  1. A tri-modality image fusion method for target delineation of brain tumors in radiotherapy.

    Directory of Open Access Journals (Sweden)

    Lu Guo

    Full Text Available To develop a tri-modality image fusion method for better target delineation in image-guided radiotherapy for patients with brain tumors.A new method of tri-modality image fusion was developed, which can fuse and display all image sets in one panel and one operation. And a feasibility study in gross tumor volume (GTV delineation using data from three patients with brain tumors was conducted, which included images of simulation CT, MRI, and 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET examinations before radiotherapy. Tri-modality image fusion was implemented after image registrations of CT+PET and CT+MRI, and the transparency weight of each modality could be adjusted and set by users. Three radiation oncologists delineated GTVs for all patients using dual-modality (MRI/CT and tri-modality (MRI/CT/PET image fusion respectively. Inter-observer variation was assessed by the coefficient of variation (COV, the average distance between surface and centroid (ADSC, and the local standard deviation (SDlocal. Analysis of COV was also performed to evaluate intra-observer volume variation.The inter-observer variation analysis showed that, the mean COV was 0.14(± 0.09 and 0.07(± 0.01 for dual-modality and tri-modality respectively; the standard deviation of ADSC was significantly reduced (p<0.05 with tri-modality; SDlocal averaged over median GTV surface was reduced in patient 2 (from 0.57 cm to 0.39 cm and patient 3 (from 0.42 cm to 0.36 cm with the new method. The intra-observer volume variation was also significantly reduced (p = 0.00 with the tri-modality method as compared with using the dual-modality method.With the new tri-modality image fusion method smaller inter- and intra-observer variation in GTV definition for the brain tumors can be achieved, which improves the consistency and accuracy for target delineation in individualized radiotherapy.

  2. Patterns and predictors of failure following tri-modality therapy for locally advanced esophageal cancer.

    Science.gov (United States)

    Shaikh, Talha; Zaki, Mark A; Dominello, Michael M; Handorf, Elizabeth; Konski, Andre A; Cohen, Steven J; Shields, Anthony; Philip, Philip; Meyer, Joshua E

    2016-01-01

    Although tri-modality therapy is an acceptable standard of care in patients with locally advanced esophageal cancer, data regarding patterns of failure is lacking. We report bi-institutional patterns of failure experience treating patients using tri-modality therapy. We retrospectively reviewed patients who underwent chemoradiation followed by esophagectomy between 2006 and 2011 at two NCI-designated cancer centers. First failure sites were categorized as local, regional nodal, or distant. Statistical analysis was performed using Fisher's exact test, non-parametric Wilcoxon rank-sum test, and multiple logistic regression. Kaplan-Meier curves were generated for relapse-free survival (RFS) and overall survival. A total of 132 patients met the inclusion criteria with a median age of 62 (range 36-80) and median follow-up of 28 months (range 4-128). There were a total of six (4.5%) local, 13 (10%) regional nodal, and 32 (23.5%) distant failures. Local failure was correlated with fewer lymph nodes (LN) assessed (p = 0.01) and close/positive margins (p 13 LN evaluated (p = 0.003). Distant recurrence was correlated with higher pathologic nodal stage (p < 0.001), ulceration (p = 0.017), perineural invasion (p = 0.029), residual disease (p = 0.004), and higher post-treatment PET SUV max (p = 0.049). Patients with a pathologic complete response (OR 0.19, 95% CI 0.05-0.68) were less likely to experience distant recurrence. Tumor and treatment factors may predict for failure in patients undergoing tri-modality therapy for locally advanced esophageal cancer. Further data is needed to identify patterns of failure in these patients.

  3. Tri-modal Person Re-identification with RGB, Depth and Thermal Features

    DEFF Research Database (Denmark)

    Møgelmose, Andreas; Bahnsen, Chris; Moeslund, Thomas B.

    2013-01-01

    Person re-identification is about recognizing people who have passed by a sensor earlier. Previous work is mainly based on RGB data, but in this work we for the first time present a system where we combine RGB, depth, and thermal data for re-identification purposes. First, from each of the three...... modalities, we obtain some particular features: from RGB data, we model color information from different regions of the body, from depth data, we compute different soft body biometrics, and from thermal data, we extract local structural information. Then, the three information types are combined in a joined...... classifier. The tri-modal system is evaluated on a new RGB-D-T dataset, showing successful results in re-identification scenarios....

  4. Small animal radiotherapy research platforms

    International Nuclear Information System (INIS)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-01-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  5. Small animal radiotherapy research platforms

    Energy Technology Data Exchange (ETDEWEB)

    Verhaegen, Frank; Granton, Patrick [Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Tryggestad, Erik, E-mail: frank.verhaegen@maastro.nl [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231 (United States)

    2011-06-21

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  6. Uni-, bi- and tri-modal warning signals : Effects of temporal parameters and sensory modality on perceived urgency

    NARCIS (Netherlands)

    Erp, J.B.F. van; Toet, A.; Janssen, J.B.

    2015-01-01

    Multi-sensory warnings can potentially enhance risk communication. Hereto we investigated how temporal signal parameters affect perceived urgency within and across modalities. In an experiment, 78 observers rated the perceived urgency of uni-, bi-, and/or tri-modal stimuli as function of 25

  7. Uni-, bi- and tri-modal warning signals: effects of temporal parameters and sensory modality on perceived urgency

    NARCIS (Netherlands)

    van Erp, Johannes Bernardus Fransiscus; Toet, Alexander; Janssen, Joris B.

    Multi-sensory warnings can potentially enhance risk communication. Hereto we investigated how temporal signal parameters affect perceived urgency within and across modalities. In an experiment, 78 observers rated the perceived urgency of uni-, bi-, and/or tri-modal stimuli as function of 25

  8. Small animal models of xenotransplantation.

    Science.gov (United States)

    Wang, Hao

    2012-01-01

    Organ transplantation has become a successful and acceptable treatment for end-stage organ failure. Such success has allowed transplant patients to resume a normal lifestyle. The demands for transplantation have been steadily increasing, as more patients and new diseases are being deemed eligible for treatment via transplantation. However, it is clear that human organs will never meet the increasing demand of transplantation. Therefore, scientists must continue to pursue alternative therapies and explore new treatments to meet the growing demand for the limited number of organs available. Transplanting organs from animals into humans (xenotransplantation) is one such therapy. The observed enthusiasm for xenotransplantation, irrespective of the severe shortage of human organs and tissues available for transplantation, can be said to stem from at least two factors. First, there is the possibility that animal organs and tissues might be less susceptible than those of humans to the recurrence of disease processes. Second, a xenograft might be used as a vehicle for introducing novel genes or biochemical processes which could be of therapeutic value for the transplant recipient.To date, millions of lives have been saved by organ transplantation. These remarkable achievements would have been impossible without experimental transplantation research in animal models. Presently, more than 95% of organ transplantation research projects are carried out using rodents, such as rats and mice. The key factor to ensure the success of these experiments lies in state-of-the art experimental surgery. Small animal models offer unique advantages for the mechanistic study of xenotransplantation rejection. Currently, multiple models have been developed for investigating the different stages of immunological barriers in xenotransplantation. In this chapter, we describe six valuable small animal models that have been used in xenotransplantation research. The methodology for the small animal

  9. Fluence compensated photoacoustic tomography in small animals (Conference Presentation)

    Science.gov (United States)

    Hussain, Altaf; Pool, Martin; Daoudi, Khalid; de Vries, Liesbeth G.; Steenbergen, Wiendelt

    2017-03-01

    Light fluence inside turbid media can be experimentally mapped by measuring ultrasonically modulated light (Acousto-optics). To demonstrate the feasibility of fluence corrected Photoacoustic (PA) imaging, we have realized a tri-modality (i.e. photoacoustic, acousto-optic and ultrasound) tomographic small animal imaging system. Wherein PA imaging provides high resolution map of absorbed optical energy density, Acousto-optics yields the fluence distribution map in the corresponding PA imaging plane and Ultrasound provides morphological information. Further, normalization of the PA image with the acousto-optically measured fluence map results in an image that directly represents the optical absorption. Human epidermal growth factor receptor 2 (HER2) is commonly found overexpressed in human cancers, among which breast cancers, resulting in a more aggressive tumor phenotype. Identification of HER2-expression is clinically relevant, because cancers overexpressing this marker are amenable to HER2-directed therapies, among which antibodies trastuzumab and pertuzumab. Here, we investigate the feasibility and advantage of acousto-optically assisted fluence compensated PA imaging over PA imaging alone in visualizing and quantifying HER2 expression. For this experiment, nude mice were xenografted with human breast cancer cell lines SKBR3 and BT474 (both HER2 overexpressing), as well as HER2-negative MDA-MB-231. To visualize HER2 expression in these mice, HER2 monoclonal antibody pertuzumab (Perjeta®, Roche), was conjugated to near-infrared dye IRDye 800CW (800CW, LICOR Biosciences) at a ratio of 1∶2 antibody to 800CW. When xenograft tumors measured ≥ 100 mm3, mice received 100 µg 800CW-pertuzumab intravenously. Three days post injection, mice were scanned for fluorescence signal with an IVIS scanner. After fluorescence scans, mice were euthanized and imaged in our PA tomographic imaging system.

  10. Neurological examination in small animals

    Directory of Open Access Journals (Sweden)

    Viktor Paluš

    2014-03-01

    Full Text Available This clinical review about the neurological examination in small animals describes the basics about the first steps of investigation when dealing with neurological patients. The knowledge of how to perform the neurological examination is important however more important is how to correctly interpret these performed tests. A step-by-step approach is mandatory and examiners should master the order and the style of performing these tests. Neurological conditions can be sometimes very distressing for owners and for pets that might not be the most cooperating. The role of a veterinary surgeon, as a professional, is therefore to collect the most relevant history, to examine a patient in a professional manner and to give to owners an educated opinion about the further treatment and prognosis. However neurological examinations might look challenging for many. But it is only the clinical application of neuroanatomy and neurophysiology to an every-day situation for practicing veterinarians and it does not require any specific in-to-depth knowledge. This clinical review is aimed not only to provide the information on how to perform the neurological examination but it is also aimed to appeal on veterinarians to challenge their daily routine and to start practicing on neurologically normal patients. This is the best and only way to differentiate between the normal and abnormal in a real situation.

  11. Small animal imaging. Basics and practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, Fabian [Aachen Univ. (RWTH) (Germany). Chair of Experimental Molecular Imaging; Pichler, Bernd J. (eds.) [Tuebingen Univ. (Germany). Lab. for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation

    2011-07-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  12. Small animal imaging. Basics and practical guide

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Pichler, Bernd J.

    2011-01-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  13. Antimicrobial stewardship in small animal veterinary practice

    DEFF Research Database (Denmark)

    Guardabassi, Luca; Prescott, John F

    2015-01-01

    Despite the increasing recognition of the critical role for antimicrobial stewardship in preventing the spread of multidrug-resistant bacteria, examples of effective antimicrobial stewardship programs are rare in small animal veterinary practice. This article highlights the basic requirements...... for establishing stewardship programs at the clinic level. The authors provide suggestions and approaches to overcome constraints and to move from theoretic concepts toward implementation of effective antimicrobial stewardship programs in small animal clinics....

  14. Advanced Small Animal Conformal Radiation Therapy Device.

    Science.gov (United States)

    Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J

    2017-02-01

    We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.

  15. [New drugs for small animals in 2016].

    Science.gov (United States)

    Emmerich, Ilka Ute

    2017-05-17

    In 2016, two active pharmaceutical ingredients were released on the German market for small animals: the mineralocorticoid Desoxycorticosterone (Zycortal ® ) and Sarolaner (Simparica ® ), an ectoparasiticide of the isoxazoline group. One substance has been authorized for an additional species; Fluralaner (Bravecto ® ), also an ectoparasiticide of the isoxazoline group, is now authorized for use in cats. Additionally, one veterinary drug with a new combination of active ingredients, one active substance in mono-preparation and two veterinary drugs with a new pharmaceutical form have been launched on the market for small animals.

  16. Clinical aspects of toxoplasmosis in small animal

    Directory of Open Access Journals (Sweden)

    André Luiz Baptista Galvão

    2014-02-01

    Full Text Available Toxoplasmosis, a zoonosis of worldwide distribution, has importance in human and veterinary medicine. Animals can be direct or indirect source of infection to man, and this intermediate host, the disease may be responsible for encephalitis and deaths due to congenital form as coinfection in neonates and patients with acquired immunodeficiency syndrome. The man and animals can acquire the disease by eating undercooked meat or cures, infected with tissue cysts, as well as food and water contaminated with oocysts. Iatrogenic, such as, blood transfusion and organ transplantation are other less frequent routes of transmission. The causative agent of this disease is Toxoplasma gondii, a protozoan obligate intracellular coccidian. In small animals, the infection has been reported in several countries, promoting varied clinical manifestations and uncommon but severe and fatal, which is a challenge in the clinical diagnosis of small animals, especially when the nervous system involvement. Thus, constitute the purpose of this review address the participation of small animals in the spread of the disease, clinical aspects related to it, as well as discuss methods of diagnosis, therapeutic measures, prophylaxis and control of this disease.

  17. Small animal cardiovascular MR imaging and spectroscopy

    NARCIS (Netherlands)

    Bakermans, Adrianus J.; Abdurrachim, Desiree; Moonen, Rik P. M.; Motaal, Abdallah G.; Prompers, Jeanine J.; Strijkers, Gustav J.; Vandoorne, Katrien; Nicolay, Klaas

    2015-01-01

    The use of MR imaging and spectroscopy for studying cardiovascular disease processes in small animals has increased tremendously over the past decade. This is the result of the remarkable advances in MR technologies and the increased availability of genetically modified mice. MR techniques provide a

  18. Advances in Small Animal Imaging Systems

    Science.gov (United States)

    Loudos, George K.

    2007-11-01

    The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided.

  19. Advances in Small Animal Imaging Systems

    International Nuclear Information System (INIS)

    Loudos, George K.

    2007-01-01

    The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided

  20. Blended learning in the small animal clinic

    DEFF Research Database (Denmark)

    Langebæk, Rikke

    2011-01-01

    -lab (one day) and Step 4: live animal surgery (four days). The implementation of the Surgical Skills Lab as an introduction to training on real animals (cadavers and research pigs) seems to be a valuable, practical, economical and safe educational tool that is highly appreciated by students. Since...... the implementation of these new teaching methods (e-learning and Skills Lab), teachers have ascertained a more satisfactory level of preparation, students that seem more focused and live-animal surgery that is conducted at a more ‘professional’ level than before. Finally, our research in this field shows......At the Department of Small Animal Clinical Sciences, Basic Surgical Skills are taught in groups of 30-35 students in the first year of the master program (4th year students). The eight day course is an example of ‘blended learning’ in which students use our e-learning-material (Step 1) to prepare...

  1. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  2. Attenuation correction for small animal PET tomographs

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Patrick L [David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095 (United States); Rannou, Fernando R [Departamento de Ingenieria Informatica, Universidad de Santiago de Chile (USACH), Av. Ecuador 3659, Santiago (Chile); Chatziioannou, Arion F [David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095 (United States)

    2005-04-21

    Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-sized and one rat-sized) and two animal subjects (one mouse and one rat) were scanned in CTI Concorde Microsystem's microPET (registered) Focus{sup TM} for emission and transmission data and in ImTek's MicroCAT{sup TM} II for transmission data. PET emission image values were calibrated against a scintillation well counter. Results indicate that the scale factor method of attenuation correction places the average measured activity concentration about the expected value, without correcting for the cupping artefact from attenuation. Noise analysis in the phantom studies with the PET-based method shows that noise in the transmission data increases the noise in the corrected emission data. The CT-based method was accurate and delivered low-noise images suitable for both PET data correction and PET tracer localization.

  3. Recent advances in small animal genetics.

    Science.gov (United States)

    Bannasch, Danika L; Hughes, Angela M

    2006-05-01

    The whole genome sequence of the dog is complete, and partial sequencing of the cat genome is underway. Sequences allow the molecular basis for inherited diseases to be more easily determined, leading to development of DNA tests to verify carrier and affected states as well as potential gene therapy for the treatment of those diseases. To help veterinarians provide genetic services to their clients, the molecular genetic tests currently available are listed in this article. In addition, cloning of small animals is now available to clients on a commercial basis. Information about the cloning process and possible health issues in clones are discussed.

  4. [New drugs for small animals in 2014].

    Science.gov (United States)

    Emmerich, I U

    2015-01-01

    In 2014, six active pharmaceutical ingredients were released on the German market for small animals. Those are the ektoparasiticide of the isoxazoline group afoxolaner (NexGard®) and fluralaner (Bravecto®) and the neonicotinoid dinotefuran (Vectra 3D, Vectra Felis), the antidiabetic protamine zinc insulin of human origin (ProZinc®), the antifungal agent ketoconazole (Fugazid®) as well as the cytostatic drug oclacitinib (Apoquel®). Two substances were authorized for an additional species. The antiparasiticide eprinomectin and the antibiotic clindamycin were also authorized for use in cats. In addition, two active pharmaceutical ingredients, which were approved 2014 for use in human medicine and are of potential interest to veterinary medicine, are discussed. These are the antihypertensive drug riociguat and the urological substance mirabegron.

  5. Small-Animal Models of Zika Virus.

    Science.gov (United States)

    Julander, Justin G; Siddharthan, Venkatraman

    2017-12-16

    Zika virus (ZIKV) infection can result in serious consequences, including severe congenital manifestations, persistent infection in the testes, and neurologic sequelae. After a pandemic emergence, the virus has spread to much of North and South America and has been introduced to many countries outside of ZIKV-endemic areas as infected travelers return to their home countries. Rodent models have been important in gaining a better understanding of the wide range of disease etiologies associated with ZIKV infection and for the initial phase of developing countermeasures to prevent or treat viral infections. We discuss herein the advantages and disadvantages of small-animal models that have been developed to replicate various aspects of disease associated with ZIKV infection. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  6. Blended learning in the small animal clinic

    DEFF Research Database (Denmark)

    Langebæk, Rikke

    2011-01-01

    At the Department of Small Animal Clinical Sciences, Basic Surgical Skills are taught in groups of 30-35 students in the first year of the master program (4th year students). The eight day course is an example of ‘blended learning’ in which students use our e-learning-material (Step 1) to prepare...... for the practical part of the course (Step 2, 3 and 4). From their home computers, students log on to the e-learning platform of Copenhagen University: https://absalon.ku.dk and go to the Basic Surgical Skills course, which consist of a line of chapters concerning a variety of surgical subjects. Each subject...... a widespread satisfaction with this flexible method, which permits them to observe – repeatedly - how to perform the actual clinical and surgical procedures prior to performing them in class. The practical part of the course consists of Step 2: the Surgical Skills Lab with Dummies (two days), Step 3: Cadaver...

  7. Enclosure for small animals during awake animal imaging

    Science.gov (United States)

    Goddard, Jr., James S

    2013-11-26

    An enclosure or burrow restrains an awake animal during an imaging procedure. A tubular body, made from a radiolucent material that does not attenuate x-rays or gamma rays, accepts an awake animal. A proximal end of the body includes an attachment surface that corresponds to an attachment surface of an optically transparent and optically uniform window. An anti-reflective coating may be applied to an inner surface, an outer surface, or both surfaces of the window. Since the window is a separate element of the enclosure and it is not integrally formed as part of the body, it can be made with optically uniform thickness properties for improved motion tracking of markers on the animal with a camera during the imaging procedure. The motion tracking information is then used to compensate for animal movement in the image.

  8. Animal leptospirosis in small tropical areas.

    Science.gov (United States)

    Desvars, A; Cardinale, E; Michault, A

    2011-02-01

    Leptospirosis is the most widespread zoonosis in the world. Humans become infected through contact with the urine of carrier animals, directly or via contaminated environments. This review reports available data on animal leptospirosis in ten tropical islands: Barbados, Martinique, Guadeloupe, Grenada, Trinidad, New Caledonia, Hawaii, French Polynesia, La Réunion and Mayotte. Leptospirosis is endemic in these insular wild and domestic fauna. Each island presents a specific panel of circulating serovars, closely linked with animal and environmental biodiversity, making it epidemiologically different from the mainland. Rats, mongooses and mice are proven major renal carriers of leptospires in these areas but dogs also constitute a significant potential reservoir. In some islands seroprevalence of leptospirosis in animals evolves with time, inducing changes in the epidemiology of the human disease. Consequently more investigations on animal leptospirosis in these ecosystems and use of molecular tools are essential for prevention and control of the human disease.

  9. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  10. Prevalence and pattern of small animal orthopaedic conditions at ...

    African Journals Online (AJOL)

    Small animal orthopaedic case records of a 20-year period were surveyed to obtain the prevalence and pattern of orthopaedic conditions presented to the Veterinary Teaching Hospital (VTH), University of Ibadan, Nigeria, with the objective of providing data for planning on small animal healthcare facilities, policy ...

  11. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. PAIN MANAGEMENT IN SMALL ANIMAL SURGERY

    Directory of Open Access Journals (Sweden)

    Selma Filipović

    2013-03-01

    Full Text Available The field of pain management has profoundly evolved over the last decade. The International Association for the Study of Pain (IASP defines pain as „an unpleasant sensory and emotional experience associated with actual or potential tissue damage or described in terms of such damage“. Adequate pain management should be a priority in veterinary surgery in terms of ethics, animal welfare, and reduce of morbidity and mortality. In veterinary medicine, scoring systems for pain rely on interpreting or measuring the consequences of pain. Results of numerous studies on pain support two treatment concepts, preventive and multimodal analgesia. Preventive analgesia includes analgesic application before occurrence of pain stimuli. Multimodal approach involves application of combination of two or more analgesics.Key words: pain, pain management, preventive analgesia, multimodal analgesia

  13. Cortical inactivation by cooling in small animals

    Directory of Open Access Journals (Sweden)

    Ben eCoomber

    2011-06-01

    Full Text Available Reversible inactivation of the cortex by surface cooling is a powerful method for studying the function of a particular area. Implanted cooling cryoloops have been used to study the role of individual cortical areas in auditory processing of awake-behaving cats. Cryoloops have also been used in rodents for reversible inactivation of the cortex, but recently there has been a concern that the cryoloop may also cool non-cortical structures either directly or via the perfusion of blood, cooled as it passed close to the cooling loop. In this study we have confirmed that the loop can inactivate most of the auditory cortex without causing a significant reduction in temperature of the auditory thalamus or other sub-cortical structures. We placed a cryoloop on the surface of the guinea pig cortex, cooled it to 2°C and measured thermal gradients across the neocortical surface. We found that the temperature dropped to 20-24°C among cells within a radius of about 2.5mm away from the loop. This temperature drop was sufficient to reduce activity of most cortical cells and led to the inactivation of almost the entire auditory region. When the temperature of thalamus, midbrain, and middle ear were measured directly during cortical cooling, there was a small drop in temperature (about 4°C but this was not sufficient to directly reduce neural activity. In an effort to visualise the extent of neural inactivation we measured the uptake of thallium ions following an intravenous injection. This confirmed that there was a large reduction of activity across much of the ipsilateral cortex and only a small reduction in subcortical structures.

  14. Veterinary Teaching Hospital to launch small animal outpatient imaging service

    OpenAIRE

    Jackson, Christy

    2009-01-01

    Beginning in June 2009, the Virginia-Maryland Regional College of Veterinary Medicine at Virginia Tech's Veterinary Teaching Hospital will introduce a new outpatient advanced imaging service for surrounding small animal veterinarian practices.

  15. Technical note - Considerations for MR imaging of small animals

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Martin A., E-mail: m.a.baker@liv.ac.u [Small Animal Teaching Hospital, University of Liverpool, Chester High Road, Neston, Wirral CH64 7TE (United Kingdom)

    2011-05-15

    Routine clinical veterinary use of MR scanning is becoming more common. This article addresses the major technical considerations for radiographers performing MR examinations on small animals and provides practical advice for scanning techniques.

  16. Small animal PET and its applications in biomedical research

    International Nuclear Information System (INIS)

    Qiu Feichan

    2004-01-01

    Positron emission tomography (PET) is a nuclear medical imaging technique that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. As the leading technology in nuclear medicine, PET has extended its applications from the clinical field to the study of small laboratory animals. In recent years, the development of new detector technology has dramatically improved the spatial resolution and image quality of small animal PET scanner, which is being used increasingly as a basic tool in modern biomedical research. In particular, small animal PET will play an important role in drug discovery and development, in the study of small animal models of human diseases, in characterizing gene expression and in many other ways. (authors)

  17. Pattern of Household Composition and Animal Ethics among Small ...

    African Journals Online (AJOL)

    A survey was carried out to assess the extent of animal welfare and ethics among the small ruminant farmers in Iwo Local Government. Iwo Local Government is well accredited for small ruminant production, their production practices were assessed through the use structured questionnaires. Results showed that majority of ...

  18. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  19. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...... is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small...

  20. Congenital and inherited renal disease of small animals.

    Science.gov (United States)

    Greco, D S

    2001-03-01

    Congenital renal diseases are present at birth and may be determined genetically; familial renal disorders occur in related animals with a higher frequency than would be expected by chance, and frequently are inherited. The most common familial disorders in cats and dogs include renal amyloidosis, renal dysplasia, polycystic kidneys, basement membrane disorders, and tubular dysfunction (Fanconi's syndrome). This article alerts the veterinarian to commonly observed congenital and hereditary conditions of the kidneys in small animals.

  1. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  2. Frequency domain fluorescence diffuse tomography of small animals

    Science.gov (United States)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  3. Treatment planning for a small animal using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.

    2007-01-01

    The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human

  4. On the surveillance for animal diseases in small herds

    DEFF Research Database (Denmark)

    Greiner, Matthias; Dekker, Aldo

    2005-01-01

    Small herds may present a problem in surveillance for infectious animal diseases because typical levels of a within-herd design prevalence are not directly applicable. We suggest a definition of small herds as those smaller than 2/(within-herd design prevalence) on the basis that such herds would...... be expected to have less than two (i.e. only one) infected animals. Consequently, the probability of detecting small herds cannot be improved by choosing a larger sample size within the herd. We derive necessary sample sizes of herds and the probability ("confidence") of detecting disease within a stratum...... of small herds, given the among-herd design prevalence and test diagnostic sensitivity. Both a binomial model and a Poisson model can be used to establish the confidence for a given sample size of herds (and vice versa). The results of a simulation study suggest that the Poisson model provides more...

  5. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  6. Articulated Planar Reformation for Change Visualization in Small Animal Imaging

    NARCIS (Netherlands)

    Kok, P.; Baiker, M.; Hendriks, E.A.; Post, F.H.; Dijkstra, J.; Löwik, C.W.G.M.; Lelieveldt, B.P.F.; Botha, C.P.

    2010-01-01

    The analysis of multi-timepoint whole-body small animal CT data is greatly complicated by the varying posture of the subject at different timepoints. Due to these variations, correctly relating and comparing corresponding regions of interest is challenging. In addition, occlusion may prevent

  7. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  8. Marketing small animal theriogenology services--one perspective.

    Science.gov (United States)

    Barber, J A

    2007-08-01

    Once a decision is made to add small animal theriogenology services to a practice, marketing strategies must be developed and implemented to attract clients to the new services. Marketing strategies for the niche market of theriogenology include start-up marketing methods, referral programs, internal marketing, and continued marketing. Marketing theriogenology services is a dynamic, ongoing process that never ends.

  9. A Small Scale Experimental Study: Using Animations to Learn Vocabulary

    Science.gov (United States)

    Kayaoglu, M. Naci; Dag Akbas, Raside; Ozturk, Zeynep

    2011-01-01

    This study attempts to investigate whether a difference exists between learning vocabulary via animation and via traditional paper-based method. This small scale study was conducted at Karadeniz Technical University in academic year 2009-2010. Two pre-intermediate classes were randomly selected as the experimental group (n = 17), and control group…

  10. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  11. Dissemination of parasites by animal movements in small ruminant farms.

    Science.gov (United States)

    Vasileiou, N G C; Fthenakis, G C; Papadopoulos, E

    2015-09-30

    The present paper discusses the spread of parasites by animal movements in small ruminant farms; it focuses in dissemination of parasitic forms that would lead to subsequent infection of sheep or goats. Systems of small ruminant production involve a component of animal movement (e.g., grazing) as part of routine husbandry, which favors spread of parasitic forms; that refers mainly to parasites of the digestive system (nematodes, trematodes, cestodes, protozoa), as well as helminthes of the respiratory system, although dissemination of the various parasitic forms in the environment would not always result to subsequent infection; external parasites may also be disseminated during movements, e.g., to inhabit wooden poles used in fencing. New livestock into a farm constitutes a biosecurity hazard and the most common means to introducing new parasitic pathogens into a farm; in contemporary small ruminant health management, this contributes in dissemination of anthelmintic resistant parasitic strains; other parasitic disease agents (e.g., mange mites, ticks) may also be spread into a farm that way. Often, especially in small scale farming, visits of rams or bucks take place from one farm to another during the mating season; in such cases, ectoparasites (e.g., mange mites) can be disseminated through direct contact of animals, as well other pathogens (e.g., Toxoplasma gondii, Neospora caninum) via the semen. During transportation of sheep/goats, parasitic forms can also spread, as well as during movement of sheep or goats to slaughterhouses, in which case dogs present in these places would contribute to their dissemination. Spread of life forms of various parasites can also occur from animal species present in the environment of sheep or goats; these include animals present within a farm, stray dogs roaming around a farm (e.g., for spread of Multiceps multiceps, Echinococcus granulosus, Taenia hydatigena, N. caninum), cats commanding the environment of a farm (e.g., for

  12. II International Congress on small animals and JDC-VEPA I National Meeting of Research in Animal Science

    OpenAIRE

    Autores Varios

    2013-01-01

    SCIENTIFIC RESEARCH INSTITUTE - INICIENFACULTY OF AGRICULTURAL SCIENCES II International Congress on small animals and JDC-VEPA I National Meeting of Animal science research RESEARCH GROUPS INPANTA-CEAS-GREBIAL-IRABI II International Congress on small animals and JDC-VEPA I National Meeting of Research in Animal Science

  13. Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

    International Nuclear Information System (INIS)

    Donnelley, Martin; Parsons, David; Morgan, Kaye; Siu, Karen

    2010-01-01

    Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 μm and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the

  14. Simulation of time curves in small animal PET using GATE

    International Nuclear Information System (INIS)

    Simon, Luc; Strul, Daniel; Santin, Giovanni; Krieguer, Magalie; Morel, Christian

    2004-01-01

    The ClearPET project of the Crystal Clear Collaboration (CCC) is building spin-off technology for high resolution small animal Positron Emission Tomography (PET). Monte Carlo simulation is essential for optimizing the specifications of these systems with regards to their most important characteristics, such as spatial resolution, sensitivity, or count rate performance. GATE, the Geant4 Application for Tomographic Emission simulates the passing of time during real acquisitions, allowing to handle dynamic systems such as decaying source distributions or moving detectors. GATE output is analyzed on an event-by-event basis. The time associated with each single event allows to sort coincidences and to model dead-time. This leads to the study of time curves for a prospective small animal PET scanner design. The count rates of true, and random coincidences are discussed together with the corresponding Noise Equivalent Count (NEC) rates as a function of some PET scanner specifications such as detector dead time, or coincidence time window

  15. Current concepts for experimental micro-CT in small animals

    International Nuclear Information System (INIS)

    Bag, S.; Schambach, S.J.; Boll, H.; Groden, C.; Brockmann, M.A.; Schilling, L.

    2010-01-01

    The number of publications describing the use of micro-computed tomography (μCT) for preclinical in vivo imaging of small animals has risen considerably within the last few years. The purpose of this review is to familiarize the reader with the basic principles of μCT, to present successful experimental approaches in order of the evaluated organ system, and to highlight limitations that need to be considered when planning μCT-based studies. (orig.)

  16. Small Animal Massage Therapy: A Brief Review and Relevant Observations.

    Science.gov (United States)

    Formenton, Maira Rezende; Pereira, Marco Aurélio Amador; Fantoni, Denise Tabacchi

    2017-12-01

    Massage therapy is becoming increasingly popular in human and animal physiotherapy and rehabilitation. Wider application of the technique led to research efforts aimed at providing scientific support to anecdotal beneficial effects, particularly pain relief. Recent studies have shown that massage therapy alters dopamine and serotonin levels, decreases noradrenaline levels, and modulates the immune system. Psychological effects such as reduction of stress and anxiety, with improvement of depressive patients, have been reported in humans. This article set out to review the major aspects of massage therapy based on recent publications on the topic, and to extrapolate concepts and practical aspects described in human physiotherapy to the veterinary patient, particularly the applicability of different techniques in Small Animal Medicine. Indications of massage therapy in small animals include pain relief, orthopedic rehabilitation, Canine Sports Medicine, intensive care, and management of nonspecific edema. Techniques described in this article were originally intended for use in humans and scientific data supporting anecdotal, beneficial effects in domestic animals are still lacking; this fruitful area for research is therefore open to veterinary professionals. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. In vivo small animal imaging: Current status and future prospects

    International Nuclear Information System (INIS)

    Kagadis, George C.; Loudos, George; Katsanos, Konstantinos; Langer, Steve G.; Nikiforidis, George C.

    2010-01-01

    The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

  18. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  19. Bone scintigraphy for the investigation of lameness in small animals

    International Nuclear Information System (INIS)

    Bolln, G.; Franke, C.

    2010-01-01

    Bone scintigraphy has been used as a helpful method in diagnosing lameness in small animals. It is a sensitive, non-invasive method to evaluate bone lesions and orthopaedic disorders. It provides a functional image of the skeleton and thereby aiding in the localisation and diagnosing of obscure lameness. Compared to human medicine one important difference is the inability of an animal to characterize its pain to the examiner. Another difference is the lacking cooperation of an animal during bone scintigraphy. Before this background are shown on the basis of 5 examples the advantages, the method and the different indication of bone scintigraphy. The technique of this method arrives from a human medicine protocol of a 2-phase-bone-scintigraphy and has to be done under light anaesthesia, to avoid artefacts of movement during acquisitions. The authors are convinced that bone scintigraphy is a very useful and diagnostic method for evaluation of obscure lameness because it can give a quick diagnosis and aimed therapy. Therefore secondary changes and additional costs can be avoided for the animal and its owner. (orig.)

  20. Computer-aided pulmonary image analysis in small animal models

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J. [Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Bagci, Ulas, E-mail: ulasbagci@gmail.com [Center for Research in Computer Vision (CRCV), University of Central Florida (UCF), Orlando, Florida 32816 (United States); Kramer-Marek, Gabriela [The Institute of Cancer Research, London SW7 3RP (United Kingdom); Luna, Brian [Microfluidic Laboratory Automation, University of California-Irvine, Irvine, California 92697-2715 (United States); Kubler, Andre [Department of Medicine, Imperial College London, London SW7 2AZ (United Kingdom); Dey, Bappaditya; Jain, Sanjay [Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Foster, Brent [Department of Biomedical Engineering, University of California-Davis, Davis, California 95817 (United States); Papadakis, Georgios Z. [Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Camp, Jeremy V. [Department of Microbiology and Immunology, University of Louisville, Louisville, Kentucky 40202 (United States); Jonsson, Colleen B. [National Institute for Mathematical and Biological Synthesis, University of Tennessee, Knoxville, Tennessee 37996 (United States); Bishai, William R. [Howard Hughes Medical Institute, Chevy Chase, Maryland 20815 and Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Udupa, Jayaram K. [Medical Image Processing Group, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2015-07-15

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

  1. Veterinarians' perceptions of behaviour support in small-animal practice.

    Science.gov (United States)

    Roshier, A L; McBride, E A

    2013-03-09

    Veterinarians are professionals considered to be at the forefront of animal welfare, including behaviour medicine. However, concerns raised, both within the profession and without, highlight that the support offered is not optimal, due to deficiencies in veterinary training, which focuses on physical aspects and overlooks psychological aspects. This preliminary study explored the experiences and perceptions of six veterinarians (three male, three female, age range: 23-55 years) in two UK small-animal practices. Seventeen annual booster consultations were videoed and conversations thematically analysed for welfare topics discussed. Both veterinarians and clients completed questionnaires to gather demographic information and perspectives. All veterinarians recognised behaviour as a component of their caseload, and acknowledged that clients expected them to provide behaviour support. Veterinarians varied in their experiences of and confidence in providing behaviour support. Five felt unable to meet client expectations; four did not feel their training had prepared them sufficiently. Only one provided dedicated behaviour consultations, the others referred cases. All provided suggestions for behaviour skills needed for new veterinary graduates. The study has afforded an insight into the experiences of a small opportunistic sample of veterinarians. The data indicated important limitations regarding time available in general consultations to discuss behaviour concerns, and practitioner knowledge and skill in detection, anamnesis, assessment and provision of appropriate behaviour information. Suggestions for veterinary training in behaviour are provided.

  2. Veterinarians' perceptions of behaviour support in small-animal practice

    Science.gov (United States)

    Roshier, A. L.; McBride, E. A.

    2013-01-01

    Veterinarians are professionals considered to be at the forefront of animal welfare, including behaviour medicine. However, concerns raised, both within the profession and without, highlight that the support offered is not optimal, due to deficiencies in veterinary training, which focuses on physical aspects and overlooks psychological aspects. This preliminary study explored the experiences and perceptions of six veterinarians (three male, three female, age range: 23–55 years) in two UK small-animal practices. Seventeen annual booster consultations were videoed and conversations thematically analysed for welfare topics discussed. Both veterinarians and clients completed questionnaires to gather demographic information and perspectives. All veterinarians recognised behaviour as a component of their caseload, and acknowledged that clients expected them to provide behaviour support. Veterinarians varied in their experiences of and confidence in providing behaviour support. Five felt unable to meet client expectations; four did not feel their training had prepared them sufficiently. Only one provided dedicated behaviour consultations, the others referred cases. All provided suggestions for behaviour skills needed for new veterinary graduates. The study has afforded an insight into the experiences of a small opportunistic sample of veterinarians. The data indicated important limitations regarding time available in general consultations to discuss behaviour concerns, and practitioner knowledge and skill in detection, anamnesis, assessment and provision of appropriate behaviour information. Suggestions for veterinary training in behaviour are provided. PMID:23475046

  3. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  4. Integration of optical imaging with a small animal irradiator

    Energy Technology Data Exchange (ETDEWEB)

    Weersink, Robert A., E-mail: robert.weersink@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Ansell, Steve; Wang, An; Wilson, Graham [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Shah, Duoaud [Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Lindsay, Patricia E. [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 1A1 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 1A1 (Canada); Ontario Cancer Institute, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5S 1A1 (Canada)

    2014-10-15

    Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two

  5. Prompt gamma-ray imaging for small animals

    Science.gov (United States)

    Xu, Libai

    Small animal imaging is recognized as a powerful discovery tool for small animal modeling of human diseases, which is providing an important clue to complete understanding of disease mechanisms and is helping researchers develop and test new treatments. The current small animal imaging techniques include positron emission tomography (PET), single photon emission tomography (SPECT), computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound (US). A new imaging modality called prompt gamma-ray imaging (PGI) has been identified and investigated primarily by Monte Carlo simulation. Currently it is suggested for use on small animals. This new technique could greatly enhance and extend the present capabilities of PET and SPECT imaging from ingested radioisotopes to the imaging of selected non-radioactive elements, such as Gd, Cd, Hg, and B, and has the great potential to be used in Neutron Cancer Therapy to monitor neutron distribution and neutron-capture agent distribution. This approach consists of irradiating small animals in the thermal neutron beam of a nuclear reactor to produce prompt gamma rays from the elements in the sample by the radiative capture (n, gamma) reaction. These prompt gamma rays are emitted in energies that are characteristic of each element and they are also produced in characteristic coincident chains. After measuring these prompt gamma rays by surrounding spectrometry array, the distribution of each element of interest in the sample is reconstructed from the mapping of each detected signature gamma ray by either electronic collimations or mechanical collimations. In addition, the transmitted neutrons from the beam can be simultaneously used for very sensitive anatomical imaging, which provides the registration for the elemental distributions obtained from PGI. The primary approach is to use Monte Carlo simulation methods either with the specific purpose code CEARCPG, developed at NC State University or with the general purpose

  6. Use and preservation methods of bone grafts in small animals

    Directory of Open Access Journals (Sweden)

    Rafael Garabet Agopian

    2016-09-01

    Full Text Available The present review describes the main characteristics of bone grafts used in small animals. Bone grafts are tissues without vasculature, which facilitate the production of new bone cells with osteogenic and osteoinductive factors that lead to the differentiation of cells and structural support for bone marrow. The transplant of a graft is followed by three stages: osteogenesis, or the formation of new bone; osteoinduction, which is the differentiation of cells; and osteoconduction, the process of growth of mesenchymal cells and capillaries that results in new bone formation. The composition of bone grafts may include spongy bone, cortical bone, cortical-spongy bone, cartilage or bone marrow. Grafts can also be classified according to their origin, being autogenous tissue when they are transplanted from the same individual, allogenous (homologous when originating from another individual of the same species, and xenogenous when obtained from a different species.

  7. The therapeutic lamp: treating small-animal phobias.

    Science.gov (United States)

    Wrzesien, Maja; Alcañiz, Mariano; Botella, Cristina; Burkhardt, Jean-Marie; Bretón-López, Juana; Ortega, Mario; Brotons, Daniel Beneito

    2013-01-01

    We all have an irrational fear or two. Some of us get scared by an unexpected visit from a spider in our house; others get nervous when they look down from a high building. Fear is an evolutionary and adaptive function that can promote self-preservation and help us deal with the feared object or situation. However, when this state becomes excessive, it might develop into psychological disorders such as phobias, producing high anxiety and affecting everyday life. The Therapeutic Lamp is an interactive projection-based augmented-reality system for treating small-animal phobias. It aims to increase patient-therapist communication, promote more natural interaction, and improve the patient's engagement in the therapy.

  8. Utility of Small Animal Models of Developmental Programming.

    Science.gov (United States)

    Reynolds, Clare M; Vickers, Mark H

    2018-01-01

    Any effective strategy to tackle the global obesity and rising noncommunicable disease epidemic requires an in-depth understanding of the mechanisms that underlie these conditions that manifest as a consequence of complex gene-environment interactions. In this context, it is now well established that alterations in the early life environment, including suboptimal nutrition, can result in an increased risk for a range of metabolic, cardiovascular, and behavioral disorders in later life, a process preferentially termed developmental programming. To date, most of the mechanistic knowledge around the processes underpinning development programming has been derived from preclinical research performed mostly, but not exclusively, in laboratory mouse and rat strains. This review will cover the utility of small animal models in developmental programming, the limitations of such models, and potential future directions that are required to fully maximize information derived from preclinical models in order to effectively translate to clinical use.

  9. Imaging of hypoxia in small animals with 18F fluoromisonidasole

    Directory of Open Access Journals (Sweden)

    Kilian Krzysztof

    2016-06-01

    Full Text Available A method of automated synthesis of [18F]fluoromisonidazole ([18F]FMISO for application in preclinical studies on small animals was presented. A remote-controlled synthesizer Synthra RNplus was used for nucleophilic substitution of NITTP (1′-(2′-nitro-1-imidazolyl-2-O-tetrahydropyranyl-3-O-toluenesulfonyl-propanediol with 18F anion. Labeling of 5 mg of precursor was performed in anhydrous acetonitrile at 100°C for 10 min, and the hydrolysis with HCl was performed at 100°C for 5 min. Final purification was done with high-performance liquid chromatography (HPLC and the radiochemical purity of radiotracer was higher than 99%. Proposed [18F]FMISO synthesis was used as a reliable tool in studies on hypoxia in Lewis lung carcinoma (LLC in mouse models.

  10. Magnetic resonance imaging for precise radiotherapy of small laboratory animals

    Energy Technology Data Exchange (ETDEWEB)

    Frenzel, Thorsten [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie; Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kaul, Michael Gerhard; Ernst, Thomas Michael; Salamon, Johannes [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Jaeckel, Maria [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie; Schumacher, Udo [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kruell, Andreas [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie

    2017-05-01

    Radiotherapy of small laboratory animals (SLA) is often not as precisely applied as in humans. Here we describe the use of a dedicated SLA magnetic resonance imaging (MRI) scanner for precise tumor volumetry, radiotherapy treatment planning, and diagnostic imaging in order to make the experiments more accurate. Different human cancer cells were injected at the lower trunk of pfp/rag2 and SCID mice to allow for local tumor growth. Data from cross sectional MRI scans were transferred to a clinical treatment planning system (TPS) for humans. Manual palpation of the tumor size was compared with calculated tumor size of the TPS and with tumor weight at necropsy. As a feasibility study MRI based treatment plans were calculated for a clinical 6 MV linear accelerator using a micro multileaf collimator (μMLC). In addition, diagnostic MRI scans were used to investigate animals which did clinical poorly during the study. MRI is superior in precise tumor volume definition whereas manual palpation underestimates their size. Cross sectional MRI allow for treatment planning so that conformal irradiation of mice with a clinical linear accelerator using a μMLC is in principle feasible. Several internal pathologies were detected during the experiment using the dedicated scanner. MRI is a key technology for precise radiotherapy of SLA. The scanning protocols provided are suited for tumor volumetry, treatment planning, and diagnostic imaging.

  11. [A respiratory microvalve for spontaneously breathing anesthetized small animals].

    Science.gov (United States)

    Barnikol, W K; Hiller, B; Guth, S

    1994-03-01

    For the accurate functional analysis of the gas exchange in the lungs or evaluation of artificial oxygen carriers in spontaneously breathing anaesthetized small animals, we developed a new respiratory micro-valve. The body of the valve is made of aluminium, and the flaps are made of silicone rubber. The maximum flow rate in a rat measured with a pneumotachograph and the micro-valve was an average of 19.9 ml/s during inspiration, and 17.8 ml/s during expiration. The pressure measured in the tracheal tube was -0.85 during inspiration, and +0.39 cm H2O during expiration; the end-expiratory pressure in the tube was zero. In two experiments with anaesthetised rats lasting 4-5 hours, ventilation, oxygen uptake, carbon dioxide release and the respiratory exchange ratio were 638 ml/min/kg, 21.7 ml O2(STPD)/min/kg, 16.6 ml CO2(STPD)/min/kg, and 0.77, respectively. There was no significant change in any parameter during the experiment. The micro-valve increases the dead space by approximately 35%, but this is well tolerated by the rats, which compensate by increasing their tidal volume by about 10 to 15%. The major advantage of using the micro-valve in comparison with other methods is the fact that the true difference between inspiratory and mean mixed expiratory gas can be measured with great accuracy. The micro-valve can readily be adjusted for optimal use with a range of animals.

  12. Imaging modalities used to confirm diaphragmatic hernia in small animals

    International Nuclear Information System (INIS)

    Williams, J.; Leveille, R.; Myer, C.W.

    1998-01-01

    When a patient is presented for treatment following a traumatic accident such as being hit by a car, thoracic radiographs are usually an integral part of the overall diagnostic evaluation. Diagnosis at diaphragmatic hernia (DH) is often challenging in small animals. The thorax may contain substantial fluid, thereby masking the presence of cranially displaced abdominal soft tissues (e.g., liver or spleen). The most common cause of decreased radiographic visualization of the diaphragm on survey radiographs is pleural fluid; however, the second most common cause is DH. Obviously, if a gas-filledviscus is identified within the thoracic cavity on survey radiographs, the diagnosis of DH is straightforward and relatively routine. If, however, there is substantial pleural effusion and the herniated structure is a soft tissue parenchymal organ (e.g., liver or spleen), the diagnosis is less clearly defined on survey radiographs. This review discusses the various imaging modalities (survey, positional, and contrast-enhanced radiographs and ultrasonography) that can be used in the diagnosis or confirmation of DH

  13. Use and preservation methods of bone grafts in small animals

    Directory of Open Access Journals (Sweden)

    Rafael Garabet Agopian

    2016-09-01

    Full Text Available http://dx.doi.org/10.5007/2175-7925.2016v29n3p11 The present review describes the main characteristics of bone grafts used in small animals. Bone grafts are tissues without vasculature, which facilitate the production of new bone cells with osteogenic and osteoinductive factors that lead to the differentiation of cells and structural support for bone marrow. The transplant of a graft is followed by three stages: osteogenesis, or the formation of new bone; osteoinduction, which is the differentiation of cells; and osteoconduction, the process of growth of mesenchymal cells and capillaries that results in new bone formation. The composition of bone grafts may include spongy bone, cortical bone, cortical-spongy bone, cartilage or bone marrow. Grafts can also be classified according to their origin, being autogenous tissue when they are transplanted from the same individual, allogenous (homologous when originating from another individual of the same species, and xenogenous when obtained from a different species.

  14. Filtering and deconvolution for bioluminescence imaging of small animals

    International Nuclear Information System (INIS)

    Akkoul, S.

    2010-01-01

    This thesis is devoted to analysis of bioluminescence images applied to the small animal. This kind of imaging modality is used in cancerology studies. Nevertheless, some problems are related to the diffusion and the absorption of the tissues of the light of internal bioluminescent sources. In addition, system noise and the cosmic rays noise are present. This influences the quality of the images and makes it difficult to analyze. The purpose of this thesis is to overcome these disturbing effects. We first have proposed an image formation model for the bioluminescence images. The processing chain is constituted by a filtering stage followed by a deconvolution stage. We have proposed a new median filter to suppress the random value impulsive noise which corrupts the acquired images; this filter represents the first block of the proposed chain. For the deconvolution stage, we have performed a comparative study of various deconvolution algorithms. It allowed us to choose a blind deconvolution algorithm initialized with the estimated point spread function of the acquisition system. At first, we have validated our global approach by comparing our obtained results with the ground truth. Through various clinical tests, we have shown that the processing chain allows a significant improvement of the spatial resolution and a better distinction of very close tumor sources, what represents considerable contribution for the users of bioluminescence images. (author)

  15. Design considerations and construction of a small animal PET prototype

    International Nuclear Information System (INIS)

    Tzanakos, G.; Nikolaou, M.; Drakoulakos, D.; Karamitros, D.; Kontaxakis, G.; Logaras, E.; Panayiotakis, G.; Pavlopoulos, S.; Skiadas, M.; Spyrou, G.; Thireou, T.; Vamvakas, D.

    2006-01-01

    We are developing a small animal PET scanner consisting of two block detectors, each made of 216 BGO crystals of dimensions 3.75 mmx3.75 mmx20 mm, cylindrically arranged and coupled to a position-sensitive photomultiplier tube (R2486 PSPMT). Our design was based on a very detailed Monte Carlo, that simulates the function of a PET scanner from the system level down to the individual γ-ray detectors. We have made laboratory measurements of the individual detector performance as well as measurements of characteristics of the PSPMTs. The two detector blocks which will form the basic tomographic unit have been assembled. We are developing electronics to individually process (amplify and digitize) anode signals, and use field programmable gate arrays (FPGAs) in the position determination and energy measurement of the γ-rays. At present, as an intermediate step, we are using the electronics supplied from Hamamatsu to study various aspects of the system and produce initial images

  16. Resolution, sensitivity and precision with autoradiography and small animal positron emission tomography: implications for functional brain imaging in animal research

    International Nuclear Information System (INIS)

    Schmidt, Kathleen C.; Smith, Carolyn Beebe

    2005-01-01

    Quantitative autoradiographic methods for in vivo measurement of regional rates of cerebral blood flow, glucose metabolism, and protein synthesis contribute significantly to our understanding of physiological and biochemical responses of the brain to changes in the environment. A disadvantage of these autoradiographic methods is that experimental animals can be studied only once. With the advent of small animal positron emission tomography (PET) and with increases in the sensitivity and spatial resolution of scanners it is now possible to use adaptations of these methods in experimental animals with PET. These developments allow repeated studies of the same animal, including studies of the same animal under different conditions, and longitudinal studies. In this review we summarize the tradeoffs between the use of autoradiography and small animal PET for functional brain imaging studies in animal research

  17. Monte Carlo simulation of small field electron beams for small animal irradiation

    International Nuclear Information System (INIS)

    Lee, Chung-Chi; Chen, Ai-Mei; Tung, Chuan-Jong; Chao, Tsi-Chian

    2011-01-01

    The volume effect of detectors in the dosimetry of small fields for photon beams has been well studied due to interests in radiosurgery and small beamlets used in IMRT treatments; but there is still an unexplored research field for small electron beams used in small animal irradiation. This study proposes to use the BEAM Monte Carlo (MC) simulation to assess characteristics of small electron beams (4, 6, 14, 30 mm in diameter) with the kinetic energies of 6 and 18 MeV. Three factors influencing beam characteristics were studied (1) AE and ECUT settings, (2) photon jaw settings and (3) simulation pixel sizes. Study results reveal that AE/ECUT settings at 0.7 MeV are adequate for linear accelerator treatment head simulation, while 0.521 MeV is more favorable to be used for the phantom study. It is also demonstrated that voxel size setting at 1/4 of the simulation field width in all directions is sufficient to achieve accurate results. As for the photon jaw setting, it has great impact on the absolute output of different field size setting (i.e. output factor) but with minimum effect on the relative lateral distribution.

  18. Performance evaluation of the Philips MOSAIC small animal PET scanner

    International Nuclear Information System (INIS)

    Huisman, Marc C.; Reder, Sybille; Ziegler, Sibylle I.; Schwaiger, Markus; Weber, Axel W.

    2007-01-01

    In this study an evaluation of the performance of the Philips MOSAIC small animal PET scanner is presented, with special emphasis on the ability of the system to provide quantitatively accurate PET images. The performance evaluation was structured according to NEMA-like procedures. The transaxial spatial resolution of the system (radial component) ranged between 2.7 mm FWHM at the centre and 3.2 mm FWHM at a radial offset of 45 mm from the centre. The axial spatial resolution of the system ranged between 3.4 mm FWHM at the centre and 5.8 mm FWHM at a radial offset of 45 mm from the centre. The scatter fraction was determined for a mouse- as well as for a rat-sized phantom, and the values obtained were 9.6% and 16.8%, respectively. For the mouse phantom, the maximum count rate measured was 560 kcps at 93 MBq; the maximum NEC rate equalled 308 kcps at 1.7 MBq/ml. For the rat phantom, these values were 400 kcps at 100 MBq and 129 kcps at 0.24 MBq/ml, respectively. The sensitivity of the system was derived to be 0.65%. An energy window between 410 and 665 keV was used in all experiments. The MOSAIC system exhibits moderate spatial resolution and sensitivity values, but good NEC performance. In combination with its relatively large field of view, the system allows for high-throughput whole-body imaging of mice and rats. The accurate measurement of relative changes in radiotracer distributions is feasible. (orig.)

  19. Acute spinal cord injury: tetraplegia and paraplegia in small animals.

    Science.gov (United States)

    Granger, Nicolas; Carwardine, Darren

    2014-11-01

    Spinal cord injury (SCI) is a common problem in animals for which definitive treatment is lacking, and information gained from its study has benefit for both companion animals and humans in developing new therapeutic approaches. This review provides an overview of the main concepts that are useful for clinicians in assessing companion animals with severe acute SCI. Current available advanced ancillary tests and those in development are reviewed. In addition, the current standard of care for companion animals following SCI and recent advances in the development of new therapies are presented, and new predictors of recovery discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. MR-based keyhole SPECT for small animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keum Sil; Roeck, Werner W; Nalcioglu, Orhan [Tu and Yuen Center for Functional Onco-Imaging, University of California, Irvine, Irvine, CA (United States); Gullberg, Grant T, E-mail: keumsill@uci.edu [Department of Radiotracer Development and Imaging Technology, Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2011-02-07

    The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system that can be used to obtain simultaneous MRI and SPECT images for small animal imaging. The reason for using a combined MR/SPECT system in this work is to eliminate any possible misregistration between the two sets of images when MR images are used as a priori information for SPECT. In nuclear imaging the target area is usually smaller than the entire object; thus, focusing the detector on the LFOV results in various advantages including the use of a smaller nuclear detector (less cost), smaller reconstruction region (faster reconstruction) and higher spatial resolution when used in conjunction with pinhole collimators with magnification. The MR/SPECT system can be used to choose a region of interest (ROI) for SPECT. A priori information obtained by the full field-of-view (FOV) MRI combined with the preliminary SPECT image can be used to reduce the dimensions of the SPECT reconstruction by limiting the computation to the smaller FOV while reducing artifacts resulting from the truncated data. Since the technique is based on SPECT imaging within the LFOV it will be called the keyhole SPECT (K-SPECT) method. At first MRI images of the entire object using a larger FOV are obtained to determine the location of the ROI covering the target organ. Once the ROI is determined, the animal is moved inside the radiofrequency (rf) coil to bring the target area inside the LFOV and then simultaneous MRI and SPECT are performed. The spatial resolution of the SPECT image is improved by employing a pinhole collimator with magnification >1 by having carefully calculated acceptance angles for each pinhole to avoid multiplexing. In our design all the pinholes are focused to

  1. Animals

    International Nuclear Information System (INIS)

    Skuterud, L.; Strand, P.; Howard, B.J.

    1997-01-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG)

  2. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  3. New approach to intracardiac hemodynamic measurements in small animals

    DEFF Research Database (Denmark)

    Eskesen, Kristian; Olsen, Niels T; Dimaano, Veronica L

    2012-01-01

    Invasive measurements of intracardiac hemodynamics in animal models have allowed important advances in the understanding of cardiac disease. Currently they are performed either through a carotid arteriotomy or via a thoracotomy and apical insertion. Both of these techniques have disadvantages...... and are not conducive to repeated measurements. Therefore, the purpose of this study was to develop a new technique for measuring intracardiac hemodynamics....

  4. Occupational health and safety in small animal veterinary practice: Part I — Nonparasitic zoonotic diseases

    OpenAIRE

    Weese, J. S.; Peregrine, A. S.; Armstrong, J.

    2002-01-01

    Zoonotic diseases are an ever-present concern in small animal veterinary practice and are often overlooked. A variety of nonparasitic zoonotic diseases may be encountered in small animal practice, including cat scratch disease (bartonellosis), cat bite abscesses, rabies, leptospirosis, methicillin-resistant Staphylococcus aureus, Clostridium difficile-associated diarrhea, salmonellosis, avian chlamydiosis, campylobacteriosis, dermatophytosis, and blastomycosis. These may cause human disease r...

  5. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  6. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  7. Theoretical considerations on maximum running speeds for large and small animals.

    Science.gov (United States)

    Fuentes, Mauricio A

    2016-02-07

    Mechanical equations for fast running speeds are presented and analyzed. One of the equations and its associated model predict that animals tend to experience larger mechanical stresses in their limbs (muscles, tendons and bones) as a result of larger stride lengths, suggesting a structural restriction entailing the existence of an absolute maximum possible stride length. The consequence for big animals is that an increasingly larger body mass implies decreasing maximal speeds, given that the stride frequency generally decreases for increasingly larger animals. Another restriction, acting on small animals, is discussed only in preliminary terms, but it seems safe to assume from previous studies that for a given range of body masses of small animals, those which are bigger are faster. The difference between speed scaling trends for large and small animals implies the existence of a range of intermediate body masses corresponding to the fastest animals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Small molecule alteration of RNA sequence in cells and animals.

    Science.gov (United States)

    Guan, Lirui; Luo, Yiling; Ja, William W; Disney, Matthew D

    2017-10-18

    RNA regulation and maintenance are critical for proper cell function. Small molecules that specifically alter RNA sequence would be exceptionally useful as probes of RNA structure and function or as potential therapeutics. Here, we demonstrate a photochemical approach for altering the trinucleotide expanded repeat causative of myotonic muscular dystrophy type 1 (DM1), r(CUG) exp . The small molecule, 2H-4-Ru, binds to r(CUG) exp and converts guanosine residues to 8-oxo-7,8-dihydroguanosine upon photochemical irradiation. We demonstrate targeted modification upon irradiation in cell culture and in Drosophila larvae provided a diet containing 2H-4-Ru. Our results highlight a general chemical biology approach for altering RNA sequence in vivo by using small molecules and photochemistry. Furthermore, these studies show that addition of 8-oxo-G lesions into RNA 3' untranslated regions does not affect its steady state levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Animals

    Energy Technology Data Exchange (ETDEWEB)

    Skuterud, L.; Strand, P. [Norwegian Radiation Protection Authority (Norway); Howard, B.J. [Inst. of Terrestrial Ecology (United Kingdom)

    1997-10-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG). 68 refs.

  10. Pet food recalls and pet food contaminants in small animals.

    Science.gov (United States)

    Bischoff, Karyn; Rumbeiha, Wilson K

    2012-03-01

    Most pet foods are safe, but incidents of chemical contamination occur and lead to illness and recalls. There were 11 major pet food recalls in the United States between 1996 and 2010 that were due to chemical contaminants or misformulations: 3 aflatoxin, 3 excess vitamin D3, 1 excess methionine, 3 inadequate thiamine, and 1 adulteration with melamine and related compounds and an additional 2 warnings concerning a Fanconilike renal syndrome in dogs after ingesting large amounts of chicken jerky treat products. This article describes clinical findings and treatment of animals exposed to the most common pet food contaminants.

  11. An Ethanol Vapor Chamber System for Small Animals

    Science.gov (United States)

    Wang, Jie; Jiang, Lihong; Du, Hongying; Mason, Graeme F.

    2012-01-01

    Ethanol vapor chambers have been utilized widely in alcohol research since their introduction in 1971, and implementations of these systems are now available commercially. Here, we present a modification of the chamber that can be built at lower cost and greater simplicity of operation. The six-chamber system for rats has multiple air pumps. Ethanol vapor levels are adjusted with the air flow rate, ethanol drip rate, and dilution with room air, without a heater or fans. Ethanol vapor concentrations are measured with a breathalyzer, using room air to dilute the vapor chamber output into the range of the breathalyzer. Multiple pumps provide backup to ensure animal survival in the case of failure of the primary air pump. Tests in animals demonstrated comfortable and stable elevation of blood ethanol, with tight control of the ethanol vapor concentrations and the ability to select from a broad range of levels. The ethanol vapor measurement was rapid and efficient. The parts cost was a few thousand U.S. dollars. This vapor chamber system features low cost, ease of use, and convenient and inexpensive measurement of ethanol vapor concentrations. The lack of a heater and electrical components that could come into contact with ethanol in our case facilitated institutional approval. PMID:22575431

  12. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  13. Pre-clinical research in small animals using radiotherapy technology--a bidirectional translational approach.

    Science.gov (United States)

    Tillner, Falk; Thute, Prasad; Bütof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang

    2014-12-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained. Copyright © 2014. Published by Elsevier GmbH.

  14. Final year veterinary students' attitudes towards small animal dentistry: a questionnaire-based survey.

    Science.gov (United States)

    Perry, R

    2014-09-01

    To investigate the attitudes of final year veterinary students towards small animal dentistry and to examine the teaching received in this subject, both at university and during extra-mural studies. A cross-sectional study of all UK final year veterinary students in 2012 was designed and used by a self-administered Internet-based questionnaire. Six of seven universities participated with 188 student responses. All students felt that it was important or very important for a small animal practitioner to have a broad understanding of dentistry, and that orodental problems were common or very common in small animals. Almost all (99 · 5%) students perceived small animal dentistry as an important or very important subject. Less than 40% of students felt that the teaching had prepared them for entering practice. Over 50% reported that they neither felt confident in discussing orodental problems with clients nor in performing a detailed examination of the oral cavity. Dental problems are perceived by students as frequently encountered in small animal practice. The veterinary surgeon should be adequately trained to detect, diagnose and treat dental disease in small animals and many students feel that their current teaching is inadequate. © 2014 British Small Animal Veterinary Association.

  15. Small-Scale Food Animal Production and Antimicrobial Resistance: Mountain, Molehill, or Something in-between?

    Science.gov (United States)

    Graham, Jay P; Eisenberg, Joseph N S; Trueba, Gabriel; Zhang, Lixin; Johnson, Timothy J

    2017-10-16

    Small-scale food animal production is widely practiced around the globe, yet it is often overlooked in terms of the environmental health risks. Evidence suggests that small-scale food animal producers often employ the use of antimicrobials to improve the survival and growth of their animals, and that this practice leads to the development of antimicrobial resistance (AMR) that can potentially spread to humans. The nature of human-animal interactions in small-scale food animal production systems, generally practiced in and around the home, likely augments spillover events of AMR into the community on a scale that is currently unrecognized and deserves greater attention. https://doi.org/10.1289/EHP2116.

  16. Physical agent modalities in physical therapy and rehabilitation of small animals.

    Science.gov (United States)

    Hanks, June; Levine, David; Bockstahler, Barbara

    2015-01-01

    Physical agent modalities can be effective components of the overall rehabilitation of small animals. This article reviews the effects, indications, contraindications, and precautions of cold, superficial heat, therapeutic ultrasound, and electrical stimulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Carriage of methicillin-resistant Staphylococcus pseudintermedius in small animal veterinarians

    DEFF Research Database (Denmark)

    Paul, Narayan Chandra; Moodley, Arshnee; Ghibaudo, G.

    2011-01-01

    Methicillin-resistant Staphylococcus pseudintermedius (MRSP) is increasingly reported in small animals and cases of human infections have already been described despite its recent emergence in veterinary practice. We investigated the prevalence of MRSP and methicillin-resistant Staphylococcus aur...

  18. Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid Arthritis

    Science.gov (United States)

    2017-10-01

    pre-clinical animal models of autoimmune. For example, FTS can attenuate disease manifestations in experimental autoimmune encephalo- myelitis (34...the clinical score of the disease; however, the biology behind the effect of FTS was not comprehensively elucidated. AIA is an experimental animal ...AWARD NUMBER: W81XWH-14-1-0609 TITLE: Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid

  19. An integrated multimodality image-guided robot system for small-animal imaging research

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Wen-Lin [Department of Radiology, Tzu-Chi University and Radiation Oncology, Buddhist Tzu-Chi General Hospital Hualien, Taiwan (China); Hsin Wu, Tung [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Hsu, Shih-Ming [Department of Biomedical Imaging and Radiological Sciences, China Medical University, Taichung, Taiwan (China); Chen, Chia-Lin [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung, Taiwan (China); Lee, Jason J.S., E-mail: jslee@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Huang, Yung-Hui, E-mail: yhhuang@isu.edu.tw [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung, Taiwan (China)

    2011-10-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO{sub 2} probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153{+-}0.042 mm of desired placement; the phantom simulation errors were within 0.693{+-}0.128 mm. In small-animal studies, the pO{sub 2} probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  20. Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals

    International Nuclear Information System (INIS)

    Lee, Byeong Il; Kim, Hyeon Sik; Jeong, Hye Jin; Lee, Hyung Jae; Moon, Seung Min; Kwon, Seung Young; Jeong, Shin Young; Bom, Hee Seung; Min, Jung Joon; Choi, Eun Seo

    2009-01-01

    Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future

  1. An integrated multimodality image-guided robot system for small-animal imaging research

    International Nuclear Information System (INIS)

    Hsu, Wen-Lin; Hsin Wu, Tung; Hsu, Shih-Ming; Chen, Chia-Lin; Lee, Jason J.S.; Huang, Yung-Hui

    2011-01-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO 2 probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153±0.042 mm of desired placement; the phantom simulation errors were within 0.693±0.128 mm. In small-animal studies, the pO 2 probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  2. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R., E-mail: m_vettorato@hotmail.com [Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2017-11-15

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  3. MRI compatible small animal monitoring and trigger system for whole body scanners

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Karl-Heinz; Krumbein, Ines; Reichenbach, Juergen R. [Jena University Hospital (Germany). Medical Physics Group; Pfeiffer, Norman [Jena University Hospital (Germany). Medical Physics Group; Ernst-Abbe-Fachhochschule Jena (Germany); Herrmann, Lutz [Ernst-Abbe-Fachhochschule Jena (Germany)

    2014-03-01

    Performing magnetic resonance imaging (MRI) experiments with small animals requires continuous monitoring of vital parameters, especially the respiration rate. Clinical whole-body MR scanners represent an attractive option for preclinical imaging as dedicated animal scanners are cost-intensive in both investment and maintenance, thus limiting their availability. Even though impressive image quality is achievable with clinical MR systems in combination with special coils, their built-in physiologic monitoring and triggering units are often not suited for small animal imaging. In this work, we present a simple, MRI compatible low cost solution to monitor the respiration and heart rate of small animals in a clinical whole-body MR scanner. The recording and processing of the biosignals as well as the optimisation of the respiratory trigger generation is described. Additionally rat and mouse in-vivo MRI experiments are presented to illustrate the effectiveness of the monitoring and respiratory trigger system in suppressing motion artifacts. (orig.)

  4. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R.

    2017-01-01

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  5. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  6. State of the art in both in vitro and in vivo aspects of small animal imaging

    International Nuclear Information System (INIS)

    Maziere, B.; Lebars, D.

    2002-01-01

    Full text: In vivo imaging for small animals is dramatically expanding due to the coincidence of mainly three technical factors: 1. the explosion in computer power 2. the enhancement in image processing 3. the accessibility and affordability of digital autoradiography systems and small-animal scanners. Among these imaging techniques let us mention the anatomical imaging techniques such as ultrasonography, X-rays and IRM and the functional imaging radioisotopic techniques SPECT and TEP. The main advantage of the first group of imaging techniques is essentially linked to the high resolution of the anatomical images (with the drawback of the necessity of putting the animal at rest using anaesthesia). The main advantages of SPECT and PET are their high sensitivity and the vast number of functions or metabolism they allow to image. The applications for isotopic functional imaging in small animals are increasing rapidly. Factors contributing to this dramatic expansion include the three previous technical factors plus, at least, three methodological factors: 1. the drug discovery process based on receptor / mechanism of action 2. the increasing number of rodent models of human diseases (SCID mice implanted with human tumors, gene knock-out mice, transgene mice) 3. the advances in isotope and validated tracer availability performances Small animal radioisotopic functional imaging for drug development. In vivo quantification of biological processes to measure the mechanism of action of a potential drug and its concentration at the site of action has become mandatory for developing a drug. Rational and efficient means of confirming mechanisms of action are required. For this purpose, PET and/or SPECT functional - biochemical - molecular imaging in small animals are tools of choice for economical reasons (in the domain of drug development, industry is suffering huge opportunity costs by failing to weed out non-performing new active substances until late phases II and III) and

  7. Recommendations on vaccination for Asian small animal practitioners: a report of the WSAVA Vaccination Guidelines Group.

    Science.gov (United States)

    Day, M J; Karkare, U; Schultz, R D; Squires, R; Tsujimoto, H

    2015-02-01

    In 2012 and 2013, the World Small Animal Veterinary Association (WSAVA) Vaccination Guidelines Group (VGG) undertook fact-finding visits to several Asian countries, with a view to developing advice for small companion animal practitioners in Asia related to the administration of vaccines to dogs and cats. The VGG met with numerous first opinion practitioners, small animal association leaders, academic veterinarians, government regulators and industry representatives and gathered further information from a survey of almost 700 veterinarians in India, China, Japan and Thailand. Although there were substantial differences in the nature and magnitude of the challenges faced by veterinarians in each country, and also differences in the resources available to meet those challenges, overall, the VGG identified insufficient undergraduate and postgraduate training in small companion animal microbiology, immunology and vaccinology. In most of the countries, there has been little academic research into small animal infectious diseases. This, coupled with insufficient laboratory diagnostic support, has limited the growth of knowledge concerning the prevalence and circulating strains of key infectious agents in most of the countries visited. Asian practitioners continue to recognise clinical infections that are now considered uncommon or rare in western countries. In particular, canine rabies virus infection poses a continuing threat to animal and human health in this region. Both nationally manufactured and international dog and cat vaccines are variably available in the Asian countries, but the product ranges are small and dominated by multi-component vaccines with a licensed duration of immunity (DOI) of only 1 year, or no description of DOI. Asian practitioners are largely unaware of current global trends in small animal vaccinology or of the WSAVA vaccination guidelines. Consequently, most practitioners continue to deliver annual revaccination with both core and non

  8. WE-EF-BRA-01: A Dual-Use Optical Tomography System for Small Animal Radiation Research Platform (SARRP)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K; Bin, Z; Wong, J [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Hospital, Baltimore, MD (United States); He, X; Iordachita, I [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD (United States)

    2015-06-15

    Purpose: We develop a novel dual-use configuration for a tri-modality, CBCT/bioluminescence tomography(BLT)/fluorescence tomography(FT), imaging system with the SARRP that can function as a standalone system for longitudinal imaging research and on-board the SARRP to guide irradiation. BLT provides radiation guidance for soft tissue target, while FT offers functional information allowing mechanistic investigations. Methods: The optical assembly includes CCD camera, lens, filter wheel, 3-way mirrors, scanning fiber system and light-tight enclosure. The rotating mirror system directs the optical signal from the animal surface to the camera at multiple projection over 180 degree. The fiber-laser system serves as the external light source for the FT application. Multiple filters are used for multispectral imaging to enhance localization accuracy using BLT. SARRP CBCT provides anatomical information and geometric mesh for BLT/FT reconstruction. To facilitate dual use, the 3-way mirror system is cantilevered in front of the camera. The entire optical assembly is driven by a 1D linear stage to dock onto an independent mouse support bed for standalone application. After completion of on-board optical imaging, the system is retracted from the SARRP to allow irradiation of the mouse. Results: A tissue-simulating phantom and a mouse model with a luminescence light source are used to demonstrate the function of the dual-use optical system. Feasibility data have been obtained based on a manual-docking prototype. The center of mass of light source determined in living mouse with on-board BLT is within 1±0.2mm of that with CBCT. The performance of the motorized system is expected to be the same and will be presented. Conclusion: We anticipate the motorized dual use system provide significant efficiency gain over our manual docking and off-line system. By also supporting off-line longitudinal studies independent of the SARRP, the dual-use system is a highly efficient and cost

  9. Performance of the first Japanese large-scale facility for radon inhalation experiments with small animals

    International Nuclear Information System (INIS)

    Ishimori, Y.; Mitsunobu, F.; Yamaoka, K.; Tanaka, H.; Kataoka, T.; Sakoda, A.

    2011-01-01

    A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects. (authors)

  10. Scalable Electrophysiology in Intact Small Animals with Nanoscale Suspended Electrode Arrays

    OpenAIRE

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Ben W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-01-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires low-throughput and invasive dissections. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the fi...

  11. SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Perks, J; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States); Lucero, S [UC Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

  12. Accessories for detention and protection used in small animals radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, Michel Campos; Vulcano, Luiz Carlos; Fernandes, Marco Antonio Rodrigues

    2016-01-01

    Radiation therapy is a medical method well established in the treatment of cancer in veterinary medicine worldwide. The radiotherapy protocols applied in animals vary according to several factors. In most procedures require sedation or anesthesia of the animal and this fact imposes the use of immobilization accessories specially developed for the different species of animals and treated as their specified procedures. Therefore, this study aims to describe the types of accessories used for immobilization and for the protection of small animals undergoing radiotherapy. For its development a literature search was performed by search sites like Google Scholar, Scielo, Bireme, PubMed, and consultations in books campus library Botucatu UNESP. Despite the limitations of each accessory rated this review, it was possible to identify the use of each and how this can be advantageous for the treatment of animals undergoing radiation therapy. (author)

  13. Development of a SiPM-based PET imaging system for small animals

    International Nuclear Information System (INIS)

    Lu, Yanye; Yang, Kun; Zhou, Kedi; Zhang, Qiushi; Pang, Bo; Ren, Qiushi

    2014-01-01

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development

  14. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation

    International Nuclear Information System (INIS)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Wong, John; Iordachita, Iulian; Siewerdsen, Jeffrey

    2015-01-01

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal (‘tubular’ geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal (‘pancake’ geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry

  15. Image reconstruction for small animal SPECT with two opposing half cones

    Science.gov (United States)

    Zheng, Yibin; Li, Heng; Wang, Jiong; Stolin, Alexander V.; Pole, Joe; Williams, Mark B.

    2007-02-01

    Pinhole imaging is a promising approach for high spatial resolution single gamma emission imaging in situations when the required field of view (FOV) is small, as is the case for small animal imaging. However, all pinhole collimators exhibit steep decrease in sensitivity with increasing angle of incidence from the pinhole axis. This in turn degrades the reconstruction images, and requires higher dose of radiotracer. We developed a novel pinhole SPECT system for small animal imaging which uses two opposing and offset small cone-angle square pinholes, each looking at half of the FOV. This design allows the pinholes to be placed closer to the object and greatly increases detection efficiency and spatial resolution, while not requiring larger size detectors. Iterative image reconstruction algorithms for this system have been developed. Preliminary experimental data have demonstrated marked improvement in contrast and spatial resolution.

  16. Small animal positron emission tomography imaging and in vivo studies of atherosclerosis

    DEFF Research Database (Denmark)

    Hag, Anne Mette Fisker; Ripa, Rasmus Sejersten; Pedersen, Sune Folke

    2013-01-01

    Atherosclerosis is a growing health challenge globally, and despite our knowledge of the disease has increased over the last couple of decades, many unanswered questions remain. As molecular imaging can be used to visualize, characterize and measure biological processes at the molecular and cellu...... knowledge obtained from in vivo positron emission tomography studies of atherosclerosis performed in small animals....

  17. Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging

    NARCIS (Netherlands)

    Prasad, Rameshwar; Zaidi, Habib

    The rapid growth and usage of small-animal positron emission tomography (PET) in molecular imaging research has led to increased demand on PET scanner's time. One potential solution to increase throughput is to scan multiple rodents simultaneously. However, this is achieved at the expense of

  18. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  19. Performance evaluation of a mouse-sized camera for dynamic studies in small animals

    International Nuclear Information System (INIS)

    Loudos, George; Majewski, Stan; Wojcik, Randy; Weisenberger, Andrew; Sakellios, Nicolas; Nikita, Konstantina; Uzunoglu, Nikolaos; Bouziotis, Penelope; Varvarigou, Alexandra

    2007-01-01

    A mouse sized camera has been built in terms of collaboration between the presenting institutions. The system is used for the performance of dynamic studies in small animals, in order to evaluate novel radiopharmaceuticals. The active area of the detector is approximately 48x96 mm allowing depiction of the entire mouse in a single view. The system is based on two flat-panel Hamamatsu H8500 position sensitive photomultiplier tubes (PSPMT), a pixellated NaI(Tl) scintillator and a copper-beryllium (CuBe) parallel-hole collimator. In this work, the evaluation results of the system are presented, using phantoms and small animals injected with conventional radiophrmaceuticals. Average resolution was ∼1.6 mm on the collimator surface and increased to ∼4.1 mm in 12 cm distance from the detector. The average energy resolution was measured and found to be ∼15.6% for Tc 99m . Results from imaging thin capillaries demonstrated system's high resolution and sensitivity in activity variations was shown. Initial dynamic studies have been carried out in small animals injected with Tc 99m -DTPA and Tc 99m -MDP. The results show system's ability to perform kinetic imaging in small animals

  20. Primary functions of the first Japanese large-scale facility for exposing small animals to radon

    International Nuclear Information System (INIS)

    Ishimori, Yuu; Tanaka, Hiroshi; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Kataoka, Takahiro; Sakoda, Akihiro

    2010-01-01

    The Japan Atomic Energy Agency (JAEA) and Okayama University have carried out the experimental animal study and its related studies since 2007 in order to examine the physiological effects of radon in detail. Thus, a radon test facility for small animals was developed in order to increase the statistical certainty of our animal tests. This paper illustrates the performances of that facility, the first large-scale facility of its types in Japan. The facility has a potential of approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups each of which consists of five independent cages. Different radon concentrations in each animal chamber group are available. The major functions of the facility controlling radon and avoiding thoron were shown theoretically and experimentally. The relative standard deviation of radon concentration at the highest concentration group was about 5%, although the lower concentration groups seemed to be affected by variations in background radon. (author)

  1. Development of computational small animal models and their applications in preclinical imaging and therapy research.

    Science.gov (United States)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  2. Development of computational small animal models and their applications in preclinical imaging and therapy research

    International Nuclear Information System (INIS)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future

  3. Development of computational small animal models and their applications in preclinical imaging and therapy research

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB (Netherlands)

    2016-01-15

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  4. Current status and future perspectives of in vivo small animal imaging using radiolabeled nanoparticles

    International Nuclear Information System (INIS)

    Loudos, George; Kagadis, George C.; Psimadas, Dimitris

    2011-01-01

    Small animal molecular imaging is a rapidly expanding efficient tool to study biological processes non-invasively. The use of radiolabeled tracers provides non-destructive, imaging information, allowing time related phenomena to be repeatedly studied in a single animal. In the last decade there has been an enormous progress in related technologies and a number of dedicated imaging systems overcome the limitations that the size of small animal possesses. On the other hand, nanoparticles (NPs) gain increased interest, due to their unique properties, which make them perfect candidates for biological applications. Over the past 5 years the two fields seem to cross more and more often; radiolabeled NPs have been assessed in numerous pre-clinical studies that range from oncology, till HIV treatment. In this article the current status in the tools, applications and trends of radiolabeled NPs reviewed.

  5. Accuracy of measurement of acoustic rhinometry applied to small experimental animals

    DEFF Research Database (Denmark)

    Kaise, Toshihiko; Ukai, Kotara; Pedersen, Ole Finn

    1999-01-01

    Nasal obstruction is one of the major symptoms of allergic rhinitis. In the study of the mechanism of nasal obstruction, experiments on animal are useful. In adult humans, acoustic rhinometry has been used to evaluate nasal obstruction by determining nasal cavity dimensions in terms of cross......-sectional areas as a function of the distance from the nostril. We modified the equipment used on humans to assess dimensions of nasal airway geometry of small experimental animals. The purpose of this study was to investigate the accuracy of measurement of the modified acoustic rhinometry applied to small...... experimental animals using nasal cavity models and guinea pigs. Measurement of the nasal cavity models (made of cylindrical silicone tubes) showed that the acoustic rhinometry estimated 85.5% of actual area and 79.0% of actual volume. In guinea pigs, nasal cavity volume determined by the acoustic rhinometry...

  6. Current status and future perspectives of in vivo small animal imaging using radiolabeled nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Loudos, George, E-mail: gloudos@teiath.gr [Department of Medical Instruments Technology, Technological Educational Institute of Athens, AG. Spyridonos 28, Egaleo 12210 (Greece); Kagadis, George C., E-mail: gkagad@gmail.com [Department of Medical Physics, School of Medicine, University of Patras, P.O. Box 13273, GR-265 04 Rion (Greece); Psimadas, Dimitris, E-mail: dpsimad@chem.uoa.gr [Department of Medical Instruments Technology, Technological Educational Institute of Athens, AG. Spyridonos 28, Egaleo 12210 (Greece); Institute of Radioisotopes and Radiodiagnostic Products, National Center of Scientific Research ' Demokritos' , P.O. 60228, 153 10 Agia Paraskevi, Athens (Greece)

    2011-05-15

    Small animal molecular imaging is a rapidly expanding efficient tool to study biological processes non-invasively. The use of radiolabeled tracers provides non-destructive, imaging information, allowing time related phenomena to be repeatedly studied in a single animal. In the last decade there has been an enormous progress in related technologies and a number of dedicated imaging systems overcome the limitations that the size of small animal possesses. On the other hand, nanoparticles (NPs) gain increased interest, due to their unique properties, which make them perfect candidates for biological applications. Over the past 5 years the two fields seem to cross more and more often; radiolabeled NPs have been assessed in numerous pre-clinical studies that range from oncology, till HIV treatment. In this article the current status in the tools, applications and trends of radiolabeled NPs reviewed.

  7. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  8. Development of a combined microSPECT/CT system for small animal imaging

    Science.gov (United States)

    Sun, Mingshan

    Modern advances in the biomedical sciences have placed increased attention on small animals such as mice and rats as models of human biology and disease in biological research and pharmaceutical development. Their small size and fast breeding rate, their physiologic similarity to human, and, more importantly, the availability of sophisticated genetic manipulations, all have made mice and rats the laboratory mammals of choice in these experimental studies. However, the increased use of small animals in biomedical research also calls for new instruments that can measure the anatomic and metabolic information noninvasively with adequate spatial resolution and measurement sensitivity to facilitate these studies. This dissertation describes the engineering development of a combined single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) system dedicated for small animals imaging. The system aims to obtain both the anatomic and metabolic images with submillimeter spatial resolution in a way that the data can be correlated to provide improved image quality and to offer more complete biological evaluation for biomedical studies involving small animals. The project requires development of complete microSPECT and microCT subsystems. Both subsystems are configured with a shared gantry and animal bed with integrated instrumentation for data acquisition and system control. The microCT employs a microfocus X-ray tube and a CCD-based detector for low noise, high resolution imaging. The microSPECT utilizes three semiconductor detectors coupled with pinhole collimators. A significant contribution of this dissertation project is the development of iterative algorithms with geometrical compensation that allows radionuclide images to be reconstructed at submillimeter spatial resolution, but with significantly higher detection efficiency than conventional methods. Both subsystems are capable of helical scans, offering lengthened field of view and improved

  9. Improving the quality of small animal brain pinhole SPECT imaging by Bayesian reconstruction

    International Nuclear Information System (INIS)

    Sohlberg, Antti; Lensu, Sanna; Jolkkonen, Jukka; Tuomisto, Leena; Ruotsalainen, Ulla; Kuikka, Jyrki T.

    2004-01-01

    The possibility of using existing hardware makes pinhole single-photon emission computed tomography (SPECT) attractive when pursuing the ultra-high resolution required for small animal brain imaging. Unfortunately, the poor sensitivity and the heavy weight of the collimator hamper the use of pinhole SPECT in animal studies by generating noisy and misaligned projections. To improve the image quality we have developed a new Bayesian reconstruction method, pinhole median root prior (PH-MRP), which prevents the excessive noise accumulation from the projections to the reconstructed image. The PH-MRP algorithm was used to reconstruct data acquired with our small animal rotating device, which was designed to reduce the rotation orbit misalignments. Phantom experiments were performed to test the device and compare the PH-MRP with the conventional Feldkamp-Davis-Kress (FDK) and pinhole ordered subsets maximum likelihood expectation maximisation (PH-OSEM) reconstruction algorithms. The feasibility of the system for small animal brain imaging was studied with Han-Wistar rats injected with 123 I-epidepride and 99m Tc-hydroxy methylene diphosphonate. Considering all the experiments, no shape distortions due to orbit misalignments were encountered and remarkable improvements in noise characteristics and also in overall image quality were observed when the PH-MRP was applied instead of the FDK or PH-OSEM. In addition, the proposed methods utilise existing hardware and require only a certain amount of construction and programming work, making them easy to implement. (orig.)

  10. 9.4 T small animal MRI using clinical components for direct translational studies.

    Science.gov (United States)

    Felder, Jörg; Celik, A Avdo; Choi, Chang-Hoon; Schwan, Stefan; Shah, N Jon

    2017-12-28

    Magnetic resonance is a major preclinical and clinical imaging modality ideally suited for longitudinal studies, e.g. in pharmacological developments. The lack of a proven platform that maintains an identical imaging protocol between preclinical and clinical platforms is solved with the construction of an animal scanner based on clinical hard- and software. A small animal magnet and gradient system were connected to a clinical MR system. Several hardware components were either modified or built in-house to achieve compatibility. The clinical software was modified to account for the different field-of-view of a preclinical MR system. The established scanner was evaluated using clinical QA protocols, and platform compatibility for translational research was verified against clinical scanners of different field strength. The constructed animal scanner operates with the majority of clinical imaging sequences. Translational research is greatly facilitated as protocols can be shared between preclinical and clinical platforms. Hence, when maintaining sequences parameters, maximum similarity between pulses played out on a human or an animal system is maintained. Coupling of a small animal magnet with a clinical MR system is a flexible, easy to use way to establish and advance translational imaging capability. It provides cost and labor efficient translational capability as no tedious sequence reprogramming between moieties is required and cross-platform compatibility of sequences facilitates multi-center studies.

  11. Animal production systems of small farms in the Kaski district of Nepal.

    Science.gov (United States)

    Redding, Laurel; Chetri, Dipesh Kumar; Lamichhane, Dirga Kumar; Chay, Yoon; Aldinger, Lauren; Ferguson, James

    2012-10-01

    The aim of this study was to describe animal production on small farms in the Kaski district of Nepal, with the goal of identifying areas where animal health and productivity could be improved. Eighty-five randomly selected farms from four different Village Development Committees were visited. Farmers were interviewed and premises and animals visually inspected on all farms. Feed samples were collected from a subset of farms. The most commonly kept species were water buffalo (used for milk and meat), cattle (used for milk and labor), and goats (used for meat). Average milk production levels were 4.7 kg/day for water buffalo and 1.9 kg/day for cattle. All animals were milked manually, no calves were weaned, and only one farm practiced artificial insemination. A majority of cattle and goats had access to pasture, and a majority of farms fed their working or producing animals concentrates; however, nutritional input was insufficient in terms of energy, protein, and micronutrient content to increase levels of production. Goat-raising was the most profitable endeavor, followed by water buffalo and cattle. We conclude that animals have the potential to contribute significantly to improved livelihoods of farmers in terms of both income generation and non-tangible benefits. However, we found that significant constraints on animal production exist, including insufficient nutritional levels and a lack of preventative care resulting in animal disease. Furthermore, cultural considerations reflecting attitudes toward cattle shape farming in ways that may limit production. Nevertheless, targeted interventions that improve animal health and productivity are possible without being cost prohibitive.

  12. Fungal Infections of the Central Nervous System in Small Animals: Clinical Features, Diagnosis, and Management.

    Science.gov (United States)

    Bentley, R Timothy; Taylor, Amanda R; Thomovsky, Stephanie A

    2018-01-01

    Small animal mycoses vary geographically. Different clinical presentations are seen in animals with infection of the central nervous system (CNS), including multifocal meningoencephalomyelitis, intracranial lesions that accompany sinonasal lesions, rapidly progressive ventriculitis, or solitary granuloma of the brain or spinal cord. Systemic, nasal, or extraneural clinical signs are common but, especially in granuloma cases, do not always occur. Surgery may have a diagnostic and therapeutic role in CNS granuloma. There have been recent advancements in serology. Fluconazole, voriconazole, and posaconazole cross the blood-brain barrier, but voriconazole is neurotoxic to cats. Liposomal and lipid-encapsulated formulations of amphotericin B are preferred. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. FDG small animal PET permits early detection of malignant cells in a xenograft murine model

    International Nuclear Information System (INIS)

    Nanni, Cristina; Spinelli, Antonello; Trespidi, Silvia; Ambrosini, Valentina; Castellucci, Paolo; Farsad, Mohsen; Franchi, Roberto; Fanti, Stefano; Leo, Korinne di; Tonelli, Roberto; Pession, Andrea; Pettinato, Cinzia; Rubello, Domenico

    2007-01-01

    The administration of new anticancer drugs in animal models is the first step from in vitro to in vivo pre-clinical protocols. At this stage it is crucial to ensure that cells are in the logarithmic phase of growth and to avoid vascular impairment, which can cause inhomogeneous distribution of the drug within the tumour and thus lead to bias in the final analysis of efficacy. In subcutaneous xenograft murine models, positivity for cancer is visually recognisable 2-3 weeks after inoculation, when a certain amount of necrosis is usually already present. The aim of this study was to evaluate the accuracy of FDG small animal PET for the early detection of malignant masses in a xenograft murine model of human rhabdomyosarcoma. A second goal was to analyse the metabolic behaviour of this xenograft tumour over time. We studied 23 nude mice, in which 7 x 10 6 rhabdomyosarcoma cells (RH-30 cell line) were injected in the dorsal subcutaneous tissues. Each animal underwent four FDG PET scans (GE, eXplore Vista DR) under gas anaesthesia. The animals were studied 2, 5, 14 and 20 days after inoculation. We administered 20 MBq of FDG via the tail vein. Uptake time was 60 min, and acquisition time, 20 min. Images were reconstructed with OSEM 2D iterative reconstruction and the target to background ratio (TBR) was calculated for each tumour. Normal subcutaneous tissue had a TBR of 0.3. Necrosis was diagnosed when one or more cold areas were present within the mass. All the animals were sacrificed and histology was available to verify PET results. PET results were concordant with the findings of necropsy and histology in all cases. The incidence of the tumour was 69.6% (16/23 animals); seven animals did not develop a malignant mass. Ten of the 23 animals had a positive PET scan 2 days after inoculation. Nine of these ten animals developed a tumour; the remaining animal became negative, at the third scan. The positive predictive value of the early PET scan was 90% (9/10 animals

  14. Anesthesia condition for 18F-FDG imaging of lung metastasis tumors using small animal PET

    International Nuclear Information System (INIS)

    Woo, Sang-Keun; Lee, Tae Sup; Kim, Kyeong Min; Kim, June-Youp; Jung, Jae Ho; Kang, Joo Hyun; Cheon, Gi Jeong; Choi, Chang Woon; Lim, Sang Moo

    2008-01-01

    Small animal positron emission tomography (PET) with 18 F-FDG has been increasingly used for tumor imaging in the murine model. The aim of this study was to establish the anesthesia condition for imaging of lung metastasis tumor using small animal 18 F-FDG PET. Methods: To determine the impact of anesthesia on 18 F-FDG distribution in normal mice, five groups were studied under the following conditions: no anesthesia, ketamine and xylazine (Ke/Xy), 0.5% isoflurane (Iso 0.5), 1% isoflurane (Iso 1) and 2% isoflurane (Iso 2). The ex vivo counting, standard uptake value (SUV) image and glucose SUV of 18 F-FDG in various tissues were evaluated. The 18 F-FDG images in the lung metastasis tumor model were obtained under no anesthesia, Ke/Xy and Iso 0.5, and registered with CT image to clarify the tumor region. Results: Blood glucose concentration and muscle uptake of 18 F-FDG in the Ke/Xy group markedly increased more than in the other groups. The Iso 2 group increased 18 F-FDG uptake in heart compared with the other groups. The Iso 0.5 anesthesized group showed the lowest 18 F-FDG uptake in heart and chest wall. The small size of lung metastasis tumor (2 mm) was clearly visualized by 18 F-FDG image with the Iso 0.5 anesthesia. Conclusion: Small animal 18 F-FDG PET imaging with Iso 0.5 anesthesia was appropriate for the detection of lung metastasis tumor. To acquire 18 F-FDG PET images with small animal PET, the type and level of anesthetic should be carefully considered to be suitable for the visualization of target tissue in the experimental model

  15. Multi-institutional MicroCT image comparison of image-guided small animal irradiators

    Science.gov (United States)

    Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena

    2017-07-01

    To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2  >  0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR  >  36 and noise levels  1.5 lp mm-1 for MTF  =  0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set

  16. SU-E-T-274: Monte Carlo Simulations of Output Factors for a Small Animal Irradiator.

    Science.gov (United States)

    Pidikiti, R; Stojadinovic, S; Song, K; Speiser, M; Solberg, T

    2012-06-01

    Measurement of dosimetric parameters of small photon beams, with field sizes as small 1 mm in diameter, is particularly challenging. This work utilizes Monte Carlo techniques to calculate percent depth dose (PDD) and output factors for small photon fields from a kV x-ray based small animal irradiator. Absolute dose calibration of a commercial small animal stereotactic irradiator (XRAD225, Precision X-ray) was performed in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.4 cm source-to-surface distance (SSD) for a reference collimator 50 mm in diameter. The BEAM/EGS was used to model 225 kV photon beams used for most therapeutic applications. The Monte Carlo model was provided good agreement with measured beam characteristics, e.g. PDD and off-axis ratios. Subsequently, output factors for various square and circular applicators were measured using an ionization chamber and radiochromic film, and compared with MC simulations. Directional Bremsstrahlung splitting (DBS) was utilized for variance reduction to improve efficiency of the output factor simulations. The statistical uncertainty on the MC- calculated results is between 0.5% and 1% for most points. The absolute dose measured for reference collimator at 30.4 cm SSD in water and in air is 4.1 and 4.12 Gy/min. The agreement between simulated and measured output factors was excellent, ranging from 1% to 2.84%. The MC- simulated and measured depth dose data, normalized at the surface, show excellent agreement, with a maximum deviation is approximately 2.5 %. Monte Carlo simulation provides an indispensible tool for validating measurements of the smallest field sizes used in preclinical small animal irradiation. © 2012 American Association of Physicists in Medicine.

  17. A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals

    CERN Document Server

    Loudos, G K; Giokaris, N D; Styliaris, E; Archimandritis, S C; Varvarigou, A D; Papanicolas, C N; Majewski, S; Weisenberger, D; Pani, R; Scopinaro, F; Uzunoglu, N K; Maintas, D; Stefanis, K

    2003-01-01

    The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2 mm in planar and 2-3 mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.

  18. Small animal models to understand pathogenesis of osteoarthritis and use of stem cell in cartilage regeneration.

    Science.gov (United States)

    Piombo, Virginia

    2017-01-01

    Osteoarthritis (OA) is one of the most common diseases, which affect the correct functionality of synovial joints and is characterized by articular cartilage degradation. Limitation in the treatment of OA is mostly due to the very limited regenerative characteristic of articular cartilage once is damaged. Small animal models are of particular importance for mechanistic analysis to understand the processes that affect cartilage degradation. Combination of joint injury techniques with the use of stem cells has been shown to be an important tool for understanding the processes of cartilage degradation and regeneration. Implementation of stem cells and small animal models are important tools to help researchers to find a solution that could ameliorate and prevent the symptoms of OA. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Tumor glucose metabolism imaged in vivo in small animals with whole-body photoacoustic computed tomography

    Science.gov (United States)

    Chatni, Muhammad Rameez; Xia, Jun; Sohn, Rebecca; Maslov, Konstantin; Guo, Zijian; Zhang, Yu; Wang, Kun; Xia, Younan; Anastasio, Mark; Arbeit, Jeffrey; Wang, Lihong V.

    2012-07-01

    With the increasing use of small animals for human disease studies, small-animal whole-body molecular imaging plays an important role in biomedical research. Currently, none of the existing imaging modalities can provide both anatomical and glucose molecular information, leading to higher costs of building dual-modality systems. Even with image co-registration, the spatial resolution of the molecular imaging modality is not improved. Utilizing a ring-shaped confocal photoacoustic computed tomography system, we demonstrate, for the first time, that both anatomy and glucose uptake can be imaged in a single modality. Anatomy was imaged with the endogenous hemoglobin contrast, and glucose metabolism was imaged with a near-infrared dye-labeled 2-deoxyglucose.

  20. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    International Nuclear Information System (INIS)

    Lee, Se Ho; Lee, Seung Wook; Han, Su Chul; Park, Seung Woo

    2016-01-01

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study

  1. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Se Ho; Lee, Seung Wook [Pusan National University, Busan (Korea, Republic of); Han, Su Chul; Park, Seung Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-05-15

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study.

  2. Small animal deworming protocols, client education, and veterinarian perception of zoonotic parasites in western Canada

    Science.gov (United States)

    Stull, Jason W.; Carr, Anthony P.; Chomel, Bruno B.; Berghaus, Roy D.; Hird, David W.

    2007-01-01

    Questionnaires were mailed to veterinarians in western Canada to determine dog and cat deworming protocols and the association between perceived zoonotic risk and perceived prevalence of endoparasites and deworming protocols. Of the responding veterinarians (545), 13% and 39% recommended deworming protocols consistent with established guidelines for puppies and kittens, respectively. Mixed animal practitioners and high-perceived prevalence of Toxocara cati were associated with increased appropriate kitten deworming (P veterinarians noted an established hospital deworming protocol, although only 78% followed the protocol. Forty-four percent of veterinarians stated they discussed with all clients the zoonotic risk of animal-derived endoparasites, whereas the remainder discussed it only under particular circumstances or not at all. Most small animal deworming protocols recommended in western Canada begin too late to inhibit endoparasite shedding. Increased educational efforts directed at veterinarians are warranted. PMID:17436903

  3. Scatter characterization and correction for simultaneous multiple small-animal PET imaging

    OpenAIRE

    Prasad Rameshwar; Zaidi Habib; Zaidi Habib; Zaidi Habib

    2013-01-01

    Purpose: The rapid growth and usage of small animal positron emission tomography (PET) in molecular imaging research has led to increased demand on PET scanner's time. One potential solution to increase throughput is to scan multiple rodents simultaneously. However this is achieved at the expense of deterioration of image quality and loss of quantitative accuracy owing to enhanced effects of photon attenuation and Compton scattering. The purpose of this work is first to characterize the magni...

  4. Development of an ultrahigh resolution Si-PM based PET system for small animals

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Kato, Katsuhiko; Hatazawa, Jun

    2013-11-01

    Since a high resolution PET system is needed for small animal imaging, especially for mouse studies, we developed a new small animal PET system that decreased the size of the scintillators to less than 1 mm. Our developed PET system used 0.5 × 0.7 × 5 mm3 LYSO pixels arranged in an 11 × 13 matrix to form a block with a 0.1 mm BaSO4 reflector between the pixels. Two LYSO blocks were optically coupled to two optical fiber based angled image guides. These LYSO blocks and image guides were coupled to a Si-PM array (Hamamatsu MPPC S11064-050P) to form a block detector. Eight block detectors (16 LYSO blocks) were arranged in a 34 mm inner diameter ring to form a small animal PET system. The block detector showed good separation for the 22 × 13 LYSO pixels in the two-dimensional position histogram. The energy resolution was 20% full-with at half-maximum (FWHM) for 511 keV gamma photons. The transaxial resolution reconstructed by filtered backprojection was 0.71 to 0.75 mm FWHM and the axial resolution was 0.70 mm. The point source sensitivity was 0.24% at the central axial field-of-view. High resolution mouse images were obtained using our PET system. The developed ultrahigh resolution PET system showed attractive images for small animal studies and has a potential to provide new findings in molecular imaging researches.

  5. Development of an ultrahigh resolution Si-PM based PET system for small animals

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Kato, Katsuhiko; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Hatazawa, Jun

    2013-01-01

    Since a high resolution PET system is needed for small animal imaging, especially for mouse studies, we developed a new small animal PET system that decreased the size of the scintillators to less than 1 mm. Our developed PET system used 0.5 × 0.7 × 5 mm 3 LYSO pixels arranged in an 11 × 13 matrix to form a block with a 0.1 mm BaSO 4 reflector between the pixels. Two LYSO blocks were optically coupled to two optical fiber based angled image guides. These LYSO blocks and image guides were coupled to a Si-PM array (Hamamatsu MPPC S11064–050P) to form a block detector. Eight block detectors (16 LYSO blocks) were arranged in a 34 mm inner diameter ring to form a small animal PET system. The block detector showed good separation for the 22 × 13 LYSO pixels in the two-dimensional position histogram. The energy resolution was 20% full-with at half-maximum (FWHM) for 511 keV gamma photons. The transaxial resolution reconstructed by filtered backprojection was 0.71 to 0.75 mm FWHM and the axial resolution was 0.70 mm. The point source sensitivity was 0.24% at the central axial field-of-view. High resolution mouse images were obtained using our PET system. The developed ultrahigh resolution PET system showed attractive images for small animal studies and has a potential to provide new findings in molecular imaging researches. (paper)

  6. Small RNAs in the animal gonad: Guarding genomes and guiding development

    OpenAIRE

    Lau, Nelson C.

    2010-01-01

    Germ cells must safeguard, apportion, package, and deliver their genomes with exquisite precision to ensure proper reproduction and embryonic development. Classical genetic approaches have identified many genes controlling animal germ cell development, but only recently have some of these genes been linked to the RNA interference (RNAi) pathway, a gene silencing mechanism centered on small regulatory RNAs. Germ cells contain microRNAs (miRNAs), endogenous siRNAs (endo-siRNAs), and Piwi-intera...

  7. Factors affecting use of veterinarians by small-scale food animal operations.

    Science.gov (United States)

    Beam, Andrea L; Thilmany, Dawn D; Garber, Lindsey P; Van Metre, David C; Pritchard, Randy W; Kopral, Christine A; Olea-Popelka, Francisco J

    2013-11-01

    To identify factors associated with use of a veterinarian by small-scale food animal operations. Cross-sectional descriptive survey. 16,000 small-scale farm or ranch operations in all 50 states. Surveys were conducted via mail or telephone during 2011 for small-scale operations (gross annual agricultural sales between $10,000 and $499,999) in which an animal or animal product comprised the highest percentage of annual sales. 8,186 (51.2%) operations responded to the survey; 7,849 surveys met the inclusion criteria. For 6,511 (83.0%) operations, beef cattle were the primary animal species. An estimated 82.1% of operations (95% confidence interval [CI], 81.1% to 83.0%) had a veterinarian available ≤ 29 miles away; 1.4% (95% CI, 1.2% to 1.7%) did not have a veterinarian available within 100 miles of the operation. Operations for which the nearest veterinarian was ≥ 100 miles away or for which a veterinarian was not available were located in 40 US states. Overall, 61.7% of operations (95% CI, 60.6% to 62.9%) had used a veterinarian during the 12 months prior to the survey. Producers with college degrees were significantly more likely to use a veterinarian (675%) versus those who did not complete high school (52.9%). Results of this study indicated most small-scale operations had adequate access to veterinarians during 2011, but there seemed to be localized shortages of veterinarians in many states.

  8. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  9. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  10. Near Field UHF RFID Antenna System Enabling the Tracking of Small Laboratory Animals

    Directory of Open Access Journals (Sweden)

    Luca Catarinucci

    2013-01-01

    Full Text Available Radio frequency identification (RFID technology is more and more adopted in a wide range of applicative scenarios. In many cases, such as the tracking of small-size living animals for behaviour analysis purposes, the straightforward use of commercial solutions does not ensure adequate performance. Consequently, both RFID hardware and the control software should be tailored for the particular application. In this work, a novel RFID-based approach enabling an effective localization and tracking of small-sized laboratory animals is proposed. It is mainly based on a UHF Near Field RFID multiantenna system, to be placed under the animals’ cage, and able to rigorously identify the NF RFID tags implanted in laboratory animals (e.g., mice. Once the requirements of the reader antenna have been individuated, the antenna system has been designed and realized. Moreover, an algorithm based on the measured Received Signal Strength Indication (RSSI aiming at removing potential ambiguities in data captured by the multiantenna system has been developed and integrated. The animal tracking system has been largely tested on phantom mice in order to verify its ability to precisely localize each subject and to reconstruct its path. The achieved and discussed results demonstrate the effectiveness of the proposed tracking system.

  11. Dynamic studies of small animals with a four-color diffuse optical tomography imager

    International Nuclear Information System (INIS)

    Schmitz, Christoph H.; Graber, Harry L.; Pei Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu Yong; Barbour, Randall L.

    2005-01-01

    We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals

  12. GATE simulation of a new design of pinhole SPECT system for small animal brain imaging

    International Nuclear Information System (INIS)

    Ozsahin, D. Uzun; Bläckberg, L.; Fakhri, G. El; Sabet, H.

    2017-01-01

    Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.

  13. Real-time 3D motion tracking for small animal brain PET

    Science.gov (United States)

    Kyme, A. Z.; Zhou, V. W.; Meikle, S. R.; Fulton, R. R.

    2008-05-01

    High-resolution positron emission tomography (PET) imaging of conscious, unrestrained laboratory animals presents many challenges. Some form of motion correction will normally be necessary to avoid motion artefacts in the reconstruction. The aim of the current work was to develop and evaluate a motion tracking system potentially suitable for use in small animal PET. This system is based on the commercially available stereo-optical MicronTracker S60 which we have integrated with a Siemens Focus-220 microPET scanner. We present measured performance limits of the tracker and the technical details of our implementation, including calibration and synchronization of the system. A phantom study demonstrating motion tracking and correction was also performed. The system can be calibrated with sub-millimetre accuracy, and small lightweight markers can be constructed to provide accurate 3D motion data. A marked reduction in motion artefacts was demonstrated in the phantom study. The techniques and results described here represent a step towards a practical method for rigid-body motion correction in small animal PET. There is scope to achieve further improvements in the accuracy of synchronization and pose measurements in future work.

  14. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  15. Incorporation of a fluoroscopic X-ray modality in a small animal imaging system

    Energy Technology Data Exchange (ETDEWEB)

    M.S. Saha; E.L. Bradley; Paul Brewer; K.K. Gleason; Brian Kross; Stanislaw Majewski; Vladimir Popov; Jianguo Qian; Amoreena Ranck; K. Smith; Mark Smith; Andrew Weisenberger; Randolph Wojcik; Robert Welsh

    2003-06-01

    The authors have developed a multimodality system for imaging the biodistribution of biologically interesting ligands tagged with /sup 125/I. By incorporating a small fluoroscope as an additional modality, they have enhanced their small animal nuclear imaging system to include both X-rays and images from two Hamamatsu R3292 5'' diameter position sensitive photomultiplier tubes (PSPMT) viewing pixelated scintillators with image co-registration of 1.5 mm or better. Collimators placed between the animal and the scintillators can easily be interchanged and include CuBe parallel-hole collimators with a range of resolution and sensitivity combinations. The small X-ray fluoroscope provides 5 cm diameter images, several of which can readily be combined to provide structural anatomical information from the animal under study. The system has been tested by comparing the uptake of /sup 125/I (in NaI) in control mice and mice previously fed a solution of KI (potassium iodide) designed specific.

  16. Towards a high sensitivity small animal PET system based on CZT detectors (Conference Presentation)

    Science.gov (United States)

    Abbaszadeh, Shiva; Levin, Craig

    2017-03-01

    Small animal positron emission tomography (PET) is a biological imaging technology that allows non-invasive interrogation of internal molecular and cellular processes and mechanisms of disease. New PET molecular probes with high specificity are under development to target, detect, visualize, and quantify subtle molecular and cellular processes associated with cancer, heart disease, and neurological disorders. However, the limited uptake of these targeted probes leads to significant reduction in signal. There is a need to advance the performance of small animal PET system technology to reach its full potential for molecular imaging. Our goal is to assemble a small animal PET system based on CZT detectors and to explore methods to enhance its photon sensitivity. In this work, we reconstruct an image from a phantom using a two-panel subsystem consisting of six CZT crystals in each panel. For image reconstruction, coincidence events with energy between 450 and 570 keV were included. We are developing an algorithm to improve sensitivity of the system by including multiple interaction events.

  17. ESTRO ACROP: Technology for precision small animal radiotherapy research: Optimal use and challenges.

    Science.gov (United States)

    Verhaegen, Frank; Dubois, Ludwig; Gianolini, Stefano; Hill, Mark A; Karger, Christian P; Lauber, Kirsten; Prise, Kevin M; Sarrut, David; Thorwarth, Daniela; Vanhove, Christian; Vojnovic, Boris; Weersink, Robert; Wilkens, Jan J; Georg, Dietmar

    2018-03-01

    Many radiotherapy research centers have recently installed novel research platforms enabling the investigation of the radiation response of tumors and normal tissues in small animal models, possibly in combination with other treatment modalities. Many more research institutes are expected to follow in the coming years. These novel platforms are capable of mimicking human radiotherapy more closely than older technology. To facilitate the optimal use of these novel integrated precision irradiators and various small animal imaging devices, and to maximize the impact of the associated research, the ESTRO committee on coordinating guidelines ACROP (Advisory Committee in Radiation Oncology Practice) has commissioned a report to review the state of the art of the technology used in this new field of research, and to issue recommendations. This report discusses the combination of precision irradiation systems, small animal imaging (CT, MRI, PET, SPECT, bioluminescence) systems, image registration, treatment planning, and data processing. It also provides guidelines for reporting on studies. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  19. A 3D HIDAC-PET camera with sub-millimeter resolution for imaging small animals

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Chandler, R.A.; Dettmar, C.A.R.

    1999-01-01

    A HIDAC-PET camera consisting essentially of 5 million 0.5 mm gas avalanching detectors has been constructed for small-animal imaging. The particular HIDAC advantage--a high 3D spatial resolution--has been improved to 0.95 mm fwhm and to 0.7 mm fwhm when reconstructing with 3D-OSEM methods incorporating resolution recovery. A depth-of-interaction resolution of 2.5 mm is implicit, due to the laminar construction. Scatter-corrected sensitivity, at 8.9 cps/kBq (i.e. 0.9%) from a central point source, or 7.2 cps/kBq (543 cps/kBq/cm 3 ) from a distributed (40 mm diameter, 60 mm long) source is now much higher than previous, and other, work. A field-of-view of 100 mm (adjustable to 200 mm) diameter by 210 mm axially permits whole-body imaging of small animals, containing typically 4MBqs of activity, at 40 kcps of which 16% are random coincidences, with a typical scatter fraction of 44%. Throughout the field-of-view there are no positional distortions and relative quantitation is uniform to ± 3.5%, but some variation of spatial resolution is found. The performance demonstrates that HIDAC technology is quite appropriate for small-animal PET cameras

  20. Geo-PET: A novel generic organ-pet for small animal organs and tissues

    Science.gov (United States)

    Sensoy, Levent

    Reconstructed tomographic image resolution of small animal PET imaging systems is improving with advances in radiation detector development. However the trend towards higher resolution systems has come with an increase in price and system complexity. Recent developments in the area of solid-state photomultiplication devices like silicon photomultiplier arrays (SPMA) are creating opportunities for new high performance tools for PET scanner design. Imaging of excised small animal organs and tissues has been used as part of post-mortem studies in order to gain detailed, high-resolution anatomical information on sacrificed animals. However, this kind of ex-vivo specimen imaging has largely been limited to ultra-high resolution muCT. The inherent limitations to PET resolution have, to date, excluded PET imaging from these ex-vivo imaging studies. In this work, we leverage the diminishing physical size of current generation SPMA designs to create a very small, simple, and high-resolution prototype detector system targeting ex-vivo tomographic imaging of small animal organs and tissues. We investigate sensitivity, spatial resolution, and the reconstructed image quality of a prototype small animal PET scanner designed specifically for imaging of excised murine tissue and organs. We aim to demonstrate that a cost-effective silicon photomultiplier (SiPM) array based design with thin crystals (2 mm) to minimize depth of interaction errors might be able to achieve sub-millimeter resolution. We hypothesize that the substantial decrease in sensitivity associated with the thin crystals can be compensated for with increased solid angle detection, longer acquisitions, higher activity and wider acceptance energy windows (due to minimal scatter from excised organs). The constructed system has a functional field of view (FoV) of 40 mm diameter, which is adequate for most small animal specimen studies. We perform both analytical (3D-FBP) and iterative (ML-EM) methods in order to

  1. A Novel Restraining Device for Small Animal Imaging Exams: Validation in Rabbits

    Directory of Open Access Journals (Sweden)

    Carlos Henrique Barbosa

    2015-01-01

    Full Text Available Objective. To develop, validate, and patent a Restraining Device for Small Animal Imaging Exams (RDSAIE that allows exams to be comfortably conducted without risks to animals and professionals. Methods. A RDSAIE with a mobile cover and shelf was built with transparent acrylic material. A total of six anesthetized rabbits were used to perform the following imaging exams of the skull: Cone Beam Computed Tomography, Magnetic Resonance Imaging, and Scintigraphy. Results. The device showed great functionality and full visibility of the animal behavior, which remained fully stabilized and immobilized in either the horizontal or vertical position without the need for a person to remain in the test room to assist them. The procedures were performed without difficulty, and images of good resolution and without artifacts were obtained. Conclusion. The RDSAIE is comfortable, safe, efficient, and ergonomic. It allows the easy placement of animals in different body positions, including the vertical, the maintenance of postural stability, and full visibility. It may be constructed for animals heavier than 4 kg and it is adaptable for translational studies in anima nobile.

  2. Optimal energy window selection of a CZT-based small-animal SPECT for quantitative accuracy

    International Nuclear Information System (INIS)

    Park, Su-Jin; Yu, A. Ram; Choi, Yun Young; Kim, Kyeong Min; Kim, Hee-Joung

    2015-01-01

    Cadmium zinc telluride (CZT)-based small-animal single-photon emission computed tomography (SPECT) has desirable characteristics such as superior energy resolution, but data acquisition for SPECT imaging has been widely performed with a conventional energy window. The aim of this study was to determine the optimal energy window settings for technetium-99 m ( 99m Tc) and thallium-201 ( 201 Tl), the most commonly used isotopes in SPECT imaging, using CZT-based small-animal SPECT for quantitative accuracy. We experimentally investigated quantitative measurements with respect to primary count rate, contrast-to-noise ratio (CNR), and scatter fraction (SF) within various energy window settings using Triumph X-SPECT. The two ways of energy window settings were considered: an on-peak window and an off-peak window. In the on-peak window setting, energy centers were set on the photopeaks. In the off-peak window setting, the ratios of energy differences between the photopeak from the lower- and higher-threshold varied from 4:6 to 3:7. In addition, the energy-window width for 99m Tc varied from 5% to 20%, and that for 201 Tl varied from 10% to 30%. The results of this study enabled us to determine the optimal energy windows for each isotope in terms of primary count rate, CNR, and SF. We selected the optimal energy window that increases the primary count rate and CNR while decreasing SF. For 99m Tc SPECT imaging, the energy window of 138–145 keV with a 5% width and off-peak ratio of 3:7 was determined to be the optimal energy window. For 201 Tl SPECT imaging, the energy window of 64–85 keV with a 30% width and off-peak ratio of 3:7 was selected as the optimal energy window. Our results demonstrated that the proper energy window should be carefully chosen based on quantitative measurements in order to take advantage of desirable characteristics of CZT-based small-animal SPECT. These results provided valuable reference information for the establishment of new protocol for

  3. Optimal energy window selection of a CZT-based small-animal SPECT for quantitative accuracy

    Science.gov (United States)

    Park, Su-Jin; Yu, A. Ram; Choi, Yun Young; Kim, Kyeong Min; Kim, Hee-Joung

    2015-05-01

    Cadmium zinc telluride (CZT)-based small-animal single-photon emission computed tomography (SPECT) has desirable characteristics such as superior energy resolution, but data acquisition for SPECT imaging has been widely performed with a conventional energy window. The aim of this study was to determine the optimal energy window settings for technetium-99 m (99mTc) and thallium-201 (201Tl), the most commonly used isotopes in SPECT imaging, using CZT-based small-animal SPECT for quantitative accuracy. We experimentally investigated quantitative measurements with respect to primary count rate, contrast-to-noise ratio (CNR), and scatter fraction (SF) within various energy window settings using Triumph X-SPECT. The two ways of energy window settings were considered: an on-peak window and an off-peak window. In the on-peak window setting, energy centers were set on the photopeaks. In the off-peak window setting, the ratios of energy differences between the photopeak from the lower- and higher-threshold varied from 4:6 to 3:7. In addition, the energy-window width for 99mTc varied from 5% to 20%, and that for 201Tl varied from 10% to 30%. The results of this study enabled us to determine the optimal energy windows for each isotope in terms of primary count rate, CNR, and SF. We selected the optimal energy window that increases the primary count rate and CNR while decreasing SF. For 99mTc SPECT imaging, the energy window of 138-145 keV with a 5% width and off-peak ratio of 3:7 was determined to be the optimal energy window. For 201Tl SPECT imaging, the energy window of 64-85 keV with a 30% width and off-peak ratio of 3:7 was selected as the optimal energy window. Our results demonstrated that the proper energy window should be carefully chosen based on quantitative measurements in order to take advantage of desirable characteristics of CZT-based small-animal SPECT. These results provided valuable reference information for the establishment of new protocol for CZT

  4. Optimal energy window selection of a CZT-based small-animal SPECT for quantitative accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su-Jin [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju 220-710 (Korea, Republic of); Yu, A. Ram [Laboratory animal center, OSONG Medical Innovation Foundation, Chunguk 363-951 (Korea, Republic of); Department of Nuclear Medicine, College of Medicine, Hanyang University Hospital, Seoul 133-792 (Korea, Republic of); Choi, Yun Young [Department of Nuclear Medicine, College of Medicine, Hanyang University Hospital, Seoul 133-792 (Korea, Republic of); Kim, Kyeong Min [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Kim, Hee-Joung, E-mail: hjk1@yonsei.ac.kr [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju 220-710 (Korea, Republic of)

    2015-05-11

    Cadmium zinc telluride (CZT)-based small-animal single-photon emission computed tomography (SPECT) has desirable characteristics such as superior energy resolution, but data acquisition for SPECT imaging has been widely performed with a conventional energy window. The aim of this study was to determine the optimal energy window settings for technetium-99 m ({sup 99m}Tc) and thallium-201 ({sup 201}Tl), the most commonly used isotopes in SPECT imaging, using CZT-based small-animal SPECT for quantitative accuracy. We experimentally investigated quantitative measurements with respect to primary count rate, contrast-to-noise ratio (CNR), and scatter fraction (SF) within various energy window settings using Triumph X-SPECT. The two ways of energy window settings were considered: an on-peak window and an off-peak window. In the on-peak window setting, energy centers were set on the photopeaks. In the off-peak window setting, the ratios of energy differences between the photopeak from the lower- and higher-threshold varied from 4:6 to 3:7. In addition, the energy-window width for {sup 99m}Tc varied from 5% to 20%, and that for {sup 201}Tl varied from 10% to 30%. The results of this study enabled us to determine the optimal energy windows for each isotope in terms of primary count rate, CNR, and SF. We selected the optimal energy window that increases the primary count rate and CNR while decreasing SF. For {sup 99m}Tc SPECT imaging, the energy window of 138–145 keV with a 5% width and off-peak ratio of 3:7 was determined to be the optimal energy window. For {sup 201}Tl SPECT imaging, the energy window of 64–85 keV with a 30% width and off-peak ratio of 3:7 was selected as the optimal energy window. Our results demonstrated that the proper energy window should be carefully chosen based on quantitative measurements in order to take advantage of desirable characteristics of CZT-based small-animal SPECT. These results provided valuable reference information for the

  5. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  6. Experimental small bowel transplantation from non-heart-beating donors: a large-animal study.

    Science.gov (United States)

    Cobianchi, L; Zonta, S; Vigano, J; Dominioni, T; Ciccocioppo, R; Morbini, P; Bottazzi, A; Mazzilli, M; De Martino, M; Vicini, E; Filisetti, C; Botrugno, I; Dionigi, P; Alessiani, M

    2009-01-01

    The shortage of organs in the last 20 years is stimulating the development of new strategies to expand the pool of donors. The harvesting of a graft from non-heart-beating donors (NHBDs) has been successfully proposed for kidney and liver transplantation. To our knowledge, no studies are available for small bowel transplantation using NHBDs. In an experimental setting of small bowel transplantation, we studied the feasibility of using intestinal grafts retrieved from NHBDs. Twenty five Large White piglets underwent total orthotopic small bowel transplantation and were randomly divided as follow: NHBD group (n = 15) received grafts from NHBDs; heart-beating donor (HBD) group (n = 10) received grafts from HBDs. The NHBD pigs were sacrificed inducing the cardiac arrest by a lethal potassium injection. After 20 minutes (no touch period = warm ischemia), they underwent cardiac massage, laparotomy, and aorta cannulation for flushing and cooling the abdominal organs. In HBDs, the cardiac arrest was induced at the time of organ cold perfusion. In both groups, immunosuppression was based on tacrolimus oral monotherapy. The animals were observed for 30 days. The graft absorptive function was studied at day 30 using the D-xylose absorption test. Histological investigation included HE (Hematoxilin and Eosin) microscopical analysis and immunohistological staining. Animals in the NHBD group died due to infection (n = 3), acute cellular rejection (n = 2), technical complications (n = 2), and intestinal failure (n = 8). In the HBD group, all animals but two were alive at the end of the study. The D-xylose absorption was significantly lower among the NHBD compared with the HBD group (P intestinal mucosa is sensitive to ischemic injury. When the intestinal graft is harvested from NHBDs, the infectious-related mortality was higher and the absorptive function lower. Histological examination confirmed a higher grade of ischemic injury in the NHBD grafts that correlated with the

  7. The evaluation of 6 and 18 MeV electron beams for small animal irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chao, T C; Tu, S J; Tung, C J; Hong, J H; Lee, C C [Department of Medical Imaging and Radiological Science, Chang Gung University, 259 Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan (China); Chen, A M [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 300, Taiwan (China)], E-mail: cclee@mail.cgu.edu.tw

    2009-10-07

    A small animal irradiator is critical for providing optimal radiation dose distributions for pre-clinical animal studies. This paper focuses on the evaluation of using 6 or 18 MeV electron beams as small animal irradiators. Compared with all other prototypes which use photons to irradiate small animals, an electron irradiator has many advantages in its shallow dose distribution. Two major approaches including simulation and measurement were used to evaluate the feasibility of applying electron beams in animal irradiation. These simulations and measurements were taken in three different fields (a 6 cm x 6 cm square field, and 4 mm and 30 mm diameter circular fields) and with two different energies (6 MeV and 18 MeV). A PTW Semiflex chamber in a PTW-MP3 water tank, a PTW Markus chamber type 23343, a PTW diamond detector type 60003 and KODAK XV films were used to measure PDDs, lateral beam profiles and output factors for either optimizing parameters of Monte Carlo simulation or to verify Monte Carlo simulation in small fields. Results show good agreement for comparisons of percentage depth doses ({<=}2.5% for 6 MeV e; {<=}1.8% for 18 MeV e) and profiles (FWHM {<=} 0.5 mm) between simulations and measurements on the 6 cm field. Greater deviation can be observed in the 4 mm field, which is mainly caused by the partial volume effects of the detectors. The FWHM of the profiles for the 18 MeV electron beam is 32.6 mm in the 30 mm field, and 4.7 mm in the 4 mm field at d{sub 90}. It will take 1-13 min to complete one irradiation of 5-10 Gy. In addition, two different digital phantoms were also constructed, including a homogeneous cylindrical water phantom and a CT-based heterogeneous mouse phantom, and were implemented into Monte Carlo to simulate dose distribution with different electron irradiations.

  8. The risk of death: the confidential enquiry into perioperative small animal fatalities.

    Science.gov (United States)

    Brodbelt, David C; Blissitt, Karen J; Hammond, Richard A; Neath, Prue J; Young, Lestey E; Pfeiffer, Dirk U; Wood, James L N

    2008-09-01

    To estimate the risks of anaesthetic and sedation-related mortality in companion animals in the UK. (The Confidential Enquiry into Perioperative Small Animal Fatalities, CEPSAF). A prospective cohort study with nested case-control study. All small animals anaesthetized and sedated at participating centres between June 2002 and June 2004. Patient outcomes at 48 hours (alive, dead and killed) were recorded. Anaesthetic and sedation-related death was defined as death where surgical or pre-existing medical causes did not solely cause death. Species-specific risks of anaesthetic-related death and 95% confidence intervals (95% CI) were calculated. Risks were also estimated in the sub-sets of dogs, cats and rabbits that were either healthy or sick (ASA 1-2 and 3-5, respectively). One hundred and seventeen veterinary practices participated in the study and 98 036 dogs, 79 178 cats and 8209 rabbits were anaesthetized and sedated. Overall risks of anaesthetic and sedation-related death in dogs were 0.17% (1 in 601, 95% CI 0.14-0.19%), in cats 0.24% (1 in 419, 95% CI 0.20-0.27%) and in rabbits 1.39% (1 in 72, 95% CI 1.14-1.64%) within 48 hours of the procedure. In healthy dogs, cats and rabbits, the risks were estimated to be 0.05% (1 in 1849, 95% CI 0.04-0.07%), 0.11%, (1 in 895, 95% CI 0.09-0.14%) and 0.73% (1 in 137, 95% CI 0.54-0.93%), respectively. In sick dogs, cats and rabbits, the risks were 1.33%, (1 in 75, 95% CI 1.07-1.60%), 1.40% (1 in 71, 95% CI 1.12-1.68%) and 7.37% (1 in 14, 95% CI 5.20-9.54%), respectively. Postoperative deaths accounted for 47% of deaths in dogs, 61% in cats and 64% in rabbits. Most other small animal species had higher mortality risks. Small animal anaesthesia appears to be increasingly safe. Greater patient care in the postoperative period could reduce fatalities.

  9. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  10. Design of small-animal thermal neutron irradiation facility at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Liu, H.B.

    1996-01-01

    The broad beam facility (BBF) at the Brookhaven Medical Research Reactor (BMRR) can provide a thermal neutron beam with flux intensity and quality comparable to the beam currently used for research on neutron capture therapy using cell-culture and small-animal irradiations. Monte Carlo computations were made, first, to compare with the dosimetric measurements at the existing BBF and, second, to calculate the neutron and gamma fluxes and doses expected at the proposed BBF. Multiple cell cultures or small animals could be irradiated simultaneously at the so-modified BBF under conditions similar to or better than those individual animals irradiated at the existing thermal neutron irradiation Facility (TNIF) of the BMRR. The flux intensity of the collimated thermal neutron beam at the proposed BBF would be 1.7 x 10 10 n/cm 2 ·s at 3-MW reactor power, the same as at the TNIF. However, the proposed collimated beam would have much lower gamma (0.89 x 10 -11 cGy·cm 2 /n th ) and fast neutron (0.58 x 10 -11 cGy·cm 2 /n th ) contaminations, 64 and 19% of those at the TNIF, respectively. The feasibility of remodeling the facility is discussed

  11. Analysis of plant-derived miRNAs in animal small RNA datasets

    Directory of Open Access Journals (Sweden)

    Zhang Yuanji

    2012-08-01

    Full Text Available Abstract Background Plants contain significant quantities of small RNAs (sRNAs derived from various sRNA biogenesis pathways. Many of these sRNAs play regulatory roles in plants. Previous analysis revealed that numerous sRNAs in corn, rice and soybean seeds have high sequence similarity to animal genes. However, exogenous RNA is considered to be unstable within the gastrointestinal tract of many animals, thus limiting potential for any adverse effects from consumption of dietary RNA. A recent paper reported that putative plant miRNAs were detected in animal plasma and serum, presumably acquired through ingestion, and may have a functional impact in the consuming organisms. Results To address the question of how common this phenomenon could be, we searched for plant miRNAs sequences in public sRNA datasets from various tissues of mammals, chicken and insects. Our analyses revealed that plant miRNAs were present in the animal sRNA datasets, and significantly miR168 was extremely over-represented. Furthermore, all or nearly all (>96% miR168 sequences were monocot derived for most datasets, including datasets for two insects reared on dicot plants in their respective experiments. To investigate if plant-derived miRNAs, including miR168, could accumulate and move systemically in insects, we conducted insect feeding studies for three insects including corn rootworm, which has been shown to be responsive to plant-produced long double-stranded RNAs. Conclusions Our analyses suggest that the observed plant miRNAs in animal sRNA datasets can originate in the process of sequencing, and that accumulation of plant miRNAs via dietary exposure is not universal in animals.

  12. Pain control in small animalsControle da dor em pequenos animais

    Directory of Open Access Journals (Sweden)

    Julia Duarte Penter

    2011-12-01

    Full Text Available Pain is an unpleasant sensory or emotional experience that follows the application of a noxious stimulus. Can be experienced with or without the concomitant occurrence of physical stress signs, which occurs frequently in animals caused by trauma, systemic disease or surgical procedures. The control depends on length, where there are painful impulses and mental status of the animal. It is an important clinical condition, resulting in suffer that will affect quality life. This paper is a review of pathophysiology and pain control in small animals.A dor é uma experiência sensorial ou emocional desagradável que se segue à aplicação de um estímulo nocivo. Pode ser vivenciada com ou sem o acontecimento concomitante de sinais físicos de estresse, trauma, doença sistêmica ou procedimento cirúrgico. Seu controle depende de sua duração, de onde surgem os impulsos dolorosos e do estado de consciência do animal. É uma condição clinicamente importante, que resulta em sofrimento e afeta a qualidade de vida dos animais. O objetivo deste trabalho é a revisão da fisiopatologia e controle da dor em pequenos animais.

  13. A new low-turbulence wind tunnel for animal and small vehicle flight experiments

    Science.gov (United States)

    Quinn, Daniel B.; Watts, Anthony; Nagle, Tony; Lentink, David

    2017-03-01

    Our understanding of animal flight benefits greatly from specialized wind tunnels designed for flying animals. Existing facilities can simulate laminar flow during straight, ascending and descending flight, as well as at different altitudes. However, the atmosphere in which animals fly is even more complex. Flow can be laminar and quiet at high altitudes but highly turbulent near the ground, and gusts can rapidly change wind speed. To study flight in both laminar and turbulent environments, a multi-purpose wind tunnel for studying animal and small vehicle flight was built at Stanford University. The tunnel is closed-circuit and can produce airspeeds up to 50 m s-1 in a rectangular test section that is 1.0 m wide, 0.82 m tall and 1.73 m long. Seamless honeycomb and screens in the airline together with a carefully designed contraction reduce centreline turbulence intensities to less than or equal to 0.030% at all operating speeds. A large diameter fan and specialized acoustic treatment allow the tunnel to operate at low noise levels of 76.4 dB at 20 m s-1. To simulate high turbulence, an active turbulence grid can increase turbulence intensities up to 45%. Finally, an open jet configuration enables stereo high-speed fluoroscopy for studying musculoskeletal control in turbulent flow.

  14. A new low-turbulence wind tunnel for animal and small vehicle flight experiments.

    Science.gov (United States)

    Quinn, Daniel B; Watts, Anthony; Nagle, Tony; Lentink, David

    2017-03-01

    Our understanding of animal flight benefits greatly from specialized wind tunnels designed for flying animals. Existing facilities can simulate laminar flow during straight, ascending and descending flight, as well as at different altitudes. However, the atmosphere in which animals fly is even more complex. Flow can be laminar and quiet at high altitudes but highly turbulent near the ground, and gusts can rapidly change wind speed. To study flight in both laminar and turbulent environments, a multi-purpose wind tunnel for studying animal and small vehicle flight was built at Stanford University. The tunnel is closed-circuit and can produce airspeeds up to 50 m s -1 in a rectangular test section that is 1.0 m wide, 0.82 m tall and 1.73 m long. Seamless honeycomb and screens in the airline together with a carefully designed contraction reduce centreline turbulence intensities to less than or equal to 0.030% at all operating speeds. A large diameter fan and specialized acoustic treatment allow the tunnel to operate at low noise levels of 76.4 dB at 20 m s -1 . To simulate high turbulence, an active turbulence grid can increase turbulence intensities up to 45%. Finally, an open jet configuration enables stereo high-speed fluoroscopy for studying musculoskeletal control in turbulent flow.

  15. Application study of the optical biopsy system for small experimental animals

    Science.gov (United States)

    Sato, Hidetoshi; Suzuki, Toshiaki; Morita, Shin-ichi; Maruyama, Atsushi; Shimosegawa, Toru; Matsuura, Yuji; Kanai, Gen'ichi; Ura, Nobuo; Masutani, Koji; Ozaki, Yukihiro

    2008-02-01

    An optical biopsy system for small experimental animals has been developed. The system includes endoscope probe, portable probe and two kinds of miniaturized Raman probes. The micro Raman probe (MRP) is made of optical fibers and the ball lens hollow optical fiber Raman probe (BHRP) is made of hollow fiber. The former has large focal depth and suitable to measure average spectra of subsurface tissue. The latter has rather small focal depth and it is possible to control focal length by selecting ball lens attached at the probe head. It is suitable to survey materials at the fixed depth in the tissue. The system is applied to study various small animal cancer models, such as esophagus and stomach rat models and subcutaneous mouse models of pancreatic cancers. In the studies of subcutaneous tumor model mouse, it is suggested that protein conformational changes occur in the tumor tissue within few minutes after euthanasia of the mouse. No more change is observed for the following ten minutes. Any alterations in the molecular level are not observed in normal skin, muscle tissues. Since the change completes in such a short time, it is suggested that this phenomenon caused by termination of blood circulation.

  16. A small animal model of human Helicobacter pylori active chronic gastritis.

    Science.gov (United States)

    Lee, A; Fox, J G; Otto, G; Murphy, J

    1990-11-01

    Isolation of a spiral-shaped bacterium closely related to Helicobacter pylori from the cat stomach made it possible to investigate new small animal models of gastric infection. Pure cultures of this bacterium, provisionally named "Helicobacter felis," were fed to germ-free mice. The organism colonized the stomach in large numbers in mucus and deep in the gastric pits and showed the same gastric trophism found with H. pylori. Significant histopathology was seen in all H. felis-infected mice. At 2 weeks postinfection, an acute inflammatory response was seen composed primarily of eosinophils and neutrophils. At 3 weeks, the polymorphonuclear response was more pronounced with large numbers of neutrophils in some areas forming small microabscesses. Lymphocytes also increased in number. By 8 weeks, several relatively large lymphoid nodules were present in the submucosa. Multiple small microabscesses were still present in the pyloric mucosa. This is the first animal model of bacterial gastritis to be described that shows progression from acute inflammation to persistent acute on chronic inflammation (active chronic) as is seen in human infection with H. pylori.

  17. Continuing Veterinary Medical Education Needs Assessment of Small Animal Practitioners in South Korea.

    Science.gov (United States)

    Chun, Myung-Sun; Hwang, Cheol-Yong

    2015-01-01

    This first survey of small animal veterinarians in Korea explores demographic patterns, previous learning experiences, and program preferences for continuing veterinary medical education (CVME). Data were analyzed to identify and describe learning needs and preferences. Respondents' average CVME hours (38.4 hours/year) exceeded the mandatory 10 hours per year. Almost all respondents recognized the importance of CVME. Lack of time and travel distance were identified as significant barriers to CVME participation. CVME courses scheduled after 9 p.m. on weekdays with a registration fee of up to $50 US per hour were preferred. Respondents clearly defined the educational quality criteria of preferred CVME programs: delivery in a series of interventions in a small seminar format, with lectures on theory combined with practical skill-building wet labs taught by experienced veterinarians and board-certified specialists. Small animal veterinarians in Korea are enthusiastic life-long learners who are strongly motivated to select CVME learning activities based on self-identified needs. The changing environment of veterinary medicine in Korea demands an evolution of CVME quality criteria, such as clear program goals reflecting veterinarians' educational needs and desirable competencies, and specific measurable learning objectives. Moreover, the current accreditation system, which does not encourage hands-on skill development formats, needs urgent improvement.

  18. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  19. Effect of ultra-high pressure on small animals, tardigrades and Artemia

    Directory of Open Access Journals (Sweden)

    Fumihisa Ono

    2016-12-01

    Full Text Available This research shows that small animals, tardigrades (Milnesium tardigradum in tun (dehydrated state and Artemia salina cists (dried eggs can tolerate the very high hydrostatic pressure of 7.5 GPa. It was really surprising that living organisms can survive after exposure to such a high pressure. We extended these studies to the extremely high pressure of 20 GPa by using a Kawai-type octahedral anvil press. After exposure to this pressure for 30 min, the tardigrades were soaked in pure water and investigated under a microscope. Their bodies regained metabolic state and no serious injury could be seen. But they were not alive. A few of Artemia eggs went part of the way to hatching after soaked in sea water, but they never grew any further. Comparing with the case of blue-green alga, these animals are weaker under ultra-high pressure.

  20. [The small pox vaccine: its first century in Brazil (from the Jennerian to the animal vaccine)].

    Science.gov (United States)

    Fernandes, T

    1999-01-01

    Covering a period of roughly hundred years, the article looks at some of the more meaningful events during the period in which the small pox vaccine was institutionalized in Brazil. Discoveries and discussions then taking place in other countries are also examined, particularly as they influenced Brazil. The process is followed from introduction of the human vaccine to the arrival of the animal vaccine and creation of the Municipal Vaccine Institute--a private initative by physician Pedro Affonso Franco, also known as the barao de Pedro Affonso. Adoption of the animal vaccine not only represented progress in controlling the disease but also spurred discussions that saw medical and political groups in Brazil taking sides with either Oswaldo Cruz or the barao de Pedro Affonso. The debate continued within the academic and political arenas until the Vaccine Institute was made part of the Manguinhos laboratories.

  1. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    Science.gov (United States)

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  2. Biological X-ray irradiator characterization for use with small animals and cells

    Directory of Open Access Journals (Sweden)

    A. Colello Bruno

    Full Text Available This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current, the radiometric survey (leakage radiation and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1 and remained stable for long (constant and short (repeatability intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer. The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators for cells and small animal irradiation, especially in early research stages.

  3. Fully automated intrinsic respiratory and cardiac gating for small animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, J; Baeuerle, T; Semmler, W; Bartling, S H [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Dinkel, J [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Zwick, S [Department of Diagnostic Radiology, Medical Physics, Freiburg University (Germany); Grasruck, M [Siemens Healthcare, Forchheim (Germany); Kiessling, F [Chair of Experimental Molecular Imaging, RWTH-Aachen University, Medical Faculty, Aachen (Germany); Gupta, R [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)], E-mail: j.kuntz@dkfz.de

    2010-04-07

    A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.

  4. TraPET: High performance small animal PET with trapezoidal phoswich detector

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Hwang, Ji Yeon; Baek, Cheol-Ha; An, Su Jung; Kim, Hyun-Il; Kim, Kwang Hyun

    2011-01-01

    In recent years, small-animal PET scanners with depth of interaction (DOI) capability have been developed for molecular imaging research. The aim of this study is to perform simulations to design a high performance small-animal PET, called TraPET. TraPET has an inner diameter of 76.21 mm with 6 dual-layer phoswich detector modules. Each module is composed of a 5.0-mm-thick trapezoidal-monolithic-LSO crystal with a front face (surface facing toward the inside of the scanner) of 44.0x44.0 mm 2 and a back face of 50.0x50.0 mm 2 and a 25x25 array of LuYAP crystals with a 2.0x2.0 mm 2 sensitive area with a 15.0 mm thickness. DOI information is extracted by a pulse shape discrimination method. The ability of event positioning in the trapezoidal-monolithic-LSO was evaluated by modeling the light distribution in the crystal using DETECT2000 and a 16x16 array of silicon photo-multipliers (SiPMs), with a 3.0 mm pixel size, selected as the photo-sensor. Also, the sensitivity and gap filling effect between modules were simulated using the Monte Carlo code, GATE. The new detector showed higher and more uniform sensitivity, as compared to scanners with rectangular-shaped detectors, because the trapezoidal-monolithic-LSO minimizes the dead space within the detector ring. In conclusion, our new detector proved to be a reliable design for small-animal PET with high spatial resolution by DOI information, and high sensitivity by high filling fraction.

  5. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  6. Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal Imaging

    Directory of Open Access Journals (Sweden)

    Susanne Greschus

    2005-08-01

    Full Text Available Noninvasive radiologic imaging has recently gained considerable interest in basic, preclinical research for monitoring disease progression, therapeutic efficacy. In this report, we introduce flat-panel volumetric computed tomography (fpVCT as a powerful new tool for noninvasive imaging of different organ systems in preclinical research. The three-dimensional visualization that is achieved by isotropic high-resolution datasets is illustrated for the skeleton, chest, abdominal organs, brain of mice. The high image quality of chest scans enables the visualization of small lung nodules in an orthotopic lung cancer model, the reliable imaging of therapy side effects such as lung fibrosis. Using contrast-enhanced scans, fpVCT displayed the vascular trees of the brain, liver, kidney down to the subsegmental level. Functional application of fpVCT in dynamic contrast-enhanced scans of the rat brain delivered physiologically reliable data of perfusion, tissue blood volume. Beyond scanning of small animal models as demonstrated here, fpVCT provides the ability to image animals up to the size of primates.

  7. Small Animal Models for Human Metapneumovirus: Cotton Rat is More Permissive than Hamster and Mouse

    Science.gov (United States)

    Zhang, Yu; Niewiesk, Stefan; Li, Jianrong

    2014-01-01

    Human metapneumovirus (hMPV) is the second most prevalent causative agent of pediatric respiratory infections worldwide. Currently, there are no vaccines or antiviral drugs against this virus. One of the major hurdles in hMPV research is the difficulty to identify a robust small animal model to accurately evaluate the efficacy and safety of vaccines and therapeutics. In this study, we compared the replication and pathogenesis of hMPV in BALB/c mice, Syrian golden hamsters, and cotton rats. It was found that BALB/c mice are not permissive for hMPV infection despite the use of a high dose (6.5 log10 PFU) of virus for intranasal inoculation. In hamsters, hMPV replicated efficiently in nasal turbinates but demonstrated only limited replication in lungs. In cotton rats, hMPV replicated efficiently in both nasal turbinate and lung when intranasally administered with three different doses (4, 5, and 6 log10 PFU) of hMPV. Lungs of cotton rats infected by hMPV developed interstitial pneumonia with mononuclear cells infiltrates and increased lumen exudation. By immunohistochemistry, viral antigens were detected at the luminal surfaces of the bronchial epithelial cells in lungs. Vaccination of cotton rats with hMPV completely protected upper and lower respiratory tract from wildtype challenge. The immunization also elicited elevated serum neutralizing antibody. Collectively, these results demonstrated that cotton rat is a robust small animal model for hMPV infection. PMID:25438015

  8. Three-dimensional segmentation and skeletonization to build an airway tree data structure for small animals

    International Nuclear Information System (INIS)

    Chaturvedi, Ashutosh; Lee, Zhenghong

    2005-01-01

    Quantitative analysis of intrathoracic airway tree geometry is important for objective evaluation of bronchial tree structure and function. Currently, there is more human data than small animal data on airway morphometry. In this study, we implemented a semi-automatic approach to quantitatively describe airway tree geometry by using high-resolution computed tomography (CT) images to build a tree data structure for small animals such as rats and mice. Silicon lung casts of the excised lungs from a canine and a mouse were used for micro-CT imaging of the airway trees. The programming language IDL was used to implement a 3D region-growing threshold algorithm for segmenting out the airway lung volume from the CT data. Subsequently, a fully-parallel 3D thinning algorithm was implemented in order to complete the skeletonization of the segmented airways. A tree data structure was then created and saved by parsing through the skeletonized volume using the Python programming language. Pertinent information such as the length of all airway segments was stored in the data structure. This approach was shown to be accurate and efficient for up to six generations for the canine lung cast and ten generations for the mouse lung cast

  9. 137Cs transmission imaging and segmented attenuation corrections in a small animal PET scanner.

    Science.gov (United States)

    Nai, Ying-Hwey; Ose, Takayuki; Shidahara, Miho; Watabe, Hiroshi

    2017-09-01

    Attenuation correction (AC) is required for accurate quantitative evaluation of small animal PET data. Our objective was to compare three AC methods in the small animal Clairvivo-PET scanner. The three AC methods involve applying attenuation coefficient maps generated by simulating a cylindrical map (SAC), segmenting the emission data (ESAC), and segmenting the transmission data (TSAC), imaged using a 137 Cs single-photon source. Investigation was carried out using a 65 mm uniform cylinder and an NEMA NU4 2008 mouse phantom, filled with water or tungsten liquid, to mimic bone. Evaluation was carried out using the difference of the segmented map volume from the known cylindrical phantom volume, the recovery of the radioactivity concentration, and the line profiles. The optimal transmission scan time for achieving accurate AC using TSAC was determined using 5, 10, 15, 20, and 25 min transmission scan time. The effects of scatter correction and reconstruction algorithms on ESAC were investigated. SAC showed the best performance but was unable to correct for different tissues and the scanner bed, and faced difficulty with correct positioning of the attenuation coefficient map. ESAC was affected by scatter correction and reconstruction algorithm, and may result in poor boundary delineation, and hence was unreliable. TSAC showed reasonable performance but required further optimization of the default segmentation setting. A minimum transmission scan time of 20 min is recommended for Clairvivo-PET using 137 Cs source to ensure that sufficient transmission counts are obtained to generate accurate attenuation coefficient map.

  10. An investigation of a coincidence detection system for an all-digital small animal PET scanner

    International Nuclear Information System (INIS)

    Liu Wei; Chen Yuanbao; Long Anwen; Chen Xin; Wu Zhongyi; Zhang Yongxue; Xie Qingguo

    2013-01-01

    Objective: To investigate and design a coincidence detection system for an all-digital small animal PET scanner and evaluate its preliminary performance properties. Methods: This coincidence module adopted a coincidence identification mode based on singles data in list-mode.Using digital signal processing technology, energy calibration, crystal identification, timing alignment and coincidence events extraction were performed on singles data in list-mode. The obtained data could be used for image reconstruction. Results: The 13 × 13 crystal array was well recognized by the position histogram of one lutetium yttrium orthosilicate (LYSO) crystal block. In the coincidence timing histogram of the micro-Derenzo phantom, 1.36 ns full width at half maximum was obtained. The rods with a diameter of 1.2 mm were clearly displayed in the reconstructed image of the micro-Derenzo phantom. Conclusion: The coincidence module can provide satisfactory performance to meet the design needs of an all-digital small animal PET scanner. (authors)

  11. Use of radiography in small animal practice in the UK and Republic of Ireland in 2013.

    Science.gov (United States)

    Booth, Naomi J; Morley, Samuel J; Ewers, Richard S

    2018-02-24

    Radiography is an essential diagnostic tool in small animal practice. A major transition is currently underway from film screen to digital systems. However, there is limited published research detailing the use of radiography in practices in the UK and Republic of Ireland (ROI). The study aimed to describe the uptake of digital radiographic systems, wider aspects of radiographic practice and use of other diagnostic imaging techniques in the UK and ROI. This is a cross-sectional study using paper and online questionnaires. Veterinary surgeons, veterinary nurses and veterinary radiographers working in small animal practice in the UK and ROI were eligible to participate in the survey. Seventy-five per cent of respondents worked in practices using digital radiography systems. Cost appeared to be the largest barrier to digital conversion. Chemical restraint was used on 86 per cent of cases; however, 3 per cent of cases were reported to be restrained by hand. Thirty-one per cent of respondents had not received specific training in radiation safety. Ultrasonography is reportedly now widely utilised on a regular basis. These results provide useful information on the use of radiography and additional diagnostic imaging techniques in the UK. These results should be used to indicate future training requirements, particularly to improve radiation safety. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Leptospirosis in a small animal veterinarian: reminder to follow standardized infection control procedures.

    Science.gov (United States)

    Baer, R; Turnberg, W; Yu, D; Wohrle, R

    2010-06-01

    A small animal veterinarian in Washington State developed leptospirosis after an occupational exposure. Approximately 10 days prior to the onset of illness, he examined a healthy appearing pet rat for fleas, which urinated on his un-gloved hands. Although the veterinarian washed his hands after the examination, his hands had abrasions from gardening. The veterinarian was hospitalized for 12 days and was able to return to work part-time 1 month following discharge. This illness may have been prevented if the veterinarian had been wearing gloves during the examination as recommended by the National Association of State Public Health Veterinarians (NASPHV), Veterinary Infection Control Committee, in its Compendium of Veterinary Standard Precautions for Zoonotic Disease Prevention in Veterinary Personnel (2008). This case alerts us to the need for small animal veterinarians to minimize their infection risk by practising recommended infection control procedures. Veterinarians should establish and follow a written infection control plan based on the standardized infection control approach adopted by the NASPHV to minimize their risk of occupational zoonotic infections.

  13. Modelling human drug abuse and addiction with dedicated small animal positron emission tomography.

    Science.gov (United States)

    Dalley, Jeffrey W; Fryer, Tim D; Aigbirhio, Franklin I; Brichard, Laurent; Richards, Hugh K; Hong, Young T; Baron, Jean-Claude; Everitt, Barry J; Robbins, Trevor W

    2009-01-01

    Drug addiction is a chronically relapsing brain disorder, which causes substantial harm to the addicted individual and society as a whole. Despite considerable research we still do not understand why some people appear particularly disposed to drug abuse and addiction, nor do we understand how frequently co-morbid brain disorders such as depression and attention-deficit hyperactivity disorder (ADHD) contribute causally to the emergence of addiction-like behaviour. In recent years positron emission tomography (PET) has come of age as a translational neuroimaging technique in the study of drug addiction, ADHD and other psychopathological states in humans. PET provides unparalleled quantitative assessment of the spatial distribution of radiolabelled molecules in the brain and because it is non-invasive permits longitudinal assessment of physiological parameters such as binding potential in the same subject over extended periods of time. However, whilst there are a burgeoning number of human PET experiments in ADHD and drug addiction there is presently a paucity of PET imaging studies in animals despite enormous advances in our understanding of the neurobiology of these disorders based on sophisticated animal models. This article highlights recent examples of successful cross-species convergence of findings from PET studies in the context of drug addiction and ADHD and identifies how small animal PET can more effectively be used to model complex psychiatric disorders involving at their core impaired behavioural self-control.

  14. Scalable electrophysiology in intact small animals with nanoscale suspended electrode arrays

    Science.gov (United States)

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Benjamin W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-07-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires invasive dissections and is low-throughput. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the first extracellular recordings of body-wall muscle electrophysiology inside an intact roundworm, Caenorhabditis elegans. We can also use nano-SPEARs to record from multiple animals in parallel and even from other species, such as Hydra littoralis. Furthermore, we use nano-SPEARs to establish the first electrophysiological phenotypes for C. elegans models for amyotrophic lateral sclerosis and Parkinson's disease, and show a partial rescue of the Parkinson's phenotype through drug treatment. These results demonstrate that nano-SPEARs provide the core technology for microchips that enable scalable, in vivo studies of neurobiology and neurological diseases.

  15. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  16. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    Science.gov (United States)

    Konik, Arda Bekir

    Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model

  17. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  18. In vivo {sup 18}F-FDG tumour uptake measurements in small animals using Cerenkov radiation

    Energy Technology Data Exchange (ETDEWEB)

    Boschi, Federico; Calderan, Laura; Fenzi, Alberto; Sbarbati, Andrea [University of Verona, Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, Verona (Italy); D' Ambrosio, Daniela; Marengo, Mario [S. Orsola - Malpighi University Hospital, Medical Physics Department, Bologna (Italy); Calandrino, Riccardo; E Spinelli, Antonello [S. Raffaele Scientific Institute, Medical Physics Department, Milan (Italy)

    2011-01-15

    2-[{sup 18}F]Fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) is a widely used PET radiotracer for the in vivo diagnosis of several diseases such as tumours. The positrons emitted by {sup 18}F-FDG, travelling into tissues faster than the speed of light in the same medium, are responsible for Cerenkov radiation (CR) emission which is prevalently in the visible range. The purpose of this study is to show that CR escaping from tumour tissues of small living animals injected with {sup 18}F-FDG can be detected with optical imaging (OI) techniques using a commercial optical instrument equipped with charge-coupled detectors (CCD). The theory behind the Cerenkov light emission and the source depth measurements using CR is first presented. Mice injected with {sup 18}F-FDG or saline solution underwent dynamic OI acquisition and a comparison between images was performed. Multispectral analysis of the radiation was used to estimate the depth of the source of Cerenkov light. Small animal PET images were also acquired in order to compare the {sup 18}F-FDG bio-distribution measured using OI and PET scanner. Cerenkov in vivo whole-body images of tumour-bearing mice and the measurements of the emission spectrum (560-660 nm range) are presented. Brain, kidneys and tumour were identified as a source of visible light in the animal body: the tissue time-activity curves reflected the physiological accumulation of {sup 18}F-FDG in these organs. The identification is confirmed by the comparison between CR and {sup 18}F-FDG images. These results will allow the use of conventional OI devices for the in vivo study of glucose metabolism in cancer and the assessment, for example, of anti-cancer drugs. Moreover, this demonstrates that {sup 18}F-FDG can be employed as it is a bimodal tracer for PET and OI techniques. (orig.)

  19. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    International Nuclear Information System (INIS)

    Lalander, Cecilia Helena; Komakech, Allan John; Vinnerås, Björn

    2015-01-01

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies

  20. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  1. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    Directory of Open Access Journals (Sweden)

    Yong-Jian Ma

    2016-01-01

    Full Text Available This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0±5.9 d rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0±4.0 d, and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0±2.9 d were statistically similar (all p>0.05 to and linearly correlated (r=0.96, p<0.01 with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0±2.7 d; RIB10, 33.0±1.3 d; and RIB20, 27.0±0.8 d. The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.

  2. Collimator optimization for small animal radiation therapy at a micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Manuela C. [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Giordano, Frank A.; Wenz, Frederik; Fleckenstein, Jens [Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Brockmann, Marc A. [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology; University Medical Center Mainz (Germany). Dept. of Neuroradiology

    2017-05-01

    In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. As expected, the shorter SSD of the W-collimators resulted in a (4.5 ± 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 ± 0.2) for the Fe- and (4.5 ± 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper

  3. Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry

    International Nuclear Information System (INIS)

    Angelis, G I; Kyme, A Z; Ryder, W J; Fulton, R R; Meikle, S R

    2014-01-01

    Attenuation correction in positron emission tomography brain imaging of freely moving animals is a very challenging problem since the torso of the animal is often within the field of view and introduces a non negligible attenuating factor that can degrade the quantitative accuracy of the reconstructed images. In the context of unrestrained small animal imaging, estimation of the attenuation correction factors without the need for a transmission scan is highly desirable. An attractive approach that avoids the need for a transmission scan involves the generation of the hull of the animal’s head based on the reconstructed motion corrected emission images. However, this approach ignores the attenuation introduced by the animal’s torso. In this work, we propose a virtual scanner geometry which moves in synchrony with the animal’s head and discriminates between those events that traversed only the animal’s head (and therefore can be accurately compensated for attenuation) and those that might have also traversed the animal’s torso. For each recorded pose of the animal’s head a new virtual scanner geometry is defined and therefore a new system matrix must be calculated leading to a time-varying system matrix. This new approach was evaluated on phantom data acquired on the microPET Focus 220 scanner using a custom-made phantom and step-wise motion. Results showed that when the animal’s torso is within the FOV and not appropriately accounted for during attenuation correction it can lead to bias of up to 10% . Attenuation correction was more accurate when the virtual scanner was employed leading to improved quantitative estimates (bias < 2%), without the need to account for the attenuation introduced by the extraneous compartment. Although the proposed method requires increased computational resources, it can provide a reliable approach towards quantitatively accurate attenuation correction for freely moving animal studies. (paper)

  4. A high resolution small animal radiation research platform (SARRP) with x-ray tomographic guidance capabilities

    Science.gov (United States)

    Wong, John; Armour, Elwood; Kazanzides, Peter; Iordachita, Iulian; Tryggestad, Erik; Deng, Hua; Matinfar, Mohammad; Kennedy, Christopher; Liu, Zejian; Chan, Timothy; Gray, Owen; Verhaegen, Frank; McNutt, Todd; Ford, Eric; DeWeese, Theodore L.

    2008-01-01

    Purpose To demonstrate the CT imaging, conformal irradiation and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods The SARRP employs a dual-focal spot, constant voltage x-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120° from vertical. Eighty to 100 kVp x-rays from the smaller 0.4 mm focal spot are used for imaging. Both 0.4 mm and 3.0 mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam (CB) CT imaging is achieved by rotating the horizontal animal between the stationary x-ray source and a flat-panel detector. Radiation beams range from 0.5 mm in diameter to (60 × 60) mm2. Dosimetry is measured with radio-chromic films. Monte Carlo dose calculations are employed for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results The SARRP spans 3 ft × 4 ft × 6 ft (WxLxH). Depending on filtration, the isocenter dose outputs at 1 cm depth in water range from 22 to 375 cGy/min from the smallest to the largest radiation fields. The 20% to 80% dose fall-off spans 0.16 mm. CBCT with (0.6 × 0.6 × 0.6) mm3 voxel resolution is acquired with less than 1 cGy. Treatment planning is performed at sub-mm resolution. Conclusions The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. PMID:18640502

  5. An x-ray image guidance system for small animal stereotactic irradiation

    Science.gov (United States)

    Song, K. H.; Pidikiti, R.; Stojadinovic, S.; Speiser, M.; Seliounine, S.; Saha, D.; Solberg, T. D.

    2010-12-01

    An x-ray image-guided small animal stereotactic irradiator was developed and characterized to enable tumor visualization and accurate target localization for small field, high dose irradiation. The system utilizes a custom collimation system, a motorized positioning system (x, y, θ), a digital imaging panel and operating software, and is integrated with a commercial x-ray unit. The essential characteristics of the irradiator include small radiation fields (1-10 mm), high dose rate (>10 Gy min-1) and submillimeter target localization. The software enables computer-controlled image acquisition, stage motion and target localization providing simple and precise automated target localization. The imaging panel was characterized in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and spatial resolution. Overall localization accuracy and precision were assessed. SNR, CNR and spatial resolution are 24 dB, 21 dB and 2.8 lp mm-1, respectively, and localization accuracy is approximately 65 µm with 6 µm precision. With the aid of image guidance, system performance was subsequently used to evaluate radiation response in a rat orthotopic lung tumor effectively sparing normal tissues and in a mouse normal lung. The capabilities of 3D treatment and cone-beam computed tomography are presented for 3D localization and delivery as a work in progress.

  6. Summary of the World Small Animal Veterinary Association standardization committee guide to classification of liver disease in dogs and cats.

    Science.gov (United States)

    Cullen, John M

    2009-05-01

    Liver disease is a frequently encountered problem in small animal practice. The World Small Animal Veterinary Association has formed a group of experienced clinicians and pathologists to develop a standardized format for diagnostic terminology. This is hoped to lead to greater uniformity in diagnoses and better communication between clinicians and pathologists alike. The aim is to find a sound scientific basis of diagnostic and treatment protocols for hepatobiliary diseases. This article provides an overview of that monograph.

  7. Biological effects of high-strength electric fields on small laboratory animals. Interim report, March 1, 1978-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, R.D.; Anderson, L.E.; Kaune, W.T.

    1979-12-01

    Progress is described on a project assessing the biological effects of 60-Hz electric fields on small laboratory animals (rats and mice). The report includes sections on hematology and seram chemistry, immunology, pathology, metabolism, bone growth, endocrinology, cardiovascular function, neurophysiology, growth and development, and animal behavior. (ACR)

  8. Performing Repeated Quantitative Small-Animal PET with an Arterial Input Function Is Routinely Feasible in Rats.

    Science.gov (United States)

    Huang, Chi-Cheng; Wu, Chun-Hu; Huang, Ya-Yao; Tzen, Kai-Yuan; Chen, Szu-Fu; Tsai, Miao-Ling; Wu, Hsiao-Ming

    2017-04-01

    Performing quantitative small-animal PET with an arterial input function has been considered technically challenging. Here, we introduce a catheterization procedure that keeps a rat physiologically stable for 1.5 mo. We demonstrated the feasibility of quantitative small-animal 18 F-FDG PET in rats by performing it repeatedly to monitor the time course of variations in the cerebral metabolic rate of glucose (CMR glc ). Methods: Aseptic surgery was performed on 2 rats. Each rat underwent catheterization of the right femoral artery and left femoral vein. The catheters were sealed with microinjection ports and then implanted subcutaneously. Over the next 3 wk, each rat underwent 18 F-FDG quantitative small-animal PET 6 times. The CMR glc of each brain region was calculated using a 3-compartment model and an operational equation that included a k* 4 Results: On 6 mornings, we completed 12 18 F-FDG quantitative small-animal PET studies on 2 rats. The rats grew steadily before and after the 6 quantitative small-animal PET studies. The CMR glc of the conscious brain (e.g., right parietal region, 99.6 ± 10.2 μmol/100 g/min; n = 6) was comparable to that for 14 C-deoxyglucose autoradiographic methods. Conclusion: Maintaining good blood patency in catheterized rats is not difficult. Longitudinal quantitative small-animal PET imaging with an arterial input function can be performed routinely. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  9. Development of visible and NIR imaging equipment for small animals with smart pad.

    Science.gov (United States)

    Eum, Nyeon Sik; Han, Jung Hyun; Seong, Ki Woong; Lee, Jong Ha; Park, Hee Joon

    2014-01-01

    The portable visible and near-infrared (NIR) imaging equipment for a pre-clinical test with small animals was designed and developed in this paper. The developed equipment is composed of a CCD camera, a focusing lens, an objective lens, a NIR band pass filter and a NIR filter driving motor. An NIR ray is mainly used for imaging equipment because it has high light penetration depth in biological tissue. Therefore, NIR fluorescent agents are available for chemical conjugation to targeting molecules in vivo. This equipment can provide a visible image, NIR image and merged image simultaneously. A communication system was specifically established to check obtained images through a smart pad in real time. It is less dependent on space and time than the conventional system.

  10. RNA interference against animal viruses: how morbilliviruses generate extended diversity to escape small interfering RNA control.

    Science.gov (United States)

    Holz, Carine L; Albina, Emmanuel; Minet, Cécile; Lancelot, Renaud; Kwiatek, Olivier; Libeau, Geneviève; Servan de Almeida, Renata

    2012-01-01

    Viruses are serious threats to human and animal health. Vaccines can prevent viral diseases, but few antiviral treatments are available to control evolving infections. Among new antiviral therapies, RNA interference (RNAi) has been the focus of intensive research. However, along with the development of efficient RNAi-based therapeutics comes the risk of emergence of resistant viruses. In this study, we challenged the in vitro propensity of a morbillivirus (peste des petits ruminants virus), a stable RNA virus, to escape the inhibition conferred by single or multiple small interfering RNAs (siRNAs) against conserved regions of the N gene. Except with the combination of three different siRNAs, the virus systematically escaped RNAi after 3 to 20 consecutive passages. The genetic modifications involved consisted of single or multiple point nucleotide mutations and a deletion of a stretch of six nucleotides, illustrating that this virus has an unusual genomic malleability.

  11. Scatter characterization and correction for simultaneous multiple small-animal PET imaging.

    Science.gov (United States)

    Prasad, Rameshwar; Zaidi, Habib

    2014-04-01

    The rapid growth and usage of small-animal positron emission tomography (PET) in molecular imaging research has led to increased demand on PET scanner's time. One potential solution to increase throughput is to scan multiple rodents simultaneously. However, this is achieved at the expense of deterioration of image quality and loss of quantitative accuracy owing to enhanced effects of photon attenuation and Compton scattering. The purpose of this work is, first, to characterize the magnitude and spatial distribution of the scatter component in small-animal PET imaging when scanning single and multiple rodents simultaneously and, second, to assess the relevance and evaluate the performance of scatter correction under similar conditions. The LabPET™-8 scanner was modelled as realistically as possible using Geant4 Application for Tomographic Emission Monte Carlo simulation platform. Monte Carlo simulations allow the separation of unscattered and scattered coincidences and as such enable detailed assessment of the scatter component and its origin. Simple shape-based and more realistic voxel-based phantoms were used to simulate single and multiple PET imaging studies. The modelled scatter component using the single-scatter simulation technique was compared to Monte Carlo simulation results. PET images were also corrected for attenuation and the combined effect of attenuation and scatter on single and multiple small-animal PET imaging evaluated in terms of image quality and quantitative accuracy. A good agreement was observed between calculated and Monte Carlo simulated scatter profiles for single- and multiple-subject imaging. In the LabPET™-8 scanner, the detector covering material (kovar) contributed the maximum amount of scatter events while the scatter contribution due to lead shielding is negligible. The out-of field-of-view (FOV) scatter fraction (SF) is 1.70, 0.76, and 0.11% for lower energy thresholds of 250, 350, and 400 keV, respectively. The increase in SF

  12. Contribution of customised dosimetry for small animal to the treatments of cancers by metabolic radiotherapy

    International Nuclear Information System (INIS)

    Boutaleb, Samir

    2010-01-01

    This research thesis first reports a bibliographical study which addressed the use of ionizing radiations in cancer therapy (evolution from ionizing radiation to metabolic radiotherapy, biological and physical parameters, and absorbed dose in metabolic radiotherapy) and the role imagery has in customised dosimetry (absorbed dose calculation methods, determination of cumulative activity, dosimetric models for S factor calculation). Then, the author presents a software which has been specifically developed for the creation of dosimetric models, and reports its validation. He reports the comparison between different dosimetric models in the case of mice. He highlights two applications of the developed tool: radio-immunotherapy and metabolic radiotherapy. He finally proposes a general discussion on the impact of small animal dosimetry on metabolic radiotherapy [fr

  13. Development of Input Function Measurement System for Small Animal PET Study

    International Nuclear Information System (INIS)

    Kim, Jong Guk; Kim, Byung Su; Kim, Jin Su

    2010-01-01

    For quantitative measurement of radioactivity concentration in tissue and a validated tracer kinetic model, the high sensitive detection system has been required for blood sampling. With the accurate measurement of time activity curves (TACs) of labeled compounds in blood (plasma) enable to provide quantitative information on biological parameters of interest in local tissue. Especially, the development of new tracers for PET imaging requires knowledge of the kinetics of the tracer in the body and in arterial blood and plasma. Conventional approaches of obtaining an input function are to sample arterial blood sequentially by manual as a function of time. Several continuous blood sampling systems have been developed and used in nuclear medicine research field to overcome the limited temporal resolution in sampling by the conventional method. In this work, we developed the high sensitive and unique geometric design of GSO detector for small animal blood activity measurement

  14. First results in the application of silicon photomultiplier matrices to small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Llosa, G. [University of Pisa, Department of Physics, Pisa (Italy)], E-mail: gabriela.llosa@pi.infn.it; Belcari, N.; Bisogni, M.G. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Collazuol, G. [University of Pisa, Department of Physics, Pisa (Italy); Scuola Normale Superiore, Pisa (Italy); Marcatili, S. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N. [FBK irst, Trento (Italy); Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, Orsay (France); Del Guerra, A. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy)

    2009-10-21

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  15. First results in the application of silicon photomultiplier matrices to small animal PET

    International Nuclear Information System (INIS)

    Llosa, G.; Belcari, N.; Bisogni, M.G.; Collazuol, G.; Marcatili, S.; Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N.; Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F.; Del Guerra, A.

    2009-01-01

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  16. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    Science.gov (United States)

    Kitchen, M. J.; Habib, A.; Fouras, A.; Dubsky, S.; Lewis, R. A.; Wallace, M. J.; Hooper, S. B.

    2010-02-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  17. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kitchen, M J; Habib, A; Lewis, R A [School of Physics, Monash University, Clayton, Victoria, 3800 (Australia); Fouras, A; Dubsky, S [Division of Biological Engineering, Monash University and Fluids Laboratory for Aeronautical and Industrial Research, Monash University, Clayton, Victoria, 3800 (Australia); Wallace, M J; Hooper, S B, E-mail: Marcus.Kitchen@sci.monash.edu.a [Department of Physiology, Monash University, Clayton, Victoria 3800 (Australia)

    2010-02-15

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  18. Small animal optoacoustic tomography system for molecular imaging of contrast agents

    Science.gov (United States)

    Su, Richard; Liopo, Anton; Ermilov, Sergey A.; Oraevsky, Alexander A.

    2016-03-01

    We developed a new and improved Laser Optoacoustic Imaging System, LOIS-3D for preclinical research applications in small animal models. The advancements include (i) a new stabilized imaging module with a more homogeneous illumination of the mouse yielding a better spatial resolution (exogenous or endogenous optoacoustic contrast agents. As examples, we present in vivo experiments using phantoms and mice with and without tumor injected with contrast agents with indocyanine green (ICG). LOIS-3D was capable of detecting ~1-2 pmole of the ICG, in tissues with relatively low blood content. With its high sensitivity and excellent spatial resolution LOIS-3D is an advanced alternative to fluorescence and bioluminescence based modalities for molecular imaging in live mice.

  19. Development of locomotion after spinal cord injury in small animals – Literature review

    Directory of Open Access Journals (Sweden)

    Andréia Coutinho Facin

    2016-05-01

    Full Text Available Spinal cord injuries are common in cats and dogs and result in severe neurological deficit, which can lead to permanent loss of sensory and motor capacity. In patients with fair to poor prognoses, complementary treatments have been used to develop an involuntary and uncoordinated ambulation that resembles normal gait, commonly known as spinal locomotion or reflexive stepping. Under experimental conditions, the recovery of a rhythmic gait has been reported following complete spinal cord transection. In veterinary medicine, the development of reflex stepping is of extreme importance to the quality of life and independence of the patients, as well as the satisfaction and tranquility of the owners. The present study is a literature review about the development of locomotion after spinal cord injury in small animals.

  20. Development of locomotion after spinal cord injury in small animals – Literature review

    Directory of Open Access Journals (Sweden)

    Andréia Coutinho Facin

    2016-05-01

    Spinal cord injuries are common in cats and dogs and result in severe neurological deficit, which can lead to permanent loss of sensory and motor capacity. In patients with fair to poor prognoses, complementary treatments have been used to develop an involuntary and uncoordinated ambulation that resembles normal gait, commonly known as spinal locomotion or reflexive stepping. Under experimental conditions, the recovery of a rhythmic gait has been reported following complete spinal cord transection. In veterinary medicine, the development of reflex stepping is of extreme importance to the quality of life and independence of the patients, as well as the satisfaction and tranquility of the owners. The present study is a literature review about the development of locomotion after spinal cord injury in small animals.

  1. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  2. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  3. The Advanced Locking Plate System (ALPS): a retrospective evaluation in 71 small animal patients.

    Science.gov (United States)

    Guerrero, Tomás G; Kalchofner, Karin; Scherrer, Nicole; Kircher, Patrick

    2014-02-01

    To evaluate use of the Advanced Locking Plate System (ALPS) in dogs and cats and report outcome. Retrospective case series. Dogs (n = 29) and cats (n = 42). The medical records (April 2007-April 2010) of dogs and cats treated with ALPS were reviewed evaluated. Data retrieved included signalment, indication for surgery, complications, and outcome. ALPS was used for 54 fractures, 12 tarsal or carpal ligament injuries and in 6 cases, to prevent or treat fractures during total hip replacement. Complications needing revision surgery occurred in 4 cases (5.5%): fixation failure was identified in 3 (2 fracture-fixations, 1 pancarpal arthrodesis), and a fracture occurred through a screw hole. The most common complication after tarsal arthrodesis was suture dehiscence. All cases had healed by study end. ALPS offers a reliable alternative for fracture treatment and some other orthopedic conditions in small animals. © Copyright 2014 by The American College of Veterinary Surgeons.

  4. Design and testing of a 750 MHz CW-EPR digital console for small animal imaging

    Science.gov (United States)

    Sato-Akaba, Hideo; Emoto, Miho C.; Hirata, Hiroshi; Fujii, Hirotada G.

    2017-11-01

    This paper describes the development of a digital console for three-dimensional (3D) continuous wave electron paramagnetic resonance (CW-EPR) imaging of a small animal to improve the signal-to-noise ratio and lower the cost of the EPR imaging system. A RF generation board, an RF acquisition board and a digital signal processing (DSP) & control board were built for the digital EPR detection. Direct sampling of the reflected RF signal from a resonator (approximately 750 MHz), which contains the EPR signal, was carried out using a band-pass subsampling method. A direct automatic control system to reduce the reflection from the resonator was proposed and implemented in the digital EPR detection scheme. All DSP tasks were carried out in field programmable gate array ICs. In vivo 3D imaging of nitroxyl radicals in a mouse's head was successfully performed.

  5. STTARR: a radiation treatment and multi-modal imaging facility for fast tracking novel agent development in small animal models

    International Nuclear Information System (INIS)

    Yeung, Ivan; McKee, Trevor; Jaffray, David; Hill, Richard

    2014-01-01

    Small animal models play a pivotal role in the pipeline development of novel agents and strategies in personalized cancer therapy. The Spatio-Temporal Targeting and Amplification of Radiation Response Program (STTARR) consists of an animal imaging and precision radiation facility designed to provide innovative biologic imaging and targeted radiation treatment strategies in small animals. The design is to mirror the imaging and radiation treatment facility in a modern cancer center. The STTARR features imaging equipment of small animal scale including CT, MRI, PET, SPECT, Optical devices as well as image guided irradiators. The fleet of imaging and irradiation equipment provides a platform for identification of biological targets of the specific molecular pathways that influence both tumor progression and a patient's response to radiation therapy. Examples will be given in the utilization of the imaging facilities for development in novel approaches in cancer therapy including a PET-FAZA study for hypoxia measurement in a pancreatic adenocarcinoma xenograft model. In addition, the cone-beam image guided small animal irradiator developed at our institute will also be described. The animal platform (couch) provides motion in 3 dimensions to position the animal to the isocentre of the beam. A pair of rotational arms supporting the X-ray/detector pair enables acquisition of cone-beam images of the animal which give rise to image guided precision of 0.5 mm. The irradiation energy ranges from 50 to 225 kVp at a dose rate from 10-400 cGy/min. The gantry is able to direct X-ray beam of different directions to give conformal radiation treatment to the animal. A dedicated treatment planning system is able to perform treatment planning and provide commonly used clinical metrics in the animal treatment plan. Examples will be given to highlight the use of the image guided irradiator for research of drug/irradiation regimen in animal models. (author)

  6. Development and applications of TOHR, an original emission tomography system, adapted to small animals

    International Nuclear Information System (INIS)

    Ploux, Lydie

    1997-01-01

    For many neuro-biological studies, it is necessary to link microscopic aspects of the brain's organization with integrated brain functions. Details of the former are obtained by in vitro and in situ molecular biology techniques, whereas the latter are acquired through behavioural studies. In vivo radio-imaging methods, like emission tomography are the ideal tools to investigate the links between these two levels of brain organization. The work which is presented here focuses on a new approach of emission tomography adapted to small animal studies: TOHR (French, acronym for TOmographe Haute Resolution). The principle is based on the use of a large solid angle, high resolution and high efficiency focusing collimator. High resolution and high signal to noise ratio are improved by using nuclides having a two-photon decay with small angular correlation ( 125 I, 123 I, 111 In,...). The image is built step-by-step, by moving the animal relative to the collimator focal point. First, numerical simulation showed the possibility of reaching sub-millimetric resolutions; these results led to the collimator geometry (at present 10 over the 20 faces of an icosahedron, 15 faces in the future). Then, a prototype of TOHR has been built and characterized. Its performance is very close to the numerical prediction: spatial resolution of 1.4 mm and detection efficiency 0.64%. Finally, experiments on a rat thyroid allowed the preparation and realization of the first experiments on a rat striatum. The good quality of these images shows that it is now possible to evaluate TOHR capabilities on a dopaminergic neuron degeneration model in rats in the field of neuro-degenerative disease studies. (author)

  7. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J.; Galvis-Alonso, O.Y., E-mail: mejia_famerp@yahoo.com.b [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Biologia Molecular; Castro, A.A. de; Simoes, M.V. [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Clinica Medica; Leite, J.P. [Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Dept. de Neurociencias e Ciencias do Comportamento; Braga, J. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil). Div. de Astrofisica

    2010-11-15

    The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target's three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology. (author)

  8. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  9. SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Jermoumi, M; Ngwa, W [University of Massachusetts Lowell, MA (United States); Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Korideck, H; Zygmanski, P; Berbeco, R; Makrigiorgos, G; Cormack, R [Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States)

    2014-06-01

    Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests.

  10. Small animal SPECT and its place in the matrix of molecular imaging technologies

    International Nuclear Information System (INIS)

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-01-01

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute ( -10 molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies. (topical review)

  11. Effect of National Football League games on small animal emergency room caseload.

    Science.gov (United States)

    Rozanski, Elizabeth A; Rondeau, Mark P; Shaw, Scott P; Rush, John E

    2009-07-01

    To evaluate whether games of popular professional football teams have an effect on small animal emergency room caseload and percentage of dogs and cats that subsequently are hospitalized, are euthanatized, or die following admission to veterinary emergency rooms located within a dedicated fan base. Prospective study. 818 dogs and cats admitted to the emergency room. During the 2007 New England Patriots (NEP) football season, small animal emergency room caseload was recorded for Sunday (4-hour blocks, 8:00 AM until 12:00 midnight) and Monday night (7:00 PM to 11:00 PM). Number of dogs and cats that subsequently were hospitalized, died, or were euthanatized was recorded. Mean game importance rating (GIR) was determined for NEP games (scale, 1 [mild] to 3 [great]). Percentage of dogs and cats admitted from 12:00 noon to 4:00 PM on Sundays during NEP games (mean GIR, 1.7) versus non-NEP games was not different. Mean +/- SD percentage of dogs and cats admitted from 4:00 PM to 8:00 PM on Sundays during NEP games (mean GIR, 2.4) versus non-NEP games was significantly different (18 +/- 5% and 25 +/- 7% of daily caseload, respectively). Percentage of dogs and cats admitted from 8:00 PM to 12:00 midnight on Sundays during NEP games (mean GIR, 2.1) versus non-NEP games was not different. Game type (NEP vs non-NEP) during emergency room admission did not influence whether dogs and cats subsequently were hospitalized, died, or were euthanatized. Professional sporting events may influence veterinary emergency room caseloads.

  12. Development of a Compton suppression whole body counting for small animals

    International Nuclear Information System (INIS)

    Martini, Elaine

    1995-01-01

    The basic operation, design and construction of the plastic scintillator detector is described. In order to increase the sensitivity of this detector, two blocks of plastic scintillator have been assembled to act as a anticompton system. The detectors were produced by polymerisation of styrene monomer with PPO (2,5 diphenyl-oxazole) and POPOP (1,4 bis (-5 phenyl-2- oxazoly)benzene) in proportions of 0.5 and 0.05 respectively. The transparency of this detector was evaluated by excitation of the 241 Am source located directly in the back surface plastic coupled to a photomultiplier. The light attenuation according to the detector thickness has fitted to a two-exponential function: relative height pulse = 0,519 e -0.0016 + 0.481 e -0.02112.x . Four radioactive sources 2 2 Na, 54 Mn, 137 Cs and 131 I were used to evaluate the performance of this system. The Compton reduction factor, determined by the ratio of the energy peak values of suppressed and unsuppressed spectra was 1.16. The Compton suppression factor determined by the ratio of the net photopeak area to the area of an equal spectra width in the Compton continuum, was approximately 1.208 ± 0.109. The sensitivity of the system, defined as the least amount of a radioactivity that can be quantified in the photopeak region, was 9.44 cps. First, the detector was assembled to be applied in biological studies of whole body counter measurements of small animals. Using a phantom, (small animal simulator) and a punctual 137 Cs source, located in the central region of the well counter the geometrical efficiency detector was about 5%. (author)

  13. Assessment of a New High-Performance Small-Animal X-Ray Tomograph

    Science.gov (United States)

    Vaquero, J. J.; Redondo, S.; Lage, E.; Abella, M.; Sisniega, A.; Tapias, G.; Montenegro, M. L. Soto; Desco, M.

    2008-06-01

    We have developed a new X-ray cone-beam tomograph for in vivo small-animal imaging using a flat panel detector (CMOS technology with a microcolumnar CsI scintillator plate) and a microfocus X-ray source. The geometrical configuration was designed to achieve a spatial resolution of about 12 lpmm with a field of view appropriate for laboratory rodents. In order to achieve high performance with regard to per-animal screening time and cost, the acquisition software takes advantage of the highest frame rate of the detector and performs on-the-fly corrections on the detector raw data. These corrections include geometrical misalignments, sensor non-uniformities, and defective elements. The resulting image is then converted to attenuation values. We measured detector modulation transfer function (MTF), detector stability, system resolution, quality of the reconstructed tomographic images and radiated dose. The system resolution was measured following the standard test method ASTM E 1695 -95. For image quality evaluation, we assessed signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as a function of the radiated dose. Dose studies for different imaging protocols were performed by introducing TLD dosimeters in representative organs of euthanized laboratory rats. Noise figure, measured as standard deviation, was 50 HU for a dose of 10 cGy. Effective dose with standard research protocols is below 200 mGy, confirming that the system is appropriate for in vivo imaging. Maximum spatial resolution achieved was better than 50 micron. Our experimental results obtained with image quality phantoms as well as with in-vivo studies show that the proposed configuration based on a CMOS flat panel detector and a small micro-focus X-ray tube leads to a compact design that provides good image quality and low radiated dose, and it could be used as an add-on for existing PET or SPECT scanners.

  14. Dosimetric characterization of an image-guided stereotactic small animal irradiator

    Science.gov (United States)

    Pidikiti, R.; Stojadinovic, S.; Speiser, M.; Song, K. H.; Hager, F.; Saha, D.; Solberg, T. D.

    2011-04-01

    Small animal irradiation provides an important tool used by preclinical studies to assess and optimize new treatment strategies such as stereotactic ablative radiotherapy. Characterization of radiation beams that are clinically and geometrically scaled for the small animal model is uniquely challenging for orthovoltage energies and minute field sizes. The irradiator employs a commercial x-ray device (XRAD 320, Precision x-ray, Inc.) with a custom collimation system to produce 1-10 mm diameter beams and a 50 mm reference beam. Absolute calibrations were performed using the AAPM TG-61 methodology. Beam's half-value layer (HVL) and timer error were measured with an ionization chamber. Percent depth dose (PDD), output factors (OFs) and off-axis ratios were measured using radiochromic film, a diode and a pinpoint ionization chamber at 19.76 and 24.76 cm source-to-surface distance (SSD). PDD measurements were also compared with Monte Carlo (MC) simulations. In-air and in-water absolute calibrations for the reference 50 mm diameter collimator at 19.76 cm SSD were measured as 20.96 and 20.79 Gy min-1, respectively, agreeing within 0.8%. The HVL at 250 kVp and 15 mAs was measured to be 0.45 mm Cu. The reference field PDD MC simulation results agree with measured data within 3.5%. PDD data demonstrate typical increased penetration with increasing field size and SSD. For collimators larger than 5 mm in diameter, OFs measured using film, an ion chamber and a diode were within 3% agreement.

  15. New experimental model for single liver lobe hyperthermia in small animals using non-directional microwaves.

    Directory of Open Access Journals (Sweden)

    Ionuț Tudorancea

    Full Text Available Our aim was to develop a new experimental model for in vivo hyperthermia using non-directional microwaves, applicable to small experimental animals. We present an affordable approach for targeted microwave heat delivery to an isolated liver lobe in rat, which allows rapid, precise and stable tissue temperature control.A new experimental model is proposed. We used a commercial available magnetron generating 2450 MHz, with 4.4V and 14A in the filament and 4500V anodic voltage. Modifications were required in order to adjust tissue heating such as to prevent overheating and to allow for fine adjustments according to real-time target temperature. The heating is controlled using a virtual instrument application implemented in LabView® and responds to 0.1° C variations in the target. Ten healthy adult male Wistar rats, weighing 250-270 g were used in this study. The middle liver lobe was the target for controlled heating, while the rest of the living animal was protected.In vivo microwave delivery using our experimental setting is safe for the animals. Target tissue temperature rises from 30°C to 40°C with 3.375°C / second (R2 = 0.9551, while the increment is lower it the next two intervals (40-42°C and 42-44°C with 0.291°C/ s (R2 = 0.9337 and 0.136°C/ s (R2 = 0.7894 respectively, when testing in sequences. After reaching the desired temperature, controlled microwave delivery insures a very stable temperature during the experiments.We have developed an inexpensive and easy to manufacture system for targeted hyperthermia using non-directional microwave radiation. This system allows for fine and stable temperature adjustments within the target tissue and is ideal for experimental models testing below or above threshold hyperthermia.

  16. Imaging circulating tumor cells in freely moving awake small animals using a miniaturized intravital microscope.

    Directory of Open Access Journals (Sweden)

    Laura Sarah Sasportas

    Full Text Available Metastasis, the cause for 90% of cancer mortality, is a complex and poorly understood process involving the invasion of circulating tumor cells (CTCs into blood vessels. These cells have potential prognostic value as biomarkers for early metastatic risk. But their rarity and the lack of specificity and sensitivity in measuring them render their interrogation by current techniques very challenging. How and when these cells are circulating in the blood, on their way to potentially give rise to metastasis, is a question that remains largely unanswered. In order to provide an insight into this "black box" using non-invasive imaging, we developed a novel miniature intravital microscopy (mIVM strategy capable of real-time long-term monitoring of CTCs in awake small animals. We established an experimental 4T1-GL mouse model of metastatic breast cancer, in which tumor cells express both fluorescent and bioluminescent reporter genes to enable both single cell and whole body tumor imaging. Using mIVM, we monitored blood vessels of different diameters in awake mice in an experimental model of metastasis. Using an in-house software algorithm we developed, we demonstrated in vivo CTC enumeration and computation of CTC trajectory and speed. These data represent the first reported use we know of for a miniature mountable intravital microscopy setup for in vivo imaging of CTCs in awake animals.

  17. "Clean, green and ethical" animal production. Case study: reproductive efficiency in small ruminants.

    Science.gov (United States)

    Martin, Graeme B; Kadokawa, Hiroya

    2006-02-01

    In response to changes in society and thus the marketplace, we need a vision for the future of our animal industries, including both on-farm and off-farm activities, that is "clean, green and ethical". Using small ruminants as a case study, we describe three "clean, green and ethical" strategies that farmers could use to improve reproductive performance. The first allows control of the timing of reproductive events by using socio-sexual signals (the "male effect") to induce synchronised ovulation in females. The second strategy, "focus feeding", is based on using short periods of nutritional supplements that are precisely timed and specifically designed for each event in the reproductive process (eg, gamete production, embryo survival, fetal programming, colostrum production). The third strategy aims to maximize offspring survival by a combination of management, nutrition and genetic selection for behaviour (temperament). All of these approaches involve non-pharmacological manipulation of the endogenous control systems of the animals and complement the detailed information from ultrasound that is now becoming available. Importantly, these approaches all have a solid foundation in reproductive biology. In several cases, they are currently used in commercial practice, but there is still room for improvement through both basic and applied research. Ultimately, these "clean, green and ethical" tools can be cost-effective, increase productivity and, at the same time, greatly improve the image of meat and milk industries in society and the marketplace.

  18. A novel aerosol generator for homogenous distribution of powder over the lungs after pulmonary administration to small laboratory animals

    NARCIS (Netherlands)

    Tonnis, Wouter F.; Bagerman, Marieke; Weij, Michel; Sjollema, Jelmer; Frijlink, Henderik W.; Hinrichs, Wouter L. J.; de Boer, Anne H.

    2014-01-01

    To evaluate powder formulations for pulmonary administration in pre-clinic research, the powder should be administered to the lungs of small laboratory animals. To do so properly, a device is needed that generates particles small enough to reach deep into the lungs. In this study a newly developed

  19. Depth of interaction (DOI) determination in three-layer small animal PET

    International Nuclear Information System (INIS)

    Kwon, Sun II; Hong, Seong Jong; Ito, Mikiko; Lee, Geon Song; Sim, Kwang Souk; Park, Kwang Suk; Rhee, June Tak; Lee, Jae Sung

    2007-01-01

    Improved spatial resolution without sacrificing sensitivity is one of the most challenging developmental goals for small animal PET scanners. The 3-layer configuration that we propose here utilizes relative offsets of half a crystal pitch in x, y directions, and pulse shape discrimination to obtain DOI. We present recent progress in developing the 3-layer PET scanner with LGSO crystals and H9500 PMTs. 3-layers of crystals (of each crystal 1.5x1.5x7.0 mm 3 ) were composed of a L 0.2 GSO crystal layer and a L 0.9 GSO crystal layer aligned with each other, and a L 0.9 GSO crystal layer offset at half a crystal pitch in x, y directions. The L 0.2 GSO crystal layer was attached to a Hamamatsu H9500. The devised small animal PET scanner has a diameter of 84 mm. We built a charge division circuit consisted of resistor matrix. Struck positions by photons were obtained with the 4 signals from the circuit. To study the layer identification capability of two crystal layers with a relative offset by half a crystal, we assembled two crystal layers with a 7x7 L 0.9 GSO crystal block and a 6x6 L 0.9 GSO crystal and obtained flood images at the center and the corner of the H9500 PMT. The crystal identification between the aligned L 0.2 GSO and L 0.9 GSO crystal layers was obtained using different pulse characteristics from these two crystals. The flood image of the 2-layer crystal blocks at the center and the corner of the H9500 PMT shows the clear separation of individual crystals and no distortion of image. The ratios of peaks to valleys of horizontal and vertical projection diagrams were about 5 ∼ 6(center) and 3 ∼ 4(corner). Energy resolutions were 14.4% (6x6 crystals) and 18.1% (7x7 crystals). We also achieved the crystal identification efficiencies of ∼99%. Based on these results, we are confident that a 3-layer animal PET scanner with high resolution and sensitivity can be built

  20. Multi-modality image reconstruction for dual-head small-animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chang-Han; Chou, Cheng-Ying [National Taiwan University, Taipei, Taiwan (China)

    2015-05-18

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  1. Experimental Characterization of Monolithic-Crystal Small Animal PET Detectors Read Out by APD Arrays

    Science.gov (United States)

    Maas, M. C.; van der Laan, D. J.; Schaart, D. R.; Huizenga, J.; Brouwer, J. C.; Bruyndonckx, P.; Leonard, S.; Lemaitre, C.; van Eijk, C. W. E.

    2006-06-01

    Minimizing dead space is one way to increase the detection efficiency of small-animal PET scanners. By using monolithic scintillator crystals (e.g., 20 mm/spl times/10 mm/spl times/10 mm LSO), loss of efficiency due to inter-crystal reflective material is minimized. Readout of such crystals can be performed by means of one or more avalanche photo-diode (APD) arrays optically coupled to the crystal. The entry point of a gamma photon on the crystal surface can be estimated from the measured distribution of the scintillation light over the APD array(s). By estimating the entry point, correction for the depth-of-interaction (DOI) is automatically provided. We are studying the feasibility of such detector modules. To this end, a 64-channel test setup has been developed. Experiments to determine the effect on the spatial resolution of crystal surface finish and detector geometry have been carried out. The first results of these experiments are presented and compared to simulation results. The crystal surface finish has only a small influence on the spatial resolution. The spatial resolution of 20 mm/spl times/10 mm/spl times/10 mm detectors is significantly better when read out on the front side than when read out on the back side. With a 20 mm/spl times/10 mm/spl times/20 mm crystal coupled to two APD arrays, a very small resolution degradation of only /spl sim/0.2 mm is observed for an incidence angle of 30/spl deg/ compared to normal incidence.

  2. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    Science.gov (United States)

    Qian, Ming; Niu, Lili; Wang, Yanping; Jiang, Bo; Jin, Qiaofeng; Jiang, Chunxiang; Zheng, Hairong

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  3. Microbiological Standardization in Small Laboratory Animals and Recommendations for the Monitoring

    OpenAIRE

    Meral Karaman

    2014-01-01

    Microbiological standardization in laboratory animal breeding is based on the classification according to the microorganisms that the animals host and consequently their upbringing environment, as well as the certification of their microbiological status and the protection of their properties. Although there are many different classifications for microbiological standardization of laboratory animals, they can be basically classified as; gnotobiotic animals, animals bred with a complete barrie...

  4. PKU-PET-II: A novel SiPM-based PET imaging system for small animals

    Science.gov (United States)

    Xie, Zhaoheng; Li, Suying; Zhou, Kun; Vuletic, Ivan; Meng, Xiangxi; Zhu, Sihao; Xu, Huan; Yang, Kun; Xu, Baixuan; Zhang, Jinming; Ren, Qiushi

    2018-01-01

    The objective of this study was to introduce, describe, and validate the performance of a novel preclinical silicon photomultiplier (SiPM)-based PET system (PKU-PET-II). Briefly, the detector assembly consisted of cerium-doped lutetium-yttrium oxyorthosilicate (LYSO) crystals, with dimensions of 2 ×2 ×15 mm3, that offered a 60 mm transaxial field of view (FOV) and 32 mm axial FOV, respectively. The compact front-end electronics readout and digital controller implemented architecture in the FPGA were noteworthy improvements in PKU-PET-II over its predecessor (PKU-PET-I). Based on the National Electrical Manufacturers Association (NEMA) NU 04-2008 standards, the design of the PKU-PET-II system was validated by a phantom experiment. The results presented spatial resolution (evaluated as full width at half maximum) with a system range from 1.68 ±0.07 to 2.31 ±0.03 mm at the FOV center and from 1.43 ±0.02 to 2.10 ±0.10 mm at the 1/4th axial FOV, respectively. The system's absolute sensitivity at the center position was 1.35% with the coincidence window of 6 ns and energy window of 300-700 keV. In addition, the NEMA image quality phantom and an animal study results validated the system imaging performance in preclinical imaging application. In conclusion, this SiPM-based, small-animal PET system (PKU-PET-II) provided higher-resolution, adequate sensitivity, and excellent image quality and has potential as a useful tool for real-time imaging of disease progression and development in vivo.

  5. Proton radiography for inline treatment planning and positioning verification of small animals.

    Science.gov (United States)

    Müller, Johannes; Neubert, Christian; von Neubeck, Cläre; Baumann, Michael; Krause, Mechthild; Enghardt, Wolfgang; Bütof, Rebecca; Dietrich, Antje; Lühr, Armin

    2017-11-01

    As proton therapy becomes increasingly well established, there is a need for high-quality clinically relevant in vivo data to gain better insight into the radiobiological effects of proton irradiation on both healthy and tumor tissue. This requires the development of easily applicable setups that allow for efficient, fractionated, image-guided proton irradiation of small animals, the most widely used pre-clinical model. Here, a method is proposed to perform dual-energy proton radiography for inline positioning verification and treatment planning. Dual-energy proton radiography exploits the differential enhancement of object features in two successively measured two-dimensional (2D) dose distributions at two different proton energies. The two raw images show structures that are dominated by energy absorption (absorption mode) or scattering (scattering mode) of protons in the object, respectively. Data post-processing allowed for the separation of both signal contributions in the respective images. The images were evaluated regarding recognizable object details and feasibility of rigid registration to acquired planar X-ray scans. Robust, automated rigid registration of proton radiography and planar X-ray images in scattering mode could be reliably achieved with the animal bedding unit used as registration landmark. Distinguishable external and internal features of the imaged mouse included the outer body contour, the skull with substructures, the lung, abdominal structures and the hind legs. Image analysis based on the combined information of both imaging modes allowed image enhancement and calculation of 2D water-equivalent path length (WEPL) maps of the object along the beam direction. Fractionated irradiation of exposed target volumes (e.g., subcutaneous tumor model or brain) can be realized with the suggested method being used for daily positioning and range determination. Robust registration of X-ray and proton radiography images allows for the irradiation of

  6. Functionalized silica nanoparticles: a platform for fluorescence imaging at the cell and small animal levels.

    Science.gov (United States)

    Wang, Kemin; He, Xiaoxiao; Yang, XiaoHai; Shi, Hui

    2013-07-16

    Going in vivo, including living cells and the whole body, is very important for gaining a better understanding of the mystery of life and requires specialized imaging techniques. The diversity, composition, and temporal-spatial variation of life activities from cells to the whole body require the analysis techniques to be fast-response, noninvasive, highly sensitive, and stable, in situ and in real-time. Functionalized nanoparticle-based fluorescence imaging techniques have the potential to meet such needs through real-time and noninvasive visualization of biological events in vivo. Functionalized silica nanoparticles (SiNPs) doped with fluorescent dyes appear to be an ideal and flexible platform for developing fluorescence imaging techniques used in living cells and the whole body. We can select and incorporate different dyes inside the silica matrix either noncovalently or covalently. These form the functionalized hybrid SiNPs, which support multiplex labeling and ratiometric sensing in living systems. Since the silica matrix protects dyes from outside quenching and degrading factors, this enhances the photostability and biocompatibility of the SiNP-based probes. This makes them ideal for real-time and long-time tracking. One nanoparticle can encapsulate large numbers of dye molecules, which amplifies their optical signal and temporal-spatial resolution response. Integrating fluorescent dye-doped SiNPs with targeting ligands using various surface modification techniques can greatly improve selective recognition. Along with the endocytosis, functionalized SiNPs can be efficiently internalized into cells for noninvasive localization, assessment, and monitoring. These unique characteristics of functionalized SiNPs substantially support their applications in fluorescence imaging in vivo. In this Account, we summarize our efforts to develop functionalized dye-doped SiNPs for fluorescence imaging at the cell and small animal levels. We first discuss how to design and

  7. Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Choi, Yong; Cho, Gyuseong; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Byung-Tae

    2004-01-01

    A positron emission tomograph dedicated to small animal imaging should have high spatial resolution and sensitivity, and dual layer scintillators have been developed for this purpose. In this study, simulations were performed to optimize the order and the length of each crystal of a dual layer phoswich detector, and to evaluate the possibility of measuring signals from each layer of the phoswich detector. A simulation tool GATE was used to estimate the sensitivity and resolution of a small PET scanner. The proposed scanner is based on dual layer phoswich detector modules arranged in a ring of 10 cm diameter. Each module is composed of 8 x 8 arrays of phoswich detectors consisting of LSO and LuYAP with a 2 mm x 2 mm sensitive area coupled to a Hamamatsu R7600-00-M64 PSPMT. The length of the front layer of the phoswich detector varied from 0 to 10 mm at 1 mm intervals, and the total length (LSO + LuYAP) was fixed at 20 mm. The order of the crystal layers of the phoswich detector was also changed. Radial resolutions were kept below 3.4 mm and 3.7 mm over 8 cm FOV, and sensitivities were 7.4% and 8.0% for LSO 5 mm-LuYAP 15 mm, and LuYAP 6 mm-LSO 14 mm phoswich detectors, respectively. Whereas, high and uniform resolutions were achieved by using the LSO front layer, higher sensitivities were obtained by changing the crystal order. The feasibilities for applying crystal identification methods to phoswich detectors consisting of LSO and LuYAP were investigated using simulation and experimentally derived measurements of the light outputs from each layer of the phoswich detector. In this study, the optimal order and lengths of the dual layer phoswich detector were derived in order to achieve high sensitivity and high and uniform radial resolution

  8. Climbing Mount Efficiency--small steps, not giant leaps towards higher cloning success in farm animals.

    Science.gov (United States)

    Oback, Björn

    2008-07-01

    Despite more than a decade of research efforts, farm animal cloning by somatic cell nuclear transfer (SCNT) is still frustratingly inefficient. Inefficiency manifests itself at different levels, which are currently not well integrated. At the molecular level, it leads to widespread genetic, epigenetic and transcriptional aberrations in cloned embryos. At the organismal level, these genome-wide abnormalities compromise development of cloned foetuses and offspring. Specific molecular defects need to be causally linked to specific cloned phenotypes, in order to design specific treatments to correct them. Cloning efficiency depends on the ability of the nuclear donor cell to be fully reprogrammed into an embryonic state and the ability of the enucleated recipient cell to carry out the reprogramming reactions. It has been postulated that reprogrammability of the somatic donor cell epigenome is influenced by its differentiation status. However, direct comparisons between cells of divergent differentiation status within several somatic lineages have found no conclusive evidence for this. Choosing somatic stem cells as donors has not improved cloning efficiency, indicating that donor cell type may be less critical for cloning success. Different recipient cells, on the other hand, vary in their reprogramming ability. In bovine, using zygotes instead of oocytes has increased cloning success. Other improvements in livestock cloning efficiency include better coordinating donor cell type with cell cycle stage and aggregating cloned embryos. In the future, it will be important to demonstrate if these small increases at every step are cumulative, adding up to an integrated cloning protocol with greatly improved efficiency.

  9. An analog signal processing ASIC for a small animal LSO-APD PET tomograph

    International Nuclear Information System (INIS)

    Spanoudaki, V.Ch.; McElroy, D.P.; Ziegler, S.I.

    2006-01-01

    MADPET-II is a small animal PET scanner currently under development that provides individual readout for each one of its 1152 LSO-APD electronic channels. In order to process such a large number of channels individually, the analog signal processing electronics are fully integrated into monolithic chips. Each chip contains four independent differential receivers, shaping amplifiers, peak hold detectors and non-delay line constant-fraction discriminators (CFDs). The CFDs use a high-pass CR circuit rather than the conventional delay line to generate a bipolar pulse. The performance of the chip has been tested for walk, jitter and pulse height linearity by studying the peak detector and the CFD signals, and has been optimized by adjusting the corresponding bias currents so as to maximize the signal-to-noise ratio and to minimize the walk of the CFD output (trigger). The response of the peak detector to different input signal amplitudes is linear (R 2 =0.99945+/-0.00002). The walk performance of the CFD can be adjusted by changing the offset of the CR high-pass filter output signal, and can be minimized to approximately 2ns over a 5:1 input amplitude dynamic range

  10. Ultrasound Biomicroscopy in Small Animal Research: Applications in Molecular and Preclinical Imaging

    Directory of Open Access Journals (Sweden)

    A. Greco

    2012-01-01

    Full Text Available Ultrasound biomicroscopy (UBM is a noninvasive multimodality technique that allows high-resolution imaging in mice. It is affordable, widely available, and portable. When it is coupled to Doppler ultrasound with color and power Doppler, it can be used to quantify blood flow and to image microcirculation as well as the response of tumor blood supply to cancer therapy. Target contrast ultrasound combines ultrasound with novel molecular targeted contrast agent to assess biological processes at molecular level. UBM is useful to investigate the growth and differentiation of tumors as well as to detect early molecular expression of cancer-related biomarkers in vivo and to monitor the effects of cancer therapies. It can be also used to visualize the embryological development of mice in uterus or to examine their cardiovascular development. The availability of real-time imaging of mice anatomy allows performing aspiration procedures under ultrasound guidance as well as the microinjection of cells, viruses, or other agents into precise locations. This paper will describe some basic principles of high-resolution imaging equipment, and the most important applications in molecular and preclinical imaging in small animal research.

  11. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    International Nuclear Information System (INIS)

    Deng Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang Licai; Wong, John

    2007-01-01

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min -1 at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of ±5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD

  12. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    Energy Technology Data Exchange (ETDEWEB)

    Deng Hua [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Kennedy, Christopher W [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Armour, Elwood [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Jiang Licai [OSMIC Inc., 1900 Taylor Rd., Auburn Hills, MI (United States); Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States)

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min{sup -1} at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of {+-}5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  13. Development of a Si-PM-based high-resolution PET system for small animals

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Imaizumi, Masao; Watabe, Tadashi; Shimosegawa, Eku; Hatazawa, Jun; Watabe, Hiroshi; Kanai, Yasukazu

    2010-01-01

    A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 x 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: ∼45 ns; 1.1 mm x 1.2 mm x 5 mm) and 0.025 mol% Ce (decay time: ∼31 ns; 1.1 mm x 1.2 mm x 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 x 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.

  14. Development of a Si-PM-based high-resolution PET system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi [Kobe City College of Technology, Kobe (Japan); Imaizumi, Masao; Watabe, Tadashi; Shimosegawa, Eku; Hatazawa, Jun [Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Osaka (Japan); Watabe, Hiroshi; Kanai, Yasukazu, E-mail: s-yama@kobe-kosen.ac.j [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan)

    2010-10-07

    A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 x 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: {approx}45 ns; 1.1 mm x 1.2 mm x 5 mm) and 0.025 mol% Ce (decay time: {approx}31 ns; 1.1 mm x 1.2 mm x 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 x 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.

  15. FIMTrack: An open source tracking and locomotion analysis software for small animals.

    Science.gov (United States)

    Risse, Benjamin; Berh, Dimitri; Otto, Nils; Klämbt, Christian; Jiang, Xiaoyi

    2017-05-01

    Imaging and analyzing the locomotion behavior of small animals such as Drosophila larvae or C. elegans worms has become an integral subject of biological research. In the past we have introduced FIM, a novel imaging system feasible to extract high contrast images. This system in combination with the associated tracking software FIMTrack is already used by many groups all over the world. However, so far there has not been an in-depth discussion of the technical aspects. Here we elaborate on the implementation details of FIMTrack and give an in-depth explanation of the used algorithms. Among others, the software offers several tracking strategies to cover a wide range of different model organisms, locomotion types, and camera properties. Furthermore, the software facilitates stimuli-based analysis in combination with built-in manual tracking and correction functionalities. All features are integrated in an easy-to-use graphical user interface. To demonstrate the potential of FIMTrack we provide an evaluation of its accuracy using manually labeled data. The source code is available under the GNU GPLv3 at https://github.com/i-git/FIMTrack and pre-compiled binaries for Windows and Mac are available at http://fim.uni-muenster.de.

  16. Photoacoustic tomography guided diffuse optical tomography for small-animal model

    Science.gov (United States)

    Wang, Yihan; Gao, Feng; Wan, Wenbo; Zhang, Yan; Li, Jiao

    2015-03-01

    Diffuse optical tomography (DOT) is a biomedical imaging technology for noninvasive visualization of spatial variation about the optical properties of tissue, which can be applied to in vivo small-animal disease model. However, traditional DOT suffers low spatial resolution due to tissue scattering. To overcome this intrinsic shortcoming, multi-modal approaches that incorporate DOT with other imaging techniques have been intensively investigated, where a priori information provided by the other modalities is normally used to reasonably regularize the inverse problem of DOT. Nevertheless, these approaches usually consider the anatomical structure, which is different from the optical structure. Photoacoustic tomography (PAT) is an emerging imaging modality that is particularly useful for visualizing lightabsorbing structures embedded in soft tissue with higher spatial resolution compared with pure optical imaging. Thus, we present a PAT-guided DOT approach, to obtain the location a priori information of optical structure provided by PAT first, and then guide DOT to reconstruct the optical parameters quantitatively. The results of reconstruction of phantom experiments demonstrate that both quantification and spatial resolution of DOT could be highly improved by the regularization of feasible-region information provided by PAT.

  17. Radiofrequency circuit design and performance evaluation for small animal frequency-domain NIR fluorescence optical tomography

    Science.gov (United States)

    Darne, Chinmay; Zhu, Banghe; Lu, Yujie; Tan, I.-Chih; Rasmussen, John; Sevick-Muraca, Eva M.

    2011-02-01

    Herein we report on hardware development and evaluation for frequency-domain photon migration (FDPM) technique that is miniaturized for incorporation into a micro-CT gantry for hybrid CT/NIR/PET imaging. Immunity to endogenous optical properties and enhanced contrast associated with fluorophore lifetime is inherent to the FDPM measurements and enables unique opportunities for quantitative tomography when compared to the time independent (continuous wave) approach. A miniaturized radiofrequency (rf) circuitry has been developed in our laboratory for homodyne FDPM measurements that makes use of a single 100MHz oscillator to simultaneously launch optically modulated excitation light into a small animal as well as to modulate an NIR sensitive image intensifier for collection of fluorescent signals. The use of a single oscillator not only eliminates signal drift that otherwise results from the use of multiple oscillators individually driving both source and detector, but also reduces the circuit footprint for incorporation into the CT gantry. Herein, overall system performance parameters of signal-to-noise ratio, measurement precision, spatial resolution, modulation depth (ac/dc), excitation light rejection, and clinically relevant data acquisition times are presented for mouse phantom data. Image reconstruction of phantom data and integration of circuitry for hybrid CT/NIR/PET imaging is also presented towards the ultimate validation of NIR optical tomography using PET imaging as a "gold-standard" for quantification.

  18. Modern Spirometry Supports Anesthetic Management in Small Animal Clinical Practice: A Case Series.

    Science.gov (United States)

    Calice, Ivana; Moens, Yves

    2016-01-01

    Modern spirometry, like no other monitoring technique, allows insight into breath-to-breath respiratory mechanics. Spirometers continuously measure volume, airway pressure, and flow while calculating and continuously displaying respiratory system compliance and resistance in the form of loops. The aim of this case series is to show how observation of spirometric loops, similar to electrocardiogram or CO2 curve monitoring, can improve safety of anesthetic management in small animals. Spirometric monitoring cases described in this case series are based on use of the anaesthesia monitor Capnomac Ultima with a side stream spirometry sensor. The cases illustrate how recognition and understanding of spirometric loops allows for easy diagnosis of iatrogenic pneumothorax, incorrect ventilator settings, leaks in the system, kinked or partially obstructed endotracheal tube, and spontaneous breathing interfering with intermittent positive-pressure ventilation. The case series demonstrates the potential of spirometry to improve the quality and safety of anesthetic management, and, hence, its use can be recommended during intermittent positive-pressure ventilation and procedures in which interference with ventilation can be expected.

  19. Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method

    International Nuclear Information System (INIS)

    ChavarrIas, C; Vaquero, J J; Sisniega, A; RodrIguez-Ruano, A; Soto-Montenegro, M L; GarcIa-Barreno, P; Desco, M

    2008-01-01

    We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, subtraction of their average image from each individual frame produces a set of difference images. Pixels in these images have positive or negative values (according to the respiratory phase) in those areas where there is lung movement. The respiratory signals were extracted by analysing the shape of the histogram of these difference images: we calculated the first four central and non-central moments. However, only odd-order moments produced the desired breathing signal, as the even-order moments lacked information about the phase. Each of these curves was compared to a reference signal recorded by means of a pneumatic pillow. Given the similar correlation coefficients yielded by all of them, we selected the mean to implement our retrospective protocol. Respiratory phase bins were separated, reconstructed independently and included in a dynamic sequence, suitable for cine playback. We validated our method in five adult rat studies by comparing profiles drawn across the diaphragm dome, with and without retrospective respiratory gating. Results showed a sharper transition in the gated reconstruction, with an average slope improvement of 60.7%

  20. A small animal image guided irradiation system study using 3D dosimeters

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Admovics, John

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies

  1. A small animal image guided irradiation system study using 3D dosimeters

    Science.gov (United States)

    Qian, Xin; Admovics, John; Wuu, Cheng-Shie

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

  2. Evaluation of otoscope cone disinfection techniques and contamination level in small animal private practice.

    Science.gov (United States)

    Kirby, Allison L; Rosenkrantz, Wayne S; Ghubash, Rudayna M; Neradilek, Blazej; Polissar, Nayak L

    2010-04-01

    The objective of this study was to evaluate the level of bacterial contamination of otoscope cones in veterinary private practice, and to determine the most effective method of disinfection. Fifty small animal practices participated in this study, which included a detailed survey regarding otoscope cleaning, storage and usage and quantitative culture of the cleaned and stored otoscope cones. Using sterile technique, two cones from each of the 50 hospitals were swabbed and submitted for quantitative culture. Contamination was present in 29% of the samples and the following organisms were isolated: Flavobacterium brevis (10%), Pseudomonas aeruginosa (6%), Pseudomonas alcaligenes (4%), Staphylococcus intermedius (4%), Corynebacterium spp. (2%), Bacillus spp. (1%), Enterococcus faecalis (1%) Malassezia spp. (1%). There was no statistically significant difference between storage type (dry versus stored in solution) and for the instrumentation used to clean the cones (brush, cotton-tipped applicator, both versus none). There was a statistically significant difference between the different cleaning solutions (P < 0.001) and between the storage solutions (P = 0.003). A single most effective cleaning solution was unable to be determined due to the large number of solutions utilized. Cetylcide G (Cetylite Industries, Inc., Pennsauken, NJ, USA) was the most effective of the three most commonly used storage solutions (Cetylcide G, Benz-all, and 2% Chlorhexidine gluconate) when used as directed (P < 0.001). The level of contamination had a positive association with the frequency of cone use and a negative association with the frequency of storage solution replacement.

  3. Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method

    Energy Technology Data Exchange (ETDEWEB)

    ChavarrIas, C; Vaquero, J J; Sisniega, A; RodrIguez-Ruano, A; Soto-Montenegro, M L; GarcIa-Barreno, P; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Anexo PsiquiatrIa, 1 Planta. C/Ibiza, 43. Madrid 28007 (Spain)

    2008-09-07

    We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, subtraction of their average image from each individual frame produces a set of difference images. Pixels in these images have positive or negative values (according to the respiratory phase) in those areas where there is lung movement. The respiratory signals were extracted by analysing the shape of the histogram of these difference images: we calculated the first four central and non-central moments. However, only odd-order moments produced the desired breathing signal, as the even-order moments lacked information about the phase. Each of these curves was compared to a reference signal recorded by means of a pneumatic pillow. Given the similar correlation coefficients yielded by all of them, we selected the mean to implement our retrospective protocol. Respiratory phase bins were separated, reconstructed independently and included in a dynamic sequence, suitable for cine playback. We validated our method in five adult rat studies by comparing profiles drawn across the diaphragm dome, with and without retrospective respiratory gating. Results showed a sharper transition in the gated reconstruction, with an average slope improvement of 60.7%.

  4. Simulated performance of a small-animal PET scanner based on monolithic scintillation detectors

    International Nuclear Information System (INIS)

    Laan, D.J. van der; Maas, M.C.; Jong, H.W.A.M. de; Schaart, D.R.; Bruyndonckx, P.; Lemaitre, C.; Eijk, C.W.E. van

    2007-01-01

    The performance of a small-animal positron emission tomography (PET) scanner based on monolithic scintillation detectors read-out by avalanche photo-diode arrays has been investigated by simulation. By minimizing dead space, both within and between the modules, these detectors offer increased detection efficiency compared to pixellated detectors. The spatial resolution of the scanner was investigated in 2-D by simulating a point source at various radial distances from the center. To model the detector response, measured detector line-spread functions were used. An optimum value of approximately 1 mm FWHM was found at 10 mm radial distance from the scanner central axis. Point-source sensitivity profiles in the radial and axial directions were simulated at 1 MBq activity using the Monte-Carlo code GATE. They indicated that monolithic designs increase the sensitivity roughly by a factor of two compared to pixellated designs. NECR curves simulated for these scanner designs show no significant degradation of the performance for activities up to 40 MBq

  5. GATE validation of standard dual energy corrections in small animal SPECT-CT.

    Directory of Open Access Journals (Sweden)

    Sanghyeb Lee

    Full Text Available This paper addresses 123I and 125I dual isotope SPECT imaging, which can be challenging because of spectrum overlap in the low energy spectrums of these isotopes. We first quantify the contribution of low-energy photons from each isotope using GATE-based Monte Carlo simulations for the MOBY mouse phantom. We then describe and analyze a simple, but effective method that uses the ratio of detected low and high energy 123I activity to separate the mixed low energy 123I and 125I activities. Performance is compared with correction methods used in conventional tissue biodistribution techniques. The results indicate that the spectrum overlap effects can be significantly reduced, if not entirely eliminated, when attenuation and scatter is either absent or corrected for using standard methods. In particular, we show that relative activity levels of the two isotopes can be accurately estimated for a wide range of organs and provide quantitative validation that standard methods for spectrum overlap correction provide reasonable estimates for reasonable corrections in small-animal SPECT/CT imaging.

  6. Evaluation of New Inorganic Scintillators for Application in a Prototype Small Animal PET Scanner

    CERN Document Server

    Kuntner, C

    2003-01-01

    In the study of new pharmaceuticals as well as brain and genetic research, Positron Emission Tomography (PET) is a useful method. It has also recently entered the clinical domain in cardiology and particularly in oncology. Small animals such as mice, are often used to validate sophisticated models of human disease. High spatial resolution PET instrumentation is therefore necessary due to the reduced dimensions of the organs. Inorganic scintillators are employed in most of the diagnostic imaging devices. The ultimate performance of the PET scanner is tightly bound to the scintillation properties of the crystals. In the last years there has been an effort to develop new scintillating materials characterized by high light output, high detection efficiency and fast decay time. The most studied systems are mainly Ce3+-doped crystals such as LSO:Ce, YAP:Ce, LuAP:Ce, and recently also mixed Lux(RE3+)1-xAlO3:Ce crystals. These crystals are very attractive for medical application because of their high density (with th...

  7. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  8. Development of computational small animal models and their applications in preclinical imaging and therapy research

    NARCIS (Netherlands)

    Xie, Tianwu; Zaidi, Habib

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal

  9. Studying the Immunomodulatory Effects of Small Molecule Ras Inhibitors in Animal Models of Rheumatoid Arthritis

    Science.gov (United States)

    2017-10-01

    2) and in animal models of human autoimmune diseases including autoimmune colitis (3), experimental autoimmune encephalomyelitis (4), collagen...studied in multiple pre-clinical animal models of autoimmune. For example, FTS can attenuate disease manifestations in experimental autoimmune... experimental animal model of polyarthritis, which can be induced in inbred Lewis rats by immunization with Complete Freund’s adjuvant containing

  10. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Domínguez, Humberto de Jesús, E-mail: hochoa@uacj.mx [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Máynez, Leticia O. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Vergara Villegas, Osslan O. [Departamento de Ingeniería Industrial, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico)

    2015-06-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image.

  11. Fabrication of a small animal restraint for synchrotron biomedical imaging using a rapid prototyper

    International Nuclear Information System (INIS)

    Zhu Ying; Zhang Honglin; McCrea, Richard; Bewer, Brian; Wiebe, Sheldon; Nichol, Helen; Ryan, Christopher; Wysokinski, Tomasz; Chapman, Dean

    2007-01-01

    Biomedical research at synchrotron facilities may involve imaging live animals that must remain motionless for extended periods of time to obtain quality images. Even breathing movements reduce image quality but on the other hand excessive restraint of animals increases morbidity and mortality. We describe a humane animal restraint designed to eliminate head movements while promoting animal survival. This paper describes how an animal restraint that conforms to the shape of an animal's head was fabricated by a 3D prototyper. The method used to translate medical computed tomography (CT) data to a 3D stereolithography format is described and images of its use at the Canadian Light Source (CLS) are shown. This type of restraint holds great promise in improving image quality and repeatability while reducing stress on experimental animals

  12. Time over threshold readout method of SiPM based small animal PET detector

    International Nuclear Information System (INIS)

    Valastyan, I.; Gal, J.; Hegyesi, G.; Kalinka, G.; Nagy, F.; Kiraly, B.; Imrek, J.; Molnar, J.

    2012-01-01

    Complete text of publication follows. The aim of the work was to design a readout concept for silicon photomultiplier (SiPM) sensor array used in small animal PET scanner. The detector module consist of LYSO 35x35 scintillation crystals, 324 SiPM sensors (arranged in 2x2 blocks and those quads in a 9x9 configuration) and FPGA based readout electronics. The dimensions of the SiPM matrix are area: 48x48 mm 2 and the size of one SiPM sensor is 1.95x2.2 mm 2 . Due to the high dark current of the SiPM, conventional Anger based readout method does not provide sufficient crystal position maps. Digitizing the 324 SiPM channels is a straightforward way to obtain proper crystal position maps. However handling hundreds of analogue input channels and the required DSP resources cause large racks of data acquisition electronics. Therefore coding of the readout channels is required. Proposed readout method: The coding of the 324 SiPMs consists two steps: Step 1) Reduction of the channels from 324 to 36: Row column readout, SiPMs are connected to each other in column by column and row-by row, thus the required channels are 36. The dark current of 18 connected SiPMs is small in off for identifying pulses coming from scintillating events. Step 2) Reduction of the 18 rows and columns to 4 channels: Comparators were connected to each rows and columns, and the level was set above the level of dark noise. Therefore only few comparators are active when scintillation light enters in the tile. The output of the comparator rows and columns are divided to two parts using resistor chains. Then the outputs of the resistor chains are digitized by a 4 channel ADC. However instead of the Anger method, time over threshold (ToT) was used. Figure 1 shows the readout concept of the SiPM matrix. In order to validate the new method and optimize the front-end electronics of the detector, the analogue signals were digitized before the comparators using a CAEN DT5740 32 channel digitizer, then the

  13. Accurate modeling of a DOI capable small animal PET scanner using GATE

    International Nuclear Information System (INIS)

    Zagni, F.; D'Ambrosio, D.; Spinelli, AE.; Cicoria, G.; Fanti, S.; Marengo, M.

    2013-01-01

    data confirms that the developed simulation setup is a useful tool for a wide range of research applications. - Highlights: ► We developed an MC model of the Argus (Sedecal) small-animal PET scanner using GATE. ► Validation was performed through comparison between simulated and experimental data. ► Spatial resolution, sensitivity and scatter fraction showed agreement within 7%. ► NEC was in excellent agreement at activities up to 50 MBq in the field of view. ► Image quality was also compared through the NEMA NU-4 phantom

  14. Impacts of Intelligent Automated Quality Control on a Small Animal APD-Based Digital PET Scanner

    Science.gov (United States)

    Charest, Jonathan; Beaudoin, Jean-François; Bergeron, Mélanie; Cadorette, Jules; Arpin, Louis; Lecomte, Roger; Brunet, Charles-Antoine; Fontaine, Réjean

    2016-10-01

    Stable system performance is mandatory to warrant the accuracy and reliability of biological results relying on small animal positron emission tomography (PET) imaging studies. This simple requirement sets the ground for imposing routine quality control (QC) procedures to keep PET scanners at a reliable optimal performance level. However, such procedures can become burdensome to implement for scanner operators, especially taking into account the increasing number of data acquisition channels in newer generation PET scanners. In systems using pixel detectors to achieve enhanced spatial resolution and contrast-to-noise ratio (CNR), the QC workload rapidly increases to unmanageable levels due to the number of independent channels involved. An artificial intelligence based QC system, referred to as Scanner Intelligent Diagnosis for Optimal Performance (SIDOP), was proposed to help reducing the QC workload by performing automatic channel fault detection and diagnosis. SIDOP consists of four high-level modules that employ machine learning methods to perform their tasks: Parameter Extraction, Channel Fault Detection, Fault Prioritization, and Fault Diagnosis. Ultimately, SIDOP submits a prioritized faulty channel list to the operator and proposes actions to correct them. To validate that SIDOP can perform QC procedures adequately, it was deployed on a LabPET™ scanner and multiple performance metrics were extracted. After multiple corrections on sub-optimal scanner settings, a 8.5% (with a 95% confidence interval (CI) of [7.6, 9.3]) improvement in the CNR, a 17.0% (CI: [15.3, 18.7]) decrease of the uniformity percentage standard deviation, and a 6.8% gain in global sensitivity were observed. These results confirm that SIDOP can indeed be of assistance in performing QC procedures and restore performance to optimal figures.

  15. Low-dose 4D cardiac imaging in small animals using dual source micro-CT

    Science.gov (United States)

    Holbrook, M.; Clark, D. P.; Badea, C. T.

    2018-01-01

    Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome these challenges, we propose and compare improvements on two strategies for cardiac gating in dual-source, preclinical micro-CT: fast prospective gating (PG) and uncorrelated retrospective gating (RG). These sampling strategies combined with a sophisticated iterative image reconstruction algorithm provide faster acquisitions and high image quality in low-dose 4D (i.e. 3D  +  Time) cardiac micro-CT. Fast PG is performed under continuous subject rotation which results in interleaved projection angles between cardiac phases. Thus, fast PG provides a well-sampled temporal average image for use as a prior in iterative reconstruction. Uncorrelated RG incorporates random delays during sampling to prevent correlations between heart rate and sampling rate. We have performed both simulations and animal studies to validate these new sampling protocols. Sampling times for 1000 projections using fast PG and RG were 2 and 3 min, respectively, and the total dose was 170 mGy each. Reconstructions were performed using a 4D iterative reconstruction technique based on the split Bregman method. To examine undersampling robustness, subsets of 500 and 250 projections were also used for reconstruction. Both sampling strategies in conjunction with our iterative reconstruction method are capable of resolving cardiac phases and provide high image quality. In general, for equal numbers of projections, fast PG shows fewer errors than RG and is more robust to undersampling. Our results indicate that only 1000-projection based reconstruction with fast PG satisfies a 5% error criterion in left ventricular volume estimation. These methods promise low-dose imaging with a

  16. Automated analysis of small animal PET studies through deformable registration to an atlas

    International Nuclear Information System (INIS)

    Gutierrez, Daniel F.; Zaidi, Habib

    2012-01-01

    This work aims to develop a methodology for automated atlas-guided analysis of small animal positron emission tomography (PET) data through deformable registration to an anatomical mouse model. A non-rigid registration technique is used to put into correspondence relevant anatomical regions of rodent CT images from combined PET/CT studies to corresponding CT images of the Digimouse anatomical mouse model. The latter provides a pre-segmented atlas consisting of 21 anatomical regions suitable for automated quantitative analysis. Image registration is performed using a package based on the Insight Toolkit allowing the implementation of various image registration algorithms. The optimal parameters obtained for deformable registration were applied to simulated and experimental mouse PET/CT studies. The accuracy of the image registration procedure was assessed by segmenting mouse CT images into seven regions: brain, lungs, heart, kidneys, bladder, skeleton and the rest of the body. This was accomplished prior to image registration using a semi-automated algorithm. Each mouse segmentation was transformed using the parameters obtained during CT to CT image registration. The resulting segmentation was compared with the original Digimouse atlas to quantify image registration accuracy using established metrics such as the Dice coefficient and Hausdorff distance. PET images were then transformed using the same technique and automated quantitative analysis of tracer uptake performed. The Dice coefficient and Hausdorff distance show fair to excellent agreement and a mean registration mismatch distance of about 6 mm. The results demonstrate good quantification accuracy in most of the regions, especially the brain, but not in the bladder, as expected. Normalized mean activity estimates were preserved between the reference and automated quantification techniques with relative errors below 10 % in most of the organs considered. The proposed automated quantification technique is

  17. Development of a PET Insert for simultaneously small animal PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yingjie; Zhang, Zhiming; Li, Daowu; Liu, Shuangquan; Wang, Peilin; Feng, Baotong; Chai, Pei; Wei, Long [Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049 (China); Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing, 100049 (China)

    2015-05-18

    PET/MR is a new multi-modality imaging system which provide both structural and functional information with good soft tissue imaging ability and no ionizing radiation. In recent years, PET/MR is under major progress because of the development of silicon photomultipliers (SiPM). The goal of this study is to develop a MRI compatible PET insert based on SiPM and LYSO scintillator. The PET system was constituted by the detector ring, electronics and software. The detector ring consists of 16 detector module. The inner diameter of the ring was 151 mm, the external diameter was 216 mm, which was big enough for small animal research, e.g. rat, rabbit and tupaia. The sensor of each module was 2*2 SensL SPMArraySL, coupled with an array of 14 x 14 LYSO crystals, each crystal measuring 2 mm x 2 mm 10 mm. The detector was encapsulated in a copper box for light and magnetic shielding. Resister charge multiplexing circuit was used in the front end electronics. Each detector output 8X and 8Y position signals. One summed timing signal was extracted from the common cathode of all 64 channels. All these signals were transmitted to digital electronic board by a 3 m long coaxial cable from inside of the MR to the outside. Each digital electronic board handled 8 detector modules based on FPGA to obtain the timing, position and energy information of a single event. And then these single events were sent to the coincidence processing board to produce coincidence packets which are prepared for further processing. A 0.2mCi 68Ge line source was used to do the preliminary imaging test. The image was reconstructed by 3D-OSEM algorithm. The initial result proved the system to be feasible as a PET. FDG phantom imaging and simultaneous PET/MR imaging are in progress.

  18. Commentary on key aspects of fecal microbiota transplantation in small animal practice

    Directory of Open Access Journals (Sweden)

    Chaitman J

    2016-05-01

    Full Text Available Jennifer Chaitman,1 Albert E Jergens,2 Frederic Gaschen,3 Jose F Garcia-Mazcorro,4 Stanley L Marks,5 Alicia G Marroquin-Cardona,4 Keith Richter,6 Giacomo Rossi,7 Jan S Suchodolski,8 J Scott Weese9 1Veterinary Internal Medicine and Allergy Specialists, New York, NY, 2College of Veterinary Medicine, Iowa State University, Ames, IA, 3School of Veterinary Medicine, Lousiana State University, LA, USA; 4Faculty of Veterinary Medicine, Universidad Autónoma de Nuevo León, General Escobedo, Nuevo León, Mexico; 5Department of Medicine & Epidemiology, School of Veterinary Medicine, University of California, Davis, Davis, 6Veterinary Specialty Hospital of San Diego, San Diego, CA, USA; 7Department of Veterinary Science, School of Veterinary Medical Sciences, University of Camerino, Camerino, Italy; 8Gastrointestinal Laboratory, Texas A&M University, College Station, TX, USA; 9Ontario Veterinary College, University of Guelph, Guelph, ON, Canada Abstract: The gastrointestinal tract of dogs, cats, and other mammals including humans harbors millions of beneficial microorganisms that regulate and maintain health. Fecal microbiota transplantation (FMT is a procedure involving the administration of a fecal infusion from a healthy individual (donor to a patient with disease to help improve health. Despite the effectiveness of FMT to treat intestinal disorders in humans, in particular recurrent Clostridium difficile infection, there is a paucity of scientific data regarding the application of FMT in veterinary patients. Here, we outline key aspects of FMT in small animal practice. Keywords: microbiota, health, fecal microbiota transplantation, dysbiosis, enteropathogens, immune system

  19. Bioaerosol sampling for airborne bacteria in a small animal veterinary teaching hospital

    Directory of Open Access Journals (Sweden)

    Tisha A. M. Harper

    2013-08-01

    Full Text Available Background: Airborne microorganisms within the hospital environment can potentially cause infection in susceptible patients. The objectives of this study were to identify, quantify, and determine the nosocomial potential of common airborne microorganisms present within a small animal teaching hospital. Methods: Bioaerosol sampling was done initially in all 11 rooms and, subsequently, weekly samples were taken from selected rooms over a 9-week period. Samples were collected twice (morning and afternoon at each site on each sampling day. The rooms were divided into two groups: Group 1, in which morning sampling was post-cleaning and afternoon sampling was during activity, and Group 2, in which morning sampling was pre-cleaning and afternoon sampling was post-cleaning. The total aerobic bacterial plate counts per m3 and bacterial identification were done using standard microbiological methods. Results: A total of 14 bacterial genera were isolated with the most frequent being Micrococcus spp. followed by species of Corynebacterium, Bacillus, and Staphylococcus. There was a significant interaction between location and time for rooms in Group 1 (p=0.0028 but not in Group 2 (p>0.05. Microbial counts for rooms in Group 2 were significantly greater in the mornings than in the afternoon (p=0.0049. The microbial counts were also significantly different between some rooms (p=0.0333. Conclusion: The detection of significantly higher airborne microbial loads in different rooms at different times of the day suggests that the probability of acquiring nosocomial infections is higher at these times and locations.

  20. Lq -Lp optimization for multigrid fluorescence tomography of small animals using simplified spherical harmonics

    Science.gov (United States)

    Edjlali, Ehsan; Bérubé-Lauzière, Yves

    2018-01-01

    We present the first Lq -Lp optimization scheme for fluorescence tomographic imaging. This is then applied to small animal imaging. Fluorescence tomography is an ill-posed, and in full generality, a nonlinear problem that seeks to image the 3D concentration distribution of a fluorescent agent inside a biological tissue. Standard candidates for regularization to deal with the ill-posedness of the image reconstruction problem include L1 and L2 regularization. In this work, a general Lq -Lp regularization framework (Lq discrepancy function - Lp regularization term) is introduced for fluorescence tomographic imaging. A method to calculate the gradient for this general framework is developed which allows evaluating the performance of different cost functions/regularization schemes in solving the fluorescence tomographic problem. The simplified spherical harmonics approximation is used to accurately model light propagation inside the tissue. Furthermore, a multigrid mesh is utilized to decrease the dimension of the inverse problem and reduce the computational cost of the solution. The inverse problem is solved iteratively using an lm-BFGS quasi-Newton optimization method. The simulations are performed under different scenarios of noisy measurements. These are carried out on the Digimouse numerical mouse model with the kidney being the target organ. The evaluation of the reconstructed images is performed both qualitatively and quantitatively using several metrics including QR, RMSE, CNR, and TVE under rigorous conditions. The best reconstruction results under different scenarios are obtained with an L1.5 -L1 scheme with premature termination of the optimization process. This is in contrast to approaches commonly found in the literature relying on L2 -L2 schemes.

  1. A new low-turbulence wind tunnel for animal and small vehicle flight experiments

    OpenAIRE

    Quinn, Daniel B.; Watts, Anthony; Nagle, Tony; Lentink, David

    2017-01-01

    Our understanding of animal flight benefits greatly from specialized wind tunnels designed for flying animals. Existing facilities can simulate laminar flow during straight, ascending and descending flight, as well as at different altitudes. However, the atmosphere in which animals fly is even more complex. Flow can be laminar and quiet at high altitudes but highly turbulent near the ground, and gusts can rapidly change wind speed. To study flight in both laminar and turbulent environments, a...

  2. Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid Arthritis

    Science.gov (United States)

    2015-10-01

    objectives are to further test this hypothesis in the AIA model as well as in another established animal model of RA, the collagen type-II induced...onset) and day +16 (disease peak) sera tested regardless of the animal treatment protocol (data not shown). Responsible PI: Yoel Kloog, Tel Aviv...studies are associated with substantial distress to the animals , and given our duty to balance the needs of the study with that of the welfare of

  3. Development and evaluation of an online computer-aided learning (CAL) package to promote small-animal welfare.

    Science.gov (United States)

    Denwood, Matthew; Dale, Vicki H M; Yam, Philippa

    2008-01-01

    The aims of the study, conducted as a student research project in the 2004-5 session, were to develop an interactive, online computer-aided learning (CAL) package on the topic of small-animal husbandry; to validate the resource as a suitable lecture replacement for first-year veterinary students; and to raise awareness of current guidelines and legislation relating to small-animal housing among local catteries and kennels and in the wider community. Quantitative feedback was collected from student and teaching staff using paper-based questionnaires. Qualitative feedback was gathered from open questionnaire responses and through focus-group discussions with students. Student examination marks were compared for 2004 and 2005, allowing a comparison of student performance before and after the replacement of the traditional lecture with the CAL package. Ethical approval for the study was granted by the faculty's Ethics Committee. The CAL package on small-animal housing was well received by teaching staff and students; student performance in examinations improved after the introduction of the CAL program, suggesting that it provides a suitable alternative to didactic teaching. The creation and distribution of the CAL package on CD-ROM and its availability via the Internet are intended to contribute to small-animal welfare education in local catteries and kennels and further afield. The package sets a precedent for the development of more Internet-based, student-authored CAL packages in the future, providing additional resources for independent learning.

  4. Attitudes of Austrian veterinarians towards euthanasia in small animal practice: impacts of age and gender on views on euthanasia.

    Science.gov (United States)

    Hartnack, Sonja; Springer, Svenja; Pittavino, Marta; Grimm, Herwig

    2016-02-04

    Euthanasia of pets has been described by veterinarians as "the best and the worst" of the profession. The most commonly mentioned ethical dilemmas veterinarians face in small animal practice are: limited treatment options due to financial constraints, euthanizing of healthy animals and owners wishing to continue treatment of terminally ill animals. The aim of the study was to gain insight into the attitudes of Austrian veterinarians towards euthanasia of small animals. This included assessing their agreement with euthanasia in exemplified case scenarios, potentially predicted by demographic variables (e.g. gender, age, working in small animal practice, employment, working in a team, numbers of performed euthanasia). Further describing the veterinarians' agreement with a number of different normative and descriptive statements, including coping strategies. A questionnaire with nine euthanasia scenarios, 26 normative and descriptive statements, and demographic data were sent to all members of the Austrian Chamber of Veterinary Surgeons (n = 2478). In total, 486 veterinarians answered sufficiently completely to enable analyses. Responses were first explored descriptively before being formally analysed using linear regression and additive Bayesian networks - a multivariate regression methodology - in order to identify joint relationships between the demographic variables, the statements and each of the nine euthanasia scenarios. Mutual dependencies between the demographic variables were found, i.e. female compared to male veterinarians worked mostly in small animal practice, and working mostly in small animal practice was linked to performing more euthanasia per month. Gender and age were found to be associated with views on euthanasia: female veterinarians and veterinarians having worked for less years were more likely to disagree with euthanasia in at least some of the convenience euthanasia scenarios. The number of veterinarians working together was found to be

  5. Imaging of lung metastasis tumor mouse model using [{sup 18}F]FDG small animal PET and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Youp; Woo, Sang Keun; Lee, Tae Sup [Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)] (and others)

    2007-02-15

    The purpose of this study is to image metastaic lung melanoma model with optimal pre-conditions for animal handling by using [{sup 18}F]FDG small animal PET and clinical CT. The pre-conditions for lung region tumor imaging were 16-22 h fasting and warming temperature at 30 .deg. C. Small animal PET image was obtained at 60 min postinjection of 7.4 MBq [{sup 18}F]FDG and compared pattern of [{sup 18}F]FDG uptake and glucose standard uptake value (SUVG) of lung region between Ketamine/Xylazine (Ke/Xy) and Isoflurane (Iso) anesthetized group in normal mice. Metastasis tumor mouse model to lung was established by intravenous injection of B16-F10 cells in C57BL/6 mice. In lung metastasis tumor model, [{sup 18}F]FDG image was obtained and fused with anatomical clinical CT image. Average blood glucose concentration in normal mice were 128.0 {+-} 22.87 and 86.0 {+-} 21.65 mg/dL in Ke/Xy group and Iso group, respectively. Ke/Xy group showed 1.5 fold higher blood glucose concentration than Iso group. Lung to Background ratio (L/B) in SUVG image was 8.6 {+-} 0.48 and 12.1 {+-}0.63 in Ke/Xy group and Iso group, respectively. In tumor detection in lung region, [{sup 18}F]FDG image of Iso group was better than that of Ke/Xy group, because of high L/B ratio. Metastatic tumor location in [{sup 18}F]FDG small animal PET image was confirmed by fusion image using clinical CT. Tumor imaging in small animal lung region with [{sup 18}F]FDG small animal PET should be considered pre-conditions which fasting, warming and an anesthesia during [{sup 18}F]FDG uptake. Fused imaging with small animal PET and CT image could be useful for the detection of metastatic tumor in lung region.

  6. Small animal PET based on 16x16 TSV-MPPCs and monolithic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Antonio; Aguilar, Albert Talens; Conde, Pablo; Hernadez, Liczandro Hernadez; Vidal San Sebastian, Luis Fernando [Institute for Instrumentation in Molecular Imaging, i3M-CSIC, Valencia (Spain); Salbador, Carlos Correcher; Solsona, Cesar Molinos [Oncovision, Valencia (Spain); Junge, Sven; Lankes, Konrad [Bruker BioSpin (Germany); Benlloch, Jose Maria [Institute for Instrumentation in Molecular Imaging, i3M-CSIC, Valencia (Spain)

    2015-05-18

    In this work we present the design of a small animal PET based on 8 high-density arrays of MPPCs and monolithic scintillators. The MPPCs arrays are composed of 16x16 TSV-type (3x3 mm{sup 2}) elements covering a rough active area of 5x5 cm{sup 2}. A single LYSO block with a thickness of 10mm has been mounted on each detector. Black paint has been applied to the entrance and lateral faces of the crystal to preserve the scintillation light distribution. The axial and transaxial FOVs of one ring are 48 mm and 80 mm, respectively. Each MPPC array has been directly attached to a resistive readout circuit that provides outputs for each row and column of the array. These 32 signals are read with flexible boards 30 cm apart from the PET detector without any additional connectors in between. The PET-system is intended for in-line acquisition in front of MR scanners and as PET-insert inside the sensitive MRI volume. For this purpose, it is necessary to avoid magnetic sensible materials, such as nickel, and to prevent eddy currents in metallic structures induced by the MRI gradients. All detectors are air cooled and kept at temperatures of approximately 20{sup o}C with a variation below 0.05{sup o}C. The intrinsic resolution is 2.2 mm at the crystal center (averaged over all 2.6 mm) when Center of Gravity methods are used to resolve the impact position. This value is about a factor 1.5 better than results obtained with the H8500 PSPMT (64 PADs) and similar scintillators. With an improved collimator with holes with only 0.8mm diameter and a length of 70 mm, an intrinsic detector resolution of 1.1mm was reached. The energy resolutions of ROIs of 1x1 cm{sup 2} showed FWHM values in the range of 14%.

  7. Biological effects of high strength electric fields on small laboratory animals. Interim progress report, March 9, 1976--September 8, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, R.D.; Kaune, W.T.; Decker, J.R.; Hjeresen, D.L.

    1976-09-01

    Progress is reported on a broad and comprehensive series of biological experiments made under strictly controlled laboratory conditions to screen for possible effects of exposure to 60-Hz electric fields on small laboratory animals. Electric field strengths comparable to and exceeding those under existing and anticipated transmission line designs will be used. Dosimetry studies will complement the animal studies to establish the relationship between tissue dose and any observed biological effects. Information derived from this project will provide a better basis for evaluating potential hazards of exposure to 60-Hz electric fields and help define parameters to be studied in clinical evaluations on humans.

  8. Anesthesia condition for {sup 18}F-FDG imaging of lung metastasis tumors using small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang-Keun; Lee, Tae Sup; Kim, Kyeong Min; Kim, June-Youp; Jung, Jae Ho; Kang, Joo Hyun [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Cheon, Gi Jeong [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of)], E-mail: larry@kcch.re.kr; Choi, Chang Woon; Lim, Sang Moo [Division of Nuclear Medicine and RI Application, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of); Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences (KIRAMS), Nowon-Gu, Seoul 139-706 (Korea, Republic of)

    2008-01-15

    Small animal positron emission tomography (PET) with {sup 18}F-FDG has been increasingly used for tumor imaging in the murine model. The aim of this study was to establish the anesthesia condition for imaging of lung metastasis tumor using small animal {sup 18}F-FDG PET. Methods: To determine the impact of anesthesia on {sup 18}F-FDG distribution in normal mice, five groups were studied under the following conditions: no anesthesia, ketamine and xylazine (Ke/Xy), 0.5% isoflurane (Iso 0.5), 1% isoflurane (Iso 1) and 2% isoflurane (Iso 2). The ex vivo counting, standard uptake value (SUV) image and glucose SUV of {sup 18}F-FDG in various tissues were evaluated. The {sup 18}F-FDG images in the lung metastasis tumor model were obtained under no anesthesia, Ke/Xy and Iso 0.5, and registered with CT image to clarify the tumor region. Results: Blood glucose concentration and muscle uptake of {sup 18}F-FDG in the Ke/Xy group markedly increased more than in the other groups. The Iso 2 group increased {sup 18}F-FDG uptake in heart compared with the other groups. The Iso 0.5 anesthesized group showed the lowest {sup 18}F-FDG uptake in heart and chest wall. The small size of lung metastasis tumor (2 mm) was clearly visualized by {sup 18}F-FDG image with the Iso 0.5 anesthesia. Conclusion: Small animal {sup 18}F-FDG PET imaging with Iso 0.5 anesthesia was appropriate for the detection of lung metastasis tumor. To acquire {sup 18}F-FDG PET images with small animal PET, the type and level of anesthetic should be carefully considered to be suitable for the visualization of target tissue in the experimental model.

  9. Small guide to using drugs in laboratory animals, birds and reptiles

    Directory of Open Access Journals (Sweden)

    Viorica Chiurciu,

    2012-06-01

    Full Text Available Laboratory animals (namely, mouse, rat, hamster, guinea pig, rabbit, chinchillas, birds and reptilian medicine is a relatively new specialty of veterinary medicine, being until recently in the "early" stages, therefore at least in the last decade, some studies on these types of animals appeared in the literature and cosecquently, therapy issues of various disease states in these animals. Besides the fact that laboratory animals and reptiles are used in biomedical research, we would say, already routinely not to neglect is the growing number of holders of such "pet animals". In search of appropriate dosages to theese species, scientists have tried to extrapolate doses from dogand cats, based on experimental studies and then published. Based on "accumulation" of therapists in the recent years, only few drugs have been approved yet (especially for rodents, most of them having still the status application beside instructions (off-label application. Already known increased susceptibility of mice and rabbits to the toxicity of antimicrobials is particularly important due to intestinal flora, dismicrobism due to the narrow spectrum antibiotics often leading to the increasing of gram-negative and gram positive anaerobic, organisms which will induce in these species toxicity and death. In conclusion, dosages presented are the result of some clinical studies that could be yet considered as "empirical" and "extrapolated from other species" and which are perfectible every day by the information accumulation following the administrations. In this respect an "up to date" self-improvement of vet specialists who have interests in this field is required.

  10. Anesthetic experimental device for small animal Aparelho de anestesia experimental para animais de pequeno porte

    Directory of Open Access Journals (Sweden)

    Luiz Alfredo de Magalhães Vivas

    2007-06-01

    Full Text Available PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes. METHODS: The new components of the equipment were: the vaporizer, the unidirectional valve, the glass cylinder filled with water, the flow guidance y-shape tube, the flow regulators, the mask modifications, and another free airway for emergency occurrence. A test was done with 30 Wistar rats, Rattus norvegicus albinus, divided into three groups with 10 rats for each one. Groups 1, 2 and 3 were anesthetized with Ether, Halothane and Sevoflurane respectively, using the new gadget. The anesthetic induction time, the breathing rhythm alteration during an anesthesia pre-established time (10 minutes, and the recovery time were observed. RESULTS: The equipment enabled an easy handling, and fulfilled a larger safeness and stability during the induction and anesthetic management. The test showed it was possible to make use of several anesthetic agents. CONCLUSION: The device is effective, and turns the anesthesia procedure into a very easy practice with low-cost. It should be recommended for experimental surgery, teaching and research.OBJETIVOS: As dificuldades evidenciadas no uso de vaporizadores para anestesia em animais de pequeno porte motivaram o aperfeiçoamento e a criação de novos componentes técnicos visando a construção de um aparelho de anestesia de baixo custo, prático e versátil no manuseio e que atenda aos preceitos éticos do ensino e da pesquisa. MÉTODOS: Utilizaram-se 30 ratos da linhagem Wistar, Rattus norvegicus albinus, distribuídos em três grupos. Grupo 1,2 e 3 (n=10, cada, compreenderam o uso do novo aparelho aduzido, respectivamente, do Éter; Halotano e Sevoflurano. Foram verificados o tempo de indução anest

  11. Preclinical molecular imaging: development of instrumentation for translational research with small laboratory animals.

    Science.gov (United States)

    Mejia, Jorge; Miranda, Ana Claudia Camargo; Durante, Ana Claudia Ranucci; Oliveira, Larissa Rolim de; Barboza, Marycel Rosa Felisa Figols de; Rosell, Katerin Taboada; Jardim, Daniele Pereira; Campos, Alexandre Holthausen; Reis, Marilia Alves Dos; Catanoso, Marcela Forli; Galvis-Alonso, Orfa Yineth; Cabral, Francisco Romero

    2016-01-01

    To present the result of upgrading a clinical gamma-camera to be used to obtain in vivo tomographic images of small animal organs, and its application to register cardiac, renal and neurological images. An updated version of the miniSPECT upgrading device was built, which is composed of mechanical, electronic and software subsystems. The device was attached to a Discovery VH (General Electric Healthcare) gamma-camera, which was retired from the clinical service and installed at the Centro de Imagem Pré-Clínica of the Hospital Israelita Albert Einstein. The combined system was characterized, determining operational parameters, such as spatial resolution, magnification, maximum acceptable target size, number of projections, and acquisition and reconstruction times. Images were obtained with 0.5mm spatial resolution, with acquisition and reconstruction times between 30 and 45 minutes, using iterative reconstruction with 10 to 20 iterations and 4 projection subsets. The system was validated acquiring in vivo tomographic images of the heart, kidneys and brain of normal animals (mice and adult rats), using the radiopharmaceuticals technetium-labeled hexakis-2-methoxy-isobutyl isonitrile (99mTc-Sestamibi), technetium-labeled dimercaptosuccinic acid (99mTc-DMSA) and technetium-labeled hexamethyl propyleneamine oxime (99mTc-HMPAO). This kind of application, which consists in the adaptation for an alternative objective of already existing instrumentation, resulted in a low-cost infrastructure option, allowing to carry out large scale in vivo studies with enhanced quality in several areas, such as neurology, nephrology, cardiology, among others. Apresentar o resultado da adaptação de uma gama câmara clínica para uso dedicado na obtenção de imagens tomográficas in vivo de órgãos de pequenos animais de experimentação, e de sua aplicação na obtenção de imagens cardíacas, renais e neurológicas. Foi construída uma versão atualizada do dispositivo de adapta

  12. Low cost venom extractor based on Arduino(®) board for electrical venom extraction from arthropods and other small animals.

    Science.gov (United States)

    Besson, Thomas; Debayle, Delphine; Diochot, Sylvie; Salinas, Miguel; Lingueglia, Eric

    2016-08-01

    Extracting venom from small species is usually challenging. We describe here an affordable and versatile electrical venom extractor based on the Arduino(®) Mega 2560 Board, which is designed to extract venom from arthropods and other small animals. The device includes fine tuning of stimulation time and voltage. It was used to collect venom without apparent deleterious effects, and characterized for the first time the venom of Zoropsis spinimana, a common spider in French Mediterranean regions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

    Science.gov (United States)

    Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao

    2016-01-01

    Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.

  14. Factors associated with development of Canine Infectious Respiratory Disease Complex (CIRDC) in dogs in 5 Canadian small animal clinics.

    Science.gov (United States)

    Joffe, Daniel J; Lelewski, Roxana; Weese, J Scott; Mcgill-Worsley, Jamie; Shankel, Catharine; Mendonca, Sonia; Sager, Tara; Smith, Michael; Poljak, Zvonimir

    2016-01-01

    This study investigated the association between presence of respiratory pathogens and development of Canine Infectious Respiratory Disease Complex (CIRDC) in dogs in 5 Canadian small animal clinics. In total, 86 dogs were tested using a commercial PCR respiratory panel; 64 dogs were considered as cases and 22 were control dogs matched by veterinary clinic. No control animals (0/22) were positive for canine parainfluenza virus (CPIV), whereas 27/64 (42%) CIRDC cases were positive. Furthermore, 81% of case dogs tested positive for Mycoplasma cynos, compared with 73% of control dogs. Canine respiratory corona virus (CRCoV) was detected in no control dogs compared with 9.4% of clinical dogs. No animals were positive for any influenza virus type A present in the diagnostic panel. Presence of CPIV was associated (P < 0.01) with the occurrence of CIRDC after adjustment for demographic factors and presence of CRCoV (P = 0.09).

  15. Experimental Evaluation of Depth-of-Interaction Correction in a Small-Animal Positron Emission Tomography Scanner

    OpenAIRE

    Green, Michael V.; Ostrow, Harold G.; Seidel, Jurgen; Pomper, Martin G.

    2010-01-01

    Human and small-animal positron emission tomography (PET) scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This “depth-of-interaction” (DOI) effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experim...

  16. Imaging optimizations with non-pure and high-energy positron emitters in small animal positron computed tomography

    International Nuclear Information System (INIS)

    Harzmann, Sophie

    2014-01-01

    The contribution on imaging optimizations with non-pure and high-energy positron emitters in small animal positron emission tomography (PET) covers the following topics: physical fundamentals of PET, mathematical image reconstruction and data analyses, Monte-Carlo simulations and implemented correction scheme, quantification of cascade gamma coincidences based on simulations and measurements, sinogram based corrections, restoration of the spatial resolution, implementation of full corrections.

  17. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A. Joe [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G., E-mail: PMaxim@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2017-01-01

    Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

  18. Counseling with Pocket Pets: Using Small Animals in Elementary Counseling Programs

    Science.gov (United States)

    Flom, Barbara L.

    2005-01-01

    The power of the human-animal bond has been described in sources as diverse as ancient literature, modern fiction, and research reports in the professional literature (Chandler, 2001; Mallon, 1992; Parshall, 2003; Siegel, 1993). Educators have used classic examples, such as those found in the children's books Old Yeller and Where the Red Fern…

  19. Creatures in the Classroom: Including Insects and Small Animals in Your Preschool Gardening Curriculum

    Science.gov (United States)

    Hachey, Alyse C.; Butler, Deanna

    2012-01-01

    When doing spring planting activities, what does a teacher do while waiting for the plants to grow? This waiting time is a golden opportunity to explore another side of gardening--the creatures that make it all possible. Insects are an integral part of everyday world, having existed for over 300 million years; they are the most common animal on…

  20. Nigerian Veterinary Journal The record of J 14small animal trauma ...

    African Journals Online (AJOL)

    rapidly organize definitive therapy,. Traumas from various causes are recognized as frequent causes of injury to pet animals. However, there is paucity of information concerning the patterns of injuries associated with various causes of trauma in referral Veterinary centers in. Nigeria. This article presents the results of a.

  1. Diagnosis and therapy of oral cavity diseases in small domestic animals

    Directory of Open Access Journals (Sweden)

    Krstić Nikola

    2002-01-01

    Full Text Available In parallel with the stepped up urbanisation of modern man, there is an increasing number of house pets of different breeds and species who suffer certain biological and physiological changes because of the specific manner of breeding and upkeep. The altered conditions of their natural environment can lead to disorders in the animal genetic fund, which is why numerous diseases include cases of constitutional flaws (caries, periodontosis and related complications, cysts, abscesses, malformations of hereditary origin - hypodontia, andontia, impacted teeth, and others. The paper presents cases of the most frequent diseases of teeth and supporting tissues, as well as the optimal manner of therapy. It also points out certain limitations in practicing veterinary orthodontia aimed at avoiding situations when certain congenital or acquired anomalies are corrected but result in the animal no longer meeting the required standards for its species.

  2. Bird and Small Animal Tracking Using a GSM-based System

    Directory of Open Access Journals (Sweden)

    Samuel Matos

    2015-11-01

    Full Text Available This paper describes a prototype of a system designed to track animals, goods or persons. The system is based exclusively on Global System for Mobile Communications (GSM services, which are presently widespread. Its advantages and drawbacks are also discussed. The system itself consists of two independent parts: the base device and the location device. The location device is the part actually attached to the animal, good or person being tracked. It combines reduced size and weight with extended range. The base device can deal with one or more location devices. Its role is to receive the Short Message Service (SMS sent by the location devices and forward them to an application that decodes and stores the location data in a database. Since energy considerations and testing are fundamental in this context, we present detailed energy consumption profiles and the computer applications developed to test the system. We also discuss the results of practical tests with wild and captive birds.

  3. The evolution of juvenile animal testing for small and large molecules.

    Science.gov (United States)

    Baldrick, Paul

    2013-11-01

    Recent formalised regulatory requirements for ensuring safe use of new drugs in children has increased the requirement, when considered relevant, to perform juvenile animal testing before commencing paediatric clinical trials. A key goal of this work is to identify or examine for a developmental or toxicity finding not seen in other toxicology testing. With our current knowledge, this paper examines what types of testing are occurring, what novel findings are being seen and their relevance in the safety evaluation process. Furthermore, trends for now and the future in the type of juvenile animal testing will be described including a need for more focused study designs and more published data on modern cross-species postnatal development. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. An accurate and portable eye movement detector for studying sleep in small animals.

    Science.gov (United States)

    Sánchez-López, Álvaro; Escudero, Miguel

    2015-08-01

    Although eye movements are a highly valuable variable in attempts to precisely identify different periods of the sleep-wake cycle, their indirect measurement by electrooculography is not good enough. The present article describes an accurate and portable scleral search coil that allows the detection of tonic and phasic characteristics of eye movements in free-moving animals. Six adult Wistar rats were prepared for chronic recording of electroencephalography, electromyography and eye movements using the scleral search coil technique. We developed a miniature magnetic field generator made with two coils, consisting of 35 turns and 15 mm diameter of insulated 0.2 mm cooper wire, mounted in a frame of carbon fibre. This portable scleral search coil was fixed on the head of the animal, with each magnetic coil parallel to the eye coil and at 5 mm from each eye. Eye movements detected by the portable scleral search coil were compared with those measured by a commercial scleral search coil requiring immobilizing the head of the animal. No qualitative differences were found between the two scleral search coil systems in their capabilities to detect eye movements. This innovative portable scleral search coil system is an essential tool to detect slow changes in eye position and miniature rapid eye movements during sleep. The portable scleral search coil is much more suitable for detecting eye movements than any previously available system because of its precision and simplicity, and because it does not require immobilization of the animal's head. © 2015 European Sleep Research Society.

  5. Pencilbeam irradiation technique for whole brain radiotherapy: technical and biological challenges in a small animal model.

    Science.gov (United States)

    Schültke, Elisabeth; Trippel, Michael; Bräuer-Krisch, Elke; Renier, Michel; Bartzsch, Stefan; Requardt, Herwig; Döbrössy, Máté D; Nikkhah, Guido

    2013-01-01

    We have conducted the first in-vivo experiments in pencilbeam irradiation, a new synchrotron radiation technique based on the principle of microbeam irradiation, a concept of spatially fractionated high-dose irradiation. In an animal model of adult C57 BL/6J mice we have determined technical and physiological limitations with the present technical setup of the technique. Fifty-eight animals were distributed in eleven experimental groups, ten groups receiving whole brain radiotherapy with arrays of 50 µm wide beams. We have tested peak doses ranging between 172 Gy and 2,298 Gy at 3 mm depth. Animals in five groups received whole brain radiotherapy with a center-to-center (ctc) distance of 200 µm and a peak-to-valley ratio (PVDR) of ∼ 100, in the other five groups the ctc was 400 µm (PVDR ∼ 400). Motor and memory abilities were assessed during a six months observation period following irradiation. The lower dose limit, determined by the technical equipment, was at 172 Gy. The LD50 was about 1,164 Gy for a ctc of 200 µm and higher than 2,298 Gy for a ctc of 400 µm. Age-dependent loss in motor and memory performance was seen in all groups. Better overall performance (close to that of healthy controls) was seen in the groups irradiated with a ctc of 400 µm.

  6. Assessing Monkeypox Virus Prevalence in Small Mammals at the Human–Animal Interface in the Democratic Republic of the Congo

    Directory of Open Access Journals (Sweden)

    Jeffrey B. Doty

    2017-10-01

    Full Text Available During 2012, 2013 and 2015, we collected small mammals within 25 km of the town of Boende in Tshuapa Province, the Democratic Republic of the Congo. The prevalence of monkeypox virus (MPXV in this area is unknown; however, cases of human infection were previously confirmed near these collection sites. Samples were collected from 353 mammals (rodents, shrews, pangolins, elephant shrews, a potamogale, and a hyrax. Some rodents and shrews were captured from houses where human monkeypox cases have recently been identified, but most were trapped in forests and agricultural areas near villages. Real-time PCR and ELISA were used to assess evidence of MPXV infection and other Orthopoxvirus (OPXV infections in these small mammals. Seven (2.0% of these animal samples were found to be anti-orthopoxvirus immunoglobulin G (IgG antibody positive (six rodents: two Funisciurus spp.; one Graphiurus lorraineus; one Cricetomys emini; one Heliosciurus sp.; one Oenomys hypoxanthus, and one elephant shrew Petrodromus tetradactylus; no individuals were found positive in PCR-based assays. These results suggest that a variety of animals can be infected with OPXVs, and that epidemiology studies and educational campaigns should focus on animals that people are regularly contacting, including larger rodents used as protein sources.

  7. Small animal imaging using a flat panel detector-based cone beam computed tomography (FPD-CBCT) imaging system

    Science.gov (United States)

    Conover, David L.; Ning, Ruola; Yu, Yong; Lu, Xianghua; Wood, Ronald W.; Reeder, Jay E.; Johnson, Aimee M.

    2005-04-01

    Flat panel detector-based cone beam CT (FPD-CBCT) imaging system prototypes have been constructed based on modified clinical CT scanners (a modified GE 8800 CT system and a modified GE HighSpeed Advantage (HSA) spiral CT system) each with a Varian PaxScan 2520 imager. The functions of the electromechanical and radiographic subsystems of the CT system were controlled through specially made hardware, software and data acquisition modules to perform animal cone beam CT studies. Small animal (mouse) imaging studies were performed to demonstrate the feasibility of an optimized CBCT imaging system to have the capability to perform longitudinal studies to monitor the progression of cancerous tumors or the efficacy of treatments. Radiographic parameters were optimized for fast (~10 second) scans of live mice to produce good reconstructed image quality with dose levels low enough to avoid any detectable radiation treatment to the animals. Specifically, organs in the pelvic region were clearly imaged and contrast studies showed the feasibility to visualize small vasculature and space-filling bladder tumors. In addition, prostate and mammary tumors were monitored in volume growth studies.

  8. Assessing monkeypox virus prevalence in small mammals at the human-animal interface in the Democratic Republic of the Congo

    Science.gov (United States)

    Doty, Jeffrey B.; Malekani, Jean M.; Kalemba, Lem's N.; Stanley, William T.; Monroe, Benjamin P.; Nakazawa, Yoshinori J.; Mauldin, Matthew R.; Bakambana, Trésor L.; Liyandja Dja Liyandja , Tobit; Braden, Zachary; Wallace, Ryan; Malekani, Divin V.; McCollum, Andrea M.; Gallardo-Romero, Nadia; Kondas, Ashley; Peterson, A. Townsend; Osorio, Jorge E.; Rocke, Tonie E.; Karem, Kevin L.; Emerson, Ginny L.; Carroll, Darin S.

    2017-01-01

    During 2012, 2013 and 2015, we collected small mammals within 25 km of the town of Boende in Tshuapa Province, the Democratic Republic of the Congo. The prevalence of monkeypox virus (MPXV) in this area is unknown; however, cases of human infection were previously confirmed near these collection sites. Samples were collected from 353 mammals (rodents, shrews, pangolins, elephant shrews, a potamogale, and a hyrax). Some rodents and shrews were captured from houses where human monkeypox cases have recently been identified, but most were trapped in forests and agricultural areas near villages. Real-time PCR and ELISA were used to assess evidence of MPXV infection and other Orthopoxvirus (OPXV) infections in these small mammals. Seven (2.0%) of these animal samples were found to be anti-orthopoxvirus immunoglobulin G (IgG) antibody positive (six rodents: two Funisciurus spp.; one Graphiurus lorraineus; one Cricetomys emini; one Heliosciurus sp.; one Oenomys hypoxanthus, and one elephant shrew Petrodromus tetradactylus); no individuals were found positive in PCR-based assays. These results suggest that a variety of animals can be infected with OPXVs, and that epidemiology studies and educational campaigns should focus on animals that people are regularly contacting, including larger rodents used as protein sources. 

  9. Osteoarthritis and a high-fat diet: the full 'OA syndrome' in a small animal model

    OpenAIRE

    van der Kraan, Peter M

    2010-01-01

    Obesity is one of the main risk factors for osteoarthritis (OA) and due to the global rise in obesity this will increasingly contribute to OA development. The article of Griffin and co-workers in this issue of Arthritis Research and Therapy shows that a high-fat diet leads to obesity and OA in the studied animals and that this is related to alterations in locomotor function. Furthermore, a high-fat diet leads to pain sensitization and depression/anxiety-like behavior unrelated to structural O...

  10. Technical Note: System for evaluating local hypothermia as a radioprotector of the rectum in a small animal model.

    Science.gov (United States)

    Hrycushko, Brian A; Bing, Chenchen; Futch, Cecil; Wodzak, Michelle; Stojadinovic, Strahinja; Medin, Paul M; Chopra, Rajiv

    2017-08-01

    The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) treatments. This work describes the development of a system to evaluate local hypothermia for a radioprotective effect of the rat rectum during a large dose of radiation relevant to prostate SBRT. This includes the evaluation of a 3D-printed small animal rectal cooling device and the integration with a small animal irradiator. A 3-cm long, dual-lumen rectal temperature control apparatus (RTCA) was designed in SOLIDWORKS CAD for 3D printing. The RTCA was capable of recirculating flow in a device small enough for insertion into the rat rectum, with a metal support rod for strength as well as visibility during radiation treatment planning. The outer walls of the RTCA comprised of thin heat shrink plastic, achieving efficient heat transfer into adjacent tissues. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within the rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. Integration with an image-guided small animal irradiator and associated treatment planning system included evaluation for imaging artifacts and effect of brass tubing on dose calculation. The rectal temperature adjacent to the cooling device decreased from body temperature to 15°C within 10-20 min from device insertion and was maintained at 15 ± 3°C during active cooling for the evaluated time of one hour. MR thermometry revealed a steep temperature gradient with increasing distance from the cooling device with the desired

  11. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  12. A restraint-free small animal SPECT imaging system with motion tracking

    Energy Technology Data Exchange (ETDEWEB)

    Weisenberger, A.G.; Gleason, S.S.; Goddard, J.; Kross, B.; Majewski, S.; Meikle, S.R.; Paulus, M.J.; Pomper, M.; Popov, V.; Smith, M.F.; Welch, B.L.; Wojcik, R.

    2005-06-01

    We report on an approach toward the development of a high-resolution single photon emission computed tomography (SPECT) system to image the biodistribution of radiolabeled tracers such as Tc-99m and I-125 in unrestrained/unanesthetized mice. An infrared (IR)-based position tracking apparatus has been developed and integrated into a SPECT gantry. The tracking system is designed to measure the spatial position of a mouse's head at a rate of 10-15 frames per second with submillimeter accuracy. The high-resolution, gamma imaging detectors are based on pixellated NaI(Tl) crystal scintillator arrays, position-sensitive photomultiplier tubes, and novel readout circuitry requiring fewer analog-digital converter (ADC) channels while retaining high spatial resolution. Two SPECT gamma camera detector heads based upon position-sensitive photomultiplier tubes have been built and installed onto the gantry. The IR landmark-based pose measurement and tracking system is under development to provide animal position data during a SPECT scan. The animal position and orientation data acquired by the tracking system will be used for motion correction during the tomographic image reconstruction.

  13. An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals.

    Science.gov (United States)

    Gilchrist, Stuart; Gomes, Ana L; Kinchesh, Paul; Kersemans, Veerle; Allen, Philip D; Smart, Sean C

    2016-01-01

    To develop an MRI-compatible resistive heater, using high frequency alternating current (AC), for temperature maintenance of anaesthetised animals. An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10-100 kHz) AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice. Images and spectra acquired in the presence and absence of 50-100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse's temperature approached the set target. The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality.

  14. An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals.

    Directory of Open Access Journals (Sweden)

    Stuart Gilchrist

    Full Text Available To develop an MRI-compatible resistive heater, using high frequency alternating current (AC, for temperature maintenance of anaesthetised animals.An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10-100 kHz AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice.Images and spectra acquired in the presence and absence of 50-100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse's temperature approached the set target.The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality.

  15. Occupational exposure assessment in procedures of portable digital veterinary radiology for small size animals

    International Nuclear Information System (INIS)

    Canato, G.R.; Drumond, L.F.; Paschuk, S.A.; Asfora, V.K.; Andrade, M.E.A.; Denyak, V.; Schelin, H.R.

    2014-01-01

    This study evaluates the dose received by veterinarians and assistants involved in portable digital veterinary radiology procedures and checks the dose reduction obtained with the use of individual protection equipment. For this evaluation measurements were made using thermoluminescent dosimeters TLD-100, positioned at different parts of the body: hands, thorax, thyroids, gonads, left and right eye corners and at the center of the eyes. The dose was evaluated through 65 procedures performed with 55 animals. The results showed that in the case of assistants the received dose is significantly larger than that of the veterinarian. The most likely reason of this effect is that they are closer to the primary beam and thus are exposed to higher level of primary radiation first of all in regions of eyes and thyroids. The doses received by various body parts of the assistant are close to the annual limit recommended by International Commission on Radiological Protection. - Highlights: • The occupational dose in portable digital veterinary radiology was studied. • The dose was evaluated through 65 procedures performed with 55 animals. • The dose received by assistants is significantly larger than by the veterinarian. • The doses at various body parts of the assistant are close to the limit of ICRP

  16. Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid Arthritis

    Science.gov (United States)

    2016-10-01

    arthritis (AIA) model by all outcome parameters(Clinical assessment and relevant laboratory/ immunological /Molecular analyses). (II) Prophylactic dosing of...with MTX was coupled with significant "positive" attenuation of multiple relevant immunological and laboratory markers - all strongly implying that the...Farnesylthiosalicylic acid (FTS). This small molecule does not belong to the class of farnesyltransferase inhibitors (FTIs) that failed in clinical trials . It

  17. Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

    International Nuclear Information System (INIS)

    Johnstone, Chris; Bazalova-Carter, Magdalena

    2016-01-01

    Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional data sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.

  18. Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Zeraatkar, Navid; Farahani, Mohammad Hossein [Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran 1419733141 (Iran, Islamic Republic of); Rahmim, Arman [Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21287 and Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Sarkar, Saeed [Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran 1417613151, Iran and Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran 1419733141 (Iran, Islamic Republic of); Ay, Mohammad Reza, E-mail: mohammadreza-ay@sina.tums.ac.ir [Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran 1419733141, Iran and Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran 1417613151 (Iran, Islamic Republic of)

    2016-05-15

    Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as

  19. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    International Nuclear Information System (INIS)

    Brix, G.; Doll, J.; Bellemann, M.E.; Trojan, H.; Haberkorn, U.; Schmidlin, P.; Ostertag, H.

    1997-01-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ''deconvolution'' procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs

  20. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Doll, J. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Bellemann, M.E. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Trojan, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Haberkorn, U. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Schmidlin, P. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany); Ostertag, H. [Research Program ``Radiological Diagnostics and Therapy``, German Cancer Research Center (DKFZ), Heidelberg (Germany)

    1997-07-01

    The purpose of this work was to improve of the spatial resolution of a whole-body PET system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned ``deconvolution`` procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals. (orig./AJ). With 9 figs.

  1. Effects of experimental radiotherapy and hyperthermia on tumors and normal tissues in small animals

    International Nuclear Information System (INIS)

    Wondergem, J.

    1985-01-01

    Experiments on responses of tumors, implanted subcutaneously in the leg, to irradiation alone or combined with heat are reported. The influence of factors modifying the fraction of hypoxic cells (e.g. anesthesia of the animal and tumor volume) is also discussed. The radiosensitivity of developing lung tumors was examined for spontaneous as well as for artificial lung metastases. Both experimental tumor models were compared with regard to their value in experimental radiotherapy. Data obtained on the response of artificial metastases and lung tissue to combined treatment with irradiation and several drugs are presented. Data on damage of the mouse foot, as a result of heat and/or irradiation treatments are presented. In particular the influence of thermotolerance on thermal enhancement of the radiation induced skin reaction was studied. Tolerance of the skin of previously irradiated mice to retreatment with irradiation, to hyperthermia alone and combined with X-rays was assessed. (Auth.)

  2. Fast image reconstruction experiments using small-bore MRI for animals

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Osamu; Seo, Yoshiteru [National Inst. for Physiological Sciences, Okazaki, Aichi (Japan); Kose, Katsumi

    1995-09-01

    Fast image reconstruction experiments were done using a high-speed image processor utilizing a digital signal processor chip (TMS320C30, Texas Instruments Inc) and a 4.7 T MR imager for animals (Biospec 47/40, Bruker Medizintechnik Gmbh). An image refresh time of 3.2s for a 128 x 128 matrix image was achieved using a fast gradient-echo sequence with a TR/TE/flip-angle of 20ms/6ms/30deg. MR images of a phantom and a rat were obtained repetitively and recorded on videotape over a long period. This system shows great promise for interventional MRI and also for the study of non-phasic motion such as movements of the gastrointestinal tract. (author).

  3. Use of thermographic imaging in clinical diagnosis of small animal: preliminary notes

    Directory of Open Access Journals (Sweden)

    Veronica Redaelli

    2014-06-01

    Full Text Available INTRODUCTION. The authors, after a description of the physics of infrared thermographic technique (IRT, analyze the reading of images and the main applications in the veterinary field, compared to the existing literature on the subject and to their experimental researches. IRT lends itself to countless applications in biology, thanks to its characteristics of versatility, lack of invasiveness and high sensitivity. Probably the major limitation to its application in the animal lies in the ease of use and in its extreme sensitivity. MATERIALS AND METHODS. From September 2009 to October 2010, the experimental investigation with the thermo camera took into consideration 110 animals (92 dogs and 18 cats, without any selection criteria. All patients were brought to the Faculty of Veterinary Medicine in Milan University by the owner, to be examined by a specialist, or to undergo one of the following diagnostic procedures: X-rays, computed tomography, or ultrasound examinations; finally some patients were brought in for surgical procedures. With the consent of the owner, 1 to 10 thermographic images were recorded from each clinical case. Results. In this first experimental investigation, thermography has shown a high sensitivity (100%, but a low specificity (44%. This figure excludes the use of thermal imaging technology to replace other imaging techniques such as radiography, computed tomography and magnetic resonance imaging. Furthermore, it does not show any ability to recognize the etiology of the disease, but only the thermal alteration, and this is restricting its use. However, this experimental study has demonstrated that thermography can be used in veterinary medicine, and specifically in dogs and cats. It is hoped that in the field of targeted diseases this technique will become an important tool for diagnostic purposes by using working protocols validated and repeatable.

  4. Application of photostable quantum dots for indirect immunofluorescent detection of specific bacterial serotypes on small marine animals

    International Nuclear Information System (INIS)

    Decho, Alan W; Beckman, Erin M; Chandler, G Thomas; Kawaguchi, Tomohiro

    2008-01-01

    An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae

  5. Scanner calibration of a small animal PET camera based on continuous LSO crystals and flat panel PSPMTs

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Carrilero, V.; Gonzalez, A.J.; Catret, J.; Lerche, Ch.W.; Abellan, D.; Garcia de Quiros, F.; Gimenez, M.; Modia, J.; Sanchez, F.; Pavon, N.; Ros, A.; Martinez, J.; Sebastia, A.

    2007-01-01

    We have constructed a small animal PET with four identical detector modules, each consisting of a continuous LYSO crystal attached to a Position Sensitive Photomultiplier Tube (PSPMT). The dimensions of the continuous crystal are 50x50 mm 2 and 10 mm thickness. The modules are separated 11 cm between each other in the scanner. In this paper we discuss the method used for the calibration of the camera for this special system with continuous detectors. We also present the preliminary values for the main performance parameters such as spatial and energy resolution, and sensitivity of the system

  6. Development of dual-function SPECT and CT probe for small animal imaging

    International Nuclear Information System (INIS)

    Gambhir, Sanjay; Dube, Veeresh; Kheruka, Subash; Kumar, Uttam; Ahmad, Absar

    2010-01-01

    Full text: Different biological queries require different imaging strategies. In imaging this is more dependent not so much on the instruments but on the properties of the imaging agents.The development of dual-function probes for both fluorescence imaging and MRI was recently reported. Nano SPECT-CT, Bioscan system for animal imaging recently procured by our institute motivated us to explore and standardize a dual function probe for such a system. The study has been planned with a view develop a dual capability CT and radiopharmaceutical contrast to facilitate an anatomical and functional images thus combining the good resolution abilities of CT and high sensitivity functional images of SPECT. Method: Radiolabeling, of Bismuth nanocolloid with Technetium-99m was done and confirmation of good binding by instant thin layer chromatography (ITLC) confirmed more than 90% binding. This was injected into male Sprauge Dawley rats and biodistribution image and clearance time from blood was calculated. Confirmation, of Bismuth nano-colloid to act as CT contrast agent was done by performing phantom study at various concentrations in saline, 50 mg/ml, 100 mg/ml, 200 mg/ml and 500 mg/ml at CT tube current of 2.5mA and tube voltage of 140 KVp. Results: As compared to commercial Iodine contrast (375 mg/ml iodine) which was used as standard the average clearance time Bismuth colloid was longer. Its biodistribution was seen in heart, Liver, spleen and kidney. The iodine comparable CT contrast was achieved by 500 mg/ml of Bismuth colloid. 99m Tc-Bismuth colloid imaging on a dedicated animal SPECT-CT (Nano-SPECT, Bioscan) revealed similar biodistribution and in-vivo-stability of labeling. Conclusion: Successful radiolabeling, in-vivo stability and SPECT imaging of 99m Tc-Bismuth colloid along with its potential to impart iodine equivalent contrast raises the possibility of converting 99m-Tc-Bismuth as dual SPECT-CT probe for obtaining functional and anatomical image in pre

  7. Imaging of Small Animal Peripheral Artery Disease Models: Recent Advancements and Translational Potential

    Directory of Open Access Journals (Sweden)

    Jenny B. Lin

    2015-05-01

    Full Text Available Peripheral artery disease (PAD is a broad disorder encompassing multiple forms of arterial disease outside of the heart. As such, PAD development is a multifactorial process with a variety of manifestations. For example, aneurysms are pathological expansions of an artery that can lead to rupture, while ischemic atherosclerosis reduces blood flow, increasing the risk of claudication, poor wound healing, limb amputation, and stroke. Current PAD treatment is often ineffective or associated with serious risks, largely because these disorders are commonly undiagnosed or misdiagnosed. Active areas of research are focused on detecting and characterizing deleterious arterial changes at early stages using non-invasive imaging strategies, such as ultrasound, as well as emerging technologies like photoacoustic imaging. Earlier disease detection and characterization could improve interventional strategies, leading to better prognosis in PAD patients. While rodents are being used to investigate PAD pathophysiology, imaging of these animal models has been underutilized. This review focuses on structural and molecular information and disease progression revealed by recent imaging efforts of aortic, cerebral, and peripheral vascular disease models in mice, rats, and rabbits. Effective translation to humans involves better understanding of underlying PAD pathophysiology to develop novel therapeutics and apply non-invasive imaging techniques in the clinic.

  8. Experimental Evaluation of Depth-of-Interaction Correction in a Small-Animal Positron Emission Tomography Scanner

    Directory of Open Access Journals (Sweden)

    Michael V. Green

    2010-11-01

    Full Text Available Human and small-animal positron emission tomography (PET scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This “depth-of-interaction” (DOI effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experimentally the effects of a particular DOI correction method (dual-scintillator phoswich detectors with pulse shape discrimination implemented in a small-animal PET scanner by comparing the same phantom and same mouse images with and without DOI correction. The results suggest that even this relatively coarse, two-level estimate of radial gamma ray interaction position significantly reduces the DOI parallax error. This study also confirms two less appreciated advantages of DOI correction: a reduction in radial distortion and radial source displacement as a source is moved toward the edge of the field of view and a resolution improvement detectable in the central field of view likely owing to improved spatial sampling.

  9. Experimental evaluation of depth-of-interaction correction in a small-animal positron emission tomography scanner.

    Science.gov (United States)

    Green, Michael V; Ostrow, Harold G; Seidel, Jurgen; Pomper, Martin G

    2010-12-01

    Human and small-animal positron emission tomography (PET) scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This "depth-of-interaction" (DOI) effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experimentally the effects of a particular DOI correction method (dual-scintillator phoswich detectors with pulse shape discrimination) implemented in a small-animal PET scanner by comparing the same phantom and same mouse images with and without DOI correction. The results suggest that even this relatively coarse, two-level estimate of radial gamma ray interaction position significantly reduces the DOI parallax error. This study also confirms two less appreciated advantages of DOI correction: a reduction in radial distortion and radial source displacement as a source is moved toward the edge of the field of view and a resolution improvement detectable in the central field of view likely owing to improved spatial sampling.

  10. Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards

    Science.gov (United States)

    Luo, Weidong; Anashkin, Edward; Matthews, Christopher G.

    2010-02-01

    The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the NU 2 protocol (intended for whole-body PET scanners) cannot be applied without modification due to the compact design of the PEM scanner, we decided to evaluate the NU 4 Standards as an alternative. We obtained the following results: Trans-axial spatial resolution 1.8 mm FWHM for high resolution reconstruction mode and 2.4 mm FWHM for standard resolution reconstruction mode with no significant variation within the field of view. The total system sensitivity was 0.16 cps/Bq. In image quality testing, the uniformity was found to be 3.9% STD at the standard resolution mode and 5.6% at the high resolution mode when measured with a 34 mm paddle separation. The NEMA NU 4-2008 Standards were found to be a practicable tool to evaluate the performance of the PEM scanner after some modifications to address the specifics of its detector configuration. Furthermore, the PEM scanner's in-plane spatial resolution was comparable to other small animal PET scanners with good image quality.

  11. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    Science.gov (United States)

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  12. Owners and Veterinary Surgeons in the United Kingdom Disagree about What Should Happen during a Small Animal Vaccination Consultation.

    Science.gov (United States)

    Belshaw, Zoe; Robinson, Natalie J; Dean, Rachel S; Brennan, Marnie L

    2018-01-18

    Dog and cat vaccination consultations are a common part of small animal practice in the United Kingdom. Few data are available describing what happens during those consultations or what participants think about their content. The aim of this novel study was to investigate the attitudes of dog and cat owners and veterinary surgeons towards the content of small animal vaccination consultations. Telephone interviews with veterinary surgeons and pet owners captured rich qualitative data. Thematic analysis was performed to identify key themes. This study reports the theme describing attitudes towards the content of the consultation. Diverse preferences exist for what should be prioritised during vaccination consultations, and mismatched expectations may lead to negative experiences. Vaccination consultations for puppies and kittens were described to have a relatively standardised structure with an educational and preventative healthcare focus. In contrast, adult pet vaccination consultations were described to focus on current physical health problems with only limited discussion of preventative healthcare topics. This first qualitative exploration of UK vaccination consultation expectations suggests that the content and consistency of adult pet vaccination consultations may not meet the needs or expectations of all participants. Redefining preventative healthcare to include all preventable conditions may benefit owners, pets and veterinary surgeons, and may help to provide a clearer structure for adult pet vaccination consultations. This study represents a significant advance our understanding of this consultation type.

  13. WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

    International Nuclear Information System (INIS)

    Tsui, B.

    2016-01-01

    Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly

  14. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform.

    Science.gov (United States)

    Tryggestad, E; Armour, M; Iordachita, I; Verhaegen, F; Wong, J W

    2009-09-07

    Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP's treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min(-1) at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth-dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5-7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.

  15. PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner

    Science.gov (United States)

    Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2017-11-01

    MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.

  16. FID navigator-based MR thermometry method to monitor small temperature changes in the brain of ventilated animals.

    Science.gov (United States)

    Boulant, Nicolas; Bottlaender, Michel; Uhrig, Lynn; Giacomini, Eric; Luong, Michel; Amadon, Alexis; Massire, Aurélien; Larrat, Benoît; Vignaud, Alexandre

    2015-01-01

    An MR thermometry method is proposed for measuring in vivo small temperature changes engendered by external RF heat sources. The method relies on reproducible and stable respiration and therefore currently applies to ventilated animals whose breathing is carefully controlled. It first consists in characterizing the stability of the main magnetic field as well as the variations induced by breathing during a first monitoring stage. Second, RF heating is applied while the phase and thus temperature evolutions are continuously measured, the corrections due to breathing and field drift being made thanks to the data accumulated during the first period. The RF heat source is finally stopped and the temperature rise likewise is continuously monitored during a third and last stage to observe the animal cooling down and to validate the assumptions made for correcting for the main field variation and the physiological noise. Experiments were performed with a clinical 7 T scanner on an anesthetized baboon and with a dedicated RF heating setup. Analysis of the data reveals a precision around 0.1°C, which allows us to reliably measure sub-degree temperature rises in the muscle and in the brain of the animal. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Evaluating hypotheses of basal animal phylogeny using complete sequences of large and small subunit rRNA

    Energy Technology Data Exchange (ETDEWEB)

    Medina, Monica; Collins, Allen G.; Silberman, Jeffrey; Sogin, Mitchell L.

    2001-06-21

    We studied the evolutionary relationships among basal metazoan lineages by using complete large subunit (LSU) and small subunit (SSU) ribosomal RNA sequences for 23 taxa. After identifying competing hypotheses, we performed maximum likelihood searches for trees conforming to each hypothesis. Kishino-Hasegawa tests were used to determine whether the data (LSU, SSU, and combined) reject any of the competing hypotheses. We also conducted unconstrained tree searches, compared the resulting topologies, and calculated bootstrap indices. Shimodaira-Hasegawa tests were applied to determine whether the data reject any of the topologies resulting from the constrained and unconstrained tree searches. LSU, SSU, and the combined data strongly contradict two assertions pertaining to sponge phylogeny. Hexactinellid sponges are not likely to be the basal lineage of amonophyletic Porifera or the sister group to all other animals. Instead, Hexactinellida and Demospongia form a well-supported clade of siliceous sponges, Silicea. It remains unclear, on the basis of these data alone, whether the calcarean sponges are more closely related to Silicea or to nonsponge animals. The SSU and combined data reject the hypothesis that Bilateria is more closely related to Ctenophora than it is to Cnidaria, whereas LSU data alone do not refute either hypothesis. LSU and SSU data agree in supporting the monophyly of Bilateria, Cnidaria, Ctenophora, and Metazoa. LSU sequence data reveal phylogenetic structure in a data set with limited taxon sampling. Continued accumulation of LSU sequences should increase our understanding of animal phylogeny.

  18. Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Yang, Ching-Ching; Chan, Kai-Chieh

    2013-06-01

    -Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18 F radioactivity concentration of 1.86x10 5 Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The

  19. Assessment of bacterial contamination in the sectors of Clinical Medicine and Surgery Small Animal Veterinary Hospital, UFCG, PB

    Directory of Open Access Journals (Sweden)

    Rafaela Alves Dias

    2015-06-01

    Full Text Available ABSTRACT. Dias R.A., Souza A.P. & Garino Júnior F. [Assessment of bacterial contamination in the sectors of Clinical Medicine and Surgery Small Animal Veterinary Hospital, UFCG, PB.] Avaliação da contaminação bacteriana nos setores de Clínica e Cirurgia de Pequenos Animais do Hospital Veterinário da UFCG, PB. Revista Brasileira de Medicina Veterinária, 37(2:173-177, 2015. Programa de Pós-Graduação em Medicina Veterinária, Universidade Federal de Campina Grande, Av. Universitária, s/n, Bairro Santa Cecília, Patos, PB 58708-110, Brasil. E-mail: rafa.ad@hotmail.com With this study aimed to evaluate bacterial contamination sectors Clinic and Surgery Small Animal Veterinary Hospital UFCG, in order to prevent infections in patients attending hospital. An assessment of the environmental contamination of sectors before and after disinfection, where was collected samples of air, surfaces and hands of people who deal directly with the animals. Then the test was made of the effectiveness of disinfectants used. Of the 40 samples collected, was identified in 5 of them (12.5% Enterobacteria such as Escherichia coli and Klebisiella pneumoniae and in 22 samples (55% was identified Staphylococcus coagulase negative and positive. Was seen in the quantitative analysis that the number of cfu in some sample was above the indicated. The test showed that the disinfectant solution was effective against all micro-organisms found in the environments. The results indicate that more attention to procedures performed in the disinfection of areas evaluated, and also include measures to prevent contamination at these sites.

  20. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  1. Monitoring the Spatiotemporal Activities of miRNAs in Small Animal Models Using Molecular Imaging Modalities

    Directory of Open Access Journals (Sweden)

    Patrick Baril

    2015-03-01

    Full Text Available MicroRNAs (miRNAs are a class of small non-coding RNAs that regulate gene expression by binding mRNA targets via sequence complementary inducing translational repression and/or mRNA degradation. A current challenge in the field of miRNA biology is to understand the functionality of miRNAs under physiopathological conditions. Recent evidence indicates that miRNA expression is more complex than simple regulation at the transcriptional level. MiRNAs undergo complex post-transcriptional regulations such miRNA processing, editing, accumulation and re-cycling within P-bodies. They are dynamically regulated and have a well-orchestrated spatiotemporal localization pattern. Real-time and spatio-temporal analyses of miRNA expression are difficult to evaluate and often underestimated. Therefore, important information connecting miRNA expression and function can be lost. Conventional miRNA profiling methods such as Northern blot, real-time PCR, microarray, in situ hybridization and deep sequencing continue to contribute to our knowledge of miRNA biology. However, these methods can seldom shed light on the spatiotemporal organization and function of miRNAs in real-time. Non-invasive molecular imaging methods have the potential to address these issues and are thus attracting increasing attention. This paper reviews the state-of-the-art of methods used to detect miRNAs and discusses their contribution in the emerging field of miRNA biology and therapy.

  2. Preliminary study of metabolic radiotherapy with 188Re via small animal imaging

    International Nuclear Information System (INIS)

    Antoccia, A.; Baldazzi, G.; Bello, M.

    2006-01-01

    188 Re is a β - (Emax=2.12 MeV) and γ (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, 99m Tc, molecules of hyaluronic acid (HA) have been labelled with 188 Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm 3 pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of 188 Re and with C57 black mice injected with the 188 Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal projections simultaneously we are building in parallel two new cameras to be positioned at 90 degrees. They use a CsI(Tl) matrix with 1x1x5 mm 3 pixels read out by H8500 Hamamatsu Flat panel PMT

  3. Automatic cardiac gating of small-animal PET from list-mode data

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J.L.; Udias, J.M. [Universidad Complutense de Madrid Univ. (Spain). Grupo de Fisica Nuclear; Vaquero, J.J.; Desco, M. [Universidad Carlos III de Madrid (Spain). Dept. de Bioingenieria e Ingenieria Aeroespacial; Cusso, L. [Hospital General Universitario Gregorio Maranon, Madrid (Spain). Unidad de Medicina y Cirugia Experimental

    2011-07-01

    This work presents a method to obtain automatically the cardiac gating signal in a PET study of rats, by employing the variation with time of the counts in the cardiac region, that can be extracted from list-mode data. In an initial step, the cardiac region is identified in the image space by backward-projecting a small fraction of the acquired data and studying the variation with time of the counts in each voxel inside said region, with frequencies within 2 and 8 Hz. The region obtained corresponds accurately to the left-ventricle of the heart of the rat. In a second step, the lines-of-response (LORs) connected with this region are found by forward-projecting this region. The time variation of the number of counts in these LORs contains the cardiac motion information that we want to extract. This variation of counts with time is band-pass filtered to reduce noise, and the time signal so obtained is used to create the gating signal. The result was compared with a cardiac gating signal obtained from an ECG acquired simultaneously to the PET study. Reconstructed gated images obtained from both gating information are similar. The method proposed demonstrates that valid cardiac gating signals can be obtained for rats from PET list-mode data. (orig.)

  4. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Science.gov (United States)

    Harsha Maramraju, Sri; Smith, S. David; Junnarkar, Sachin S.; Schulz, Daniela; Stoll, Sean; Ravindranath, Bosky; Purschke, Martin L.; Rescia, Sergio; Southekal, Sudeepti; Pratte, Jean-François; Vaska, Paul; Woody, Craig L.; Schlyer, David J.

    2011-04-01

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 × 8 array of lutetium oxyorthosilicate crystals (2.22 × 2.22 × 5 mm3) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [11C]raclopride and 2-deoxy-2-[18F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  5. UCD-SPI: Un-Collimated Detector Single-Photon Imaging System for Small Animal and Plant Imaging

    Science.gov (United States)

    Walker, Katherine Leigh

    Medical imaging systems using single gamma-ray emitting radioisotopes implement collimators in order to form images. However, a tradeoff in sensitivity is inherent in the use of collimators, and modern preclinical single-photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma-rays (imaging, while still producing images of sufficient spatial resolution for certain applications in "thin" objects such as mice, small plants, and well plates used for in vitro experiments. This flexible geometry un-collimated detector single-photon imaging (UCD-SPI) system consists of two large (5 cm x 10 cm), thin (3 mm and 5 mm), closely spaced, pixelated scintillation detectors of either NaI(Tl), CsI(Na), or BGO. The detectors are read out by two adjacent Hamamatsu H8500 multichannel photomultiplier tubes. The detector heads enable the interchange of scintillation detectors of different materials and thicknesses to optimize performance for a wide range of gamma-ray energies and imaging subjects. The detectors are horizontally oriented for animal imaging, and for plant imaging the system is rotated on its side to orient the detectors vertically. While this un-collimated detector system is unable to approach the sub-mm spatial resolution obtained by the most advanced preclinical pinhole SPECT systems, the high sensitivity could enable significant and new use in molecular imaging applications which do not require good spatial resolution- for example, screening applications for drug development (small animals), for material transport and sequestration studies for phytoremediation (plants), or for counting radiolabeled cells in vitro (well plates).

  6. An optimized small animal tumour model for experimentation with low energy protons.

    Science.gov (United States)

    Beyreuther, Elke; Brüchner, Kerstin; Krause, Mechthild; Schmidt, Margret; Szabo, Rita; Pawelke, Jörg

    2017-01-01

    The long-term aim of developing laser based particle acceleration towards clinical application requires not only substantial technological progress, but also the radiobiological characterization of the resulting ultra-short and ultra-intensive particle beam pulses. After comprehensive cell studies a mouse ear tumour model was established allowing for the penetration of low energy protons (~20 MeV) currently available at laser driven accelerators. The model was successfully applied for a first tumour growth delay study with laser driven electrons, whereby the need of improvements crop out. To optimise the mouse ear tumour model with respect to a stable, high take rate and a lower number of secondary tumours, Matrigel was introduced for tumour cell injection. Different concentrations of two human tumour cell lines (FaDu, LN229) and Matrigel were evaluated for stable tumour growth and fulfilling the allocation criteria for irradiation experiments. The originally applied cell injection with PBS was performed for comparison and to assess the long-term stability of the model. Finally, the optimum suspension of cells and Matrigel was applied to determine applicable dose ranges for tumour growth delay studies by 200 kV X-ray irradiation. Both human tumour models showed a high take rate and exponential tumour growth starting at a volume of ~10 mm3. As disclosed by immunofluorescence analysis these small tumours already interact with the surrounding tissue and activate endothelial cells to form vessels. The formation of delimited, solid tumours at irradiation size was shown by standard H&E staining and a realistic dose range for inducing tumour growth delay without permanent tumour control was obtained for both tumour entities. The already established mouse ear tumour model was successfully upgraded now providing stable tumour growth with high take rate for two tumour entities (HNSCC, glioblastoma) that are of interest for future irradiation experiments at experimental

  7. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    Energy Technology Data Exchange (ETDEWEB)

    Efthimiou, Nikos [Technological Educational Institute of Athens (Greece); Kostou, Theodora; Papadimitroulas, Panagiotis [Technological Educational Institute of Athens (Greece); Department of Medical Physics, School of Medicine, University of Patras (Greece); Charalampos, Tsoumpas [Division of Biomedical Imaging, University of Leeds, Leeds (United Kingdom); Loudos, George [Technological Educational Institute of Athens (Greece)

    2015-05-18

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  8. An optimized small animal tumour model for experimentation with low energy protons.

    Directory of Open Access Journals (Sweden)

    Elke Beyreuther

    Full Text Available The long-term aim of developing laser based particle acceleration towards clinical application requires not only substantial technological progress, but also the radiobiological characterization of the resulting ultra-short and ultra-intensive particle beam pulses. After comprehensive cell studies a mouse ear tumour model was established allowing for the penetration of low energy protons (~20 MeV currently available at laser driven accelerators. The model was successfully applied for a first tumour growth delay study with laser driven electrons, whereby the need of improvements crop out.To optimise the mouse ear tumour model with respect to a stable, high take rate and a lower number of secondary tumours, Matrigel was introduced for tumour cell injection. Different concentrations of two human tumour cell lines (FaDu, LN229 and Matrigel were evaluated for stable tumour growth and fulfilling the allocation criteria for irradiation experiments. The originally applied cell injection with PBS was performed for comparison and to assess the long-term stability of the model. Finally, the optimum suspension of cells and Matrigel was applied to determine applicable dose ranges for tumour growth delay studies by 200 kV X-ray irradiation.Both human tumour models showed a high take rate and exponential tumour growth starting at a volume of ~10 mm3. As disclosed by immunofluorescence analysis these small tumours already interact with the surrounding tissue and activate endothelial cells to form vessels. The formation of delimited, solid tumours at irradiation size was shown by standard H&E staining and a realistic dose range for inducing tumour growth delay without permanent tumour control was obtained for both tumour entities.The already established mouse ear tumour model was successfully upgraded now providing stable tumour growth with high take rate for two tumour entities (HNSCC, glioblastoma that are of interest for future irradiation experiments at

  9. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    International Nuclear Information System (INIS)

    Efthimiou, Nikos; Kostou, Theodora; Papadimitroulas, Panagiotis; Charalampos, Tsoumpas; Loudos, George

    2015-01-01

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  10. In vivo imaging of dopamine transporter function in rat striatum using pinhole SPECT and 123I-beta-CIT coregistered with small animal MRI

    CERN Document Server

    Dierkes, K

    2001-01-01

    The aim of this study was to establish in vivo imaging of dopamine transporter function in a small animal model of Parkinson's disease using pinhole SPECT and 123I labeled beta-CIT. Since functional imaging of small animals can hardly be interpreted without localization to related anatomical structures, MRI-SPECT coregistration secondly was established as an inexpensive tool for in vivo monitoring of physiological and pathological alterations in striatal dopamine transporters using beta-CIT as an specific radionuclear ligand.

  11. Small animal PET imaging of HSV1-tk gene expression with {sup 124}IVDU in liver by the hydrodynamic injection

    Energy Technology Data Exchange (ETDEWEB)

    Song, I. H.; Lee, T. S.; Woo, S. G.; Jeong, J. H.; Kang, J. H.; Kim, K. M.; Chun, K. J.; Choi, C. W.; Lim, S. M. [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2007-07-01

    The liver is an important target organ for gene transfer due to its capacity for synthesizing serum protein and its involvement in numerous genetic diseases. High level of foreign gene expression in liver can be achieved by a large-volume and high-speed intravenous injection of naked plasmid DNA (pDNA), so called hydrodynamic injection. This study is aimed to evaluate liver specific-gene expression of herpes simplex virus type 1 thymidine kinase(HSV1-tk) by hydrodynamic injection and image HSV1-tk expression using {sup 124}IVDU-PET. We constructed herpes simplex virus type 1 thymidine kinase (HSV1-tk)-expressing pDNA (pHSV1-tk) modified from pEGFP-N1. Hydrodynamic injection was performed using 40 {mu}g of plasmid (pEGFP/N1 or pHSV1-tk) in 2 ml of 0.85% saline solution for 20{approx}22g mice in 5 seconds intravenously. At 1 d post-hydrodynamic injection, biodistribution study was performed at 2 h post-injection of radiolabeled IVDU, fluorescence image was obtained using optical imager and small animal PET image was acquired with {sup 124}IVDU at 2 h post-injection. After PET imaging, digital whole body autoradiography (DWBA) was performed. Expression of HSV1-tk and EGFP was confirmed by RT-PCR in each liver tissue. In liver of pHSV1-tk and pEGFP/N1 injection groups, {sup 123}IVDU uptake was 5.65%ID/g and 0.98%ID/g, respectively. {sup 123}IVDU uptake in liver of pHSV1-tk injection group showed 5.7-fold higher than that of pEGFP/N1 injection group (p<0.01). On the other hand, the liver of pEGFP/N1 injection group showed fluorescence activity. In small animal PET images, {sup 124}IVDU uptake was selectively localized in liver of pHSV1-tk injection group and also checked in DWBA, but showed minimal uptake in liver of pEGFP/N1 injection mice. Hydrodynamic injection was effective to liver-specific delivery of plasmid DNA. Small animal PET image of {sup 124}IVDU could be used in the evaluation of noninvasive reporter gene imaging in liver.

  12. A computational pipeline for quantification of pulmonary infections in small animal models using serial PET-CT imaging.

    Science.gov (United States)

    Bagci, Ulas; Foster, Brent; Miller-Jaster, Kirsten; Luna, Brian; Dey, Bappaditya; Bishai, William R; Jonsson, Colleen B; Jain, Sanjay; Mollura, Daniel J

    2013-07-23

    Infectious diseases are the second leading cause of death worldwide. In order to better understand and treat them, an accurate evaluation using multi-modal imaging techniques for anatomical and functional characterizations is needed. For non-invasive imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), there have been many engineering improvements that have significantly enhanced the resolution and contrast of the images, but there are still insufficient computational algorithms available for researchers to use when accurately quantifying imaging data from anatomical structures and functional biological processes. Since the development of such tools may potentially translate basic research into the clinic, this study focuses on the development of a quantitative and qualitative image analysis platform that provides a computational radiology perspective for pulmonary infections in small animal models. Specifically, we designed (a) a fast and robust automated and semi-automated image analysis platform and a quantification tool that can facilitate accurate diagnostic measurements of pulmonary lesions as well as volumetric measurements of anatomical structures, and incorporated (b) an image registration pipeline to our proposed framework for volumetric comparison of serial scans. This is an important investigational tool for small animal infectious disease models that can help advance researchers' understanding of infectious diseases. We tested the utility of our proposed methodology by using sequentially acquired CT and PET images of rabbit, ferret, and mouse models with respiratory infections of Mycobacterium tuberculosis (TB), H1N1 flu virus, and an aerosolized respiratory pathogen (necrotic TB) for a total of 92, 44, and 24 scans for the respective studies with half of the scans from CT and the other half from PET. Institutional Administrative Panel on Laboratory Animal Care approvals were

  13. Comparison between different methods for biomechanical assessment of ex vivo fracture callus stiffness in small animal bone healing studies.

    Directory of Open Access Journals (Sweden)

    Malte Steiner

    Full Text Available For ex vivo measurements of fracture callus stiffness in small animals, different test methods, such as torsion or bending tests, are established. Each method provides advantages and disadvantages, and it is still debated which of those is most sensitive to experimental conditions (i.e. specimen alignment, directional dependency, asymmetric behavior. The aim of this study was to experimentally compare six different testing methods regarding their robustness against experimental errors. Therefore, standardized specimens were created by selective laser sintering (SLS, mimicking size, directional behavior, and embedding variations of respective rat long bone specimens. For the latter, five different geometries were created which show shifted or tilted specimen alignments. The mechanical tests included three-point bending, four-point bending, cantilever bending, axial compression, constrained torsion, and unconstrained torsion. All three different bending tests showed the same principal behavior. They were highly dependent on the rotational direction of the maximum fracture callus expansion relative to the loading direction (creating experimental errors of more than 60%, however small angular deviations (<15° were negligible. Differences in the experimental results between the bending tests originate in their respective location of maximal bending moment induction. Compared to four-point bending, three-point bending is easier to apply on small rat and mouse bones under realistic testing conditions and yields robust measurements, provided low variation of the callus shape among the tested specimens. Axial compressive testing was highly sensitive to embedding variations, and therefore cannot be recommended. Although it is experimentally difficult to realize, unconstrained torsion testing was found to be the most robust method, since it was independent of both rotational alignment and embedding uncertainties. Constrained torsional testing showed small

  14. Evaluation of anesthesia effects on [18F]FDG uptake in mouse brain and heart using small animal PET

    International Nuclear Information System (INIS)

    Toyama, Hiroshi; Ichise, Masanori; Liow, Jeih-San; Vines, Douglass C.; Seneca, Nicholas M.; Modell, Kendra J.; Seidel, Jurgen; Green, Michael V.; Innis, Robert B.

    2004-01-01

    This study evaluates effects of anesthesia on 18 F-FDG (FDG) uptake in mouse brain and heart to establish the basic conditions of small animal PET imaging. Prior to FDG injection, 12 mice were anesthetized with isoflurane gas; 11 mice were anesthetized with an intraperitoneal injection of a ketamine/xylazine mixture; and 11 mice were awake. In isoflurane and ketamine/xylazine conditions, FDG brain uptake (%ID/g) was significantly lower than in controls. Conversely, in the isoflurane condition, %ID/g in heart was significantly higher than in controls, whereas heart uptake in ketamine/xylazine mice was significantly lower. Results suggest that anesthesia impedes FDG uptake in mouse brain and affects FDG uptake in heart; however, the effects in the brain and heart differ depending on the type of anesthesia used

  15. Performance study of a fan beam collimator designed for a multi-modality small animal imaging device

    International Nuclear Information System (INIS)

    Sabbir Ahmed, ASM; Kramer, Gary H.; Semmler, Wolfrad; Peter, Jorg

    2011-01-01

    This paper describes the methodology to design and conduct the performances of a fan beam collimator. This fan beam collimator was designed to use with a multi-modality small animal imaging device and the performance of the collimator was studied for a 3D geometry. Analytical expressions were formulated to calculate the parameters for the collimator. A Monte Carlo model was developed to analyze the scattering and image noises for a 3D object. The results showed that the performance of the fan beam collimator was strongly dependent on the source distribution and position. The fan beam collimator showed increased counting efficiency in comparison to a parallel hole collimator. Inside attenuating medium, the increased attenuating effect outweighed the fan beam increased counting efficiency.

  16. Evaluation of anesthesia effects on [{sup 18}F]FDG uptake in mouse brain and heart using small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Hiroshi E-mail: htoyama@fujita-hu.ac.jp; Ichise, Masanori; Liow, Jeih-San; Vines, Douglass C.; Seneca, Nicholas M.; Modell, Kendra J.; Seidel, Jurgen; Green, Michael V.; Innis, Robert B

    2004-02-01

    This study evaluates effects of anesthesia on {sup 18}F-FDG (FDG) uptake in mouse brain and heart to establish the basic conditions of small animal PET imaging. Prior to FDG injection, 12 mice were anesthetized with isoflurane gas; 11 mice were anesthetized with an intraperitoneal injection of a ketamine/xylazine mixture; and 11 mice were awake. In isoflurane and ketamine/xylazine conditions, FDG brain uptake (%ID/g) was significantly lower than in controls. Conversely, in the isoflurane condition, %ID/g in heart was significantly higher than in controls, whereas heart uptake in ketamine/xylazine mice was significantly lower. Results suggest that anesthesia impedes FDG uptake in mouse brain and affects FDG uptake in heart; however, the effects in the brain and heart differ depending on the type of anesthesia used.

  17. Evaluation of Timepix3 based CdTe photon counting detector for fully spectroscopic small animal SPECT imaging

    Science.gov (United States)

    Trojanova, E.; Jakubek, J.; Turecek, D.; Sykora, V.; Francova, P.; Kolarova, V.; Sefc, L.

    2018-01-01

    The imaging method of SPECT (Single Photon Emission Computed Tomography) is used in nuclear medicine for diagnostics of various diseases or organs malfunctions. The distribution of medically injected, inhaled, or ingested radionuclides (radiotracers) in the patient body is imaged using gamma-ray sensitive camera with suitable imaging collimator. The 3D image is then calculated by combining many images taken from different observation angles. Most of SPECT systems use scintillator based cameras. These cameras do not provide good energy resolution and do not allow efficient suppression of unwanted signals such as those caused by Compton scattering. The main goal of this work is evaluation of Timepix3 detector properties for SPECT method for functional imaging of small animals during preclinical studies. Advantageous Timepix3 properties such as energy and spatial resolution are exploited for significant image quality improvement. Preliminary measurements were performed on specially prepared plastic phantom with cavities filled by radioisotopes and then repeated with in vivo mouse sample.

  18. Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals.

    Science.gov (United States)

    Gateau, Jerome; Caballero, Miguel Angel Araque; Dima, Alexander; Ntziachristos, Vasilis

    2013-01-01

    Optoacoustic imaging relies on the detection of ultrasonic waves induced by laser pulse excitations to map optical absorption in biological tissue. A tomographic geometry employing a conventional ultrasound linear detector array for volumetric optoacoustic imaging is reported. The geometry is based on a translate-rotate scanning motion of the detector array, and capitalizes on the geometrical characteristics of the transducer assembly to provide a large solid angular detection aperture. A system for three-dimensional whole-body optoacoustic tomography of small animals is implemented. The detection geometry was tested using a 128-element linear array (5.0∕7.0 MHz, Acuson L7, Siemens), moved by steps with a rotation∕translation stage assembly. Translation and rotation range of 13.5 mm and 180°, respectively, were implemented. Optoacoustic emissions were induced in tissue-mimicking phantoms and ex vivo mice using a pulsed laser operating in the near-IR spectral range at 760 nm. Volumetric images were formed using a filtered backprojection algorithm. The resolution of the optoacoustic tomography system was measured to be better than 130 μm in-plane and 330 μm in elevation (full width half maximum), and to be homogenous along a 15 mm diameter cross section due to the translate-rotate scanning geometry. Whole-body volumetric optoacoustic images of mice were performed ex vivo, and imaged organs and blood vessels through the intact abdominal and head regions were correlated to the mouse anatomy. Overall, the feasibility of three-dimensional and high-resolution whole-body optoacoustic imaging of small animal using a conventional linear array was demonstrated. Furthermore, the scanning geometry may be used for other linear arrays and is therefore expected to be of great interest for optoacoustic tomography at macroscopic and mesoscopic scale. Specifically, conventional detector arrays with higher central frequencies may be investigated.

  19. Computer vision-based diameter maps to study fluoroscopic recordings of small intestinal motility from conscious experimental animals.

    Science.gov (United States)

    Ramírez, I; Pantrigo, J J; Montemayor, A S; López-Pérez, A E; Martín-Fontelles, M I; Brookes, S J H; Abalo, R

    2017-08-01

    When available, fluoroscopic recordings are a relatively cheap, non-invasive and technically straightforward way to study gastrointestinal motility. Spatiotemporal maps have been used to characterize motility of intestinal preparations in vitro, or in anesthetized animals in vivo. Here, a new automated computer-based method was used to construct spatiotemporal motility maps from fluoroscopic recordings obtained in conscious rats. Conscious, non-fasted, adult, male Wistar rats (n=8) received intragastric administration of barium contrast, and 1-2 hours later, when several loops of the small intestine were well-defined, a 2 minutes-fluoroscopic recording was obtained. Spatiotemporal diameter maps (Dmaps) were automatically calculated from the recordings. Three recordings were also manually analyzed for comparison. Frequency analysis was performed in order to calculate relevant motility parameters. In each conscious rat, a stable recording (17-20 seconds) was analyzed. The Dmaps manually and automatically obtained from the same recording were comparable, but the automated process was faster and provided higher resolution. Two frequencies of motor activity dominated; lower frequency contractions (15.2±0.9 cpm) had an amplitude approximately five times greater than higher frequency events (32.8±0.7 cpm). The automated method developed here needed little investigator input, provided high-resolution results with short computing times, and automatically compensated for breathing and other small movements, allowing recordings to be made without anesthesia. Although slow and/or infrequent events could not be detected in the short recording periods analyzed to date (17-20 seconds), this novel system enhances the analysis of in vivo motility in conscious animals. © 2017 John Wiley & Sons Ltd.

  20. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging

    Science.gov (United States)

    Lee, Sang Chul; Kim, Ho Kyung; Chun, In Kon; Hye Cho, Myung; Lee, Soo Yeol; Cho, Min Hyoung

    2003-12-01

    A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 × 120 mm2, a microfocus x-ray source, a rotational subject holder and a parallel data processing system. The flat-panel detector is based on a matrix-addressed photodiode array fabricated by a CMOS (complementary metal-oxide semiconductor) process coupled to a CsI:Tl (thallium-doped caesium iodide) scintillator as an x-ray-to-light converter. Principal imaging performances of the micro-CT system have been evaluated in terms of image uniformity, voxel noise and spatial resolution. It has been found that the image non-uniformity mainly comes from the structural non-uniform sensitivity pattern of the flat-panel detector and the voxel noise is about 48 CT numbers at the voxel size of 100 × 100 × 200 µm3 and the air kerma of 286 mGy. When the magnification ratio is 2, the spatial resolution of the micro-CT system is about 14 lp/mm (line pairs per millimetre) that is almost determined by the flat-panel detector showing about 7 lp/mm resolving power. Through low-contrast phantom imaging studies, the minimum resolvable contrast has been found to be less than 36 CT numbers at the air kerma of 95 mGy. Some laboratory rat imaging results are presented.

  1. Design of an advanced positron emission tomography detector system and algorithms for imaging small animal models of human disease

    Science.gov (United States)

    Foudray, Angela Marie Klohs

    Detecting, quantifying and visualizing biochemical mechanism in a living system without perturbing function is the goal of the instrument and algorithms designed in this thesis. Biochemical mechanisms of cells have long been known to be dependent on the signals they receive from their environment. Studying biological processes of cells in-vitro can vastly distort their function, since you are removing them from their natural chemical signaling environment. Mice have become the biological system of choice for various areas of biomedical research due to their genetic and physiological similarities with humans, the relatively low cost of their care, and their quick breeding cycle. Drug development and efficacy assessment along with disease detection, management, and mechanism research all have benefited from the use of small animal models of human disease. A high resolution, high sensitivity, three-dimensional (3D) positioning positron emission tomography (PET) detector system was designed through device characterization and Monte Carlo simulation. Position-sensitive avalanche photodiodes (PSAPDs) were characterized in various packaging configurations; coupled to various configurations of lutetium oxyorthosilicate (LSO) scintillation crystals. Forty novelly packaged final design devices were constructed and characterized, each providing characteristics superior to commercially available scintillation detectors used in small animal imaging systems: ˜1mm crystal identification, 14-15% of 511 keV energy resolution, and averaging 1.9 to 5.6 ns coincidence time resolution. A closed-cornered box-shaped detector configuration was found to provide optimal photon sensitivity (˜10.5% in the central plane) using dual LSO-PSAPD scintillation detector modules and Monte Carlo simulation. Standard figures of merit were used to determine optimal system acquisition parameters. A realistic model for constituent devices was developed for understanding the signals reported by the

  2. Computerized detection and analysis of cancer chemotherapy-induced emesis in a small animal model, musk shrew.

    Science.gov (United States)

    Huang, Dong; Meyers, Kelly; Henry, Séverine; De la Torre, Fernando; Horn, Charles C

    2011-04-30

    Vomiting is a common side effect of cancer chemotherapy and many drug treatments and diseases. In animal studies, the measurement of vomiting usually requires direct observation, which is time consuming and often lacks temporal precision. Musk shrews have been used to study the neurobiology of emesis and have a rapid emetic episode (∼1 s for a sequence of retching and expulsion). The aim of the current study was to develop a method to automatically detect and characterize emetic episodes induced by the cancer chemotherapy agent cisplatin. The body contour in each video frame was tracked and normalized to a parameterized shape basis. The tracked shape was projected to a feature space that maximized the shape variations in the consecutive frames during retching. The resulting one dimensional projection was sufficient to detect most emetic episodes in the acute (peak at 2h) and delayed (peak at 54 h) phases after cisplatin treatment. Emetic episodes were relatively invariant in the number of retches (∼6.2), duration (∼1.2s), inter-retch interval (∼198 ms), and amplitude during the 72 h after cisplatin treatment. This approach should open a new vista into emesis research to permit tracking and analysis of emesis in a small animal model and facilitate the development of new antiemetic therapies. These results also yield a better understanding of the brain's central pattern generator for emesis and indicate that the retching response in the musk shrew (at ∼5.4 Hz) is the fastest ever recorded in a free-moving animal. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Hardware, software, and scanning issues encountered during small animal imaging of photodynamic therapy in the athymic nude rat

    Science.gov (United States)

    Cross, Nathan; Sharma, Rahul; Varghai, Davood; Spring-Robinson, Chandra; Oleinick, Nancy L.; Muzic, Raymond F., Jr.; Dean, David

    2007-02-01

    Small animal imaging devices are now commonly used to study gene activation and model the effects of potential therapies. We are attempting to develop a protocol that non-invasively tracks the affect of Pc 4-mediated photodynamic therapy (PDT) in a human glioma model using structural image data from micro-CT and/or micro-MR scanning and functional data from 18F-fluorodeoxy-glucose (18F-FDG) micro-PET imaging. Methods: Athymic nude rat U87-derived glioma was imaged by micro-PET and either micro-CT or micro-MR prior to Pc 4-PDT. Difficulty insuring animal anesthesia and anatomic position during the micro-PET, micro-CT, and micro-MR scans required adaptation of the scanning bed hardware. Following Pc 4-PDT the animals were again 18F-FDG micro-PET scanned, euthanized one day later, and their brains were explanted and prepared for H&E histology. Histology provided the gold standard for tumor location and necrosis. The tumor and surrounding brain functional and structural image data were then isolated and coregistered. Results: Surprisingly, both the non-PDT and PDT groups showed an increase in tumor functional activity when we expected this signal to disappear in the group receiving PDT. Co-registration of the functional and structural image data was done manually. Discussion: As expected, micro-MR imaging provided better structural discrimination of the brain tumor than micro-CT. Contrary to expectations, in our preliminary analysis 18F-FDG micro-PET imaging does not readily discriminate the U87 tumors that received Pc 4-PDT. We continue to investigate the utility of micro-PET and other methods of functional imaging to remotely detect the specificity and sensitivity of Pc 4-PDT in deeply placed tumors.

  4. Small animal magnetic resonance imaging: an efficient tool to assess liver volume and intrahepatic vascular anatomy.

    Science.gov (United States)

    Melloul, Emmanuel; Raptis, Dimitri A; Boss, Andreas; Pfammater, Thomas; Tschuor, Christoph; Tian, Yinghua; Graf, Rolf; Clavien, Pierre-Alain; Lesurtel, Mickael

    2014-04-01

    To develop a noninvasive technique to assess liver volumetry and intrahepatic portal vein anatomy in a mouse model of liver regeneration. Fifty-two C57BL/6 male mice underwent magnetic resonance imaging (MRI) of the liver using a 4.7 T small animal MRI system after no treatment, 70% partial hepatectomy (PH), or selective portal vein embolization. The protocol consisted of the following sequences: three-dimensional-encoded spoiled gradient-echo sequence (repetition time per echo time 15 per 2.7 ms, flip angle 20°) for volumetry, and two-dimensional-encoded time-of-flight angiography sequence (repetition time per echo time 18 per 6.4 ms, flip angle 80°) for vessel visualization. Liver volume and portal vein segmentation was performed using a dedicated postprocessing software. In animals with portal vein embolization, portography served as reference standard. True liver volume was measured after sacrificing the animals. Measurements were carried out by two independent observers with subsequent analysis by the Cohen κ-test for interobserver agreement. MRI liver volumetry highly correlated with the true liver volume measurement using a conventional method in both the untreated liver and the liver remnant after 70% PH with a high interobserver correlation coefficient of 0.94 (95% confidence interval, 0.80-0.98 for untreated liver [P anatomy was excellent (Cohen κ value = 0.925). This protocol may be used for noninvasive liver volumetry and visualization of portal vein anatomy in mice. It will serve the dynamic study of new strategies to enhance liver regeneration in vivo. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Study and development of a high resolution tomograph for the γ radio-imagery in vivo of small animals

    International Nuclear Information System (INIS)

    Valda Ochoa, A.

    1995-01-01

    By the use of molecular radio-labelled tracers, molecular biology can reveal some aspects of the functional organisation of the brain. Non invasive in vivo brain research on small laboratory animals, like mice or rats, require analysis of structures of some cubic millimeters present in a brain of the order of a cubic centimeter. Since imaging performances of positron emission tomography (PET) and single photon emission tomography (SPECT) fail in this research field, we present here a high resolution tomograph (TOHR) based on an original principle that allows to overcome the compromise between detection efficiency and spatial resolution. TOHR is a radiation counter device having a large solid angle focusing collimator. By the use of radio-tracers decaying by a cascade of two photons, coincidence detection offers an accurate delimitation of the analysed region and improves spatial resolution. TOHR acts as a scanner, so the image is built voxel by voxel by moving the animal relative to the detector. A numerical feasibility study of such a system shows that a sub millimeter spatial resolution can be achieved. We show that the chemical etching technique is well suited for manufacturing a multi-module focusing collimator by building and testing two such modules. Finally a numerical simulation exhibits TOHR's performance in a neuro-pharmacological experiment on a rat. From these results, other application of TOHR are envisaged, such as oncology (in vivo evolution of tumours) or gene therapy (distribution of viral particles in the brain). (author). 51 refs., 73 figs., 3 tabs

  6. Longitudinal Raman Spectroscopic Observation of Skin Biochemical Changes due to Chemotherapeutic Treatment for Breast Cancer in Small Animal Model

    Directory of Open Access Journals (Sweden)

    Myeongsu Seong

    2017-01-01

    Full Text Available The cancer field effect (CFE has been highlighted as one of indirect indications for tissue variations that are insensitive to conventional diagnostic techniques. In this research, we had a hypothesis that chemotherapy for breast cancer would affect skin biochemical compositions that would be reflected by Raman spectral changes. We used a fiber-optic probe-based Raman spectroscopy to perform preliminary animal experiments to validate the hypothesis. Firstly, we verified the probing depth of the fiber-optic probe (~800 μm using a simple intravenous fat emulsion-filled phantom having a silicon wafer at the bottom inside a cuvette. Then, we obtained Raman spectra during breast cancer treatment by chemotherapy from a small animal model in longitudinal manner. Our results showed that the treatment causes variations of biochemical compositions in the skin. For further validation, the Raman spectra will have to be collected from more populations and spectra will need to be compared with immunohistochemistry of the breast tissue.

  7. Anatomical and metabolic small-animal whole-body imaging using ring-shaped confocal photoacoustic computed tomography

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad; Maslov, Konstantin; Wang, Lihong V.

    2013-03-01

    Due to the wide use of animals for human disease studies, small animal whole-body imaging plays an increasingly important role in biomedical research. Currently, none of the existing imaging modalities can provide both anatomical and glucose metabolic information, leading to higher costs of building dual-modality systems. Even with image coregistration, the spatial resolution of the metabolic imaging modality is not improved. We present a ring-shaped confocal photoacoustic computed tomography (RC-PACT) system that can provide both assessments in a single modality. Utilizing the novel design of confocal full-ring light delivery and ultrasound transducer array detection, RC-PACT provides full-view cross-sectional imaging with high spatial resolution. Scanning along the orthogonal direction provides three-dimensional imaging. While the mouse anatomy was imaged with endogenous hemoglobin contrast, the glucose metabolism was imaged with a near-infrared dye-labeled 2-deoxyglucose. Through mouse tumor models, we demonstrate that RC-PACT may be a paradigm shifting imaging method for preclinical research.

  8. Inhalation toxicology. I., Design of a small-animal test system, II. Determination of the relative toxic hazards of 75 aircraft cabin materials.

    Science.gov (United States)

    1977-01-01

    In an effort to further the cause of increased safety for those who ride in commercial aircraft, this paper presents a detailed description of the genesis of a small-scale, laboratory test system that utilizes small animals to evaluate the relative t...

  9. Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: in vivo small animal study

    Science.gov (United States)

    Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui

    2011-03-01

    Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.

  10. Antibiotic Resistance in Animal and Environmental Samples Associated with Small-Scale Poultry Farming in Northwestern Ecuador.

    Science.gov (United States)

    Braykov, Nikolay P; Eisenberg, Joseph N S; Grossman, Marissa; Zhang, Lixin; Vasco, Karla; Cevallos, William; Muñoz, Diana; Acevedo, Andrés; Moser, Kara A; Marrs, Carl F; Foxman, Betsy; Trostle, James; Trueba, Gabriel; Levy, Karen

    2016-01-01

    The effects of animal agriculture on the spread of antibiotic resistance (AR) are cross-cutting and thus require a multidisciplinary perspective. Here we use ecological, epidemiological, and ethnographic methods to examine populations of Escherichia coli circulating in the production poultry farming environment versus the domestic environment in rural Ecuador, where small-scale poultry production employing nontherapeutic antibiotics is increasingly common. We sampled 262 "production birds" (commercially raised broiler chickens and laying hens) and 455 "household birds" (raised for domestic use) and household and coop environmental samples from 17 villages between 2010 and 2013. We analyzed data on zones of inhibition from Kirby-Bauer tests, rather than established clinical breakpoints for AR, to distinguish between populations of organisms. We saw significantly higher levels of AR in bacteria from production versus household birds; resistance to either amoxicillin-clavulanate, cephalothin, cefotaxime, and gentamicin was found in 52.8% of production bird isolates and 16% of household ones. A strain jointly resistant to the 4 drugs was exclusive to a subset of isolates from production birds (7.6%) and coop surfaces (6.5%) and was associated with a particular purchase site. The prevalence of AR in production birds declined with bird age (P < 0.01 for all antibiotics tested except tetracycline, sulfisoxazole, and trimethoprim-sulfamethoxazole). Farming status did not impact AR in domestic environments at the household or village level. Our results suggest that AR associated with small-scale poultry farming is present in the immediate production environment and likely originates from sources outside the study area. These outside sources might be a better place to target control efforts than local management practices. IMPORTANCE In developing countries, small-scale poultry farming employing antibiotics as growth promoters is being advanced as an inexpensive source of

  11. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    International Nuclear Information System (INIS)

    Kim, Haksoo; Welford, Scott; Fabien, Jeffrey; Zheng, Yiran; Yuan, Jake; Brindle, James; Yao, Min; Lo, Simon; Wessels, Barry; Machtay, Mitchell; Sohn, Jason W.; Sloan, Andrew

    2014-01-01

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A

  12. The Combination of In vivo (124)I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry.

    Science.gov (United States)

    El-Ali, Henrik H; Eckerwall, Martin; Skovgaard, Dorthe; Larsson, Erik; Strand, Sven-Erik; Kjaer, Andreas

    2012-06-05

    A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that (124)I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Seven rats were subjects for multiple thyroid (124)I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34-70 mL. The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

  13. The Combination of In vivo 124I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry

    Directory of Open Access Journals (Sweden)

    Henrik H. El-Ali

    2012-06-01

    Full Text Available Objective: A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that 124I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Methods: Seven rats were subjects for multiple thyroid 124I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Results: Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34–70 mL. Conclusions: The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

  14. Non-invasive imaging of acute renal allograft rejection in rats using small animal F-FDG-PET.

    Directory of Open Access Journals (Sweden)

    Stefan Reuter

    Full Text Available BACKGROUND: At present, renal grafts are the most common solid organ transplants world-wide. Given the importance of renal transplantation and the limitation of available donor kidneys, detailed analysis of factors that affect transplant survival are important. Despite the introduction of new and effective immunosuppressive drugs, acute cellular graft rejection (AR is still a major risk for graft survival. Nowadays, AR can only be definitively by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Most important, they can not be performed in patients taking anticoagulant drugs. METHODOLOGY/PRINCIPAL FINDINGS: We present a non-invasive, entirely image-based method to assess AR in an allogeneic rat renal transplantation model using small animal positron emission tomography (PET and (18F-fluorodeoxyglucose (FDG. 3 h after i.v. injection of 30 MBq FDG into adult uni-nephrectomized, allogeneically transplanted rats, tissue radioactivity of renal parenchyma was assessed in vivo by a small animal PET-scanner (post operative day (POD 1,2,4, and 7 and post mortem dissection. The mean radioactivity (cps/mm(3 tissue as well as the percent injected dose (%ID was compared between graft and native reference kidney. Results were confirmed by histological and autoradiographic analysis. Healthy rats, rats with acute CSA nephrotoxicity, with acute tubular necrosis, and syngeneically transplanted rats served as controls. FDG-uptake was significantly elevated only in allogeneic grafts from POD 1 on when compared to the native kidney (%ID graft POD 1: 0.54+/-0.06; POD 2: 0.58+/-0.12; POD 4: 0.81+/-0.06; POD 7: 0.77+/-0.1; CTR: 0.22+/-0.01, n = 3-28. Renal FDG-uptake in vivo correlated with the results obtained by micro-autoradiography and the degree of inflammatory infiltrates observed in histology. CONCLUSIONS/SIGNIFICANCE: We propose that graft FDG-PET imaging is a new option to non-invasively, specifically, early detect, and follow

  15. SemiSPECT: A small-animal SPECT imager based on eight cadmium zinc tellurium detector arrays

    Science.gov (United States)

    Kim, Hyunki

    We have completed a new small-animal imaging system, called SemiSPECT, based on eight pixellated cadmium zinc telluride (CdZnTe) gamma-ray detector arrays. The detector is a 2.5 cm x 2.5 cm x 0.15 cm slab having a 64 x 64 pixel array. A read-out application-specific integrated circuit (ASIC) is attached onto the detector via indium-bump bonding, and a -180 V bias is applied onto the detector surface to transport electron-hole pairs generated by gamma-ray interaction. Eight detectors are arranged in an octagonal lead-shielded ring. An eight-pinhole aperture is placed at the center of the ring, and an object is imaged onto each detector through a pinhole. The object can be rotated about a vertical axis to attain sufficient angular projections for tomographic reconstruction. The whole system gantry is compact enough to be placed onto a desktop-sized optical breadboard. Eight front-end boards were developed to detect events, generate list-mode data arrays, and send them to back-end boards. Four back-end boards are utilized to hold the list-mode data arrays and transfer them to a host computer. Eight clock-and-bias boards provide clock and bias signals to the eight ASICs. Eight control-and-bias boards were developed to monitor and control the temperatures on the eight detectors, analog and digital currents supplied to the eight ASICs, and -180 V biases applied to the eight detector surfaces. The spatial resolution provided by SemiSPECT, estimated both based on the system geometry and via the Fourier crosstalk approach, is about 1˜2 mm. The system sensitivity measured with a point source is about 1.53 x 10-4, and the estimated one from the system geometry is about 1.41 x 10-4. The energy resolution acquired by summing neighboring pixel signals in a 3 x 3 window is about 10% full-width-at-half-maximum for 140 keV gamma rays. The detectabilities for multiple signal spheres simulating various lesions or organs in a small animal are presented and discussed. A line

  16. Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla.

    Science.gov (United States)

    Stortz, Greg; Thiessen, Jonathan D; Bishop, Daryl; Khan, Muhammad Salman; Kozlowski, Piotr; Retière, Fabrice; Schellenberg, Graham; Shams, Ehsan; Zhang, Xuezhu; Thompson, Christopher J; Goertzen, Andrew L; Sossi, Vesna

    2018-03-01

    We characterize a compact MR-compatible PET insert for simultaneous preclinical PET/MRI. Although specifically designed with the strict size constraint to fit inside the 114-mm inner diameter of the BGA-12S gradient coil used in the BioSpec 70/20 and 94/20 series of small-animal MRI systems, the insert can easily be installed in any appropriate MRI scanner or used as a stand-alone PET system. Methods: The insert consists of a ring of 16 detector-blocks each made from depth-of-interaction-capable dual-layer-offset arrays of cerium-doped lutetium-yttrium oxyorthosilicate crystals read out by silicon photomultiplier arrays. Scintillator crystal arrays are made from 22 × 10 and 21 × 9 crystals in the bottom and top layers, respectively, with respective layer thicknesses of 6 and 4 mm, arranged with a 1.27-mm pitch, resulting in a useable field of view 28 mm long and about 55 mm wide. Results: Spatial resolution ranged from 1.17 to 1.86 mm full width at half maximum in the radial direction from a radial offset of 0-15 mm. With a 300- to 800-keV energy window, peak sensitivity was 2.2% and noise-equivalent count rate from a mouse-sized phantom at 3.7 MBq was 11.1 kcps and peaked at 20.8 kcps at 14.5 MBq. Phantom imaging showed that features as small as 0.7 mm could be resolved. 18 F-FDG PET/MR images of mouse and rat brains showed no signs of intermodality interference and could excellently resolve substructures within the brain. Conclusion: Because of excellent spatial resolvability and lack of intermodality interference, this PET insert will serve as a useful tool for preclinical PET/MR. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Animal models

    DEFF Research Database (Denmark)

    Gøtze, Jens Peter; Krentz, Andrew

    2014-01-01

    In this issue of Cardiovascular Endocrinology, we are proud to present a broad and dedicated spectrum of reviews on animal models in cardiovascular disease. The reviews cover most aspects of animal models in science from basic differences and similarities between small animals and the human...

  18. Development of a New Positron Emission Tomography Tracer for Targeting Tumor Angiogenesis: Synthesis, Small Animal Imaging, and Radiation Dosimetry

    Directory of Open Access Journals (Sweden)

    David S. Lalush

    2013-05-01

    Full Text Available Angiogenesis plays a key role in cancer progression and correlates with disease aggressiveness and poor clinical outcomes. Affinity ligands discovered by screening phage display random peptide libraries can be engineered to molecularly target tumor blood vessels for noninvasive imaging and early detection of tumor aggressiveness. In this study, we tested the ability of a phage-display-selected peptide sequence recognizing specifically bone marrow- derived pro-angiogenic tumor-homing cells, the QFP-peptide, radiolabeled with 64Cu radioisotope to selectively image tumor vasculature in vivo by positron emission tomography (PET. To prepare the targeted PET tracer we modified QFP-phage with the DOTA chelator and radiolabeled the purified QFP-phage-DOTA intermediate with 64Cu to obtain QFP-targeted radioconjugate with high radiopharmaceutical yield and specific activity. We evaluated the new PET tracer in vivo in a subcutaneous (s.c. Lewis lung carcinoma (LLC mouse model and conducted tissue distribution, small animal PET/CT imaging study, autoradiography, histology, fluorescence imaging, and dosimetry assessments. The results from this study show that, in the context of the s.c. LLC immunocompetent mouse model, the QFP-tracer can target tumor blood vessels selectively. However, further optimization of the biodistribution and dosimetry profile of the tracer is necessary to ensure efficient radiopharmaceutical applications enabled by the biological specificity of the QFP-peptide.

  19. Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination

    International Nuclear Information System (INIS)

    Da Silva, Anabela; Leabad, Mehdi; Driol, Clemence; Bordy, Thomas; Debourdeau, Mathieu; Dinten, Jean-Marc; Peltie, Philippe; Rizo, Philippe

    2009-01-01

    A small-animal multimodality tomography system dedicated to the coregistration of fluorescence optical signal and x-ray measurements has been developed in our laboratory. The purpose of such a system is to offer the possibility of getting in vivo anatomical and functional information simultaneously. Moreover, anatomical measurements can be used as a regularization factor to achieve more accurate reconstructions of the biodistribution of fluorochromes and to speed up treatment. A dedicated acquisition protocol has been established, and the methodology of the reconstruction of the three-dimensional distribution of the biomarkers under cylindrical geometry consistent with classic computed tomography has been implemented. A phantom study was conducted to evaluate and to fix the parameters for the coregistration. These test experiments were reproduced by considering anesthetized mice that had thin glass tubes containing fluorochromes inserted into their esophagus. The instrument is also used for an in vivo biological study conducted on mice with lung tumors, tagged with near-infrared optical probes (targeting probes such as Transferin-AlexaFluor750)

  20. WRN conditioned media is sufficient for in vitro propagation of intestinal organoids from large farm and small companion animals

    Directory of Open Access Journals (Sweden)

    Robin H. Powell

    2017-05-01

    Full Text Available Recent years have seen significant developments in the ability to continuously propagate organoids derived from intestinal crypts. These advancements have been applied to mouse and human samples providing models for gastrointestinal tissue development and disease. We adapt these methods for the propagation of intestinal organoids (enteroids from various large farm and small companion (LF/SC animals, including cat, dog, cow, horse, pig, sheep and chicken. We show that LF/SC enteroids propagate and expand in L-WRN conditioned media containing signaling factors Wnt3a, R-spondin-3, and Noggin (WRN. Multiple successful isolations were achieved for each species, and the growth of LF/SC enteroids was maintained to high passage number. LF/SC enteroids expressed crypt stem cell marker LGR5 and low levels of mesenchymal marker VIM. Labeling with EdU also showed distinct regions of cell proliferation within the enteroids marking crypt-like regions. The ability to grow and maintain LF/SC enteroid cell lines provides additional models for the study of gastrointestinal developmental biology as well as platforms for the study of host-pathogen interactions between intestinal cells and zoonotic enteric pathogens of medical importance.

  1. Coincidence measurements on detectors for microPET II: A 1 mm3 resolution PET scanner for small animal imaging

    CERN Document Server

    Chatziioannou, A; Shao, Y; Doshi, N K; Silverman, B; Meadors, K; Cherry, SR

    2000-01-01

    We are currently developing a small animal PET scanner with a design goal of 1 mm3 image resolution. We have built three pairs of detectors and tested performance in terms of crystal identification, spatial, energy and timing resolution. The detectors consisted of 12 multiplied by 12 arrays of 1 multiplied by 1 multiplied by 10mm LSO crystals (1.15 mm pitch) coupled to Hamamatsu H7546 64 channel PMTs via 5cm long coherent glass fiber bundles. Optical fiber connection is necessary to allow high packing fraction in a ring geometry scanner. Fiber bundles with and without extramural absorber (EMA) were tested. The results demonstrated an intrinsic spatial resolution of 1.12 mm (direct coupled LSO array), 1.23 mm (bundle without EMA) and 1.27 mm (bundle with EMA) using a similar to 500 micron diameter Na-22 source. Using a 330 micron line source filled with F-18, intrinsic resolution for the EMA bundle improved to 1.05 mm. The respective timing and energy resolution values were 1.96 ns, 21% (direct coupled), 2.20 ...

  2. 3D absorbed dose calculation with GATE Monte Carlo simulation for the image-guided radiation therapy dedicated to the small animal

    International Nuclear Information System (INIS)

    Noblet, Caroline

    2014-01-01

    Innovating irradiators dedicated to small animal allow to mimic clinical treatments in image-guided radiation therapy. Clinical practice is scaled down to the small animal by reducing beam dimensions (from cm to mm) and energy (from MeV to keV). Millimeter medium energy beams (<300 keV) are used to treat animals. This scaling induces higher constraints than in clinical practice especially for absorbed dose calculation in animals. Due to the beam dimensions and the medium energy range, clinical dose calculation methods are not easily applicable to the preclinical practice. Monte Carlo methods are needed. To this aim, a Monte Carlo model of the XRAD225Cx preclinical irradiator has been developed with the GATE (Geant4) framework. This model was validated by comparing simulation results against measurements and results obtained with a reference Monte Carlo code in external beam radiation therapy, EGSnrc. A specific issue has been highlighted: the significant dosimetric impact of tissue segmentation in the animal CT images. Indeed, at medium energy range, thresholding based on electronic density cannot accurately take into account the heterogeneities. Materials should be defined using both the tissue elemental composition and the mass density. An original segmentation method has been developed to obtain realistic dose distributions in small animals. Finally, our Monte Carlo platform has been successfully used for several radiobiological studies with mice and rats. (author) [fr

  3. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals

    International Nuclear Information System (INIS)

    Arthur, Paula Bergamin

    2012-01-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 ± 2 Deg C and relative humidity of 70 ± 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  4. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    Science.gov (United States)

    Anvari, Akbar; Poirier, Yannick; Sawant, Amit

    2018-04-28

    Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibility of SA-IGRT systems. Several investigators have reported custom-made phantoms and protocols for SA-IGRT systems QA. These are typically time and resource intensive and are therefore not well suited to the preclinical radiotherapy environment, in which physics support is limited and routine QA is performed by technical staff. We investigated the use of the in-built electronic portal imaging device (EPID) to develop and validate routine QA tests and procedures. In this work, we focus on the XSTRAHL Small Animal Radiation Research Platform (SARRP) EPID. However, the methodology and tests developed here are applicable to any SA-IGRT system that incorporates an EPID. We performed a comprehensive characterization of the dosimetric properties of the camera-based EPID at kilovoltage energies over an 11-month period, including detector warm-up time, radiation dose history effect, stability and short- and long-term reproducibility, gantry angle dependency, output factor, and linearity of the EPID response. We developed a test to measure the constancy of beam quality in terms of half-value layer and tube peak potential using the EPID. We verified the SARRP daily output and beam profile constancy using the imager. We investigated the use of the imager to monitor beam targeting accuracy at various gantry and couch angles. The EPID response was stable and reproducible, exhibiting maximum variations of ≤0.3% and ≤1.9% for short and long terms, respectively. The detector showed no dependence on response at different gantry angles, with a maximum variation of ≤0.5%. We found close agreement in output factor measurement between the portal imager and reference

  5. Euthanasia in small animals in Teresina – PI/ Eutanásia em pequenos animais em Teresina – PI

    Directory of Open Access Journals (Sweden)

    Ezequiel Cardoso Saraiva de Almeida

    2005-06-01

    Full Text Available Euthanasia is a procedure frequently utilized in small animals with the objective to minimize suffering. In this way, it was realized the survey about reasons that leave the practitioner to realize the procedure and who are these animals. It was analyzed 17406 medical records. It was observed 166 euthanasia corresponding to 0.95%. The percentage of the euthanazied dogs were 97.59% and 2.41% felines. In relation to breed 26.10% were mongrel dogs, 20.48% German sheepherd, 9.04% Brazilian fila, 7.23% Pekinese and 36.75% other breeds. In relation to age, it was observed that 60.84% have 0 – 3 year, 15.06% 3 – 6 year, 4.82% 6 – 9 year, 4.22% 9 – 12 year, 1.2% above 12 year and 13.86% unknown age. About the reason of the euthanasia, 64.60% was sacrificed due to visceral leishmaniosis (calazar, 12.65% due to distemper and 22.89% due to other diseases. It was concluded that the most animals submitted to euthanasia were young, differently of the other countries. Among principal death reasons, it was included also infectious diseases that can be prevented by adequate vaccination.A eutanásia é um procedimento utilizado com freqüência em pequenos animais, com o objetivo principal de aliviar o sofrimento. Desta forma, realizou-se um levantamento sobre os motivos que levam um veterinário a indicá-la e quais são estes animais. Foram analisadas 17406 fichas, onde se observaram 166 eutanásias o que corresponde a 0,95%. A percentagem de cães eutanasiados foi de 97,59% e a de felinos 2,41%. Em relação à raça, 26,10% dos animais era sem raça definida, 20,48% pastor alemão, 9,04% fila brasileiro, 7,23% pequinês e 36, 75% outras raças. Com respeito à idade, registrou-se que 60,84% tinham entre 0 e 3 anos, 15,06% 3 e 6 anos, 4,82% 6 e 9 anos, 4,22% 9 e 12 anos, 1,20% acima de 12 anos e 13,86% idade desconhecida. Sobre o motivo da eutanásia, 64,60% dos animais foram eutanasiados devido à Leishmaniose Visceral Canina (calazar, 12,65% devido a

  6. Ovarian remnant syndrome in small animalsSíndrome do ovário remanescente em pequenos animais

    Directory of Open Access Journals (Sweden)

    Gilson Hélio Toniollo

    2012-04-01

    Full Text Available The ovarian remnant syndrome (ORS is an iatrogenic disorder in bitches and queens, which is characterized by recurrence of estrus following surgical spay, due to the presence of a piece of ovarian tissue within the abdominal cavity. In most cases, the remnant ovary is found in the right ovarian pedicle, due to its topographic position, deeper and more cranial than the left ovary. The main clinical signs of ORS in small animals are the heat behavior and the presence of vaginal swelling/secretion, especially in canines. The diagnosis should be performed by means of vaginal cytology when attraction of males is detected, serum estrogen and progesterone levels and/or by challenging test with GnRH or hCG administration. However, vaginal citology is the most suitable and less expensive diagnostic tool. Nowadays the treatment of choice is a new laparotomy or laparoscopy, followed by removal of the remnant ovarian tissue. The surgical treatment has more chances of success if it is performed in the diestrus (i.e., between 15 and 60 days after the detection of attraction of males. Furthermore, a careful and accurate surgical procedure aided by advanced visualization techniques during ovariohysterectomy or ovariectomy is the best way to prevent ORS in companion animals. A síndrome do ovário remanescente (SOR é um distúrbio iatrogênico em cadelas e gatas caracterizado pelo retorno do estro após contracepção cirúrgica devido à presença de fragmento de tecido ovariano na cavidade abdominal. Frequentemente, o ovário remanescente está situado no pedículo ovariano direito, sobretudo devido a sua posição topográfica mais profunda e cranial em comparação ao ovário esquerdo. Os principais sinais clínicos de SOR em pequenos animais são cio e presença de edemaciamento/secreção vulvar/vaginal, especialmente em caninos. O diagnóstico deve ser realizado por meio de citologia vaginal quando detecta-se o interesse dos machos pela cópula com a f

  7. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Directory of Open Access Journals (Sweden)

    J. Mejia

    2013-11-01

    Full Text Available The single photon emission microscope (SPEM is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD. Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  8. SU-E-T-575: Novel Quality Assurance Procedure for the Small Animal Radiation Research Platform Using Commercial OSLDs

    Energy Technology Data Exchange (ETDEWEB)

    Keller, J; Lockamy, V; Harrison, A [Thomas Jefferson University, Philadelphia, PA (United States); Glenn, S [Xstrahl Inc., Suwanee, GA (United States)

    2015-06-15

    Purpose: To support radiobiological research with the Xstrahl small animal radiation research platform (SARRP) by developing a simple and effective method using commercially available optically stimulated luminescent dosimeters (OSLDs) that ensures dose output consistency. Methods: The SARRP output is calibrated according to the vendor standards and TG-61 protocol utilizing an ADCL calibrated ion chamber and electrometer at 2 cm depth of solid water. A cross calibration is performed by replacing the ion chamber with five OSLDs at the 2 cm depth. The OSLDs are irradiated to 500 cGy with 220 keV at 13 mA (78s delivery time) with a copper filter for an uncollimated 17×17 cm{sup 2} aperture. Instead of the absolute dose, the total amount of raw counts are collected from the OSLD reader and used for analysis. This constancy procedure was performed two more times over the course of three weeks with two OLSDs for validity. Results: The average reading for all OSLDs is 494939 with a 1-sigma standard deviation of the 5.8%. With an acceptable dose output range of ±10%, the OSLD readings have a counts range of [445445, 544433]. Conclusion: This method of using nanoDot™ OSLDs to perform output constancy checks for the SARRP ensures the output of the device is within 10% from the time of calibration and is convenient as well as time efficient. Because this, the frequency of output checks can be increased, which can improve the output stability for research with this device. The output trend of the SARRP will continue to be monitored in the future to establish a timeline for constancy checks and recalibration.

  9. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    International Nuclear Information System (INIS)

    Mejia, J.; Reis, M.A.; Miranda, A.C.C.; Batista, I.R.; Barboza, M.R.F.; Shih, M.C.; Fu, G.; Chen, C.T.; Meng, L.J.; Bressan, R.A.; Amaro, E. Jr

    2013-01-01

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s -1 ·MBq -1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99m Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99m Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity

  10. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Reis, M.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Miranda, A.C.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Batista, I.R. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Barboza, M.R.F.; Shih, M.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Fu, G. [GE Global Research, Schenectady, NY (United States); Chen, C.T. [Department of Radiology, University of Chicago, Chicago, IL (United States); Meng, L.J. [Department of Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana-Champaign, IL (United States); Bressan, R.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Amaro, E. Jr [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil)

    2013-11-06

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s{sup -1}·MBq{sup -1} were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging {sup 99m}Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using {sup 99m}Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  11. Design and construction of a small animal PET/CT scanner combining scintillation Phoswich modules and hybrid pixels detectors

    International Nuclear Information System (INIS)

    Nicol, St.

    2010-07-01

    The pathway that has been followed by the imXgam team at CPPM was to combine on a single rotating device the detector modules of the small animal PET scanner ClearPET with a photon counting X-ray detector in order to perform simultaneous acquisition of images from the anatomy (X-ray CT) and from the metabolic function (PET) of the common field-of-view. A preliminary study of the hybrid imaging system ClearPET/XPAD3 carried out using Gate led us to form a new PET detection assembly based on 21 Phoswich modules, to fix the design of the PET/CT device, as well as to study and solve the difficulties arising from simultaneous hybrid imaging. Last but not least, the simulation tool also allowed us for thinking how well such a system could judiciously use the spatial and temporal correlations between anatomic and functional information. From an instrumentation point of view, we succeeded to set up the ClearPET/XPAD3 prototype. Once both imaging systems were operational individually, we demonstrated on one side that the ClearPET prototype was perfectly capable of performing correctly in simultaneous acquisition conditions, providing that the detector modules were appropriately shielded. On the other side, the new generation of the hybrid pixel camera using the XPAD3-S chip proved to be quite promising given the good quality of the first reconstructed images. Finally, the proof of concept of simultaneous PET/CT data acquisition was made using a sealed positron source and an X-ray tube. (author)

  12. Development of hypoparathyroidism animal model and the feasibility of small intestinal submucosa application on the parathyroid autotransplantation.

    Science.gov (United States)

    Park, Hae Sang; Jung, Soo Yeon; Kim, Ha Young; Kim, Da Yeon; Kim, Moon Suk; Chung, Sung Min; Rho, Young-Soo; Kim, Han Su

    2015-10-01

    The purpose of this study is to evaluate the feasibility of small intestinal submucosa (SIS) application on the parathyroid autotransplantation in a rat model of hypoparathyroidism. The rats were divided into four groups: NC (no procedure, n = 5), PTX (total parathyroidectomy, n = 6), PT (total parathyroidectomy and parathyroid autotransplantation, n = 10) and PT + SIS group (total parathyroidectomy and parathyroid autotransplantation with SIS, n = 10). The levels of parathyroid hormone (PTH), calcium, and phosphorous were measured on 0, 3, 7, 21, 56 and 84 days after surgery. PTH level was expressed as median (interquartile range) and histological and immunohistochemical examinations were performed. PTH levels were significantly decreased to "not detectable level" from day 3 in PTX group. PTH was not detected in both PT and PT + SIS groups on the 21st day. On the 56th day, PTH levels were increased in both groups: 3 out of 8 rats (37.5%) in the PT group, 6 out of 9 rats (66.7%) in the PT + SIS group. The PTH level was fully recovered to its preoperative range on the day 84 as 6 of 8 rats (75%) of the PT group and 7 of 9 rats (77.8%) of the PT + SIS group were recovered; the PTH levels were 117.84 and 178.36 pg/ml, respectively. The neo-vascularization was well observed around the parathyroid tissue, and the number of new vessels formed was higher in the PT + SIS group (15 vessels/high power field) as compared to the PT group (10 vessels/high power field). This study showed the feasibility and the treatment effect of SIS as the success rate of autotransplantation of parathyroid tissue was significantly increased without severe inflammatory response in hypothyroidism animal model.

  13. Radiography atlas of domestic animals. Small mammals, birds, reptilia, and amphibia. Atlas der Roentgendiagnostik bei Heimtieren. Kleinsaeuger, Voegel, Reptilien und Amphibien

    Energy Technology Data Exchange (ETDEWEB)

    Ruebel, G.A.; Isenbuegel, E.; Wolvekamp, P. (eds.); Gabrisch, K.; Grimm, F.; Koblik, P.; Paul-Murphy, J.; Oschwald, C.P.; Schildger, B.J.

    1991-01-01

    The 370 radiographs presented in the atlas together with notes and explanations give information on normal roentgenographic findings, physiological variations, and important pathological findings observed in small mammals, birds, reptilia and amphibia. Introductory notes to each chapter explain the principles of exposure techniques and the handling of the animals. (VHE).

  14. Effect of emaciation and obesity on small-animal internal radiation dosimetry for positron-emitting radionuclides

    NARCIS (Netherlands)

    Xie, Tianwu; Zaidi, Habib

    2013-01-01

    Purpose Rats are widely used in biomedical research involving molecular imaging and therefore the radiation dose to animals has become a concern. The weight of laboratory animals might change through emaciation or obesity as a result of their use in various research experiments including those

  15. Automated computer quantification of breast cancer in small-animal models using PET-guided MR image co-segmentation.

    Science.gov (United States)

    Bagci, Ulas; Kramer-Marek, Gabriela; Mollura, Daniel J

    2013-07-05

    Care providers use complementary information from multiple imaging modalities to identify and characterize metastatic tumors in early stages and perform surveillance for cancer recurrence. These tasks require volume quantification of tumor measurements using computed tomography (CT) or magnetic resonance imaging (MRI) and functional characterization through positron emission tomography (PET) imaging. In vivo volume quantification is conducted through image segmentation, which may require both anatomical and functional images available for precise tumor boundary delineation. Although integrating multiple image modalities into the segmentation process may improve the delineation accuracy and efficiency, due to variable visibility on image modalities, complex shape of metastatic lesions, and diverse visual features in functional and anatomical images, a precise and efficient segmentation of metastatic breast cancer remains a challenging goal even for advanced image segmentation methods. In response to these challenges, we present here a computer-assisted volume quantification method for PET/MRI dual modality images using PET-guided MRI co-segmentation. Our aims in this study were (1) to determine anatomical tumor volumes automatically from MRI accurately and efficiently, (2) to evaluate and compare the accuracy of the proposed method with different radiotracers (18F-Z HER2-Affibody and 18F-flourodeoxyglucose (18F-FDG)), and (3) to confirm the proposed method's determinations from PET/MRI scans in comparison with PET/CT scans. After the Institutional Administrative Panel on Laboratory Animal Care approval was obtained, 30 female nude mice were used to construct a small-animal breast cancer model. All mice were injected with human breast cancer cells and HER2-overexpressing MDA-MB-231HER2-Luc cells intravenously. Eight of them were selected for imaging studies, and selected mice were imaged with MRI, CT, and 18F-FDG-PET at weeks 9 and 10 and then imaged with 18F-Z HER2

  16. Development in Belgium of pinhole tomo-scintigraphy and of its applications to human and to small animals; Developpement en Belgique de la tomoscintigraphie stenopeique et de ses applications a l'homme et au petit animal

    Energy Technology Data Exchange (ETDEWEB)

    Seret, A. [Liege Univ., Institut de Physique, Imagerie Medicale Experimentale (Belgium)

    2006-06-15

    In Belgium, several researchers have been highly active in developing pinhole tomo-scintigraphy and have sometimes made a pioneer work. Their contributions concern as well the methodology of the technique as its applications to human and small animals. Reconstruction algorithms, of analytic and iterative type, have been developed and validated. They can reconstruct data obtained along circular, half-circular and non-circular acquisition orbits, the camera head being eventually tilted. A very performing method has been elaborated to determine the seven geometric parameters of the acquisition that are needed for an optimal reconstruction. The use of pinhole tomo-scintigraphy for thyroid exploration seems to be born in Belgium and a few validation studies were conducted in the country. Potentials of pinhole tomography application to parathyroid or bone scintigraphy have also been considered. Finally, some research groups are using pinhole tomo-scintigraphy for small animal studies. (author)

  17. MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP.

    Directory of Open Access Journals (Sweden)

    Shandra Gutierrez

    Full Text Available Computed tomography (CT is the standard imaging modality in radiation therapy treatment planning (RTP. However, magnetic resonance (MR imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE, and two ultra-short echo time sequences with 20 μs (UTE1 and 2 ms (UTE2 echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%. When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT's cumulative radiation dose might contribute

  18. I-124 labeled recombinant human annexin V produced by E. coli for apoptosis image using small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J. H.; Lee, I. S.; Woo, S. K.; Woo, G. S.; Chung, W. S.; Kang, J. H.; Cheon, G. J.; Choi, C. W.; Urn, S. M. [Korea Institute of Radiological and Medical Sciences, Daejeon (Korea, Republic of)

    2007-07-01

    Annexin V labeled with radioisotope and optical probe has been used to detect apoptosis. To evaluate annexin V as a multimodal apoptosis imaging agent, large-scale preparation of Annexin V (AV) is preliminary. The aim of this study is to produce and purify recombinant human Annexin V (rh-AV) in E. coli system and radiolabeled rh-AV evaluate in vitro and in vivo apoptosis model system. Annexin V cDNA was obtained from human placenta and rh-AV cloning vector used fusion E. coli vector. Expression vector was based on the E. coli pET system. Induction of rh-AV was used Isopropyl--D-thiogalactoside (IPTG) and purification was used TALON metal affinity resin and T7 - Taq. Purification yield confirmed through SDS-PAGE. In camptothecin (0, 50, 100 uM) induced Jurkat T cell apoptosis model, AV-PI flow cytometry analysis and in vitro binding assay of I-124 labeled rh - AV were performed and compared. Small animal PET images of I-124 labeled rh-AV were obtained in Fas-mediated hepatic apoptosis model. Optimum expression condition was at 37, 250 rpm, 8 hr in 2X YT media including 1mM IPTG, Through two step purification process, rh-AV confirmed about 35 Kd single band by SDS-PAGE. As camptothecin concentration increasing, annexin V-FITC positive % increased in flow cytometry analysis and uptake of I-124 labeled rh-AV also increased. Annexin V-FITC positive % was correlated with and uptake of I-124 labeled rh-AV (R{sup 2}=0.99). In Fas-mediated hepatic apoptosis model, I-124 labeled rh-AV was selectively localized in liver region in PET image. Recombinant Human annexin V was produced by E. coli system and purified using two step affinity chromatography. Radiolabeled rh-AV was useful for the evaluation of apoptosis in vitro and in vivo model. Recombinant human annexin V could be used as apoptosis imaging agent with various radiolabel and optical probe.

  19. Utility of a prototype liposomal contrast agent for x-ray imaging of breast cancer: a proof of concept using micro-CT in small animals

    Science.gov (United States)

    Badea, C. T.; Samei, E.; Ghaghada, K.; Saunders, R.; Yuan, H.; Qi, Y.; Hedlund, L. W.; Mukundan, S.

    2008-03-01

    Imaging tumor angiogenesis in small animals is extremely challenging due to the size of the tumor vessels. Consequently, both dedicated small animal imaging systems and specialized intravascular contrast agents are required. The goal of this study was to investigate the use of a liposomal contrast agent for high-resolution micro-CT imaging of breast tumors in small animals. A liposomal blood pool agent encapsulating iodine with a concentration of 65.5 mg/ml was used with a Duke Center for In Vivo Microscopy (CIVM) prototype micro-computed tomography (micro-CT) system to image the R3230AC mammary carcinoma implanted in rats. The animals were injected with equivalent volume doses (0.02 ml/kg) of contrast agent. Micro-CT with the liposomal blood pool contrast agent ensured a signal difference between the blood and the muscle higher than 450 HU allowing the visualization of the tumors 3D vascular architecture in exquisite detail at 100-micron resolution. The micro-CT data correlated well with the histological examination of tumor tissue. We also studied the ability to detect vascular enhancement with limited angle based reconstruction, i.e. tomosynthesis. Tumor volumes and their regional vascular percentage were estimated. This imaging approach could be used to better understand tumor angiogenesis and be the basis for evaluating anti-angiogenic therapies.

  20. Pre-clinical in vivo models for the screening of bone biomaterials for oral/craniofacial indications: focus on small-animal models.

    Science.gov (United States)

    Stavropoulos, Andreas; Sculean, Anton; Bosshardt, Dieter D; Buser, Daniel; Klinge, Björn

    2015-06-01

    Preclinical in vivo experimental studies are performed for evaluating proof-of-principle concepts, safety and possible unwanted reactions of candidate bone biomaterials before proceeding to clinical testing. Specifically, models involving small animals have been developed for screening bone biomaterials for their potential to enhance bone formation. No single model can completely recreate the anatomic, physiologic, biomechanic and functional environment of the human mouth and jaws. Relevant aspects regarding physiology, anatomy, dimensions and handling are discussed in this paper to elucidate the advantages and disadvantages of small-animal models. Model selection should be based not on the 'expertise' or capacities of the team, but rather on a scientifically solid rationale, and the animal model selected should reflect the question for which an answer is sought. The rationale for using heterotopic or orthotopic testing sites, and intraosseous, periosseous or extraskeletal defect models, is discussed. The paper also discusses the relevance of critical size defect modeling, with focus on calvarial defects in rodents. In addition, the rabbit sinus model and the capsule model in the rat mandible are presented and discussed in detail. All animal experiments should be designed with care and include sample-size and study-power calculations, thus allowing generation of meaningful data. Moreover, animal experiments are subject to ethical approval by the relevant authority. All procedures and the postoperative handling and care, including postoperative analgesics, should follow best practice. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Effect of emaciation and obesity on small-animal internal radiation dosimetry for positron-emitting radionuclides

    OpenAIRE

    Xie Tianwu; Zaidi Habib

    2013-01-01

    Purpose: Rats are widely used in biomedical research involving molecular imaging and therefore the radiation dose to animals has become a concern. The weight of laboratory animals might change through emaciation or obesity as a result of their use in various research experiments including those investigating different diet types. In this work we evaluated the effects of changes in body weight induced by emaciation and obesity on the internal radiation dose from common positron emitting radion...

  2. A conceptual framework for the economic analysis of factors influencing decision-making of small-scale farmers in animal health management.

    Science.gov (United States)

    Chilonda, P; Van Huylenbroeck, G

    2001-12-01

    The delivery of veterinary services in most of sub-Saharan Africa has undergone substantial changes, with the private sector gaining increasing recognition as an alternative to state provision. Given this policy shift, the authors argue that a better understanding of the behaviour and decision-making processes of small-scale farmers in animal health management is urgently required, to guide policy decisions regarding the delivery of animal health services. Whether the involvement of the private sector will improve overall efficiency in the delivery of veterinary services will depend greatly on the demand response of livestock producers who must make decisions about the health of livestock. The authors briefly review the decision-making process in small-scale farming systems, the economic nature of animal diseases and disease control and the models that have been used to guide resource allocation for disease control. To gain an improved understanding of the behaviour and decision-making processes of small-scale farmers, the authors propose a conceptual model including variables that relate to characteristics specific to small-scale farmers and farms, economic factors, institutional setting and biophysical factors. Two possible approaches are proposed for the economic analysis. Agricultural household modelling allows the derivation and testing of hypotheses regarding the demand elasticities for veterinary services, while qualitative choice models are better suited to the analysis of determinants behind the choices of farmers. The authors conclude that an urgent need exists for empirical research in this area.

  3. Kindergarten Animation

    Science.gov (United States)

    Hinshaw, Craig

    2012-01-01

    Animation is one of the last lessons that come to mind when thinking of kindergarten art. The necessary understanding of sequencing, attention to small, often detailed drawings, and the use of technology all seem more suitable to upper elementary. With today's emphasis on condensing and integrating curriculum, consider developing animation lessons…

  4. Comparison between sire-maternal grandsire and animal models for genetic evaluation of longevity in a dairy cattle population with small herds.

    Science.gov (United States)

    Jenko, J; Gorjanc, G; Kovač, M; Ducrocq, V

    2013-01-01

    Survival analysis techniques for sire-maternal grandsire (MGS) and animal models were used to test the genetic evaluation of longevity in a Slovenian Brown cattle population characterized by small herds. Three genetic models were compared: a sire-MGS model for bulls and an approximate animal model based on estimated breeding values (EBV) from the sire-MGS model for cows, an animal model, and an animal model based on the estimated variance components from the sire-MGS model. In addition, modeling the contemporary group effect was defined as either a herd or a herd-year (HY) effect. With various restrictions on the minimum HY group size (from 1 to 10 cows per HY), changes in estimates of variance components, and consequently also in EBV, were observed for the sire-MGS and animal models. Variance of contemporary group effects decreased when an HY effect was fitted instead of a herd effect. In the case of a sire-MGS model, estimates of additive genetic variance were mostly robust to changes in minimum HY group size or fitting herd or HY effect, whereas they increased in the animal model when HY instead of herd effects was fitted, possibly revealing some confounding between cow EBV and contemporary group effect. Estimated heritabilities from sire-MGS models were between 0.091 and 0.119 and were mainly influenced by the restriction on the HY group size. Estimated heritabilities from animal models were higher: between 0.125 and 0.160 when herd effect was fitted and between 0.171 and 0.210 when HY effect was fitted. Rank correlations between the animal model and the approximate animal model based on EBV from the sire-MGS model were high: 0.94 for cows and 0.93 for sires when a herd effect was fitted and 0.90 for cows and 0.93 for sires when an HY effect was fitted. Validation performed on the independent validation data set revealed that the correlation between sire EBV and daughter survival were slightly higher with the approximate animal model based on EBV from the sire

  5. Evaluation of spatial sensitivity of a prompt gamma neutron activation analysis facility for the in vivo determination of nitrogen in small animals

    International Nuclear Information System (INIS)

    Kasviki, K.; Ioannina University; Stamatelatos, I.E.; Kalef-Ezra, J.

    2007-01-01

    We investigated the spatial dependence of the sensitivity of nitrogen measurement with a prompt gamma neutron activation analysis (PGNAA) system for small animals and developed an analysis procedure that permits the reduction of systematic errors due to that dependence. The analysis procedure is based on neutron and photon transport calculations performed using the MCNP code in order to evaluate the sensitivity of the PGNAA facility. The system can be calibrated experimentally using a small number of phantoms of known size and composition. The calculation approach can then be used to predict responses for animal body sizes and shapes relatively to those experimentally determined and to include the effect of tissue inhomogeneities. Our calculations were verified by experimental measurements performed for a set of cylindrical inhomogeneous phantoms. The calculated to experimental ratios observed were within 6%. (author)

  6. Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

    Directory of Open Access Journals (Sweden)

    Deepu R Pillai

    Full Text Available BACKGROUND: Small animal models of human diseases are an indispensable aspect of pre-clinical research. Being dynamic, most pathologies demand extensive longitudinal monitoring to understand disease mechanisms, drug efficacy and side effects. These considerations often demand the concomitant development of monitoring systems with sufficient temporal and spatial resolution. METHODOLOGY AND RESULTS: This study attempts to configure and optimize a clinical 3 Tesla magnetic resonance scanner to facilitate imaging of small animal central nervous system pathologies. The hardware of the scanner was complemented by a custom-built, 4-channel phased array coil system. Extensive modification of standard sequence protocols was carried out based on tissue relaxometric calculations. Proton density differences between the gray and white matter of the rodent spinal cord along with transverse relaxation due to magnetic susceptibility differences at the cortex and striatum of both rats and mice demonstrated statistically significant differences. The employed parallel imaging reconstruction algorithms had distinct properties dependent on the sequence type and in the presence of the contrast agent. The attempt to morphologically phenotype a normal healthy rat brain in multiple planes delineated a number of anatomical regions, and all the clinically relevant sequels following acute cerebral ischemia could be adequately characterized. Changes in blood-brain-barrier permeability following ischemia-reperfusion were also apparent at a later time. Typical characteristics of intra-cerebral haemorrhage at acute and chronic stages were also visualized up to one month. Two models of rodent spinal cord injury were adequately characterized and closely mimicked the results of histological studies. In the employed rodent animal handling system a mouse model of glioblastoma was also studied with unequivocal results. CONCLUSIONS: The implemented customizations including extensive

  7. Induction and Characterization of Immune Responses in Small Animals Using a Venezuelan Equine Encephalitis Virus (VEE) Replicon System, Expressing Human Immunodeficiency Virus Type 1 (HIV-1) Envelope Genes

    Science.gov (United States)

    2003-01-01

    Montelaro, and C. J. Issel. 1995. Enhanced sensitivity to neutralizing antibodies in a variant of equine infectious anemia virus is linked to amino acid...371-8. 64 36. Davis, N. L., L. V. Willis, J. F. Smith, and R. E. Johnston. 1989. In vitro synthesis of infectious venezuelan equine encephalitis...Characterization of Immune Responses in small animals using a Venezuelan Equine Encephalitis Virus (VEE) Replicon System, Expressing Human

  8. The fracture toughness of small animal cortical bone measured using arc-shaped tension specimens: Effects of bisphosphonate and deproteinization treatments.

    Science.gov (United States)

    Hunckler, Michael D; Chu, Ethan D; Baumann, Andrew P; Curtis, Tyler E; Ravosa, Matthew J; Allen, Matthew R; Roeder, Ryan K

    2017-12-01

    Small animal models, and especially transgenic models, have become widespread in the study of bone mechanobiology and metabolic bone disease, but test methods for measuring fracture toughness on multiple replicates or at multiple locations within a single small animal bone are lacking. Therefore, the objective of this study was to develop a method to measure cortical bone fracture toughness in multiple specimens and locations along the diaphysis of small animal bones. Arc-shaped tension specimens were prepared from the mid-diaphysis of rabbit ulnae and loaded to failure to measure the radial fracture toughness in multiple replicates per bone. The test specimen dimensions, crack length, and maximum load met requirements for measuring the plane strain fracture toughness. Experimental groups included a control group, bisphosphonate treatment group, and an ex vivo deproteinization treatment following bisphosphonate treatment (5 rabbits/group and 15 specimens/group). The fracture toughness of ulnar cortical bone from rabbits treated with zoledronic acid for six months exhibited no difference compared with the control group. Partially deproteinized specimens exhibited significantly lower fracture toughness compared with both the control and bisphosphonate treatment groups. The deproteinization treatment increased tissue mineral density (TMD) and resulted in a negative linear correlation between the measured fracture toughness and TMD. Fracture toughness measurements were repeatable with a coefficient of variation of 12-16% within experimental groups. Retrospective power analysis of the control and deproteinization treatment groups indicated a minimum detectable difference of 0.1MPa·m 1/2 . Therefore, the overall results of this study suggest that arc-shaped tension specimens offer an advantageous new method for measuring the fracture toughness in small animal bones. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Measuring of main parameters of blood circulation at small laboratory animals in chronic experiment by means of computerized gamma-camera

    International Nuclear Information System (INIS)

    Rutskij, A.V.; Kovalenko, Yu.D.; Rudenko, F.V.; Ioda, G.I.; Kaminskij, M.P.

    1996-01-01

    Technique for studding of a state systemic and regional hemodynamics at small laboratory animals (rats) by using short-lived isotopes (technetium 99 m) and computerized gamma-camera are described. One gives possibility to make the repeated measuring in condition long-tome experiment. The proposed technique of radiocardiocirculography gives possibility simultaneously to measure linear parameters of both arterial and vein blood circulation too. 3 refs., 1 tab., 2 figs

  10. Coil concepts for rapid and motion-compensated MR-Imaging of small animals; Spulenkonzepte zur schnellen und bewegungskompensierten MR-Bildgebung von Kleintieren

    Energy Technology Data Exchange (ETDEWEB)

    Korn, Matthias

    2009-05-06

    In this work radiofrequency-coils for the imaging of small animals in clinical whole-body MRI-systems were developed. Therefore in a first step single-channel solenoids were designed and characterized. The solenoids had two and three windings respectively, which were implemented as double wires to increase the homogeneity of the receive profile. These coils allow the acquisition of whole-body images of mice with high signal-to-noise ratio and homogeneity over a distance of at least 6.3 cm. Since many imaging experiments require rapid image acquisition, in the next step a novel coil concept was developed, which, due to its geometry, enables parallel imaging in arbitrary directions. A prototype was assembled and tested on phantom and small-animal experiments. With an accelerating factor of R=2, the difference of the SNR in all directions from the theoretical maximum, was less than 1%. In order to compensate physiological motion by the self-gating technique, in this work a coil is presented for the first time, which selectively amplifies the self-gating signal, while - due to a optical detuning technique - preserving the homogeneous illumination of the image. In vivo experiments on a small animal show an amplification of the self-gating signal by at least 40%. (orig.)

  11. Interdisciplinary Interactions within a Small-Scale Research Initiative Investigating Animation Creation as a Means of Teaching and Learning

    Science.gov (United States)

    Wishart, J. M.; Wakley, G.

    2017-01-01

    This paper reports an interdisciplinary research (IDR) initiative conducted by two lecturers from different university faculties who found they shared an interest in using animations to support teaching and learning. The research comprised an exploratory pilot to test the feasibility, and to explore the impact on learning, of having undergraduates…

  12. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    Energy Technology Data Exchange (ETDEWEB)

    Hrycushko, B; Medin, P [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  13. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    International Nuclear Information System (INIS)

    Hrycushko, B; Medin, P

    2016-01-01

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  14. Choline molecular imaging with small-animal PET for monitoring tumor cellular response to photodynamic therapy of cancer

    Science.gov (United States)

    Fei, Baowei; Wang, Hesheng; Wu, Chunying; Meyers, Joseph; Xue, Liang-Yan; MacLennan, Gregory; Schluchter, Mark

    2009-02-01

    We are developing and evaluating choline molecular imaging with positron emission tomography (PET) for monitoring tumor response to photodynamic therapy (PDT) in animal models. Human prostate cancer (PC-3) was studied in athymic nude mice. A second-generation photosensitizer Pc 4 was used for PDT in tumor-bearing mice. MicroPET images with 11C-choline were acquired before PDT and 48 h after PDT. Time-activity curves of 11C-choline uptake were analyzed before and after PDT. For treated tumors, normalized choline uptake decreased significantly 48 h after PDT, compared to the same tumors pre-PDT (p PET imaging with 11C-choline is sensitive to detect early tumor response to PDT in the animal model of human prostate cancer.

  15. Wavelet-based regularization and edge preservation for submillimetre 3D list-mode reconstruction data from a high resolution small animal PET system

    Energy Technology Data Exchange (ETDEWEB)

    Jesus Ochoa Dominguez, Humberto de, E-mail: hochoa@uacj.mx [Departamento de Ingenieria Eectrica y Computacion, Universidad Autonoma de Ciudad Juarez, Avenida del Charro 450 Norte, C.P. 32310 Ciudad Juarez, Chihuahua (Mexico); Ortega Maynez, Leticia; Osiris Vergara Villegas, Osslan; Gordillo Castillo, Nelly; Guadalupe Cruz Sanchez, Vianey; Gutierrez Casas, Efren David [Departamento de Ingenieria Eectrica y Computacion, Universidad Autonoma de Ciudad Juarez, Avenida del Charro 450 Norte, C.P. 32310 Ciudad Juarez, Chihuahua (Mexico)

    2011-10-01

    The data obtained from a PET system tend to be noisy because of the limitations of the current instrumentation and the detector efficiency. This problem is particularly severe in images of small animals as the noise contaminates areas of interest within small organs. Therefore, denoising becomes a challenging task. In this paper, a novel wavelet-based regularization and edge preservation method is proposed to reduce such noise. To demonstrate this method, image reconstruction using a small mouse {sup 18}F NEMA phantom and a {sup 18}F mouse was performed. Investigation on the effects of the image quality was addressed for each reconstruction case. Results show that the proposed method drastically reduces the noise and preserves the image details.

  16. Computerized detection and analysis of cancer chemotherapy-induced emesis in a small animal model, musk shrew

    OpenAIRE

    Huang, Dong; Meyers, Kelly; Henry, Séverine; De la Torre, Fernando; Horn, Charles C.

    2011-01-01

    Vomiting is a common side effect of cancer chemotherapy and many drug treatments and diseases. In animal studies, the measurement of vomiting usually requires direct observation, which is time consuming and often lacks temporal precision. Musk shrews have been used to study the neurobiology of emesis and have a rapid emetic episode (~1 s for a sequence of retching and expulsion). The aims of the current study were to develop a method to automatically detect and characterize emetic episodes in...

  17. A framework for inverse planning of beam-on times for 3D small animal radiotherapy using interactive multi-objective optimisation

    International Nuclear Information System (INIS)

    Balvert, Marleen; Den Hertog, Dick; Van Hoof, Stefan J; Granton, Patrick V; Trani, Daniela; Hoffmann, Aswin L; Verhaegen, Frank

    2015-01-01

    Advances in precision small animal radiotherapy hardware enable the delivery of increasingly complicated dose distributions on the millimeter scale. Manual creation and evaluation of treatment plans becomes difficult or even infeasible with an increasing number of degrees of freedom for dose delivery and available image data. The goal of this work is to develop an optimisation model that determines beam-on times for a given beam configuration, and to assess the feasibility and benefits of an automated treatment planning system for small animal radiotherapy.The developed model determines a Pareto optimal solution using operator-defined weights for a multiple-objective treatment planning problem. An interactive approach allows the planner to navigate towards, and to select the Pareto optimal treatment plan that yields the most preferred trade-off of the conflicting objectives. This model was evaluated using four small animal cases based on cone-beam computed tomography images. Resulting treatment plan quality was compared to the quality of manually optimised treatment plans using dose-volume histograms and metrics.Results show that the developed framework is well capable of optimising beam-on times for 3D dose distributions and offers several advantages over manual treatment plan optimisation. For all cases but the simple flank tumour case, a similar amount of time was needed for manual and automated beam-on time optimisation. In this time frame, manual optimisation generates a single treatment plan, while the inverse planning system yields a set of Pareto optimal solutions which provides quantitative insight on the sensitivity of conflicting objectives. Treatment planning automation decreases the dependence on operator experience and allows for the use of class solutions for similar treatment scenarios. This can shorten the time required for treatment planning and therefore increase animal throughput. In addition, this can improve treatment standardisation and

  18. Physical and biological dosimetry at the RA-3 facility for small animal irradiation: preliminary BNCT studies in an experimental model of oral cancer

    International Nuclear Information System (INIS)

    Pozzi, Emiliano; Miller, Marcelo; Thorp, Silvia I.; Heber, Elisa M.; Trivillin, Veronica A.; Zarza, Leandro; Estryk, Guillermo; Schwint, Amanda E.; Nigg, David W.

    2007-01-01

    Boron Neutron Capture Therapy (BNCT) is a binary treatment modality based on the capture reaction that occurs between thermal neutrons and boron-10 atoms that accumulate selectively in tumor tissue, emitting high linear energy transfer (LET), short range (5-9 microns) particles (alpha y 7 Li). Thus, BNCT would potentially target tumor tissue selectively, sparing normal tissue. Herein we evaluated the feasibility of treating experimental oral mucosa tumors with BNCT at RA-3 (CAE) employing the hamster cheek pouch oral cancer model and characterized the irradiation field at the RA-3 facility. We evaluated the therapeutic effect on tumor of BNCT mediated by BPA in the hamster cheek pouch oral cancer model and the potential radio toxic effects in normal tissue. We evidenced a moderate biological response in tumor, with no radio toxic effects in normal tissue following irradiations with no shielding for the animal body. Given the sub-optimal therapeutic response, we designed and built a 6 Li 2 CO 3 shielding for the body of the animal to increase the irradiation dose to tumor, without exceeding normal tissue radio tolerance. The measured absolute magnitude of thermal neutron flux and the characterization of the beam with and without the shielding in place, suggest that the irradiation facility in the thermal column of RA-3 would afford an excellent platform to perform BNCT studies in vitro and in vivo in small experimental animals. The present findings must be confirmed and extended by performing in vivo BNCT radiobiological studies in small experimental animals, employing the shielding device for the animal body. (author) [es

  19. Assessment of a chemically induced model of lung squamous cell carcinoma in mice by 18F-FDG small-animal PET.

    Science.gov (United States)

    Ambrosini, Valentina; Nanni, Cristina; Pettinato, Cinzia; Fini, Milena; D'Errico, Antonia; Trepidi, Silvia; Spinelli, Antonello; Al-Nahhas, Adil; Rubello, Domenico; Zompatori, Maurizio; Fabbri, Mario; Franchi, Roberto; Fanti, Stefano

    2007-08-01

    Small-animal imaging has become a relevant research field in pre-clinical oncology. In particular, metabolic information provided by small-animal positron emission tomography (PET) is very useful to closely monitor tumour growth and assess therapy response in murine models of human disease. There are various murine models for human lung adenocarcinoma, but those for squamous cell lung carcinoma, the most common form of human cancer, are lacking. To assess the feasibility of 18F-FDG small-animal PET to monitor tumour growth in a chemically induced model of squamous cell carcinoma of the lung. Nineteen NIH Swiss mice were skin painted by N-nitroso-tris-chloroethylurea (NTCU) twice a week, with a 3 day interval, for 8 months and 10 NIH Swiss mice skin painted with NTCU solvent (acetone) were used as controls. 18F-FDG PET was performed under sevofluorane anaesthesia and oxygen supplementation at 2, 4, 6 and 8 months from initial treatment. Images were assessed by visual analysis and semi-quantitatively. When a diffuse distribution of tumour was noted, the mean of the counts/pixel measured at three lung levels, corrected for the effective dose injected and for decay, was used for comparison between mutagen-painted and control mice. Pathological evaluation was carried out from the time of the first positive PET results in a subgroup of the whole population to assess correlation with PET findings. Small animal CT was performed at 8 months in another subgroup. In both terms of visual analysis and measurement of total lung activity, 18F-FDG PET at 2 and 4 months from initial treatment were comparable in mutagen-painted and controls. At 6 months, PET images showed a faint and diffuse uptake over both lung fields in mutagen-painted mice with multiple focal areas of increased tracer uptake that merged into confluent masses at 8 months and seriously subverting lung architecture on computed tomography. Total lung activity was significantly higher in mutagen-painted versus

  20. Real-time bladder volume monitoring by the application of a new implantable bladder volume sensor for a small animal model

    Directory of Open Access Journals (Sweden)

    Dong Sup Lee

    2011-04-01

    Full Text Available Although real-time monitoring of bladder volume together with intravesical pressure can provide more information for understanding the functional changes of the urinary bladder, it still entails difficulties in the accurate prediction of real-time bladder volume in urodynamic studies with small animal models. We studied a new implantable bladder volume monitoring device with eight rats. During cystometry, microelectrodes prepared by the microelectromechanical systems process were placed symmetrically on both lateral walls of the bladder, and the expanded bladder volume was calculated. Immunohistological study was done after 1 week and after 4 weeks to evaluate the biocompatibility of the microelectrode. From the point that infused saline volume into the bladder was higher than 0.6 mL, estimated bladder volume was statistically correlated with the volume of saline injected (p<0.01. Additionally, the microelectromechanical system microelectrodes used in this study showed reliable biocompatibility. Therefore, the device can be used to evaluate changes in bladder volume in studies with small animals, and it may help to provide more information about functional changes in the bladder in laboratory studies. Furthermore, owing to its biocompatibility, the device could be chronically implanted in conscious ambulating animals, thus allowing a novel longitudinal study to be performed for a specific purpose.

  1. Instruments for radiation measurement in life sciences (5), ''Development of imaging technology in life sciences'' III. Development of small animal PET scanners

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Murayama, Hideo

    2006-01-01

    This paper summarizes the requisites for small animal PET scanners, present state of their market and of their development in National Institute of Radiological Sciences (NIRS). Relative to the apparatus clinically used, the requisites involve the high spatial resolution of 0.8-1.5 mm and high sensitivity of the equipment itself due to low dose of the tracer to be given to animals. At present, more than 20 institutions like universities, research facilities and companies are developing the PET equipment for small animals and about 10 machines are in the market. However, their resolution and sensitivity are not fully satisfactory and for their improvement, investigators are paying attention to the gamma ray measurement by depth-of-interaction (DOI) method. NIRS has been also developing the machine jPET-D4 and has proposed to manufacture jPET-RD having 4-layer DOI detectors with the absolute central sensitivity as high as 14.7%. jPET-RD is to have the spatial resolution as high as <1mm (central view) and -1.4 mm (periphery). (T.I.)

  2. Anatomical features for an adequate choice of experimental animal model in biomedicine: II. Small laboratory rodents, rabbit, and pig.

    Science.gov (United States)

    Lossi, Laura; D'Angelo, Livia; De Girolamo, Paolo; Merighi, Adalberto

    2016-03-01

    The anatomical features distinctive to each of the very large array of species used in today's biomedical research must be born in mind when considering the correct choice of animal model(s), particularly when translational research is concerned. In this paper we take into consideration and discuss the most important anatomical and histological features of the commonest species of laboratory rodents (rat, mouse, guinea pig, hamster, and gerbil), rabbit, and pig related to their importance for applied research. Copyright © 2015 Elsevier GmbH. All rights reserved.

  3. METHOD FOR SIMULTANEOUS 90SR AND 137CS IN-VIVO MEASUREMENTS OF SMALL ANIMALS AND OTHER ENVIRONMENTAL MEDIA DEVELOPED FOR THE CONDITIONS OF THE CHERNOBYL EXCLUSION ZONE

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.; Jannik, T.

    2011-10-01

    To perform in vivo simultaneous measurements of the {sup 90}Sr and {sup 137}Cs content in the bodies of animals living in the Chernobyl Exclusion Zone (ChEZ), an appropriate method and equipment were developed and installed in a mobile gamma beta spectrometry laboratory. This technique was designed for animals of relatively small sizes (up to 50 g). The {sup 90}Sr content is measured by a beta spectrometer with a 0.1 mm thick scintillation plastic detector. The spectrum processing takes into account the fact that the measured object is 'thick-layered' and contains a comparable quantity of {sup 137}Cs, which is a characteristic condition of the ChEZ. The {sup 137}Cs content is measured by a NaI scintillation detector that is part of the combined gamma beta spectrometry system. For environmental research performed in the ChEZ, the advantages of this method and equipment (rapid measurements, capability to measure live animals directly in their habitat, and the capability of simultaneous {sup 90}Sr and {sup 137}Cs measurements) far outweigh the existing limitations (considerations must be made for background radiation and the animal size, skeletal shape and body mass). The accuracy of these in vivo measurements is shown to be consistent with standard spectrometric and radiochemical methods. Apart from the in vivo measurements, the proposed methodology, after a very simple upgrade that is also described in the article, works even more accurately with samples of other media, such as soil and plants.

  4. P.I.X.S.C.A.N.: a micro-CT scanner for small animal based on hybrid pixel detectors; PIXSCAN: micro-tomodensitrometre a pixels hybrides pour le petit animal

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, R

    2008-03-15

    Since more than a dozen years, efforts were led in the field of X-ray tomography for small animals, principally for the improvement of spatial resolution and the diminution of the absorbed dose. The C.P.P.M. developed the micro-CT P.I.X.S.C.A.N. based on the hybrid pixel detector X.P.A.D.2. In this context, my thesis work consists in studying the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 and the contribution of the hybrid pixels in the imaging of small animals. A fast analytical simulation, FastSimu, was developed. An extrapolation of the performance of the demonstrator P.I.X.S.C.A.N, as well as the validation of the results obtained with the measured data, were led by means of the analytical simulator FastSimu. The demonstrator P.I.X.S.C.A.N./X.P.A.D.2 allowed to obtain reconstructed images with a rather good quality for a relatively weak absorbed dose. Its spatial resolution is degraded by the high number of defective pixels of the detector X.P.A.D.2. Beyond this study, a new version of the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 is under construction. This latter, characterized by two and a half times smaller pixels and about no defective pixels will bring a considerable improvement on spatial resolution. (author)

  5. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    OpenAIRE

    Mejia, J.; Reis, M.A.; Miranda, A.C.C.; Batista, I.R.; Barboza, M.R.F.; Shih, M.C.; Fu, G.; Chen, C.T.; Meng, L.J.; Bressan, R.A.; Amaro Jr, E.

    2013-01-01

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and ...

  6. Tapping the Vast Potential of the Data Deluge in Small-scale Food-Animal Production Businesses: Challenges to Near Real-time Data Analysis and Interpretation

    Directory of Open Access Journals (Sweden)

    Flavie Vial

    2017-09-01

    Full Text Available Food-animal production businesses are part of a data-driven ecosystem shaped by stringent requirements for traceability along the value chain and the expanding capabilities of connected products. Within this sector, the generation of animal health intelligence, in particular, in terms of antimicrobial usage, is hindered by the lack of a centralized framework for data storage and usage. In this Perspective, we delimit the 11 processes required for evidence-based decisions and explore processes 3 (digital data acquisition to 10 (communication to decision-makers in more depth. We argue that small agribusinesses disproportionally face challenges related to economies of scale given the high price of equipment and services. There are two main areas of concern regarding the collection and usage of digital farm data. First, recording platforms must be developed with the needs and constraints of small businesses in mind and move away from local data storage, which hinders data accessibility and interoperability. Second, such data are unstructured and exhibit properties that can prove challenging to its near real-time preprocessing and analysis in a sector that is largely lagging behind others in terms of computing infrastructure and buying into digital technologies. To complete the digital transformation of this sector, investment in rural digital infrastructure is required alongside the development of new business models to empower small businesses to commit to near real-time data capture. This approach will deliver critical information to fill gaps in our understanding of emerging diseases and antimicrobial resistance in production animals, eventually leading to effective evidence-based policies.

  7. [Mechanism of Chlorogenic Acid in Apoptotic Regulation through Notch1 
Pathway in Non-small Cell Lung Carcinoma in Animal Level].

    Science.gov (United States)

    Li, Wei; Liu, Xu; Zhang, Guoqian; Zhang, Linlin

    2017-08-20

    It has been proven that chlorogenic acids can produce anticancer effects by regulating cell cycle, inducing apoptosis, inhibiting cell growth, Notch signaling pathways are closely related to many human tumors. The aim of this study is to study the mechanism of chlorogenic acid on apoptosis of non-small lung cancer through Notch1 pathway in animal level, and hope to provide theory basis on clinical treatment and research aimed at targeting Notch1 signaling in non-small cell carcinoma (NSCLC). MTT assay was used to evaluate the A549 cell proliferation under the treatment of chlorogenic acid. The effect of chlorogenic acid on apoptotic and cell cycle were detected by flow cytometry. The animal model of A549 cell transplanted in nude was established, tumer size and weight were detected. The mRNA level of Notch1 signal pathway related facter were detected by RT-PCR; the expression of Notch1 signal pathway related facter in tumor tissue was detected by western blot. Chlorogenic acid inhibited the A549 cell proliferation. incresed cell apoptotic and cell percentagein G2/M (Pchlorogenic. The expression of Notch1 were decreaced, PTEN, p-PTEN, p-AKT were increced significantly in tumor tissue which treated with chlorogenic (PChlorogenic acid can regulate theapoptosis of non-small lung cancer through Notch pathway in animal level, which may be associated with the down-regulating the expression of VEGF and Delta4. Notch pathway may cross talk with PI3K/AKT pathway through PTEN in NSCLC.

  8. Human Placenta-Derived Multipotent Cells (hPDMCs) Modulate Cardiac Injury: From Bench to Small and Large Animal Myocardial Ischemia Studies.

    Science.gov (United States)

    Liu, Yuan-Hung; Peng, Kai-Yen; Chiu, Yu-Wei; Ho, Yi-Lwun; Wang, Yao-Horng; Shun, Chia-Tung; Huang, Shih-Yun; Lin, Yi-Shuan; de Vries, Antoine A F; Pijnappels, Daniël A; Lee, Nan-Ting; Yen, B Linju; Yen, Men-Luh

    2015-01-01

    Cardiovascular disease is the leading cause of death globally, and stem cell therapy remains one of the most promising strategies for regeneration or repair of the damaged heart. We report that human placenta-derived multipotent cells (hPDMCs) can modulate cardiac injury in small and large animal models of myocardial ischemia (MI) and elucidate the mechanisms involved. We found that hPDMCs can undergo in vitro cardiomyogenic differentiation when cocultured with mouse neonatal cardiomyocytes. Moreover, hPDMCs exert strong proangiogenic responses in vitro toward human endothelial cells mediated by secretion of hepatocyte growth factor, growth-regulated oncogene-α, and interleukin-8. To test the in vivo relevance of these results, small and large animal models of acute MI were induced in mice and minipigs, respectively, by permanent left anterior descending (LAD) artery ligation, followed by hPDMC or culture medium-only implantation with follow-up for up to 8 weeks. Transplantation of hPDMCs into mouse heart post-acute MI induction improved left ventricular function, with significantly enhanced vascularity in the cell-treated group. Furthermore, in minipigs post-acute MI induction, hPDMC transplantation significantly improved myocardial contractility compared to the control group (p = 0.016) at 8 weeks postinjury. In addition, tissue analysis confirmed that hPDMC transplantation induced increased vascularity, cardiomyogenic differentiation, and antiapoptotic effects. Our findings offer evidence that hPDMCs can modulate cardiac injury in both small and large animal models, possibly through proangiogenesis, cardiomyogenesis, and suppression of cardiomyocyte apoptosis. Our study offers mechanistic insights and preclinical evidence on using hPDMCs as a therapeutic strategy to treat severe cardiovascular diseases.

  9. Tapping the Vast Potential of the Data Deluge in Small-scale Food-Animal Production Businesses: Challenges to Near Real-time Data Analysis and Interpretation.

    Science.gov (United States)

    Vial, Flavie; Tedder, Andrew

    2017-01-01

    Food-animal production businesses are part of a data-driven ecosystem shaped by stringent requirements for traceability along the value chain and the expanding capabilities of connected products. Within this sector, the generation of animal health intelligence, in particular, in terms of antimicrobial usage, is hindered by the lack of a centralized framework for data storage and usage. In this Perspective, we delimit the 11 processes required for evidence-based decisions and explore processes 3 (digital data acquisition) to 10 (communication to decision-makers) in more depth. We argue that small agribusinesses disproportionally face challenges related to economies of scale given the high price of equipment and services. There are two main areas of concern regarding the collection and usage of digital farm data. First, recording platforms must be developed with the needs and constraints of small businesses in mind and move away from local data storage, which hinders data accessibility and interoperability. Second, such data are unstructured and exhibit properties that can prove challenging to its near real-time preprocessing and analysis in a sector that is largely lagging behind others in terms of computing infrastructure and buying into digital technologies. To complete the digital transformation of this sector, investment in rural digital infrastructure is required alongside the development of new business models to empower small businesses to commit to near real-time data capture. This approach will deliver critical information to fill gaps in our understanding of emerging diseases and antimicrobial resistance in production animals, eventually leading to effective evidence-based policies.

  10. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B; He, W; Cvetkovic, D; Chen, L; Fan, J; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

  11. Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Park, S-J; Yu, A R; Lee, Y-J; Kim, Y-S; Kim, H-J

    2014-01-01

    Dedicated single-photon-emission computed tomography (SPECT) systems based on pixelated semiconductors such as cadmium telluride (CdTe) are in development to study small animal models of human disease. In an effort to develop a high-resolution, low-dose system for small animal imaging, we compared a CdTe-based SPECT system and a conventional NaI(Tl)-based SPECT system in terms of spatial resolution, sensitivity, contrast, and contrast-to-noise ratio (CNR). In addition, we investigated the radiation absorbed dose and calculated a figure of merit (FOM) for both SPECT systems. Using the conventional NaI(Tl)-based SPECT system, we achieved a spatial resolution of 1.66 mm at a 30 mm source-to-collimator distance, and a resolution of 2.4-mm hot-rods. Using the newly-developed CdTe-based SPECT system, we achieved a spatial resolution of 1.32 mm FWHM at a 30 mm source-to-collimator distance, and a resolution of 1.7-mm hot-rods. The sensitivities at a 30 mm source-to-collimator distance were 115.73 counts/sec/MBq and 83.38 counts/sec/MBq for the CdTe-based SPECT and conventional NaI(Tl)-based SPECT systems, respectively. To compare quantitative measurements in the mouse brain, we calculated the CNR for images from both systems. The CNR from the CdTe-based SPECT system was 4.41, while that from the conventional NaI(Tl)-based SPECT system was 3.11 when the injected striatal dose was 160 Bq/voxel. The CNR increased as a function of injected dose in both systems. The FOM of the CdTe-based SPECT system was superior to that of the conventional NaI(Tl)-based SPECT system, and the highest FOM was achieved with the CdTe-based SPECT at a dose of 40 Bq/voxel injected into the striatum. Thus, a CdTe-based SPECT system showed significant improvement in performance compared with a conventional system in terms of spatial resolution, sensitivity, and CNR, while reducing the radiation dose to the small animal subject. Herein, we discuss the feasibility of a CdTe-based SPECT system for high

  12. Methods for study of cardiovascular adaptation of small laboratory animals during exposure to altered gravity. [hypothermia for cardiovascular control and cancer therapy

    Science.gov (United States)

    Popovic, V.

    1973-01-01

    Several new techniques are reported for studying cardiovascular circulation in small laboratory animals kept in metabolic chambers. Chronical cannulation, miniaturized membrane type heart-lung machines, a prototype walking chamber, and a fluorocarbon immersion method to simulate weightlessness are outlined. Differential hypothermia work on rat cancers provides localized embedding of radionuclides and other chemotherapeutical agents in tumors and increases at the same time blood circulation through the warmed tumor as compared to the rest of the cold body. Some successful clinical applications of combined chemotherapy and differential hypothermia in skin cancer, mammary tumors, and brain gliomas are described.

  13. Quantitation of dopamine transporter blockade by methylphenidate: first in vivo investigation using [{sup 123}I]FP-CIT and a dedicated small animal SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaus, Susanne; Wirrwar, Andreas; Antke, Christina; Arkian, Shahram; Mueller, Hans-Wilhelm; Larisch, Rolf [Heinrich-Heine University, Clinic of Nuclear Medicine, Duesseldorf (Germany); Schramm, Nils [Research Center Juelich, Central Laboratory for Electronics, Juelich (Germany)

    2005-03-01

    The aim of this study was to investigate the feasibility of assessing dopamine transporter binding after treatment with methylphenidate in the rat using a recently developed high-resolution small animal single-photon emission computed tomograph (TierSPECT) and [{sup 123}I]FP-CIT. [{sup 123}I]FP-CIT was administered intravenously 1 h after intraperitoneal injection of methylphenidate (10 mg/kg) or vehicle. Animals underwent scanning 2 h after radioligand administration. The striatum was identified by superimposition of [{sup 123}I]FP-CIT scans with bone metabolism and perfusion scans obtained with {sup 99m}Tc-DPD and {sup 99m}Tc-tetrofosmin, respectively. As these tracers do not pass the blood-brain barrier, their distribution permits the identification of extracerebral anatomical landmarks such as the orbitae and the harderian glands. The cerebellum was identified by superimposing [{sup 123}I]FP-CIT scans with images of brain perfusion obtained with {sup 99m}Tc-HMPAO. Methylphenidate-treated animals and vehicle-treated animals yielded striatal equilibrium ratios (V''{sub 3}) of 0.24{+-}0.26 (mean {+-} SD) and 1.09{+-}0.42, respectively (ttest, two-tailed, p<0.0001). Cortical V''{sub 3} values amounted to 0.05{+-}0.28 (methylphenidate) and 0.3{+-}0.39 (saline, p=0.176). This first in vivo study of rat dopamine transporter binding after pre-treatment with methylphenidate showed a mean reduction of 78% in striatal [{sup 123}I]FP-CIT accumulation. The results can be interpreted in terms of a pharmacological blockade in the rat striatum and show that in vivo quantitation of dopamine transporter binding is feasible with [{sup 123}I]FP-CIT and the TierSPECT. This may be of future relevance for in vivo investigations on rat models of attention deficit/hyperactivity disorder. Furthermore, our findings suggest that investigations in other animal models, e.g. of Parkinson's and Huntington's disease, may be feasible using SPECT radioligands and

  14. Quantitation of dopamine transporter blockade by methylphenidate: first in vivo investigation using [123I]FP-CIT and a dedicated small animal SPECT

    International Nuclear Information System (INIS)

    Nikolaus, Susanne; Wirrwar, Andreas; Antke, Christina; Arkian, Shahram; Mueller, Hans-Wilhelm; Larisch, Rolf; Schramm, Nils

    2005-01-01

    The aim of this study was to investigate the feasibility of assessing dopamine transporter binding after treatment with methylphenidate in the rat using a recently developed high-resolution small animal single-photon emission computed tomograph (TierSPECT) and [ 123 I]FP-CIT. [ 123 I]FP-CIT was administered intravenously 1 h after intraperitoneal injection of methylphenidate (10 mg/kg) or vehicle. Animals underwent scanning 2 h after radioligand administration. The striatum was identified by superimposition of [ 123 I]FP-CIT scans with bone metabolism and perfusion scans obtained with 99m Tc-DPD and 99m Tc-tetrofosmin, respectively. As these tracers do not pass the blood-brain barrier, their distribution permits the identification of extracerebral anatomical landmarks such as the orbitae and the harderian glands. The cerebellum was identified by superimposing [ 123 I]FP-CIT scans with images of brain perfusion obtained with 99m Tc-HMPAO. Methylphenidate-treated animals and vehicle-treated animals yielded striatal equilibrium ratios (V '' 3 ) of 0.24±0.26 (mean ± SD) and 1.09±0.42, respectively (ttest, two-tailed, p '' 3 values amounted to 0.05±0.28 (methylphenidate) and 0.3±0.39 (saline, p=0.176). This first in vivo study of rat dopamine transporter binding after pre-treatment with methylphenidate showed a mean reduction of 78% in striatal [ 123 I]FP-CIT accumulation. The results can be interpreted in terms of a pharmacological blockade in the rat striatum and show that in vivo quantitation of dopamine transporter binding is feasible with [ 123 I]FP-CIT and the TierSPECT. This may be of future relevance for in vivo investigations on rat models of attention deficit/hyperactivity disorder. Furthermore, our findings suggest that investigations in other animal models, e.g. of Parkinson's and Huntington's disease, may be feasible using SPECT radioligands and small animal imaging systems. (orig.)

  15. Investigation of the imaging characteristics of the ALBIRA II small animal PET system for {sup 18}F, {sup 68}Ga and {sup 64}Cu

    Energy Technology Data Exchange (ETDEWEB)

    Attarwala, Ali Asgar; Hardiansyah, Deni [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Karanja, Yvonne Wanjiku; Romano, Chiara [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Roscher, Mareike; Waengler, Bjoern [Heidelberg Univ., Mannheim (Germany). Molecular Imaging and Radiochemistry; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Ulm Univ. (Germany). Dept. of Nuclear Medicine

    2017-08-01

    In this study the performance characteristics of the Albira II PET sub-system and the response of the system for the following radionuclides {sup 18}F, {sup 68}Ga and {sup 64}Cu was analyzed. The Albira II tri-modal system (Bruker BioSpin MRI GmbH, Ettlingen, Germany) is a pre-clinical device for PET, SPECT and CT. The PET sub-system uses single continuous crystal detectors of lutetium yttrium orthosilicate (LYSO). The detector assembly consists of three rings of 8 detector modules. The transaxial field of view (FOV) has a diameter of 80 mm and the axial FOV is 148 mm. A NEMA NU-4 image quality phantom (Data Spectrum Corporation, Durham, USA) having five rods with diameters of 1, 2, 3, 4 and 5 mm and a uniform central region was used. Measurements with {sup 18}F, {sup 68}Ga and {sup 64}Cu were performed in list mode acquisition over 10 h. Data were reconstructed using a maximum-likelihood expectation-maximization (MLEM) algorithm with iteration numbers between 5 and 50. System sensitivity, count rate linearity, convergence and recovery coefficients were analyzed. The sensitivities for the entire FOV (non-NEMA method) for {sup 18}F, {sup 68}Ga and {sup 64}Cu were (3.78 ± 0.05)%, (3.97 ± 0.18)% and (3.79 ± 0.37)%, respectively. The sensitivity based on the NEMA protocol using the {sup 22}Na point source yielded (5.53 ± 0.06)%. Dead-time corrected true counts were linear for activities ≤7 MBq ({sup 18}F and {sup 68}Ga) and ≤17 MBq ({sup 64}Cu) in the phantom. The radial, tangential and axial full widths at half maximum (FWHMs) were 1.52, 1.47 and 1.48 mm. Recovery coefficients for the uniform region with a total activity of 8 MBq in the phantom were (0.97 ± 0.05), (0.98 ± 0.06), (0.98 ± 0.06) for {sup 18}F, {sup 68}Ga and {sup 64}Cu, respectively. The Albira II pre-clinical PET system has an adequate sensitivity range and the system linearity is suitable for the range of activities used for pre-clinical imaging. Overall, the system showed a favorable image

  16. MRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals

    Science.gov (United States)

    Cai, Liang; Lai, Xiaochun; Shen, Zengming; Chen, Chin-Tu; Meng, Ling-Jian

    2014-01-01

    In this paper, we will report the development of an ultrahigh resolution MR-compatible SPECT system that can be operated inside a pre-existing clinical MR scanner for simultaneous dual-modality imaging of small animals. This system is constructed with 40 small-pixel CdTe detector modules assembled in a fully stationary ring SPECT geometry. We have experimentally demonstrated that this system is capable of providing an imaging resolution of <500 μm when operating inside MR scanners. We will report the design, construction of the MRI-compatible SPECT system, including the detector technology, collimator, system development and so on. The first imaging results obtained with this newly constructed SPECT system will also be reported.

  17. MRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals.

    Science.gov (United States)

    Cai, Liang; Lai, Xiaochun; Shen, Zengming; Chen, Chin-Tu; Meng, Ling-Jian

    2014-01-11

    In this paper, we will report the development of an ultrahigh resolution MR-compatible SPECT system that can be operated inside a pre-existing clinical MR scanner for simultaneous dual-modality imaging of small animals. This system is constructed with 40 small-pixel CdTe detector modules assembled in a fully stationary ring SPECT geometry. We have experimentally demonstrated that this system is capable of providing an imaging resolution of <500 μm when operating inside MR scanners. We will report the design, construction of the MRI-compatible SPECT system, including the detector technology, collimator, system development and so on. The first imaging results obtained with this newly constructed SPECT system will also be reported.

  18. Effects of casoxin 4 on morphine inhibition of small animal intestinal contractility and gut transit in the mouse

    Directory of Open Access Journals (Sweden)

    Glen S Patten

    2011-02-01

    Full Text Available Glen S Patten1,2, Richard J Head1, Mahinda Y Abeywardena1,21CSIRO Preventative Health National Research Flagship, Adelaide, Australia; 2CSIRO Food and Nutritional Sciences, Adelaide, AustraliaBackground and aims: Chronic opioid analgesia has the debilitating side-effect of constipation in human patients. The major aims of this study were to: 1 characterize the opioid-specific antagonism of morphine-induced inhibition of electrically driven contraction of the small intestine of mice, rats, and guinea pigs; and 2 test if the oral delivery of small milk-derived opioid antagonist peptides could block morphine-induced inhibition of intestinal transit in mice.Methods: Mouse, rat, and guinea pig intact ileal sections were electrically stimulated to contract and inhibited with morphine in vitro. Morphine inhibition was then blocked by opioid subtype antagonists in the mouse and guinea pig. Using a polymeric dye, Poly R-478, the opioid antagonists casoxin 4 and lactoferroxin A were tested orally for blocking activity of morphine inhibition of gut transit in vivo by single or double gavage techniques.Results: The guinea pig tissue was more sensitive to morphine inhibition compared with the mouse or the rat (IC50 [half maximal inhibitory concentration] values as nmol/L ± SEM were 34 ± 3, 230 ± 13, and 310 ± 14 respectively (P < 0.01. The inhibitory influence of opioid agonists (IC50 in electrically driven ileal mouse preparations were DADLE ([D-Ala2, D-Leu5]-enkephalin ≥ met-enkephalin ≥ dynorphin A ≥ DAMGO ([D-Ala2, N-Me-Phe4, Gly-ol5]-enkephalin > morphine > morphiceptin as nmol/L 13.9, 17.3, 19.5, 23.3, 230, and 403 respectively. The mouse demonstrated predominantly Κ- and δ-opioid receptor activity with a smaller µ-opioid receptor component. Both mouse and guinea pig tissue were sensitive to casoxin 4 antagonism of morphine inhibition of contraction. In contrast to naloxone, relatively high oral doses of the µ-opioid receptor antagonists

  19. Development and Operation of a High Resolution Positron Emission Tomography System to Perform Metabolic Studies on Small Animals.

    Science.gov (United States)

    Hogan, Matthew John

    A positron emission tomography system designed to perform high resolution imaging of small volumes has been characterized. Two large area planar detectors, used to detect the annihilation gamma rays, formed a large aperture stationary positron camera. The detectors were multiwire proportional chambers coupled to high density lead stack converters. Detector efficiency was 8%. The coincidence resolving time was 500 nsec. The maximum system sensitivity was 60 cps/(mu)Ci for a solid angle of acceptance of 0.74(pi) St. The maximum useful coincidence count rate was 1500 cps and was limited by electronic dead time. Image reconstruction was done by performing a 3-dimensional deconvolution using Fourier transform methods. Noise propagation during reconstruction was minimized by choosing a 'minimum norm' reconstructed image. In the stationary detector system (with a limited angle of acceptance for coincident events) statistical uncertainty in the data limited reconstruction in the direction normal to the detector surfaces. Data from a rotated phantom showed that detector rotation will correct this problem. Resolution was 4 mm in planes parallel to the detectors and (TURN)15 mm in the normal direction. Compton scattering of gamma rays within a source distribution was investigated using both simulated and measured data. Attenuation due to scatter was as high as 60%. For small volume imaging the Compton background was identified and an approximate correction was performed. A semiquantitative blood flow measurement to bone in the leg of a cat using the ('18)F('-) ion was performed. The results were comparable to investigations using more conventional techniques. Qualitative scans using ('18)F labelled deoxy -D-glucose to assess brain glucose metabolism in a rhesus monkey were also performed.

  20. P.I.X.S.C.A.N.: a micro-CT scanner for small animal based on hybrid pixel detectors

    International Nuclear Information System (INIS)

    Khoury, R.

    2008-03-01

    Since more than a dozen years, efforts were led in the field of X-ray tomography for small animals, principally for the improvement of spatial resolution and the diminution of the absorbed dose. The C.P.P.M. developed the micro-CT P.I.X.S.C.A.N. based on the hybrid pixel detector X.P.A.D.2. In this context, my thesis work consists in studying the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 and the contribution of the hybrid pixels in the imaging of small animals. A fast analytical simulation, FastSimu, was developed. An extrapolation of the performance of the demonstrator P.I.X.S.C.A.N, as well as the validation of the results obtained with the measured data, were led by means of the analytical simulator FastSimu. The demonstrator P.I.X.S.C.A.N./X.P.A.D.2 allowed to obtain reconstructed images with a rather good quality for a relatively weak absorbed dose. Its spatial resolution is degraded by the high number of defective pixels of the detector X.P.A.D.2. Beyond this study, a new version of the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 is under construction. This latter, characterized by two and a half times smaller pixels and about no defective pixels will bring a considerable improvement on spatial resolution. (author)

  1. High Resolution 125I Pinhole SPECT Imaging of the Mouse Thyroid With the MediSPECT Small Animal CdTe Scanner

    Science.gov (United States)

    Mettivier, Giovanni; Montesi, Maria Cristina; Curion, Assunta Simona; Lauria, Adele; Marotta, Marcello; Russo, Paolo

    2010-06-01

    The first in vivo tomographic 125I imaging of the mouse thyroid carried out with the new MediSPECT small animal SPECT scanner is presented. The scanner is based on a fine pitch CdTe semiconductor pixel detector (14 × 14 mm2, 256 × 256 square pixel with a 55 m side) and equipped with a set of high resolution collimators. The collimation and detection units of the scanner are mounted on a gantry, rotating around a horizontal axis, along which is placed the small animal housing. In an in vivo test, the mouse was injected with a Na125 I solution having a total activity of 31.8 MBq. The planar projections for SPECT reconstruction were acquired with a 300 m pinhole (magnification 1.47 and field of view of 9.6 × 9.6 mm2). The projections were captured in a step-and-shoot fashion and were processed with an Ordered Subsets-Expectation Maximization reconstruction algorithm in order to obtain the SPECT images. Several 125I imaging tests have been made by using phantoms to assess the detector spatial resolution. The measured spatial resolution with a 300 m pinhole is about 0.5 mm in planar imaging and better than 1 mm in tomographic imaging.

  2. Preclinical Testing of Antihuman CD28 Fab' Antibody in a Novel Nonhuman Primate Small Animal Rodent Model of Xenogenic Graft-Versus-Host Disease.

    Science.gov (United States)

    Hippen, Keli L; Watkins, Benjamin; Tkachev, Victor; Lemire, Amanda M; Lehnen, Charles; Riddle, Megan J; Singh, Karnail; Panoskaltsis-Mortari, Angela; Vanhove, Bernard; Tolar, Jakub; Kean, Leslie S; Blazar, Bruce R

    2016-12-01

    Graft-versus-host disease (GVHD) is a severe complication of hematopoietic stem cell transplantation. Current therapies to prevent alloreactive T cell activation largely cause generalized immunosuppression and may result in adverse drug, antileukemia and antipathogen responses. Recently, several immunomodulatory therapeutics have been developed that show efficacy in maintaining antileukemia responses while inhibiting GVHD in murine models. To analyze efficacy and better understand immunological tolerance, escape mechanisms, and side effects of clinical reagents, testing of species cross-reactive human agents in large animal GVHD models is critical. We have previously developed and refined a nonhuman primate (NHP) large animal GVHD model. However, this model is not readily amenable to semi-high throughput screening of candidate clinical reagents. Here, we report a novel, optimized NHP xenogeneic GVHD (xeno-GVHD) small animal model that recapitulates many aspects of NHP and human GVHD. This model was validated using a clinically available blocking, monovalent anti-CD28 antibody (FR104) whose effects in a human xeno-GVHD rodent model are known. Because human-reactive reagents may not be fully cross-reactive or effective in vivo on NHP immune cells, this NHP xeno-GVHD model provides immunological insights and direct testing on NHP-induced GVHD before committing to the intensive NHP studies that are being increasingly used for detailed evaluation of new immune therapeutic strategies before human trials.

  3. The emerging role of veterinary orthotics and prosthetics (V-OP) in small animal rehabilitation and pain management.

    Science.gov (United States)

    Mich, Patrice M

    2014-03-01

    In veterinary school, we learn much about how to repair bone fractures, ligament injuries, and neuropathies. The idea, of course, is to return some level of function to a damaged appendage and decrease pain. When a limb cannot be salvaged for medical or financial reasons, we are taught that dogs and cats do "great" on 3 legs. Three legs may mean a less functional limb or outright total amputation. We espouse this doctrine to our clients. Indeed, most of us have countless stories of triped patients acclimating to their disability with aplomb. Although it is true that many patients adapt, learning to ambulate and negotiate their environment, this is functional adaptation-not necessarily the highest quality of life. As a profession, we have come to expect-even accept-that limited mobility, limb breakdown, and chronic neck or back pain are unavoidable consequences. The short- and long-term consequences of limb loss or altered limb function are not benign as once thought. Furthermore, the quality of care demanded by clients is rising and the breadth of knowledge afforded by technology and global communication spawns innovative therapies readily accessible to the computer-savvy pet owner. Recent examples of therapeutic innovations include the following: dentistry, acupuncture, chiropractic, and rehabilitation. Often there is no precedent for these new therapies in animals, and the onus rests with the veterinary community to educate itself to provide best care for patients and clients and to establish evidence-informed best practice. The newest emerging therapeutic modality is veterinary orthotics and prosthetics. Like the previously mentioned modalities, the origin lies in human health care and subsequently leaps to veterinary health care. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Small-animal PET imaging of the type 1 and type 2 cannabinoid receptors in a photothrombotic stroke model

    Energy Technology Data Exchange (ETDEWEB)

    Vandeputte, Caroline; Casteels, Cindy; Koole, Michel; Gerits, Anneleen [KU Leuven, Division of Nuclear Medicine, Leuven (Belgium); KU Leuven, Molecular Small Animal Imaging Center, MoSAIC, Leuven (Belgium); Struys, Tom [Hasselt University, Laboratory of Histology, Biomedical Research Institute, Hasselt (Belgium); KU Leuven, Biomedical NMR Unit, Leuven (Belgium); Veghel, Daisy van; Evens, Nele; Bormans, Guy [KU Leuven, Molecular Small Animal Imaging Center, MoSAIC, Leuven (Belgium); KU Leuven, Laboratory of Radiopharmacy, Leuven (Belgium); Dresselaers, Tom; Himmelreich, Uwe [KU Leuven, Molecular Small Animal Imaging Center, MoSAIC, Leuven (Belgium); KU Leuven, Biomedical NMR Unit, Leuven (Belgium); Lambrichts, Ivo [Hasselt University, Laboratory of Histology, Biomedical Research Institute, Hasselt (Belgium); Laere, Koen van [KU Leuven, Division of Nuclear Medicine, Leuven (Belgium); KU Leuven, Molecular Small Animal Imaging Center, MoSAIC, Leuven (Belgium); UZ Leuven, Division of Nuclear Medicine, Leuven (Belgium)

    2012-11-15

    Recent ex vivo and pharmacological evidence suggests involvement of the endocannabinoid system in the pathophysiology of stroke, but conflicting roles for type 1 and 2 cannabinoid receptors (CB{sub 1} and CB{sub 2}) have been suggested. The purpose of this study was to evaluate CB{sub 1} and CB{sub 2} receptor binding over time in vivo in a rat photothrombotic stroke model using PET. CB{sub 1} and CB{sub 2} microPET imaging was performed at regular time-points up to 2 weeks after stroke using [{sup 18}F]MK-9470 and [{sup 11}C]NE40. Stroke size was measured using MRI at 9.4 T. Ex vivo validation was performed via immunostaining for CB{sub 1} and CB{sub 2}. Immunofluorescent double stainings were also performed with markers for astrocytes (GFAP) and macrophages/microglia (CD68). [{sup 18}F]MK-9470 PET showed a strong increase in CB{sub 1} binding 24 h and 72 h after stroke in the cortex surrounding the lesion, extending to the insular cortex 24 h after surgery. These alterations were consistently confirmed by CB{sub 1} immunohistochemical staining. [{sup 11}C]NE40 did not show any significant differences between stroke and sham-operated animals, although staining for CB{sub 2} revealed minor immunoreactivity at 1 and 2 weeks after stroke in this model. Both CB{sub 1} {sup +} and CB{sub 2} {sup +} cells showed minor immunoreactivity for CD68. Time-dependent and regionally strongly increased CB{sub 1}, but not CB{sub 2}, binding are early consequences of photothrombotic stroke. Pharmacological interventions should primarily aim at CB{sub 1} signalling as the role of CB{sub 2} seems minor in the acute and subacute phases of stroke. (orig.)

  5. Test–retest repeatability of quantitative cardiac 11C-meta-hydroxyephedrine measurements in rats by small animal positron emission tomography

    International Nuclear Information System (INIS)

    Thackeray, James T.; Renaud, Jennifer M.; Kordos, Myra; Klein, Ran; Kemp, Robert A. de; Beanlands, Rob S.B.; DaSilva, Jean N.

    2013-01-01

    Introduction: The norepinephrine analogue 11 C-meta-hydroxyephedrine (HED) has been used to interrogate sympathetic neuronal reuptake in cardiovascular disease. Application for longitudinal studies in small animal models of disease necessitates an understanding of test–retest variability. This study evaluated the repeatability of multiple quantitative cardiac measurements of HED retention and washout and the pharmacological response to reuptake blockade and enhanced norepinephrine levels. Methods: Small animal PET images were acquired over 60 min following HED administration to healthy male Sprague Dawley rats. Paired test and retest scans were undertaken in individual animals over 7 days. Additional HED scans were conducted following administration of norepinephrine reuptake inhibitor desipramine or continuous infusion of exogenous norepinephrine. HED retention was quantified by retention index, standardized uptake value (SUV), monoexponential and one-compartment washout. Plasma and cardiac norepinephrine were measured by high performance liquid chromatography. Results: Test retest variability was lower for retention index (15% ± 12%) and SUV (19% ± 15%) as compared to monoexponential washout rates (21% ± 13%). Desipramine pretreatment reduced myocardial HED retention index by 69% and SUV by 85%. Chase treatment with desipramine increased monoexponential HED washout by 197% compared to untreated controls. Norepinephrine infusion dose-dependently reduced HED accumulation, reflected by both retention index and SUV, with a corresponding increase in monoexponential washout. Plasma and cardiac norepinephrine levels correlated with HED quantitative measurements. Conclusion: The repeatability of HED retention index, SUV, and monoexponential washout supports its suitability for longitudinal PET studies in rats. Uptake and washout of HED are sensitive to acute increases in norepinephrine concentration

  6. Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies

    Science.gov (United States)

    Marinetto, Eugenio; Pascau, Javier; Desco, Manuel

    2014-01-01

    Purpose Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. Methods We propose a novel B-spline-based compressed sensing method (SPLICS) that includes motion estimation and generalizes previous spatiotemporal total variation (ST-TV) methods by taking into account motion between frames. In addition, we assess the effect of an optimum weighting between spatial and temporal sparsity to further improve results. Both methods were implemented using the efficient Split Bregman methodology and were evaluated on rat data comparing animals with myocardial infarction with controls for several acceleration factors. Results ST-TV with optimum selection of the weighting sparsity parameter led to results similar to those of SPLICS; ST-TV with large relative temporal sparsity led to temporal blurring effects. However, SPLICS always properly corrected temporal blurring, independently of the weighting parameter. At acceleration factors of 15, SPLICS did not distort temporal intensity information but led to some artefacts and slight over-smoothing. At an acceleration factor of 7, images were reconstructed without significant loss of quality. Conclusion We have validated SPLICS for retrospective cardiac cine in small animal, achieving high acceleration factors. In addition, we have shown that motion modelling may not be essential for retrospective cine and that similar results can be obtained by using ST-TV provided that an optimum selection of the spatiotemporal sparsity weighting parameter is performed. PMID:25350290

  7. Identification and characterization of methicillin-resistant Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus haemolyticus and Staphylococcus pettenkoferi from a small animal clinic.

    Science.gov (United States)

    Weiss, Sonja; Kadlec, Kristina; Fessler, Andrea T; Schwarz, Stefan

    2013-12-27

    The aim of this study was to isolate and characterize methicillin-resistant staphylococci (MRS) in a small animal clinic and to investigate their distribution and possible transmission. Swabs (n=72) were taken from hospitalized pets, the environment and employees of a small animal clinic and screened for the presence of MRS. The staphylococcal species was confirmed biochemically or by 16S rDNA sequencing. Susceptibility to antimicrobial agents was tested by broth dilution. The presence of mecA and other resistance genes was confirmed by PCR. Molecular typing of the isolates followed standard procedures. In total, 34 MRS belonging to the four species Staphylococcus aureus (n=5), Staphylococcus epidermidis (n=21), Staphylococcus haemolyticus (n=6) or Staphylococcus pettenkoferi (n=2) were isolated. All isolates were multidrug-resistant with resistance to at least three classes of antimicrobial agents. Among the five methicillin-resistant S. aureus (MRSA) isolates, four belonged to the clonal complex CC398; two of them were isolated from cats, the remaining two from pet cages. Overall, the MRS isolates differed in their characteristics, except for one S. epidermidis clone (n=9) isolated from hospitalized cats without clinical staphylococcal infections, pet cages, the clinic environment as well as from a healthy employee. This MRSE clone was resistant to 10 classes of antimicrobial agents, including aminocyclitols, β-lactams, fluoroquinolones, lincosamides, macrolides, phenicols, pleuromutilins, sulfonamides, tetracyclines and trimethoprim. These findings suggest a possible transmission of specific MRS isolates between animal patients, employees and the clinic environment. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development and applications of TOHR, an original emission tomography system, adapted to small animals; Developpement et applications de TOHR, un systeme original de tomographie d`emission, adapte au petit animal

    Energy Technology Data Exchange (ETDEWEB)

    Ploux, Lydie [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1997-12-11

    For many neuro-biological studies, it is necessary to link microscopic aspects of the brain`s organization with integrated brain functions. Details of the former are obtained by in vitro and in situ molecular biology techniques, whereas the latter are acquired through behavioural studies. In vivo radio-imaging methods, like emission tomography are the ideal tools to investigate the links between these two levels of brain organization. The work which is presented here focuses on a new approach of emission tomography adapted to small animal studies: TOHR (French, acronym for TOmographe Haute Resolution). The principle is based on the use of a large solid angle, high resolution and high efficiency focusing collimator. High resolution and high signal to noise ratio are improved by using nuclides having a two-photon decay with small angular correlation ({sup 125}I, {sup 123}I, {sup 111}In,...). The image is built step-by-step, by moving the animal relative to the collimator focal point. First, numerical simulation showed the possibility of reaching sub-millimetric resolutions; these results led to the collimator geometry (at present 10 over the 20 faces of an icosahedron, 15 faces in the future). Then, a prototype of TOHR has been built and characterized. Its performance is very close to the numerical prediction: spatial resolution of 1.4 mm and detection efficiency 0.64%. Finally, experiments on a rat thyroid allowed the preparation and realization of the first experiments on a rat striatum. The good quality of these images shows that it is now possible to evaluate TOHR capabilities on a dopaminergic neuron degeneration model in rats in the field of neuro-degenerative disease studies. (author) 51 refs., 76 figs., 28 tabs.

  9. Development of a clear sub-millimeter small animal PET scanner by reducing the influence of the non-collinearity effect

    Science.gov (United States)

    Bolwin, K.; Vernekohl, D.; Lühder, J.; Czekalla, B.; Wessels, J. P.; Schäfers, K. P.

    2017-03-01

    Small animal PET plays a major role in studying molecular processes in vivo. However, the spatial resolution of small animal PET is limited by physical effects like positron range, photon non-collinearity, and object scattering. The aim of this project was to minimize the influence of the non-collinearity effect by reducing the distance between the coincidence detectors leading to an improved spatial resolution. A multi-wire proportional chamber-based high-resolution PET scanner (quadHIDAC) was used, offering a spatial resolution of nearly 1 mm FWHM. By removing two opposite detector banks of the 4-detector-setup, the inner distance between the two remaining detector plates could be reduced from 180 mm to 40 mm. List mode acquisitions of a small point source (22Na) experiment were performed, images were reconstructed (0.25 mm voxel size) using a one-pass list-mode EM algorithm and the FWHM in the radial, tangential, and axial directions was calculated. In addition, a Jaszczak phantom (hole sizes of 0.7 up to 1.2 mm) was acquired with both scanners. The prototype high-resolution PET scanner showed improved spatial resolution in radial (0.9 mm FWHM), tangential (0.9 mm FWHM), and axial (0.8 mm FWHM) direction compared to the quadHIDAC scanner (1.x mm, 1.x mm, 1.x mm), respectively offering clear sub-millimeter imaging. Blurring effects due to photon non-collinearity could be reduced by minimizing the detector distance.

  10. Accuracy and repeatability of long-bone replicas of small animals fabricated by use of low-end and high-end commercial three-dimensional printers.

    Science.gov (United States)

    Cone, Jamie A; Martin, Thomas M; Marcellin-Little, Denis J; Harrysson, Ola L A; Griffith, Emily H

    2017-08-01

    OBJECTIVE To assess the repeatability and accuracy of polymer replicas of small, medium, and large long bones of small animals fabricated by use of 2 low-end and 2 high-end 3-D printers. SAMPLE Polymer replicas of a cat femur, dog radius, and dog tibia were fabricated in triplicate by use of each of four 3-D printing methods. PROCEDURES 3-D renderings of the 3 bones reconstructed from CT images were prepared, and length, width of the proximal aspect, and width of the distal aspect of each CT image were measured in triplicate. Polymer replicas were fabricated by use of a high-end system that relied on jetting of curable liquid photopolymer, a high-end system that relied on polymer extrusion, a triple-nozzle polymer extrusion low-end system, and a dual-nozzle polymer extrusion low-end system. Polymer replicas were scanned by use of a laser-based coordinate measurement machine. Length, width of the proximal aspect, and width of the distal aspect of the scans of replicas were measured and compared with measurements for the 3-D renderings. RESULTS 129 measurements were collected for 34 replicas (fabrication of 1 large long-bone replica was unsuccessful on each of the 2 low-end printers). Replicas were highly repeatable for all 3-D printers. The 3-D printers overestimated dimensions of large replicas by approximately 1%. CONCLUSIONS AND CLINICAL RELEVANCE Low-end and high-end 3-D printers fabricated CT-derived replicas of bones of small animals with high repeatability. Replicas were slightly larger than the original bones.

  11. DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators

    Science.gov (United States)

    España, Samuel; Marcinkowski, Radoslaw; Keereman, Vincent; Vandenberghe, Stefaan; Van Holen, Roel

    2014-07-01

    A new preclinical PET system based on dSiPMs, called DigiPET, is presented. The system is based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low-cost compared to systems based on pixelated crystals. Current dedicated small-rodent PET scanners have a spatial resolution in the order of 1 mm. Most of them have a large footprint, requiring considerable laboratory space. For rodent brain imaging, a PET scanner with sub-millimeter resolution is desired. To achieve this, crystals with a pixel pitch down to 0.5 mm have been used. However, fine pixels are difficult to produce and will render systems expensive. In this work, we present the first results with a high-resolution preclinical PET scanner based on thin monolithic scintillators and a large solid angle. The design is dedicated to rat-brain imaging and therefore has a very compact geometry. Four detectors were placed in a square arrangement with a distance of 34.5 mm between two opposing detector modules, defining a field of view (FOV) of 32 × 32 × 32 mm3. Each detector consists of a thin monolithic LYSO crystal of 32 × 32 × 2 mm3 optically coupled to a digital silicon photomultiplier (dSiPM). Event positioning within each detector was obtained using the maximum likelihood estimation (MLE) method. To evaluate the system performance, we measured the energy resolution, coincidence resolving time (CRT), sensitivity and spatial resolution. The image quality was evaluated by acquiring a hot-rod phantom filled with 18F-FDG and a rat head one hour after an 18F-FDG injection. The MLE yielded an average intrinsic spatial resolution on the detector of 0.54 mm FWHM. We obtained a CRT of 680 ps and an energy resolution of 18% FWHM at 511 keV. The sensitivity and spatial resolution obtained at the center of the FOV were 6.0 cps kBq-1 and 0.7 mm, respectively. In the reconstructed images of the hot-rod phantom, hot rods down to 0.7 mm can be discriminated. In conclusion, a compact PET

  12. Using Rose's metal alloy as a pinhole collimator material in preclinical small-animal imaging: a Monte Carlo evaluation.

    Science.gov (United States)

    Peterson, Mikael; Strand, Sven-Erik; Ljungberg, Michael

    2015-04-01

    most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For (125)I, the difference in spatial resolution between gold and Rose's metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose's metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.

  13. DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators

    International Nuclear Information System (INIS)

    España, Samuel; Marcinkowski, Radoslaw; Keereman, Vincent; Vandenberghe, Stefaan; Van Holen, Roel

    2014-01-01

    A new preclinical PET system based on dSiPMs, called DigiPET, is presented. The system is based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low-cost compared to systems based on pixelated crystals. Current dedicated small-rodent PET scanners have a spatial resolution in the order of 1 mm. Most of them have a large footprint, requiring considerable laboratory space. For rodent brain imaging, a PET scanner with sub-millimeter resolution is desired. To achieve this, crystals with a pixel pitch down to 0.5 mm have been used. However, fine pixels are difficult to produce and will render systems expensive. In this work, we present the first results with a high-resolution preclinical PET scanner based on thin monolithic scintillators and a large solid angle. The design is dedicated to rat-brain imaging and therefore has a very compact geometry. Four detectors were placed in a square arrangement with a distance of 34.5 mm between two opposing detector modules, defining a field of view (FOV) of 32 × 32 × 32 mm 3 . Each detector consists of a thin monolithic LYSO crystal of 32 × 32 × 2 mm 3  optically coupled to a digital silicon photomultiplier (dSiPM). Event positioning within each detector was obtained using the maximum likelihood estimation (MLE) method. To evaluate the system performance, we measured the energy resolution, coincidence resolving time (CRT), sensitivity and spatial resolution. The image quality was evaluated by acquiring a hot-rod phantom filled with 18 F-FDG and a rat head one hour after an 18 F-FDG injection. The MLE yielded an average intrinsic spatial resolution on the detector of 0.54 mm FWHM. We obtained a CRT of 680 ps and an energy resolution of 18% FWHM at 511 keV. The sensitivity and spatial resolution obtained at the center of the FOV were 6.0 cps kBq −1  and 0.7 mm, respectively. In the reconstructed images of the hot-rod phantom, hot rods down to 0.7 mm can be discriminated

  14. Take Only Photographs, Leave Only Footprints: Novel Applications of Non-Invasive Survey Methods for Rapid Detection of Small, Arboreal Animals.

    Directory of Open Access Journals (Sweden)

    Cheryl A Mills

    Full Text Available The development of appropriate wildlife survey techniques is essential to promote effective and efficient monitoring of species of conservation concern. Here, we demonstrate the utility of two rapid-assessment, non-invasive methods to detect the presence of elusive, small, arboreal animals. We use the hazel dormouse, Muscardinus avellanarius, a rodent of conservation concern, as our focal species. Prevailing hazel dormouse survey methods are prolonged (often taking months to years to detect dormice, dependent on season and habitat, and/or have low detection rates. Alternatives would be of great use to ecologists who undertake dormouse surveys, especially those assessing the need for mitigation measures, as legally required for building development projects. Camera traps and footprint tracking are well-established tools for monitoring elusive large terrestrial mammals, but are rarely used for small species such as rodents, or in arboreal habitats. In trials of these adapted methods, hazel dormice visited bait stations and were successfully detected by both camera traps and tracking equipment at each of two woodland study sites, within days to weeks of installation. Camera trap images and footprints were of adequate quality to allow discrimination between two sympatric small mammal species (hazel dormouse and wood mouse, Apodemus sylvaticus. We discuss the relative merits of these methods with respect to research aims, funds, time available and habitat.

  15. Take Only Photographs, Leave Only Footprints: Novel Applications of Non-Invasive Survey Methods for Rapid Detection of Small, Arboreal Animals.

    Science.gov (United States)

    Mills, Cheryl A; Godley, Brendan J; Hodgson, David J

    2016-01-01

    The development of appropriate wildlife survey techniques is essential to promote effective and efficient monitoring of species of conservation concern. Here, we demonstrate the utility of two rapid-assessment, non-invasive methods to detect the presence of elusive, small, arboreal animals. We use the hazel dormouse, Muscardinus avellanarius, a rodent of conservation concern, as our focal species. Prevailing hazel dormouse survey methods are prolonged (often taking months to years to detect dormice), dependent on season and habitat, and/or have low detection rates. Alternatives would be of great use to ecologists who undertake dormouse surveys, especially those assessing the need for mitigation measures, as legally required for building development projects. Camera traps and footprint tracking are well-established tools for monitoring elusive large terrestrial mammals, but are rarely used for small species such as rodents, or in arboreal habitats. In trials of these adapted methods, hazel dormice visited bait stations and were successfully detected by both camera traps and tracking equipment at each of two woodland study sites, within days to weeks of installation. Camera trap images and footprints were of adequate quality to allow discrimination between two sympatric small mammal species (hazel dormouse and wood mouse, Apodemus sylvaticus). We discuss the relative merits of these methods with respect to research aims, funds, time available and habitat.

  16. Vacina antivariólica: seu primeiro século no Brasil (da vacina jenneriana à animal The small pox vaccine: its first century in Brazil (from the Jennerian to the animal vaccine

    Directory of Open Access Journals (Sweden)

    Tania Fernandes

    1999-06-01

    Full Text Available Neste artigo abordamos aspectos da institucionalização da vacina antivariólica no Brasil, em cerca de um século. Apresentamos descobertas e discussões ocorridas em outros países, mostrando seus reflexos em nosso país desde a introdução da vacina humanizada até a chegada da vacina animal e a criação do Instituto Vacínico Municipal, por iniciativa particular do dr. Pedro Affonso Franco, o barão de Pedro Affonso. A introdução da vacina animal significou um avanço no controle da doença e impulsionou as discussões que redundaram no alinhamento de grupos médicos e políticos em torno de Oswaldo Cruz ou do barão de Pedro Affonso. Com a incorporação do Instituto Vacínico aos laboratórios de Manguinhos, terminou a polêmica que agitou os meios acadêmicos e políticos.Covering a period of roughly hundred years, the article looks at some of the more meaningful events during the period in which the small pox vaccine was institutionalized in Brazil. Discoveries and discussions then taking place in other countries are also examined, particularly as they influenced Brazil. The process is followed from introduction of the human vaccine to the arrival of the animal vaccine and creation of the Municipal Vaccine Institute - a private initiative by physician Pedro Affonso Franco, also known as the barão de Pedro Affonso. Adoption of the animal vaccine not only represented progress in controlling the disease but also spurred discussions that saw medical and political groups in Brazil taking sides with either Oswaldo Cruz or the barão de Pedro Affonso. The debate continued within the academic and political arenas until the Vaccine Institute was made part of the Manguinhos laboratories.

  17. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.

    Science.gov (United States)

    Kuang, Zhonghua; Sang, Ziru; Wang, Xiaohui; Fu, Xin; Ren, Ning; Zhang, Xianming; Zheng, Yunfei; Yang, Qian; Hu, Zhanli; Du, Junwei; Liang, Dong; Liu, Xin; Zheng, Hairong; Yang, Yongfeng

    2018-02-01

    The performance of current small animal PET scanners is mainly limited by the detector performance and depth encoding detectors are required to develop PET scanner to simultaneously achieve high spatial resolution and high sensitivity. Among all depth encoding PET detector approaches, dual-ended readout detector has the advantage to achieve the highest depth of interaction (DOI) resolution and spatial resolution. Silicon photomultiplier (SiPM) is believed to be the photodetector of the future for PET detector due to its excellent properties as compared to the traditional photodetectors such as photomultiplier tube (PMT) and avalanche photodiode (APD). The purpose of this work is to develop high resolution depth encoding small animal PET detector using dual-ended readout of finely pixelated scintillator arrays with SiPMs. Four lutetium-yttrium oxyorthosilicate (LYSO) arrays with 11 × 11 crystals and 11.6 × 11.6 × 20 mm 3 outside dimension were made using ESR, Toray and BaSO 4 reflectors. The LYSO arrays were read out with Hamamatsu 4 × 4 SiPM arrays from both ends. The SiPM array has a pixel size of 3 × 3 mm 2 , 0.2 mm gap in between the pixels and a total active area of 12.6 × 12.6 mm 2 . The flood histograms, DOI resolution, energy resolution and timing resolution of the four detector modules were measured and compared. All crystals can be clearly resolved from the measured flood histograms of all four arrays. The BaSO 4 arrays provide the best and the ESR array provides the worst flood histograms. The DOI resolution obtained from the DOI profiles of the individual crystals of the four array is from 2.1 to 2.35 mm for events with E > 350 keV. The DOI ratio variation among crystals is bigger for the BaSO 4 arrays as compared to both the ESR and Toray arrays. The BaSO 4 arrays provide worse detector based DOI resolution. The photopeak amplitude of the Toray array had the maximum change with depth, it provides the worst energy resolution of

  18. Optimization and evaluation of Flexicult(®) Vet for detection, identification and antimicrobial susceptibility testing of bacterial uropathogens in small animal veterinary practice

    DEFF Research Database (Denmark)

    Guardabassi, Luca; Hedberg, Sandra; Jessen, Lisbeth Rem

    2015-01-01

    -pathogens in veterinary practice. METHODS: Seventy-two urine samples from dogs and cats with suspected UTI presenting to seven veterinary facilities were used by clinical staff and an investigator to estimate sensitivity and specificity of Flexicult Vet A compared to laboratory reference standards for culture...... B (commercial name Flexicult(®) Vet) is a time- and cost-effective point-of-care test to guide antimicrobial choice and facilitate implementation of antimicrobial use guidelines for treatment of UTIs in small animals, provided that clinical staff is adequately trained to interpret the results...... and susceptibility testing. Subsequently, the test was modified by inclusion of an oxacillin-containing compartment for detection of methicillin-resistant staphylococci. The performance of the modified product (Flexicult Vet B) for susceptibility testing was evaluated in vitro using a collection of 110 clinical...

  19. Optimized time