamos National Laboratory; Foley, Timothy J [Los Alamos National Laboratory; Son, Steven F [Los Alamos National Laboratory

    2009-01-01

    The advent of widely available nanoscale energetic composites has resulted in a flurry of novel applications. One of these applications is the use of nanomaterials in energetic compositions. In compositions that exhibit high sensitivity to stimulus, these materials are often termed metastable intermolecular composites (MIC). More generally, these compositions are simply called nanoenergetics. Researchers have used many different experimental techniques to analyze the various properties of nanoenergetic systems. Among these various techniques, the confined tube burn is a simple experiment that is capable of obtaining much data related to the combustion of these materials. The purpose of this report is to review the current state of the confined tube burn experiment, including the drawbacks of the technique and possible remedies. As this report is intended to focus on the specific experimental technique, data from many different energetic materials, and experimental configurations will be presented. The qualitative and quantitative data that can be gathered using confined tube burn experiments include burning rates, total impulse, pressure rise rate, and burning rate differences between different detector types. All of these measurements lend insight into the combustion properties and mechanisms of specific nanoenergetics. Finally, certain data indicates a more complicated flow scenario which may need to be considered when developing burn tube models.

  9. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  10. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    ... tube feeding; PEG tube care; Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding ... pump (includes a feeding bag, drip chamber, roller clamp, ...

  11. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  12. Development and test evaluation of duplex steam reformer tube

    International Nuclear Information System (INIS)

    Allen, D.C.; Meyer, D.J.; Pflasterer, G.R.

    1980-01-01

    For HTR applications involving a steam reformer (SR), it is uncertain whether an intermediate heat exchanger (IHX) is required. There are several system configurations that could be developed for the application of nuclear heat using the steam reformer reaction. The considerations (advantages vs. disadvantages) for each of the system configurations are summarized. The approach that technically and economically appears to be the most attractive, in studies conducted by General Electric, combines the SR process heat exchanger and the IHX in a single component using a duplex tube. A central question concerning the duplex tube concept is whether the design would provide adequate leak monitoring capability and significant reduction in tritium and hydrogen diffusion, while introducing only a small increase in overall temperature difference from the helium to the process gas. A cooperative GE-KFA effort was undertaken to develop, fabricate, test, and evaluate a duplex steam reformer tube. GE was responsible for the development and fabrication of the tube, and KFA was responsible for testing the tube in the EVA I facility at Juelich. Both GE and KFA are evaluating the thermochemical and metallurgical test data. Actual fabrication of the tube was performed by Foster-Wheeler in accordance with the GE design. This paper reviews the highlights of the fabrication development and preliminary evaluation of the test data

  13. Experiments on vibration of heat exchanger tube arrays in cross flow

    International Nuclear Information System (INIS)

    Blevins, R.D.; Gibert, R.J.; Villard, B.

    1981-08-01

    A series of tests have been made at the Commissariat a l'Energie Atomique, in cooperation with General Atomic Company, SAN DIEGO (U.S.A.) on the flow-induced vibration of heat exchanger tube bundles in cross flow. These tests were made in air on tube bundles which simulated heat exchangers in the high temperature gas cooled reactors. The tests were of two types. In the first type, an instrumented tube was inserted at various locations into a tube bundle. Measurements were made of pressure at a number of points along the tube and about the circumference of the tube. These measurements were processed to obtain the spectra of turbulent pressure fluctuations on the tube, the spanwise correlation and the lift force. The second set of tests was made on tube bundles with flexible tubes. As the flow velocity was increased, these tests clearly show an instability. Nine tube configurations were tested with both plastic and metallic tubes and the effect of tube-to-tube difference in natural frequency was investigated

  14. Measurements of absorbed heat flux and water-side heat transfer coefficient in water wall tubes

    Science.gov (United States)

    Taler, Jan; Taler, Dawid; Kowal, Andrzej

    2011-04-01

    The tubular type instrument (flux tube) was developed to identify boundary conditions in water wall tubes of steam boilers. The meter is constructed from a short length of eccentric tube containing four thermocouples on the fire side below the inner and outer surfaces of the tube. The fifth thermocouple is located at the rear of the tube on the casing side of the water-wall tube. The boundary conditions on the outer and inner surfaces of the water flux-tube are determined based on temperature measurements at the interior locations. Four K-type sheathed thermocouples of 1 mm in diameter, are inserted into holes, which are parallel to the tube axis. The non-linear least squares problem is solved numerically using the Levenberg-Marquardt method. The heat transfer conditions in adjacent boiler tubes have no impact on the temperature distribution in the flux tubes.

  15. Aquifer Sampling Tube Results for Fiscal Year 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, Mary J.; Peterson, Robert E.

    2003-10-27

    This report presents and discusses results of the fiscal year 2003 sampling event associated with aquifer tubes along the Columbia River in the northern Hanford Site. Aquifer tube data help define the extent of groundwater contamination near the river, determine vertical variations in contamination, monitor the performance of interim remedial actions near the river, and support impact studies.

  16. Corrosion performance of tube support materials

    International Nuclear Information System (INIS)

    Malagola, P.

    1985-01-01

    The problem of denting in steam generators leads to change in the conception of the tube support plates. A new material is now used for this component, a 13% Cr steel, which composition has been adjusted for weldability and mechanical resistance criteria. The geometry of trefoil support plate (TSP) has also been improved, using a broached TSP (quadrifoiled holes) instead of a drilled TSP. Tests have been performed on 13% Cr and C-steel broached TSP, and drilled TSP, to confirm the better resistance to denting of this new configuration

  17. Six-Inch Shock Tube Characterization

    Science.gov (United States)

    2016-12-09

    with compressed air separated from the rest of the tube by a frangible diaphragm and rupturing that diaphragm. On command, a mechanical knife ruptures...ruptured. The cylinder pressure decreased by 5 psi for subsequent sets of shots until the membrane no longer ruptured. The characterization fired five... shots for each of the Mylar® and pressure configurations: 92A at 5 to 10 psi; 200A at 5 to 22 psi; 200S at 5 to 15 psi; 500A at 40 to 80 psi; 1000A at

  18. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  19. Tachyon tube on non BPS D-branes

    International Nuclear Information System (INIS)

    Huang Wunghong

    2004-01-01

    We report our searches for a single tubular tachyonic solution of regular profile on unstable non BPS D3-branes. We first show that some extended Dirac-Born-Infeld tachyon actions in which new contributions are added to avoid the Derrick's no-go theorem still could not have a single regular tube solution. Next we use the Minahan-Zwiebach tachyon action to find the regular tube solutions with circular or elliptic cross section. With a critical electric field, the energy of the tube comes entirely from the D0 and strings, while the energy associated to the tubular D2-brane tension is vanishing. We also show that fluctuation spectrum around the tube solution does not contain tachyonic mode. The results are consistent with the identification of the tubular configuration as a BPS D2-brane. (author)

  20. Circumferential buckling instability of a growing cylindrical tube

    KAUST Repository

    Moulton, D.E.

    2011-03-01

    A cylindrical elastic tube under uniform radial external pressure will buckle circumferentially to a non-circular cross-section at a critical pressure. The buckling represents an instability of the inner or outer edge of the tube. This is a common phenomenon in biological tissues, where it is referred to as mucosal folding. Here, we investigate this buckling instability in a growing elastic tube. A change in thickness due to growth can have a dramatic impact on circumferential buckling, both in the critical pressure and the buckling pattern. We consider both single- and bi-layer tubes and multiple boundary conditions. We highlight the competition between geometric effects, i.e. the change in tube dimensions, and mechanical effects, i.e. the effect of residual stress, due to differential growth. This competition can lead to non-intuitive results, such as a tube growing to be thinner and yet buckle at a higher pressure. © 2011 Elsevier Ltd. All rights reserved.

  1. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert

    2013-10-01

    Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.

  2. Reference frame for Product Configuration

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Oddsson, Gudmundur Valur

    2011-01-01

    This paper presents a reference frame for configuration. The reference frame is established by review of existing literature, and consequently it is a theoretical frame of reference. The review of literature shows a deterioration of the understanding of configuration. Most recent literature reports...

  3. Moderator Configuration Options for ESS

    DEFF Research Database (Denmark)

    Zanini, L.; Batkov, K.; Klinkby, Esben Bryndt

    2016-01-01

    conventional, principles were also considered,such as the importance of moderator positioning, of the premoderator, and beam extraction considerations. Different design and configuration options are evaluated and compared with the reference volume moderator configuration described in the ESS Technical Design...

  4. Fill tube fitted spheres

    International Nuclear Information System (INIS)

    Ives, B.H.

    1981-01-01

    The high temperature diffusion technique for fuel filling of some future direct drive cryogenic ICF targets may be unacceptable. The following describes a technique of fitting a 1 mm diameter x 6 μm thick glass microsphere with an approx. 50 μm O.D. glass fill tube. The process of laser drilling a 50 μm diameter hole in the microsphere wall, technique for making the epoxy joint between the sphere and fill tube, as well as the assembly procedure are also discussed

  5. Beware of the malformed nasogastric tube

    Science.gov (United States)

    Garg, Rakesh; Khanna, Puneet; S, Siva Kumaran; Sonny, Abraham

    2009-01-01

    Untoward events with faulty instruments and apparatus are well known and if not recognised can be disastrous. We present a case of a faulty nasogastric tube having both ends sharp-edged and closed with a detachable blocker. In our case, had we inserted the faulty nasogastric tube, the impact of the blocker, although small, in the tract could have eroded the nasal/oesophageal/gastric mucosa causing its sequalae. Thus, we would like to emphasise the need to check all instruments before using them to prevent any catastrophic complication. PMID:21686494

  6. Steam generator tube vibration study

    International Nuclear Information System (INIS)

    Enderlin, W.I.

    1986-01-01

    Chemical cleaning has been proposed to remove magnetite buildup in some pressurized water reactor steam generators. The US Nuclear Regulatory Commission (NRC) has expressed concern that such cleaning would combine with the tube denting caused by magnetite formation to enlarge tube/tube support plate clearances, increasing the level of flow-induced vibrations that could lead to unacceptably high tube wear and failure rates. In support of NRC, the Pacific Northwest Laboratory investigated whether such increased clearances would exacerbate tube fretting wear. Using a full-length scale model of a steam generator tube bundle, flow tests were conducted at an instrumented location through clearances representing as-built and post-cleaned tube conditions. Test results indicated little potential for increased tube wear as a result of chemical cleaning, under normal operating conditions at tube support locations similar to that tested

  7. Spontaneous breathing trial in T-tube negatively impact on autonomic modulation of heart rate compared with pressure support in critically ill patients.

    Science.gov (United States)

    Güntzel Chiappa, Adriana M; Chiappa, Gaspar R; Cipriano, Gerson; Moraes, Ruy S; Ferlin, Elton L; Borghi-Silva, Audrey; Vieira, Silvia R

    2017-07-01

    Spontaneous breathing with a conventional T-piece (TT) connected to the tracheal tube orotraqueal has been frequently used in clinical setting to weaning of mechanical ventilation (MV), when compared with pressure support ventilation (PSV). However, the acute effects of spontaneous breathing with TT versus PSV on autonomic function assessed through heart rate variability (HRV) have not been fully elucidated. The purpose of this study was to examine the acute effects of spontaneous breathing in TT vs PSV in critically ill patients. Twenty-one patients who had received MV for ≥ 48 h and who met the study inclusion criteria for weaning were assessed. Eligible patients were randomized to TT and PSV. Cardiorespiratory responses (respiratory rate -ƒ, tidal volume-V T , mean blood pressure (MBP) and diastolic blood pressure (DBP), end tidal dioxide carbone (P ET CO 2 ), peripheral oxygen saturation (SpO 2 ) and HRV indices in frequency domain (low-LF, high frequency (HF) and LF/HF ratio were evaluated. TT increased ƒ (20 ± 5 vs 25 ± 4 breaths/min, P<0.05), MBP (90 ± 14 vs 94 ± 18 mmHg, P<0.05), HR (90 ± 17 vs 96 ± 12 beats/min, P<0.05), P ET CO 2 (33 ± 8 vs 48 ± 10 mmHg, P<0.05) and reduced SpO 2 (98 ± 1.6 vs 96 ± 1.6%, P<0.05). In addition, LF increased (47 ± 18 vs 38 ± 12 nu, P<0.05) and HF reduced (29 ± 13 vs 32 ± 16 nu, P<0.05), resulting in higher LF/HF ratio (1.62 ± 2 vs 1.18 ± 1, P<0.05) during TT. Conversely, V T increased with PSV (0.58 ± 0.16 vs 0.50 ± 0.15 L, P<0.05) compared with TT. Acute effects of TT mode may be closely linked to cardiorespiratory mismatches and cardiac autonomic imbalance in critically ill patients. © 2015 John Wiley & Sons Ltd.

  8. Misdirected minitracheostomy tube

    Directory of Open Access Journals (Sweden)

    Ajmer Singh

    2017-01-01

    Full Text Available We report a patient who after an uneventful coronary artery bypass graft surgery and left ventricular aneurysmorrhaphy developed intracerebral hemorrhage and subsequently required minitracheostomy. Chest X-ray showed misdirected minitracheostomy tube facing upward toward the laryngeal opening which was repositioned using bronchoscope.

  9. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-01-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at…

  10. Thoughts of accelerator tubes

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators

  11. Thoughts of accelerator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Larson, J D

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators.

  12. Eustachian Tube Dysfunction

    Science.gov (United States)

    ... When it is inflated, the balloon opens a pathway for mucus and air to flow through the tube. This can help it function properly. FDA warning The U.S. Food and Drug Administration (FDA) advises against the use of ear candles. ...

  13. Tube-dwelling invertebrates

    NARCIS (Netherlands)

    Hölker, Franz; Vanni, Michael J.; Kuiper, Jan J.; Meile, Christof; Grossart, Hans Peter; Stief, Peter; Adrian, Rita; Lorke, Andreas; Dellwig, Olaf; Brand, Andreas; Hupfer, Michael; Mooij, Wolf M.; Nützmann, Gunnar; Lewandowski, Jörg

    2015-01-01

    There is ample evidence that tube-dwelling invertebrates such as chironomids significantly alter multiple important ecosystem functions, particularly in shallow lakes. Chironomids pump large water volumes, and associated suspended and dissolved substances, through the sediment and thereby compete

  14. Chest tube insertion

    Science.gov (United States)

    ... of your chest cavity. This is called the pleural space. It is done to allow your lungs to fully expand. ... pneumothorax ) Fluid buildup in the chest (called a pleural ... in the esophagus (the tube that allows food to go from the mouth ...

  15. Comprehensive characterization of measurement data gathered by the pressure tube to calandria tube gap probe

    Science.gov (United States)

    Shokralla, Shaddy Samir Zaki

    Multi-frequency eddy current measurements are employed in estimating pressure tube (PT) to calandria tube (CT) gap in CANDU fuel channels, a critical inspection activity required to ensure fitness for service of fuel channels. In this thesis, a comprehensive characterization of eddy current gap data is laid out, in order to extract further information on fuel channel condition, and to identify generalized applications for multi-frequency eddy current data. A surface profiling technique, generalizable to multiple probe and conductive material configurations has been developed. This technique has allowed for identification of various pressure tube artefacts, has been independently validated (using ultrasonic measurements), and has been deployed and commissioned at Ontario Power Generation. Dodd and Deeds solutions to the electromagnetic boundary value problem associated with the PT to CT gap probe configuration were experimentally validated for amplitude response to changes in gap. Using the validated Dodd and Deeds solutions, principal components analysis (PCA) has been employed to identify independence and redundancies in multi-frequency eddy current data. This has allowed for an enhanced visualization of factors affecting gap measurement. Results of the PCA of simulation data are consistent with the skin depth equation, and are validated against PCA of physical experiments. Finally, compressed data acquisition has been realized, allowing faster data acquisition for multi-frequency eddy current systems with hardware limitations, and is generalizable to other applications where real time acquisition of large data sets is prohibitive.

  16. ACCELEROMETERS IN FLOW FIELDS: A STRUCTURAL ANALYSIS OF THE CHOPPED DUMMY INPILE TUBE

    Energy Technology Data Exchange (ETDEWEB)

    Howard, T. K.; Marcum, W. R.; Latimer, G. D.; Weiss, A.; Jones, W. F.; Phillips, A. M.; Woolstenhulme, N.; Holdaway, K.; Campbell, J.

    2016-06-01

    Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s2 in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design.

  17. Viscous Design of TCA Configuration

    Science.gov (United States)

    Krist, Steven E.; Bauer, Steven X. S.; Campbell, Richard L.

    1999-01-01

    The goal in this effort is to redesign the baseline TCA configuration for improved performance at both supersonic and transonic cruise. Viscous analyses are conducted with OVERFLOW, a Navier-Stokes code for overset grids, using PEGSUS to compute the interpolations between overset grids. Viscous designs are conducted with OVERDISC, a script which couples OVERFLOW with the Constrained Direct Iterative Surface Curvature (CDISC) inverse design method. The successful execution of any computational fluid dynamics (CFD) based aerodynamic design method for complex configurations requires an efficient method for regenerating the computational grids to account for modifications to the configuration shape. The first section of this presentation deals with the automated regridding procedure used to generate overset grids for the fuselage/wing/diverter/nacelle configurations analysed in this effort. The second section outlines the procedures utilized to conduct OVERDISC inverse designs. The third section briefly covers the work conducted by Dick Campbell, in which a dual-point design at Mach 2.4 and 0.9 was attempted using OVERDISC; the initial configuration from which this design effort was started is an early version of the optimized shape for the TCA configuration developed by the Boeing Commercial Airplane Group (BCAG), which eventually evolved into the NCV design. The final section presents results from application of the Natural Flow Wing design philosophy to the TCA configuration.

  18. A Software Configuration Management Course

    DEFF Research Database (Denmark)

    Asklund, U.; Bendix, Lars Gotfred

    2003-01-01

    curriculum. It is either not taught at all or is just a minor part of a general course in software engineering. In this paper, we report on our experience with giving a full course entirely dedicated to Software Configuration Management topics and start a discussion of what ideally should be the goal......Software Configuration Management has been a big success in research and creation of tools. There are also many vendors in the market of selling courses to companies. However, in the education sector Software Configuration Management has still not quite made it - at least not into the university...

  19. A Software Configuration Management Course

    DEFF Research Database (Denmark)

    Asklund, U.; Bendix, Lars Gotfred

    2003-01-01

    Software Configuration Management has been a big success in research and creation of tools. There are also many vendors in the market of selling courses to companies. However, in the education sector Software Configuration Management has still not quite made it - at least not into the university...... curriculum. It is either not taught at all or is just a minor part of a general course in software engineering. In this paper, we report on our experience with giving a full course entirely dedicated to Software Configuration Management topics and start a discussion of what ideally should be the goal...

  20. Fractured tracheostomy tube presenting as a foreign body in a paediatric patient

    Science.gov (United States)

    Gupta, Suman Lata; Swaminathan, Srinivasan; Ramya, Ravivalar; Parida, Satyen

    2016-01-01

    Tracheostomy tube fracture and aspiration into the tracheobronchial tree leading to airway obstruction is a dangerous complication after tracheostomy. We report a case of a fractured tracheostomy tube in a 6-year-old child who had been maintained on a tracheostomy tube for the past 5 years. The tracheostomy tube got fractured at the junction of the tube and neck plate, and impacted in the trachea and right main bronchus. Rigid bronchoscopy performed through the tracheostomy stoma to retrieve the fractured tracheostomy tube and the anaesthetic management during the period are discussed. PMID:26957033

  1. Study of operational risk-based configuration control

    Energy Technology Data Exchange (ETDEWEB)

    Vesely, W E [Science Applications International Corp., Dublin, OH (United States); Samanta, P K; Kim, I S [Brookhaven National Lab., Upton, NY (United States)

    1991-08-01

    This report studies aspects of a risk-based configuration control system to detect and control plant configurations from a risk perspective. Configuration control, as the term is used here, is the management of component configurations to achieve specific objectives. One important objective is to control risk and safety. Another is to operate efficiently and make effective use of available resources. PSA-based evaluations are performed to study configuration to core-melt frequency and core-melt probability for two plants. Some equipment configurations can cause large core-melt frequency and there are a number of such configurations that are not currently controlled by technical specifications. However, the expected frequency of occurrence of the impacting configurations is small and the core-melt probability contributions are also generally small. The insights from this evaluation are used to develop the framework for an effective risk-based configuration control system. The focal points of such a system and the requirements for tools development for implementing the system are defined. The requirements of risk models needed for the system, and the uses of plant-specific data are also discussed. 18 refs., 25 figs., 10 tabs.

  2. Methodology for the thermal characterization of linear Fresnel collectors: Comparative of different configurations and working fluids

    Science.gov (United States)

    Montes, María José; Abbas, Rubén; Rovira, Antonio; Muñoz-Antón, Javier; Martínez-Val, José María

    2017-06-01

    Linear Fresnel collectors are becoming an attractive option to generate electricity from solar radiation. This paper is focused in the thermal performance of Fresnel collectors working with different heat transfer fluids: synthetic oil, water-steam, molten salt and air, also comparing the results of the Fresnel technology with those obtained in reference parabolic trough loops. Although there are two basic designs of the Fresnel receiver: multi-tube and single-tube with secondary concentrator, this work only studies in depth the single-tube option, as this design is more suitable for a proper comparison with parabolic troughs. The receiver in parabolic troughs has been modeled as an evacuated tube with a selective coating and a glass cover. For Fresnel receivers it has been simulated two different configurations: non-evacuated receiver, with a glass window at the cavity aperture and evacuated receiver, characterized by a tube with a glass cover and a selective coating.

  3. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  4. Rubens Flame-Tube Demonstration.

    Science.gov (United States)

    Ficken, George W.; Stephenson, Francis C.

    1979-01-01

    Investigates and explains the phenomenon associated with Rubens flame-tube demonstration, specifically the persistance of flames at regular intervals along the tube for few minutes after the gas is turned off. (GA)

  5. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  6. Shape configuration and category-specificity

    DEFF Research Database (Denmark)

    Gerlach, Christian; Law, I; Paulson, Olaf B.

    2006-01-01

    a recent account of category-specificity and lends support to the notion that category-specific impairments can occur for both natural objects and artefacts following damage to pre-semantic stages in visual object recognition. The implications of the present findings are discussed in relation to theories......We examined the neural correlates of visual shape configuration, the binding of local shape characteristics into wholistic object descriptions, by comparing the regional cerebral blood flow associated with recognition of outline drawings and fragmented drawings. We found no areas that responded...... more to fragmented drawings than to outline drawings even though fragmentation had a clear impact on recognition performance. Instead, a region extending from the inferior occipital gyri to the middle parts of the fusiform gyri was activated during shape configuration of both outline drawings...

  7. Enhancing operability and reliability through configuration management

    International Nuclear Information System (INIS)

    Hancock, L.R.

    1993-01-01

    This paper describes the evolution of plant design control techniques from the early 1970's to today's operating environment that demands accurate, up-to-date design data. This evolution of design control is responsible for the increasingly troublesome scenario of design data being very difficult to locate and when found, its credibility is questioned. The design information could be suspect because there are discrepancies between two or more source documents or there is a difference between the design documents and the physical configuration of the plant. This paper discusses the impact these design control problems are having on plant operations and presents common sense solutions for improving configuration management techniques to ultimately enhance operability and reliability

  8. Adjustable rare earth quadrupole drift tube magnets

    International Nuclear Information System (INIS)

    Feinberg, B.; Tanabe, J.; Halbach, K.; Koehler, G.; Green, M.I.

    1987-03-01

    A prototype permanent-magnet drift tube quadrupole with adjustable field strength has been constructed and tested. The magnet uses iron pole pieces to provide the required field shape along with rare earth permanent-magnet material (samarium cobalt) to energize the magnet. A unique feature of the configuration is the adjustability of the field, accomplished by rotating the outer rings consisting of permanent magnets and iron. In contrast with a previous prototype magnet, this new design uses ball bearings in place of slide bearings to eliminate potential failures. The rotation is now achieved with a bevel gear mechanism. The prototype design also incorporates a new drift tube shell vacuum seal to allow easy disassembly. Tests were made of the magnetic properties and the mechanical performance of this magnet. Field errors are extremely small, and the magnet passed an accelerated ten year lifetime test. It is planned to use this type of magnet to replace 24 of the SuperHILAC prestripper drift tubes

  9. Airport Configuration Prediction, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — There is presently poor knowledge throughout the National Airspace System (NAS) of the airport configurations currently in use at each airport. There is even less...

  10. Belene NPP project configuration management

    International Nuclear Information System (INIS)

    Matveev, A.

    2009-01-01

    The configuration management includes: change identification; change assessment; change coordination; change approval or rejection; Change introduction. One of the main tasks while implementing the above processes is the analysis of the effect of one change upon all the related elements

  11. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  12. Bayesian image restoration, using configurations

    OpenAIRE

    Thorarinsdottir, Thordis

    2006-01-01

    In this paper, we develop a Bayesian procedure for removing noise from images that can be viewed as noisy realisations of random sets in the plane. The procedure utilises recent advances in configuration theory for noise free random sets, where the probabilities of observing the different boundary configurations are expressed in terms of the mean normal measure of the random set. These probabilities are used as prior probabilities in a Bayesian image restoration approach. Estimation of the re...

  13. Magnetic Configuration Control of ITER Plasmas

    International Nuclear Information System (INIS)

    Albanese, R.; Artaserse, G.; Mattei, M.; Ambrosino, G.; Crisanti, F.; Tommasi, G. de; Fresa, R.; Portone, A.; Sartori, F.; Villone, F.

    2006-01-01

    The aim of this paper is to review the capability of the ITER Poloidal Field (PF) system of controlling the broad range of plasma configurations presently forecasted during ITER operation. The attention is focused on the axi-symmetric aspects of plasma magnetic configuration control since they pose the greatest challenges in terms of control power and they have the largest impact on machine capital cost. The paper is broadly divided in two main sections devoted, respectively, to open loop (feed-forward) and closed loop (feedback) control. In the first part of the study the PF system is assessed with respect to the initiation, ramp-up, sustained burn, ramp-down phases of the main plasma inductive scenario. The limiter-to-divertor configuration transition phase is considered in detail with the aim of assessing the PF capability to form an X-point at the lowest possible current and, therefore, to relax the thermal load on the limiter surfaces. Moreover, during the sustained burn it is important to control plasmas with a broad range of current density profiles. In the second part of the study the plasma vertical feedback control requirements are assessed in details, in particular for the high elongation configurations achievable during the early limiter-to-X point transition phase. Non-rigid plasma displacement models are used to assess the control system voltage and current requirements of different radial field control circuits obtained, for example, by connecting the outermost PF coils, some CS coils, coils sub-sections etc. At last, the main 3D effects of the vessel ports are modeled and their impact of vertical stabilization evaluated. (author)

  14. NEI You Tube Videos: Amblyopia

    Science.gov (United States)

    ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  15. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  16. Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings

    Directory of Open Access Journals (Sweden)

    Davide Papini

    2010-01-01

    Different condenser tube arrangements have been developed for applications to the next generation NPPs. The two most used configurations, namely, horizontal and vertical tube condensers, are thoroughly investigated in this paper. Several thermal-hydraulic features were explored, being the analysis mainly devoted to the description of the best-estimate correlations and models for heat transfer coefficient prediction. In spite of a more critical behaviour concerning thermal expansion issues, vertical tube condensers offer remarkably better thermal-hydraulic performances. An experimental validation of the vertical tube correlations is provided by PERSEO facility (SIET labs, Piacenza, showing a fairly good agreement.

  17. Neutron image intensifier tubes

    International Nuclear Information System (INIS)

    Verat, M.; Rougeot, H.; Driard, B.

    1983-01-01

    The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter: in the direct method, the film is exposed during the time that the object is irradiated with neutrons; in the transfer method, the film is exposed after the irradiation of the object with neutrons. In industrial non-destructive testing, when many identical objects have to be checked, these techniques have several disadvantages. Non-destructive testing systems without these disadvantages can be constructed around neutron-image intensifier tubes. A description and the operating characteristics of neutron-image intensifier tubes are given. (Auth.)

  18. Neural tube defects

    Directory of Open Access Journals (Sweden)

    M.E. Marshall

    1981-09-01

    Full Text Available Neural tube defects refer to any defect in the morphogenesis of the neural tube, the most common types being spina bifida and anencephaly. Spina bifida has been recognised in skeletons found in north-eastern Morocco and estimated to have an age of almost 12 000 years. It was also known to the ancient Greek and Arabian physicians who thought that the bony defect was due to the tumour. The term spina bifida was first used by Professor Nicolai Tulp of Amsterdam in 1652. Many other terms have been used to describe this defect, but spina bifida remains the most useful general term, as it describes the separation of the vertebral elements in the midline.

  19. Should Children With Cleft Palate Receive Early Long-Term Tympanostomy Tubes: One Institution's Experience.

    Science.gov (United States)

    Shaffer, Amber D; Ford, Matthew D; Choi, Sukgi S; Jabbour, Noel

    2018-03-01

    To determine whether children with cleft palate might benefit from early long-term tympanostomy tubes with the hypothesis that receiving multiple tubes is associated with shorter duration of first tubes. Retrospective cohort study. Tertiary care children's hospital. Records from 401 consecutive children with cleft palate ± cleft lip, born April 2005 to April 2010, were reviewed. After exclusion of children with cleft repair at an outside hospital, no follow-up after 5 years of age, intact secondary palate, no tubes, or tube replacement at palatoplasty, 105 children remained. Number of tubes. Armstrong grommet tubes were placed at a median age of 6.7 months (range 2.3-19.6 months). Tubes were replaced in 55.3% of patients, with 34.0% receiving ≥3 sets. Duration of first tubes was significantly longer for children with 1 set of tubes compared with those with multiple sets (median 26 vs 19 months, P = .004). Otorrhea, but not perforation, was associated with longer duration of first tubes (median 27 vs 20.5 months, P = .028). Cleft type did not impact the proportion of patients with multiple tubes. Median age at last tube placement for children with multiple tubes was 5.0 years (range 1.9-8.7 years). Short duration of first tubes is associated with receiving multiple tubes. Because most patients require repeat tubes and many require tubes until school age, there is a significant need for controlled, prospective trials of early long-term tube placement in this population.

  20. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  1. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  2. Falling film evaporation on a tube bundle with plain and enhanced tubes

    International Nuclear Information System (INIS)

    Habert, M.

    2009-04-01

    The complexities of two-phase flow and evaporation on a tube bundle present important problems in the design of heat exchangers and the understanding of the physical phenomena taking place. The development of structured surfaces to enhance boiling heat transfer and thus reduce the size of evaporators adds another level of complexity to the modeling of such heat exchangers. Horizontal falling film evaporators have the potential to be widely used in large refrigeration systems and heat pumps, in the petrochemical industry and for sea water desalination units, but there is a need to improve the understanding of falling film evaporation mechanisms to provide accurate thermal design methods. The characterization of the effect of enhanced surfaces on the boiling phenomena occurring in falling film evaporators is thus expected to increase and optimize the performance of a tube bundle. In this work, the existing LTCM falling film facility was modified and instrumented to perform falling film evaporation measurements on single tube row and a small tube bundle. Four types of tubes were tested including: a plain tube, an enhanced condensing tube (Gewa-C+LW) and two enhanced boiling tubes (Turbo-EDE2 and Gewa-B4) to extend the existing database. The current investigation includes results for two refrigerants, R134a and R236fa, at a saturation temperature of T sat = 5 °C, liquid film Reynolds numbers ranging from 0 to 3000, at heat fluxes between 20 and 60 kW/m² in pool boiling and falling film configurations. Measurements of the local heat transfer coefficient were obtained and utilized to improve the current prediction methods. Finally, the understanding of the physical phenomena governing the falling film evaporation of liquid refrigerants has been improved. Furthermore, a method for predicting the onset of dry patch formation has been developed and a local heat transfer prediction method for falling film evaporation based on a large experimental database has been proposed

  3. Conceptual design of a bayonet-tube steam generator for the ALFRED lead-cooled reactor

    International Nuclear Information System (INIS)

    Damiani, Lorenzo; Montecucco, Massimo; Pini Prato, Alessandro

    2013-01-01

    Highlights: • Conceptual design of a bayonet-tube steam generator for a lead-cooled reactor demonstrator. • Steady-state simulations effected through RELAP 5. • Performance evaluation of the steam generator for different configurations of the bayonet tubes. - Abstract: The present paper is centred on the design of a bayonet tube steam generator, fundamental part of an innovative lead-cooled fast nuclear reactor (LFR). The construction of the LFR is the main objective of the European project named LEADER, of which Ansaldo Nucleare is an important member. The steam generator described in this paper is expected to be installed in a 300 MW thermal power demonstrator plant, named ALFRED. The investigations carried out in this work through the RELAP 5 code have first faced the sizing of the single bayonet tube and then the design of the whole heat exchanger. The configurations of the four coaxial tubes composing the single bayonet, the length of the bayonets and the materials employed have been investigated; the final heat exchanger configuration provides 510 bayonet tubes of 6 m active length with a thermal insulation between the inner descending tube and the rising annulus, assured by a special extremely insulating paint. The whole steam generator has shown its capability to reach the required exchanged power of 37.5 MW th , providing as output dry superheated steam at the desired temperature of 450 °C

  4. BAYESIAN IMAGE RESTORATION, USING CONFIGURATIONS

    Directory of Open Access Journals (Sweden)

    Thordis Linda Thorarinsdottir

    2011-05-01

    Full Text Available In this paper, we develop a Bayesian procedure for removing noise from images that can be viewed as noisy realisations of random sets in the plane. The procedure utilises recent advances in configuration theory for noise free random sets, where the probabilities of observing the different boundary configurations are expressed in terms of the mean normal measure of the random set. These probabilities are used as prior probabilities in a Bayesian image restoration approach. Estimation of the remaining parameters in the model is outlined for salt and pepper noise. The inference in the model is discussed in detail for 3 X 3 and 5 X 5 configurations and examples of the performance of the procedure are given.

  5. Projective configurations in projectivegeometrical drawings

    Directory of Open Access Journals (Sweden)

    Ivashchenko Andrey Viktorovich

    2015-05-01

    Full Text Available The article focuses on the optimization of the earlier discussed computer method of obtaining new forms of polyhedra based on projective geometry drawings (trace Diagrams.While working on getting new multifaceted forms by projective geometry methods based on the well-known models of polyhedra on the first stage of the work it is required to calculate the parameters of projective geometry drawings, and then to build them. This is an often used apparatus of analytical geometry. According to it, at first the parameters of the polyhedron (core system of planes are calculated, then we obtain the equation of the plane of the face of the polyhedron, and finally we obtain the equations of lines the next plane faces on the selected curve plane. At each stage of application such a method requires the use of the algorithms of floating point arithmetic, on the one hand, leads to some loss of accuracy of the results and, on the other hand, the large amount of computer time to perform these operations in comparison with integer arithmetic operations.The proposed method is based on the laws existing between the lines that make up the drawing - the known configurations of projective geometry (complete quadrilaterals, configuration of Desargues, Pappus et al..The authors discussed in detail the analysis procedure of projective geometry drawing and the presence of full quadrilaterals, Desargues and Pappus configurations in it.Since the composition of these configurations is invariant with respect to projective change of the original nucleus, knowing them, you can avoid the calculations when solving the equations for finding direct projective geometry drawing analytically, getting them on the basis of belonging to a particular configuration. So you can get a definite advantage in accuracy of the results, and in the cost of computer time. Finding these basic configurations significantly enriches the set of methods and the use of projective geometry drawings.

  6. Knowledge Engineering for Embedded Configuration

    DEFF Research Database (Denmark)

    Oddsson, Gudmundur Valur

    2008-01-01

    usability of the installation. In our case, we have rationalized that this should be done with embedded configuration, and the expected result is enhanced usability. The suggested method is deeply rooted in system theory. It draws on the emergent properties expected from the system, and tries to embed...... step can be said to be two-fold: first, to construct a system based on this philosophy and to show that it actually leads to the expected results. And second, to further develop the modelling tools and methods for supporting the making of embedded configuration systems, or in essence, a distributed...

  7. Bayesian image restoration, using configurations

    DEFF Research Database (Denmark)

    Thorarinsdottir, Thordis Linda

    2006-01-01

    In this paper, we develop a Bayesian procedure for removing noise from images that can be viewed as noisy realisations of random sets in the plane. The procedure utilises recent advances in configuration theory for noise free random sets, where the probabilities of observing the different boundary...... configurations are expressed in terms of the mean normal measure of the random set. These probabilities are used as prior probabilities in a Bayesian image restoration approach. Estimation of the remaining parameters in the model is outlined for the salt and pepper noise. The inference in the model is discussed...

  8. Bayesian image restoration, using configurations

    DEFF Research Database (Denmark)

    Thorarinsdottir, Thordis

    In this paper, we develop a Bayesian procedure for removing noise from images that can be viewed as noisy realisations of random sets in the plane. The procedure utilises recent advances in configuration theory for noise free random sets, where the probabilities of observing the different boundary...... configurations are expressed in terms of the mean normal measure of the random set. These probabilities are used as prior probabilities in a Bayesian image restoration approach. Estimation of the remaining parameters in the model is outlined for salt and pepper noise. The inference in the model is discussed...

  9. Instance-specific algorithm configuration

    CERN Document Server

    Malitsky, Yuri

    2014-01-01

    This book presents a modular and expandable technique in the rapidly emerging research area of automatic configuration and selection of the best algorithm for the instance at hand. The author presents the basic model behind ISAC and then details a number of modifications and practical applications. In particular, he addresses automated feature generation, offline algorithm configuration for portfolio generation, algorithm selection, adaptive solvers, online tuning, and parallelization.    The author's related thesis was honorably mentioned (runner-up) for the ACP Dissertation Award in 2014,

  10. Remarks on impact shearing

    Science.gov (United States)

    Klepaczko, J. R.

    1998-10-01

    A review is presented on recent progress in shear testing of materials at high and very high strain rates. Some experimental techniques are discussed which allow for materials testing in shear up to 10 6 ls. More detailed informations are provided on experimental techniques based on the Modified Double Shear specimen loaded by direct impact. This technique has been applied so far to test a variety of materials, including construction, armor and inoxidable steels, and also aluminum alloys. The double shear configuration has also been applied to test sheet metals, mostly used in the automotive industry, in a wide range of strain rates. Details of both techniques, including measuring systems and elastic wave propagation in tubes, are discussed. In addition, a new experimental configuration which can be applied for experimental studies of adiabatic shear propagation and high speed machining is discussed. The role of adiabatic heating at different rates of shearing is also discussed, including transition from pure isothermal to pure adiabatic deformation. It appears that the initial impact velocity is an important parameter in development of plastic localization. Finally, a new development is discussed in determination of the Critical Impact Velocity in shear. A comparison is shown between recent experimental findings and a simple analytic estimation. The CIV in shear is a certain mode of adiabatic failure which occurs at relatively high shear velocities of adjacent material layers. Numerical simulations support the existence of the CIV in shear which can be recognized to some extent as a material constant.

  11. Study of Permanent Magnet Focusing for Astronomical Camera Tubes

    Science.gov (United States)

    Long, D. C.; Lowrance, J. L.

    1975-01-01

    A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

  12. Performance characterization of the TRW 35K pulse tube cooler

    International Nuclear Information System (INIS)

    Collins, S.A.; Johnson, D.L.; Smedley, G.T.; Ross, R.G. Jr.

    1996-01-01

    The TRW 35K pulse tube cooler is configured as an integral cooler, with the pulse tube attached perpendicular to a pair of compressors operating into a common compression chamber. The cooler was optimized for 35K operation and has a nominal cooling capacity of 850 mW at 35 K with a cooler input power of 200 W. It also provides 2 W of cooling at 60 K for 90 W of input power. The cooler was extensively characterized by JPL, measuring the thermal performance and the cooler-generated vibration and EMI as a function of piston stroke and offset position. The thermal performance was found to be quite sensitive to the piston offset position. The pulse tube parasitic conduction levels were also measured and shown to have a strong angular dependence relative to gravity. Magnetic shielding studies were performed to examine radiated magnetic emission levels from compressors with and without shielding

  13. Ion beam characteristics of a gas filled accelerator tube

    International Nuclear Information System (INIS)

    Berg, R.S.; Bickes, R.W. Jr.; Boers, J.E.; Shope, L.A.

    1980-01-01

    A gas filled tube used to produce a pulsed neutron flux with the D(T, 4 He)n reaction is described. Deuterium and tritium ions generated in a reflex discharge are extracted and accelerated to 100 keV by means of an accelerator electrode onto a deutero-tritide target electrode. The electrodes are designed to focus the ion beam onto the target. Total tube currents consisting of extracted ions, unsuppressed secondary electrons, and ions generated by interactions with the background gas are typically 100mA. Characteristics of the extracted ion beam are discussed. Accelerating voltages greater than 50kV are required to focus the beam through the accelerator aperture for configurations that give beams with the proper energy density at the target. The perveance of the beam is defined. Maximum perveance values are 2 to 10 nanopervs. Tube focussing and neutron production characteristics are described

  14. Simulation of extrusion of high density polyethylene tubes

    Directory of Open Access Journals (Sweden)

    Koutelieris Antonios

    2017-01-01

    Full Text Available The production of extruded polyethylene films rods, tubes and pipes is a typical industrial process that has been extensively investigated over many years. In this study the extrusion of High Density Polyethylene (HDPE tubes was simulated by using the 3D finite element simulation software StarCCM+®. The simulation was applied in order to examine the influence of design and operational parameters on the characteristics and the soundness of the tube and for optimizing the overall quality of the product. Two alternative die configurations were studied; one with a four inputs head and the other with an eight inputs head. From the results obtained it is concluded that extrusion with the eight inputs head die design results in better overall pipe quality; this design was implemented successfully in an industrial production line.

  15. Optical effects on neutron guide tubes produced by collimation

    International Nuclear Information System (INIS)

    Margaca, F.M.A.; Falcao, A.N.; Sequeira, A.D.; Salgado, J.F.

    1991-01-01

    The collimation of a neutron beam carried by a guide tube is shown to procedure extensive regions of umbra and penumbra on the inner walls of the guide tube whenever a diaphragm is used at the exit. The region of umbra renders useless a certain length of the guide-tube end while in the region of penumbra the guide exhibits a faint luminosity. These optical effects are particularly important for stringent collimation. It is shown that these effects render impossible the implementation of the 'equal-flight-paths' design currently used for small-angle neutron scattering instruments, which use guide segments and a diaphragm in the collimation assembly. As a consequence, these operate most of the time in strongly unmatched configurations. It is shown that the optimized design formerly proposed by the authors, in which, whenever possible, the full luminous source area is used, not only avoids the optical effects mentioned but also guarantees the highest detector count rate. (orig.)

  16. Stress-Assisted Corrosion in Boiler Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Preet M Singh; Steven J Pawel

    2006-05-27

    A number of industrial boilers, including in the pulp and paper industry, needed to replace their lower furnace tubes or decommission many recovery boilers due to stress-assisted corrosion (SAC) on the waterside of boiler tubes. More than half of the power and recovery boilers that have been inspected reveal SAC damage, which portends significant energy and economic impacts. The goal of this project was to clarify the mechanism of stress-assisted corrosion (SAC) of boiler tubes for the purpose of determining key parameters in its mitigation and control. To accomplish this in-situ strain measurements on boiler tubes were made. Boiler water environment was simulated in the laboratory and effects of water chemistry on SAC initiation and growth were evaluated in terms of industrial operations. Results from this project have shown that the dissolved oxygen is single most important factor in SAC initiation on carbon steel samples. Control of dissolved oxygen can be used to mitigate SAC in industrial boilers. Results have also shown that sharp corrosion fatigue and bulbous SAC cracks have similar mechanism but the morphology is different due to availability of oxygen during boiler shutdown conditions. Results are described in the final technical report.

  17. Fracture toughness determination in steam generator tubes

    International Nuclear Information System (INIS)

    Bergant M; Yawny, A; Perez Ipina, J

    2012-01-01

    The assessment of the structural integrity of steam generator tubes in nuclear power plants deserved increasing attention in the last years due to the negative impact related to their failures. In this context, elastic plastic fracture mechanics (EPFM) methodology appears as a potential tool for the analysis. The application of EPFM requires, necessarily, knowledge of two aspects, i.e., the driving force estimation in terms of an elastic plastic toughness parameter (e.g., J) and the experimental measurement of the fracture toughness of the material (e.g., the material J-resistance curve). The present work describes the development of a non standardized experimental technique aimed to determine J-resistance curves for steam generator tubes with circumferential through wall cracks. The tubes were made of Incoloy 800 (Ni: 30.0-35.0; Cr: 19.0-23.0; Fe: 35.5 min, % in weight). Due to its austenitic microstructure, this alloy shows very high toughness and is widely used in applications where a good corrosion resistance in aqueous environment or an excellent oxidation resistance in high temperature environment is required. Finally, a procedure for the structural integrity analysis of steam generator tubes with crack-like defects, based on a FAD diagram (Failure Assessment Diagram), is briefly described (author)

  18. Flow-induced decentering and tube support interaction for steam generator tubes: experiment and physical interpretation

    International Nuclear Information System (INIS)

    Gay, N.; Granger, S.

    1992-11-01

    Maintaining PWR components under reliable operating conditions requires a complex design to prevent various damaging processes including flow-induced vibration and wear mechanisms. To improve the prediction of tube/support interaction and wear in PWR components, EDF has undertaken a comprehensive program oriented to both experimental and computational studies. The present paper illustrates one aspect of this program, related to the determination of contact forces between steam generator tubes and anti-vibration bars (AVBs). The dynamic, nonlinear behavior of a U-tube excited by an air cross-flow is investigated on the CLAVECIN experiment. Interesting and rather unexpected results have been obtained, by varying clearances and flow velocities. The paper is focused on four main points: (i) the originality of the experiment with a force measurement device located in flow; (ii) the importance of a refined data processing for accurately measuring contact forces; (iii) the presentation of the unexpected phenomena revealed in the CLAVECIN experiment, i.e. a flow-induced decentering of the tube which changed the initial tube/AVB clearance, and the consequences on tube/support interaction; (iv) the influence of the actual tube/support clearance in flow on wear mechanisms. The work, presented in the second part of this paper, concentrates exclusively on the physical interpretation of the flow-induced decentering phenomenon and on the theoretical analysis of its consequences on dynamic tube/support interaction. We show that the flow-induced decentering phenomenon can be generated by an unstable quasi-static coupling between the flexible tube and the confined flow, in the vicinity of the support system. This phenomenon is not specific to the CLAVECIN tests and it can be expected every time that a movable obstacle is subjected to confined flow. Moreover, in single-sided impacting conditions, the theoretical analysis confirms the linear relation, found in the CLAVECIN tests

  19. Computational methods for stellerator configurations

    International Nuclear Information System (INIS)

    Betancourt, O.

    1989-01-01

    This project consists of two parallel objectives. On the one hand, computational techniques for three dimensional magnetic confinement configurations were developed or refined and on the other hand, this new techniques were applied to the solution of practical fusion energy problems or the techniques themselves were transferred to other fusion researcher for practical use in the field

  20. Equilibrium: three-dimensional configurations

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    This chapter considers toroidal MHD configurations that are inherently three-dimensional. The motivation for investigation such complicated equilibria is that they possess the potential for providing toroidal confinement without the need of a net toroidal current. This leads to a number of advantages with respect to fusion power generation. First, the attractive feature of steady-state operation becomes more feasible since such configurations no longer require a toroidal current transformer. Second, with zero net current, one potentially dangerous class of MHD instabilities, the current-driven kink modes, is eliminated. Finally, three-dimensional configurations possess nondegenerate flux surfaces even in the absence of plasma pressure and plasma current. Although there is an enormous range of possible three-dimensional equilibria, the configurations of interest are accurately described as axisymmetric tori with superimposed helical fields; furthermore, they possess no net toroidal current. Instead, two different and less obvious restoring forces are developed: the helical sideband force and the toroidal dipole current force. Each is discussed in detail in Chapter 7. A detailed discussion of the parallel current constraint, including its physical significance, is given in section 7.2. A general analysis of helical sideband equilibria, along with a detailed description of the Elmo bumpy torus, is presented in sections 7.3 and 7.4. A general description of toroidal dipole-current equilibria, including a detailed discussion of stellarators, heliotrons, and torsatrons, is given in sections 7.5 and 7.6

  1. Environmental restoration project configuration control

    International Nuclear Information System (INIS)

    Hutterman, L.L.

    1991-01-01

    This paper provides an overview of the approach that Westinghouse Idaho Nuclear Company, Inc. (WINCO) is using for the implementation of the configuration control requirements for a major system acquisition under the guidance of US Department of Energy (DOE) Order 4700.1, open-quotes Project Management System,close quotes for environmental restoration. The two major features of the WINCO environmental restoration approach relate to (1) the product and (2) the maintenance of the baseline for many sites in different phases at the same time. Historically, a project has typically produced a product. Environmental restoration in some ways produces no typical project product. Essentially, what is produced and what configuration control management is exercised on is one of the following: (1) the development of clean dirt, (2) the documentation to support clean dirt, or (3) the track record of each of the sites. It is the latter approach that this paper deals with. This approach is unique in that there are four baselines [cost, schedule, scope, and technical (the track record product)] rather than the typical three. This is essential in configuration management due to the lack of a uniquely identifiable product for each site. Essentially, the philosophy behind the four-part configuration controls allows the technical baseline to fulfill the function typically met by the identifiable product

  2. Product Configuration Systems and Productivity

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Twelve companies have been interviewed with the purpose to get information about technical, economic and organisational matters in respect of Product Configuration Systems (PCS).Combinations of qualitative interviews and quantitative scoring have been used in ranking expected and realized results...

  3. CONFIGURATION-SPACE YAKUBOVSKY CALCULATIONS

    NARCIS (Netherlands)

    SCHELLINGERHOUT, NW; SCHUT, JJ; KOK, LP

    1992-01-01

    The ground-state energy of a system consisting of four identical bosons or fermions is calculated using the Yakubovsky differential equations which are formulated in configuration space. The solution is restricted to include s waves only. Spline approximation and orthogonal collocation reduce the

  4. NCCDS configuration management process improvement

    Science.gov (United States)

    Shay, Kathy

    1993-01-01

    By concentrating on defining and improving specific Configuration Management (CM) functions, processes, procedures, personnel selection/development, and tools, internal and external customers received improved CM services. Job performance within the section increased in both satisfaction and output. Participation in achieving major improvements has led to the delivery of consistent quality CM products as well as significant decreases in every measured CM metrics category.

  5. Kramers Pairs in configuration interaction

    DEFF Research Database (Denmark)

    Avery, John Scales; Avery, James Emil

    2003-01-01

    The theory of symmetry-preserving Kramers pair creation operators is reviewed and formulas for applying these operators to configuration interaction calculations are derived. A new and more general type of symmetry-preserving pair creation operator is proposed and shown to commute with the total...

  6. Typology of Product Configuration Systems

    DEFF Research Database (Denmark)

    Jensen, Klaes Ladeby; Edwards, Kasper; Haug, Anders

    2007-01-01

    Many organisations are moving from mass production to mass customization. Product configuration systems (PCS) are increasingly seen as an interesting option for firms who wish to pursue a strategy with a high degree of product variance while retaining a low cost of specifying the product. To become...

  7. Shock tube Multiphase Experiments

    Science.gov (United States)

    Middlebrooks, John; Allen, Roy; Paudel, Manoj; Young, Calvin; Musick, Ben; McFarland, Jacob

    2017-11-01

    Shock driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching practical applications in engineering and science. The instability is present in high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase interface is impulsively accelerated by the passage of a shockwave. It is similar in development to the Richtmyer-Meshkov (RM) instability however, particle-to-gas coupling is the driving mechanism of the SDMI. As particle effects such as lag and phase change become more prominent, the SDMI's development begins to significantly deviate from the RM instability. We have developed an experiment for studying the SDMI in our shock tube facility. In our experiments, a multiphase interface is created using a laminar jet and flowed into the shock tube where it is accelerated by the passage of a planar shockwave. The interface development is captured using CCD cameras synchronized with planar laser illumination. This talk will give an overview of new experiments conducted to examine the development of a shocked cylindrical multiphase interface. The effects of Atwood number, particle size, and a second acceleration (reshock) of the interface will be discussed.

  8. Combustion, cofiring and emissions characteristics of torrefied biomass in a drop tube reactor

    International Nuclear Information System (INIS)

    Ndibe, Collins; Maier, Jörg; Scheffknecht, Günter

    2015-01-01

    The study investigates cofiring characteristics of torrefied biomass fuels at 50% thermal shares with coals and 100% combustion cases. Experiments were carried out in a 20 kW, electrically heated, drop-tube reactor. Fuels used include a range of torrefied biomass fuels, non-thermally treated white wood pellets, a high volatile bituminous coal and a lignite coal. The reactor was maintained at 1200 °C while the overall stoichiometric ratio was kept constant at 1.15 for all combustion cases. Measurements were performed to evaluate combustion reactivity, emissions and burn-out. Torrefied biomass fuels in comparison to non-thermally treated wood contain a lower amount of volatiles. For the tests performed at a similar particle size distribution, the reduced volatile content did not impact combustion reactivity significantly. Delay in combustion was only observed for test fuel with a lower amount of fine particles. The particle size distribution of the pulverised grinds therefore impacts combustion reactivity more. Sulphur and nitrogen contents of woody biomass fuels are low. Blending woody biomass with coal lowers the emissions of SO 2 mainly as a result of dilution. NO X emissions have a more complex dependency on the nitrogen content. Factors such as volatile content of the fuels, fuel type, furnace and burner configurations also impact the final NO X emissions. In comparison to unstaged combustion, the nitrogen conversion to NO X declined from 34% to 9% for air-staged co-combustion of torrefied biomass and hard coal. For the air-staged mono-combustion cases, nitrogen conversion to NO X declined from between 42% and 48% to about 10%–14%. - Highlights: • Impact of torrefaction on cofiring was studied at high heating rates in a drop tube. • Cofiring of torrefied biomasses at high thermal shares (50% and higher) is feasible. • Particle size impacts biomass combustion reactivity more than torrefaction. • In a drop tube reactor, torrefaction has no negative

  9. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  10. Failure analysis of boiler tube

    International Nuclear Information System (INIS)

    Mehmood, K.; Siddiqui, A.R.

    2007-01-01

    Boiler tubes are energy conversion components where heat energy is used to convert water into high pressure superheated steam, which is then delivered to a turbine for electric power generation in thermal power plants or to run plant and machineries in a process or manufacturing industry. It was reported that one of the tubes of a fire-tube boiler used in a local industry had leakage after the formation of pits at the external surface of the tube. The inner side of the fire tube was working with hot flue gasses with a pressure of 10 Kg/cm/sup 2/ and temperature 225 degree C. The outside of the tube was surrounded by feed water. The purpose of this study was to determine the cause of pits developed at the external surface of the failed boiler tube sample. In the present work boiler tube samples of steel grade ASTM AI61/ASTM A192 were analyzed using metallographic analysis, chemical analysis, and mechanical testing. It was concluded that the appearance of defects on the boiler tube sample indicates cavitation type corrosion failure. Cavitation damage superficially resembled pitting, but surface appeared considerably rougher and had many closely spaced pits. (author)

  11. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  12. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  13. A Kolsky tension bar technique using a hollow incident tube

    Science.gov (United States)

    Guzman, O.; Frew, D. J.; Chen, W.

    2011-04-01

    Load control of the incident pulse profiles in compression Kolsky bar experiments has been widely used to subject the specimen to optimal testing conditions. Tension Kolsky bars have been used to determine dynamic material behavior since the 1960s with limited capability to shape the loading pulses due to the pulse-generating mechanisms. We developed a modified Kolsky tension bar where a hollow incident tube is used to carry the incident stress waves. The incident tube also acts as a gas gun barrel that houses the striker for impact. The main advantage of this new design is that the striker impacts on an impact cap of the incident tube. Compression pulse shapers can be attached to the impact cap, thus fully utilizing the predictive compression pulse-shaping capability in tension experiments. Using this new testing technique, the dynamic tensile material behavior for Al 6061-T6511 and TRIP 800 (transformation-induced plasticity) steel has been obtained.

  14. A Kolsky tension bar technique using a hollow incident tube

    International Nuclear Information System (INIS)

    Guzman, O; Frew, D J; Chen, W

    2011-01-01

    Load control of the incident pulse profiles in compression Kolsky bar experiments has been widely used to subject the specimen to optimal testing conditions. Tension Kolsky bars have been used to determine dynamic material behavior since the 1960s with limited capability to shape the loading pulses due to the pulse-generating mechanisms. We developed a modified Kolsky tension bar where a hollow incident tube is used to carry the incident stress waves. The incident tube also acts as a gas gun barrel that houses the striker for impact. The main advantage of this new design is that the striker impacts on an impact cap of the incident tube. Compression pulse shapers can be attached to the impact cap, thus fully utilizing the predictive compression pulse-shaping capability in tension experiments. Using this new testing technique, the dynamic tensile material behavior for Al 6061-T6511 and TRIP 800 (transformation-induced plasticity) steel has been obtained

  15. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  16. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  17. Nasogastric tube syndrome induced by an indwelling long intestinal tube.

    Science.gov (United States)

    Sano, Naoki; Yamamoto, Masayoshi; Nagai, Kentaro; Yamada, Keiichi; Ohkohchi, Nobuhiro

    2016-04-21

    The nasogastric tube (NGT) has become a frequently used device to alleviate gastrointestinal symptoms. Nasogastric tube syndrome (NTS) is an uncommon but potentially life-threatening complication of an indwelling NGT. NTS is characterized by acute upper airway obstruction due to bilateral vocal cord paralysis. We report a case of a 76-year-old man with NTS, induced by an indwelling long intestinal tube. He was admitted to our hospital for treatment of sigmoid colon cancer. He underwent sigmoidectomy to release a bowel obstruction, and had a long intestinal tube inserted to decompress the intestinal tract. He presented acute dyspnea following prolonged intestinal intubation, and bronchoscopy showed bilateral vocal cord paralysis. The NGT was removed immediately, and tracheotomy was performed. The patient was finally discharged in a fully recovered state. NTS be considered in patients complaining of acute upper airway obstruction, not only with a NGT inserted but also with a long intestinal tube.

  18. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-12-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at the point where sound is perceived to have maximum loudness, or at the point where the amplitude of the standing wave has maximum value, namely an antinode. An antinode coincides with the position of the tuning fork, beyond the end of the air column, which consequently introduces an end correction. One way to minimize this end correction is to measure the distance between consecutive antinodes.

  19. Piezoelectric Rotary Tube Motor

    Science.gov (United States)

    Fisher, Charles D.; Badescu, Mircea; Braun, David F.; Culhane, Robert

    2011-01-01

    A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

  20. Pressure tube reactor

    International Nuclear Information System (INIS)

    Matsumoto, Tomoyuki; Fujino, Michihira.

    1980-01-01

    Purpose: To equalize heavy water flow distribution by providing a nozzle for externally injecting heavy water from a vibration preventive plate to the upper portion to feed the heavy water in a pressure tube reactor and swallowing up heavy water in a calandria tank to supply the heavy water to the reactor core above the vibration preventive plate. Constitution: A moderator injection nozzle is mounted on the inner wall of a calandria tank. Heavy water is externally injected above the vibration preventive plate, and heavy water in the calandria tank is swallowed up to supply the heavy water to the core reactor above the vibration preventive plate. Therefore, the heavy water flow distribution can be equalized over the entire reactor core, and the distribution of neutron absorber dissolved in the heavy water is equalized. (Yoshihara, H.)

  1. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  2. Configuring Symantec AntiVirus

    CERN Document Server

    Shimonski, Robert

    2003-01-01

    This is the only book that will teach system administrators how to configure, deploy, and troubleshoot Symantec Enterprise Edition in an enterprise network. The book will reflect Symantec''s philosophy of "Centralized Antivirus Management." For the same reasons that Symantec bundled together these previously separate products, the book will provide system administrators with a holistic approach to defending their networks from malicious viruses. This book will also serve as a Study Guide for those pursuing Symantec Product Specialist Certifications.Configuring Symantec AntiVirus Enterprise Edition contains step-by-step instructions on how to Design, implement and leverage the Symantec Suite of products in the enterprise.ØFirst book published on market leading product and fast-growing certification. Despite the popularity of Symantec''s products and Symantec Product Specialist certifications, there are no other books published or announced.ØLess expensive substitute for costly on-sight training. Symantec off...

  3. Automatic creation of simulation configuration

    International Nuclear Information System (INIS)

    Oudot, G.; Poizat, F.

    1993-01-01

    SIPA, which stands for 'Simulator for Post Accident', includes: 1) a sophisticated software oriented workshop SWORD (which stands for 'Software Workshop Oriented towards Research and Development') designed in the ADA language including integrated CAD system and software tools for automatic generation of simulation software and man-machine interface in order to operate run-time simulation; 2) a 'simulator structure' based on hardware equipment and software for supervision and communications; 3) simulation configuration generated by SWORD, operated under the control of the 'simulator structure' and run on a target computer. SWORD has already been used to generate two simulation configurations (French 900 MW and 1300 MW nuclear power plants), which are now fully operational on the SIPA training simulator. (Z.S.) 1 ref

  4. Microsoft System Center Configuration Manager

    CERN Document Server

    Sandbu, Marius

    2013-01-01

    This book is a step-by-step tutorial that guides you through the key steps in implementing best solutions for high availability and performance tuning. It is split into two distinct approaches: client and site side HA and optimization.Microsoft SCCM High Availability and Performance Tuning is for IT professionals and consultants working with Configuration Manager who wish to learn the skills to deploy a redundant and scalable solution.

  5. Theory of field reversed configurations

    International Nuclear Information System (INIS)

    Steinhauer, L.C.

    1990-01-01

    This final report surveys the results of work conducted on the theory of field reversed configurations. This project has spanned ten years, beginning in early 1980. During this period, Spectra Technology was one of the leading contributors to the advances in understanding FRC. The report is organized into technical topic areas, FRC formation, equilibrium, stability, and transport. Included as an appendix are papers published in archival journals that were generated in the course of this report. 33 refs

  6. Drupal 7 Multi Sites Configuration

    CERN Document Server

    Butcher, Matt

    2012-01-01

    Follow the creation of a multi-site instance with Drupal. The practical examples and accompanying screenshots will help you to get multiple Drupal sites set up in no time. This book is for Drupal site builders. It is assumed that readers are familiar with Drupal already, with a basic grasp of its concepts and components. System administration concepts, such as configuring Apache, MySQL, and Vagrant are covered but no previous knowledge of these tools is required.

  7. Friction modelling of preloaded tube contact dynamics

    International Nuclear Information System (INIS)

    Hassan, M.A.; Rogers, R.J.

    2005-01-01

    Many loosely supported components are subjected to flow-induced vibration leading to localized wear. Life prediction depends on robust and accurate modelling of the nonlinear dynamics as the components interact with their supports. The output of such analysis is the component dynamic response and impact forces, including friction forces during stick-slip motions. Such results are used to determine the normal work rates, which are utilized to predict fretting wear damage. Accurate estimates of these parameters are essential. This paper presents simulations of a loosely supported fuel-channel tube subject to turbulence excitation. The effects of tube/support clearance and preload are investigated. Several friction models, including velocity-limited, spring-damper and force-balance are utilized. A comparison of these models is carried out to investigate their accuracy. The results show good agreement with experimental work rates when a simple iterative procedure to update the friction forces is used

  8. Transvaginal recanalization of the obstructed fallopian tube

    International Nuclear Information System (INIS)

    Platia, M.; Chang, R.; Doppman, J.L.; Malinosky, R.; Busse, M.

    1988-01-01

    Since the first report of successful transvaginal recanalization of the occluded fallopian tube, a protocol for evaluation of the technical feasibility of the procedure and its impact on infertility has been initiated. Patients are accepted only if bilateral fallopian tube obstruction has been demonstrated by prior hysterosalpingography and if laparoscopy has excluded other causes for infertility. Repeat hysterosalpingography, including use of intravenous glucagon (1 mg) when necessary is performed on initial evaluation. Of 26 patients referred for treatment of tubal obstruction, nine patients were found to have tubal patency, indicating the importance of careful reevaluation. The 17 remaining patients underwent the transvaginal recanalization procedure. The technical success of the procedure is high (88%), particularly with use of either the system developed by Thurmond et al or a system with slightly modified catheters. Two pregnancies, one ectopic and one intrauterine, occurred in the same ovulatory cycle of the recanalization procedure

  9. Friction modelling of preloaded tube contact dynamics

    International Nuclear Information System (INIS)

    Hassan, M.A.; Rogers, R.J.

    2004-01-01

    Many loosely supported components are subjected to flow-induced vibration leading to localized wear. Life prediction depends on robust and accurate modelling of the nonlinear dynamics as the components interact with their supports. The output of such analysis is the component dynamic response and impact forces, including friction forces during stick-slip motions. Such results are used to determine the normal work rates, which are utilized to predict fretting wear damage. Accurate estimates of these parameters are essential. This paper presents simulations of a loosely supported fuel-channel tube subject to turbulence excitation. The effects of tube/support clearance and preload are investigated. Several friction models, including velocity-limited, spring-damper, and force-balance are utilized. A comparison of these models is carried out to investigate their accuracy. The results show good agreement with experimental work rates when a simple iterative procedure to update the friction forces is used. (authors)

  10. Small-size streak tube for imaging lidar

    Science.gov (United States)

    Tian, Jinshou; Hui, Dandan; Luo, Duan; Wang, Tao; Zhang, Jun; Chen, Shaorong; Jia, Hui

    2017-02-01

    Streak tube imaging lidar, as a novel flash lidar, due to its advantages of higher resolution for low contrast conditions, compact and rugged physical configurations, small image distortions owing to its scannerless design, and higher image update rates, has immense potential to provide 3D single-laser-pulse scannerless imaging, 3D multispectral imaging, 3D multispectral fluorescence imaging, and 3D polarimetry. In order to further reduce the size and enlarge the field of view (FOV) of the lidar system, we designed a super small-size, large photocathode area and meshless streak tube with spherical cathode and screen. With the aid of Computer Simulation Technology Software package (CST), a model of the streak tube was built, and its predominant performances were illustrated via tracking electron trajectories. Spatial resolution of the streak tube reaches 20lp/mm over the entire ∅28mm photocathode working area, and its temporal resolution is better than 30ps. Most importantly, the external dimensions of the streak tube are only ∅50mmx100mm. And several prototypes are already manufactured on the basis of the computer design.

  11. Configuration Management Process Assessment Strategy

    Science.gov (United States)

    Henry, Thad

    2014-01-01

    Purpose: To propose a strategy for assessing the development and effectiveness of configuration management systems within Programs, Projects, and Design Activities performed by technical organizations and their supporting development contractors. Scope: Various entities CM Systems will be assessed dependent on Project Scope (DDT&E), Support Services and Acquisition Agreements. Approach: Model based structured against assessing organizations CM requirements including best practices maturity criteria. The model is tailored to the entity being assessed dependent on their CM system. The assessment approach provides objective feedback to Engineering and Project Management of the observed CM system maturity state versus the ideal state of the configuration management processes and outcomes(system). center dot Identifies strengths and risks versus audit gotcha's (findings/observations). center dot Used "recursively and iteratively" throughout program lifecycle at select points of need. (Typical assessments timing is Post PDR/Post CDR) center dot Ideal state criteria and maturity targets are reviewed with the assessed entity prior to an assessment (Tailoring) and is dependent on the assessed phase of the CM system. center dot Supports exit success criteria for Preliminary and Critical Design Reviews. center dot Gives a comprehensive CM system assessment which ultimately supports configuration verification activities.*

  12. Dynamic configuring of the metastructure

    Directory of Open Access Journals (Sweden)

    Katarzyna Grzybowska

    2012-06-01

    Full Text Available Background: A trend to create groups of enterprises can be observed; whose model of operation makes use of assets of large, small and medium sized companies. It is a higher level of organisational changes. This trend is described as network organisation. It is based on the so called supply chain. The Authors of this paper proposed authors' analysis dynamic configuration of the supply chain and presents an example. The supply chain is a metastructure. It is an intermediate form between a single enterprise (microstructure/microsystem and the global economy (macrostructure/macrosystem. The metastructure is characterized by a dynamic holarchy of mutually cooperating holons (enterprises. Methods: After a brief discussion of the nature of supply chain (metrastructure and configuration of metastructures, authors present variable supply chains in the light of morphological analysis and presents an example.   Results: The key benefits of this approach are: identifying the characteristics of a supply network and modeling the flow in the entire own supply chain metastructure and possible quick adaptations to new situations. Conclusions: Configuration of a supply chain with the use of a morphological analysis is a basic action, if its goal is to optimally model the flow of goods and implementation of quick adaptation to new situations.     

  13. New Classes of Quasi-Axisymmetric Configurations

    International Nuclear Information System (INIS)

    Ku, L. P.; Garabedian, P. R.

    2005-01-01

    -stationary. The predicted MHD stability limits based on linear theories were surpassed. A beta of 3.5% was achieved in W7AS [3] and 4% in LHD [4], limited only by the available heating power and perhaps the integrity of the equilibrium flux surfaces. These results led us to focus particularly in three areas: minimizing the loss of ? particles in a reactor, developing very compact devices and finding novel ways to assure integrity of flux surfaces at high ?. It is known that the confinement of energetic particles in a QAS is sensitive to the ripple structure along magnetic field lines due to the long connection lengths. In a DT reactor, good confinement of ? particles is of particular importance because of its role in the power balance and because of the potential impact on the local heating and damage to the first wall if they escape. While very low residues in the magnetic spectrum constitute a sufficient condition for good confinement, other constraints such as the local shear required for MHD stability may make the attainment of negligibly small residues impractical. We have found that by introducing a designer's principle mirror component in the magnetic spectrum of the magnitude equal 1-2%, a QA configuration may be made much less susceptible to the loss of energetic particles and its ripple characteristics much improved. This leads to a new family of configurations similar in physics properties to those of NCSX but with significantly better particle orbits. Section II presents a typical example. (Author)

  14. Characterization of tube support alloys

    International Nuclear Information System (INIS)

    Vaia, A.R.

    1985-01-01

    The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions

  15. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  16. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia NEI Home Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  17. 27 CFR 40.352 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 40.352... OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Manufacture of Cigarette Papers and Tubes Taxes § 40.352 Cigarette tubes. Cigarette tubes...

  18. Modelling of the ultrasonic inspection of steel tubes with longitudinal defects; Modelisation du controle ultrasonore de tubes d`acier presentant des defauts de type ``entaille longitudinale``

    Energy Technology Data Exchange (ETDEWEB)

    Mephane, M

    1998-12-31

    A model has been developed in order to simulate the ultrasonic inspection of steel tubes in the Vallourec control configuration. The model permits to simulate the control of steel tubes showing longitudinal defects located near the internal or external surface of tubes which appear during the rolling process. To detect this kind of defect, the probe is placed in an incident place perpendicular to the tube`s axis. The probe is in front of the external surface of the tube. The main characteristics of the model is to assume that the field radiated in the material does not depend on the probe`s position. This assumption permits to treat separately the field retracted in the material and the interaction between the defect and the ultrasonic beam. The focal plane is located in the material, so the plane waves approximation is applied where the waves front are assumed plane and parallel. The parallel refracted beam becomes divergent after reflection on the internal surface of tube. To treat the beam divergence, an amplitude weighting coefficient is then calculated by mean of the energy conservation of a tube of rays before and after reflection, following the Snell laws. This model can predict the edge diffraction echoes, the echoes issued from the corner effect, and also the mode conversion echoes. It has been validated on artificial notches, and on some natural defects. A comparison between experimental and modelling results shows a good agreement. (author) 39 refs.

  19. Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test.

    Science.gov (United States)

    Gilbert, Hunter B; Hendrick, Richard J; Webster, Robert J

    2016-02-01

    Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for how stable a given robot configuration is has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e. whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.

  20. A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Herer, C. [RRAMATOME EP/TC, Paris (France); Souyri, A. [EdF DER/RNE/TTA, Chatou (France); Garnier, J. [CEA DRN/DTP/STR/LETC, Grenoble (France)

    1995-09-01

    Critical Heat Flux (CHF) tests were carried out in three tubes with inside diameters of 8, 13, and 19.2 mm and in two annuli with an inner tube of 9.5 mm and an outer tube of 13 or 19.2 mm. All axial heat flux distributions in the test sections were uniform. The coolant fluid was Refrigerant 12 (Freon-12) under PWR thermal-hydraulic conditions (equivalent water conditions - Pressure: 7 to 20 MPa, Mass Velocity: 1000 to 6000 kg/m2/s, Local Quality: -75% to +45%). The effect of tube diameter is correlated for qualities under 15%. The change from the tube to the annulus configuration is correctly taken into account by the equivalent hydraulic diameter. Useful information is also provided concerning the effect of a cold wall in an annulus.

  1. Configuration study of large wind parks

    Energy Technology Data Exchange (ETDEWEB)

    Lundberg, Stefan

    2003-07-01

    In this thesis, layouts of various large-scale wind parks, using both AC as well as DC, are investigated. Loss modelling of the wind park components as well as calculations of the energy capture of the turbines using various electrical systems are performed, and the energy production cost of the various park configurations is determined. The most interesting candidate for a DC transmission based wind park was investigated more in detail, the series DC wind park. Finally, the power quality impact in the PCC (point of common coupling) was studied. It was found that from an energy capture point of view, the difference in energy production between various wind turbine systems is very small. Of all the investigated wind park configurations, the wind park with the series connected DC wind turbines seems to have the best potential to give the lowest energy production cost, if the transmission distance is longer then 10-20 km. Regarding the series DC wind park it was found that it is the most difficult one to control. However, a control algorithm for the series park and its turbines was derived and successfully tested. Still, several more details regarding the control of the series wind park has to be dealt with.

  2. Initial DEMO tokamak design configuration studies

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Christian, E-mail: christian.bachmann@efda.org [EFDA, Boltzmannstraße 2, 85748 Garching (Germany); Aiello, G. [CEA-Saclay, DEN, DM2S, SEMT, F-91191 Gif-Sur-Yvette (France); Albanese, R.; Ambrosino, R. [ENEA/CREATE, Universita di Napoli Federico II, Naples (Italy); Arbeiter, F. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Aubert, J. [CEA-Saclay, DEN, DM2S, SEMT, F-91191 Gif-Sur-Yvette (France); Boccaccini, L.; Carloni, D. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Federici, G. [EFDA, Boltzmannstraße 2, 85748 Garching (Germany); Fischer, U. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Kovari, M. [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Li Puma, A. [CEA-Saclay, DEN, DM2S, SEMT, F-91191 Gif-Sur-Yvette (France); Loving, A. [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Maione, I. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Mattei, M. [ENEA/CREATE, Universita di Napoli Federico II, Naples (Italy); Mazzone, G. [ENEA C.R. Frascati, via E. Fermi 45, 00044 Frascati, Roma (Italy); Meszaros, B. [EFDA, Boltzmannstraße 2, 85748 Garching (Germany); Palermo, I. [Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Pereslavtsev, P. [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany); Riccardo, V. [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); and others

    2015-10-15

    Highlights: • A definition of main DEMO requirements. • A description of the DEMO tokamak design configuration. • A description of issues yet to be solved. - Abstract: To prepare the DEMO conceptual design phase a number of physics and engineering assessments were carried out in recent years in the frame of EFDA concluding in an initial design configuration of a DEMO tokamak. This paper gives an insight into the identified engineering requirements and constraints and describes their impact on the selection of the technologies and design principles of the main tokamak components. The EU DEMO program aims at making best use of the technologies developed for ITER (e.g., magnets, vessel, cryostat, and to some degree also the divertor). However, other systems in particular the breeding blanket require design solutions and advanced technologies that will only partially be tested in ITER. The main differences from ITER include the requirement to breed, to extract, to process and to recycle the tritium needed for plasma operation, the two orders of magnitude larger lifetime neutron fluence, the consequent radiation dose levels, which limit remote maintenance options, and the requirement to use low-activation steel for in-vessel components that also must operate at high temperature for efficient energy conversion.

  3. Pulsed Drift Tube Accelerator

    International Nuclear Information System (INIS)

    Faltens, A.

    2004-01-01

    The pulsed drift-tube accelerator (DTA) concept was revived by Joe Kwan and John Staples and is being considered for the HEDP/WDM application. It could be used to reach the full energy or as an intermediate accelerator between the diode and a high gradient accelerator such as multi-beam r.f. In the earliest LBNL HIF proposals and conceptual drivers it was used as an extended injector to reach energies where an induction linac with magnetic quadrupoles is the best choice. For HEDP, because of the very short pulse duration, the DTA could provide an acceleration rate of about 1MV/m. This note is divided into two parts: the first, a design based on existing experience; the second, an optimistic extrapolation. The first accelerates 16 parallel K + beams at a constant line charge density of 0.25(micro) C/m per beam to 10 MeV; the second uses a stripper and charge selector at around 4MeV followed by further acceleration to reach 40 MeV. Both benefit from more compact sources than the present 2MV injector source, although that beam is the basis of the first design and is a viable option. A pulsed drift-tube accelerator was the first major HIF experiment at LBNL. It was designed to produce a 2(micro)s rectangular 1 Ampere C s + beam at 2MeV. It ran comfortably at 1.6MeV for several years, then at lower voltages and currents for other experiments, and remnants of that experiment are in use in present experiments, still running 25 years later. The 1A current, completely equivalent to 1.8A K + , was chosen to be intermediate between the beamlets appropriate for a multi-beam accelerator, and a single beam of, say, 10A, at injection energies. The original driver scenarios using one large beam on each side of the reactor rapidly fell out of favor because of the very high transverse and longitudinal fields from the beam space charge, circa 1MV/cm and 250 kV/cm respectively, near the chamber and because of aberrations in focusing a large diameter beam down to a 1mm radius spot at a

  4. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  5. Conditioning and breakdown phenomena in accelerator tubes

    International Nuclear Information System (INIS)

    Skorka, S.J.

    1979-01-01

    Important breakdown mechanisms in accelerator tubes are reviewed, and discharge phenomena in NEC tubes are deduced from the surface appearance of the electrodes and insulators of a used tube. Microphotos of these surfaces are shown

  6. Eddy current signal comparison for tube identification

    Science.gov (United States)

    Glass, S. W.; Vojvodic, R.

    2015-03-01

    Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been some instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.

  7. Dimensional regularization in configuration space

    International Nuclear Information System (INIS)

    Bollini, C.G.; Giambiagi, J.J.

    1995-09-01

    Dimensional regularization is introduced in configuration space by Fourier transforming in D-dimensions the perturbative momentum space Green functions. For this transformation, Bochner theorem is used, no extra parameters, such as those of Feynman or Bogoliubov-Shirkov are needed for convolutions. The regularized causal functions in x-space have ν-dependent moderated singularities at the origin. They can be multiplied together and Fourier transformed (Bochner) without divergence problems. The usual ultraviolet divergences appear as poles of the resultant functions of ν. Several example are discussed. (author). 9 refs

  8. Stopped nucleons in configuration space

    Energy Technology Data Exchange (ETDEWEB)

    Bialas, Andrzej [Jagellonian Univ., Krakow (Poland); Bzdak, Adam [AGH - Univ. of Science and Technology, Krakow (Poland); Koch, Volker [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-09

    In this note, using the colour string model, we study the configuration space distribution of stopped nucleons in heavy-ion collisions. We find that the stopped nucleons from the target and the projectile end up separated from each other by the distance increasing with the collision energy. In consequence, for the center of mass energies larger than 6 or 10 GeV (depending on the details of the model) it appears that the system created is not in thermal and chemical equilibrium, and the net baryon density reached is likely not much higher than that already present in the colliding nuclei.

  9. FED pumped limiter configuration issues

    International Nuclear Information System (INIS)

    Haines, J.R.; Fuller, G.M.

    1983-01-01

    Impurity control in the Fusion Engineering Device (FED) is provided by a toroidal belt pumped limiter. Limiter design issues addressed in this paper are (1) poloidal location of the limiter belt, (2) shape of the limiter surface facing the plasma, and (3) whether the belt is pumped from one or both sides. The criteria used for evaluation of limiter configuration features were sensitivity to plasma edge conditions and ease of maintenance and fabrication. The evaluation resulted in the selection of a baseline FED limiter that is located at the bottom of the device and has a flat surface with a single leading edge

  10. Stresses in equilibrium configurations of inextensible nets with slack

    Czech Academy of Sciences Publication Activity Database

    Šilhavý, Miroslav

    2017-01-01

    Roč. 22, č. 4 (2017), s. 649-665 ISSN 1081-2865 Institutional support: RVO:67985840 Keywords : three-dimensional space * stresses in equilibrium configurations Subject RIV: BA - General Mathematics OBOR OECD: Applied mathematics Impact factor: 2.953, year: 2016 http://journals.sagepub.com/doi/full/10.1177/1081286515599597

  11. Fluidic valves for variable-configuration gas treatment

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2005-01-01

    Roč. 83, A9 (2005), s. 1111-1121 ISSN 0263-8762 Institutional research plan: CEZ:AV0Z20760514 Keywords : fluidics valves * vehicle emissions * variable configuration Subject RIV: BK - Fluid Dynamics Impact factor: 0.792, year: 2005

  12. mouseTube

    Science.gov (United States)

    Torquet, Nicolas; de Chaumont, Fabrice; Faure, Philippe; Bourgeron, Thomas; Ey, Elodie

    2016-01-01

    Ultrasonic vocalisation is a broadly used proxy to evaluate social communication in mouse models of neuropsychiatric disorders. The efficacy and robustness of testing these models suffer from limited knowledge of the structure and functions of these vocalisations as well as of the way to analyse the data. We created mouseTube , an open database with a web interface, to facilitate sharing and comparison of ultrasonic vocalisations data and metadata attached to a recording file. Metadata describe 1) the acquisition procedure, e.g ., hardware, software, sampling frequency, bit depth; 2) the biological protocol used to elicit ultrasonic vocalisations; 3) the characteristics of the individual emitting ultrasonic vocalisations ( e.g. , strain, sex, age). To promote open science and enable reproducibility, data are made freely available. The website provides searching functions to facilitate the retrieval of recording files of interest. It is designed to enable comparisons of ultrasonic vocalisation emission between strains, protocols or laboratories, as well as to test different analysis algorithms and to search for protocols established to elicit mouse ultrasonic vocalisations. Over the long term, users will be able to download and compare different analysis results for each data file. Such application will boost the knowledge on mouse ultrasonic communication and stimulate sharing and comparison of automatic analysis methods to refine phenotyping techniques in mouse models of neuropsychiatric disorders.

  13. X-ray tube

    International Nuclear Information System (INIS)

    Mayo, B.J.

    1980-01-01

    An x-ray tube in which the x-ray origin is scanned on a circle around the patient, comprises a ring-shaped anode, an electron beam travelling along a circular path being deflected onto the anode at the desired positions. The electron beam path may be in a plane parallel to the anode and perhaps at the same radius. It may be in the same plane as a transmission target/anode and at a greater radius. The anode should extend over at least 180 0 although it may extend to 360 0 . Electrostatic means may be provided to constrain the beam to the circular path and further electrostatic means deflect it to the anode of the beam and ensure it is focused at the point of incidence. Collimators provide a planar fan-shaped beam and the anode may be shaped to attenuate side lobes of the radiation. Electrode collects electrons not deflected. The focal regions may be adjacent or otherwise. Coils may provide periodic focusing to overcome space charge dispersion and dynamic adjustment of the focusing before deflection ensures focusing at target incidence. Focusing may be absent near the deflection region, and current in the coil section near the focal region should be zero. (author)

  14. Example of software configuration management model

    International Nuclear Information System (INIS)

    Roth, P.

    2006-01-01

    Software configuration management is the mechanism used to track and control software changes and may include the following actions: A tracking system should be established for any changes made to the existing software configuration. Requirement of the configuration management system are the following: - Backup the different software configuration; - Record the details (the date, the subject, the filenames, the supporting documents, the tests, ...) of the changes introduced in the new configuration; - Document all the differences between the different versions. Configuration management allows simultaneous exploitation of one specific version and development of the next version. Minor correction can be perform in the current exploitation version

  15. Flux tubes at finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Cea, Paolo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Dipartimento di Fisica dell’Università di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cosmai, Leonardo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cuteri, Francesca; Papa, Alessandro [Dipartimento di Fisica, Università della Calabria & INFN-Cosenza,Ponte Bucci, cubo 31C, I-87036 Rende (Cosenza) (Italy)

    2016-06-07

    The chromoelectric field generated by a static quark-antiquark pair, with its peculiar tube-like shape, can be nicely described, at zero temperature, within the dual superconductor scenario for the QCD confining vacuum. In this work we investigate, by lattice Monte Carlo simulations of the SU(3) pure gauge theory, the fate of chromoelectric flux tubes across the deconfinement transition. We find that, if the distance between the static sources is kept fixed at about 0.76 fm ≃1.6/√σ and the temperature is increased towards and above the deconfinement temperature T{sub c}, the amplitude of the field inside the flux tube gets smaller, while the shape of the flux tube does not vary appreciably across deconfinement. This scenario with flux-tube “evaporation” above T{sub c} has no correspondence in ordinary (type-II) superconductivity, where instead the transition to the phase with normal conductivity is characterized by a divergent fattening of flux tubes as the transition temperature is approached from below. We present also some evidence about the existence of flux-tube structures in the magnetic sector of the theory in the deconfined phase.

  16. Multi-Canister overpack sealing configuration

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The Spent Nuclear Fuel (SNF) position regarding the Multi-Canister Overpack (MCO) sealing configuration is to initially rely on an American Society of Mechanical Engineers (ASME) Section III Subsection NB code compliant mechanical closure/sealing system to quickly and safely establish and maintain full confinement of radioactive materials prior to and during MCO fuel drying activities. Previous studies have shown the mechanical seal to be the preferred closure method, based on dose, cost, and schedule considerations. The cost and schedule impacts of redesigning the mechanical closure to a welded shield plug do not support changing the closure system. The SNF Project has determined that the combined mechanical/welded closure system meets or exceeds the regulatory requirements to provide redundant seals while accommodating key safety and schedule limitations that are unique to K Basins fuel removal effort

  17. Do China and oil exporters influence major currency configurations?

    OpenAIRE

    Fratzscher, Marcel; Mehl, Arnaud

    2008-01-01

    This paper analyses the impact of the shift away from a US dollar focus of systemically important emerging market economies (EMEs) on configurations between the US dollar, the euro and the yen. Given the difficulty that fixed or managed US dollar exchange rate regimes remain pervasive and reserve compositions mostly kept secret, the identification strategy of the paper is to analyse the market impact on major currency pairs of official statements made by EME policy-makers about their exchange...

  18. PEG tubes: dealing with complications.

    Science.gov (United States)

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  19. Rigid inflatable gastrostomy tube malposition

    Directory of Open Access Journals (Sweden)

    Timothy E. Murray, MB, MCh, MRCS, FFR

    2017-12-01

    Full Text Available Rigid inflatable gastrostomy (RIG tubes are widely used in contemporary clinical practice for a variety of indications. Insertion of RIG tubes is associated with a high technical success rate and low incidence of mortality. In this case report, a procedural pitfall associated with intraperitoneal-extragastric malposition is described. Rigorous assessment of abdominal radiographs, as well as awareness of the expected appearance of the RIG tube and gastropexy T-fasteners, allows the abdominal radiologist to detect early RIG position in the early postprocedural period. Abdominal radiography is a widely available and inexpensive technique. The high spatial resolution it provides makes it a valuable tool in determining hardware position.

  20. Expansion tube test time predictions

    Science.gov (United States)

    Gourlay, Christopher M.

    1988-01-01

    The interaction of an interface between two gases and strong expansion is investigated and the effect on flow in an expansion tube is examined. Two mechanisms for the unsteady Pitot-pressure fluctuations found in the test section of an expansion tube are proposed. The first mechanism depends on the Rayleigh-Taylor instability of the driver-test gas interface in the presence of a strong expansion. The second mechanism depends on the reflection of the strong expansion from the interface. Predictions compare favorably with experimental results. The theory is expected to be independent of the absolute values of the initial expansion tube filling pressures.

  1. Nasogastric feeding tubes from a neonatal department yield high concentrations of potentially pathogenic bacteria- even 1 d after insertion

    DEFF Research Database (Denmark)

    Meinich Petersen, Sandra; Greisen, Gorm; Krogfelt, Karen Angeliki

    2016-01-01

    BACKGROUND: Preterm infants are vulnerable to pathogens and at risk of developing necrotizing enterocolitis (NEC) or sepsis. Nasogastric feeding tubes (NG-tubes) might contaminate feeds given through them due to biofilm formation. We wanted to determine if there is a rationale in replacing NG...... to determine if changing the NG-tubes between meals or once a day will make a positive impact on tube contamination and clinical parameters....

  2. Tank waste remediation system configuration management plan

    International Nuclear Information System (INIS)

    Vann, J.M.

    1998-01-01

    The configuration management program for the Tank Waste Remediation System (TWRS) Project Mission supports management of the project baseline by providing the mechanisms to identify, document, and control the functional and physical characteristics of the products. This document is one of the tools used to develop and control the mission and work. It is an integrated approach for control of technical, cost, schedule, and administrative information necessary to manage the configurations for the TWRS Project Mission. Configuration management focuses on five principal activities: configuration management system management, configuration identification, configuration status accounting, change control, and configuration management assessments. TWRS Project personnel must execute work in a controlled fashion. Work must be performed by verbatim use of authorized and released technical information and documentation. Application of configuration management will be consistently applied across all TWRS Project activities and assessed accordingly. The Project Hanford Management Contract (PHMC) configuration management requirements are prescribed in HNF-MP-013, Configuration Management Plan (FDH 1997a). This TWRS Configuration Management Plan (CMP) implements those requirements and supersedes the Tank Waste Remediation System Configuration Management Program Plan described in Vann, 1996. HNF-SD-WM-CM-014, Tank Waste Remediation System Configuration Management Implementation Plan (Vann, 1997) will be revised to implement the requirements of this plan. This plan provides the responsibilities, actions and tools necessary to implement the requirements as defined in the above referenced documents

  3. Computational methods for stellerator configurations

    International Nuclear Information System (INIS)

    Betancourt, O.

    1992-01-01

    This project had two main objectives. The first one was to continue to develop computational methods for the study of three dimensional magnetic confinement configurations. The second one was to collaborate and interact with researchers in the field who can use these techniques to study and design fusion experiments. The first objective has been achieved with the development of the spectral code BETAS and the formulation of a new variational approach for the study of magnetic island formation in a self consistent fashion. The code can compute the correct island width corresponding to the saturated island, a result shown by comparing the computed island with the results of unstable tearing modes in Tokamaks and with experimental results in the IMS Stellarator. In addition to studying three dimensional nonlinear effects in Tokamaks configurations, these self consistent computed island equilibria will be used to study transport effects due to magnetic island formation and to nonlinearly bifurcated equilibria. The second objective was achieved through direct collaboration with Steve Hirshman at Oak Ridge, D. Anderson and R. Talmage at Wisconsin as well as through participation in the Sherwood and APS meetings

  4. Hanford Environmental Information System Configuration Management Plan

    International Nuclear Information System (INIS)

    1996-06-01

    The Hanford Environmental Information System (HEIS) Configuration Management Plan establishes the software and data configuration control requirements for the HEIS and project-related databases maintained within the Environmental Restoration Contractor's data management department

  5. Configurations and level structure of 219Rn

    International Nuclear Information System (INIS)

    Sheline, R.K.; Liang, C.F.; Paris, P.

    1998-01-01

    The level structure of 219 Rn has been studied using the alpha decay of 223 Ra and coincident gamma rays. While only modest changes are required in the level structure, and only above 342.8 keV, severe changes are required throughout the level scheme in the spin assigments. These changes allow the assignment of two sets of anomalous bands with K=5/2 ± and K=3/2 ± . The K=5/2 ± bands have configurations intermediate between the reflection asymmetric configuration and the g 9/2 shell model configuration, while the K=3/2 ± bands have configurations intermediate between the mixed reflection asymmetric configuration and the i 11/2 shell model configuration. Comparison of the systematics of 219 Rn with neighboring isotones, isobars, and isotopes shows clearly the collapse of the quadrupole-octupole-type configurations into the less degenerate shell model configurations. copyright 1998 The American Physical Society

  6. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  7. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  8. Tube-wave seismic imaging

    Science.gov (United States)

    Korneev, Valeri A [LaFayette, CA

    2009-05-05

    The detailed analysis of cross well seismic data for a gas reservoir in Texas revealed two newly detected seismic wave effects, recorded approximately 2000 feet above the reservoir. A tube-wave (150) is initiated in a source well (110) by a source (111), travels in the source well (110), is coupled to a geological feature (140), propagates (151) through the geological feature (140), is coupled back to a tube-wave (152) at a receiver well (120), and is and received by receiver(s) (121) in either the same (110) or a different receiving well (120). The tube-wave has been shown to be extremely sensitive to changes in reservoir characteristics. Tube-waves appear to couple most effectively to reservoirs where the well casing is perforated, allowing direct fluid contact from the interior of a well case to the reservoir.

  9. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > ...

  10. Lunar Core Drive Tubes Summary

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains a brief summary and high resolution imagery from various lunar rock and core drive tubes collected from the Apollo and Luna missions to the moon.

  11. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video ...

  12. Conditioning of NEC accelerator tubes

    International Nuclear Information System (INIS)

    Yntema, J.L.

    1979-01-01

    The conditioning process of NEC tubes was investigated by recording the fluctuations observed with a residual gas analyzer for a fixed mass and a simultaneous recording of the current fluctuations in background pressure

  13. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino ... To search for current job openings visit HHS USAJobs Home » NEI YouTube ...

  14. Eddy current tube testing unit

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Duret, G.

    1975-01-01

    The unit described can check a wide variety of tubes in quick succession and its modular design gives it a high degree of versability. Suitably defined working conditions and specific fittings enable most of the faults encountered in the manufacture of a tube to be detected. By appropriate means of selection based on signal amplitude, phase and frequency analyses it is possible to adapt selection criteria to the seriousness of the different categories of defect [fr

  15. Electronics for proportional drift tubes

    International Nuclear Information System (INIS)

    Fremont, G.; Friend, B.; Mess, K.H.; Schmidt-Parzefall, W.; Tarle, J.C.; Verweij, H.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Geske, K.; Riege, H.; Schuett, J.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Semenov, Y.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration)

    1980-01-01

    An electronic system for the read-out of a large number of proportional drift tubes (16,000) has been designed. This system measures deposited charge and drift-time of the charge of a particle traversing a proportional drift tube. A second event can be accepted during the read-out of the system. Up to 40 typical events can be collected and buffered before a data transfer to a computer is necessary. (orig.)

  16. The YouTube reader

    OpenAIRE

    Snickars, Pelle; Vonderau, Patrick

    2009-01-01

    YouTube has come to epitomize the possibilities of digital culture. With more than seventy million unique users a month and approximately eighty million videos online, this brand-name video distribution platform holds the richest repository of popular culture on the Internet. As the fastest growing site in the history of the Web, YouTube promises endless new opportunities for amateur video, political campaigning, entertainment formats, and viral marketing—a clip culture that has seemed to out...

  17. Offshore Vendors’ Software Development Team Configurations

    DEFF Research Database (Denmark)

    Chakraborty, Suranjan; Sarker, Saonee; Rai, Sudhanshu

    2012-01-01

    This research uses configuration theory and data collected from a major IT vendor organization to examine primary configurations of distributed teams in a global off-shoring context. The study indicates that off-shoring vendor organizations typically deploy three different types of configurations...

  18. Offshore Vendors' Software Development Team Configuration

    DEFF Research Database (Denmark)

    Chakraborty, Suranjan; Sarker, Saonee; Rai, Sudhanshu

    2011-01-01

    This research uses configuration theory and data collected from a major IT vendor organization to examine primary configurations of distributed teams in a global off-shoring context. The study indicates that off-shoring vendor organizations typically deploy three different types of configurations...

  19. Multi level configuration of ETO products

    DEFF Research Database (Denmark)

    Petersen, Thomas Ditlev; Jørgensen, Kaj Asbjørn; Hvolby, Hans-Henrik

    2007-01-01

    The paper introduces and defines central concepts related to multi level configuration and analyzes which challenges an engineer to order company must deal with to be able to realize a multi level configuration system. It is argued that high flexibility can be achieved and focus can be directed...... in certain business processes if a multi level configuration system is realized....

  20. Numerical simulation of flow-induced vibrations in tube bundles

    International Nuclear Information System (INIS)

    Elisabeth Longatte; Zaky Bendjeddou; Mhamed Souli

    2005-01-01

    Full text of publication follows: In many industrial components mechanical structures like rod cluster control assembly, fuel assembly and heat exchanger tube bundles are submitted to complex flows causing possible vibrations and damage. Fluid forces are usually split into two parts: structure motion independent forces and fluid-elastic forces coupled with tube motion and responsible for possible dynamic instability development leading to possible short term failures through high amplitude vibrations. Most classical fluid force identification methods rely on structure response experimental measurements associated with convenient data processes. Owing to recent improvements in Computational Fluid Dynamics (C.F.D.), numerical fluid force identification is now practicable in the presence of industrial configurations. The present paper is devoted to numerical simulation of flow-induced vibrations of tube bundles submitted to single-phase cross flows by using C.F.D. codes. Direct Numerical Simulation (D.N.S.), Arbitrary Lagrange Euler formulation (A.L.E.) and code coupling process are involved to predict fluid forces responsible for tube bundle vibrations in the presence of fluid structure and fluid-elastic coupling effects. In the presence of strong multi-physics coupling, simulation of flow-induced vibrations requires a fluid structure code coupling process. The methodology consists in solving in the same time thermohydraulics and mechanics problems by using an A.L.E. formulation for the fluid computation. The purpose is to take into account coupling between flow and structure motions in order to be able to capture coupling effects. From a numerical point of view, there are three steps in the computation: the fluid problem is solved on the computational domain; fluid forces acting on the moving tube are estimated; finally they are introduced in the structure solver providing the tube displacement that is used to actualize the fluid computational domain. Specific

  1. Studying the heat transfer in chess-type bundles of smooth and ribbed tubes in boiling layers

    International Nuclear Information System (INIS)

    Zhitomirskaya, I.V.; Migaj, V.K.; Rassudov, N.S.; Shemyakin, V.N.

    1982-01-01

    Heat transfer between horizontal bundles of steel smooth and ribbed tubes and fluidized bed of large-dispersed packing of balls from 2.8 upto 4 mm in diameter is investigated. The heat transfer has been investigated by stationary methods by means of alpha calorimeters representing parts of the investigated tubes with electric heaters mounted inside them. The results obtained show that the heat removal per carrying tube surface increases by 1.92 times at the ribbing coefficient equal to 3.6. This testifies to the decrease in heat transfer coefficient per total surface of the tube. The conclusion is drawn on the efficiency of ribbed tube application in small size heat exchangers and necessity of further investigations in the direction of search for optimal configuration of tube bundles with a developed external surface

  2. Dermatology on YouTube.

    Science.gov (United States)

    Boyers, Lindsay N; Quest, Tyler; Karimkhani, Chante; Connett, Jessica; Dellavalle, Robert P

    2014-06-15

    YouTube, reaches upwards of six billion users on a monthly basis and is a unique source of information distribution and communication. Although the influence of YouTube on personal health decision-making is well established, this study assessed the type of content and viewership on a broad scope of dermatology related content on YouTube. Select terms (i.e. dermatology, sun protection, skin cancer, skin cancer awareness, and skin conditions) were searched on YouTube. Overall, the results included 100 videos with over 47 million viewers. Advocacy was the most prevalent content type at 24% of the total search results. These 100 videos were "shared" a total of 101,173 times and have driven 6,325 subscriptions to distinct YouTube user pages. Of the total videos, 35% were uploaded by or featured an MD/DO/PhD in dermatology or other specialty/field, 2% FNP/PA, 1% RN, and 62% other. As one of the most trafficked global sites on the Internet, YouTube is a valuable resource for dermatologists, physicians in other specialties, and the general public to share their dermatology-related content and gain subscribers. However, challenges of accessing and determining evidence-based data remain an issue.

  3. Code organization and configuration management

    International Nuclear Information System (INIS)

    Wellisch, J.P.; Ashby, S.; Williams, C.; Osborne, I.

    2001-01-01

    Industry experts are increasingly focusing on team productivity as the key to success. The base of the team effort is the four-fold structure of software in terms of logical organisation, physical organisation, managerial organisation, and dynamical structure. The authors describe the ideas put into action within the CMS software for organising software into sub-systems and packages, and to establish configuration management in a multi-project environment. The authors use a structure that allows to maximise the independence of software development in individual areas, and at the same time emphasises the overwhelming importance of the interdependencies between the packages and components in the system. The authors comment on release procedures, and describe the inter-relationship between release, development, integration, and testing

  4. Pre and post garter spring repositioning ultrasonic inspection of pressure tubes

    International Nuclear Information System (INIS)

    Desimone, C.; Katchadjian, P.; Tacchia, Mauricio

    1997-01-01

    This paper present a description of the ultrasonic cracked hydride blister detections system used for pre and post inspection of pressure tubes during garter spring repositioning in CNE (Embalse Nuclear Power Station). Ultrasonic system setup configuration, transducers characteristics, blister detection head, calibration of parameters, operating procedure, records of ultrasonic inspections and evaluation. (author) [es

  5. Tagging of Test Tubes with Electronic p-Chips for Use in Biorepositories.

    Science.gov (United States)

    Mandecki, Wlodek; Kopacka, Wesley M; Qian, Ziye; Ertwine, Von; Gedzberg, Katie; Gruda, Maryann; Reinhardt, David; Rodriguez, Efrain

    2017-08-01

    A system has been developed to electronically tag and track test tubes used in biorepositories. The system is based on a light-activated microtransponder, also known as a "p-Chip." One of the pressing problems with storing and retrieving biological samples at low temperatures is the difficulty of reliably reading the identification (ID) number that links each storage tube with the database containing sample details. Commonly used barcodes are not always reliable at low temperatures because of poor adhesion of the label to the test tube and problems with reading under conditions of frost and ice accumulation. Traditional radio frequency identification (RFID) tags are not cost effective and are too large for this application. The system described herein consists of the p-Chip, p-Chip-tagged test tubes, two ID readers (for single tubes or for racks of tubes), and software. We also describe a robot that is configured for retrofitting legacy test tubes in biorepositories with p-Chips while maintaining the temperature of the sample below -50°C at all times. The main benefits of the p-Chip over other RFID devices are its small size (600 × 600 × 100 μm) that allows even very small tubes or vials to be tagged, low cost due to the chip's unitary construction, durability, and the ability to read the ID through frost and ice.

  6. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    International Nuclear Information System (INIS)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models

  7. Heat transfer in tube bundles of heat exchangers with flow baffles induced forced mixing

    International Nuclear Information System (INIS)

    AbuRomia, M.M.; Chu, A.W.; Cho, S.M.

    1976-01-01

    Thermal analysis of shell-and-tube heat exchangers is being investigated through geometric modeling of the unit configuration in addition to considering the heat transfer processes taking place within the tube bundle. The governing equations that characterize the heat transfer from the shell side fluid to the tube side fluid across the heat transfer tubewalls are indicated. The equations account for the heat transfer due to molecular conduction, turbulent thermal diffusion, and forced fluid mixing among various shell side fluid channels. The analysis, though general in principle, is being applied to the Clinch River Breeder Reactor Plant-Intermediate Heat Exchanger, which utilizes flow baffles appropriately designed for induced forced fluid mixing in the tube bundle. The results of the analysis are presented in terms of the fluid and tube wall temperature distributions of a non-baffled and baffled tube bundle geometry. The former case yields axial flow in the main bundle region while the latter is associated with axial/cross flow in the bundle. The radial components of the axial/cross flow yield the necessary fluid mixing that results in reducing the thermal unbalance among the heat transfer to the allowable limits. The effect of flow maldistribution, present on the tube or shell sides of the heat exchangers, in altering the temperature field of tube bundles is also noted

  8. Multi level configuration of ETO products

    DEFF Research Database (Denmark)

    Petersen, Thomas Ditlev; Jørgensen, Kaj Asbjørn; Hvolby, Hans-Henrik

    2007-01-01

    The paper introduces and defines central concepts related to multi level configuration and analyzes which challenges an engineer to order company must deal with to be able to realize a multi level configuration system. It is argued that high flexibility can be achieved and focus can be directed i...... in certain business processes if a multi level configuration system is realized.......The paper introduces and defines central concepts related to multi level configuration and analyzes which challenges an engineer to order company must deal with to be able to realize a multi level configuration system. It is argued that high flexibility can be achieved and focus can be directed...

  9. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impression tube. 872.6570 Section 872.6570 Food...

  10. 27 CFR 41.35 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 41.35... OF THE TREASURY (CONTINUED) TOBACCO IMPORTATION OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Taxes Tax Rates § 41.35 Cigarette tubes. Cigarette tubes are taxed at the following rates...

  11. Tubing vs. buckets: a cost comparison

    Science.gov (United States)

    Neil K. Huyler

    1975-01-01

    Equipment investment for tubing-vacuum systems was significantly less than that for bucket systems. Tubing-vacuum systems required about 22 percent less labor input, the major labor input being completed before sap-flow periods. Annual cost of operation was less for tubing-vacuum than the bucket system. Small tubing-vacuum operations showed more profit potential than...

  12. Aerodynamic configuration design using response surface methodology analysis

    Science.gov (United States)

    Engelund, Walter C.; Stanley, Douglas O.; Lepsch, Roger A.; Mcmillin, Mark M.; Unal, Resit

    1993-01-01

    An investigation has been conducted to determine a set of optimal design parameters for a single-stage-to-orbit reentry vehicle. Several configuration geometry parameters which had a large impact on the entry vehicle flying characteristics were selected as design variables: the fuselage fineness ratio, the nose to body length ratio, the nose camber value, the wing planform area scale factor, and the wing location. The optimal geometry parameter values were chosen using a response surface methodology (RSM) technique which allowed for a minimum dry weight configuration design that met a set of aerodynamic performance constraints on the landing speed, and on the subsonic, supersonic, and hypersonic trim and stability levels. The RSM technique utilized, specifically the central composite design method, is presented, along with the general vehicle conceptual design process. Results are presented for an optimized configuration along with several design trade cases.

  13. Supply chain configuration concepts, solutions, and applications

    CERN Document Server

    Chandra, Charu

    2016-01-01

    This book discusses the models and tools available for solving configuration problems, emphasizes the value of model integration to obtain comprehensive and robust configuration decisions, proposes solutions for supply chain configuration in the presence of stochastic and dynamic factors, and illustrates application of the techniques discussed in applied studies. It is divided into four parts, which are devoted to defining the supply chain configuration problem and identifying key issues, describing solutions to various problems identified, proposing technologies for enabling supply chain confirmations, and discussing applied supply chain configuration problems. Its distinguishing features are: an explicit focus on the configuration problem an in-depth coverage of configuration models an emphasis on model integration and application of information modeling techniques in decision-making New to this edition is Part II: Technologies, which introduces readers to various technologies being utilized for supply chai...

  14. Construction and characterization of a hollow cathode tube for high sensibility laser spectroscopy

    International Nuclear Information System (INIS)

    Morage, A.; Motta, C.C.

    1998-01-01

    A new hollow cathode tube argon-iron design was developed to be used in laser atomic spectroscopy experiments, were high sensibility is required. This tube was employed in order to allow laser absorption and optogalvanic signal measurements. The tube also included fused-quartz Brewster angle windows aligned with the optical axis in each ending of the tube. Therefore, in this configuration a minimum laser intensity losses through the windows can be attained for the appropriate light polarization. The optogalvanic signal detection was accomplished using a tunable dye laser resonant with the Ar, 3p 5 4p ( 3 S 1 )--> 3p 5 4d ( 3 D 1 0 ) transition, that corresponds to 591.2 nm in air. It was also possible to determine the gas temperature by measuring the Doppler line broadening and the results were compared to those obtained from a theoretical model for gas heat conduction. To measure the temperature of the cathode external surface a thermocouple was used inside the tube. The analysis of results showed that a high signal to noise ratio can be obtained with this tube configuration, that permits experimental investigation of electronic transitions presenting low light absorption cross sections. (author)

  15. Study on high throughput nanomanufacturing of photopatternable nanofibers using tube nozzle electrospinning with multi-tubes and multi-nozzles

    Science.gov (United States)

    Fang, Sheng-Po; Jao, PitFee; Senior, David E.; Kim, Kyoung-Tae; Yoon, Yong-Kyu

    2017-12-01

    High throughput nanomanufacturing of photopatternable nanofibers and subsequent photopatterning is reported. For the production of high density nanofibers, the tube nozzle electrospinning (TNE) process has been used, where an array of micronozzles on the sidewall of a plastic tube are used as spinnerets. By increasing the density of nozzles, the electric fields of adjacent nozzles confine the cone of electrospinning and give a higher density of nanofibers. With TNE, higher density nozzles are easily achievable compared to metallic nozzles, e.g. an inter-nozzle distance as small as 0.5 cm and an average semi-vertical repulsion angle of 12.28° for 8-nozzles were achieved. Nanofiber diameter distribution, mass throughput rate, and growth rate of nanofiber stacks in different operating conditions and with different numbers of nozzles, such as 2, 4 and 8 nozzles, and scalability with single and double tube configurations are discussed. Nanofibers made of SU-8, photopatternable epoxy, have been collected to a thickness of over 80 μm in 240 s of electrospinning and the production rate of 0.75 g/h is achieved using the 2 tube 8 nozzle systems, followed by photolithographic micropatterning. TNE is scalable to a large number of nozzles, and offers high throughput production, plug and play capability with standard electrospinning equipment, and little waste of polymer.

  16. Fluid simulations of edge turbulence for stellarators and axisymmetric configurations

    Science.gov (United States)

    Kleiber, R.; Scott, B.

    2005-10-01

    Nonlinear electromagnetic fluid simulations in a flux tube are used to compute the edge turbulence for a family of axisymmetric configurations with different rotational transform profiles (ι) and the stellarator Wendelstein 7-X (W7-X) [Grieger et al., Plasma Physics and Controlled Nuclear Fusion Research, 1990 (International Atomic Energy Agency, Vienna, 1991), Vol. 3, p. 525]. The influence of the ι profile on anomalous transport and the strength of zonal flows in these axisymmetric equilibria are studied and the results are connected to simulations for the W7-X equilibrium. A strong decrease in transport is found by increasing ι or switching the sign of the shear from tokamak-(ι'0). The effect of pressure-induced changes in the W7-X equilibrium geometry on the transport at fixed parameters is studied and a decrease in the transport following changes in the zonal flows is found.

  17. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    International Nuclear Information System (INIS)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R.

    2014-01-01

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators

  18. The Hardy inequality and the heat equation in twisted tubes

    Czech Academy of Sciences Publication Activity Database

    Krejčiřík, David; Zuazua, E.

    2010-01-01

    Roč. 94, č. 3 (2010), s. 277-303 ISSN 0021-7824 R&D Projects: GA MŠk LC06002 Institutional research plan: CEZ:AV0Z10480505 Keywords : Twisted tubes * Hardy inequality * Dirichlet Laplacian Subject RIV: BA - General Mathematics Impact factor: 1.450, year: 2010

  19. Spectral estimates for Dirichlet Laplacians on perturbed twisted tubes

    Czech Academy of Sciences Publication Activity Database

    Exner, Pavel; Barseghyan, Diana

    2014-01-01

    Roč. 8, č. 1 (2014), s. 167-183 ISSN 1846-3886 R&D Projects: GA ČR GAP203/11/0701 Institutional support: RVO:61389005 Keywords : Drichlet Laplacian * twisted tube * discrete spectrum * eigenvalue estimates Subject RIV: BE - Theoretical Physics Impact factor: 0.583, year: 2014

  20. Analysis of forming limit in tube hydroforming

    International Nuclear Information System (INIS)

    Kim, Chan Il; Yang, Seung Hang; Kim, Young Suk

    2013-01-01

    The automotive industry has shown increasing interest in tube hydroforming. Despite many automobile structural parts being produced from cylindrical tubes, failures frequently occur during tube hydroforming under improper forming conditions. These problems include wrinkling, buckling, folding back, and bursting. We perform analytical studies to determine forming limits in tube hydroforming and demonstrate how these forming limits are influenced by the loading path. Theoretical results for the forming limits of wrinkling and bursting are compared with experimental results for an aluminum tube.

  1. Maximum allowable heat flux for a submerged horizontal tube bundle

    International Nuclear Information System (INIS)

    McEligot, D.M.

    1995-01-01

    For application to industrial heating of large pools by immersed heat exchangers, the socalled maximum allowable (or open-quotes criticalclose quotes) heat flux is studied for unconfined tube bundles aligned horizontally in a pool without forced flow. In general, we are considering boiling after the pool reaches its saturation temperature rather than sub-cooled pool boiling which should occur during early stages of transient operation. A combination of literature review and simple approximate analysis has been used. To date our main conclusion is that estimates of q inch chf are highly uncertain for this configuration

  2. Physics of magnetic flux tubes

    CERN Document Server

    Ryutova, Margarita

    2015-01-01

    This book is the first account of the physics of magnetic flux tubes from their fundamental properties to collective phenomena in an ensembles of flux tubes. The physics of magnetic flux tubes is absolutely vital for understanding fundamental physical processes in the solar atmosphere shaped and governed by magnetic fields. High-resolution and high cadence observations from recent space and  ground-based instruments taken simultaneously at different heights and temperatures not only show the ubiquity of filamentary structure formation but also allow to study how various events are interconnected by system of magnetic flux tubes. The book covers both theory and observations. Theoretical models presented in analytical and phenomenological forms are tailored for practical applications. These are welded with state-of-the-art observations from early decisive ones to the most recent data that open a new phase-space for exploring the Sun and sun-like stars. Concept of magnetic flux tubes is central to various magn...

  3. Compact-immersed-tube bath heating for anodizing aluminum sections; Le chauffage de bains par tubes immerges compacts pour l`anodisation de profiles aluminium

    Energy Technology Data Exchange (ETDEWEB)

    Bouillet, B. [Societe Alusuisse (France); Lhomme, P.J. [Gaz de France (GDF), 75 - Paris (France)

    1996-12-31

    The compact-immersed-tube system is composed of a burner, a combustor (where natural gas is burned) and a heat exchanger tube (where combustion heat is released to the surrounding bath); its compact configuration is designed for a direct implementation in an industrial process vessel. Natural gas is thus directly used at the utilization location, without any vapour stage and distribution heat losses. Temperature regulation, efficiency, corrosion issues and power requirements are discussed. An application example with the bath heating for aluminum anodization, is presented: energy savings and payback periods are discussed

  4. Simulations numériques et validation expérimentale du comportement dynamique d'un tube

    OpenAIRE

    Benmalek, Wissam

    2014-01-01

    In steam generators, the primary loop tubes are subjected to fluid-elastic couplingforces and impacts. Understanding the dynamic of these tubes is crucial when designingsteam generators. Mastering coupling and impacts forces would allow engineers toimprove the design of structure components and would optimize the tube lifetime, whileimproving the overall performances of power plant.The aim of the current research is to provide a hybrid test technique reproducingthe modal coupling forces on a ...

  5. Environmental restoration project configuration control

    International Nuclear Information System (INIS)

    Hutterman, L.L.

    1991-01-01

    Projecting budget requirements for performing environmental restoration activities in a manner consistent with the regulatory agencies requires long-term planning, scheduling, and budget forecasting. The Westinghouse Idaho Nuclear Company, Inc. (WINCO) Environmental Restoration Program is responsible for 14 operable units at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). To facilitate response to US Department of Energy (DOE) requirements, a baseline document has been established, and activities for each of the environmental release sites have been developed. The baseline document is based primarily on the activities identified in the Interagency Agreement (IAG) for operable unit scoping and investigation. In addition, the schedule for some sites reflects fiscal year 1991 Consent Order Compliance Agreement requirements. Planning has been conducted through completion of the Record of Decision. The baseline document provides management with a defensible basis to project and control costs. Work that requires modification in scope, changes to applicable DOE or regulatory orders/guidance, or identification of additional release sites will normally impact costs and schedule. The impact of these changes will be evaluated and the baseline revised to reflect the changes. Management can use the baseline to evaluate potential cost impacts and assist with decision making when resources are limited to select the optimal technical strategy and minimize the impact to cost and schedule for other projects

  6. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  7. Patient identification and tube labelling

    DEFF Research Database (Denmark)

    van Dongen-Lases, Edmée C; Cornes, Michael P; Grankvist, Kjell

    2016-01-01

    of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent......Venous blood sampling (phlebotomy) is the most common invasive procedure performed in patient care. Guidelines on the correct practice of phlebotomy are available, including the H3-A6 guideline issued by the Clinical Laboratory Standards Institute (CLSI). As the quality of practices and procedures...... patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness...

  8. Drift tubes of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV PS Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows Linac 2 drift-tubes, suspended on stems coming from the top, in contrast to Linac 1, where the drift-tubes stood on stems coming from the bottom.

  9. Design and test of the Stirling-type pulse tube cryocooler

    Science.gov (United States)

    Hong, Yong-Ju; Ko, Junseok; Kim, Hyo-Bong; Yeom, Han-Kil; In, Sehwan; Park, Seong-Je

    2017-12-01

    Stirling type pulse tube cryocoolers are very attractive for cooling of diverse application because it has it has several inherent advantages such as no moving part in the cold end, low manufacturing cost and long operation life. To develop the Stirling-type pulse tube cryocooler, we need to design a linear compressor to drive the pulse tube cryocooler. A moving magnet type linear motor of dual piston configuration is designed and fabricated, and this compressor could be operated with the electric power of 100 W and the frequency up to 60 Hz. A single stage coaxial type pulse tube cold finger aiming at over 1.5 W at 80K is built and tested with the linear compressor. Experimental investigations have been conducted to evaluate their performance characteristics with respect to several parameters such as the phase shifter, the charging pressure and the operating frequency of the linear compressor.

  10. Optimizing the overall configuration of a He-cooled W-alloy divertor for a power plant

    International Nuclear Information System (INIS)

    Raffray, A.R.; Malang, S.; Wang, X.

    2009-01-01

    A number of different He-cooled divertor configurations have been proposed for magnetic fusion energy (MFE) power plant application. They range in scale from a plate configuration with characteristic dimension of the order of 1 m, to the ARIES-CS T-tube configuration with characteristic dimension of the order of 10 cm, to the EU FZK finger concept with characteristic dimension of the order of 1.5 cm. All these designs utilize tungsten or tungsten alloy as structural material. This paper considers the characteristics of the different divertor configurations and proposes the possibility of optimizing the design by combining different configurations in an integrated design based on the anticipated divertor heat flux profile.

  11. Contrast configuration influences grouping in apparent motion.

    Science.gov (United States)

    Ma-Wyatt, Anna; Clifford, Colin W G; Wenderoth, Peter

    2005-01-01

    We investigated whether the same principles that influence grouping in static displays also influence grouping in apparent motion. Using the Ternus display, we found that the proportion of group motion reports was influenced by changes in contrast configuration. Subjects made judgments of completion of these same configurations in a static display. Generally, contrast configurations that induced a high proportion of group motion responses were judged as more 'complete' in static displays. Using a stereo display, we then tested whether stereo information and T-junction information were critical for this increase in group motion. Perceived grouping was consistently higher for same contrast polarity configurations than for opposite contrast polarity configurations, regardless of the presence of stereo information or explicit T-junctions. Thus, while grouping in static and moving displays showed a similar dependence on contrast configuration, motion grouping showed little dependence on stereo or T-junction information.

  12. Metrics for measuring distances in configuration spaces.

    Science.gov (United States)

    Sadeghi, Ali; Ghasemi, S Alireza; Schaefer, Bastian; Mohr, Stephan; Lill, Markus A; Goedecker, Stefan

    2013-11-14

    In order to characterize molecular structures we introduce configurational fingerprint vectors which are counterparts of quantities used experimentally to identify structures. The Euclidean distance between the configurational fingerprint vectors satisfies the properties of a metric and can therefore safely be used to measure dissimilarities between configurations in the high dimensional configuration space. In particular we show that these metrics are a perfect and computationally cheap replacement for the root-mean-square distance (RMSD) when one has to decide whether two noise contaminated configurations are identical or not. We introduce a Monte Carlo approach to obtain the global minimum of the RMSD between configurations, which is obtained from a global minimization over all translations, rotations, and permutations of atomic indices.

  13. In-memory interconnect protocol configuration registers

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Kevin Y.; Roberts, David A.

    2017-09-19

    Systems, apparatuses, and methods for moving the interconnect protocol configuration registers into the main memory space of a node. The region of memory used for storing the interconnect protocol configuration registers may also be made cacheable to reduce the latency of accesses to the interconnect protocol configuration registers. Interconnect protocol configuration registers which are used during a startup routine may be prefetched into the host's cache to make the startup routine more efficient. The interconnect protocol configuration registers for various interconnect protocols may include one or more of device capability tables, memory-side statistics (e.g., to support two-level memory data mapping decisions), advanced memory and interconnect features such as repair resources and routing tables, prefetching hints, error correcting code (ECC) bits, lists of device capabilities, set and store base address, capability, device ID, status, configuration, capabilities, and other settings.

  14. In-memory interconnect protocol configuration registers

    Science.gov (United States)

    Cheng, Kevin Y.; Roberts, David A.

    2017-09-19

    Systems, apparatuses, and methods for moving the interconnect protocol configuration registers into the main memory space of a node. The region of memory used for storing the interconnect protocol configuration registers may also be made cacheable to reduce the latency of accesses to the interconnect protocol configuration registers. Interconnect protocol configuration registers which are used during a startup routine may be prefetched into the host's cache to make the startup routine more efficient. The interconnect protocol configuration registers for various interconnect protocols may include one or more of device capability tables, memory-side statistics (e.g., to support two-level memory data mapping decisions), advanced memory and interconnect features such as repair resources and routing tables, prefetching hints, error correcting code (ECC) bits, lists of device capabilities, set and store base address, capability, device ID, status, configuration, capabilities, and other settings.

  15. Miniature X-Ray Tubes

    Science.gov (United States)

    Bearman, Gregory H.

    1995-01-01

    Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

  16. Working session 3: Tubing integrity

    International Nuclear Information System (INIS)

    Cueto-Felgueroso, C.; Strosnider, J.

    1997-01-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group's discussions on these subjects, including conclusions and recommendations, are summarized in this article

  17. YouTube and Facebook

    DEFF Research Database (Denmark)

    Robertson, Scott P.; Vatrapu, Ravi; Medina, Richard

    This paper examines the links to YouTube from the Facebook “walls” of Barack Obama, Hillary Clinton, and John McCain over two years prior to the 2008 U.S. Presidential election. User-generated linkage patterns show how participants in these politically-related social networking dialogues used...... online video to make their points. We show a strong integration of the Web 2.0 and new media technologies of social networking and online video. We argue that political discussion in social networking environments can no longer be viewed as primarily textual, and that neither Facebook nor YouTube can...

  18. Visualization of the CMS python configuration system

    International Nuclear Information System (INIS)

    Erdmann, M; Fischer, R; Klimkovich, T; Mueller, G; Steggemann, J; Hegner, B; Hinzmann, A

    2010-01-01

    The job configuration system of the CMS experiment is based on the Python programming language. Software modules and their order of execution are both represented by Python objects. In order to investigate and verify configuration parameters and dependencies naturally appearing in modular software, CMS employs a graphical tool. This tool visualizes the configuration objects, their dependencies, and the information flow. Furthermore it can be used for documentation purposes. The underlying software concepts as well as the visualization are presented.

  19. A configurable CDS for the production laboratory

    CERN Document Server

    Meek, Irish

    2003-01-01

    Various aspects of a configurable chromatography data system (CDS) for the production laboratory are discussed. The Atlas CDS can be configured extensively to fit the production laboratory work flow and meet the needs of analysts. The CDS can also be configured to automatically create a sample sequence with the required number of injections and download methods to the dedicated instrument. The Atlas Quick Start wizard offers uses quick way of generating a sequence from a predefined template and starting a run. (Edited abstract).

  20. Visualization of the CMS Python Configuration System

    CERN Document Server

    Erdmann, M; Hegner, B; Hinzmann, A; Klimkovich, T; Muller, G; Steggemann, J

    2010-01-01

    The job configuration system of the CMS experiment is based on the Python programming language. Software modules and their order of execution are both represented by Python objects. In order to investigate and verify configuration parameters and dependencies naturally appearing in modular software, CMS employs a graphical tool. This tool visualizes the configuration objects, their dependencies, and the information flow. Furthermore it can be used for documentation purposes. The underlying software concepts as well as the visualization are presented.

  1. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  2. Steady state magnetic field configurations for the earth's magnetotail

    International Nuclear Information System (INIS)

    Hau, L.N.; Wolf, R.A.; Voigt, G.H.; Wu, C.C.

    1989-01-01

    The authors present a two-dimensional, force-balanced magnetic field model in which flux tubes have constant pVγ throughout an extended region of the nightside plasma sheet, between approximately 36 R E geocentric distance and the region of the inner edge of the plasma sheet. They have thus demonstrated the theoretical existence of a steady state magnetic field configuration that is force-balanced and also consistent with slow, lossless, adiabatic, earthward convection within the limit of the ideal MHD (isotropic pressure, perfect conductivity). The numerical solution was constructed for a two-dimensional magnetosphere with a rectangular magnetopause and nonflaring tail. The primary characteristics of the steady state convection solution are (1) a pressure maximum just tailward of the inner edge of the plasma sheet and (2) a deep, broad minimum in equatorial magnetic field strength B ze , also just tailward of the inner edge. The results are consistent with Erickson's (1985) convection time sequences, which exhibited analogous pressure peaks and B ze minima. Observations do not indicate the existence of a B ze minimum, on the average. They suggest that the configurations with such deep minima in B ze may be tearing-mode unstable, thus leading to substorm onset in the inner plasma sheet

  3. Thermal study of a residential water solar heating system with two different absorbing surface configurations; Estudo termico de um sistema solar de aquecimento de agua residencial para duas configuracoes de superficie absorvedora

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Rivaldo Ferreira

    2009-10-15

    A solar collector to be used in a system for heating water for bathing, whose main characteristics are its low cost and easy manufacturing and assembly is presented. The absorbing surface of the collector is formed by an aluminum plate with eight flaps where they lodge PVC pipes. The catchment area of solar radiation corresponds to 1.3 meters. The collector box was made of wood, it is covered by transparent glass and thermal insulation of tire chips and expanded polystyrene (EPS). Absorber tubes were connected in parallel through the use of PVC fittings and fixed to the plate by the use of metal poles and rivets. The entire absorber received paint fiat black for better absorption of sunlight. The system worked on a thermosyphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. The most efficient configuration for the connect purpose was determined. The solar collector was connected to a thermal reservoir, also alternative, low-cost forming the system of solar water heating. We evaluated thermal parameters that proved the viability of the heating system studied. (author)

  4. Dynamic Airspace Configuration Tool (DACT), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Metron Aviation will develop optimization algorithms and an automated tool for performing dynamic airspace configuration under different operational scenarios. The...

  5. Configuration of the ATLAS Trigger System

    CERN Document Server

    Elsing, M; Armstrong, S; Baines, J T M; Bee, C P; Biglietti, M; Bogaerts, A; Boisvert, V; Bosman, M; Brandt, S; Caron, B; Casado, M P; Cataldi, G; Cavalli, D; Cervetto, M; Comune, G; Corso-Radu, A; Di Mattia, A; Díaz-Gómez, M; Dos Anjos, A; Drohan, J; Ellis, Nick; Epp, B; Etienne, F; Falciano, S; Farilla, A; George, S; Ghete, V M; González, S; Grothe, M; Kaczmarska, A; Karr, K M; Khomich, A; Konstantinidis, N P; Krasny, W; Li, W; Lowe, A; Luminari, L; Ma, H; Meessen, C; Mello, A G; Merino, G; Morettini, P; Moyse, E; Nairz, A; Negri, A; Nikitin, N V; Nisati, A; Padilla, C; Parodi, F; Pérez-Réale, V; Pinfold, J L; Pinto, P; Polesello, G; Qian, Z; Rajagopalan, S; Resconi, S; Rosati, S; Scannicchio, D A; Schiavi, C; Segura, E; De Seixas, J M; Shears, T G; Sivoklokov, S Yu; Smizanska, M; Soluk, R A; Stanescu, C; Tapprogge, Stefan; Touchard, F; Vercesi, V; Watson, A; Wengler, T; Werner, P; Wheeler, S; Wickens, F J; Wiedenmann, W; Wielers, M; Zobernig, G; CHEP 2003 Computing in High Energy Physics

    2003-01-01

    In this paper a conceptual overview is given of the software foreseen to configure the ATLAS trigger system. Two functional software prototypes have been developed to configure the ATLAS Level-1 emulation and the High-Level Trigger software. Emphasis has been put so far on following a consistent approach between the two trigger systems and on addressing their requirements, taking into account the specific use-case of the `Region-of-Interest' mechanism for the ATLAS Level-2 trigger. In the future the configuration of the two systems will be combined to ensure a consistent selection configuration for the entire ATLAS trigger system.

  6. Comparison between four dissimilar solar panel configurations

    Science.gov (United States)

    Suleiman, K.; Ali, U. A.; Yusuf, Ibrahim; Koko, A. D.; Bala, S. I.

    2017-12-01

    Several studies on photovoltaic systems focused on how it operates and energy required in operating it. Little attention is paid on its configurations, modeling of mean time to system failure, availability, cost benefit and comparisons of parallel and series-parallel designs. In this research work, four system configurations were studied. Configuration I consists of two sub-components arranged in parallel with 24 V each, configuration II consists of four sub-components arranged logically in parallel with 12 V each, configuration III consists of four sub-components arranged in series-parallel with 8 V each, and configuration IV has six sub-components with 6 V each arranged in series-parallel. Comparative analysis was made using Chapman Kolmogorov's method. The derivation for explicit expression of mean time to system failure, steady state availability and cost benefit analysis were performed, based on the comparison. Ranking method was used to determine the optimal configuration of the systems. The results of analytical and numerical solutions of system availability and mean time to system failure were determined and it was found that configuration I is the optimal configuration.

  7. Governing Collaborative New Product Development : Toward a Configurational Perspective on the Role of Contracts

    NARCIS (Netherlands)

    Hofman, Erwin; Faems, Dries; Schleimer, Stephanie C.

    2017-01-01

    This study inductively explores the interplay among different contractual functions and their impact on project performance in collaborative new product development (NPD) projects. Applying a configurational perspective, contracts are conceptualized as bundles of different functions. In line with

  8. Guided flows in coronal magnetic flux tubes

    Science.gov (United States)

    Petralia, A.; Reale, F.; Testa, P.

    2018-01-01

    Context. There is evidence that coronal plasma flows break down into fragments and become laminar. Aims: We investigate this effect by modelling flows confined along magnetic channels. Methods: We consider a full magnetohydrodynamic (MHD) model of a solar atmosphere box with a dipole magnetic field. We compare the propagation of a cylindrical flow perfectly aligned with the field to that of another flow with a slight misalignment. We assume a flow speed of 200 km s-1 and an ambient magnetic field of 30 G. Results: We find that although the aligned flow maintains its cylindrical symmetry while it travels along the magnetic tube, the misaligned one is rapidly squashed on one side, becoming laminar and eventually fragmented because of the interaction and back-reaction of the magnetic field. This model could explain an observation made by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory of erupted fragments that fall back onto the solar surface as thin and elongated strands and end up in a hedge-like configuration. Conclusions: The initial alignment of plasma flow plays an important role in determining the possible laminar structure and fragmentation of flows while they travel along magnetic channels. Movies are available in electronic form at http://www.aanda.org

  9. Hydraulic study of drilling fluid flow in circular and annular tubes

    Energy Technology Data Exchange (ETDEWEB)

    Scheid, C.M.; Calcada, L.A.; Braga, E.R.; Paraiso, E.C.H. [Universidade Federal Rural do Rio de Janeiro (PPGEQ/UFRRJ), Seropedica, RJ (Brazil). Programa de Pos-Graduacao em Engenharia Quimica. Dept. de Engenharia Qumica], E-mail: calcada@ufrrj.br; Martins, A. L. [Petroleo Brasileiro S.A. (CENPES/PETROBRAS), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2011-10-15

    This study investigates the drilling fluid flow behavior of two water-based drilling fluids in circular and annular tubes. The study has four main objectives: 1) to evaluate correlations between the Power Law and the Casson rheological models, 2) to characterize the flow behavior, 3) to evaluate five hydraulic-diameter equations, and 4) to evaluate the correlations of five turbulent flow-friction factors. The experimental fluid flow loop consisted of one positive displacement pump of 25 HP connected to a 500-liter tank agitated by a 3-HP mixer. The fluids passed through six meters long tubes, arranged in three horizontal rows with independent inlets and outlets. The circular tubes had a 1 inch diameter and were configured as two concentric annular tubes. Annular Tube I had an outer diameter of 1 1/4 inch and an inner diameter of 1/2 inch. Annular Tube II had an outer diameter of 2 inches and an inner diameter of 3/4 inch. The results show that, for the fluids in exam, correlations proposed in the literature were inaccurate as far as predicting hydraulic diameter, estimating pressure drop, and defining the flow regime. In general, the performance of those correlations depended on the fluid properties and on the system's geometry. Finally, literature parameters for some of the correlations were estimated for the two drilling fluids studied. These estimations improved the predictive capacity of calculating the friction factor for real drilling fluids applications for both circular and annular tubes. (author)

  10. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  11. Configurable Multi-Purpose Processor

    Science.gov (United States)

    Valencia, J. Emilio; Forney, Chirstopher; Morrison, Robert; Birr, Richard

    2010-01-01

    Advancements in technology have allowed the miniaturization of systems used in aerospace vehicles. This technology is driven by the need for next-generation systems that provide reliable, responsive, and cost-effective range operations while providing increased capabilities such as simultaneous mission support, increased launch trajectories, improved launch, and landing opportunities, etc. Leveraging the newest technologies, the command and telemetry processor (CTP) concept provides for a compact, flexible, and integrated solution for flight command and telemetry systems and range systems. The CTP is a relatively small circuit board that serves as a processing platform for high dynamic, high vibration environments. The CTP can be reconfigured and reprogrammed, allowing it to be adapted for many different applications. The design is centered around a configurable field-programmable gate array (FPGA) device that contains numerous logic cells that can be used to implement traditional integrated circuits. The FPGA contains two PowerPC processors running the Vx-Works real-time operating system and are used to execute software programs specific to each application. The CTP was designed and developed specifically to provide telemetry functions; namely, the command processing, telemetry processing, and GPS metric tracking of a flight vehicle. However, it can be used as a general-purpose processor board to perform numerous functions implemented in either hardware or software using the FPGA s processors and/or logic cells. Functionally, the CTP was designed for range safety applications where it would ultimately become part of a vehicle s flight termination system. Consequently, the major functions of the CTP are to perform the forward link command processing, GPS metric tracking, return link telemetry data processing, error detection and correction, data encryption/ decryption, and initiate flight termination action commands. Also, the CTP had to be designed to survive and

  12. Mechanical support for straw tubes

    International Nuclear Information System (INIS)

    Joestlein, H.

    1990-01-01

    A design is proposed for mounting a large number of straw tubes to form an SSC central tracking chamber. The assembly is precise and of very low mass. The fabrication is modular and can be carried out with a minimum of tooling and instrumentation. Testing of modules is possible prior to the final assembly. 4 figs

  13. OurTube / David Talbot

    Index Scriptorium Estoniae

    Talbot, David

    2009-01-01

    USA California Ülikooli töötajate Abram Stern'i ja Michael Dale'i poolt 2005. a. algatatud USA kongressis peetud kõnede videoremiksidest ja nende poolt loodud veebisaidist Metavid.org. Ka YouTube keskkonnast ja wikipedia katsetustest muuta oma keskkond multimeedialisemaks

  14. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  15. Working session 1: Tubing degradation

    International Nuclear Information System (INIS)

    Kharshafdjian, G.; Turluer, G.

    1997-01-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to open-quotes develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.close quotes Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym open-quotes MESSclose quotes by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed

  16. Case of nasogastric tube dysfunction.

    Science.gov (United States)

    Rainer, Florian; Prenner, Guenther; Binder, Lukas Peter; Fickert, Peter; Plank, Johannes

    2018-01-05

    An elderly female patient was admitted to intensive care for prolonged vasopressor therapy and mechanical ventilation after cardiac arrest and acute percutaneous coronary intervention. Antiplatelet, thyroid hormone replacement and statin therapies were administered through a 14-French nasogastric tube (Nestlé Health Science) and enteral feeding was initiated. Correct position of the nasogastric tube was confirmed radiologically. On the seventh day in the intensive care, our patient was seen to regurgitate soft crumbs into her mouth. The blocked nasogastric tube was removed, but attempts to reinsert another tube failed.Upper GI endoscopy revealed an obstruction of the oesophagus with a milky-yellowish caseous substance 20 cm from the incisors (figure 1). The proximal part of the mass showed a central hole and ring-shaped layers resembling the cut face of a tree trunk.gutjnl;gutjnl-2017-315619v1/F1F1F1Figure 1Obstruction of the oesophagus with a milky-yellowish caseous substance. What caused the obstruction?How should we manage such a problem? © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Kundt's Tube Experiment Using Smartphones

    Science.gov (United States)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2015-01-01

    This article deals with a modern version of Kundt's tube experiment. Using economic instruments and a couple of smartphones, it is possible to "see" nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  18. Steam generator tube integrity program

    International Nuclear Information System (INIS)

    Diercks, D.R.; Shack, W.J.

    1996-01-01

    The degradation of steam generator tubes in pressurized water nuclear reactors continues to be a serious problem, and the US Nuclear Regulatory Commission (NRC) is developing a performance-based rule and regulatory guide for steam generator tube integrity. To support the evaluation of industry-proposed implementation of these performance-based criteria, the NRC is sponsoring a new research program at Argonne National Laboratory on steam generator tubing degradation. The objective of the new program is to provide the necessary experimental data and predictive correlations and models that will permit the NRC to independently evaluate the integrity of steam generator tubes. The technical work in the program is divided into four tasks, (1) assessment of inspection reliability, (2) research on in-service inspection technology, (3) research on degradation modes and integrity, and (4) development of methodology and technical assessments for current and emerging regulatory issues. The objectives of and planned research activities under each of these four tasks are described here. (orig.)

  19. Tube in shell heat exchangers

    International Nuclear Information System (INIS)

    Hayden, O.; Willby, C.R.; Sheward, G.E.; Ormrod, D.T.; Firth, G.F.

    1980-01-01

    An improved tube-in-shell heat exchanger to be used between liquid metal and water is described for use in the liquid metal coolant system of fast breeder reactors. It is stated that this design is less prone to failures which could result in sodium water reactions than previous exchangers. (UK)

  20. Tubing with high corrosion resistance

    Science.gov (United States)

    Ioffe, A. V.; Tetyueva, T. V.; Vyboyshchik, M. A.; Trifonova, E. A.; Lutsenko, E. S.

    2010-07-01

    The optimum chemical composition and the regime for heat treatment of heat-resistant steel 15Kh5M are determined for the production of tubing with strength of group L80 (API 5CT) and high cold resistance and resistance to carbon dioxide and sulfurated hydrogen corrosion at low alloying additives of chromium and molybdenum.

  1. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube ...

  2. Welding the CNGS decay tube

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    3.6 km of welds were required for the 1 km long CERN Neutrinos to Gran Sasso (CNGS) decay tube, in which particles produced in the collision with a proton and a graphite target will decay into muons and muon neutrinos. Four highly skilled welders performed this delicate task.

  3. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  4. Experiment Configurations for the DAST

    Science.gov (United States)

    1978-01-01

    This image shows three vehicle configurations considered for the Drones for Aerodynamic and Structural Testing (DAST) program, conducted at NASA's Dryden Flight Research Center between 1977 and 1983. The DAST project planned for three wing configurations. These were the Instrumented Standard Wing (ISW), the Aeroelastic Research Wing-1 (ARW-1), and the ARW-2. After the DAST-1 crash, project personnel fitted a second Firebee II with a rebuilt ARW-1 wing. Due to the project's ending, it never flew the ARW-2 wing. These are the image contact sheets for each image resolution of the NASA Dryden Drones for Aerodynamic and Structural Testing (DAST) Photo Gallery. From 1977 to 1983, the Dryden Flight Research Center, Edwards, California, (under two different names) conducted the DAST Program as a high-risk flight experiment using a ground-controlled, pilotless aircraft. Described by NASA engineers as a 'wind tunnel in the sky,' the DAST was a specially modified Teledyne-Ryan BQM-34E/F Firebee II supersonic target drone that was flown to validate theoretical predictions under actual flight conditions in a joint project with the Langley Research Center, Hampton, Virginia. The DAST Program merged advances in electronic remote control systems with advances in airplane design. Drones (remotely controlled, missile-like vehicles initially developed to serve as gunnery targets) had been deployed successfully during the Vietnamese conflict as reconnaissance aircraft. After the war, the energy crisis of the 1970s led NASA to seek new ways to cut fuel use and improve airplane efficiency. The DAST Program's drones provided an economical, fuel-conscious method for conducting in-flight experiments from a remote ground site. DAST explored the technology required to build wing structures with less than normal stiffness. This was done because stiffness requires structural weight but ensures freedom from flutter-an uncontrolled, divergent oscillation of the structure, driven by aerodynamic

  5. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Science.gov (United States)

    2010-04-01

    ... intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with... § 876.9. (2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part...

  6. Schizophrenia on YouTube.

    Science.gov (United States)

    Nour, Matthew M; Nour, Murraih H; Tsatalou, Olga-Maria; Barrera, Alvaro

    2017-01-01

    YouTube ( www.youtube.com ) is the most popular video-sharing Web site on the Internet and is used by medical students as a source of information regarding mental health conditions, including schizophrenia. The accuracy and educational utility of schizophrenia presentations on YouTube are unknown. The purpose of this study was to analyze the accuracy of depictions of psychosis in the context of a diagnosis of schizophrenia (referred to in this article as "acute schizophrenia") on YouTube and to assess the utility of these videos as educational tools for teaching medical students to recognize the clinical features of acute schizophrenia. YouTube was searched for videos purporting to show acute schizophrenia. Eligible videos were independently rated by two consultant psychiatrists on two separate occasions 22 days apart for diagnostic accuracy, psychopathology, and educational utility. Videos (N=4,200) were assessed against predefined inclusion and exclusion criteria. The majority were not eligible for further analysis, mostly because they did not claim to show a patient with schizophrenia (74%) or contained duplicated content (11%). Of 35 videos that met the eligibility and adequacy criteria, only 12 accurately depicted acute schizophrenia. Accurate videos were characterized by persecutory delusions (83%), inappropriate affect (75%), and negative symptoms (83%). Despite the fact that 83% of accurate videos were deemed to have good educational utility compared with 15% of inaccurate videos, accurate and inaccurate videos had similar view counts (290,048 versus 186,124). Schizophrenia presentations on YouTube offer a distorted picture of the condition.

  7. Preparation of metallic uranium tubes

    International Nuclear Information System (INIS)

    Lerouge, G.; Decours, J.

    1964-01-01

    The production furnace is an induction heated vacuum furnace having a capacity at the moment of 250 kg. Previously the crucible was heated by the inductor, the mould being outside the inductor. The tubes thus produced contained cavities, the alloy structure was fine; this was cold-mould casting, At the moment the top of the moulds are pre-heated, this is the so called hot-mould casting. This method has the advantage of eliminating the cavities but leads to a less fine microstructure. The alloy used for the 18 x 40 mm and 23 x 43 mm tubes is U-Mo (1.1 per cent). Since the moulds are now heated at the top, the solidification of the metal is very slow in this zone leading to a pronounced γ grain, whereas towards the base the faster cooling leads to a smaller γ grain. The γ structure depends essentially on the solidification rate and on the time spent in this zone. In order to obtain a fine and homogeneous grain along the whole length of the tube, a controlled cooling treatment is effected. It consists in heating the uranium tubes in the γ place and then in cooling them at a rate of between 20 and 50 deg C/mm down to 400 deg C. The 77 x 95 mm and 54 x 70 mm annular elements are at the moment being produced for research purposes. Their preparation is similar to that of 18 x 40 mm and 23 x 43 mm elements. The 77 x 95 mm tubes are at the moment made from U-Cr alloy (0.1 per cent); because of their size, their preparation is carried out in 600 mm diameter furnaces. (authors) [fr

  8. Rejection index for pressure tubes

    International Nuclear Information System (INIS)

    Mitchell, A.B.; Meneley, D.

    1989-10-01

    The objective of the present study was to establish a set of criteria (or Rejection Index) which could be used to decide whether a zirconium-2 1/2 w/o niobium pressure tube in a CANDU reactor should be removed from service due to in-service degradation. A critique of key issues associated with establishing a realistic rejection index was prepared. Areas of uncertainty in available information were identified and recommendations for further analysis and laboratory testing made. A Rejection Index based on the following limits has been recommended: 1) Limits related to design intent and normal operation: any garter spring must remain within the tolerance band specified for its design location; the annulus gas system must normally be operated in a circulating mode with a procedure in place for purging to prevent accumulation of deuterium. It must remain sensitive to leaks into any part of the systems; and pressure tube dimensions and distortions must be limited to maintain the fuel channels within the original design intent; 2) Limits related to defect tolerance: adequate time margins between occurrence of a leaking crack and unstable failure must be demonstrated for all fuel channels; long lap-type flaws are unacceptable; crack-like defects of any size are unacceptable; and score marks, frat marks and other defects with contoured profiles must fall below certain depth, length and stress intensity limits; and 3) Limits related to property degradation: at operating temperature each pressure tube must be demonstrated to have a critical length in excess of a stipulated value; the maximum equivalent hydrogen level in any pressure tube should not exceed a limit which should be defined taking into account the known history of that tube; the maximum equivalent hydrogen level in any rolled joint should not exceed a limit which is presently recommended as 200 ppm equivalent hydrogen; and the maximum diametral creep strain should be limited to less than 5%

  9. Improving the calandria tubes for CANDU reactors

    International Nuclear Information System (INIS)

    Coleman, C.E.; Fong, R.W.L.; Doubt, G.L.

    1997-01-01

    CANDU calandria tubes are made from annealed Zircaloy-2 sheet formed into a cylinder and welded along its length to make the tube. The current calandria tubes have given exemplary service for many years. With more stringent regulations and the need to accommodate warm cooling water in tropical countries, we started a development program to increase the margins for failure during postulated accidents. These improvements involve increasing the tube strength and optimising the heat-transfer from an excessively hot fuel channel to the cool moderator. If the postulated accident involves a pressure tube break, it would be desirable if the calandria tube withstood the full pressure of the heat-transport system. The weakest link in current calandria tubes is the weld. Thickening the weld can increase the strength by 20% while seamless tubes can be 45% stronger than current tubes. The latter tubes can hold full system pressure for many hours without failure. If during the postulated accident the fuel and pressure tube become excessively hot but do not touch the calandria tube, the radiant heat loss must be maximised. Current calandria tubes have an absorptivity (emissivity) of about 0.2. To protect the fuel and the fuel channel we have devised a finish to the inside surface of the calandria tube that increases the emissivity to 0.7. If during the postulated accident the hot pressure tube touches the cool calandria tube, the contact conductance and the critical heat flux must be optimised to ensure nucleate boiling of the moderator at the outside surface of the calandria tube and therefore efficient exploitation of the moderator as a heat sink. In laboratory tests small ridges on the inside surface and roughening of the outside surface have been shown to increase the margins against failure and increase the possible moderator temperatures thus providing the opportunity to decrease the cost of the moderator heat-exchange system and remove restrictions on reactor operation in

  10. Preservative loss from silicone tubing during filling processes.

    Science.gov (United States)

    Saller, Verena; Matilainen, Julia; Rothkopf, Christian; Serafin, Daniel; Bechtold-Peters, Karoline; Mahler, Hanns-Christian; Friess, Wolfgang

    2017-03-01

    Significant loss of preservative was observed during filling of drug products during filling line stops. This study evaluated the losses of three commonly used preservatives in protein drugs, i.e. benzyl alcohol, phenol, and m-cresol. Concentration losses during static incubation were quantified and interpreted with regard to the potential driving forces for the underlying sorption, diffusion, and desorption steps. Partitioning from the solution into the silicone polymer was identified as the most decisive parameter for the extent of preservative loss. Additionally, the influence of tubing inner diameter, starting concentration as well as silicone tubing type was evaluated. Theoretical calculations assuming equilibrium between solution and tubing inner surface and one-directional diffusion following Fick's first law were used to approximate experimental data. Since significant losses were found already after few minutes, adequate measures must be taken to avoid deviations during filling of preservative-containing protein solutions that may impact product quality or antimicrobial efficacy. As a possible alternative to the highly permeable silicone tubing, a specific make of fluoropolymer tubing was identified being suitable for peristaltic pumps and not showing any preservative losses. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A case of a 'lost' nasogastric tube.

    Science.gov (United States)

    Sankar, V; Shakeel, M; Keh, S; Ah-See, K W

    2012-12-01

    To present the case of a 'lost' nasogastric tube and to highlight the importance of imaging and/or chest X-ray after nasogastric tube insertion, especially in unreliable patients. A 50-year-old man, undergoing radiotherapy treatment for squamous cell carcinoma of the tongue base, was admitted for pain control and nasogastric tube feeding. This patient required multiple nasogastric tubes over a two-week period. The patient repeatedly denied pulling the nasogastric tube out and we were unable to establish the exact mode of nasogastric tube removal. On one such occasion another tube was inserted and a check X-ray showed two feeding tubes; the latest one was lying in the left main bronchus and the old nasogastric tube was observed in the oesophagus, with its upper end jutting above the hypopharynx. It was apparent that the patient had somehow cut the tube and swallowed it. This case not only illustrates the importance of flexible nasendoscopy and/or chest X-ray for checking the position of the nasogastric tube, but also highlights that some patients are not tolerant of nasogastric tubes. The use of nasogastric tubes should be avoided in these patients to prevent any self-inflicted injury.

  12. Deformed configurations, band structures and spectroscopic ...

    Indian Academy of Sciences (India)

    2014-03-20

    Mar 20, 2014 ... The deformed configurations and rotational band structures in =50 Ge and Se nuclei are studied by deformed Hartree–Fock with quadrupole constraint and angular momentum projection. Apart from the `almost' spherical HF solution, a well-deformed configuration occurs at low excitation. A deformed ...

  13. Control Configuration Selection for Multivariable Nonlinear Systems

    DEFF Research Database (Denmark)

    Shaker, Hamid Reza; Komareji, Mohammad

    2012-01-01

    Control configuration selection is the procedure of choosing the appropriate input and output pairs for the design of SISO (or block) controllers. This step is an important prerequisite for a successful industrial control strategy. In industrial practices, it is often the case that systems, which...... diagonal controller structure. The interaction measure is used for control configuration selection of the nonlinear quadruple-tank process....

  14. System for Configuring Modular Telemetry Transponders

    Science.gov (United States)

    Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A system for configuring telemetry transponder cards uses a database of error checking protocol data structures, each containing data to implement at least one CCSDS protocol algorithm. Using a user interface, a user selects at least one telemetry specific error checking protocol from the database. A compiler configures an FPGA with the data from the data structures to implement the error checking protocol.

  15. Static Equilibrium Configurations of Charged Metallic Bodies ...

    African Journals Online (AJOL)

    When charged particles are placed on an uncharged metallic body, the charged particles redistribute themselves along the surface of the body until they reach a point or a configuration that no net tangential force is experienced on each particle. That point is referred to as electrostatic equilibrium configuration or simply as ...

  16. Measures on two-component configuration spaces

    Directory of Open Access Journals (Sweden)

    D.L. Finkelshtein

    2009-01-01

    Full Text Available We study the measures on the configuration spaces of particles of two types. Gibbs measures on such spaces are described. Main properties of corresponding relative energy densities and correlation functions are considered. In particular, we show that a support set for such Gibbs measure is the set of pairs of non-intersected configurations.

  17. TWRS authorization basis configuration control summary

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, D.P.

    1997-12-26

    This document was developed to define the Authorization Basis management functional requirements for configuration control, to evaluate the management control systems currently in place, and identify any additional controls that may be required until the TWRS [Tank Waste Remediation System] Configuration Management system is fully in place.

  18. Improving the quotation process with product configuration

    DEFF Research Database (Denmark)

    Hvam, Lars; Christensen, Simon Pape

    2006-01-01

    How can product configuration support the process of engineering highly complex industrial products? This article describes how an IT-based product configuration system was developed to support the process of mak-ing budget quotations. The article is based on a research project carried out...

  19. Marking up lattice QCD configurations and ensembles

    Energy Technology Data Exchange (ETDEWEB)

    P.Coddington; B.Joo; C.M.Maynard; D.Pleiter; T.Yoshie

    2007-10-01

    QCDml is an XML-based markup language designed for sharing QCD configurations and ensembles world-wide via the International Lattice Data Grid (ILDG). Based on the latest release, we present key ingredients of the QCDml in order to provide some starting points for colleagues in this community to markup valuable configurations and submit them to the ILDG.

  20. TWRS authorization basis configuration control summary

    International Nuclear Information System (INIS)

    Mendoza, D.P.

    1997-01-01

    This document was developed to define the Authorization Basis management functional requirements for configuration control, to evaluate the management control systems currently in place, and identify any additional controls that may be required until the TWRS [Tank Waste Remediation System] Configuration Management system is fully in place

  1. Microsoft System Center Configuration Manager advanced deployment

    CERN Document Server

    Coupland, Martyn

    2014-01-01

    If you are an experienced Configuration Manager administrator looking to advance your career or get more from your current environment, then this book is ideal for you. Prior experience of deploying and managing a Configuration Manager site would be helpful in following the examples throughout this book.

  2. Exercise in Configurable Products using Creo parametric

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    2017-01-01

    Family tables is a long know method with ProEngineer/Creo parametric to make families of products – like families of bolts and roller bearings. Configurable Products expand these possibilities in two major ways: First it makes configurable assemblies possible where one topologically different...

  3. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  4. Speeding up Derivative Configuration from Product Platforms

    Directory of Open Access Journals (Sweden)

    Ruben Heradio

    2014-06-01

    Full Text Available To compete in the global marketplace, manufacturers try to differentiate their products by focusing on individual customer needs. Fulfilling this goal requires that companies shift from mass production to mass customization. Under this approach, a generic architecture, named product platform, is designed to support the derivation of customized products through a configuration process that determines which components the product comprises. When a customer configures a derivative, typically not every combination of available components is valid. To guarantee that all dependencies and incompatibilities among the derivative constituent components are satisfied, automated configurators are used. Flexible product platforms provide a big number of interrelated components, and so, the configuration of all, but trivial, derivatives involves considerable effort to select which components the derivative should include. Our approach alleviates that effort by speeding up the derivative configuration using a heuristic based on the information theory concept of entropy.

  5. Configural face encoding and spatial frequency information.

    Science.gov (United States)

    Boutet, Isabelle; Collin, Charles; Faubert, Jocelyn

    2003-10-01

    Configural relations and a critical band of spatial frequencies (SFs) in the middle range are particularly important for face recognition. We report the results of four experiments in which the relationship between these two types of information was examined. In Experiments 1, 2A, and 2B, the face inversion effect (FIE) was used to probe configural face encoding. Recognition of upright and inverted faces and nonface objects was measured in four conditions: a no-filter condition and three SF conditions (low, medium, and high frequency). We found significant FIEs of comparable magnitudes for all frequency conditions. In Experiment 3, discrimination of faces on the basis of either configural or featural modifications was measured under the same four conditions. Although the ability to discriminate configural modifications was superior in the medium-frequency condition, so was the ability to discriminate featural modifications. We conclude that the band of SF that is critical for face recognition does not contribute preferentially to configural encoding.

  6. Industrial requirements for interactive product configurators

    DEFF Research Database (Denmark)

    Queva, Matthieu Stéphane Benoit; Probst, Christian W.; Vikkelsøe, Per

    2009-01-01

    The demand for highly customized products at low cost is driving the industry towards Mass Customization. Interactive product configurators play an essential role in this new trend, and must be able to support more and more complex features. The purpose of this paper is, firstly, to identify requ...... requirements for modern interactive configurators. Existing modeling and solving technologies for configuration are then reviewed and their limitations discussed. Finally, a proposition for a future product configuration system is described.......The demand for highly customized products at low cost is driving the industry towards Mass Customization. Interactive product configurators play an essential role in this new trend, and must be able to support more and more complex features. The purpose of this paper is, firstly, to identify...

  7. Configuration Management Plan for K Basins

    International Nuclear Information System (INIS)

    Weir, W.R.; Laney, T.

    1995-01-01

    This plan describes a configuration management program for K Basins that establishes the systems, processes, and responsibilities necessary for implementation. The K Basins configuration management plan provides the methodology to establish, upgrade, reconstitute, and maintain the technical consistency among the requirements, physical configuration, and documentation. The technical consistency afforded by this plan ensures accurate technical information necessary to achieve the mission objectives that provide for the safe, economic, and environmentally sound management of K Basins and the stored material. The configuration management program architecture presented in this plan is based on the functional model established in the DOE Standard, DOE-STD-1073-93, open-quotes Guide for Operational Configuration Management Programclose quotes

  8. SRP [Salt Repository Project] configuration management plan

    International Nuclear Information System (INIS)

    1987-01-01

    This configuration management plan describes the organization, policies, and procedures that will be used on the Salt Repository Project (SRP) to implement the configuration management disciplines and controls. Configuration management is a part of baseline management. Baseline management is defined in the SRP Baseline Procedures Notebook and also includes cost and schedule baselines. Configuration management is a discipline applying technical and administrative direction and surveillance to identify and document the functional and physical characteristics of an item, to control changes to those characteristics, to record and report change processing and implementation status, and to audit the results. Configuration management is designed as a project management tool to determine and control baselines, and ensure and document all components of a project interface both physically and functionally. The purpose is to ensure that the product acquired satisfies the project's technical and operational requirements, and that the technical requirements are clearly defined and controlled throughout the development and acquisition process. 5 figs

  9. Evolution of the Configuration Database Design

    International Nuclear Information System (INIS)

    Salnikov, A.

    2006-01-01

    The BABAR experiment at SLAC successfully collects physics data since 1999. One of the major parts of its on-line system is the configuration database which provides other parts of the system with the configuration data necessary for data taking. Originally the configuration database was implemented in the Objectivity/DB ODBMS. Recently BABAR performed a successful migration of its event store from Objectivity/DB to ROOT and this prompted a complete phase-out of the Objectivity/DB in all other BABAR databases. It required the complete redesign of the configuration database to hide any implementation details and to support multiple storage technologies. In this paper we describe the process of the migration of the configuration database, its new design, implementation strategy and details

  10. [Tracheal intubation with Parker Flex-Tip tubes assisted by tube-guiding devices].

    Science.gov (United States)

    Mizuno, Ju; Morita, Shigeho; Suzuki, Maya; Arita, Hideko; Hanaoka, Kazuo

    2010-04-01

    In tracheal intubation assisted by tube-guiding devices passing through the tube, such as fiberoptic scopes, bougies, tracheal tube exchange catheters, and light wands, passage of the tube-guiding device, by itself, is often easy. But advancing a tracheal tube with a conventional distal tip over these tube-guiding devices is frequently difficult or impossible, because its rigid, side-beveled tip frequently catches on anatomical features of the airway. A novel tracheal tube, the Parker Flex-Tip tube (Parker Medical, Colorado, USA) has a centered, curved, tapered and flexible distal tip that passes through the airway faster and easier than conventional tracheal tubes. As it is advanced along a tube-guiding device, the tip of the Parker tube travels along the midline of the airway, without the gap that usually exists between the distal edge of a conventional tracheal tube and the tube-guiding device. The gapless, midline travel of the Parker tube leads to a greater incidence of first-attempt intubation success with tube-guiding devices, because there is less risk of tube tip hang-ups on the arytenoids and the vocal cords. Clinically, use of the Parker tube is helpful for oral and nasal intubations, especially in patients with difficult airways.

  11. Outcomes of Infants with Home Tube Feeding: Comparing Nasogastric Versus Gastrostomy Tubes

    Science.gov (United States)

    Khalil, Syed Tariq; Uhing, Michael R.; Duesing, Lori; Visotcky, Alexis; Tarima, Sergey; Nghiem-Rao, T. Hang

    2017-01-01

    Background Determine the tube-related complications and feeding outcomes of infants discharged home from the NICU with nasogastric (NG) tube feeding or gastrostomy (G-tube) feeding. Material & Methods We performed a chart review of 335 infants discharged from our NICU with home NG tube or G-tube feeding between January 2009 – December 2013. The primary outcome was the incidence of feeding tube-related complications requiring emergency department (ED) visits, hospitalizations, or deaths. Secondary outcome was feeding status at 6 months post-discharge. Univariate and multivariate analyses were conducted. Results There were 322 infants discharged with home enteral tube feeding, 84 NG tube and 238 G-tube, with available out-patient data for the 6 month post-discharge period. A total of 115 ED visits, 28 hospitalizations, and 2 deaths were due to a tube-related complication. The incidence of tube-related complications requiring an ED visit was significantly higher in the G-tube group compared to the NG tube group (33.6% vs 9.5%, p tube related complication. By 6 months post-discharge, full oral feeding was achieved in 71.4% of infants in the NG tube group compared to 19.3% in the G-tube group (p tube and percentage of oral feeding at discharge were significantly associated with continued tube feeding at 6 months post-discharge. Conclusion Home NG tube feeding is associated with fewer ED visits for tube-related complications compared to home G-tube feeding. There may be some infants who could benefit from a trial home NG tube feeding. PMID:27647478

  12. Outcomes of Infants With Home Tube Feeding: Comparing Nasogastric vs Gastrostomy Tubes.

    Science.gov (United States)

    Khalil, Syed Tariq; Uhing, Michael R; Duesing, Lori; Visotcky, Alexis; Tarima, Sergey; Nghiem-Rao, T Hang

    2017-11-01

    The aim of this study was to determine the tube-related complications and feeding outcomes of infants discharged home from the neonatal intensive care unit (NICU) with nasogastric (NG) tube feeding or gastrostomy (G-tube) feeding. We performed a chart review of 335 infants discharged from our NICU with home NG tube or G-tube feeding between January 2009 and December 2013. The primary outcome was the incidence of feeding tube-related complications requiring emergency department (ED) visits, hospitalizations, or deaths. Secondary outcome was feeding status at 6 months postdischarge. Univariate and multivariate analyses were conducted. There were 322 infants discharged with home enteral tube feeding (NG tube, n = 84; G-tube, n = 238), with available outpatient data for the 6-month postdischarge period. A total of 115 ED visits, 28 hospitalizations, and 2 deaths were due to a tube-related complication. The incidence of tube-related complications requiring an ED visit was significantly higher in the G-tube group compared with the NG tube group (33.6% vs 9.5%, P tube-related complication. By 6 months postdischarge, full oral feeding was achieved in 71.4% of infants in the NG tube group compared with 19.3% in the G-tube group ( P tube and percentage of oral feeding at discharge were significantly associated with continued tube feeding at 6 months postdischarge. Home NG tube feeding is associated with fewer ED visits for tube-related complications compared with home G-tube feeding. Some infants could benefit from a trial home NG tube feeding.

  13. In service inspection for steam generator tubes

    International Nuclear Information System (INIS)

    Comby, R.; Eyrolles, Ph.

    1988-01-01

    In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations [fr

  14. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  15. The accessory fallopian tube: A rare anomaly

    Directory of Open Access Journals (Sweden)

    Kusum R Gandhi

    2012-01-01

    Full Text Available This paper presents a rare anatomical variation in the form of accessory fallopian tube on right side. The duplication of fallopian tube was observed in a 34-year-old female during routine undergraduate dissection in our department. Fallopian tube is the part of uterus that carries the ovum from the ovary to the uterus. Accessory fallopian tube is the congenital anomaly attached to the ampullary part of main tube. This accessory tube is common site of pyosalpinx, hydrosalpinx, cystic swelling and torsion. The ovum released by the ovary may also be captured by the blind accessory tube leading to infertility or ectopic pregnancy. Hence, all patients of infertility or pelvic inflammatory disease should be screened to rule out the presence of accessory fallopian tube and if encountered should be removed.

  16. Chemical cleaning specification: few tube test model

    International Nuclear Information System (INIS)

    Hampton, L.V.; Simpson, J.L.

    1979-09-01

    The specification is for the waterside chemical cleaning of the 2 1/4 Cr - 1 Mo steel steam generator tubes. It describes the reagents and conditions for post-chemical cleaning passivation of the evaporator tubes

  17. Prestressed Carbon Fiber Composite Overwrapped Gun Tube

    National Research Council Canada - National Science Library

    Littlefield, Andrew; Hyland, Edward

    2006-01-01

    .... Using composite materials not only directly removes weight from the gun tube but, by better balancing the tube, allows the use of smaller drive systems, thus further enhancing the system weight loss...

  18. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  19. Ceramic vacuum tubes for geothermal well logging

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, R.D.

    1977-01-01

    Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.

  20. Mechanisms of Injury and Countermeasures for EVA Associated Upper Extremity Medical Issues: Extended Vent Tube Study

    Science.gov (United States)

    Jones, Jeff; Hoffman, Ron; Harvey, Craig; Bowen, C. K.; Hudy, C. E.; Tuxhorn, Jennifer; Gernhardt, Mike; Scheuring, Richard A.

    2007-01-01

    The goal of this study is to determine the role that moisture plays in the injury to the fingers and fingernails during EVA training operations in the Neutral Buoyancy Laboratory. Current Extravehicular Mobility Unit (EMU, with a PLSS) as configured in the NBL was used for all testing and a vent tube was extended down a single arm of the crewmember during the test; vent tube was moved between left and right arm to serve as experimental condition being investigated and the other arm served as control condition.