WorldWideScience

Sample records for triple resonance experiments

  1. A set of triple-resonance nuclear magnetic resonance experiments for structural characterization of organophosphorus compounds in mixture samples

    Energy Technology Data Exchange (ETDEWEB)

    Koskela, Harri, E-mail: Harri.T.Koskela@helsinki.fi [VERIFIN, University of Helsinki, P.O. Box 55, FIN-00014 Helsinki (Finland)

    2012-11-02

    Highlights: Black-Right-Pointing-Pointer New {sup 1}H, {sup 13}C, {sup 31}P triple-resonance NMR pulse experiments. Black-Right-Pointing-Pointer Analysis of organophosphorus (OP) compounds in complex matrix. Black-Right-Pointing-Pointer Selective extraction of {sup 1}H, {sup 31}P, and {sup 13}C chemical shifts and connectivities. Black-Right-Pointing-Pointer More precise NMR identification of OP nerve agents and their degradation products. - Abstract: The {sup 1}H, {sup 13}C correlation NMR spectroscopy utilizes J{sub CH} couplings in molecules, and provides important structural information from small organic molecules in the form of carbon chemical shifts and carbon-proton connectivities. The full potential of the {sup 1}H, {sup 13}C correlation NMR spectroscopy has not been realized in the Chemical Weapons Convention (CWC) related verification analyses due to the sample matrix, which usually contains a high amount of non-related compounds obscuring the correlations of the relevant compounds. Here, the results of the application of {sup 1}H, {sup 13}C, {sup 31}P triple-resonance NMR spectroscopy in characterization of OP compounds related to the CWC are presented. With a set of two-dimensional triple-resonance experiments the J{sub HP}, J{sub CH} and J{sub PC} couplings are utilized to map the connectivities of the atoms in OP compounds and to extract the carbon chemical shift information. With the use of the proposed pulse sequences the correlations from the OP compounds can be recorded without significant artifacts from the non-OP compound impurities in the sample. Further selectivity of the observed correlations is achieved with the application of phosphorus band-selective pulse in the pulse sequences to assist the analysis of multiple OP compounds in mixture samples. The use of the triple-resonance experiments in the analysis of a complex sample is shown with a test mixture containing typical scheduled OP compounds, including the characteristic degradation

  2. Triple resonance 15N NMR relaxation experiments for studies of intrinsically disordered proteins

    Czech Academy of Sciences Publication Activity Database

    Srb, Pavel; Nováček, J.; Kadeřávek, P.; Rabatinová, Alžběta; Krásný, Libor; Žídková, Jitka; Bobálová, Janette; Sklenář, V.; Žídek, L.

    2017-01-01

    Roč. 69, č. 3 (2017), s. 133-146 ISSN 0925-2738 R&D Projects: GA ČR GA13-16842S; GA MŠk(CZ) LO1304 Institutional support: RVO:61388963 ; RVO:61388971 ; RVO:68081715 Keywords : nuclear magnetic resonance * relaxation * non-uniform sampling * intrinsically disordered proteins Subject RIV: CB - Analytical Chemistry, Separation; EE - Microbiology, Virology (MBU-M); CB - Analytical Chemistry, Separation (UIACH-O) OBOR OECD: Analytical chemistry; Microbiology (MBU-M); Analytical chemistry (UIACH-O) Impact factor: 2.410, year: 2016

  3. Non-resonant triple alpha reaction rate at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, T.; Tamii, A.; Aoi, N.; Fujita, H.; Hashimoto, T.; Miki, K.; Ogata, K. [Research Center for Nuclear Physics, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Carter, J.; Donaldson, L.; Sideras-Haddad, E. [Schools of Physics, University of Witwatersrand, Johannesburg 2050 (South Africa); Furuno, T.; Kawabata, T. [Departments of Physics, Kyoto University, Sakyo, Kyoto, 606-8502 (Japan); Kamimura, M. [RIKEN Nishina Center, Wako, Saitama, 351-0198 (Japan); Nemulodi, F.; Neveling, R.; Smit, F. D.; Swarts, C. [iThemba Laboratory for Accelerator Based Sciences Somerset, West, 7129 (South Africa)

    2014-05-02

    Our experimental goal is to study the non-resonant triple alpha reaction rate at low temperture (T < 10{sup 8} K). The {sup 13}C(p,d) reaction at 66 MeV has been used to probe the alpha-unbound continuum state in {sup 12}C just below the 2{sup nd} 0{sup +} state at 7.65 MeV. The transition strength to the continuum state is predicted to be sensitive to the non-resonant triple alpha reaction rate. The experiment has been performed at iThemba LABS. We report the present status of the experiment.

  4. Triple Giant Resonance Excitations: A Microscopic Approach

    International Nuclear Information System (INIS)

    Lanza, E.G.; Andres, M.V.; Catara, F.; Chomaz, Ph.; Fallot, M.; Scarpaci, J.A.

    2007-01-01

    We present, for the first time, microscopic calculations of inelastic cross sections of the triple excitation of giant resonances induced by heavy ion probes. We start from a microscopic approach based on RPA. The mixing of three-phonon states among themselves and with two- and one-phonon states is considered within a boson expansion with Pauli corrections. In this way we go beyond the standard harmonic approximations and get anharmonic excitation spectra. At the same time we also introduce non-linearities in the external field. The calculations are done by solving semiclassical coupled channel equations, the channels being superpositions of one-, two- and three-phonon states. Previous calculations for the Double Giant Resonance excitation show good agreement with experimental cross sections. The inclusion of the three phonon components confirms the previous results for the DGR and produces a strong increase in the Triple GR energy region

  5. Normalization for triple-target microarray experiments

    Directory of Open Access Journals (Sweden)

    Magniette Frederic

    2008-04-01

    Full Text Available Abstract Background Most microarray studies are made using labelling with one or two dyes which allows the hybridization of one or two samples on the same slide. In such experiments, the most frequently used dyes are Cy3 and Cy5. Recent improvements in the technology (dye-labelling, scanner and, image analysis allow hybridization up to four samples simultaneously. The two additional dyes are Alexa488 and Alexa494. The triple-target or four-target technology is very promising, since it allows more flexibility in the design of experiments, an increase in the statistical power when comparing gene expressions induced by different conditions and a scaled down number of slides. However, there have been few methods proposed for statistical analysis of such data. Moreover the lowess correction of the global dye effect is available for only two-color experiments, and even if its application can be derived, it does not allow simultaneous correction of the raw data. Results We propose a two-step normalization procedure for triple-target experiments. First the dye bleeding is evaluated and corrected if necessary. Then the signal in each channel is normalized using a generalized lowess procedure to correct a global dye bias. The normalization procedure is validated using triple-self experiments and by comparing the results of triple-target and two-color experiments. Although the focus is on triple-target microarrays, the proposed method can be used to normalize p differently labelled targets co-hybridized on a same array, for any value of p greater than 2. Conclusion The proposed normalization procedure is effective: the technical biases are reduced, the number of false positives is under control in the analysis of differentially expressed genes, and the triple-target experiments are more powerful than the corresponding two-color experiments. There is room for improving the microarray experiments by simultaneously hybridizing more than two samples.

  6. Development of 600 kV triple resonance pulse transformer.

    Science.gov (United States)

    Li, Mingjia; Zhang, Faqiang; Liang, Chuan; Xu, Zhou

    2015-06-01

    In this paper, a triple-resonance pulse transformer based on an air-core transformer is introduced. The voltage across the high-voltage winding of the air-core transformer is significantly less than the output voltage; instead, the full output voltage appears across the tuning inductor. The maximum ratio of peak load voltage to peak transformer voltage is 2.77 in theory. By analyzing pulse transformer's lossless circuit, the analytical expression for the output voltage and the characteristic equation of the triple-resonance circuit are presented. Design method for the triple-resonance pulse transformer (iterated simulation method) is presented, and a triple-resonance pulse transformer is developed based on the existing air-core transformer. The experimental results indicate that the maximum ratio of peak voltage across the load to peak voltage across the high-voltage winding of the air-core transformer is approximately 2.0 and the peak output voltage of the triple-resonance pulse transformer is approximately 600 kV.

  7. Triple resonance experiments for the simultaneous correlation of H6/H5 and exchangeable protons of pyrimidine nucleotides in 13C,15N-labeled RNA applicable to larger RNA molecules

    International Nuclear Information System (INIS)

    Woehnert, Jens; Goerlach, Matthias; Schwalbe, Harald

    2003-01-01

    Triple-resonance two-dimensional H6/H5(C4N)H and C6/C5(C4N)H experiments are described that provide through-bond H6/H5 or C6/C5 to imino/amino correlations in pyrimidine bases in 13 C, 15 N-labeled RNA. The experiments simultaneously transfer H6/H5 magnetization by an INEPT step to the C6/C5 nuclei and by homonuclear CC- and heteronuclear CN-TOCSY steps via the intervening C4 nucleus to the N3/N4 nuclei and then by a reverse INEPT step to the imino/amino hydrogens. The sensitivity of these experiments is high as demonstrated using a 30-nucleotide pyrimidine rich RNA at a concentration of 0.9 mM at temperatures of 10 deg. C and 25 deg. C. This indicates the general applicability of the experiments and the possibility to obtain correlations for imino resonances in non-canonical regions of the target RNA

  8. Electrically protected resonant exchange qubits in triple quantum dots.

    Science.gov (United States)

    Taylor, J M; Srinivasa, V; Medford, J

    2013-08-02

    We present a modulated microwave approach for quantum computing with qubits comprising three spins in a triple quantum dot. This approach includes single- and two-qubit gates that are protected against low-frequency electrical noise, due to an operating point with a narrowband response to high frequency electric fields. Furthermore, existing double quantum dot advances, including robust preparation and measurement via spin-to-charge conversion, are immediately applicable to the new qubit. Finally, the electric dipole terms implicit in the high frequency coupling enable strong coupling with superconducting microwave resonators, leading to more robust two-qubit gates.

  9. Electron spin resonance (ESR), electron nuclear double resonance (ENDOR) and general triple resonance of irradiated biocarbonates

    International Nuclear Information System (INIS)

    Schramm, D.U.; Rossi, A.M.

    1996-01-01

    Several irradiated bicarbonates were studied by magnetic resonance techniques. Seven paramagnetic species, attributed to CO 2 - , SO 2 - and SO 3 - were identified. Comparison between radiation induced defects in bioaragonites and aragonite single-crystals show that isotropic and orthorhombic CO 2 - centers with broad line spectra are not produced in the latter samples. Vibrational and rotational properties of isotropic CO 2 - centers were studied from low temperature Q-band spectras. Vibrational frequency is determined from the 13 CO 2 - hyperfine spectrum and yielded ν 1.54 x 10 13 s -1 . The correlation time for isotropic CO 2 - , τc) = 1.2 x 10 -11 s (T = 300 K0, is typical of radicals rotating in liquids. ENDOR and General Triple spectroscopy show that orthorhombic CO 2 - centres are surrounded by water molecules located in the second nearest CO 2 2- sites at 5.14, 5.35 and 6.02 A. Water molecules replacing carbonates or as liquid inclusion of growth solution in local crystal imperfections may be responsible for the variety of orthorhombic and isotropic CO 2 - species, respectively. (author)

  10. Polarization Insensitivity in Double-Split Ring and Triple-Split Ring Terahertz Resonators

    International Nuclear Information System (INIS)

    Wu Qian-Nan; Lan Feng; Tang Xiao-Pin; Yang Zi-Qiang

    2015-01-01

    A modified double-split ring resonator and a modified triple-split ring resonator, which offer polarization-insensitive performance, are investigated, designed and fabricated. By displacing the two gaps of the conventional double-split ring resonator away from the center, the second resonant frequency for the 0° polarized wave and the resonant frequency for the 90° polarized wave become increasingly close to each other until they are finally identical. Theoretical and experimental results show that the modified double-split ring resonator and the modified triple-split ring resonator are insensitive to different polarized waves and show strong resonant frequency dips near 433 and 444 GHz, respectively. The results of this work suggest new opportunities for the investigation and design of polarization-dependent terahertz devices based on split ring resonators. (paper)

  11. Characterization of bundled and individual triple-walled carbon nanotubes by resonant Raman spectroscopy.

    Science.gov (United States)

    Hirschmann, Thomas Ch; Araujo, Paulo T; Muramatsu, Hiroyuki; Zhang, Xu; Nielsch, Kornelius; Kim, Yoong Ahm; Dresselhaus, Mildred S

    2013-03-26

    The optical characterization of bundled and individual triple-walled carbon nanotubes was studied for the first time in detail by using resonant Raman spectroscopy. In our approach, the outer tube of a triple-walled carbon nanotube system protects the two inner tubes (or equivalently the inner double-walled carbon nanotube) from external environment interactions making them a partially isolated system. Following the spectral changes and line-widths of the radial breathing modes and G-band by performing laser energy dependent Raman spectroscopy, it is possible to extract important information as regards to the electronic and vibrational properties, tube diameters, wall-to-wall distances, radial breathing mode, and G-band resonance evolutions as well as high-curvature intertube interactions in isolated double- and triple-walled carbon nanotube systems.

  12. Microstrip resonators for electron paramagnetic resonance experiments

    Science.gov (United States)

    Torrezan, A. C.; Mayer Alegre, T. P.; Medeiros-Ribeiro, G.

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5×1010 spins/GHz1/2 despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  13. Microstrip resonators for electron paramagnetic resonance experiments.

    Science.gov (United States)

    Torrezan, A C; Mayer Alegre, T P; Medeiros-Ribeiro, G

    2009-07-01

    In this article we evaluate the performance of an electron paramagnetic resonance (EPR) setup using a microstrip resonator (MR). The design and characterization of the resonator are described and parameters of importance to EPR and spin manipulation are examined, including cavity quality factor, filling factor, and microwave magnetic field in the sample region. Simulated microwave electric and magnetic field distributions in the resonator are also presented and compared with qualitative measurements of the field distribution obtained by a perturbation technique. Based on EPR experiments carried out with a standard marker at room temperature and a MR resonating at 8.17 GHz, the minimum detectable number of spins was found to be 5 x 10(10) spins/GHz(1/2) despite the low MR unloaded quality factor Q0=60. The functionality of the EPR setup was further evaluated at low temperature, where the spin resonance of Cr dopants present in a GaAs wafer was detected at 2.3 K. The design and characterization of a more versatile MR targeting an improved EPR sensitivity and featuring an integrated biasing circuit for the study of samples that require an electrical contact are also discussed.

  14. Compact Microstrip Triple-Mode Bandpass Filters Using Dual-Stub-Loaded Spiral Resonators

    Directory of Open Access Journals (Sweden)

    K. D. Xu

    2017-04-01

    Full Text Available Two new microstrip triple-mode resonators loaded with T-shaped open stubs using axially and centrally symmetric spiral structures, respectively, are presented. Spiraled for circuit size reduction, these two half-wavelength resonators can both generate three resonant modes over a wide frequency band by loading two T-stubs with different lengths. Due to the structural symmetry, they can be analyzed by odd- and even-mode method. To validate the design concept, two compact bandpass filters (BPFs using these two novel resonators with center frequencies of 1.76 GHz and 2.44 GHz for the GSM1800 and WLAN/Zigbee applications, respectively, have been designed, fabricated and tested. The center frequencies and bandwidths can be tunable through the analysis of resonant frequency responses, fractional bandwidths and external quality factor versus the resonator parameters. The final measured results have achieved good consistence with the simulations of these two BPFs.

  15. EPR dating CO2- sites in tooth enamel apatites by ENDOR and triple resonance

    International Nuclear Information System (INIS)

    Vugman, N.V.; Rigby, S.E.J.

    1995-01-01

    In this work we combine electron paramagnetic resonance (EPR), high-resolution electron nucleus double resonance (ENDOR) and general triple resonance (GTR) spectroscopies, to study the local environment of the CO 2 - groups created by ionizing radiation in fossil tooth enamel. We demonstrate that the CO 2 - groups occupy slightly modified phosphate sites in the hydroxyapatite lattice. In quaternary shark enamel we found these groups to be interacting with water molecules in the apatite channels. The absence of water molecules as first neighbours in mammalian samples indicate, however, that these molecules are not significantly responsible for the stabilization of CO 2 - dating centers in enamel. (author)

  16. Nonlinear elasticity in resonance experiments

    Science.gov (United States)

    Li, Xun; Sens-Schönfelder, Christoph; Snieder, Roel

    2018-04-01

    Resonant bar experiments have revealed that dynamic deformation induces nonlinearity in rocks. These experiments produce resonance curves that represent the response amplitude as a function of the driving frequency. We propose a model to reproduce the resonance curves with observed features that include (a) the log-time recovery of the resonant frequency after the deformation ends (slow dynamics), (b) the asymmetry in the direction of the driving frequency, (c) the difference between resonance curves with the driving frequency that is swept upward and downward, and (d) the presence of a "cliff" segment to the left of the resonant peak under the condition of strong nonlinearity. The model is based on a feedback cycle where the effect of softening (nonlinearity) feeds back to the deformation. This model provides a unified interpretation of both the nonlinearity and slow dynamics in resonance experiments. We further show that the asymmetry of the resonance curve is caused by the softening, which is documented by the decrease of the resonant frequency during the deformation; the cliff segment of the resonance curve is linked to a bifurcation that involves a steep change of the response amplitude when the driving frequency is changed. With weak nonlinearity, the difference between the upward- and downward-sweeping curves depends on slow dynamics; a sufficiently slow frequency sweep eliminates this up-down difference. With strong nonlinearity, the up-down difference results from both the slow dynamics and bifurcation; however, the presence of the bifurcation maintains the respective part of the up-down difference, regardless of the sweep rate.

  17. Nonlinear properties of double and triple barrier resonant tunneling structures in the sub-THz range

    International Nuclear Information System (INIS)

    Karuzskij, A.L.; Perestoronin, A.V.; Volchkov, N.A.

    2012-01-01

    The high-frequency nonlinear properties of GaAs/AlAs resonant tunneling diode (RTD) nanostructures and perspectives of implementation of the quantum regime of amplification in such structures, which is especially efficient in the range of sub-THz and THz ranges, are investigated. It is shown that in a triple barrier RTD the symmetry between the processes of amplification and dissipation can be avoided because of the interaction of an electromagnetic wave with both of resonant states in two quantum wells, that results in the significant growth of an RTD efficiency [ru

  18. Complementary Split Ring Resonator Based Triple Band Microstrip Antenna for WLAN/WiMAX Applications

    Directory of Open Access Journals (Sweden)

    W. Ali

    2017-04-01

    Full Text Available A new simple design of a triple-band microstrip antenna using metamaterial concept is presented in this paper. Multi-unit cell was the key of the multi resonance response that was obtained by etching two circular and one rectangular split ring resonator (SRR unit cells in the ground plane of a conventional patch operating at 3.56 GHz .The circular unit cells are resonating at 5.6 GHz for the upper band of Wi-MAX, while the rectangular cell is designed to produce a resonance at 2.45 GHz for the lower band of WLAN. WiMAX's/WLAN's operating bands are covered by the triple resonances which are achieved by the proposed antenna with quite enhanced performance. A detailed parametric study of the placement for the metamaterial unit cells is introduced and the most suitable positions are chosen to be the place of the unit cells for enhanced performance. A good consistency between simulation and measurement confirms the ability of the proposed antenna to achieve an improved gain at the three different frequencies.

  19. Heteronuclear cross-polarization in multinuclear multidimensional NMR: Prospects for triple-resonance CP

    Energy Technology Data Exchange (ETDEWEB)

    Majumdar, A.; Zuiderweg, E.R.P. [Univ. of Michigan, Ann Arbor, MI (United States)

    1994-12-01

    Heteronuclear multiple-pulse-based Cross Polarization (HECP) between scalar coupled spins is gaining an important role in high-resolution multidimensional NMR of isotopically labeled biomolecules, especially in experiments involving net magnetization transfer. It has generally been observed that in these situations, the performance of HECP is superior to that of INEPT-based sequences. In particular, HECP-based three-dimensional HCCH spectroscopy is more efficient than the INEPT version of the same experiment. Differences in sensitivity have been intuitively attributed to relaxation effects and technical factors such as radiofrequency (rf) inhomogeneity We present theoretical analyses and computer simulations to probe the effects of these factors. Relaxation effects were treated phenomenologically; we found that relaxation differences are relatively small (up to 25%) between pulsed-free-precession (INEPT) and HECP-although always in favor of HECP. We explored the rf effects by employing a Gaussian distribution of rf amplitude over sample volume. We found that inhomogeneity effects significantly favor HECP over INEPT, especially under conditions of {open_quotes}matched {close_quotes} inhomogeneity in the two rf coils. The differences in favor of HECP indicate that an extension of HECP to triple resonance experiments (TRCP) in I -> S -> Q net transfers might yield better results relative to analogous INEPT-based net transfers. We theoretically analyze the possibilities of TRCP and find that transfer functions are critically dependent on the ratio J{sub IS}/J{sub SQ}. When J{sub IS} equals J{sub SQ}, we find that 100% transfer is possible for truly simultaneous TRCP and this transfer is obtained in a time 1.41 /J. The TRCP time requirement compares favorably with optimally concatenated INEPT-transfers, where net transfer I -> S -> Q is complete at 1.5 /J.

  20. Stochastic resonance in a delayed triple-well potential driven by correlated noises.

    Science.gov (United States)

    Xu, Pengfei; Jin, Yanfei; Xiao, Shaomin

    2017-11-01

    In this paper, we investigate stochastic resonance (SR) in a delayed triple-well potential subject to correlated noises and a harmonic signal. The stationary probability density, together with the response amplitude of the system, is obtained by using the small time delay approximation. It is found that the time delay, noise intensities, and the cross-correlation between noises can induce the occurrence of the transition. Moreover, the appropriate choice of noise intensities and time delay can improve the output of the system, enhance the SR effect, and lead to the phenomenon of noise enhanced stability. Especially, the stochastic multi-resonance phenomenon is observed when the multiplicative and additive noises are correlated. Finally, the theoretical results are well verified through numerical simulations.

  1. Multi-band circular polarizer based on a twisted triple split-ring resonator

    International Nuclear Information System (INIS)

    Wu Song; Huang Xiao-Jun; Yang He-Lin; Xiao Bo-Xun; Jin Yan

    2014-01-01

    A multi-band circular polarizer using a twisted triple split-ring resonator (TSRR) is presented and studied numerically and experimentally. At four distinct resonant frequencies, the incident linearly polarized wave can be transformed into left/right-handed circularly polarized waves. Numerical simulation results show that a y-polarized wave can be converted into a right-handed circularly polarized wave at 5.738 GHz and 9.218 GHz, while a left-handed circularly polarized wave is produced at 7.292 GHz and 10.118 GHz. The experimental results are in agreement with the numerical results. The surface current distributions are investigated to illustrate the polarization transformation mechanism. Furthermore, the influences of the structure parameters of the circular polarizer on transmission spectra are discussed as well. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  2. Polarization spectroscopy of the sodium dimer utilizing a triple-resonance technique in the presence of argon

    Science.gov (United States)

    Arndt, Phillip; Horton, Timothy; McFarland, Jacob; Bayram, Burcin; Miami University Spectroscopy Team

    2015-05-01

    The collisional dynamics of molecular sodium in the 61Σg electronic state is under investigation using a triple resonance technique in the presence of argon. A continuous wave ring dye laser is used to populate specific rovibrational levels of the A1Σu electronic state. A pump-probe technique is then employed where the pump laser populates the 61Σg state, and the probe laser dumps the population to the B1Σu state. From this level, fluorescence is detected as the system decays to the X1Σg state. We measure the polarization of this signal in the presence of various argon pressures. We will present our current work as well as the processes involved in the experiment. Financial support from the National Science Foundation (Grant No. NSF-PHY-1309571) is gratefully acknowledged.

  3. Intrinsic current oscillations in an asymmetric triple-barrier resonant tunnelling diode

    International Nuclear Information System (INIS)

    Wójcik, P; Spisak, B J; Wołoszyn, M; Adamowski, J

    2010-01-01

    The electronic transport characteristics of an asymmetric triple-barrier resonant tunnelling diode are calculated by the time-dependent Wigner–Poisson method. The intrinsic current oscillations are found in two separate bias voltage ranges. The first one is located below the resonant current peak, and the second lies in the negative differential resistance region. We provide the explanation of the current density oscillations in these two separate bias voltage ranges based on the analysis of the self-consistent potential profiles and changes of electron density. We have shown that two different formation mechanisms are responsible for the current density oscillations in these two bias voltage ranges. In the bias voltage range below the resonant current peak in the current–voltage characteristics, the current density oscillations are caused by the coupling between quasi-bound states in the left and right quantum wells. On the other hand, the current density oscillations in the negative differential resistance region result from the coupling between quasi-bound states in the left quantum well and the quantum well formed in the region of the left contact

  4. Impact of depth and location of the wells on vibrational resonance in a triple-well system

    Science.gov (United States)

    Chen, Zhijuan; Ning, Lijuan

    2018-04-01

    The effect of depth and location of a triple-well potential on vibrational resonance is investigated in a quintic oscillator driven by a low-frequency force and a high-frequency force. The values of low-frequency ω and amplitude g of the high-frequency force at which vibrational resonance occurs are derived both numerically and theoretically. It is found that: as ω varies, at most one resonance takes place and the response amplitude at resonance depends on the depth and the location of the potential wells. When g is altered, the depth and location of wells can control the number of resonances, resulting in two, three and four resonances. The system parameters can be adjusted by controlling the depth and position of the wells to achieve optimum vibrational resonance. Furthermore, the changes induced by these two quantities in the tristable system are found to be richer than those induced in bistable systems.

  5. New Circuit QED system based on Triple-leg Stripline Resonator.

    Science.gov (United States)

    Kim, Dongmin; Moon, Kyungsun

    Conventional circuit QED system consists of a qubit located inside a linear stripline resonator, which has successfully demonstrated a strong coupling between a single photon and a qubit. Here we present a new circuit QED system, where the qubit is coupled to triple-leg stripline resonator (TSR). We have shown that TSR supports two-fold degenerate photon modes among others. By coupling them to a single qubit, we have obtained the dressed states of a coupled system of a single qubit and two-fold degenerate photon modes. By locating two qubits at two legs of TSR, we have studied a potential two-bit gate operation (e.g., CNOT gate) of the system. We will discuss the main advantage of utilizing two-fold degenerate photon modes This work is partially supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (NRF-2016R1D1A1B01013756).

  6. Validity - a matter of resonant experience

    DEFF Research Database (Denmark)

    Revsbæk, Line

    This paper is about doing interview analysis drawing on researcher’s own lived experience concerning the question of inquiry. The paper exemplifies analyzing case study participants’ experience from the resonant experience of researcher’s own life evoked while listening to recorded interview...... across researcher’s past experience from the case study and her own life. The autobiographic way of analyzing conventional interview material is exemplified with a case of a junior researcher researching newcomer innovation of others, drawing on her own experience of being newcomer in work community...... entry processes. The validity of doing interview analysis drawing on the resonant experience of researcher is argued from a pragmatist perspective....

  7. Logical stochastic resonance in triple-well potential systems driven by colored noise.

    Science.gov (United States)

    Zhang, Huiqing; Xu, Yong; Xu, Wei; Li, Xiuchun

    2012-12-01

    In this work, the logic stochastic resonance (LSR) phenomenon in a class of stochastic triple-well potential systems is investigated. Approximate Fokker-Planck equation is first obtained by using decoupling approximation. Then, we show that LSR can be successfully induced by additive or multiplicative Gaussian colored noise in some cases. In the absence of internal noise, LSR implementation seems impossible for a = 0 (The parameter a characterizes the depth of the potential well) since the two side wells are so deep that the particle cannot hop over the barrier into the middle well when the input signal is 0. With the increasing of a, the optimal noise band to yield flexible logic gates appears and moves to higher level of noise as the correlation time of noise increases. Compared with the Gaussian white noise, the reliable region in the parameter plane of potential depth parameter a and additive noise strength D first expands and then shrinks with increasing noise color. Furthermore, the effects of multiplicative Gaussian colored noise on LSR are investigated. It was found that the flexible and reliable logic behavior can be yielded for a = 0 due to the fact that the multiplicative Gaussian colored noise strongly affects the shape of the potential function. With the increasing of a, i.e., a = 0.25, multiplicative Gaussian white noise cannot yield desired logic behavior. Fortunately, LSR can also be expected by adjusting the correlation time of Gaussian colored noise. It can also be observed that the reliable region in the parameter plane of potential depth parameter a and multiplicative noise strength Q is small for the case of Gaussian white noise and it becomes larger with the increasing of noise color.

  8. Radiative widths of resonances (experiments)

    International Nuclear Information System (INIS)

    Gidal, G.

    1988-07-01

    After a hiatus of several years, this conference brings us considerable new data on resonance production in photon photon interactions. I will first discuss the contributions concerning the tensor, pseudoscalar and scalar mesons, then review the current status of the (c/ovr string/c /eta//sub c/) and finally summarize the exciting new results concerning the spin 1 mesons. 40 refs., 21 figs., 7 tabs

  9. ACCELERATING COMPACT OBJECT MERGERS IN TRIPLE SYSTEMS WITH THE KOZAI RESONANCE: A MECHANISM FOR 'PROMPT' TYPE Ia SUPERNOVAE, GAMMA-RAY BURSTS, AND OTHER EXOTICA

    International Nuclear Information System (INIS)

    Thompson, Todd A.

    2011-01-01

    White dwarf-white dwarf (WD-WD) and neutron star-neutron star (NS-NS) mergers may produce Type Ia supernovae and gamma-ray bursts (GRBs), respectively. A general problem is how to produce binaries with semi-major axes small enough to merge in significantly less than the Hubble time (t H ), and thus accommodate the observation that these events closely follow episodes of star formation. I explore the possibility that such systems are not binaries at all, but actually coeval, or dynamical formed, triple systems. The tertiary induces Kozai oscillations in the inner binary, driving it to high eccentricity, and reducing its gravitational wave (GW) merger timescale. This effect significantly increases the allowed range of binary period P such that the merger time is t merge H . In principle, Chandrasekhar-mass binaries with P ∼ 300 days can merge in ∼ H if they contain a prograde solar-mass tertiary at high enough inclination. For retrograde tertiaries, the maximum P such that t merge ∼ H is yet larger. In contrast, P ∼< 0.3 days is required in the absence of a tertiary. I discuss implications of these findings for the production of transients formed via compact object binary mergers. Based on the statistics of solar-type binaries, I argue that many such binaries should be in triple systems affected by the Kozai resonance. If true, expectations for the mHz GW signal from individual sources, the diffuse background, and the foreground for GW experiments like LISA are modified. This work motivates future studies of triples systems of A, B, and O stars, and new types of searches for WD-WD binaries in triple systems.

  10. OPTIMAL EXPERIMENT DESIGN FOR MAGNETIC RESONANCE FINGERPRINTING

    OpenAIRE

    Zhao, Bo; Haldar, Justin P.; Setsompop, Kawin; Wald, Lawrence L.

    2016-01-01

    Magnetic resonance (MR) fingerprinting is an emerging quantitative MR imaging technique that simultaneously acquires multiple tissue parameters in an efficient experiment. In this work, we present an estimation-theoretic framework to evaluate and design MR fingerprinting experiments. More specifically, we derive the Cram��r-Rao bound (CRB), a lower bound on the covariance of any unbiased estimator, to characterize parameter estimation for MR fingerprinting. We then formulate an optimal experi...

  11. Resonance Project; Music from the ATLAS Experiment

    CERN Multimedia

    Claudia Marcelloni

    2010-01-01

    The ATLAS Collaboration comprises physicists, engineers, technicians and support staff from 38 countries who have come together at CERN to build and run one of the largest, most complex scientific experiments known to mankind. Drawn together by our common love of science, many of us are also passionate about music. In October 2008, we marked the completion of the ATLAS detector construction with a series of live performances, and thus was born the idea for Resonance. The recording experience was exciting and enjoyable for all of us, many of whom had never entered a studio before. Resonance is a double CD featuring a variety of musical styles from classical to heavy metal. It also includes a DVD with footage of the recording sessions and interviews with some of the musicians. For more information go to www.atlas-resonance.ch

  12. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Experiments to Further the Understanding of the Triple-Alpha Process in Hot Astrophysical Scenarios

    International Nuclear Information System (INIS)

    Patel, N. R.; Greife, U.; Rehm, K. E.; Greene, J.; Henderson, D.; Jiang, C. L.; Kay, B. P.; Lee, H. Y.; Pardo, R.; Teh, K.; Deibel, C. M.; Notani, M.; Marley, S. T.; Tang, X. D.

    2009-01-01

    In astrophysics, the first excited 0 + state of 12 C at 7.654 MeV (Hoyle state) is the most important in the triple-α process for carbon nucleosynthesis. In explosive scenarios like supernovae, where temperatures of several 10 9 K are achieved, the interference of the Hoyle state with the second 0 + state located at 10.3 MeV in 12 C becomes significant. The recent NACRE compilation of astrophysical reaction rates assumes a 2 + resonance at 9.1 MeV for which no experimental evidence exists. Thus, it is critical to explore in more detail the 7-10 MeV excitation energy region, especially the minimum between the two 0 + resonances for carbon nucleosynthesis. The states in 12 C were populated through the β-decay of 12 B and 12 N produced at the ATLAS (Argonne Tandem Linac Accelerator System) in-flight facility. The decay of 12 C into three alphas is detected in a Frisch grid twin ionization chamber, acting as a low-threshold calorimeter. This minimizes the effects of β-summing and allowed us to investigate the minimum above the Hoyle state with much higher accuracy than previously possible. A detailed data analysis will include an R-matrix fit to determine an upper limit on the 2 + resonance width.

  14. A UWB Band-Pass Antenna with Triple-Notched Band Using Common Direction Rectangular Complementary Split-Ring Resonators

    Directory of Open Access Journals (Sweden)

    Bo Yan

    2013-01-01

    Full Text Available A novel ultrawideband (UWB antenna which has a triple-band notch function is presented. The proposed antenna can block interfering signals from C-band satellite communication systems, IEEE802.11a, and HIPERLAN/2 WLAN systems for example. The antenna is excited by using novel common direction rectangular complementary split-ring resonators (CSRR fabricated on radiating patch of the dielectric substrate with coplanar waveguide (CPW feed strip line. The voltage standing wave ratio (VSWR of the proposed antenna is less than 2.0 in the frequency band from 2.8 to 12 GHz, while showing a very sharp band-rejection performance at 3.9 GHz, 5.2 GHz, and 5.9 GHz. The measurement results show that the proposed antenna provides good omnidirectional field pattern over its whole frequency band excluding the rejected band, which is suitable for UWB applications.

  15. A new assay format for NF-kappaB based on a DNA triple helix and a fluorescence resonance energy transfer.

    Science.gov (United States)

    Altevogt, Dominik; Hrenn, Andrea; Kern, Claudia; Clima, Lilia; Bannwarth, Willi; Merfort, Irmgard

    2009-10-07

    Herein we report a feasibility study for a new concept to detect DNA binding protein NF-kappaB based on a DNA triple helix formation in combination with a fluorescence resonance energy transfer (FRET). The new principle avoids expensive antibodies and radioactivity and might have implications for assays of other DNA binding proteins.

  16. Optimal experiment design for magnetic resonance fingerprinting.

    Science.gov (United States)

    Bo Zhao; Haldar, Justin P; Setsompop, Kawin; Wald, Lawrence L

    2016-08-01

    Magnetic resonance (MR) fingerprinting is an emerging quantitative MR imaging technique that simultaneously acquires multiple tissue parameters in an efficient experiment. In this work, we present an estimation-theoretic framework to evaluate and design MR fingerprinting experiments. More specifically, we derive the Cramér-Rao bound (CRB), a lower bound on the covariance of any unbiased estimator, to characterize parameter estimation for MR fingerprinting. We then formulate an optimal experiment design problem based on the CRB to choose a set of acquisition parameters (e.g., flip angles and/or repetition times) that maximizes the signal-to-noise ratio efficiency of the resulting experiment. The utility of the proposed approach is validated by numerical studies. Representative results demonstrate that the optimized experiments allow for substantial reduction in the length of an MR fingerprinting acquisition, and substantial improvement in parameter estimation performance.

  17. Resonant island divertor experiments on text

    International Nuclear Information System (INIS)

    deGrassie, J.S.; Evans, T.E.; Jackson, G.L.

    1988-09-01

    The first experimental tests of the resonant island divertor (RID) concept have been carried out on the Texas Experimental Tokamak (TEXT). Modular perturbation coils produce static resonant magnetic fields at the tokamak boundary. The resulting magnetic islands are used to guide heat and particle fluxes around a small scoop limiter head. An enhancement in the limiter collection efficiency over the nonisland operation, as evidenced by enhanced neutral density within the limiter head, of up to a factor of 4 is obtained. This enhancement is larger than one would expect given the measured magnitude of the cross-field particle transport in TEXT. It is proposed that electrostatic perturbations occur which enhance the ion convection rate around the islands. Preliminary experiments utilizing electron cyclotron heating (ECH) in conjunction with RID operation have also have been performed. 6 refs., 3 figs

  18. Development of a system for simultaneously generating triple extreme conditions for neutron scattering experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ichimura, Shigeju [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-10-01

    We have developed new system available for controlling sample environment during the neutron scattering experiments. The system can simultaneously generate triple extreme conditions of low temperature, high magnetic field and high pressure. The system consists of : (1) a liquid-helium cryostat which enables the sample temperature range of 1.7 K to 200 K, (2) a superconducting magnet providing a vertical field up to 5 Tesla with antisymmetric split-coil geometry for polarized-beam experiments, and (3) a non-magnetic clamping high-pressure cell designed with the aim of generating hydrostatic pressure up to 2.5 Gpa. In the workshop, we will report the outline of the system and some results of performance tests using the system at JRR-3M of JAERI. (author)

  19. Wakeless triple soliton accelerator

    International Nuclear Information System (INIS)

    Mima, K.; Ohsuga, T.; Takabe, H.; Nishihara, K.; Tajima, T.; Zaidman, E.; Horton, W.

    1986-09-01

    We introduce and analyze the concept of a wakeless triple soliton accelerator in a plasma fiber. Under appropriate conditions the triple soliton with two electromagnetic and one electrostatic waves in the beat-wave resonance propagates with velocity c leaving no plasma wake behind, while the phase velocity of the electrostatic wave is made also c in the fiber

  20. Impact of the depth of the wells and multifractal analysis on stochastic resonance in a triple-well system

    International Nuclear Information System (INIS)

    Arathi, S; Rajasekar, S

    2011-01-01

    We analyze the stochastic resonance in a symmetric triple-well system with the depths of the wells being different. The system is subjected to a weak periodic force and Gaussian white noise with strength D. We show that the optimum value of noise intensity (D MAX ) is minimum, while the signal-to-noise ratio is maximum when the ratio (R) of the depths of the middle and side wells is 1. At D MAX , the particle enters the middle well twice during every period of the external periodic force. When the depths of the three wells are equal (R=1), the mean residence time (T MR ) in each well is T/4, where T is the period of the driving force. T MR varies with parameter R; however, periodicity in switching is observed at D MAX for any value of R. The generalized dimensions D q decrease with an increase in noise intensity D, reach a minimum at D=D MAX and then increase for all values of R. The α-f(α) spectrum is always of incomplete concave shape with f(α min )=0, while f(α max )≠0 at any value of D and, moreover, the maximum value of α is minimum at D=D MAX .

  1. Resonant electronic transport through a triple quantum-dot with Λ-type level structure under dual radiation fields

    International Nuclear Information System (INIS)

    Guan, Chun; Xing, Yunhui; Zhang, Chao; Ma, Zhongshui

    2014-01-01

    Due to quantum interference, light can transmit through dense atomic media, a phenomenon known as electromagnetically induced transparency (EIT). We propose that EIT is not limited to light transmission and there is an electronic analog where resonant transparency in charge transport in an opaque structure can be induced by electromagnetic radiation. A triple-quantum-dots system with Λ-type level structure is generally opaque due to the level in the center dot being significantly higher and therefore hopping from the left dot to the center dot is almost forbidden. We demonstrate that an electromagnetically induced electron transparency (EIET) in charge of transport can indeed occur in the Λ-type system. The direct evidence of EIET is that an electron can travel from the left dot to the right dot, while the center dot apparently becomes invisible. We analyze EIET and the related shot noise in both the zero and strong Coulomb blockade regimes. It is found that the EIET (position, height, and symmetry) can be tuned by several controllable parameters of the radiation fields, such as the Rabi frequencies and detuning frequencies. The result offers a transparency/opaque tuning technique in charge transport using interfering radiation fields

  2. Surgical experience of laparoscopic retroperitoneal triple neurectomy for a patient with chronic neuropathic inguinodynia

    Directory of Open Access Journals (Sweden)

    Masato Narita

    2017-01-01

    Conclusions: Laparoscopic retroperitoneal triple neurectomy is useful for treating refractory neuropathic pain. The diagnosis of neuropathic pain via thorough preoperative assessment is vital for procedure success because the procedure would not be effective for other types of pain.

  3. Numerical-experiment investigation of coalescence of gaseous protogalactic fragments in triple systems

    International Nuclear Information System (INIS)

    Kiseleva, L.G.; Orlov, V.V.

    1988-01-01

    The numerical-experiment approach in the framework of the general gravitational three-body problem has been used to investigate the dynamical evolution of triple systems of gaseous protogalactic fragments. The masses of the fragments are equal, the initial velocities zero. The initial positions were specified by uniform scanning in the region D of all possible initial configurations. Calculations were continued until the first two-body encounter of the fragments. Different values of the fragment radii at this times were considered, namely, r in the interval [0.001, 0.1]d, where d is the mean diameter of the system. It is shown that for such r the pair of gaseous fragments coalesces in the majority of cases (from 50.2% for r = 0.001d to 96.7% for r = 0.1d). The mean specific angular momentum of their relative motion, which becomes spin angular momentum of the coalescence product, is (0.8 +- 1.0)/centered dot/10 29 /root/μl cm 2 sec for the most probable value r = 10l kpc (the masses of the fragments are 5/centered dot/10 10 μM/circled dot/; l and μ are scale factors), this agreeing in order of magnitude with the specific angular momenta of disk galaxies if l, μ /approximately/ 1. For each value of r, a continuous zone of initial configurations corresponding to coalescences is identified in the region D

  4. A new strategy for backbone resonance assignment in large proteins using a MQ-HACACO experiment

    International Nuclear Information System (INIS)

    Pervushin, Konstantin; Eletsky, Alexander

    2003-01-01

    A new strategy of backbone resonance assignment is proposed based on a combination of the most sensitive TROSY-type triple resonance experiments such as TROSY-HNCA and TROSY-HNCO with a new 3D multiple-quantum HACACO experiment. The favourable relaxation properties of the multiple-quantum coherences and signal detection using the 13 C' antiphase coherences optimize the performance of the proposed experiment for application to larger proteins. In addition to the 1 H N , 15 N, 13 C α and 13 C' chemical shifts the 3D multiple-quantum HACACO experiment provides assignment for the 1 H α resonances in contrast to previously proposed experiments for large proteins. The strategy is demonstrated with the 44 kDa uniformly 15 N, 13 C-labeled and fractionally 35% deuterated trimeric B. subtilis Chorismate Mutase measured at 20 deg. C and 9 deg. C. Measurements at the lower temperature indicate that the new strategy can be applied to even larger proteins with molecular weights up to 80 kDa

  5. Resonant neutrino scattering: An impossible experiment?

    International Nuclear Information System (INIS)

    Suzuki, D.; Sumikama, T.; Ogura, M.; Mittig, W.; Shiraki, A.; Ichikawa, Y.; Kimura, H.; Otsu, H.; Sakurai, H.; Nakai, Y.; Hussein, M.S.

    2010-01-01

    The experimental feasibility was investigated for the resonant scattering of monoenergetic neutrinos emitted in the two-body β decay. A simple general formula shows that the resonance cross section can be as large as of the order of 10 -17 cm 2 . The Moessbauer setup using a solid crystal was examined with a focus on the electronic structure of the emitter and the absorber. Based on realistic calculations, we show that interactions of valence electrons in the solid lead to a level broadening of the atomic ground state, which considerably suppresses the resonant scattering of neutrinos.

  6. Resonant experience in emergent events of analysis

    DEFF Research Database (Denmark)

    Revsbæk, Line

    2018-01-01

    Theory, and the traditions of thought available and known to us, give shape to what we are able to notice of our field of inquiry, and so also of our practice of research. Building on G. H. Mead’s Philosophy of the Present (1932), this paper draws attention to ‘emergent events’ of analysis when...... in responsive relating to (case study) others is made generative as a dynamic in and of case study analysis. Using a case of being a newcomer (to research communities) researching newcomer innovation (of others), ‘resonant experience’ is illustrated as a heuristic in interview analysis to simultaneously...

  7. Generation of coherent radiation in vacuum ultra-violet by tripling frequency in continuous supersonic nitrogen free jet: quantitative investigation of resonance phenomena

    International Nuclear Information System (INIS)

    Faucher, Olivier

    1991-01-01

    This research thesis reports experimental studies performed on the generation of a coherent radiation in vacuum ultraviolet (94 nm) by tripling the frequency of an ultraviolet laser focussed within a continuous supersonic free nitrogen jet. After a recall of some general issues related to non-linear optics, the evolution of the non-linear susceptibility and conditions of phase adaptation in supersonic jet have been determined. This allowed a quantitative study of the third harmonic generation for the three following types of conversion: without resonance, with resonance with two photons, and with resonance with three photons. In the first two cases, due to the absence of saturation phenomena, measuring the harmonic signal intensity allows a diagnosis of the non-linear medium internal state to the performed. As far as the third harmonic generation with resonance with three photons is concerned, the use of supersonic free jet properties leads to a perfect understanding of saturation effects by self-absorption which are at the origin of the unusual character of the obtained spectra [fr

  8. Spatiotemporal Stochastic Resonance:Theory and Experiment

    Science.gov (United States)

    Peter, Jung

    1996-03-01

    The amplification of weak periodic signals in bistable or excitable systems via stochastic resonance has been studied intensively over the last years. We are going one step further and ask: Can noise enhance spatiotemporal patterns in excitable media and can this effect be observed in nature? To this end, we are looking at large, two dimensional arrays of coupled excitable elements. Due to the coupling, excitation can propagate through the array in form of nonlinear waves. We observe target waves, rotating spiral waves and other wave forms. If the coupling between the elements is below a critical threshold, any excitational pattern will die out in the absence of noise. Below this threshold, large scale rotating spiral waves - as they are observed above threshold - can be maintained by a proper level of the noise[1]. Furthermore, their geometric features, such as the curvature can be controlled by the homogeneous noise level[2]. If the noise level is too large, break up of spiral waves and collisions with spontaneously nucleated waves yields spiral turbulence. Driving our array with a spatiotemporal pattern, e.g. a rotating spiral wave, we show that for weak coupling the excitational response of the array shows stochastic resonance - an effect we have termed spatiotemporal stochastic resonance. In the last part of the talk I'll make contact with calcium waves, observed in astrocyte cultures and hippocampus slices[3]. A. Cornell-Bell and collaborators[3] have pointed out the role of calcium waves for long-range glial signaling. We demonstrate the similarity of calcium waves with nonlinear waves in noisy excitable media. The noise level in the tissue is characterized by spontaneous activity and can be controlled by applying neuro-transmitter substances[3]. Noise effects in our model are compared with the effect of neuro-transmitters on calcium waves. [1]P. Jung and G. Mayer-Kress, CHAOS 5, 458 (1995). [2]P. Jung and G. Mayer-Kress, Phys. Rev. Lett.62, 2682 (1995). [3

  9. Triple approach for diagnosing breast lesions-experience at a Tertiary Care Hospital

    Directory of Open Access Journals (Sweden)

    Ritu Mehta

    2017-01-01

    Full Text Available Background: Breast lesions are always a diagnostic challenge and range from benign to malignant. Fine-Needle Aspiration Cytology (FNAC is done in patients with breast lesions. However, to get an accurate and diagnostic yield is difficult at times. Aims: The aim of this study is to highlight the role of triple approach in diagnosing breast lesions. Design and Setting: This is an observational prospective study carried out in the Department of Pathology at a tertiary care hospital over 2 years. Materials and Methods: One hundred and fifty cases of breast lump were studied. Clinical findings, imaging findings, and cytology along with histopathological findings were correlated. Results: Cytological findings were benign in 102 out of 107 patients, who were otherwise clinically and radiologically benign. In rest five patients, Breast Imaging Reporting and Data Systems (BIRADS BIRADS II category was given on mammography. In four of these five patients, there was cytological atypia. Biopsy in these four patients showed features of fibroadenoma with mild cytological atypia and one patient showed infiltrating duct carcinoma. Mammography was suggestive of malignant breast lump in 43 patients. In three patients, breast lump was diagnosed as benign on cytological examination. However, histopathological examination confirmed the mammography findings of malignancy. Conclusion: FNAC is a well-established procedure for diagnosing breast lesion but has got many pitfalls. Hence for diagnosis a breast lesion, the triple approach consisting of histopathological examination in addition to mammography and FNAC, should be considered.

  10. The role of triple pelvic osteotomy in therapy of residual hip dysplasia and sequel of AVN: long-term experience.

    Science.gov (United States)

    Dungl, P; Rejholec, M; Chomiak, J; Grill, F

    2007-01-01

    Triple pelvic osteotomy was performed for sequel of DDH including AVN between 1981 and 2002 for 329 patients (351 hips, 280 females, 49 males, average age at surgery 16.5 years, range 9-41 years, follow-up 4-25 years). A small modification of Steel's technique consisting of strictly subperiostal resection of segment from both pubic and ischial bone was used. Average gain of lengthening extremity was 1.8 cm. The average CE angle was improved from 7.8 to 35.5 degrees. Clinical results were evaluated according to Merle d'Aubigne and reflected to the preoperative clinical and radiological findings. There were 146 hip joints in 128 patients (76%) with excellent results in the group of congruent hips without arthrosis. In 182 hips in 178 patients with hip joints with some deformity, limited ROM and decentration, 40% were excellent, 32% good, 23% fair and 5% unsatisfactory results were achieved. The group of decentrated hip joints in young adults in incongruency, limited ROM and sometimes severe arthrosis consisted of 23 monolateral surgeries with 39% unsatisfactory, 39% fair and 22% good results, respectively. No major neurovascular complications were seen. Non-unions were recorded in 19 patients (5.4%), including 2 triple and 2 double non-unions. Based on our long-term experience, we can conclude that triple pelvic osteotomy according to Steel in our modification is a safe method and gives regularly excellent or good results for correction of clinical and radiographic appearance of acetabular dysplasia when there is a proper indication.

  11. Liposomes - experiment of magnetic resonance imaging application

    International Nuclear Information System (INIS)

    Mathieu, S.

    1987-01-01

    Most pharmaceutical research effort with liposomes has been involved with the investigation of their use as drug carriers to particular target organs. Recently there has been a growing interest in liposomes not only as carrier of drugs but as a tool for the introduction of various substances into the human body. In this study, liposome delivery of nitroxyl radicals as NMR contrast agent for improved tissue imaging is experimented in rats [fr

  12. Optimization experiments on the study of giant resonance in nuclei

    International Nuclear Information System (INIS)

    Lyubarskij, G.Ya.; Savitskij, G.A.; Fartushnyj, V.A.; Khazhmuradov, M.A.; Levandovskij, S.P.

    1988-01-01

    Optimum choice of the target exposure to a beam in experiments on the study of giant resonances in nuclei is considered. Optimization is aimed at reducing mean square errors of defined formfactors. Four different optimization quality criteria - variances of four form factor experimental values are considered. Variances resulting form optimization are 1.5-2 times as less as variances in real experiment. The effect of experiment design optimization criterion on form factors determination errors is ascertained. 1 ref.; 3 tabs

  13. Resonator QED experiments with single 40Ca+ ions

    International Nuclear Information System (INIS)

    Lange, B.

    2006-01-01

    Combining an optical resonator with an ion trap provides the possibility for QED experiments with single or few particles interacting with a single mode of the electro-magnetic field (Cavity-QED). In the present setup, fluctuations in the count rate on a time scale below 30 seconds were purely determined by the photon statistics due to finite emission and detection efficiency, whereas a marginal drift of the system was noticeable above 200 seconds. To find methods to increase the efficiency of the photon source, investigations were conducted and experimental improvements of the setup implemented in the frame of this thesis. Damping of the resonator field and coupling of ion and field were considered as the most important factors. To reduce the damping of the resonator field, a resonator with a smaller transmissivity of the output mirror was set up. The linear trap used in the experiment allows for the interaction of multiple ions with the resonator field, so that more than one photon may be emitted per pump pulse. This was investigated in this thesis with two ions coupled to the resonator. The cross correlation of the emitted photons was measured with the Hanbury Brown-Twiss method. (orig.)

  14. Revised rates for the stellar triple-α process from measurement of ¹²C nuclear resonances

    CERN Multimedia

    2005-01-01

    In the centres of stars where the temperature is high enough, three α-particles (helium nuclei) are able to combine to form ¹²C because of a resonant reaction leading to a nuclear excited state (2 pages)

  15. Comparison of Experiment and Simulation of the triple GEM-Based Fast Neutron Detector

    International Nuclear Information System (INIS)

    Wang Xiao-Dong; Luo Wen; Zhang Jun-Wei; Yang He-Run; Duan Li-Min; Lu Chen-Gui; Hu Rong-Jiang; Hu Bi-Tao; Zhang Chun-Hui; Yang Lei; Zhou Jian-Rong; An Lv-Xing

    2015-01-01

    A detector for fast neutrons based on a 10 × 10 cm"2 triple gas electron multiplier (GEM) device is developed and tested. A neutron converter, which is a high density polyethylene (HDPE) layer, is combined with the triple GEM detector cathode and placed inside the detector, in the path of the incident neutrons. The detector is tested by obtaining the energy deposition spectrum with an Am Be neutron source in the Institute of Modern Physics (IMP) at Lanzhou. In the present work we report the results of the tests and compare them with those of simulations. The transport of fast neutrons and their interactions with the different materials in the detector are simulated with the GEANT4 code, to understand the experimental results. The detector displays a clear response to the incident fast neutrons. However, an unexpected disagreement in the energy dependence of the response between the simulated and measured spectra is observed. The neutron sources used in our simulation include deuterium-tritium (DT, 14 MeV), deuterium-deuterium (DD, 2.45 MeV), and Am Be sources. The simulation results also show that among the secondary particles generated by the incident neutron, the main contributions to the total energy deposition are from recoil protons induced in hydrogen-rich HDPE or Kapton (GEM material), and activation photons induced by neutron interaction with Ar atoms. Their contributions account for 90% of the total energy deposition. In addition, the dependence of neutron deposited energy spectrum on the composition of the gas mixture is presented. (paper)

  16. Mechanical Resonators for Quantum Optomechanics Experiments at Room Temperature.

    Science.gov (United States)

    Norte, R A; Moura, J P; Gröblacher, S

    2016-04-08

    All quantum optomechanics experiments to date operate at cryogenic temperatures, imposing severe technical challenges and fundamental constraints. Here, we present a novel design of on-chip mechanical resonators which exhibit fundamental modes with frequencies f and mechanical quality factors Q_{m} sufficient to enter the optomechanical quantum regime at room temperature. We overcome previous limitations by designing ultrathin, high-stress silicon nitride (Si_{3}N_{4}) membranes, with tensile stress in the resonators' clamps close to the ultimate yield strength of the material. By patterning a photonic crystal on the SiN membranes, we observe reflectivities greater than 99%. These on-chip resonators have remarkably low mechanical dissipation, with Q_{m}∼10^{8}, while at the same time exhibiting large reflectivities. This makes them a unique platform for experiments towards the observation of massive quantum behavior at room temperature.

  17. Hafnium Resonance Parameter Analysis Using Neutron Capture and Transmission Experiments

    International Nuclear Information System (INIS)

    MJ Trbovich; DP Barry; RE Slovacck; Y Danon; RC Block; JA Burke; NJ Drindak; G Leinweber; RV Ballad

    2004-01-01

    The focus of this work is to determine resonance parameters for stable hafnium isotopes in the 0.005-200 eV region, with special emphasis on the overlapping 176 Hf and 178 Hf resonances near 8 eV. The large neutron cross section of hafnium, combined with its corrosion resistance and excellent mechanical properties, make it a useful material for controlling nuclear reactions. Experiments measuring neutron capture and transmission were performed at the Rensselaer Polytechnic Institute (RPI) electron linear accelerator (LINAC) using the time of flight method. 6 Li glass scintillation detectors were used for transmission experiments at flight path lengths of 15 and 25 m. Capture experiments were done using a sixteen section NaI(Tl) multiplicity detector at a flight path length of 25 m. These experiments utilized various thicknesses of metallic and isotopically-enriched liquid samples. The liquid samples were designed to provide information on the 176 Hf and 178 Hf contributions to the 8 eV doublet without saturation. Data analysis was done using the R-matrix Bayesian code SAMMY version M6 beta. SAMMY is able to account for experimental resolution effects for each of the experimental setups at the RPI LINAC, and also can correct for multiple scattering effects in neutron capture yield data. The combined capture and transmission data analysis yielded resonance parameters for all hafnium isotopes from 0.005-200 eV. Resonance integrals were calculated along with errors for each hafnium isotope using the NJOY [1] and INTER [2] codes. The isotopic resonance integrals calculated were significantly different than previously published values; however the calculated elemental hafnium resonance integral changed very little

  18. Polarization experiments with photons in the nucleon resonances region

    International Nuclear Information System (INIS)

    Miczaika, T.S.

    1983-10-01

    I discuss the photoexcitation of the nucleaon γN->Nπ and the photodisintegration of the deuteron γd->pn. The photo-couplings to the nucleon resonances that are measured in these experiments can be compared to quark model calculations, and exact data on the smaller amplitudes can serve as input to refined theories. (orig./HSI)

  19. Simultaneous multislice triple-echo steady-state (SMS-TESS) T1 , T2 , PD, and off-resonance mapping in the human brain.

    Science.gov (United States)

    Heule, Rahel; Celicanin, Zarko; Kozerke, Sebastian; Bieri, Oliver

    2018-02-21

    To investigate the ability of simultaneous multislice triple-echo steady-state (SMS-TESS) imaging to provide quantitative maps of multiple tissue parameters, i.e., longitudinal and transverse relaxation times (T 1 and T 2 ), proton density (PD), and off-resonance (ΔB 0 ), in the human brain at 3T from a single scan. TESS acquisitions were performed in 2D mode to reduce motion sensitivity and accelerated by an SMS excitation scheme (CAIPIRINHA) with SENSE reconstruction. SMS-acceleration factors (R) of 2 and 4 were evaluated. The in vitro and in vivo validation process included standard reference scans to analyze the accuracy of T 1 , T 2 , and ΔB 0 estimates, as well as single-slice TESS measurements. For R = 2, the quantification of T 1 , T 2 , PD, and ΔB 0 was overall reliable with marginal noise enhancement. T 1 and T 2 values were in good agreement with the reference measurements and single-slice TESS. For R = 4, the agreement of ΔB 0 with the standard reference was excellent and the determination of T 1 , T 2 , and PD was reproducible; however, increased variations in T 1 and T 2 values with respect to single-slice TESS were observed. SMS-TESS has shown potential to offer rapid simultaneous T 1 , T 2 , PD, and ΔB 0 mapping of human brain tissues. © 2018 International Society for Magnetic Resonance in Medicine.

  20. Long-term operating experience for the ATLAS superconducting resonators

    International Nuclear Information System (INIS)

    Pardo, R.; Zinkann, G.

    1999-01-01

    Portions of the ATLAS accelerator have been operating now for over 21 years. The facility has accumulated several million resonator-hours of operation at this point and has demonstrated the long-term reliability of RF superconductivity. The overall operating performance of the ATLAS facility has established a level of beam quality, flexibility, and reliability not previously achieved with heavy-ion accelerator facilities. The actual operating experience and maintenance history of ATLAS are presented for ATLAS resonators and associated electronics systems. Solutions to problems that appeared in early operation as well as current problems needing further development are discussed

  1. Broadband electron spin resonance experiments using superconducting coplanar waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Clauss, Conrad; Bogani, Lapo; Scheffler, Marc; Dressel, Martin [1. Physikalisches Institut, Universitaet Stuttgart (Germany); Bothner, Daniel; Koelle, Dieter; Kleiner, Reinhold [Physikalisches Institut - Experimentalphysik II and Center for Collective Quantum Phenomena in LISA+, Universitaet Tuebingen (Germany)

    2012-07-01

    In recent years superconducting coplanar devices operating at microwave/GHz frequencies are employed in more and more experimental studies. Here, we present electron spin resonance (ESR) experiments using a superconducting coplanar waveguide to provide the RF field to drive the spin flips. In contrast to conventional ESR studies this allows broadband frequency as well as magnetic field swept observation of the spin resonance. We show experimental data of the spin resonance of the organic radical NitPhoMe (2-(4'-methoxyphenyl)-4,4,5,5-tetra-methylimidazoline-1-oxyl-3-oxide) for frequencies in the range of 1 GHz to 40 GHz and corresponding magnetic fields up to 1.4 T (for g=2). In addition we show the temperature dependence of the ESR signals for temperatures up to 30 K, which is well above the critical temperature of the niobium superconductor.

  2. Nonlinear Resonance Benchmarking Experiment at the CERN Proton Synchrotron

    CERN Document Server

    Hofmann, I; Giovannozzi, Massimo; Martini, M; Métral, Elias

    2003-01-01

    As a first step of a space charge - nonlinear resonance benchmarking experiment over a large number of turns, beam loss and emittance evolution were measured over 1 s on a 1.4 GeV kinetic energy flat-bottom in the presence of a single octupole. By lowering the working point towards the resonance a gradual transition from a loss-free core emittance blow-up to a regime dominated by continuous loss was found. Our 3D simulations with analytical space charge show that trapping on the resonance due to synchrotron oscillation causes the observed core emittance growth as well as halo formation, where the latter is explained as the source of the observed loss.

  3. Clinical characteristics of triple negative breast cancer in Egyptian women: a hospital-based experience

    Directory of Open Access Journals (Sweden)

    Nivine Gado

    2016-06-01

    Full Text Available Purpose: Triple negative breast cancer (TNBC is an aggressive subtype of breast cancer with poor prognosis despite the high rates of response to chemotherapy. We aim to study the clinical features, factors influencing recurrence and survival outcomes of TNBC patients.Methods: We retrospectively studied the charts of patients with biopsy proven TNBC treated at The Clinical Oncology Department Ain-Shams University between 2009 and 2012.Results: One hundred and forty five patients fulfilled the eligibility criteria. The incidence of TNBC was 10.5% - 15% with a mean of 12% of all breast cancer patients. The follow-up duration ranged from six months to four years. The age range was 26 to 78 years. Infiltrating ductal carcinoma represented 93.1% of the pathologic types. 87% of patients were free of metastases (M0 at presentation. Clinical stages II and III represented 38 and 39.5% of the patients. 66% of patients had modified radical mastectomy. Following surgery, 77.5% of patients received adjuvant chemotherapy while 61% of the patients had adjuvant radiation therapy. Anthracyclines based chemotherapy was given to 52% of patients. Disease-free survival (DFS of the M0 patients at 20 and 30 months was 92% and 80% respectively. Relapse occurred in 23% of M0 patients. After a mean duration of DFS of 15.1 months, the most common sites of metastases for relapsed M0 patients were pulmonary (44.8%, bone (41.4%, and locoregional (13.8%. The median overall survival (ORS of patients was 18 months (1 - 45 months, whereas for the M1 group of patients the median ORS was 9 months (2 - 29 months.Conclusion: The incidence, pathological characteristics, and clinical behavior of TNBC were similar to what is mentioned in the literature. Adding taxanes to the chemotherapy protocols and using postoperative radiotherapy were both associated with a significant increase in the mean period of DFS, while did not significantly affect the ORS.

  4. EZ-ASSIGN, a program for exhaustive NMR chemical shift assignments of large proteins from complete or incomplete triple-resonance data

    Energy Technology Data Exchange (ETDEWEB)

    Zuiderweg, Erik R. P., E-mail: zuiderwe@umich.edu; Bagai, Ireena [The University of Michigan Medical School, Department of Biological Chemistry (United States); Rossi, Paolo [Rutgers University, Center for Integrative Proteomics Research (United States); Bertelsen, Eric B. [Arbor Communications, Inc. (United States)

    2013-10-15

    For several of the proteins in the BioMagResBank larger than 200 residues, 60 % or fewer of the backbone resonances were assigned. But how reliable are those assignments? In contrast to complete assignments, where it is possible to check whether every triple-resonance Generalized Spin System (GSS) is assigned once and only once, with incomplete data one should compare all possible assignments and pick the best one. But that is not feasible: For example, for 200 residues and an incomplete set of 100 GSS, there are 1.6 Multiplication-Sign 10{sup 260} possible assignments. In 'EZ-ASSIGN', the protein sequence is divided in smaller unique fragments. Combined with intelligent search approaches, an exhaustive comparison of all possible assignments is now feasible using a laptop computer. The program was tested with experimental data of a 388-residue domain of the Hsp70 chaperone protein DnaK and for a 351-residue domain of a type III secretion ATPase. EZ-ASSIGN reproduced the hand assignments. It did slightly better than the computer program PINE (Bahrami et al. in PLoS Comput Biol 5(3):e1000307, 2009) and significantly outperformed SAGA (Crippen et al. in J Biomol NMR 46:281-298, 2010), AUTOASSIGN (Zimmerman et al. in J Mol Biol 269:592-610, 1997), and IBIS (Hyberts and Wagner in J Biomol NMR 26:335-344, 2003). Next, EZ-ASSIGN was used to investigate how well NMR data of decreasing completeness can be assigned. We found that the program could confidently assign fragments in very incomplete data. Here, EZ-ASSIGN dramatically outperformed all the other assignment programs tested.

  5. EZ-ASSIGN, a program for exhaustive NMR chemical shift assignments of large proteins from complete or incomplete triple-resonance data

    International Nuclear Information System (INIS)

    Zuiderweg, Erik R. P.; Bagai, Ireena; Rossi, Paolo; Bertelsen, Eric B.

    2013-01-01

    For several of the proteins in the BioMagResBank larger than 200 residues, 60 % or fewer of the backbone resonances were assigned. But how reliable are those assignments? In contrast to complete assignments, where it is possible to check whether every triple-resonance Generalized Spin System (GSS) is assigned once and only once, with incomplete data one should compare all possible assignments and pick the best one. But that is not feasible: For example, for 200 residues and an incomplete set of 100 GSS, there are 1.6 × 10 260 possible assignments. In “EZ-ASSIGN”, the protein sequence is divided in smaller unique fragments. Combined with intelligent search approaches, an exhaustive comparison of all possible assignments is now feasible using a laptop computer. The program was tested with experimental data of a 388-residue domain of the Hsp70 chaperone protein DnaK and for a 351-residue domain of a type III secretion ATPase. EZ-ASSIGN reproduced the hand assignments. It did slightly better than the computer program PINE (Bahrami et al. in PLoS Comput Biol 5(3):e1000307, 2009) and significantly outperformed SAGA (Crippen et al. in J Biomol NMR 46:281–298, 2010), AUTOASSIGN (Zimmerman et al. in J Mol Biol 269:592–610, 1997), and IBIS (Hyberts and Wagner in J Biomol NMR 26:335–344, 2003). Next, EZ-ASSIGN was used to investigate how well NMR data of decreasing completeness can be assigned. We found that the program could confidently assign fragments in very incomplete data. Here, EZ-ASSIGN dramatically outperformed all the other assignment programs tested

  6. A Compact Symmetric Microstrip Filter Based on a Rectangular Meandered-Line Stepped Impedance Resonator with a Triple-Band Bandstop Response

    Directory of Open Access Journals (Sweden)

    Rajendra Dhakal

    2013-01-01

    Full Text Available This paper presents a symmetric-type microstrip triple-band bandstop filter incorporating a tri-section meandered-line stepped impedance resonator (SIR. The length of each section of the meandered line is 0.16, 0.15, and 0.83 times the guided wavelength (λg, so that the filter features three stop bands at 2.59 GHz, 6.88 GHz, and 10.67 GHz, respectively. Two symmetric SIRs are employed with a microstrip transmission line to obtain wide bandwidths of 1.12, 1.34, and 0.89 GHz at the corresponding stop bands. Furthermore, an equivalent circuit model of the proposed filter is developed, and the model matches the electromagnetic simulations well. The return losses of the fabricated filter are measured to be −29.90 dB, −28.29 dB, and −26.66 dB while the insertion losses are 0.40 dB, 0.90 dB, and 1.10 dB at the respective stop bands. A drastic reduction in the size of the filter was achieved by using a simplified architecture based on a meandered-line SIR.

  7. Resonant production of dark photons in positron beam dump experiments

    Science.gov (United States)

    Nardi, Enrico; Carvajal, Cristian D. R.; Ghoshal, Anish; Meloni, Davide; Raggi, Mauro

    2018-05-01

    Positrons beam dump experiments have unique features to search for very narrow resonances coupled superweakly to e+e- pairs. Due to the continued loss of energy from soft photon bremsstrahlung, in the first few radiation lengths of the dump a positron beam can continuously scan for resonant production of new resonances via e+ annihilation off an atomic e- in the target. In the case of a dark photon A' kinetically mixed with the photon, this production mode is of first order in the electromagnetic coupling α , and thus parametrically enhanced with respect to the O (α2)e+e-→γ A' production mode and to the O (α3)A' bremsstrahlung in e- -nucleon scattering so far considered. If the lifetime is sufficiently long to allow the A' to exit the dump, A'→e+e- decays could be easily detected and distinguished from backgrounds. We explore the foreseeable sensitivity of the Frascati PADME experiment in searching with this technique for the 17 MeV dark photon invoked to explain the Be 8 anomaly in nuclear transitions.

  8. Nitrogen-detected CAN and CON experiments as alternative experiments for main chain NMR resonance assignments

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Heffron, Gregory; Sun, Zhen-Yu J.; Frueh, Dominique P.; Wagner, Gerhard

    2010-01-01

    Heteronuclear direct-detection experiments, which utilize the slower relaxation properties of low γ nuclei, such as 13 C have recently been proposed for sequence-specific assignment and structural analyses of large, unstructured, and/or paramagnetic proteins. Here we present two novel 15 N direct-detection experiments. The CAN experiment sequentially connects amide 15 N resonances using 13 C α chemical shift matching, and the CON experiment connects the preceding 13 C' nuclei. When starting from the same carbon polarization, the intensities of nitrogen signals detected in the CAN or CON experiments would be expected four times lower than those of carbon resonances observed in the corresponding 13 C-detecting experiment, NCA-DIPAP or NCO-IPAP (Bermel et al. 2006b; Takeuchi et al. 2008). However, the disadvantage due to the lower γ is counteracted by the slower 15 N transverse relaxation during detection, the possibility for more efficient decoupling in both dimensions, and relaxation optimized properties of the pulse sequences. As a result, the median S/N in the 15 N observe CAN experiment is 16% higher than in the 13 C observe NCA-DIPAP experiment. In addition, significantly higher sensitivity was observed for those residues that are hard to detect in the NCA-DIPAP experiment, such as Gly, Ser and residues with high-field C α resonances. Both CAN and CON experiments are able to detect Pro resonances that would not be observed in conventional proton-detected experiments. In addition, those experiments are free from problems of incomplete deuterium-to-proton back exchange in amide positions of perdeuterated proteins expressed in D 2 O. Thus, these features and the superior resolution of 15 N-detected experiments provide an attractive alternative for main chain assignments. The experiments are demonstrated with the small model protein GB1 at conditions simulating a 150 kDa protein, and the 52 kDa glutathione S-transferase dimer, GST.

  9. Development of triple GEM detector for a heavy ion physics experiment

    International Nuclear Information System (INIS)

    Bhardwaj, A.; Biswal, K.; Gupta, R.

    2015-01-01

    Building and testing of micro-pattern gas detector such as Gas Electron Multiplier (GEM) for several upcoming High-Energy Physics (HEP) experiment projects, is an advance area of research in the field of detector development. We have carried out the long-term stability test and the uniformity of the relative gain over a GEM detector. The method of long-term test and uniformity of the relative gain and the results are presented in this article

  10. Triple-GEM detectors for the innermost region of the muon apparatus at the LHCb experiment

    CERN Document Server

    Poli-Lener, M; Bencivenni, G

    2005-01-01

    The LHCb experiment will take place at the future LHC accelerator at CERN and will start in 2007. It is a single arm spectrometer to precision measurements of CP violation and rare decays in the b quark sector. Recent experimental results have shown that CP violation is large in this sector. LHCb is designed with a robust and flexible trigger in order to extensively gain access to a wide spread of different physical processes involving the beauty particles. This will allow to over-constrain the Standard Model predictions about $\\mathcal{CP}$ violation, and to discover any possible inconsistency, which would reveal the presence of ''New Physics''. The work presented in this thesis has two main parts: the development of a charged particle detector based on Gas Electron Multiplication (GEM) and the study of luminosity measurements with the physical channels $Z^{0} \\rightarrow \\mu^{+} \\mu^{-}$ and $W^{\\pm} \\rightarrow \\mu^{\\pm} \

  11. Atomic-Beam Magnetic Resonance Experiments at ISOLDE

    CERN Multimedia

    2002-01-01

    The aim of the atomic-beam magnetic resonance (ABMR) experiments at ISOLDE is to map the nuclear behaviour in wide regions of the nuclear chart by measuring nuclear spins and moments of ground and isomeric states. This is made through an investigation of the atomic hyperfine structure of free, neutral atoms in a thermal atomic-beam using radio-frequency techniques. On-line operation allows the study of short-lived nuclei far from the region of beta-stability.\\\\ \\\\ The ABMR experiments on the |2S^1 ^2 elements Rb, Cs, Au and Fr have been completed, and present efforts are directed towards the elements with an open p-shell and on the rare-earth elements.\\\\ \\\\ The experimental data obtained are compared with results from model calculations, giving information on the single-particle structure and on the nuclear shape parameters.

  12. Neutron multiwave interference with many resonance coils: a test experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chetverikov, Yu.O.; Axelrod, L.A.; Syromyatnikov, A.V.; Kraan, W.H.; Rekveldt, M.Th.; Grigoriev, S.V

    2004-07-15

    A test experiment on neutron multiwave interference based on Ramsey's resonance method of 'separated oscillating fields' has been performed. A neutron passes through N successive resonant coils (h{omega}{sub 0}=2{mu}{sub n}B{sub 0}), which flip the neutron spin with a probability {rho} smaller than 1. These coils are separated by path lengths L, over which a homogeneous field B{sub 1} is present. Since the spin-flip probability {rho} is smaller than 1, the number of waves for a neutron is doubled after each flipper, so as to produce 2{sup N} neutron waves at the end of the setup. The phase difference between any pair of waves is a multiple of a 'phase quantum' determined by the line integral of the field difference B{sub 1}-B{sub 0} over the length L. Highly regular patterns of the quantum mechanical probability R in (B{sub 1},{rho})--space appear owing to pairwise interference between individual waves.

  13. Nuclear magnetic resonance experiments with dc SQUID amplifiers

    International Nuclear Information System (INIS)

    Heaney, M.B.

    1990-11-01

    The development and fabrication of dc SQUIDs (Superconducting QUantum Interference Devices) with Nb/Al 2 O 3 /Nb Josephson junctions is described. A theory of the dc SQUID as a radio-frequency amplifier is presented, with an optimization strategy that accounts for the loading and noise contributions of the postamplifier and maximizes the signal-to-noise ratio of the total system. The high sensitivity of the dc SQUID is extended to high field NMR. A dc SQUID is used as a tuned radio-frequency amplifier to detect pulsed nuclear magnetic resonance at 32 MHz from a metal film in a 3.5 Tesla static field. A total system noise temperature of 11 K has been achieved, at a bath temperature of 4.2 K. The minimum number of nuclear Bohr magnetons observable from a free precession signal after a single pulse is about 2 x 10 17 in a bandwidth of 25 kHz. In a separate experiment, a dc SQUID is used as a rf amplifier in a NQR experiment to observe a new resonance response mechanism. The net electric polarization of a NaClO 3 crystal due to the precessing electric quadrupole moments of the Cl nuclei is detected at 30 MHz. The sensitivity of NMR and NQR spectrometers using dc SQUID amplifiers is compared to the sensitivity of spectrometers using conventional rf amplifiers. A SQUID-based spectrometer has a voltage sensitivity which is comparable to the best achieved by a FET-based spectrometer, at these temperatures and operating frequencies

  14. Versatile resonance-tracking circuit for acoustic levitation experiments.

    Science.gov (United States)

    Baxter, K; Apfel, R E; Marston, P L

    1978-02-01

    Objects can be levitated by radiation pressure forces in an acoustic standing wave. In many circumstances it is important that the standing wave frequency remain locked on an acoustic resonance despite small changes in the resonance frequency. A self-locking oscillator circuit is described which tracks the resonance frequency by sensing the magnitude of the transducer current. The tracking principle could be applied to other resonant systems.

  15. Use of triple microcatheters for endovascular treatment of wide-necked intracranial aneurysms: A single center experience

    International Nuclear Information System (INIS)

    Cho, Young Dae; Rhim, Jong Kook; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee; Park, Jeong Jin; Jeon, Jin Pyeong

    2015-01-01

    The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-necked intracranial aneurysms. Data accruing prospectively between January 2006 and October 2014 on simultaneously executed triple microcatheter coil embolization procedures done in 38 saccular aneurysms were reviewed. Clinical and morphological outcomes were assessed, with emphasis on technical aspects of treatment. The triple microcatheter technique was successfully applied to all 38 saccular aneurysms, involving the posterior communicating artery (n = 13), the middle cerebral artery (n = 10), the basilar tip (n = 7), the anterior cerebral artery (n = 5), and the internal carotid artery (n = 3). Stent protection was added in four patients and balloon remodeling in one. Dual microcatheters (n = 24) were usually deployed to deliver the coil within sacs of aneurysms, with the additional microcatheter used for protection. Otherwise, triple microcatheters were deployed for coil delivery (n = 11) or coils were delivered via a single microcatheter, with dual microcatheters deployed for protection (n = 3). Successful occlusion of aneurysms was achieved in 89.5% of cases, with no procedure-related morbidity or mortality. Stable occlusion was maintained in 72.2% (26/36) of the aneurysms at the final follow-up (mean interval, 30.2 ± 22.7 months). The outcomes of this limited study suggest that the triple microcatheter technique may be an effective and safe therapeutic option for wide-necked aneurysms, using technical strategies tailored to complex angio-anatomic configurations

  16. Experiments on shear Alfven resonance in a tokamak

    International Nuclear Information System (INIS)

    Prager, S.C.; Witherspoon, F.D.; Kieras, C.E.; Kortbawi, D.; Sprott, J.C.; Tataronis, J.A.

    1983-02-01

    Detailed observations have been made of the spatial structure of the wave magnetic field. Measurements of the resonance properties such as radial location, wave polarization, resonance width and risetime are all consistent with shear Alfven resonance theory, although several measurements require improvement in resolution. The resonance location agrees with prediction of a fully two-dimensional ideal MHD theory for the Tokapole II device. To complete the identification a frequency scan and careful comparison of the observed resonance with antenna loading will be undertaken

  17. Magnetic resonance imaging of the female pelvis: initial experience

    International Nuclear Information System (INIS)

    Hricak, H.; Alpers, C.; Crooks, L.E.; Sheldon, P.E.

    1983-01-01

    The potential of magnetic resonance imaging (MRI) was evaluated in 21 female subjects: seven volunteers, 12 patients scanned for reasons unrelated to the lower genitourinary tract, and two patients referred with gynecologic disease. The uterus at several stages was examined; the premenarcheal uterus (one patient), the uterus of reproductive age (12 patients), the postmenopausal uterus (two patients), and in an 8 week pregnancy (one patient). The myometrium and cyclic endometrium in the reproductive age separated by a low-intensity line (probably stratum basale), which allows recognition of changes in thickness of the cyclic endometrium during the menstrual cycle. The corpus uteri can be distinguished from the cervix by the transitional zone of the isthmus. The anatomic relation of the uterus to bladder and rectum is easily outlined. The vagina can be distinguished from the cervix, and the anatomic display of the closely apposed bladder, vagina, and rectum is clear on axial and coronal images. The ovary is identified; the signal intensity from the ovary depends on the acquisition parameter used. Uterine leiomyoma, endometriosis, and dermoid cyst were depicted, but further experience is needed to ascertain the specificity of the findings

  18. Experiments on resonantly photo-pumped x-ray lasers

    International Nuclear Information System (INIS)

    Nilsen, J.; Porter, J.L.; Da Silva, L.B.; MacGowan, B.; Beiersdorfer, P..; Elliott, S.R.; Young, B.K.

    1992-01-01

    We describe our recent effort to identify and study a promising resonantly photopumped x-ray laser scheme. In particular we will describe a scheme which uses the strong emission lines of a nickel-like ion to resonantly photo-pump a neon-like ion and enhance the lasing of the neon-like 3p → 3s transitions

  19. Dynamic magnetic resonance of pelvic floor: experience in 38 patients

    International Nuclear Information System (INIS)

    Ocantos, Jorge; Fattal Jaef, Virginia; Pietrani, Marcelo; Seclen, Maria F.; Seehaus, Alberto; Sarsotti, Carlos

    2005-01-01

    Purpose: To show the experience in the evaluation of dysfunctions of pelvic floor by dynamic magnetic resonance (DMR) and to describe the structural and dynamic disorders of pelvis organs. Material and Methods: From March 2004 to March 2005 38 patients with pelvic floor disorders have been studied, 33/38 women (86, 84 %) and 5/38 men (15,16 %), ages between 16 and 74 years old. An evacuating rectal enema has been indicated 4 hours before the examination with bladder retention of 3 hours. 180-240 cc of semisolid paste (thin oats and saline solution) has been used to distend rectum until patients refer sensation of rectum full or a maximum of 240 cm 3 . The study has been performed in a Siemens Magnetom Vision (1.5 T) body array and coil CP Body Array Flex. T2 turbo spin eco axial and sagittal (TR 4700, TE1, 32), T1 coronal (TR 580 TE 14) with a 4 mm slice were selected for static sequences and Siemens TRUFI sagittal (TR 4.8 TE 2.3) for dynamic acquisitions during rectal and voiding evacuations. The morphology and symmetry of peri urethral ligaments (PUL), elevator anus muscle (LA), and vagina (V) was evaluated. The organs prolapse was evaluated at rest and maximal pelvis strain in accord with Comiter parameters (Fielding J.R.). Results: At 10/38 (26, 32 %) patients was not detected lesions. In 28/38 P (73,68 %) 75 defects of the pelvic supports (54,6 % of LA, 14,6% of the vagina V, 9,3% of PUL and other 21,3 %). The dynamic sequences show 59 defects, 50, 84 % of posterior compartment and 49,16% of anterior. In 8/38 (28, 57 %) patients the lesions affected both compartment. Conclusion: Dynamic magnetic resonance allows the direct interpretation of the very small pelvic floor structure and its disorders (not available by other methods) and the dynamic study of prolapse, providing a more accurate interpretation of its causes. DRM can be very useful in patients with multi-compartment involvement, complex prolapse or recurrence of symptoms post surgical repair. (author

  20. Opto-mechanical design of vacuum laser resonator for the OSQAR experiment

    Science.gov (United States)

    Hošek, Jan; Macúchová, Karolina; Nemcová, Šárka; Kunc, Štěpán.; Šulc, Miroslav

    2015-01-01

    This paper gives short overview of laser-based experiment OSQAR at CERN which is focused on search of axions and axion-like particles. The OSQAR experiment uses two experimental methods for axion search - measurement of the ultra-fine vacuum magnetic birefringence and a method based on the "Light shining through the wall" experiment. Because both experimental methods have reached its attainable limits of sensitivity we have focused on designing a vacuum laser resonator. The resonator will increase the number of convertible photons and their endurance time within the magnetic field. This paper presents an opto-mechanical design of a two component transportable vacuum laser resonator. Developed optical resonator mechanical design allows to be used as a 0.8 meter long prototype laser resonator for laboratory testing and after transportation and replacement of the mirrors it can be mounted on the LHC magnet in CERN to form a 20 meter long vacuum laser resonator.

  1. Effect of Impurities on the Triple Point of Water: Experiments with Doped Cells at Different Liquid Fractions

    Science.gov (United States)

    Dobre, M.; Peruzzi, A.; Kalemci, M.; Van Geel, J.; Maeck, M.; Uytun, A.

    2018-05-01

    Recent international comparisons showed that there is still room for improvement in triple point of water (TPW) realization uncertainty. Large groups of cells manufactured, maintained and measured in similar conditions still show a spread in the realized TPW temperature that is larger than the best measurement uncertainties (25 µK). One cause is the time-dependent concentration of dissolved impurities in water. The origin of such impurities is the glass/quartz envelope dissolution during a cell lifetime. The effect is a difference in the triple point temperature proportional to the impurities concentration. In order to measure this temperature difference and to investigate the effect of different types of impurities, we manufactured doped cells with different concentrations of silicon (Si), boron (B), sodium (Na) and potassium (K), the glass main chemical components. To identify any influence of the filling process, two completely independent manufacturing procedures were followed in two different laboratories, both national metrology institutes (VSL, Netherlands and UME, Turkey). Cells glass and filling water were also different while the doping materials were identical. Measuring the temperature difference as a function of the liquid fraction is a method to obtain information about impurities concentrations in TPW. Only cells doped with 1 µmol·mol-1 B, Na and K proved to be suitable for measurements at different liquid fractions. We present here the results with related uncertainties and discuss the critical points in this experimental approach.

  2. NMR magnetic field controller for pulsed nuclear magnetic resonance experiments

    International Nuclear Information System (INIS)

    Scheler, G.; Anacker, M.

    1975-01-01

    A nuclear magnetic resonance controller for magnetic fields, which can also be used for pulsed NMR investigations, is described. A longtime stability of 10 -7 is achieved. The control signal is generated by a modified time sharing circuit with resonance at the first side band of the 2 H signal. An exact calibration of the magnetic field is achieved by the variation of the H 1 - or of the time-sharing frequency. (author)

  3. Resonance cones below the ion cyclotron frequency: theory and experiment

    International Nuclear Information System (INIS)

    Bellan, P.

    1976-03-01

    The resonance cones existing below the ion cyclotron frequency, ω/sub c/sub i//, are shown, theoretically and experimentally, to be the asymptotes of hyperbolic constant-phase surfaces of low-frequency ion acoustic waves. Above ω/sub c/sub i// the surfaces transform into ellipses that are related to the electrostatic ion cyclotron waves and ion acoustic waves

  4. Ion cyclotron resonant heating 2 x 1700 loop antenna for the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Brooksby, C.A.; Ferguson, S.W.; Molvik, A.W.; Barter, J.

    1985-01-01

    This paper reviews the mechanical design and improvements that have taken place on the loop type ion cyclotron resonance heating (ICRH) antennas that are located in the center cell region of the Tandem Mirror Experiment-Upgrade (TMX-U)

  5. Clinical experience of magnetic resonance angiography in hand surgery

    International Nuclear Information System (INIS)

    Kawabata, Hidehiko; Yasui, Natsuo; Kitano, Motohiro; Sai, Eikoh

    1996-01-01

    Magnetic resonance angiography was performed in fourteen patients with congenital hand abnormalities. A two-dimentional time-of-flight imaging clearly demonstrated presence or absence of the radial, ulnar, and anterior interosseous arteires at forearm. However, smaller arteries such as digital arteries were depressed sometimes. This fact makes clinical application of the method somewhat limited. At present. appropriate applications in orthopaedic fields are evaluation of run-off of the major vessels after trauma or atherosclerotic diseases, venous vascular problems such as thrombophlebitis and aneurysm, and preoperative and post operative evaluation in microsurgery. If more detailed information is required, for example, in differential diagnosis of tumors conventional angiography or digital subtraction angiography is recommended. Because magnetic resonance angiography is non-invasive and does not need anesthesia, it is suitable especially for children. No requirement of contrast medium makes it easy to apply angiography to high risk patients and allergic patients to iodine. Technical advancement in near future will rise up magnetic resonance angiography to a standard evaluation method for vascular problems in orthopaedic fields very soon. (author)

  6. Resonance

    DEFF Research Database (Denmark)

    Petersen, Nils Holger

    2014-01-01

    A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice.......A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice....

  7. Parity violation in neutron resonances

    International Nuclear Information System (INIS)

    Mitchell, G.E.; Lowie, L.Y.; Bowman, J.D.; Knudson, J.; Crawford, B.E.; Delheij, P.P.J.; Haseyama, T.; Masaike, A.; Matsuda, Y.; Masuda, Y.

    1997-01-01

    The observation of very large parity violation in neutron resonances has led to a new approach to the study of symmetry breaking in nuclei. The origin of the enhancement of parity violation is discussed, as well as the new (statistical) analysis approach. The TRIPLE experimental system and analysis methods, their improvements are described. Sign correlation and results from recent parity violation experiments are presented and discussed. (author)

  8. Study of W boson decays and determination of Triple Gauge Couplings in the frame of ALEPH experiment

    International Nuclear Information System (INIS)

    Chazelle, Guy

    1999-01-01

    One of the most important consequence of the fundamental non-Abelian gauge structure of the Electroweak Standard Model is the existence of Triple Gauge-boson Couplings (TGC's). The start of LEP 2 has made it possible for the first time to test the least bound sector of the Standard Model, via the study of the γW + W - and Z 0 W + W - vertices. The accuracy is limited by the ambiguities that exist on the different production angles of the quarks and the W - production angle. These ambiguities can be removed if one is able to distinguish between the up quark and the down quark in the hadronic decays of the W. A charm-jet tagger was therefore developed. It is based on a neural network with 12 variables as input, using mainly charm-lifetime, jet-shape properties, reconstruction of D-mesons and lepton identification. This study has lead to the measurement of one of the least well known CKM matrix element, |V cs | = 1.034 ± 0.051 stat ± 0.029 syst . The measurement of the TGC's with the ALEPH detector has led to a dedicated selection of the purely leptonic final states lν-bar l-bar ν (l=e,μ). The potential sensitivity of this channel to the TGC's depends strongly on the kinematic reconstruction of the undetected neutrinos. A kinematic fitting procedure has thus been developed. The method used to measure the TGC's in this analysis is based on the definition of optimal observables which project out the information contained in the five-fold angular distribution to a set of one-dimensional distributions. The results obtained from the data collected at 183 GeV (1997) and 189 GeV (1998) combined with those obtained from the study of νν-bar γ final states and single W events yield the following 95% confidence level limits: - 0.113 1 Z γ γ NP = 1 TeV, confirming the previously published electroweak results from LEP 1 and SLC. (author)

  9. Measuring ac losses in superconducting cables using a resonant circuit:Resonant current experiment (RESCUE)

    DEFF Research Database (Denmark)

    Däumling, Manfred; Olsen, Søren Krüger; Rasmussen, Carsten

    1998-01-01

    be recorded using, for example, a digital oscilloscope. The amplitude decay of the periodic voltage or current accurately reflects the power loss in the system. It consists of two components-an ohmic purely exponential one (from leads, contacts, etc.), and a nonexponential component originating from......A simple way to obtain true ac losses with a resonant circuit containing a superconductor, using the decay of the circuit current, is described. For the measurement a capacitor is short circuited with a superconducting cable. Energy in the circuit is provided by either charging up the capacitors...... with a certain voltage, or letting a de flow in the superconductor. When the oscillations are started-either by opening a switch in case a de is flowing or by closing a switch to connect the charged capacitors with the superconductor-the current (via a Rogowski coil) or the voltage on the capacitor can...

  10. Nuclear magnetic resonance analogs of the Greenberger-Horne-Zeilinger experiment

    International Nuclear Information System (INIS)

    Lloyd, S.

    1998-01-01

    It has been recently shown that analogs of the Greenberger-Horne-Zeilinger experiment, which demonstrates the impossibility of certain types of local hidden variable theories in quantum mechanics, can be performed using nuclear magnetic resonance on spins in molecules at finite temperature. This paper examines the role of decoherence in the microscopic 'measurements' used to perform the NMR experiments. (author)

  11. Photoproduction of Baryon Resonances First Results of the Crystal Barrel Experiment at ELSA

    International Nuclear Information System (INIS)

    Junkersfeld, J.

    2002-01-01

    Photoproduction data on various final states involving neutral mesons have been taken by the CB-ELSA-experiment at the Electron Stretcher Accelerator ELSA (Bonn). The data show clear structures due to resonance production. Evidence for successive decays of high-mass nucleon resonances via Δ(1232)π 0 , Δ(1232)η and N(1535)S 11 π 0 have been observed. There is evidence for production of a 0 (980)-mesons in their π 0 η decay. (author)

  12. Acoustic resonances of fluid-immersed elastic cylinders and spheroids: Theory and experiment

    Science.gov (United States)

    Niemiec, Jan; Überall, Herbert; Bao, X. L.

    2002-05-01

    Frequency resonances in the scattering of acoustic waves from a target object are caused by the phase matching of surface waves repeatedly encircling the object. This is exemplified here by considering elastic finite cylinders and spheroids, and the phase-matching condition provides a means of calculating the complex resonance frequencies of such objects. Tank experiments carried out at Catholic University, or at the University of Le Havre, France by G. Maze and J. Ripoche, have been interpreted using this approach. The experiments employed sound pulses to measure arrival times, which allowed identification of the surface paths taken by the surface waves, thus giving rise to resonances in the scattering amplitude. A calculation of the resonance frequencies using the T-matrix approach showed satisfactory agreement with the experimental resonance frequencies that were either measured directly (as at Le Havre), or that were obtained by the interpretation of measured arrival times (at Catholic University) using calculated surface wave paths, and the extraction of resonance frequencies therefrom, on the basis of the phase-matching condition. Results for hemispherically endcapped, evacuated steel cylinders obtained in a lake experiment carried out by the NSWC were interpreted in the same fashion.

  13. Magnetic Resonance Fingerprinting of Adult Brain Tumors: Initial Experience

    Science.gov (United States)

    Badve, Chaitra; Yu, Alice; Dastmalchian, Sara; Rogers, Matthew; Ma, Dan; Jiang, Yun; Margevicius, Seunghee; Pahwa, Shivani; Lu, Ziang; Schluchter, Mark; Sunshine, Jeffrey; Griswold, Mark; Sloan, Andrew; Gulani, Vikas

    2016-01-01

    Background Magnetic resonance fingerprinting (MRF) allows rapid simultaneous quantification of T1 and T2 relaxation times. This study assesses the utility of MRF in differentiating between common types of adult intra-axial brain tumors. Methods MRF acquisition was performed in 31 patients with untreated intra-axial brain tumors: 17 glioblastomas, 6 WHO grade II lower-grade gliomas and 8 metastases. T1, T2 of the solid tumor (ST), immediate peritumoral white matter (PW), and contralateral white matter (CW) were summarized within each region of interest. Statistical comparisons on mean, standard deviation, skewness and kurtosis were performed using univariate Wilcoxon rank sum test across various tumor types. Bonferroni correction was used to correct for multiple comparisons testing. Multivariable logistic regression analysis was performed for discrimination between glioblastomas and metastases and area under the receiver operator curve (AUC) was calculated. Results Mean T2 values could differentiate solid tumor regions of lower-grade gliomas from metastases (mean±sd: 172±53ms and 105±27ms respectively, p =0.004, significant after Bonferroni correction). Mean T1 of PW surrounding lower-grade gliomas differed from PW around glioblastomas (mean±sd: 1066±218ms and 1578±331ms respectively, p=0.004, significant after Bonferroni correction). Logistic regression analysis revealed that mean T2 of ST offered best separation between glioblastomas and metastases with AUC of 0.86 (95% CI 0.69–1.00, p<0.0001). Conclusion MRF allows rapid simultaneous T1, T2 measurement in brain tumors and surrounding tissues. MRF based relaxometry can identify quantitative differences between solid-tumor regions of lower grade gliomas and metastases and between peritumoral regions of glioblastomas and lower grade gliomas. PMID:28034994

  14. Resonances

    DEFF Research Database (Denmark)

    an impetus or drive to that account: change, innovation, rupture, or discontinuity. Resonances: Historical Essays on Continuity and Change explores the historiographical question of the modes of interrelation between these motifs in historical narratives. The essays in the collection attempt to realize...

  15. Paediatric magnetic resonance enteroclysis under general anaesthesia - initial experience

    International Nuclear Information System (INIS)

    Sadigh, Sophie; Chopra, Mark; Olsen, Oeystein E.; Watson, Tom A.; Sury, Michael R.; Shah, Neil

    2017-01-01

    MR enterography is the accepted imaging reference standard for small bowel assessment in inflammatory bowel disease. There is an increasing cohort of children with inflammatory bowel disease presenting at an early age (<5 years) with severe disease. Younger children present a technical challenge for enterography because of the need for sedation/general anaesthesia to allow image optimisation and the need for oral contrast to allow adequate luminal assessment. Through our experiences, MR enteroclysis under general anaesthesia has proven to be a successful imaging technique for the work-up of these patients. In this paper, we present our institutional practice for performing MR enteroclysis under general anaesthesia. (orig.)

  16. Paediatric magnetic resonance enteroclysis under general anaesthesia - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Sadigh, Sophie; Chopra, Mark; Olsen, Oeystein E.; Watson, Tom A. [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Radiology, London (United Kingdom); Sury, Michael R. [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Anaesthetics, London (United Kingdom); Shah, Neil [Great Ormond Street Hospital NHS Foundation Trust, Department of Paediatric Gastroenterology, London (United Kingdom)

    2017-06-15

    MR enterography is the accepted imaging reference standard for small bowel assessment in inflammatory bowel disease. There is an increasing cohort of children with inflammatory bowel disease presenting at an early age (<5 years) with severe disease. Younger children present a technical challenge for enterography because of the need for sedation/general anaesthesia to allow image optimisation and the need for oral contrast to allow adequate luminal assessment. Through our experiences, MR enteroclysis under general anaesthesia has proven to be a successful imaging technique for the work-up of these patients. In this paper, we present our institutional practice for performing MR enteroclysis under general anaesthesia. (orig.)

  17. Cavity Resonator Wireless Power Transfer System for Freely Moving Animal Experiments.

    Science.gov (United States)

    Mei, Henry; Thackston, Kyle A; Bercich, Rebecca A; Jefferys, John G R; Irazoqui, Pedro P

    2017-04-01

    The goal of this paper is to create a large wireless powering arena for powering small devices implanted in freely behaving rodents. We design a cavity resonator based wireless power transfer (WPT) system and utilize our previously developed optimal impedance matching methodology to achieve effective WPT performance for operating sophisticated implantable devices, made with miniature receive coils (powering fidelity of 93.53% over nine recording sessions across nine weeks, indicating nearly continuous device operation for a freely behaving rat within the large cavity resonator space. We have developed and demonstrated a cavity resonator based WPT system for long term experiments involving freely behaving small animals. This cavity resonator based WPT system offers an effective and simple method for wirelessly powering miniaturized devices implanted in freely moving small animals within the largest space.

  18. Investigation of the Pygmy Dipole Resonance in (alpha, alpha 'gamma) coincidence experiments

    NARCIS (Netherlands)

    Savran, D.; Babilon, M.; van den Berg, A. M.; Harakeh, M. N.; Hasper, J.; Wortche, H. J.; Zilges, A.

    2007-01-01

    We report on first results from experiments using the (alpha, alpha'gamma) reaction at E alpha = 136 MeV to investigate bound electric dipole (El) excitations building the so-called Pygmy Dipole Resonance (PDR) in the semi-magic nucleus Ce-140. The method of (alpha, alpha'gamma) allows the

  19. Analyzing through Resonant Experience - Becoming the one to understand the other

    DEFF Research Database (Denmark)

    Revsbæk, Line

    in instances of listening to audio recorded case study material (Revsbæk & Tanggaard, 2015). Iterating the practice of ‘analyzing in the present’ (Ibid.), I take an (auto-)biographic approach to analyzing case study material, drawing on resonant experience of my own to understand that expressed by the (case...

  20. 4D experiments measured with APSY for automated backbone resonance assignments of large proteins

    International Nuclear Information System (INIS)

    Krähenbühl, Barbara; Boudet, Julien; Wider, Gerhard

    2013-01-01

    Detailed structural and functional characterization of proteins by solution NMR requires sequence-specific resonance assignment. We present a set of transverse relaxation optimization (TROSY) based four-dimensional automated projection spectroscopy (APSY) experiments which are designed for resonance assignments of proteins with a size up to 40 kDa, namely HNCACO, HNCOCA, HNCACB and HN(CO)CACB. These higher-dimensional experiments include several sensitivity-optimizing features such as multiple quantum parallel evolution in a ‘just-in-time’ manner, aliased off-resonance evolution, evolution-time optimized APSY acquisition, selective water-handling and TROSY. The experiments were acquired within the concept of APSY, but they can also be used within the framework of sparsely sampled experiments. The multidimensional peak lists derived with APSY provided chemical shifts with an approximately 20 times higher precision than conventional methods usually do, and allowed the assignment of 90 % of the backbone resonances of the perdeuterated primase-polymerase ORF904, which contains 331 amino acid residues and has a molecular weight of 38.4 kDa.

  1. Experiments on the interaction between long Josephson junctions and a coplanar strip resonator

    DEFF Research Database (Denmark)

    Davidson, A.; Pedersen, Niels Falsig

    1992-01-01

    Experiments are reported on a new geometry designed to couple long Josephson junction fluxon oscillators to a resonant cavity. The junctions were made with a niobium-aluminum oxide-niobium trilayer process with a critical-current density of around 1000 A/cm2. Various numbers of such junctions wer...

  2. Ultrafast electron field emission from gold resonant antennas studied by two terahertz pulse experiments

    DEFF Research Database (Denmark)

    Iwaszczuk, Krzysztof; Zalkovskij, Maksim; Strikwerda, Andrew C.

    2015-01-01

    Summary form only given. Ultrafast electron field emission from gold resonant antennas induced by strong terahertz (THz) transient is investigated using two THz pulse experiments. It is shown that UV emission from nitrogen plasma generated by liberated electrons is a good indication of the local...

  3. High temperature EXAFS experiments in molten actinide fluorides: The challenge of a triple containment cell for radioactive and aggressive liquids

    Science.gov (United States)

    Bessada, Catherine; Zanghi, Didier; Pauvert, Olivier; Maksoud, Louis; Gil-Martin, Ana; Sarou-Kanian, Vincent; Melin, Philippe; Brassamin, Séverine; Nezu, Atsushi; Matsuura, Haruaki

    2017-10-01

    An airtight double barrier cell with simple geometry has been developed for X-rays absorption measurements at high temperature in solid and molten actinide fluorides. The aim was both to improve the air tightness, to avoid any possible leakage and to maintain the high quality of the signal. The dimensions of the heating chamber were also constrained and minimized to be compatible with the limited space available usually on synchrotron beam lines and with a geometry suitable for absorption/diffraction measurements at high temperature. The design of the double barrier cell was also driven by the safety requirements in every experiment involving radioactive materials. The furnace itself was designed to ensure easy operating modes and disassembly, the aim being to consider the furnace as the ultimate containment. The cell has been tested with different molten fluorides up to more than 1000 °C, starting from non-radioactive LiF-ZrF4 mixtures in order to prove that the cell is absolutely airtight and that not any contamination of the environment occurs. Then it has been successfully applied to thorium fluoride- and uranium fluoride-alkali fluorides mixtures.

  4. No oxygen isotope exchange between water and APS-sulfate at surface temperature: Evidence from quantum chemical modeling and triple-oxygen isotope experiments

    Science.gov (United States)

    Kohl, Issaku E.; Asatryan, Rubik; Bao, Huiming

    2012-10-01

    In both laboratory experiments and natural environments where microbial dissimilatory sulfate reduction (MDSR) occurs in a closed system, the δ34S ((34S/32S)sample/(34S/32S)standard - 1) for dissolved SO42- has been found to follow a typical Rayleigh-Distillation path. In contrast, the corresponding δ18O ((18O/16O)sample/(18O/16O)standard) - 1) is seen to plateau with an apparent enrichment of between 23‰ and 29‰ relative to that of ambient water under surface conditions. This apparent steady-state in the observed difference between δ18O and δ18OO can be attributed to any of these three steps: (1) the formation of adenosine-5'-phosphosulfate (APS) from ATP and SO42-, (2) oxygen exchange between sulfite (or other downstream sulfoxy-anions) and water later in the MDSR reaction chain and its back reaction to APS and sulfate, and (3) the re-oxidation of produced H2S or precursor sulfoxy-anions to sulfate in environments containing Fe(III) or O2. This study examines the first step as a potential pathway for water oxygen incorporation into sulfate. We examined the structures and process of APS formation using B3LYP/6-31G(d,p) hybrid density functional theory, implemented in the Gaussian-03 program suite, to predict the potential for oxygen exchange. We conducted a set of in vitro, enzyme-catalyzed, APS formation experiments (with no further reduction to sulfite) to determine the degree of oxygen isotope exchange between the APS-sulfate and water. Triple-oxygen-isotope labeled water was used in the reactor solutions to monitor oxygen isotope exchange between water and APS sulfate. The formation and hydrolysis of APS were identified as potential steps for oxygen exchange with water to occur. Quantum chemical modeling indicates that the combination of sulfate with ATP has effects on bond strength and symmetry of the sulfate. However, these small effects impart little influence on the integrity of the SO42- tetrahedron due to the high activation energy required for

  5. Density functional simulation of resonant inelastic X-ray scattering experiments in liquids: acetonitrile.

    Science.gov (United States)

    Niskanen, Johannes; Kooser, Kuno; Koskelo, Jaakko; Käämbre, Tanel; Kunnus, Kristjan; Pietzsch, Annette; Quevedo, Wilson; Hakala, Mikko; Föhlisch, Alexander; Huotari, Simo; Kukk, Edwin

    2016-09-21

    In this paper we report an experimental and computational study of liquid acetonitrile (H 3 C-C[triple bond, length as m-dash]N) by resonant inelastic X-ray scattering (RIXS) at the N K-edge. The experimental spectra exhibit clear signatures of the electronic structure of the valence states at the N site and incident-beam-polarization dependence is observed as well. Moreover, we find fine structure in the quasielastic line that is assigned to finite scattering duration and nuclear relaxation. We present a simple and light-to-evaluate model for the RIXS maps and analyze the experimental data using this model combined with ab initio molecular dynamics simulations. In addition to polarization-dependence and scattering-duration effects, we pinpoint the effects of different types of chemical bonding to the RIXS spectrum and conclude that the H 2 C-C[double bond, length as m-dash]NH isomer, suggested in the literature, does not exist in detectable quantities. We study solution effects on the scattering spectra with simulations in liquid and in vacuum. The presented model for RIXS proved to be light enough to allow phase-space-sampling and still accurate enough for identification of transition lines in physical chemistry research by RIXS.

  6. Extended abstract: ergodic magnetic limiter experiments on TEXT with a 7/3 resonance

    International Nuclear Information System (INIS)

    deGrassie, J.S.; Ohyabu, N.; Brooks, N.H.

    1984-05-01

    The ergodic magnetic limiter coils on TEXT have been reconfigured to produce the primary helical perturbation resonance at m = 7 / n = 3. The experiments continue to demonstrate that the weak resonant perturbations modify the edge conditions in keeping with model predictions. We observe a reduction in the intrinsic impurity levels accompanying the helical current pulse, presumably the result of a reduction in the electron temperature in the edge. Heat follows the perturbed field lines to the limiter, generating heat load patterns which reflect the geometry of a magnetic island - limiter intersection. A strong spatial modulation of the electron density in the scrape-off-layer also reflects the helical mode structure

  7. Experiments on resonator concept of plasma wakefield accelerator driven by a train of relativistic electron bunches

    International Nuclear Information System (INIS)

    Kiselev, V.A.; Linnik, A.F.; Mirny, V. I; Onishchenko, I.N.; Uskov, V.V.

    2008-01-01

    The experimental installation was elaborated to increase plasma wakefield amplitude by means of using plasma resonator that allows all bunches of the train to participate in wakefield build-up contrary to waveguide case, in which due to group velocity effect only a part of the bunches participates. Experiments on plasma producing with resonant density, at which a coincidence of the plasma frequency and bunch repetition frequency is provided, are carried out. The first results of the measurements of beam energy loss on plasma wakefield excitation and energy gain by accelerated electrons are presented

  8. Simulation of triple coincidences in PET

    International Nuclear Information System (INIS)

    Cal-González, J; Herranz, E; Vicente, E; Udias, J M; Lage, E; Dave, S R; Parot, V; Herraiz, J L; Moore, S C; Park, M-A

    2015-01-01

    Although current PET scanners are designed and optimized to detect double coincidence events, there is a significant amount of triple coincidences in any PET acquisition. Triple coincidences may arise from causes such as: inter-detector scatter (IDS), random triple interactions (R T ), or the detection of prompt gamma rays in coincidence with annihilation photons when non-pure positron-emitting radionuclides are used (β + γ events). Depending on the data acquisition settings of the PET scanner, these triple events are discarded or processed as a set of double coincidences if the energy of the three detected events is within the scanner’s energy window. This latter option introduces noise in the data, as at most, only one of the possible lines-of-response defined by triple interactions corresponds to the line along which the decay occurred. Several novel works have pointed out the possibility of using triple events to increase the sensitivity of PET scanners or to expand PET imaging capabilities by allowing differentiation between radiotracers labeled with non-pure and pure positron-emitting radionuclides. In this work, we extended the Monte Carlo simulator PeneloPET to assess the proportion of triple coincidences in PET acquisitions and to evaluate their possible applications. We validated the results of the simulator against experimental data acquired with a modified version of a commercial preclinical PET/CT scanner, which was enabled to acquire and process triple-coincidence events. We used as figures of merit the energy spectra for double and triple coincidences and the triples-to-doubles ratio for different energy windows and radionuclides. After validation, the simulator was used to predict the relative quantity of triple-coincidence events in two clinical scanners assuming different acquisition settings. Good agreement between simulations and preclinical experiments was found, with differences below 10% for most of the observables considered. For

  9. Triple-orifice valve repair in severe Barlow disease with multiple-jet mitral regurgitation: report of mid-term experience.

    Science.gov (United States)

    Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto

    2013-09-10

    Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Cavity QED experiments with a whispering-gallery-mode bottle resonator

    International Nuclear Information System (INIS)

    O'Shea, D.

    2013-01-01

    The interaction of a two-level atom with a single mode of the quantized electromagnetic field constitutes one of the most fundamental systems investigated in quantum optics. We have pursued such an investigation where rubidium atoms are strongly coupled to the modes of a whispering-gallery-mode (WGM) resonator that is itself interfaced with an optical fiber. In order to facilitate studies of this atom-light interaction, an experimental apparatus was constructed around a novel type of WGM resonator developed in our group. The spectral and spatial mode structure of this resonator yield an intriguing atom-light response arising principally from the existence of two frequency-degenerate modes. This thesis reports on high resolution experiments studying the transmission and reflection spectra of modes with a high quality factor (Q=10 7 -10 8 ) in our WGM resonator. Light is coupled into and out of WGMs by frustrated total internal reflection using an optical nanofiber. The atom-light interaction is facilitated by an atomic fountain that delivers a cloud of atoms to the location of the resonator. At random moments, single-atoms are clearly observed transiting the evanescent field of the resonator modes with a transit time of a few microseconds. A high-speed experimental control system was developed to firstly detect the coupling of individual atoms to the resonator and secondly to perform time-resolved spectroscopy on the strongly coupled atom-resonator system. Spectral measurements clearly resolve an atom-induced change in the resonant transmission of the coupled system (65% absolute change) that is much larger than predicted in the standard Jaynes-Cummings model (25% absolute change) and that has thus far not been observed. To gain further insight, we experimentally explored the properties of the interaction and performed supporting simulations. Spectroscopy was performed on the atom-resonator system using two nanofibers to in- and out-couple light for probing

  11. Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil

    OpenAIRE

    Bebout, William Roach

    1989-01-01

    Over the past ten to fifteen years the area of Nuclear Magnetic Resonance (NMR) Spectroscopy has seen tremendous growth. For example, in conjunction with multiple quantum NMR, molecular structural mapping of a compound can be easily performed in a two dimensional (2D) experiment. However, only two kinds of detector coils have been typically used in NMR studies. These are the solenoid coil and the Helmholtz coil. The solenoid coil was very popular with the permanent and e...

  12. Examination of total cross section resonance structure of niobium and silicon in neutron transmission experiments

    Science.gov (United States)

    Andrianova, Olga; Lomakov, Gleb; Manturov, Gennady

    2017-09-01

    The neutron transmission experiments are one of the main sources of information about the neutron cross section resonance structure and effect in the self-shielding. Such kind of data for niobium and silicon nuclides in energy range 7 keV to 3 MeV can be obtained from low-resolution transmission measurements performed earlier in Russia (with samples of 0.027 to 0.871 atom/barn for niobium and 0.076 to 1.803 atom/barn for silicon). A significant calculation-to-experiment discrepancy in energy range 100 to 600 keV and 300 to 800 keV for niobium and silicon, respectively, obtained using the evaluated nuclear data library ROSFOND, were found. The EVPAR code was used for estimation the average resonance parameters in energy range 7 to 600 keV for niobium. For silicon a stochastic optimization method was used to modify the resolved resonance parameters in energy range 300 to 800 keV. The improved ROSFOND evaluated nuclear data files were tested in calculation of ICSBEP integral benchmark experiments.

  13. Experiments on two-resonator circuit quantum electrodynamics. A superconducting quantum switch

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Elisabeth Christiane Maria

    2013-05-29

    The field of cavity quantum electrodynamics (QED) studies the interaction between light and matter on a fundamental level. In typical experiments individual natural atoms are interacting with individual photons trapped in three-dimensional cavities. Within the last decade the prospering new field of circuit QED has been developed. Here, the natural atoms are replaced by artificial solid state quantum circuits offering large dipole moments which are coupled to quasi-onedimensional cavities providing a small mode volume and hence a large vacuum field strength. In our experiments Josephson junction based superconducting quantum bits are coupled to superconducting microwave resonators. In circuit QED the number of parameters that can be varied is increased and regimes that are not accessible using natural atoms can be entered and investigated. Apart from design flexibility and tunability of system parameters a particular advantage of circuit QED is the scalability to larger system size enabled by well developed micro- and nanofabrication tools. When scaling up the resonator-qubit systems beyond a few coupled circuits, the rapidly increasing number of interacting subsystems requires an active control and directed transmission of quantum signals. This can, for example, be achieved by implementing switchable coupling between two microwave resonators. To this end, a superconducting flux qubit is used to realize a suitable coupling between two microwave resonators, all working in the Gigahertz regime. The resulting device is called quantum switch. The flux qubit mediates a second order tunable and switchable coupling between the resonators. Depending on the qubit state, this coupling can compensate for the direct geometric coupling of the two resonators. As the qubit may also be in a quantum superposition state, the switch itself can be ''quantum'': it can be a superposition of ''on'' and ''off''. This work

  14. Experiments on two-resonator circuit quantum electrodynamics. A superconducting quantum switch

    International Nuclear Information System (INIS)

    Hoffmann, Elisabeth Christiane Maria

    2013-01-01

    The field of cavity quantum electrodynamics (QED) studies the interaction between light and matter on a fundamental level. In typical experiments individual natural atoms are interacting with individual photons trapped in three-dimensional cavities. Within the last decade the prospering new field of circuit QED has been developed. Here, the natural atoms are replaced by artificial solid state quantum circuits offering large dipole moments which are coupled to quasi-onedimensional cavities providing a small mode volume and hence a large vacuum field strength. In our experiments Josephson junction based superconducting quantum bits are coupled to superconducting microwave resonators. In circuit QED the number of parameters that can be varied is increased and regimes that are not accessible using natural atoms can be entered and investigated. Apart from design flexibility and tunability of system parameters a particular advantage of circuit QED is the scalability to larger system size enabled by well developed micro- and nanofabrication tools. When scaling up the resonator-qubit systems beyond a few coupled circuits, the rapidly increasing number of interacting subsystems requires an active control and directed transmission of quantum signals. This can, for example, be achieved by implementing switchable coupling between two microwave resonators. To this end, a superconducting flux qubit is used to realize a suitable coupling between two microwave resonators, all working in the Gigahertz regime. The resulting device is called quantum switch. The flux qubit mediates a second order tunable and switchable coupling between the resonators. Depending on the qubit state, this coupling can compensate for the direct geometric coupling of the two resonators. As the qubit may also be in a quantum superposition state, the switch itself can be ''quantum'': it can be a superposition of ''on'' and ''off''. This work presents the theoretical background, the fabrication techniques and

  15. Circular waveguide systems for electron-cyclotron-resonant heating of the tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Felker, B.; Calderon, M.O.; Chargin, A.K.

    1983-01-01

    Extensive use of electron cyclotron resonant heating (ECRH) in the Tandem Mirror Experiment-Upgrade (TMX-U) requires continuous development of components to improve efficiency, increase reliability, and deliver power to new locations with respect to the plasma. We have used rectangular waveguide components on the experiment and have developed, tested, and installed circular waveguide components. We replaced the rectangular with the circular components because of the greater transmission efficiency and power-handling capability of the circular ones. Design, fabrication, and testing of all components are complete for all systems. In this paper we describe the design criteria for the system

  16. MCRTOF, Multiple Scattering of Resonance Region Neutron in Time of Flight Experiments

    International Nuclear Information System (INIS)

    Ohkubo, Mako

    1984-01-01

    1 - Description of program or function: Multiple scattering of neutrons in the resonance energy region impinging on a disk with an arbitrary angle. 2 - Method of solution: The Monte Carlo method is employed to simulate the path of an incident neutron in a medium for which macroscopic cross sections are determined by resonance parameters. By tracing a large number of neutrons, probabilities for capture, transmission, front-face scattering, rear-face scattering and side-face scattering are determined and printed out as function of incident neutron energy. Optionally, the distribution of capture locations in the disk can be printed. The incident neutron energy is swept to fit a situation as encountered in time-of-flight experiments. 3 - Restrictions on the complexity of the problem: The cross section file is constructed from input resonance parameters with a single- level Breit-Wigner formula. The following restrictions and simplifications apply: - The maximum number of resonances is five. - Reactions other than capture and scattering are neglected. - The angular scattering distribution in the center-of-mass system is assumed to be uniform. - Chemical binding effects are neglected

  17. Frequency tripling with multimode-lasers

    International Nuclear Information System (INIS)

    Langer, H.; Roehr, H.; Wrobel, W.G.

    1978-10-01

    The presence of different modes with random phases in a laser beam leads to fluctuations in nonlinear optical interactions. This paper describes the influence of the linewidth of a dye laser on the generation of intensive Lyman-alpha radiation by frequency tripling. Using this Lyman-alpha source for resonance scattering on strongly doppler-broadened lines in fusion plasmas the detection limit of neutral hydrogen is nearly two orders higher with the multimode than the singlemode dye laser. (orig.) [de

  18. Resonator QED experiments with single {sup 40}Ca{sup +} ions; Resonator-QED-Experimente mit einzelnen {sup 40}Ca{sup +}-Ionen

    Energy Technology Data Exchange (ETDEWEB)

    Lange, B.

    2006-12-20

    Combining an optical resonator with an ion trap provides the possibility for QED experiments with single or few particles interacting with a single mode of the electro-magnetic field (Cavity-QED). In the present setup, fluctuations in the count rate on a time scale below 30 seconds were purely determined by the photon statistics due to finite emission and detection efficiency, whereas a marginal drift of the system was noticeable above 200 seconds. To find methods to increase the efficiency of the photon source, investigations were conducted and experimental improvements of the setup implemented in the frame of this thesis. Damping of the resonator field and coupling of ion and field were considered as the most important factors. To reduce the damping of the resonator field, a resonator with a smaller transmissivity of the output mirror was set up. The linear trap used in the experiment allows for the interaction of multiple ions with the resonator field, so that more than one photon may be emitted per pump pulse. This was investigated in this thesis with two ions coupled to the resonator. The cross correlation of the emitted photons was measured with the Hanbury Brown-Twiss method. (orig.)

  19. You'll never crawl alone: Neurophysiological evidence for experience-dependent motor resonance in infancy

    DEFF Research Database (Denmark)

    van Elk, Michiel; van Schie, Hein; Hunnius, Sabine

    2008-01-01

    Lately, neuroscience is showing a great interest in examining the functional and neural mechanisms which support action observation and understanding. Recent studies have suggested that our motor skills crucially affect the way in which we perceive the actions generated by others, by showing...... stronger motor resonance for observation of actions that are established in one's motor repertoire. In the present study we extend previous findings that were based on expert motor skills in adults to the natural development of actions in infants. To investigate the effect of natural motor experience...... on motor resonance during action observation, 14- to 16-month-old infants' EEG was recorded during observation of action videos. Stronger mu- and betadesynchronizations were found for observation of crawling compared to walking videos and the size of the effect was strongly related to the infant's own...

  20. Angular correlation experiments for the study of giant multipole resonances and currents of the second kind in atomic nuclei

    International Nuclear Information System (INIS)

    1986-03-01

    The project dealt with angular correlation experiments for the study of giant multipole resonances and currents of the second kind in atomic nuclei. Both partial projects were worked in the period of the report. (orig.) [de

  1. Use of movable high-field-strength intraoperative magnetic resonance imaging with awake craniotomies for resection of gliomas: preliminary experience.

    LENUS (Irish Health Repository)

    Leuthardt, Eric C

    2011-07-01

    Awake craniotomy with electrocortical mapping and intraoperative magnetic resonance imaging (iMRI) are established techniques for maximizing tumor resection and preserving function, but there has been little experience combining these methodologies.

  2. Combination of results from the ATLAS and CMS experiments on anomalous triple gauge couplings in ZZ production from pp collisions at a centre-of-mass energy of 7 TeV at the LHC

    CERN Document Server

    CMS and ATLAS Collaborations

    2016-01-01

    A procedure is presented to combine data from the ATLAS and CMS experiments on ZZ production to obtain constraints on anomalous neutral triple gauge boson couplings. Statistical and systematic uncertainties and their correlations are taken into account. Data from pp collisions at a center-of-mass energy of 7 TeV delivered by the LHC are used. The datasets correspond to integrated luminosities of $4.6$ and $5.0~\\mathrm{fb}^{-1}$ for ATLAS and CMS, respectively. The combination is performed in the fully leptonic decay channels $\\mathrm{ZZ} \\to \\ell^+ \\ell^- \

  3. Measurement of triple-gauge-boson couplings in the experiment ALEPH and at LEP; Mesure des couplages a trois bosons dans l'experience ALEPH et au LEP

    Energy Technology Data Exchange (ETDEWEB)

    Bruneliere, R

    2003-04-01

    Precise measurements at LEP1 and SLD dramatically confirm the Standard Model predictions. Nevertheless, the most crucial consequence of a non-Abelian gauge theory, namely the specific form of the self-couplings of the W, Z and {gamma} was poorly tested. W pair production at LEP2 was a unique opportunity to measure accurately both W boson parameters and its gauge couplings. This thesis presents a study of WW events reconstruction on one hand, and a measurement of the anomalous couplings on the other hand. A precise measurement of the W mass (accuracy {approx} 10{sup -4}) is a major goal of the LEP2 program. The reconstruction of W mass disintegration products, used for this measurement, is very sensitive to the simulation defaults: an essential task is to understand and minimize their effects. This work presents a detailed study of the electromagnetic showers simulation in ALEPH. From this study, a new event reconstruction is proposed, which is tested on the LEP energy measurement obtained from Z return process. Triple gauge-boson couplings are measured from the data collected with the ALEPH detector between 1997 and 2000. Then, results are combined with the other three LEP experiments. This measurement directly confirms the non-Abelian nature of the electroweak sector. No deviation from the Standard Model is observed. (author)

  4. Analysis of Current-mode Detectors For Resonance Detection In Neutron Optics Time Reversal Symmetry Experiment

    Science.gov (United States)

    Forbes, Grant; Noptrex Collaboration

    2017-09-01

    One of the most promising explanations for the observed matter-antimatter asymmetry in our universe is the search for new sources of time-reversal (T) symmetry violation. The current amount of violation seen in the kaon and B-meson systems is not sufficient to describe this asymmetry. The Neutron Optics Time Reversal Experiment Collaboration (NOPTREX) is a null test for T violation in polarized neutron transmission through a polarized 139La target. Due to the high neutron flux needed for this experiment, as well as the ability to effectively subtract background noise, a current-mode neutron detector that can resolve resonances at epithermal energies has been proposed. In order to ascertain if this detector design would meet the requirements for the eventual NOPTREX experiment, prototypical detectors were tested at the NOBORU beam at the Japan Proton Accelerator Research Complex (JPARC) facility. Resonances in In and Ta were measured and the collected data was analyzed. This presentation will describe the analysis process and the efficacy of the detectors will be discussed. Department of Energy under Contract DE-SC0008107, UGRAS Scholarship.

  5. First measurement of isoscalar giant resonances in a stored-beam experiment

    Directory of Open Access Journals (Sweden)

    J.C. Zamora

    2016-12-01

    Full Text Available A new technique developed for measuring nuclear reactions at low momentum transfer with stored beams in inverse kinematics was successfully used to study isoscalar giant resonances. The experiment was carried out at the experimental heavy-ion storage ring (ESR at the GSI facility using a stored 58Ni beam at 100 MeV/u and an internal helium gas-jet target. In these measurements, inelastically scattered α-recoils at very forward center-of-mass angles (θcm≤1.5° were detected with a dedicated setup, including ultra-high vacuum compatible detectors. Experimental results indicate a dominant contribution of the isoscalar giant monopole resonance at this very forward angular range. It was found that the monopole contribution exhausts 79−11+12% of the energy-weighted sum rule (EWSR, which agrees with measurements performed in normal kinematics. This opens up the opportunity to investigate the giant resonances in a large domain of unstable and exotic nuclei in the near future. It is a fundamental milestone towards new nuclear reaction studies with stored ion beams.

  6. Excitation of the ionospheric Alfvén resonator from the ground: Theory and experiments

    Science.gov (United States)

    Streltsov, A. V.; Chang, C.-L.; Labenski, J.; Milikh, G.; Vartanyan, A.; Snyder, A. L.

    2011-10-01

    We report results from numerical and experimental studies of the excitation of ULF shear Alfvén waves inside the ionospheric Alfvén resonator (IAR) by heating the ionosphere with powerful HF waves launched from the High Frequency Active Auroral Research Program (HAARP) facility in Alaska. Numerical simulations of the two-fluid MHD model describing IAR in a dipole magnetic field geometry with plasma parameters taken from the observations at HAARP during the October-November 2010 experimental campaign reveal that the IAR quality is higher during nighttime conditions, when the ionospheric conductivity is very low. Simulations also reveal that the resonance wave cannot be identified from the magnetic measurements on the ground or at an altitude above 600 km because the magnetic field in this wave has nodes on both ends of the resonator, and the best way to detect IAR modes is by measuring the electric field on low Earth orbit satellites. These theoretical predictions are in good, quantitative agreement with results from observations: In particular, (1) observations from the ground-based magnetometer at the HAARP site demonstrate no significant difference in the amplitudes of the magnetic field generated by HAARP in the frequency range from 0 to 5 Hz, and (2) the DEMETER satellite detected the electric field of the IAR first harmonic at an altitude of 670 km above HAARP during the heating experiment.

  7. Magnetic resonance spectroscopy imaging in the diagnosis of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Melo, Homero Jose de Farias e; Abdala, Nitamar; Goldman, Suzan Menasce; Szejnfeld, Jacob

    2009-01-01

    Objective: to report an experiment involving the introduction of a protocol utilizing commercially available three-dimensional 1H magnetic resonance spectroscopy imaging (3D 1H MRSI) method in patients diagnosed with prostatic tumors under suspicion of neoplasm. Materials and methods: forty-one patients in the age range between 51 and 80 years (mean, 67 years) were prospectively evaluated. The patients were divided into two groups: patients with one or more biopsies negative for cancer and high specific-prostatic antigen levels (group A), and patients with cancer confirmed by biopsy (group B). The determination of the target area (group A) or the known cancer extent (group B) was based on magnetic resonance imaging and MRSI studies. Results: the specificity of MRSI in the diagnosis of prostate cancer was lower than the specificity reported in the literature (about 47%). On the other hand, for tumor staging, it corresponded to the specificity reported in the literature. Conclusion: the introduction and standardization of 3D 1H MRSI has allowed the obtention of a presumable diagnosis of prostate cancer, by a combined analysis of magnetic resonance imaging and metabolic data from 3D 1H MRSI. (author)

  8. Limiting effects on laser compression by resonant backward Raman scattering in modern experiments

    International Nuclear Information System (INIS)

    Yampolsky, Nikolai A.; Fisch, Nathaniel J.

    2011-01-01

    Through resonant backward Raman scattering, the plasma wave mediates the energy transfer between long pump and short seed laser pulses. These mediations can result in pulse compression at extraordinarily high powers. However, both the overall efficiency of the energy transfer and the duration of the amplified pulse depend upon the persistence of the plasma wave excitation. At least with respect to the recent state-of-the-art experiments, it is possible to deduce that at present the experimentally realized efficiency of the amplifier is likely constrained mainly by two effects, namely, the pump chirp and the plasma wave wavebreaking.

  9. Triple aldose reductase/α-glucosidase/radical scavenging high-resolution profiling combined with high-performance liquid chromatography – high-resolution mass spectrometry – solid-phase extraction – nuclear magnetic resonance spectroscopy for identification of antidiabetic constituents in crude, extract of Radix Scutellariae

    DEFF Research Database (Denmark)

    Tahtah, Yousof; Kongstad, Kenneth Thermann; Wubshet, Sileshi Gizachew

    2015-01-01

    high-performance liquid chromatography – high-resolution mass spectrometry – solid-phase extraction – nuclear magnetic resonance spectroscopy. The only α-glucosidase inhibitor was baicalein, whereas main aldose reductase inhibitors in the crude extract were baicalein and skullcapflavone II, and main....../α-glucosidase/radical scavenging high-resolution inhibition profile - allowing proof of concept with Radix Scutellariae crude extract as a polypharmacological herbal drug. The triple bioactivity high-resolution profiles were used to pinpoint bioactive compounds, and subsequent structure elucidation was performed with hyphenated...

  10. Confirmation of the Z(4430)- resonance and other exotic meson results from the LHCb experiment

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHCb experiment at CERN has recently confirmed the existence of the exotic Z(4430)- state first observed by the Belle experiment in 2008. Its quantum numbers have been measured and the resonant nature of this state has been demonstrated for the first time. As it is charged, the Z(4430)- cannot be classified as a conventional charmonium (ccbar) state, making it a candidate for an exotic resonance composed of four quarks (ccbar udbar). This talk will outline the history of the Z(4430)-, its possible interpretations and describe how the signature of this exotic state can be extracted from the large sample of B0 -> psi(2S) K+pi- decays that LHCb has collected during Run-1 of the LHC. I will also describe recent LHCb results that probe the nature of the exotic X(3872) particle and help to clarify our understanding of the f0(500) and f0(980) scalar mesons that have long thought to be four quark states.

  11. Resonant laser power build-up in ALPS-A 'light shining through a wall' experiment

    International Nuclear Information System (INIS)

    Ehret, Klaus; Frede, Maik; Ghazaryan, Samvel; Hildebrandt, Matthias; Knabbe, Ernst-Axel; Kracht, Dietmar; Lindner, Axel; List, Jenny; Meier, Tobias; Meyer, Niels; Notz, Dieter; Redondo, Javier; Ringwald, Andreas; Wiedemann, Guenter; Willke, Benno

    2009-01-01

    The ALPS Collaboration runs a 'light shining through a wall' (LSW) experiment to search for photon oscillations into 'weakly interacting sub-eV particles' (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical resonant cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run.

  12. Roads leading to roam. Role of triple fragmentation and of conical intersections in photochemical reactions: experiments and theory on methyl formate.

    Science.gov (United States)

    Tsai, Po-Yu; Chao, Meng-Hsuan; Kasai, Toshio; Lin, King-Chuen; Lombardi, Andrea; Palazzetti, Federico; Aquilanti, Vincenzo

    2014-02-21

    The exploration of alternative roads that open to molecules with sufficient energy to yield different products permits prediction and eventually control of the outcomes of chemical reactions. Advanced imaging techniques for monitoring laser-induced photodissociation are here combined with dynamical simulations, involving ample sets of classical trajectories generated on a quantum chemical potential energy surface. Methyl formate, HCOOCH3, is photodissociated at energies near the triple fragmentation threshold into H, CO and OCH3. Images of velocity and rotational distributions of CO exhibit signatures of alternative routes, such as those recently designated as transition-state vs. roaming-mediated. Furthermore, a demonstration of the triple fragmentation route is given, and also confirmed by H-atom product imaging and FTIR time-resolved spectra of the intermediate HCO radical. In addition, the relevance of nonadiabatic transitions promoted by a conical intersection is clarified by simulations as the privileged "reactivity funnel" of organic photochemistry, whereby the outcomes of molecular photoexcitation are delivered to electronic ground states.

  13. RITA: The reinvented triple axis spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mason, T.E. [Toronto Univ., ON (Canada). Dept. of Physics; Clausen, K.N.; Aeppli, G.; McMorrow, D.R.; Kjems, J.K. [Risoe National Lab., Roskilde (Denmark)

    1995-11-01

    Risoe National Laboratory was reported to be in the process of developing a new spectrometer design, RITA, based on the triple axis design. The spectrometer will attempt to incorporate more recent innovations such as multilayer supermirrors and microstrip proportional counters into a rethinking of the triple-axis spectrometer. By optimizing the beam optics, using supermirrors and extending the analyser to map regions of (Q, {omega}) space using an array of independently controllable pyrolytic graphite crystals focussed on an area detector, it was hoped that the efficiency of single-crystal inelastic experiments could be increased by as much as a factor of 20. 7 figs., 20 refs.

  14. Coherent Transport in a Linear Triple Quantum Dot Made from a Pure-Phase InAs Nanowire.

    Science.gov (United States)

    Wang, Ji-Yin; Huang, Shaoyun; Huang, Guang-Yao; Pan, Dong; Zhao, Jianhua; Xu, H Q

    2017-07-12

    A highly tunable linear triple quantum dot (TQD) device is realized in a single-crystalline pure-phase InAs nanowire using a local finger gate technique. The electrical measurements show that the charge stability diagram of the TQD can be represented by three kinds of current lines of different slopes and a simulation performed based on a capacitance matrix model confirms the experiment. We show that each current line observable in the charge stability diagram is associated with a case where a QD is on resonance with the Fermi level of the source and drain reservoirs. At a triple point where two current lines of different slopes move together but show anticrossing, two QDs are on resonance with the Fermi level of the reservoirs. We demonstrate that an energetically degenerated quadruple point at which all three QDs are on resonance with the Fermi level of the reservoirs can be built by moving two separated triple points together via sophistically tuning of energy levels in the three QDs. We also demonstrate the achievement of direct coherent electron transfer between the two remote QDs in the TQD, realizing a long-distance coherent quantum bus operation. Such a long-distance coherent coupling could be used to investigate coherent spin teleportation and superexchange effects and to construct a spin qubit with an improved long coherent time and with spin state detection solely by sensing the charge states.

  15. Almost convergence of triple sequences

    OpenAIRE

    Ayhan Esi; M.Necdet Catalbas

    2013-01-01

    In this paper we introduce and study the concepts of almost convergence and almost Cauchy for triple sequences. Weshow that the set of almost convergent triple sequences of 0's and 1's is of the first category and also almost everytriple sequence of 0's and 1's is not almost convergent.Keywords: almost convergence, P-convergent, triple sequence.

  16. Drop evaporation and triple line dynamics

    Science.gov (United States)

    Sobac, Benjamin; Brutin, David; Gavillet, Jerome; Université de Provence Team; Cea Liten Team

    2011-03-01

    Sessile drop evaporation is a phenomenon commonly came across in nature or in industry with cooling, paintings or DNA mapping. However, the evaporation of a drop deposited on a substrate is not completely understood due to the complexity of the problem. Here we investigate, with several nano-coating of the substrate (PTFE, SiOx, SiOc and CF), the influence of the dynamic of the triple line on the evaporation process. The experiment consists in analyzing simultaneously the motion of the triple line, the kinetics of evaporation, the internal thermal motion and the heat and mass transfer. Measurements of temperature, heat-flux and visualizations with visible and infrared cameras are performed. The dynamics of the evaporative heat flux appears clearly different depending of the motion of the triple line

  17. General classical and quantum-mechanical description of magnetic resonance: an application to electric-dipole-moment experiments

    Energy Technology Data Exchange (ETDEWEB)

    Silenko, Alexander J. [Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); Joint Institute for Nuclear Research, Bogoliubov Laboratory of Theoretical Physics, Dubna (Russian Federation)

    2017-05-15

    A general theoretical description of a magnetic resonance is presented. This description is necessary for a detailed analysis of spin dynamics in electric-dipole-moment experiments in storage rings. General formulas describing a behavior of all components of the polarization vector at the magnetic resonance are obtained for an arbitrary initial polarization. These formulas are exact on condition that the nonresonance rotating field is neglected. The spin dynamics is also calculated at frequencies far from resonance with allowance for both rotating fields. A general quantum-mechanical analysis of the spin evolution at the magnetic resonance is fulfilled and the full agreement between the classical and quantum-mechanical approaches is shown. Quasimagnetic resonances for particles and nuclei moving in noncontinuous perturbing fields of accelerators and storage rings are considered. Distinguishing features of quasimagnetic resonances in storage ring electric-dipole-moment experiments are investigated in detail. The exact formulas for the effect caused by the electric dipole moment are derived. The difference between the resonance effects conditioned by the rf electric-field flipper and the rf Wien filter is found and is calculated for the first time. The existence of this difference is crucial for the establishment of a consent between analytical derivations and computer simulations and for checking spin tracking programs. The main systematical errors are considered. (orig.)

  18. [Development of RF coil of permanent magnet mini-magnetic resonance imager and mouse imaging experiments].

    Science.gov (United States)

    Hou, Shulian; Xie, Huantong; Chen, Wei; Wang, Guangxin; Zhao, Qiang; Li, Shiyu

    2014-10-01

    In the development of radio frequency (RF) coils for better quality of the mini-type permanent magnetic resonance imager for using in the small animal imaging, the solenoid RF coil has a special advantage for permanent magnetic system based on analyses of various types.of RF coils. However, it is not satisfied for imaging if the RF coils are directly used. By theoretical analyses of the magnetic field properties produced from the solenoid coil, the research direction was determined by careful studies to raise further the uniformity of the magnetic field coil, receiving coil sensitivity for signals and signal-to-noise ratio (SNR). The method had certain advantages and avoided some shortcomings of the other different coil types, such as, birdcage coil, saddle shaped coil and phased array coil by using the alloy materials (from our own patent). The RF coils were designed, developed and made for keeled applicable to permanent magnet-type magnetic resonance imager, multi-coil combination-type, single-channel overall RF receiving coil, and applied for a patent. Mounted on three instruments (25 mm aperture, with main magnetic field strength of 0.5 T or 1.5 T, and 50 mm aperture, with main magnetic field strength of 0.48 T), we performed experiments with mice, rats, and nude mice bearing tumors. The experimental results indicated that the RF receiving coil was fully applicable to the permanent magnet-type imaging system.

  19. A small-angle camera for resonant scattering experiments at the storage ring DORIS

    International Nuclear Information System (INIS)

    Stuhrmann, H.B.; Gabriel, A.

    1983-01-01

    Resonant small-angle scattering is measured routinely in the wavelength range of 0.6 to 3.25 A with the instrument X15 at the storage ring DORIS. The monochromatic beam with a vertical offset of 1.22 m is achieved by a double monochromator system with a constant exit slit. The small-angle instrument allows for sample-detector distances between 0.37 and 7.33 m. A multiwire proportional counter with a sensitive area of 200 X 200 mm detects the scattered intensity with a spatial resolution of 2 X 2 mm. Its sensitivity can be adapted to the requirements of the experiment by activating a drift chamber of 8 cm depth at the back end of the detector. The performance of the instrument as a function of the wavelength is described. The energy resolution is about 1 eV at the L 3 absorption edge of caesium, as shown by the resonant scattering of ferritin in 30% CsCl solution. (Auth.)

  20. Resonant Wave Energy Converters: Small-scale field experiments and first full-scale prototype

    International Nuclear Information System (INIS)

    Arena, Felice; Fiamma, Vincenzo; Iannolo, Roberto; Laface, Valentina; Malara, Giovanni; Romolo, Alessandra; Strati Federica Maria

    2015-01-01

    The Resonant Wave Energy Converter 3 (REWEC3) is a device belonging to the family of Oscillating Water Columns (OWCs), that can convert the energy of incident waves into electrical energy via turbines. In contrast to classical OWCs, it incorporates a small vertical U-shaped duct to connect the water column to the open wave field. This article shows the results of a small-scale field experiment involving a REWEC3 designed for working with a 2 kW turbine. Then, the next experimental activity on a REWEC3 installed in the NOEL laboratory with the collaboration of ENEA, is presented. Finally, the first prototype of ReWEC3 under construction in Civitavecchia (Rome, Italy) is shown. The crucial features of the construction stage are discussed and some initial performances are provided. [it

  1. The design, fabrication, and testing of beryllium capsules for resonant ultrasound experiments

    International Nuclear Information System (INIS)

    Salazar, M.A.; Salzer, L.; Day, R.

    1999-01-01

    Inertial Confinement Fusion (ICF) ignition targets require smooth and well-characterized deuterium/tritium (DT) ice layers. Los Alamos is developing Resonant Ultrasound Spectroscopy (RUS) to measure the internal pressure in the targets at room temperature after filling with DT. RUS techniques also can detect and measure the amplitudes of low modal surface roughness perturbations of the target shell interior. The experiments required beryllium capsules with a nominal inside radius of 1 mm and a spherical outside radius of 3 mm. The capsules have various spherical harmonic contours up to mode 12 machined into their interior surfaces. The capsules are constructed from hemispheres using an epoxy adhesive and then filled to ∼270 atm with helium or deuterium gas. This paper describes the adhesive joint design, machining techniques, and interior geometry inspection techniques. It also describes the fixtures needed to assemble, fill, and pressure test the capsules

  2. Scoring inflammatory activity of the spine by magnetic resonance imaging in ankylosing spondylitis: a multireader experiment

    DEFF Research Database (Denmark)

    Lukas, Cédric; Braun, Jürgen; van der Heijde, Désirée

    2007-01-01

    = 10) and selected to cover a wide range of activity at baseline and change in activity, were presented electronically in a partial latin-square design to 9 experienced readers from different countries (Europe, Canada). Readers scored each set of MRI 3 times, using 3 different methods including...... the Ankylosing Spondylitis spine Magnetic Resonance Imaging-activity [ASspiMRI-a, grading activity (0-6) per vertebral unit in 23 units]; the Berlin modification of the ASspiMRI-a; and the Spondyloarthritis Research Consortium of Canada (SPARCC) scoring system, which scores the 6 vertebral units considered......) assessed by Z-scores was good and comparable among methods. CONCLUSION: This experiment demonstrates the feasibility of multiple-reader MRI scoring exercises for method comparison, provides evidence for the feasibility, reliability, sensitivity to change, and discriminatory capacity of all 3 tested scoring...

  3. The Relationships Among Brand Experience, Brand Resonance and Brand Loyalty in Experiential Marketing: Evidence from Smart phone in Taiwan

    OpenAIRE

    Shieh Hwai-Shuh; Lai Wei-Hsun

    2017-01-01

    Aim/purpose - The study aims to understand the contribution of the experiential events how to influence the brand loyalty while the consumer synchronized with brand under the brand resonance. Design/methodology/approach - The study combines Schmitt's five distinct experience 'modules' with the SEM method to explore the relationship among these five experience dimensions and brand experience, and applies the Keller's CBBE model to explore whether the experiential events that consumer participa...

  4. The TARC experiment (PS211): neutron-driven nuclear transmutation by adiabatic resonance crossing

    International Nuclear Information System (INIS)

    Revol, J.P.; Arnould, H.; Bompas, C.A.

    1999-01-01

    The main purpose of the TARC experiment is to demonstrate the possibility of using Adiabatic Resonance Crossing (ARC) to destroy efficiently Long-Lived Fission Fragments (LLFFs) in accelerator-driven systems and to validate a new simulation developed in the framework of the Energy Amplifier programme. An experimental set-up was installed in a CERN PS beam line to study how neutrons produced by spallation at relatively high energy (E n ≥1 MeV) slow down quasi adiabatically with almost flat isolethargic energy distribution and reach the capture resonance energy of an element to be transmuted where they will have a high probability of being captured. Precision measurements of energy and space distributions of spallation neutrons (using 2.5 GeV/c and 3.5 GeV/c protons) slowing down in a 3.3 m x 3.3 m x 3 m lead volume and of neutron capture rates of LLFFs 99 Tc, 129 I, and several other elements were performed. An appropriate formalism and appropriate computational tools necessary for the analysis and understanding of the data were developed and validated in detail. Our direct experimental observation of ARC demonstrates the possibility to destroy, in a parasitic mode, outside the Energy Amplifier core, large amounts of 99 Tc or 129 I at a rate exceeding the production rate, thereby making it practical to reduce correspondingly the existing stockpile of LLFFs. In addition, TARC opens up new possibilities for radioactive isotope production as an alternative to nuclear reactors, in particular for medical applications, as well as new possibilities for neutron research and industrial applications. (orig.)

  5. Triple axis spectrometers

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  6. Neutron resonance spins of 159Tb from experiments with polarized neutrons and polarized nuclei

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Ivanenko, A.I.; Lason', L.; Mareev, Yu.D.; Ovchinnikov, O.N.; Pikel'ner, L.B.; Sharapov, Eh.I.

    1976-01-01

    Spins of 27 neutron resonances of 159 Tb with energies up to 114 eV have been measured using polarized neutrons and nuclei beams in the modernized time-of-flight spectrometer of the IBR-30 pulse reator. The direct measurements of the terbium resonances spins performed using polarized neutrons reaffirm the conclusion that there are no unstationary effects in the behaviour of 159 Tb neutron resonances in the energy range

  7. Set up of a method for the adjustment of resonance parameters on integral experiments

    International Nuclear Information System (INIS)

    Blaise, P.

    1996-01-01

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.)

  8. Electron Spin Resonance Experiments on a Single Electron in Silicon Implanted with Phosphorous

    Science.gov (United States)

    Luhman, Dwight R.; Nguyen, K.; Tracy, L. A.; Carr, S.; Borchardt, J.; Bishop, N.; Ten Eyck, G.; Pluym, T.; Wendt, J.; Lilly, M. P.; Carroll, M. S.

    2015-03-01

    In this talk we will discuss the results of our ongoing experiments involving electron spin resonance (ESR) on a single electron in a natural silicon sample. The sample consists of an SET, defined by lithographic polysilicon gates, coupled to nearby phosphorous donors. The SET is used to detect charge transitions and readout the spin of the electron being investigated with ESR. The measurements were done with the sample at dilution refrigerator temperatures in the presence of a 1.3 T magnetic field. We will present data demonstrating Rabi oscillations of a single electron in this system as well as measurements of the coherence time, T2. We will also discuss our results using these and various other pulsing schemes in the context of a donor-SET system. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  9. Temperature dependence of the cosphi conductance in Josephson tunnel junctions determined from plasma resonance experiments

    International Nuclear Information System (INIS)

    Pedersen, N.F.; Soerensen, O.H.; Mygind, J.

    1978-01-01

    The microwave response at 9 GHz of Sn-O-Sn tunnel-junction current biased at zero dc voltage has been measured just below the critical temperature T/sub c/ of the Sn films. The temperature dependence of the cosphi conductance is determined from the resonant response at the junction plasma frequency f/sub p/ as the temperature is decreased from T/sub c/. We used three different schemes for observation of the plasma oscillations: (a) second-harmonic generation (excitation at approx. 4.5 GHz, f/sub p/ approx. 4.5 GHz); (b) mixing (excitations at approx. 9 and approx. 18 GHz, f/sub p/ approx. 9 GHz); (c) parametric half-harmonic oscillation (excitation at approx. 18 GHz, f/sub p/ approx. 9 GHz). Measurements were possible in two temperature intervals; 0.994 or = T/T/sub c/ > or = 0.930, with the result that as the temperature was decreased the cosphi amplitude first increased from about zero to positive values and then at lower temperatures decreased approaching -1 at the lowest temperatures of the experiment

  10. Ion Cyclotron Resonant Heating 2 X 1700 loop antenna for the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Brooksby, C.A.; Ferguson, S.W.; Molvik, A.W.; Barter, J.

    1986-01-01

    This paper reviews the mechanical design and improvements that have taken place on the loop type ion cyclotron resonance heating (ICRH) antennas that are located in the center cell region of the Tandem Mirror Experiment-Upgrade (TMX-U). A computer code (JASON) was used to design getter-shielded antenna supports that will hold off very high voltages (83 kV, DC) over a small insulator distance (2.25 inches) in a vacuum of 10/sup -5/ Torr. The authors also added corona shields on the ceramic-to-metal joints of the matching network capacitors. The system now operates reliably with peak radio frequency (RF) voltages of 40 kV at 2-to-4- MHz frequency and power levels up to 200 kW. The authors have just installed a new loop antenna in the east part of the central cell where the slot antenna was located. This antenna uses two of the slot's internal coax lines and the external matching network. The feedthroughs designed by Lawrence Livermore National Laboratory (LLNL) were replaced with two high-voltage RF feedthroughs designed by Oak Ridge National Laboratory (ORNL)

  11. Magnetic resonance neurography in the management of peripheral trigeminal neuropathy: experience in a tertiary care centre

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Brian; Chhabra, Avneesh [UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Zuniga, John R. [UT Southwestern Medical Center, Department of Oral and Maxillofacial Surgery, Surgery, Neurology and Neurotherapeutics, Dallas, TX (United States); Panchal, Neeraj [University of Pennsylvania, Department of Oral Maxillofacial Surgery, Philadelphia, PA (United States); Cheng, Jonathan [UT Southwestern Medical Center, Department of Plastic Surgery, Dallas, TX (United States)

    2016-10-15

    This tertiary care experience examines the utility of magnetic resonance neurography (MRN) in the management of peripheral trigeminal neuropathies. Seventeen patients with clinically suspected peripheral trigeminal neuropathies (inferior alveolar nerve and lingual nerve) were imaged uniformly with 1.5-T examinations. MRN results were correlated with clinical and surgical findings in operated patients and the impact on clinical management was assessed. Clinical findings included pain (14/17), sensory changes (15/17), motor changes (2/17) and palpable masses (3/17). Inciting events included prior dental surgery (12/17), trauma (1/17) and idiopathic incidents (4/17). Non-affected side nerves and trigeminal nerves in the intracranial and skull base course were normal in all cases. Final diagnoses on affected sides were nerve inflammation (4/17), neuroma in continuity (2/17), LN transection (1/17), scar entrapment (3/17), infectious granuloma (1/17), low-grade injuries (3/17) and no abnormality (3/17). Associated submandibular gland and sublingual gland oedema-like changes were seen in 3/17 cases because of parasympathetic effects. Moderate-to-excellent MRN-surgical correlation was seen in operated (8/17) patients, and neuroma and nerve transection were prospectively identified in all cases. MRN is useful for the diagnostic work-up of suspected peripheral trigeminal neuropathy patients with significant impact on clinical management and moderate-to-excellent correlation with intra-operative findings. (orig.)

  12. Magnetic resonance neurography in the management of peripheral trigeminal neuropathy: experience in a tertiary care centre

    International Nuclear Information System (INIS)

    Cox, Brian; Chhabra, Avneesh; Zuniga, John R.; Panchal, Neeraj; Cheng, Jonathan

    2016-01-01

    This tertiary care experience examines the utility of magnetic resonance neurography (MRN) in the management of peripheral trigeminal neuropathies. Seventeen patients with clinically suspected peripheral trigeminal neuropathies (inferior alveolar nerve and lingual nerve) were imaged uniformly with 1.5-T examinations. MRN results were correlated with clinical and surgical findings in operated patients and the impact on clinical management was assessed. Clinical findings included pain (14/17), sensory changes (15/17), motor changes (2/17) and palpable masses (3/17). Inciting events included prior dental surgery (12/17), trauma (1/17) and idiopathic incidents (4/17). Non-affected side nerves and trigeminal nerves in the intracranial and skull base course were normal in all cases. Final diagnoses on affected sides were nerve inflammation (4/17), neuroma in continuity (2/17), LN transection (1/17), scar entrapment (3/17), infectious granuloma (1/17), low-grade injuries (3/17) and no abnormality (3/17). Associated submandibular gland and sublingual gland oedema-like changes were seen in 3/17 cases because of parasympathetic effects. Moderate-to-excellent MRN-surgical correlation was seen in operated (8/17) patients, and neuroma and nerve transection were prospectively identified in all cases. MRN is useful for the diagnostic work-up of suspected peripheral trigeminal neuropathy patients with significant impact on clinical management and moderate-to-excellent correlation with intra-operative findings. (orig.)

  13. Measurements of radial profiles of ion cyclotron resonance heating on the Tandem Mirror Experiment-Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Falabella, S.

    1988-05-11

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawerence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). The probe has been inserted into the central-cell plasma at temperatures of 200 eV and densities of 3 x 10/sup 12/cm/sup /minus 3// without damage to the probe, or major degradation of the plasma. This analyzer has indicated an increase in ion temperature from near 20 eV before ICRH to near 150 eV during ICRH, with about 60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial intergral of n/sub i/T/sub i/ as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma is seen to vary from axially peaked, to nearly flat as the plasma conditions carried over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U. 62 refs., 63 figs., 7 tabs.

  14. Measurements of radial profiles of ion cyclotron resonance heating on the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Falabella, S.

    1988-01-01

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawerence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). The probe has been inserted into the central-cell plasma at temperatures of 200 eV and densities of 3 x 10 12 cm/sup /minus 3// without damage to the probe, or major degradation of the plasma. This analyzer has indicated an increase in ion temperature from near 20 eV before ICRH to near 150 eV during ICRH, with about 60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial intergral of n/sub i/T/sub i/ as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma is seen to vary from axially peaked, to nearly flat as the plasma conditions carried over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U. 62 refs., 63 figs., 7 tabs

  15. Measurements of radial profiles of ion cyclotron resonance heating on the tandem mirror experiment

    International Nuclear Information System (INIS)

    Falabella, S.

    1988-01-01

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawrence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). This analyzer indicates an increase in ion temperature from ∼20 eV before ICRH to ∼150 eV during ICRH, with ∼60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial integral of n i T i as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma potential is seen to vary from axially peaked, to nearly flat, as the plasma conditions varied over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U

  16. Harmonic analysis on triple spaces

    DEFF Research Database (Denmark)

    Danielsen, Thomas Hjortgaard

    In this thesis we study examples of triple spaces, both their structure theory, their invariant differential operators as well as analysis on them. The first major results provide us with some examples of triple spaces which are strongly spherical, i.e. satisfy some conditions reminiscent...

  17. Teaching Triple Science: GCSE Chemistry

    Science.gov (United States)

    Learning and Skills Network (NJ3), 2007

    2007-01-01

    The Department for Children, Schools and Families (DCSF) has contracted with the Learning and Skills Network to support awareness and take-up of Triple Science GCSEs through the Triple Science Support Programme. This publication provides an introduction to teaching and learning approaches for the extension topics within GCSE Chemistry. It…

  18. Survey of structures revealed in nucleon-nucleon scattering experiments and dibaryon resonances

    International Nuclear Information System (INIS)

    Hidaka, K.; Yokosawa, A.

    1979-01-01

    Structures appearing in various experimental data (particularly those with polarized beams) in nucleon-nucleon systems are reviewed. Evidence is presented for the existence of dibaryon resonances with an emphasis on a diproton resonance in 3 F 3 (J/sup P/ = 3 - ) state. 38 references

  19. The Relationships Among Brand Experience, Brand Resonance and Brand Loyalty in Experiential Marketing: Evidence from Smart phone in Taiwan

    Directory of Open Access Journals (Sweden)

    Shieh Hwai-Shuh

    2017-04-01

    Full Text Available Aim/purpose - The study aims to understand the contribution of the experiential events how to influence the brand loyalty while the consumer synchronized with brand under the brand resonance. Design/methodology/approach - The study combines Schmitt's five distinct experience 'modules' with the SEM method to explore the relationship among these five experience dimensions and brand experience, and applies the Keller's CBBE model to explore whether the experiential events that consumer participated could help the company build brand resonance through the brand experience delivering in the event. The study applies convenient sampling method and collects data through online questionnaire platform from April 12 to April 26, 2015. Deleting invalid or incomplete questionnaires, the study gets 204 valid samples from the total 229 respondents. Findings - The findings indicate that these five strategic experiences dimensions are positively related to the brand experience; the positive relationships among brand experience, brand resonance, and brand loyalty also exist. Research implications/limitations - The results of the study have some strategic implications for marketing practice. The findings point out that event marketing could be considered as an effective tool to enlarge customer base and to build brand loyalty. In the real world, the more event marketing adopts; the stronger brand experience is and the higher the effect on brand loyalty will be. Nevertheless, the study cannot provide specific constructive suggestion: how to design events to stimulate and create a strong, memorable brand experience. Originality/value/contribution - Few studies examine the effect of each brand experience dimensions on brand relationship, and this study fills this gap.

  20. Motion-Corrected Real-Time Cine Magnetic Resonance Imaging of the Heart: Initial Clinical Experience.

    Science.gov (United States)

    Rahsepar, Amir Ali; Saybasili, Haris; Ghasemiesfe, Ahmadreza; Dolan, Ryan S; Shehata, Monda L; Botelho, Marcos P; Markl, Michael; Spottiswoode, Bruce; Collins, Jeremy D; Carr, James C

    2018-01-01

    Free-breathing real-time (RT) imaging can be used in patients with difficulty in breath-holding; however, RT cine imaging typically experiences poor image quality compared with segmented cine imaging because of low resolution. Here, we validate a novel unsupervised motion-corrected (MOCO) reconstruction technique for free-breathing RT cardiac images, called MOCO-RT. Motion-corrected RT uses elastic image registration to generate a single heartbeat of high-quality data from a free-breathing RT acquisition. Segmented balanced steady-state free precession (bSSFP) cine images and free-breathing RT images (Cartesian, TGRAPPA factor 4) were acquired with the same spatial/temporal resolution in 40 patients using clinical 1.5 T magnetic resonance scanners. The respiratory cycle was estimated using the reconstructed RT images, and nonrigid unsupervised motion correction was applied to eliminate breathing motion. Conventional segmented RT and MOCO-RT single-heartbeat cine images were analyzed to evaluate left ventricular (LV) function and volume measurements. Two radiologists scored images for overall image quality, artifact, noise, and wall motion abnormalities. Intraclass correlation coefficient was used to assess the reliability of MOCO-RT measurement. Intraclass correlation coefficient showed excellent reliability (intraclass correlation coefficient ≥ 0.95) of MOCO-RT with segmented cine in measuring LV function, mass, and volume. Comparison of the qualitative ratings indicated comparable image quality for MOCO-RT (4.80 ± 0.35) with segmented cine (4.45 ± 0.88, P = 0.215) and significantly higher than conventional RT techniques (3.51 ± 0.41, P cine (1.51 ± 0.90, P = 0.088 and 1.23 ± 0.45, P = 0.182) were not different. Wall motion abnormality ratings were comparable among different techniques (P = 0.96). The MOCO-RT technique can be used to process conventional free-breathing RT cine images and provides comparable quantitative assessment of LV function and volume

  1. Preparation of a Cobalt(II) Cage: An Undergraduate Laboratory Experiment That Produces a ParaSHIFT Agent for Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Burns, Patrick J.; Tsitovich, Pavel B.; Morrow, Janet R.

    2016-01-01

    Laboratory experiments that demonstrate the effect of paramagnetic complexes on chemical shifts and relaxation times of protons are a useful way to introduce magnetic resonance spectroscopy (MRS) probes or magnetic resonance imaging (MRI) contrast agents. In this undergraduate inorganic chemistry experiment, a paramagnetic Co(II) cage complex is…

  2. Fine structure of the isoscalar giant quadrupole resonance from high-resolution inelastic proton scattering experiments

    International Nuclear Information System (INIS)

    Shevchenko, A.

    2005-02-01

    In the present work the phenomenon of fine structure in the region of the isoscalar giant quadrupole resonance in a number of heavy and medium-heavy nuclei is systematically investigated for the first time. High energy-resolution inelastic proton scattering experiments were carried out in September-October 2001 and in October 2003 at the iThemba LABS cyclotron facility in South Africa with an incident proton energy of 200 MeV. The obtained data with the energy resolution of triangle E 58 Ni, 89 Y, 90 Zr, 120 Sn, 142 Nd, 166 Er, 208 Pb), thereby establishing the global character of this phenomenon. Fine structure can be described using characteristic energy scales, appearing as a result of the decay of collective modes towards the compound nucleus through a hierarchy of couplings to complex degrees of freedom. For the extraction of the characteristic energy scales from the spectra an entropy index method and a novel technique based on the wavelet analysis are utilized. The global analysis of available data shows the presence of three groups of scales, according to their values. To the first group belong the scales with the values around and below 100 keV, which were detected in all the nuclei studied. The second group contains intermediate scales in the range of 100 keV to 1 MeV. These scales show large variations depending on the nuclear structure of the nucleus. The largest scales above 1 MeV are classified to the third group, describing the global structure of the resonance (the width). The interpretation of the observed scales is realized via the comparison with microscopic model calculations including the coupling of the initial one-particle-one-hole excitations to more complex configurations. A qualitative agreement of the experimentally observed scales with those obtained from the theoretical predictions supports the suggestion of the origin of fine structure from the coupling to the two-particle-two-hole states. However, quantitatively, large deviations are

  3. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  4. Low field magnetic resonance experiments in superfluid 3He--A

    International Nuclear Information System (INIS)

    Gully, W.J. Jr.

    1976-01-01

    Measurements of the longitudinal and transverse nuclear magnetic resonance signals have been made on the A phase of liquid 3 He. They were performed on a sample of 3 He self-cooled by the Pomeranchuk effect to the critical temperature of the superfluid at 2.7 m 0 K. The longitudinal resonance is a magnetic mode of the liquid excited by radio frequency magnetic fields applied in the direction of the static magnetic field. Frequency profiles of this resonance were indirectly obtained by contour techniques from signals recorded by sweeping the temperature. Its frequency is found to be related to the frequency shift of the transverse resonance in agreement with theoretical predictions for the ABM pairing state. Its linewidth also agrees with theoretical predictions based upon dissipative phenomena peculiar to the superfluid phase. An analysis of the linewidth of the longitudinal resonance yields a value for the quasiparticle collision time. Transverse NMR lines were also studied. In low magnetic fields (20 Oersted) these lines were found to become extremely broad. This is shown to be a manifestation of the same collisional processes that broaden the longitudinal resonance lines. Also, the effects of various textures on the resonance lines are discussed, including the results of an attempt to create a single domain of 3 He with crossed electric and magnetic fields

  5. Moessbauer and magnetic resonance experiments on amorphous iron-silicon films

    International Nuclear Information System (INIS)

    Bansal, C.; Campbell, S.J.; Stewart, A.M.

    1982-01-01

    Moessbauer measurements at room temperature and 4.2 K, and room temperature magnetic resonance measurments on a series of amorphous Fesub(x)Sisub(1-x) thin films (0.23 <= x <= 0.81) are presented. The concentration dependence of the isomer shifts and quadrupole splittings provides information on the nature of the local coordination in these amorphous materials. Analysis of the distributions of magnetic hyperfine splitting combined with the presence of multiple resonance in the magnetic resonance data indiates that magnetoanisotropy plays a dominant role in determining the magnetic behaviour of these films. (orig.)

  6. 13C-detected NMR experiments for automatic resonance assignment of IDPs and multiple-fixing SMFT processing

    International Nuclear Information System (INIS)

    Dziekański, Paweł; Grudziąż, Katarzyna; Jarvoll, Patrik; Koźmiński, Wiktor; Zawadzka-Kazimierczuk, Anna

    2015-01-01

    Intrinsically disordered proteins (IDPs) have recently attracted much interest, due to their role in many biological processes, including signaling and regulation mechanisms. High-dimensional 13 C direct-detected NMR experiments have proven exceptionally useful in case of IDPs, providing spectra with superior peak dispersion. Here, two such novel experiments recorded with non-uniform sampling are introduced, these are 5D HabCabCO(CA)NCO and 5D HNCO(CA)NCO. Together with the 4D (HACA)CON(CA)NCO, an extension of the previously published 3D experiments (Pantoja-Uceda and Santoro in J Biomol NMR 59:43–50, 2014. doi: 10.1007/s10858-014-9827-1 10.1007/s10858-014-9827-1 ), they form a set allowing for complete and reliable resonance assignment of difficult IDPs. The processing is performed with sparse multidimensional Fourier transform based on the concept of restricting (fixing) some of spectral dimensions to a priori known resonance frequencies. In our study, a multiple-fixing method was developed, that allows easy access to spectral data. The experiments were tested on a resolution-demanding alpha-synuclein sample. Due to superior peak dispersion in high-dimensional spectrum and availability of the sequential connectivities between four consecutive residues, the overwhelming majority of resonances could be assigned automatically using the TSAR program

  7. Basic principles of magnetic resonance imaging in cerebral ischemia and initial clinical experience

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Solomon, M.; Newton, T.H.; Weinstein, P.; Schmidley, J.; Norman, D.

    1985-01-01

    The basic principles of magnetic resonance imaging are described and their use in the investigation of cerebral ischemia outlined. A brief account is given of the clinical results of investigation to date

  8. Analysis and optimization of coupled windings in magnetic resonant wireless power transfer systems with orthogonal experiment method

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  9. Analysis and optimisation of coupled winding in magnetic resonant wireless power transfer systems with orthogonal experiment results

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual...... inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and inductance for PCB windings at high- frequency. The method can reduce the design iterations and thereby can get...... more optimal design results. The experiments verified the design objective of kQ as well as the design method effectively. In the optimal PCB windings prototype at operating frequency of 4 MHz, the kQ and the maximum efficiency are increased by about 12% and 4% respectively....

  10. Collagenolytic Matrix Metalloproteinase Activities toward Peptomeric Triple-Helical Substrates.

    Science.gov (United States)

    Stawikowski, Maciej J; Stawikowska, Roma; Fields, Gregg B

    2015-05-19

    Although collagenolytic matrix metalloproteinases (MMPs) possess common domain organizations, there are subtle differences in their processing of collagenous triple-helical substrates. In this study, we have incorporated peptoid residues into collagen model triple-helical peptides and examined MMP activities toward these peptomeric chimeras. Several different peptoid residues were incorporated into triple-helical substrates at subsites P3, P1, P1', and P10' individually or in combination, and the effects of the peptoid residues were evaluated on the activities of full-length MMP-1, MMP-8, MMP-13, and MMP-14/MT1-MMP. Most peptomers showed little discrimination between MMPs. However, a peptomer containing N-methyl Gly (sarcosine) in the P1' subsite and N-isobutyl Gly (NLeu) in the P10' subsite was hydrolyzed efficiently only by MMP-13 [nomenclature relative to the α1(I)772-786 sequence]. Cleavage site analysis showed hydrolysis at the Gly-Gln bond, indicating a shifted binding of the triple helix compared to the parent sequence. Favorable hydrolysis by MMP-13 was not due to sequence specificity or instability of the substrate triple helix but rather was based on the specific interactions of the P7' peptoid residue with the MMP-13 hemopexin-like domain. A fluorescence resonance energy transfer triple-helical peptomer was constructed and found to be readily processed by MMP-13, not cleaved by MMP-1 and MMP-8, and weakly hydrolyzed by MT1-MMP. The influence of the triple-helical structure containing peptoid residues on the interaction between MMP subsites and individual substrate residues may provide additional information about the mechanism of collagenolysis, the understanding of collagen specificity, and the design of selective MMP probes.

  11. The upgraded cold neutron triple-axis spectrometer FLEXX – enhanced capabilities by new instrumental options

    Directory of Open Access Journals (Sweden)

    Habicht Klaus

    2015-01-01

    Full Text Available The upgrade of the cold neutron triple axis spectrometer FLEXX, a work-horse instrument for inelastic neutron scattering matching the sample environment capabilities at Helmholtz-Zentrum Berlin, has been successfully accomplished. Experiments confirmed an order of magnitude gain in flux now allowing for intensity demanding options to be fully exploited at FLEXX. In this article, we describe the layout and design of two newly available FLEXX instrument options in detail. The new Heusler analyzer gives an increase of the detected polarized neutron flux due to its superior focusing properties, significantly improving the feasibility of future polarized and neutron resonance spin echo experiments. The MultiFLEXX option provides simultaneous access to large regions in wavevector and energy space for inelastic excitations thus adding mapping capabilities to the spectrometer.

  12. Two path transport measurements on a triple quantum dot

    Energy Technology Data Exchange (ETDEWEB)

    Rogge, Maximilian C.; Haug, Rolf J. [Institut fuer Festkoerperphysik, Leibniz Universitaet Hannover, Appelstr. 2, 30167 Hannover (Germany)

    2008-07-01

    We present a novel triple quantum dot device made with local anodic oxidation on a GaAs/AlGaAs heterostructure. The geometry provides two path transport via a three lead setup with each lead connected to one of the three quantum dots. In addition charge detection is implemented via a quantum point contact. One lead is used as a common source contact, the other two are used as two separate drain contacts with independent current measurement. Thus two paths are formed with two dots in each path. Along both paths serial transport is observed at the triple points of the two corresponding dots. With four side gates a wide tunability is given. Thus the system can be tuned in and out of triple dot resonances. When all three dots come into resonance, quadruple points are formed with simultaneous transport along both paths. The data are analysed in combined two colour plots and compared to the charge detection showing sets of three different lines, one for each dot. This way the two path setup allows to investigate the transition from double dot physics to triple dot physics.

  13. Search for jet-jet resonances in association with a leptonic W decay at the ATLAS experiment

    CERN Document Server

    Nuti, Francesco

    2012-01-01

    The analysis presented in this thesis addresses the study of two processes that share the same signature: the diboson $WW/WZ$ semileptonic decay and a jet-jet resonance with an invariant mass equal to $145~GeV/c^{2}$ produced in association with a $W$. In both cases the leptonic decay of the W is identified as an energetic electron or muon along with missing transverse energy forming a transverse mass~($M_{T}$) consistent with that one produced by the $W$ boson. The hadronically decaying $W/Z$ or the resonance at $145~GeV/c^{2}$ are searched in the jet-jet invariant mass distribution after a selection based on the event kinematics. The resonance at $145~GeV/c^{2}$ has been observed in April 2011 by the CDF detector at the Tevatron collider with a significance of $4.1$ standard deviations and is not predicted by Standard Model. Therefore it is important to determine the presence of this signal in other experiments and this thesis investigates the possibility to reveal the same resonance in data collected by ...

  14. Experiments at the GELINA facility for the validation of the self-indication neutron resonance densitometry technique

    Directory of Open Access Journals (Sweden)

    Rossa Riccardo

    2017-01-01

    Full Text Available Self-Indication Neutron Resonance Densitometry (SINRD is a passive non-destructive method that is being investigated to quantify the 239Pu content in a spent fuel assembly. The technique relies on the energy dependence of total cross sections for neutron induced reaction. The cross sections show resonance structures that can be used to quantify the presence of materials in objects, e.g. the total cross-section of 239Pu shows a strong resonance close to 0.3 eV. This resonance will cause a reduction of the number of neutrons emitted from spent fuel when 239Pu is present. Hence such a reduction can be used to quantify the amount of 239Pu present in the fuel. A neutron detector with a high sensitivity to neutrons in this energy region is used to enhance the sensitivity to 239Pu. This principle is similar to self-indication cross section measurements. An appropriate detector can be realized by surrounding a 239Pu-loaded fission chamber with appropriate neutron absorbing material. In this contribution experiments performed at the GELINA time-of-flight facility of the JRC at Geel (Belgium to validate the simulations are discussed. The results confirm that the strongest sensitivity to the target material was achieved with the self-indication technique, highlighting the importance of using a 239Pu fission chamber for the SINRD measurements.

  15. Measurement of K(892)*0 resonance production in Pb-Pb collisions with the ALICE experiment at the LHC

    CERN Document Server

    Bellini, Francesca

    The analysis of the K(892)*0 resonance production in Pb–Pb collisions at √sNN = 2.76 TeV with the ALICE detector at the LHC is presented. The analysis is motivated by the interest in the measurement of short-lived resonances production that can provide insights on the properties of the medium produced in heavy-ion collisions both during its partonic (Quark-Gluon Plasma) and hadronic phase. This particular analysis exploits particle identification of the ALICE Time-Of-Flight detector. The ALICE experiment is presented, with focus on the performance of the Time-Of-Flight system. The aspects of calibration and data quality controls are discussed in detail, while illustrating the excellent and very stable performance of the system in different collision environments at the LHC. A full analysis of the K*0 resonance production is presented: from the resonance reconstruction to the determination of the efficiency and the systematic uncertainty. The results show that the analysis strategy discussed is a valid too...

  16. Combination of results from the ATLAS and CMS experiments on anomalous triple gauge couplings in ZZ production from pp collisions at a centre-of-mass energy of 7 TeV at the LHC

    CERN Document Server

    ATLAS and CMS Collaborations

    2016-01-01

    A procedure is presented to combine data from the ATLAS and CMS experiments on $ZZ$ production to obtain constraints on anomalous neutral triple gauge boson couplings. Statistical and systematic uncertainties and their correlations are taken into account. Data from $pp$ collisions at a center-of-mass energy of 7 TeV delivered by the LHC are used. The datasets correspond to integrated luminosities of 4.6 and 5.0 $\\rm{fb^{−1}}$ for ATLAS and CMS, respectively. The combination is performed in the fully leptonic decay channels ZZ → 2l2ν (ATLAS) and ZZ → 4l (ATLAS, CMS). Combined limits on the coupling parameters are −0.010 < f4γ < 0.011, −0.0087 < f4Z < 0.0091, −0.011 < f5γ < 0.010, and −0.0091 < f5Z < 0.0089 at 95% C.L., where all other parameters are fixed to the standard model values. These results represent the first combined limits of the ATLAS and CMS collaborations for anomalous gauge boson couplings.

  17. Resonance effects in elastic cross sections for electron scattering on pyrimidine: Experiment and theory.

    Science.gov (United States)

    Regeta, Khrystyna; Allan, Michael; Winstead, Carl; McKoy, Vincent; Mašín, Zdeněk; Gorfinkiel, Jimena D

    2016-01-14

    We measured differential cross sections for elastic (rotationally integrated) electron scattering on pyrimidine, both as a function of angle up to 180(∘) at electron energies of 1, 5, 10, and 20 eV and as a function of electron energy in the range 0.1-14 eV. The experimental results are compared to the results of the fixed-nuclei Schwinger variational and R-matrix theoretical methods, which reproduce satisfactorily the magnitudes and shapes of the experimental cross sections. The emphasis of the present work is on recording detailed excitation functions revealing resonances in the excitation process. Resonant structures are observed at 0.2, 0.7, and 4.35 eV and calculations for different symmetries confirm their assignment as the X̃(2)A2, Ã(2)B1, and B̃(2)B1 shape resonances. As a consequence of superposition of coherent resonant amplitudes with background scattering the B̃(2)B1 shape resonance appears as a peak, a dip, or a step function in the cross sections recorded as a function of energy at different scattering angles and this effect is satisfactorily reproduced by theory. The dip and peak contributions at different scattering angles partially compensate, making the resonance nearly invisible in the integral cross section. Vibrationally integrated cross sections were also measured at 1, 5, 10 and 20 eV and the question of whether the fixed-nuclei cross sections should be compared to vibrationally elastic or vibrationally integrated cross section is discussed.

  18. Magnetic moment oscillation in ammonium perchlorate in a DC SQUID-based magnetic resonance experiment

    International Nuclear Information System (INIS)

    Montero, V.; Cernicchiaro, G.

    2008-01-01

    In this work we describe experimental results in which a DC SQUID (superconducting quantum interference device) is used as free induction decay detector. Measurements of a solid ammonium perchlorate (NH 4 ClO 4 ) sample were performed, in zero field, at 4.2 K. Unexpected magnetic moment oscillations were detected at 1.5 kHz. The computation of the magnetic fields suggests that the proton nuclear magnetic resonance may explain the measured resonance, considering reorientation of the ammonium group by quantum tunneling of protons and a magnetic proton dipole-dipole intermolecular interaction model

  19. Search for narrow baryon resonances (of masses through 3.4 and 5 GeV) through a π-p large angle elastic scattering formation experiment

    International Nuclear Information System (INIS)

    Chauveau, J.

    1981-01-01

    This work describes a search for narrow baryon resonances (of masses between 3.4 and 5 GeV) through a π - p large angle elastic scattering formation experiment. An optimization of the sensitivity of the experiment to detect resonances is obtained by the measurement of the central part of the angular distribution (/cos theta*/ -4 . The apparatus and data analysis are described in details. No narrow resonance has been found, the sensitivity of the experiment being characterized by a width GAMMA approximately equal to 1 MeV and an elasticity x approximately equal to 0.01. Finally, the differential cross section measurement is compared to some parton models [fr

  20. Resonant light power buildup in ALPS, a ''light shining through a wall''-experiment

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Tobias; Danzmann, Karsten; Willke, Benno [Max-Planck-Institut fuer Gravitationsphysik, Albert Einstein Institut (Germany); Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstrasse 38, D-30167 Hannover (Germany); Ehret, Klaus; Ghazaryan, Samvel; Knabbe, Axel; Lindner, Axel; List, Jenny; Meyer, Niels; Notz, Dieter; Redondo, Javier; Ringwald, Andreas [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Frede, Maik; Hildebrandt, Matthias [Laserzentrum Hannover e.V., Hollerithallee 8, D-30419 Hannover (Germany); Wiedemann, Guenter [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany)

    2009-07-01

    We report on the first successfull application of a new experimental technique to search for weakly interacting sub-eV particles (WISPs) coupling to photons. As part of the ALPS experiment located at DESY in Hamburg, this technique uses an optical resonator to enhance the power inside a HERA dipole magnet on the production side of a typical ''light shining through a wall''-experiment. We use a frequency doubled continuous-wave laser emitting 0.6 W of power at 532 nm that is stabilized to a linear optical resonator with 8 m length. On resonance we achieve a circulating power of 34 W within the magnet. With this we obtained sensitivities corresponding to a coupling strength of g{approx}5.10{sup -7} GeV{sup -1} for interactions of axion-like particles and photons. The experimental setup and possible improvements are described and compared with common experimental designs with pulsed lasers.

  1. Scoring sacroiliac joints by magnetic resonance imaging. A multiple-reader reliability experiment

    DEFF Research Database (Denmark)

    Landewe, Robert B.M.; Hermann, Kay Geert A; Van Der Heijde, Desiree M.F.M

    2005-01-01

    Magnetic resonance imaging (MRI) of the sacroiliac (SI) joints and the spine is increasingly important in the assessment of inflammatory activity and structural damage in clinical trials with patients with ankylosing spondylitis (AS). We investigated inter-reader reliability and sensitivity...

  2. Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent : Initial experience

    NARCIS (Netherlands)

    Bedaux, WLF; Hofman, MBM; Wielopolski, PA; de Cock, CC; Hoffmann, [No Value; Oudkerk, M; de Feyter, PJ; van Rossum, AC

    2002-01-01

    Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the

  3. Folded Fabry-Perot quasi-optical ring resonator diplexer Theory and experiment

    Science.gov (United States)

    Pickett, H. M.; Chiou, A. E. T.

    1983-01-01

    Performance of folded Fabry-Perot quasi-optical ring resonator diplexers with different geometries of reflecting surfaces is investigated both theoretically and experimentally. Design of optimum surface geometry for minimum diffraction, together with the figure of merit indicating improvement in performance, are given.

  4. Temperature dependence of the cosphi conductance in Josephson tunnel junctions determined from plasma resonance experiments

    DEFF Research Database (Denmark)

    Pedersen, Niels Falsig; Sørensen, O. H.; Mygind, Jesper

    1978-01-01

    The microwave response at 9 GHz of Sn-O-Sn tunnel-junction current biased at zero dc voltage has been measured just below the critical temperature Tc of the Sn films. The temperature dependence of the cosφ conductance is determined from the resonant response at the junction plasma frequency fp...

  5. Giant resonance spectroscopy of 40Ca with the (e,e'x) reaction (I): Experiments and overview of results

    International Nuclear Information System (INIS)

    Diesener, H.; Helm, U.; Neumann-Cosel, P. von; Richter, A.; Schrieder, G.; Stascheck, A.; Stiller, A.; Carter, J.

    2001-01-01

    The 40 Ca(e,e'x; x=p,α) reaction has been measured in the giant resonance excitation region for E x ≅8-26 MeV. The present article is the first out of three describing the experiments and giving an overview of the results. Data were taken at four momentum transfers in the range q=0.26-0.66 fm -1 . Angular correlations for decay to the ground state and low-lying states of 39 K and 36 Ar could be extracted as a function of excitation energy in 40 Ca. Excitation energy spectra integrated over the particle emission angle were generated for the various resolved decay channels. Comparisons of the giant resonance cross-section distributions with results using other electromagnetic or hadronic probes have been made and good agreement is found in most cases

  6. Numerical analysis of resonances induced by s wave neutrons in transmission time-of-flight experiments with a computer IBM 7094 II

    International Nuclear Information System (INIS)

    Corge, Ch.

    1969-01-01

    Numerical analysis of transmission resonances induced by s wave neutrons in time-of-flight experiments can be achieved in a fairly automatic way on an IBM 7094/II computer. The involved computations are carried out following a four step scheme: 1 - experimental raw data are processed to obtain the resonant transmissions, 2 - values of experimental quantities for each resonance are derived from the above transmissions, 3 - resonance parameters are determined using a least square method to solve the over determined system obtained by equalling theoretical functions to the correspondent experimental values. Four analysis methods are gathered in the same code, 4 - graphical control of the results is performed. (author) [fr

  7. Plasmon resonance in multilayer graphene nanoribbons

    DEFF Research Database (Denmark)

    Emani, Naresh Kumar; Wang, Di; Chung, Ting Fung

    2015-01-01

    Plasmon resonances in nanopatterned single-layer graphene nanoribbons (SL-GNRs), double-layer graphene nanoribbons (DL-GNRs) and triple-layer graphene nanoribbons (TL-GNRs) are studied experimentally using 'realistic' graphene samples. The existence of electrically tunable plasmons in stacked...... multilayer graphene nanoribbons was first experimentally verified by infrared microscopy. We find that the strength of the plasmonic resonance increases in DL-GNRs when compared to SL-GNRs. However, further increase was not observed in TL-GNRs when compared to DL-GNRs. We carried out systematic full......-wave simulations using a finite-element technique to validate and fit experimental results, and extract the carrier-scattering rate as a fitting parameter. The numerical simulations show remarkable agreement with experiments for an unpatterned SLG sheet, and a qualitative agreement for a patterned graphene sheet...

  8. Synchrobetatron resonances

    International Nuclear Information System (INIS)

    1977-03-01

    At the 1975 Particle Accelerator Conference it was reported that a class of resonances were observed in SPEAR II that had not appeared before in SPEAR I. While the existence of sideband resonances of the main betatron oscillation frequencies has been previously observed and analyzed, the resonances observed in SPEAR do not appear to be of the same variety. Experiments were performed at SPEAR to identify the mechanism believed to be the most likely explanation. Some of the current experimental knowledge and theoretical views on the source of these resonances are presented

  9. Scoring inflammatory activity of the spine by magnetic resonance imaging in ankylosing spondylitis: a multireader experiment

    DEFF Research Database (Denmark)

    Lukas, C; Braun, J; van der Heijde, D

    2007-01-01

    OBJECTIVE: Magnetic resonance imaging (MRI) of the spine is increasingly important in the assessment of inflammatory activity in clinical trials with patients with ankylosing spondylitis (AS). We investigated feasibility, inter-reader reliability, sensitivity to change, and discriminatory ability...... of 3 different scoring methods for MRI activity and change in activity of the spine in patients with AS. METHODS: Thirty sets of spinal MRI at baseline and after 24 weeks of followup, derived from a randomized clinical trial comparing a tumor necrosis factor (TNF)-blocking drug (n = 20) with placebo (n...... the Ankylosing Spondylitis spine Magnetic Resonance Imaging-activity [ASspiMRI-a, grading activity (0-6) per vertebral unit in 23 units]; the Berlin modification of the ASspiMRI-a; and the Spondyloarthritis Research Consortium of Canada (SPARCC) scoring system, which scores the 6 vertebral units considered...

  10. Measurement of collisional self broadening of atomic resonance lines in selective reflection experiment

    International Nuclear Information System (INIS)

    Papoyan, A.V.

    1998-01-01

    A method is developed to measure directly the collisional self broadening rate for a dense atomic vapor from selective reflection spectra. Experimental realization for the atomic D 1 and D 2 resonance lines of Rb confirms a validity of the proposed technique. The deflection of experimentally measured values is not more than 20% from theoretically predicted ones in the atomic number density range of 7· 10 16 - 7· 10 17 cm - 3 . 10 refs

  11. Thermal fluctuations in resonant motion of fluxons on a Josephson transmission line: Theory and experiment

    DEFF Research Database (Denmark)

    Jørgensen, E.; Koshelets, V. P.; Monaco, Roberto

    1982-01-01

    The radiation emission from long and narrow Josephson tunnel junctions dc-current biased on zero-field steps has been ascribed to resonant motion of fluxons on the transmission line. Within this dynamic model a theoretical expression for the radiation linewidth is derived from a full statistical ...... treatment of thermal fluctuations in the fluxon velocity. The result appears to be very general and is corroborated by experimental determination of linewidth and frequency of radiation emitted from overlap Nb-I-Pb junctions....

  12. Ultrasound imparted air-recoil resonance (UIAR) method for acoustic power estimation: theory and experiment.

    Science.gov (United States)

    Kaiplavil, Sreekumar; Rivens, Ian; ter Haar, Gail

    2013-07-01

    Ultrasound imparted air-recoil resonance (UIAR), a new method for acoustic power estimation, is introduced with emphasis on therapeutic high-intensity focused ultrasound (HIFU) monitoring applications. Advantages of this approach over existing practices include fast response; electrical and magnetic inertness, and hence MRI compatibility; portability; high damage threshold and immunity to vibration and interference; low cost; etc. The angle of incidence should be fixed for accurate measurement. However, the transducer-detector pair can be aligned in any direction with respect to the force of gravity. In this sense, the operation of the device is orientation independent. The acoustic response of a pneumatically coupled pair of Helmholtz resonators, with one of them acting as the sensor head, is used for the estimation of acoustic power. The principle is valid in the case of pulsed/ burst as well as continuous ultrasound exposure, the former being more sensitive and accurate. An electro-acoustic theory has been developed for describing the dynamics of pressure flow and resonance in the system considering various thermo- viscous loss mechanisms. Experimental observations are found to be in agreement with theoretical results. Assuming the window damage threshold (~10 J·mm(-2)) and accuracy of RF power estimation are the upper and lower scale-limiting factors, the performance of the device was examined for an RF power range of 5 mW to 100 W with a HIFU transducer operating at 1.70 MHz, and an average nonlinearity of ~1.5% was observed. The device is also sensitive to sub-milliwatt powers. The frequency response was analyzed at 0.85, 1.70, 2.55, and 3.40 MHz and the results are presented with respective theoretical estimates. Typical response time is in the millisecond regime. Output drift is about 3% for resonant and 5% for nonresonant modes. The principle has been optimized to demonstrate a general-purpose acoustic power meter.

  13. Designing Broadband Access Networks with Triple Redundancy

    DEFF Research Database (Denmark)

    Pedersen, Jens Myrup; Riaz, Muhammad Tahir; Knudsen, Thomas Phillip

    2005-01-01

    An architecture is proposed for designing broadband access networks, which offer triple redundancy to the end users, resulting in networks providing connectivity even in case of any two independent node or line failures. Two physically independent connections are offered by fiber, and the last...... provided by some wireless solution. Based on experience with planning Fiber To The Home, the architecture is designed to meet a number of demands, making it practicable and useful in realworld network planning. The proposed wired topology is planar, and suitable for being fitted onto the road network...

  14. A Search for New Resonances with the Dijet Angular Ratio Using the Compact Muon Solenoid Experiment

    CERN Document Server

    St John, Jason Michael; Harris, Rob

    A search for dijet resonances is performed using 2.2 fb$^{-1}$ of proton-proton collision data at $\\sqrt{s}$ = 7 TeV recorded by the CMS detector at CERN. The study is based on the dijet angular ratio, the ratio of the number of events with the two leading jets having pseudorapidity difference |delta eta| < 1.3 to the number of events with 1.3 < |delta eta| < 3.0. Models of new resonances which decay into two jets typically predict dijet angular distributions and hence, values of the dijet angular ratio which differ from standard model processes. We thus use the measurement of the angular ratio as a function of mass to set limits on the cross sections of new spin -1/2 quark-gluon resonances. We exclude excited quarks of mass less than 3.2 TeV at 95% confidence level, where a limit of 2.8 TeV is expected.

  15. A Search for New Resonances with the Dijet Angular Ratio Using the Compact Muon Solenoid Experiment

    Energy Technology Data Exchange (ETDEWEB)

    John, Jason Michael [Boston Univ., MA (United States)

    2012-01-01

    A search for dijet resonances is performed using 2.2 fb$^{-1}$ of proton-proton collision data at $\\sqrt{s}$ = 7 TeV recorded by the CMS detector at CERN. The study is based on the dijet angular ratio, the ratio of the number of events with the two leading jets having pseudorapidity difference |delta eta| < 1.3 to the number of events with 1.3 < |delta eta| < 3.0. Models of new resonances which decay into two jets typically predict dijet angular distributions and hence, values of the dijet angular ratio which differ from standard model processes. We thus use the measurement of the angular ratio as a function of mass to set limits on the cross sections of new spin -1/2 quark-gluon resonances. We exclude excited quarks of mass less than 3.2 TeV at 95% confidence level, where a limit of 2.8 TeV is expected.

  16. A Ku band pulsed electron paramagnetic resonance spectrometer using an arbitrary waveform generator for quantum control experiments at millikelvin temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Yung Szen, E-mail: yungszen@utm.my [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka-shi, Osaka 560-8531 (Japan); Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor (Malaysia); Tabuchi, Yutaka [Research Center for Advanced Science and Technology (RCAST), The University of Tokyo, Meguro-ku, Tokyo 153-8904 (Japan); Negoro, Makoto; Kagawa, Akinori; Kitagawa, Masahiro, E-mail: kitagawa@ee.es.osaka-u.ac.jp [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka-shi, Osaka 560-8531 (Japan)

    2015-06-15

    We present a 17 GHz (Ku band) arbitrary waveform pulsed electron paramagnetic resonance spectrometer for experiments down to millikelvin temperatures. The spectrometer is located at room temperature, while the resonator is placed either in a room temperature magnet or inside a cryogen-free dilution refrigerator; the operating temperature range of the dilution unit is from ca. 10 mK to 8 K. This combination provides the opportunity to perform quantum control experiments on electron spins in the pure-state regime. At 0.6 T, spin echo experiments were carried out using γ-irradiated quartz glass from 1 K to 12.3 mK. With decreasing temperatures, we observed an increase in spin echo signal intensities due to increasing spin polarizations, in accordance with theoretical predictions. Through experimental data fitting, thermal spin polarization at 100 mK was estimated to be at least 99%, which was almost pure state. Next, to demonstrate the ability to create arbitrary waveform pulses, we generate a shaped pulse by superposing three Gaussian pulses of different frequencies. The resulting pulse was able to selectively and coherently excite three different spin packets simultaneously—a useful ability for analyzing multi-spin system and for controlling a multi-qubit quantum computer. By applying this pulse to the inhomogeneously broadened sample, we obtain three well-resolved excitations at 8 K, 1 K, and 14 mK.

  17. Estimation of parasitic losses in a proposed mesoscale resonant engine: Experiment and model

    Science.gov (United States)

    Preetham, B. S.; Anderson, M.; Richards, C.

    2014-02-01

    A resonant engine in which the piston-cylinder assembly is replaced by a flexible cavity is realized at the mesoscale using flexible metal bellows to demonstrate the feasibility of the concept. A four stroke motoring technique is developed and measurements are performed to determine parasitic losses. A non-linear lumped parameter model is developed to evaluate the engine performance. Experimentally, the heat transfer and friction effects are separated by varying the engine speed and operating frequency. The engine energy flow diagram showing the energy distribution among various parasitic elements reveals that the friction loss in the bellows is smaller than the sliding friction loss in a typical piston-cylinder assembly.

  18. A 250-GHz CARM [Cyclotron Auto Resonance Maser] oscillator experiment driven by an induction linac

    International Nuclear Information System (INIS)

    Caplan, M.; Kulke, B.; Bubp, D.G.; McDermott, D.; Luhmann, N.

    1990-01-01

    A 250-GHz Cyclotron Auto Resonance Maser (CARM) oscillator has been designed and constructed and will be tested using a 1-kA, 2-MeV electron beam produced by the induction linac at the Accelerator Research Center (ARC) facility of Lawrence Livermore National Laboratory (LLNL). The oscillator circuit was made to operate in the TE 11 mode at ten times cutoff using waveguide Bragg reflectors to create an external cavity Q of 8000. Theory predicts cavity fill times of less than 30 ns (pulse length) and efficiencies approaching 20% is sufficiently low transverse electron velocity spreads are maintained (2%)

  19. An interferometric complementarity experiment in a bulk nuclear magnetic resonance ensemble

    International Nuclear Information System (INIS)

    Peng Xinhua; Zhu Xiwen; Fang Ximing; Feng Mang; Liu Maili; Gao Kelin

    2003-01-01

    We have experimentally demonstrated the interferometric complementarity, which relates the distinguishability D quantifying the amount of which-way (WW) information to the fringe visibility V characterizing the wave feature of a quantum entity, in a bulk ensemble by nuclear magnetic resonance (NMR) techniques. We are primarily concerned about the intermediate cases: partial fringe visibility and incomplete WW information. We propose a quantitative measure of D by an alternative geometric strategy and investigate the relation between D and entanglement. By measuring D and V independently, it turns out that the duality relation D 2 + V 2 = 1 holds for pure quantum states of the markers

  20. Search for resonances decaying to top and bottom quarks with the CDF experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aaltonen, Timo Antero [Univ. of Helsinki, Helsinki (Finland). et al.

    2015-08-03

    We report on a search for charged massive resonances decaying to top (t) and bottom (b) quarks in the full data set of proton-antiproton collisions at a center-of-mass energy of √s = 1.96 TeV collected by the CDF II detector at the Tevatron, corresponding to an integrated luminosity of 9.5 fb–1. No significant excess above the standard model background prediction is observed. We set 95% Bayesian credibility mass-dependent upper limits on the heavy charged-particle production cross section times branching ratio to tb. Using a standard model extension with a W' → tb and left-right-symmetric couplings as a benchmark model, we constrain the W' mass and couplings in the 300–900 GeV/c2 range. As a result, the limits presented here are the most stringent for a charged resonance with mass in the range 300–600 GeV/c2 decaying to top and bottom quarks.

  1. Multi-axis force sensing using a resonant composite piezoelectric plate: model and experiments

    Science.gov (United States)

    Castaño-Cano, Davinson; Grossard, Mathieu; Hubert, Arnaud

    2015-05-01

    Wrist force/torque sensors used in robotic applications increase the performances and flexibility of the automated tasks. They also offer new possibilities in the manufacturing process, where physical contact between the work-piece and environment is required. The wide spreading of these sensors is for now restricted by their features. As an alternative to the existing strain-gauges force sensors, this paper presents a resonant composite structure, which is sensitive to multiple components of force that are considered via the pre-stress effect. Structurally bonded piezoelectric patches are used to bring the structure to its resonance, which is shifted according to applied forces. The relationship between force and frequency shift is modelled considering the multi-physics of this smart structure. This model is built using Hamilton's principle and takes into account pre-stress phenomena. A finite element model (FEM) based on Mindlin theory for plates, has been derived from the analytical model. The FEM model is implemented in MATLAB and compared with commercial FE software. Finally, an experimental prototype validates the model, and shows that it is possible to measure multiple force-components with one single sensing element such as a plate.

  2. Magnetic resonance imaging appearance of soft-tissue metastases: our experience at an orthopedic oncology center

    International Nuclear Information System (INIS)

    Sammon, Jennifer; Jain, Abhishek; Bleakney, Robert; Mohankumar, Rakesh

    2017-01-01

    To assess the prevalence and magnetic resonance imaging appearance of metastasis presenting as a soft-tissue mass. A retrospective chart review was performed on 51 patients who presented to an orthopedic oncology center with soft-tissue masses, with a histology-proven diagnosis of soft-tissue metastasis, over a 14-year period. Their magnetic resonance imaging, primary origin, and follow-up have been assessed. Soft-tissue metastasis was identified in patients ranging from 18 to 85 years old. Most (80%) of the masses were located deep to the deep fascia. In our cohort of patients, melanoma was the most common primary malignancy contributing to soft-tissue metastasis (21.8%). Among soft-tissue metastasis from solid organs, breast and lung were the most frequent (9.1% each). Five patients had soft-tissue metastases from an unknown primary. Imaging diagnosis of soft-tissue metastases is challenging as it can demonstrate imaging appearances similar to primary soft-tissue sarcoma. The presence of a known malignancy may not be evident in everyone, and even if available, histopathology will be necessary for diagnosis if this is the only site of recurrence/metastasis to differentiate from a primary soft-tissue sarcoma. Moreover, soft-tissue metastasis may be the initial presentation of a malignancy. Primary malignancies with soft-tissue metastasis carry a poor prognosis; hence, prompt diagnosis and management in essential. (orig.)

  3. Search for Resonances Decaying to Top and Bottom Quarks with the CDF Experiment.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Anzà, F; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bianchi, L; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2015-08-07

    We report on a search for charged massive resonances decaying to top (t) and bottom (b) quarks in the full data set of proton-antiproton collisions at a center-of-mass energy of √[s]=1.96  TeV collected by the CDF II detector at the Tevatron, corresponding to an integrated luminosity of 9.5  fb(-1). No significant excess above the standard model background prediction is observed. We set 95% Bayesian credibility mass-dependent upper limits on the heavy charged-particle production cross section times branching ratio to tb. Using a standard model extension with a W'→tb and left-right-symmetric couplings as a benchmark model, we constrain the W' mass and couplings in the 300-900  GeV/c(2) range. The limits presented here are the most stringent for a charged resonance with mass in the range 300-600  GeV/c(2) decaying to top and bottom quarks.

  4. Initial Clinical Experience in Multiple Myeloma Staging by Means of Whole-Body Resonance Techniques

    International Nuclear Information System (INIS)

    Gallego, J. I.; Concepcion, L.; Alonso, S.; Sanchez, B.; Manzi, F.

    2003-01-01

    To develop a magnetic resonance (MR) exploratory technique equivalent to serial bone X-ray, and to compare their precision in the staging of multiple myeloma (MM) patients. Multiple acquisition T1-weights TSE and STIR sequences in the coronal plane were performed. Ten healthy volunteers and 11 multiple myeloma diagnosed patients were included. The visualization of bony structures was particularly noted,with special attention given to those which would normally be included in a serial bone X-ray. In the case of the patients, a comparison was made between diagnostic capacities of the MR sequences. MR highlighters significantly more (p<0.05) bony elements than did the serial bone X-ray. This was greatly due to a sequential displacement of the scanner bed, allowing for field-of-views which were minimally from head to third proximal of the leg. Magnetic resonance detected a significantly higher number (p<0.05) of lesions. It was, in turn, capable of revealing greater lesion extensions, even to the point of implying staging classification changes in 18% of the patients. The utilization of whole-body MR techniques in multiple myeloma patients is feasible and clinically beneficial. MR is both more sensitive and more specific than serial bone X-ray for evaluation of bony lesions in MM. It is currently serving as a valid alternative in a growing numbers of patients. (Author) 10 refs

  5. Magnetic resonance imaging appearance of soft-tissue metastases: our experience at an orthopedic oncology center

    Energy Technology Data Exchange (ETDEWEB)

    Sammon, Jennifer; Jain, Abhishek; Bleakney, Robert; Mohankumar, Rakesh [Mount Sinai Hospital and University of Toronto, Division of Musculoskeletal Imaging, Joint Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-04-15

    To assess the prevalence and magnetic resonance imaging appearance of metastasis presenting as a soft-tissue mass. A retrospective chart review was performed on 51 patients who presented to an orthopedic oncology center with soft-tissue masses, with a histology-proven diagnosis of soft-tissue metastasis, over a 14-year period. Their magnetic resonance imaging, primary origin, and follow-up have been assessed. Soft-tissue metastasis was identified in patients ranging from 18 to 85 years old. Most (80%) of the masses were located deep to the deep fascia. In our cohort of patients, melanoma was the most common primary malignancy contributing to soft-tissue metastasis (21.8%). Among soft-tissue metastasis from solid organs, breast and lung were the most frequent (9.1% each). Five patients had soft-tissue metastases from an unknown primary. Imaging diagnosis of soft-tissue metastases is challenging as it can demonstrate imaging appearances similar to primary soft-tissue sarcoma. The presence of a known malignancy may not be evident in everyone, and even if available, histopathology will be necessary for diagnosis if this is the only site of recurrence/metastasis to differentiate from a primary soft-tissue sarcoma. Moreover, soft-tissue metastasis may be the initial presentation of a malignancy. Primary malignancies with soft-tissue metastasis carry a poor prognosis; hence, prompt diagnosis and management in essential. (orig.)

  6. Multi-axis force sensing using a resonant composite piezoelectric plate: model and experiments

    International Nuclear Information System (INIS)

    Castaño-Cano, Davinson; Grossard, Mathieu; Hubert, Arnaud

    2015-01-01

    Wrist force/torque sensors used in robotic applications increase the performances and flexibility of the automated tasks. They also offer new possibilities in the manufacturing process, where physical contact between the work-piece and environment is required. The wide spreading of these sensors is for now restricted by their features. As an alternative to the existing strain-gauges force sensors, this paper presents a resonant composite structure, which is sensitive to multiple components of force that are considered via the pre-stress effect. Structurally bonded piezoelectric patches are used to bring the structure to its resonance, which is shifted according to applied forces. The relationship between force and frequency shift is modelled considering the multi-physics of this smart structure. This model is built using Hamilton's principle and takes into account pre-stress phenomena. A finite element model (FEM) based on Mindlin theory for plates, has been derived from the analytical model. The FEM model is implemented in MATLAB and compared with commercial FE software. Finally, an experimental prototype validates the model, and shows that it is possible to measure multiple force-components with one single sensing element such as a plate. (paper)

  7. Analysis of stochastic magnetic fields formed by the application of resonant magnetic perturbations on MAST and comparison with experiment

    International Nuclear Information System (INIS)

    Denner, P.; Liu, Yueqiang; Kirk, A.; Nardon, E.

    2012-01-01

    In MAST experiments with applied resonant magnetic perturbations (RMPs), clear reduction in line-averaged density has been observed in a wide range of L-mode plasmas when there is an alignment between the perturbation and the equilibrium magnetic field that maximizes the size of the resonant components of the applied magnetic field, as well as in a few H-mode plasmas but with a much stronger sensitivity to this alignment. This density pump-out is the result of increased particle transport, which is thought to be caused by the formation of a stochastic magnetic field in the plasma edge. This paper presents an analysis of the magnetic field structures formed by the application of n = 3 RMPs on MAST, including various parameters characterizing the degree of stochasticity in the plasma edge. Values for these parameters are calculated and compared with the amount of density pump-out observed in MAST experiments. It is found that density pump-out is fairly well correlated with some of the parameters calculated using vacuum modelling, but none of them provides a single threshold value for pump-out that applies to both L- and H-mode plasmas. Plasma response modelling provides a robust criterion for density pump-out that applies both to L- and H-mode plasmas. (paper)

  8. Resonant laser power build-up in ALPS-A 'light shining through a wall' experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ehret, Klaus [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Frede, Maik [Laser Zentrum Hannover e.V., Hollerithallee 8, D-30419 Hannover (Germany); Ghazaryan, Samvel [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Hildebrandt, Matthias [Laser Zentrum Hannover e.V., Hollerithallee 8, D-30419 Hannover (Germany); Knabbe, Ernst-Axel [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Kracht, Dietmar [Laser Zentrum Hannover e.V., Hollerithallee 8, D-30419 Hannover (Germany); Lindner, Axel, E-mail: axel.lindner@desy.d [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); List, Jenny [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Meier, Tobias [Max-Planck-Institute for Gravitational Physics, Albert-Einstein-Institute, and Institut fuer Gravitationsphysik, Leibniz Universitaet, Hannover, Callinstrasse 38, D-30167 Hannover (Germany); Meyer, Niels; Notz, Dieter; Redondo, Javier; Ringwald, Andreas [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Wiedemann, Guenter [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany); Willke, Benno [Max-Planck-Institute for Gravitational Physics, Albert-Einstein-Institute, and Institut fuer Gravitationsphysik, Leibniz Universitaet, Hannover, Callinstrasse 38, D-30167 Hannover (Germany)

    2009-12-21

    The ALPS Collaboration runs a 'light shining through a wall' (LSW) experiment to search for photon oscillations into 'weakly interacting sub-eV particles' (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical resonant cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run.

  9. Triple products of Eisenstein series

    Science.gov (United States)

    Venkatesh, Anil

    In this thesis, we construct a Massey triple product on the Deligne cohomology of the modular curve with coefficients in symmetric powers of the standard representation of the modular group. This result is obtained by constructing a Massey triple product on the extension groups in the category of admissible variations of mixed Hodge structure over the modular curve, which induces the desired construction on Deligne cohomology. The result extends Brown's construction of the cup product on Deligne cohomology to a higher cohomological product. Massey triple products on Deligne cohomology have been previously investigated by Deninger, who considered Deligne cohomology with trivial real coefficients. By working over the reals, Deninger was able to compute cohomology exclusively with differential forms. In this work, Deligne cohomology is studied over the rationals, which introduces an obstruction to applying Deninger's results. The obstruction arises from the fact that the integration map from the de Rham complex to the Eilenberg-MacLane complex of the modular group is not an algebra homomorphism. We compute the correction terms of the integration map as regularized iterated integrals of Eisenstein series, and show that these integrals arise in the cup product and Massey triple product on Deligne cohomology.

  10. Solution Patterns Predicting Pythagorean Triples

    Science.gov (United States)

    Ezenweani, Ugwunna Louis

    2013-01-01

    Pythagoras Theorem is an old mathematical treatise that has traversed the school curricula from secondary to tertiary levels. The patterns it produced are quite interesting that many researchers have tried to generate a kind of predictive approach to identifying triples. Two attempts, namely Diophantine equation and Brahmagupta trapezium presented…

  11. Tunable Hybrid Qubit in a Triple Quantum Dot

    Science.gov (United States)

    Wang, Bao-Chuan; Cao, Gang; Li, Hai-Ou; Xiao, Ming; Guo, Guang-Can; Hu, Xuedong; Jiang, Hong-Wen; Guo, Guo-Ping

    2017-12-01

    We experimentally demonstrate quantum-coherent dynamics of a triple-dot-based multielectron hybrid qubit. Pulsed experiments show that this system can be conveniently initialized, controlled, measured electrically, and has a good ratio Q ˜29 between the coherence time and gate time. Furthermore, the current multielectron hybrid qubit has an operation frequency that is tunable in a wide range, from 2 to about 15 GHz. We also provide a qualitative understanding of the experimental observations by mapping them onto a three-electron system. The demonstration of the high tunability in a triple dot system could be potentially useful for future quantum control.

  12. New analysis of ηπ tensor resonances measured at the COMPASS experiment

    Science.gov (United States)

    Jackura, A.; Fernández-Ramírez, C.; Mikhasenko, M.; Pilloni, A.; Mathieu, V.; Nys, J.; Pauk, V.; Szczepaniak, A. P.; Fox, G.; JPAC Collaboration

    2018-04-01

    We present a new amplitude analysis of the ηπ D-wave in the reaction π- p → ηπ- p measured by COMPASS. Employing an analytical model based on the principles of the relativistic S-matrix, we find two resonances that can be identified with the a2 (1320) and the excited a2‧ (1700), and perform a comprehensive analysis of their pole positions. For the mass and width of the a2 we find M = (1307 ± 1 ± 6) MeV and Γ = (112 ± 1 ± 8) MeV, and for the excited state a2‧ we obtain M = (1720 ± 10 ± 60) MeV and Γ = (280 ± 10 ± 70) MeV, respectively.

  13. Scoring sacroiliac joints by magnetic resonance imaging. A Multiple-reader reliability experiment

    DEFF Research Database (Denmark)

    Landewé, RB; Hermann, KG; van der Heijde, DM

    2005-01-01

    Magnetic resonance imaging (MRI) of the sacroiliac (SI) joints and the spine is increasingly important in the assessment of inflammatory activity and structural damage in clinical trials with patients with ankylosing spondylitis (AS). We investigated inter-reader reliability and sensitivity...... for 'depth' and 'intensity,' and the fifth method included the SPARCC slice with the maximum score. Inter-reader reliability was investigated by calculating intraclass correlation coefficients (ICC) for all readers together and for all possible reader pairs. Sensitivity to change was investigated...... values close to zero (no agreement) and highest observed values over 0.80 (excellent agreement). In general, agreement of status scores was somewhat better than agreement of change scores, and agreement of the comprehensive SPARCC scoring system was somewhat better than agreement of the more condensed...

  14. Simulation of fluorescence resonance energy transfer experiments: effect of the dyes on protein folding

    International Nuclear Information System (INIS)

    Allen, Lucy R; Paci, Emanuele

    2010-01-01

    Fluorescence resonance energy transfer is a powerful technique which is often used to probe the properties of proteins and complex macromolecules. The technique relies on relatively large fluorescent dyes which are engineered into the molecule of interest. In the case of small proteins, these dyes may affect the stability of the protein, and modify the folding kinetics and the folding mechanisms which are being probed. Here we use atomistic simulation to investigate the effect that commonly used fluorescent dyes have on the folding of a four-helix bundle protein. We show that, depending on where the dyes are attached, their effect on the kinetic and thermodynamic properties of the protein may be significant. We find that, while the overall folding mechanism is not affected by the dyes, they can destabilize, or even stabilize, intermediate states.

  15. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  16. Scoring inflammatory activity of the spine by magnetic resonance imaging in ankylosing spondylitis: a multireader experiment

    DEFF Research Database (Denmark)

    Lukas, Cédric; Braun, Jürgen; van der Heijde, Désirée

    2007-01-01

    ability was assessed using Z-scores (Mann-Whitney test) comparing change in score between patients treated with TNF-blocking drug and placebo. RESULTS: The mean time to score one set of MRI was shortest for the Berlin method. SDC was lowest for the Berlin method and highest for SPARCC. Overall inter...... of 3 different scoring methods for MRI activity and change in activity of the spine in patients with AS. METHODS: Thirty sets of spinal MRI at baseline and after 24 weeks of followup, derived from a randomized clinical trial comparing a tumor necrosis factor (TNF)-blocking drug (n = 20) with placebo (n...... the Ankylosing Spondylitis spine Magnetic Resonance Imaging-activity [ASspiMRI-a, grading activity (0-6) per vertebral unit in 23 units]; the Berlin modification of the ASspiMRI-a; and the Spondyloarthritis Research Consortium of Canada (SPARCC) scoring system, which scores the 6 vertebral units considered...

  17. The Centroid of a Lie Triple Algebra

    Directory of Open Access Journals (Sweden)

    Xiaohong Liu

    2013-01-01

    Full Text Available General results on the centroids of Lie triple algebras are developed. Centroids of the tensor product of a Lie triple algebra and a unitary commutative associative algebra are studied. Furthermore, the centroid of the tensor product of a simple Lie triple algebra and a polynomial ring is completely determined.

  18. Luminosity optimization schemes in Compton experiments based on Fabry-Perot optical resonators

    Directory of Open Access Journals (Sweden)

    Alessandro Variola

    2011-03-01

    Full Text Available The luminosity of Compton x-ray and γ sources depends on the average current in electron bunches, the energy of the laser pulses, and the geometry of the particle bunch to laser pulse collisions. To obtain high power photon pulses, these can be stacked in a passive optical resonator (Fabry-Perot cavity especially when a high average flux is required. But, in this case, owing to the presence of the optical cavity mirrors, the electron bunches have to collide at an angle with the laser pulses with a consequent luminosity decrease. In this article a crab-crossing scheme is proposed for Compton sources, based on a laser amplified in a Fabry-Perot resonator, to eliminate the luminosity losses given by the crossing angle, taking into account that in laser-electron collisions only the electron bunches can be tilted at the collision point. We report the analytical study on the crab-crossing scheme for Compton gamma sources. The analytical expression for the total yield of photons generated in Compton sources with the crab-crossing scheme of collision is derived. The optimal collision angle of the bunch was found to be equal to half of the collision angle. At this crabbing angle, the maximal yield of scattered off laser photons is attained thanks to the maximization, in the collision process, of the time spent by the laser pulse in the electron bunch. Estimations for some Compton source projects are presented. Furthermore, some schemes of the optical cavities configuration are analyzed and the luminosity calculated. As illustrated, the four-mirror two- or three-dimensional scheme is the most appropriate for Compton sources.

  19. Study of W boson decays and determination of Triple Gauge Couplings in the frame of ALEPH experiment; Etude des desintegrations des bosons W et determination des Auto-Couplages Trilineaires dans le cadre de l'experience ALEPH

    Energy Technology Data Exchange (ETDEWEB)

    Chazelle, Guy [Lab. de Physique Corpusculaire, Clermont-Ferrand-2 Univ., 63 - Aubiere (France)

    1999-07-02

    One of the most important consequence of the fundamental non-Abelian gauge structure of the Electroweak Standard Model is the existence of Triple Gauge-boson Couplings (TGC's). The start of LEP 2 has made it possible for the first time to test the least bound sector of the Standard Model, via the study of the {gamma}W{sup +}W{sup -} and Z{sup 0}W{sup +}W{sup -} vertices. The accuracy is limited by the ambiguities that exist on the different production angles of the quarks and the W{sup -} production angle. These ambiguities can be removed if one is able to distinguish between the up quark and the down quark in the hadronic decays of the W. A charm-jet tagger was therefore developed. It is based on a neural network with 12 variables as input, using mainly charm-lifetime, jet-shape properties, reconstruction of D-mesons and lepton identification. This study has lead to the measurement of one of the least well known CKM matrix element, |V{sub cs}| = 1.034 {+-} 0.051{sub stat} {+-} 0.029{sub syst}. The measurement of the TGC's with the ALEPH detector has led to a dedicated selection of the purely leptonic final states l{nu}-bar l-bar {nu} (l=e,{mu}). The potential sensitivity of this channel to the TGC's depends strongly on the kinematic reconstruction of the undetected neutrinos. A kinematic fitting procedure has thus been developed. The method used to measure the TGC's in this analysis is based on the definition of optimal observables which project out the information contained in the five-fold angular distribution to a set of one-dimensional distributions. The results obtained from the data collected at 183 GeV (1997) and 189 GeV (1998) combined with those obtained from the study of {nu}{nu}-bar {gamma} final states and single W events yield the following 95% confidence level limits: - 0.113 < {delta}g{sub 1}{sup Z} < 0.126; - 0.176 < {delta}{kappa}{sub {gamma}} < 0.467; - 0.163 < {lambda}{sub {gamma}} < 0.094, in agreement with SM expectation

  20. The influence of triple bottom line on international operations management

    Directory of Open Access Journals (Sweden)

    Francisco Sperotto Flores

    2017-12-01

    Full Text Available This paper takes a triple bottom line perspective to analyze how the international operations literature integrates economic, social, and environmental issues. Additionally, it shows the main drivers of and barriers to the adoption of triple bottom line practices by companies in an international context. We conducted a literature review in English language journals which publish research of production and operations management and sustainability, resulting in a final sample of 29 papers. Results show that social and legal pressure for companies to adopt a responsible behavior prompts an isomorphic process that leads them to conduct their operations on behalf of triple bottom line goals. Behavioral differences between spin-offs in various countries caused institutions to create mechanisms that can press and change private standards through regulation and enforcement. There is room for progress in studies that seek to analyze the company’s relationships in its international experience and its multi-institutional relations.

  1. Triple shape memory polymers by 4D printing

    Science.gov (United States)

    Bodaghi, M.; Damanpack, A. R.; Liao, W. H.

    2018-06-01

    This article aims at introducing triple shape memory polymers (SMPs) by four-dimensional (4D) printing technology and shaping adaptive structures for mechanical/bio-medical devices. The main approach is based on arranging hot–cold programming of SMPs with fused decomposition modeling technology to engineer adaptive structures with triple shape memory effect (SME). Experiments are conducted to characterize elasto-plastic and hyper-elastic thermo-mechanical material properties of SMPs in low and high temperatures at large deformation regime. The feasibility of the dual and triple SMPs with self-bending features is demonstrated experimentally. It is advantageous in situations either where it is desired to perform mechanical manipulations on the 4D printed objects for specific purposes or when they experience cold programming inevitably before activation. A phenomenological 3D constitutive model is developed for quantitative understanding of dual/triple SME of SMPs fabricated by 4D printing in the large deformation range. Governing equations of equilibrium are established for adaptive structures on the basis of the nonlinear Green–Lagrange strains. They are then solved by developing a finite element approach along with an elastic-predictor plastic-corrector return map procedure accomplished by the Newton–Raphson method. The computational tool is applied to simulate dual/triple SMP structures enabled by 4D printing and explore hot–cold programming mechanisms behind material tailoring. It is shown that the 4D printed dual/triple SMPs have great potential in mechanical/bio-medical applications such as self-bending gripers/stents and self-shrinking/tightening staples.

  2. Quantitative resonant soft x-ray reflectivity of ultrathin anisotropic organic layers: Simulation and experiment of PTCDA on Au

    International Nuclear Information System (INIS)

    Capelli, R.; Koshmak, K.; Giglia, A.; Mukherjee, S.; Nannarone, S.; Mahne, N.; Doyle, B. P.; Pasquali, L.

    2016-01-01

    Resonant soft X-ray reflectivity at the carbon K edge, with linearly polarized light, was used to derive quantitative information of film morphology, molecular arrangement, and electronic orbital anisotropies of an ultrathin 3,4,9,10-perylene tetracarboxylic dianhydride (PTCDA) film on Au(111). The experimental spectra were simulated by computing the propagation of the electromagnetic field in a trilayer system (vacuum/PTCDA/Au), where the organic film was treated as an anisotropic medium. Optical constants were derived from the calculated (through density functional theory) absorption cross sections of the single molecule along the three principal molecular axes. These were used to construct the dielectric tensor of the film, assuming the molecules to be lying flat with respect to the substrate and with a herringbone arrangement parallel to the substrate plane. Resonant soft X-ray reflectivity proved to be extremely sensitive to film thickness, down to the single molecular layer. The best agreement between simulation and experiment was found for a film of 1.6 nm, with flat laying configuration of the molecules. The high sensitivity to experimental geometries in terms of beam incidence and light polarization was also clarified through simulations. The optical anisotropies of the organic film were experimentally determined and through the comparison with calculations, it was possible to relate them to the orbital symmetry of the empty electronic states.

  3. Quantitative resonant soft x-ray reflectivity of ultrathin anisotropic organic layers: Simulation and experiment of PTCDA on Au

    Energy Technology Data Exchange (ETDEWEB)

    Capelli, R.; Koshmak, K.; Giglia, A.; Mukherjee, S.; Nannarone, S. [IOM-CNR, s.s. 14, Km. 163.5 in AREA Science Park, Basovizza, 34149 Trieste (Italy); Mahne, N. [Elettra, s.s. 14, km 163.5 in AREA Science Park, Basovizza, 34149 Trieste (Italy); Doyle, B. P. [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Pasquali, L., E-mail: luca.pasquali@unimore.it [IOM-CNR, s.s. 14, Km. 163.5 in AREA Science Park, Basovizza, 34149 Trieste (Italy); Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Dipartimento di Ingegneria “Enzo Ferrari,” Università di Modena e Reggio Emilia, Via Vignolese 905, 41125 Modena (Italy)

    2016-07-14

    Resonant soft X-ray reflectivity at the carbon K edge, with linearly polarized light, was used to derive quantitative information of film morphology, molecular arrangement, and electronic orbital anisotropies of an ultrathin 3,4,9,10-perylene tetracarboxylic dianhydride (PTCDA) film on Au(111). The experimental spectra were simulated by computing the propagation of the electromagnetic field in a trilayer system (vacuum/PTCDA/Au), where the organic film was treated as an anisotropic medium. Optical constants were derived from the calculated (through density functional theory) absorption cross sections of the single molecule along the three principal molecular axes. These were used to construct the dielectric tensor of the film, assuming the molecules to be lying flat with respect to the substrate and with a herringbone arrangement parallel to the substrate plane. Resonant soft X-ray reflectivity proved to be extremely sensitive to film thickness, down to the single molecular layer. The best agreement between simulation and experiment was found for a film of 1.6 nm, with flat laying configuration of the molecules. The high sensitivity to experimental geometries in terms of beam incidence and light polarization was also clarified through simulations. The optical anisotropies of the organic film were experimentally determined and through the comparison with calculations, it was possible to relate them to the orbital symmetry of the empty electronic states.

  4. Search for heavy resonance in the top-antitop invariant mass spectrum at the ATLAS experiment in the LHC

    International Nuclear Information System (INIS)

    Dechenaux, B.

    2013-01-01

    This report presents the analysis conducted with the ATLAS experiment at the LHC and searching for resonant production of new particles decaying into a pair of top quarks. Top quark reconstruction is mainly build upon the notion of hadronic jets, whose identification and reconstruction is a crucial issue for any measure trying to sign top quark decays from proton-proton collisions processes. After a general description of the theoretical and experimental features of jet reconstruction in the ATLAS detector, we present a first attempt to validate the local hadronic calibration method, which aim at correcting the measurement of these objects from inaccuracies caused by detector effects. In the second part, we present the analysis conducted on 14 fb -1 of proton-proton collision data at √(s)=8 TeV collected during the year 2012 and searching for resonant creation of new heavy particles in top-anti-top invariant mass spectrum. For heavy particles, the quarks produced in the decay of the latter have a high impulsion with respect to their mass and those top quark decays often results in a so called 'boosted topology', where the hadronic-decaying top quark is often reconstructed as a single jet of large radius parameter. In this context, we present a preliminary study to reconstruct and identify as precisely as possible this type of boosted topologies, based on the study of jet substructure. (author)

  5. Results from the TARC experiment: spallation neutron phenomenology in lead and neutron-driven nuclear transmutation by adiabatic resonance crossing.

    CERN Document Server

    Abánades, A; Andriamonje, Samuel A; Angelopoulos, Angelos; Apostolakis, Alcibiades J; Arnould, H; Belle, E; Bompas, C A; Brozzi, Delecurgo; Bueno, J; Buono, S; Carminati, F; Casagrande, Federico; Cennini, P; Collar, J I; Cerro, E; Del Moral, R; Díez, S; Dumps, Ludwig; Eleftheriadis, C; Embid, M; Fernández, R; Gálvez, J; García, J; Gelès, C; Giorni, A; González, E; González, O; Goulas, I; Heuer, R D; Hussonnois, M; Kadi, Y; Karaiskos, P; Kitis, G; Klapisch, Robert; Kokkas, P; Lacoste, V; Le Naour, C; Lèpez, C; Loiseaux, J M; Martínez-Val, J M; Méplan, O; Nifenecker, H; Oropesa, J; Papadopoulos, I M; Pavlopoulos, P; Pérez-Enciso, E; Pérez-Navarro, A; Perlado, M; Placci, A; Poza, M; Revol, Jean Pierre Charles; Rubbia, Carlo; Rubio, J A; Sakelliou, L; Saldaña, F; Savvidis, E; Schussler, F; Sirvent, C; Tamarit, J; Trubert, D; Tzima, A; Viano, J B; Vieira, S L; Vlachoudis, V; Zioutas, Konstantin; CERN. Geneva. SPS and LEP Division

    2000-01-01

    The results of the TARC experiment are summarized herewith, whose main purpose is to demonstrate the possibility of using Adiabatic Resonance Crossing (ARC) to destroy efficiently Long-Lived Fission Fragments (LLFFs) in accelerator-driven systems and to validate a new simulation developed in the framework of the Energy Amplifier programme. An experimental set-up was installed in a CERN PS proton beam line to study how neutrons, produced by spallation at relatively high energy (En * 1 MeV), slow down quasi adiabatically, with almost flat isolethargic energy distribution and reach the capture resonance energy of an element to be transmuted where they will have a high probability of being captured. Precision measurements of energy and space distributions of spallation neutrons (using 2.5 GeV/c and 3.5 GeV/c protons) slowing down in a 3.3 m x 3.3 m x 3 m lead volume and of neutron capture rates on LLFFs 99Tc, 129I, and several other elements were performed. An appropriate formalism and appropriate computational t...

  6. Development of a new compact intraoperative magnetic resonance imaging system: concept and initial experience.

    Science.gov (United States)

    Morita, Akio; Sameshima, Tetsuro; Sora, Shigeo; Kimura, Toshikazu; Nishimura, Kengo; Itoh, Hirotaka; Shibahashi, Keita; Shono, Naoyuki; Machida, Toru; Hara, Naoko; Mikami, Nozomi; Harihara, Yasushi; Kawate, Ryoichi; Ochiai, Chikayuki; Wang, Weimin; Oguro, Toshiki

    2014-06-01

    Magnetic resonance imaging (MRI) during surgery has been shown to improve surgical outcomes, but the current intraoperative MRI systems are too large to install in standard operating suites. Although 1 compact system is available, its imaging quality is not ideal. We developed a new compact intraoperative MRI system and evaluated its use for safety and efficacy. This new system has a magnetic gantry: a permanent magnet of 0.23 T and an interpolar distance of 32 cm. The gantry system weighs 2.8 tons and the 5-G line is within the circle of 2.6 m. We created a new field-of-view head coil and a canopy-style radiofrequency shield for this system. A clinical trial was initiated, and the system has been used in 44 patients. This system is significantly smaller than previous intraoperative MRI systems. High-quality T2 images could discriminate tumor from normal brain tissue and identify anatomic landmarks for accurate surgery. The average imaging time was 45.5 minutes, and no clinical complications or MRI system failures occurred. Floating organisms or particles were minimal (1/200 L maximum). This intraoperative, compact, low-magnetic-field MRI system can be installed in standard operating suites to provide relatively high-quality images without sacrificing safety. We believe that such a system facilitates the introduction of the intraoperative MRI.

  7. Myocardial late gadolinium enhancement in specific cardiomyopathies by cardiovascular magnetic resonance: a preliminary experience.

    Science.gov (United States)

    Silva, Caterina; Moon, James C; Elkington, Andrew G; John, Anna S; Mohiaddin, Raad H; Pennell, Dudley J

    2007-12-01

    Late gadolinium enhancement cardiovascular magnetic resonance (CMR) can visualize myocardial interstitial abnormalities. The aim of this study was to assess whether regions of abnormal myocardium can also be visualized by late enhancement gadolinium CMR in the specific cardiomyopathies. A retrospective review of all referrals for gadolinium CMR with specific cardiomyopathy over 20 months. Nine patients with different specific cardiomyopathies were identified. Late enhancement was demonstrated in all patients, with a mean signal intensity of 390 +/- 220% compared with normal regions. The distribution pattern of late enhancement was unlike the subendocardial late enhancement related to coronary territories found in myocardial infarction. The affected areas included papillary muscles (sarcoid), the mid-myocardium (Anderson-Fabry disease, glycogen storage disease, myocarditis, Becker muscular dystrophy) and the global sub-endocardium (systemic sclerosis, Loeffler's endocarditis, amyloid, Churg-Strauss). Focal myocardial late gadolinium enhancement is found in the specific cardiomyopathies, and the pattern is distinct from that seen in infarction. Further systematic studies are warranted to assess whether the pattern and extent of late enhancement may aid diagnosis and prognostic assessment.

  8. Production of multi-strange hyperons and strange resonances in the NA49 experiment

    CERN Document Server

    Barton, R A; Anticic, T; Bächler, J; Barna, D; Barnby, L S; Bartke, Jerzy; Betev, L; Bialkowska, H; Billmeier, A; Blume, C; Blyth, C O; Boimska, B; Botje, M; Bracinik, J; Brady, F P; Bramm, R; Brun, R; Buncic, P; Carr, L; Cebra, D; Cooper, G E; Cramer, J G; Csató, P; Eckhardt, F; Ferenc, D; Filip, P; Fischer, H G; Fodor, Z; Foka, P Y; Freund, P; Friese, V; Ftácnik, J; Gál, J; Gazdzicki, M; Georgopoulos, G; Gladysz-Dziadus, E; Hegyi, S; Hlinka, V; Höhne, C; Igo, G; Ivanov, M; Jacobs, P; Janik, R; Jones, P G; Kadija, K; Kolesnikov, V I; Kollegger, T; Kowalski, M; Van Leeuwen, M; Lévai, Peter; Malakhov, A I; Margetis, S; Markert, C; Mayes, B W; Melkumov, G L; Mischke, A; Molnár, J; Nelson, J M; Odyniec, Grazyna Janina; Pálla, G; Panagiotou, A D; Petridis, A; Pikna, M; Pinsky, L; Poskanzer, A M; Prindle, D J; Pühlhofer, F; Reid, J G; Renfordt, R E; Retyk, W; Ritter, H G; Röhrich, D; Roland, C; Roland, G; Rybicki, A; Sammer, T; Sandoval, A; Sann, H; Schäfer, E; Schmitz, N; Seyboth, P; Siklér, F; Sitár, B; Skrzypczak, E; Snellings, R; Squier, G T A; Stock, Reinhard; Strmen, P; Ströbele, H; Susa, T; Szarka, I; Szentpétery, I; Sziklai, J; Toy, M; Trainor, T A; Trentalange, S; Varga, D; Vassiliou, Maria; Veres, G I; Vesztergombi, G; Voloshin, S A; Vranic, D; Wang, F; Weerasundara, D D; Wenig, S; Wetzler, A; Whitten, C; Xu, N; Yates, T A; Yoo, I K; Zimányi, J

    2001-01-01

    The NA49 large-acceptance hadron spectrometer has measured strange and multi-strange hadrons from Pb+Pb and p+p collisions at the CERN SPS. Preliminary results for the transverse mass and rapidity distributions for X and Xi /sup +/ from central Pb+Pb collisions at 158 GeV c/sup -1//nudeon are presented. Fully integrated yields per event of 4.42+or-0.31 and 0.74+0.04 are found for Xi /sup -/ and Xi /sup +/, respectively, leading to a 4 pi Xi /sup +// Xi /sup -/ ratio of 0.17+or-0.02. The ratio Xi /sup +// Xi /sup -/ at mid-rapidity is found to be 0.22+or-0.04, agreeing with previously published values. In addition, preliminary data on the Lambda (1520) and phi (1020) resonances are presented. The Lambda (1520) multiplicity for p+p collisions is found to be 0.012+or-0.003. No signal is observed for Pb+Pb collisions and a production upper limit of 1.36 Lambda (1520) per event indicates an apparent suppression when comparing with scaled p+p data. Integrated phi (1020) yields per event are found to be 7.6+or-1.1 f...

  9. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  10. Utility of Magnetic Resonance Imaging for the Diagnosis of Appendicitis During Pregnancy: A Canadian Experience.

    Science.gov (United States)

    Burns, Michael; Hague, Cameron J; Vos, Patrick; Tiwari, Pari; Wiseman, Sam M

    2017-11-01

    The objective of the study was to evaluate the performance of magnetic resonance imaging (MRI) for the diagnosis of appendicitis during pregnancy. We conducted a retrospective review of all MRI scans performed at our institution, between 2006 and 2012, for the evaluation of suspected appendicitis in pregnant women. Details of the MRI scans performed were obtained from the radiology information system as well as details of any ultrasounds carried out for the same indication. Clinical and pathological data were obtained by retrospective chart review. The study population comprised 63 patients, and 8 patients underwent a second MRI scan during the same pregnancy. A total of 71 MRI scans were reviewed. The appendix was identified on 40 scans (56.3%). Sensitivity of MRI was 75% and specificity was 100% for the diagnosis of appendicitis in pregnant women. When cases with right lower quadrant inflammatory fat stranding or focal fluid, without appendix visualization, were classified as positive for appendicitis, MRI sensitivity increased to 81.3% but specificity decreased to 96.4%. MRI is sensitive and highly specific for the diagnosis of appendicitis during pregnancy and should be considered as a first line imaging study for this clinical presentation. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  11. A study on the hadroproduction of heavy resonances in ATLAS experiment at the LHC

    CERN Document Server

    Domenech-Garret, J L

    2001-01-01

    This work is devoted to the study of the hadroproduction of heavy resonances and related topics. The study begins with a chapter that analyzes some experimental issues on heavy quarkonia production, pointing out the important role that the ATLAS detector at LHC can play in this regard. The main goal of chapter 2 is revising some theoretical aspects on bottomonia production, some relevant heavy quarkonia production models are visited, pointing out the most relevant features involved in this work. Later, chapter 3 describes the most relevant techniques used in order to generate the Upsilon(nS) family, as well as a description on the changes and new implementations in the original software of PYTHIA: In summary, all the tools that we needed when carrying out the bottomonia hadroproduction analysis. In chapter 4 we focused on the study of the information available on Upsilon production, basing our analysis of bottomonia inclusive production on the results from Run IB of the CDF collaboration : We analyze the diff...

  12. Resonant double photoionisation spectroscopy of strontium

    Energy Technology Data Exchange (ETDEWEB)

    Sokell, E; Grimm, M; Sheridan, P, E-mail: emma.sokell@ucd.i, E-mail: paul.sheridan@ucd.i [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland)

    2009-11-01

    Resonant triple-differential cross-section (TDCS) measurements on atomic strontium on the 4p {yields} 4d resonance are presented. All of these TDCS measurements display unexpected lobes at a mutual emission angle for the two electrons of 180{sup o}. Possible explanations for these lobes are explored.

  13. A data acquisition system for measuring ionization cross section in laser multi-step resonant ionization experiment

    International Nuclear Information System (INIS)

    Qian Dongbin; Guo Yuhui; Zhang Dacheng; Chinese Academy of Sciences, Beijing; Ma Xinwen; Zhao Zhizheng; Wang Yanyu; Zu Kailing

    2006-01-01

    A CAMAC data acquisition system for measuring ionization cross section in laser multi-step resonant ionization experiment is described. The number of scalers in the front-end CAMAC can be adjusted by changing the data read-out table files. Both continuous and manual acquisition models are available, and there is a wide adjustable range from 1 ms to 800 s with the acquisition time unit. The long-term stability, Δt/t, for the data acquisition system with an acquisition time unit of 100 s was measured to be better than ±0.01%, thus validating its reliability in long-term online experimental data acquisition. The time response curves for three electrothermal power-meters were also measured by this DAQ system. (authors)

  14. “Next Door” intraoperative magnetic resonance imaging for awake craniotomy: Preliminary experience and technical note

    Science.gov (United States)

    Mathias, Roger Neves; de Aguiar, Paulo Henrique Pires; da Luz Oliveira, Evandro Pinto; Verst, Silvia Mazzali; Vieira, Vinícius; Docema, Marcos Fernando; Calfat Maldaun, Marcos Vinícius

    2016-01-01

    Background: During glioma surgery “maximal safe resection” must be the main goal. Intraoperative magnetic resonance imaging (iMRI) associated with awake craniotomy (AC) is a valuable tool to achieve this objective. In this article, AC with a “next-door” iMRI concept is described in a stepwise protocol. Methods: This is a retrospective analysis of 18 patients submitted to AC using iMRI; a stepwise protocol is also discussed. Results: The mean age was 41.7 years. Hemiparesis, aphasia, and seizures were the main initial symptoms of the patients. Sixty-six percent of the tumors were located in the left hemisphere. All tumors were near or within eloquent areas. Fifty-three percent of the cases were glioblastomas multiforme and 47% of the patients had low grade gliomas. The mean surgical time and iMRI time were 4 h 4 min and 30 min, respectively. New resection was performed in 33% after iMRI. Extent of resection (EOR) higher than 95% was possible in 66.7% of the patients. The main reason of EOR lower than 95% was positive mapping of eloquent areas (6 patients). Eighty percent of the patients experienced improvement of their deficits immediately after the surgery or had a stable clinical status whereas 20% had neurological deterioration, however, all of them improved after 30 days. Conclusion: AC associated with “next-door” iMRI is a complex procedure, but if performed using a meticulous technique, it may improve the overall tumor resection and safety of the patients. PMID:28144477

  15. Magnetic resonance imaging-guided focused ultrasound ablation of uterine fibroids. Early clinical experience

    International Nuclear Information System (INIS)

    Mikami, Koji; Osuga, Keigo; Tomoda, Kaname; Nakamura, Hironobu; Murakami, Takamichi; Okada, Atsuya

    2008-01-01

    The aim of this study was to assess the feasibility and effectiveness of magnetic resonance (MRI)-guided focused ultrasound (MRIgFUS) ablation for uterine fibroids and to identify the candidates for this treatment. A total of 48 patients with a symptomatic uterine fibroid underwent MRIgFUS. The percent ablation volume was calculated, and the patients' characteristics and the MR imaging features of the fibroids that might predict the effect of this treatment were assessed. Changes in the symptoms related to the uterine fibroid were assessed at 6 and 12 months. The planned target zone were successfully treated in 32 patients with bulk-related and menstrual symptoms but unsuccessfully treated in the remaining 16 patients. These 16 patients were obese or their uterine fibroid showed heterogeneous high signal intensity on T2-weighted images. The 32 successfully treated patients were followed up for 6 months. At the 6-month follow-up, bulk-related and menstrual symptoms were diminished in 60% and 51% of patients, respectively. Among them, 17 patients were followed up for 12 months, and 9 of them who showed alleviation of bulk-related symptoms at 6 months had further improvement. The mean percent ablation volume of those nine patients was 51%. In 5 (33%) of the 15 patients with alleviation of menstrual symptoms at 6 months, the symptoms became worse at 12 months. There was a significant difference in the mean percent ablation volume between patients with alleviation of menstrual symptoms and those without (54% vs. 37%; P=0.03). MRIgFUS ablation is a safe, effective treatment for nonobese patients with symptomatic fibroids that show low signal intensity on T2-weighted images. Ablation of more than 50% of the fibroid volume may be needed with a short-term follow-up. (author)

  16. Magnetic resonance imaging of the brain in epileptic adult patients: experience in Ramathibodi Hospital.

    Science.gov (United States)

    Solosrungruang, Anusorn; Laothamatas, Jiraporn; Chinwarun, Yotin

    2007-04-01

    The purpose of the present study was to classify the imaging structural abnormalities of epileptic adult patients referred for magnetic resonance imaging (MR imaging) of the brain at Ramathibodi Hospital and to correlate with the clinical data and EEG. MR imaging of 91 adult epileptic patients (age ranging from 15-85 years old with an average of 36.90 years old) were retrospectively reviewed and classified into eight groups according to etiologies. Then clinical data and EEG correlations were analyzed using the Kappa analysis. All of the MR imaging of the brain were performed at Ramathibodi Hospital from January 2001 to December 2002. Secondary generalized tonic clonic seizure was the most common clinical presenting seizure type. Extra temporal lobe epilepsy was the most common clinical diagnosis. Of the thirty-three patients who underwent EEG before performing MR imaging, 17 had normal EEG From MR imaging, temporal lobe lesion was the main affected location and mesial temporal sclerosis (MTS) was the most common cause of the epilepsy in patients. For age group classification, young adult (15-34 years old) and adult (35-64 years old) age groups, MTS was the most common etiology of epilepsy with cortical dysplasia being the second most common cause for the first group and vascular disease for the latter group. For the older age group (> 64 years old), vascular disease and idiopathic cause were equally common etiologies. MRI, EEG findings, and clinical data were all concordant with statistical significance. MRI is the non-invasive modality of choice for evaluation of the epileptic patients. The result is concordant with the clinical and EEG findings. It can detect and localize the structural abnormality accurately and is useful in the treatment planning.

  17. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    International Nuclear Information System (INIS)

    Friedman, P.; Enis, S.; Pinyard, J.

    2009-01-01

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  18. Magnetic resonance imaging - guided vacuum-assisted breast biopsy: an initial experience in a community hospital

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, P.; Enis, S.; Pinyard, J., E-mail: jpinyard@gmail.com [Morristown Memorial Hospital, The Carol W. and Julius A. Rippel Breast Center, The Carol G. Simon Cancer Centre, Morristown, New Jersey (United States)

    2009-10-15

    To evaluate the effectiveness in diagnosing mammographically and sonographically occult breast lesions by using magnetic resonance imaging (MRI) guided vacuum-assisted breast biopsy in patients who presented to a community-based hospital with a newly established breast MRI program. The records of 142 consecutive patients, median age of 55 years, who had undergone MRI-guided biopsy at our institution between July 2006 and July 2007 were reviewed. From these patients, 197 mammographically and sonographically occult lesions were biopsied at the time of discovery. The pathology was then reviewed and correlated with the MRI findings. Cancer was present and subsequently discovered in 8% of the previously occult lesions (16/197) or 11% of the women studied (16/142). Of the cancerous lesions, 56% were invasive carcinomas (9/16) and 44% were ductal carcinomas in situ (7/16). Fourteen percent of the discovered lesions (28/197) were defined as high risk and included atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, and radial scar. In total, occult cancerous and high-risk lesions were discovered in 22% of the found lesions (44/197) or 31% of the women who underwent MRI-guided biopsy (44/142). This study demonstrated that detection of cancerous and high-risk lesions can be significantly increased when an MRI-guided biopsy program is introduced at a community-based hospital. We believe that as radiologists gain confidence in imaging and histologic correlation, community-based hospitals can achieve similar rates of occult lesion diagnosis as those found in data emerging from academic institutions. (author)

  19. Modal planes are spectral triples

    International Nuclear Information System (INIS)

    Gayral, Victor; Iochum, Bruno; Schuecker, Thomas; Gracia-Bondia, Jose M.; Varilly, Joseph C.

    2003-09-01

    Axioms for nonunital spectral triples, extending those introduced in the unital case by Connes, are proposed. As a guide, and for the sake of their importance in noncommutative quantum field theory, the spaces R 2N endowed with Moyal products are intensively investigated. Some physical applications, such as the construction of noncommutative Wick monomials and the computation of the Connes-Lott functional action, are given for these noncommutative hyperplanes. (author)

  20. Detuned resonances of Tollmien-Schlichting waves in an airfoil boundary layer: Experiment, theory, and direct numerical simulation

    Science.gov (United States)

    Würz, W.; Sartorius, D.; Kloker, M.; Borodulin, V. I.; Kachanov, Y. S.; Smorodsky, B. V.

    2012-09-01

    Transition prediction in two-dimensional laminar boundary layers developing on airfoil sections at subsonic speeds and very low turbulence levels is still a challenge. The commonly used semi-empirical prediction tools are mainly based on linear stability theory and do not account for nonlinear effects present unavoidably starting with certain stages of transition. One reason is the lack of systematic investigations of the weakly nonlinear stages of transition, especially of the strongest interactions of the instability modes predominant in non-self-similar boundary layers. The present paper is devoted to the detailed experimental, numerical, and theoretical study of weakly nonlinear subharmonic resonances of Tollmien-Schlichting waves in an airfoil boundary layer, representing main candidates for the strongest mechanism of these initial nonlinear stages. The experimental approach is based on phase-locked hot-wire measurements under controlled disturbance conditions using a new disturbance source being capable to produce well-defined, complex wave compositions in a wide range of streamwise and spanwise wave numbers. The tests were performed in a low-turbulence wind tunnel at a chord Reynolds number of Re = 0.7 × 106. Direct numerical simulations (DNS) were utilized to provide a detailed comparison for the test cases. The results of weakly nonlinear theory (WNT) enabled a profound understanding of the underlying physical mechanisms observed in the experiments and DNS. The data obtained in experiment, DNS and WNT agree basically and provide a high degree of reliability of the results. Interactions occurring between components of various initial frequency-wavenumber spectra of instability waves are investigated by systematic variation of parameters. It is shown that frequency-detuned and spanwise-wavenumber-detuned subharmonic-type resonant interactions have an extremely large spectral width. Similar to results obtained for self-similar base flows it is found that the

  1. Resonant laser power build-up in ALPS. A 'light-shining-through-walls' experiment

    International Nuclear Information System (INIS)

    Ehret, Klaus; Ghazaryan, Samvel; Frede, Maik

    2009-05-01

    The ALPS collaboration runs a light-shining-through-walls (LSW) experiment to search for photon oscillations into weakly interacting sub-eV particles (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run. (orig.)

  2. Magnetic resonance tomography of the orbit: First experiences with the paramagnetic contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Markl, A.; Vogl, T.; Scheidhauer, K.; Riedel, K.G.; Oeckler, R.

    1986-01-01

    In 21 patients with orbital mass lesions MRI was performed before and after administration of paramagnetic contrast medium, gadolinium-DPTA. In comparison to the plain scan the differentiation of the tumorous tissue against the surrounding structures was improved after application of contrast medium despite a partially moderate increase in signal intensity. Especially highly vascular tumors and vessel diseases show a significant contrast enhancement. With increasing experience in larger number of patients a tissue differentiation seems to be possible. (orig.) [de

  3. Pulmonary embolism and pelvic-lower limb deep venous thrombosis: initial experience with magnetic resonance angiography

    International Nuclear Information System (INIS)

    Jiang Tao; Qiu Chuanya; Jiang Hua

    2004-01-01

    Objective: To evaluate the usefulness of combined three-dimensional (3D) and two-dimensional (2D) contrast enhanced magnetic resonance angiography (CE-MRA) for checking the thrombus embolism of different positions within single examination on the pulmonary artery and pelvic-lower limb deep veins. Methods: Fifteen patients with suspected pulmonary embolism and pelvic-lower limb deep venous thrombosis (DVT) were evaluate with combined 3D MRA and 2D CE-MRA. 3D spoiled gradient-recalled-echo bolus chase MR angiograms were obtained in four stations from the pulmonary artery to the ankle. Thereafter, 3D CE MRA was reversely scanned from the ankle to the pelvic. 2D contrast-enhanced MRI was obtained in pelvis, thigh, and calf. Pulmonary CT angiography (CTA) and/or DSA were performed in 15 patients, and duplex ultrasonography of lower-limb vein was performed in 12 patients. Results: Of the 15 cases, acceptable imaging of pulmonary vessel was acquired with 3D CE-MRA in 12 cases. The signal intensity was lower in the deep iliac vein and lower extremities than that in the artery, but vein frame was distinct after post processing. The artery and deep vein were clearly revealed with contrast enhanced FSPGR sequence in 15 cases. 3D CD-MRA imaging disclosed pulmonary embolism in fourteen patients and pelvis-lower limb DVT with multi-place involvement in nine patients. 2D contrast-enhanced MR imaging proved DVT in pelvis-lower limb. 2D contrast-enhanced FSPGR sequence was a complementation of 3D CE-MRA and it had larger scan field. Thrombus presented as low signals and eccentral or intraluminal filling defect. Local caliber of vein thrombus in 6 cases was evidently broadened. Conclusion: Within only one MR examination procedure, it is capable of examining the pulmonary embolism and DVT of pelvis-lower limb with combined 3D MRA and 2D contrast enhanced MR. The results are promising as a non-invasion 'on-stop shopping' tool in the evaluation of thromboembolic disease

  4. Real-time magnetic resonance imaging of deep venous flow during muscular exercise-preliminary experience.

    Science.gov (United States)

    Joseph, Arun Antony; Merboldt, Klaus-Dietmar; Voit, Dirk; Dahm, Johannes; Frahm, Jens

    2016-12-01

    The accurate assessment of peripheral venous flow is important for the early diagnosis and treatment of disorders such as deep-vein thrombosis (DVT) which is a major cause of post-thrombotic syndrome or even death due to pulmonary embolism. The aim of this work is to quantitatively determine blood flow in deep veins during rest and muscular exercise using a novel real-time magnetic resonance imaging (MRI) method for velocity-encoded phase-contrast (PC) MRI at high spatiotemporal resolution. Real-time PC MRI of eight healthy volunteers and one patient was performed at 3 Tesla (Prisma fit, Siemens, Erlangen, Germany) using a flexible 16-channel receive coil (Variety, NORAS, Hoechberg, Germany). Acquisitions were based on a highly undersampled radial FLASH sequence with image reconstruction by regularized nonlinear inversion at 0.5×0.5×6 mm 3 spatial resolution and 100 ms temporal resolution. Flow was assessed in two cross-sections of the lower leg at the level of the calf muscle and knee using a protocol of 10 s rest, 20 s flexion and extension of the foot, and 10 s rest. Quantitative analyses included through-plane flow in the right posterior tibial, right peroneal and popliteal vein (PC maps) as well as signal intensity changes due to flow and muscle movements (corresponding magnitude images). Real-time PC MRI successfully monitored the dynamics of venous flow at high spatiotemporal resolution and clearly demonstrated increased flow in deep veins in response to flexion and extension of the foot. In normal subjects, the maximum velocity (averaged across vessel lumen) during exercise was 9.4±5.7 cm·s -1 for the right peroneal vein, 8.5±4.6 cm·s -1 for the right posterior tibial vein and 17.8±5.8 cm·s -1 for the popliteal vein. The integrated flow volume per exercise (20 s) was 1.9, 1.6 and 50 mL (mean across subjects) for right peroneal, right posterior tibial and popliteal vein, respectively. A patient with DVT presented with peak flow velocities of only

  5. 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, N.; Gieseke, J.; Kuhl, C.; Lutterbey, G.; Falkenhausen, M. von; Traeber, F.; Zivanovic, O.; Schild, H.H.

    2005-01-01

    The purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7 x 1.04 x 4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; 1 is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: 1 is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner

  6. Triple-resonance multidimensional NMR study of calmodulin complexed with the binding domain of skeletal muscle myosin light-chain kinase: Indication of a conformational change in the central helix

    International Nuclear Information System (INIS)

    Ikura, Mitsuhiko; Kay, L.E.; Bax, A.; Krinks, M.

    1991-01-01

    Heteronuclear 3D and 4D NMR experiments have been used to obtain 1 H, 13 C, and 15 N backbone chemical shift assignments in Ca 2+ -loaded clamodulin complexed with a 26-residue synthetic peptide (M13) corresponding to the calmodulin-bionding domain (residues 577-602) of rabbit skeletal muscle muosin light-chain kinase. Comparison of the chemical shift values with those observed in peptide-free calmodulin shows that binding of M13 peptide induces substantial chemical shift changes that are not localized in one particular region of the protein. The largest changes are found in the first helix of the Ca 2+ -binding site 1 (E11-E14), the N-terminal portion of the central helix (M72-D78), and the second helix of the Ca 2+ -binding site 4 (F141-M145). Analysis of backbone NOE connectivities indicates a change from α-helical to an extended conformation for residues 75-77 upon complexation with M13. Upon complexation with M13, a significant decrease in the amide exchange rate is observed for residues T110, L112, G113, and E114 at the end of the second helix of site 3

  7. Patients' experience of outsourcing and care related to magnetic resonance examinations.

    Science.gov (United States)

    Tavakol Olofsson, Parvin; Aspelin, Peter; Bergstrand, Lott; Blomqvist, Lennart

    2014-11-01

    Outsourcing radiological examinations from public university hospitals affects the patient, who has to attend a different clinic or hospital for the radiological examination. We currently have a limited understanding of how patients view outsourcing and their care related to MR examinations. To examine the experiences of patients who are sent to private radiology units when their referrals for MR examinations are outsourced from a university hospital, as well as to explore factors which influence patient satisfaction regarding the quality of care related to the MR examination. A group of patients (n = 160) referred for MR examinations and either examined at a university hospital or at an external private unit were interviewed. The interview was designed as a verbal questionnaire. Data were analyzed using Student's t test, analysis of variance (ANOVA), and Pearson's correlation. Sixty-nine percent of the patients could neither choose nor influence the location at which they were examined. For those who could, aspects that influenced the patient's choice of radiology department were: short waiting time 79% (127/160), ease of traveling to the radiology department 68% (110/160), and short distance to their home or work 58% (93/160). For 40% (60/160) of the patients, a short time in the waiting room was related to a positive experience of the MR examination. If patients were informed about outsourcing and could also choose where to have their examination, key factors contributing to patient satisfaction could be met even when MR examinations are outsourced.

  8. Dynamic oxygen-enhanced magnetic resonance imaging of the lung in asthma—Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Juan, E-mail: weijuan.zhang@postgrad.manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Niven, Robert M., E-mail: robert.niven@uhsm.nhs.uk [North West Lung Research Centre, University Hospital of South Manchester, Southmoor Road, Manchester M23 9LT (United Kingdom); Young, Simon S., E-mail: Simon.Young1@astrazeneca.com [Personalised Healthcare and Biomarkers, AstraZeneca R and D, Alderley Park, Macclesfield SK10 4TF (United Kingdom); Liu, Yu-Zhen, E-mail: yu-zhen.liu@astrazeneca.com [Personalised Healthcare and Biomarkers, AstraZeneca R and D, Alderley Park, Macclesfield SK10 4TF (United Kingdom); Parker, Geoffrey J.M., E-mail: Geoff.parker@manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Bioxydyn Limited, Rutherford House, Pencroft Way, Manchester M15 6SZ (United Kingdom); Naish, Josephine H., E-mail: Josephine.naish@manchester.ac.uk [Centre for Imaging Sciences, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Biomedical Imaging Institute, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom)

    2015-02-15

    Highlights: • Oxygen-enhanced MRI may have a role in the estimation of disease severity in asthma. • Heterogeneity of parameter maps reflects localized functional impairment in asthma. • OE-MRI provides non-ionising, spatial and temporal information on oxygen delivery. - Abstract: Objectives: To prospectively estimate the feasibility and reproducibility of dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) in the assessment of regional oxygen delivery, uptake and washout in asthmatic lungs. Materials and methods: The study was approved by the National Research Ethics Committee and written informed consent was obtained. Dynamic OE-MRI was performed twice at one month apart on four mild asthmatic patients (23 ± 5 years old, FEV{sub 1} = 96 ± 3% of predicted value) and six severe asthmatic patients (41 ± 12 years old, FEV{sub 1} = 60 ± 14% of predicted value) on a 1.5 T MR scanner using a two-dimensional T{sub 1}-weighted inversion-recovery turbo spin echo sequence. The enhancing fraction (EF), the maximal change in the partial pressure of oxygen in lung tissue (ΔPO{sub 2max{sub l}}) and arterial blood of the aorta (ΔPO{sub 2max{sub a}}), and the oxygen wash-in (τ{sub up{sub l}}, τ{sub up{sub a}}) and wash-out (τ{sub down{sub l}}, τ{sub down{sub a}}) time constants were extracted and compared between groups using the independent-samples t-test (two-tailed). Correlations between imaging readouts and clinical measurements were assessed by Pearson's correlation analysis. Bland–Altman analysis was used to estimate the levels of agreement between the repeat scans and the intra-observer agreement in the MR imaging readouts. Results: The severe asthmatic group had significantly smaller EF (70 ± 16%) and median ΔPO{sub 2max{sub l}} (156 ± 52 mmHg) and significantly larger interquartile range of τ{sub up{sub l}} (0.84 ± 0.26 min) than the mild asthmatic group (95 ± 3%, P = 0.014; 281 ± 40 mmHg, P = 0.004; 0.20 ± 0.07 min, P = 0

  9. Dynamic oxygen-enhanced magnetic resonance imaging of the lung in asthma—Initial experience

    International Nuclear Information System (INIS)

    Zhang, Wei-Juan; Niven, Robert M.; Young, Simon S.; Liu, Yu-Zhen; Parker, Geoffrey J.M.; Naish, Josephine H.

    2015-01-01

    Highlights: • Oxygen-enhanced MRI may have a role in the estimation of disease severity in asthma. • Heterogeneity of parameter maps reflects localized functional impairment in asthma. • OE-MRI provides non-ionising, spatial and temporal information on oxygen delivery. - Abstract: Objectives: To prospectively estimate the feasibility and reproducibility of dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) in the assessment of regional oxygen delivery, uptake and washout in asthmatic lungs. Materials and methods: The study was approved by the National Research Ethics Committee and written informed consent was obtained. Dynamic OE-MRI was performed twice at one month apart on four mild asthmatic patients (23 ± 5 years old, FEV 1 = 96 ± 3% of predicted value) and six severe asthmatic patients (41 ± 12 years old, FEV 1 = 60 ± 14% of predicted value) on a 1.5 T MR scanner using a two-dimensional T 1 -weighted inversion-recovery turbo spin echo sequence. The enhancing fraction (EF), the maximal change in the partial pressure of oxygen in lung tissue (ΔPO 2max l ) and arterial blood of the aorta (ΔPO 2max a ), and the oxygen wash-in (τ up l , τ up a ) and wash-out (τ down l , τ down a ) time constants were extracted and compared between groups using the independent-samples t-test (two-tailed). Correlations between imaging readouts and clinical measurements were assessed by Pearson's correlation analysis. Bland–Altman analysis was used to estimate the levels of agreement between the repeat scans and the intra-observer agreement in the MR imaging readouts. Results: The severe asthmatic group had significantly smaller EF (70 ± 16%) and median ΔPO 2max l (156 ± 52 mmHg) and significantly larger interquartile range of τ up l (0.84 ± 0.26 min) than the mild asthmatic group (95 ± 3%, P = 0.014; 281 ± 40 mmHg, P = 0.004; 0.20 ± 0.07 min, P = 0.001, respectively). EF, median ΔPO 2max l and τ down l and the interquartile range of τ up l

  10. Energy Efficient Triple IG Automation EEE (Triple-E)

    Energy Technology Data Exchange (ETDEWEB)

    McGlinchy, Timothy B

    2013-02-28

    GED Integrated Solutions collaborated with US window and door manufactures to investigate, design and verify technical and cost feasibility for producing high performance, high volume, low material and labor cost window, utilizing a modified window design containing a triple insulating glass unit (IGU). This window design approach when combined with a high volume IGU manufacturing system, can produce R5 rated windows for an approximate additional consumer cost of only $4 per square foot when compared to conventional Low-E argon dual pane IG windows, resulting in a verify practical, reliable and affordable high performance window for public use.

  11. RITA-type triple axis spectrometers

    International Nuclear Information System (INIS)

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  12. Reactive carbon-chain molecules: synthesis of 1-diazo-2,4-pentadiyne and spectroscopic characterization of triplet pentadiynylidene (H-C[triple bond]C-:C-C[triple bond]C-H).

    Science.gov (United States)

    Bowling, Nathan P; Halter, Robert J; Hodges, Jonathan A; Seburg, Randal A; Thomas, Phillip S; Simmons, Christopher S; Stanton, John F; McMahon, Robert J

    2006-03-15

    1-Diazo-2,4-pentadiyne (6a), along with both monodeuterio isotopomers 6b and 6c, has been synthesized via a route that proceeds through diacetylene, 2,4-pentadiynal, and 2,4-pentadiynal tosylhydrazone. Photolysis of diazo compounds 6a-c (lambda > 444 nm; Ar or N2, 10 K) generates triplet carbenes HC5H (1) and HC5D (1-d), which have been characterized by IR, EPR, and UV/vis spectroscopy. Although many resonance structures contribute to the resonance hybrid for this highly unsaturated carbon-chain molecule, experiment and theory reveal that the structure is best depicted in terms of the dominant resonance contributor of penta-1,4-diyn-3-ylidene (diethynylcarbene, H-C[triple bond]C-:C-C[triple bond]C-H). Theory predicts an axially symmetric (D(infinity h)) structure and a triplet electronic ground state for 1 (CCSD(T)/ANO). Experimental IR frequencies and isotope shifts are in good agreement with computed values. The triplet EPR spectrum of 1 (absolute value(D/hc) = 0.6157 cm(-1), absolute value(E/hc) = 0.0006 cm(-1)) is consistent with an axially symmetric structure, and the Curie law behavior confirms that the triplet state is the ground state. The electronic absorption spectrum of 1 exhibits a weak transition near 400 nm with extensive vibronic coupling. Chemical trapping of triplet HC5H (1) in an O2-doped matrix affords the carbonyl oxide 16 derived exclusively from attack at the central carbon.

  13. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  14. Patients’ experience of outsourcing and care related to magnetic resonance examinations

    Science.gov (United States)

    Aspelin, Peter; Bergstrand, Lott; Blomqvist, Lennart

    2014-01-01

    Background Outsourcing radiological examinations from public university hospitals affects the patient, who has to attend a different clinic or hospital for the radiological examination. We currently have a limited understanding of how patients view outsourcing and their care related to MR examinations. Aim Aim. To examine the experiences of patients who are sent to private radiology units when their referrals for MR examinations are outsourced from a university hospital, as well as to explore factors which influence patient satisfaction regarding the quality of care related to the MR examination. Methods A group of patients (n = 160) referred for MR examinations and either examined at a university hospital or at an external private unit were interviewed. The interview was designed as a verbal questionnaire. Data were analyzed using Student’s t test, analysis of variance (ANOVA), and Pearson’s correlation. Results Sixty-nine percent of the patients could neither choose nor influence the location at which they were examined. For those who could, aspects that influenced the patient’s choice of radiology department were: short waiting time 79% (127/160), ease of traveling to the radiology department 68% (110/160), and short distance to their home or work 58% (93/160). For 40% (60/160) of the patients, a short time in the waiting room was related to a positive experience of the MR examination. Conclusion Conclusion. If patients were informed about outsourcing and could also choose where to have their examination, key factors contributing to patient satisfaction could be met even when MR examinations are outsourced. PMID:25142133

  15. Initial experience of functional imaging of upper urinary tract neoplasm by diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yoshida, Soichiro; Masuda, Hitoshi; Saito, Kazutaka; Kawakami, Satoru; Kihara, Kazunori; Ishii, Chikako

    2008-01-01

    Diffusion-weighted (DW) magnetic resonance imaging (MRI) provides functional information widely used in the diagnosis of acute cerebral stroke. We reported our initial experience of this imaging technique of upper urinary tract (UUT) urothelial carcinoma (UC). Diffusion-weighted magnetic resonance imaging was carried out in 10 consecutive patients with suspected UUT UC. With conventional imaging, seven were diagnosed as having renal pelvic tumors and two were highly suspected of having UUT UC. These nine patients were diagnosed histopathologically as having renal pelvic UC by subsequent operation. The last patient was confirmed as experiencing benign stenosis. DW MRI was obtained with a 1.5-T MR imager without a breath-holding sequence. The apparent diffusion coefficient (ADC) values of renal parenchyma, dilated collecting system, and tumor were calculated. The differences were analyzed using Wilcoxon t-test. On DW MRI, all nine tumors showed hyperintensity with negligible urinary intensity. Two cases of highly suspected UUT UC with unclear conventional MRI had high signal intensity and contrast. The case of benign stenosis had negative DW MRI. The median (range) ADC value of the tumor (0.803 [0.412-0.958] x 10 -3 mm 2 /s) was significantly lower than those of the dilated collecting system (2.19 [1.42-2.40] x 10 -3 ) and renal parenchyma (1.28 [0.922-1.45] x 10 -3 , respectively (P<0.01 and P<0.01). This is the first report on the application of DW MRI for a series of UUT UC. With this technique, a clear demonstration of UUT UC could be obtained. Moreover, this imaging technique is potentially useful to identify small lesions if they have a low diffusion coefficient. (author)

  16. Results from the TARC experiment: spallation neutron phenomenology in lead and neutron-driven nuclear transmutation by adiabatic resonance crossing

    Science.gov (United States)

    Abánades, A.; Aleixandre, J.; Andriamonje, S.; Angelopoulos, A.; Apostolakis, A.; Arnould, H.; Belle, E.; Bompas, C. A.; Brozzi, D.; Bueno, J.; Buono, S.; Carminati, F.; Casagrande, F.; Cennini, P.; Collar, J. I.; Cerro, E.; Del Moral, R.; Díez, S.; Dumps, L.; Eleftheriadis, C.; Embid, M.; Fernández, R.; Gálvez, J.; García, J.; Gelès, C.; Giorni, A.; González, E.; González, O.; Goulas, I.; Heuer, D.; Hussonnois, M.; Kadi, Y.; Karaiskos, P.; Kitis, G.; Klapisch, R.; Kokkas, P.; Lacoste, V.; Le Naour, C.; López, C.; Loiseaux, J. M.; Martínez-Val, J. M.; Méplan, O.; Nifenecker, H.; Oropesa, J.; Papadopoulos, I.; Pavlopoulos, P.; Pérez-Enciso, E.; Pérez-Navarro, A.; Perlado, M.; Placci, A.; Poza, M.; Revol, J.-P.; Rubbia, C.; Rubio, J. A.; Sakelliou, L.; Saldaña, F.; Savvidis, E.; Schussler, F.; Sirvent, C.; Tamarit, J.; Trubert, D.; Tzima, A.; Viano, J. B.; Vieira, S.; Vlachoudis, V.; Zioutas, K.

    2002-02-01

    We summarize here the results of the TARC experiment whose main purpose is to demonstrate the possibility of using Adiabatic Resonance Crossing (ARC) to destroy efficiently Long-Lived Fission Fragments (LLFFs) in accelerator-driven systems and to validate a new simulation developed in the framework of the Energy Amplifier programme. An experimental set-up was installed in a CERN PS proton beam line to study how neutrons produced by spallation at relatively high energy ( E n⩾1 MeV) slow down quasi-adiabatically with almost flat isolethargic energy distribution and reach the capture resonance energy of an element to be transmuted where they will have a high probability of being captured. Precision measurements of energy and space distributions of spallation neutrons (using 2.5 and 3.5 GeV/ c protons) slowing down in a 3.3 m×3.3 m×3 m lead volume and of neutron capture rates on LLFFs 99Tc, 129I, and several other elements were performed. An appropriate formalism and appropriate computational tools necessary for the analysis and understanding of the data were developed and validated in detail. Our direct experimental observation of ARC demonstrates the possibility to destroy, in a parasitic mode, outside the Energy Amplifier core, large amounts of 99Tc or 129I at a rate exceeding the production rate, thereby making it practical to reduce correspondingly the existing stockpile of LLFFs. In addition, TARC opens up new possibilities for radioactive isotope production as an alternative to nuclear reactors, in particular for medical applications, as well as new possibilities for neutron research and industrial applications.

  17. Set up of a method for the adjustment of resonance parameters on integral experiments; Mise au point d`une methode d`ajustement des parametres de resonance sur des experiences integrales

    Energy Technology Data Exchange (ETDEWEB)

    Blaise, P.

    1996-12-18

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.).

  18. Pursuing the Triple Aim: The First 7 Years.

    Science.gov (United States)

    Whittington, John W; Nolan, Kevin; Lewis, Ninon; Torres, Trissa

    2015-06-01

    POLICY POINTS: In 2008, researchers at the Institute for Healthcare Improvement (IHI) proposed the Triple Aim, strategic organizing principles for health care organizations and geographic communities that seek, simultaneously, to improve the individual experience of care and the health of populations and to reduce the per capita costs of care for populations. In 2010, the Triple Aim became part of the US national strategy for tackling health care issues, especially in the implementation of the Patient Protection and Affordable Care Act (ACA) of 2010. Since that time, IHI and others have worked together to determine how the implementation of the Triple Aim has progressed. Drawing on our 7 years of experience, we describe 3 major principles that guided the organizations and communities working on this endeavor: creating the right foundation for population management, managing services at scale for the population, and establishing a learning system to drive and sustain the work over time. In 2008, researchers at the Institute for Healthcare Improvement (IHI) described the Triple Aim as simultaneously "improving the individual experience of care; improving the health of populations; and reducing the per capita costs of care for populations." IHI and its close colleagues had determined that both individual and societal changes were needed. In 2007, IHI began recruiting organizations from around the world to participate in a collaborative to implement what became known as the Triple Aim. The 141 participating organizations included health care systems, hospitals, health care insurance companies, and others closely tied to health care. In addition, key groups outside the health care system were represented, such as public health agencies, social services groups, and community coalitions. This collaborative provided a structure for observational research. By noting the contrasts between the contexts and structures of those sites in the collaborative that progressed and

  19. Resting-state functional magnetic resonance imaging for surgical planning in pediatric patients: a preliminary experience.

    Science.gov (United States)

    Roland, Jarod L; Griffin, Natalie; Hacker, Carl D; Vellimana, Ananth K; Akbari, S Hassan; Shimony, Joshua S; Smyth, Matthew D; Leuthardt, Eric C; Limbrick, David D

    2017-12-01

    OBJECTIVE Cerebral mapping for surgical planning and operative guidance is a challenging task in neurosurgery. Pediatric patients are often poor candidates for many modern mapping techniques because of inability to cooperate due to their immature age, cognitive deficits, or other factors. Resting-state functional MRI (rs-fMRI) is uniquely suited to benefit pediatric patients because it is inherently noninvasive and does not require task performance or significant cooperation. Recent advances in the field have made mapping cerebral networks possible on an individual basis for use in clinical decision making. The authors present their initial experience translating rs-fMRI into clinical practice for surgical planning in pediatric patients. METHODS The authors retrospectively reviewed cases in which the rs-fMRI analysis technique was used prior to craniotomy in pediatric patients undergoing surgery in their institution. Resting-state analysis was performed using a previously trained machine-learning algorithm for identification of resting-state networks on an individual basis. Network maps were uploaded to the clinical imaging and surgical navigation systems. Patient demographic and clinical characteristics, including need for sedation during imaging and use of task-based fMRI, were also recorded. RESULTS Twenty patients underwent rs-fMRI prior to craniotomy between December 2013 and June 2016. Their ages ranged from 1.9 to 18.4 years, and 12 were male. Five of the 20 patients also underwent task-based fMRI and one underwent awake craniotomy. Six patients required sedation to tolerate MRI acquisition, including resting-state sequences. Exemplar cases are presented including anatomical and resting-state functional imaging. CONCLUSIONS Resting-state fMRI is a rapidly advancing field of study allowing for whole brain analysis by a noninvasive modality. It is applicable to a wide range of patients and effective even under general anesthesia. The nature of resting

  20. Field experiment provides ground truth for surface nuclear magnetic resonance measurement

    Science.gov (United States)

    Knight, R.; Grunewald, E.; Irons, T.; Dlubac, K.; Song, Y.; Bachman, H.N.; Grau, B.; Walsh, D.; Abraham, J.D.; Cannia, J.

    2012-01-01

    The need for sustainable management of fresh water resources is one of the great challenges of the 21st century. Since most of the planet's liquid fresh water exists as groundwater, it is essential to develop non-invasive geophysical techniques to characterize groundwater aquifers. A field experiment was conducted in the High Plains Aquifer, central United States, to explore the mechanisms governing the non-invasive Surface NMR (SNMR) technology. We acquired both SNMR data and logging NMR data at a field site, along with lithology information from drill cuttings. This allowed us to directly compare the NMR relaxation parameter measured during logging,T2, to the relaxation parameter T2* measured using the SNMR method. The latter can be affected by inhomogeneity in the magnetic field, thus obscuring the link between the NMR relaxation parameter and the hydraulic conductivity of the geologic material. When the logging T2data were transformed to pseudo-T2* data, by accounting for inhomogeneity in the magnetic field and instrument dead time, we found good agreement with T2* obtained from the SNMR measurement. These results, combined with the additional information about lithology at the site, allowed us to delineate the physical mechanisms governing the SNMR measurement. Such understanding is a critical step in developing SNMR as a reliable geophysical method for the assessment of groundwater resources.

  1. Tripling of CO2 laser radiation in DBr, DCl and Se. Final technical report, 1 May 1977--31 Jan 1979

    International Nuclear Information System (INIS)

    Yoder, M.J.

    1979-03-01

    This report discusses frequency tripling of CO 2 lasers in deuterium chloride (DCl), deuterium bromide (DBr), and selenium (Se) gases. Theoretical tripling equations are reviewed and summarized. Third order nonlinear susceptibilities, chi/sup (3)/, for DCl, DBr and Se are calculated. Experimental measurements of frequency tripling in high pressure DCl and DBr are discussed. Resonantly enhanced four-wave sum-frequency generation in Se using simultaneous 9.5 and 10.6 μm TEA CO 2 laser pulses is demonstrated. The necessary selenium vapor density is generated in a shock tube. All of the experiments are in relatively good agreement with theory and results in chi /sup (3)/ values of 1.4 x 10 -37 ESU for DBr, 2.0 x 10 -36 for DCl and 1.1 x 10 -33 for Se (at 2000 0 K). Scaling equations are discussed which predict frequency conversion efficiencies of > 50% in DCl and Se using gigawatt power, nanosecond pulsed CO 2 lasers and reasonably sized conversion cells

  2. Geodynamical simulation of the RRF triple junction

    Science.gov (United States)

    Wang, Z.; Wei, D.; Liu, M.; Shi, Y.; Wang, S.

    2017-12-01

    Triple junction is the point at which three plate boundaries meet. Three plates at the triple junction form a complex geological tectonics, which is a natural laboratory to study the interactions of plates. This work studies a special triple junction, the oceanic transform fault intersects the collinear ridges with different-spreading rates, which is free of influence of ridge-transform faults and nearby hotspots. First, we build 3-D numerical model of this triple junction used to calculate the stead-state velocity and temperature fields resulting from advective and conductive heat transfer. We discuss in detail the influence of the velocity and temperature fields of the triple junction from viscosity, spreading rate of the ridge. The two sides of the oceanic transform fault are different sensitivities to the two factors. And, the influence of the velocity mainly occurs within 200km of the triple junction. Then, we modify the model by adding a ridge-transform fault to above model and directly use the velocity structure of the Macquarie triple junction. The simulation results show that the temperature at both sides of the oceanic transform fault decreases gradually from the triple junction, but the temperature difference between the two sides is a constant about 200°. And, there is little effect of upwelling velocity away from the triple junction 100km. The model results are compared with observational data. The heat flux and thermal topography along the oceanic transform fault of this model are consistent with the observed data of the Macquarie triple junction. The earthquakes are strike slip distributed along the oceanic transform fault. Their depths are also consistent with the zone of maximum shear stress. This work can help us to understand the interactions of plates of triple junctions and help us with the foundation for the future study of triple junctions.

  3. Fast wave ion cyclotron resonance heating experiments on the Alcator C tokamak

    International Nuclear Information System (INIS)

    Shepard, T.D.

    1988-09-01

    Minority regime fast wave ICRF heating experiments have been conducted on the Alcator C tokamak at rf power levels sufficient to produce significant changes in plasma properties, and in particular to investigate the scaling to high density of the rf heating efficiency. Up to 450 kW of rf power at frequency f = 180 MHz, was injected into plasmas composed of deuterium majority and hydrogen minority ion species at magnetic field B 0 = 12 T, density 0.8 ≤ /bar n/sub e// ≤ 5 /times/ 10 20 m -3 , ion temperature T/sub D/(0) /approximately/ 1 keV, electron temperature T/sub e/(0) /approximately/ 1.5--2.5 keV, and minority concentration 0.25 /approx lt/ /eta/sub H// ≤ 8%. Deuterium heating ΔT/sub D/(0) = 400 eV was observed at /bar n/sub e// = 1 /times/ 10 20 m -3 , with smaller temperature increases at higher density. However, there was no significant change in electron temperature and the minority temperatures were insufficient to account for the launched rf power. Minority concentration scans indicated most efficient deuterium heating at the lowest possible concentration, in apparent contradiction with theory. Incremental heating /tau/sub inc// /equivalent to/ ΔW/ΔP up to 5 ms was independent of density, in spite of theoretical predictions of favorable density scaling of rf absorption and in stark contrast to Ohmic confinement times /tau/sub E// /equivalent to/ W/P. After accounting for mode conversion and minority losses due to toroidal field ripple, unconfined orbits, asymmetric drag, neoclassical and sawtooth transport, and charge-exchange, it was found that the losses as well as the net power deposition on deuterium do scale very favorably with density. Nevertheless, when the net rf and Ohmic powers deposited on deuterium are compared, they are found to be equally efficient at heating the deuterium. 139 refs

  4. SU-E-J-181: Magnetic Resonance Image-Guided Radiation Therapy Workflow: Initial Clinical Experience

    International Nuclear Information System (INIS)

    Green, O; Kashani, R; Santanam, L; Wooten, H; Li, H; Rodriguez, V; Hu, Y; Mutic, S; Hand, T; Victoria, J; Steele, C

    2014-01-01

    Purpose: The aims of this work are to describe the workflow and initial clinical experience treating patients with an MRI-guided radiotherapy (MRIGRT) system. Methods: Patient treatments with a novel MR-IGRT system started at our institution in mid-January. The system consists of an on-board 0.35-T MRI, with IMRT-capable delivery via doubly-focused MLCs on three 60 Co heads. In addition to volumetric MR-imaging, real-time planar imaging is performed during treatment. So far, eleven patients started treatment (six finished), ranging from bladder to lung SBRT. While the system is capable of online adaptive radiotherapy and gating, a conventional workflow was used to start, consisting of volumetric imaging for patient setup using visible tumor, evaluation of tumor motion outside of PTV on cine images, and real-time imaging. Workflow times were collected and evaluated to increase efficiency and evaluate feasibility of adding the adaptive and gating features while maintaining a reasonable patient throughput. Results: For the first month, physicians attended every fraction to provide guidance on identifying the tumor and an acceptable level of positioning and anatomical deviation. Average total treatment times (including setup) were reduced from 55 to 45 min after physician presence was no longer required and the therapists had learned to align patients based on soft-tissue imaging. Presently, the source strengths were at half maximum (7.7K Ci each), therefore beam-on times will be reduced after source replacement. Current patient load is 10 per day, with increase to 25 anticipated in the near future. Conclusion: On-board, real-time MRI-guided RT has been incorporated into clinical use. Treatment times were kept to reasonable lengths while including volumetric imaging, previews of tumor movement, and physician evaluation. Workflow and timing is being continuously evaluated to increase efficiency. In near future, adaptive and gating capabilities of the system will be

  5. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    International Nuclear Information System (INIS)

    Noel, Cory V.; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh; Moffett, Brady

    2017-01-01

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  6. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  7. Electron spin resonance in neutron-irradiated graphite. Dependence on temperature and effect of annealing; Resonance paramagnetique du graphite irradie aux neutrons. Variation en fonction de la temperature et experiences de recuit

    Energy Technology Data Exchange (ETDEWEB)

    Kester, T [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires, Laboratoire de resonance magnetique

    1967-09-01

    The temperature dependence of the electron spin resonance signal from neutron irradiated graphite has been studied. The results lead to an interpretation of the nature of the paramagnetic centers created by irradiation. In annealing experiments on graphite samples, which had been irradiated at low temperature, two annealing peaks and one anti-annealing peak were found. Interpretations are proposed for these peaks. (author) [French] Le graphite irradie aux neutrons a ete etudie par resonance paramagnetique electronique en fonction de la temperature. La nature des centres paramagnetiques crees par irradiation est interpretee a l'aide des resultats. Des experiences de recuit sur des echantillons de graphite irradie a 77 deg. K ont permis de mettre en evidence deux pics de recuit et un pic d'anti-recuit, pour lesquels des interpretations sont proposees. (auteur)

  8. (e,e'f) coincidence experiments for fission decay of giant resonances in 235,238U

    International Nuclear Information System (INIS)

    Weber, T.; Heil, R.D.; Kneissl, U.; Pecho, W.; Wilke, W.; Emrich, H.J.; Kihm, T.; Knoepfle, K.T.

    1988-01-01

    Extending previous work on 238 U, 235 U(e,e'f) coincidence data were taken at 4 momentum transfers yielding both E1, E2/E0 and E3 form factors and the respective multipole strength distributions in the giant resonance region of 238 U (4 x x /Γ a is obtained as a function of excitation energy for separated multipoles. The giant E2 resonance exhibits an increased symmetric fission contribution compared to E1 and E3 resonances. (orig.)

  9. Guided search for triple conjunctions.

    Science.gov (United States)

    Nordfang, Maria; Wolfe, Jeremy M

    2014-08-01

    A key tenet of feature integration theory and of related theories such as guided search (GS) is that the binding of basic features requires attention. This would seem to predict that conjunctions of features of objects that have not been attended should not influence search. However, Found (1998) reported that an irrelevant feature (size) improved the efficiency of search for a Color × Orientation conjunction if it was correlated with the other two features across the display, as compared to the case in which size was not correlated with color and orientation features. We examined this issue with somewhat different stimuli. We used triple conjunctions of color, orientation, and shape (e.g., search for a red, vertical, oval-shaped item). This allowed us to manipulate the number of features that each distractor shared with the target (sharing) and it allowed us to vary the total number of distractor types (and, thus, the number of groups of identical items: grouping). We found that these triple conjunction searches were generally very efficient--producing very shallow Reaction Time × Set Size slopes, consistent with strong guidance by basic features. Nevertheless, both of the variables, sharing and grouping, modulated performance. These influences were not predicted by previous accounts of GS; however, both can be accommodated in a GS framework. Alternatively, it is possible, though not necessary, to see these effects as evidence for "preattentive binding" of conjunctions.

  10. ACA and the Triple Aim: Musings of a Health Care Actuary.

    Science.gov (United States)

    McCarthy, Mac

    2015-01-01

    In 2008, the Institute for Healthcare Improvement (IHI) promulgated the Triple Aim, which advocates simultaneous improvements in patient experiences, improved population health and lower cost per capita. In 2010, the Patient Protection and Affordable Care Act (ACA) promised quality, affordable health care for all Americans. It's fair to assume that the framers of ACA were aware of the Triple Aim, and it is likely that much of ACA was heavily influenced by IHI's positions. So it is reasonable, from time to time, to assess ACA's impact on health care against the Triple Aim principles.

  11. Triple and quartic gauge boson couplings at the LHC

    CERN Document Server

    Kupco, Alexander; The ATLAS collaboration

    2017-01-01

    This report at the conference Physics in Collision 2017 reviews recent results from the ATLAS and CMS experiments on production of gauge boson pairs, triples, and vector boson scattering (VBS) processes. Large datasets from LHC proton-proton collisions at $\\sqrt{s}=8$ and $13\\,\\mathrm{TeV}$ allowed the first observations of rare processes: triboson production in channel $Z\\gamma\\gamma$ at $\\sqrt{s}=8\\,\\mathrm{TeV}$ and VBS of same signed WW at $\\sqrt{s}=13\\,\\mathrm{TeV}$. Both experiments observe good agreement with the Standard model (SM) predictions. The data were used to set new limits on anomalous triple and quartic gauge couplings not present in the SM.

  12. Design and fabrication of circular and rectangular components for electron-cyclotron-resonant heating of tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Felker, B.; Calderon, M.O.; Chargin, A.K.

    1983-01-01

    The electron-cyclotron-resonant heating (ECRH) systems of rectangular waveguides on Tandem Mirror Experiment-Upgrade (TMX-U) operated with a overall efficiency of 50%, each system using a 28-GHz, 200-kW pulsed gyrotron. We designed and built four circular-waveguide systems with greater efficiency and greater power-handling capabilities to replace the rectangular waveguides. Two of these circular systems, at the 5-kG second-harmonic heating locations, have a total transmission efficiency of >90%. The two systems at the 10-kG fundamental heating locations have a total transmission efficiency of 80%. The difference in efficiency is due to the additional components required to launch the microwaves in the desired orientation and polarization with respect to magnetic-field lines at the 10-kG points. These systems handle the total power available from each gyrotron but do not have the arcing limitation problem of the rectangular waveguide. Each system requires several complex components. The overall physical layout and the design considerations for the rectangular and circular waveguide components are described here

  13. High-resolution nuclear magnetic resonance measurements in inhomogeneous magnetic fields: A fast two-dimensional J-resolved experiment

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yuqing; Cai, Shuhui; Yang, Yu; Sun, Huijun; Lin, Yanqin, E-mail: linyq@xmu.edu.cn, E-mail: chenz@xmu.edu.cn; Chen, Zhong, E-mail: linyq@xmu.edu.cn, E-mail: chenz@xmu.edu.cn [Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005 (China); Lin, Yung-Ya [Department of Chemistry and Biochemistry, University of California, Los Angeles, California 90095 (United States)

    2016-03-14

    High spectral resolution in nuclear magnetic resonance (NMR) is a prerequisite for achieving accurate information relevant to molecular structures and composition assignments. The continuous development of superconducting magnets guarantees strong and homogeneous static magnetic fields for satisfactory spectral resolution. However, there exist circumstances, such as measurements on biological tissues and heterogeneous chemical samples, where the field homogeneity is degraded and spectral line broadening seems inevitable. Here we propose an NMR method, named intermolecular zero-quantum coherence J-resolved spectroscopy (iZQC-JRES), to face the challenge of field inhomogeneity and obtain desired high-resolution two-dimensional J-resolved spectra with fast acquisition. Theoretical analyses for this method are given according to the intermolecular multiple-quantum coherence treatment. Experiments on (a) a simple chemical solution and (b) an aqueous solution of mixed metabolites under externally deshimmed fields, and on (c) a table grape sample with intrinsic field inhomogeneity from magnetic susceptibility variations demonstrate the feasibility and applicability of the iZQC-JRES method. The application of this method to inhomogeneous chemical and biological samples, maybe in vivo samples, appears promising.

  14. Design and fabrication of circular and rectangular components for electron-cyclotron-resonant heating of tandem mirror experiment-upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Felker, B.; Calderon, M.O.; Chargin, A.K.; Coffield, F.E.; Lang, D.D.; Rubert, R.R.; Pedrotti, L.R.; Stallard, B.W.; Gallagher, N.C. Jr.; Sweeney, D.W.

    1983-11-18

    The electron-cyclotron-resonant heating (ECRH) systems of rectangular waveguides on Tandem Mirror Experiment-Upgrade (TMX-U) operated with a overall efficiency of 50%, each system using a 28-GHz, 200-kW pulsed gyrotron. We designed and built four circular-waveguide systems with greater efficiency and greater power-handling capabilities to replace the rectangular waveguides. Two of these circular systems, at the 5-kG second-harmonic heating locations, have a total transmission efficiency of >90%. The two systems at the 10-kG fundamental heating locations have a total transmission efficiency of 80%. The difference in efficiency is due to the additional components required to launch the microwaves in the desired orientation and polarization with respect to magnetic-field lines at the 10-kG points. These systems handle the total power available from each gyrotron but do not have the arcing limitation problem of the rectangular waveguide. Each system requires several complex components. The overall physical layout and the design considerations for the rectangular and circular waveguide components are described here.

  15. Search for high mass resonances in the dimuon channel using the muon spectrometer of the atlas experiment at CERN

    International Nuclear Information System (INIS)

    Helsens, C.

    2009-06-01

    This thesis covers the search of new neutral gauge bosons decaying into a pair of muons in the ATLAS detector. The Large Hadron Collider (LHC) at CERN will produce parton collisions with very high center of mass energy and may produce Z' predicted by many theories beyond the standard model. Such a resonance should be detected by the ATLAS experiment. For the direct search of Z' decaying into two muons, a small number of events is enough for its discovery, which is possible with the first data. We shall study in particular the effects of the muon spectrometer alignment on high p T tracks and on the Z' discovery potential in the ATLAS experiment. The discovery potentials computed with this method have been officially approved by the ATLAS collaboration and published. At the start of the LHC operation, the muon spectrometer alignment will not have reached the nominal performances. This analysis aims at optimizing the discovery potential of ATLAS for a Z' boson in this degraded initial conditions. The impact on track reconstruction of a degraded alignment is estimated with simulated high p T tracks. Results are given in terms of reconstruction efficiency, momentum and invariant mass resolutions, charge identification and sensitivity to discovery or exclusion. With the first data, an analysis using only the muon spectrometer in stand alone mode will be very useful. Finally, a study on how to determine the initial geometry of the spectrometer (needed for its absolute alignment) is performed. This study uses straight tracks without a magnetic field and also calculates the beam time necessary for reaching a given accuracy of the alignment system. (author)

  16. Limited magnetic resonance imaging in low back pain instead of plain radiographs: Experience with first 1000 cases

    International Nuclear Information System (INIS)

    McNally, Eugene G.; Wilson, David J.; Ostlere, Simon J.

    2001-01-01

    AIM: We report our experience with the first 1000 patients with non-traumatic low back pain (LBP) without radiculopathy undergoing limited sequence magnetic resonance imaging (MRI) instead of plain radiography. METHODS: Between January 1996 and December 1998, 1042 patients with low back pain unresponsive to conservative treatment were examined using a limited MR protocol comprising sagittal T1-weighted and STIR imaging. Plain radiographs were not performed. RESULTS: Malignancy, infection, vertebral fracture, spondylitis, pars defects and cord tumours were detected in 20%. Of the 82 osteoporotic vertebral fractures detected, 51 (62%) were recent and 31 had normal marrow signal indicating that they were old. Eighty pars defects were identified, 45(56%) had spondylolisthesis, 29(37%) were undisplaced and 6 (7%) had pars oedema only. Neoplastic disease was found in 17(8%) of which none was suspected before imaging. Benign neoplastic diseases such as vertebral AVM/haemangiomata were excluded. Twenty-one patients had a variety of disorders including ankylosing spondylitis (7), large vessel aneurysm (3), discitis (2), ovarian cyst (2), sequestered disc (2), sacral insufficiency fracture (2) and one patient each with burst fracture, retroperitoneal haematoma and a previously unsuspected horseshoe kidney. CONCLUSION: The majority of patients with LBP are best assessed clinically and imaging is usually not required. In patients with worrying symptoms, MRI with a limited protocol detects a greater number of abnormalities than previously reported studies using plain radiographs and has replaced plain radiography in our hospital. We report our experience with the first 1000 patients and highlight issues such as protocols, detection rates and communication issues. McNally E.G. et al. (2001)

  17. Reconstruction and identification of muons in the experiment DO, study of the resonant production of s-leptons

    International Nuclear Information System (INIS)

    Deliot, F.

    2002-04-01

    In the framework of supersymmetric models with R-parity violation, supersymmetric particles can be singly produced. If the λ' 211 coupling is the dominant one, muon s-neutrino or a s-muon can be resonantly produced at the Tevatron and lead to tri-lepton (with two muons) or like sign dimuon final states. In this thesis, the discovery potential for these signals at Tevatron Run II has been studied in the framework of the minimal supergravity model. Those processes reach a high sensitivity on the model parameters m 0 and m 1/2 and allow to reconstruct the masses for the superparticles involved in the decay chain. Tevatron Run II has begun in 2001 after important upgrades in the accelerator complex and in the D0 experiment. In particular the muon spectrometer has been modified. The D0 experiment is in the calibration and alignment phase. The second part of the work presented in this thesis covers the muon reconstruction and identification. The track reconstruction in the muon spectrometer is performed with a fit taking into account magnetic field, energy loss and multiple scattering in the iron toroid. This method gives a momentum resolution limited for low momentum tracks at 20% due to multiple scattering in the toroid. These tracks and its error matrix are then propagated through the calorimeter and combined with the inner tracker tracks. The first Run II data recorded by D0 has allowed to compute the trigger efficiency and to valid the muon identification algorithms which were, for this thesis, entirely based on muon spectrometer informations. The first J/ψ studies show that the reconstruction works correctly and that the identification criteria are preferment. (author)

  18. Methods for sequential resonance assignment in solid, uniformly 13C, 15N labelled peptides: Quantification and application to antamanide

    International Nuclear Information System (INIS)

    Detken, Andreas; Hardy, Edme H.; Ernst, Matthias; Kainosho, Masatsune; Kawakami, Toru; Aimoto, Saburo; Meier, Beat H.

    2001-01-01

    The application of adiabatic polarization-transfer experiments to resonance assignment in solid, uniformly 13 C- 15 N-labelled polypeptides is demonstrated for the cyclic decapeptide antamanide. A homonuclear correlation experiment employing the DREAM sequence for adiabatic dipolar transfer yields a complete assignment of the C α and aliphatic side-chain 13 C resonances to amino acid types. The same information can be obtained from a TOBSY experiment using the recently introduced P9 1 12 TOBSY sequence, which employs the J couplings as a transfer mechanism. A comparison of the two methods is presented. Except for some aromatic phenylalanine resonances, a complete sequence-specific assignment of the 13 C and 15 N resonances in antamanide is achieved by a series of selective or broadband adiabatic triple-resonance experiments. Heteronuclear transfer by adiabatic-passage Hartmann-Hahn cross polarization is combined with adiabatic homonuclear transfer by the DREAM and rotational-resonance tickling sequences into two- and three-dimensional experiments. The performance of these experiments is evaluated quantitatively

  19. Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

    Science.gov (United States)

    Polzin, Kurt A.; Ratcliffe, Alicia C.

    2018-01-01

    The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the

  20. Holonomy loops, spectral triples and quantum gravity

    DEFF Research Database (Denmark)

    Johannes, Aastrup; Grimstrup, Jesper Møller; Nest, Ryszard

    2009-01-01

    We review the motivation, construction and physical interpretation of a semi-finite spectral triple obtained through a rearrangement of central elements of loop quantum gravity. The triple is based on a countable set of oriented graphs and the algebra consists of generalized holonomy loops...

  1. Spectral triples and the geometry of fractals

    DEFF Research Database (Denmark)

    Christensen, Erik; Ivan, Cristina; Schroe, Elmar

    2012-01-01

    It is shown that one can construct a spectral triple for the Sierpinski gasket such that it represents any given K-homology class, On the other hand if the geodesic distance and the dimension has to be part of the data from the triple, there are certain restriction....

  2. Baryon Resonances

    International Nuclear Information System (INIS)

    Oset, E.; Sarkar, S.; Sun Baoxi; Vicente Vacas, M.J.; Ramos, A.; Gonzalez, P.; Vijande, J.; Martinez Torres, A.; Khemchandani, K.

    2010-01-01

    In this talk I show recent results on how many excited baryon resonances appear as systems of one meson and one baryon, or two mesons and one baryon, with the mesons being either pseudoscalar or vectors. Connection with experiment is made including a discussion on old predictions and recent results for the photoproduction of the Λ(1405) resonance, as well as the prediction of one 1/2 + baryon state around 1920 MeV which might have been seen in the γp→K + Λ reaction.

  3. A modified strategy for sequence specific assignment of protein NMR spectra based on amino acid type selective experiments

    International Nuclear Information System (INIS)

    Schubert, Mario; Labudde, Dirk; Leitner, Dietmar; Oschkinat, Hartmut; Schmieder, Peter

    2005-01-01

    The determination of the three-dimensional structure of a protein or the study of protein-ligand interactions requires the assignment of all relevant nuclei as an initial step. This is nowadays almost exclusively performed using triple-resonance experiments. The conventional strategy utilizes one or more pairs of three dimensional spectra to obtain redundant information and thus reliable assignments. Here, a modified strategy for obtaining sequence specific assignments based on two dimensional amino acid type selective triple-resonance experiments is proposed. These experiments can be recorded with good resolution in a relatively short time. They provide very specific and redundant information, in particular on sequential connectivities, that drastically increases the ease and reliability of the assignment procedure, done either manually or in an automated fashion. The new strategy is demonstrated with the protein domain PB1 from yeast CDC24p

  4. Triple Test in Carcinoma Breast

    Science.gov (United States)

    Sameer; Mukherjee, Arindam

    2014-01-01

    Introduction: The commonest clinical presentation in majority of breast pathology is a lump. A definite diagnosis of breast lump is very important for the surgeon to decide on the final course of treatment and also saves the patient from unnecessary physical, emotional and psychological trauma if there is a definite preoperative diagnosis of benign lesion. The present study was done to evaluate the effectiveness and relevance of “TRIPLE TEST”in diagnosis of carcinoma breast in rural labour class population. Materials and Methods: The present study was a prospective study conducted on patients over 35 years of age having palpable breast lumps presenting in the out patient department of general surgery, ESI Hospital Basaidarapur New Delhi, India. The duration of study was from May 2007 to June 2009 and a total of 100 cases were studied. Each patient was subjected to a detailed history, clinical breast examination ,diagnostic mammography and FNAC. In this study, the results of each modality was divided in three groups: benign, suspicious and malignant. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of each test was calculated individually and as combined. Result: Out of 100 patients enrolled in this study, 60 cases were benign and 40 cases were of malignant breast disease. The age of patients with carcinoma breast in the series varied from 35 years to 70 years. The highest incidence of malignancy noted was 30% in 41-50 years age group (4th decade) followed by 27.5% in 51-60 years age group (5th decade). The sensitivity of clinical examination was found to be 75%, specificity was 83.3%, positive predictive value (PPV) of 75% and diagnostic accuracy of 80%. The sensitivity, specificity, positive predictive value and diagnostic accuracy of mammography was calculated and was found to be 94.9% , 90% , 86% and 92% respectively. The sensitivity, specificity, positive predictive value and diagnostic accuracy of

  5. NIM Realization of the Gallium Triple Point

    Science.gov (United States)

    Xiaoke, Yan; Ping, Qiu; Yuning, Duan; Yongmei, Qu

    2003-09-01

    In the last three years (1999 to 2001), the gallium triple-point cell has been successfully developed, and much corresponding research has been carried out at the National Institute of Metrology (NIM), Beijing, China. This paper presents the cell design, apparatus and procedure for realizing the gallium triple point, and presents studies on the different freezing methods. The reproducibility is 0.03 mK, and the expanded uncertainty of realization of the gallium triple point is evaluated to be 0.17 mK (p=0.99, k=2.9). Also, the reproducibility of the gallium triple point was compared with that of the triple point of water.

  6. Search for high mass dilepton resonances in pp collisions at $\\sqrt{s}$=7 TeV with the ATLAS experiment

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdelalim, Ahmed Ali; Abdesselam, Abdelouahab; Abdinov, Ovsat; Abi, Babak; Abolins, Maris; Abramowicz, Halina; Abreu, Henso; Acerbi, Emilio; Acharya, Bobby Samir; Adams, David; Addy, Tetteh; Adelman, Jahred; Aderholz, Michael; Adomeit, Stefanie; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Akesson, Torsten Paul; Akimoto, Ginga; Akimov, Andrei; Akiyama, Kunihiro; Alam, Mohammad; Alam, Muhammad Aftab; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alessandria, Franco; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Aliyev, Magsud; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alviggi, Mariagrazia; Amako, Katsuya; Amaral, Pedro; Amelung, Christoph; Ammosov, Vladimir; Amorim, Antonio; Amoros, Gabriel; Amram, Nir; Anastopoulos, Christos; Andeen, Timothy; Anders, Christoph Falk; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Andrieux, Marie-Laure; Anduaga, Xabier; Angerami, Aaron; Anghinolfi, Francis; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonelli, Stefano; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoun, Sahar; Aperio Bella, Ludovica; Apolle, Rudi; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Archambault, John-Paul; Arfaoui, Samir; Arguin, Jean-Francois; Arik, Engin; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnault, Christian; Artamonov, Andrei; Artoni, Giacomo; Arutinov, David; Asai, Shoji; Asfandiyarov, Ruslan; Ask, Stefan; Asman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astbury, Alan; Astvatsatourov, Anatoli; Atoian, Grigor; Aubert, Bernard; Auerbach, Benjamin; Auge, Etienne; Augsten, Kamil; Aurousseau, Mathieu; Austin, Nicholas; Avramidou, Rachel Maria; Axen, David; Ay, Cano; Azuelos, Georges; Azuma, Yuya; Baak, Max; Baccaglioni, Giuseppe; Bacci, Cesare; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Bachy, Gerard; Backes, Moritz; Backhaus, Malte; Badescu, Elisabeta; Bagnaia, Paolo; Bahinipati, Seema; Bai, Yu; Bailey, David; Bain, Travis; Baines, John; Baker, Oliver Keith; Baker, Mark; Baker, Sarah; Baltasar Dos Santos Pedrosa, Fernando; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Bansil, Hardeep Singh; Barak, Liron; Baranov, Sergei; Barashkou, Andrei; Galtieri, Angela Barbaro; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barr, Alan; Barreiro, Fernando; Barreiro Guimaraes da Costa, Joao; Barrillon, Pierre; Bartoldus, Rainer; Barton, Adam Edward; Bartsch, Detlef; Bartsch, Valeria; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Battistoni, Giuseppe; Bauer, Florian; Bawa, Harinder Singh; Beare, Brian; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Andrew; Beddall, Ayda; Bedikian, Sourpouhi; Bednyakov, Vadim; Bee, Christopher; Begel, Michael; Behar Harpaz, Silvia; Behera, Prafulla; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Beloborodova, Olga; Belotskiy, Konstantin; Beltramello, Olga; Ben Ami, Sagi; Benary, Odette; Benchekroun, Driss; Benchouk, Chafik; Bendel, Markus; Benedict, Brian Hugues; Benekos, Nektarios; Benhammou, Yan; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jurg; Bernardet, Karim; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertin, Antonio; Bertinelli, Francesco; Bertolucci, Federico; Besana, Maria Ilaria; Besson, Nathalie; Bethke, Siegfried; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Bitenc, Urban; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blocker, Craig; Blocki, Jacek; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Boddy, Christopher Richard; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Boser, Sebastian; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bogouch, Andrei; Bohm, Christian; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bolnet, Nayanka Myriam; Bona, Marcella; Bondarenko, Valery; Boonekamp, Maarten; Boorman, Gary; Booth, Chris; Booth, Peter; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borroni, Sara; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Botterill, David; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boulahouache, Chaouki; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozhko, Nikolay; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Braem, Andre; Branchini, Paolo; Brandenburg, George; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brelier, Bertrand; Bremer, Johan; Brenner, Richard; Bressler, Shikma; Breton, Dominique; Brett, Nicolas; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Brodbeck, Timothy; Brodet, Eyal; Broggi, Francesco; Bromberg, Carl; Brooijmans, Gustaaf; Brooks, William; Brown, Gareth; Brubaker, Erik; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Buanes, Trygve; Bucci, Francesca; Buchanan, James; Buchanan, Norman; Buchholz, Peter; Buckingham, Ryan; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Budick, Burton; Buscher, Volker; Bugge, Lars; Buira-Clark, Daniel; Buis, Ernst-Jan; Bulekov, Oleg; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butin, Francois; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Buttinger, William; Byatt, Tom; Cabrera Urban, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Caloi, Rita; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camard, Arnaud; Camarri, Paolo; Cambiaghi, Mario; Cameron, David; Cammin, Jochen; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Capasso, Luciano; Garrido, Maria Del Mar Capeans; Caprini, Irinel; Caprini, Mihai; Capriotti, Daniele; Capua, Marcella; Caputo, Regina; Caramarcu, Costin; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carpentieri, Carmen; Montoya, German D.Carrillo; Carter, Antony; Carter, Janet; Carvalho, Joao; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Caso, Carlo; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Cataneo, Fernando; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cauz, Diego; Cavallari, Alvise; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Cazzato, Antonio; Ceradini, Filippo; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Cevenini, Francesco; Chafaq, Aziz; Chakraborty, Dhiman; Chan, Kevin; Chapleau, Bertrand; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Li; Chen, Shenjian; Chen, Tingyang; Chen, Xin; Cheng, Shaochen; Cheplakov, Alexander; Chepurnov, Vladimir; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciba, Krzysztof; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciobotaru, Matei Dan; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Ciubancan, Mihai; Clark, Allan G.; Clark, Philip James; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Clifft, Roger; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H.; Coe, Paul; Cogan, Joshua Godfrey; Coggeshall, James; Cogneras, Eric; Cojocaru, Claudiu; Colas, Jacques; Colijn, Auke-Pieter; Collard, Caroline; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colon, German; Comune, Gianluca; Conde Muino, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Michele; Constantinescu, Serban; Conta, Claudio; Conventi, Francesco; Cook, James; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cooper-Smith, Neil; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, Maria Jose; Costanzo, Davide; Costin, Tudor; Cote, David; Coura Torres, Rodrigo; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Crescioli, Francesco; Cristinziani, Markus; Crosetti, Giovanni; Crupi, Roberto; Crepe-Renaudin, Sabine; Cuenca Almenar, Cristobal; Donszelmann, Tulay Cuhadar; Cuneo, Stefano; Curatolo, Maria; Curtis, Chris; Cwetanski, Peter; Czirr, Hendrik; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Rocha Gesualdi Mello, Aline; Da Silva, Paulo Vitor; Da Via, Cinzia; Dabrowski, Wladyslaw; Dahlhoff, Andrea; Dai, Tiesheng; Dallapiccola, Carlo; Dallison, Steve; Dam, Mogens; Dameri, Mauro; Damiani, Daniel; Danielsson, Hans Olof; Dankers, Reinier; Dannheim, Dominik; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Daum, Cornelis; Dauvergne, Jean-Pierre; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Merlin; Davison, Adam; Dawe, Edmund; Dawson, Ian; Dawson, John; Daya, Rozmin; De, Kaushik; De Asmundis, Riccardo; De Castro, Stefano; De Castro Faria Salgado, Pedro; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; de la Taille, Christophe; de la Torre, Hector; De Lotto, Barbara; De Mora, Lee; De Nooij, Lucie; De Oliveira Branco, Miguel; De Pedis, Daniele; de Saintignon, Paul; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; de Vivie De Regie, Jean-Baptiste; Dean, Simon; Dedovich, Dmitri; Degenhardt, James; Dehchar, Mohamed; Deile, Mario; del Papa, Carlo; del Peso, Jose; del Prete, Tarcisio; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delpierre, Pierre; Delruelle, Nicolas; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Devetak, Erik; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diblen, Faruk; Diehl, Edward; Dietl, Hans; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Yagci, Kamile Dindar; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djilkibaev, Rashid; Djobava, Tamar; Barros do Vale, Maria Aline; Do Valle Wemans, Andre; Doan, Thi Kieu Oanh; Dobbs, Matt; Dobinson, Robert; Dobos, Daniel; Dobson, Ellie; Dobson, Marc; Dodd, Jeremy; Dogan, Ozgen Berkol; Doglioni, Caterina; Doherty, Tom; Doi, Yoshikuni; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donadelli, Marisilvia; Donega, Mauro; Donini, Julien; Dopke, Jens; Doria, Alessandra; dos Anjos, Andre; Dosil, Mireia; Dotti, Andrea; Dova, Maria-Teresa; Dowell, John; Doxiadis, Alexander; Doyle, Tony; Drasal, Zbynek; Drees, Jurgen; Dressnandt, Nandor; Drevermann, Hans; Driouichi, Chafik; Dris, Manolis; Drohan, Janice; Dubbert, Jorg; Dubbs, Tim; Dube, Sourabh; Duchovni, Ehud; Duckeck, Guenter; Dudarev, Alexey; Dudziak, Fanny; Duhrssen, Michael; Duerdoth, Ian; Duflot, Laurent; Dufour, Marc-Andre; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Dydak, Friedrich; Dzahini, Daniel; Duren, Michael; Ebenstein, William; Ebke, Johannes; Eckert, Simon; Eckweiler, Sebastian; Edmonds, Keith; Edwards, Clive; Ehrenfeld, Wolfgang; Ehrich, Thies; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Ely, Robert; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Eppig, Andrew; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienne, Francois; Etienvre, Anne-Isabelle; Etzion, Erez; Evangelakou, Despoina; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Facius, Katrine; Fakhrutdinov, Rinat; Falciano, Speranza; Falou, Alain; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrington, Sinead; Farthouat, Philippe; Fasching, Damon; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Favareto, Andrea; Fayard, Louis; Fazio, Salvatore; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Ivan; Fedorko, Woiciech; Fehling-Kaschek, Mirjam; Feligioni, Lorenzo; Fellmann, Denis; Felzmann, Ulrich; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Ferland, Jonathan; Fernandes, Bruno; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferrer, Antonio; Ferrer, Maria Lorenza; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipcic, Andrej; Filippas, Anastasios; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fischer, Peter; Fisher, Matthew; Fisher, Steve; Flammer, Joachim; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Flores Castillo, Luis; Flowerdew, Michael; Fohlisch, Florian; Fokitis, Manolis; Fonseca Martin, Teresa; Forbush, David Alan; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Foster, Joe; Fournier, Daniel; Foussat, Arnaud; Fowler, Andrew; Fowler, Ken; Fox, Harald; Francavilla, Paolo; Franchino, Silvia; Francis, David; Frank, Tal; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; French, Sky; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallas, Manuel; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Galyaev, Eugene; Gan, K.K.; Gao, Yongsheng; Gapienko, Vladimir; Gaponenko, Andrei; Garberson, Ford; Garcia-Sciveres, Maurice; Garcia, Carmen; Garcia Navarro, Jose Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Garvey, John; Gatti, Claudio; Gaudio, Gabriella; Gaumer, Olivier; Gaur, Bakul; Gauthier, Lea; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gayde, Jean-Christophe; Gazis, Evangelos; Ge, Peng; Gee, Norman; Geerts, Daniel Alphonsus Adrianus; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Gemmell, Alistair; Genest, Marie-Helene; Gentile, Simonetta; George, Matthias; George, Simon; Gerlach, Peter; Gershon, Avi; Geweniger, Christoph; Ghazlane, Hamid; Ghez, Philippe; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gieraltowski, Gerry; Gilbert, Laura; Gilchriese, Murdock; Gilewsky, Valentin; Gillberg, Dag; Gillman, Tony; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Giugni, Danilo; Giusti, Paolo; Gjelsten, Borge Kile; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Gopfert, Thomas; Goeringer, Christian; Gossling, Claus; Gottfert, Tobias; Goldfarb, Steven; Goldin, Daniel; Golling, Tobias; Golovnia, Serguei; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Goncalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; Gonidec, Allain; Gonzalez, Saul; Gonzalez de la Hoz, Santiago; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorisek, Andrej; Gornicki, Edward; Gorokhov, Serguei; Goryachev, Vladimir; Gosdzik, Bjoern; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gouanere, Michel; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Grabowska-Bold, Iwona; Grabski, Varlen; Grafstrom, Per; Grah, Christian; Grahn, Karl-Johan; Grancagnolo, Francesco; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Grebenyuk, Oleg; Greenfield, Debbie; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregor, Ingrid-Maria; Grenier, Philippe; Griesmayer, Erich; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grinstein, Sebastian; Gris, Philippe Luc Yves; Grishkevich, Yaroslav; Grivaz, Jean-Francois; Grognuz, Joel; Groh, Manfred; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Gruwe, Magali; Grybel, Kai; Guarino, Victor; Guest, Daniel; Guicheney, Christophe; Guida, Angelo; Guillemin, Thibault; Guindon, Stefan; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Guo, Jun; Gupta, Ambreesh; Gusakov, Yury; Gushchin, Vladimir; Gutierrez, Andrea; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hackenburg, Robert; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Hahn, Ferdinand; Haider, Stefan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haller, Johannes; Hamacher, Klaus; Hamal, Petr; Hamilton, Andrew; Hamilton, Samuel; Han, Hongguang; Han, Liang; Hanagaki, Kazunori; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, Christian Johan; Hansen, John Renner; Hansen, Jorgen Beck; Hansen, Jorn Dines; Hansen, Peter Henrik; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harper, Devin; Harrington, Robert; Harris, Orin; Harrison, Karl; Hartert, Jochen; Hartjes, Fred; Haruyama, Tomiyoshi; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Hatch, Mark; Hauff, Dieter; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawes, Brian; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Donovan; Hayakawa, Takashi; Hayden, Daniel; Hayward, Helen; Haywood, Stephen; Hazen, Eric; He, Mao; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heldmann, Michael; Heller, Mathieu; Hellman, Sten; Helsens, Clement; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Henry-Couannier, Frederic; Hensel, Carsten; Henss, Tobias; Hernandez Jimenez, Yesenia; Herrberg, Ruth; Hershenhorn, Alon David; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hessey, Nigel; Hidvegi, Attila; Higon-Rodriguez, Emilio; Hill, Daniel; Hill, John; Hill, Norman; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Holder, Martin; Holmes, Alan; Holmgren, Sven-Olof; Holy, Tomas; Holzbauer, Jenny; Homma, Yasuhiro; Hooft van Huysduynen, Loek; Horazdovsky, Tomas; Horn, Claus; Horner, Stephan; Horton, Katherine; Hostachy, Jean-Yves; Hou, Suen; Houlden, Michael; Hoummada, Abdeslam; Howarth, James; Howell, David; Hristova, Ivana; Hrivnac, Julius; Hruska, Ivan; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Huang, Guang Shun; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Hughes-Jones, Richard; Huhtinen, Mika; Hurst, Peter; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibbotson, Michael; Ibragimov, Iskander; Ichimiya, Ryo; Iconomidou-Fayard, Lydia; Idarraga, John; Idzik, Marek; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Ilchenko, Yuri; Iliadis, Dimitrios; Imbault, Didier; Imhaeuser, Martin; Imori, Masatoshi; Ince, Tayfun; Inigo-Golfin, Joaquin; Ioannou, Pavlos; Iodice, Mauro; Ionescu, Gelu; Irles Quiles, Adrian; Ishii, Koji; Ishikawa, Akimasa; Ishino, Masaya; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Itoh, Yuki; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakubek, Jan; Jana, Dilip; Jankowski, Ernest; Jansen, Eric; Jantsch, Andreas; Janus, Michel; Jarlskog, Goran; Jeanty, Laura; Jelen, Kazimierz; Jen-La Plante, Imai; Jenni, Peter; Jeremie, Andrea; Jez, Pavel; Jezequel, Stephane; Jha, Manoj Kumar; Ji, Haoshuang; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Ge; Jin, Shan; Jinnouchi, Osamu; Joergensen, Morten Dam; Joffe, David; Johansen, Lars; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tegid; Jones, Tim; Jonsson, Ove; Joram, Christian; Jorge, Pedro; Joseph, John; Ju, Xiangyang; Juranek, Vojtech; Jussel, Patrick; Kabachenko, Vasily; Kabana, Sonja; Kaci, Mohammed; Kaczmarska, Anna; Kadlecik, Peter; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kaiser, Steffen; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kanno, Takayuki; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagoz, Muge; Karnevskiy, Mikhail; Karr, Kristo; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasmi, Azzedine; Kass, Richard; Kastanas, Alex; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kazanin, Vassili; Kazarinov, Makhail; Kazi, Sandor Istvan; Keates, James Robert; Keeler, Richard; Kehoe, Robert; Keil, Markus; Kekelidze, George; Kelly, Marc; Kennedy, John; Kenney, Christopher John; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kersevan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Ketterer, Christian; Khakzad, Mohsen; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Kholodenko, Anatoli; Khomich, Andrei; Khoo, Teng Jian; Khoriauli, Gia; Khovanskiy, Nikolai; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kilvington, Graham; Kim, Hyeon Jin; Kim, Min Suk; Kim, Peter; Kim, Shinhong; Kimura, Naoki; Kind, Oliver; King, Barry; King, Matthew; King, Robert Steven Beaufoy; Kirk, Julie; Kirsch, Guillaume; Kirsch, Lawrence; Kiryunin, Andrey; Kisielewska, Danuta; Kittelmann, Thomas; Kiver, Andrey; Kiyamura, Hironori; Kladiva, Eduard; Klaiber-Lodewigs, Jonas; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimentov, Alexei; Klingenberg, Reiner; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Kluth, Stefan; Kneringer, Emmerich; Knobloch, Juergen; Knoops, Edith B F G; Knue, Andrea; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Koblitz, Birger; Kocian, Martin; Kocnar, Antonin; Kodys, Peter; Koneke, Karsten; Konig, Adriaan; Koenig, Sebastian; Kopke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kokott, Thomas; Kolachev, Guennady; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollar, Daniel; Kollefrath, Michael; Kolya, Scott; Komar, Aston; Komaragiri, Jyothsna Rani; Kondo, Takahiko; Kono, Takanori; Kononov, Anatoly; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kootz, Andreas; Koperny, Stefan; Kopikov, Sergey; Korcyl, Krzysztof; Kordas, Kostantinos; Koreshev, Victor; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostyukhin, Vadim; Kotamaki, Miikka Juhani; Kotov, Sergey; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Henri; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasel, Olaf; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, James; Kreisel, Arik; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Kruger, Hans; Krumshteyn, Zinovii; Kruth, Andre; Kubota, Takashi; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kundu, Nikhil; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kuykendall, William; Kuze, Masahiro; Kuzhir, Polina; Kvasnicka, Ondrej; Kvita, Jiri; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labarga, Luis; Labbe, Julien; Lablak, Said; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramon; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Laisne, Emmanuel; Lamanna, Massimo; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Landsman, Hagar; Lane, Jenna; Lange, Clemens; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Lapin, Vladimir; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larionov, Anatoly; Larner, Aimee; Lasseur, Christian; Lassnig, Mario; Lau, Wing; Laurelli, Paolo; Lavorato, Antonia; Lavrijsen, Wim; Laycock, Paul; Lazarev, Alexandre; Lazzaro, Alfio; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Maner, Christophe; Le Menedeu, Eve; Lebedev, Alexander; Lebel, Celine; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Michel; Legendre, Marie; Leger, Annie; LeGeyt, Benjamin; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Lellouch, Jeremie; Leltchouk, Mikhail; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leontsinis, Stefanos; Leroy, Claude; Lessard, Jean-Raphael; Lesser, Jonas; Lester, Christopher; Leung Fook Cheong, Annabelle; Leveque, Jessica; Levin, Daniel; Levinson, Lorne; Levitski, Mikhail; Lewandowska, Marta; Lewis, George; Leyton, Michael; Li, Bo; Li, Haifeng; Li, Shu; Li, Xuefei; Liang, Zhihua; Liang, Zhijun; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Lifshitz, Ronen; Lilley, Joseph; Limbach, Christian; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linde, Frank; Linnemann, James; Lipeles, Elliot; Lipinsky, Lukas; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Minghui; Liu, Shengli; Liu, Yanwen; Livan, Michele; Livermore, Sarah; Lleres, Annick; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Lockwitz, Sarah; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Loken, James; Lombardo, Vincenzo Paolo; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Losada, Marta; Loscutoff, Peter; Sterzo, Francesco Lo; Losty, Michael; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lu, Liang; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dorthe; Ludwig, Inga; Ludwig, Jens; Luehring, Frederick; Luijckx, Guy; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Bjorn; Lundberg, Johan; Lundquist, Johan; Lungwitz, Matthias; Lupi, Anna; Lutz, Gerhard; Lynn, David; Lys, Jeremy; Lytken, Else; Ma, Hong; Ma, Lian Liang; Macana Goia, Jorge Andres; Maccarrone, Giovanni; Macchiolo, Anna; Macek, Bostjan; Machado Miguens, Joana; Macina, Daniela; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mattig, Peter; Mattig, Stefan; Magalhaes Martins, Paulo Jorge; Magnoni, Luca; Magradze, Erekle; Mahalalel, Yair; Mahboubi, Kambiz; Mahout, Gilles; Maiani, Camilla; Maidantchik, Carmen; Maio, Amelia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Mal, Prolay; Malecki, Pawel; Malecki, Piotr; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mameghani, Raphael; Mamuzic, Judita; Manabe, Atsushi; Mandelli, Luciano; Mandic, Igor; Mandrysch, Rocco; Maneira, Jose; Mangeard, Pierre-Simon; Manjavidze, Ioseb; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Manz, Andreas; Mapelli, Alessandro; Mapelli, Livio; March, Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marin, Alexandru; Marino, Christopher; Marroquim, Fernando; Marshall, Robin; Marshall, Zach; Martens, Kalen; Marti-Garcia, Salvador; Martin, Andrew; Martin, Brian; Martin, Brian Thomas; Martin, Franck Francois; Martin, Jean-Pierre; Martin, Philippe; Martin, Tim; Martin Dit Latour, Bertrand; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Mass, Martin; Massa, Ignazio; Massaro, Graziano; Massol, Nicolas; Mastroberardino, Anna; Masubuchi, Tatsuya; Mathes, Markus; Matricon, Pierre; Matsumoto, Hiroshi; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maugain, Jean-Marie; Maxfield, Stephen; Maximov, Dmitriy; May, Edward; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mazzanti, Marcello; Mazzoni, Enrico; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; McGlone, Helen; Mchedlidze, Gvantsa; McLaren, Robert Andrew; Mclaughlan, Tom; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehdiyev, Rashid; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meinhardt, Jens; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Mendoza Navas, Luis; Meng, Zhaoxia; Mengarelli, Alberto; Menke, Sven; Menot, Claude; Meoni, Evelin; Mercurio, Kevin Michael; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meuser, Stefan; Meyer, Carsten; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Meyer, W.Thomas; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Miele, Paola; Migas, Sylwia; Mijovic, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikulec, Bettina; Mikuz, Marko; Miller, David; Miller, Robert; Mills, Bill; Mills, Corrinne; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Minano, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Miralles Verge, Lluis; Misiejuk, Andrzej; Mitrevski, Jovan; Mitrofanov, Gennady; Mitsou, Vasiliki A.; Mitsui, Shingo; Miyagawa, Paul; Miyazaki, Kazuki; Mjornmark, Jan-Ulf; Moa, Torbjoern; Mockett, Paul; Moed, Shulamit; Moeller, Victoria; Monig, Klaus; Moser, Nicolas; Mohapatra, Soumya; Mohn, Bjarte; Mohr, Wolfgang; Mohrdieck-Mock, Susanne; Moisseev, Artemy; Moles-Valls, Regina; Molina-Perez, Jorge; Moneta, Lorenzo; Monk, James; Monnier, Emmanuel; Montesano, Simone; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Moorhead, Gareth; Mora Herrera, Clemencia; Moraes, Arthur; Morais, Antonio; Morange, Nicolas; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morii, Masahiro; Morin, Jerome; Morita, Youhei; Morley, Anthony Keith; Mornacchi, Giuseppe; Morone, Maria-Christina; Morozov, Sergey; Morris, John; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mudrinic, Mihajlo; Mueller, Felix; Mueller, James; Mueller, Klemens; Muller, Thomas; Muenstermann, Daniel; Muijs, Sandra; Muir, Alex; Munwes, Yonathan; Murakami, Koichi; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nadal, Jordi; Nagai, Koichi; Nagano, Kunihiro; Nagasaka, Yasushi; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakano, Itsuo; Nanava, Gizo; Napier, Austin; Nash, Michael; Nation, Nigel; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Neal, Homer; Nebot, Eduardo; Nechaeva, Polina; Negri, Andrea; Negri, Guido; Nektarijevic, Snezana; Nelson, Andrew; Nelson, Silke; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Nesterov, Stanislav; Neubauer, Mark; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nickerson, Richard; Nicolaidou, Rosy; Nicolas, Ludovic; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Niinikoski, Tapio; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolaev, Kirill; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nishiyama, Tomonori; Nisius, Richard; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Nomoto, Hiroshi; Nordberg, Markus; Nordkvist, Bjoern; Norton, Peter; Novakova, Jana; Nozaki, Mitsuaki; Nozicka, Miroslav; Nozka, Libor; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; Nyman, Tommi; O'Brien, Brendan Joseph; O'Neale, Steve; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Ocariz, Jose; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Ohshita, Hidetoshi; Ohska, Tokio Kenneth; Ohsugi, Takashi; Okada, Shogo; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olcese, Marco; Olchevski, Alexander; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Omachi, Chihiro; Onofre, Antonio; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Orellana, Frederik; Oren, Yona; Orestano, Domizia; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Ortega, Eduardo; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Otero y Garzon, Gustavo; Ottersbach, John; Ouchrif, Mohamed; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Owen, Mark; Owen, Simon; Oye, Ola; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Paganis, Efstathios; Paige, Frank; Pajchel, Katarina; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panes, Boris; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Panuskova, Monika; Paolone, Vittorio; Paoloni, Alessandro; Papadelis, Aras; Papadopoulou, Theodora; Paramonov, Alexander; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pasztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Pecsy, Martin; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Peng, Haiping; Pengo, Ruggero; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Cavalcanti, Tiago Perez; Perez Codina, Estel; Perez Garcia-Estan, Maria Teresa; Perez Reale, Valeria; Peric, Ivan; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Perrodo, Pascal; Persembe, Seda; Peshekhonov, Vladimir; Peters, Onne; Petersen, Brian; Petersen, Jorgen; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Alan; Phillips, Peter William; Piacquadio, Giacinto; Piccaro, Elisa; Piccinini, Maurizio; Pickford, Andrew; Piec, Sebastian Marcin; Piegaia, Ricardo; Pilcher, James; Pilkington, Andrew; Pina, Joao Antonio; Pinamonti, Michele; Pinder, Alex; Pinfold, James; Ping, Jialun; Pinto, Belmiro; Pirotte, Olivier; Pizio, Caterina; Placakyte, Ringaile; Plamondon, Mathieu; Plano, Will; Pleier, Marc-Andre; Pleskach, Anatoly; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Poghosyan, Tatevik; Pohl, Martin; Polci, Francesco; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomarede, Daniel Marc; Pomeroy, Daniel; Pommes, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Bueso, Xavier Portell; Porter, Robert; Posch, Christoph; Pospelov, Guennady; Pospisil, Stanislav; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Prabhu, Robindra; Pralavorio, Pascal; Prasad, Srivas; Pravahan, Rishiraj; Prell, Soeren; Pretzl, Klaus Peter; Pribyl, Lukas; Price, Darren; Price, Lawrence; Price, Michael John; Prichard, Paul; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qian, Jianming; Qian, Zuxuan; Qin, Zhonghua; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radescu, Voica; Radics, Balint; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rahm, David; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Ramstedt, Magnus; Randrianarivony, Koloina; Ratoff, Peter; Rauscher, Felix; Rauter, Emanuel; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reichold, Armin; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Reljic, Dusan; Rembser, Christoph; Ren, Zhongliang; Renaud, Adrien; Renkel, Peter; Rensch, Bertram; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Richards, Alexander; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rieke, Stefan; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rivoltella, Giancesare; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robinson, Mary; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Rodier, Stephane; Rodriguez, Diego; Rodriguez Garcia, Yohany; Roe, Adam; Roe, Shaun; Rohne, Ole; Rojo, Victoria; Rolli, Simona; Romaniouk, Anatoli; Romanov, Victor; Romeo, Gaston; Romero Maltrana, Diego; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rose, Matthew; Rosenbaum, Gabriel; Rosenberg, Eli; Rosendahl, Peter Lundgaard; Rosselet, Laurent; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rossi, Lucio; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Rubinskiy, Igor; Ruckert, Benjamin; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Gerald; Ruhr, Frederik; Ruggieri, Federico; Ruiz-Martinez, Aranzazu; Rulikowska-Zarebska, Elzbieta; Rumiantsev, Viktor; Rumyantsev, Leonid; Runge, Kay; Runolfsson, Ogmundur; Rurikova, Zuzana; Rusakovich, Nikolai; Rust, Dave; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Ryadovikov, Vasily; Ryan, Patrick; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Rzaeva, Sevda; Saavedra, Aldo; Sadeh, Iftach; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salihagic, Denis; Salnikov, Andrei; Salt, Jose; Salvachua Ferrando, Belen; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Bjorn Hallvard; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandhu, Pawan; Sandoval, Tanya; Sandstroem, Rikard; Sandvoss, Stephan; Sankey, Dave; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Saraiva, Joao; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sartisohn, Georg; Sasaki, Osamu; Sasaki, Takashi; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Sauvan, Jean-Baptiste; Savard, Pierre; Savinov, Vladimir; Savu, Dan Octavian; Savva, Panagiota; Sawyer, Lee; Saxon, David; Says, Louis-Pierre; Sbarra, Carla; Sbrizzi, Antonio; Scallon, Olivia; Scannicchio, Diana; Schaarschmidt, Jana; Schacht, Peter; Schafer, Uli; Schaepe, Steffen; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R. Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schlereth, James; Schmidt, Evelyn; Schmidt, Michael; Schmieden, Kristof; Schmitt, Christian; Schmitz, Martin; Schoning, Andre; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schroeder, Christian; Schroer, Nicolai; Schuh, Silvia; Schuler, Georges; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Jan; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Scott, Bill; Searcy, Jacob; Sedykh, Evgeny; Segura, Ester; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, Jose; Sekhniaidze, Givi; Seliverstov, Dmitry; Sellden, Bjoern; Sellers, Graham; Seman, Michal; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Seuster, Rolf; Severini, Horst; Sevior, Martin; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaver, Leif; Shaw, Christian; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shimizu, Shima; Shimojima, Makoto; Shin, Taeksu; Shmeleva, Alevtina; Shochet, Mel; Short, Daniel; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siebel, Anca-Mirela; Siegert, Frank; Siegrist, James; Sijacki, Djordje; Silbert, Ohad; Silva, Jose; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simmons, Brinick; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjolin, Jorgen; Sjursen, Therese; Skinnari, Louise Anastasia; Skovpen, Kirill; Skubic, Patrick; Skvorodnev, Nikolai; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Sloan, Terrence; Sloper, John erik; Smakhtin, Vladimir; Smirnov, Sergei; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snuverink, Jochem; Snyder, Scott; Soares, Mara; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Sondericker, John; Soni, Nitesh; Sopko, Vit; Sopko, Bruno; Sorbi, Massimo; Sosebee, Mark; Soukharev, Andrey; Spagnolo, Stefania; Spano, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spila, Federico; Spiriti, Eleuterio; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St. Denis, Richard Dante; Stahl, Thorsten; Stahlman, Jonathan; Stamen, Rainer; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staude, Arnold; Stavina, Pavel; Stavropoulos, Georgios; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stevenson, Kyle; Stewart, Graeme; Stillings, Jan Andre; Stockmanns, Tobias; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strang, Michael; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Strohmer, Raimund; Strom, David; Strong, John; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Stumer, Iuliu; Stupak, John; Sturm, Philipp; Soh, Dart-yin; Su, Dong; Subramania, Halasya Siva; Succurro, Antonella; Sugaya, Yorihito; Sugimoto, Takuya; Suhr, Chad; Suita, Koichi; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Sushkov, Serge; Susinno, Giancarlo; Sutton, Mark; Suzuki, Yu; Sviridov, Yuri; Swedish, Stephen; Sykora, Ivan; Sykora, Tomas; Szeless, Balazs; Sanchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taga, Adrian; Taiblum, Nimrod; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tanaka, Yoshito; Tani, Kazutoshi; Tannoury, Nancy; Tappern, Geoffrey; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Terada, Susumu; Terashi, Koji; Terron, Juan; Terwort, Mark; Testa, Marianna; Teuscher, Richard; Tevlin, Christopher; Thadome, Jocelyn; Therhaag, Jan; Theveneaux-Pelzer, Timothee; Thioye, Moustapha; Thoma, Sascha; Thomas, Juergen; Thompson, Emily; Thompson, Paul; Thompson, Peter; Thompson, Stan; Thomson, Evelyn; Thomson, Mark; Thun, Rudolf; Tic, Tomas; Tikhomirov, Vladimir; Tikhonov, Yury; Timmermans, Charles; Tipton, Paul; Viegas, Florbela De Jes Tique Aires; Tisserant, Sylvain; Tobias, Jurgen; Toczek, Barbara; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokar, Stanislav; Tokunaga, Kaoru; Tokushuku, Katsuo; Tollefson, Kirsten; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tong, Guoliang; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torro Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Traynor, Daniel; Trefzger, Thomas; Treis, Johannes; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Trinh, Thi Nguyet; Tripiana, Martin; Triplett, Nathan; Trischuk, William; Trivedi, Arjun; Trocme, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tua, Alan; Tuggle, Joseph; Turala, Michal; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Turra, Ruggero; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Tyrvainen, Harri; Tzanakos, George; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Underwood, David; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Urkovsky, Evgeny; Urrejola, Pedro; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valderanis, Chrysostomos; Valenta, Jan; Valente, Paolo; Valentinetti, Sara; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Ferrer, Juan Antonio Valls; Van der Graaf, Harry; van der Kraaij, Erik; van der Leeuw, Robin; van der Poel, Egge; van der Ster, Daniel; Van Eijk, Bob; van Eldik, Niels; Van Gemmeren, Peter; van Kesteren, Zdenko; Van Vulpen, Ivo; Vandelli, Wainer; Vandoni, Giovanna; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Varela Rodriguez, Fernando; Vari, Riccardo; Varnes, Erich; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vassilakopoulos, Vassilios; Vazeille, Francois; Vegni, Guido; Veillet, Jean-Jacques; Vellidis, Constantine; Veloso, Filipe; Veness, Raymond; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Viehhauser, Georg; Viel, Simon; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Virchaux, Marc; Viret, Sebastien; Virzi, Joseph; Vitale, Antonio; Vitells, Ofer; Viti, Michele; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vlasak, Michal; Vlasov, Nikolai; Vogel, Adrian; Vokac, Petr; Volpi, Guido; Volpi, Matteo; Volpini, Giovanni; von der Schmitt, Hans; von Loeben, Joerg; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobiev, Alexander; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vovenko, Anatoly; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Anh, Tuan Vu; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Wolfgang; Wagner, Peter; Wahlen, Helmut; Wakabayashi, Jun; Walbersloh, Jorg; Walch, Shannon; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Waller, Peter; Wang, Chiho; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Joshua C.; Wang, Rui; Wang, Song-Ming; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Watkins, Peter; Watson, Alan; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Jens; Weber, Marc; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weigell, Philipp; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wen, Mei; Wenaus, Torre; Wendler, Shanti; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Wessels, Martin; Whalen, Kathleen; Wheeler-Ellis, Sarah Jane; Whitaker, Scott; White, Andrew; White, Martin; White, Sebastian; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik, Liv Antje Mari; Wijeratne, Peter Alexander; Wildauer, Andreas; Wildt, Martin Andre; Wilhelm, Ivan; Wilkens, Henric George; Will, Jonas Zacharias; Williams, Eric; Williams, Hugh; Willis, William; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winkelmann, Stefan; Winklmeier, Frank; Wittgen, Matthias; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wooden, Gemma; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wraight, Kenneth; Wright, Catherine; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wulf, Evan; Wunstorf, Renate; Wynne, Benjamin; Xaplanteris, Leonidas; Xella, Stefania; Xie, Song; Xie, Yigang; Xu, Chao; Xu, Da; Xu, Guofa; Yabsley, Bruce; Yamada, Miho; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Yi; Yang, Yi; Yang, Zhaoyu; Yanush, Serguei; Yao, Weiming; Yao, Yushu; Yasu, Yoshiji; Ybeles Smit, Gabriel Valentijn; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Zaets, Vassilli; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zalite, Youris; Zanello, Lucia; Zarzhitsky, Pavel; Zaytsev, Alexander; Zeitnitz, Christian; Zeller, Michael; Zema, Pasquale Federico; Zemla, Andrzej; Zendler, Carolin; Zenin, Anton; Zenin, Oleg; Zenis, Tibor; Zenonos, Zenonas; Zenz, Seth; Zerwas, Dirk; Zevi Della Porta, Giovanni; Zhan, Zhichao; Zhang, Dongliang; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zheng, Shuchen; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zieminska, Daria; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Zitoun, Robert; Zivkovic, Lidija; Zmouchko, Viatcheslav; Zobernig, Georg; Zoccoli, Antonio; Zolnierowski, Yves; Zsenei, Andras; zur Nedden, Martin; Zutshi, Vishnu; Zwalinski, Lukasz

    2013-07-16

    This article presents a search for high mass e e or mu mu resonances in pp collisions at $\\sqrt{s}$ = 7 TeV at the LHC. The data were recorded by the ATLAS experiment during 2010 and correspond to a total integrated luminosity of ~40/pb. No statistically significant excess above the Standard Model expectation is observed in the search region of dilepton invariant mass above 110 GeV. Upper limits at the 95% confidence level are set on the cross section times branching ratio of Z' resonances decaying to dielectrons and dimuons as a function of the resonance mass. A lower mass limit of 1.048 TeV on the Sequential Standard Model Z' boson is derived, as well as mass limits on Z* and E(6)-motivated Z' models.

  7. Search for high mass dilepton resonances in pp collisions at √(s)=7 TeV with the ATLAS experiment

    International Nuclear Information System (INIS)

    Aad, G.; Abbott, B.; Abdallah, J.; Abdelalim, A.A.; Abdesselam, A.; Abdinov, O.; Abi, B.; Abolins, M.; Abramowicz, H.; Abreu, H.; Acerbi, E.; Acharya, B.S.; Adams, D.L.; Addy, T.N.; Adelman, J.; Aderholz, M.; Adomeit, S.; Adragna, P.; Adye, T.; Aefsky, S.

    2011-01-01

    This Letter presents a search for high mass e + e - or μ + μ - resonances in pp collisions at √(s)=7 TeV at the LHC. The data were recorded by the ATLAS experiment during 2010 and correspond to a total integrated luminosity of ∼40 pb -1 . No statistically significant excess above the Standard Model expectation is observed in the search region of dilepton invariant mass above 110 GeV. Upper limits at the 95% confidence level are set on the cross section times branching ratio of Z ' resonances decaying to dielectrons and dimuons as a function of the resonance mass. A lower mass limit of 1.048 TeV on the Sequential Standard Model Z ' boson is derived, as well as mass limits on Z * and E 6 -motivated Z ' models.

  8. Search for high mass dilepton resonances in pp collisions at {radical}(s)=7 TeV with the ATLAS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aad, G [Fakultaet fuer Mathematik und Physik, Albert-Ludwigs-Universitaet, Freiburg i.Br. (Germany); Abbott, B [Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, Norman, OK (United States); Abdallah, J [Institut de Fisica d' Altes Energies and Universitat Autonoma de Barcelona and ICREA, Barcelona (Spain); Abdelalim, A A [Section de Physique, Universite de Geneve, Geneva (Switzerland); Abdesselam, A [Department of Physics, Oxford University, Oxford (United Kingdom); Abdinov, O [Institute of Physics, Azerbaijan Academy of Sciences, Baku (Azerbaijan); Abi, B [Department of Physics, Oklahoma State University, Stillwater, OK (United States); Abolins, M [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); Abramowicz, H [Raymond and Beverly Sackler School of Physics and Astronomy, Tel Aviv University, Tel Aviv (Israel); Abreu, H [LAL, Univ. Paris-Sud and CNRS/IN2P3, Orsay (France); Acerbi, E [INFN Sezione di Milano (Italy); Dipartimento di Fisica, Universita di Milano, Milano (Italy); Acharya, B S [INFN Gruppo Collegato di Udine (Italy); ICTP, Trieste [Italy; Adams, D L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Addy, T N [Department of Physics, Hampton University, Hampton, VA (United States); Adelman, J [Department of Physics, Yale University, New Haven, CT (United States); Aderholz, M [Max-Planck-Institut fuer Physik (Werner-Heisenberg-Institut), Muenchen (Germany); Adomeit, S [Fakultaet fuer Physik, Ludwig-Maximilians-Universitaet Muenchen, Muenchen (Germany); Adragna, P [Department of Physics, Queen Mary University of London, London (United Kingdom); Adye, T [Particle Physics Department, Rutherford Appleton Laboratory, Didcot (United Kingdom); Aefsky, S [Department of Physics, Brandeis University, Waltham, MA (United States)

    2011-06-13

    This Letter presents a search for high mass e{sup +}e{sup -} or {mu}{sup +}{mu}{sup -} resonances in pp collisions at {radical}(s)=7 TeV at the LHC. The data were recorded by the ATLAS experiment during 2010 and correspond to a total integrated luminosity of {approx}40 pb{sup -1}. No statistically significant excess above the Standard Model expectation is observed in the search region of dilepton invariant mass above 110 GeV. Upper limits at the 95% confidence level are set on the cross section times branching ratio of Z{sup '} resonances decaying to dielectrons and dimuons as a function of the resonance mass. A lower mass limit of 1.048 TeV on the Sequential Standard Model Z{sup '} boson is derived, as well as mass limits on Z{sup *} and E{sub 6}-motivated Z{sup '} models.

  9. Electromagnetic resonance waves

    International Nuclear Information System (INIS)

    Villaba, J.M.; Manjon, F.J.; Guirao, A.; Andres, M.V.

    1994-01-01

    We describe in this paper a set of experiments designed to make qualitative and quantitative measurements on electromagnetic resonances of several simple systems. The experiments are designed for the undergraduate laboratory of Electricity and Magnetism in Physics. These experiments can help the students understanding the concept of resonance, which appears in different fields of Physics. (Author) 8 refs

  10. Study of plasma start-up initiated by second harmonic electron cyclotron resonance heating on WEGA experiment

    International Nuclear Information System (INIS)

    Preynas, M.; Laqua, H. P.; Otte, M.; Stange, T.; Aßmus, D.; Wauters, T.

    2014-01-01

    Although both 1st harmonic ordinary mode (O1) and 2nd harmonic extra-ordinary mode (X2) have been successfully used to initiate pre-ionization and breakdown in many devices, a complete theoretical model is still missing to explain the success of this method. Moreover, some experimental observations are not completely understood, such as what occurs during the delay time between the turn-on of ECRH power and first signals of density or light measurements. Since during this free period the ECRH power has to be absorbed by in-vessel components, it is of prime importance to know what governs this delay time. Recently, dedicated start-up experiments have been performed on WEGA, using a 28 GHz ECRH system in X2-mode. This machine has the interesting capability to be run also as a tokamak allowing comparative experiments between stellarator (ι/2π > 0) and tokamak (ι/2π = 0) configurations. Different scans in heating power, neutral gas pressure, and rotational transform (ι) show clearly that the start-up is a two step process. A first step following the turn-on of the ECRH power during which no measurable electron density (or just above the noise level in some cases), ECE and radiated power is detected. Its duration depends strongly on the level of injected power. The second step corresponds to the gas ionization and plasma expansion phase, with a velocity of density build-up and filling-up of the vessel volume depending mainly on pressure, gas and rotational transform. Moreover, an interesting scenario of ECRH pre-ionization without loop voltage in tokamak configuration by applying a small optimal vertical field is relevant for start-up assistance on future experiments like ITER. The results from this experimental parametric study are useful for the modeling of the start-up assisted by the second harmonic electron cyclotron resonance heating. The aim of this work is to establish predictive scenarios for both ITER and W7-X operation

  11. Study of plasma start-up initiated by second harmonic electron cyclotron resonance heating on WEGA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Preynas, M.; Laqua, H. P.; Otte, M.; Stange, T.; Aßmus, D. [Max Planck Institut für Plasmaphysik, EURATOM Association, D-17491 Greifswald (Germany); Wauters, T. [Association Euratom-Belgian State, LPP-ERM/KMS, 1000 Brussels (Belgium)

    2014-02-12

    Although both 1st harmonic ordinary mode (O1) and 2nd harmonic extra-ordinary mode (X2) have been successfully used to initiate pre-ionization and breakdown in many devices, a complete theoretical model is still missing to explain the success of this method. Moreover, some experimental observations are not completely understood, such as what occurs during the delay time between the turn-on of ECRH power and first signals of density or light measurements. Since during this free period the ECRH power has to be absorbed by in-vessel components, it is of prime importance to know what governs this delay time. Recently, dedicated start-up experiments have been performed on WEGA, using a 28 GHz ECRH system in X2-mode. This machine has the interesting capability to be run also as a tokamak allowing comparative experiments between stellarator (ι/2π > 0) and tokamak (ι/2π = 0) configurations. Different scans in heating power, neutral gas pressure, and rotational transform (ι) show clearly that the start-up is a two step process. A first step following the turn-on of the ECRH power during which no measurable electron density (or just above the noise level in some cases), ECE and radiated power is detected. Its duration depends strongly on the level of injected power. The second step corresponds to the gas ionization and plasma expansion phase, with a velocity of density build-up and filling-up of the vessel volume depending mainly on pressure, gas and rotational transform. Moreover, an interesting scenario of ECRH pre-ionization without loop voltage in tokamak configuration by applying a small optimal vertical field is relevant for start-up assistance on future experiments like ITER. The results from this experimental parametric study are useful for the modeling of the start-up assisted by the second harmonic electron cyclotron resonance heating. The aim of this work is to establish predictive scenarios for both ITER and W7-X operation.

  12. Five and four dimensional experiments for robust backbone resonance assignment of large intrinsically disordered proteins: application to Tau3x protein

    International Nuclear Information System (INIS)

    Żerko, Szymon; Byrski, Piotr; Włodarczyk-Pruszyński, Paweł; Górka, Michał; Ledolter, Karin; Masliah, Eliezer; Konrat, Robert; Koźmiński, Wiktor

    2016-01-01

    New experiments dedicated for large IDPs backbone resonance assignment are presented. The most distinctive feature of all described techniques is the employment of MOCCA-XY16 mixing sequences to obtain effective magnetization transfers between carbonyl carbon backbone nuclei. The proposed 4 and 5 dimensional experiments provide a high dispersion of obtained signals making them suitable for use in the case of large IDPs (application to 354 a. a. residues of Tau protein 3x isoform is presented) as well as provide both forward and backward connectivities. What is more, connecting short chains interrupted with proline residues is also possible. All the experiments employ non-uniform sampling.

  13. Five and four dimensional experiments for robust backbone resonance assignment of large intrinsically disordered proteins: application to Tau3x protein

    Energy Technology Data Exchange (ETDEWEB)

    Żerko, Szymon; Byrski, Piotr; Włodarczyk-Pruszyński, Paweł; Górka, Michał [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre (Poland); Ledolter, Karin [University of Vienna, Department of Computational and Structural Biology, Max F. Perutz Laboratories (Austria); Masliah, Eliezer [University of California, San Diego, Departments of Neuroscience and Pathology (United States); Konrat, Robert [University of Vienna, Department of Computational and Structural Biology, Max F. Perutz Laboratories (Austria); Koźmiński, Wiktor, E-mail: kozmin@chem.uw.edu.pl [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre (Poland)

    2016-08-15

    New experiments dedicated for large IDPs backbone resonance assignment are presented. The most distinctive feature of all described techniques is the employment of MOCCA-XY16 mixing sequences to obtain effective magnetization transfers between carbonyl carbon backbone nuclei. The proposed 4 and 5 dimensional experiments provide a high dispersion of obtained signals making them suitable for use in the case of large IDPs (application to 354 a. a. residues of Tau protein 3x isoform is presented) as well as provide both forward and backward connectivities. What is more, connecting short chains interrupted with proline residues is also possible. All the experiments employ non-uniform sampling.

  14. Numerical analysis of resonances induced by s wave neutrons in transmission time-of-flight experiments with a computer IBM 7094 II; Methodes d'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol et automatisation de ces methodes sur ordinateur IBM 7094 II

    Energy Technology Data Exchange (ETDEWEB)

    Corge, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-01-01

    Numerical analysis of transmission resonances induced by s wave neutrons in time-of-flight experiments can be achieved in a fairly automatic way on an IBM 7094/II computer. The involved computations are carried out following a four step scheme: 1 - experimental raw data are processed to obtain the resonant transmissions, 2 - values of experimental quantities for each resonance are derived from the above transmissions, 3 - resonance parameters are determined using a least square method to solve the over determined system obtained by equalling theoretical functions to the correspondent experimental values. Four analysis methods are gathered in the same code, 4 - graphical control of the results is performed. (author) [French] L'automatisation, sur ordinateur IBM 7094/II, de l'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol a ete accomplie en la decomposant selon un schema articule en quatre phases: 1 - le traitement des donnees experimentales brutes pour obtenir les transmissions interfero-resonnantes, 2 - la determination des grandeurs d'analyse a partir des transmissions precedentes, 3 - l'analyse proprement dite des resonances dont les parametres sont obtenus par la resolution d'un systeme surabondant. Quatre methodes d'analyse sont groupees en un meme programme, 4 - la procedure de verification graphique. (auteur)

  15. Numerical analysis of resonances induced by s wave neutrons in transmission time-of-flight experiments with a computer IBM 7094 II; Methodes d'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol et automatisation de ces methodes sur ordinateur IBM 7094 II

    Energy Technology Data Exchange (ETDEWEB)

    Corge, Ch. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-01-01

    Numerical analysis of transmission resonances induced by s wave neutrons in time-of-flight experiments can be achieved in a fairly automatic way on an IBM 7094/II computer. The involved computations are carried out following a four step scheme: 1 - experimental raw data are processed to obtain the resonant transmissions, 2 - values of experimental quantities for each resonance are derived from the above transmissions, 3 - resonance parameters are determined using a least square method to solve the over determined system obtained by equalling theoretical functions to the correspondent experimental values. Four analysis methods are gathered in the same code, 4 - graphical control of the results is performed. (author) [French] L'automatisation, sur ordinateur IBM 7094/II, de l'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol a ete accomplie en la decomposant selon un schema articule en quatre phases: 1 - le traitement des donnees experimentales brutes pour obtenir les transmissions interfero-resonnantes, 2 - la determination des grandeurs d'analyse a partir des transmissions precedentes, 3 - l'analyse proprement dite des resonances dont les parametres sont obtenus par la resolution d'un systeme surabondant. Quatre methodes d'analyse sont groupees en un meme programme, 4 - la procedure de verification graphique. (auteur)

  16. Triple photonic band-gap structure dynamically induced in the presence of spontaneously generated coherence

    International Nuclear Information System (INIS)

    Gao Jinwei; Bao Qianqian; Wan Rengang; Cui Cuili; Wu Jinhui

    2011-01-01

    We study a cold atomic sample coherently driven into the five-level triple-Λ configuration for attaining a dynamically controlled triple photonic band-gap structure. Our numerical calculations show that three photonic band gaps with homogeneous reflectivities up to 92% can be induced on demand around the probe resonance by a standing-wave driving field in the presence of spontaneously generated coherence. All these photonic band gaps are severely malformed with probe reflectivities declining rapidly to very low values when spontaneously generated coherence is gradually weakened. The triple photonic band-gap structure can also be attained in a five-level chain-Λ system of cold atoms in the absence of spontaneously generated coherence, which however requires two additional traveling-wave fields to couple relevant levels.

  17. Sequence determination and resonance assignments of an Azomonas siderophore using 13C natural abundance 13C-1H HNCA experiment

    Czech Academy of Sciences Publication Activity Database

    Wasielewski, E.; Abdallah, M. A.; Kyslík, Pavel; Kieffer, B.

    2001-01-01

    Roč. 4, - (2001), s. 765-770 ISSN 1387-1609 Institutional research plan: CEZ:AV0Z5020903 Keywords : determination * resonance * assignments Subject RIV: EE - Microbiology, Virology Impact factor: 0.555, year: 2001

  18. Assembly of Liposomes Controlled by Triple Helix Formation

    DEFF Research Database (Denmark)

    Vogel, Stefan; Jakobsen, Ulla

    2013-01-01

    Attachment of DNA to the surface of different solid nanoparticles (e.g. gold- and silica nanoparticles) is well established and a number of DNA-modified solid nanoparticle systems have been applied to thermal denaturation analysis of oligonucleotides. We report herein the non-covalent immobilizat...... analysis (NTA) and dynamic light scattering (DLS) show independently from ultraviolet spectroscopy experiments the formation of liposome aggregates.......-covalent immobilization of oligonucleotides on the surface of soft nanoparticles (e.g. liposomes) and the subsequent controlled assembly by DNA triple helix formation. The non-covalent approach avoids tedious surface chemistry and necessary purification procedures and can simplify and extend the available methodology...... sequences (G or C-rich) to explore the applicability of the method for different triple helical assembly modes. We demonstrate advantages and limitations of the approach and proof the reversible and reproducible formation of liposome aggregates during thermal denaturation cycles. Nanoparticle tracking...

  19. Analysis methods of neutrons induced resonances in the transmission experiments by time-of-flight and automation of these methods on IBM 7094 II computer

    International Nuclear Information System (INIS)

    Corge, C.

    1967-01-01

    The neutron induced resonances analysis aims to determine the neutrons characteristics, leading to the excitation energies, de-excitation probabilities by gamma radiation emission, by neutron emission or by fission, their spin, their parity... This document describes the methods developed, or adapted, the calculation schemes and the algorithms implemented to realize such analysis on a computer, from data obtained during time-of-flight experiments on the linear accelerator of Saclay. (A.L.B.)

  20. Trial fabrication of a secondary x-ray spectrometer with high energy resolution for use in x-ray resonant inelastic scattering experiments

    International Nuclear Information System (INIS)

    Iwazumi, Toshiaki

    2004-01-01

    An instrument was fabricated for use of x-ray resonant inelastic scattering with high-energy resolution in expectation of finding new physical phenomena in strongly correlated electron systems. In the scattering x-ray spectrometer, an asymmetric Johanson crystal spectrometer, which was deployed in an asymmetric Rowland configuration, was designed, fabricated and assessed. The performance expected theoretically for the Johanson spectrometer was recognized from experiments by use of synchrotron radiation. (Y. Kazumata)

  1. Searches for heavy resonances in all-jet final states with top quarks using jet substructure techniques with the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Usai, Emanuele

    2017-12-15

    While the Standard Model is very successful in describing subnuclear phenomena, it is not a complete theory of particle physics. Several new theories have been developed to address its issues. Many extensions of the Standard Model predict the existence of high-mass resonances. In some cases these resonances have an enhanced coupling to third generation quarks or to a hypothetical new generation of heavy non-chiral quarks. This thesis describes two searches for new phenomena compatible with these theories, in particular a search is presented for resonant top-antitop production, and the first search for heavy resonances decaying to a top quark and a heavy top quark partner T is shown. The searches target the all-jets decay channels and use data collected by the CMS Experiment at the CERN LHC between 2012 and 2015 at a center-of-mass energy of 8 TeV and 13 TeV. Due to the high mass of the resonances considered, the final state particles have a high Lorentz-boost. To reconstruct the hadronic decay of the top quarks and W bosons, jet substructure techniques such as top quark and W boson tagging algorithms, and boosted b jet identification are employed. These algorithms are studied with a particular focus on their validation and performance assessment. No signs of physics beyond the Standard Model are observed, but stringent limits are placed on the production of heavy resonances decaying to top-antitop quark pairs or a top quark and a heavy T quark.

  2. Searches for heavy resonances in all-jet final states with top quarks using jet substructure techniques with the CMS experiment

    International Nuclear Information System (INIS)

    Usai, Emanuele

    2017-12-01

    While the Standard Model is very successful in describing subnuclear phenomena, it is not a complete theory of particle physics. Several new theories have been developed to address its issues. Many extensions of the Standard Model predict the existence of high-mass resonances. In some cases these resonances have an enhanced coupling to third generation quarks or to a hypothetical new generation of heavy non-chiral quarks. This thesis describes two searches for new phenomena compatible with these theories, in particular a search is presented for resonant top-antitop production, and the first search for heavy resonances decaying to a top quark and a heavy top quark partner T is shown. The searches target the all-jets decay channels and use data collected by the CMS Experiment at the CERN LHC between 2012 and 2015 at a center-of-mass energy of 8 TeV and 13 TeV. Due to the high mass of the resonances considered, the final state particles have a high Lorentz-boost. To reconstruct the hadronic decay of the top quarks and W bosons, jet substructure techniques such as top quark and W boson tagging algorithms, and boosted b jet identification are employed. These algorithms are studied with a particular focus on their validation and performance assessment. No signs of physics beyond the Standard Model are observed, but stringent limits are placed on the production of heavy resonances decaying to top-antitop quark pairs or a top quark and a heavy T quark.

  3. Determination of the solid-liquid-vapor triple point pressure of carbon

    International Nuclear Information System (INIS)

    Haaland, D.M.

    1976-01-01

    A detailed experimental study of the triple point pressure of carbon using laser heating techniques has been completed. Uncertainties and conflict in previous investigations have been addressed and substantial data presented which places the solid-liquid-vapor carbon triple point at 107 +- 2 atmospheres. This is in agreement with most investigations which have located the triple point pressure between 100 and 120 atmospheres, but is in disagreement with recent low pressure carbon experiments. The absence of any significant polymorphs of carbon other than graphite suggests that the graphite-liquid-vapor triple point has been measured. Graphite samples were melted in a pressure vessel using a 400 W Nd:YAG continuous-wave laser focused to a maximum power density of approximately 80 kW/cm 2 . Melt was confirmed by detailed microstructure analysis and x-ray diffraction of the recrystallized graphite. Experiments to determine the minimum melt pressure of carbon were completed as a function of sample size, type of inert gas, and laser power density to asure that laser power densities were sufficient to produce melt at the triple point pressure of carbon, and the pressure of carbon at the surface of the sample was identical to the measured pressure of the inert gas in the pressure vessel. High-speed color cinematography of the carbon heating revealed the presence of a laser-generated vapor or particle plume in front of the sample. The existence of this bright plume pevented the measurement of the carbon triple point temperature

  4. Properties of Hot and Fast Rotating Atomic Nuclei Studied by Means of Giant Dipole Resonance in Exclusive Experiments

    International Nuclear Information System (INIS)

    Maj, A.

    2000-01-01

    This work entitled ''Properties of hot and fast rotating atomic nuclei studied by means of Giant Dipole Resonance in exclusive experiments'', is the habilitation thesis of dr. Adam Maj. It consists of the review (in Polish) of performed research and of attached reprints from 16 original publications (in English) which A. Maj is the main or one of the main authors. All the studies were performed in collaboration with the groups from Milano and Copenhagen, using the HECTOR array equipment (described in chapter V). The Giant Dipole Resonance couples to the quadrupole degrees of freedom of the nucleus, and therefore constitutes a unique probe to test the shapes of atomic nuclei. In addition, the γ decay of the GDR from highly excited nuclei is a very fast process, it can compete with other modes of nuclear decay, and therefore can provide the information on the initial stages of excited nuclei. The presented investigations were concentrated on the following aspects: the shapes and thermal shape fluctuations, the origin of the behaviour of the GDR width, the properties of some exotic nuclei (Jacobi shapes, superdeformation, superheavy nuclei) and on ''entrance channel'' effects. The GDR γ decay was measured for nuclei with very different masses: from light nuclei with A≅45, through A≅110, 145,170,190, up to superheavy nuclei with A≅270. The shapes of hot nuclei are not fixed but fluctuate. The extent of these fluctuations and their influence on the measured quantities (GDR strength function, angular distribution and effective shape) is discussed in chapter VI.1. The observed width of the GDR is found to arise from the interplay of two effects: the thermal shape fluctuations, which are controlled by the nuclear temperature, and the deformation effects, controlled by the angular momentum. The ''collisional damping'' effect, which should influence the intrinsic GDR width, was found to be negligible (chapter VI.2). The GDR γ decay from hot superheavy nucleus 272 Hs

  5. Safety of cardiac magnetic resonance and contrast angiography for neonates and small infants: a 10-year single-institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Rangamani, Sheela; Li, Ling; Harvey, Lisa; Fletcher, Scott E.; Danford, David A.; Kutty, Shelby [University of Nebraska College of Medicine/Creighton University School of Medicine, Joint Division of Pediatric Cardiology, Omaha, NE (United States); Varghese, Joby [Children' s Hospital and Medical Center, Division of Pediatric Cardiac Anesthesia, Omaha, NE (United States); Hammel, James M.; Duncan, Kim F. [Children' s Hospital and Medical Center, Division of Cardiothoracic Surgery, Omaha, NE (United States)

    2012-11-15

    With increasing applications of cardiac magnetic resonance (CMR) and magnetic resonance angiography (MRA) for evaluation of congenital heart disease (CHD), safety of this technology in the very young is of particular interest. We report our 10-year experience with CMR in neonates and small infants with particular focus on the safety profile and incidence of adverse events (AEs). We reviewed clinical, anesthesia and nursing records of all children {<=}120 days of age who underwent CMR. We recorded variables including cardiac diagnosis, study duration, anesthesia type and agents, prostaglandin E1 (PGE1) dependence and gadolinium (Gd) use. Serially recorded temperature, systemic saturation (SpO{sub 2}) and cardiac rhythm were analyzed. Primary outcome measure was any AE during or <24 h after the procedure, including minor AEs such as hypothermia (axillary temperature {<=}95 F), desaturation (SpO{sub 2} drop {>=}10% below baseline) and bradycardia (heart rate {<=}100 bpm). Secondary outcome measure was unplanned overnight hospitalization of outpatients. Children (n = 143; 74 boys, 69 girls) had a median age of 6 days (1-117), and 98 were {<=}30 days at the time of CMR. The median weight was 3.4 kg (1.4-6 kg) and body surface area 0.22 m{sup 2} (0.13-0.32 m{sup 2}). There were 118 (83%) inpatients (108 receiving intensive care) and 25 (17%) outpatients. Indications for CMR were assessment of aortic arch (n = 57), complex CHD (n = 41), pulmonary veins (n = 15), vascular ring (n = 8), intracardiac mass (n = 8), pulmonary artery (n = 7), ventricular volume (n = 4), and systemic veins (n = 3). CMR was performed using a 1.5-T scanner and a commercially available coil. CMR utilized general anesthesia (GA) in 86 children, deep sedation (DS) in 50 and comforting methods in seven. MRA was performed in 136 children. Fifty-nine children were PGE1-dependent and 39 had single-ventricle circulation. Among children on PGE1, 43 (73%) had GA and 10 (17%) had DS. Twelve children (9%) had

  6. Safety of cardiac magnetic resonance and contrast angiography for neonates and small infants: a 10-year single-institution experience

    International Nuclear Information System (INIS)

    Rangamani, Sheela; Li, Ling; Harvey, Lisa; Fletcher, Scott E.; Danford, David A.; Kutty, Shelby; Varghese, Joby; Hammel, James M.; Duncan, Kim F.

    2012-01-01

    With increasing applications of cardiac magnetic resonance (CMR) and magnetic resonance angiography (MRA) for evaluation of congenital heart disease (CHD), safety of this technology in the very young is of particular interest. We report our 10-year experience with CMR in neonates and small infants with particular focus on the safety profile and incidence of adverse events (AEs). We reviewed clinical, anesthesia and nursing records of all children ≤120 days of age who underwent CMR. We recorded variables including cardiac diagnosis, study duration, anesthesia type and agents, prostaglandin E1 (PGE1) dependence and gadolinium (Gd) use. Serially recorded temperature, systemic saturation (SpO 2 ) and cardiac rhythm were analyzed. Primary outcome measure was any AE during or 2 drop ≥10% below baseline) and bradycardia (heart rate ≤100 bpm). Secondary outcome measure was unplanned overnight hospitalization of outpatients. Children (n = 143; 74 boys, 69 girls) had a median age of 6 days (1-117), and 98 were ≤30 days at the time of CMR. The median weight was 3.4 kg (1.4-6 kg) and body surface area 0.22 m 2 (0.13-0.32 m 2 ). There were 118 (83%) inpatients (108 receiving intensive care) and 25 (17%) outpatients. Indications for CMR were assessment of aortic arch (n = 57), complex CHD (n = 41), pulmonary veins (n = 15), vascular ring (n = 8), intracardiac mass (n = 8), pulmonary artery (n = 7), ventricular volume (n = 4), and systemic veins (n = 3). CMR was performed using a 1.5-T scanner and a commercially available coil. CMR utilized general anesthesia (GA) in 86 children, deep sedation (DS) in 50 and comforting methods in seven. MRA was performed in 136 children. Fifty-nine children were PGE1-dependent and 39 had single-ventricle circulation. Among children on PGE1, 43 (73%) had GA and 10 (17%) had DS. Twelve children (9%) had adverse events (AEs) - one major and 11 minor. Of those 12, nine children had GA (10%) and three had DS (6%). The single major AE was

  7. Changes in brain magnetic resonance imaging patterns for preterm infants after introduction of a magnetic resonance-compatible incubator coil system: 5-year experience at a single institution.

    Science.gov (United States)

    Cho, Hyun-Hae; Kim, In-One; Cheon, Jung-Eun; Choi, Young Hun; Lee, So Mi; Kim, Woo Sun

    2016-09-01

    To evaluate the changes in using patterns of brain magnetic resonance imaging (MRI) in preterm infants after introduction of a MR-compatible incubator coil system. Brain MRIs for preterm infants with the MR-compatible incubator coil from March 2010 to July 2014 (n=154, group A) were compared with MRIs prior to the introduction of the incubator coil, from March 2005 to February 2010 (n=65, group B). Clinical data, MRI findings, acquisition time, and incidence of adverse events during the study were retrospectively reviewed. For the qualitative analysis of the examinations, the presence of motion artefact, spatial resolution, and overall image quality were assessed. Signal uniformity of each sequence was evaluated for a quantitative comparison. Comparing with group B, Group A was significantly younger (36+3 vs. 38+3 weeks, pimage acquisition time was significantly shorter in group A (21.4±4.5 vs. 25.4±5.5min, pimage quality with decreased signal variation than group B (all pimage quality. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. An ultrahigh-vacuum apparatus for resonant diffraction experiments using soft x rays (hν=300-2000 eV)

    International Nuclear Information System (INIS)

    Takeuchi, T.; Chainani, A.; Takata, Y.; Tanaka, Y.; Oura, M.; Tsubota, M.; Senba, Y.; Ohashi, H.; Mochiku, T.; Hirata, K.; Shin, S.

    2009-01-01

    We have developed an ultrahigh-vacuum instrument for resonant diffraction experiments using polarized soft x rays in the energy range of hν=300-2000 eV at beamline BL17SU of SPring-8. The diffractometer consists of modified differentially pumped rotary feedthroughs for θ-2θ stages, a sample manipulator with motor-controlled x-y-z-, tilt (χ)-, and azimuth (φ)-axes, and a liquid helium flow-type cryostat for temperature dependent measurements between 30 and 300 K. Test results indicate that the diffractometer exhibits high reproducibility (better than 0.001 deg.) for a Bragg reflection of α-quartz 100 at a photon energy of hν=1950 eV. Typical off- and on-resonance Bragg reflections in the energy range of 530-1950 eV could be measured using the apparatus. The results show that x-ray diffraction experiments with energy-, azimuth-, and incident photon polarization-dependence can be reliably measured using soft x rays in the energy range of ∼300-2000 eV. The facility can be used for resonant diffraction experiments across the L-edge of transition metals, M-edge of lanthanides, and up to the Si K-edge of materials.

  9. Role of intertube interactions in double- and triple-walled carbon nanotubes.

    Science.gov (United States)

    Hirschmann, Thomas Ch; Araujo, Paulo T; Muramatsu, Hiroyuki; Rodriguez-Nieva, Joaquin F; Seifert, Max; Nielsch, Kornelius; Kim, Yoong Ahm; Dresselhaus, Mildred S

    2014-02-25

    Resonant Raman spectroscopy studies are performed to access information about the intertube interactions and wall-to-wall distances in double- and triple-walled carbon nanotubes. Here, we explain how the surroundings of the nanotubes in a multiwalled system influence their radial breathing modes. Of particular interest, the innermost tubes in double- and triple-walled carbon nanotube systems are shown to be significantly shielded from environmental interactions, except for those coming from the intertube interaction with their own respective host tubes. From a comparison of the Raman results for bundled as well as individual fullerene-peapod-derived double- and triple-walled carbon nanotubes, we observe that metallic innermost tubes, when compared to their semiconducting counterparts, clearly show weaker intertube interactions. Additionally, we discuss a correlation between the wall-to-wall distances and the frequency upshifts of the radial breathing modes observed for the innermost tubes in individual double- and triple-walled carbon nanotubes. All results allow us to contemplate fundamental properties related to DWNTs and TWNTs, as for example diameter- and chirality-dependent intertube interactions. We also discuss differences in fullerene-peapod-derived and chemical vapor deposition grown double- and triple-walled systems with the focus on mechanical coupling and interference effects.

  10. Resonator Sensitivity Optimization in Magnetic Resonance and the Development of a Magic Angle Spinning Probe for the NMR Study of Rare Spin Nuclei on Catalytic Surfaces.

    Science.gov (United States)

    Doty, Francis David

    The sensitivity of an arbitrary resonator for the detection of a magnetic resonance signal is derived from basic energy considerations, and is shown to be dependent on V(,s)/t(,90)P(' 1/2). The radiation damping time constant is shown to be inversely dependent on the rf filling factor. Several resonators are analyzed in detail. The optimum solenoid is shown to have a length of about 1.5 times the diameter. The multilayer solenoid and the capacitively shortened slotted line resonator are shown to have advantages for samples with high dielectric losses. The capacitively shortened slotted line resonator is shown to substantially reduce acoustic ringing problems. Efficient methods are discussed for double and triple tuning these resonators. A slotted cylindrical resonator is described which gives higher sensitivity and faster response time than conventional cavities for very small samples at X-band ESR frequencies. Double tuned circuits using lumped elements are shown to be generally more efficient than those using transmission lines in generating rf fields. The optimum inductance ratio of the two coils in a ('13)C, ('1)H CP experiment is about 3. The high speed cylindrical sample spinner is analyzed in terms of compressible fluid dynamics, resonant modes, and structural analysis to arrive at optimum air bearing and spinner design recommendations. The optimum radial clearance is shown to depend on the 1/3 power of the rotor diameter. The required air bearing hole diameter has a square root dependence on the rotor diameter. Air pockets are shown to increase the resonant frequencies. Relevant data for a number of high strength insulators including hard ceramics are tabulated, and limiting speeds are calculated. CP MAS experiments on a 5% monolayer of n-butylamine absorbed on (gamma)-alumina reveal six lines. By comparison with the liquid phase spectrum it was determined that at least two types of chemically different surface species were present and that surface

  11. Theoretical investigation of compounds with triple bonds

    International Nuclear Information System (INIS)

    Devarajan, Deepa

    2011-01-01

    In this thesis, compounds with potential triple-bonding character involving the heavier main-group elements, Group 4 transition metals, and the actinides uranium and thorium were studied by using molecular quantum mechanics. The triple bonds are described in terms of the individual orbital contributions (σ, π parallel , and π perpendicular to ), involving electron-sharing covalent or donor-acceptor interactions between the orbitals of two atoms or fragments. Energy decomposition, natural bond orbital, and atoms in molecules analyses were used for the bonding analysis of the triple bonds. The results of this thesis suggest that the triple-bonding character between the heavier elements of the periodic table is important and worth further study and exploration.

  12. The time domain triple probe method

    International Nuclear Information System (INIS)

    Meier, M.A.; Hallock, G.A.; Tsui, H.Y.W.; Bengtson, R.D.

    1994-01-01

    A new Langmuir probe technique based on the triple probe method is being developed to provide simultaneous measurement of plasma temperature, potential, and density with the temporal and spatial resolution required to accurately characterize plasma turbulence. When the conventional triple probe method is used in an inhomogeneous plasma, local differences in the plasma measured at each probe introduce significant error in the estimation of turbulence parameters. The Time Domain Triple Probe method (TDTP) uses high speed switching of Langmuir probe potential, rather than spatially separated probes, to gather the triple probe information thus avoiding these errors. Analysis indicates that plasma response times and recent electronics technology meet the requirements to implement the TDTP method. Data reduction techniques of TDTP data are to include linear and higher order correlation analysis to estimate fluctuation induced particle and thermal transport, as well as energy relationships between temperature, density, and potential fluctuations

  13. Triple echo steady-state (TESS) relaxometry.

    Science.gov (United States)

    Heule, Rahel; Ganter, Carl; Bieri, Oliver

    2014-01-01

    Rapid imaging techniques have attracted increased interest for relaxometry, but none are perfect: they are prone to static (B0 ) and transmit (B1 ) field heterogeneities, and commonly biased by T2 /T1 . The purpose of this study is the development of a rapid T1 and T2 relaxometry method that is completely (T2 ) or partly (T1 ) bias-free. A new method is introduced to simultaneously quantify T1 and T2 within one single scan based on a triple echo steady-state (TESS) approach in combination with an iterative golden section search. TESS relaxometry is optimized and evaluated from simulations, in vitro studies, and in vivo experiments. It is found that relaxometry with TESS is not biased by T2 /T1 , insensitive to B0 heterogeneities, and, surprisingly, that TESS-T2 is not affected by B1 field errors. Consequently, excellent correspondence between TESS and reference spin echo data is observed for T2 in vitro at 1.5 T and in vivo at 3 T. TESS offers rapid T1 and T2 quantification within one single scan, and in particular B1 -insensitive T2 estimation. As a result, the new proposed method is of high interest for fast and reliable high-resolution T2 mapping, especially of the musculoskeletal system at high to ultra-high fields. Copyright © 2013 Wiley Periodicals, Inc.

  14. Searches for heavy resonances in all-jet final states with top quarks using jet substructure techniques with the CMS Experiment

    CERN Document Server

    Usai, Emanuele; Haller, Johannes

    2017-01-01

    While the Standard Model is very successful in describing subnuclear phenomena, it is not acomplete theory of particle physics. Several new theories have been developed to address itsissues. Many extensions of the Standard Model predict the existence of high-mass resonances.In some cases these resonances have an enhanced coupling to third generation quarks or toa hypothetical new generation of heavy non-chiral quarks. This thesis describes two searchesfor new phenomena compatible with these theories, in particular a search is presented forresonant top-antitop production, and the first search for heavy resonances decaying to a topquark and a heavy top quark partner T is shown.The searches target the all-jets decay channels and use data collected by the CMS Experiment at the CERN LHC between 2012 and 2015 at a center-of-mass energy of 8 TeV and13 TeV. Due to the high mass of the resonances considered, the final state particles have ahigh Lorentz-boost. To reconstruct the hadronic decay of the top quarks and W...

  15. About the Triple A. Argentina 1973 - 1976

    OpenAIRE

    Rostica, Julieta

    2011-01-01

    On May 25, 1973, Peronism returned to govern Argentina after about two decades of prohibition and political persecution. After its establishment, certain crimes began to be signed with “AAA”. The Triple A adopted the particularity of disappearing with the coup on March 24 1976. Why could this organization only exist in a democracy erected in the middle of two military dictatorships? Why did it exist during the very wished Peronist government? The article offers an approach to the Triple A, th...

  16. Synchrobetatron resonances

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    At the 1975 Particle Accelerator Conference it was reported that a class of resonances were observed in SPEAR II that had not appeared before in SPEAR I. These resonances occur when the betatron oscillation wave numbers ν/sub x/ or ν/sub y/ and the synchrotron wave number ν/sub s/ satisfy the relation (ν/sub x,y/ - mν/sub s/) = 5, with m an integer denoting the m/sup th/ satellite. The main difference between SPEAR II and SPEAR I is the value of ν/sub s/, which in SPEAR II is approximately 0.04, an order of magnitude larger than in SPEAR I. An ad hoc meeting was held at the 1975 Particle Accelerator Conference, where details of the SPEAR II results were presented and various possible mechanisms for producing these resonances were discussed. Later, experiments were performed at SPEAR to identify the mechanism believed to be the most likely explanation. Some of the current experimental knowledge and theoretical views on the source of these resonances are presented

  17. Surface-Enhanced Resonance Raman Scattering and Visible Extinction Spectroscopy of Copper Chlorophyllin: An Upper Level Chemistry Experiment

    Science.gov (United States)

    Schnitzer, Cheryl S.; Reim, Candace Lawson; Sirois, John J.; House, Paul G.

    2010-01-01

    Advanced chemistry students are introduced to surface-enhanced resonance Raman scattering (SERRS) by studying how sodium copper chlorophyllin (CuChl) adsorbs onto silver colloids (CuChl/Ag) as a function of pH. Using both SERRS and visible extinction spectroscopy, the extent of CuChl adsorption and colloidal aggregation are monitored. Initially at…

  18. The Development of an Innovative Resonance Experiment Using Smartphones with Free Mobile Software Applications for Tertiary Education

    Science.gov (United States)

    Abidin, Nurul Aina Syakirah Zainal; Tho, Siew Wei

    2018-01-01

    The purpose of this research was to design and develop hands-on practical physics activity for the determination of relationship between the fundamental frequency and wavelength of standing waves using open or closed resonance tubes. In this study, an innovative use of smartphone device for the hands-on practical activity was developed with the…

  19. Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostate.

    NARCIS (Netherlands)

    Fütterer, J.J.; Scheenen, T.W.J.; Huisman, H.J.; Klomp, D.W.J.; Dorsten, F.A. van; Hulsbergen-van de Kaa, C.A.; Witjes, J.A.; Heerschap, A.; Barentsz, J.O.

    2004-01-01

    RATIONALE AND OBJECTIVES: We sought to explore the feasibility of magnetic resonance imaging (MRI) of the prostate at 3T, with the knowledge of potential drawbacks of MRI at high field strengths. MATERIAL AND METHOD: MRI, dynamic MRI, and 1H-MR spectroscopic imaging were performed in 10 patients

  20. From double Chooz to triple Chooz - neutrino physics at the Chooz reactor complex

    International Nuclear Information System (INIS)

    Huber, Patrick; Kopp, Joachim; Lindner, Manfred; Rolinec, Mark; Winter, Walter

    2006-01-01

    We discuss the potential of the proposed Double Chooz reactor experiment to measure the neutrino mixing angle sin 2 2θ 13 . We especially consider systematical uncertainties and their partial cancellation in a near and far detector operation, and we discuss implications of a delayed near detector startup. Furthermore, we introduce Triple Chooz, which is a possible upgrade scenario assuming a second, larger far detector, which could start data taking in an existing cavern five years after the first far detector. We review the role of the Chooz reactor experiments in the global context of future neutrino beam experiments. We find that both Double Chooz and Triple Chooz can play a leading role in the search for a finite value of sin 2 2θ 13 . Double Chooz could achieve a sensitivity limit of ∼ 2.10 -2 at the 90% confidence level after 5 years while the Triple Chooz setup could give a sensitivity below 10 -2

  1. Integrating Compassionate, Collaborative Care (the "Triple C") Into Health Professional Education to Advance the Triple Aim of Health Care.

    Science.gov (United States)

    Lown, Beth A; McIntosh, Sharrie; Gaines, Martha E; McGuinn, Kathy; Hatem, David S

    2016-03-01

    Empathy and compassion provide an important foundation for effective collaboration in health care. Compassion (the recognition of and response to the distress and suffering of others) should be consistently offered by health care professionals to patients, families, staff, and one another. However, compassion without collaboration may result in uncoordinated care, while collaboration without compassion may result in technically correct but depersonalized care that fails to meet the unique emotional and psychosocial needs of all involved. Providing compassionate, collaborative care (CCC) is critical to achieving the "triple aim" of improving patients' health and experiences of care while reducing costs. Yet, values and skills related to CCC (or the "Triple C") are not routinely taught, modeled, and assessed across the continuum of learning and practice. To change this paradigm, an interprofessional group of experts recently recommended approaches and a framework for integrating CCC into health professional education and postgraduate training as well as clinical care. In this Perspective, the authors describe how the Triple C framework can be integrated and enhance existing competency standards to advance CCC across the learning and practice continuum. They also discuss strategies for partnering with patients and families to improve health professional education and health care design and delivery through quality improvement projects. They emphasize that compassion and collaboration are important sources of professional, patient, and family satisfaction as well as critical aspects of professionalism and person-centered, relationship-based high-quality care.

  2. Efficient amplitude-modulated pulses for triple- to single-quantum coherence conversion in MQMAS NMR.

    Science.gov (United States)

    Colaux, Henri; Dawson, Daniel M; Ashbrook, Sharon E

    2014-08-07

    The conversion between multiple- and single-quantum coherences is integral to many nuclear magnetic resonance (NMR) experiments of quadrupolar nuclei. This conversion is relatively inefficient when effected by a single pulse, and many composite pulse schemes have been developed to improve this efficiency. To provide the maximum improvement, such schemes typically require time-consuming experimental optimization. Here, we demonstrate an approach for generating amplitude-modulated pulses to enhance the efficiency of the triple- to single-quantum conversion. The optimization is performed using the SIMPSON and MATLAB packages and results in efficient pulses that can be used without experimental reoptimisation. Most significant signal enhancements are obtained when good estimates of the inherent radio-frequency nutation rate and the magnitude of the quadrupolar coupling are used as input to the optimization, but the pulses appear robust to reasonable variations in either parameter, producing significant enhancements compared to a single-pulse conversion, and also comparable or improved efficiency over other commonly used approaches. In all cases, the ease of implementation of our method is advantageous, particularly for cases with low sensitivity, where the improvement is most needed (e.g., low gyromagnetic ratio or high quadrupolar coupling). Our approach offers the potential to routinely improve the sensitivity of high-resolution NMR spectra of nuclei and systems that would, perhaps, otherwise be deemed "too challenging".

  3. Triple inverter pierce oscillator circuit suitable for CMOS

    Science.gov (United States)

    Wessendorf,; Kurt, O [Albuquerque, NM

    2007-02-27

    An oscillator circuit is disclosed which can be formed using discrete field-effect transistors (FETs), or as a complementary metal-oxide-semiconductor (CMOS) integrated circuit. The oscillator circuit utilizes a Pierce oscillator design with three inverter stages connected in series. A feedback resistor provided in a feedback loop about a second inverter stage provides an almost ideal inverting transconductance thereby allowing high-Q operation at the resonator-controlled frequency while suppressing a parasitic oscillation frequency that is inherent in a Pierce configuration using a "standard" triple inverter for the sustaining amplifier. The oscillator circuit, which operates in a range of 10 50 MHz, has applications for use as a clock in a microprocessor and can also be used for sensor applications.

  4. Resonant two-magnon Raman scattering in parent compounds of high-Tc superconductors

    International Nuclear Information System (INIS)

    Chubukov, A.V.; Frenkel, D.M.

    1995-01-01

    We propose a theory of two-magnon Raman scattering from the insulating parent compounds of high-T c superconductors, which contains information not only on magnetism, but also on the electronic properties in these materials. We use spin-density-wave formalism for the Hubbard model, and study diagrammatically the profile of the two-magnon scattering and its intensity dependence on the incoming photon frequency ω i both for ω i much-lt U and in the resonant regime, in which the energy of the incident photon is close to the gap between conduction and valence bands. In the nonresonant case, we identify the diagrams which contribute to the conventional Loudon-Fleury Hamiltonian. In the resonant regime, where most of the experiments have been done, we find that the dominant contribution to Raman intensity comes from a different diagram, one which allows for a simultaneous vanishing of all three of its dominators (i.e., a triple resonanc). We study this diagram in detail and show taht the triple resonance, combined with the spin-density-wave dispersion relation for the carriers, explains the unusual features found in the two-magnon profile and in the two-magnon peak intensity dependence on the incoming photon frequency. In particular, our theory predicts a maximum of the two-magnon peak intensity right at the upper edge of the features in the optical data, which has been one of the key experimental puzzles

  5. Role of magnetic resonance urography in diagnosis of duplex renal system: Our initial experience at a tertiary care institute

    Directory of Open Access Journals (Sweden)

    Milind P Joshi

    2009-01-01

    Full Text Available Aim: To determine diagnostic value of magnetic resonance urography in cases of duplex renal system. Method: Twenty cases between five month to nine years with suspected or known duplex renal system were evaluated by ultrasound (USG, micturating cystourethrography (MCU, intravenous urography (IVU and magnetic resonance urography (MRU. The findings of these diagnostic imaging studies were then compared with each other and against the results of final diagnosis established at surgery. Results: Duplex renal system could be identified in two of these cases on USG, was diagnosed in four in IVU and could be diagnosed in all cases with MRU. Conclusion: MRU is superior and far accurate than IVU, MCU and USG in diagnosing duplex renal system.

  6. Strange baryonic resonances below the anti KN threshold. Results from p+p reactions at the HADES experiment

    Energy Technology Data Exchange (ETDEWEB)

    Siebenson, Johannes Stephan

    2013-04-18

    The present work investigates the vacuum properties of the hyperon resonances {Sigma}(1385){sup +} and {Lambda}(1405). For this purpose, p+p reactions at 3.5 GeV kinetic beam energy were analyzed. By using simulations and a special background method, the Breit-Wigner mass and width of the {Sigma}(1385){sup +} could be determined. Furthermore, its production dynamics were studied in different angular distributions. In this context indications were found that the {Sigma}(1385){sup +} partially stems from the decay of a heavy {Delta}-resonance. The investigation of the {Lambda}(1405) was based on similar analysis methods. After acceptance and efficiency corrections, the spectral shape of the {Lambda}(1405) could be extracted. Here a mass shift of this particle to masses below 1400 MeV/c{sup 2} was found. This might reveal important information about the two pole structure of the {Lambda}(1405) and its influence on the low energy anti KN interaction.

  7. Structure of 12C and the triple-α process

    DEFF Research Database (Denmark)

    Fynbo, H.O.U.; Diget, C.Aa.

    2014-01-01

    We review experiments at IGISOL and associated work at ISOLDE and KVI on the use of the β-decays of 12N and 12B for the study of the structure of 12C and the consequences for the rate of the triple-α reaction in stars.......We review experiments at IGISOL and associated work at ISOLDE and KVI on the use of the β-decays of 12N and 12B for the study of the structure of 12C and the consequences for the rate of the triple-α reaction in stars....

  8. Physics of lateral triple quantum-dot molecules with controlled electron numbers.

    Science.gov (United States)

    Hsieh, Chang-Yu; Shim, Yun-Pil; Korkusinski, Marek; Hawrylak, Pawel

    2012-11-01

    We review the recent progress in theory and experiments with lateral triple quantum dots with controlled electron numbers down to one electron in each dot. The theory covers electronic and spin properties as a function of topology, number of electrons, gate voltage and external magnetic field. The orbital Hund's rules and Nagaoka ferromagnetism, magnetic frustration and chirality, interplay of quantum interference and electron-electron interactions and geometrical phases are described and related to charging and transport spectroscopy. Fabrication techniques and recent experiments are covered, as well as potential applications of triple quantum-dot molecule in coherent control, spin manipulation and quantum computation.

  9. Physics of lateral triple quantum-dot molecules with controlled electron numbers

    International Nuclear Information System (INIS)

    Hsieh, Chang-Yu; Shim, Yun-Pil; Korkusinski, Marek; Hawrylak, Pawel

    2012-01-01

    We review the recent progress in theory and experiments with lateral triple quantum dots with controlled electron numbers down to one electron in each dot. The theory covers electronic and spin properties as a function of topology, number of electrons, gate voltage and external magnetic field. The orbital Hund's rules and Nagaoka ferromagnetism, magnetic frustration and chirality, interplay of quantum interference and electron–electron interactions and geometrical phases are described and related to charging and transport spectroscopy. Fabrication techniques and recent experiments are covered, as well as potential applications of triple quantum-dot molecule in coherent control, spin manipulation and quantum computation. (review article)

  10. Off-resonance rotating-frame relaxation dispersion experiment for 13C in aromatic side chains using L-optimized TROSY-selection

    DEFF Research Database (Denmark)

    Weininger, Ulrich; Brath, Ulrika; Modig, Kristofer

    2014-01-01

    Protein dynamics on the microsecond-millisecond time scales often play a critical role in biological function. NMR relaxation dispersion experiments are powerful approaches for investigating biologically relevant dynamics with site-specific resolution, as shown by a growing number of publications...... on enzyme catalysis, protein folding, ligand binding, and allostery. To date, the majority of studies has probed the backbone amides or side-chain methyl groups, while experiments targeting other sites have been used more sparingly. Aromatic side chains are useful probes of protein dynamics, because...... they are over-represented in protein binding interfaces, have important catalytic roles in enzymes, and form a sizable part of the protein interior. Here we present an off-resonance R 1ρ experiment for measuring microsecond to millisecond conformational exchange of aromatic side chains in selectively (13)C...

  11. CACA-TOCSY with alternate 13C–12C labeling: a 13Cα direct detection experiment for mainchain resonance assignment, dihedral angle information, and amino acid type identification

    Science.gov (United States)

    Takeuchi, Koh; Frueh, Dominique P.; Sun, Zhen-Yu J.; Hiller, Sebastian

    2010-01-01

    We present a 13C direct detection CACA-TOCSY experiment for samples with alternate 13C–12C labeling. It provides inter-residue correlations between 13Cα resonances of residue i and adjacent Cαs at positions i − 1 and i + 1. Furthermore, longer mixing times yield correlations to Cα nuclei separated by more than one residue. The experiment also provides Cα-to-sidechain correlations, some amino acid type identifications and estimates for ψ dihedral angles. The power of the experiment derives from the alternate 13C–12C labeling with [1,3-13C] glycerol or [2-13C] glycerol, which allows utilizing the small scalar 3JCC couplings that are masked by strong 1JCC couplings in uniformly 13C labeled samples. PMID:20383561

  12. CACA-TOCSY with alternate 13C-12C labeling: a 13Cα direct detection experiment for mainchain resonance assignment, dihedral angle information, and amino acid type identification

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Frueh, Dominique P.; Sun, Zhen-Yu J.; Hiller, Sebastian; Wagner, Gerhard

    2010-01-01

    We present a 13 C direct detection CACA-TOCSY experiment for samples with alternate 13 C- 12 C labeling. It provides inter-residue correlations between 13 C α resonances of residue i and adjacent C α s at positions i - 1 and i + 1. Furthermore, longer mixing times yield correlations to C α nuclei separated by more than one residue. The experiment also provides C α -to-sidechain correlations, some amino acid type identifications and estimates for ψ dihedral angles. The power of the experiment derives from the alternate 13 C- 12 C labeling with [1,3- 13 C] glycerol or [2- 13 C] glycerol, which allows utilizing the small scalar 3 J CC couplings that are masked by strong 1 J CC couplings in uniformly 13 C labeled samples.

  13. CACA-TOCSY with alternate 13C-12C labeling: a 13Calpha direct detection experiment for mainchain resonance assignment, dihedral angle information, and amino acid type identification.

    Science.gov (United States)

    Takeuchi, Koh; Frueh, Dominique P; Sun, Zhen-Yu J; Hiller, Sebastian; Wagner, Gerhard

    2010-05-01

    We present a (13)C direct detection CACA-TOCSY experiment for samples with alternate (13)C-(12)C labeling. It provides inter-residue correlations between (13)C(alpha) resonances of residue i and adjacent C(alpha)s at positions i - 1 and i + 1. Furthermore, longer mixing times yield correlations to C(alpha) nuclei separated by more than one residue. The experiment also provides C(alpha)-to-sidechain correlations, some amino acid type identifications and estimates for psi dihedral angles. The power of the experiment derives from the alternate (13)C-(12)C labeling with [1,3-(13)C] glycerol or [2-(13)C] glycerol, which allows utilizing the small scalar (3)J(CC) couplings that are masked by strong (1)J(CC) couplings in uniformly (13)C labeled samples.

  14. Sensitivity improvement for correlations involving arginine side-chain Nε/Hε resonances in multi-dimensional NMR experiments using broadband 15N 180o pulses

    International Nuclear Information System (INIS)

    Iwahara, Junji; Clore, G. Marius

    2006-01-01

    Due to practical limitations in available 15 N rf field strength, imperfections in 15 N 180 o pulses arising from off-resonance effects can result in significant sensitivity loss, even if the chemical shift offset is relatively small. Indeed, in multi-dimensional NMR experiments optimized for protein backbone amide groups, cross-peaks arising from the Arg guanidino 15 Nε (∼85 ppm) are highly attenuated by the presence of multiple INEPT transfer steps. To improve the sensitivity for correlations involving Arg Nε-Hε groups, we have incorporated 15 N broadband 180 deg. pulses into 3D 15 N-separated NOE-HSQC and HNCACB experiments. Two 15 N-WURST pulses incorporated at the INEPT transfer steps of the 3D 15 N-separated NOE-HSQC pulse sequence resulted in a ∼1.5-fold increase in sensitivity for the Arg Nε-Hε signals at 800 MHz. For the 3D HNCACB experiment, five 15 N Abramovich-Vega pulses were incorporated for broadband inversion and refocusing, and the sensitivity of Arg 1 Hε- 15 Nε- 13 Cγ/ 13 Cδ correlation peaks was enhanced by a factor of ∼1.7 at 500 MHz. These experiments eliminate the necessity for additional experiments to assign Arg 1 Hε and 15 Nε resonances. In addition, the increased sensitivity afforded for the detection of NOE cross-peaks involving correlations with the 15 Nε/ 1 Hε of Arg in 3D 15 N-separated NOE experiments should prove to be very useful for structural analysis of interactions involving Arg side-chains

  15. Entangling distant resonant exchange qubits via circuit quantum electrodynamics

    Science.gov (United States)

    Srinivasa, V.; Taylor, J. M.; Tahan, Charles

    2016-11-01

    We investigate a hybrid quantum system consisting of spatially separated resonant exchange qubits, defined in three-electron semiconductor triple quantum dots, that are coupled via a superconducting transmission line resonator. Drawing on methods from circuit quantum electrodynamics and Hartmann-Hahn double resonance techniques, we analyze three specific approaches for implementing resonator-mediated two-qubit entangling gates in both dispersive and resonant regimes of interaction. We calculate entangling gate fidelities as well as the rate of relaxation via phonons for resonant exchange qubits in silicon triple dots and show that such an implementation is particularly well suited to achieving the strong coupling regime. Our approach combines the favorable coherence properties of encoded spin qubits in silicon with the rapid and robust long-range entanglement provided by circuit QED systems.

  16. Early experience with X-ray magnetic resonance fusion for low-flow vascular malformations in the pediatric interventional radiology suite

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Tiffany J. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Keck School of Medicine of the University of Southern California, Los Angeles, CA (United States); Girard, Erin [Siemens Corporation, Corporate Technology, Princeton, NJ (United States); Shellikeri, Sphoorti; Vossough, Arastoo; Ho-Fung, Victor; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Setser, Randolph [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States)

    2016-03-15

    This technical innovation describes our experience using an X-ray magnetic resonance fusion (XMRF) software program to overlay 3-D MR images on real-time fluoroscopic images during sclerotherapy procedures for vascular malformations at a large pediatric institution. Five cases have been selected to illustrate the application and various clinical utilities of XMRF during sclerotherapy procedures as well as the technical limitations of this technique. The cases demonstrate how to use XMRF in the interventional suite to derive additional information to improve therapeutic confidence with regards to the extent of lesion filling and to guide clinical management in terms of intraprocedural interventional measures. (orig.)

  17. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    OBJECTIVES: The purpose of this study was to investigate the detection rate of prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsies (mp-MRI-bx) in patients with prior negative transrectal ultrasound biopsy (TRUS-bx) sessions without previous experience of this......-RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...

  18. The Role of Wrist Magnetic Resonance Arthrography in Diagnosing Triangular Fibrocartilage Complex Tears; Experience at King Hussein Medical Center, Jordan

    Directory of Open Access Journals (Sweden)

    Asem A. Al-Hiari

    2013-05-01

    Full Text Available Objectives: The aims of the study were to evaluate the role of magnetic resonance arthrography (MRA of the wrist in detecting full-thickness tears of the triangular fibrocartilage complex (TFCC and to compare the results of the magnetic resonance arthrography (MRA with the gold standard arthroscopic findings. Methods:The study was performed at King Hussein Medical Center, Amman, Jordan, between January 2008 and December 2011. A total of 42 patients (35 males and 7 females who had ulnar-sided wrist pain and clinical suspicions of TFCC tears were included in the study. All patients underwent wrist magnetic resonance arthrography (MRA and then a wrist arthroscopy. The results of MRA were compared with the arthroscopic findings. Results: After comparison with the arthroscopic findings, the MRA had three false-negative results (sensitivity = 93% and no false-positive results. A total of 39 patients were able to return to work. Satisfaction was high in 38 of the patients and 33 had satisfactorypain relief. The sensitivity of the wrist MRA in detecting TFCC full-thickness tears was 93% (39, and specificity was 80% (16/20. The overall accuracy of wrist arthroscopy in detecting a full-thickness tear of the TFCC in our study was 85% (29/34. Conclusion: These results illustrate the role of wrist MRA in assessing the TFCC pathology and suggest its use as the first imaging technique, following a plain X-ray, in evaluating patients with chronic ulnar side wrist pain with suspected TFCC injuries.

  19. Fourier photospectroscopy of Xe-C{sub 60} through a Xe 4d resonance window: theory versus recent experiment

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Aakash B; Chakraborty, Himadri S, E-mail: himadri@nwmissouri.edu [Center for Innovation and Entrepreneurship, Department of Chemistry and Physics, Northwest Missouri State University, Maryville, Missouri 64468 (United States)

    2011-10-14

    The photoionization cross section of endohedral Xe-C{sub 60} over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  20. Fourier photospectroscopy of Xe-C60 through a Xe 4d resonance window: theory versus recent experiment

    International Nuclear Information System (INIS)

    Patel, Aakash B; Chakraborty, Himadri S

    2011-01-01

    The photoionization cross section of endohedral Xe-C 60 over a Xe 4d giant resonance energy region, calculated in the time-dependent local density approximation, is compared with recent measurements (Kilcoyne et al 2010 Phys. Rev. Lett. 105 213001). An analysis based on the Fourier transforms of oscillatory cross sections is performed to derive a number of inherent similarities between the prediction and the data, including a large beating-type oscillation and several others of intermediate size. Results stress the need for more accurate measurements to access the wealth of information about the geometry of the system. (fast track communication)

  1. Cholangiopancreatography for magnetic resonance (CPRM), using T2 - TSE technique and reconstructions 3D - Experience with 38 patients

    International Nuclear Information System (INIS)

    Esguerra Espinosa, Monica

    1997-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive diagnostic method for the study of the biliary system that does not require contrast media or exposure to ionising radiation. Thirty-eight patients were studied; five apparently healthy ones only with MRCP; and 33 with possible biliary tract pathology, most of which had both endoscopes retrograde cholangiopancreatogaphy (ERCP) and MRCP: All MRCP's were performed with a 3D - TSE sequence with T2 - weighting, using coronal thin contiguous slices and reconstructions with maximal intensity projections (MIP) on different planes. MRCP allows an excellent anatomic depiction of the biliary tree and pancreatic duct

  2. Whistler mode resonance-cone transmissions at 100 kHz in the OEDIPUS-C experiment

    Czech Academy of Sciences Publication Activity Database

    Chugunov, Y. V.; Fiala, Vladimír; Hayosh, Mykhaylo; James, H. G.

    2012-01-01

    Roč. 47, č. 6 (2012), RS6002/1-RS6002/11 ISSN 0048-6604 Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100420904 Program:M Institutional support: RVO:68378289 Keywords : OEDIPUS-C * dipole * pulse distortion * resonance cone * whistler mode Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.000, year: 2012 http://onlinelibrary.wiley.com/doi/10.1029/2012RS005054/abstract

  3. Krein Spectral Triples and the Fermionic Action

    International Nuclear Information System (INIS)

    Dungen, Koen van den

    2016-01-01

    Motivated by the space of spinors on a Lorentzian manifold, we define Krein spectral triples, which generalise spectral triples from Hilbert spaces to Krein spaces. This Krein space approach allows for an improved formulation of the fermionic action for almost-commutative manifolds. We show by explicit calculation that this action functional recovers the correct Lagrangians for the cases of electrodynamics, the electro-weak theory, and the Standard Model. The description of these examples does not require a real structure, unless one includes Majorana masses, in which case the internal spaces also exhibit a Krein space structure.

  4. Analysis of resonances due to 'S' neutrons in experiments on transmission by time-of-flight. 1. without the interference term; Analyse des resonances dues aux neutrons 'S' dans les experiences de transmission par temps de vol. 1. sans terme d'interference

    Energy Technology Data Exchange (ETDEWEB)

    Corge, C R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Various methods of transmission resonance analysis for 's' wave neutrons in time of flight experiments are described in this report. Only the case when the interference term can be neglected is treated in this first part. Results are given relative to a more complete partial area method and also to a new method so-called the width at half depth method. (author) [French] Le present rapport est consacre a l'expose de differentes methodes d'analyse des resonances dues aux neutrons d'ondes 's' dans les experiences de transmission par temps de vol, cette premiere partie traitant uniquement le cas ou l'on peut negliger le terme d'interference. Y figurent en particulier sous forme de reseaux de courbes, les resultats relatifs a une methode des aires partielles amelioree et ceux relatifs a une nouvelle methode dite de la largeur a mi-profondeur. (auteur)

  5. Analysis methods of neutrons induced resonances in the transmission experiments by time-of-flight and automation of these methods on IBM 7094 II computer; Methode d'analyse des resonances induites par les neutrons dans les experiences de transmission par temps-de-vol et automatisation de ces methodes sur ordinateur IBM-7094 II

    Energy Technology Data Exchange (ETDEWEB)

    Corge, C

    1967-07-01

    The neutron induced resonances analysis aims to determine the neutrons characteristics, leading to the excitation energies, de-excitation probabilities by gamma radiation emission, by neutron emission or by fission, their spin, their parity... This document describes the methods developed, or adapted, the calculation schemes and the algorithms implemented to realize such analysis on a computer, from data obtained during time-of-flight experiments on the linear accelerator of Saclay. (A.L.B.)

  6. Analysis methods of neutrons induced resonances in the transmission experiments by time-of-flight and automation of these methods on IBM 7094 II computer; Methode d'analyse des resonances induites par les neutrons dans les experiences de transmission par temps-de-vol et automatisation de ces methodes sur ordinateur IBM-7094 II

    Energy Technology Data Exchange (ETDEWEB)

    Corge, C

    1967-07-01

    The neutron induced resonances analysis aims to determine the neutrons characteristics, leading to the excitation energies, de-excitation probabilities by gamma radiation emission, by neutron emission or by fission, their spin, their parity... This document describes the methods developed, or adapted, the calculation schemes and the algorithms implemented to realize such analysis on a computer, from data obtained during time-of-flight experiments on the linear accelerator of Saclay. (A.L.B.)

  7. J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images.

    Science.gov (United States)

    Khang, Hyun Soo; Lee, Byung Il; Oh, Suk Hoon; Woo, Eung Je; Lee, Soo Yeol; Cho, Min Hyoung; Kwon, Ohin; Yoon, Jeong Rock; Seo, Jin Keun

    2002-06-01

    Recently, a new static resistivity image reconstruction algorithm is proposed utilizing internal current density data obtained by magnetic resonance current density imaging technique. This new imaging method is called magnetic resonance electrical impedance tomography (MREIT). The derivation and performance of J-substitution algorithm in MREIT have been reported as a new accurate and high-resolution static impedance imaging technique via computer simulation methods. In this paper, we present experimental procedures, denoising techniques, and image reconstructions using a 0.3-tesla (T) experimental MREIT system and saline phantoms. MREIT using J-substitution algorithm effectively utilizes the internal current density information resolving the problem inherent in a conventional EIT, that is, the low sensitivity of boundary measurements to any changes of internal tissue resistivity values. Resistivity images of saline phantoms show an accuracy of 6.8%-47.2% and spatial resolution of 64 x 64. Both of them can be significantly improved by using an MRI system with a better signal-to-noise ratio.

  8. Evaluation of the Beneficial Effects of Triple Intercropping of Maize (Zea mays L., Pinto Been (Phaseolus vulgaris L.

    Directory of Open Access Journals (Sweden)

    P. Moradi

    2016-05-01

    Full Text Available In order to evaluate the benefits of maize, pinto bean and naked pumpkin triple cropping, an experiment was carried out as a randomized complete block design with three replications at Faculty of Agricultural Science, University of Guilan, Rasht, Iran in 2012. The treatments consisted of maize, pinto bean and naked pumpkin sole cropping (100, 75 and 50% of conventional densities, maize – pinto bean and maize – pumpkin double cropping (100-100%, 75-75% and 50-50%, and maize-pinto bean-pumpkin triple cropping (100-100-100%, 75-75-75% and 50-50-50%. The highest and lowest forage fresh weights were obtained in triple cropping system with high density and sole cropping systems with low density, respectively. In double cropping systems, the maize-pumpkin out-yielded the maize-pinto bean in terms of fresh weight. The relative crowding coefficient, competitive ratio and aggressivity of maize in double cropping of maize-pinto bean and naked pumpkin in double cropping of maize-naked pumpkin were dominant. In triple cropping systems, while maize and naked pumpkin were comparable, but both of the latter crops were dominant over pinto bean. Land Equivalent Ratio (LER for double and triple cropping was greater than one, revealing the profitability of double and triple cropping systems on sole cropping. According to the LER, the cropping systems can be ranked as follows: triple cropping > double cropping maize/pinto bean > double cropping maize/pumpkin

  9. Electron paramagnetic resonance

    CERN Document Server

    Al'tshuler, S A

    2013-01-01

    Electron Paramagnetic Resonance is a comprehensive text on the field of electron paramagnetic resonance, covering both the theoretical background and the results of experiment. This book is composed of eight chapters that cover theoretical materials and experimental data on ionic crystals, since these are the materials that have been most extensively studied by the methods of paramagnetic resonance. The opening chapters provide an introduction to the basic principles of electron paramagnetic resonance and the methods of its measurement. The next chapters are devoted to the theory of spectra an

  10. Triple helix interactions for eco-innovation

    DEFF Research Database (Denmark)

    Hermann, Roberto Rivas; Riisgaard, Henrik; Remmen, Arne

    the role of science parks in promoting eco-innovation. This study uses qualitative data gathered in two units of analysis: Panama Canal Authority and City of Knowledge Science Park. The study examines how Triple Helix interactions have built the regional system of eco-innovation at the Panama Canal...

  11. Triple-axis spectrometer DruechaL

    International Nuclear Information System (INIS)

    Buehrer, W.; Keller, P.

    1996-01-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs

  12. A Biatrial Myxoma with Triple Ripples.

    Science.gov (United States)

    Barik, Ramachandra

    2018-01-01

    Cardiac myxoma is a benign tumor, but it is known for its space-occupying effect at the site of origin and frequent systemic embolization. This case report highlights a biatrial myxoma of interatrial septum who presented with significant tricuspid valve regurgitation, atrial fibrillation, and cardioembolic stroke of the left parietal lobe, i.e., a biatrial myxoma with triple ripples.

  13. Revised Reynolds Stress and Triple Product Models

    Science.gov (United States)

    Olsen, Michael E.; Lillard, Randolph P.

    2017-01-01

    Revised versions of Lag methodology Reynolds-stress and triple product models are applied to accepted test cases to assess the improvement, or lack thereof, in the prediction capability of the models. The Bachalo-Johnson bump flow is shown as an example for this abstract submission.

  14. Minimal representations and Freudenthal triple systems

    International Nuclear Information System (INIS)

    Olive, D.

    2004-01-01

    Unitary representations of noncompact Lie groups have long been sought in physics. The first nice concrete construction was found by Dirac in connection with the anti-de Sitter group. Some subsequent generalizations will be described, in particular the minimal representation thought to be relevant to realising duality in supergravity superstring theories. A relation to Freudenthal triple systems will be described. (author)

  15. Triple-axis spectrometer DruechaL

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W; Keller, P [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    DruechaL is a triple-axis spectrometer located at a cold guide. The characteristics of guide and instrument allow the use of a broad spectral range of neutrons. The resolution in momentum and energy transfer can be tuned to match the experimental requirements by using either collimators or focusing systems (monochromator, antitrumpet, analyser). (author) figs., tabs., refs.

  16. Discovering Steiner Triple Systems through Problem Solving

    Science.gov (United States)

    Sriraman, Bharath

    2004-01-01

    An attempt to implement problem solving as a teacher of ninth grade algebra is described. The problems selected were not general ones, they involved combinations and represented various situations and were more complex which lead to the discovery of Steiner triple systems.

  17. [Analysis of experience in the use of dynamic pelvic magnetic resonance imaging in the assessment of obstructive defaecation syndrome].

    Science.gov (United States)

    Martín Martín, Gonzalo; García Armengol, Juan; Roig Vila, José Vicente; García Coret, María José; Martínez Sanjuán, Vicente; Almela Notari, Pedro; Mínguez Pérez, Miguel

    2012-05-01

    The aetiological diagnosis of obstructive defaecation syndrome (ODS) requires, among others, imaging tests. The purpose of this study is to descriptively analyse and compare the findings of dynamic pelvic magnetic resonance imaging (DPMRI) with the clinical examinations in patients with ODS. A prospective comparative study was made between the physical examination and the DPMRI, with a descriptive analysis of the results. A total of 30 patients were included (2 males and 28 females), with a median age of 60 (range 23-76) years, with symptoms of ODS. An anamnesis and detailed physical examination and a DPMRI were performed on all of them. Functional (anismus) and morphological changes (rectocele, enterocele, intussusception, etc.), were analysed. The physical examination did not detect anomalies in 6 (20%) patients. A rectocele was diagnosed in 21 (70%) of the cases, and 2 (6.7%) a rectal mucosal prolapse. The DPMRI showed evidence of pelvic floor laxity in 22 (73.3%) cases, an enterocele in 4 (13.3%), a sigmoidocele in 2 (6.7%), intussusception in 8 (26.7%), rectal mucosal prolapse in 4 (13.3%), anismus in 3 (10%), and a cystocele in 4 (13.3%). The rectocele was the most frequent diagnosis, being given in 26 (86.6%) patients. Magnetic resonance imaging provides an overall pelvic assessment with good definition of the tissues, and does not use ionising radiation, is well tolerated, and provides us with complementary information to arrive at the diagnosis, and establish the best treatment for ODS. Larger studies comparing videodefaecography (VD), currently considered the Gold Standard technique, are needed to be able to demonstrate whether it is superior or not to DPMRI. Copyright © 2011 AEC. Published by Elsevier Espana. All rights reserved.

  18. Triple superphosphate obtaining from Bayovar phosphoric rock and labelling with P-32

    International Nuclear Information System (INIS)

    Rodriguez, J.

    1983-01-01

    In view of the fact that in Peru the triple superphosphate utilized is an imported product and that, on the other hand, the phospherous rocks of Bayovar contain an average of 18% of P 2 O 5 , a process of enrichment was carried out in order to obtain at an experimental level the triple superphosphate having the necessary requirements for agricultural use. At a later stage the product obtained was labelled with P-32. To verify the experiment, phosphor was extracted in continuous fractionated form and at the same time colorimetric determinations with the method of the Vanado-Molibdo-Phosphor were carried out

  19. Added flexibility in triple axis spectrometers: The two RITAs at Risø

    DEFF Research Database (Denmark)

    Lefmann, K.; McMorrow, D.F.; Rønnow, H.M.

    2000-01-01

    The cold-neutron triple-axis spectrometer RITA-I at Rise has been operational for about three years, and in the near future an improved version, RITA-2 will replace the existing triple-axis instrument TAS7. We review the performance of RITA-1 and the operation modes of its flexible secondary...... spectrometer, giving examples of a few key experiments, and describe the software developed for running it. Further, the design of the new RITA-2 instrument is presented. The two RITA spectrometers are compared with their sister instrument SPINS at NIST and with similar instruments planned elsewhere. (C) 2000...

  20. Triple oxygen isotope systematics of structurally bonded water in gypsum

    Science.gov (United States)

    Herwartz, Daniel; Surma, Jakub; Voigt, Claudia; Assonov, Sergey; Staubwasser, Michael

    2017-07-01

    The triple oxygen isotopic composition of gypsum mother water (gmw) is recorded in structurally bonded water in gypsum (gsbw). Respective fractionation factors have been determined experimentally for 18O/16O and 17O/16O. By taking previous experiments into account we suggest using 18αgsbw-gmw = 1.0037; 17αgsbw-gmw = 1.00195 and θgsbw-gmw = 0.5285 as fractionation factors in triple oxygen isotope space. Recent gypsum was sampled from a series of 10 ponds located in the Salar de Llamara in the Atacama Desert, Chile. Total dissolved solids (TDS) in these ponds show a gradual increase from 23 g/l to 182 g/l that is accompanied by an increase in pond water 18O/16O. Gsbw falls on a parallel curve to the ambient water from the saline ponds. The offset is mainly due to the equilibrium fractionation between gsbw and gmw. However, gsbw represents a time integrated signal biased towards times of strong evaporation, hence the estimated gmw comprises elevated 18O/16O compositions when compared to pond water samples taken on site. Gypsum precipitation is associated with algae mats in the ponds with lower salinity. No evidence for respective vital effects on the triple oxygen isotopic composition of gypsum hydration water is observed, nor are such effects expected. In principle, the array of δ18Ogsbw vs. 17Oexcess can be used to: (1) provide information on the degree of evaporation during gypsum formation; (2) estimate pristine meteoric water compositions; and (3) estimate local relative humidity which is the controlling parameter of the slope of the array for simple hydrological situations. In our case study, local mining activities may have decreased deep groundwater recharge, causing a recent change of the local hydrology.

  1. MDP-based resource allocation for triple-play transmission on xDSL systems

    Science.gov (United States)

    de Souza, Lamartine V.; de Carvalho, Glaucio H. S.; Cardoso, Diego L.; de Carvalho, Solon V.; Frances, Carlos R. L.; Costa, João C. W. A.; Riu, Jaume Rius i.

    2007-09-01

    Many broadband services are based on multimedia applications, such as voice over internet protocol (VoIP), video conferencing, video on demand (VoD), and internet protocol television (IPTV). The combination "triple-play" is often used with IPTV. It simply means offering voice, video and data. IPTV and others services uses digital broadband networks such as ADSL2+ (Asymmetric Digital Subscriber Line) and VDSL (Very High Rate DSL) to transmit the data. We have formulated a MDP (Markov Decision Process) for a triple-play transmission on DSL environment. In this paper, we establish the relationship between DSL transmission characteristics and its finite-state Markov model for a triple-play transmission system. This relationship can be used for a resource management for multimedia applications delivered through a broadband infrastructure. The solution to our optimization problem can be found using dynamic programming (DP) techniques, such as value iteration and its variants. Our study results in a transmission strategy that chooses the optimal resource allocation according the triple-play traffic requirements, defined in technical report TR-126 (Triple-Play Services Quality of Experience Requirements) from DSL Forum, minimizing quality of service (QoS) violations with respect to bandwidth. Three traffic classes (video, audio, and best effort internet data) are defined and analyzed. Our simulation results show parameters like as blocking probability for each class, link utilization and optimal control policies. The MDP-based approach provides a satisfactory way of resource management for a DSL system.

  2. Genesis of Karl Popper's EPR-like experiment and its resonance amongst the physics community in the 1980s

    Science.gov (United States)

    Del Santo, Flavio

    2018-05-01

    I present the reconstruction of the involvement of Karl Popper in the community of physicists concerned with foundations of quantum mechanics, in the 1980s. At that time Popper gave active contribution to the research in physics, of which the most significant is a new version of the EPR thought experiment, alleged to test different interpretations of quantum mechanics. The genesis of such an experiment is reconstructed in detail, and an unpublished letter by Popper is reproduced in the present paper to show that he formulated his thought experiment already two years before its first publication in 1982. The debate stimulated by the proposed experiment as well as Popper's role in the physics community throughout 1980s is here analysed in detail by means of personal correspondence and publications.

  3. HNCA-TOCSY-CANH experiments with alternate 13C-12C labeling: a set of 3D experiment with unique supra-sequential information for mainchain resonance assignment

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Gal, Maayan; Takahashi, Hideo; Shimada, Ichio; Wagner, Gerhard

    2011-01-01

    Described here is a set of three-dimensional (3D) NMR experiments that rely on CACA-TOCSY magnetization transfer via the weak 3 J(C α C α ) coupling. These pulse sequences, which resemble recently described 13 C detected CACA-TOCSY (Takeuchi et al. 2010) experiments, are recorded in 1 H 2 O, and use 1 H excitation and detection. These experiments require alternate 13 C- 12 C labeling together with perdeuteration, which allows utilizing the small 3 J(C α C α ) scalar coupling that is otherwise masked by the stronger 1 J CC couplings in uniformly 13 C labeled samples. These new experiments provide a unique assignment ladder-mark that yields bidirectional supra-sequential information and can readily straddle proline residues. Unlike the conventional HNCA experiment, which contains only sequential information to the 13 (C α ) of the preceding residue, the 3D hnCA-TOCSY-caNH experiment can yield sequential correlations to alpha carbons in positions i−1, i + 1 and i−2. Furthermore, the 3D hNca-TOCSY-caNH and Hnca-TOCSY-caNH experiments, which share the same magnetization pathway but use a different chemical shift encoding, directly couple the 15 N- 1 H spin pair of residue i to adjacent amide protons and nitrogens at positions i−2, i−1, i + 1 and i + 2, respectively. These new experimental features make protein backbone assignments more robust by reducing the degeneracy problem associated with the conventional 3D NMR experiments.

  4. Triple A (Allgrove) syndrome: an unusual association with syringomyelia

    Science.gov (United States)

    2013-01-01

    Triple A (Allgrove) syndrome was first described by Allgrove in 1978 in two pairs of siblings. Since then, about 100 cases have been reported, all of them displaying an autosomal recessive pattern of inheritance. Clinical picture is characterized by achalasia, alacrimia and ACTH-resistant adrenal failure. A progressive neurological syndrome including central, peripheral and autonomic nervous system impairment, and mild mental retardation is often associated. The triple A syndrome gene, designated AAAS, is localized on chromosome 12q13. It consists of 16 exons, encoding for a 546 aminoacid protein called ALADIN (Alacrimia-Achalasia-aDrenal Insufficiency Neurologic disorder). We report on a 13 year-old boy presenting with Addison’s disease, dysphagia, muscle weakness, excessive fatigue and recent onset gait ataxia. The analysis of the AAAS gene revealed a homozygous missense mutation in exon 12. It was a T > G transversion at nucleotide position 1224, resulting in a change of leucine at amino acid position 381 into arginine (Leu381Arg or L381R). Brain appearance was found normal at magnetic resonance imaging (MRI) and functional spectroscopy analysis showed normal levels of the main metabolites. Spine MRI showed a cystic cavity within the spinal cord (syringomyelia), localized between the sixth cervical vertebra and the first thoracic vertebra. Cerebellar tonsils descended 7 mm caudal to foramen magnum, consistently with a mild type 1 Chiari malformation. Mild posterior inter-vertebral disk protrusions were evident between T9 and T10 and between L4 and L5. To our knowledge, this is the first report describing type 1 Chiari malformation and multiple spinal cord abnormalities in a patient with Allgrove syndrome. PMID:23800107

  5. Study of Υ family resonances in ultrarelativistic heavy ions collisions within the frame of the Alice experiment at CERN-LHC

    International Nuclear Information System (INIS)

    Dumonteil, E.

    2004-09-01

    Quantum Chromodynamics foresees, at high temperature and/or high energy density, a phase transition between hadronic matter and a phase where quarks and gluons are no more confined in the nucleons: the Quark Gluon Plasma (QGP). During the past fifteen years, a large experimental program has taken place at CERN and at BNL, to identify the QGP. ALICE is the LHC experiment dedicated to the study of the plasma via ultrarelativistic heavy ion collisions at 2.75 TeV/nucleon per beam. The measure of Upsilon's resonances suppression, a powerful signature of a deconfined medium, with the ALICE dimuon spectrometer, is the main topic of this thesis. The first part of the work aims at studying the multi-wires pad chambers of the dimuon arm, used to track the muons from resonances decays. The second part presents an in-beam alignment algorithm able to calculate the positions of the different chambers with a very good accuracy. Finally, the last part proposes a study to lead with the ALICE muon spectrometer, involving the measure of Upsilon and Upsilon's production ratio as a function of the transverse momentum. It has been showed that this study should allow to evidence the QGP and to extract some of its properties. (author)

  6. Cancer and diverticulitis of the sigmoid colon. Differentiation with computed tomography versus magnetic resonance imaging - Preliminary experiences

    Energy Technology Data Exchange (ETDEWEB)

    Oeistaemoe, Emma; Hjern, Fredrik; Abraham-Nordling, Mirna [Dept. of Clinical Sciences, Div. of Surgery, Danderyd Hospital, Karolinska Institutet, Stockholm (Sweden)], e-mail: mirna.abraham.nordling@ki.se; Blomqvist, Lennart [Dept. of Diagnostic Radiology, Dept. of Molecular Medicine and Surgery Karolinska Univ. Hospital Solna and Karolinska Institutet, Stockholm (Sweden); Von Heijne, Anders [Dept. of Clinical Sciences, Div. of Radiology, Danderyd Hospital, Karolinska Institutet, Stockholm (Sweden)

    2013-04-15

    Background: Both colon cancer and diverticular disease are common in the Western world. A challenge when patients present with clinical findings is that both diseases can present with symptoms that may mimic the other. Purpose: To determine whether magnetic resonance imaging (MRI) could be helpful to differentiate between diverticulitis and cancer of the sigmoid colon compared to the differentiation offered by evaluation of multidetector computed tomography (CT) in a clinical situation. Material and Methods: Thirty patients were consecutively included. Fifteen patients were under work-up for a recently diagnosed sigmoid cancer and 15 patients had recently been treated in hospital due to first-time acute sigmoid diverticulitis. All patients underwent CT, T2- weighted MRI and diffusion-weighted MRI. Anonymized examinations were retrospectively presented in random order to one experienced radiologist. Results: With contrast-enhanced CT, the sensitivity and specificity for diagnosis of cancer and diverticulitis were 66.7% (10/15) and 93.3% (14/15), respectively. Using T2-weighted and diffusion-weighted MR images, the sensitivity and specificity for diagnosis of cancer and diverticulitis were 100% (14/14) and 100% (14/14), respectively. Conclusion: MRI provides information that may contribute to improve the differentiation between sigmoid cancer and diverticulitis that is offered by CT. These encouraging results need to be confirmed in a larger study.

  7. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Karmonik, C.; Benndorf, G. [The Methodist Hospital Research Inst., Houston (United States). Radiology; Klucznik, R. [The Methodist Hospital, Houston (United States). Radiology

    2008-03-15

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. {+-}60 to {+-}100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  8. Intra-epiphyseal stress injury of the proximal tibial epiphysis: Preliminary experience of magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Tony, G., E-mail: drgtony@gmail.com [Stafford General Hospital, Weston Road, Stafford, Staffordshire ST16 3SA (United Kingdom); Charran, A., E-mail: amandacharran@yahoo.com [Hillingdon Hospital, Pield Heath Rd, Uxbridge, Middlesex UB8 3NN (United Kingdom); Tins, B., E-mail: bernhard.tins@rjah.nhs.uk [Department of Diagnostic Imaging, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Lalam, R., E-mail: radhesh.lalam@rjah.nhs.uk [Department of Diagnostic Imaging, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Tyrrell, P.N.M., E-mail: prudencia.tyrrell@rjah.nhs.uk [Department of Diagnostic Imaging, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Singh, J., E-mail: jaspreet.singh@rjah.nhs.uk [Department of Diagnostic Imaging, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Cool, P., E-mail: paul.cool@rjah.nhs.uk [Orthopaedic Oncology, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Kiely, N., E-mail: nigel.kiely@rjah.nhs.uk [Paediatric Orthopaedics, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom); Cassar-Pullicino, V.N., E-mail: Victor.Pullicino@rjah.nhs.uk [Department of Diagnostic Imaging, Robert Jones and Agnes Hunt, Orthopaedic Hospital, Oswestry, Shropshire SY10 7 AG (United Kingdom)

    2014-11-15

    Highlights: • Purely intra-epiphyseal stress injuries of the proximal tibial epiphysis are described for the first time. • The variation in the MRI findings of these injuries depending on the stage of maturation is demonstrated. • We postulate a patho-mechanism to explain the variations in site and appearance of stress injuries in this region. - Abstract: Stress induced injuries affecting the physeal plate or cortical bone in children and adolescents, especially young athletes, have been well described. However, there are no reports in the current English language literature of stress injury affecting the incompletely ossified epiphyseal cartilage. We present four cases of stress related change to the proximal tibial epiphysis (PTE) along with their respective magnetic resonance imaging (MRI) appearances ranging from subtle oedema signal to a pseudo-tumour like appearance within the epiphyseal cartilage. The site and pattern of intra-epiphyseal injury is determined by the type of tissue that is affected, the maturity of the skeleton and the type of forces that are transmitted through the tissue. We demonstrate how an awareness of the morphological spectrum of MRI appearances in intra-epiphyseal stress injury and the ability to identify concomitant signs of stress in other nearby structures can help reduce misdiagnosis, avoid invasive diagnostic procedures like bone biopsy and reassure patients and their families.

  9. Intra-epiphyseal stress injury of the proximal tibial epiphysis: Preliminary experience of magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Tony, G.; Charran, A.; Tins, B.; Lalam, R.; Tyrrell, P.N.M.; Singh, J.; Cool, P.; Kiely, N.; Cassar-Pullicino, V.N.

    2014-01-01

    Highlights: • Purely intra-epiphyseal stress injuries of the proximal tibial epiphysis are described for the first time. • The variation in the MRI findings of these injuries depending on the stage of maturation is demonstrated. • We postulate a patho-mechanism to explain the variations in site and appearance of stress injuries in this region. - Abstract: Stress induced injuries affecting the physeal plate or cortical bone in children and adolescents, especially young athletes, have been well described. However, there are no reports in the current English language literature of stress injury affecting the incompletely ossified epiphyseal cartilage. We present four cases of stress related change to the proximal tibial epiphysis (PTE) along with their respective magnetic resonance imaging (MRI) appearances ranging from subtle oedema signal to a pseudo-tumour like appearance within the epiphyseal cartilage. The site and pattern of intra-epiphyseal injury is determined by the type of tissue that is affected, the maturity of the skeleton and the type of forces that are transmitted through the tissue. We demonstrate how an awareness of the morphological spectrum of MRI appearances in intra-epiphyseal stress injury and the ability to identify concomitant signs of stress in other nearby structures can help reduce misdiagnosis, avoid invasive diagnostic procedures like bone biopsy and reassure patients and their families

  10. Simulation of non-resonant internal kink mode with toroidal rotation in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Feng; Liu, J. Y. [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); Fu, G. Y.; Breslau, J. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Tritz, Kevin [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2013-07-15

    Plasmas in spherical and conventional tokamaks, with weakly reversed shear q profile and minimum q above but close to unity, are susceptible to an non-resonant (m,n) = (1,1) internal kink mode. This mode can saturate and persist and can induce a (2,1) seed island for Neoclassical Tearing Mode. [Breslau et al. Nucl. Fusion 51, 063027 (2011)]. The mode can also lead to large energetic particle transport and significant broadening of beam-driven current. Motivated by these important effects, we have carried out extensive nonlinear simulations of the mode with finite toroidal rotation using parameters and profiles of an NTSX plasma with a weakly reversed shear profile. The numerical results show that, at the experimental level, plasma rotation has little effect on either equilibrium or linear stability. However, rotation can significantly influence the nonlinear dynamics of the (1,1) mode and the induced (2,1) magnetic island. The simulation results show that a rotating helical equilibrium is formed and maintained in the nonlinear phase at finite plasma rotation. In contrast, for non-rotating cases, the nonlinear evolution exhibits dynamic oscillations between a quasi-2D state and a helical state. Furthermore, the effects of rotation are found to greatly suppress the (2,1) magnetic island even at a low level.

  11. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    International Nuclear Information System (INIS)

    Karmonik, C.; Benndorf, G.; Klucznik, R.

    2008-01-01

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. ±60 to ±100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  12. Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Gutberlet, Matthias [University of Leipzig - Heart Center, Department of Radiology, Leipzig (Germany); Hindricks, Gerhard; Sommer, Philipp; Hilbert, Sebastian [University of Leipzig - Heart Center, Department of Electrophysiology, Leipzig (Germany); Fleiter, Christian [Helios Klinikum Berlin-Buch, Department of Orthopaedic Surgery, Berlin (Germany); Schnackenburg, Bernhard [Philips Healthcare, Hamburg (Germany); Weiss, Steffen; Krueger, Sascha [Philips Innovative Technologies, Hamburg (Germany); Piorkowski, Christopher; Gaspar, Thomas [University of Dresden - Heart Center, Department of Electrophysiology, Dresden (Germany); Wedan, Steve; Lloyd, Thomas [Imricor Medical Systems, Burnsville, MN (United States)

    2017-05-15

    To evaluate the feasibility of performing comprehensive Cardiac Magnetic resonance (CMR) guided electrophysiological (EP) interventions in a porcine model encompassing left atrial access. After introduction of two femoral sheaths 14 swine (41 ± 3.6 kg) were transferred to a 1.5 T MR scanner. A three-dimensional whole-heart sequence was acquired followed by segmentation and the visualization of all heart chambers using an image-guidance platform. Two MR conditional catheters were inserted. The interventional protocol consisted of intubation of the coronary sinus, activation mapping, transseptal left atrial access (n = 4), generation of ablation lesions and eventually ablation of the atrioventricular (AV) node. For visualization of the catheter tip active tracking was used. Catheter positions were confirmed by passive real-time imaging. Total procedure time was 169 ± 51 minutes. The protocol could be completed in 12 swine. Two swine died from AV-ablation induced ventricular fibrillation. Catheters could be visualized and navigated under active tracking almost exclusively. The position of the catheter tips as visualized by active tracking could reliably be confirmed with passive catheter imaging. Comprehensive CMR-guided EP interventions including left atrial access are feasible in swine using active catheter tracking. (orig.)

  13. Cancer and diverticulitis of the sigmoid colon. Differentiation with computed tomography versus magnetic resonance imaging - Preliminary experiences

    International Nuclear Information System (INIS)

    Oeistaemoe, Emma; Hjern, Fredrik; Abraham-Nordling, Mirna; Blomqvist, Lennart; Von Heijne, Anders

    2013-01-01

    Background: Both colon cancer and diverticular disease are common in the Western world. A challenge when patients present with clinical findings is that both diseases can present with symptoms that may mimic the other. Purpose: To determine whether magnetic resonance imaging (MRI) could be helpful to differentiate between diverticulitis and cancer of the sigmoid colon compared to the differentiation offered by evaluation of multidetector computed tomography (CT) in a clinical situation. Material and Methods: Thirty patients were consecutively included. Fifteen patients were under work-up for a recently diagnosed sigmoid cancer and 15 patients had recently been treated in hospital due to first-time acute sigmoid diverticulitis. All patients underwent CT, T2- weighted MRI and diffusion-weighted MRI. Anonymized examinations were retrospectively presented in random order to one experienced radiologist. Results: With contrast-enhanced CT, the sensitivity and specificity for diagnosis of cancer and diverticulitis were 66.7% (10/15) and 93.3% (14/15), respectively. Using T2-weighted and diffusion-weighted MR images, the sensitivity and specificity for diagnosis of cancer and diverticulitis were 100% (14/14) and 100% (14/14), respectively. Conclusion: MRI provides information that may contribute to improve the differentiation between sigmoid cancer and diverticulitis that is offered by CT. These encouraging results need to be confirmed in a larger study

  14. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    International Nuclear Information System (INIS)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto; Habib, Fortunee I.; Tomei, Ernesto; Paolantonio, Pasquale; Laghi, Andrea

    2006-01-01

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  15. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences, Rome (Italy); Habib, Fortunee I.; Tomei, Ernesto [University of Rome ' ' La Sapienza' ' , Division of Gastroenterology, Rome (Italy); Paolantonio, Pasquale; Laghi, Andrea [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences - Polo Didattico Pontino I.C.O.T, Rome (Italy)

    2006-09-15

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  16. Application of a protocol for magnetic resonance spectroscopy of adrenal glands: an experiment with over 100 cases.

    Science.gov (United States)

    Melo, Homero José de Farias E; Goldman, Suzan M; Szejnfeld, Jacob; Faria, Juliano F; Huayllas, Martha K P; Andreoni, Cássio; Kater, Cláudio E

    2014-01-01

    To evaluate a protocol for two-dimensional (2D) hydrogen proton (1H) magnetic resonance spectroscopy (MRS) (Siemens Medical Systems; Erlangen, Germany) in the detection of adrenal nodules and differentiation between benign and malignant masses (adenomas, pheochromocytomas, carcinomas and metastases). A total of 118 patients (36 men; 82 women) (mean age: 57.3 ± 13.3 years) presenting with 138 adrenal nodules/masses were prospectively assessed. A multivoxel system was utilized with a 2D point-resolved spectroscopy/chemical shift imaging sequence. The following ratios were calculated: choline (Cho)/creatine (Cr), 4.0-4.3/Cr, lipid (Lip)/Cr, Cho/Lip and lactate (Lac)/Cr. 2D-1H-MRS was successful in 123 (89.13%) lesions. Sensitivity and specificity values observed for the ratios and cutoff points were the following: Cho/Cr ≥ 1.2, 100% sensitivity, 98.2% specificity (differences between adenomas/pheochromocytomas and carcinomas/ metastases); 4.0-4.3 ppm/Cr ≥ 1.5, 92.3% sensitivity, 96.9% specificity (differences between carcinomas/pheochromocytomas and adenomas/metastases); Lac/Cr ≤ -7.449, 90.9% sensitivity and 77.8% specificity (differences between pheochromocytomas and carcinomas/adenomas). Information provided by 2D-1H-MRS were effective and allowed for the differentiation between adrenal masses and nodules in most cases of lesions with > 1.0 cm in diameter.

  17. Sensitivity and Specificity of Magnetic Resonance Cholangiopancreatography versus Endoscopic Ultrasonography against Endoscopic Retrograde Cholangiopancreatography in Diagnosing Choledocholithiasis: The Indonesian Experience

    Directory of Open Access Journals (Sweden)

    Dadang Makmun

    2017-09-01

    Full Text Available Background/Aims Biliary stone disease is one of the most common conditions leading to hospitalization. In addition to endoscopic retrograde cholangiopancreatography (ERCP, endoscopic ultrasonography (EUS and magnetic resonance cholangiopancreatography (MRCP are required in diagnosing choledocholithiasis. This study aimed to compare the sensitivity and specificity of EUS and MRCP against ERCP in diagnosing choledocholithiasis. Methods This retrospective study was conducted after prospective collection of data involving 62 suspected choledocholithiasis patients who underwent ERCP from June 2013 to August 2014. Patients were divided into two groups. The first group (31 patients underwent EUS and the second group (31 patients underwent MRCP. Then, ERCP was performed in both groups. Sensitivity, specificity, and diagnostic accuracy of EUS and MRCP were determined by comparing them to ERCP, which is the gold standard. Results The male to female ratio was 3:2. The mean ages were 47.25 years in the first group and 52.9 years in the second group. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for EUS were 96%, 57%, 87%, 88%, and 80% respectively, and for MRCP were 81%, 40%, 68%, 74%, and 50%, respectively. Conclusions EUS is a better diagnostic tool than MRCP for diagnosing choledocholithiasis.

  18. Drying of carrot slices in a triple pass solar dryer

    Directory of Open Access Journals (Sweden)

    Seshachalam Kesavan

    2017-01-01

    Full Text Available An indirect triple pass forced convection solar dryer was developed and its performance was evaluated for drying of carrot slices. The drying experiments were carried out under the meteorological conditions of Coimbatore city in India during the year 2016. The experimental set-up consists of a blower, triple pass packed bed air collector (using sand with wire mesh absorber plate, and a drying chamber. The air mass flow rate was optimized to 0.062 kg/s. The initial moisture content of the carrot slices was reduced from 87.5% (on wet basis to the final moisture content of 10% (wet basis in 6 h duration. The thin layer drying characteristics were analyzed using twelve mathematical models available in open literature. The results showed that the pick-up efficiency of the dryer was varied in the range between 14 and 43% with an average air collector thermal efficiency of 44% during the experimentation. The drying characteristics of carrot slices was predicted with good degree of accuracy using Wang and Singh drying model.

  19. Microwave measurement test results of circular waveguide components for electron cyclotron resonant heating (ECRH) of the Tandem Mirror Experiment-Upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Williams, C.W.; Rubert, R.R.; Coffield, F.E.; Felker, B.; Stallard, B.W.; Taska, J.

    1983-01-01

    Development of high-power components for electron cyclotron resonant heating (ECRH) applications requires extensive testing. In this paper we describe the high-power testing of various circular waveguide components designed for application on the Tandem Mirror Experiment-Upgrade (TMX-U). These include a 2.5-in. vacuum valve, polarizing reflectors, directional couplers, mode converters, and flexible waveguides. All of these components were tested to 200 kW power level with 40-ms pulses. Cold tests were used to determine field distribution. The techniques used in these tests are illustrated. The new high-power test facility at Lawrence Livermore National Laboratory (LLNL) is described and test procedures are discussed. We discuss the following test results: efficiency at high power of mode converters, comparison of high power vs low power for waveguide components, and full power tests of the waveguide system. We also explain the reasons behind selection of these systems for use on TMX-U

  20. The value of magnetic resonance imaging in the early diagnosis of Creutzfeldt-Jakob disease – own experience

    International Nuclear Information System (INIS)

    Bekiesińska-Figatowska, Monika; Kuczyńska-Zardzewiały, Arleta; Pomianowska, Barbara; Kajdana, Katarzyna; Szpak, Grażyna M.; Iwanowska, Beata; Mądzik, Jarosław

    2012-01-01

    Creutzfeldt-Jakob disease (CJD) is a rare progressive neurodegenerative disorder, caused by the deposition of the pathological isoform of prion protein PrPsc in the central nervous system. The classic triad of symptoms consists of: rapidly progressive dementia, myoclonus and typical electroencephalographic findings (intermittent rhythmic delta activity and periodic sharp wave complexes). Detection of 14-3-3 protein in the cerebrospinal fluid plays an important diagnostic role as well. Magnetic resonance (MR) images of the brain have been recently incorporated into the diagnostic criteria of sporadic Creutzfeldt-Jakob disease. MR examinations were performed in a 65-year-old man and a 54-year-old woman with delusional disorder and cognitive dysfunction, respectively. Diffusion restriction (hyperintense signal in DWI) was shown in the cortex of the left parietal and occipital lobe in the first patient and symmetrically in the cortex of both cerebral hemispheres except for precentral gyri in the second one. In both cases, the first examinations were misread, with the suspicion of ischemic infarcts as the first differential diagnosis. Consultations and subsequent MR examinations in which lesions in subcortical nuclei appeared allowed for a diagnosis of probable CJD. In the first case it was confirmed by clinical picture, EEG and finally – autopsy. In the second case, EEG was not typical for CJD but the clinical course of the disease confirmed that diagnosis. The authors present the cases of two patients with characteristic MR images that allowed early diagnosis of probable Creutzfeldt-Jakob disease before the characteristic clinical picture appeared. Early diagnosis is nowadays important for the prevention of disease transmission and in the future – hopefully – for early treatment

  1. Detection of cerebrospinal fluid leakage: initial experience with three-dimensional fast spin-echo magnetic resonance myelography.

    Science.gov (United States)

    Tomoda, Y; Korogi, Y; Aoki, T; Morioka, T; Takahashi, H; Ohno, M; Takeshita, I

    2008-03-01

    The pathogenesis of cerebrospinal fluid (CSF) hypovolemia is supposed to be caused by CSF leakage through small dural defects. To compare source three-dimensional (3D) fast spin-echo (FSE) images of magnetic resonance (MR) myelography with radionuclide cisternography findings, and to evaluate the feasibility of MR myelography in the detection of CSF leakage. A total of 67 patients who were clinically suspected of CSF hypovolemia underwent indium-111 radionuclide cisternography, and 27 of those who had direct findings of CSF leakage were selected for evaluation. MR myelography with 3D FSE sequences (TR/TE 6000/203 ms) was performed at the lumbar spine for all patients. We evaluated source images and maximum intensity projection (MIP) images of MR myelography, and the findings were correlated with radionuclide cisternography findings. MR myelography of five healthy volunteers was used as a reference. The MR visibility of the CSF leakage was graded as definite (leakage clearly visible), possible (leakage poorly seen), or absent (not shown). CSF leakage was identified with source 3D FSE images in 22 (81.5%) of 27 patients. Of the 22 patients, 16 were graded as definite and six were graded as possible. For the definite cases, 3D FSE images clearly showed the extent of the leaked CSF in the paraspinal structures. In the remaining five patients with absent findings, radionuclide cisternography showed only slight radionuclide activity out of the arachnoid space. Source 3D FSE images of MR myelography seem useful in the detection of CSF leakage. Invasive radionuclide cisternography may be reserved for equivocal cases only.

  2. Postoperative Neurosurgical Infection Rates After Shared-Resource Intraoperative Magnetic Resonance Imaging: A Single-Center Experience with 195 Cases.

    Science.gov (United States)

    Dinevski, Nikolaj; Sarnthein, Johannes; Vasella, Flavio; Fierstra, Jorn; Pangalu, Athina; Holzmann, David; Regli, Luca; Bozinov, Oliver

    2017-07-01

    To determine the rate of surgical-site infections (SSI) in neurosurgical procedures involving a shared-resource intraoperative magnetic resonance imaging (ioMRI) scanner at a single institution derived from a prospective clinical quality management database. All consecutive neurosurgical procedures that were performed with a high-field, 2-room ioMRI between April 2013 and June 2016 were included (N = 195; 109 craniotomies and 86 endoscopic transsphenoidal procedures). The incidence of SSIs within 3 months after surgery was assessed for both operative groups (craniotomies vs. transsphenoidal approach). Of the 109 craniotomies, 6 patients developed an SSI (5.5%, 95% confidence interval [CI] 1.2-9.8%), including 1 superficial SSI, 2 cases of bone flap osteitis, 1 intracranial abscess, and 2 cases of meningitis/ventriculitis. Wound revision surgery due to infection was necessary in 4 patients (4%). Of the 86 transsphenoidal skull base surgeries, 6 patients (7.0%, 95% CI 1.5-12.4%) developed an infection, including 2 non-central nervous system intranasal SSIs (3%) and 4 cases of meningitis (5%). Logistic regression analysis revealed that the likelihood of infection significantly decreased with the number of operations in the new operational setting (odds ratio 0.982, 95% CI 0.969-0.995, P = 0.008). The use of a shared-resource ioMRI in neurosurgery did not demonstrate increased rates of infection compared with the current available literature. The likelihood of infection decreased with the accumulating number of operations, underlining the importance of surgical staff training after the introduction of a shared-resource ioMRI. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. On Spectral Triples in Quantum Gravity I

    DEFF Research Database (Denmark)

    Aastrup, Johannes; M. Grimstrup, Jesper; Nest, Ryszard

    2009-01-01

    This paper establishes a link between Noncommutative Geometry and canonical quantum gravity. A semi-finite spectral triple over a space of connections is presented. The triple involves an algebra of holonomy loops and a Dirac type operator which resembles a global functional derivation operator....... The interaction between the Dirac operator and the algebra reproduces the Poisson structure of General Relativity. Moreover, the associated Hilbert space corresponds, up to a discrete symmetry group, to the Hilbert space of diffeomorphism invariant states known from Loop Quantum Gravity. Correspondingly......, the square of the Dirac operator has, in terms of canonical quantum gravity, the form of a global area-squared operator. Furthermore, the spectral action resembles a partition function of Quantum Gravity. The construction is background independent and is based on an inductive system of triangulations...

  4. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. WDVV equation and triple-product relation

    International Nuclear Information System (INIS)

    Shigechi, Keiichi; Wadati, Miki; Wang Ning

    2005-01-01

    We study the relation between the WDVV equations and the τ-function of the noncommutative KP (NCKP) hierarchy. WDVV-like equations (Hirota triple-product relation) in the noncommutative context appear as a consequence of the nontrivial equation for τ-function of the NC KP hierarchy, while the prepotential in the Seiberg-Witten (SW) theory has been identified to the τ-function of the Whitham hierarchy. We show that the spectral curve for the SW theory is the same as the Toda-chain hierarchy. We also show explicitly that Whitham hierarchy includes commutative Toda/KP hierarchy. Further, we comment on the origin of the Hirota triple-product relation in the context of the SW theory

  6. NMR experiments for resonance assignments of 13C, 15N doubly-labeled flexible polypeptides: Application to the human prion protein hPrP(23-230)

    International Nuclear Information System (INIS)

    Liu Aizhuo; Riek, Roland; Wider, Gerhard; Schroetter, Christine von; Zahn, Ralph; Wuethrich, Kurt

    2000-01-01

    A combination of three heteronuclear three-dimensional NMR experiments tailored for sequential resonance assignments in uniformly 15 N, 13 C-labeled flexible polypeptide chains is described. The 3D (H)N(CO-TOCSY)NH, 3D (H)CA(CO-TOCSY)NH and 3D (H)CBCA(CO-TOCSY)NH schemes make use of the favorable 15 N chemical shift dispersion in unfolded polypeptides, exploit the slow transverse 15 N relaxation rates of unfolded polypeptides in high resolution constant-time [ 1 H, 15 N]-correlation experiments, and use carbonyl carbon homonuclear isotropic mixing to transfer magnetization sequentially along the amino acid sequence. Practical applications are demonstrated with the 100-residue flexible tail of the recombinant human prion protein, making use of spectral resolution up to 0.6 Hz in the 15 N dimension, simultaneous correlation with the two adjacent amino acid residues to overcome problems associated with spectral overlap, and the potential of the presently described experiments to establish nearest-neighbor correlations across proline residues in the amino acid sequence

  7. Resolution of a triple axis spectrometer

    DEFF Research Database (Denmark)

    Nielsen, Mourits; Bjerrum Møller, Hans

    1969-01-01

    A new method for obtaining the resolution function for a triple-axis neutron spectrometer is described, involving a combination of direct measurement and analytical calculation. All factors which contribute to the finite resolution of the instrument may be taken into account, and Gaussian...... or experimentally determined probability distributions may be used. The application to the study of the dispersion relation for excitations in a crystal is outlined...

  8. Triple collinear emissions in parton showers

    Energy Technology Data Exchange (ETDEWEB)

    Höche, Stefan; Prestel, Stefan

    2017-10-01

    A framework to include triple collinear splitting functions into parton showers is presented, and the implementation of flavor-changing NLO splitting kernels is discussed as a first application. The correspondence between the Monte-Carlo integration and the analytic computation of NLO DGLAP evolution kernels is made explicit for both timelike and spacelike parton evolution. Numerical simulation results are obtained with two independent implementations of the new algorithm, using the two independent event generation frameworks Pythia and Sherpa.

  9. Resonant laser power build-up in ALPS. A 'light-shining-through-walls' experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ehret, Klaus; Ghazaryan, Samvel [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Frede, Maik [Laser Zentrum Hannover e.V. (DE)] (and others)

    2009-05-15

    The ALPS collaboration runs a light-shining-through-walls (LSW) experiment to search for photon oscillations into weakly interacting sub-eV particles (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run. (orig.)

  10. A Tulczyjew triple for classical fields

    International Nuclear Information System (INIS)

    Grabowska, Katarzyna

    2012-01-01

    The geometrical structure known as the Tulczyjew triple has proved to be very useful in describing mechanical systems, even those with singular Lagrangians or subject to constraints. Starting from basic concepts of the variational calculus, we construct the Tulczyjew triple for first-order field theory. The important feature of our approach is that we do not postulate ad hoc the ingredients of the theory, but obtain them as unavoidable consequences of the variational calculus. This picture of field theory is covariant and complete, containing not only the Lagrangian formalism and Euler–Lagrange equations but also the phase space, the phase dynamics and the Hamiltonian formalism. Since the configuration space turns out to be an affine bundle, we have to use affine geometry, in particular the notion of the affine duality. In our formulation, the two maps α and β which constitute the Tulczyjew triple are morphisms of double structures of affine-vector bundles. We also discuss the Legendre transformation, i.e. the transition between the Lagrangian and the Hamiltonian formulation of the first-order field theory. (paper)

  11. Chloral hydrate in pediatric magnetic resonance imaging: evaluation of a 10-year sedation experience administered by radiologists

    International Nuclear Information System (INIS)

    Delgado, Jorge; Toro, Rodrigo; Rascovsky, Simon; Arango, Andres; Angel, Gabriel J.; Calvo, Victor; Delgado, Jorge A.

    2015-01-01

    Chloral hydrate is a sedative that has been used for magnetic resonance imaging (MRI). To evaluate the use, effectiveness and safety of chloral hydrate administered by radiologists for the sedation of children who require MRI procedures. We retrospectively reviewed the clinical charts for all patients ages 0 - 10 years old who underwent sedation with chloral hydrate for MRI from January 2000 to December 2010. Demographic factors, dose information, indication for MRI, therapeutic failures and adverse reactions to the drug were reviewed. One thousand, seven hundred and three children (946 males, 757 females) with a median age of 2.5 years (range: 4 days - 9.91 years) received chloral hydrate. Moderate to deep sedation was achieved in 1,618/1,703 (95%) of the patients, 35/1,703 (2.1%) of the patients failed to achieve moderate to deep sedation, and 47/1,703 (2.8%) of the patients woke up during MRI examination. Adverse reactions were present in 31/1,703 (1.8%) of the patients. Three severe adverse reactions occurred (0.18%). A single dose of chloral hydrate (40-60 mg/kg) was administered to 1,477/1,703 patients (86.7%). An additional dose of chloral hydrate (10-20 mg/kg), given 15 min after the first dose or when the patient woke up during the MRI examination, was required in 226/1,703 patients (13.3%). The likelihood of requiring an additional dose in children older than 2 years was 2.2 times the likelihood compared to children younger than 2 years (OR = 2.2 [95%CI: 1.6-3.0]). The use of a reduced dose (<50 mg/kg) was not associated with a higher therapeutic failure rate (OR = 1.04 [95%CI 0.57-1.89]). Chloral hydrate is an appropriate sedation option for pediatric patients in MRI services when strict patient selection criteria are met. The use of a reduced dose does not affect the effectiveness of sedation. The lack of data regarding the presence of transient oxygen desaturation, the time to induce sedation and the exact duration of sedation are limitations of this

  12. Magnetic resonance imaging-detected tumor response for locally advanced rectal cancer predicts survival outcomes: MERCURY experience.

    Science.gov (United States)

    Patel, Uday B; Taylor, Fiona; Blomqvist, Lennart; George, Christopher; Evans, Hywel; Tekkis, Paris; Quirke, Philip; Sebag-Montefiore, David; Moran, Brendan; Heald, Richard; Guthrie, Ashley; Bees, Nicola; Swift, Ian; Pennert, Kjell; Brown, Gina

    2011-10-01

    To assess magnetic resonance imaging (MRI) and pathologic staging after neoadjuvant therapy for rectal cancer in a prospectively enrolled, multicenter study. In a prospective cohort study, 111 patients who had rectal cancer treated by neoadjuvant therapy were assessed for response by MRI and pathology staging by T, N and circumferential resection margin (CRM) status. Tumor regression grade (TRG) was also assessed by MRI. Overall survival (OS) was estimated by using the Kaplan-Meier product-limit method, and Cox proportional hazards models were used to determine associations between staging of good and poor responders on MRI or pathology and survival outcomes after controlling for patient characteristics. On multivariate analysis, the MRI-assessed TRG (mrTRG) hazard ratios (HRs) were independently significant for survival (HR, 4.40; 95% CI, 1.65 to 11.7) and disease-free survival (DFS; HR, 3.28; 95% CI, 1.22 to 8.80). Five-year survival for poor mrTRG was 27% versus 72% (P = .001), and DFS for poor mrTRG was 31% versus 64% (P = .007). Preoperative MRI-predicted CRM independently predicted local recurrence (LR; HR, 4.25; 95% CI, 1.45 to 12.51). Five-year survival for poor post-treatment pathologic T stage (ypT) was 39% versus 76% (P = .001); DFS for the same was 38% versus 84% (P = .001); and LR for the same was 27% versus 6% (P = .018). The 5-year survival for involved pCRM was 30% versus 59% (P = .001); DFS, 28 versus 62% (P = .02); and LR, 56% versus 10% (P = .001). Pathology node status did not predict outcomes. MRI assessment of TRG and CRM are imaging markers that predict survival outcomes for good and poor responders and provide an opportunity for the multidisciplinary team to offer additional treatment options before planning definitive surgery. Postoperative histopathology assessment of ypT and CRM but not post-treatment N status were important postsurgical predictors of outcome.

  13. Chloral hydrate in pediatric magnetic resonance imaging: evaluation of a 10-year sedation experience administered by radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, Jorge; Toro, Rodrigo; Rascovsky, Simon; Arango, Andres; Angel, Gabriel J.; Calvo, Victor; Delgado, Jorge A. [Fundacion Instituto de Alta Tecnologia Medica, Department of Radiology, Medellin (Colombia)

    2014-08-21

    Chloral hydrate is a sedative that has been used for magnetic resonance imaging (MRI). To evaluate the use, effectiveness and safety of chloral hydrate administered by radiologists for the sedation of children who require MRI procedures. We retrospectively reviewed the clinical charts for all patients ages 0 - 10 years old who underwent sedation with chloral hydrate for MRI from January 2000 to December 2010. Demographic factors, dose information, indication for MRI, therapeutic failures and adverse reactions to the drug were reviewed. One thousand, seven hundred and three children (946 males, 757 females) with a median age of 2.5 years (range: 4 days - 9.91 years) received chloral hydrate. Moderate to deep sedation was achieved in 1,618/1,703 (95%) of the patients, 35/1,703 (2.1%) of the patients failed to achieve moderate to deep sedation, and 47/1,703 (2.8%) of the patients woke up during MRI examination. Adverse reactions were present in 31/1,703 (1.8%) of the patients. Three severe adverse reactions occurred (0.18%). A single dose of chloral hydrate (40-60 mg/kg) was administered to 1,477/1,703 patients (86.7%). An additional dose of chloral hydrate (10-20 mg/kg), given 15 min after the first dose or when the patient woke up during the MRI examination, was required in 226/1,703 patients (13.3%). The likelihood of requiring an additional dose in children older than 2 years was 2.2 times the likelihood compared to children younger than 2 years (OR = 2.2 [95%CI: 1.6-3.0]). The use of a reduced dose (<50 mg/kg) was not associated with a higher therapeutic failure rate (OR = 1.04 [95%CI 0.57-1.89]). Chloral hydrate is an appropriate sedation option for pediatric patients in MRI services when strict patient selection criteria are met. The use of a reduced dose does not affect the effectiveness of sedation. The lack of data regarding the presence of transient oxygen desaturation, the time to induce sedation and the exact duration of sedation are limitations of this

  14. [Magnetic resonance guided focused ultrasound surgery for pain palliation of bone metastases: early experience of clinical application in China].

    Science.gov (United States)

    Gu, Jianjun; Wang, Han; Tang, Na; Hua, Yingqi; Yang, Haiyan; Qiu, Yimin; Ge, Renbin; Zhou, Ying; Wang, Wenwen; Zhang, Guixiang

    2015-11-03

    To evaluate the safety and efficacy of magnetic resonance guided focused ultrasound surgery (MRgFUS) in treatment for pain palliation of bone metastases. Eighty-one patients of painful bone metastases were volunteered to screen for this study in Shanghai General Hospital from June 2014 to February 2015. Twenty-three patients among them were treated by MRgFUS, who was more than 18-years old, having the ability to fully understand the informed consent of the research, suffering with pain of numeric rating scale (NRS) ≥ 4, non-received radiotherapy or chemotherapy for pain palliation of bone metastases in the past two weeks. The NRS, the standard question of Brief Pain Inventory (BPI-QoL), and the standard question of Europe Organization for Research and Treatment of Cancer Quality of Life Questionnaire- Bone Metastases 22 (EORTC QLQ-BM22) were respectively recorded before and 1-week, 1-month, 3-month after the treatment. The related adverse events of MRgFUS were observed and recorded in 3 months after the treatment as well. (1)Twenty-three metastatic bone tumor lesions of 23 patients were treated by MRgFUS, the treatment data was as follows: the mean treatment time was (88 ± 33) minutes, the mean sonication number was 13 ± 8. (2) Adverse events included: pain in therapy area 3/23, which spontaneous relieving within one week; numbness in lower limb (1/23), which relieved after physiotherapy. (3) The NRS of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 6.0 ± 1.5, 3.7 ± 1.7,3.1 ± 2.0, and 2.2 ± 1.0,which significantly decreased after the treatment (P<0.01). (4) The BPI-QoL score of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 39 ± 16, 27 ± 18, 26 ± 18, and 21 ± 18, which significantly decreased after the treatment (P<0.01). (5) The EORTC QLQ-BM22 score of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 52 ± 13, 44 ± 12, 42 ± 12, and 39

  15. Multiphoton resonances

    International Nuclear Information System (INIS)

    Shore, B.W.

    1977-01-01

    The long-time average of level populations in a coherently-excited anharmonic sequence of energy levels (e.g., an anharmonic oscillator) exhibits sharp resonances as a function of laser frequency. For simple linearly-increasing anharmonicity, each resonance is a superposition of various multiphoton resonances (e.g., a superposition of 3, 5, 7, . . . photon resonances), each having its own characteristic width predictable from perturbation theory

  16. Fano–Kondo Effect in a Triple Quantum Dots Coupled to Ferromagnetic Leads

    International Nuclear Information System (INIS)

    Ai-Hua, Bi; Shao-Quan, Wu; Tao, Hou; Wei-Li, Sun

    2008-01-01

    Using the Keldysh nonequilibrium Green function and equation-of-motion technique, we have qualitatively studied the spin-dependent transport of a triple-QD system in the Kondo regime. It is shown that the Kondo resonance and Fano interference coexist, and in this system the Fano–Kondo effect shows dip behaviours richer than that in the T-shaped QDs. The interdot coupling, the energy level of the side coupled QDs and the spin polarization strength greatly influence the DOS of the central quantum dot QD 0 . Either the increase of the coupling strength between the two QDs or that of the energy levels of the side coupled QDs enhances the Kondo resonance. Especially, the Kondo resonance is strengthened greatly when the side dot energy is fixed at the Fermi energy. Meanwhile, the Kondo resonance splits for the spin-up and spin-down configurations due to the polarization: the down-spin resonance is enhanced, and the up-spin resonance is suppressed. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  17. Out-and-back {sup 13}C-{sup 13}C scalar transfers in protein resonance assignment by proton-detected solid-state NMR under ultra-fast MAS

    Energy Technology Data Exchange (ETDEWEB)

    Barbet-Massin, Emeline; Pell, Andrew J. [University of Lyon, CNRS/ENS Lyon/UCB Lyon 1, Centre de RMN a Tres Hauts Champs (France); Jaudzems, Kristaps [Latvian Institute of Organic Synthesis (Latvia); Franks, W. Trent; Retel, Joren S. [Leibniz-Institut fuer Molekulare Pharmakologie (Germany); Kotelovica, Svetlana; Akopjana, Inara; Tars, Kaspars [Biomedical Research and Study Center (Latvia); Emsley, Lyndon [University of Lyon, CNRS/ENS Lyon/UCB Lyon 1, Centre de RMN a Tres Hauts Champs (France); Oschkinat, Hartmut [Leibniz-Institut fuer Molekulare Pharmakologie (Germany); Lesage, Anne; Pintacuda, Guido, E-mail: guido.pintacuda@ens-lyon.fr [University of Lyon, CNRS/ENS Lyon/UCB Lyon 1, Centre de RMN a Tres Hauts Champs (France)

    2013-08-15

    We present here {sup 1}H-detected triple-resonance H/N/C experiments that incorporate CO-CA and CA-CB out-and-back scalar-transfer blocks optimized for robust resonance assignment in biosolids under ultra-fast magic-angle spinning (MAS). The first experiment, (H)(CO)CA(CO)NH, yields {sup 1}H-detected inter-residue correlations, in which we record the chemical shifts of the CA spins in the first indirect dimension while during the scalar-transfer delays the coherences are present only on the longer-lived CO spins. The second experiment, (H)(CA)CB(CA)NH, correlates the side-chain CB chemical shifts with the NH of the same residue. These high sensitivity experiments are demonstrated on both fully-protonated and 100 %-H{sup N} back-protonated perdeuterated microcrystalline samples of Acinetobacter phage 205 (AP205) capsids at 60 kHz MAS.

  18. Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.

    Science.gov (United States)

    Noureddine, Yacine; Bitz, Andreas K; Ladd, Mark E; Thürling, Markus; Ladd, Susanne C; Schaefers, Gregor; Kraff, Oliver

    2015-12-01

    Over the last decade, the number of clinical MRI studies at 7 T has increased dramatically. Since only limited information about the safety of implants/tattoos is available at 7 T, many centers either conservatively exclude all subjects with implants/tattoos or have started to perform dedicated tests for selected implants. This work presents our experience in imaging volunteers with implants/tattoos at 7 T over the last seven and a half years. 1796 questionnaires were analyzed retrospectively to identify subjects with implants/tattoos imaged at 7 T. For a total of 230 subjects, the type of local transmit/receive RF coil used for examination, imaging sequences, acquisition time, and the type of implants/tattoos and their location with respect to the field of view were documented. These subjects had undergone examination after careful consideration by an internal safety panel consisting of three experts in MR safety and physics. None of the subjects reported sensations of heat or force before, during, or after the examination. None expressed any discomfort related to implants/tattoos. Artifacts were reported in 52% of subjects with dental implants; all artifacts were restricted to the mouth area and did not affect image quality in the brain parenchyma. Our initial experience at 7 T indicates that a strict rejection of subjects with tattoos and/or implants is not justified. Imaging can be conditionally performed in carefully selected subjects after collection of substantial safety information and evaluation of the detailed exposure scenario (RF coil/type and position of implant). Among the assessed subjects with tattoos, no side effects from the exposure to 7 T MRI were reported.

  19. A pilot study using magnetic resonance imaging to determine the pattern of muscle group recruitment by rowers with different levels of experience

    International Nuclear Information System (INIS)

    Green, R.A.R.; Wilson, D.J.

    2000-01-01

    Objective. To determine whether it was possible using magnetic resonance imaging (MRI) to define the pattern of muscle recruitment in a specific sport (rowing) and to see whether there were differences in this pattern between athletes of different experience.Design and method. It has been shown that during vigorous exercise the water content of muscle increases transiently. This can be observed using MRI, where the prolonged T2 relaxation time of muscle can be demonstrated. In this study we have exploited the increase in signal seen in exercised muscle on short TI inversion recovery (STIR) sequences, to show how rowers of different experience use different muscle groups.Results. We have shown that trained athletes recruit selected muscle groups to carry out a given task, which they carry out more efficiently than untrained or less experienced athletes.Conclusion. We have provided the basis of potential research to refine training methods, in order to develop specific muscle groups in athletes, in the hope of achieving a higher level of performance at an earlier stage in their training. We have also defined a technique that may be of clinical value in cases of muscle dysfunction. (orig.)

  20. Multilayer Antireflection Coating for Triple Junction Solar Cells

    International Nuclear Information System (INIS)

    Zhan Feng; Wang Hai-Li; He Ji-Fang; Wang Juan; Huang She-Song; Ni Hi-Qiao; Niu Zhi-Chuan

    2011-01-01

    According to the theory of optical films, we simulate the reflectivity of antireflection coatings (ARCs) for solar cells of Ga 0.5 In 0.5 P/GaAs/Ge based on an optical transfer matrix. In order to provide sufficient consideration of the refractive index dispersion effect of multilayer ARCs, we use multi-dimensional matrix data for reliable simulation. After the reflection curves are obtained, the effective average reflectance R e is introduced to optimize the film system by minimizing R e . Optimization of single layer (Al 2 O 3 ), double layer (MgF 2 /ZnS) and triple layer (MgF 2 /Al 2 O 3 /ZnS) ARCs is realized by using this method for space and terrestrial applications. Effects of these ARCs are compared after optimization. These theoretical parameters can be used to guide experiments. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  1. Small angle neutron scattering using a triple axis spectrometer

    International Nuclear Information System (INIS)

    Ahmed, F.U.; Goyal, P.S.; Kamal, L.; Yunus, S.M.; Datta, T.K.; Rahman, M.O.; Azad, A.K.; Begum, S.; Zakaria, A.K.

    1994-01-01

    SANS techniques has been developed on a triple axis neutron spectrometer at TRIGA Mark II (3 MW) research reactor, AERE, Savar, Dhaka, Bangladesh. Double crystal (with very small mosaic spread ∼ 1 min.) diffraction known as Bonse and Hart's method has been employed. Such a device is a useful tool for small angle scattering in the Q range between 10 -5 and 10 -1 Angstroms -1 and for real time experiments at short time scales. Therefore, large objects and large distance interparticle correlations can be easily investigated. The results of SANS' measurements using alumina (A1 2 0 3 ) sample are presented. The radius of gyration has been determined and the data has been fitted to the scattering function of a sphere. 9 refs., 6 figs.,

  2. Gastric Metastasis of Triple Negative Invasive Lobular Carcinoma.

    Science.gov (United States)

    Geredeli, Caglayan; Dogru, Osman; Omeroglu, Ethem; Yilmaz, Farise; Cicekci, Faruk

    2015-05-05

    Invasive lobular carcinomas are the second most common type (5% to 15%) of invasive breast carcinomas. The most frequent sites of breast cancer metastasis are the local and distant lymph nodes, brain, lung, liver, and bones; metastasis to the gastrointestinal system, especially to the stomach, is rare. When a mass is detected in an unusual place in a patient with invasive lobular carcinoma, it should be kept in mind that such a mass may be either a second primary carcinoma or the metastasis of an invasive lobular carcinoma. In this report, we present a case of gastric metastasis from triple-negative invasive lobular breast cancer. It is important to make an accurate diagnosis by distinguishing gastric metastasis from breast cancer in order to select the best initial treatment for systemic diseases of breast cancer. Considering our case, healthcare professionals should take into account that cases with invasive lobular breast cancer may experience unusual metastases.

  3. Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    Science.gov (United States)

    van Hoof, Stefan J; Granton, Patrick V; Landry, Guillaume; Podesta, Mark; Verhaegen, Frank

    2012-07-07

    A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (pre-IR) film scan, using EBT2 film and kilo- and megavoltage photon beams up to 10 Gy. When considering regions of interest averaged doses, the triple-channel method and both single-channel methods produced equivalent results. Absolute dose discrepancies between the triple-channel method, both single-channel methods and the treatment planning system calculated dose values, were no larger than 5 cGy for dose levels up to 2.2 Gy. Signal to noise in triple-channel dose images was found to be similar to signal to noise in single-channel dose images. The accuracy of resulting dose images from the triple- and single-channel methods with inclusion of pre-IR film scan was found to be similar. Results of a comparison of EBT2 data from a kilovoltage depth dose experiment to corresponding Monte Carlo depth dose data produced dose discrepancies of 9.5 ± 12 cGy and 7.6 ± 6 cGy for the single-channel method with inclusion of a pre-IR film scan and the triple-channel method, respectively. EBT2 showed to be energy sensitive at low kilovoltage energies with response differences of 11.9% and 15.6% in the red channel at 2 Gy between 50-225 kVp and 80-225 kVp photon spectra, respectively. We observed that the triple-channel method resulted in non-uniformity corrections of ±1% and consistency values of 0-3 cGy for the batches and dose levels studied. Results of this study indicate that the triple-channel radiochromic film read-out method performs at least as well as the single-channel method with inclusion of a pre-IR film scan, reduces film non-uniformity and saves time with elimination of a pre-IR film scan.

  4. Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2

    International Nuclear Information System (INIS)

    Van Hoof, Stefan J; Granton, Patrick V; Landry, Guillaume; Podesta, Mark; Verhaegen, Frank

    2012-01-01

    A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (pre-IR) film scan, using EBT2 film and kilo- and megavoltage photon beams up to 10 Gy. When considering regions of interest averaged doses, the triple-channel method and both single-channel methods produced equivalent results. Absolute dose discrepancies between the triple-channel method, both single-channel methods and the treatment planning system calculated dose values, were no larger than 5 cGy for dose levels up to 2.2 Gy. Signal to noise in triple-channel dose images was found to be similar to signal to noise in single-channel dose images. The accuracy of resulting dose images from the triple- and single-channel methods with inclusion of pre-IR film scan was found to be similar. Results of a comparison of EBT2 data from a kilovoltage depth dose experiment to corresponding Monte Carlo depth dose data produced dose discrepancies of 9.5 ± 12 cGy and 7.6 ± 6 cGy for the single-channel method with inclusion of a pre-IR film scan and the triple-channel method, respectively. EBT2 showed to be energy sensitive at low kilovoltage energies with response differences of 11.9% and 15.6% in the red channel at 2 Gy between 50–225 kVp and 80–225 kVp photon spectra, respectively. We observed that the triple-channel method resulted in non-uniformity corrections of ±1% and consistency values of 0–3 cGy for the batches and dose levels studied. Results of this study indicate that the triple-channel radiochromic film read-out method performs at least as well as the single-channel method with inclusion of a pre-IR film scan, reduces film non-uniformity and saves time with elimination of a pre-IR film scan. (paper)

  5. Triple M” Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation

    Science.gov (United States)

    Mortazavi, Gh.; Mortazavi, S.A.R.; Mehdizadeh, A.R.

    2018-01-01

    A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobile phones and magnetic resonance imaging (MRI). Studies performed on the increased microleakage of dental amalgam restorations after exposure to RF-EMFs have further supported these findings. Although the accelerated microleakage induced by RF-EMFs is clinically significant, the entire mechanisms of this phenomenon are not clearly understood. In this paper, we introduce “Triple M” effect, a new evidence-based theory which can explain the accelerated microleakage of dental amalgam fillings after exposure to different sources of electromagnetic radiation. Based on this theory, there are saliva-filled tiny spaces between amalgam and the tooth. Exposure of the oral cavity to RF-EMFs increases the energy of these small amounts of saliva. Due to the small mass of saliva in these tiny spaces, a small amount of energy will be required for heating. Moreover, reflection of the radiofrequency radiation on the inner walls of the tiny spaces causes interference which in turn produces some “hot spots” in these spaces. Finally, formation of gas bubbles in response to increased temperature and very rapid expansion of these bubbles will accelerate the microleakage of amalgam. Experiments that confirm the validity of this theory are discussed. PMID:29732349

  6. "Triple M" Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation.

    Science.gov (United States)

    Mortazavi, Gh; Mortazavi, S A R; Mehdizadeh, A R

    2018-03-01

    A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobile phones and magnetic resonance imaging (MRI). Studies performed on the increased microleakage of dental amalgam restorations after exposure to RF-EMFs have further supported these findings. Although the accelerated microleakage induced by RF-EMFs is clinically significant, the entire mechanisms of this phenomenon are not clearly understood. In this paper, we introduce "Triple M" effect, a new evidence-based theory which can explain the accelerated microleakage of dental amalgam fillings after exposure to different sources of electromagnetic radiation. Based on this theory, there are saliva-filled tiny spaces between amalgam and the tooth. Exposure of the oral cavity to RF-EMFs increases the energy of these small amounts of saliva. Due to the small mass of saliva in these tiny spaces, a small amount of energy will be required for heating. Moreover, reflection of the radiofrequency radiation on the inner walls of the tiny spaces causes interference which in turn produces some "hot spots" in these spaces. Finally, formation of gas bubbles in response to increased temperature and very rapid expansion of these bubbles will accelerate the microleakage of amalgam. Experiments that confirm the validity of this theory are discussed.

  7. Silicon tracker end cap of the CMS experiment at LHC and study of the discovery potential for resonances decaying in top quark pairs; Integration d'un bouchon du trajectographe au silicium de l'experience CMS au LHC et etude du potentiel de decouverte de resonances se desintegrant en paires de quarks top

    Energy Technology Data Exchange (ETDEWEB)

    Chabert, E

    2008-10-15

    The first part of this thesis is dedicated to the integration of one silicon tracker end cap of the CMS experiment. The procedures implemented and the tests that led to the qualification of the detection system are presented in this document. The first chapter is an introduction to the LHC and to the CMS experiment. The second chapter is dedicated to the CMS tracker, that is a detector made up of silicon micro-stripe whose purpose is to reconstruct the tracks of charged-particles, to measure their momentum, to reconstruct vertex and to contribute to the tagging of heavy flavour quarks. The third chapter presents the integration of one of the tracker end caps. The second part of this thesis is dedicated to the search for new physics in the top quark sector. One of the most promising channel is to look for a resonance in the invariant mass distribution of top quark pairs. The fourth chapter is a theoretical introduction to this work, the standard model is introduced and the top quarks physics as well as tt-bar resonances are highlighted. The fifth chapter describes the tools used to analyse data, all the data come from simulations. The search for tt-bar resonances is presented in the last chapter. This search involves a method to select right events, a strategy to reduce background noise and a method for the reconstruction of the events. A kinematical adjustment is made to identify the right combinations of jets and to improve the experimental resolution on the invariant mass. The full simulation analysis in the 'lepton + jets' channel shows that at the TeV scale, processes from a few hundred fb to one pb could be observed in the early years of data taking.

  8. Writing with resonance

    DEFF Research Database (Denmark)

    Meier, Ninna; Wegener, Charlotte

    2017-01-01

    In this article, we explore what organization and management scholars can do to write with resonance and to facilitate an emotional, bodily, or in other ways sensory connection between the text and the reader. We propose that resonance can be relevant for organization and management scholars in two......, and thus bring forward the field of research in question. We propose that writing with resonance may be a way to further the impact of academic work by extending the modalities with which our readers can relate to and experience our work....

  9. On Pythagoras Theorem for Products of Spectral Triples

    OpenAIRE

    D'Andrea, Francesco; Martinetti, Pierre

    2013-01-01

    We discuss a version of Pythagoras theorem in noncommutative geometry. Usual Pythagoras theorem can be formulated in terms of Connes' distance, between pure states, in the product of commutative spectral triples. We investigate the generalization to both non pure states and arbitrary spectral triples. We show that Pythagoras theorem is replaced by some Pythagoras inequalities, that we prove for the product of arbitrary (i.e. non-necessarily commutative) spectral triples, assuming only some un...

  10. Targeting Histone Abnormality in Triple Negative Breast Cancer

    Science.gov (United States)

    2015-08-01

    κB pathway in triple negative breast cancer . 8th International Nitric Oxide Conference & 6th International Nitrite/ Nitrate Conference, Cleveland, OH...1 AWARD NUMBER: W81XWH-14-1-0237 TITLE: Targeting Histone Abnormality in Triple-Negative Breast Cancer PRINCIPAL INVESTIGATOR: Yi...TITLE AND SUBTITLE 5a. CONTRACT NUMBER Targeting Histone Abnormality in Triple-Negative Breast Cancer 5b. GRANT NUMBER W81XWH-14-1-0237 5c

  11. Natural triple beta-stranded fibrous folds.

    Science.gov (United States)

    Mitraki, Anna; Papanikolopoulou, Katerina; Van Raaij, Mark J

    2006-01-01

    A distinctive family of beta-structured folds has recently been described for fibrous proteins from viruses. Virus fibers are usually involved in specific host-cell recognition. They are asymmetric homotrimeric proteins consisting of an N-terminal virus-binding tail, a central shaft or stalk domain, and a C-terminal globular receptor-binding domain. Often they are entirely or nearly entirely composed of beta-structure. Apart from their biological relevance and possible gene therapy applications, their shape, stability, and rigidity suggest they may be useful as blueprints for biomechanical design. Folding and unfolding studies suggest their globular C-terminal domain may fold first, followed by a "zipping-up" of the shaft domains. The C-terminal domains appear to be important for registration because peptides corresponding to shaft domains alone aggregate into nonnative fibers and/or amyloid structures. C-terminal domains can be exchanged between different fibers and the resulting chimeric proteins are useful as a way to solve structures of unknown parts of the shaft domains. The following natural triple beta-stranded fibrous folds have been discovered by X-ray crystallography: the triple beta-spiral, triple beta-helix, and T4 short tail fiber fold. All have a central longitudinal hydrophobic core and extensive intermonomer polar and nonpolar interactions. Now that a reasonable body of structural and folding knowledge has been assembled about these fibrous proteins, the next challenge and opportunity is to start using this information in medical and industrial applications such as gene therapy and nanotechnology.

  12. The Triple Axis and SPINS Spectrometers.

    Science.gov (United States)

    Trevino, S F

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments.

  13. Binaries and triples among asteroid pairs

    Science.gov (United States)

    Pravec, Petr; Scheirich, Peter; Kušnirák, Peter; Hornoch, Kamil; Galád, Adrián

    2015-08-01

    Despite major achievements obtained during the past two decades, our knowledge of the population and properties of small binary and multiple asteroid systems is still far from advanced. There is a numerous indirect evidence for that most small asteroid systems were formed by rotational fission of cohesionless parent asteroids that were spun up to the critical frequency presumably by YORP, but details of the process are lacking. Furthermore, as we proceed with observations of more and more binary and paired asteroids, we reveal new facts that substantially refine and sometimes change our understanding of the asteroid systems. One significant new finding we have recently obtained is that primaries of many asteroid pairs are actually binary or triple systems. The first such case found is (3749) Balam (Vokrouhlický, ApJL 706, L37, 2009). We have found 9 more binary systems among asteroid pairs within our ongoing NEOSource photometric project since October 2012. They are (6369) 1983 UC, (8306) Shoko, (9783) Tensho-kan, (10123) Fideoja, (21436) Chaoyichi, (43008) 1999 UD31, (44620) 1999 RS43, (46829) 1998 OS14 and (80218) 1999 VO123. We will review their characteristics. These paired binaries as we call them are mostly similar to binaries in the general ("background") population (of unpaired asteroids), but there are a few trends. The paired binaries tend to have larger secondaries with D_2/D_1 = 0.3 to 0.5 and they also tend to be wider systems with 8 of the 10 having orbital periods between 30 and 81 hours, than average among binaries in the general population. There may be also a larger fraction of triples; (3749) Balam is a confirmed triple, having a larger close and a smaller distant satellite, and (8306) Shoko and (10123) Fideoja are suspect triples as they show additional rotational lightcurve components with periods of 61 and 38.8 h that differ from the orbital period of 36.2 and 56.5 h, respectively. The unbound secondaries tend to be of the same size or

  14. Experimental observation of triple correlations in fluids

    Directory of Open Access Journals (Sweden)

    M.Ya. Sushko

    2013-03-01

    Full Text Available We present arguments for the hypothesis that under some conditions, triple correlations of density fluctuations in fluids can be detected experimentally by the method of molecular spectroscopy. These correlations manifest themselves in the form of so-called 1.5-(or sesquialteral scattering. The latter is of most significance in the pre-asymptotic vicinity of the critical point and can be registered along certain thermodynamic paths. Its presence in the overall scattering pattern is demonstrated by our processing available experimental data for the depolarization factor. Some consequences of these results are discussed.

  15. Nonlinear optical response of the collagen triple helix and second harmonic microscopy of collagen liquid crystals

    Science.gov (United States)

    Deniset-Besseau, A.; De Sa Peixoto, P.; Duboisset, J.; Loison, C.; Hache, F.; Benichou, E.; Brevet, P.-F.; Mosser, G.; Schanne-Klein, M.-C.

    2010-02-01

    Collagen is characterized by triple helical domains and plays a central role in the formation of fibrillar and microfibrillar networks, basement membranes, as well as other structures of the connective tissue. Remarkably, fibrillar collagen exhibits efficient Second Harmonic Generation (SHG) and SHG microscopy proved to be a sensitive tool to score fibrotic pathologies. However, the nonlinear optical response of fibrillar collagen is not fully characterized yet and quantitative data are required to further process SHG images. We therefore performed Hyper-Rayleigh Scattering (HRS) experiments and measured a second order hyperpolarisability of 1.25 10-27 esu for rat-tail type I collagen. This value is surprisingly large considering that collagen presents no strong harmonophore in its amino-acid sequence. In order to get insight into the physical origin of this nonlinear process, we performed HRS measurements after denaturation of the collagen triple helix and for a collagen-like short model peptide [(Pro-Pro-Gly)10]3. It showed that the collagen large nonlinear response originates in the tight alignment of a large number of weakly efficient harmonophores, presumably the peptide bonds, resulting in a coherent amplification of the nonlinear signal along the triple helix. To illustrate this mechanism, we successfully recorded SHG images in collagen liquid solutions by achieving liquid crystalline ordering of the collagen triple helices.

  16. Decreased triple network connectivity in patients with post-traumatic stress disorder

    Science.gov (United States)

    Liu, Yang; Li, Liang; Li, Baojuan; Zhang, Xi; Lu, Hongbing

    2017-03-01

    The triple network model provides a common framework for understanding affective and neurocognitive dysfunctions across multiple disorders, including central executive network (CEN), default mode network (DMN), and salience network (SN). Considering the effect of traumatic experience on post-traumatic stress disorder (PTSD), this study aims to explore the alteration of triple network connectivity in a specific PTSD induced by a single prolonged trauma exposure. With arterial spin labeling sequence, three networks were identified using independent component analysis in 10 PTSD patients and 10 healthy survivors, who experienced the same coal mining flood disaster. In PTSD patients, decreased connectivity was identified in left middle frontal gyrus of CEN, left precuneus and bilateral superior frontal gyrus of DMN, and right anterior insula of SN. The decreased connectivity in left middle frontal gyrus was identified to associate with clinical severity. These results indicated the decreased triple network connectivity, which not only supported the proposal of the triple network model, but also prompted possible neurobiology mechanism of cognitive dysfunction for this kind of PTSD.

  17. Synchronous triple urogenital cancer (renal cancer, bladder cancer, prostatic cancer). A case report

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Tsuyoshi; Honda, Masahito; Momohara, Chikahiro; Komori, Kazuhiko; Fujioka, Hideki [Osaka Police Hospital (Japan)

    2002-04-01

    A case of synchronous triple urogenital cancer, which was comprised of renal cell carcinoma of the left kidney, transitional cell carcinoma of the urinary bladder, and adenocarcinoma of the prostate, is reported. A 72-year-old Japanese male patient was referred to our outpatient clinic with the complaint of asymptomatic hematuria. At that time, his serum of level of PSA was elevated to 20 ng/ml. Cystourethroscopy showed a papillary bladder tumor and coagula through the left urinary orifice. Ultrasonography, computed tomography and magnetic resonance imaging showed a mass lesion measuring about 6 cm by 5 cm in the left kidney. Angiography showed a hypervascular lesion measuring about 6 cm by 5 cm at the same site. Double cancer, consisting of renal cell carcinoma and transitional cell carcinoma of the urinary bladder, was suspected and we performed left total nephroureterectomy, hilar lymphadenectomy, and transurethral rection of the bladder tumor, one month later. At the same time, we performed a biopsy of the prostate. Histological diagnosis was renal cell carcinoma, clear cell carcinoma and transitional cell carcinoma of urinary bladder. Histological diagnosis of the prostate biopsy was moderately differentiated adenocarcinoma. Since this case fulfilled the criteria of Warren and Gates, it was classified as synchronous triple urogenital cancer. A review of the literature revealed 17 authentic cases of triple urogenital cancer, of which 14 and 10 cases were reported as a combination of renal cancer, bladder cancer and prostatic cancer, in the world and in Japan, respectively. Furthermore, he had been exposed to the atomic bomb explosion in Hiroshima in 1945. This carcinogenic precursor may be related to the development of the triple cancer. (author)

  18. Synchronous triple urogenital cancer (renal cancer, bladder cancer, prostatic cancer). A case report

    International Nuclear Information System (INIS)

    Takada, Tsuyoshi; Honda, Masahito; Momohara, Chikahiro; Komori, Kazuhiko; Fujioka, Hideki

    2002-01-01

    A case of synchronous triple urogenital cancer, which was comprised of renal cell carcinoma of the left kidney, transitional cell carcinoma of the urinary bladder, and adenocarcinoma of the prostate, is reported. A 72-year-old Japanese male patient was referred to our outpatient clinic with the complaint of asymptomatic hematuria. At that time, his serum of level of PSA was elevated to 20 ng/ml. Cystourethroscopy showed a papillary bladder tumor and coagula through the left urinary orifice. Ultrasonography, computed tomography and magnetic resonance imaging showed a mass lesion measuring about 6 cm by 5 cm in the left kidney. Angiography showed a hypervascular lesion measuring about 6 cm by 5 cm at the same site. Double cancer, consisting of renal cell carcinoma and transitional cell carcinoma of the urinary bladder, was suspected and we performed left total nephroureterectomy, hilar lymphadenectomy, and transurethral rection of the bladder tumor, one month later. At the same time, we performed a biopsy of the prostate. Histological diagnosis was renal cell carcinoma, clear cell carcinoma and transitional cell carcinoma of urinary bladder. Histological diagnosis of the prostate biopsy was moderately differentiated adenocarcinoma. Since this case fulfilled the criteria of Warren and Gates, it was classified as synchronous triple urogenital cancer. A review of the literature revealed 17 authentic cases of triple urogenital cancer, of which 14 and 10 cases were reported as a combination of renal cancer, bladder cancer and prostatic cancer, in the world and in Japan, respectively. Furthermore, he had been exposed to the atomic bomb explosion in Hiroshima in 1945. This carcinogenic precursor may be related to the development of the triple cancer. (author)

  19. Snake resonances

    International Nuclear Information System (INIS)

    Tepikian, S.

    1988-01-01

    Siberian Snakes provide a practical means of obtaining polarized proton beams in large accelerators. The effect of snakes can be understood by studying the dynamics of spin precession in an accelerator with snakes and a single spin resonance. This leads to a new class of energy independent spin depolarizing resonances, called snake resonances. In designing a large accelerator with snakes to preserve the spin polarization, there is an added constraint on the choice of the vertical betatron tune due to the snake resonances. 11 refs., 4 figs

  20. Dispersion cancellation in a triple Laue interferometer

    International Nuclear Information System (INIS)

    Lemmel, Hartmut

    2014-01-01

    The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasn't been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrödinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer. (paper)

  1. Robust Modeling of Stellar Triples in PHOEBE

    Science.gov (United States)

    Conroy, Kyle E.; Prsa, Andrej; Horvat, Martin; Stassun, Keivan G.

    2017-01-01

    The number of known mutually-eclipsing stellar triple and multiple systems has increased greatly during the Kepler era. These systems provide significant opportunities to both determine fundamental stellar parameters of benchmark systems to unprecedented precision as well as to study the dynamical interaction and formation mechanisms of stellar and planetary systems. Modeling these systems to their full potential, however, has not been feasible until recently. Most existing available codes are restricted to the two-body binary case and those that do provide N-body support for more components make sacrifices in precision by assuming no stellar surface distortion. We have completely redesigned and rewritten the PHOEBE binary modeling code to incorporate support for triple and higher-order systems while also robustly modeling data with Kepler precision. Here we present our approach, demonstrate several test cases based on real data, and discuss the current status of PHOEBE's support for modeling these types of systems. PHOEBE is funded in part by NSF grant #1517474.

  2. VERITAS: Versatile Triple-Axis Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  3. VERITAS: Versatile Triple-Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  4. Monte Carlo analysis of the long-lived fission product neutron capture rates at the Transmutation by Adiabatic Resonance Crossing (TARC) experiment

    International Nuclear Information System (INIS)

    Abánades, A.; Álvarez-Velarde, F.; González-Romero, E.M.; Ismailov, K.; Lafuente, A.; Nishihara, K.; Saito, M.; Stanculescu, A.; Sugawara, T.

    2013-01-01

    Highlights: ► TARC experiment benchmark capture rates results. ► Utilization of updated databases, included ADSLib. ► Self-shielding effect in reactor design for transmutation. ► Effect of Lead nuclear data. - Abstract: The design of Accelerator Driven Systems (ADS) requires the development of simulation tools that are able to describe in a realistic way their nuclear performance and transmutation rate capability. In this publication, we present an evaluation of state of the art Monte Carlo design tools to assess their performance concerning transmutation of long-lived fission products. This work, performed under the umbrella of the International Atomic Energy Agency, analyses two important aspects for transmutation systems: moderation on Lead and neutron captures of 99 Tc, 127 I and 129 I. The analysis of the results shows how shielding effects due to the resonances at epithermal energies of these nuclides affects strongly their transmutation rate. The results suggest that some research effort should be undertaken to improve the quality of Iodine nuclear data at epithermal and fast neutron energy to obtain a reliable transmutation estimation.

  5. Monte Carlo analysis of the long-lived fission product neutron capture rates at the Transmutation by Adiabatic Resonance Crossing (TARC) experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abanades, A., E-mail: abanades@etsii.upm.es [Grupo de Modelizacion de Sistemas Termoenergeticos, ETSII, Universidad Politecnica de Madrid, c/Ramiro de Maeztu, 7, 28040 Madrid (Spain); Alvarez-Velarde, F.; Gonzalez-Romero, E.M. [Centro de Investigaciones Medioambientales y Tecnologicas (CIEMAT), Avda. Complutense, 40, Ed. 17, 28040 Madrid (Spain); Ismailov, K. [Tokyo Institute of Technology, 2-12-1, O-okayama, Meguro-ku, Tokyo 152-8550 (Japan); Lafuente, A. [Grupo de Modelizacion de Sistemas Termoenergeticos, ETSII, Universidad Politecnica de Madrid, c/Ramiro de Maeztu, 7, 28040 Madrid (Spain); Nishihara, K. [Transmutation Section, J-PARC Center, JAEA, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Saito, M. [Tokyo Institute of Technology, 2-12-1, O-okayama, Meguro-ku, Tokyo 152-8550 (Japan); Stanculescu, A. [International Atomic Energy Agency (IAEA), Vienna (Austria); Sugawara, T. [Transmutation Section, J-PARC Center, JAEA, Tokai-mura, Ibaraki-ken 319-1195 (Japan)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer TARC experiment benchmark capture rates results. Black-Right-Pointing-Pointer Utilization of updated databases, included ADSLib. Black-Right-Pointing-Pointer Self-shielding effect in reactor design for transmutation. Black-Right-Pointing-Pointer Effect of Lead nuclear data. - Abstract: The design of Accelerator Driven Systems (ADS) requires the development of simulation tools that are able to describe in a realistic way their nuclear performance and transmutation rate capability. In this publication, we present an evaluation of state of the art Monte Carlo design tools to assess their performance concerning transmutation of long-lived fission products. This work, performed under the umbrella of the International Atomic Energy Agency, analyses two important aspects for transmutation systems: moderation on Lead and neutron captures of {sup 99}Tc, {sup 127}I and {sup 129}I. The analysis of the results shows how shielding effects due to the resonances at epithermal energies of these nuclides affects strongly their transmutation rate. The results suggest that some research effort should be undertaken to improve the quality of Iodine nuclear data at epithermal and fast neutron energy to obtain a reliable transmutation estimation.

  6. Leakage and sweet spots in triple-quantum-dot spin qubits: A molecular-orbital study

    Science.gov (United States)

    Zhang, Chengxian; Yang, Xu-Chen; Wang, Xin

    2018-04-01

    A triple-quantum-dot system can be operated as either an exchange-only qubit or a resonant-exchange qubit. While it is generally believed that the decisive advantage of the resonant-exchange qubit is the suppression of charge noise because it is operated at a sweet spot, we show that the leakage is also an important factor. Through molecular-orbital-theoretic calculations, we show that when the system is operated in the exchange-only scheme, the leakage to states with double electron occupancy in quantum dots is severe when rotations around the axis 120∘ from z ̂ is performed. While this leakage can be reduced by either shrinking the dots or separating them further, the exchange interactions are also suppressed at the same time, making the gate operations unfavorably slow. When the system is operated as a resonant-exchange qubit, the leakage is three to five orders of magnitude smaller. We have also calculated the optimal detuning point which minimizes the leakage for the resonant-exchange qubit, and have found that although it does not coincide with the double sweet spot for the charge noise, they are rather close. Our results suggest that the resonant-exchange qubit has another advantage, that leakage can be greatly suppressed compared to the exchange-only qubit, and operating at the double sweet spot point should be optimal both for reducing charge noise and suppressing leakage.

  7. Quasiresonant formation of dtμ mesic molecules in triple collisions

    International Nuclear Information System (INIS)

    Men'shikov, L.I.; Ponomarev, L.I.

    1985-01-01

    A quasiresonant mechanism of mesic molecules formation, in triple collisions of the type tμ+D 2 +D 2 → [(dtμ)d2e] * +D ν is considered. It is shown that at small resonance defects and big D 2 +T 2 mixture densities φ the rate of this process λ qr ∼ φ 2 and it is comparable with the rate λ r ∼ φ of the mesic molecules resonant formation in the reactions of the type tμ+D 2 → [(dtμ)d2e] ν *. The observable manifestations of the process considered and its role in the muon catalyzed fusion in deuterium-tritium mixture are discussed

  8. BROWN DWARF BINARIES FROM DISINTEGRATING TRIPLE SYSTEMS

    International Nuclear Information System (INIS)

    Reipurth, Bo; Mikkola, Seppo

    2015-01-01

    Binaries in which both components are brown dwarfs (BDs) are being discovered at an increasing rate, and their properties may hold clues to their origin. We have carried out 200,000 N-body simulations of three identical stellar embryos with masses drawn from a Chabrier IMF and embedded in a molecular core. The bodies are initially non-hierarchical and undergo chaotic motions within the cloud core, while accreting using Bondi–Hoyle accretion. The coupling of dynamics and accretion often leads to one or two dominant bodies controlling the center of the cloud core, while banishing the other(s) to the lower-density outskirts, leading to stunted growth. Eventually each system transforms either to a bound hierarchical configuration or breaks apart into separate single and binary components. The orbital motion is followed for 100 Myr. In order to illustrate 200,000 end-states of such dynamical evolution with accretion, we introduce the “triple diagnostic diagram,” which plots two dimensionless numbers against each other, representing the binary mass ratio and the mass ratio of the third body to the total system mass. Numerous freefloating BD binaries are formed in these simulations, and statistical properties are derived. The separation distribution function is in good correspondence with observations, showing a steep rise at close separations, peaking around 13 AU and declining more gently, reaching zero at separations greater than 200 AU. Unresolved BD triple systems may appear as wider BD binaries. Mass ratios are strongly peaked toward unity, as observed, but this is partially due to the initial assumptions. Eccentricities gradually increase toward higher values, due to the lack of viscous interactions in the simulations, which would both shrink the orbits and decrease their eccentricities. Most newborn triple systems are unstable and while there are 9209 ejected BD binaries at 1 Myr, corresponding to about 4% of the 200,000 simulations, this number has grown to

  9. BROWN DWARF BINARIES FROM DISINTEGRATING TRIPLE SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Reipurth, Bo [Institute for Astronomy and NASA Astrobiology Institute University of Hawaii, 640 N. Aohoku Place, Hilo, HI 96720 (United States); Mikkola, Seppo, E-mail: reipurth@ifa.hawaii.edu, E-mail: Seppo.Mikkola@utu.fi [Tuorla Observatory, University of Turku, Väisäläntie 20, Piikkiö (Finland)

    2015-04-15

    Binaries in which both components are brown dwarfs (BDs) are being discovered at an increasing rate, and their properties may hold clues to their origin. We have carried out 200,000 N-body simulations of three identical stellar embryos with masses drawn from a Chabrier IMF and embedded in a molecular core. The bodies are initially non-hierarchical and undergo chaotic motions within the cloud core, while accreting using Bondi–Hoyle accretion. The coupling of dynamics and accretion often leads to one or two dominant bodies controlling the center of the cloud core, while banishing the other(s) to the lower-density outskirts, leading to stunted growth. Eventually each system transforms either to a bound hierarchical configuration or breaks apart into separate single and binary components. The orbital motion is followed for 100 Myr. In order to illustrate 200,000 end-states of such dynamical evolution with accretion, we introduce the “triple diagnostic diagram,” which plots two dimensionless numbers against each other, representing the binary mass ratio and the mass ratio of the third body to the total system mass. Numerous freefloating BD binaries are formed in these simulations, and statistical properties are derived. The separation distribution function is in good correspondence with observations, showing a steep rise at close separations, peaking around 13 AU and declining more gently, reaching zero at separations greater than 200 AU. Unresolved BD triple systems may appear as wider BD binaries. Mass ratios are strongly peaked toward unity, as observed, but this is partially due to the initial assumptions. Eccentricities gradually increase toward higher values, due to the lack of viscous interactions in the simulations, which would both shrink the orbits and decrease their eccentricities. Most newborn triple systems are unstable and while there are 9209 ejected BD binaries at 1 Myr, corresponding to about 4% of the 200,000 simulations, this number has grown to

  10. Recovery and normalization of triple coincidences in PET

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.; Herraiz, Joaquin L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Moore, Stephen C.; Sitek, Arkadiusz; Park, Mi-Ae [Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States); Udías, Jose M. [Grupo de Física Nuclear, Departamento de Física Atómica Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Vaquero, Juan J. [Departamento de Ingeniería Biomédica e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Leganés 28911 (Spain)

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the

  11. Recovery and normalization of triple coincidences in PET.

    Science.gov (United States)

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak

  12. Practical consensus recommendations on management of triple-negative metastatic breast cancer

    Directory of Open Access Journals (Sweden)

    R Rangarao

    2018-01-01

    Full Text Available Patients with breast cancer along with metastatic estrogen and progesterone receptor (ER/PR- and human epidermal growth factor receptor 2 (HER2-negative tumors are referred to as having metastatic triple-negative breast cancer (mTNBC disease. Resistance to current standard therapies such as anthracyclines or taxanes limits the available options for previously treated patients with metastatic TNBC to a small number of non-cross-resistant regimens, and there is currently no preferred standard chemotherapy. Clinical experience suggests that many women with triple-negative metastatic breast cancer (MBC relapse quickly. Expert oncologist discussed about new chemotherapeutic strategies and agents used in treatment of mTNBC and the expert group used data from published literature, practical experience and opinion of a large group of academic oncologists to arrive at this practical consensus recommendations for the benefit of community oncologists.

  13. Ferromagnetic resonance in a single crystal of iron borate and magnetic field tuning of hybrid oscillations in a composite structure with a dielectric: Experiment and theory

    International Nuclear Information System (INIS)

    Popov, M. A.; Zavislyak, I. V.; Chumak, H. L.; Strugatsky, M. B.; Yagupov, S. V.; Srinivasan, G.

    2015-01-01

    The high-frequency properties of a composite resonator comprised single crystal iron borate (FeBO 3 ), a canted antiferromagnet with a weak ferromagnetic moment, and a polycrystalline dielectric were investigated at 9–10 GHz. Ferromagnetic resonance in this frequency range was observed in FeBO 3 for bias magnetic fields of ∼250 Oe. In the composite resonator, the magnetic mode in iron borate and dielectric mode are found to hybridize strongly. It is shown that the hybrid mode can be tuned with a static magnetic field. Our studies indicate that coupling between the magnetic mode and the dielectric resonance can be altered from maximum hybridization to a minimum by adjusting the position of resonator inside the waveguide. Magnetic field tuning of the resonance frequency by a maximum of 145 MHz and a change in the transmitted microwave power by as much as 16 dB have been observed for a bias field of 250 Oe. A model is discussed for the magnetic field tuning of the composite resonator and theoretical estimates are in reasonable agreement with the data. The composite resonator with a weak ferromagnet and a dielectric is of interest for application in frequency agile devices with electronically tunable electrodynamic characteristics for the mm and sub-mm wave bands

  14. Study of {upsilon} family resonances in ultrarelativistic heavy ions collisions within the frame of the Alice experiment at CERN-LHC; Etude des resonances de la famille du {upsilon} dans les collisions d'ions lourds ultra-relativistes a 2.75 TeV/ nucleon et par faisceau sur l'experience Alice du LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dumonteil, E

    2004-09-01

    Quantum Chromodynamics foresees, at high temperature and/or high energy density, a phase transition between hadronic matter and a phase where quarks and gluons are no more confined in the nucleons: the Quark Gluon Plasma (QGP). During the past fifteen years, a large experimental program has taken place at CERN and at BNL, to identify the QGP. ALICE is the LHC experiment dedicated to the study of the plasma via ultrarelativistic heavy ion collisions at 2.75 TeV/nucleon per beam. The measure of Upsilon's resonances suppression, a powerful signature of a deconfined medium, with the ALICE dimuon spectrometer, is the main topic of this thesis. The first part of the work aims at studying the multi-wires pad chambers of the dimuon arm, used to track the muons from resonances decays. The second part presents an in-beam alignment algorithm able to calculate the positions of the different chambers with a very good accuracy. Finally, the last part proposes a study to lead with the ALICE muon spectrometer, involving the measure of Upsilon and Upsilon's production ratio as a function of the transverse momentum. It has been showed that this study should allow to evidence the QGP and to extract some of its properties. (author)

  15. Symmetric Stream Cipher using Triple Transposition Key Method and Base64 Algorithm for Security Improvement

    Science.gov (United States)

    Nurdiyanto, Heri; Rahim, Robbi; Wulan, Nur

    2017-12-01

    Symmetric type cryptography algorithm is known many weaknesses in encryption process compared with asymmetric type algorithm, symmetric stream cipher are algorithm that works on XOR process between plaintext and key, to improve the security of symmetric stream cipher algorithm done improvisation by using Triple Transposition Key which developed from Transposition Cipher and also use Base64 algorithm for encryption ending process, and from experiment the ciphertext that produced good enough and very random.

  16. The QCD Phase Diagram: Large Nc, Quarkyonic Matter and the Triple Point

    International Nuclear Information System (INIS)

    McLerran, L.

    2010-01-01

    I discuss the phase diagram of QCD in the large N c limit. Qarkyonic Matter is described. The properties of QCD matter as measured in the abundance of produced particles are shown to be consistent with this phase diagram. A possible triple point of Hadronic Matter, Deconfined Matter and Quarkyonic Matter is shown to explain various behaviors of ratios of particle abundances seen in CERN fixed target experiments. (author)

  17. Measurement of WW production with the ATLAS detector and constraints on associated triple gauge couplings

    CERN Document Server

    Liu, JB; The ATLAS collaboration

    2013-01-01

    The measurement of the WW diboson production cross section in proton proton interactions with the ATLAS experiment is presented. The measurement is performed using W boson fully leptonical decays including ee, emu and mumu final states associated with large missing energy. Measured total and differential cross sections of WW production are compared to NLO predictions of the standard model. Leading lepton pT distribution is used to place constraints on anomalous triple gauge boson couplings.

  18. Improving Ambiguity Resolution for Medium Baselines Using Combined GPS and BDS Dual/Triple-Frequency Observations.

    Science.gov (United States)

    Gao, Wang; Gao, Chengfa; Pan, Shuguo; Wang, Denghui; Deng, Jiadong

    2015-10-30

    The regional constellation of the BeiDou navigation satellite system (BDS) has been providing continuous positioning, navigation and timing services since 27 December 2012, covering China and the surrounding area. Real-time kinematic (RTK) positioning with combined BDS and GPS observations is feasible. Besides, all satellites of BDS can transmit triple-frequency signals. Using the advantages of multi-pseudorange and carrier observations from multi-systems and multi-frequencies is expected to be of much benefit for ambiguity resolution (AR). We propose an integrated AR strategy for medium baselines by using the combined GPS and BDS dual/triple-frequency observations. In the method, firstly the extra-wide-lane (EWL) ambiguities of triple-frequency system, i.e., BDS, are determined first. Then the dual-frequency WL ambiguities of BDS and GPS were resolved with the geometry-based model by using the BDS ambiguity-fixed EWL observations. After that, basic (i.e., L1/L2 or B1/B2) ambiguities of BDS and GPS are estimated together with the so-called ionosphere-constrained model, where the ambiguity-fixed WL observations are added to enhance the model strength. During both of the WL and basic AR, a partial ambiguity fixing (PAF) strategy is adopted to weaken the negative influence of new-rising or low-elevation satellites. Experiments were conducted and presented, in which the GPS/BDS dual/triple-frequency data were collected in Nanjing and Zhengzhou of China, with the baseline distance varying from about 28.6 to 51.9 km. The results indicate that, compared to the single triple-frequency BDS system, the combined system can significantly enhance the AR model strength, and thus improve AR performance for medium baselines with a 75.7% reduction of initialization time on average. Besides, more accurate and stable positioning results can also be derived by using the combined GPS/BDS system.

  19. Triple Play Service and IPTV Services Offered within it

    Directory of Open Access Journals (Sweden)

    Dagmar Pajdusakova

    2008-01-01

    Full Text Available This paper deals with Triple Play multimedia service and figures its architecture. Triple Play offers voice, video and data services together in one customer connection. There is offered IPTV (Internet Protocol Television service within this service, where we can include also Video on Demand service and other different additional services. In the paper is described classification of Video on Demand services.

  20. Absolute migration and the evolution of the Rodriguez triple junction ...

    African Journals Online (AJOL)

    The Rodriguez Triple Junction (RTJ) is a junction connecting three mid-ocean ridges in the Indian Ocean: the Southwest Indian Ridge (SWIR), the Central Indian Ridge (CIR) and the Southeast Indian Ridge (SEIR). The evolution of the RTJ has been studied extensively for the past 10 Ma and the triple junction is believed to ...

  1. Government and Governance of Regional Triple Helix Interactions

    Science.gov (United States)

    Danson, Mike; Todeva, Emanuela

    2016-01-01

    This conceptual paper contributes to the discussion of the role of regional government and regional Triple Helix constellations driving economic development and growth within regional boundaries. The impact of regionalism and subsidiarity on regional Triple Helix constellations, and the questions of governmentality, governance and institutional…

  2. Unexpected Hydration of a Triple Bond During DNA Synthesis

    DEFF Research Database (Denmark)

    Fatthalla, Maha I.; Pedersen, Erik B.

    2016-01-01

    acidic conditions, polarizes the triple bond in the intercalator and this makes hydration of the triple bond possible during the DNA synthesis and an oligonucleotide with 1-(indol-3-yl)-2-(pyren-1-yl)ethanone as the intercalator is formed. Insertion of the unhydrated and hydrated linker systems gave...

  3. Triple junction polymer solar cells for photoelectrochemical water splitting

    NARCIS (Netherlands)

    Esiner, S.; Eersel, van H.; Wienk, M.M.; Janssen, R.A.J.

    2013-01-01

    A triple junction polymer solar cell in a novel 1 + 2 type configuration provides photoelectrochemical water splitting in its maximum power point at V ˜ 1.70 V with an estimated solar to hydrogen energy conversion efficiency of 3.1%. The triple junction cell consists of a wide bandgap front cell and

  4. Regional Dimensions of the Triple Helix Model: Setting the Context

    Science.gov (United States)

    Todeva, Emanuela; Danson, Mike

    2016-01-01

    This paper introduces the rationale for the special issue and its contributions, which bridge the literature on regional development and the Triple Helix model. The concept of the Triple Helix at the sub-national, and specifically regional, level is established and examined, with special regard to regional economic development founded on…

  5. "Special Issue": Regional Dimensions of the Triple Helix Model

    Science.gov (United States)

    Todeva, Emanuela; Danson, Mike

    2016-01-01

    This paper introduces the rationale for the special issue and its contributions, which bridge the literature on regional development and the Triple Helix model. The concept of the Triple Helix at the sub-national, and specifically regional, level is established and examined, with special regard to regional economic development founded on…

  6. Nonlinear resonances

    CERN Document Server

    Rajasekar, Shanmuganathan

    2016-01-01

    This introductory text presents the basic aspects and most important features of various types of resonances and anti-resonances in dynamical systems. In particular, for each resonance, it covers the theoretical concepts, illustrates them with case studies, and reviews the available information on mechanisms, characterization, numerical simulations, experimental realizations, possible quantum analogues, applications and significant advances made over the years. Resonances are one of the most fundamental phenomena exhibited by nonlinear systems and refer to specific realizations of maximum response of a system due to the ability of that system to store and transfer energy received from an external forcing source. Resonances are of particular importance in physical, engineering and biological systems - they can prove to be advantageous in many applications, while leading to instability and even disasters in others. The book is self-contained, providing the details of mathematical derivations and techniques invo...

  7. Chemical shift-dependent apparent scalar couplings: An alternative concept of chemical shift monitoring in multi-dimensional NMR experiments

    International Nuclear Information System (INIS)

    Kwiatkowski, Witek; Riek, Roland

    2003-01-01

    The paper presents an alternative technique for chemical shift monitoring in a multi-dimensional NMR experiment. The monitored chemical shift is coded in the line-shape of a cross-peak through an apparent residual scalar coupling active during an established evolution period or acquisition. The size of the apparent scalar coupling is manipulated with an off-resonance radio-frequency pulse in order to correlate the size of the coupling with the position of the additional chemical shift. The strength of this concept is that chemical shift information is added without an additional evolution period and accompanying polarization transfer periods. This concept was incorporated into the three-dimensional triple-resonance experiment HNCA, adding the information of 1 H α chemical shifts. The experiment is called HNCA coded HA, since the chemical shift of 1 H α is coded in the line-shape of the cross-peak along the 13 C α dimension

  8. Rooted triple consensus and anomalous gene trees

    Directory of Open Access Journals (Sweden)

    Schmidt Heiko A

    2008-04-01

    Full Text Available Abstract Background Anomalous gene trees (AGTs are gene trees with a topology different from a species tree that are more probable to observe than congruent gene trees. In this paper we propose a rooted triple approach to finding the correct species tree in the presence of AGTs. Results Based on simulated data we show that our method outperforms the extended majority rule consensus strategy, while still resolving the species tree. Applying both methods to a metazoan data set of 216 genes, we tested whether AGTs substantially interfere with the reconstruction of the metazoan phylogeny. Conclusion Evidence of AGTs was not found in this data set, suggesting that erroneously reconstructed gene trees are the most significant challenge in the reconstruction of phylogenetic relationships among species with current data. The new method does however rule out the erroneous reconstruction of deep or poorly resolved splits in the presence of lineage sorting.

  9. Radiation sterilization of triple sugar iron agar

    International Nuclear Information System (INIS)

    Altmann, G.; Eisenberg, E.; Bogokowsky, B.

    1979-01-01

    Triple sugar iron agar (TSI), a medium used for the identification of enteric bacteria, was sterilized by gamma radiation using radiation doses of 750-2000 krad. The radio-sterilized medium, slightly modified by increasing its Phenol Red content, performed well when tested with different enterobacteriaceae and other gram negative bacteria. Growth, change of indicator reaction in slant and butt and formation of gas and H 2 S were equal in irradiated and autoclaved TSI. Slants of irradiated TSI in stoppered plastic tubes kept their diagnostic properties during storage for at least 4 months. Gamma irradiation appears to be an attractive and economical method of sterilising nutrient media in sealed tubes or other containers, avoiding the risk of contamination during processing. (author)

  10. Triple-layer smart grid business model

    DEFF Research Database (Denmark)

    Ma, Zheng; Lundgaard, Morten; Jørgensen, Bo Nørregaard

    2016-01-01

    Viewing the smart grid with the theory of business models may open opportunities in understanding and capturing values in new markets. This study tries to discover and map the smart grid ecosystem-based business model framework with two different environments (sub-Saharan Africa and Denmark......), and identifies the parameters for the smart grid solutions to the emerging markets. This study develops a triple-layer business model including the organizational (Niche), environmental (Intermediate), and global (Dominators) factors. The result uncovers an interface of market factors and stakeholders...... in a generic smart grid constellation. The findings contribute the transferability potential of the smart grid solutions between countries, and indicate the potential to export and import smart grid solutions based on the business modeling....

  11. Polarized triple-axis spectrometer TASP

    Energy Technology Data Exchange (ETDEWEB)

    Boeni, P; Keller, P [Lab. for Neutron Scattering ETH Zurich, Zurich (Switzerland) and Paul Scherrer Institute, Villigen (Switzerland)

    1996-11-01

    The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

  12. About the Triple A. Argentina 1973 - 1976

    OpenAIRE

    Rostica, Julieta

    2011-01-01

    El 25 de mayo de 1973 el peronismo volvió a gobernar la Argentina tras aproximadamente dos décadas de proscripción y persecución política. Tras su establecimiento, ciertos crímenes comenzaron a ser firmados con “AAA”. La Triple A tuvo la particularidad de desaparecer con el golpe de Estado del 24 de marzo de 1976. ¿Por qué esta organización sólo pudo existir en una democracia erigida en medio de dos dictaduras militares? ¿Por qué existió durante el tan anhelado gobierno peronista? El artículo...

  13. Triple negative breast cancer: an Indian perspective

    Directory of Open Access Journals (Sweden)

    Akhtar M

    2015-08-01

    Full Text Available Murtaza Akhtar, Subhrajit Dasgupta, Murtuza Rangwala Department of Surgery, NKP Salve Institute of Medical Sciences and Research Centre, Nagpur, Maharashtra, India Introduction: Breast cancer is the most common female cancer in the world. Triple negative breast cancer (TNBC is a recently identified biological variant with aggressive tumor behavior and poor prognosis. Data of hormonal status from the Indian population is scarce due to financial constraints in performing immunohistochemistry evaluation. The present study aims to prospectively analyze receptor status of all breast cancer patients and identify TNBC and compare their clinical profile and short term survival with other non-TNBC group. Materials and methods: All cytologically and histopathologically confirmed cases of carcinoma breast were prospectively enrolled. In a longitudinal study at tertiary care hospital in central India based on the hormonal status, they were further divided into TNBC and other groups. Comparison of risk factors, clinical profile and short-term survival was carried out. Results: A total 85 patients were enrolled and of them 37 (43.7% were TNBC. On comparing risk factors ie, age, age at menarche, total reproductive age, age at first child birth, and menopausal status – no statistical significance was observed between the TNBC and non-TNBC groups. But on comparison of clinical profile TNBC tumors were significantly large with majority of patients presenting as locally advanced breast cancer (83%. No statistical difference was observed in axillary lymph node status between two groups. TNBC tumors were histologically more aggressive (grade 3 compared to other groups. No statistically significant difference was observed in short term overall survival but all three deaths were observed in the TNBC group only and two local recurrences after surgery were observed in the TNBC group. Conclusion: TNBC forms a large proportion of carcinoma breast patients in a central

  14. Fractura triple del complejo suspensorio del hombro

    Directory of Open Access Journals (Sweden)

    Eraclio Delgado Rifá

    2015-06-01

    Full Text Available El complejo suspensorio del hombro es una estructura sumamente importante, compuesta por un anillo de huesos y tejidos blandos. Las lesiones aisladas de este complejo anatómico son frecuentes y no afectan su estabilidad. La interrupción doble conduce a la inestabilidad de esta estructura y usualmente requiere tratamiento quirúrgico. La triple interrupción, por su parte, es sumamente rara y es encontrada en casos de trauma de alta energía a menudo en asociación con otras lesiones. Se presenta una triple lesión del complejo suspensorio del hombro en un paciente de 46 años de edad, con una fractura de la glenoides, del acromion tipo III de Kuhn y de la coracoides tipo II de Ogawa. En este caso, la fractura del acromion fue tratada con fijación percutánea con alambres de Kirschner, por tener asociado lesiones de partes blandas que contraindicaron la reducción abierta. La fractura de la glenoides y de la apófisis coracoides fueron tratadas conservadoramente. Después de 6 meses de evolución, el paciente tuvo un resultado funcional aceptable, con una abducción de 90 grados, los 30 grados de rotación externa y 70 de rotación interna, además asintomático y consolidación de todas las fracturas. A pesar de ser catalogada de una lesión grave del cinturón escapular y estar asociada a otras lesiones se obtuvo un resultado satisfactorio al final del tratamiento.

  15. A Grounded Theory for Regional Development through the IT Offshoring Industry with the Triple-Helix Involvment

    Science.gov (United States)

    Villarreal de la Garza, Sonia

    2011-01-01

    The purpose of this qualitative grounded study was to explore the thoughts, experiences, and needs of potential clients and of the triple-helix members with the intention to establish a framework to support the development of the regional economy through the information technology (IT) and business processing outsourcing (BPO) offshoring industry.…

  16. New light on the Kr-(4p55s2) Feshbach resonances: high-resolution electron scattering experiments and B-spline R-matrix calculations

    International Nuclear Information System (INIS)

    Hoffmann, T H; Ruf, M-W; Hotop, H; Zatsarinny, O; Bartschat, K; Allan, M

    2010-01-01

    In a joint experimental and theoretical effort, we carried out a detailed study of electron scattering from Kr atoms in the energy range of the low-lying Kr - (4p 5 5s 2 ) Feshbach resonances. Absolute angle-differential cross sections for elastic electron scattering were measured over the energy range 9.3-10.3 eV with an energy width of about 13 meV at scattering angles between 10 deg. and 180 deg. Using several sets of elastic scattering phase shifts, a detailed analysis of the sharp Kr - (4p 5 5s 2 2 P 3/2 ) resonance was carried out, resulting in a resonance width of Γ 3/2 3.6(2) meV. By direct comparison with the position of the Ar - (3p 5 4s 2 2 P 3/2 ) resonance, the energy for the Kr - (4p 5 5s 2 2 P 3/2 ) resonance was determined as E 3/2 = 9.489(3) eV. A Fano-type fit of the higher lying Kr - (4p 5 5s 2 2 P 1/2 ) resonance yielded the resonance parameters Γ 1/2 = 33(5) meV and E 1/2 = 10.126(4) eV. In order to obtain additional insights, B-spline R-matrix calculations were performed for both the elastic and the inelastic cross sections above the threshold for 4p 5 5s excitation. They provide the total and angle-differential cross sections for excitation of long-lived and short-lived levels of the 4p 5 5s configuration in Kr and branching ratios for the decay of the Kr - (4p 5 5s 2 2 P 1/2 ) resonance into the three available exit channels. The results are compared with selected experimental data.

  17. Resonance charge exchange processes

    International Nuclear Information System (INIS)

    Duman, E.L.; Evseev, A.V.; Eletskij, A.V.; Radtsig, A.A.; Smirnov, B.M.

    1979-01-01

    The calculation results for the resonance charge exchange cross sections for positive and negative atomic and molecular ions are given. The calculations are performed on the basis of the asymptotic theory. The factors affecting the calculation accuracy are analysed. The calculation data for 28 systems are compared with the experiment

  18. Reconstruction and identification of muons in the experiment DO, study of the resonant production of s-leptons; Reconstruction et identification des muons dans l'experience DO etude de la production resonnante de s-leptons

    Energy Technology Data Exchange (ETDEWEB)

    Deliot, F

    2002-04-01

    In the framework of supersymmetric models with R-parity violation, supersymmetric particles can be singly produced. If the {lambda}'{sub 211} coupling is the dominant one, muon s-neutrino or a s-muon can be resonantly produced at the Tevatron and lead to tri-lepton (with two muons) or like sign dimuon final states. In this thesis, the discovery potential for these signals at Tevatron Run II has been studied in the framework of the minimal supergravity model. Those processes reach a high sensitivity on the model parameters m{sub 0} and m{sub 1/2} and allow to reconstruct the masses for the superparticles involved in the decay chain. Tevatron Run II has begun in 2001 after important upgrades in the accelerator complex and in the D0 experiment. In particular the muon spectrometer has been modified. The D0 experiment is in the calibration and alignment phase. The second part of the work presented in this thesis covers the muon reconstruction and identification. The track reconstruction in the muon spectrometer is performed with a fit taking into account magnetic field, energy loss and multiple scattering in the iron toroid. This method gives a momentum resolution limited for low momentum tracks at 20% due to multiple scattering in the toroid. These tracks and its error matrix are then propagated through the calorimeter and combined with the inner tracker tracks. The first Run II data recorded by D0 has allowed to compute the trigger efficiency and to valid the muon identification algorithms which were, for this thesis, entirely based on muon spectrometer informations. The first J/{psi} studies show that the reconstruction works correctly and that the identification criteria are preferment. (author)

  19. A PZT Actuated Triple-Finger Gripper for Multi-Target Micromanipulation

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2017-01-01

    Full Text Available This paper presents a triple-finger gripper driven by a piezoceramic (PZT transducer for multi-target micromanipulation. The gripper consists of three fingers assembled on adjustable pedestals with flexible hinges for a large adjustable range. Each finger has a PZT actuator, an amplifying structure, and a changeable end effector. The moving trajectories of single and double fingers were calculated and finite element analyses were performed to verify the reliability of the structures. In the gripping experiment, various end effectors of the fingers such as tungsten probes and fibers were tested, and different micro-objects such as glass hollow spheres and iron spheres with diameters ranging from 10 to 800 μm were picked and released. The output resolution is 145 nm/V, and the driven displacement range of the gripper is 43.4 μm. The PZT actuated triple-finger gripper has superior adaptability, high efficiency, and a low cost.

  20. Fast response of the optical nonlinearity in a GaAs/AlGaAs asymmetric triple quantum well structure

    CERN Document Server

    Ahn, S H; Sawaki, N

    1999-01-01

    The time response of the optical nonlinear behavior in a GaAs/AlGaAs asymmetric triple quantum well structure is estimated by using a picosecond pump-probe method at 77 K. From the results of the transmission of the probe pulse as a function of the delay time at the excitation wavelengths, a rise time of 5 approx 10 ps and a fall time of 8 approx 16 ps are obtained. The nonlinear behavior is attributed to the triple resonance of the electronic states due to the build-up of the internal field induced by the separation of photo-excited electrons and holes. It is found that the rise time is determined by the tunneling transfer time of the electrons in the narrowest well to an adjacent well separated by a thin potential barrier.

  1. Exploiting multicompartment effects in triple-echo steady-state T2 mapping for fat fraction quantification.

    Science.gov (United States)

    Liu, Dian; Steingoetter, Andreas; Curcic, Jelena; Kozerke, Sebastian

    2018-01-01

    To investigate and exploit the effect of intravoxel off-resonance compartments in the triple-echo steady-state (TESS) sequence without fat suppression for T 2 mapping and to leverage the results for fat fraction quantification. In multicompartment tissue, where at least one compartment is excited off-resonance, the total signal exhibits periodic modulations as a function of echo time (TE). Simulated multicompartment TESS signals were synthesized at various TEs. Fat emulsion phantoms were prepared and scanned at the same TE combinations using TESS. In vivo knee data were obtained with TESS to validate the simulations. The multicompartment effect was exploited for fat fraction quantification in the stomach by acquiring TESS signals at two TE combinations. Simulated and measured multicompartment signal intensities were in good agreement. Multicompartment effects caused erroneous T 2 offsets, even at low water-fat ratios. The choice of TE caused T 2 variations of as much as 28% in cartilage. The feasibility of fat fraction quantification to monitor the decrease of fat content in the stomach during digestion is demonstrated. Intravoxel off-resonance compartments are a confounding factor for T 2 quantification using TESS, causing errors that are dependent on the TE. At the same time, off-resonance effects may allow for efficient fat fraction mapping using steady-state imaging. Magn Reson Med 79:423-429, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. On Pythagoras Theorem for Products of Spectral Triples

    Science.gov (United States)

    D'Andrea, Francesco; Martinetti, Pierre

    2013-05-01

    We discuss a version of Pythagoras theorem in noncommutative geometry. Usual Pythagoras theorem can be formulated in terms of Connes' distance, between pure states, in the product of commutative spectral triples. We investigate the generalization to both non-pure states and arbitrary spectral triples. We show that Pythagoras theorem is replaced by some Pythagoras inequalities, that we prove for the product of arbitrary (i.e. non-necessarily commutative) spectral triples, assuming only some unitality condition. We show that these inequalities are optimal, and we provide non-unital counter-examples inspired by K-homology.

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  4. Design and construction of a triple-axis crystal neutron spectrometer and performance testing by means of measurements of dispersion relations in copper

    International Nuclear Information System (INIS)

    Fuhrmann, C.

    1979-01-01

    The Triple-Axis Crystal Neutron Spectrometer is the best instrument for the study of lattice dynamics, when the neutron inelastic scattering technique is used. Design, construction and operation of a triple-axis crystal neutron spectrometer, whose construction was recently finished at IEA are described. The design principles employed are directed to mechanical simplicity, facility of construction and flexibility in operation, with no adapted components to industrial applications were used in the construction. The operational characteristics of the spectrometer, such as the neutron wavelenght of the incoming beam and the resolution have been determined. With the purpose to check the performance of IEA Triple-Axis Crystal Neutron Spectrometer, dispersion relation curves for copper, at room temperature, have been measured. The frequency of phonons propagating along three major symmetry directions have been determined. The measurements were carried out operating the Triple-Axis Spectrometer in the 'sup(→)Q-constant' mode. An excelent agreement could be observed between the results obtained in the present experiment and the data for copper presented in the literature. This comparison indicates that the IEA Triple-Axis Crystal Neutron Spectrometer is in good operational conditions and is able to perform original experiments. Details on the experimental procedures for the case of a Triple-Axis Spectrometer operating in 'sup(→)Q-constant' mode are also presented. (Author) [pt

  5. Resonant freak microwaves

    International Nuclear Information System (INIS)

    Aguiar, F.M. de

    2011-01-01

    The Helmholtz equation describing transverse magnetic modes in a closed flat microwave resonator with 60 randomly distributed discs is numerically solved. At lower frequencies, the calculated wave intensity spatially distributed obeys the universal Porter-Thomas form if localized modes are excluded. A superposition of resonant modes is shown to lead to rare events of extreme intensities (freak waves) at localized 'hot spots'. The temporally distributed intensity of such a superposition at the center of a hot spot also follows the Porter-Thomas form. Branched modes are found at higher frequencies. The results bear resemblance to recent experiments reported in an open cavity.

  6. Hadronic Resonances from STAR

    Directory of Open Access Journals (Sweden)

    Wada Masayuki

    2012-11-01

    Full Text Available The results of resonance particle productions (ρ0, ω, K*, ϕ, Σ*, and Λ* measured by the STAR collaboration at RHIC from various colliding systems and energies are presented. Measured mass, width, 〈pT〉, and yield of those resonances are reviewed. No significant mass shifts or width broadening beyond the experiment uncertainties are observed. New measurements of ϕ and ω from leptonic decay channels are presented. The yields from leptonic decay channels are compared with the measurements from hadronic decay channels and the two results are consistent with each other.

  7. Electromagnetic resonance waves. Resonancias de ondas electromagneticas

    Energy Technology Data Exchange (ETDEWEB)

    Villaba, J.M.; Manjon, F.J.; Guirao, A.; Andres, M.V.

    1994-01-01

    We describe in this paper a set of experiments designed to make qualitative and quantitative measurements on electromagnetic resonances of several simple systems. The experiments are designed for the undergraduate laboratory of Electricity and Magnetism in Physics. These experiments can help the students understanding the concept of resonance, which appears in different fields of Physics. (Author) 8 refs.

  8. Hermitian (ϵ,δ)-Freudenthal-Kantor Triple Systems and Certain Applications of *-Generalized Jordan Triple Systems to Field Theory

    International Nuclear Information System (INIS)

    Kamiya, Noriaki; Sato, Matsuo

    2014-01-01

    We define Hermitian (ϵ,δ)-Freudenthal-Kantor triple systems and prove a structure theorem. We also give some examples of triple systems that are generalizations of the u(N)⊕u(M) and sp(2N)⊕u(1) Hermitian 3-algebras. We apply a *-generalized Jordan triple system to a field theory and obtain a Chern-Simons gauge theory. We find that the novel Higgs mechanism works, where the Chern-Simons gauge theory reduces to a Yang-Mills theory in a certain limit

  9. Applications of tripled chaotic maps in cryptography

    International Nuclear Information System (INIS)

    Behnia, S.; Akhshani, A.; Akhavan, A.; Mahmodi, H.

    2009-01-01

    Security of information has become a major issue during the last decades. New algorithms based on chaotic maps were suggested for protection of different types of multimedia data, especially digital images and videos in this period. However, many of them fundamentally were flawed by a lack of robustness and security. For getting higher security and higher complexity, in the current paper, we introduce a new kind of symmetric key block cipher algorithm that is based on tripled chaotic maps. In this algorithm, the utilization of two coupling parameters, as well as the increased complexity of the cryptosystem, make a contribution to the development of cryptosystem with higher security. In order to increase the security of the proposed algorithm, the size of key space and the computational complexity of the coupling parameters should be increased as well. Both the theoretical and experimental results state that the proposed algorithm has many capabilities such as acceptable speed and complexity in the algorithm due to the existence of two coupling parameters and high security. Note that the ciphertext has a flat distribution and has the same size as the plaintext. Therefore, it is suitable for practical use in secure communications.

  10. Triple Isotope Water Analyzer for Extraplanetary Studies, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research (LGR) proposes to employ Off-Axis ICOS to develop triple-isotope water analyzers for lunar and other extraplanetary exploration. This instrument...

  11. Uncovering the triple omeron vertex from Wilson line formalism

    International Nuclear Information System (INIS)

    Chirilli, G. A.; Szymanowski, L.; Wallon, S.

    2011-01-01

    We compute the triple omeron vertex from the Wilson line formalism, including both planar and nonplanar contributions, and get perfect agreement with the result obtained in the Extended Generalized Logarithmic Approximation based on Reggeon calculus.

  12. Tripled Fixed Point in Ordered Multiplicative Metric Spaces

    Directory of Open Access Journals (Sweden)

    Laishram Shanjit

    2017-06-01

    Full Text Available In this paper, we present some triple fixed point theorems in partially ordered multiplicative metric spaces depended on another function. Our results generalise the results of [6] and [5].

  13. Review of 241 Pu resonance parameters

    International Nuclear Information System (INIS)

    Derrien, H.

    1981-10-01

    The status of 241 Pu resonance parameters is reviewed. The most important recent results are compared in some energy ranges, both from single level and multilevel point of view. It appears that an accurate set of resonance parameters is not still obtained for a general description of the cross-sections in the resonance region. Some recommendations are given for further experiments or evaluations

  14. Triple-membrane reduces need for ion exchange regeneration

    International Nuclear Information System (INIS)

    Valcour, H.

    1989-01-01

    Triple-membrane water treatment systems are comprised of ultrafiltration units for pretreatment, electrodialysis reversal primary demineralizers, reverse osmosis secondary demineralizers, portable ion exchange unit polishing demineralizers, and ultraviolet sterilizers. The triple-membrane process is designed to provide an unprecedented degree of pretreatment to maximize efficiency, durability and reliability of the reverse osmosis, whilst reducing the required regeneration frequency of the ion exchange demineralizer by one to two orders of magnitude. (author)

  15. Modified Genta triple stain for identifying Helicobacter pylori.

    OpenAIRE

    el-Zimaity, H M; Wu, J; Graham, D Y

    1999-01-01

    AIM: To evaluate whether lead nitrate could replace uranyl nitrate in the Genta stain for H pylori without sacrificing the advantages of the triple stain (Steiner silver impregnation combined with Alcian blue and haematoxylin/eosin (H&E)). METHODS: A comparison was made in 16 specimens between the original triple stain and the revised version. One pathologist evaluated all sections. RESULTS: Direct substitution of lead nitrate for uranium nitrate produced well stained organisms without interf...

  16. Immunohistochemical Characteristics of Triple Negative/Basal-like Breast Cancer

    OpenAIRE

    Emel Ebru PALA; Ümit BAYOL; Süheyla CUMURCU; Elif KESKİN

    2012-01-01

    Objective: Triple-negative-breast-cancer that accounts for 10-20% of all breast carcinomas is defined by the lack of estrogen receptor, progesterone receptor, HER2 expression, and agressive clinical behavior. Triple-negative-breast-cancer is categorized into basal like and other types. The basal-like subtype is characterized by the expression of myoepithelial/basal markers.Material and Method: We studied 41 immunohistochemically triplenegative- breast-cancer patients to determine EGFR, Cytoke...

  17. Targeting Prolyl Peptidases in Triple-Negative Breast Cancer

    Science.gov (United States)

    2017-02-01

    ABSTRACT Triple negative breast cancer (TNBC) is an aggressive sub-type with limited treatment options and poor prognosis. The most life -threatening... negative feedback loops within the pathway limit their effectiveness . For example, AKT inhibitors cause increased expression of IGF1R/ErbB3 and, as a...AWARD NUMBER: W81XWH-16-1-0025 TITLE: Targeting Prolyl Peptidases in Triple- Negative Breast Cancer PRINCIPAL INVESTIGATOR: Carl G. Maki, PhD

  18. Single, double, and triple quantum dots in the transport; Einzel-, Doppel- und Dreifachquantenpunkte im Transport

    Energy Technology Data Exchange (ETDEWEB)

    Rogge, Maximilian Christoph

    2008-12-03

    This thesis describes the fabrication of different lateral single, double and triple quantum dots as well as the investigation of these devices with electronic transport. Based on GaAs/AlGaAs heterostructures, the fabrication was carried out using optical lithography and lithography with a scanning electron microscope and an atomic force microscope. The latter ones were also used in combination. Aside from basic effects like Coulomb blockade the analysis of single quantum dots particularly yielded results by charge detection and magneto transport. With charge detection using quantum point contacts conclusions were attained concerning tunneling rates and the extension of wave functions. In a magnetic field the influence of the electronic spin is important aside from aspects concerning the Fock-Darwin spectrum. Analyses were performed on Zeeman effect, spin pairing, spin blockade and Kondo effect. The combination of spin blockade and Kondo effect allows statements concerning the spin configuration, which depends on the electron number. With double quantum dots of different geometries the two mechanisms of capacitive coupling and tunnel coupling were analyzed. They were found in spectra of ground and excited states. With gate voltage and magnetic field it was possible to freely vary character and strength of coupling. With capacitive coupling, spin blockade was investigated again. The analysis of coupling effects was performed using transport and charge measurements. Aside from results on tunneling rates the latter one allows to detect molecular states. Concerning triple quantum dots the three dimensional stability diagram was analyzed. The free variation of energies of all three dots was achieved. The evolution of resonances was observed with transport and charge detection. With a starlike device geometry it was possible to perform two-path measurements. They provide a new measurand, the distinguishability of double and triple dot physics. (orig.)

  19. Multiquark Resonances

    CERN Document Server

    Esposito, A.; Polosa, A.D.

    2016-01-01

    Multiquark resonances are undoubtedly experimentally observed. The number of states and the amount of details on their properties has been growing over the years. It is very recent the discovery of two pentaquarks and the confirmation of four tetraquarks, two of which had not been observed before. We mainly review the theoretical understanding of this sector of particle physics phenomenology and present some considerations attempting a coherent description of the so called X and Z resonances. The prominent problems plaguing theoretical models, like the absence of selection rules limiting the number of states predicted, motivate new directions in model building. Data are reviewed going through all of the observed resonances with particular attention to their common features and the purpose of providing a starting point to further research.

  20. Neuroaesthetic Resonance

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2013-01-01

    Neuroaesthetic Resonance emerged from a mature body of patient- centered gesture-control research investigating non-formal rehabilitation via ICT-enhanced-Art to question ‘Aesthetic Resonance’. Motivating participation, ludic engagement, and augmenting physical motion in non-formal (fun) treatment...... sessions are achieved via adaptive action-analyzed activities. These interactive virtual environments are designed to empower patients’ creative and/or playful expressions via digital feedback stimuli. Unconscious self- pushing of limits result from innate distractive mechanisms offered by the alternative...... the unencumbered motion-to-computer-generated activities - ‘Music Making’, ‘Painting’, ‘Robotic’ and ‘Video Game’ control. A focus of this position paper is to highlight how Aesthetic Resonance, in this context, relates to the growing body of research on Neuroaesthetics to evolve Neuroaesthetic Resonance....

  1. Warps, grids and curvature in triple vector bundles

    Science.gov (United States)

    Flari, Magdalini K.; Mackenzie, Kirill

    2018-06-01

    A triple vector bundle is a cube of vector bundle structures which commute in the (strict) categorical sense. A grid in a triple vector bundle is a collection of sections of each bundle structure with certain linearity properties. A grid provides two routes around each face of the triple vector bundle, and six routes from the base manifold to the total manifold; the warps measure the lack of commutativity of these routes. In this paper we first prove that the sum of the warps in a triple vector bundle is zero. The proof we give is intrinsic and, we believe, clearer than the proof using decompositions given earlier by one of us. We apply this result to the triple tangent bundle T^3M of a manifold and deduce (as earlier) the Jacobi identity. We further apply the result to the triple vector bundle T^2A for a vector bundle A using a connection in A to define a grid in T^2A . In this case the curvature emerges from the warp theorem.

  2. Crystallographic and Electronic Structure of the Sr3Sb2CoO9 Triple Perovskite

    International Nuclear Information System (INIS)

    González, W; Téllez, D A Landínez; Roa-Rojas, J; Cardona, R

    2014-01-01

    Compounds The perovskites are materials with physical and chemical characteristics that make them optimal for application in the technological and scientist. When the ideal formula of perovskite ABO 3 is modified by introducing a special structural arrangement can get to get triple perovskites, which correspond to the formula A 3 B 2 B'O 9 . In this work we report the synthesis process and the study of electronic structure and crystal Sr 3 Sb 2 CoO 9 new triple perovskite. From the experiments of X-ray Diffraction and the application of the Rietveld refinement method was revealed that the system crystallizes in a perovskite structure with a characteristic triple given by the space group Immm (#71) and lattice parameters a=9.791(9) Å, b=5.656(7) Å and c=16.957(8) Å. Ab initio calculations of density of states (DOS) and electronic structure were carried out for this perovskite-like system by using the Quantum EXPRESSO code. The exchange-correlation potential was treated using the Generalized Gradient Approximation (GGA). All calculations were carried-out using spin polarization.

  3. Resonant enhancement in leptogenesis

    Science.gov (United States)

    Dev, P. S. B.; Garny, M.; Klaric, J.; Millington, P.; Teresi, D.

    2018-02-01

    Vanilla leptogenesis within the type I seesaw framework requires the mass scale of the right-handed neutrinos to be above 109 GeV. This lower bound can be avoided if at least two of the sterile states are almost mass degenerate, which leads to an enhancement of the decay asymmetry. Leptogenesis models that can be tested in current and upcoming experiments often rely on this resonant enhancement, and a systematic and consistent description is therefore necessary for phenomenological applications. In this paper, we give an overview of different methods that have been used to study the saturation of the resonant enhancement when the mass difference becomes comparable to the characteristic width of the Majorana neutrinos. In this limit, coherent flavor transitions start to play a decisive role, and off-diagonal correlations in flavor space have to be taken into account. We compare various formalisms that have been used to describe the resonant regime and discuss under which circumstances the resonant enhancement can be captured by simplified expressions for the CP asymmetry. Finally, we briefly review some of the phenomenological aspects of resonant leptogenesis.

  4. Algorithm of resonance orders for the objects

    Science.gov (United States)

    Zhang, YongGang; Zhang, JianXue

    2018-03-01

    In mechanical engineering, the object resonance phenomena often occur when the external incident wave frequency is close to object of the natural frequency. Object resonance phenomena get the maximum value when the external incident frequency is equal to object the natural frequency. Experiments found that resonance intension of the object is changed, different objects resonance phenomena present different characteristics of ladders. Based on object orders resonance characteristics, the calculation method of object orders resonance is put forward in the paper, and the application for the light and sound waves on the seven order resonance characteristics by people feel, the result error is less than 1%.Visible in this paper, the method has high accuracy and usability. The calculation method reveals that some object resonance occur present order characteristic only four types, namely the first-orders resonance characteristics, third-orders characteristics, five orders characteristic, and seven orders characteristic.

  5. Accurate computer-aided quantification of left ventricular parameters : experience in 1555 cardiac magnetic resonance studies from the Framingham Heart Study

    NARCIS (Netherlands)

    Hautvast, G.L.T.F.; Salton, C.J.; Chuang, M.L.; Breeuwer, M.; O'Donnel, C.J.; Manning, W.J.

    2011-01-01

    Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases.

  6. MAGNETIC-RESONANCE-IMAGING USING A CLINICAL WHOLE-BODY SYSTEM - AN INTRODUCTION TO A USEFUL TECHNIQUE IN SMALL ANIMAL-EXPERIMENTS

    NARCIS (Netherlands)

    WOLF, RFE; LAM, KH; MOOYAART, EL; BLEICHRODT, RP; NIEUWENHUIS, P; SCHAKENRAAD, JM

    A clinical whole body magnetic resonance imaging (MRI) system with high resolution coils was used to obtain non-invasive images of the living rat. The results demonstrate the feasibility of the set-up and the advantages of this new imaging technique: detailed information, no extra costs,

  7. A CPW-fed Triple-band Antenna for WLAN and WiMAX Applications

    Directory of Open Access Journals (Sweden)

    X.L.Yang

    2014-12-01

    Full Text Available In this letter, a compact printed antenna fed by coplanar waveguide for triple-band is presented. The proposed antenna consists of two rectangular metallic loops in front and a slit square ring on the backside. Tri-band has been achieved, which can be easily tuned by adjusting the sizes of the rectangles. An analysis of equal lumped circuit mechanism as well the triple band operation is provided. Key parameters to tune the resonant frequencies have been identified. The overall dimension of the proposed antenna is 30×26 mm^2. Simulated results show that the presented antenna can cover three separated impedance bandwidths of ~13% at 300 MHz (2.2–2.5 GHz, ~14% at 500 MHz (3.3–3.8 GHz, and ~15% at 800 MHz (5.1–5.9 GHz, which are well applied for both 2.4/5.2/5.8-GHz WLAN bands and 3.5/5.5-GHz WiMAX bands.

  8. 996 RESONANCE November 2013

    Indian Academy of Sciences (India)

    IAS Admin

    996. RESONANCE. November 2013. Page 2. 997. RESONANCE. November 2013. Page 3. 998. RESONANCE. November 2013. Page 4. 999. RESONANCE. November 2013. Page 5. 1000. RESONANCE. November 2013. Page 6. 1001. RESONANCE. November 2013. Page 7. 1002. RESONANCE. November 2013 ...

  9. 817 RESONANCE September 2013

    Indian Academy of Sciences (India)

    IAS Admin

    817. RESONANCE ⎜ September 2013. Page 2. 818. RESONANCE ⎜ September 2013. Page 3. 819. RESONANCE ⎜ September 2013. Page 4. 820. RESONANCE ⎜ September 2013. Page 5. 821. RESONANCE ⎜ September 2013. Page 6. 822. RESONANCE ⎜ September 2013. Page 7. 823. RESONANCE ⎜ September ...

  10. 369 RESONANCE April 2016

    Indian Academy of Sciences (India)

    IAS Admin

    369. RESONANCE ⎜ April 2016. Page 2. 370. RESONANCE ⎜ April 2016. Page 3. 371. RESONANCE ⎜ April 2016. Page 4. 372. RESONANCE ⎜ April 2016. Page 5. 373. RESONANCE ⎜ April 2016. Page 6. 374. RESONANCE ⎜ April 2016. Page 7. 375. RESONANCE ⎜ April 2016.

  11. Ultra-Thin Multi-Band Polarization-Insensitive Microwave Metamaterial Absorber Based on Multiple-Order Responses Using a Single Resonator Structure

    Directory of Open Access Journals (Sweden)

    Yong Zhi Cheng

    2017-10-01

    Full Text Available We design an ultra-thin multi-band polarization-insensitive metamaterial absorber (MMA using a single circular sector resonator (CSR structure in the microwave region. Simulated results show that the proposed MMA has three distinctive absorption peaks at 3.35 GHz, 8.65 GHz, and 12.44 GHz, with absorbance of 98.8%, 99.7%, and 98.3%, respectively, which agree well with an experiment. Simulated surface current distributions of the unit-cell structure reveal that the triple-band absorption mainly originates from multiple-harmonic magnetic resonance. The proposed triple-band MMA can remain at a high absorption level for all polarization of both transverse-electric (TE and transverse-magnetic (TM modes under normal incidence. Moreover, by further optimizing the geometric parameters of the CSRs, four-band and five-band MMAs can also be obtained. Thus, our design will have potential application in detection, sensing, and stealth technology.

  12. The triple-A supply chain.

    Science.gov (United States)

    Lee, Hau L

    2004-10-01

    Building a strong supply chain is essential for business success. But when it comes to improving their supply chains, few companies take the right approach. Many businesses work to make their chains faster or more cost-effective, assuming that those steps are the keys to competitive advantage. To the contrary: Supply chains that focus on speed and costs tend to deteriorate over time. The author has spent 15 years studying more than 60 companies to gain insight into this and other supply chain dilemmas. His conclusion: Only companies that build supply chains that are agile, adaptable, and aligned get ahead of their rivals. All three components are essential; without any one of them, supply chains break down. Great companies create supply chains that respond to abrupt changes in markets. Agility is critical because in most industries, both demand and supply fluctuate rapidly and widely. Supply chains typically cope by playing speed against costs, but agile ones respond both quickly and cost-efficiently. Great companies also adapt their supply networks when markets or strategies change. The best supply chains allow managers to identify structural shifts early by recording the latest data, filtering out noise, and tracking key patterns. Finally, great companies align the interests of the partners in their supply chains with their own. That's important because every firm is concerned solely with its own interests. If its goals are out of alignment with those of other partners in the supply chain, performance will suffer. When companies hear about the triple-A supply chain, they assume that building one will require increased technology and investment. But most firms already have the infrastructure in place to create one. A fresh attitude alone can go a long way toward making it happen.

  13. Autostereogram resonators

    Science.gov (United States)

    Leavey, Sean; Rae, Katherine; Murray, Adam; Courtial, Johannes

    2012-09-01

    Autostereograms, or "Magic Eye" pictures, are repeating patterns designed to give the illusion of depth. Here we discuss optical resonators that create light patterns which, when viewed from a suitable position by a monocular observer, are autostereograms of the three-dimensional shape of one of the mirror surfaces.

  14. Amplitude saturation of MEMS resonators explained by autoparametric resonance

    International Nuclear Information System (INIS)

    Van der Avoort, C; Bontemps, J J M; Steeneken, P G; Le Phan, K; Van Beek, J T M; Van der Hout, R; Hulshof, J; Fey, R H B

    2010-01-01

    This paper describes a phenomenon that limits the power handling of MEMS resonators. It is observed that above a certain driving level, the resonance amplitude becomes independent of the driving level. In contrast to previous studies of power handling of MEMS resonators, it is found that this amplitude saturation cannot be explained by nonlinear terms in the spring constant or electrostatic force. Instead we show that the amplitude in our experiments is limited by nonlinear terms in the equation of motion which couple the in-plane length-extensional resonance mode to one or more out-of-plane (OOP) bending modes. We present experimental evidence for the autoparametric excitation of these OOP modes using a vibrometer. The measurements are compared to a model that can be used to predict a power-handling limit for MEMS resonators

  15. Amplitude saturation of MEMS resonators explained by autoparametric resonance

    Energy Technology Data Exchange (ETDEWEB)

    Van der Avoort, C; Bontemps, J J M; Steeneken, P G; Le Phan, K; Van Beek, J T M [NXP Research, Eindhoven (Netherlands); Van der Hout, R; Hulshof, J [Department of Mathematics, VU University—Faculty of Sciences, De Boelelaan 1081a, 1081 HV Amsterdam (Netherlands); Fey, R H B, E-mail: cas.van.der.avoort@nxp.com [Department of Mechanical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB, Eindhoven (Netherlands)

    2010-10-15

    This paper describes a phenomenon that limits the power handling of MEMS resonators. It is observed that above a certain driving level, the resonance amplitude becomes independent of the driving level. In contrast to previous studies of power handling of MEMS resonators, it is found that this amplitude saturation cannot be explained by nonlinear terms in the spring constant or electrostatic force. Instead we show that the amplitude in our experiments is limited by nonlinear terms in the equation of motion which couple the in-plane length-extensional resonance mode to one or more out-of-plane (OOP) bending modes. We present experimental evidence for the autoparametric excitation of these OOP modes using a vibrometer. The measurements are compared to a model that can be used to predict a power-handling limit for MEMS resonators.

  16. Cyclotron resonance for electrons over helium in resonator

    CERN Document Server

    Shikin, V B

    2002-01-01

    The problem on the cyclotron resonance (CR) for electrons on the helium film, positioned in the resonator lower part, is solved. It is shown, that it relates to one of the examples of the known problem on the oscillations of the coupled oscillators system. The coupling constant between these oscillators constituting the variable function of the problem parameters. It is minimal in the zero magnetic field and reaches its maximum under the resonance conditions, when the cyclotron frequency coincides with one of the resonator modes. The CR details of the Uhf CR-energy absorption coupled by the electrons + resonator system, are calculated. The applications of the obtained results to the available CR experiments for electrons over helium

  17. A Triple-Loop Inductive Power Transmission System for Biomedical Applications.

    Science.gov (United States)

    Lee, Byunghun; Kiani, Mehdi; Ghovanloo, Maysam

    2016-02-01

    A triple-loop wireless power transmission (WPT) system equipped with closed-loop global power control, adaptive transmitter (Tx) resonance compensation (TRC), and automatic receiver (Rx) resonance tuning (ART) is presented. This system not only opposes coupling and load variations but also compensates for changes in the environment surrounding the inductive link to enhance power transfer efficiency (PTE) in applications such as implantable medical devices (IMDs). The Tx was built around a commercial off-the-shelf (COTS) radio-frequency identification (RFID) reader, operating at 13.56 MHz. A local Tx loop finds the optimal capacitance in parallel with the Tx coil by adjusting a varactor. A global power control loop maintains the received power at a desired level in the presence of changes in coupling distance, coil misalignments, and loading. Moreover, a local Rx loop is implemented inside a power management integrated circuit (PMIC) to avoid PTE degradation due to the Rx coil surrounding environment and process variations. The PMIC was fabricated in a 0.35- μm 4M2P standard CMOS process with 2.54 mm(2) active area. Measurement results show that the proposed triple-loop system improves the overall PTE by up to 10.5% and 4.7% compared to a similar open- and single closed-loop system, respectively, at nominal coil distance of 2 cm. The added TRC and ART loops contribute 2.3% and 1.4% to the overall PTE of 13.5%, respectively. This is the first WPT system to include three loops to dynamically compensate for environment and circuit variations and improve the overall power efficiency all the way from the driver output in Tx to the load in Rx.

  18. Parallel image-acquisition in continuous-wave electron paramagnetic resonance imaging with a surface coil array: Proof-of-concept experiments

    Science.gov (United States)

    Enomoto, Ayano; Hirata, Hiroshi

    2014-02-01

    This article describes a feasibility study of parallel image-acquisition using a two-channel surface coil array in continuous-wave electron paramagnetic resonance (CW-EPR) imaging. Parallel EPR imaging was performed by multiplexing of EPR detection in the frequency domain. The parallel acquisition system consists of two surface coil resonators and radiofrequency (RF) bridges for EPR detection. To demonstrate the feasibility of this method of parallel image-acquisition with a surface coil array, three-dimensional EPR imaging was carried out using a tube phantom. Technical issues in the multiplexing method of EPR detection were also clarified. We found that degradation in the signal-to-noise ratio due to the interference of RF carriers is a key problem to be solved.

  19. Comparative study on mammography between triple negative and triple positive breast cancer

    International Nuclear Information System (INIS)

    Cui Chunxiao; Lin Qing; Yang Qing; Zhang Chuanyu; Wang Shaohua; Yu Hualong; Duan Feng; Liu Shihe

    2012-01-01

    Objective: To analyze the mammographic findings of triple-negative breast cancer [TNBC, which is estrogen receptor (ER) negative, progesterone receptor (PR) negative, and human epidermal growth factor receptor 2 (HER2) negative] and triple-positive breast cancer (TPBC, which is ER positive, PR positive, and HER2 positive), and to evaluate the relationship of immunohistochemologic receptor status and mammographic findings. Methods: The immunohistochemistry results of 631 cases with breast cancers were reviewed, including 117 cases of TNBC and 44 cases of TPBC. All of the patients took mammography at initial diagnosis. We retrospectively evaluated the visibility, morphology, distribution and size of the lesion (masses and calcifications) and breast density on mammography of TNBC, and compared them with those of TPBC. The age onset and tumor sizes of TNBC and TPBC were compared by using Chi-square test and t test. Results: The visibility rate of TNBC and TPBC on mammography were 88.0%(103/117) and 90.9% (40/44), and the difference between them was insignificant (χ 2 =0.055, P >0.05). TNBC was more frequently associated with merely a mass (56/103) than TPBC (12/40) (χ 2 =6.860, P<0.01), and the mean diameter of the mass of TNBC [(2.6 ± 1.4) cm] was larger than that of TPBC [(2.0 ± 0.6) cm] (t=2.087, P<0.05). TNBC were less frequently associated with microcalcifications (37/103) than TPBC (24/40) (χ 2 =7.423, P<0.01). Mammographic density and lesion visibility were similar between the two different immunophenotypes of breast cancers. The mean age of TNBC (52±9) was more than that of TPBC (48 ±8) (t=2.759, P<0.01). Infiltrating ductal carcinoma was the main pathologic type of both groups. Basal-like breast cancer accounted for 49% (57/117) of TNBC while none happened in TPBC. Conclusions: TNBC shows merely a mass with indistinct margins,lager size and is less associated with microcalcifications. These mammographic features might be useful in diagnosing triple

  20. The interface of mental health and human rights in Indigenous peoples: triple jeopardy and triple opportunity.

    Science.gov