WorldWideScience

Sample records for treating industrial wastewater

  1. Performance evaluation of membrane bioreactor for treating industrial wastewater: A case study in Isfahan Mourchekhurt industrial estate

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Amin

    2016-01-01

    Conclusion: The MBR technology was used to treat the combined industrial wastewater was efficient, and its effluent can be perfectly used for water reuse. The MBR performance was improved by applying an anaerobic pretreatment unit.

  2. Drip irrigation with treated wastewater from cashew nut industry under service pressures

    Directory of Open Access Journals (Sweden)

    Ketson Bruno da Silva

    2014-02-01

    Full Text Available The agricultural use of wastewater generated in the processing of cashew nuts enables the rationalization of water use, as well as the minimization of pollution and environmental degradation. The study aimed to analyze the effect of service pressures in the distribution uniformity of drip irrigation units applying treated wastewater from cashew nut industry. The experiment was conducted in split-split plots scheme having the service pressures (70, 140, 210 and 280 kPa on parcels, the emitters models (G1, G2 and G3 on subplots and the evaluation periods (0, 20, 40, 60, 80, 100, 120, 140 and 160 h of operation of the irrigation units on subsubplots. The treatments were distributed in a completely randomized design with three replications. The coefficient of uniformity of distribution of irrigation units, as well as the physical, chemical and microbiological characteristics of the effluent were determined every 20 hours of operation the irrigation units to totalize 160 h. The combination of dripper G3 and service pressure of 140 kPa provided excellent levels of distribution uniformity of effluent on irrigation units operating with treated wastewater of cashew nut industry. For application of treated wastewater from cashew nut it is not recommended the use of drippers with low flow rate (? 1.6 L h-1 and labyrinth of greater length (? 58 mm.

  3. Reduction of organic trace compounds and fresh water consumption by recovery of advanced oxidation processes treated industrial wastewater.

    Science.gov (United States)

    Bierbaum, S; Öller, H-J; Kersten, A; Klemenčič, A Krivograd

    2014-01-01

    Ozone (O(3)) has been used successfully in advanced wastewater treatment in paper mills, other sectors and municipalities. To solve the water problems of regions lacking fresh water, wastewater treated by advanced oxidation processes (AOPs) can substitute fresh water in highly water-consuming industries. Results of this study have shown that paper strength properties are not impaired and whiteness is slightly impaired only when reusing paper mill wastewater. Furthermore, organic trace compounds are becoming an issue in the German paper industry. The results of this study have shown that AOPs are capable of improving wastewater quality by reducing organic load, colour and organic trace compounds.

  4. PERFORMANCE EVALUATION OF AN ANAEROBIC BAFFLED REACTOR TREATING WHEAT FLOUR STARCH INDUSTRY WASTEWATER

    Directory of Open Access Journals (Sweden)

    H. Movahedyan, A. Assadi, A. Parvaresh

    2007-04-01

    Full Text Available Feasibility of the anaerobic baffled reactor process was investigated for the treatment of wheat flour starch wastewater. After removal of suspended solids by simple gravity settling, starch wastewater was used as a feed. Start-up of a reactor (with a volume of 13.5 L and five compartments with diluted feed of approximately 4500 mg/L chemical oxygen demand was accomplished in about 9 weeks using seed sludge from anaerobic digester of municipal wastewater treatment plant. The reactor with hydraulic retention time of 72h at 35°C and initial organic loading rate of 1.2 kgCOD/m3.d showed 61% COD removal efficiency. The best performance of reactor was observed with an organic loading rate of 2.5 kgCOD/m3.d or hydraulic retention time of 2.45 d and the COD conversion of 67% was achieved. The system also showed very high solids retention with effluent suspended solids concentration of about 50 mg/L for most organic and hydraulic loadings studied. Based on these observations, the ABR process has potential to treat food industrial wastewater as a pretreatment and is applicable for extreme environmental conditions.

  5. CFD Simulation of an Anaerobic Membrane BioReactor (AnMBR to Treat Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    Laura C. Zuluaga

    2015-06-01

    Full Text Available A Computational Fluid Dynamics (CFD simulation has been developed for an Anaerobic Membrane BioReactor (AnMBR to treat industrial wastewater. As the process consists of a side-stream MBR, two separate simulations were created: (i reactor and (ii membrane. Different cases were conducted for each one, so the surrounding temperature and the total suspended solids (TSS concentration were checked. For the reactor, the most important aspects to consider were the dead zones and the mixing, whereas for the ceramic membrane, it was the shear stress over the membrane surface. Results show that the reactor's mixing process was adequate and that the membrane presented higher shear stress in the 'triangular' channel.

  6. Assessment of the toxicity of wastewater from the metalworking industry treated using a conventional physico-chemical process.

    Science.gov (United States)

    Machado, Rodrigo Matuella; Monteggia, Luiz Olinto; Arenzon, Alexandre; Curia, Ana Cristina

    2016-06-01

    This article presents results from a toxicity reduction evaluation program intended to describe wastewater from the metalworking industry that was treated using a conventional physico-chemical process. The toxicity of the wastewater for the microcrustacean Daphnia magna was predominantly expressive. Alkaline cyanide wastewater generated from electroplating accounted for the largest number of samples with expressive toxicity. When the raw wastewater concentrations in the batches were repeated, inexpressive toxicity variations were observed more frequently among the coagulated-flocculated samples. At the coagulation-flocculation step, 22.2 % of the treatments had reduced acute toxicity, 30.6 % showed increased toxicity, and 47.2 % remained unchanged. The conductivity and total dissolved solids contents of the wastewater indicated the presence of salts with charges that were inappropriate for the survival of daphnid. The wastewaters treated by neutralization and coagulation-flocculation had average metallic compound contents that were greater than the reference toxic concentrations reported in other studies, suggesting that metals likely contributed to the toxic effects of the wastewater on freshwater microcrustaceans. Thus, alternative coagulants and flocculants should be assessed, and feasible doses should be determined to improve wastewater treatment. In addition, advanced treatment processes should be assessed for their abilities to remove dissolved toxic salts and ions.

  7. The efficiency of electrocoagulation using aluminum electrodesin treating wastewater from a dairy industry

    Directory of Open Access Journals (Sweden)

    Gerson de Freitas Silva Valente

    2015-09-01

    Full Text Available This research deals with the investigation of electrocoagulation (EC treatment of wastewater from a dairy plant using aluminum electrodes. Electrolysis time, pH, current density and distance between electrodes were considered to assess the removal efficiency of chemical oxygen demand (COD, total solids (TS and their fractions and turbidity. Samples were collected from the effluent of a dairy plant using a sampling methodology proportional to the flow. The treatments were applied according to design factorial of half fraction with two levels of treatments and 3 repetitions at the central point. The optimization of parameters for treating dairy industry effluent by electrocoagulation using aluminum electrodes showed that electric current application for 21 minutes, an initial sample pH near 5.0 and a current density of 61.6A m-2 resulted in a significant reduction in COD by 57%; removal of turbidity by 99%, removal of total suspended solids by 92% and volatile suspended solids by 97%; and a final treated effluent pH of approximately 10. Optimum operating condition was used for cost calculations show that operating cost is approximately 3.48R$ m-3.

  8. Wastewater Industrial Contributors

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Industrial contributors to municipal wastewater treatment facilities in Iowa for the National Pollutant Discharge Elimination System (NPDES) program.

  9. The startup performance and microbial distribution of an anaerobic baffled reactor (ABR) treating medium-strength synthetic industrial wastewater.

    Science.gov (United States)

    Jiang, Hao; Nie, Hong; Ding, Jiangtao; Stinner, Walter; Sun, Kaixuan; Zhou, Hongjun

    2018-01-02

    In this study, an anaerobic baffled reactor (ABR) with seven chambers was applied to treat medium-strength synthetic industrial wastewater (MSIW). The performance of startup and shock test on treating MSIW was investigated. During the acclimation process, the chemical oxygen demand (COD) of MSIW gradually increased from 0 to 2,000 mg L -1 , and the COD removal finally reached 90%. At shock test, the feeding COD concentration increased by one-fifth and the reactor adapted very well with a COD removal of 82%. In a stable state, Comamonas, Smithella, Syntrophomonas and Pseudomonas were the main populations of bacteria, while the predominant methanogen was Methanobacterium. The results of chemical and microbiological analysis indicated the significant advantages of ABR, including buffering shocks, separating stages with matching microorganisms and promoting syntrophism. Meanwhile, the strategies for acclimation and operation were of great importance. Further work can test reactor performance in the treatment of actual industrial wastewater.

  10. Matching agricultural freshwater supply and demand: using industrial and domestic treated wastewater for sub-irrigation purposes

    Science.gov (United States)

    Bartholomeus, Ruud; van den Eertwegh, Gé; Worm, Bas; Cirkel, Gijsbert; van Loon, Arnaut; Raat, Klaasjan

    2017-04-01

    Agricultural crop yields depend largely on soil moisture conditions in the root zone. Climate change leads to more prolonged drought periods that alternate with more intensive rainfall events. With unaltered water management practices, reduced crop yield due to drought stress will increase. Therefore, both farmers and water management authorities search for opportunities to manage risks of decreasing crop yields. Available groundwater sources for irrigation purposes are increasingly under pressure due to the regional coexistence of land use functions that are critical to groundwater levels or compete for available water. At the same time, treated wastewater from industries and domestic wastewater treatment plants are quickly discharged via surface waters towards sea. Exploitation of these freshwater sources may be an effective strategy to balance regional water supply and agricultural water demand. We present results of two pilot studies in drought sensitive regions in the Netherlands, concerning agricultural water supply through reuse of industrial and domestic treated wastewater. In these pilots, excess wastewater is delivered to the plant root zone through sub-irrigation by drainage systems. Sub-irrigation is a subsurface irrigation method that can be more efficient than classical, aboveground irrigation methods using sprinkler installations. Domestic wastewater treatment plants in the Netherlands produce annually 40-50mm freshwater. A pilot project has been setup in the eastern part of the Netherlands, in which treated wastewater is applied to a corn field by sub-irrigation during the growing seasons of 2015 and 2016, using a climate adaptive drainage system. The chemical composition of treated domestic wastewater is different from infiltrating excess rainfall water and natural groundwater. In the pilot project, the bromide-chloride ratio and traces of pharmaceuticals in the treated wastewater are used as a tracer to describe water and solute transport in the

  11. Influence of physico-chemical treatment on the subsequent biological process treating paper industry wastewater.

    Science.gov (United States)

    el Khames Saad, Mouhamed; Moussaoui, Younes; Zaghbani, Asma; Mosrati, Imen; Elaloui, Elimame; Ben Salem, Ridha

    2012-01-01

    The present paper presents the main results of the biodegradation study of paper industry wastewater through physico-chemical treatment. Indeed, around 60% of chemical oxygen demand (COD) removal can be achieved by electroflocculation treatment. Furthermore, a removal efficiency of the COD of almost 91% has been obtained by biological treatment, with activated amount of sludge for 24 h of culture. Concerning the physico-chemical pre-treatment of the untreated, filtered and electroflocculated rejection effluents, it has been investigated through the degradation curve of COD studies.

  12. Nitrification in Saline Industrial Wastewater

    NARCIS (Netherlands)

    Moussa, M.S.

    2004-01-01

    Biological nitrogen removal is widely and successfully applied for municipal wastewater. However, these experiences are not directly applicable to industrial wastewater, due to its specific composition. High salt levels in many industrial wastewaters affect nitrification negatively and improved

  13. Characterization of membrane foulants at ambient temperature anaerobic membrane bioreactor treating low-strength industrial wastewater

    DEFF Research Database (Denmark)

    Zarebska, Agata; Kjerstadius, Hamse; Petrinic, Irena

    2016-01-01

    (EDS), Fourier Transform Infrared Spectrometry (ATR-FTIR), Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES), Ion chromatography (IC), zeta potential, and adenosine triphosphate measurements. Based on membrane autopsies, it can be concluded that prevailing fouling is mainly...... the application of the process for the industrial wastewater treatment. In order to solve or reduce the fouling problem it is necessary to have a good insight into the processes that take place both on and in the membrane pores during filtration. Therefore, the objective of this study is to contribute to a better...... of biological and organic origin. SEM observations demonstrated presence of numerous bacteria incorporated with the fouling layer composed of mainly proteins, carbohydrates and lipids as revealed by ATR-FTIR measurements. Furthermore the amounts of ions found by EDS & ICP-OES analysis do not support scaling...

  14. Kinetic rates and mass balance of COD, TKN, and TP using SBR treating domestic and industrial wastewater.

    Science.gov (United States)

    Warodomrungsimun, Chaowalit; Fongsatitkul, Prayoon

    2009-12-01

    To assess the performance of SBR to treat three different types of wastewater from domestic, hospital, slaughterhouse and investigate the kinetic rates of active biomass. Mass balance calculation of COD, TKN and TP was further performed to explain the mechanisms of the biological nutrient removals processed in the SBR system. The measured kinetic rates were in turn used to evaluate the process performances under different types of wastewater. Experimental research involving 3 similar SBR lab-scales were installed and operated at the Sanitary Engineering Laboratory. The reactors were seeded with sludge biomass obtained from the Sri-Phraya Domestic Wastewater Treatment Plant in Bangkok. The slaughterhouse, hospital and domestic wastewaters were treated by SBR system for biological organic carbon (COD), nitrogen (TKN) and phosphorus removals. Biological methods for kinetic rates evaluation were conducted in five replicated batch tests. The removal efficiencies of COD and TKN were greater than 90% for all three types of wastewater while the biological phosphorus removal for domestic and hospital wastewaters were less than 60% and phosphorus removal for slaughterhouse exceeded 95%. The kinetic rates of nitrification and denitrification of hospital wastewater was lower than those the domestic and slaughterhouse wastewaters. Phosphorus release and uptake rates of slaughterhouse wastewater were high but domestic and hospital wastewaters were very low. The result of system removal efficiency and batch test for kinetic rates confirmed that the domestic and hospital wastewaters were in deficiency of organic carbon with respect to its ability to support successful biological phosphorus removal.

  15. Nutrients requirements in biological industrial wastewater treatment ...

    African Journals Online (AJOL)

    Wastewaters from olive mills and pulp and paper mill industries in Jordan have been characterized and treated using laboratory scale anaerobic and aerobic sequencing batch reactors, respectively. Nutrient requirements for these two industrial wastewaters were found to be less than what is usually reported in the literature ...

  16. A combined process to treat lemon industry wastewater and produce biogas

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, A.R.; Rubio, M.C.; Maldonado, M.C. [Quimica y Farmacia, Universidad Nacional de Tucuman, Instituto de Biotecnologia, Facultad de Bioquimica, Ayacucho, Tucuman (Argentina)

    2012-02-15

    We studied a process employed for treating lemon industry effluents, using the macrophyte Eishhornia crassipes (water hyacinth) in a phytoremediation tank with a 6000-L workload. The diluted effluents BOD and COD were reduced to 70 and 61%, respectively, working with a 1.5-h hydraulic residence time (HRT). We investigated the effect of adding every 12 h an inoculum consisting of a consortium of microorganisms isolated from the macrophyte roots and recirculating 30% of the outflow. In this way, we achieved a volumetric removal rate (VRR) of BOD = 354 g/m{sup 3} day. Plants were daily harvested from the tank to maintain growth rate and the density originally planted. We studied their use for biogas production in an anaerobic digester working with 12 and 16 days of hydraulic residence time. The yield obtained was 0.87 L/g and productivity 0.87 L/L day with a loading rate of 5 g/L day. Integrating both processes on an industrial scale would solve the effluent pollution problem and generate an energy source that could be used by the industry itself to lower its production costs. (orig.)

  17. Degradation of organic pollutants and characteristics of activated sludge in an anaerobic/anoxic/oxic reactor treating chemical industrial wastewater

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2014-09-01

    Full Text Available A laboratory-scale anaerobic/anoxic/oxic system operated at the hydraulic retention times (HRT of 20, 40, and 60 h with mixed liquor suspended solids (MLSS concentrations of 3 g/L and 6 g/L was considered for treating chemical industrial wastewater rich in complex organic compounds and total dissolved solids. Extending the HRT and increasing the MLSS concentration resulted in higher removal efficiency for chemical oxygen demand at 72%. Organic compounds in wastewater could be classified into easily-removed and refractory compounds during treatment. The easily-removed compounds consisted primarily of ethers, alcohols, and aldehydes, whereas the refractory compounds included mainly oxygen-containing heterocyclic and benzene-containing compounds. Results from energy-dispersive X-ray spectroscopy showed that several metal ions accumulated in activated sludge, particularly Fe(III. Fe accumulated mainly on the surface of sludge floc pellets and resulted in the compactness of activated sludge, which caused the values of mixed liquor volatile suspended solids /MLSS and sludge volume index to decrease.

  18. Performance evaluation and modeling of a submerged membrane bioreactor treating combined municipal and industrial wastewater using radial basis function artificial neural networks.

    Science.gov (United States)

    Mirbagheri, Seyed Ahmad; Bagheri, Majid; Boudaghpour, Siamak; Ehteshami, Majid; Bagheri, Zahra

    2015-01-01

    Treatment process models are efficient tools to assure proper operation and better control of wastewater treatment systems. The current research was an effort to evaluate performance of a submerged membrane bioreactor (SMBR) treating combined municipal and industrial wastewater and to simulate effluent quality parameters of the SMBR using a radial basis function artificial neural network (RBFANN). The results showed that the treatment efficiencies increase and hydraulic retention time (HRT) decreases for combined wastewater compared with municipal and industrial wastewaters. The BOD, COD, [Formula: see text] and total phosphorous (TP) removal efficiencies for combined wastewater at HRT of 7 hours were 96.9%, 96%, 96.7% and 92%, respectively. As desirable criteria for treating wastewater, the TBOD/TP ratio increased, the BOD and COD concentrations decreased to 700 and 1000 mg/L, respectively and the BOD/COD ratio was about 0.5 for combined wastewater. The training procedures of the RBFANN models were successful for all predicted components. The train and test models showed an almost perfect match between the experimental and predicted values of effluent BOD, COD, [Formula: see text] and TP. The coefficient of determination (R(2)) values were higher than 0.98 and root mean squared error (RMSE) values did not exceed 7% for train and test models.

  19. Feasibility of an Anaerobic Baffled Reactor (ABR In Treating Starch Industry Wastewater

    Directory of Open Access Journals (Sweden)

    Ali Assadi

    2007-03-01

    Full Text Available The anaerobic baffled reactor (ABR includes a mixed anaerobic culture separated into compartments and a novel process with a series of vertical baffles at each compartment. It dose not require granulation for its operation, resulting in shorter start-up time. In this study, the feasibility of the ABR process was investigated for the treatment of wheat flour starch wastewater. Simple gravity settling was used to remove suspended solids from the starch wastewater and used as feed. Start-up of a reactor (13.5L with five compartments using a diluted feed of approximately 4500 mg/L chemical oxygen demand (COD was accomplished in about 9 weeks using seed sludge from the anaerobic digester of a municipal wastewater treatment plant. The reactor with a hydraulic retention time (HRT of 72 h at 35°C and an initial organic loading rate (OLR of 1.2 kgCOD/m3.d showed a removal efficiency of 61% COD. The best reactor performance was observed with an organic loading rate of 2.5 kgCOD/m3.d (or hydraulic retention time of 2.45 d when a COD conversion of 67% was achieved. The main advantage of using an ABR comes from its compartmentalized structure. The first compartment of an ABR may act as a buffer zone to all toxic and inhibitory materials in the feed and, thus, allows the later compartments to be loaded with a relatively harmless, more uniform, and mostly acidified influent. In this respect, the later compartments would be more likely to support active populations of the relatively sensitive methanogenic bacteria.

  20. Biodenitrification of industrial wastewater

    International Nuclear Information System (INIS)

    Donaldson, T.L.; Walker, J.F. Jr.; Helfrich, M.V.

    1987-01-01

    The Feed Materials Production Center (FMPC), a US Department of Energy facility at Fernald, Ohio, is constructing a fluidized-bed biodenitrification plant based on pilot work conducted at the Oak Ridge National Laboratory (ORNL) in the late 1970s and early 1980s. This plant is designed to treat approximately 600 to 800 L/min of wastewater having a nitrate concentration as high as 10 g/L. The effluent is to contain less than 0.1 g/L of nitrate. Since this new facility is an extrapolation of the ORNL work to significantly larger scale equipment and to actual rather than synthetic wastewater, design verification studies have been performed to reduce uncertainties in the scaleup. The results of these studies are summarized in this report. 7 refs., 1 fig

  1. Quantum leap for treating wastewaters

    International Nuclear Information System (INIS)

    Wallace, Paula

    2012-01-01

    Full text: For many Australian food manufacturers there is increasing pressure from government agencies to reach higher standards of wastewater treatment for environmental discharge. In fact, throughout the western wolrd industrual water users are facing a similar challenge. One of the big problems is ageing pipe networks, particularly sewage pipes. Also, industrial wastewaters with high sugar-nutrient loads can cause serious damage to pipelines. This is because fermentation occurs within the wastewater, eroding and degrading the pipes, causing numerous cracks and fractures. This in turn leads to water ingress, which puts a strain on treatment plants because of the higher volume of water, especially in wet weather. Food manufacturing produces large volumes of mostly biodegradable liquid and solid waste. Wastewaters released from food manufacturing can be 'muddy', with high concentrations of suspended solids, fats, oils and grease (FOGs), and, usually, nutrients such as nitrogen. The issue for many food manufacturers is that existing wastewater treatment systems are unable to reduce the nutrient load in the biological treatment stage to a level allowing acceptable discharge. In addition, most rely on large tanks housing bacteria that are submerged in water and aerated. Aeration is energy-hungry and can create a 'sludge-cake' on top of the water, which is difficult to treat. Most existing technologies also use filters, but they foul easily and require ongoing maintenance. According to BioGill chief executive John West, the BioGill technology is groundbreaking and radically different from conventional bioreactors because the 'gills' are not submerged. Instead, the gills, composed of Nano-Ceramic Membrane sheets arranged vertically in pairs, are suspended in the air, above ground, with wastewater travelling down between them. “Fungi and bacteria, known as biomass, grow on the membranes in direct contact with the air, eating nutrients

  2. Industrial wastewater treatment with electron beam

    International Nuclear Information System (INIS)

    Han, Bumsoo; Ko, Jaein; Kim, Jinkyu; Kim, Yuri; Chung, Wooho

    2001-01-01

    Global withdrawals of water to satisfy human demands have grown dramatically in this century. Between 1900 and 1945, water consumption increased by over six times, more than double the rate of population growth. This rapid growth in water demand is due to the increasing reliance on irrigation to achieve food security, the growth of industrial uses, and the increasing use per capita for domestic purposes. Given the seriousness of the situation and future risk of crises, there is an urgent need to develop the water-efficient technologies including economical treatment methods of wastewater and polluted water. In the Central Research Institute of Samsung Heavy Industries (SHI), many industrial wastewater including leachate from landfill area, wastewater from papermill, dyeing complex, petrochemical processes, etc. are under investigation with electron beam irradiation. For the study of treating dyeing wastewater combined with conventional facilities, an electron beam pilot plant for treating 1,000m 3 /day of wastewater from 80,000m 3 /day of total dyeing wastewater has constructed and operated in Taegu Dyeing Industrial Complex. A commercial plant for re-circulation of wastewater from Papermill Company is also designed for S-paper Co. in Cheongwon City, and after the successful installation, up to 80% of wastewater could be re-used in paper producing process. (author)

  3. Electron beam treatment of industrial wastewater

    International Nuclear Information System (INIS)

    Han, Bumsoo; Kim, JinKyu; Kim, Yuri

    2004-01-01

    For industrial wastewater with low impurity levels such as contaminated ground water, cleaning water and etc., purification only with electron beam is possible, but it should be managed carefully with reducing required irradiation doses as low as possible. Also for industrial wastewater with high impurity levels such as dyeing wastewater, leachate and etc., purification only with electron beam requires high amount of doses and far beyond economies. Electron beam treatment combined with conventional purification methods such as coagulation, biological treatment, etc. is suitable for reduction of non-biodegradable impurities in wastewater and will extend the application area of electron beam. A pilot plant with electron beam for treating 1,000 m 3 /day of wastewater from dyeing industries has constructed and operated continuously since Oct 1998. Electron beam irradiation instead of chemical treatment shows much improvement in removing impurities and increases the efficiency of biological treatment. Actual plant is under consideration based upon the experimental results. (author)

  4. Characteristics and Biodegradability of Wastewater Organic Matter in Municipal Wastewater Treatment Plants Collecting Domestic Wastewater and Industrial Discharge

    OpenAIRE

    Yun-Young Choi; Seung-Ryong Baek; Jae-In Kim; Jeong-Woo Choi; Jin Hur; Tae-U Lee; Cheol-Joon Park; Byung Joon Lee

    2017-01-01

    Municipal wastewater treatment plants (WWTPs) in Korea collect and treat not only domestic wastewater, but also discharge from industrial complexes. However, some industrial discharges contain a large amount of non-biodegradable organic matter, which cannot be treated properly in a conventional biological WWTP. This study aimed to investigate the characteristics and biodegradability of the wastewater organic matter contained in the industrial discharges and to examine the fate of the industri...

  5. NF-RO Membrane Performance for Treating the Effluent of an Organized Industrial Zone Wastewater Treatment Plant: Effect of Different UF Types

    OpenAIRE

    İbrahim Uyanık; Oktay Özkan; İsmail Koyuncu

    2017-01-01

    Reuse of water is necessary in Organized Industrial Zones (OIZ) due to excessive use of groundwater in semi-arid Turkey. Membrane treatment of the OIZ wastewater treatment plant (WWTP) effluents should be explored for new treatment options. In this study, three different UF membranes with variable molecular weight cutoff (MWCO) values (4, 10, and 250 kDa) were used to treat the effluent of an OIZ WWTP at laboratory scale. Six different nanofiltration (NF) and reverse osmosis (RO) membranes we...

  6. Recent Progress in TiO2-Mediated Solar Photocatalysis for Industrial Wastewater Treatment

    OpenAIRE

    Tong Zhang; Xiaoguang Wang; Xiwang Zhang

    2014-01-01

    The current paper reviews the application of TiO2-mediated solar photocatalysis for industrial wastewater treatment, starting with a brief introduction on the background of industrial wastewater and the development of wastewater treatment processes, especially advanced oxidation processes (AOPs). We, then, discuss the application of solar TiO2 photocatalysis in treating different kinds of industrial wastewater, such as paper mill wastewater, textile wastewater, and olive mill wastewater. In t...

  7. How do we treat our wastewater?

    Science.gov (United States)

    Vandas, Stephen; White, Carmelita; Farrar, Frank

    1996-01-01

    Water used in homes, schools, businesses, and industries must be cleaned or treated before it can be used again or returned to the environment. No matter where you live, in an urban or rural setting, the water you use does not just disappear: it is piped to a treatment system. The treatment of wastewater is important to keeping our water clean. This poster depicts what happens to

  8. Biological hydrogen production from industrial wastewaters

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, Guilherme; Pantoja Filho, Jorge Luis Rodrigues; Zaiat, Marcelo [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). School of Engineering. Dept. Hydraulics and Sanitation], Email: peixoto@sc.usp.br

    2010-07-01

    This research evaluates the potential for producing hydrogen in anaerobic reactors using industrial wastewaters (glycerol from bio diesel production, wastewater from the parboilization of rice, and vinasse from ethanol production). In a complementary experiment the soluble products formed during hydrogen production were evaluated for methane generation. The assays were performed in batch reactors with 2 liters volume, and sucrose was used as a control substrate. The acidogenic inoculum was taken from a packed-bed reactor used to produce hydrogen from a sucrose-based synthetic substrate. The methanogenic inoculum was taken from an upflow anaerobic sludge blanket reactor treating poultry slaughterhouse wastewater. Hydrogen was produced from rice parboilization wastewater (24.27 ml H{sub 2} g{sup -1} COD) vinasse (22.75 ml H{sub 2} g{sup -1} COD) and sucrose (25.60 ml H{sub 2} g{sup -1} COD), while glycerol only showed potential for methane generation. (author)

  9. Toxicity identification evaluation of cosmetics industry wastewater.

    Science.gov (United States)

    de Melo, Elisa Dias; Mounteer, Ann H; Leão, Lucas Henrique de Souza; Bahia, Renata Cibele Barros; Campos, Izabella Maria Ferreira

    2013-01-15

    The cosmetics industry has shown steady growth in many developing countries over the past several years, yet little research exists on toxicity of wastewaters it generates. This study describes a toxicity identification evaluation conducted on wastewater from a small Brazilian hair care products manufacturing plant. Physicochemical and ecotoxicological analyses of three wastewater treatment plant inlet and outlet samples collected over a six month period revealed inefficient operation of the treatment system and thus treated wastewater organic matter, suspended solids and surfactants contents consistently exceeded discharge limits. Treated wastewater also presented high acute toxicity to Daphnia similis and chronic toxicity to Ceriodaphnia dubia and Pseudokirchneriella subcapitata. This toxicity was associated with suspended solids, volatile or sublatable and non-polar to moderately polar organic compounds that could be recovered in filtration and aeration residues. Seven surfactants used in the largest quantities in the production process were highly toxic to P. subcapitata and D. similis. These results indicated that surfactants, important production raw materials, are a probable source of toxicity, although other possible sources, such as fragrances, should not be discarded. Improved treatment plant operational control may reduce toxicity and lower impact of wastewater discharge to receiving waters. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Analysis of Wastewater Treatment Efficiency in a Soft Drinks Industry

    Science.gov (United States)

    Boguniewicz-Zabłocka, Joanna; Capodaglio, Andrea G.; Vogel, Daniel

    2017-10-01

    During manufacturing processes, most industrial plants generate wastewater which could become harmful to the environment. Discharge of untreated or improperly treated industrial wastewaters into surface water could, in fact, lead to deterioration of the receiving water body's quality. This paper concerns wastewater treatment solutions used in the soft drink production industry: wastewater treatment plant effectiveness analysis was determined in terms of basic pollution indicators, such as BOD, COD, TSS and variable pH. Initially, the performance of mechanic-biological systems for the treatment of wastewater from a specific beverages production process was studied in different periods, due to wastewater flow fluctuation. The study then showed the positive effects on treatment of wastewater augmentation by methanol, nitrogen and phosphorus salts dosed into it during the treatment process. Results confirm that after implemented modification (methanol, nitrogen and phosphorus additions) pollution removal occurs mostly with higher efficiency.

  11. Analysis of Wastewater Treatment Efficiency in a Soft Drinks Industry

    Directory of Open Access Journals (Sweden)

    Boguniewicz-Zabłocka Joanna

    2017-01-01

    Full Text Available During manufacturing processes, most industrial plants generate wastewater which could become harmful to the environment. Discharge of untreated or improperly treated industrial wastewaters into surface water could, in fact, lead to deterioration of the receiving water body's quality. This paper concerns wastewater treatment solutions used in the soft drink production industry: wastewater treatment plant effectiveness analysis was determined in terms of basic pollution indicators, such as BOD, COD, TSS and variable pH. Initially, the performance of mechanic-biological systems for the treatment of wastewater from a specific beverages production process was studied in different periods, due to wastewater flow fluctuation. The study then showed the positive effects on treatment of wastewater augmentation by methanol, nitrogen and phosphorus salts dosed into it during the treatment process. Results confirm that after implemented modification (methanol, nitrogen and phosphorus additions pollution removal occurs mostly with higher efficiency.

  12. Evaluation of the treatment performance and microbial communities of a combined constructed wetland used to treat industrial park wastewater.

    Science.gov (United States)

    Xu, Ming; Liu, Weijing; Li, Chao; Xiao, Chun; Ding, Lili; Xu, Ke; Geng, Jinju; Ren, Hongqiang

    2016-06-01

    Constructed wetlands are ecosystems that use plants and microorganisms to remediate pollution in soil and water. In this study, two parallel pilot-scale vertical flow wetland and horizontal flow wetland (VF-HF) systems were implemented to investigate the treatment performance and microorganism community structure in the secondary effluent of an industrial park wastewater treatment plant (WWTP) with a loading rate of 100 mm/day near the Yangtze River in Suzhou City, East China. Removal efficiencies of 82.3, 69.8, 77.8, and 32.3 were achieved by the VF-HF systems for ammonium nitrogen (NH4 (+)-N), total nitrogen (TN), total phosphorus (TP), and chemical oxygen demand (COD), respectively. The VF system specialized in COD and NH4 (+)-N removal (73.6 and 79.2 %), whereas the HF system mainly contributed to TN removal (63.5 %). The effluents in all seasons are capable of achieving the "surface water environmental quality standard" (GB3838-2002) grade IV. In the VF system, the 16S gene and nirK gene were significantly correlated with depth, with the 16S gene showing significant correlations with the dissolved oxygen (DO) level (r = 0.954, p < 0.05), which was determined by real-time PCR and high-throughput sequencing. Many types of bacteria capable of biodegradation, including nitrifiers, denitrifiers, and polyaromatic hydrocarbon (PAH) degraders (improvement of the BOD5/COD ratio), were observed, and they contributed to approximately 90 % of the nitrogen removal in the VF-HF system.

  13. Removal Of Heavy Metals From Industrial Wastewaters Using Local ...

    African Journals Online (AJOL)

    Wastewater samples from battery, paint and textile industries were treated with different doses of locally available alum, aluminum sulphate and ferric chloride in order to determine and compare their effectiveness in removing heavy metal contents from the wastewaters. The percentage removal of the metals from the ...

  14. Irrigation of treated wastewater in Braunschweig, Germany

    DEFF Research Database (Denmark)

    Ternes, T.A.; Bonerz, M.; Herrmann, N.

    2007-01-01

    In this study the fate of pharmaceuticals and personal care products which are irrigated on arable land with treated municipal waste-water was investigated. In Braunschweig, Germany, wastewater has been irrigated continuously for more than 45 years. In the winter time only the effluent of the sew......In this study the fate of pharmaceuticals and personal care products which are irrigated on arable land with treated municipal waste-water was investigated. In Braunschweig, Germany, wastewater has been irrigated continuously for more than 45 years. In the winter time only the effluent...

  15. Applications of Natural Coagulants to Treat Wastewater − A Review

    Directory of Open Access Journals (Sweden)

    Kumar Vicky

    2017-01-01

    Full Text Available The natural water falls from the mountain is merging into the oceans. This water is preserved by humans that are consumed for agriculture, industrial, and municipal use. This water become wastewater after different usage, and finally, completes the hydrological cycle. The water becomes wastewater due to population growth, urbanization, industrialization, sewage from household, institutions, hospitals, industries and etc. Wastewater can be destructive for the public because it contains a variety of organic and inorganic substances, biological substances, toxic inorganic compounds and the presence of toxic materials. The coagulant chemicals and its associated products are resourceful but these may change the characteristics of water in terms of physical and chemical characteristics, this make matters worse in the disposal of sludge. An option of natural polymer can be used in water and wastewater in this review. The natural polymers are most efficient that provide several benefits such as; prolific, exempt from physical and chemical changes from the treated water.

  16. Application of electron beam to industrial wastewater treatment

    International Nuclear Information System (INIS)

    Han, B.; Kim, D.K.; Boo, J.Y.; Kim, J.K.; Kim, Y.; Chung, W.; Choi, J.S.; Kang, H.J.; Pikaev, A.K.

    2001-01-01

    Global withdrawals of water to satisfy human demands have grown dramatically in this century. Between 1900 and 1995, water consumption increased by over six times, more than double the rate of population growth. This rapid growth in water demand is due to the increasing reliance on irrigation to achieve food security, the growth of industrial uses, and the increasing use per capita for domestic purposes. Given the seriousness of the situation and future risk of crises, there is an urgent need to develop the water efficient technologies including economical treatment methods of wastewater and polluted water. In the Central Research Institute of Samsung Heavy Industries (SHI), many industrial wastewater including leachate from landfill area, wastewater from papermill, dyeing complex, petrochemical processes, etc. are under investigation with EB irradiation. For the study of treating dyeing wastewater combined with conventional facilities, an EB pilot plant for treating 1,000m 3 /day of wastewater from 60,000m 3 /day of total dyeing wastewater has been constructed and operated in Taegu Dyeing Industrial Complex. A commercial plant for re-circulation of wastewater from Papermill Company is also designed for S-paper Co. in Cheongwon City, and after the successful installation, up to 80% of wastewater could be re-used in paper producing process. (author)

  17. Archaeal Diversity in Biofilm Technologies Applied to Treat Urban and Industrial Wastewater: Recent Advances and Future Prospects

    Directory of Open Access Journals (Sweden)

    Jesús González-López

    2013-09-01

    Full Text Available Biological wastewater treatment (WWT frequently relies on biofilms for the removal of anthropogenic contaminants. The use of inert carrier materials to support biofilm development is often required, although under certain operating conditions microorganisms yield structures called granules, dense aggregates of self-immobilized cells with the characteristics of biofilms maintained in suspension. Molecular techniques have been successfully applied in recent years to identify the prokaryotic communities inhabiting biofilms in WWT plants. Although methanogenic Archaea are widely acknowledged as key players for the degradation of organic matter in anaerobic bioreactors, other biotechnological functions fulfilled by Archaea are less explored, and research on their significance and potential for WWT is largely needed. In addition, the occurrence of biofilms in WWT plants can sometimes be a source of operational problems. This is the case for membrane bioreactors (MBR, an advanced technology that combines conventional biological treatment with membrane filtration, which is strongly limited by biofouling, defined as the undesirable accumulation of microbial biofilms and other materials on membrane surfaces. The prevalence and spatial distribution of archaeal communities in biofilm-based WWT as well as their role in biofouling are reviewed here, in order to illustrate the significance of this prokaryotic cellular lineage in engineered environments devoted to WWT.

  18. Genome Analysis of a Novel Broad Host Range Proteobacteria Phage Isolated from a Bioreactor Treating Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    Marina de Leeuw

    2017-01-01

    Full Text Available Bacteriophages are viruses that infect bacteria, and consequently they have a major impact on the development of a microbial population. In this study, the genome of a novel broad host range bacteriophage, Aquamicrobium phage P14, isolated from a wastewater treatment plant, was analyzed. The Aquamicrobium phage P14 was found to infect members of different Proteobacteria classes (Alphaproteobacteria and Betaproteobacteria. This phage contains a 40,551 bp long genome and 60% of its genes had blastx hits. Furthermore, the bacteriophage was found to share more than 50% of its genes with several podoviruses and has the same gene order as other polyvalent bacteriophages. The results obtained in this study led to the conclusion that indeed general features of the genome of the Aquamicrobium phage P14 are shared with other broad host range bacteriophages, however further analysis of the genome is needed in order to identify the specific mechanisms which enable the bacteriophage to infect both Alphaproteobacteria and Betaproteobacteria.

  19. Characteristics and Biodegradability of Wastewater Organic Matter in Municipal Wastewater Treatment Plants Collecting Domestic Wastewater and Industrial Discharge

    Directory of Open Access Journals (Sweden)

    Yun-Young Choi

    2017-06-01

    Full Text Available Municipal wastewater treatment plants (WWTPs in Korea collect and treat not only domestic wastewater, but also discharge from industrial complexes. However, some industrial discharges contain a large amount of non-biodegradable organic matter, which cannot be treated properly in a conventional biological WWTP. This study aimed to investigate the characteristics and biodegradability of the wastewater organic matter contained in the industrial discharges and to examine the fate of the industrial discharges in a biological WWTP. In contrast to most previous studies targeting a specific group of organic compounds or traditional water quality indices, such as biological oxygen demand (BOD and chemical oxygen demand (COD, this study was purposed to quantify and characterize the biodegradable and nonbiodegradable fractions of the wastewater organic matter. Chemical oxygen demand (COD fractionation tests and fluorescence spectroscopy revealed that the industrial discharge from dyeing or pulp mill factories contained more non-biodegradable soluble organic matter than did the domestic wastewater. Statistical analysis on the WWTPs’ monitoring data indicated that the industrial discharge containing non-biodegradable soluble organic matter was not treated effectively in a biological WWTP, but was escaping from the system. Thus, industrial discharge that contained non-biodegradable soluble organic matter was a major factor in the decrease in biodegradability of the discharge, affecting the ultimate fate of wastewater organic matter in a biological WWTP. Further application of COD fractionation and fluorescence spectroscopy to wastewaters, with various industrial discharges, will help scientists and engineers to better design and operate a biological WWTP, by understanding the fate of wastewater organic matter.

  20. Performance evaluation of a granular activated carbon-sequencing batch biofilm reactor pilot plant system used in treating real wastewater from recycled paper industry.

    Science.gov (United States)

    Muhamad, Mohd Hafizuddin; Sheikh Abdullah, Siti Rozaimah; Mohamad, Abu Bakar; Rahman, Rakmi Abdul; Kadhum, Abdul Amir Hasan

    2012-01-01

    A pilot scale granular activated carbon-sequencing batch biofilm reactor with a capacity of 2.2 m3 was operated for over three months to evaluate its performance treating real recycled paper industry wastewater under different operational conditions. In this study, dissolved air floatation (DAF) and clarifier effluents were used as influent sources of the pilot plant. During the course of the study, the reactor was able to biodegrade the contaminants in the incoming recycled paper mill wastewater in terms of chemical oxygen demand (COD), adsorbable organic halides (AOX; specifically 2,4-dichlorophenol (2,4-DCP)) and ammoniacal nitrogen (NH3-N) removal efficiencies at varying hydraulic retention times (HRTs) of 1-3 days, aeration rates (ARs) of 2.1-3.4 m3/min and influent feed concentration of 40-950 mg COD/l. Percentages of COD, 2,4-DCP and NH3-N removals increased with increasing HRT, resulting in more than 90% COD, 2,4-DCP and NH3-N removals at HRT values above two days. Degradation of COD, 2,4-DCP and NH3-N were seriously affected by variation of ARs, which resulted in significant decrease of COD, 2,4-DCP and NH3-N removals by decreasing ARs from 3.4 m3/min to 2.1 m3/min, varying in the ranges of 24-80%, 6-96% and 5-42%, respectively. In comparison to the clarifier effluent, the treatment performance of DAF effluent, containing high COD concentration, resulted in a higher COD removal of 82%. The use of diluted DAF effluent did not improve significantly the COD removal. Higher NH3-N removal efficiency of almost 100% was observed during operation after maintenance shutdown compared to normal operation, even at the same HRT of one day due to the higher dissolved oxygen concentrations (1-7 mg/l), while no significant difference in COD removal efficiency was observed.

  1. Technical note Biological treatment of industrial wastewater ...

    African Journals Online (AJOL)

    The biological treatment of wastewater from an aminoplastic resin-producing industry was studied in a pre-denitrification system. This study reports results on the removal of organic matter and nitrogen compounds from wastewater which contained high levels of formaldehyde and formic acid. The formaldehyde ...

  2. Municipal Treated Wastewater Irrigation: Microbiological Risk Evaluation

    Directory of Open Access Journals (Sweden)

    Antonio Lonigro

    2008-06-01

    Full Text Available Municipal wastewater for irrigation, though treated, can contain substances and pathogens toxic for humans and animals. Pathogens, although not harmful from an agronomical aspect, undoubtedly represent a major concern with regards to sanitary and hygienic profile. In fact, vegetable crops irrigated with treated wastewater exalt the risk of infection since these products can also be eaten raw, as well as transformed or cooked. Practically, the evaluation of the microbiological risk is important to verify if the microbial limits imposed by law for treated municipal wastewater for irrigation, are valid, thus justifying the treatments costs, or if they are too low and, therefore, they don’ t justify them. Different probabilistic models have been studied to assess the microbiological risk; among these, the Beta-Poisson model resulted the most reliable. Thus, the Dipartimento di Scienze delle Produzioni Vegetali of the University of Bari, which has been carrying out researches on irrigation with municipal filtered wastewater for several years, considered interesting to verify if the microbial limits imposed by the italian law n.185/03 are too severe, estimating the biological risk by the probabilistic Beta-Poisson model. Results of field trials on vegetable crops irrigated by municipal filtered wastewater, processed by the Beta-Poisson model, show that the probability to get infection and/or illness is extremely low, and that the actual italian microbial limits are excessively restrictive.

  3. Treated Wastewater Reuse on Potato (Solanum Tuberosum)

    DEFF Research Database (Denmark)

    Battilani, A; Plauborg, Finn; Andersen, Mathias Neumann

    2014-01-01

    increased by 635 and 765 euro ha-1y-1 with FTS and MBR, respectively. Tubers were not contaminated by E. coli found in treated wastewater used for irrigation. The frequency of heavy metal and nitrate detection in tubers were comparable among water sources, as well as for the average contents. Only for boron...

  4. Tertiary activated carbon treatment of paper and board industry wastewater

    NARCIS (Netherlands)

    Temmink, B.G.; Grolle, K.C.F.

    2005-01-01

    The feasibility of activated carbon post-treatment of (biologically treated) wastewater from the paper and board industry was investigated, the goal being to remove refractory organic pollutants and produce water that can be re-used in the production process. Because closing water-circuits in the

  5. Recent Progress in TiO2-Mediated Solar Photocatalysis for Industrial Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Tong Zhang

    2014-01-01

    Full Text Available The current paper reviews the application of TiO2-mediated solar photocatalysis for industrial wastewater treatment, starting with a brief introduction on the background of industrial wastewater and the development of wastewater treatment processes, especially advanced oxidation processes (AOPs. We, then, discuss the application of solar TiO2 photocatalysis in treating different kinds of industrial wastewater, such as paper mill wastewater, textile wastewater, and olive mill wastewater. In the end, we compare solar TiO2 photocatalysis with other AOPs in terms of effectiveness, energy, and chemical consumption. Personal perspectives are also given, which may provide new insights to the future development of TiO2 photocatalysis for industrial wastewater.

  6. Case studies on the physical-chemical parameters' variation during three different purification approaches destined to treat wastewaters from food industry.

    Science.gov (United States)

    Ghimpusan, Marieta; Nechifor, Gheorghe; Nechifor, Aurelia-Cristina; Dima, Stefan-Ovidiu; Passeri, Piero

    2017-12-01

    The paper presents a set of three interconnected case studies on the depuration of food processing wastewaters by using aeration & ozonation and two types of hollow-fiber membrane bioreactor (MBR) approaches. A secondary and more extensive objective derived from the first one is to draw a clearer, broader frame on the variation of physical-chemical parameters during the purification of wastewaters from food industry through different operating modes with the aim of improving the management of water purification process. Chemical oxygen demand (COD), pH, mixed liquor suspended solids (MLSS), total nitrogen, specific nitrogen (NH 4 + , NO 2 - , NO 3 - ) total phosphorous, and total surfactants were the measured parameters, and their influence was discussed in order to establish the best operating mode to achieve the purification performances. The integrated air-ozone aeration process applied in the second operating mode lead to a COD decrease by up to 90%, compared to only 75% obtained in a conventional biological activated sludge process. The combined purification process of MBR and ozonation produced an additional COD decrease of 10-15%, and made the Total Surfactants values to comply to the specific legislation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Cultivation of microalgae in industrial wastewaters

    DEFF Research Database (Denmark)

    van Wagenen, Jonathan Myerson

    Microalgae production for the purpose of clearing wastewater has been researched for at least half a century. Such systems have a dual benefit: first, they prevent nutrients from entering water bodies and causing eutrophication; second, they transform sunlight and carbon dioxide into a biomass...... cultivation. When algae are grown within a wastewater treatment plant, the use of the chemical energy stored in the organic carbon dissolved in the wastewater could also be a useful option. Conventional aerobic sewage treatment expends much energy in breaking down the biomass to CO2. However, various...... of the nutritionally important α-Linoleic fatty acid increased when light intensity and dilution rate were higher. Valuable pigments lutein, carotene and other carotenoids were higher in low-light conditions. The results from this thesis demonstrate that industrial wastewater can be a suitable replacement for algae...

  8. Possible Use of Treated Wastewater as Irrigation Water at Urban Green Area

    Directory of Open Access Journals (Sweden)

    Elif Bozdoğan

    2014-08-01

    Full Text Available Ever increasing demands for fresh water resources have brought the reuse of treated wastewater into agendas. Wastewater has year-long potential to be used as an irrigation water source. Therefore, treated wastewater is used as irrigation water over agricultural lands and urban landscapes, as process water in industrial applications, as back-up water in environmental applications in water resources and wetlands of dry regions. The present study was conducted to investigate the possible use of domestic wastewater treated through pilot-scale constructed wetland of Adana-Karaisalı with dominant Mediterranean climate in irrigation of marigold (Tagetes erecta, commonly used over urban landscapes. Experiments were carried out between the dates May-November 2008 for 7 months with fresh water and treated wastewater. Plant growth parameters (plant height, plant diameter, number of branches and flowering parameters (number of flowers, flower diameter, flower pedicle thickness were monitored in monthly basis. Results revealed positive impacts of treated wastewater irrigations on plant growth during the initial 5 months between May-September but negative impacts in October and November. Similarly, treated wastewater irrigations had positive impacts on flowering parameters during the initial 3 months but had negative impacts during the subsequent 4 months. Such a case indicated shortened visual efficiencies of marigold. Therefore, treated wastewater can be used as an alternative water resource in irrigation of annual flowers, but better results can be attained by mixing treated wastewater with fresh water at certain ratios.

  9. Construction of Industrial Electron Beam Plant for Wastewater Treatment

    International Nuclear Information System (INIS)

    Han, B.; Kim, J.; Kim, Y.; Kim, S.; Lee, M.; Choi, J.; Ahn, S.; Makarov, I.E.; Ponomarev, A.V.

    2004-01-01

    A pilot plant for treating 1,000 m3/day of dyeing wastewater with e-beam has been constructed and operated since 1998 in Daegu, Korea together with the biological treatment facility. The wastewater from various stages of the existing purification process has been treated with electron beam in this plant, and it gave rise to elaborate the optimal technology of the electron beam treatment of wastewater with increased reliability at instant changes in the composition of wastewater. Installation of the e-beam pilot plant resulted in decolorizing and destructive oxidation of organic impurities in wastewater, appreciable to reduction of chemical reagent consumption, in reduction of the treatment time, and in increase in flow rate limit of existing facilities by 30-40%. Industrial plant for treating 10,000 m3/day, based upon the pilot experimental result, is under construction and will be finished by 2005. This project is supported by the International Atomic Energy Agency (IAEA) and Korean Government

  10. Thermophilic biological nitrogen removal in industrial wastewater treatment.

    Science.gov (United States)

    Lopez-Vazquez, C M; Kubare, M; Saroj, D P; Chikamba, C; Schwarz, J; Daims, H; Brdjanovic, D

    2014-01-01

    Nitrification is an integral part of biological nitrogen removal processes and usually the limiting step in wastewater treatment systems. Since nitrification is often considered not feasible at temperatures higher than 40 °C, warm industrial effluents (with operating temperatures higher than 40 °C) need to be cooled down prior to biological treatment, which increases the energy and operating costs of the plants for cooling purposes. This study describes the occurrence of thermophilic biological nitrogen removal activity (nitritation, nitratation, and denitrification) at a temperature as high as 50 °C in an activated sludge wastewater treatment plant treating wastewater from an oil refinery. Using a modified two-step nitrification-two-step denitrification mathematical model extended with the incorporation of double Arrhenius equations, the nitrification (nitrititation and nitratation) and denitrification activities were described including the cease in biomass activity at 55 °C. Fluorescence in situ hybridization (FISH) analyses revealed that Nitrosomonas halotolerant and obligatehalophilic and Nitrosomonas oligotropha (known ammonia-oxidizing organisms) and Nitrospira sublineage II (nitrite-oxidizing organism (NOB)) were observed using the FISH probes applied in this study. In particular, this is the first time that Nitrospira sublineage II, a moderatedly thermophilic NOB, is observed in an engineered full-scale (industrial) wastewater treatment system at temperatures as high as 50 °C. These observations suggest that thermophilic biological nitrogen removal can be attained in wastewater treatment systems, which may further contribute to the optimization of the biological nitrogen removal processes in wastewater treatment systems that treat warm wastewater streams.

  11. In-plant testing of membranes to treat electroplating wastewater

    Science.gov (United States)

    Shah, D. B.; Talu, Orhan

    1995-01-01

    This is the final report submitted for the work performed under the NASA Cooperative Agreement NCC3-301 for the project entitled 'In-Plant Testing of Membranes To Treat Electroplating Waste water'. The main objective of the research project was to determine if the crosslinked polyacrylic acid salt films developed by NASA scientists could be used for heavy metal removal from the wastewater generated by the metals-finishing or electroplating industry. A variety of tasks identified in the original proposal were completed. These included: (1) analysis of our industrial partner Aetna Plating's zinc electroplating process and its wastewater treatment needs for zinc removal; (2) design and construction of a laboratory-scale unit to continuously supply and remove the ion exchange films from the zinc wastewater; (3) performance of a series of runs on such a unit to determine its operating characteristics; and (4) design of a prototype unit for use at the industrial site. In addition, there were a number of tasks that had not been identified in the original proposal but were later judged to be necessary for the successful completion of the project. These were: (1) batch equilibrium and kinetic experiments with analysis of the experimental results to accurately determine the equilibrium and kinetic parameters for the ion exchange films; (2 ) simulation studies for proper design of the prototype unit; and (3) preliminary runs to exchange the films from H form to Calcium form.

  12. Radiation Treatment for Recycling of Industrial Wastewater for Industrial Usage - Biological and Irradiation Treatment of Mix Industrial Wastewater in Flood Mitigation Pond at Prai Industrial Zones

    International Nuclear Information System (INIS)

    Bakar, Khomsaton Abu; Sharif, Jamaliah; Selambakkanu, Sarala; Ming, Ting Teo; Isnin, Natsha; Osman, Hasnul Nizam; Azmi, Khasmidatul Akma M.K; Dahlan, Khairul Zaman Hj Mohd; Yahya, Nasehir khan Em

    2012-01-01

    In this research, activated sludge system and E-Beam was used to treat mixed industrial waste water from mitigation pond A. The objectives are to study the effect of hydraulic retention time (HRT) in activated sludge and effect of absorbed dose, current and energy to the characteristic of mix industrial wastewater and Di(2-ethylhexyl) phthalate(DEHP) added in the wastewater. DEPH is a type of plasticizer and quantified by GC-MS. Microbe identification in activated sludge was also carried out in this study. At 48hrs HRT, percentage reduction for COD, color, suspended solid were 62.3%, 36.7% and 67.1% respectively. While at 24hrs HRT, COD, color and suspended solid were reduce by 26.0%, 14.9% and 61.3% respectively. Microbial analysis showed six bacteria present in the activated sludge based on 16SrRNA gene sequences. Mixed industrial wastewater was irradiated using electron beam at 1Mev, 5mA and 10mA in a batch system with 3, 6, 8,10 and 12kGy doses. COD, color and suspended solid reduced with the increasing of absorbed dose. Mixed industrial wastewater added with DEPH in the second batch was irradiated with dose up to 300kGy. Concentration of DEHP also reduced with increasing of dose and more effectively decreased in acidic and aerated condition. (author)

  13. Agricultural use of treated municipal wastewaters preserving environmental sustainability

    OpenAIRE

    Pietro Rubino; Maurizia Catalano; Antonio Lonigro

    2007-01-01

    In this paper the utility of the treated municipal wastewaters in agriculture, analyzing the chemical, physical and microbiological characteristics and their pollution indicators evaluation are being illustrated. Some methods employed for treating wastewaters are examined, as well as instructions and rules actually in force in different countries of the world, for evaluating the legislative hygienic and sanitary and agronomic problems connected with the treated wastewaters use, are being coll...

  14. Removal of Alkylphenols from Industrial and Municipal Wastewater

    Directory of Open Access Journals (Sweden)

    J. Derco

    2017-07-01

    Full Text Available The results of the study of removal of nonylphenol, octylphenol and their ethoxylates from real industrial and municipal wastewater are presented. Industrial wastewater was pre-treated by coagulation with FeCl3 and adsorption on zeolite, before discharging into municipal sewer system. Their removal efficiencies in primary sedimentation tank of municipal WWTP were very low. From the practical point of view, the highest and the most significant removal efficiencies within the whole WWTP were observed for nonylphenol and nonylphenol ethoxylates. Dominancy of abiotic mechanisms of alkylphenols removal follows from adsorption measurements. Activated sludge cultivated in lab-scale extended aeration tank accounted for relatively high adsorption affinity to these substances. Activated sludge sampled from municipal wastewater treatment plant (MWWTP receiving industrial wastewater containing alkylphenols accounted for very low adsorption affinity to these pollutants. Significantly higher removal efficiency of octylphenol ethoxylates was observed with the O3/granular active carbon (GAC process compared to the ozonation process alone. Lower toxicity impact of intermediates and products of ozonation treatment on Vibrio fischeri was measured in comparison to the O3/GAC process. Actually, the municipal WWTP effluent discharge concentration values complies with EQS values, including nonylphenols.

  15. Wastewater treatment and reclamation: a review of pulp and paper industry practices and opportunities

    OpenAIRE

    Hubbe, Martin A.; Metts, Jeremy R.; Hermosilla, Daphne; Angeles Blanco, M.; Yerushalmi, Laleh; Haghighat, Fariborz; Lindholm-Lehto, Petra; Khodaparast, Zahra; Kamali, Mohammadreza; Elliott, Allan

    2016-01-01

    The pulp and paper (P&P) industry worldwide has achieved substantial progress in treating both process water and wastewater, thus limiting the discharge of pollutants to receiving waters. This review covers a variety of wastewater treatment methods, which provide P&P companies with cost-effective ways to limit the release of biological or chemical oxygen demand, toxicity, solids, color, and other indicators of pollutant load. Conventional wastewater treatment systems, often comprising primary...

  16. Comparison of Fenton process and adsorption method for treatment of industrial container and drum cleaning industry wastewater.

    Science.gov (United States)

    Güneş, Elçin; Çifçi, Deniz İzlen; Çelik, Suna Özden

    2018-04-01

    The present study aims to explore the characterization of industrial container and drum cleaning (ICDC) industry wastewater and treatment alternatives of this wastewater using Fenton and adsorption processes. Wastewater derived from ICDC industry is usually treated by chemical coagulation and biological treatment in Turkey and then discharged in a centralized wastewater treatment facility. It is required that the wastewater COD is below 1500 mg/L to treat in a centralized wastewater treatment facility. The wastewater samples were characterized for parameters of pH, conductivity, COD, BOD 5 , TSS, NH 3 -N, TN, TOC, TP, Cd, Cr, Cu, Fe, Ni, Pb, Zn, and Hg. Initial COD values were in the range of 11,300-14,200 mg/L. The optimum conditions for Fenton treatment were 35-40 g/L for H 2 O 2 , 2-5 g/L for Fe 2+ , and 13-36 for H 2 O 2 /Fe 2+ molar ratio. The optimum conditions of PAC doses and contact times in adsorption studies were 20-30 g/L and 5-12 h, respectively. Removal efficiencies of characterized parameters for the three samples were compared for both Fenton and adsorption processes under optimum conditions. The results suggest that these wastewaters are suitable for discharge to a centralized wastewater treatment plant.

  17. Emerging energy-efficient technologies for the Californian wastewater industry

    NARCIS (Netherlands)

    Slaa, Jan Willem

    2011-01-01

    SUMMARY Wastewater treatment is of vital importance for protecting human health and minimizing the environmental impact of polluted water. Since the beginning of the 20th century public facilities have been installed globally which treat wastewater at a

  18. Biodegradability of tannin-containing wastewater from leather industry.

    Science.gov (United States)

    He, Qiang; Yao, Kai; Sun, Danhong; Shi, Bi

    2007-08-01

    Tannins occur commonly in the wastewaters from forestry, plant medicine, paper and leather industries. The treatment of this kind of wastewaters, including settling and biodegradation, is usually difficult because tannins are highly soluble in water and would inhibit the growth of microorganisms in activated sludge. The objective of this study is to investigate biodegradability of tannin-containing wastewaters, so as to characterize the pollution properties of such wastewaters and provide a reference for their biological treatment in wastewater treatment plants. The research was typified by using the wastewater collected from vegetable tanning process in leather industry. A model was developed to describe the activated sludge process, and the biodegradation kinetics of vegetable tanning wastewater (VET wastewater) was studied. It was found that the biodegradability of tannin-containing wastewater varies heavily with the content of tannins in wastewater. The biodegradation of VET wastewater with tannin content around 4,900 mg/l occurred inefficiently due to the inhibition of tannins to the activated sludge process, and only 34.7% of biodegradation extent was reached in 14 days of incubation. The optimal biodegradability of VET wastewater was observed when its tannin content was diluted to 490 mg/l, where the COD and tannin removals reached 51.3% and 45.1% respectively in 6 days. Hence, it is suggested that a proper control of tannin content is necessary to achieve an effective biodegradation of tannin-containing wastewaters in wastewater treatment plants.

  19. Discussion on Wastewater Treatment Process of Coal Chemical Industry

    Science.gov (United States)

    Zhao, Dongyan; Lun, Weijie; Wei, Junjie

    2017-12-01

    Coal chemical wastewater has such characteristics as high concentration of oil, ammonia nitrogen and COD. In this paper, treatment process of coal chemical industry is described mainly, such as pretreatment process, biochemical treatment process and polishing process. Through the recovery of phenol and ammonia and the treatment of wastewater from abroad, the new technology of wastewater treatment in coal chemical industry was expounded. Finally, The development of coal chemical wastewater treatment technology is prospected, and the pretreatment technology is emphasized. According to the diversification and utilization of water, zero discharge of coal chemical wastewater will be fulfilled.

  20. Pollution control of industrial wastewater from soap and oil industries: a case study.

    Science.gov (United States)

    Abdel-Gawad, S; Abdel-Shafy, M

    2002-01-01

    Industrial wastewater from soap and oil industries represents a heavy pollution source on their receiving water body. This paper studies a case of pollution control at Tanta Soap and Oil Company, Banha Factory, Egypt. The factory production includes soap, edible oil, and animal fodder. About 4,347 m3/day of industrial wastewater effluent was discharged via gravity sewers to the public sewerage system. Most of the effluent was cooling water because the cooling process in the factory was open circle. In spite of the huge quantity of cooling water being disposed of, disposal of wastewater was violating pertinent legislation. Three procedures were used for controlling the pollution at the Banha Factory. Firstly, all open circuit cooling systems were converted to closed circuit thus reducing the quantity of the discharged wastewater down to 767 m3/day. Secondly, the heavily polluted oil and grease (O&G) wastewater from the refinery unit is treated via two gravity oil separator (GOS) units, dissolved air floatation (DAF), and biological units in order to reduce the high levels of O&G, BOD, COD, and SS to the allowable limits. Thirdly, the heavily polluted waste effluent from the 'red water' saponification unit is treated separately by acidification to convert the emulsified fatty acid to free form in order to be separated through an oil separation unit. The effluent is then passed to liming stage to neutralize excess acidity and precipitate some of the dissolved matters. The mixture is finally clarified and the pH is adjusted to the allowable limits. The effluent wastewater from the three processes is collected and mixed in a final equalization tank for discharging effluent to the public sewerage system. The characteristics of the effluent water are very good with respect to the allowable Egyptian limits for discharging effluent to the public sewerage system.

  1. Sustainable agro-food industrial wastewater treatment using high rate anaerobic process

    OpenAIRE

    Rajagopal, Rajinikanth; Saady, Noori M. Cata; Torrijos, Michel; Thanikal, Joseph V.; Hung, Yung-Tse

    2013-01-01

    This review article compiles the various advances made since 2008 in sustainable high-rate anaerobic technologies with emphasis on their performance enhancement when treating agro-food industrial wastewater. The review explores the generation and characteristics of different agro-food industrial wastewaters; the need for and the performance of high rate anaerobic reactors, such as an upflow anaerobic fixed bed reactor, an upflow anaerobic sludge blanket (UASB) reactor, hybrid systems etc.; op...

  2. Environmental footprint of constructed wetlands treating wastewater.

    Science.gov (United States)

    Gkika, Dimitra; Gikas, Georgios D; Tsihrintzis, Vassilios A

    2015-01-01

    The aim of the study is to determine environmentally friendlier construction materials for constructed wetland facilities treating wastewater. This is done by computing the environmental footprint of the facility based on the methodology of life cycle assessment (LCA). This methodology reveals the dominant aggravating processes during the construction of a constructed wetland (CW) and can help to create alternative environmentally friendlier solutions. This methodology was applied for the determination of the overall environmental profile of a hybrid CW facility. The LCA was applied first to the facility as originally designed, where reinforced concrete was used in some components. Then, alternative construction materials to reinforced concrete were used, such as earth covered with high density polyethylene (HDPE) or clay, and LCA was applied again. Earth structures were found to have reduced environmental impact compared to concrete ones, and clay was found environmentally friendlier compared to HDPE. Furthermore, estimation of the construction costs of the three scenarios indicate that the last scenario is also the least expensive.

  3. Biodiesel production from algae grown on food industry wastewater.

    Science.gov (United States)

    Mureed, Khadija; Kanwal, Shamsa; Hussain, Azhar; Noureen, Shamaila; Hussain, Sabir; Ahmad, Shakeel; Ahmad, Maqshoof; Waqas, Rashid

    2018-04-10

    Algae have an ample potential to produce biodiesel from spent wash of food industry. In addition, it is cheaper and presents an environment friendly way to handle food industry wastewater. This study was conducted to optimize the growth of microalgal strains and to assess biodiesel production potential of algae using untreated food industry wastewater as a source of nutrients. The food industry wastewater was collected and analyzed for its physicochemical characteristics. Different dilutions (10, 20, 40, 80, and 100%) of this wastewater were made with distilled water, and growth of two microalgal strains (Cladophora sp. and Spyrogyra sp.) was recorded. Each type of wastewater was inoculated with microalgae, and biomass was harvested after 7 days. The growth of both strains was also evaluated at varying temperatures, pH and light periods to optimize the algal growth for enhanced biodiesel production. After optimization, biodiesel production by Spyrogyra sp. was recorded in real food industry wastewater. The algal biomass increased with increasing level of food industry wastewater and was at maximum with 100% wastewater. Moreover, statistically similar results were found with algal growth on 100% wastewater and also on Bristol's media. The Cladophora sp. produced higher biomass than Spyrogyra sp. while growing on food industry wastewater. The optimal growth of both microalgal strains was observed at temperature 30 °C, pH: 8, light 24 h. Cladophora sp. was further evaluated for biodiesel production while growing on 100% wastewater and found that this strain produced high level of oil and biodiesel. Algae have an ample potential to produce biodiesel from spent wash of food industry. In addition, it is cheaper and presents an environment friendly way to handle food industry wastewater.

  4. Acrylic acid removal from synthetic wastewater and industrial wastewater using Ralstonia solanacearum and Acidovorax avenae isolated from a wastewater treatment system manufactured with polyacrylonitrile fiber.

    Science.gov (United States)

    Wang, C C; Lee, C M; Wu, A S

    2009-01-01

    Ralstonia solanacearum and Acidovorax avenae were isolated from a wastewater treatment system manufactured with polyacrylonitrile fiber. The investigation goal is to elucidate the effectiveness of Ralstonia solanacearum and Acidovorax avenae in treating acrylic acid from synthetic wastewater and industrial wastewater. The results reveal that Ralstonia solanacearum and Acidovorax avenae could utilize acrylic acid from synthetic wastewater for growth, when the initial acrylic acid concentration was below 1,009.1 mg/l and 1,383.4 mg/l, respectively. When the acrylic acid concentration was below 606.8 mg/l, the acrylic acid removal ability reached 96.7% and 100%, respectively. Both strains could tolerate acrylamide toxicity, but only Ralstonia solanacearum could tolerate acrylonitrile toxicity. Ralstonia solanacearum and Acidovorax avenae could utilize acrylic acid from industrial wastewater for growth, when the initial acrylic acid concentration was below 1,741.1 mg/l and 1,431.2 mg/l, respectively. When the acrylic acid concentration was below 690.8 mg/l, the acrylic acid removal efficiency reached 83.5% and 62.2%, respectively. Whether the acrylic acid existed in synthetic wastewater or in industrial wastewater, the removal efficiency of acrylic acid by Ralstonia solanacearum exceeded that by Acidovorax avena.

  5. Qualitative monitoring of a treated wastewater reuse extensive ...

    African Journals Online (AJOL)

    2006-01-01

    Jan 1, 2006 ... During a five-month summer period, samples of tertiary treated wastewater flowing in an extensive distribution system com- posed of storage tanks and pipes, were collected at two-week intervals from 21 different sampling points, including the exit from the wastewater treatment plant (WWTP). The WWTP ...

  6. Effects of ten years treated wastewater drip irrigation on soil ...

    African Journals Online (AJOL)

    SWEET

    soil contamination and the cumulative impact of wastewater, we compared two plots, all under orange- grove that had been drip irrigated for 10 years. .... evaluated human risk of the organic contaminants in reclaimed wastewater used for ... of our study was to evaluate the effects of treated waste- water irrigation, of 10 years' ...

  7. Effects of ten years treated wastewater drip irrigation on soil ...

    African Journals Online (AJOL)

    No negative effects of treated wastewater drip irrigation treatment were observed on the measured soil parameters (pH, organic matter and cation exchange capacity). A slight increase in the concentration of soil enteric bacteria and soil fungal densities was recorded in the wastewater plot reaching a maximum value in the ...

  8. Incentives for Wastewater Management in Industrial Estates in Vietnam

    OpenAIRE

    Le Quang Thong; Nguyen Anh Ngoc

    2004-01-01

    This study provides information on the level and effectiveness of wastewater pollution control in industrial estates in four provinces of Vietnam. It finds low levels of wastewater treatment in many industrial estates in the areas surveyed and identifies significant negative effects on many rivers. It investigates why many estates and the factories that operate inside them have not invested in wastewater treatment plants. It also looks at why many companies (even those connected to treatments...

  9. DETERMINATION OF THE QUALITY OF INDUSTRIAL LAUNDRY RAW WASTEWATER

    OpenAIRE

    Natalia Dąbkowska

    2017-01-01

    Industrial laundries are one of the largest consumers of water, which is associated with significant generation of laundry wastewater. Water is one of the most important technological factors in the laundry industry. The amount of laundry wastewater generated is the result of the quantity of textile laundered and is roughly equal to the amount of technological water used to reduce the losses caused by evaporation. The quality of raw laundry wastewater depends on the quantity of impurities rem...

  10. Effect of industrial wastewater ontotal protein and the peroxidase ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... The aim of this study is to investigate the effects of industrial wastewaters on protein and the peroxidase activity in Lycopersicon esculentum Mill., Capsicum annuum L., Phaseolus vulgaris L. and. Vicia faba L. Industrial wastewaters were taken from Dardanel Fisheries Company, Tekel alcoholic.

  11. Effect of industrial wastewater ontotal protein and the peroxidase ...

    African Journals Online (AJOL)

    The aim of this study is to investigate the effects of industrial wastewaters on protein and the peroxidase activity in Lycopersicon esculentum Mill., Capsicum annuum L., Phaseolus vulgaris L. and Vicia faba L. Industrial wastewaters were taken from Dardanel Fisheries Company, Tekel alcoholic drinks companies' ...

  12. Removal of arsenic and COD from industrial wastewaters by electrocoagulation

    Directory of Open Access Journals (Sweden)

    H. POIROT

    2011-08-01

    Full Text Available The paper deals with the treatment of arsenic-containing industrial wastewaters by electrocoagulation. The waste issued from a paper mill industry downstream of the biological treatment by activated sludge was enriched with arsenic salts for the purpose of investigation of the treatment of mixed pollution. First, the treatment of single polluted waters, i.e. containing either the regular organic charge from the industrial waste or arsenic salts only, was studied. In the case of arsenic-containing waters, a broad selection of experimental data available in the literature was compiled and interpreted using an adsorption model developed previously. The same technique was used in the case of industrial waste. Arsenic-enriched paper mill wastewaters with various amounts of As salts were then treated by electrocoagulation with Fe electrodes. The set of data obtained were interpreted by a model developed on the basis of the separate models. The agreement between predicted and experimental variations of the As concentrations ranging from 0.3 µg/L to 730 µg/L showed that both the organic matter and As salt can be removed from the liquid independently from each other.

  13. A study on the treatment of industrial wastewater containing heavy metals

    International Nuclear Information System (INIS)

    Yoon, Myoung Hwan; Jang, In Soon; Park, Jang Jin; Choi, Chang Shik; Lee, Yoon Hwan; Shin, Jin Myoung

    1993-06-01

    It is essential to treat heavy metals contained in industrial wastewater safely and economically for the protection of the environment. An effective method of separating heavy metals using acornic acid for the first time in the world must be utilized for wastewater treatment. One of the merits of this method lies in its cheap treatment cost. Furthermore, the secondary contamination, which occurs often when chemical purifiers are used, could be minimized. Another advantage of utilizing the acornic acid is that various kinds of heavy metals contained in industrial wastewater can be purified at once. The final purpose of this project is to commercialize the method by 1994. (Auther)

  14. Agricultural use of treated municipal wastewaters preserving environmental sustainability

    Directory of Open Access Journals (Sweden)

    Pietro Rubino

    2007-07-01

    Full Text Available In this paper the utility of the treated municipal wastewaters in agriculture, analyzing the chemical, physical and microbiological characteristics and their pollution indicators evaluation are being illustrated. Some methods employed for treating wastewaters are examined, as well as instructions and rules actually in force in different countries of the world, for evaluating the legislative hygienic and sanitary and agronomic problems connected with the treated wastewaters use, are being collected and compared. Successively, in order to provide useful indications for the use of treated municipal wastewaters, results of long-term field researches, carried out in Puglia, regarding two types of waters (treated municipal wastewater and conventional water and two irrigation methods (drip and capillary sub-irrigation on vegetable crops grown in succession, are being reported. For each crop cycle, chemical physical and microbiological analyses have been performed on irrigation water, soil and crop samples. The results evidenced that although irrigating with waters having high colimetric values, higher than those indicated by law and with two different irrigation methods, never soil and marketable yield pollutions have been observed. Moreover, the probability to take infection and/or disease for ingestion of fruits coming from crops irrigated with treated wastewaters, calculated by Beta-Poisson method, resulted negligible and equal to 1 person for 100 millions of exposed people. Concentrations of heavy metals in soil and crops were lesser than those admissible by law. The free chlorine, coming from disinfection, found in the wastewaters used for watering, in some cases caused toxicity effects, which determined significant yield decreases. Therefore, municipal wastewaters, if well treated, can be used for irrigation representing a valid alternative to the conventional ones.

  15. [Source identification of toxic wastewaters in a petrochemical industrial park].

    Science.gov (United States)

    Yang, Qian; Yu, Yin; Zhou, Yue-Xi; Chen, Xue-Min; Fu, Xiao-Yong; Wang, Miao

    2014-12-01

    Petrochemical wastewaters have toxic impacts on the microorganisms in biotreatment processes, which are prone to cause deterioration of effluent quality of the wastewater treatment plants. In this study, the inhibition effects of activated sludge's oxygen consumption were tested to evaluate the toxicity of production wastewaters in a petrochemical industrial park. The evaluation covered the wastewaters from not only different production units in the park, but also different production nodes in each unit. No direct correlation was observed between the toxicity effects and the organic contents, suggesting that the toxic properties of the effluents could not be predicted by the organic contents. In view of the variation of activated sludge sensitivity among different tests, the toxicity data were standardized according to the concentration-effect relationships of the standard toxic substance 3, 5-dichlorophenol on each day, in order to improve the comparability among the toxicity data. Furthermore, the Quality Emission Load (QEL) of corresponding standard toxic substance was calculated by multiplying the corresponding 3, 5-dichlorophenol concentration and the wastewater flow quantity, to indicate the toxicity emission contribution of each wastewater to the wastewater treatment plant. According to the rank list of the toxicity contribution of wastewater from different units and nodes, the sources of toxic wastewater in the petrochemical industrial park were clearly identified. This study provides effective guidance for source control of wastewater toxicity in the large industrial park.

  16. Influence of wastewater characteristics on methane potential in food-processing industry wastewaters

    DEFF Research Database (Denmark)

    Maya Altamira, Larisa; Baun, Anders; Angelidaki, Irini

    2008-01-01

    In this study, we identified the influence of wastewater characteristics on the theoretical and practical methane potential using different food industrial wastewaters as substrates. Ten composite wastewater samples from five industries were investigated. The ultimate practical methane yields (Bo......) were compared to the theoretical methane yields (Bo,th) in order to evaluate the biodegradability of the tested wastewaters and the influence of their physico-chemical characteristics. The analytical method applied to quantify the wastewaters’ organic content proved to influence the estimation...... of their theoretical yields. The substrate:inoculum ratio as well as the dilution factor of the wastewaters influenced the ultimate practical methane yields differently in each of the wastewaters assessed. Substrate chemical oxygen demand (COD) concentrations did not present any influence on ultimate practical methane...

  17. The application of ionising radiation in industrial wastewater treatment technology

    International Nuclear Information System (INIS)

    Kos, L.; Perkowski, J.; Ledakowicz, S.

    2003-01-01

    An attempt was made to apply radiation techniques in the treatment of industrial wastewater from a dairy, brewery and sugar factory. For degradation of pollutants present in the wastewater, the following methods were used: irradiation, irradiation combined with aeration, ozonation, and combined irradiation and ozonation. For all three types of wastewater, the best method among these listed above appeared to be the method of irradiation combined with ozonation. Most degradable was the wastewater produced in sugar factories, and the least biodegradable appeared to be dairy wastewater. Depending on the dose of ozone and radiation, a maximum 60% reduction of COD was obtained. No effect of the wastewater aeration on its degradation by radiation was found. Changes in the content of mineral compounds were observed in none of the cases. The process of biological treatment of wastewater was carried out in a low-loaded, wetted bed. Pretreatment of the wastewater had no significant effect on the improvement of the biological step operation. Some effect was observed only in the case of the wastewater coming from a sugar factory. For medium concentrated wastewater from food industry, it is not economically justified to apply the pretreatment with the use of ionising radiation. (orig.)

  18. Dataset of producing and curing concrete using domestic treated wastewater.

    Science.gov (United States)

    Asadollahfardi, Gholamreza; Delnavaz, Mohammad; Rashnoiee, Vahid; Fazeli, Alireza; Gonabadi, Navid

    2016-03-01

    We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m(3) of cement before chlorination and then cured concrete samples made with drinking water and treated wastewater. Second, concrete samples made with 350 kg/m(3) of cement with a Superplasticizer admixture made with drinking water and treated wastewater and then cured with treated wastewater. The compressive strength of all the concrete samples made with treated wastewater had a high coefficient of determination with the control concrete samples. A 28-day tensile strength of all the samples was 96-100% of the tensile strength of the control samples and the setting time was reduced by 30 min which was consistent with a ASTMC191 standard. All samples produced and cured with treated waste water did not have a significant effect on water absorption, slump and surface electrical resistivity tests. However, compressive strength at 21 days of concrete samples using 300 kg/m(3) of cement in rapid freezing and thawing conditions was about 11% lower than concrete samples made with drinking water.

  19. Treatment of organized industrial zone wastewater by MBR: First results for KOIZ

    OpenAIRE

    Özkan, Oktay; Uyanık, İbrahim; Rençber, Mehmet Mükerrem; Oğuz, Merve; Şahin, Uğur; Koyuncu, İsmail

    2018-01-01

    Organized industrial zones (OIZs) in Turkeysolve their wastewater problems by collecting and treating the wastewater usingsome traditional methods (mostly biological) to achieve discharge standards.However, new solutions for water reclamations are needed for the limited watersources, increasing pollution loads to the receiving environments and waterbasins. Membrane bioreactors (MBRs) have recently become more preferable due totheir advantages over the conventional treatment methods by their d...

  20. Electrochemical oxidation of textile industry wastewater by graphite electrodes.

    Science.gov (United States)

    Bhatnagar, Rajendra; Joshi, Himanshu; Mall, Indra D; Srivastava, Vimal C

    2014-01-01

    In the present article, studies have been performed on the electrochemical (EC) oxidation of actual textile industry wastewater by graphite electrodes. Multi-response optimization of four independent parameters namely initial pH (pHo): 4-10, current density (j): 27.78-138.89 A/m(2), NaCl concentration (w): 0-2 g/L and electrolysis time (t): 10-130 min have been performed using Box-Behnken (BB) experimental design. It was aimed to simultaneously maximize the chemical oxygen demand (COD) and color removal efficiencies and minimize specific energy consumption using desirability function approach. Pareto analysis of variance (ANOVA) showed a high coefficient of determination value for COD (R(2) = 0.8418), color (R(2) = 0.7010) and specific energy (R(2) = 0.9125) between the experimental values and the predicted values by a second-order regression model. Maximum COD and color removal and minimum specific energy consumed was 90.78%, 96.27% and 23.58 kWh/kg COD removed, respectively, were observed at optimum conditions. The wastewater, sludge and scum obtained after treatment at optimum condition have been characterized by various techniques. UV-visible study showed that all azo bonds of the dyes present in the wastewater were totally broken and most of the aromatic rings were mineralized during EC oxidation with graphite electrode. Carbon balance showed that out of the total carbon eroded from the graphite electrodes, 27-29.2% goes to the scum, 71.1-73.3% goes into the sludge and rest goes to the treated wastewater. Thermogravimetric analysis showed that the generated sludge and scum can be dried and used as a fuel in the boilers/incinerators.

  1. Combined Industrial Wastewater Treatment in Anaerobic Bioreactor Posttreated in Constructed Wetland

    Science.gov (United States)

    Zeb, Bibi Saima; Mahmood, Qaisar; Jadoon, Saima; Pervez, Arshid; Irshad, Muhammad; Bilal, Muhammad; Bhatti, Zulfiqar Ahmad

    2013-01-01

    Constructed wetland (CW) with monoculture of Arundo donax L. was investigated for the posttreatment of anaerobic bioreactor (ABR) treating combined industrial wastewater. Different dilutions of combined industrial wastewater (20, 40, 60, and 80) and original wastewater were fed into the ABR and then posttreated by the laboratory scale CW. The respective removal efficiencies of COD, BOD, TSS, nitrates, and ammonia were 80%, 78–82%, 91.7%, 88–92%, and 100% for original industrial wastewater treated in ABR. ABR was efficient in the removal of Ni, Pb, and Cd with removal efficiencies in the order of Cd (2.7%) > Ni (79%) > Pb (85%). Posttreatment of the ABR treated effluent was carried out in lab scale CW containing A. donax L. CW was effective in the removal of COD and various heavy metals present in ABR effluents. The posttreatment in CW resulted in reducing the metal concentrations to 1.95 mg/L, 0 mg/L, and 0.004 mg/L for Ni, Pb, and Cd which were within the permissible water quality standards for industrial effluents. The treatment strategy was effective and sustainable for the treatment of combined industrial wastewater. PMID:24396832

  2. Combined Industrial Wastewater Treatment in Anaerobic Bioreactor Posttreated in Constructed Wetland

    Directory of Open Access Journals (Sweden)

    Bibi Saima Zeb

    2013-01-01

    Full Text Available Constructed wetland (CW with monoculture of Arundo donax L. was investigated for the posttreatment of anaerobic bioreactor (ABR treating combined industrial wastewater. Different dilutions of combined industrial wastewater (20, 40, 60, and 80 and original wastewater were fed into the ABR and then posttreated by the laboratory scale CW. The respective removal efficiencies of COD, BOD, TSS, nitrates, and ammonia were 80%, 78–82%, 91.7%, 88–92%, and 100% for original industrial wastewater treated in ABR. ABR was efficient in the removal of Ni, Pb, and Cd with removal efficiencies in the order of Cd (2.7% > Ni (79% > Pb (85%. Posttreatment of the ABR treated effluent was carried out in lab scale CW containing A. donax L. CW was effective in the removal of COD and various heavy metals present in ABR effluents. The posttreatment in CW resulted in reducing the metal concentrations to 1.95 mg/L, 0 mg/L, and 0.004 mg/L for Ni, Pb, and Cd which were within the permissible water quality standards for industrial effluents. The treatment strategy was effective and sustainable for the treatment of combined industrial wastewater.

  3. Analysis of Treated Wastewater Produced from Al-Lajoun Wastewater Treatment Plant, Jordan

    Directory of Open Access Journals (Sweden)

    Waleed Manasreh

    2009-01-01

    Full Text Available Assessment of treated wastewater produced from Al-Lajoun collection tanks of the wastewater treatment plant in Karak province was carried out in term of physical properties, its major ionic composition, heavy metals and general organic content, for both wastewater influent and effluent. Sampling was done in two periods during (2005-2006 summer season and during winter season to detect the impact of climate on treated wastewater quality. Soil samples were collected from Al-Lajoun valley where the treated wastewater drained, to determine the heavy metal and total organic carbon concentrations at same time. The study showed that the treated wastewater was low in its heavy metals contents during both winter and summer seasons, which was attributed to high pH value enhancing their precipitations. Some of the major ions such as Cl-, Na+, HCO33-, Mg2+ in addition to biological oxygen demand and chemical oxygen demand were higher than the recommended Jordanian guidelines for drained water in valleys. The treated wastewater contained some organic compounds of toxic type such as polycyclic aromatic hydrocarbons. Results showed that the soil was low in its heavy metal contents and total organic carbon with distance from the discharging pond, which attributed to the adsorption of heavy metals, total organic carbon and sedimentation of suspended particulates. From this study it was concluded that the treated wastewater must be used in situ for production of animal fodder and prohibit its contact with the surface and groundwater resources of the area specially Al-Mujeb dam where it is collected.

  4. DETERMINATION OF THE QUALITY OF INDUSTRIAL LAUNDRY RAW WASTEWATER

    Directory of Open Access Journals (Sweden)

    Natalia Dąbkowska

    2017-10-01

    Full Text Available Industrial laundries are one of the largest consumers of water, which is associated with significant generation of laundry wastewater. Water is one of the most important technological factors in the laundry industry. The amount of laundry wastewater generated is the result of the quantity of textile laundered and is roughly equal to the amount of technological water used to reduce the losses caused by evaporation. The quality of raw laundry wastewater depends on the quantity of impurities removed during the textile washing process and on the amount and quality of detergents added to the washing bath. The aim of the research was to conduct a determination analysis of raw laundry wastewater from industrial laundry located in Nowe Czarnowo. The subject of the study was raw laundry wastewater cleaned mechanically from a 500 ml autosampler tank to obtain a representative test sample. Raw wastewater quality designations were made using photometric methods Hach Lange's cuvette tests. The following determinations were made: anionic detergents, nonionic detergents, COD, BOD5, chlorides, total phosphate, total nitrogen and total organic carbon. The pH was also determined. On the basis of the obtained results, it can be concluded that industrial laundry wastewater contains organic compounds at the level of 126 to 153 mg/dm3. In addition, the analyzed raw wastewater is characterized by the presence of surfactants such as anionic and nonionic detergents ranging from 11.0 to 54.6 mg/dm3. The increased content of surfactants is closely related to the specific characteristics of industrial laundries. According to the literature, the values of individual indicators of raw laundry wastewater do not deviate from the values found in other types of industrial laundry.

  5. Biological and Irradiation Treatment of Mix Industrial Wastewater in Flood Mitigation Pond at Prai Industrial Zone

    International Nuclear Information System (INIS)

    Khomsaton Abu Bakar; Jamaliah Sharif; Selambakkanu, S.; Ming, T.M.; Natasha Isnin; Hasnul Nizam Osman; Khasmidatul Akma Mohd Khairul Azmi

    2014-01-01

    In this work, activated sludge process and E-Beam was used to treat mixed industrial waste water from mitigation pond A. The objectives of this study to analyze the effect of mix liquor volatile suspended solid (MLVSS) concentration on the properties of wastewater and duration of time taken to achieve steady stage condition for biological treatment. Besides that, effect of electron beam energy on the characteristic of wastewater after irradiation with electron beam machine EPS 3000 was studied as well. The result shows removal percentage of COD, suspended solid and color was linearly proportional with MLVSS. Maximum reduction values recorded for COD, suspended solid and color removal was 69.4, 73.0 and 43.7 % respectively with 3500 mg/l MLVSS at 48 h HRT. In irradiation treatment, significant reduction of COD was obtained with the increase of electron beam energy but the results for suspended solid and color was not favorable. (author)

  6. Decontamination of industrial wastewater from sugarcane crops by combining solar photo-Fenton and biological treatments.

    Science.gov (United States)

    Mendoza-Marín, Claudia; Osorio, Paula; Benítez, Norberto

    2010-05-15

    The department of Valle del Cauca is the region with the largest sugarcane production in Colombia. This agricultural activity uses high quantities of herbicides, mainly Diuron and 2,4-Dichlorophenoxyacetic acid. Wastewater generated in the washing process of spray equipment and empty pesticide containers must be treated to keep natural water sources from being polluted with these pesticides when these effluents are disposed off. Conventional biological treatments are not able to remove recalcitrant substances like Diuron and 2,4-Dichlorophenoxyacetic acid; therefore, it is essential to have alternative treatment systems. In recent years, photocatalytic processes have been proven efficient methods in treating polluted water with recalcitrant organic substances. This study sought to evaluate the efficiency of a coupled treatment constituted for a solar photo-Fenton treatment and a biological system like an immobilized biological reactor to treat industrial wastewater containing pesticides (2,4-Dichlorophenoxyacetic acid and Diuron). The mineralization and degradation of pesticides were followed by measuring the dissolved organic carbon and pesticide concentrations. The results revealed that industrial wastewaters with high Diuron and 2,4-Dichlorophenoxyacetic acid concentrations can be successfully treated by a combined solar photo-Fenton-biological system, achieving mineralization of 79.8% in prepared wastewater and 82.5% in real industrial wastewater by using low Fe(2+) and H(2)O(2) concentrations. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Decontamination of industrial wastewater from sugarcane crops by combining solar photo-Fenton and biological treatments

    International Nuclear Information System (INIS)

    Mendoza-Marin, Claudia; Osorio, Paula; Benitez, Norberto

    2010-01-01

    The department of Valle del Cauca is the region with the largest sugarcane production in Colombia. This agricultural activity uses high quantities of herbicides, mainly Diuron and 2,4-Dichlorophenoxyacetic acid. Wastewater generated in the washing process of spray equipment and empty pesticide containers must be treated to keep natural water sources from being polluted with these pesticides when these effluents are disposed off. Conventional biological treatments are not able to remove recalcitrant substances like Diuron and 2,4-Dichlorophenoxyacetic acid; therefore, it is essential to have alternative treatment systems. In recent years, photocatalytic processes have been proven efficient methods in treating polluted water with recalcitrant organic substances. This study sought to evaluate the efficiency of a coupled treatment constituted for a solar photo-Fenton treatment and a biological system like an immobilized biological reactor to treat industrial wastewater containing pesticides (2,4-Dichlorophenoxyacetic acid and Diuron). The mineralization and degradation of pesticides were followed by measuring the dissolved organic carbon and pesticide concentrations. The results revealed that industrial wastewaters with high Diuron and 2,4-Dichlorophenoxyacetic acid concentrations can be successfully treated by a combined solar photo-Fenton-biological system, achieving mineralization of 79.8% in prepared wastewater and 82.5% in real industrial wastewater by using low Fe 2+ and H 2 O 2 concentrations.

  8. Decontamination of industrial wastewater from sugarcane crops by combining solar photo-Fenton and biological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza-Marin, Claudia; Osorio, Paula [Department of Chemistry, Faculty of Science, Universidad del Valle, A.A. 25360 Cali (Colombia); Benitez, Norberto, E-mail: lubenite@univalle.edu.co [Department of Chemistry, Faculty of Science, Universidad del Valle, A.A. 25360 Cali (Colombia)

    2010-05-15

    The department of Valle del Cauca is the region with the largest sugarcane production in Colombia. This agricultural activity uses high quantities of herbicides, mainly Diuron and 2,4-Dichlorophenoxyacetic acid. Wastewater generated in the washing process of spray equipment and empty pesticide containers must be treated to keep natural water sources from being polluted with these pesticides when these effluents are disposed off. Conventional biological treatments are not able to remove recalcitrant substances like Diuron and 2,4-Dichlorophenoxyacetic acid; therefore, it is essential to have alternative treatment systems. In recent years, photocatalytic processes have been proven efficient methods in treating polluted water with recalcitrant organic substances. This study sought to evaluate the efficiency of a coupled treatment constituted for a solar photo-Fenton treatment and a biological system like an immobilized biological reactor to treat industrial wastewater containing pesticides (2,4-Dichlorophenoxyacetic acid and Diuron). The mineralization and degradation of pesticides were followed by measuring the dissolved organic carbon and pesticide concentrations. The results revealed that industrial wastewaters with high Diuron and 2,4-Dichlorophenoxyacetic acid concentrations can be successfully treated by a combined solar photo-Fenton-biological system, achieving mineralization of 79.8% in prepared wastewater and 82.5% in real industrial wastewater by using low Fe{sup 2+} and H{sub 2}O{sub 2} concentrations.

  9. Pulse electro-coagulation application in treating dibutyl phthalate wastewater.

    Science.gov (United States)

    Wang, Tao; Liu, Tianqing

    2017-09-01

    Pulse electro-coagulation (PEC) was applied to treat plastic factory wastewater in this study. One representative plasticizer molecule was chosen for the synthetic wastewater: dibutyl phthalate (DBP). Experiments demonstrated that PEC exhibits superior economic efficiency and removal efficiency compared to traditional electro-coagulation in wastewater treatment. Experimental data also indicated that at a given current density, compared with the aluminum electrode, the iron electrode could more efficiently remove DBP from wastewater. With an initial pH of 8-9, the required energy was 2.5 kWh m -3 for 75% DBP removal in the case of iron as the anode type. In general, the pollutants have been successfully reduced to environmentally acceptable levels under the following operating conditions: iron as the anode type, interelectrode distance of 10 mm, duty cycle of 0.6, pH of 8-9 and current density of 15 mA cm -2 for PEC time >15 min.

  10. Evaluation of photocatalytic treatment of industrial wastewater using solar energy

    International Nuclear Information System (INIS)

    Restrepo, Gloria Maria; Rios, Luis A; Marin, Juan Miguel; Montoya, Juan Felipe; Velasquez, Jorge Armando

    2008-01-01

    Wastewater of a chemical industry was treated in a photocatalytic process, using a solar photo-reactor made of glass corrugated flat plates that had been set in cascade and using Titanium Dioxide (Degussa p-25) as photocatalyst that is supported on each one of them in film form. the influence of three variables in the decontamination efficiency were studied: amount of H 2 O 2 , volume of water and amount of dispersed TiO 2 , by means of the accomplishment of fifteen experiments carried out in discontinuous operation mode by a period of 5 hours for each test. The obtained results allow establishing that the FH is a viable technology of treatment like previous stage to a biological treatment since percentage of reduction in the DQO varies between 6 and 46% and was managed to reach a biodegradable effluent in all tests

  11. Whole effluent assessment of industrial wastewater for determination of bat compliance: Part 1: Paper manufacturing industry.

    Science.gov (United States)

    Gartiser, Stefan; Hafner, Christoph; Hercher, Christoph; Kronenberger-Schäfer, Kerstin; Paschke, Albrecht

    2010-05-01

    The applicability of the Whole Effluent Assessment concept for the proof of compliance with the "best available techniques" has been analysed with paper mill wastewater from Germany by considering its persistency (P), potentially bio-accumulative substances (B) and toxicity (T). Twenty wastewater samples from 13 paper mills using different types of cellulose fibres as raw materials have been tested in DIN or ISO standardised bioassays: the algae, daphnia, luminescent bacteria, duckweed (Lemna), fish-egg and umu tests with lowest ineffective dilution (LID) as test result. The potentially bio-accumulative substances (PBS) were determined by solid-phase microextraction and referred to the reference compound 2,3-dimethylnaphthalene. Usually, a primary chemical-physical treatment of the wastewater was followed by a single or multi-stage biological treatment. One indirectly discharged wastewater sample was pre-treated biologically in the Zahn-Wellens test before determining its ecotoxicity. No toxicity or genotoxicity at all was detected in the acute daphnia and fish egg as well as the umu assay. In the luminescent bacteria test, moderate toxicity (up to LIDlb=6) was observed. Wastewater of four paper mills demonstrated elevated or high algae toxicity (up to LIDA=128), which was in line with the results of the Lemna test, which mostly was less sensitive than the algae test (up to LIDDW=8). One indirectly discharged wastewater sample was biodegraded in the Zahn-Wellens test by 96% and was not toxic after this treatment. Low levels of PBS have been detected (median 3.27 mmol L(-1)). The colouration of the wastewater samples in the visible band did not correlate with algae toxicity and thus is not considered as its primary origin. Further analysis with a partial wastewater stream from thermomechanically produced groundwood pulp (TMP) revealed no algae or luminescent bacteria toxicity after pre-treatment of the sample in the Zahn-Wellens test (chemical oxygen demand

  12. The Effective Electrolytic Recovery of Dilute Copper from Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    Teng-Chien Chen

    2013-01-01

    Full Text Available Electroplating copper industry was discharged huge amount wastewater and cause serious environmental and health damage in Taiwan. This research applied electrical copper recovery system to recover copper metal. In this work, electrotreatment of a industrial copper wastewater ([Cu] = 30000 mg L−1 was studied with titanium net coated with a thin layer of RuO2/IrO2 (DSA reactor. The optimal result for simulated copper solution was 99.9% copper recovery efficiency in current density 0.585 A/dm2 and no iron ion. Due to high concentration of iron and chloride ions in real industrial wastewater, the copper recovery efficiency was down to 60%. Although, the copper recovery efficiency was not high as simulated copper solution, high environmental economic value was included in the technology. The possibility of pretreating the wastewater with iron is the necessary step, before the electrical recovery copper system.

  13. Soil Chemistry after Irrigation with Treated Wastewater in Semiarid Climate

    Directory of Open Access Journals (Sweden)

    Pedro Carlos Pacheco de Oliveira

    2016-01-01

    Full Text Available ABSTRACT Soil irrigation using treated wastewater in the Brazilian semiarid region is a promising practice as this area currently faces water scarcity and pollution of water resources by domestic sewage. The aim of this study was to evaluate the use of treated wastewater in drip irrigation and its effect on the chemistry of soil cultivated with squash (Cucurbita maxima Duch. Coroa IAC and to verify whether there was an increase in soil salinity under a semiarid climate. The experiment was conducted for 123 days on a farm close to the sewage treatment plant, in a randomized block design with five treatments and four replications. The treatments consisted of two irrigation water depths (100 and 150 % of the evapotranspiration, two applications of gypsum to attenuate wastewater sodicity (0 and 5.51 g per plant, and a control treatment with no application of wastewater or gypsum. During the experiment, treated wastewater and soil gravitational water, at a depth of 0.40 m, were collected for measurement of Na+, K+, Ca2+, Mg2+, NO−3, NH4+, Cl− , alkalinity, electrical conductivity, pH and sodium adsorption ratio. At the end of the experiment, soil samples were collected at depths of 0.00-0.10, 0.10-0.20, and 0.20-0.40 m; and pH, total N, organic C, exchangeable cations and electrical conductivity of the saturation extract (CEs were analyzed. Besides an increase in pH and a reduction in total N, the irrigation with wastewater reduces soil salinity of the naturally salt-rich soils of the semiarid climate. It also led to soil sodification, in spite of the added gypsum, which indicates that irrigation with wastewater might require the addition of greater quantities of gypsum to prevent physical degradation of the soil.

  14. BIOREMOVAL OF LEAD IN INDUSTRIAL WASTEWATER BY MICROALGAE

    Directory of Open Access Journals (Sweden)

    M. RANITHA

    2016-07-01

    Full Text Available The removal of heavy metals from our environment especially wastewater is now shifting from the use of conventional removal method such as chemical precipitation, coagulation and membrane filtration to the use of bioremoval method. The presence of heavy metals in the environment is of major concern because of their toxicity, bioaccumulating tendency, and threat to human life and the environment. In recent years, many low cost sorbents such as microalgae, fungi bacteria and lignocellulosic agricultural by-products have been investigated for their biosorption capacity towards heavy metals. In this project, the focus is on bioremoval of heavy metals in wastewater using marine microalgae. The study will be emphasize on the efficiency of two marine microalgae named Nannochloropsis oculata and Tetraselmis chuii in treating the Lead (Pb content in industrial wasterwater. An experiment on the effect of various Pb concentration (10/20/40/60/80/100mg/L towards the microalgae has been studied. The obtained result showed that the content of chlorophyll-A in the microalgae sample, after 7 days of exposures to Pb, decreased as the Pb concentration increased. Besides that, Tetraselmis chuii was found to be more sensitive compared to Nannochloropsis oculata where both were able to tolerate the Pb concentration of up to only 20mg/L and 60mg/L, respectively.

  15. The role of natural wood constituents on the anaerobic treatability of forest industry wastewaters

    NARCIS (Netherlands)

    Sierra - Alvarez, R.

    1990-01-01

    Anaerobic treatment has been shown to be an efficient and energy conserving method for treating various types of readily biodegradable non-inhibitory forest industry wastewaters. However, the high toxicity of paper mill effluents derived from chemical wood processing operations has hampered

  16. Treatment of anaerobically treated domestic wastewater using rotating biological contactor

    NARCIS (Netherlands)

    Tawfik, A.; Klapwijk, A.; El-Gohary, F.; Lettinga, G.

    2002-01-01

    A small-scale pilot plant consisting of a three-stage RBC has been investigated for the removal of E. coli, COD fractions and ammonia from the effluent of an UASB reactor treating domestic wastewater. The results obtained reveal that a three-stage system operated at a HRT of 3.0 h represents an

  17. Qualitative monitoring of a treated wastewater reuse extensive ...

    African Journals Online (AJOL)

    The WWTP producing this effluent treated wastewater from one of the most popular European tourist resorts on the north coast of the island of Crete, at the southernmost point of Greece. Crete is a semi-arid region where 80 % of the freshwater resources are consumed by agriculture. More than 3 000 000 tourists visit the ...

  18. Impact of treated wastewater for irrigation on soil microbial communities

    Science.gov (United States)

    The use of treated wastewater (TWW) for irrigation has been suggested as an alternative to use of fresh water because of the increasing scarcity of fresh water in arid and semiarid regions of the world. However, significant barriers exist to widespread adoption due to some potential contaminants tha...

  19. Wastewater treatment of pulp and paper industry: a review.

    Science.gov (United States)

    Kansal, Ankur; Siddiqui, Nihalanwar; Gautam, Ashutosh

    2011-04-01

    Pulp and paper industries generate varieties of complex organic and inorganic pollutants depending upon the type of the pulping process. A state-of-art of treatment processes and efficiencies of various wastewater treatment is presented and critically reviewed in this paper. Process description, source of wastewater and their treatment is discussed in detail. Main emphasis is given to aerobic and anaerobic wastewater treatment. In pulp and paper mill wastewater treatment aerobic treatment includes activated sludge process, aerated lagoons and aerobic biological reactors. UASB, fluidized bed, anaerobic lagoon and anaerobic contact reactors are the main technologies for anaerobic wastewater treatment. It is found that the combination of anaerobic and aerobic treatment processes is much efficient in the removal of soluble biodegradable organic pollutants. Color can be removed effectively by fungal treatment, coagulation, chemical oxidation, and ozonation. Chlorinated phenolic compounds and adsorable organic halides (AOX) can be efficiently reduced by adsorption, ozonation and membrane filtration techniques.

  20. Sustainable Agro-Food Industrial Wastewater Treatment Using High Rate Anaerobic Process

    Directory of Open Access Journals (Sweden)

    Yung-Tse Hung

    2013-03-01

    Full Text Available This review article compiles the various advances made since 2008 in sustainable high-rate anaerobic technologies with emphasis on their performance enhancement when treating agro-food industrial wastewater. The review explores the generation and characteristics of different agro-food industrial wastewaters; the need for and the performance of high rate anaerobic reactors, such as an upflow anaerobic fixed bed reactor, an upflow anaerobic sludge blanket (UASB reactor, hybrid systems etc.; operational challenges, mass transfer considerations, energy production estimation, toxicity, modeling, technology assessment and recommendations for successful operation

  1. Treatment of leather industrial wastewater via combined advanced oxidation and membrane filtration.

    Science.gov (United States)

    Abdel-Shafy, Hussein I; El-Khateeb, Mohamed A; Mansour, Mona S M

    The liming/unhairing operation is among the important processes of the leather industry. It generates large amounts of effluent that are highly loaded with organic hazard wastes. Such effluent is considered one of the most obnoxious materials in the leather industry, causing serious environmental pollution and health risks. The effluent is characterized by high concentrations of the pollution parameters. Conventional chemical and/or biological treatment of such wastewater is inefficient to meet the required limits of standard specifications, due to the presence of resistant and toxic compounds. The present investigation deals with an effective treatment approach for the lime/unhair effluent using the Fenton reaction followed by membrane filtration. The experiment was extended to a laboratory pilot-scale in a continuous treatment study. In this study the raw wastewater was treated with the predetermined Fenton's optimum dose followed by membrane filtration. The wastewater was efficiently treated and the final effluent met the standards for unrestricted water reuse.

  2. Treatability study of pesticide-based industrial wastewater.

    Science.gov (United States)

    Shah, Kinnari; Chauhan, L I; Galgale, A D

    2012-10-01

    This paper finds out appropriate treatment methods for wastewater of an Organophosphorus viz, chloropyrifos pesticide manufacturing industry. The characterization of wastewater generated during trial production of chloropyrifos was carried out. Based on the characterization of wastewater, various treatability studies were conducted. The most desirable results were obtained with treatment scheme employing acidification, chlorination with NaOCl, suspended growth biological treatment, chemical precipitation for phosphorous removal and activated carbon treatment. Acidification of wastewater helps in by-product recovery as well as reduction in COD upto 36.26%. Chlorination followed by biological treatment was found to be effective to reduce the COD level by 62.06%. To comply with permissible limits prescribed by Effluent Channel Project Ltd.(ECPL)* and Gujarat Pollution Control Board (GPCB) for discharge of industrial effluent into channel, further treatment in the form of chemical precipitation (for phosphorous removal) and granular activated carbon is suggested.

  3. Recent advances and industrial viewpoint for biological treatment of wastewaters by oleaginous microorganisms.

    Science.gov (United States)

    Huang, Chao; Luo, Mu-Tan; Chen, Xue-Fang; Xiong, Lian; Li, Xiao-Mei; Chen, Xin-De

    2017-05-01

    Recently, technology of using oleaginous microorganisms for biological treatment of wastewaters has become one hot topic in biochemical and environmental engineering for its advantages such as easy for operation in basic bioreactor, having potential to produce valuable bio-products, efficient wastewaters treatment in short period, etc. To promote its industrialization, this article provides some comprehensive analysis of this technology such as its advances, issues, and outlook especially from industrial viewpoint. In detail, the types of wastewaters can be treated and the kinds of oleaginous microorganisms used for biological treatment are introduced, the potential of industrial application and issues (relatively low COD removal, low lipid yield, cost of operation, and lack of scale up application) of this technology are presented, and some critical outlook mainly on co-culture method, combination with other treatments, process controlling and adjusting are discussed systematically. By this article, some important information to develop this technology can be obtained. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Domestic wastewater treated for agricultural reuse

    African Journals Online (AJOL)

    *

    ... filter (AF), a horizontal gravel bed (GB); a constructed wetland (CW) and a series of five polishing ponds were the systems used to treat the UASB reactor effluent. The chemical oxygen demand (COD) data in the post-treatment effluents ranged from 60 to 80 mg.L-1, which means a good efficiency in organic matter removal ...

  5. ODOR REMOVAL IN WASTEWATER TREATED BY ROOTS ZONE BED (WETLANDS

    Directory of Open Access Journals (Sweden)

    Waldir Nagel Schirmer

    2010-05-01

    Full Text Available The wetland is a system that uses the roots plants (macrophyte in the domestic wastewater treatment. The mechanisms (physical, chemical and biological ones of organic matter stabilization of effluent and odorous compounds (commonly found in anaerobic biological degradation involve soil, microorganisms and plants. This work uses olfactometry (technical of odors analysis as tool in the evaluation of the odor remotion of sewage treated by Root Zone Sewage Treatment Station (RZSTS in an rural community of Irati City (Brazil. For a better evaluation of the effectiveness of the odor remotion, the odors (rather and downstream treatment has been evaluated in the three olfactometric categories (intensity, character and hedonic tone, according to European standards. The results had pointed that wastewater treated still presented perceivable levels of odor even after significant reduction in intensity (the reduction in the category “very strong” was 89,3% between the entrance and outlet wastewater of the macrophyes station. Moreover, “offensive” category was cited by the jury in the two effluent (entrance and outlet one, with 91% and 40% of answers, respectively; however, in this same question, the wastewater treated presented less aggressive and unpleasant odors. In a general way, the station proposed revealed efficiency in odorous compounds stabilization by anaerobic biological degradation.

  6. Food industrial wastewater reuse by membrane bio-reactor

    Directory of Open Access Journals (Sweden)

    Patthanant Natpinit

    2007-11-01

    Full Text Available The objective of this investigation was to study the possibility and performance of treating food industrial wastewater by Membrane BioReactor (MBR. In addition, the effluent of MBR was treated by Reverse Osmosis system (RO to reuse in boiler or cooling tower. The membranes of hollow fiber type were filled in the aerobic tank with aerobe bacteria. The total area of membrane 6 units was 630 m2 so the flux of the operation was 0.25 m/d or 150 m3/d. The spiral wound RO was operated at 100 m3/d of influent and received 72 m3/d of permeate. The sludge volume (MLSS of MBR was maintained at 8,000-10,000 mg/l. The average COD and SS of MBR influent were 600 mg/l and 300 mg/l respectively. After treating by MBR, COD and SS of effluent were maintained at less than 100 mg/l and less than 10 mg/l respectively. In the same way, COD and SS of RO permeate were less than 10 mg/l and less than 5 mg/l respectively.

  7. Wastewater screening method for evaluating applicability of zero-valent iron to industrial wastewater

    International Nuclear Information System (INIS)

    Lee, J.W.; Cha, D.K.; Oh, Y.K.; Ko, K.B.; Jin, S.H.

    2010-01-01

    This study presents a screening protocol to evaluate the applicability of the ZVI pretreatment to various industrial wastewaters of which major constituents are not identified. The screening protocol consisted of a sequential analysis of UV-vis spectrophotometry, high-performance liquid chromatograph (HPLC), and bioassay. The UV-vis and HPLC analyses represented the potential reductive transformation of unknown constituents in wastewater by the ZVI. The UV-vis and HPLC results were quantified using principal component analysis (PCA) and Euclidian distance (ED). The short-term bioassay was used to assess the increased biodegradability of wastewater constituents after ZVI treatment. The screening protocol was applied to seven different types of real industrial wastewaters. After identifying one wastewater as the best candidate for the ZVI treatment, the benefit of ZVI pretreatment was verified through continuous operation of an integrated iron-sequencing batch reactor (SBR) resulting in the increased organic removal efficiency compared to the control. The iron pretreatment was suggested as an economical option to modify some costly physico-chemical processes in the existing wastewater treatment facility. The screening protocol could be used as a robust strategy to estimate the applicability of ZVI pretreatment to a certain wastewater with unknown composition.

  8. Constructed wetlands in the treatment of agro-industrial wastewater: A review

    Directory of Open Access Journals (Sweden)

    Sultana Mar-Yam

    2015-01-01

    Full Text Available Due to their simplicity and low operation cost, constructed wetlands are becoming more prevalent in wastewater treatment all over the world. Their range of applications is no longer limited to municipal wastewater but has expanded to the treatment of heavily polluted wastewaters such as agro-industrial effluents. This paper provides a comprehensive literature review of the application of constructed wetlands in treating a variety of agro-industrial wastewaters, and discusses pollutant surface loads and the role of constructed wetland type, prior-treatment stages and plant species in pollutant removal efficiency. Results indicate that constructed wetlands can tolerate high pollutant loads and toxic substances without losing their removal ability, thus these systems are very effective bio-reactors even in hostile environments. Additionally, the review outlines issues that could improve pollutant treatment efficiency and proposes design and operation suggestions such as suitable vegetation, porous media and constructed wetland plain view. Finally, a decision tree for designing constructed wetlands treating agro-industrial wastewaters provides an initial design tool for scientists and engineers.

  9. Effects on crops of irrigation with treated municipal wastewaters.

    Science.gov (United States)

    Fasciolo, G E; Meca, M I; Gabriel, E; Morábito, J

    2002-01-01

    The fertilizing potential of treated municipal wastewater (oxidation ditch) and crop sanitary acceptability for direct human consumption were evaluated in Mendoza, Argentina. Two experiments were performed on a pilot plot planted with garlic (1998) and onions (1999) using furrow irrigation with three types of water in 10 random blocks: treated effluent (2.5 x 10(3) MPN Escherichia coli/100 ml, 3 helminth eggs/l, and Salmonella (positive); and well water (free of microorganisms), with and without fertilizer. Two responses were evaluated: (1) crop yield, and (2) crop microbiological quality for human consumption at different times after harvest. Crop yields were compared using Variance analysis. Crops' sanitary acceptability was assessed using a two-class sampling program for Salmonella (n=10; c=0), and a three-class program for E. coli (n=5, c=2, M=10(3) and m=10 MPN/g) as proposed by the International Commission on Microbiological Specifications for Foods (ICMSF) for fresh vegetables. Wastewater irrigation acted as well water with fertilizer, increasing garlic and onion yields by 10% and 15%, respectively, compared to irrigation with well water with no fertilizer. Wastewater-irrigated garlic reached sanitary acceptability 90 days after harvest, once attached roots and soil were removed. Onions, which were cleaned immediately after harvest, met this qualification earlier than garlic (55 days). Neither the wastewater-irrigated crops nor the control crops were microbiologically acceptable for consumption raw at harvest.

  10. Oxidation of pharmaceuticals by chlorine dioxide in biologically treated wastewater

    DEFF Research Database (Denmark)

    Hey, G.; Grabic, R.; Ledin, A.

    2012-01-01

    Biologically treated wastewater spiked with a mixture of 56 active pharmaceutical ingredients (APIs) was treated with 0–20mg/L chlorine dioxide (ClO2) solution in laboratory-scale experiments. Wastewater effluents were collected from two wastewater treatment plants in Sweden, one with extended...... nitrogen removal (low COD) and one without (high COD). About one third of the tested APIs resisted degradation even at the highest ClO2 dose (20mg/L), while others were reduced by more than 90% at the lowest ClO2 level (0.5mg/L). In the low COD effluent, more than half of the APIs were oxidized at 5mg/L Cl......O2, while in high COD effluent a significant increase in API oxidation was observed after treatment with 8mg/L ClO2. This study illustrates the successful degradation of several APIs during treatment of wastewater effluents with chlorine dioxide....

  11. The use of hydrologically altered wetlands to treat wastewater in coastal Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    Breaux, A.M.

    1992-01-01

    Two major environmental problems currently affecting Louisiana are a high rate of coastal wetland loss and high levels of surface water pollution. The application of secondarily treated wastewater to wetlands is proposed to dealing with these problems. The benefits of wetland wastewater treatment include improved surface water quality, increased accretion rates to balance subsidence, improved plant productivity, and decreased capital outlays for conventional engineering treatment systems. Wetland treatment systems can be designed and operated to restore deteriorating wetlands to previous levels of productivity. Hydrologically altered wetlands in the Louisiana coastal zone are appropriate for receiving municipal and some industrial effluent. While the US EPA has determined that wetland wastewater treatment is effective in treating municipal effluent, it has discouraged the use of natural wetlands for this purpose. As a result, hydrologically altered wetlands in the Louisiana coastal zone are being neglected and ultimately lost, while scarce funds are used to construct artificial wetlands to treat municipal effluent. Effluent discharge to existing wetlands can be incorporated into a comprehensive management plan designed to increase sediment and nutrient input into subsiding wetlands in the Louisiana coastal zone. Secondarily treated effluent discharged from industrial and municipal facilities in the Louisiana coastal zone were reviewed for suitability for wetland wastewater treatment. Selection criteria for wetland treatment systems were developed for both dischargers and receiving wetlands. Designs for two potential case studies based on established selection criteria for wetland wastewater treatment systems are presented. An economic analysis of the four case studies indicates a high potential for financial savings when wetlands replace conventional engineering methods for tertiary treatment.

  12. Wetlands for Industrial Wastewater Treatment at the Savannah River Site

    International Nuclear Information System (INIS)

    Gladden, J.B.

    2002-01-01

    The A-01 effluent outfall, which collects both normal daily process flow and stormwater runoff from a industrial park area, did not meet the South Carolina Department of Health and Environmental Control (SCDHEC) National Pollutant Discharge Elimination System (NPDES) permit limits for metals, toxicity, and total residual chlorine at the outfall sampling point. Copper was the constituent of primary concern and the effluent consistently failed to meet that NPDES limit. Installation of a constructed wetland system including a basin to manage stormwater surges was required to reduce the problematic constituent concentrations to below the NPDES permit limits before the effluent reaches the sampling point. Both bench-scale and on-site pilot scale physical models were constructed to refine and optimize the preliminary design as well as demonstrate the effectiveness of this approach prior to construction, which was completed in October 2000. The constructed treatment wetlands system has prov en its ability to treat industrial wastewaters containing metals with low O and M costs since there are no mechanical parts. With an anticipated life of over 50 years, this system is exceptionally cost effective

  13. Heat from domestic and industrial wastewater

    International Nuclear Information System (INIS)

    Gasharov, S.

    2006-01-01

    More than 40% of the energy produced in the world is utilized by the building sector - mainly for heating of buildings and water. Different methods are used for the reduction of this energy - new thermo-isolating materials in the new building process, treating of the already existing buildings with thermo-isolating coverings, new aluminium and PVC frames for the windows, application of different solar equipment. At the same time the energy necessary for the heating of water for domestic usage increases permanently. Besides, the need for hot water is constant - every day, all the years. Here the possibilities for saving energy are more limited - limitation of the quantities of consumed hot water (but the statistics show just the opposite tendency), or recycling of the residual heat that is contained in the sewerage hot water, domestic and industrial. This solution is possible and technologically feasible through the usage of thermo-exchanging devices and thermo-pumps, and a process in which only the heat / thermal energy / of the sewerage water is accumulated, and then returned to the equipment for heating water. The heating module could be repaid for a period of 3.5 - 4 years as a result of the savings of thermal energy, which is economically very advantageous. And last but not least, the process has favourable ecological effect, following the world's latest tendencies. (author)

  14. Validation and implementation of model based control strategies at an industrial wastewater treatment plant.

    Science.gov (United States)

    Demey, D; Vanderhaegen, B; Vanhooren, H; Liessens, J; Van Eyck, L; Hopkins, L; Vanrolleghem, P A

    2001-01-01

    In this paper, the practical implementation and validation of advanced control strategies, designed using model based techniques, at an industrial wastewater treatment plant is demonstrated. The plant under study is treating the wastewater of a large pharmaceutical production facility. The process characteristics of the wastewater treatment were quantified by means of tracer tests, intensive measurement campaigns and the use of on-line sensors. In parallel, a dynamical model of the complete wastewater plant was developed according to the specific kinetic characteristics of the sludge and the highly varying composition of the industrial wastewater. Based on real-time data and dynamic models, control strategies for the equalisation system, the polymer dosing and phosphorus addition were established. The control strategies are being integrated in the existing SCADA system combining traditional PLC technology with robust PC based control calculations. The use of intelligent control in wastewater treatment offers a wide spectrum of possibilities to upgrade existing plants, to increase the capacity of the plant and to eliminate peaks. This can result in a more stable and secure overall performance and, finally, in cost savings. The use of on-line sensors has a potential not only for monitoring concentrations, but also for manipulating flows and concentrations. This way the performance of the plant can be secured.

  15. Opportunities and Challenges for Water and Wastewater Industries to Provide Exchangeable Services

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, Bethany [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hunsberger, Randolph [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-11-13

    Water and wastewater treatment plants and distribution systems use significant amounts of energy, around 2 - 4% of the total electricity used in the US, and their energy use is projected to increase as populations increase and regulations become more stringent. Water and wastewater systems have largely been disconnected from the electric utilities' efforts to improve energy efficiency and provide energy efficiency and provide grid services, likely because their core mission is to provide clean water and treated wastewater. Energy efficiency has slowly crept into the water and wastewater industry as the economic benefit has become more apparent, but there is still potential for significant improvement. Some of the larger, more progressive water utilities are starting to consider providing grid services; however, it remains a foreign concept to many. This report explores intrinsic mechanisms by which the water and wastewater industries can provide exchangeable services, the benefit to the parties involved, and the barriers to implementation. It also highlights relevant case studies and next steps. Although opportunities for increasing process efficiencies are certainly available, this report focuses on the exchangeable services that water and wastewater loads can provide to help maintain grid reliability, keep overall costs down, and increase the penetration of distributed renewables on the electric grid. These services have potential to provide water utilities additional value streams, using existing equipment with modest or negligible upgrade cost.

  16. Integrating the Anaerobic Process with Ultrafiltration in Meat Industry Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Kwarciak-Kozłowska Anna

    2014-12-01

    Full Text Available The aim of this paper was to study meat industry wastewater treatment efficiency during fermentation process in ASBR reactor and post-treatment in UF process. The anaerobic process obtained a considerable degree of the removal of organic pollutants from raw wastewater designated as COD (73.3%, BOD (71.4% and TOC (83.2%. The concentrations of COD and BOD were 435 and 443 mg/dm3, respectively. The value of TOC reached a level of 136 mg/dm3. Generated biogas in the methane fermentation process of wastewater from meat industry plants was characterized by high methane content (80.9% vol.. In the final part of the experiment, the UF process was used in order to post-treating effluent from ASBR reactor. During the UF process, COD, BOD and TOC parameters were removed at 67.2%, 68% and 70.4%, respectively.

  17. Pre-treatment of high oil and grease pet food industrial wastewaters using immobilized lipase hydrolyzation.

    Science.gov (United States)

    Jeganathan, Jeganaesan; Bassi, Amarjeet; Nakhla, George

    2006-09-01

    Wastewaters generating from pet food industries contain high concentration of oil and grease (O&G), which is difficult to treat through conventional biological treatment systems. In this study, the hydrolysis of O&G originating from pet food industrial wastewater was evaluated. Candida rugosa lipase was immobilized in calcium alginate beads and applied in the hydrolysis experiment. Results showed that approximately 50% of the O&G was hydrolyzed due to the enzyme activity. A significant increment in COD and VFA production was also observed. The immobilized lipase activity was confirmed with p-nitrophenyl palmitate (pNPP) before and after O&G hydrolysis. During the 3-day experiment, approximately 65% of the beads were recovered and after the hydrolysis, approximately 70% of the enzyme activity remained in the beads. This study shows the potential of immobilized lipase as a pre-treatment step in biological treatment of pet food manufacturing wastewater.

  18. Pre-treatment of high oil and grease pet food industrial wastewaters using immobilized lipase hydrolyzation

    International Nuclear Information System (INIS)

    Jeganathan, Jeganaesan; Bassi, Amarjeet; Nakhla, George

    2006-01-01

    Wastewaters generating from pet food industries contain high concentration of oil and grease (O and G), which is difficult to treat through conventional biological treatment systems. In this study, the hydrolysis of O and G originating from pet food industrial wastewater was evaluated. Candida rugosa lipase was immobilized in calcium alginate beads and applied in the hydrolysis experiment. Results showed that approximately 50% of the O and G was hydrolyzed due to the enzyme activity. A significant increment in COD and VFA production was also observed. The immobilized lipase activity was confirmed with p-nitrophenyl palmitate (pNPP) before and after O and G hydrolysis. During the 3-day experiment, approximately 65% of the beads were recovered and after the hydrolysis, approximately 70% of the enzyme activity remained in the beads. This study shows the potential of immobilized lipase as a pre-treatment step in biological treatment of pet food manufacturing wastewater

  19. The use of constructed wetlands for the treatment of industrial wastewater

    Directory of Open Access Journals (Sweden)

    Skrzypiecbcef Katarzyna

    2017-09-01

    Full Text Available Constructed wetlands are characterized by specific conditions enabling simultaneous various physical and biochemical processes. This is the result of specific environment for the growth of microorganisms and hydrophytes (aquatic and semiaquatic plants which are capable of living in aerobic, anaerobic and facultative anaerobic conditions. Their interaction contributes to the intensification of oxidation and reduction responsible for the removal and retention of pollutants. These processes are supported by sorption, sedimentation and assimilation. Thanks to these advantages, treatment wetland systems have been used in communal management for over 50 years. In recent years, thanks to its advantages, low operational costs and high removal efficiency, there is growing interest in the use of constructed wetlands for the treatment or pre-treatment of various types of industrial wastewater. The study analyzes current use of these facilities for the treatment of industrial wastewater in the world. The conditions of use and efficiency of pollutants removal from readily and slowly biodegradable wastewater, with special emphasis on specific and characteristic pollutants of particular industries were presented. The use of subsurface horizontal flow beds for the treatment of industrial wastewater, among others from crude oil processing, paper production, food industry including wineries and distillery, olive oil production and coffee processing was described. In Poland constructed wetlands are used for the treatment of sewage and sludge from milk processing in pilot scale or for dewatering of sewage sludge produced in municipal wastewater treatment plant treating domestic sewage with approximately 40% share of wastewater from dairy and fish industry. In all cases, constructed wetlands provided an appropriate level of treatment and in addition the so-called ecosystem service.

  20. Purification and treatment of industrial wastewater by electron beam process: it's potential and effectiveness evaluation

    International Nuclear Information System (INIS)

    Zulkafli Ghazali; Khomsaton Abu Bakar; Ting Teo Ming; Siti Aiasah Hashim; Khairul Zaman Mohd Dahlan

    2002-01-01

    Demand for water has grown dramatically globally. We have seen how acute is the demand for treated water in Malaysia during dry spell of late. Between 1900 and 1995, water consumption increased by over six times, globally, more than double the rate of population growth. This rapid growth in water demand is due to the increasing reliance on irrigation to achieve food security, the growth of industries, and the increasing use for domestic purposes. Given the seriousness of the situation and future risk of crises, there is an urgent need to develop the water-efficient technologies including economical treatment methods of wastewater and polluted water. Electron beam treatment (E-Beam treatment) is a comparatively new method of wastewater purification. E-beam treatment is also an environment-friendly approach for the cleanup of contaminated groundwater and industrial wastewater. E-beam treatment treats multi-components waste streams and does not require any hazardous chemical additives nor does it create any secondary wastes. It uses fast formation of short-lived reactive particles, which are capable of efficient decomposition of pollutants inside wastewater. This paper highlights the practical treatment of wastewater using E-Beam method that gives essential conveniences and advantages of the followings: - strongest reducing and oxidizing agents; - universality and interchangeability of redox agents; - variety of paths for pollutant conversion; - process controllability; - wide choice of equipment and technological regimes; - compatibility with conventional methods. (Author)

  1. Occurrence of estrogenic effects in sewage and industrial wastewaters in Beijing, China

    International Nuclear Information System (INIS)

    Ma Mei; Rao Kaifeng; Wang Zijian

    2007-01-01

    Estrogenic potencies of the effluents or water samples from wastewater treatment plants (WWTPs), industries and hospitals and some receiving rivers in Beijing city were estimated by using a human estrogen receptor recombinant yeast assay. Estrogenic activity of industrial wastewaters was found to range from 0.1 to 13.3 ng EEQ/L and decreased to the range of 0.03-1.6 ng EEQ/L after treatment. Estrogenic activity in WWTP influent ranged from 0.3 to 1.7 ng EEQ/L and decreased to the range of 0.05-0.5 ng EEQ/L after treatment. In the receiving river waters, the estrogenic effect range was 0.1-4.7 ng EEQ/L. These data suggest that treated industrial effluents and WWTP effluents of concern are not the only source of estrogenic pollution in surface waters in Beijing city. EEQ levels in Beijing river water are likely attributable to untreated municipal and industrial wastewaters discharged directly into the river. - Estrogenic activity in Beijing river water is attributed to direct discharges of untreated municipal and industrial wastewaters

  2. Genotoxic effects of industrial wastewater on Allium cepa L.

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-04

    May 4, 2009 ... The aim of this research is to study the effects of different concentrations of water on both incoming and outgoing in central biological and chemical wastewater treatment plant in Manisa (Turkey) organized industrial zone (MOIZ) on the Allium cepa L. root meristems, having been rooted in distilled water for ...

  3. Industrial wastewater treatment using natural material as adsorbent ...

    African Journals Online (AJOL)

    Attempts were made to compare the adsorption efficiency of coconut shell-based granular activated carbon with the adsorption efficiency of commercial carbon, Calgon carbon F-300, with respect to adsorption of organic matter from a beverage industrial wastewater. Freundlich adsorption isotherm was used to analyze the ...

  4. Removal of heavy metal from industrial wastewater using hydrogen ...

    African Journals Online (AJOL)

    The batch removal of heavy metals lead (Pb), zinc (Zn) and copper (Cu) from industrial wastewater effluent under different experimental conditions using hydrogen peroxide was investigated. Experimental results indicated that at pH 6.5, pre-treatment analysis gave the following values: Pb 57.63 mg/l, Zn 18.9 mg/l and Cu ...

  5. Local textile industry wastewater effect on freshwater fish species ...

    African Journals Online (AJOL)

    The effect of local tie-dye textile industry wastewater on two selected fish species (Clarias gariepinus and Oreochromis niloticus) of economic importance was investigated using static renewal bioassay method to determine the acute and sub-lethal effects on the test fish species. The physico-chemical parameters of the ...

  6. Anaerobic baffled reactor coupled with chemical precipitation for treatment and toxicity reduction of industrial wastewater.

    Science.gov (United States)

    Laohaprapanona, Sawanya; Marquesa, Marcia; Hogland, William

    2014-01-01

    This study describes the reduction of soluble chemical oxygen demand (CODs) and the removal of dissolved organic carbon (DOC), formaldehyde (FA) and nitrogen from highly polluted wastewater generated during cleaning procedures in wood floor manufacturing using a laboratory-scale biological anaerobic baffled reactor followed by chemical precipitation using MgCI2 .6H20 + Na2HPO4. By increasing the hydraulic retention time from 2.5 to 3.7 and 5 days, the reduction rates of FA, DOC and CODs of nearly 100%, 90% and 83%, respectively, were achieved. When the Mg:N:P molar ratio in the chemical treatment was changed from 1:1:1 to 1.3:1:1.3 at pH 8, the NH4+ removal rate increased from 80% to 98%. Biologically and chemically treated wastewater had no toxic effects on Vibrio fischeri and Artemia salina whereas chemically treated wastewater inhibited germination of Lactuca sativa owing to a high salt content. Regardless of the high conductivity of the treated wastewater, combined biological and chemical treatment was found to be effective for the removal of the organic load and nitrogen, and to be simple to operate and to maintain. A combined process such as that investigated could be useful for on-site treatment of low volumes of highly polluted wastewater generated by the wood floor and wood furniture industries, for which there is no suitable on-site treatment option available today.

  7. Artificial Recharge via Boreholes Using Treated Wastewater: Possibilities and Prospects

    Directory of Open Access Journals (Sweden)

    Kostas Voudouris

    2011-09-01

    Full Text Available Interest in artificial recharge of groundwater using pretreated wastewater continues to increase, especially in semi-arid countries. After the artificial recharge and natural treatment, the water could be extracted through boreholes pumping for direct irrigation. The selection of suitable locations for artificial recharge should be based on hydrogeological conditions, economic evaluation and environmental considerations. Clogging of boreholes that are used for artificial recharge is a serious problem and requires proper planning to reduce it. This paper deals with the investigation of the possibilities and prospects of aquifer recharge via boreholes using treated wastewater. Firstly, the aquifer recharge techniques, the proposed criteria of waste and the clogging effect are presented. Secondly, the possibility of application of artificial recharge in the South-Eastern Mesaoria aquifer of Cyprus is examined. Based on hydrogeological results, artificial recharge using tertiary treated wastewater via boreholes is one of the options available for increasing the groundwater reserves of this aquifer. The recycled water will infiltrate through gravel pack, providing favorable conditions for ventilation and laminar flow due to small water flow velocity. The treatment works include the removal of the fat, oil and grease (FOG and cyanides (CN− content in order to meet the upper acceptable limits.

  8. Optimum parameters for treating coolant wastewater using PVDF-membrane

    Directory of Open Access Journals (Sweden)

    Yuliwati Erna

    2018-01-01

    Full Text Available Chemical oxygen demand (COD removal on ultrafiltration membrane were studied from treating of coolant wastewater. The membranes were fabricated via the dry-jet wet spinning method. The experiment was conducted using synthetic coolant wastewater as effluent, and an experimental set-up consist of membrane reservoir was used throughout the investigation. Deposition and accumulation of suspended solids on the membrane surface during filtration were prohibited with continuous aeration. Membrane performance was measured as well as flux and COD removal efficiency. The RSM was performed to investigate the optimised process conditions for treating coolant wastewater. Results using RSM-approximation have demonstrated the improvement in COD removal of 99.63%. This improvement is achieved by optimised process conditions of mixed liquor suspended solids (MLSS concentration, air bubble flow rate (ABFR, hydraulic retention time (HRT and pH at 6.00 g/L, 3.05 ml/min, 280.50 min, and 6.50 respectively.

  9. 40 CFR 35.2125 - Treatment of wastewater from industrial users.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Treatment of wastewater from industrial... Treatment of wastewater from industrial users. (a) Grant assistance shall not be provided for a project... control or removal of pollutants in wastewater introduced into the treatment works by industrial users...

  10. Managed aquifer recharge using quaternary-treated wastewater: an economic perspective

    KAUST Repository

    Zekri, Slim Mohamed

    2013-10-11

    An excess of 31 million m3/y of tertiary-treated wastewater is expected in Muscat, Oman, by 2015. This paper addresses the technical and cost estimation of managed aquifer recharge after reverse-osmosis treatment. The results indicate that the project is appealing from an economic perspective. The total cost varies between USD 0.353 and USD 0.550 per cubic metre, depending on the cost of electricity, the interest rate and the life span of the project. The project may face rejection from domestic users, who may be unwilling to accept mixing treated wastewater with the current water supply due to health risks. An alternative to indirect potable reuse is the installation of a separate network to service industrial users. © 2013 Taylor & Francis.

  11. Valorization of treated olive mill wastewater in fertigation practice.

    Science.gov (United States)

    Mseddi, Salma; Chaari, Leila; Belaid, Chokri; Chakchouk, Ikram; Kallel, Monem

    2016-08-01

    Olive mill wastewater (OMW) brings about a major environmental problem in Tunisia as well as in the other Mediterranean countries. Its strong organic load and its toxicity due to the presence of complex phenolic compounds have dire effects when applied to soil. To overcome this difficulty, the OMW pretreatment was investigated in the present work using the Fenton oxidation reaction with zero-valent iron. Then, this pretreated wastewater was valorized in fertigation practice. The effects of the addition of different concentrations of both treated and raw OMW on soil and cropping system were investigated. The treatment by Fenton oxidation with zero-valent iron could reduce 50 % of COD and decrease 53 % of phenolic compounds. OMW application had a temporary effect on the soil pH and EC. The results showed that the evolution of soil pH and EC was related to the organic matter of the soil which depends on the spread concentrations of raw or treated OMW. After 15-day incubation period, the soil pH and EC tended to stabilize and return to the control level. Moreover, this stabilization is faster in treated OMW than that in raw OMW especially for concentrations as high as 3 and 4 %. Plants cultivated with treated OMW showed an increase in their germination. The results pointed an improvement in the stem length of plants which is almost similar to that of the control for both pea and tomato, especially for high concentrations of 3 and 4 %.

  12. Industrial wastewater treatment with a bioelectrochemical process: assessment of depuration efficiency and energy production.

    Science.gov (United States)

    Molognoni, Daniele; Chiarolla, Stefania; Cecconet, Daniele; Callegari, Arianna; Capodaglio, Andrea G

    2018-01-01

    Development of renewable energy sources, efficient industrial processes, energy/chemicals recovery from wastes are research issues that are quite contemporary. Bioelectrochemical processes represent an eco-innovative technology for energy and resources recovery from both domestic and industrial wastewaters. The current study was conducted to: (i) assess bioelectrochemical treatability of industrial (dairy) wastewater by microbial fuel cells (MFCs); (ii) determine the effects of the applied organic loading rate (OLR) on MFC performance; (iii) identify factors responsible for reactor energy recovery losses (i.e. overpotentials). For this purpose, an MFC was built and continuously operated for 72 days, during which the anodic chamber was fed with dairy wastewater and the cathodic chamber with an aerated mineral solution. The study demonstrated that industrial effluents from agrifood facilities can be treated by bioelectrochemical systems (BESs) with >85% (average) organic matter removal, recovering power at an observed maximum density of 27 W m -3 . Outcomes were better than in previous (shorter) analogous experiences, and demonstrate that this type of process could be successfully used for dairy wastewater with several advantages.

  13. MICROALGAE BIOMASS PRODUCTION BASED ON WASTEWATER FROM DAIRY INDUSTRY

    Directory of Open Access Journals (Sweden)

    Marcin Dębowski

    2016-05-01

    Full Text Available The goal of this study was to determine the feasibility of culturing high-oil algae biomass based on wastewater from dairy processing plants. The experiments were conducted in laboratory scale with tubular photobioreactor using. The best technological properties were demonstrated for eluates from an anaerobic reactor treating dairy wastewater. The use of a substrate of this type yielded algae biomass concentration at a level of 3490 mg d.m./dm3, with the mean rate of algae biomass growth at 176 mg d.m./dm3∙d. The mean content of oil in the proliferated biomass of algae approximated 20%.

  14. Investigation of Environmental-friendly Technology for a Paint Industry Wastewater Plant in Turkey

    Directory of Open Access Journals (Sweden)

    Pelin YAPICIOĞLU

    2018-02-01

    Full Text Available Paint manufacturing process has several unfavorable aspects to the environment in Turkey. One of these impacts is wastewater treatment. Paint wastewater contains huge amounts of toxic chemical substances, bio refractory compounds, pigments and microorganisms. So, advanced treatment requirement is available to dispose of colour, microorganisms and chemical oxygen demand (COD. The high organic content of wastewater causes serious environmental challenges and contamination for the living organisms and the ecosystem in the receiver media unless it is treated adequately. In this context, the treatment process to be implemented should be preferred in such a way as to give the least damage to the environment. In this study, three treatment scenarios that contain electrocoagulation (Scenario-1, Fenton process (Scenario-2 and membrane distillation (Scenario-3 have been created for wastewater treatment facility of a paint industry in Turkey. For three scenarios, environmental impact assessment has been carried out with Fine-Kinney method. It is aimed to choose best environmental technology before investment. The evaluation results revealed that Scenario-2 has the less environmental impacts that total impact value is 556. Scenario-1 has the highest total impact value as 756, relatively. Total impact value related to Scenario-3 is 637. According to the evaluation results, Fenton process is the best environmental-friendly treatment technology for wastewater treatment of a paint industry in Turkey.

  15. Missouri Industrial Wastewater System Characterization and Analysis, Whiteman Air Force Base

    National Research Council Canada - National Science Library

    Morgan, James

    1998-01-01

    .... The IWSCS analysis indicated industrial wastewater treatment plant unit operations were performing significantly below design expectations and the overall volume and character of industrial waste...

  16. Reuse the pulp and paper industry wastewater by using fashionable technology

    Science.gov (United States)

    Sudarshan, K.; Maruthaiya, K.; Kotteeswaran, P.; Murugan, A.

    2017-10-01

    This proposed method is a promising way, which can be implemented in pulp and paper industries by effective removal of the color and chemical oxygen demand (COD) and the resulting treated water may surely reuse to the other streams. Fourier Transformer Infra Red spectra confirmed the presence of the respective functional groups in the removed pollutants from the wastewater. The efficiency of Non-ferric Alum (NF Alum) and cationic polyacrylamide (C-PAM) with and without power boiler fly ash was also studied. The reduction efficiency of color and chemical oxygen demand (COD) is evaluated at the optimum dosage of NF Alum, fly ash, and C-PAM. At the optimized pH attained from these coagulants using to treat the wastewater, the flocs formation/settling and the pollutant removal efficiency are encouraging and the resulting color of the wastewater is to 40 PtCo units from 330 PtCo units and COD to 66 mg/L from 218 mg/L. While using NF Alum alone with C-PAM for the treatment of wastewater, the highest reduction efficiency of COD is 97 mg/L from 218 mg/L and the color is 60 from 330 PtCo units at pH 4.8 was noted. From these observations, NF Alum and power boiler fly ash with C-PAM can effectively remove the pollutants from the pulp and paper mill wastewater and the water can be reused for other streams.

  17. Application of peat filters for treating milkhouse wastewater

    International Nuclear Information System (INIS)

    Fahie, C.R.; Gagnon, G.A.; Gordon, R.J.

    2002-01-01

    This study investigates the suitability of using peat as a filtering media for the treatment of agricultural wastewater. A full-scale experimental filter system was used to evaluate the ability of the filter system to treat milkhouse wastewater. The full-size modular peat filtration system was installed and monitored on a dairy farm located in Hilden, NS. The peat filter models used in the study were constructed from pre-cast concrete, which are approximately 3.2 m long by 1.8 m wide and 1.0 m high and filled are packed with sphagnum peat moss compacted to a density of 0.15 g cm -3 . Parameters that were monitored include BOD, pH, NO 3 -N, SO 4 , TSS, SRP, and TP. The milkhouse wastewater was characterized by having a BOD 5 of approximately 1500 mg L -1 , an average TSS concentration of 510 mg L -1 and an average SRP concentration of 100 mg L -1 . Removal efficiencies of BOD 5 and TSS were observed to be 59% and 82% respectively. In general, phosphorus removal was poor and subsequent research will examine mechanisms of improving phosphorus removal. (author)

  18. Performance of a UASB reactor treating coffee wet wastewater

    International Nuclear Information System (INIS)

    Guardia Puebla, Yans; Rodríguez Pérez, Suyén; Janet Jiménez Hernández; Sánchez Girón, Víctor

    2014-01-01

    The present work shows the results obtained in the anaerobic digestion process of coffee wet wastewater processing. An UASB anaerobic reactor was operated in single-stage in mesophilic temperature controlled conditions (37±1ºC). The effect of both organic loading rate (OLR) and hydraulic retention time (HRT) in the anaerobic digestion of coffee wet wastewater was investigated. The OLR values considered in the single-stage UASB reactor varied in a range of 3,6-4,1 kgCOD m-3 d-1 and the HRT stayed in a range of 21,5-15,5 hours. The evaluation results show that the best performance of UASB reactor in single-stage was obtained at OLR of 3,6 kg COD m-3 d-1 with an average value of total and soluble COD removal of 77,2% and 83,4%, respectively, and average methane concentration in biogas of 61%. The present study suggests that the anaerobic digestion is suitable to treating coffee wet wastewater. (author)

  19. BOD biosensors for pulp and paper industry wastewater analysis.

    Science.gov (United States)

    Raud, Merlin; Tutt, Marti; Jõgi, Eerik; Kikas, Timo

    2011-08-01

    Two semi-specific microbial biosensors were constructed for the analysis of biochemical oxygen demand (BOD) in high-cellulose-content pulp and paper industry wastewaters. The biosensors were based on living cells of Bacillus subtilis and Paenibacillus sp. immobilized in an agarose gel matrix. Semi-specific microorganisms were isolated from various samples (decaying sawdust and rabbit manure) and were chosen based on their ability to assimilate cellulose. The biosensors were calibrated with the Organization for Economic Cooperation and Development synthetic wastewater, and measurements with different wastewaters were conducted. The response time of biosensors using the steady-state method was 20-25 min, and the service life of immobilized microorganisms was 96 days. Detection limit was 5 mg/l of BOD(7) while linear ranges extended up to 55 and 50 mg/l of the BOD(7) for B. subtilis- and Paenibacillus sp.-based biosensors, respectively. Repeatability and reproducibility of both biosensors were within the limits set by APHA-less than 15.4%. In comparison, both biosensors overestimated the BOD(7) values in paper mill wastewaters and underestimated the BOD(7) in aspen pulp mill wastewater. The semi-specific biosensors are suitable for the estimation of organic pollution derived from cellulose, while the detection of pollution derived from tannins and lignins was minor. Better results in terms of accuracy and repeatability were gained with Paenibacillus sp. biosensor.

  20. Research on safety of reverse osmosis to treat radioactive wastewater

    International Nuclear Information System (INIS)

    Kong Jinsong; Tian Yanjie

    2012-01-01

    The security of reverse osmosis combined with a pretreatment process of disc filtration-ultrafiltration to treat the radioactive wastewater was analyzed and evaluated. Several aspects including reliability and security during operation, maintenance and decommissioning were investigated in this paper. Results showed that safe operation can be ensured by rational process design and scientific management. Estimation on radiation safety showed that the absorbed dose rate is below 0.04 mSv/h on the surface of reverse osmosis module, which can ensure the radiation safety of operators. (authors)

  1. Wastewater Treatment of Stone Cutting Industries by Coagulation Process

    Directory of Open Access Journals (Sweden)

    Mohammad Fahiminia

    2013-09-01

    Full Text Available Background & Aims of the Study: The wastewater created as a result of stone cutting industries enters some pools for re-consumption so that its suspended solids settle by gravity. By taking to account the high volume of water and sludge, treatment of wastewater and removal of sludge cause many problems for stone cutting units. The objective of this study was to determine the quality of wastewater and to investigate the effects of coagulants on suspended solids removal efficiency from wastewater of some stone cutting industries (Qom, Iran. Materials & Methods: In this experimental study, the effects of different doses of coagulants including Alum, poly aluminum chloride, Polymer, Ferric chloride (Fecl3 and Lime on Turbidity, “total suspended solids” (TSS and “total solids” (TS removal were investigated by Jar Test. Removal efficiency of different coagulates was estimated. Results: The results indicated that lime in dose 100 PPM is the best coagulant for turbidity removal and the highest efficiency for TS removal is related to using Alum in dose 100 PPM. Conclusions: Considering the findings of this study, it can be concluded that using coagulants causes reduction in settling time and speeds up the return of water to the consumption cycle of stone cutting factories, and also increases turbidity removal efficiency.

  2. Removal of Chromium from Industrial Wastewater Using Silicon Nanoparticle

    Directory of Open Access Journals (Sweden)

    Laleh Ranandeh Kalankesh

    2015-03-01

    Full Text Available Hexavalent chromium is a pollutant found in surface and underground waters that causes serious environmental hazards. Chromium enters water as a result of industrial activities such as electroplating, dyeing, leather tanning, and metal manufacturing. The objective of the present laboratory-experimental study was to remove chromate from industrial effluents using silicon nanoparticles. The experiments were performed with both simulated synthetic wastewater and true wastewater. Various parameters such as pH, contact time, and different concentrations of Cr(VI and SiO2 were examined. The data obtained were analyzed using the Excel and SPSS Ver. 16. It was found that Cr(VI removal increased with decreasing pH and increasing contact time. The highest Cr(VI removal was achieved at pH=3 and a contact time of 120 minutes. It was also observed that removal observed to obey the Langmuir isotherm and pseudo second-order kinetic models, respectively. The findings indicate that silicon nanoparticles are capable of removeing Cr(VI from industrial effluents. Given the Cr(VI removal efficiency of 93.6% achieved under optimum conditions and  the removal efficiency of 88.6% achieved in real samples, the method may be recommended as a highly efficient one for removing Cr(VI from industrial wastewaters.

  3. WASTEWATER EFFLUENT GENERATED BY GROUT INDUSTRIES IN BRAZIL

    Directory of Open Access Journals (Sweden)

    Fernanda C. Zola

    2016-01-01

    Full Text Available Civil construction has grown inadvertently in Brazil, and, consequently, its demands for raw material. The production of such materials, as to any industrial process, yields wastewater effluents and has as destination, in general, water resources such as rivers and lakes. Nonetheless, government inspection cannot keep up with the number of starting companies, resulting in impunity due to lack of inspection. In the present work, the first of the kind, some chemical-physics aspects of wastewater effluents samples generated from grout industries were analyzed. The study shows that the pH of these samples lie outside the established limit by the national laws. The extremely alkaline pH and high conductivity of these effluents may cause severe damage to the aquatic environment in which they are disposed.

  4. Heterogeneity of the environmental regulation of industrial wastewater: European wineries.

    Science.gov (United States)

    Román-Sánchez, Isabel M; Aznar-Sánchez, José A; Belmonte-Ureña, Luis J

    2015-01-01

    The European legislation of the pollution of industrial wastewater shows a high degree of heterogeneity. This fact implies that there is a market failure with relevant consequences. Within the European Union, each Member State performs a specific transposition of the Water Framework Directive 2000/60. The member states introduce different sanitation fees to correct water pollution. In this paper, the case of the European wine industry is analyzed. It studies the sanitation fees of the five major wine producing countries: France, Italy, Spain, Germany and Portugal. Results show significant differences among the wastewater fees and the study reveals how such heterogeneity leads to relevant market distortions. The research concludes that more homogeneous environmental regulation would promote more sustainable wine production processes with more efficient water management and purification systems, as well as the introduction of cutting edge technologies.

  5. Microplastics in a freshwater environment receiving treated wastewater effluent.

    Science.gov (United States)

    Lasee, Steven; Mauricio, Jessica; Thompson, William A; Karnjanapiboonwong, Adcharee; Kasumba, John; Subbiah, Seenivasan; Morse, Audra N; Anderson, Todd A

    2017-05-01

    Small plastic fragments (microplastics or solid particles treated wastewater effluent in Lubbock, Texas. These lakes also serve as drainage during storm events. Water samples from drainage playa wetlands within the city were also collected. Our interest was in determining the presence or absence of microplastics in a freshwater environment as well as the source apportionment between personal care products (via wastewater) and discarded plastics (via runoff). Results showed that average concentrations of microplastics in samples collected from lakes ranged from 0.79 ± 0.88 mg/L to 1.56 ± 1.64 mg/L for the 53-105 μm size fraction and from 0.31 ± 0.72 mg/L to 1.25 ± 1.98 mg/L for the 106-179 μm size fraction. For samples collected from playa wetlands, average microplastic concentrations ranged from 0.64 ± 0.92 mg/L to 5.51 ± 9.09 mg/L for the 53-105 μm size fraction and from nondetectable (ND) to 1.79 ± 3.04 mg/L for the 106-179 μm size fraction. Our results (based on comparison of microplastic masses) suggest that urban runoff also contributes microplastics to surface water in addition to the treated wastewater effluent (in this particular case). The present findings may assist in adopting additional monitoring efforts and provide information on the potential contribution of secondary microplastic input into aquatic environments. Integr Environ Assess Manag 2017;13:528-532. © 2017 SETAC. © 2017 SETAC.

  6. One-year Surveillance of Human Enteric Viruses in Raw and Treated Wastewaters, Downstream River Waters, and Drinking Waters.

    Science.gov (United States)

    Iaconelli, M; Muscillo, M; Della Libera, S; Fratini, M; Meucci, L; De Ceglia, M; Giacosa, D; La Rosa, G

    2017-03-01

    Human enteric viruses are a major cause of waterborne diseases, and can be transmitted by contaminated water of all kinds, including drinking and recreational water. The objectives of the present study were to assess the occurrence of enteric viruses (enterovirus, norovirus, adenovirus, hepatitis A and E virus) in raw and treated wastewaters, in rivers receiving wastewater discharges, and in drinking waters. Wastewater treatment plants' (WWTP) pathogen removal efficiencies by adenovirus quantitative real-time PCR and the presence of infectious enterovirus, by cell culture assays, in treated wastewaters and in surface waters were also evaluated. A total of 90 water samples were collected: raw and treated wastewaters (treated effluents and ultrafiltered water reused for industrial purposes), water from two rivers receiving treated discharges, and drinking water. Nested PCR assays were used for the identification of viral DNA/RNA, followed by direct amplicon sequencing. All raw sewage samples (21/21), 61.9 % of treated wastewater samples (13/21), and 25 % of ultrafiltered water samples (3/12) were contaminated with at least one viral family. Multiple virus families and genera were frequently detected. Mean positive PCRs per sample decreased significantly from raw to treated sewage and to ultrafiltered waters. Moreover, quantitative adenovirus data showed a reduction in excess of 99 % in viral genome copies following wastewater treatment. In surface waters, 78.6 % (22/28) of samples tested positive for one or more viruses by molecular methods, but enterovirus-specific infectivity assays did not reveal infectious particles in these samples. All drinking water samples tested negative for all viruses, demonstrating the effectiveness of treatment in removing viral pathogens from drinking water. Integrated strategies to manage water from all sources are crucial to ensure water quality.

  7. Reference Guide for Industrial Wastewater Treatment.

    Science.gov (United States)

    1985-09-01

    recovery process, such as ion exchange, evaporation, and electrolysis . The value of copper metal frequent- ly makes recovering it more attractive...hydrogen ions or salt brine to replace sodium, and by passing a strong base through anion resins to replace hydroxide ions. Typically, ion...addressed. Cyanide can be treated using alkaline chlorination, electrolysis , or ozonation. (2) Reduction of valence is most commonly done on chrome

  8. Evaluation of low cost cathode materials for treatment of industrial and food processing wastewater using microbial electrolysis cells

    KAUST Repository

    Tenca, Alberto

    2013-02-01

    Microbial electrolysis cells (MECs) can be used to treat wastewater and produce hydrogen gas, but low cost cathode catalysts are needed to make this approach economical. Molybdenum disulfide (MoS2) and stainless steel (SS) were evaluated as alternative cathode catalysts to platinum (Pt) in terms of treatment efficiency and energy recovery using actual wastewaters. Two different types of wastewaters were examined, a methanol-rich industrial (IN) wastewater and a food processing (FP) wastewater. The use of the MoS2 catalyst generally resulted in better performance than the SS cathodes for both wastewaters, although the use of the Pt catalyst provided the best performance in terms of biogas production, current density, and TCOD removal. Overall, the wastewater composition was more of a factor than catalyst type for accomplishing overall treatment. The IN wastewater had higher biogas production rates (0.8-1.8 m3/m3-d), and COD removal rates (1.8-2.8 kg-COD/m3-d) than the FP wastewater. The overall energy recoveries were positive for the IN wastewater (3.1-3.8 kWh/kg-COD removed), while the FP wastewater required a net energy input of -0.7 - 1.2 kWh/kg-COD using MoS 2 or Pt cathodes, and -3.1 kWh/kg-COD with SS. These results suggest that MoS2 is the most suitable alternative to Pt as a cathode catalyst for wastewater treatment using MECs, but that net energy recovery will be highly dependent on the specific wastewater. © 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

  9. Thermophilic biological nitrogen removal in industrial wastewater treatment.

    OpenAIRE

    Lopez-Vazquez, CM; Kubare, M; Saroj, DP; Chikamba, C; Schwarz, J; Daims, H; Brdjanovic, D

    2013-01-01

    Nitrification is an integral part of biological nitrogen removal processes and usually the limiting step in wastewater treatment systems. Since nitrification is often considered not feasible at temperatures higher than 40 °C, warm industrial effluents (with operating temperatures higher than 40 °C) need to be cooled down prior to biological treatment, which increases the energy and operating costs of the plants for cooling purposes. This study describes the occurrence of thermophilic biologic...

  10. Application of Genetic Engineering for Chromium Removal from Industrial Wastewater

    OpenAIRE

    N. K. Srivastava; M. K. Jha; I. D. Mall; Davinder Singh

    2010-01-01

    The treatment of the industrial wastewater can be particularly difficult in the presence of toxic compounds. Excessive concentration of Chromium in soluble form is toxic to a wide variety of living organisms. Biological removal of heavy metals using natural and genetically engineered microorganisms has aroused great interest because of its lower impact on the environment. Ralston metallidurans, formerly known as Alcaligenes eutrophus is a LProteobacterium colonizing indus...

  11. Quality assessment of treated wastewater to be reused in agriculture

    Directory of Open Access Journals (Sweden)

    M.H. Rahimi

    2018-04-01

    Full Text Available In this study, the quality of a treated wastewater for agricultural and irrigation purposes was investigated. 39 quality parameters were investigated at the entrance of an effluent channel to the destination plain in monthly time intervals during a year. The aim of this study was drawing an analogy between analyses results and the latest standards in the world (nationwide and internationally, the agricultural and irrigation usage indexes and the Wilcox diagram. The results showed that some parameters such as turbidity, total suspended solids, electrical conductivity, sodium, detergents, total coliform and focal coliform, ammonium, residual sodium carbonate, the Kelly’s Ratio and the Wilcox diagram were exceeding the permissible limit and are not suitable for agriculture and irrigation. It was found that the aquifers in the study area were polluted by natural salinity and geogenic source. As a result, application of the treated wastewater from Qom for agriculture and irrigation purposes needs to be revised and monitored. An action plan is also needed to manage a huge source of water and to avoid further environmental and health risks.

  12. Molybdenum sulphides on carbon supports as electrocatalysts for hydrogen evolution in acidic industrial wastewater

    International Nuclear Information System (INIS)

    Kokko, M.; Bayerköhler, F.; Erben, J.; Zengerle, R.; Kurz, Ph.; Kerzenmacher, S.

    2017-01-01

    Highlights: • MoS x is an efficient and durable catalyst for H 2 evolution in acidic wastewater. • MoS x outperformed Pt as H 2 -catalyst in long term in acidic wastewater. • Improved activity over time was likely due to changes in MoS x structure. - Abstract: Microbial electrolysis cells (MECs) are an attractive future alternative technology to generate renewable hydrogen and simultaneously treat wastewaters. The thermodynamics of hydrogen evolution in MECs can be greatly improved by operating the cathode at acidic pH in combination with a neutral pH microbial anode. This can easily be achieved with acidic industrial wastewaters that have to be neutralised before discharge. For the hydrogen evolution reaction (HER) in acidic wastewater, efficient and inexpensive catalysts are required that are compatible with the often complex chemical composition of wastewaters. In this study, molybdenum sulphides (MoS x ) on different carbon supports were successfully used for hydrogen evolution in different acidic media. At first, the cathodes were screened by linear sweep voltammetry in sulphuric acid (pH 0) or phosphate buffer (pH 2.2). After this, the overpotentials for H 2 production of the best cathodes and their long term performances (⩾1 week) were determined in acidic industrial wastewater (pH 2.4) obtained from a plant mainly producing cellulose acetate. For the most promising MoS x cathodes, the overpotentials for HER (at 3 mA cm −2 ) were only ∼40 mV higher than for a platinum electrode. Most importantly, the catalytic efficiency of the MoS x electrodes improved in the wastewater over time (7–17 days), while Pt electrodes were found to be slowly deactivated. Thus, MoS x emerges as an affordable, efficient and especially durable electrocatalyst for HER in real acidic wastewaters and this could be an important contribution to take energy production from wastewaters in the form of hydrogen towards practical applications.

  13. Treatment and Reuse of Wastewaters Discharged by Petroleum Industries (HMD/Algeria)

    Energy Technology Data Exchange (ETDEWEB)

    Sellami, MH, E-mail: sellami2000dz@gmail.com [Process Engineering Department, Laboratory of Process Engineering, Ouargla University (Algeria); Loudiyi, K [Renewable Energies Laboratory (REL) Al Akhawayne University, Ifrane (Morocco); Boubaker, MC; Habbaz, H [Process Engineering Department, Laboratory of Process Engineering, Ouargla University (Algeria)

    2015-12-23

    Industrial wastewaters discharged by petroleum industries contains: oil, heavy metals and chemicals used in the process of oil separation and treatment. These waters are a source of soil, water and air pollution, and lead a mortal danger to the ecosystem. Our aim in this work has an aspect that can contribute to the collective effort to address the enormous amount of water purges storage bins and reuse them to avoid any environmental damage. This was achieved by chemical treating of these wastewaters discharged from three different locations of Hassi Messaoud (HMD) petroleum field by flocculation with (C-5563) followed by coagulation with (C-2061) using two different acids as sequestering namely: Ascorbic and Citric acid. After experiments, the results showed that the wastewater can be treated without sequestering by adding 40 ppm of activated silicates. The best result was obtained by addition of 160 ppm of Ascorbic acid as sequestering agent and 20 ppm of activated silicates; resulting in removal of 92.81 % of suspended matter and 95.53 % of turbidity. Finally we concluded that this wastewater was satisfactorily treated and we recommend either inject it for enhanced oil recovery in industrial closest field (North field) to maintain the reservoir pressure and the improved rate recovery of oil reserves or reuse it in garden irrigation. In order to see the impact of the treated water on plants, irrigation tests have conducted on two types of plants (date palm and shaft apocalyptic) for one year. The tests showed that the thick layer of 5 cm and 0.08mm of particles diameter of dune sand removes most of remaining oil. The sand layer that fills the basin surrounding the shaft is removed and replaced every 06 months. So, Dune sand plays the role of natural filter. The garden plants appear and grow normally.

  14. Treatment and Reuse of Wastewaters Discharged by Petroleum Industries (HMD/Algeria)

    International Nuclear Information System (INIS)

    Sellami, MH; Loudiyi, K; Boubaker, MC; Habbaz, H

    2015-01-01

    Industrial wastewaters discharged by petroleum industries contains: oil, heavy metals and chemicals used in the process of oil separation and treatment. These waters are a source of soil, water and air pollution, and lead a mortal danger to the ecosystem. Our aim in this work has an aspect that can contribute to the collective effort to address the enormous amount of water purges storage bins and reuse them to avoid any environmental damage. This was achieved by chemical treating of these wastewaters discharged from three different locations of Hassi Messaoud (HMD) petroleum field by flocculation with (C-5563) followed by coagulation with (C-2061) using two different acids as sequestering namely: Ascorbic and Citric acid. After experiments, the results showed that the wastewater can be treated without sequestering by adding 40 ppm of activated silicates. The best result was obtained by addition of 160 ppm of Ascorbic acid as sequestering agent and 20 ppm of activated silicates; resulting in removal of 92.81 % of suspended matter and 95.53 % of turbidity. Finally we concluded that this wastewater was satisfactorily treated and we recommend either inject it for enhanced oil recovery in industrial closest field (North field) to maintain the reservoir pressure and the improved rate recovery of oil reserves or reuse it in garden irrigation. In order to see the impact of the treated water on plants, irrigation tests have conducted on two types of plants (date palm and shaft apocalyptic) for one year. The tests showed that the thick layer of 5 cm and 0.08mm of particles diameter of dune sand removes most of remaining oil. The sand layer that fills the basin surrounding the shaft is removed and replaced every 06 months. So, Dune sand plays the role of natural filter. The garden plants appear and grow normally

  15. Genotoxicity of sludges, wastewater and effluents from three different industries

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamurthi, K.; Saravana Devi, S.; Kumar, Koel; Dutta, Dipanwita; Muhil Vannan, S.; Subin, T.S.; Yadav, R.R.; Chakrabarti, T. [National Environmental Engineering Research Institute (NEERI), Environmental Biotechnology Division, Nagpur (India); Hengstler, J.G.; Hermes, Matthias [Leibniz Research Centre for Working Environment and Human Factors at the University of Dortmund (IfADo), Dortmund (Germany)

    2008-12-15

    Many surface waters in Europe, Asia and South America have been reported to be contaminated with genotoxic substances. Therefore, it is important to establish strategies for identification of the most critical sources. In this study, we used a battery of four genotoxicity assays namely chromosomal aberration, DNA strand break, DNA laddering and P53 accumulation tests in mononuclear blood cells. Before cleaning of wastewater high levels of genotoxic contamination could be observed. For instance, we observed an increase in chromosomal aberrations from 2.6{+-}1.1 (aberrant cells in %; control), to 33.6{+-}6.6 in a petrochemical plant, 29.4{+-}3.3 in a petroleum refinery and 14.4{+-}1.8 in a coke plant of steel industry. A good correlation between the four assays was found. The most sensitive and reproducible results were obtained with the chromosomal aberration assay. Interestingly, clear differences in the efficiency of wastewater cleaning in three different treatment plants were observed. The first and second treatment plants in petrochemical industry and coke plant of steel industry completely eliminated genotoxicity of the wastewater. However, the third plant in petroleum refinery could achieve a reduction in genotoxicity but significant genotoxic contaminations were still present. In conclusion, our battery of genotoxicity tests allows the identification of critical sources contributing to contamination of surface waters. (orig.)

  16. Pollutant removal-oriented yeast biomass production from high-organic-strength industrial wastewater: A review

    International Nuclear Information System (INIS)

    Yang, Min; Zheng, Shaokui

    2014-01-01

    Microbial single-cell-protein (SCP) production from high-organic-strength industrial wastewaters is considered an attractive method for both wastewater purification and resource utilization. In the last two decades, pollutant removal-oriented yeast SCP production processes, i.e., yeast treatment processes, have attracted a great deal of attention from a variety of research groups worldwide. Different from conventional SCP production processes, yeast treatment processes are characterized by higher pollutant removal rates, lower production costs, highly adaptive yeast isolates from nature, no excess nutrient supplements, and are performed under non-sterile conditions. Furthermore, yeast treatment processes are similar to bacteria-dominated conventional activated sludge processes, which offer more choices for yeast SCP production and industrial wastewater treatment. This review discusses why highly adaptive yeast species isolated from nature are used in the yeast treatment process rather than commercial SCP producers. It also describes the application of yeast treatment processes for treating high-carboxyhydrate, oil-rich and high-salinity industrial wastewater, focusing primarily on high-strength biodegradable organic substances, which usually account for the major fraction of biochemical oxygen demand. Also discussed is the biodegradation of xenobiotics, such as color (including dye and pigment) and toxic substances (including phenols, chlorophenols, polycyclic aromatic hydrocarbons, etc.), present in industrial wastewater. Based on molecular information of yeast community structures and their regulation in yeast treatment systems, we also discuss how to maintain efficient yeast species in yeast biomass and how to control bacterial and mold proliferation in yeast treatment systems. - Highlights: • Pollutant removal-oriented yeast SCP production processes offer more choices. • Highly adaptive yeast isolates replace commercial SCP producers. • Yeasts degrade

  17. Study of soil bacterial and crop quality irrigated with treated municipal wastewater

    OpenAIRE

    Afsaneh Alinezhadian; Ahmad Karimi; Jahangard Mohammadi; Farzaneh Nikookhah; Mathias Niuman. Anderson

    2014-01-01

    Background and Objectives: In arid and semi-arid regions, wastewater reuse has become an important element in agriculture. However, irrigation with this resource can be either beneficial or harmful, depending on the wastewater characteristics. The aim of this research was to investigate the soil bacterial and crops quality irrigated with treated wastewater. Material and Methods: This research was conducted on a maize field near the wastewater treatment plant in Shahr-e-kord in summer,2011....

  18. Fenton-biological treatment processes for the removal of some pharmaceuticals from industrial wastewater.

    Science.gov (United States)

    Badawy, Mohamed I; Wahaab, Rifaat A; El-Kalliny, A S

    2009-08-15

    A treatability study of pharmaceutical wastewater from El-Nasr Pharmaceutical and Chemical Company, South-East of Cairo, was carried out. The company discharges both industrial (6000 m(3)/d) and municipal wastewater (128 m(3)/d) into a nearby evaporation pond without any treatment. The generated raw wastewater is characterized by high values of COD (4100-13,023), TSS (20-330 mg/L), and oil grease (17.4-600 mg/L). In addition, the presence of refractory compounds decreases BOD/COD ratio (0.25-0.30). Analysis of raw wastewater confirmed that pre-treatment is required prior to discharge into public sewers to comply with the Egyptian Environmental laws and regulations. The obtained results indicated that the refractory compounds and their by-products cannot be readily removed by biological treatment and always remain in the treated effluent or adsorbed on the sludge flocs. The application of Fenton oxidation process as a pre-treatment improved the removal of pharmaceuticals from wastewater and appears to be an affective solution to achieve compliance with the law legislation with respect to discharge in a determined receptor medium.

  19. Sludge accumulation in polishing ponds treating anaerobically digested wastewater.

    Science.gov (United States)

    Cavalcanti, P; van Haandel, A; Lettinga, G

    2002-01-01

    When ponds are used for wastewater treatment, settleable solids will form a steadily growing bottom sludge layer, which reduces their effective volume. Eventually this sludge must be removed to ensure that the pond maintains the required retention time to keep performing properly. The settleable solids may either be present in the influent or they are formed during the treatment as a result of algal flocculation. An experimental investigation was carried out to evaluate bottom sludge accumulation in a polishing pond used for treatment of UASB effluent. The mass and composition of the bottom sludge formed in a polishing pond was evaluated after the pilot scale pond had been in operation for 1 year and about 60 m3 of digested wastewater had been treated per m3 of pond. The bottom sludge mass represented a solids accumulation of 70 g per m3 of digested wastewater. About half of these solids were the result of settling of influent solids in the first part of the pond, while the other half was attributable to settling of algae, formed in the pond. It is concluded that the bottom sludge growth in a polishing pond is so low, that desludging during the useful life span of the pond will most likely not be necessary. This leads to the important conclusion that excess sludge discharge from UASB reactors (a major factor in operational costs) may be omitted, if a polishing pond is used for post-treatment. The bottom sludge had a high volatile solids concentration (58%) and the macronutrient fractions were also high (3.9% N and 1.1% P of the TSS mass). The bottom sludge was stable and could be dried directly without problems. The hygienic quality of the bottom sludge was very poor: about half the influent helminth eggs during one year of operation were found in the bottom sludge and the faecal coliform concentration was very high.

  20. APPLICATION OF PAN/PANI COMPOSITE MEMBRANES IN PURIFICATION OF INDUSTRIAL WASTEWATER GENERATED DURING PROCESSING OF METALS

    Directory of Open Access Journals (Sweden)

    Beata Fryczkowska

    2017-04-01

    Full Text Available The paper presents results of research on the use of composite membranes of polyacrylonitrile (PAN doped polyaniline (PANI to remove contaminations of industrial wastewater generated during the processing of metals. Wastewater obtained from industry was pre-treated with the flocculant Magnafloc®336, and then the supernatant solution was introduced into the ultrafiltration cell, AMICON (Millipore equipped in the previously prepared polymer membrane. Using spectrophotometer UV-Vis (HACH and atomic absorption spectrometry (AAS pollution indicators was marked before and after the integrated purification proces, to determine the degree of removal of selected ions from wastewater. As a result of flocculation from wastewater there have been removed phosphates (79%, chlorides (11-14%, sulfates (2-10% and iron (36-92%, cobalt (~ 80%, cadmium (~ 31% and nickel (~ 25%. However, the pressure membrane process almost completely removed zinc, copper and cadmium (~ 100%, iron (by a further 43-69% and phosphate anions, which was a little.

  1. Regulating industrial wastewater discharged to public wastewater treatment plants - A conceptual approach

    DEFF Research Database (Denmark)

    Grüttner, Henrik

    1997-01-01

    prevention and the implementation of cleaner technology by putting a stress on the industry. Further an approach for the balance between environmental and technological considerations is introduced. The need for easily understandable environmental priorities is stressed and a concept for this is presented......The paper describes some of the basic principles behind the DEPA Guidelines for discharge of industrial wastewater to public sewers set in operation in 1995 and evaluates some of the experiences with the implementation. It is described how such guidelines support the approach of pollution...

  2. Anaerobic treatment of agro-industrial wastewaters for COD removal in expanded granular sludge bed bioreactor

    Directory of Open Access Journals (Sweden)

    Abumalé Cruz-Salomón

    2017-12-01

    Full Text Available Untreated agro-industrial wastewaters are undesirable in the aquatic environment due to the presence of high organic matter contents. However, they may constitute a large potential for biogas production. The present investigation is focused on three laboratory-scale anaerobic expanded granular sludge bed (EGSB bioreactors, continuously operated for 60 d under mesophilic condition with the aim of exploring the feasibility of treating three most significant agro-industrial wastewaters in Chiapas, Mexico (i.e., cheese whey, vinasse, and coffee-processing wastewater. The EGSB bioreactors were operated with a hydraulic retention time (HRT of 6 d under stable conditions (i.e., buffer index (BI of 0.31, 0.34, and 0.03, generating a maximum chemical oxygen demand (COD removal efficiency of 91, 74, and 96% with an average methane production of 340, 245, and 300 mL/g COD∙d for cheese whey, vinasse, and coffee-processing wastewater, respectively. According to the obtained results, the EGSB bioreactors could be a sustainable alternative to simultaneously solve the environmental problems and to produce bioenergy.

  3. Process model economics of xanthan production from confectionery industry wastewaters.

    Science.gov (United States)

    Bajić, Bojana Ž; Vučurović, Damjan G; Dodić, Siniša N; Grahovac, Jovana A; Dodić, Jelena M

    2017-12-01

    In this research a process and cost model for a xanthan production facility was developed using process simulation software (SuperPro Designer ® ). This work represents a novelty in the field for two reasons. One is that xanthan gum has been produced from several wastes but never from wastewaters from confectionery industries. The other more important is that the aforementioned software, which in intended exclusively for bioprocesses, is used for generating a base case, i.e. starting point for transferring the technology to industrial scales. Previously acquired experimental knowledge about using confectionery wastewaters from five different factories as substitutes for commercially used cultivation medium have been incorporated into the process model in order to obtain an economic viability of implementing such substrates. A lower initial sugar content in the medium based on wastewater (28.41 g/L) compared to the synthetic medium (30.00 g/L) gave a lower xanthan content at the end of cultivation (23.98 and 26.27 g/L, respectively). Although this resulted in somewhat poorer economic parameters, they were still in the range of being an investment of interest. Also the possibility of utilizing a cheap resource (waste) and reducing pollution that would result from its disposal has a positive effect on the environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Long-term Effects of Different Irrigation Methods with Treated Wastewater on Soil Chemical Properties

    Directory of Open Access Journals (Sweden)

    P. Najafi

    2016-02-01

    Full Text Available Introduction: Reuse of wastewater for agricultural irrigation is increasing due to an increased demand for water resources in different parts of the world. Almost 70% of deviated water from rivers and pumped groundwater is used for agriculture. If wastewater is used for irrigation in agriculture, then the amount of discharged water from natural sources will be decreased and the flow of wastewater to the environment and its ensuing pollution will be prevented. Using wastewater in applications such as irrigation of agricultural lands has caused an increase of some exchangeable ions, salts and suspended solids (organic and mineral in the soil and has significantly affected physical, chemical and biological features. Therefore, paying attention to the soil health is important during use of wastewater when it is the source of irrigation water. In such cases, there will be some worries about pollution of harvested products, contact of farm workers with pathogenes and environmental issues in the farm. In these conditions, attention to irrigation methods along with consideration of environmental protection standards is important. Materials and Methods: In this study, the effects of treated wastewater (TW irrigation were tested on some chemical properties of soil for three years under five different irrigation treatments. The treatments were as follows: surface furrow irrigation (FI, surface drip irrigation (SDI, subsurface drip irrigation in 30 cm depth (SDI30, subsurface drip irrigation in 60 cm depth (SDI60 and bubbler irrigation (BI. At the end of the experiment, soil samples were collected from a depth of 0-30, 30-60 and 60-90 cm in order to measure the electrical conductivity (EC, pH, sodium adsorption ratio (SAR, organic matter (OM and calcium carbonate equivalent (CaCO3. Results and Discussion: According to the results of soil analysis, the soil became more saline than the beginning by applying the treatments. Generally, in two plots of urban and

  5. A Comprehensive Study on the Application of Reverse Osmosis (RO Technology for the Petroleum Industry Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Shahryar Jafarinejad

    2017-10-01

    Full Text Available Large quantities of oily wastewaters can be generated from the activities and processes in the petroleum industry which draining of these effluents not only pollutes the environment but also reduces the yield of oil and water. Therefore, development of treatment processes for petroleum industry wastewaters is vital in order to prevent serious environmental damage and provide a source of water for beneficial use. Reverse osmosis (RO can be the most common membrane process used for desalination from oily wastewater and can produce water suitable for reuse at the petroleum industry. In this study, the application of RO technology for the petroleum industry wastewater treatment in different laboratory, pilot, field, and industrial scales have been reviewed. In addition, membrane fouling control, performance efficiency, treatment system configurations, pretreatment methods, quality of treated water, and economic issues have been investigated. With mixtures as complex as petroleum industry wastewaters, membrane fouling becomes a significant hurdle to implement the RO-based purification system. Operating the system within the critical flux range or adding chemicals, and/or pretreatment can usually control membrane fouling. Salt rejection of RO membranes can be 99% or higher.

  6. Identification of industrial wastewater by clustering wastewater treatment plant influent ultraviolet visible spectra.

    Science.gov (United States)

    Dürrenmatt, David J; Gujer, Willi

    2011-01-01

    A procedure is proposed which allows the detection of industrial discharge events at the inlet of a wastewater treatment plant without the need for measurements performed at the industry, for special equipment and for exact knowledge of the industrial sewage. By performing UV/Vis measurements at the inlet of a plant and analyzing them with a two-staged clustering method consisting of the self-organizing map algorithm and the Ward clustering method, typical sewage clusters can be found. In an experiment performed at a mid-sized Swiss plant, one cluster of a cluster model with five clusters could be attributed to an industrial laundry. Out of 95 laundry discharging events measured in a validation period, 93 were correctly detected by the proposed algorithm, two were false positives and five were false negatives.

  7. Photo-Fenton and Fenton Oxidation of Recalcitrant Industrial Wastewater Using Nanoscale Zero-Valent Iron

    Directory of Open Access Journals (Sweden)

    Henrik Hansson

    2012-01-01

    Full Text Available There is a need for the development of on-site wastewater treatment technologies suitable for “dry-process industries,” such as the wood-floor sector. Due to the nature of their activities, these industries generate lower volumes of highly polluted wastewaters after cleaning activities. Advanced oxidation processes such as Fenton and photo-Fenton, are potentially feasible options for treatment of these wastewaters. One of the disadvantages of the Fenton process is the formation of large amounts of ferrous iron sludge, a constraint that might be overcome with the use of nanoscale zero-valent iron (nZVI powder. Wastewater from a wood-floor industry with initial COD of 4956 mg/L and TOC of 2730 mg/L was treated with dark-Fenton (nZVI/H2O2 and photo-Fenton (nZVI/H2O2/UV applying a 2-level full-factorial experimental design. The highest removal of COD and TOC (80% and 60%, resp. was achieved using photo-Fenton. The supply of the reactants in more than one dose during the reaction time had significant and positive effects on the treatment efficiency. According to the results, Fenton and mostly photo-Fenton are promising treatment options for these highly recalcitrant wastewaters. Future investigations should focus on optimizing treatment processes and assessing toxic effects that residual pollutants and the nZVI might have. The feasibility of combining advanced oxidation processes with biological treatment is also recommended.

  8. Recycling of treated domestic effluent from an on-site wastewater treatment system for hydroponics.

    Science.gov (United States)

    Oyama, N; Nair, J; Ho, G E

    2005-01-01

    An alternative method to conserve water and produce crops in arid regions is through hydroponics. Application of treated wastewater for hydroponics will help in stripping off nutrients from wastewater, maximising reuse through reduced evaporation losses, increasing control on quality of water and reducing risk of pathogen contamination. This study focuses on the efficiency of treated wastewater from an on-site aerobic wastewater treatment unit. The experiment aimed to investigate 1) nutrient reduction 2) microbial reduction and 3) growth rate of plants fed on wastewater compared to a commercial hydroponics medium. The study revealed that the chemical and microbial quality of wastewater after hydroponics was safe and satisfactory for irrigation and plant growth rate in wastewater hydroponics was similar to those grown in a commercial medium.

  9. Whole effluent assessment of industrial wastewater for determination of BAT compliance. Part 2: metal surface treatment industry.

    Science.gov (United States)

    Gartiser, Stefan; Hafner, Christoph; Hercher, Christoph; Kronenberger-Schäfer, Kerstin; Paschke, Albrecht

    2010-06-01

    Toxicity testing has become a suitable tool for wastewater evaluation included in several reference documents on best available techniques of the Integrated Pollution Prevention and Control (IPPC) Directive. The IPPC Directive requires that for direct dischargers as well as for indirect dischargers, the same best available techniques should be applied. Within the study, the whole effluent assessment approach of OSPAR has been applied for determining persistent toxicity of indirectly discharged wastewater from the metal surface treatment industry. Twenty wastewater samples from the printed circuit board and electroplating industries which indirectly discharged their wastewater to municipal wastewater treatment plants (WWTP) have been considered in the study. In all factories, the wastewater partial flows were separated in collecting tanks and physicochemically treated in-house. For assessing the behaviour of the wastewater samples in WWTPs, all samples were biologically pretreated for 7 days in the Zahn-Wellens test before ecotoxicity testing. Thus, persistent toxicity could be discriminated from non-persistent toxicity caused, e.g. by ammonium or readily biodegradable compounds. The fish egg test with Danio rerio, the Daphnia magna acute toxicity test, the algae test with Desmodesmus subspicatus, the Vibrio fischeri assay and the plant growth test with Lemna minor have been applied. All tests have been carried out according to well-established DIN or ISO standards and the lowest ineffective dilution (LID) concept. Additionally, genotoxicity was tested in the umu assay. The potential bioaccumulating substances (PBS) were determined by solid-phase micro-extraction and referred to the reference compound 2,3-dimethylnaphthalene. The chemical oxygen demand (COD) and total organic carbon (TOC) values of the effluents were in the range of 30-2,850 mg L(-1) (COD) and 2-614 mg L(-1) (TOC). With respect to the metal concentrations, all samples were not heavily polluted. The

  10. Application of the removal of pollutants from textile industry wastewater in constructed wetlands using fuzzy logic.

    Science.gov (United States)

    Dogdu, Gamze; Yalcuk, Arda; Postalcioglu, Seda

    2017-02-01

    There are more than a hundred textile industries in Turkey that discharge large quantities of dye-rich wastewater, resulting in water pollution. Such effluents must be treated to meet discharge limits imposed by the Water Framework Directive in Turkey. Industrial treatment facilities must be required to monitor operations, keep them cost-effective, prevent operational faults, discharge-limit infringements, and water pollution. This paper proposes the treatment of actual textile wastewater by vertical flow constructed wetland (VFCW) systems operation and monitoring effluent wastewater quality using fuzzy logic with a graphical user interface. The treatment performance of VFCW is investigated in terms of chemical oxygen demand and ammonium nitrogen (NH4-N) content, color, and pH parameters during a 75-day period of operation. A computer program was developed with a fuzzy logic system (a decision- making tool) to graphically present (via a status analysis chart) the quality of treated textile effluent in relation to the Turkish Water Pollution Control Regulation. Fuzzy logic is used in the evaluation of data obtained from the VFCW systems and for notification of critical states exceeding the discharge limits. This creates a warning chart that reports any errors encountered in a reactor during the collection of any sample to the concerned party.

  11. Use of hydroponics culture to assess nutrient supply by treated wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Adrover, M.; Moya, G.; Vadell, J.

    2009-07-01

    The use of treated wastewater for irrigation is increasing, especially in those areas where water resources are limited. Treated wastewaters contain nutrients that are useful for plant growth and help to reduce fertilizers needs. Nutrient content of these waters depends on the treatment system. (Author)

  12. Treatment of organic pollution in industrial saline wastewater: a literature review.

    Science.gov (United States)

    Lefebvre, Olivier; Moletta, René

    2006-12-01

    Many industrial sectors are likely to generate highly saline wastewater: these include the agro-food, petroleum and leather industries. The discharge of such wastewater containing at the same time high salinity and high organic content without prior treatment is known to adversely affect the aquatic life, water potability and agriculture. Thus, legislation is becoming more stringent and the treatment of saline wastewater, both for organic matter and salt removal, is nowadays compulsory in many countries. Saline effluents are conventionally treated through physico-chemical means, as biological treatment is strongly inhibited by salts (mainly NaCl). However, the costs of physico-chemical treatments being particularly high, alternative systems for the treatment of organic matter are nowadays increasingly the focus of research. Most of such systems involve anaerobic or aerobic biological treatment. Even though biological treatment of carbonaceous, nitrogenous and phosphorous pollution has proved to be feasible at high salt concentrations, the performance obtained depends on a proper adaptation of the biomass or the use of halophilic organisms. Another major limit is related to the turbidity problems inherent in saline effluents. For this reason, the major need for research in the future will be the combination of physico-chemical/biological treatment of saline industrial effluents, with regard to the global treatment chain, in order to meet the regulations.

  13. Biotransformation of phosphogypsum in wastewaters from the dairy industry.

    Science.gov (United States)

    Wolicka, Dorota

    2008-09-01

    The biotransformation of phosphogypsum by stationary cultures of sulphate reducing bacteria (SRB) in dairy wastewaters (sterile and non-sterile) enriched in phosphogypsum, was studied SRB were isolated from soil contaminated with petroleum-derived products and from wastewaters from the petroleum-refining industry, taking into account that these environments are characteristic for the bacteria of the studied group. The biotransformation products formed were investigated using biological and mineralogical methods. Sulphides in the cultures were determined using the iodometric method, sulphates with the hot barium method, COD by the dichromate method. Determinations involving post-culture sediments and fluids, Ca, S, Sr and P were made using the following analytical procedures: IPC emission spectrometry with induced excitation in the medium and X-ray. Analysis of post-culture sediments was made using a DRON-2 X-ray diffractometer. Eleven communities of microorganisms with varying degrees of effectiveness were obtained, biodegrading 58% to 98% of the organic contaminants in non-sterile wastewater, with simultaneous biotransformation of about 2.5 g phosphogypsum/L.

  14. The assessment of treated wastewater quality and the effects of mid-term irrigation on soil physical and chemical properties (case study: Bandargaz-treated wastewater)

    Science.gov (United States)

    Kaboosi, Kami

    2017-09-01

    This study was conducted to investigate the characteristics of inflow and outflow wastewater of the Bandargaz wastewater treatment plant on the basis of the data collection of operation period and the samples taken during the study. Also the effects of mid-term use of the wastewater for irrigation (from 2005 to 2013) on soil physical and chemical characteristics were studied. For this purpose, 4 samples were taken from the inflow and outflow wastewater and 25 quality parameters were measured. Also, the four soil samples from a depth of 0-30 cm of two rice field irrigated with wastewater in the beginning and middle of the planting season and two samples from one adjacent rice field irrigated with fresh water were collected and their chemical and physical characteristics were determined. Average of electrical conductivity, total dissolved solids, sodium adsorption ratio, chemical oxygen demand and 5 days biochemical oxygen demand in treated wastewater were 1.35 dS/m, 707 ppm, 0.93, 80 ppm and 40 ppm, respectively. Results showed that although some restrictions exist about chlorine and bicarbonate, the treated wastewater is suitable for irrigation based on national and international standards and criteria. In comparison with fresh water, the mid-term use of wastewater caused a little increase of soil salinity. However, it did not lead to increase of soil salinity beyond rice salinity threshold. Also, there were no restrictions on soil in the aspect of salinity and sodium hazard on the basis of many irrigated soil classifications. In comparison with fresh water, the mid-term use of wastewater caused the increase of total N, absorbable P and absorbable K in soil due to high concentration of those elements in treated wastewater.

  15. Generation and energy utilization of methane form industrial wastewater

    International Nuclear Information System (INIS)

    Lebek, M.

    2009-01-01

    At the production site of a natural ingredients manufacturer for the food industry was necessary the adjustment of the WWTP to the enlargement of the production and its complement with a pre-treatment. The core of the treatment plan tis an UASB (Upflow Anaerobic Sludge Blanket) reactor where the wastewater is removed under anaerobic conditions. The main advantages of this treatment ar the operation stability and the high methane production. The biogas generated is cleaned before it is used during the production process as an energy resource. (Author)

  16. Regulating specific organic substances and heavy metals in industrial wastewater discharged to municipal wastewater treatment plants

    DEFF Research Database (Denmark)

    Grüttner, Henrik; Munk, L.; Pedersen, F.

    1994-01-01

    Due to the extension of wastewater treatment plants to nutrient removal and the development towards reuse of sludge m agriculture, new guidelines for regulating industrial discharges m Denmark were needed. The paper describes how a concept for regulating the discharge of specific organic substances...... for sludge intended for use in agriculture, and the quality criteria for the aquatic environment. Proposals for general guidelines have been calculated using a simple mass balance model combined with water quality criteria and the Danish limit values for use of sludge in agriculture....

  17. Arsenite oxidizing multiple metal resistant bacteria isolated from industrial effluent: their potential use in wastewater treatment.

    Science.gov (United States)

    Naureen, Ayesha; Rehman, Abdul

    2016-08-01

    Arsenite oxidizing bacteria, isolated from industrial wastewater, showed high resistance against arsenite (40 mM) and other heavy metals (10 mM Pb; 8 mM Cd; 6 mM Cr; 10 mM Cu and 26.6 mM As(5+)). Bacterial isolates were characterized, on the basis of morphological, biochemical and 16S rRNA ribotyping, as Bacillus cereus (1.1S) and Acinetobacter junii (1.3S). The optimum temperature and pH for the growth of both strains were found to be 37 °C and 7. Both the strains showed maximum growth after 24 h of incubation. The predominant form of arsenite oxidase was extracellular in B. cereus while in A. junii both types of activities, intracellular and extracellular, were found. The extracellular aresenite oxidase activity was found to be 730 and 750 µM/m for B. cereus and A. junii, respectively. The arsenite oxidase from both bacterial strains showed maximum activity at 37 °C, pH 7 and enhanced in the presence of Zn(2+). The presence of two protein bands with molecular weight of approximately 70 and 14 kDa in the presence of arsenic points out a possible role in arsenite oxidation. Arsenite oxidation potential of B. cereus and A. junii was determined up to 92 and 88 % in industrial wastewater after 6 days of incubation. The bacterial treated wastewater improved the growth of Vigna radiata as compared to the untreated wastewater. It indicates that these bacterial strains may find some potential applications in wastewater treatment systems to transform toxic arsenite into less toxic form, arsenate.

  18. Case study: centralized wastewater treatment plant at Rawang Integrated Industrial Park

    International Nuclear Information System (INIS)

    Ting Teo Ming; Khomsaton Abu Bakar; Zulkafli Ghazali; Khairul Zaman Mohd Dahlan

    2006-01-01

    Survey has been conducted at Rawang Integrated Industrial Park (RIIP) to investigate the possibility of setting up centralized industrial wastewater treatment plant. Rawang integrated industrial park is selected based on suggestion from department of environment. RIIP consists of about 150 industries with various type of activities operated in the area. Only 9 out of estimated 150 industries have individual wastewater treatment plant. The business activities of the 9 industries include food processing, textile, welding rods manufacturing, steel galvanizing and battery manufacturing. Wastewater generated by the industries are characterized by high oil and grease, cod, bod, organic matter, metal hydroxide and acidic. Besides that most of industries do the monitoring only once a month. This paper will also discuss the advantages of setting up of centralized industrial wastewater treatment plant to the government authorities, industries, people and environment. (Author)

  19. Masterplan Sistem Pengelolaan Air Limbah Industri Di Kawasan Industri Bsb City, Mijen-semarang

    OpenAIRE

    Triyani, Ruli; Oktiawan, Wiharyanto; Dwi Nugraha, Winardi

    2013-01-01

    Industrial Park BSB City, Mijen-Semarang has concept as green technology industrial park. There's 11 industry producting wastewater in existing area at this time. The industrial wastewater flow to drainage without any treatment which make odours at industrial park area. PT Karyadeka Alam Lestari as developer industrial would be like to build wastewater treatment plant which treat all wastewater industries therefore it needs Masterplan Management System Wastewater Industry At Industrial Park B...

  20. Effect of treated and untreated domestic wastewater on seed germination, seedling growth and amylase and lipase activities in Avena sativa L.

    Science.gov (United States)

    Fendri, Imen; Ben Saad, Rania; Khemakhem, Bassem; Ben Halima, Nihed; Gdoura, Radhouane; Abdelkafi, Slim

    2013-05-01

    Oats (Avena sativa L.) are a potential economically viable source of lipids and starch for use in foods. The aim of this study was to determine the effect of treated and untreated urban wastewater on seed germination, growth parameters and lipase and amylase activities in A. sativa. Untreated wastewater was highly toxic in nature and had an inhibitory effect on seed germination and seedling growth. However, after bacterial treatment, its toxicity was significantly reduced and it showed improved seed germination. It was observed that treated wastewater had no inhibitory effect on seedling growth parameters. However, A. sativa seeds treated with untreated effluent showed reduced lipase and amylase activities. Treated wastewater could be used for irrigation purposes provided that it satisfies other conditions fixed by legislation. © 2012 Society of Chemical Industry.

  1. GEOTECHNICAL PROPERTIES OF SANDY SOIL CONTAMINATED WITH INDUSTRIAL WASTEWATER

    Directory of Open Access Journals (Sweden)

    MAHDI O. KARKUSH

    2017-12-01

    Full Text Available The present work is devoted for studying the geotechnical and chemical properties of intact and contaminated sandy soil samples. The soil samples were obtained from Al-Kufa city that is located in the south-west of Iraq. The contaminant is a by-product industrial wastewater disposed from the refinery that supplies fuel for the thermal electricity power plant. The intact sandy soil samples were contaminated in the laboratory with four percentages of 10, 20, 40 and 100% of the weight of distilled water used in the soaking process and the soaking process continued for thirty days. The results of tests showed a slight increase in both liquid limit and particle size and a significant increase in the optimum moisture content with increasing the percentages of the contaminant. However, with increasing the percentages of the contaminant, there was a slight decrease in the specific gravity and maximum dry unit weight. In addition, there was a considerable decrease in the angle of internal friction and the coefficient of permeability. The angle of internal friction of contaminated soil samples decreased by 18 to 26% with increasing the contaminant percentage from 10 to 100%. The cohesion of soil samples decreased by 7 to 33% with increasing the contaminant percentage, this conclusion is limited to the soil samples contaminated with 10, 20 and 40%, but the cohesion of soil sample contaminated with 100 % of industrial wastewater increased by 7%.

  2. The sustainable utilization of malting industry wastewater biological treatment sludge

    Science.gov (United States)

    Vasilenko, T. A.; Svintsov, A. V.; Chernysh, I. V.

    2018-01-01

    The article deals with the research of using the sludge from malting industry wastewater’s biological treatment and the calcium carbonate slurry as organo-mineral fertilizing additives. The sludge, generated as a result of industrial wastewater biological treatment, is subject to dumping at solid domestic waste landfills, which has a negative impact on the environment, though its properties and composition allow using it as an organic fertilizer. The physical and chemical properties of both wastes have been studied; the recommendations concerning the optimum composition of soil mix, containing the above-mentioned components, have been provided. The phytotoxic effect on the germination capacity and sprouts of cress (Lepidium sativum), barley (Hordéum vulgáre) and oats (Avena sativa) in soil mixes has been determined. The heavy metals and arsenic contents in the sludge does not exceed the allowable level; it is also free of pathogenic flora and helminthes.

  3. REUSE OF TREATED WASTEWATER IN AGRICULTURE: SOLVING WATER DEFICIT PROBLEMS IN ARID AREAS (REVIEW

    Directory of Open Access Journals (Sweden)

    Faissal AZIZ

    2014-12-01

    Full Text Available In the arid and semiarid areas, the availability and the management of irrigation water have become priorities of great importance. The successive years of drought, induced by climate change and population growth, increasingly reduced the amount of water reserved for agriculture. Consequently, many countries have included wastewater reuse as an important dimension of water resources planning. In the more arid areas wastewater is used in agriculture, releasing high resource of water supplies. In this context, the present work is a review focusing the reuse of treated wastewater in agriculture as an important strategy for solving water deficit problems in arid areas. Much information concerning the wastewater reuse in different regions of the world and in Morocco, the different wastewater treatment technologies existing in Morocco were discussed. The review focused also the fertilizing potential of wastewater in agriculture, the role of nutrients and their concentrations in wastewater and their advantages effects on plant growth and yield.

  4. Removal of metals from industrial wastewater and urban runoff by mineral and bio-based sorbents.

    Science.gov (United States)

    Gogoi, Harshita; Leiviskä, Tiina; Heiderscheidt, Elisangela; Postila, Heini; Tanskanen, Juha

    2018-03-01

    The study was performed to evaluate chemically modified biosorbents, hydrochloric acid treated peat (HCl-P) and citric acid treated sawdust (Citric acid-SD) for their metal removal capacity from dilute industrial wastewater and urban runoff and compare their efficiency with that of commercially available mineral sorbents (AQM PalPower M10 and AQM PalPower T5M5 magnetite). Batch and column experiments were conducted using real water samples to assess the sorbents' metal sorption capacity. AQM PalPower M10 (consisting mainly of magnesium, iron and silicon oxides) exhibited excellent Zn removal from both industrial wastewater and spiked runoff water samples even at low dosages (0.1 g/L and 0.05 g/L, respectively). The high degree of Zn removal was associated with the release of hydroxyl ions from the sorbent and subsequent precipitation of zinc hydroxide. The biosorbents removed Ni and Cr better than AQM PalPower M10 from industrial wastewater and performed well in removing Cr and Cu from spiked runoff water, although at higher dosages (0.3-0.75 g/L). The main mechanism of sorption by biosorbents was ion exchange. The sorbents required a short contact time to reach equilibrium (15-30 min) in both tested water samples. AQM PalPower T5M5 magnetite was the worst performing sorbent, leaching Zn into both industrial and runoff water and Ni into runoff water. Column tests revealed that both HCl-P and AQM PalPower M10 were able to remove metals, although some leaching was witnessed, especially As from AQM PalPower M10. The low hydraulic conductivity observed for HCl-P may restrict the possibilities of using such small particle size peat material in a filter-type passive system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Evaluation of reusing alum sludge for the coagulation of industrial wastewater containing mixed anionic surfactants.

    Science.gov (United States)

    Jangkorn, Siriprapha; Kuhakaew, Sinchai; Theantanoo, Suwapee; Klinla-or, Harit; Sriwiriyarat, Tongchai

    2011-01-01

    A coagulation-flocculation process is typically employed to treat the industrial wastewater generated by the consumer products industry manufacturing detergents, soaps, and others. The expenditure of chemicals including coagulants and chemicals for pH adjustment is costly for treating this wastewater. The objective of this study was to evaluate the feasibility of reusing the aluminum sulfate (alum) sludge as a coagulant or as a coagulation aid so that the fresh alum dosage can be minimized or the removal efficiency can be enhanced. The experiments were conducted in a jar-test apparatus simulating the coagulation-flocculation process for simultaneous removals of organic matters, anionic surfactants, suspended solids, and turbidity. At the optimum initial pH value of 10 and the fresh alum concentration of 400 mg/L, the total suspended solids (TSS), total chemical oxygen demand (TCOD), total anionic surfactants, and turbidity removal efficiencies were 71.5%, 76.4%, 95.4%, and 98.2%, respectively. The addition of alum sludge as a coagulant alone without any fresh alum addition could significantly remove the turbidity, TCOD, and anionic surfactants. The TSS was left in the supernatants after the settling period, but would subsequently be removed by adding the fresh alum. The TSS, TCOD, and turbidity removal efficiencies were also enhanced when both the alum sludge and the fresh alum were employed. The TCOD removal efficiency over 80% has been accomplished, which has never fulfilled by using the fresh alum alone. It is concluded that the alum sludge could be reused for the treatment of industrial wastewater generated by the consumer products industry.

  6. 2016 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Cafferty, Kara Grace [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, Modification 1, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2015, through October 31, 2016.

  7. Distribution of free-living amoebae in a treatment system of textile industrial wastewater.

    Science.gov (United States)

    Ramirez, Elizabeth; Robles, Esperanza; Martinez, Blanca; Ayala, Reynaldo; Sainz, Guadalupe; Martinez, Maria Elena; Gonzalez, Maria Elena

    2014-11-01

    Free-living amoebae have been found in soil, air and a variety of aquatic environments, but few studies have been conducted on industrial wastewater and none on wastewater from the textile industry. The aim of this study was to determine the presence and distribution of free-living amoebae in a biological treatment system that treats textile industrial wastewater. Samples were taken from input, aeration tank, sedimentation tank and output. Samples were centrifuged at 1200g for 15min, the sediment was seeded on non-nutritive agar with Enterobacter aerogenes (NNE) and the plates were incubated at 30 and 37°C. Free-living amoebae were present in all stages of the treatment system. The highest number of amoebic isolates was found in the aeration tank and no seasonal distribution was observed during the year. A total of 14 amoeba genera were isolated: Acanthamoeba, Echinamoeba, Korotnevella, Mayorella, Naegleria, Platyamoeba, Saccamoeba, Stachyamoeba, Thecamoeba, Vahlkampfia, Vannella, Vermamoeba, Vexillifera and Willaertia. The most frequently found amoebae were Acanthamoeba and Vermamoeba which were found in all treatment system stages. The constant presence and diversity of free-living amoebae in the treatment system were important findings due to the characteristics of the wastewater from the textile plant in terms of the residue content from colorants, fixers, carriers, surfactants, etc., used in fabric dyeing and finishing processes. The factors that determined the presence and distribution of amoebae in the activated sludge system were their capacity to form cysts, which allowed them to resist adverse conditions; food availability; an average temperature of 27-33°C; dissolved oxygen in average concentrations above 2mg/L, and pH in a range of 5.9-7.1. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Evaluation of mutagenicity of wastewater in the vicinity of pesticide industry.

    Science.gov (United States)

    Anjum, Reshma; Malik, Abdul

    2013-03-01

    Pesticide industrial wastewater samples were taken from the Chinhat industrial area nearby Lucknow city, India. GC-MS analysis revealed the presence of pesticides lindane, α-endosulfan, β-endosulfan, chlorpyriphos, monocrotophos, dimethoate and malathion. A pesticide mixture and wastewater extracts were studied to determine the mutagenicity by Ames Salmonella test, survival of DNA repair defective E. coli K-12 mutants and bacteriophage λ systems. Wastewater samples were concentrated with XAD-resins as an adsorbent and liquid-liquid extraction procedure. The XAD concentrated sample exhibited maximum mutagenic activity in comparison to liquid-liquid extracted sample. TA98 strain was the most responsive strain for both test samples with (+S9) and without (-S9) metabolic activation, while other strains exhibited weak response. A significant decline of DNA repair defective E. coli K-12 mutants, bacteriophage λ was observed with test samples in the survival. The intracellular damage was highest when treated with XAD concentrated sample as compared to liquid-liquid extract after 6h treatment. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Risk assessment of irrigated lacustrine & calcareous soils by treated wastewater

    Directory of Open Access Journals (Sweden)

    Ibrahim H. Elsokkary

    2014-10-01

    Full Text Available The objectives of this study were to explore the effect of irrigation by treated wastewater (TWW on some chemical characteristics of cultivated lacustrine and calcareous soils, the growth and macronutrients contents of soybean, corn, faba bean and wheat; and the chemical composition and quality of drainage waters from these soils. For this, greenhouse experiments, using PVC tank of 50 kg soil capacity were carried out. The soils were irrigated by FW, TWW or 1:1 FW/TWW. The results suggest that tested plants can be irrigated with reused water since visual damage is minimal, which seems to be related to the plant's low accumulation of saline ions. The dilution of TWW with FW reduced the negative effects observed. The results have also shown a significant increase in the concentration of EC and in the counts of TC and FC in soils of the upper layer (0–20 cm than in those of the lower layer (20–40 cm.

  10. Wastewater and sludge control-technology options for synfuels industries

    Energy Technology Data Exchange (ETDEWEB)

    Castaldi, F.J.; Harrison, W.; Ford, D.L.

    1981-02-01

    The options examined were those of zero discharge, partial water reuse with restricted discharge of treated effluents, and unrestricted discharge of treated effluents. Analysis of cost data and performance-analyses data for several candidate secondary-wastewater-treatment unit processes indicated that combined activated-sludge/powdered-activated-carbon (AS/PAC) treatment incorporating wet-air-oxidation carbon regeneration is the most cost-effective control technology available for the removal of organic material from slagging, fixed-bed process wastewaters. Bench-scale treatability and organic-constituent removal studies conducted on process quench waters from a pilot-scale, slagging, fixed-bed gasifer using lignite as feedstock indicated that solvent extraction followed by AS/PAC treatment reduces levels of extractable and chromatographable organics to less than 1 ..mu..g/L in the final effluent. Levels of conventional pollutants also were effectively reduced by AS/PAC to the minimum water-quality standards for most receiving waters. The most favored and most cost-effective treatment option is unrestricted discharge of treated effluents with ultimate disposal of biosludges and landfilling of gasifier ash and slag. This option requires a capital expenditure of $8,260,000 and an annual net operating cost of $2,869,000 in 1978 dollars, exclusive of slag disposal. The net energy requirement of 19.6 x 10/sup 6/ kWh/year, or 15.3 kWh/1000 gal treated, is less than 6% of the equivalent energy demand associated with the zero-discharge option.

  11. The status of wastewater management in Shokuhieh industrial park (A case study of Qom province

    Directory of Open Access Journals (Sweden)

    Mohammad Fahiminia

    2015-12-01

    Full Text Available Background: Water resource management is a strategic issue in Qom city. Water scarcity is one of the most critical concerns of industrial estates. This study aimed to evaluate wastewater management in the Shokuhieh industrial park of Qom province in 2013. Methods: This is a descriptive cross-sectional study done by visiting the industrial units in person, completing questionnaires and analyzing the results. The questionnaire had 25 questions, including general information, the status of water supply, treatment and consumption, wastewater production, reuse or discharge of produced wastewater and the status of wastewater treatment and discharge of effluent. The industrial units evaluated were active with over 50 personnel and numbered 44 in total. Results: The water suppliers in the industries included network (70.5%, network and reverse osmosis (RO (22.5%, network and tanker (2.4% and tanker (4.6%. 63.63% of the industries had water treatment systems. 19.5% reused wastewater and 31.8% performed pretreatment before discharge of wastewater. The discharge sites of water treatment units’ effluent included the absorption well (17%, greenbelt (18% and sewer (65%. Discharge sites of sanitary wastewater in 50% of the industries was sewer and in 50%, it was absorption well. The discharge sites of processed wastewater was reuse (2%, sewer (52% and absorption well (46%. Discharge sites of exiting effluent from pretreatment units in the industrial park, included sewer (85.5%, transport by tanker (7.1% and absorption well (7.1%. The type of pretreatment process in 35.7% of the industries was chemical and in 64.3%, it was septic tank. Conclusion: The results of this study showed that pre-treatment is not done in most industries and wastewater reuse is performed in few industries. The main method of wastewater disposal in industries was by discharge into the sewer and absorbent well.

  12. Comparative study on toxicity evaluation of anaerobically treated parboiled rice manufacturing wastewater through fish bioassay.

    Science.gov (United States)

    Giri, Dipti Ramesh; Singh, Ekta; Satyanarayan, Shanta

    2016-01-01

    Short term aquatic bioassay has been developed into a useful tool in water quality management. These tests give information on comparative toxicity of several compounds. The objective of this study was to evaluate the acute toxicity of raw and anaerobically treated effluents of the parboiled rice manufacturing industry. The acute toxicity test was carried out by using the fish Lebistes reticulatus under laboratory conditions. LC50 values for 24, 48, 72 and 96 hours ranged between 4.6 and 7.0% for the raw parboiled rice manufacturing wastewater. Two anaerobic fixed film fixed bed reactors and two different media matrices, i.e. UV stabilized Biopac media and Fugino spirals, were used for the treatment of parboiled rice mill wastewater. Effluents from these two reactors depicted LC50 values in the range of 68-88% and 62-78% for Biopac and Fugino spiral packed reactors, respectively. From the results, it is evident that anaerobically treated effluents from Biopac packed reactor is marginally better than Fugino spiral packed reactor. Results subjected to statistical evaluation depicted regression coefficient of more than 0.9 indicating good correlation between the mortality and effluent concentration.

  13. Agricultural use of treated wastewater: the need for a paradigm shift in sanitation & treatment

    NARCIS (Netherlands)

    Lier, van J.B.; Huibers, F.P.

    2004-01-01

    Appropriate treated domestic sewage can be regarded as iseal for irrigation and fertilization purposes, particularly in the (semi)arid climate region. This contribution focuses on: 1) pathogens, various levels of interception; 2) basic wastewater treatment; 3) wastewater treatment for effluent use

  14. The investigation of paper mill industry wastewater treatment and activated sludge properties in a submerged membrane bioreactor.

    Science.gov (United States)

    Erkan, Hanife Sari; Engin, Guleda Onkal

    2017-10-01

    The paper mill industry produces high amounts of wastewater and, for this reason, stringent discharge limits are applied for sustainable reclamation and reuse of paper mill industry wastewater in many countries. Submerged membrane bioreactor (sMBR) systems can create new opportunities to eliminate dissolved substances present in paper mill wastewater including. In this study, a sMBR was operated for the treatment of paper mill industry wastewater at 35 h of hydraulic retention time (HRT) and 40 d of sludge retention time (SRT). The chemical oxygen demand (COD), NH 3 -N and total phosphorus (TP) removal efficiencies were found to be 98%, 92.99% and 96.36%. The results demonstrated that sMBR was a suitable treatment for the removal of organic matter and nutrients for treating paper mill wastewater except for the problem of calcium accumulation. During the experimental studies, it was noted that the inorganic fraction of the sludge increased as a result of calcium accumulation in the reactor and increased membrane fouling was observed on the membrane surface due to the calcification problem encountered. The properties of the sludge, such as extracellular polymeric substances (EPS) and soluble microbial products (SMP), relative hydrophobicity, zeta potential and floc size distribution were also monitored. According to the obtained results, the total EPS was found to be 43.93 mg/gMLSS and the average total SMP rejection by the membrane was determined as 66.2%.

  15. Preliminary Assessment of Growth Rates on Different Concentration of Microalgae Scenedesmus sp. in Industrial Meat Food Processing Wastewater

    Directory of Open Access Journals (Sweden)

    Latiffi Nur Atikah Ahmad

    2017-01-01

    Full Text Available This study is aimed to evaluate and access the growth rates and biomass productivity in different concentrations of microalgae Scenedesmus sp. using Industrial Meat Food Processing Wastewater as a media. The focus of this study is to determine the best concentrations of microalgae Scenedesmus sp. in raw wastewater in terms of kinetics of cells growth rates. The study verified that concentration of 1×106 cells/ml of microalgae gives the highest specific growth rates of biomass at 0.4488 day-1 and 1720 cells/ml/day compare to the other concentrations, while the lowest occurred at concentration of 1×103 cells/ml at 0.4108 day-1 and 14.9 cells/ml/day. The result shows the different concentration of microalgae Scenedesmus sp. culturing in Industrial Food Processing Wastewater influence the cells growth of biomass and the optimum were obtained at concentration of 1×106 cells/ml which suggested use for Industrial Meat Food Processing Wastewater Treatment purposed. With this finding, it should be seemly to adopt and applied efficiently in treating the wastewater especially for Scenedesmus sp. type of microalgae.

  16. Nitrogen removal in Northern peatlands treating mine wastewaters

    Science.gov (United States)

    Palmer, Katharina; Karlsson, Teemu; Turunen, Kaisa; Liisa Räisänen, Marja; Backnäs, Soile

    2015-04-01

    Natural peatlands can be used as passive purification systems for mine wastewaters. These treatment peatlands are well-suited for passive water treatment as they delay the flow of water, and provide a large filtration network with many adsorptive surfaces on plant roots or soil particles. They have been shown to remove efficiently harmful metals and metalloids from mine waters due to variety of chemical, physical and biological processes such as adsorption, precipitation, sedimentation, oxidation and reduction reactions, as well as plant uptake. Many factors affect the removal efficiency such as inflow water quality, wetland hydrology, system pH, redox potential and temperature, the nature of the predominating purification processes, and the presence of other components such as salts. However, less attention has been paid to nitrogen (N) removal in peatlands. Thus, this study aimed to assess the efficiency of N removal and seasonal variation in the removal rate in two treatment peatlands treating mine dewatering waters and process effluent waters. Water sampling from treatment peatland inflow and outflow waters as well as pore waters in peatland were conducted multiple times during 2012-2014. Water samples were analysed for total N, nitrate-N and ammonium-N. Additionally, an YSI EXO2 device was used for continuous nitrate monitoring of waters discharged from treatment peatlands to the recipient river during summer 2014. The results showed that the oxic conditions in upper peat layer and microbial activity in treatment peatlands allowed the efficient oxidation of ammonium-N to nitrite-N and further to nitrate-N during summer time. However, the slow denitrification rate restricts the N removal as not all of the nitrate produced during nitrification is denitrified. In summer time, the removal rate of total N varied between 30-99 % being highest in late summer. N removal was clearly higher for treatment peatland treating process effluent waters than for peatland

  17. Fungal biotrap for retrieval of heavy metals from industrial wastewaters

    International Nuclear Information System (INIS)

    Crusberg, T.C.; Weathers, P.; Baker, E.

    1989-01-01

    Biotraps are living cells or specific cell components capable of removing or stabilizing toxic substances form waste streams. The fungus Penicillium ochro-chloron was discovered growing in an electroplating wastewater stream in Japan. It is not only tolerant to very high concentrations of divalent metal ions, but it can effectively remove heavy metals (such as uranium cadmium, nickel, etc.) from almost any aqueous waste stream. This paper discussed P. ochro-chloron biotrap which was prepared by growing spores in a glucose-minimal salts medium supplemented with 0.5 percent Tween 80 for 5 days with constant gentle agitation. The while mycelia beads 4-6 mm dia. were treated in a Buchner funnel with 80% ethanol to kill the cells, 15 percent sodium carbonate/bicarbonate pH 9.5, and then resuspended in an aqueous slurry at pH 4.0. The mycelia beads were used as an adsorbent in a batch experiment to determine copper-to-mycelia binding. This system should be capable of heavy metal uptake and recovery from both electroplating wastewaters and contaminated aqueous environments. The use of this fungus biotrap will rival synthetic cation environments. The use of this fungus biotrap will rival synthetic cation exchange resins because of lower cost, lower weight per unit of exchange capacity and ease of application

  18. Antibiotic resistance along an urban river impacted by treated wastewaters.

    Science.gov (United States)

    Proia, Lorenzo; Anzil, Adriana; Subirats, Jessica; Borrego, Carles; Farrè, Marinella; Llorca, Marta; Balcázar, Jose Luis; Servais, Pierre

    2018-07-01

    Urban rivers are impacted ecosystems which may play an important role as reservoirs for antibiotic-resistant (AR) bacteria. The main objective of this study was to describe the prevalence of antibiotic resistance along a sewage-polluted urban river. Seven sites along the Zenne River (Belgium) were selected to study the prevalence of AR Escherichia coli and freshwater bacteria over a 1-year period. Culture-dependent methods were used to estimate E. coli and heterotrophic bacteria resistant to amoxicillin, sulfamethoxazole, nalidixic acid and tetracycline. The concentrations of these four antibiotics have been quantified in the studied river. The antibiotic resistance genes (ARGs), sul1, sul2, tetW, tetO, blaTEM and qnrS were also quantified in both particle-attached (PAB) and free-living (FLB) bacteria. Our results showed an effect of treated wastewaters release on the spread of antibiotic resistance along the river. Although an increase in the abundance of both AR E. coli and resistant heterotrophic bacteria was observed from upstream to downstream sites, the differences were only significant for AR E. coli. A significant positive regression was also found between AR E. coli and resistant heterotrophic bacteria. The concentration of ARGs increased from upstream to downstream sites for both particle-attached (PAB) and free-living bacteria (FLB). Particularly, a significant increase in the abundance of four among six ARGs analyzed was observed after crossing urban area. Although concentrations of tetracycline significantly correlated with tetracycline resistance genes, the antibiotic levels were likely too low to explain this correlation. The analysis of ARGs in different fractions revealed a significantly higher abundance in PAB compared to FLB for tetO and sul2 genes. This study demonstrated that urban activities may increase the spread of antibiotic resistance even in an already impacted river. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Wastewater Management Efficiency and Determinant Factors in the Chinese Industrial Sector from 2004 to 2014

    Directory of Open Access Journals (Sweden)

    Hidemichi Fujii

    2017-08-01

    Full Text Available This study analyzes industrial wastewater management efficiency using a Chinese provincial dataset from 2004 to 2014. The weighted Russell directional distance model is used to evaluate the efficiency of management practices. Determinants analysis was conducted based on governmental policy, pollution abatement, and market factors to identify the main drivers of industrial wastewater management efficiency in China. The results indicate that the wastewater management efficiency improved in the eastern and central regions. However, there is a significant efficiency gap between provinces in the western region. Moreover, the main determinants of wastewater management efficiency differ among regions and pollutants.

  20. Oxidation of Mixed Active Pharmaceutical Ingredients in Biologically Treated Wastewater by ClO2

    DEFF Research Database (Denmark)

    Moradas, Gerly; Fick, Jerker; Ledin, Anna

    2011-01-01

    Biologically treated wastewater containing a mixture of 53 active pharmaceutical ingredients (APIs)was treated with 0-20 mg/l chlorine dioxide (ClO2) solution. Wastewater effluents were taken from two wastewater treatment plants in Sweden, one with (low COD) and one without (high COD) extended...... removed at 5 mg/l ClO2 dose. Removal of the same APIs from the high COD effluent was observed when the ClO2 dose was increased to 1.25 mg/l and an increase in API removal only after treatment with 8 mg/l ClO2. This illustrates that treatment of wastewater effluents with chlorine dioxide has potential...... to remove pharmaceuticals traces from wastewater treatment plant effluents....

  1. Synthesis of BiOCl using Cl source from industrial wastewater and its application for wastewater treatment.

    Science.gov (United States)

    Yao, Kun; Jia, Manke; Wu, Huanhuan; Li, Yonggang; Chen, Chuncheng; Huang, Yingping

    2017-11-03

    Cl - in industrial wastewater from glyphosate production has been used as Cl source to synthesize BiOCl photocatalyst via a simple solvothermal route. The crystalline, morphology, specific surface area and optical properties of photocatalysts prepared under various conditions have been investigated. BiOCl photocatalyst prepared in acidic solution shows the highest crystallinity and without impurities and microcellular structure. The degradation of industrial wastewater contaminants demonstrates the possibility of this BiOCl used in industrial wastewater treatment and phosphorus recycling through the subsequent phosphorus recovery processes. This study not only sheds light on the possibility of photocatalysts' preparation in situ using industrial wasterwater as raw materials and the feasibility of using photocatalysis technology in wastewater treatment area, but also the chloride ions have been removed as an available resource and the corrosion to treatment facilities has been slowed down. The phosphorus and nitrogen resources can be recycled by other subsequent recycle recoveries. It offers a novel way for the wastewater treatment process in succession from photocatalysts' manufacture to contaminants disposal.

  2. Inactivation of microorganisms in treated municipal wastewater and biosolids by gamma irradiation

    International Nuclear Information System (INIS)

    2009-01-01

    Increasing growth of the world's population, waste minimization policies and agricultural needs make the recycling of domestic wastewater quite a desirable practice. Factors like environmental and public health risks must be taken into account when considering treated wastewater for field irrigation and biosolids for land application. Pathogens present in wastewater and biosolids may remain active after treatment and there is always a great risk of transmission of infections via consuming crop and vegetables. Therefore it is very important to treat domestic wastewater properly before using it as an irrigation water and as a fertilizer. The work reported herein represents an evaluation of the variations in the population densities of below indicated pathogens monitored during a one year study in Ankara Central Municipal Wastewater Treatment Plant, and the efficiency of gamma irradiation for the inactivation of these important waterborne pathogens. Parasitological investigation Treated wastewater and biosolids - Cryptosporidium sp. - Giardia lamblia - Entamoeba histolytica - Cyclospora cayetanensis - Helminth ova Bacteriological investigation Treated wastewater - Total coliforms - Salmonella sp. - Fecal streptococci - Enterococcus sp. Biosolids - Fecal coliforms - Salmonella sp. (Includes 12 tables, 16 figures)

  3. Effect of using dissolved air flotation system on industrial wastewater treatment in pilot scale

    International Nuclear Information System (INIS)

    Yahya, Habibzadeh

    2010-01-01

    In the present paper the application of Dissolved Air Flotation (DAF) system for wastewater treatment, especially for industrial wastewater on a designed pilot system has been investigated. It is for the first time in dissolved air flotation system that instead of air dissolving tube, hydro cyclone technology is used to dissolve air in water with ratio of 1:1 (almost 100 percent) in the form of small air bubbles and a circular flotation tank instead of rectangular tank. The advantage of usage of circular tank in DAF system is the capability of being treated in higher rate of mass, so less space is needed. Although application of hydro cyclone with different diameters of holes for producing mixing energy which also has the capability of direct injection of chemical coagulant and polymeric materials leads to the higher efficiency of treatment and so reduces the cost of pump and consumed air. Investigations on the efficiency of this system was done by providing and analyzing samples of wastewater with and without adding of PAC (Poly-Aluminium-Chloride). Sampling and analyzing was done according to standard methods. The results of the analyses show that pilot system has high efficiency, especially for oil removal

  4. Fungal treatment of humic-rich industrial wastewater: application of white rot fungi in remediation of food-processing wastewater.

    Science.gov (United States)

    Zahmatkesh, Mostafa; Spanjers, Henri; van Lier, Jules B

    2017-11-01

    This paper presents the results of fungal treatment of a real industrial wastewater (WW), providing insight into the main mechanisms involved and clarifying some ambiguities and uncertainties in the previous reports. In this regard, the mycoremediation potentials of four strains of white rot fungi (WRF): Phanerochaete chrysosporium, Trametes versicolor, Pleurotus ostreatus and Pleurotus pulmonarius were tested to remove humic acids (HA) from a real humic-rich industrial treated WW of a food-processing plant. The HA removal was assessed by color measurement and size-exclusion chromatography (SEC) analysis. T. versicolor showed the best decolorization efficiency of 90% and yielded more than 45% degradation of HA, which was the highest among the tested fungal strains. The nitrogen limitation was studied and results showed that it affected the fungal extracellular laccase and manganese peroxidase (MnP) activities. The results of the SEC analysis revealed that the mechanism of HA removal by WRF involves degradation of large HA molecules to smaller molecules, conversion of HA to fulvic acid-like molecules and also biosorption of HA by fungal mycelia. The effect of HS on the growth of WRF was investigated and results showed that the inhibition or stimulation of growth differs among the fungal strains.

  5. Removal of Phenol from Synthetic and Industrial Wastewater by Potato Pulp Peroxidases.

    Science.gov (United States)

    Kurnik, Katarzyna; Treder, Krzysztof; Skorupa-Kłaput, Monika; Tretyn, Andrzej; Tyburski, Jarosław

    Plant peroxidases have strong potential utility for decontamination of phenol-polluted wastewater. However, large-scale use of these enzymes for phenol depollution requires a source of cheap, abundant, and easily accessible peroxidase-containing material. In this study, we show that potato pulp, a waste product of the starch industry, contains large amounts of active peroxidases. We demonstrate that potato pulp may serve as a tool for peroxidase-based remediation of phenol pollution. The phenol removal efficiency of potato pulp was over 95 % for optimized phenol concentrations. The potato pulp enzymes maintained their activity at pH 4 to 8 and were stable over a wide temperature range. Phenol solutions treated with potato pulp showed a significant reduction in toxicity compared with untreated phenol solutions. Finally we determined that this method may be employed to remove phenol from industrial effluent with over 90 % removal efficiency under optimal conditions.

  6. Electricity Production and Characterization of High-Strength Industrial Wastewaters in Microbial Fuel Cell.

    Science.gov (United States)

    Cetinkaya, Afsin Y; Ozdemir, Oguz Kaan; Demir, Ahmet; Ozkaya, Bestami

    2017-06-01

    Microbial fuel cells (MFCs) convert electrochemical energy into electrical energy immediately and have a big potential usage for the same time wastewater treatment and energy recovery via electro-active microorganisms. However, MFCs must be efficiently optimized due to its limitations such as high cost and low power production. Finding new materials to increase the cell performance and reduce cost for MFC anodes is mandatory. In the first step of this study, different inoculation sludges such as anaerobic gum industry wastewater, anaerobic brewery wastewater and anaerobic phosphate were tested, and MFC that was set up with anaerobic gum industry wastewater inoculation sludge exhibited the highest performance. In the second step of this study, various wastewaters such as chocolate industry, gum industry and slaughterhouse industry were investigated for anode bacteria sources. Several electrochemical techniques have been employed to elucidate how wastewaters affect the MFCs' performance. Among all the mentioned wastewaters, the best performance was achieved by the MFCs fed with slaughterhouse wastewater; this device produced a maximum power density of 267 mW·m -2 .

  7. TREATMENT OF WASTEWATER IN PLATING INDUSTRY BY CHELATE EXTRACTION METHOD

    Directory of Open Access Journals (Sweden)

    M. R. Massoudi Nejad, M. Rezazadeh Azary, M. Khatiby

    2007-01-01

    Full Text Available One of the most efficient methods to preserve environment is the procedure and method to achieve effective materials and the dual and reapplication of natural sources. In this research, After carrying out a vast study on the growing spot of Iranian oaks , of the 36 species and subspecies already identified, 10 species and subspecies were selected as they cover a vaster surface of Iranian woods in North Alborz Region, Arsabaran region and the western part of Zagros Mountains. 5 samples were collected of each type form diffrenet spots of the country. The effective and usable substances of oak fruit were extracted and isolated by the four methods of maceration, decoction, perculation and soxhlet tannin in one specie show no significant difference; However the amount of tannin in different species show significant differences in statistical term in such a way that the minimum and maximum tannin was found in Q.Brantii, Belangri with 9.7% tannin and Q.Macrantera, with 3.2 percent tannin. This amount was put in contact with wastewater various from plating industries in 20 to 50 mg/L amount. The mentioned wastewaters contained 50 to 750 mg/L heavy metals (chromium, nickel, zinc, copper and silver. The results were analyzed through a biofactor variance analysis model with repetition in each house (Toki Results showed that the removal output for zinc, copper, nickel and chromium without considering the initial concentration of the metal were 91 to 95 percent, 71 to 83.5 percent, 59 to 90 percent, and 84 to 85 percent, respectively. Also, with repect to the studies carried out with different methods and comparing the percentage of metals removal it was concluded that the removals output through applying 50 mg/L. hydroxide calcium along with 50 mg/L tannin with 82.3 percent average had the most effects in entire metals.

  8. Wastewater treatment in the pulp-and-paper industry: A review of treatment processes and the associated greenhouse gas emission.

    Science.gov (United States)

    Ashrafi, Omid; Yerushalmi, Laleh; Haghighat, Fariborz

    2015-08-01

    Pulp-and-paper mills produce various types of contaminants and a significant amount of wastewater depending on the type of processes used in the plant. Since the generated wastewaters can be potentially polluting and very dangerous, they should be treated in wastewater treatment plants before being released to the environment. This paper reviews different wastewater treatment processes used in the pulp-and-paper industry and compares them with respect to their contaminant removal efficiencies and the extent of greenhouse gas (GHG) emission. It also evaluates the impact of operating parameters on the performance of different treatment processes. Two mathematical models were used to estimate GHG emission in common biological treatment processes used in the pulp-and-paper industry. Nutrient removal processes and sludge treatment are discussed and their associated GHG emissions are calculated. Although both aerobic and anaerobic biological processes are appropriate for wastewater treatment, their combination known as hybrid processes showed a better contaminant removal capacity at higher efficiencies under optimized operating conditions with reduced GHG emission and energy costs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Pollution prevention and wastewater treatment in fish canning industries of Northern Portugal

    OpenAIRE

    Cristovão, Raquel; Martins, Ramiro; Boaventura, Rui

    2012-01-01

    The main environmental problems of fish canning industries are high water consumption and high organic matter, oil and grease and salt content in their wastewaters. This work aims to analyze the situation (water consumption, wastewater production, wastewater characterization, etc.) of different plants located north of Douro river, in Portugal, in order to propose various solutions to their problems. Thus, initially it was made an identification and implementation of prevent and control pollut...

  10. Wastewater Management in Shale Gas Industry: Alternatives for Water Reuse and Recycling, Challenges and Perspectives

    OpenAIRE

    Onishi, Viviani C.; Reyes-Labarta, Juan A.; Caballero, José A.; Antunes, Carlos H.

    2017-01-01

    18th European Meeting on Environmental Chemistry (EMEC). Poster (#22) http://emec18.eventos.chemistry.pt/ Wastewater management is nowadays one of the major concerns faced by the shale gas industry to improve its cost-effectiveness, while preserving the human health and environment. Horizontal drilling and hydraulic fracturing operations usually demand excessive freshwater consumption and generate large wastewater volumes. The highly polluting nature of shale gas wastewater impels the appl...

  11. The functional and physiological status of Gammarus fossarum (Crustacea; Amphipoda) exposed to secondary treated wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Bundschuh, Mirco, E-mail: bundschuh@uni-landau.d [Institute for Environmental Sciences, University of Koblenz-Landau, Fortstrasse 7, D-76829 Landau, Rhineland-Palatinate (Germany); Zubrod, Jochen P.; Schulz, Ralf [Institute for Environmental Sciences, University of Koblenz-Landau, Fortstrasse 7, D-76829 Landau, Rhineland-Palatinate (Germany)

    2011-01-15

    Climate change scenarios predict lower flow rates during summer that may lead to higher proportions of wastewater in small and medium sized streams. Moreover, micropollutants (e.g. pharmaceuticals and other contaminants) continuously enter aquatic environments via treated wastewater. However, there is a paucity of knowledge, whether extended exposure to secondary treated wastewater disrupts important ecosystem functions, e.g. leaf breakdown. Therefore, the amphipod shredder Gammarus fossarum was exposed to natural stream water (n = 34) and secondary treated wastewater (n = 32) for four weeks in a semi-static test system under laboratory conditions. G. fossarum exposed to wastewater showed significant reductions in feeding rate (25%), absolute consumption (35%), food assimilation (50%), dry weight (18%) and lipid content (22%). Thus, high proportions of wastewater in the stream flow may affect both the breakdown rates of leaf material and thus the availability of energy for the aquatic food web as well as the energy budget of G. fossarum. - Micropollutants in wastewater cause functional and physiological alteration in a leaf-shredding amphipod.

  12. Preparation of activated carbon from walnut shell and its application in industrial wastewater

    Science.gov (United States)

    Jiang, Yilin

    2017-05-01

    With the development of China's industry, the content of heavy metal ions in wastewater is increasing. In this paper, analyzed the performance of activated carbon prepared from walnut shell by chemical activation method, and conduct the experimental research on the factors influencing the performance of activated carbon by using the control variable method. The best method for preparing activated carbon from walnut shell was put forward. In the industrial wastewater treatment technology to lay the foundation for the application. Lay the foundation for the promotion of industrial wastewater treatment technology.

  13. Chemical properties of a Haplustalf soil under irrigation with treated wastewater and nitrogen fertilization

    Directory of Open Access Journals (Sweden)

    Leda V. B. D. Silva

    2016-04-01

    Full Text Available ABSTRACT The objective of this research was to investigate the effects of irrigation with treated wastewater and nitrogen (N fertilization on the chemical characteristics of a Haplustalf soil cultivated with cotton. An experiment was conducted in a greenhouse in a completely randomized design with four replicates, and arranged in a 5 x 4 factorial. Five doses of N fertilization (0, 45, 90, 135 and 180 kg ha-1 and four sources of irrigation water (freshwater, wastewater treated by an anaerobic reactor, wastewater treated by an anaerobic reactor and post-treated by intermittent sand filter in series, wastewater treated in a septic tank and post-treated by an intermittent sand filter were tested. Irrigation was daily performed from July 2011 to January 2012 according to the water demand of cotton resulting in a water depth of 620 mm. It was found that, compared with the conventional management with freshwater irrigation, treated wastewater provides greater accumulation of micronutrient, potassium and sodium in the soil, increasing the risk of sodification in irrigated areas.

  14. Electrochemical generation of fentons reagent to treat spent caustic wastewater

    International Nuclear Information System (INIS)

    Hansen, H. K.; Nunez, P.; Rodriguez, N.; Guzman, J.

    2009-01-01

    An important wastewater stream from oil refineries is the spent caustic. Caustic solutions are used as scrubbing agent during the desulphurization process to eliminate sulphur an mercaptans from oil and gasses. Spent caustic is classified as DOO3 (reactive sulphide) hazardous waste under the US Resource Conservation and Recovery Act (RCRA). (Author)

  15. A national discharge load of perfluoroalkyl acids derived from industrial wastewater treatment plants in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee-Young; Seok, Hyun-Woo [Department of Civil and Environmental Engineering, Pusan National University, Busan 46241 (Korea, Republic of); Kwon, Hye-Ok; Choi, Sung-Deuk [School of Urban and Environmental Engineering, Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); Seok, Kwang-Seol [Chemical Research Division, National Institute of Environmental Research, Incheon 22689 (Korea, Republic of); Oh, Jeong Eun [Department of Civil and Environmental Engineering, Pusan National University, Busan 46241 (Korea, Republic of)

    2016-09-01

    Levels of 11 perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS), were measured in wastewater (influent and effluent) and sludge samples collected from 25 industrial wastewater treatment plants (I-WWTPs) in five industrial sectors (chemicals, electronics, metals, paper, and textiles) in South Korea. The highest ∑{sub 11}PFAAs concentrations were detected in the influent and effluent from the paper (median: 411 ng/L) and textile (median: 106 ng/L) industries, and PFOA and PFOS were the predominant PFAAs (49–66%) in wastewater. Exceptionally high levels of PFAAs were detected in the sludge associated with the electronics (median: 91.0 ng/g) and chemical (median: 81.5 ng/g) industries with PFOS being the predominant PFAA. The discharge loads of 11 PFAAs from I-WWTP were calculated that total discharge loads for the five industries were 0.146 ton/yr. The textile industry had the highest discharge load with 0.055 ton/yr (PFOA: 0.039 ton/yr, PFOS: 0.010 ton/yr). Municipal wastewater contributed more to the overall discharge of PFAAs (0.489 ton/yr) due to the very small industrial wastewater discharge compared to municipal wastewater discharge, but the contribution of PFAAs from I-WWTPs cannot be ignored. - Highlights: • 11 PFAAs in wastewater and sludge from 5 industrial sectors were investigated. • PFOA and PFOS were the dominant in wastewater while PFOS was predominant in sludge. • The total discharge loads from 5 industrial sectors 0.146 ton/yr. • The textile industry showed the highest discharge load with 0.055 ton/yr.

  16. Application of a continuously stirred tank bioreactor (CSTR) for bioremediation of hydrocarbon-rich industrial wastewater effluents

    Energy Technology Data Exchange (ETDEWEB)

    Gargouri, Boutheina; Karray, Fatma; Mhiri, Najla; Aloui, Fathi [Laboratoire des Bioprocedes Environnementaux, Pole d' Excellence Regional AUF-LBPE, Centre de Biotechnologie de Sfax, Universite de Sfax, BP 1117, 3018 Sfax (Tunisia); Sayadi, Sami, E-mail: sami.sayadi@cbs.rnrt.tn [Laboratoire des Bioprocedes Environnementaux, Pole d' Excellence Regional AUF-LBPE, Centre de Biotechnologie de Sfax, Universite de Sfax, BP 1117, 3018 Sfax (Tunisia)

    2011-05-15

    A continuously stirred tank bioreactor (CSTR) was used to optimize feasible and reliable bioprocess system in order to treat hydrocarbon-rich industrial wastewaters. A successful bioremediation was developed by an efficient acclimatized microbial consortium. After an experimental period of 225 days, the process was shown to be highly efficient in decontaminating the wastewater. The performance of the bioaugmented reactor was demonstrated by the reduction of COD rates up to 95%. The residual total petroleum hydrocarbon (TPH) decreased from 320 mg TPH l{sup -1} to 8 mg TPH l{sup -1}. Analysis using gas chromatography-mass spectrometry (GC-MS) identified 26 hydrocarbons. The use of the mixed cultures demonstrated high degradation performance for hydrocarbons range n-alkanes (C10-C35). Six microbial isolates from the CSTR were characterized and species identification was confirmed by sequencing the 16S rRNA genes. The partial 16S rRNA gene sequences demonstrated that 5 strains were closely related to Aeromonas punctata (Aeromonas caviae), Bacillus cereus, Ochrobactrum intermedium, Stenotrophomonas maltophilia and Rhodococcus sp. The 6th isolate was affiliated to genera Achromobacter. Besides, the treated wastewater could be considered as non toxic according to the phytotoxicity test since the germination index of Lepidium sativum ranged between 57 and 95%. The treatment provided satisfactory results and presents a feasible technology for the treatment of hydrocarbon-rich wastewater from petrochemical industries and petroleum refineries.

  17. Application of a continuously stirred tank bioreactor (CSTR) for bioremediation of hydrocarbon-rich industrial wastewater effluents

    International Nuclear Information System (INIS)

    Gargouri, Boutheina; Karray, Fatma; Mhiri, Najla; Aloui, Fathi; Sayadi, Sami

    2011-01-01

    A continuously stirred tank bioreactor (CSTR) was used to optimize feasible and reliable bioprocess system in order to treat hydrocarbon-rich industrial wastewaters. A successful bioremediation was developed by an efficient acclimatized microbial consortium. After an experimental period of 225 days, the process was shown to be highly efficient in decontaminating the wastewater. The performance of the bioaugmented reactor was demonstrated by the reduction of COD rates up to 95%. The residual total petroleum hydrocarbon (TPH) decreased from 320 mg TPH l -1 to 8 mg TPH l -1 . Analysis using gas chromatography-mass spectrometry (GC-MS) identified 26 hydrocarbons. The use of the mixed cultures demonstrated high degradation performance for hydrocarbons range n-alkanes (C10-C35). Six microbial isolates from the CSTR were characterized and species identification was confirmed by sequencing the 16S rRNA genes. The partial 16S rRNA gene sequences demonstrated that 5 strains were closely related to Aeromonas punctata (Aeromonas caviae), Bacillus cereus, Ochrobactrum intermedium, Stenotrophomonas maltophilia and Rhodococcus sp. The 6th isolate was affiliated to genera Achromobacter. Besides, the treated wastewater could be considered as non toxic according to the phytotoxicity test since the germination index of Lepidium sativum ranged between 57 and 95%. The treatment provided satisfactory results and presents a feasible technology for the treatment of hydrocarbon-rich wastewater from petrochemical industries and petroleum refineries.

  18. Solutions for the disposal of industrial and rain wastewater of transport enterprises in Moscow

    Directory of Open Access Journals (Sweden)

    Varyushina Galina

    2018-01-01

    Full Text Available The article gives results of the surveys water management systems, auto repair companies, bus compamies, taxis, fleets of trucks, production and technical enterprises. Studied technological processes of primary production: cleaning engines, flushing of radiators and parts of batteries, testing of fuel tanks, cleaning of parts and units, exterior washing and painting of motor vehicles. There were carried out field examinations of local industrial wastewater treatment facilities industrial wastewater and onsite construction runoff, the laboratory-production work to identify quantitative and qualitative indicators of the incoming and treated effluents, including petroleum products, suspended matter, salinity, synthetic surfactants, heavy metals etc. Proposed sustainable solutions for the improvement of the work of treatment facilities of rain sewage by mechanical and physical and chemical methods, including horizontal sand catchers, septic tanks – oil separator, a cascade of pressure filters with granular mineral over-loading and high-performance sorption materials, the effectiveness of treatment meets the requirements of water for its re-use for technical needs, and discharge to water bodies.

  19. Fungal treatment of humic-rich industrial wastewater : application of white rot fungi in remediation of food-processing wastewater

    NARCIS (Netherlands)

    Zahmatkesh, M.; Spanjers, H.L.F.M.; van Lier, J.B.

    2017-01-01

    This paper presents the results of fungal treatment of a real industrial wastewater (WW), providing insight into the main mechanisms involved and clarifying some ambiguities and uncertainties in the previous reports. In this regard, the mycoremediation potentials of four strains of white rot

  20. A study on the treatment of industrial wastewater containing heavy metals

    International Nuclear Information System (INIS)

    Yoon, Myung Hwan; Chang, In Soon; Park, Jang Jin; Lee, Yoon Hwan; Shin, Jin Myung

    1994-08-01

    In order to practically use the acornic acid process for treating heavy metal contained wastewater, the pilot plant of 2.4 ton (wastewater)/day capacity was designed, constructed and operated. An electroplating wastewater originated from a company was treated with NaOH, acornic acid (60 ppm) and salt (1000 ppm) in this pilot plant. The COD, Cr, Fe and Zn cocentrations of treated water were 123, 0.08, 0.05 and 0.08 ppm, respectively. These values were all satisfied with the legal effluent limits. (Author)

  1. Anaerobic treatment of wastewater from the household and personal products industry in a hybrid bioreactor

    Directory of Open Access Journals (Sweden)

    D. J. Araujo

    2008-09-01

    Full Text Available The anaerobic treatment of wastewater from the household and personal products industry was studied using a 16.3 L hybrid reactor (UASB and biofilter. The top of the UASB reactor was filled with coconut shells to act as the support material for the biofilter. The wastewater was characterized in terms of pH (1.0 - 12.0, COD (1,000 - 5,000 mg/L, BOD5 (700 - 1,500 mg/L, chloride (55 - 850 mg/L, ammonia nitrogen (0.4 - 0.9 mg/L, total Kjeldahl nitrogen (22.1 - 34.0 mg/L, phosphorus (2.0 - 2.5 mg/L, anionic surfactants (100 - 600 mg/L, turbidity (115 - 300 NTU and total suspended solids (450 - 1,440 mg/L. The bioreactor was operated continuously for 120 days at room temperature (26 ± 5ºC with hydraulic retention times of 50, 40 and 60 h. COD and BOD removals and biogas production were evaluated in order to analyze process efficiency. The average removal efficiencies for COD (77%, 72% and 80% and BOD5 (approximately 90% were obtained with HRTs of 50, 40 and 60 h, respectively. The average specific biogas production was 0.32 L/g COD (at standard temperature and pressure for the three experimental runs. These data indicate good reactor efficiency and suggest the possibility of using this system to treat wastewater generated by the household and personal products industry.

  2. A national discharge load of perfluoroalkyl acids derived from industrial wastewater treatment plants in Korea.

    Science.gov (United States)

    Kim, Hee-Young; Seok, Hyun-Woo; Kwon, Hye-Ok; Choi, Sung-Deuk; Seok, Kwang-Seol; Oh, Jeong Eun

    2016-09-01

    Levels of 11 perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS), were measured in wastewater (influent and effluent) and sludge samples collected from 25 industrial wastewater treatment plants (I-WWTPs) in five industrial sectors (chemicals, electronics, metals, paper, and textiles) in South Korea. The highest ∑11PFAAs concentrations were detected in the influent and effluent from the paper (median: 411ng/L) and textile (median: 106ng/L) industries, and PFOA and PFOS were the predominant PFAAs (49-66%) in wastewater. Exceptionally high levels of PFAAs were detected in the sludge associated with the electronics (median: 91.0ng/g) and chemical (median: 81.5ng/g) industries with PFOS being the predominant PFAA. The discharge loads of 11 PFAAs from I-WWTP were calculated that total discharge loads for the five industries were 0.146ton/yr. The textile industry had the highest discharge load with 0.055ton/yr (PFOA: 0.039ton/yr, PFOS: 0.010ton/yr). Municipal wastewater contributed more to the overall discharge of PFAAs (0.489ton/yr) due to the very small industrial wastewater discharge compared to municipal wastewater discharge, but the contribution of PFAAs from I-WWTPs cannot be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Bacterial ecology of abattoir wastewater treated by an anaerobic digestor.

    Science.gov (United States)

    Jabari, Linda; Gannoun, Hana; Khelifi, Eltaief; Cayol, Jean-Luc; Godon, Jean-Jacques; Hamdi, Moktar; Fardeau, Marie-Laure

    2016-01-01

    Wastewater from an anaerobic treatment plant at a slaughterhouse was analysed to determine the bacterial biodiversity present. Molecular analysis of the anaerobic sludge obtained from the treatment plant showed significant diversity, as 27 different phyla were identified. Firmicutes, Proteobacteria, Bacteroidetes, Thermotogae, Euryarchaeota (methanogens), and msbl6 (candidate division) were the dominant phyla of the anaerobic treatment plant and represented 21.7%, 18.5%, 11.5%, 9.4%, 8.9%, and 8.8% of the total bacteria identified, respectively. The dominant bacteria isolated were Clostridium, Bacteroides, Desulfobulbus, Desulfomicrobium, Desulfovibrio and Desulfotomaculum. Our results revealed the presence of new species, genera and families of microorganisms. The most interesting strains were characterised. Three new bacteria involved in anaerobic digestion of abattoir wastewater were published. Copyright © 2015 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  4. Bacterial ecology of abattoir wastewater treated by an anaerobic digestor

    Directory of Open Access Journals (Sweden)

    Linda Jabari

    2016-03-01

    Full Text Available Abstract Wastewater from an anaerobic treatment plant at a slaughterhouse was analysed to determine the bacterial biodiversity present. Molecular analysis of the anaerobic sludge obtained from the treatment plant showed significant diversity, as 27 different phyla were identified. Firmicutes, Proteobacteria, Bacteroidetes, Thermotogae, Euryarchaeota (methanogens, and msbl6 (candidate division were the dominant phyla of the anaerobic treatment plant and represented 21.7%, 18.5%, 11.5%, 9.4%, 8.9%, and 8.8% of the total bacteria identified, respectively. The dominant bacteria isolated were Clostridium, Bacteroides, Desulfobulbus, Desulfomicrobium, Desulfovibrio and Desulfotomaculum. Our results revealed the presence of new species, genera and families of microorganisms. The most interesting strains were characterised. Three new bacteria involved in anaerobic digestion of abattoir wastewater were published.

  5. Effect of industrial waste products on phosphorus mobilisation and biomass production in abattoir wastewater irrigated soil.

    Science.gov (United States)

    Seshadri, Balaji; Kunhikrishnan, Anitha; Bolan, Nanthi; Naidu, Ravi

    2014-09-01

    This study evaluated the effect of alkaline industrial by-products such as flyash (FA) and redmud (RM) on phosphorus (P) mobilisation in abattoir wastewater irrigated soils, using incubation, leaching and plant growth (Napier grass [Pennisetum purpureum]) experiments. The soil outside the wastewater irrigated area was also collected and treated with inorganic (KH2PO4 [PP]) and organic (poultry manure [PM]) P treatments, to study the effect of FA and RM on P mobilisation using plant growth experiment. Among the amendments, FA showed the highest increase in Olsen P, oxalic acid content and phosphatase activity. The highest increase in Olsen P for PM treated non-irrigated soils showed the ability of FA and RM in mobilising organic P better than inorganic P (PP). There was over 85 % increase in oxalic acid content in the plant growth soils compared to the incubated soil, showing the effect of Napier grass in the exudation of oxalic acid. Both amendments (FA and RM) showed an increase in phosphatase activity at over 90 % at the end of the 5-week incubation period. The leaching experiment indicated a decrease in water soluble P thereby ensuring the role of FA and RM in minimising P loss to water bodies. FA and RM showed an increase in plant biomass for all treatments, where FA amended soil showed the highest increase as evident from FA's effect on Olsen P. Therefore, the use of FA and RM mobilised P in abattoir wastewater irrigated soils and increased biomass production of Napier grass plants through root exudation of oxalic acid.

  6. Opportunities for woody crop production using treated wastewater in Egypt

    Science.gov (United States)

    Ronald S. Jr. Zalesny; Steven R. Evett; Nabil F. Kandil; Chris Soriano; John A. Stanturf

    2009-01-01

    The Nile River provides nearly 97% of Egypt’s freshwater supply. Egypt's share of Nile waters is allocated according to international treaty obligations and is fixed at 55.5 billion cubic meters annually. As a result, Egypt will not be able to meet increasing water demand using freshwater from the Nile and has been developing wastewater reuse strategies to meet...

  7. Opportunities for woody crop production using treated wastewater in Egypt

    Science.gov (United States)

    R.S. Zalesny; S.R.  Evett; N.F. Kandil; C.  Soriano; John Stanturf

    2011-01-01

    The Nile River provides nearly 97% of Egypt’s freshwater supply. Egypt’s share of Nile waters is fixed at 55.5 billion cubic meters annually. As a result, Egypt will not be able to meet increasing water demand using freshwater from the Nile and has been developing non-conventional wastewater reuse strategies to meet future demands. The USAID Mission in Cairo began...

  8. Treatment of wastewater from rubber industry in Malaysia

    African Journals Online (AJOL)

    GREGORY

    2010-09-20

    Sep 20, 2010 ... remove over 95% biological oxygen demand (BOD) from rubber wastewater ... reduction system. (purple non- sulphur photosynthetic bacteria). Optimum growth in latex rubber sheet wastewater with 0.50% ammonium sulphate and 1 mg/l ... and energy costs of surface aerator, all of these factories had ...

  9. Construction and Operation Costs of Wastewater Treatment and Implications for the Paper Industry in China.

    Science.gov (United States)

    Niu, Kunyu; Wu, Jian; Yu, Fang; Guo, Jingli

    2016-11-15

    This paper aims to develop a construction and operation cost model of wastewater treatment for the paper industry in China and explores the main factors that determine these costs. Previous models mainly involved factors relating to the treatment scale and efficiency of treatment facilities for deriving the cost function. We considered the factors more comprehensively by adding a regional variable to represent the economic development level, a corporate ownership factor to represent the plant characteristics, a subsector variable to capture pollutant characteristics, and a detailed-classification technology variable. We applied a unique data set from a national pollution source census for the model simulation. The major findings include the following: (1) Wastewater treatment costs in the paper industry are determined by scale, technology, degree of treatment, ownership, and regional factors; (2) Wastewater treatment costs show a large decreasing scale effect; (3) The current level of pollutant discharge fees is far lower than the marginal treatment costs for meeting the wastewater discharge standard. Key implications are as follows: (1) Cost characteristics and impact factors should be fully recognized when planning or making policies relating to wastewater treatment projects or technology development; (2) There is potential to reduce treatment costs by centralizing wastewater treatment via industrial parks; (3) Wastewater discharge fee rates should be increased; (4) Energy efficient technology should become the future focus of wastewater treatment.

  10. Industrial wastewater as raw material for exopolysaccharide production by Rhizobium leguminosarum.

    Science.gov (United States)

    Sellami, Mohamed; Oszako, Tomasz; Miled, Nabil; Ben Rebah, Faouzi

    2015-06-01

    The objective of this study was to evaluate the exopolysaccharide (EPS) production by Rhizobium leguminosarum cultivated in wastewater generated by oil companies (WWOC1 and WWOC2) and fish processing industry (WWFP). The results obtained in Erlenmeyer flasks indicated that the rhizobial strain grew well in industrial wastewater. Generally, wastewater composition affected the growth and the EPS production. WWFP allowed good bacterial growth similar to that obtained with the standard medium (YMB). During growth, various quantities of EPS were produced and yields varied depending on the media. Growing in YMB, EPS production did not exceed 9.7 g/L obtained after 72 h of growth. In wastewater, the maximum EPS value reached 11.1 g/L obtained with the fish processing wastewater, after 72 h of growth. The use of a mixture of the oil company wastewater (WWOC2) and the fish processing wastewater (WWFP) as culture medium affected not only the rhizobial strain growth, but also EPS production. The highest EPS (42.4 g/L, after 96 h of culture) was obtained using a ratio of WWFP and WWOC2 of 50:50 (v:v). Therefore, this work shows the ability of Rhizobium leguminosarum, growing in industrial wastewater as new economic medium, to produce EPS. This biopolymer could be applied in enormous biotechnological areas.

  11. Effects of reactive filters based on modified zeolite in dairy industry wastewater treatment process

    OpenAIRE

    Kolaković, Srđan; Stefanović, Dragoslav; Milićević, Dragan; Trajković, Slaviša; Milenković, Slobodan; Kolaković, Slobodan S.; Anđelković, Ljiljana

    2013-01-01

    Application of adsorbents based on organo-zeolites has certain advantages over conventional methods applied in food industry wastewater treatment process. The case study presented in this paper examines the possibilities and effects of treatment of dairy industry wastewater by using adsorbents based on organo-zeolites. The obtained results indicate favorable filtration properties of organo-zeolite, their high level of adsorption of organic matter and nitrat...

  12. Biosorption of hexavalent chromium in a tannery industry wastewater using fungi species

    OpenAIRE

    D. Sivakumar

    2016-01-01

    The isolated fungi species of different kinds from chromium contaminated soil sites located in Nagalkeni, Chennai were used for reducing chromium(VI) in a tannery industry wastewater of Nagalkeni, Chennai.  The experiments were conducted to know biosorption potential of isolated fungi species for removing chromium(VI) in a tannery industry wastewater against the different pH, fungi biomass and chromium(VI) concentration (dilution ratio).  The results of this study indicated that the order of ...

  13. Micro-electrolysis technology for industrial wastewater treatment.

    Science.gov (United States)

    Jin, Yi-Zhong; Zhang, Yue-Feng; Li, Wei

    2003-05-01

    Experiments were conducted to study the role of micro-electrolysis in removing chromaticity and COD and improving the biodegradability of wastewater from pharmaceutical, dye-printing and papermaking plants. Results showed that the use of micro-electrolysis technology could remove more than 90% of chromaticity and more than 50% of COD and greatly improved the biodegradability of pharmaceutical wastewater. Lower initial pH could be advantageous to the removal of chromaticity. A retention time of 30 minutes was recommended for the process design of micro-electrolysis. For the use of micro-electrolysis in treatment of dye-printing wastewater, the removal rates of both chromaticity and COD were increased from neutral condition to acid condition for disperse blue wastewater; more than 90% of chromaticity and more than 50% of COD could be removed in neutral condition for vital red wastewater.

  14. Process Integration Design Methods for Water Conservation and Wastewater Reduction in Industry

    DEFF Research Database (Denmark)

    Overcash, Michael; Russell, Dunn; Wenzel, Henrik

    2002-01-01

    This paper addresses operational techniques for applying mass integration design in industry with special focus on water conservation and wastewater reduction. This paper presents a design technique for any number of wastewater streams containing multiple contaminants. The technique comprises...... a single non-linear optimization program to minimize the wastewater discharged (or maximize the amount of recycled wastewater). This program is developed based on general water allocation principles and uses the transshipment model theory to allow the “shipment” of wastewater (referred to as “sources......” or “warehouses”) to process water users (referred to as “sinks”, “demands” or “customers”). A detailed case study of industrial significance, highlighting land treatment technology, is included to illustrate the proposed methodology and various process scenarios are evaluated within this case study...

  15. The functional and physiological status of Gammarus fossarum (Crustacea; Amphipoda) exposed to secondary treated wastewater.

    Science.gov (United States)

    Bundschuh, Mirco; Zubrod, Jochen P; Schulz, Ralf

    2011-01-01

    Climate change scenarios predict lower flow rates during summer that may lead to higher proportions of wastewater in small and medium sized streams. Moreover, micropollutants (e.g. pharmaceuticals and other contaminants) continuously enter aquatic environments via treated wastewater. However, there is a paucity of knowledge, whether extended exposure to secondary treated wastewater disrupts important ecosystem functions, e.g. leaf breakdown. Therefore, the amphipod shredder Gammarus fossarum was exposed to natural stream water (n=34) and secondary treated wastewater (n=32) for four weeks in a semi-static test system under laboratory conditions. G. fossarum exposed to wastewater showed significant reductions in feeding rate (25%), absolute consumption (35%), food assimilation (50%), dry weight (18%) and lipid content (22%). Thus, high proportions of wastewater in the stream flow may affect both the breakdown rates of leaf material and thus the availability of energy for the aquatic food web as well as the energy budget of G. fossarum. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. EFFECT OF STARCH ADDITION ON THE PERFORMANCE AND SLUDGE CHARACTERIZATION OF UASB PROCESS TREATING METHANOLIC WASTEWATER

    Science.gov (United States)

    Yan, Feng; Kobayashi, Takuro; Takahashi, Shintaro; Li, Yu-You; Omura, Tatsuo

    A mesophilic(35℃) UASB reactor treating synthetic wastewater containing methanol with addition of starch was continuously operated for over 430 days by changing the organic loading rate from 2.5 to 120kg-COD/m3.d. The microbial community structure of the granules was analyzed with the molecular tools and its metabolic characteristics were evaluated using specific methanogenic activity tests. The process was successfully operated with over 98% soluble COD removal efficiency at VLR 30kg-COD/m3.d for approximately 300 days, and granulation satisfactory proceeded. The results of cloning and fluorescence in situ hybridization analysis suggest that groups related the genus Methanomethylovorans and the genus Methanosaeta were predominant in the reactor although only the genus Methanomethylovorans was predominant in the reactor treating methanolic wastewater in the previous study. Abundance of the granules over 0.5 mm in diameter in the reactor treating methanolic wastewater with addition of starch was 3 times larger than that in the reactor treating methanolic wastewater. Specific methanogenic activity tests in this study indicate that the methanol-methane pathway and the methanol-H2/CO2-methane pathway were predominant, and however, there was a certain level of activity for acetate-methane pathway unlike the reactor treating methanolic wastewater. These results suggest addition of starch might be responsible for diversifying the microbial community and encouraging the granulation.

  17. A social choice-based methodology for treated wastewater reuse in urban and suburban areas.

    Science.gov (United States)

    Mahjouri, Najmeh; Pourmand, Ehsan

    2017-07-01

    Reusing treated wastewater for supplying water demands such as landscape and agricultural irrigation in urban and suburban areas has become a major water supply approach especially in regions struggling with water shortage. Due to limited available treated wastewater to satisfy all water demands, conflicts may arise in allocating treated wastewater to water users. Since there is usually more than one decision maker and more than one criterion to measure the impact of each water allocation scenario, effective tools are needed to combine individual preferences to reach a collective decision. In this paper, a new social choice (SC) method, which can consider some indifference thresholds for decision makers, is proposed for evaluating and ranking treated wastewater and urban runoff allocation scenarios to water users in urban and suburban areas. Some SC methods, namely plurality voting, Borda count, pairwise comparisons, Hare system, dictatorship, and approval voting, are applied for comparing and evaluating the results. Different scenarios are proposed for allocating treated wastewater and urban runoff to landscape irrigation, agricultural lands as well as artificial recharge of aquifer in the Tehran metropolitan Area, Iran. The main stakeholders rank the proposed scenarios based on their utilities using two different approaches. The proposed method suggests ranking of the scenarios based on the stakeholders' utilities and considering the scores they assigned to each scenario. Comparing the results of the proposed method with those of six different SC methods shows that the obtained ranks are mostly in compliance with the social welfare.

  18. Use of nanofiltration membrane technology for ceramic industry wastewater treatment

    Directory of Open Access Journals (Sweden)

    Moliner-Salvador, R.

    2012-04-01

    Full Text Available A study has been undertaken of an advanced wastewater treatment approach using polymer nanofiltration membranes, in an attempt to obtain water of sufficient quality to allow it to be reused in the same production process or, alternatively, to be discharged without any problems. The study has initially focused on the removal of organic matter (reduction of COD and the most representative ions present in the wastewater, such as Na+, Mg2+, Cl- y SO42-. In a first part of the study, with a view to optimising the experimental phase, a simulation has been performed of the nanofiltration process using the NanoFlux software. Among other things, the simulation allows the most suitable membranes to be selected as a function of the permeate flow rate and desired level of retention in the substances to be removed. The subsequent experimentation was carried out in a laboratory tangential filtration system that works with flat membranes. It was found that retention values of about 90% were obtained for the studied substances, with a good permeate flow rate, using low operating pressures. These results demonstrate the feasibility of the studied technology and its potential as a treatment for improving ceramic industry wastewater quality.

    Este estudio ha sido emprendido con el fin de acercar la nanofiltración a través de membranas poliméricas al tratamiento de las aguas residuales industriales de la industria cerámica, esperando obtener un agua con la suficiente calidad como para ser reutilizada en el propio proceso productivo o, alternativamente, poder verterla. El estudio se ha centrado en la eliminación de materia orgánica (reducción de D.Q.O y algunos iones presentes en las aguas residuales, tales como Na+, Mg2+, Cl- y SO42-. En primer lugar, se ha realizado una simulación del proceso de nanofiltración usando el software Nano

  19. Preparation of new conductive polymer nanocomposites for cadmium removal from industrial wastewaters

    International Nuclear Information System (INIS)

    Zoleikani, Leila; Issazadeh, Hossein; ZareNezhad, Bahman

    2015-01-01

    Different conductive polymer nanocomposites have been synthesized, characterized and tested, regarding the removal of cadmium from industrial wastewaters. The chemical structure and morphology are studied by FTIR spectroscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD). The cadmium removal performance, using the produced polypyrrole, polyaniline and polythiophene nanocomposites, are about 40.2 %, 59 % and 99.94 %, respectively, suggesting the superior performance of synthesized polythiophene conductive nanocomposite for cadmium removal from industrial wastewaters. It is shown that the Langmuir adsorption model can be used for accurate description of cadmium removal mechanism using different synthesized conductive nanocomposites. Keywords : wastewater, nanocomposite, polythiophene, cadmium removal, conductive polymer.

  20. Effects of reactive filters based on modified zeolite in dairy industry wastewater treatment process

    Directory of Open Access Journals (Sweden)

    Kolaković Srđan

    2013-01-01

    Full Text Available Application of adsorbents based on organo-zeolites has certain advantages over conventional methods applied in food industry wastewater treatment process. The case study presented in this paper examines the possibilities and effects of treatment of dairy industry wastewater by using adsorbents based on organo-zeolites. The obtained results indicate favorable filtration properties of organo-zeolite, their high level of adsorption of organic matter and nitrate nitrogen in the analyzed wastewater. This paper concludes with recommendations of optimal technical and technological parameters for the application of these filters in practice.

  1. Aerobic granulation in a sequencing batch reactor (SBR) for industrial wastewater treatment.

    Science.gov (United States)

    Inizan, M; Freval, A; Cigana, J; Meinhold, J

    2005-01-01

    Aerobic granulation seems to be an a attractive process for COD removal from industrial wastewater, characterised by a high content of soluble organic compounds. In order to evaluate the practical aspects of the process, comparative experimental tests are performed on synthetic and on industrial wastewater, originating from pharmaceutical industry. Two pilot plants are operated as sequencing batch bubble columns. Focus was put on the feasibility of the process for high COD removal and on its operational procedure. For both wastewaters, a rapid formation of aerobic granules is observed along with a high COD removal rate. Granule characteristics are quite similar with respect to the two types of wastewater. It seems that filamentous bacteria are part of the granule structure and that phosphorus precipitation can play an important role in granule formation. For both wastewaters similar removal performances for dissolved biodegradable COD are observed (> 95%). However, a relatively high concentration of suspended solids in the outlet deteriorates the performance with regard to total COD removal. Biomass detachment seems to play a non-negligible role in the current set-up. After a stable operational phase the variation of the pharmaceutical wastewater caused a destabilisation and loss of the granules, despite the control for balanced nutrient supply. The first results with real industrial wastewater demonstrate the feasibility of this innovative process. However, special attention has to be paid to the critical aspects such as granule stability as well as the economic competitiveness, which both will need further investigation and evaluation.

  2. Biosorption of hexavalent chromium in a tannery industry wastewater using fungi species

    International Nuclear Information System (INIS)

    Sivakumar, D.

    2016-01-01

    The isolated fungi species of different kinds from chromium contaminated soil sites located in Nagalkeni, Chennai were used for reducing chromium(VI) in a tannery industry wastewater of Nagalkeni, Chennai. The experiments were conducted to know biosorption potential of isolated fungi species for removing chromium(VI) in a tannery industry wastewater against the different p H, fungi biomass and chromium(VI) concentration (dilution ratio). The results of this study indicated that the order of maximum removal of chromium(VI) by an isolated fungi species at an optimum pH of 3, fungi biomass of 4g and an initial chromium(VI) concentration of 18.125 mg/L (dilution ratio 4) is A. niger > A. flavus > A. fumigatus > A. nidulans > A. heteromorphus > A. foetidus > A. viridinutans. This study found that the maximum removal of chromium(VI) was achieved by Aspergillus niger (96.3 %) than other fungi species at chromium(VI) concentration of 18.125 mg/L in a tannery industry wastewater. The chromium removal from tannery industry wastewater was validated by checking chromium removal in an aqueous solution and by checking the removal efficiency of other parameters in a tannery industry wastewater using same isolated A. niger. Biosorption model was proposed to simulate the experimental condition for removing chromium(VI) in a tannery industry wastewater by all isolated fungi species. The R2 and x2 values of the proposed model predicted that the proposed biosorption model is very much useful for predicting the trend of reduction potential of chromium(VI) in a tannery industry wastewater by all isolated fungi species. This study suggested that one could select the type of fungi species, ion concentration level, selection of treatment period, quantity of biomass to be used, and p H level of the medium, to achieve the highest reduction of any toxic metals from any contaminated water, wastewater and soil environment.

  3. Performance of a UASB-digester system treating domestic wastewater.

    Science.gov (United States)

    Alvarez, J A; Armstrong, E; Presas, J; Gómez, M; Soto, M

    2004-10-01

    The anaerobic treatment of raw domestic wastewater by a novel technology consisting of an Up-flow Anaerobic Sludge Bed (UASB) reactor combined with a completely mixed digester for the stabilisation of the UASB sludge was assessed. A pilot-scale plant of the so-called UASB-Digester system was located at the municipal wastewater treatment facility of Santiago de Compostela (Northwest of Spain). The main aim of the Digester was to enhance the biodegradation of influent solids retained in the UASB reactor at low temperatures, then increasing its specific methanogenic activity. The sludge drawn from the middle zone of the UASB entered the upper zone of the Digester and then circulated from the bottom of the Digester to the UASB bottom. Circulating in an automated semi-continuous way, the flow of this sludge stream was selected in order to set a previously defined hydraulic retention time (HRT) (16-27 d) in the digester. The Digester temperature was set at an optimum value ranging from 25 to 35 degrees C. The steady state efficiency of the UASB system, at 6-8 h of HRT, 15-16 degrees C of temperature and 330-360 mg l(-1) of influent total chemical oxygen demand (TCOD) was 79% of total suspended solids (TSS) removal, 52% of TCOD removal and 60% of biological oxygen demand (BOD5) removal. The hydrolysis of retained solids reached 85%, while excess sludge generation was only 7% of influent TCOD. A stable anaerobic (pre)treatment of diluted domestic wastewater was reached as the sludge concentration in the reactor remained mainly constant and the specific methanogenic activity showed a slight increase.

  4. Construction and operation costs of constructed wetlands treating wastewater.

    Science.gov (United States)

    Gkika, Dimitra; Gikas, Georgios D; Tsihrintzis, Vassilios A

    2014-01-01

    Design data from nine constructed wetlands (CW) facilities of various capacities (population equivalent (PE)) are used to estimate construction and operation costs, and then to derive empirical equations relating the required facility land area and the construction cost to PE. In addition, comparisons between the costs of CW facilities based on various alternative construction materials, i.e., reinforced concrete and earth structures (covered with either high density polyethylene or clay), are presented in relation to the required area. The results show that earth structures are economically advantageous. The derived equations can be used for providing a preliminary cost estimate of CW facilities for domestic wastewater treatment.

  5. COD biological removal and biogas production in anaerobic reactor treating cassava wastewater industry; Remocao biologica de DQO e producao de biogas em reator anaerobio tratando efluente de fecularia de madioca

    Energy Technology Data Exchange (ETDEWEB)

    Watthier, Elisangela [Universidade Estadual do Oeste do Parana (UNIOESTE), Cascavel, PR (Brazil). Curso de Mestrado em Engenharia Agricola; Andreani, Cristiane Lurdes [Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq), Brasilia, DF (Brazil); Gomes, Simone Damasceno [Universidade Estadual do Oeste do Parana (PGEAGRI/UNIOESTE), Cascavel, PR (Brazil). Programa de Pos-Graduacao em Engenharia Agricola; Moreschi, Roberson; Rufino, Mauricio de Oliveira [Universidade Estadual do Oeste do Parana (UNIOESTE), Cascavel, PR (Brazil). Curso de Engenharia Agricola

    2010-07-01

    The effluent from the cassava industry cause damage to the environment if released without treatment. One alternative is the implementation of anaerobic reactors, which also add value through the production of biogas. The support means increases the contact surface of micro-organisms and enhance their setting. The purpose of this study was to evaluate the reduction of organic matter (DQO) and biogas production in a reactor of PVC with 90 cm long and 15 cm in diameter, through support rings of bamboo, 10 cm in length and diameter ranged from 1.7 to 2.5 cm, with a volume of 6 L. The organic loading used were 4,357, 4,708, 5,601 and 6,126 g DQO.L-1.day-1, corresponding to hydraulic retention time (TRH) of 3,5, 2,8, 3,25 and 2,7 days, respectively. It was observed that with the increase of organic load was increased production of biogas, the largest observed for a load of 6.126 g DQO.L-1.day-1 with an average of 9.146 L.day-1. Regarding the removal of organic matter were achieved values of 98.35, 99.09, 99.33 and 98.55% respectively for each load applied, with the highest efficiency observed in charge of 5.601 g COD. L-1. day-1, but without significant differences. (author)

  6. Evaluation of membrane bioreactor for advanced treatment of industrial wastewater and reverse osmosis pretreatment

    Science.gov (United States)

    2013-01-01

    The evaluation of a membrane bioreactor (MBR) for pretreatment of reverse osmosis (RO) in order to reuse and reclamation of industrial town wastewater treatment plant was investigated in this study. Performance of MBR effluent through water quality in term of parameters such as chemical oxygen demand (COD), total suspended solids (TSS), total nitrogen (TN) and total coliform (TC) were measured. Also Silt density index (SDI) was used as indicator for RO feed water. The results of this study demonstrated that MBR produce a high quality permeate water. Approximately 75%, 98%, 74% and 99.9% removal of COD, TSS, TN and TC were recorded, respectively. Also SDI of the permeate effluent from membrane was below 3 for most of the times. It means that pilot yield a high quality treated effluent from the membrane module which can be used as RO feed water. PMID:24355199

  7. APPLICATION OF CONSTRUCTED WETLANDS FOR TREATMENT OF WASTEWATER FROM FRUIT AND VEGETABLE INDUSTRY

    Directory of Open Access Journals (Sweden)

    Monika Puchlik

    2016-01-01

    Full Text Available About 2000 plants are involved in fruit and vegetable processing in Poland, they are mostly located in non-urbanized areas and without any access to sewerage and sewage treatment facilities. In 2014, they produced more than 10 hm3 of wastewater requiring treatment, which was discharged directly into surface waters or into the ground. The aim of the study was to evaluate the efficiency of the constructed wetland for treating the sewage from fruit and vegetable industry. The analyzed constructed wetland with vertical flow reveled a reduction in the value of BOD5 to 68.2%, and CODCr to 79.3%. The model was characterized by 60.2% efficiency of total phosphorus removal.

  8. Energy efficient aeration of wastewaters from the pulp and paper industry.

    Science.gov (United States)

    Sandberg, M

    2010-01-01

    More than 50% of the electrical power needed to treat pulp and paper industry effluents is used for aeration in biological treatment stages. A large share of the oxygen that passes through the wastewater is not consumed and will be found in the off-gas. Energy can be saved by aerating under conditions where the oxygen transfer is most efficient, for example at low concentrations of dissolved oxygen Consider the sludge as an energy source; electricity can be saved by avoiding sludge reduction through prolonged aeration. High oxygen transfer efficiency can be retained by using the oxygen consumption of biosolids. Quantified savings in the form of needed volumes of air while still achieving sufficient COD reduction are presented. The tests have been made in a bubble column with pulp mill process water and sludge from a biological treatment plant. These were supplemented with case studies at three pulp and paper mills.

  9. Cyanide removal from industrial wastewater by cross-flow nanofiltration: transport modeling and economic evaluation.

    Science.gov (United States)

    Pal, Parimal; Bhakta, Pamela; Kumar, Ramesh

    2014-08-01

    A modeling and simulation study, along with an economic analysis, was carried out for the separation of cyanide from industrial wastewater using a flat sheet cross-flow nanofiltration membrane module. With the addition of a pre-microfiltration step, nanofiltration was carried out using real coke wastewater under different operating conditions. Under the optimum operating pressure of 13 bars and a pH of 10.0, a rate of more than 95% separation of cyanide was achieved. That model predictions agreed very well with the experimental findings, as is evident in the Willmott d-index value (> 0.95) and relative error (industrial wastewater instead of a synthetic solution, and an economic analysis was also done, considering the capacity of a running coking plant. The findings are likely to be very useful in the scale-up and design of industrial plants for the treatment of cyanide-bearing wastewater.

  10. Briquette fuel production from wastewater sludge of beer industry and biodiesel production wastes

    Science.gov (United States)

    Nusong, P.; Puajindanetr, S.

    2018-04-01

    The production of industrial wastes is increasing each year. Current methods of waste disposal are severely impacting the environment. Utilization of industrial wastes as an alternative material for fuel is gaining interest due to its environmental friendliness. Thus, the objective of this research was to study the optimum condition for fuel briquettes produced from wastewater sludge of the beer industry and biodiesel production wastes. This research is divided into two parts. Part I will study the effects of carbonization of brewery wastewater sludge for high fixed carbon. Part II will study the ratio between brewery wastewater sludge and bleaching earth for its high heating value. The results show that the maximum fixed carbon of 10.01% by weight was obtained at a temperature of 350 °C for 30 minutes. The appropriate ratio of brewery wastewater sludge and bleaching earth by weight was 95:5. This condition provided the highest heating value of approximately 3548.10 kcal/kg.

  11. The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality

    International Nuclear Information System (INIS)

    Ben Rouina, B.; Bedbabis, S.; Ben Ahmed, C.; Boukhris, M.

    2009-01-01

    Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

  12. Irrigating okra with secondary treated municipal wastewater: Observations regarding plant growth and soil characteristics.

    Science.gov (United States)

    Kumar, Vinod; Chopra, A K; Srivastava, Sachin; Singh, Jogendra; Thakur, Roushan Kumar

    2017-05-04

    The present study was carried out to probe the agronomic response of hybrid cultivar of okra (Hibiscus esculentus L. var. JK 7315) grown in secondary treated municipal wastewater irrigated soil with field investigations. The concentrations of the municipal wastewater viz., 10%, 20%, 40%, 60%, 80%, and 100% along with the control (groundwater) were used for the irrigation of the H. esculentus. The study revealed that the concentrations of the municipal wastewater showed significant (p fertigation in comparison to groundwater in both the seasons. The maximum agronomic performance of the H. esculentus was recorded with 60% concentration of the municipal wastewater in both the seasons. The contamination factor of heavy metals varied in the H. esculentus plants and soils. In the H. esculentus plants, following fertigation with municipal wastewater, the contamination factor of manganese was the highest, while that of chromium was the lowest. Intermediate contamination factor were observed for zinc, copper, and cadmium. Therefore, secondary treated municipal wastewater can be used as an agro-fertigant after appropriate dilution (up to 60%) to achieve the maximum yield of the H. esculentus.

  13. Continuous treatment of coloured industry wastewater using immobilized Phanerochaete chrysosporium in a rotating biological contactor reactor.

    Science.gov (United States)

    Pakshirajan, Kannan; Kheria, Sumeet

    2012-06-30

    Coloured industry wastewaters often contain dyes and other toxic ingredients, and, therefore, pose serious threat to the receiving environment. Among the available methods the eco-friendly biological method has gained maximum attention due to its many advantages over the traditional methods. In the present study, continuous biological treatment of coloured wastewater from a textile dyeing industry was investigated using the white rot fungus Phanerochaete chrysosporium in a rotating biological contactor (RBC) reactor. The raw wastewater was diluted with an equal volume of either distilled water or media containing glucose at varying concentrations to study its effect on the decolourization process. Results revealed that the wastewater could be decolourized to an extent of more than 64% when diluted with media containing glucose; and, a maximum decolourization efficiency of 83% was obtained with 10 g/l glucose concentration. COD removal efficiencies were also found to be consistent with the decolourization efficiencies of the wastewaters. Further, the results were correlated with the enzyme activities of manganese peroxidase (MnP) and lignin peroxidase (LiP) by the fungus, which were found to play some significant role in decolourization of the wastewater. Results of replacing the costly carbon source glucose in the decolourization media with the more cheap molasses, however, revealed very high COD removal efficiency, but low decolourization efficiency of the industry wastewater. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. CWPO of 4-CP and industrial wastewater with Al-Fe pillared clays.

    Science.gov (United States)

    Molina, C B; Zazo, J A; Casas, J A; Rodriguez, J J

    2010-01-01

    Catalysts based on pillared clays with Al-Fe have been synthesised from a commercial bentonite and tested for catalytic wet peroxide oxidation (CWPO) of aqueous 4-Chlorophenol (4-CP) solution and industrial wastewater from cosmetics manufacture. The effect of the synthesis procedure, the iron load and reaction temperature on the catalytic activity was studied using 4-CP as target compound. A lower temperature in the preparation of the pillaring solution, as well as a higher Fe load, gave rise to a higher catalytic activity, but also a higher leaching of the active phase. The best catalyst, in terms of catalytic activity, was also tested for treating cosmetic wastewater by CWPO. Experiments were carried out at 90 degrees C and atmospheric pressure and the influence of Fe load, catalyst concentration and H(2)O(2)/COD ratio (between 0.5 and 2 times the stoichiometric ratio) were analysed. Higher values of these parameters favour COD reduction. The Fe leaching in all cases was lower than 1.2 mg/L, indicating that these catalysts have a high stability under these experimental conditions.

  15. REMOVAL OF REACTIVE DYES FROM WASTEWATER OF TEXTILE INDUSTRIES BY USING ENVIRONMENTAL FRIENDLY ADSORBENTS

    Directory of Open Access Journals (Sweden)

    ALAM Md Shamim

    2016-05-01

    Full Text Available This paper is aimed at developing a method to treat wastewater by using inexpensive adsorbents. Textile industries produce wastewater, otherwise known as effluent, as a bi-product of their production. The effluent contains several pollutants. Among the various stages of textile production, the operations in the dyeing plant, which include pre-treatments, dyeing, printing and finishing, produce the most pollution. The textile dyeing wastes contain unused or partially used organic compounds, and high level of different pollutants. They are often of strong color and may also be of high temperature. When disposed into water bodies or onto land these effluents will result in the deterioration of ecology and damage to aquatic life. Furthermore they may cause damage to fisheries and economic loss to fishermen and farmer, there may be impacts on human health which can be removed with the help of an effluent treatment plant (ETP. The “clean” water can then be safely discharged into the environment and ultimately save our environment from pollution. In this study, rice husk and cotton dust were used as an adsorbent. In this research work waste water was characterized with this useless adsorbents. The parameters which were tested in this study are DO, BOD, COD, TS, TDS and TSS. The results showed that the selected bio adsorbents have good potential for removal of reactive dyes from textile effluent.

  16. Genotoxicity assessments of alluvial soil irrigated with wastewater from a pesticide manufacturing industry.

    Science.gov (United States)

    Anjum, Reshma; Krakat, Niclas

    2015-10-01

    In this study, organochlorine pesticides (OCP) and heavy metals were analyzed from wastewater- and groundwater- irrigated soils (control samples) by gas chromatography (GC) and atomic absorption spectrophotometry (AAS), respectively. Gas chromatographic analysis revealed the presence of high concentration of pesticides in soil irrigated with wastewater (WWS). These concentrations were far above the maximum residue permissible limits indicating that alluvial soils have high binding capacity of OCP. AAS analyses revealed higher concentration of heavy metals in WWS as compared to groundwater (GWS). Also, the DNA repair (SOS)-defective Escherichia coli K-12 mutant assay and the bacteriophage lambda system were employed to estimate the genotoxicity of soils. Therefore, soil samples were extracted by hexane, acetonitrile, methanol, chloroform, and acetone. Both bioassays revealed that hexane-extracted soils from WWS were most genotoxic. A maximum survival of 15.2% and decline of colony-forming units (CFUs) was observed in polA mutants of DNA repair-defective E. coli K-12 strains when hexane was used as solvent. However, the damage of polA (-) mutants triggered by acetonitrile, methanol, chloroform, and acetone extracts was 80.0, 69.8, 65.0, and 60.7%, respectively. These results were also confirmed by the bacteriophage λ test system as hexane extracts of WWS exhibited a maximum decline of plaque-forming units for lexA mutants of E. coli K-12 pointing to an elevated genotoxic potential. The lowest survival was observed for lexA (12%) treated with hexane extracts while the percentage of survival was 25, 49.2, 55, and 78% with acetonitrile, methanol, chloroform, and acetone, respectively, after 6 h of treatment. Thus, our results suggest that agricultural soils irrigated with wastewater from pesticide industries have a notably high genotoxic potential.

  17. A Study on Membrane Bioreactor for Water Reuse from the Effluent of Industrial Town Wastewater Treatment Plant

    Directory of Open Access Journals (Sweden)

    Majid Hosseinzadeh

    2014-03-01

    Full Text Available Background: Considering the toxic effects of heavy metals and microbial pathogens in industrial wastewaters, it is necessary to treat metal and microbial contaminated wastewater prior to disposal in the environment. The purpose of this study is to assess the removal of heavy metals pollution and microbial contamination from a mixture of municipal and industrial wastewater using membrane bioreactor. Methods: A pilot study with a continuous stream was conducted using a 32-L-activated sludge with a flat sheet membrane. Actual wastewater from industrial wastewater treatment plant was used in this study. Membrane bioreactor was operated with a constant flow rate of 4 L/hr and chemical oxygen demand, suspended solids concentration, six heavy metals concentration, and total coliform amounts were recorded during the operation. Results: High COD, suspended solids, heavy metals, and microbial contamination removal was measured during the experiment. The average removal percentages obtained by the MBR system were 81% for Al, 53% for Fe, 94% for Pb, 91% for Cu, 59% for Ni, and 49% for Cr which indicated the presence of Cu, Ni, and Cr in both soluble and particle forms in mixed liquor while Al, Fe, and Pb were mainly in particulate form. Also, coliforms in the majority of the samples were <140 MPN/100mL that showed that more than 99.9% of total coliform was removed in MBR effluent. Conclusion: The Membrane Biological Reactor (MBR showed a good performance to remove heavy metals and microbial matters as well as COD and suspended solids. The effluent quality was suitable for reusing purposes.

  18. Use of hydroponics culture to assess nutrient supply by treated wastewater.

    Science.gov (United States)

    Adrover, Maria; Moyà, Gabriel; Vadell, Jaume

    2013-09-30

    The use of treated wastewater for irrigation is increasing, especially in those areas where water resources are limited. Treated wastewaters contain nutrients that are useful for plant growth and help to reduce fertilizers needs. Nutrient content of these waters depends on the treatment system. Nutrient supply by a treated wastewater from a conventional treatment plant (CWW) and a lagooned wastewater from the campus of the University of Balearic Islands (LWW) was tested in an experiment in hydroponics conditions. Half-strength Hoagland nutrient solution (HNS) was used as a control. Barley (Hordeum vulgare L.) seedlings were grown in 4 L containers filled with the three types of water. Four weeks after planting, barley was harvested and root and shoot biomass was measured. N, P, K, Ca, Mg, Na and Fe contents were determined in both tissues and heavy metal concentrations were analysed in shoots. N, P and K concentrations were lower in LWW than in CWW, while HNS had the highest nutrient concentration. Dry weight barley production was reduced in CWW and LWW treatments to 49% and 17%, respectively, comparing to HNS. However, to a lesser extent, reduction was found in shoot and root N content. Treated wastewater increased Na content in shoots and roots of barley and Ca and Cr content in shoots. However, heavy metals content was lower than toxic levels in all the cases. Although treated wastewater is an interesting water resource, additional fertilization is needed to maintain a high productivity in barley seedlings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Wastewater Treatment from Batik Industries Using TiO2 Nanoparticles

    Science.gov (United States)

    Arifan, Fahmi; Nugraheni, FS; Rama Devara, Hafiz; Lianandya, Niken Elsa

    2018-02-01

    Batik is cultural patterned fabric, and the this industries produce wastewater that can pollute the aquatic environment. Besides dyes, batik wastewater also contains synthetic compounds that are hard degraded, such as heavy metals, suspended solids, or organic compounds. In this study, photocatalitic membrane TiO2 coated plastic sheets have been used to degrade batik wastewater under solar exposure. A total of 8 pieces of catalyst sheets are added on 1000 ml of the waste, and managed to degrade 50.41% of the initial concentration during 5-days irradiation. In this study, several parameters of the water quality such as chemical oxygen demand (COD), biological oxygen demand (BOD), and total suspensed solids (TSS) of the wastewater were observed to be decreasing during photodegradation process. The catalyst sheet also is stable to be used repeatedly in wastewater treatment.

  20. Preparation, Characterization of Coal Ash Adsorbent and Orthogonal Experimental Rsearch on Treating Printing and Dyeing Wastewater

    Science.gov (United States)

    Wang, Qingyu; He, Lingfeng; Shi, Liang; Chen, Xiaogang; Chen, Xin; Xu, Zizhen; Zhang, Yongli

    2018-03-01

    Using high temperature activated sodium flying ash and carboxymethyl chitosan as raw material to prepare carboxymethylchitosan wrapping fly-ash adsorbent (CWF), combined with iron-carbon micro-electrolysis treatment of simulated and actual printing and dyeing wastewater. The conditions for obtaining are from the literature: the best condition for CWF to treat simulated printing and dyeing wastewater pretreated with iron-carbon micro-electrolysis is that the mixing time is 10min, the resting time is 30 min, pH=6, and the adsorbent dosage is 0.75 g/L. The results showed that COD removal efficiency and decoloration rate were above 97 %, and turbidity removal rate was over 90 %. The optimum dyeing conditions were used to treat the dyeing wastewater. The decolorization rate was 97.30 %, the removal efficiency of COD was 92.44 %, and the turbidity removal rate was 90.37 %.

  1. COD fractions changes in the SBR-type reactor treating municipal wastewater with controlled percentage of dairy sewage

    Science.gov (United States)

    Struk-Sokołowska, Joanna; Rodziewicz, Joanna

    2017-11-01

    The aim of study was to investigate the influence of percentage of dairy wastewater in the municipal wastewater on the changes of COD fractions during the cycle of SBR-type reactor. The scope of the research included physicochemical analyses of municipal wastewater without dairy wastewater, dairy wastewater, mixture of municipal and dairy wastewater as well as treated sewage. Both the concentrations and the proportions between COD fractions changed in the SBR cycle. In raw municipal and dairy wastewater - XS, insoluble hardly bio-degradable fraction of COD dominated (49.6 and 64.5% respectively). In treated wastewater SI, COD for dissolved compounds that are not biologically decomposed (inert) (from 62.1 to 74.6%) dominated, while XS fraction was from 19.1 to 24.4%. The consumption rate of organic compounds depended on the type of COD fraction, SBR cycle phase and the percentage of dairy wastewater. The highest rates of organic compounds consumption were noted in the phase of mixing. In the case of fraction SI, no differences in concentration in the SBR cycle time, were found. Concentration of COD in treated wastewater was from 34.8 to 58.9 mgO2·L-1 (efficiency wastewater treatment from 96.0 to 98.6%).

  2. Utilization of Paper Sludge Wastes for Treatment of Wastewater from Food Processing Industries

    Directory of Open Access Journals (Sweden)

    Tohru Suzuki

    2012-12-01

    Full Text Available The food processing industries usually produced large amount of wastewater containing fine and small particles. It takes long time for complete settlement of the fine and small particles in the wastewater. The coagulation method appears to become one of the useful treatments. New inorganic coagulant named “Agoclean‒P” has been developed from paper sludge ash. The treatment by coagulation and flocculation were carried out for the wastewater from three different food processing industries namely soup, tofu, and natto. “Hi‒Biah‒System”, which is an in‒situ solidification system, was used for the continuous treatment of wastewater. The parameters for the water quality were pH, five‒day biochemical oxygen demand (BOD5, chemical oxygen demand (COD, total suspended solids (TSS, total nitrogen (TN and total phosphorus (TP. These parameters after the treatment became much lower values relative to those obtained before the treatment.

  3. Homogeneous sonophotolysis of food processing industry wastewater: Study of synergistic effects, mineralization and toxicity removal.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; Sanmartín, I; Gómez, P

    2013-03-01

    The mineralization of industrial wastewater coming from food industry using an emerging homogeneous sonophotolytic oxidation process was evaluated as an alternative to or a rapid pretreatment step for conventional anaerobic digestion with the aim of considerably reducing the total treatment time. At the selected operation conditions ([H(2)O(2)]=11,750ppm, pH=8, amplitude=50%, pulse length (cycles)=1), 60% of TOC is removed after 60min and 98% after 180min when treating an industrial effluent with 2114ppm of total organic carbon (TOC). This process removed completely the toxicity generated during storing or due to intermediate compounds. An important synergistic effect between sonolysis and photolysis (H(2)O(2)/UV) was observed. Thus the sonophotolysis (ultrasound/H(2)O(2)/UV) technique significantly increases TOC removal when compared with each individual process. Finally, a preliminary economical analysis confirms that the sono-photolysis with H(2)O(2) and pretreated water is a profitable system when compared with the same process without using ultrasound waves and with no pretreatment. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Preozonation of primary-treated municipal wastewater for reuse in biofuel feedstock generation

    Energy Technology Data Exchange (ETDEWEB)

    Mondala, Andro H.; Hernandez, Rafael; French, W. Todd; Estévez, L. Antonio; Meckes, Mark; Trillo, Marlene; Hall, Jacqueline

    2010-11-09

    The results of a laboratory scale investigation on ozone pretreatment of primary-treated municipal wastewater for potential reuse in fermentation processes for the production of biofuels and bio-based feedstock chemicals were presented. Semi-batch preozonation with 3.0% (w/w) ozone at 1 L min -1 resulted into a considerable inactivation of the indigenous heterotrophic bacteria in the wastewater with less than 0.0002% comprising the ozone-resistant fraction of the microbial population. The disinfection process was modeled using first-order inactivation kinetics with a rate constant of 4.39 10 -3 s -1. Chemical oxygen demand (COD) levels were reduced by 30% in 1-h experiments. COD depletion was also modeled using a pseudo-first-order kinetics at a rate constant of 9.50 10 -5 s -1. Biological oxygen demand (BOD 5) values were reduced by 60% up to 20 min of ozonation followed by a plateau and some slight increases attributed to partial oxidation of recalcitrant materials. Ozone also had no substantial effect on the concentration of ammonium and phosphate ions, which are essential for microbial growth and metabolism. Preliminary tests indicated that oleaginous microorganisms could be cultivated in the ozonated wastewater, resulting in relatively higher cell densities than in raw wastewater and comparable results with autoclave-sterilized wastewater. This process could potentially produce significant quantities of oil for biofuel production from municipal wastewater streams.

  5. Toxicity evaluation of wastewater collected at different treatment stages from a pharmaceutical industrial park wastewater treatment plant.

    Science.gov (United States)

    Ma, Ke; Qin, Zhe; Zhao, Zhongqing; Zhao, Chunxia; Liang, Shuxuan

    2016-09-01

    The toxicity of water-receiving bodies, the effluent and other treatment stages in wastewater treatment plants has recently been of interest to the public due to the lack of a regulated toxicity-based index for wastewater discharge in China. This study aimed to evaluate the conventional pollution parameters and toxicities of wastewaters collected at different treatment stages from a pharmaceutical industrial park wastewater treatment plant through dehydrogenase activity (DHA) and bioluminescent bacteria (Vibrio qinghaiensis) tests. The results of an analysis of conventional parameters indicated that the total suspended solids (TSS), chemical oxygen demand (COD), total nitrogen (TN), ammonia nitrogen (NH3N), and total phosphorus (TP) were largely removed after various treatments. However, the TN, NH3N and COD still exceeded the regulated standards. The tested pharmaceutical park effluents were mainly polluted with organic pollutants and nitrogenous. The toxicity test results indicated that the toxicities could be markedly reduced after treatment, with the toxicities of two out of the six effluent samples at different treatment stages being greater than the influent toxicity. Spearman's rank correlation coefficients indicated a significantly positive correlation between the toxicity values obtained using the DHA and Vibrio qinghaiensis tests. Compared with the DHA measurement, the Vibrio qinghaiensis test was faster and more sensitive. Meanwhile, the toxicity indicators were significantly and positively correlated with the TSS, TN, TP and COD concentrations. These results may aid the understanding of the toxicity of pharmaceutical industrial park wastewaters and toxicity removal using the treatment techniques that are currently utilized in China. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Activated carbon fiber filler in aerated bioreactor for industrial wastewater treatment.

    Science.gov (United States)

    Zhou, Dongkai; Hai, Reti; Wang, Wenxing; Zhao, Donglin; Wang, Shuo

    2012-01-01

    The aerated bioreactor is a promising technology for wastewater treatment. Activated carbon fiber (ACF) used as a biomembrane carrier in wastewater disposal has attracted much more concern recently. The high modulus polyacrylonitrile (PAN)-based ACF was successfully used as a biomembrane carrier for hard-to-biodegrade industrial organic wastewater disposal in a lab-scale aerated biomembrane reactor at room temperature. The biocompatibility test shows that the biomembrane grows quickly on the ACF filler (ACFF) surface; bacteria and microzoon can breed on the ACFF surface at high chemical oxygen demand (COD) concentration. The COD removal rate tests show that the ACFF bioreactor has high capability to remove COD.

  7. A Tool to Support Optimal Industrial Wastewater Treatment Design and Analysis

    DEFF Research Database (Denmark)

    Quaglia, Alberto; Pennati, Alessandra; Bozkurt, Hande

    2013-01-01

    Industrial Wastewater Treatment Plant (IWWTP) design is often based on in-house expert knowledge and experience. Because of time and resources constraints, only a small number of alternative treatment configurations and ideas are evaluated while designing an IWWTP. Consequently, the selected design...... may be suboptimal or disregard opportunities for water recycle or resource recovery and reuse. In this contribution, we propose a model-based toolbox developed to help wastewater professionals to screen among a large number of alternatives in order to identify the optimal treatment configuration from...... an economic cost-benefit perspective. The toolbox is demonstrated through a case study, dealing with oil refinery wastewater treatment and water recycle....

  8. The use of low-cost adsorbents for wastewater purification in mining industries.

    Science.gov (United States)

    Iakovleva, Evgenia; Sillanpää, Mika

    2013-11-01

    Recently, great attention has been paid to the environmental problems in mining industry. At present there are different ways of mineral processing, as well as various methods of wastewater treatment, most of them are expensive. Work is ongoing to find low-cost treatments. In this article, low-cost adsorbents, potentially useful for wastewater treatment on mining and metallurgical plants, are reviewed; their characteristics, advantages, and disadvantages of their application are compared. Also adsorption of different metals and radioactive compounds from acidic environment similar to composition of mining and metallurgical wastewaters is considered.

  9. Industrial wastewater treatment network based on recycling and rerouting strategies for retrofit design schemes

    DEFF Research Database (Denmark)

    Sueviriyapan, Natthapong; Suriyapraphadilok, Uthaiporn; Siemanond, Kitipat

    2015-01-01

    is employed to solve a network superstructure-based optimization problem formulated as Mixed Integer Linear and/or Non-Linear Programming (MILP/MINLP). Data from a petroleum refinery effluent treatment plant together with special design constraints are employed to formulate different design schemes based...... a generic model-based synthesis and design framework for retrofit wastewater treatment networks (WWTN) of an existing industrial process. The developed approach is suitable for grassroots and retrofit systems and adaptable to a wide range of wastewater treatment problems. A sequential solution procedure...... for the future development of the existing wastewater treatment process....

  10. Bioremediation and Detoxification of Synthetic Wastewater Containing Triarylmethane Dyes by Aeromonas hydrophila Isolated from Industrial Effluent

    OpenAIRE

    Ogugbue, Chimezie Jason; Sawidis, Thomas

    2011-01-01

    Economical and bio-friendly approaches are needed to remediate dye-contaminated wastewater from various industries. In this study, a novel bacterial strain capable of decolorizing triarylmethane dyes was isolated from a textile wastewater treatment plant in Greece. The bacterial isolate was identified as Aeromonas hydrophila and was shown to decolorize three triarylmethane dyes tested within 24 h with color removal in the range of 72% to 96%. Decolorization efficiency of the bacterium was a f...

  11. Experimental Study of Dye Removal from Industrial Wastewater by Membrane Technologies of Reverse Osmosis and Nanofiltration

    OpenAIRE

    Mohammad Fadhil Abid; Mumtaz Abdulahad Zablouk; Abeer Muhssen Abid-Alameer

    2012-01-01

    Currently, biological method has been utilized in the treatment of wastewater -containing synthetic dyes used by textile industries in Iraq. The present work was devoted to study the operating feasibility using reverse osmosis (RO) and nanofiltration (NF) membrane systems as an alternative treatment method of wastewater discharged from Iraqi textile mills. Acid red, reactive black and reactive blue dyes were selected, based on the usage rate in Iraq. Effects of dye concentration, pH of soluti...

  12. Microbial aspects of synthesis gas fed bioreactors treating sulfate and metal rich wastewaters

    NARCIS (Netherlands)

    Houten, van B.H.G.W.

    2006-01-01

    The use of synthesis gas fed sulfate-reducing bioreactors to simultaneously remove both oxidized sulfur compounds and metals shows great potential to treat wastewaters generated as a result of flue gas scrubbing, mining activities and galvanic processes. Detailed information about the phylogenetic

  13. Optimizing hydraulic retention times in denitrifying woodchip bioreactors treating recirculating aquaculture system wastewater

    Science.gov (United States)

    The performance of wood-based denitrifying bioreactors to treat high-nitrate wastewaters from aquaculture systems has not previously been demonstrated. Four pilot-scale woodchip bioreactors (approximately 1:10 scale) were constructed and operated for 268 d to determine the optimal range of design hy...

  14. Chemical and Microbiological Analysis of Certain Water Sources and Industrial Wastewater Samples in Dakahlia Governorate

    International Nuclear Information System (INIS)

    El-Fadaly, H.; El-Defrawy, M.M.; El-Zawawy, F.; Makia, D.

    1999-01-01

    The chemical analysis included quantitative measurement of electrical conductivity, alkalinity , hardness sulphate, ph, total dissolved solids, chloride, as well as dissolved oxygen was carried out. The microbiological examination for different water sources and industrial wastewater samples was also conducted. some of heavy metals, Co 2+ Cu 2+ Fe 3+ and Mn 2+ were determined in fresh water, while other metals, such as Cr 6+ , Co 2+ , Zn 2+ and Ni 2+ were measured in industrial wastewater. Results of the chemical analysis showed that all measured parameters were found within the limitation either national or international law, except some samples which showed higher values than the permissible limits for some measured parameters. The microbiological analysis exhibited presence of yeasts, fungi and bacteria. Most bacterial isolates were short rod, spore formers as well as coccoid shaped bacteria. The efficiency of water treatment process on the reduction of microbial load was also calculated. Regarding the pathogenic bacteria, data showed that neither water samples nor industrial wastewater contain pathogens when using specific cultivation media for the examination. Furthermore, data proved the possibility of recycling of the tested industrial wastewater on which some microorganisms can grow. Data showed that the percent of heavy metals removal can reach to more than 70% in some cases as a result to bacterial treatment of industrial wastewater

  15. Treating ammonium-rich wastewater with sludge from water treatment plant to produce ammonium alum

    Directory of Open Access Journals (Sweden)

    Wen-Po Cheng

    2016-03-01

    Full Text Available This study applies a process to treat ammonium-rich wastewater using alum-generated sludge form water purification plant, and gain economic benefit by producing ammonium alum (Al(NH4(SO42·12H2O. The factors affecting production of ammonium alum include molar ratio of ammonium to aluminum concentration, sulfuric acid concentration, mixing speed, mixing time, standing time, and temperature. According to the equation for the ammonium removal reaction, the theoretical quantity of ammonium alum was calculated based on initial and final concentrations of ammonium. Then, the weight of ammonium alum crystal was divided by the theoretical weight to derive the recovery ratio. The optimum sludge and sulfuric acid dosage to treat about 17 g L−1 ammonium wastewater are 300 g L−1 and 100 mL L−1, respectively. The optimal dosage for wastewater is molar ratio of ammonium to aluminum of about 1 due to the aluminum dissolving in acidified wastewater. The ammonium removal efficiency is roughly 70% and the maximum recovery ratio for ammonium alum is 93% when the wastewater is mixed for 10 min at the mixing velocity gradient of 100 s−1. Ammonium alum production or ammonium removal can be enhanced by controlling the reaction at low temperatures.

  16. A new nanocomposite forward osmosis membrane custom-designed for treating shale gas wastewater

    Science.gov (United States)

    Qin, Detao; Liu, Zhaoyang; Delai Sun, Darren; Song, Xiaoxiao; Bai, Hongwei

    2015-01-01

    Managing the wastewater discharged from oil and shale gas fields is a big challenge, because this kind of wastewater is normally polluted by high contents of both oils and salts. Conventional pressure-driven membranes experience little success for treating this wastewater because of either severe membrane fouling or incapability of desalination. In this study, we designed a new nanocomposite forward osmosis (FO) membrane for accomplishing simultaneous oil/water separation and desalination. This nanocomposite FO membrane is composed of an oil-repelling and salt-rejecting hydrogel selective layer on top of a graphene oxide (GO) nanosheets infused polymeric support layer. The hydrogel selective layer demonstrates strong underwater oleophobicity that leads to superior anti-fouling capability under various oil/water emulsions, and the infused GO in support layer can significantly mitigate internal concentration polarization (ICP) through reducing FO membrane structural parameter by as much as 20%. Compared with commercial FO membrane, this new FO membrane demonstrates more than three times higher water flux, higher removals for oil and salts (>99.9% for oil and >99.7% for multivalent ions) and significantly lower fouling tendency when investigated with simulated shale gas wastewater. These combined merits will endorse this new FO membrane with wide applications in treating highly saline and oily wastewaters. PMID:26416014

  17. The microbial aspects of constructed wetlands treating simulated wastewater

    International Nuclear Information System (INIS)

    Pervez, A.; Firdus, S.

    2005-01-01

    The microbial populations (bacteria, actinomycetes and fungi) in six different types of 68 dm/sup 3/ experimental constructed wetlands with or with reed were quantified using standard counts of colony forming units grown on different types of medias. The wetlands were supplied with a simulated wastewater and number of environmental variables were measured, including COD, temperature, pH, Oxygen concentration, suspended solids, NH/sub 4//sup +/, NO/sub 3//sup -/ and HPO/sub 4//sup 2-/. Mean number of colony forming units of bacteria, actinomycetes and fungi differed significantly between each system, sample dates and depths. Correlation coefficient for variables were calculated to determine whether a relationship between biological and physico-chemical factors at all samples depths could be detected. Not surprisingly the numbers of bacteria and actinomycetes were strongly positively correlated with temperature and oxygen concentration. However, fungal populations were partially correlated with temperature. No correlation was found between the number of any microorganisms and the levels of HPO/sub 4//sup 2-/ in the effluent. (author)

  18. Integrated wastewater management by reuse and recycling in a textile industry: a case study in Thailand

    International Nuclear Information System (INIS)

    Javed, M.R.; Trankler, J.

    2005-01-01

    Increasing stringent environmental legislation, scarcity of resources and development of treatment and management techniques for wastewater, have made recycling and reuse feasible and economical in many industrial processes. Wastewater management by integrating all available techniques was studied for reuse and recycling in a textile industry. Cotton and silk fabrics were main products of the selected industry. Approach was divided in to five parts, to achieve the objectives of reuse and recycling: in-house water consumption evaluation, segregation study, optimizing existing WWTP, treatability study and advanced treatment for final effluent to fulfill reuse criteria. Water consumption evaluation was done by in-house survey. Segregation study was performed by analyzing different wastewater streams. Efficiency of existing WWTP for COD and BOD removal was assessed and optimized. Treatability of dye wastewater by ozonation, chemical and nanofiltration was studied. Treatment study of final effluent for TDS and color removal by nanofiltration and chemical treatment was performed. Analyses show the possibilities to conserve and optimize water consumption up to 30% in the production processes by in-house improvement. Segregation study shows that up to 15% wastewater from less polluted streams can be recycled back. Adopting separate efficient treatment techniques could fulfill reuse criteria for remaining wastewater streams (50%). (author)

  19. Application of Sayong Ball Clay Membrane Filtration for Ni (II Removal from Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    S.F. Mohd Noor

    2017-11-01

    Full Text Available Wastewater containing heavy metals, such as nickel ions (Ni2+, discharged from industry to water streams poses a serious threat because even at low concentrations, it does not naturally degrade and is toxic to human and aquatic life. This article reviews a novel technique for wastewater treatment using a Sayong ball clay (SBC membrane to remove nickel from industrial wastewater. SBC powder was achieved through milling using a planetary ball mill (milling time; 10, 20 and 30 h, further labelled as SBC 10, SBC 20 and SBC 30, with a ball-to-powder of ratio 7:1 and rotation speed of 300 rpm. The physical characteristics of the apparent porosities, bulk density and shrinkage were investigated. XRD was used to study the phase, while FESEM was used to analyse the microstructure of the fired membrane. The FESEM microstructure indicates a decreased particle size (SB30. Filtration was conducted using a dead-end filtration system. The fabricated SBC 10, 20 and 30 membranes showed significant removal of nickel from industrial wastewater—88.87%, 82.96% and 85.13%, respectively. This study revealed that the SBC membrane is a promising membrane to remove nickel from industrial wastewater. The results also indicate the possibility of highlighting the introduced technique as a new technique for the treatment of industrial wastewater. As a new trend for waste management, pollution prevention could be applied in Malaysia as one of the advanced biotechnologies to solve various environmental problems. Keywords: environmental management, wastewater treatment, waste processing, heavy metals

  20. Oil removal from industrial wastewater using flotation in a ...

    African Journals Online (AJOL)

    This paper investigates the flotation of oil from wastewater in a laboratory-scale mechanically agitated flotation cell. Mechanical flotation cells are used commercially for oil flotation but, to the authors' best knowledge, there are no studies on their flotation performance in the literature. Some researchers have suggested that ...

  1. For the Fenton process in a sequential downflow and upflow system to treat textile dyeing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W.K.; Ko, G.B.; Cho, S.J. [Dept. of Civil and Environmental Engineering, Hanyang Univ., Kyounggi (Korea); Lee, S.H. [Dept. of Environmental Engineering, Sangmyung Univ., Cheonan (Korea)

    2003-07-01

    Wastewater from textile dyeing industry is characterized by high temperature, pH, pollution loading such as color and COD which are containing refractory, toxic and high molecular weight compounds. It is therefore, presumed to be very resistant to microbial degradation. Textile dyeing wastewater is therefore, presumed to be very resistant to microbial degradation. Combined processes are usually applied, which are chemical oxidation and biological process for textile dyeing wastewater in order to satisfy water quality standards. Fenton process as advanced oxidation process is well known as effective process for the removal of color and recalcitrant organics. However, the exactly predominant reaction mechanisms during Fenton process are not well explained among coagulation, oxidation and sedimentation so far. This research attempts to evaluate the predominant reaction with comparable results of ferric coagulation and oxidation for the Fenton process. (orig.)

  2. Innovative bio filtration for treatment of wastewater from communities and industry; Biofiltracion innovadora para el tratamiento de aguas residuales producidas por poblaciones e industrias

    Energy Technology Data Exchange (ETDEWEB)

    Sekoulov, I.; Rudiger, A.; Barz, M.

    2009-07-01

    Nowadays biological treatments are more and more required to clean municipal and industrial wastewater. More than 500 wastewater treatment plant use bio filtration. Bio filtration is a compact aerated reactor which does not imply expensive investments anymore. The real advantage of using bio filters is the aptitude to adapts the treatment to a wide range of entering polluting load, and also to low temperatures of wastewater. However, this technology needs a frequent cleaning that involves to stop the installation. Aquabiotec has solved this issue by enhancing a sequential cleaning. This new generation of bio filtration is able to treat wastewater steadily, with the same efficiency (>90%) and for lower costs compared to a classical bio filter. (Author) 6 refs.

  3. Characterization of persistent colors and decolorization of effluent from biologically treated cellulosic ethanol production wastewater.

    Science.gov (United States)

    Shan, Lili; Liu, Junfeng; Yu, Yanling; Ambuchi, John J; Feng, Yujie

    2016-05-01

    The high chroma of cellulosic ethanol production wastewater poses a serious environmental concern; however, color-causing compounds are still not fully clear. The characteristics of the color compounds and decolorization of biologically treated effluent by electro-catalytic oxidation were investigated in this study. Excitation-emission matrix (EEM), fourier transform infrared spectrometer (FTIR), UV-Vis spectra, and ultrafiltration (UF) fractionation were used to analyze color compounds. High chroma of wastewater largely comes from humic materials, which exhibited great fluorescence proportion (67.1 %) in the biologically treated effluent. Additionally, the color compounds were mainly distributed in the molecular weight fractions with 3-10 and 10-30 kDa, which contributed 53.5 and 34.6 % of the wastewater color, respectively. Further decolorization of biologically treated effluent by electro-catalytic oxidation was investigated, and 98.3 % of color removal accompanied with 97.3 % reduction of humic acid-like matter was achieved after 180 min. The results presented herein will facilitate the development of a well decolorization for cellulosic ethanol production wastewater and better understanding of the biological fermentation.

  4. Using treated wastewater to save wetlands impacted by climate change and pumping.

    Science.gov (United States)

    McFarlane, D J; Smith, A; Bekele, E; Simpson, J; Tapsuwan, S

    2009-01-01

    Wetlands occur where the watertable which underlies much of Perth intersects the land surface. Regional groundwater levels have been falling since the 1970s as a result of lower rainfall and increased extraction causing a loss of environmental and social values. This paper examines a scheme to add almost 2 GL/yr of treated wastewater to infiltration galleries immediately down-gradient of Perry Lakes so that the wetlands may be restored. Modelling suggest that groundwater levels would be raised up-gradient of the galleries, increasing both lake levels and groundwater supplies in the vicinity. It is not envisaged that wastewater will enter the lakes. Adding treated wastewater to nearby trial galleries has shown that phosphorus, pathogens and organic carbon are greatly reduced within 5 to 50 m. Nitrogen levels are less reduced but are similar to those in the lakes and nearby aquifer. It is estimated that the wetlands add about $54 m to land prices near the lakes and would add more than $24M to the sale price of proposed nearby land if they contain water. If successful, the proposal could be a test case for the use of treated wastewater to create hydraulic barriers against salt water intrusion into coastal areas.

  5. Technical and Economic Comparison of Conventional Wastewater Treatment Systems in the Sugar Industries in Iran

    Directory of Open Access Journals (Sweden)

    Mehdi Ahmadi

    2005-03-01

    Full Text Available Iran’s location in an arid and water scarce area characterized by qualititative and quantitative degradation in its water resources makes strict planning imperative for reduced water consumption and wastewater treatment and reuse, especially in the industry sector. The technical and economic evaluation of various industrial treatment processes is a key factor in the success of such schemes in the face of the effects of climate variety, high wastewater treatment costs, and environmental factors on selecting a most suitable alternative for industrial wastewater treatment. The situation is even more critical in the case of the sugar industry as the largest pollutant source and especially because more than 90% of its facilities are located on plains with a negative water balance. Reviewing wastewater problems associated with the Iranian sugar facilities, this paper will attempt to perform an economic assessment and a comparison of conventional anaerobic-aerobic processes under various conditions in order to identify the best aleternative and to determine the most important environmental and cost factors affecting the selection of a desirable alternative. For this purpose, six combined treatment systems are selected and their construction and operation costs and detailed uniform annual cost sensitivity analysis based on the most important parameters are presented. Finally, two different combined wastewater treatment systems of UASB + facultative lagoons and UASB + trickling filters will be introduced as the best treatment processes for Iranian conditions.

  6. Occurrence of antibiotics in pharmaceutical industrial wastewater, wastewater treatment plant and sea waters in Tunisia.

    Science.gov (United States)

    Tahrani, Leyla; Van Loco, Joris; Ben Mansour, Hedi; Reyns, Tim

    2016-04-01

    Antibiotics are among the most commonly used group of pharmaceuticals in human medicine. They can therefore reach surface and groundwater bodies through different routes, such as wastewater treatment plant effluents, surface runoff, or infiltration of water used for agricultural purposes. It is well known that antibiotics pose a significant risk to environmental and human health, even at low concentrations. The aim of the present study was to evaluate the presence of aminoglycosides and phenicol antibiotics in municipal wastewaters, sea water and pharmaceutical effluents in Tunisia. All analysed water samples contained detectable levels of aminoglycoside and phenicol antibiotics. The highest concentrations in wastewater influents were observed for neomycin and kanamycin B (16.4 ng mL(-1) and 7.5 ng mL(-1), respectively). Chloramphenicol was found in wastewater influents up to 3 ng mL(-1). It was observed that the waste water treatment plants were not efficient in completely removing these antibiotics. Chloramphenicol and florfenicol were found in sea water samples near aquaculture sites at levels up to, respectively, 15.6 ng mL(-1) and 18.4 ng mL(-1). Also aminoglycoside antibiotics were found near aquaculture sites with the highest concentration of 3.4 ng mL(-1) for streptomycin. In pharmaceutical effluents, only gentamycin was found at concentrations up to 19 ng mL(-1) over a sampling period of four months.

  7. Physical-chemical effects of irrigation with treated wastewater on Dusky Red Latosol soil

    Directory of Open Access Journals (Sweden)

    Vanessa Ribeiro Urbano

    2015-11-01

    Full Text Available The current water crisis underlines the importance of improving water management. The use of effluent from secondary treatment in agriculture can reduce the discharge of effluent into natural bodies and provide nutrients to crops. This study evaluated the physical and chemical properties of a Dusky Red Latosol soil that had been irrigated with treated wastewater. Conducted at the Center of Agricultural Sciences (CCA of Federal University of São Carlos (UFSCar, in Araras/São Paulo/Brazil, 18 undisturbed soil samples were collected and deposited on a constant-head permeameter in order to simulate the irrigation of five growth cycles of lettuce (Lactuca sativa L., organized in five different treatments and one control group. For each treatment 0.58 L, 1.16 L, 1.74 L, 2.32 L, and 2.90 L of treated wastewater and distilled water were applied . The treated wastewater came from a domestic waste treatment plant. After the water filtered through the soil, samples of treated wastewater were collected for analyses of electrical conductivity (EC, sodium adsorption ratio (SAR, turbidity, pH, Na, K, Mg, P and Ca and, in the soil the granulometry, complete fertility, exchangeable sodium percentage (ESP and saturated hydraulic conductivity (Ksat. The Ksat decreased, but did not alter the infiltration of water and nutrients in the soil. The concentration of nutrients in the soil increased, including Na, which raises the need for monitoring soil’s salinity. In conclusion, the application of wastewater did not cause damage to the physical properties of the soil, but resulted in a tendency towards salinization.

  8. 2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Mike [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2013 through October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Groundwater monitoring data; Status of special compliance conditions; Noncompliance issues; and Discussion of the facility’s environmental impacts During the 2014 reporting year, an estimated 10.11 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.

  9. 2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of special compliance conditions • Discussion of the facility’s environmental impacts During the 2012 reporting year, an estimated 11.84 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the Ground Water Quality Rule Primary and Secondary Constituent Standards.

  10. 2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    David Frederick

    2012-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA-000160-01), for the wastewater reuse site at the Idaho National Laboratory Site's Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: (1) Facility and system description; (2) Permit required effluent monitoring data and loading rates; (3) Groundwater monitoring data; (4) Status of special compliance conditions; and (5) Discussion of the facility's environmental impacts. During the 2011 reporting year, an estimated 6.99 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 13 million gallons per year. Using the dissolved iron data, the concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the Ground Water Quality Rule Primary and Secondary Constituent Standards.

  11. Wastewaters from pulp industry: trends and challengers; Los residuos liquidos en la industrial de celulosa: avances y desafios

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, C.; Vidal, G.

    2003-07-01

    This paper shows the strategy used by the pulp industry in order to reduce the wastewater impact in the environment. The changes in the process technologies has been used as a main strategy by this industry. Also, it has been introduced the primary and secondary treatment. However, environmental impact due to specific compounds like resinic acids,sterols, colour and nutrients are not solved yet: tertiary treatment should be implemented for their solution. (Author) 49 refs.

  12. The effect of temperature on the efficiency of industrial wastewater nitrification and its (genotoxicity

    Directory of Open Access Journals (Sweden)

    Gnida Anna

    2016-03-01

    Full Text Available The paper deals with the problem of the determination of the effects of temperature on the efficiency of the nitrification process of industrial wastewater, as well as its toxicity to the test organisms. The study on nitrification efficiency was performed using wastewater from one of Polish chemical factories. The chemical factory produces nitrogen fertilizers and various chemicals. The investigated wastewater was taken from the influent to the industrial mechanical-biological wastewater treatment plant (WWTP. The WWTP guaranteed high removal efficiency of organic compounds defined as chemical oxygen demand (COD but periodical failure of nitrification performance was noted in last years of the WWTP operation. The research aim was to establish the cause of recurring failures of nitrification process in the above mentioned WWTP. The tested wastewater was not acutely toxic to activated sludge microorganisms. However, the wastewater was genotoxic to activated sludge microorganisms and the genotoxicity was greater in winter than in spring time. Analysis of almost 3 years’ period of the WWTP operation data and laboratory batch tests showed that activated sludge from the WWTP under study is very sensitive to temperature changes and the nitrification efficiency collapses rapidly under 16°C. Additionally, it was calculated that in order to provide the stable nitrification, in winter period the sludge age (SRT in the WWTP should be higher than 35 days.

  13. Toxicity Evaluation of Through Fish Bioassay Raw Bulk Drug Industry Wastewater After Electrochemical Treatment

    Directory of Open Access Journals (Sweden)

    S Satyanarayan

    2011-10-01

    Full Text Available Considering the high pollution potential that the synthetic Bulk Drug industry Wastewater (BDW possesses due to the presence of variety of refractory organics, toxicity evaluation is of prime importance in assessing the efficiency of the applied wastewater treatment system and in establishing the discharge standards. Therefore, in this study the toxic effects of high strength bulk drug industry wastewater before and after electrochemical treatment on common fish Lebistes reticulatus-(peter were studied under laboratory conditions. Results indicated that wastewater being very strong in terms of color, COD and BOD is found to be very toxic to the studied fish. The LC50 values for raw wastewater and after electrochemical treatment with carbon and aluminium electrodes for 24, 48, 72 and 96 hours ranged between, 2.5-3.6%, 6.8-8.0%, 5.0-5.8% respectively. Carbon electrode showed marginally better removals for toxicity than aluminium electrode. It was evident from the studies that electrochemical treatment reduces toxicity in proportion to the removal efficiency shown by both the electrodes. The reduction in toxicity after treatment indicates the intermediates generated are not toxic than the parent compounds. Furthermore, as the electrochemical treatment did not result in achieving disposal standards it could be used only as a pre-treatment and the wastewater needs further secondary treatment before final disposal.

  14. Separation of Mercury Resistant Bacteria from Wastewater of Milk, Detergent and Ceramic Industry

    Directory of Open Access Journals (Sweden)

    M. Moghbeli , F. Shakeri and H. Hashemi-Moghaddam

    2011-09-01

    Full Text Available Use of microorganisms for removing mercury is an effective technology for the treatment of industrial wastewaters and can become an effective tool for the remediation of man-impacted coastal ecosystems with this metal. In this study, seven types of mercury resistant bacteria were separated from industrial waste and minimum inhibitory concentration (MIC, were determined for these bacteria. Results showed that two strains of bacteria, which isolated from waste water detergent plants, are more resistant to mercury and able to grow at the presence of 52 ppm of mercuric chloride. These bacteria could be used for biological treatment of mercury in contaminated wastewater.

  15. Biochars made from agro-industrial by-products remove chlorine from water and wastewater

    Science.gov (United States)

    Tzachristas, Andreas; Manariotis, Ioannis D.; Karapanagioti, Hrissi K.

    2017-04-01

    Chlorination is the most common disinfection process for water and wastewater. For the industrial use of water in food production, chlorine can add undesired taste and odor to the final product. For this reason, dechlorination is desired for food industries that use municipal tap water. For treated wastewater discharge or reuse, chlorine can be toxic to the receiving aqueous systems and to the irrigated plants. In both the above cases, dechlorination is also required. Traditionally activated carbon has been used as the ideal material for the removal of chlorine. The main mechanisms that describe the interaction between activated carbon and HOCl or OCl- are described by the following equations (AWWA, 1990): HOCl + C* → C*O + H+ + Cl- (1), OCl- + C* → C*O + Cl- (2) Where C* and C*O represent the activated carbon surface and a surface oxide, respectively. The present study proposes the use of agro-industrial by-products for the production of biochars that will be used for dechlorination of tap-water used for food-industry production. Different raw materials such as malt spent rootlets, coffee residue, olive and grape seeds, etc. are used for the production of biochar. Various temperatures and air-to-solid ratios are tested for optimizing biochar production. Batch tests as well as a column test are employed to study the dechlorination kinetics of the different raw and biochar materials as well as those of commercial activated carbons. The removal kinetics are faster during the first hour; then, removal continues but with a slower rate. Most of the biochars tested (with 3 mg of solid in 20 mL of chlorine solution at initial concentration Co=1.5 mg/L) demonstrated removal efficiencies with an average of 9.4 ± 0.5 mg/g. For the two commercial activated carbons, removal efficiencies were 11.4 ± 0.2 mg/g. The first-order constant k1 ranged between 0.001 and 0.014 (min-1) for the biosorbents and the biochars and it was equal to 0.017 (min-1) for the commercial

  16. Effect of Membrane Type for the Treatment of Organized Industrial Zone (OIZ) Wastewater with a Membrane Bioreactor (MBR): Batch Experiments

    OpenAIRE

    Oktay Özkan; İbrahim Uyanık

    2017-01-01

    Organized industrial zone (OIZ) wastewater is a mixed wastewater that is contributed by both municipal use and from different industrial sectors. Since MBR has advantages over conventional treatment plants, membrane types and fouling become the most important parameters in the treatment of this kind of wastewater. In this study, six different membrane types were used to find the most suitable membrane with the least resistivity to fouling. Three different microfiltration (MF) and ultrafiltrat...

  17. Biofuel application of biomass obtained from a meat industry wastewater plant through the flotation process. A case study

    Energy Technology Data Exchange (ETDEWEB)

    De Sena, Rennio F.; Claudino, Andreia; Moretti, Karine; Bonfanti, Iris C.P.; Moreira, Regina F.P.M.; Jose, Humberto J. [Laboratory of Energy and the Environment LEMA, Department of Chemical Engineering and Food Engineering EQA, Federal University of Santa Catarina UFSC, Center of Tecnology CTC, 88040-900 Florianopolis, SC (Brazil)

    2008-01-15

    Physicochemical treatment of meat industry wastewater is used to increase the organic matter removal efficiency, and it generates great amounts of sludge. Treatment using commercial ferric sulfate as coagulant for this specific wastewater gave high organic matter removals, decreasing considerably the amount of waste material to be treated in biological systems, and also allowing the obtention of 0.83-0.87 kg of biomass fuel for each m{sup 3} of treated wastewater. Due to sanitary, environmental problems and operational costs related to the discharge, land disposal and re-use of wastes, the utilization of this Biofuel (dried sludge) for steam generation has shown to be a viable alternative. This type of fuel has a high heating value, and it is a renewable energy source. The combustion test with a Biofuel to sawdust ratio of 4:1 met the technical requirements for the characterization of this promising fuel; nevertheless, operating conditions must be well designed to achieve NO{sub X} and SO{sub 2} emissions below local and/or international limits. (author)

  18. Nitritation and N2O Emission in a Denitrification and Nitrification Two-Sludge System Treating High Ammonium Containing Wastewater

    Directory of Open Access Journals (Sweden)

    Guangxue Wu

    2014-10-01

    Full Text Available The effective management of high ammonium containing wastewater is important for the sustainable development of the wastewater industry. A pre-denitrification and post-nitrification two-sludge system was proposed to treat high ammonium containing wastewater with low carbon-to-nitrogen (C/N ratios. In the system, pre-denitrification was adopted to use organic carbon in raw wastewater efficiently for nitrogen removal, while post-nitrification was adopted to achieve nitritation. System performance and the characteristics of nitrous oxide (N2O emission were examined. As to the influent chemical oxygen demand (COD and ammonium nitrogen (NH4-N concentration, both 800 mg/L, nitrogen removal was mainly through pre-denitrification, and the nitrogen removal percentage was 43.4%. In post-nitrification, nitritation was achieved with a nitrite accumulation efficiency of 97.8% and a NH4-N removal loading rate of 0.45 g/(L·d. With nitrite as the electron acceptor during denitrification, its removal rate increased, while the N2O emission factor decreased with increasing C/N ratios. Nitrification was affected significantly by the aeration rate. When the aeration rate was below 0.6 L/min, the NH4-N removal rate increased, while the N2O emission rate decreased with increasing aeration rates. However, when the aeration rate was above 0.6 L/min, it had little influence on N2O emission. During nitrification, N2O emission factors decreased exponentially with increasing ammonium oxidation rates.

  19. Identification of nitrous oxide emissions from green areas of Chihuahua City irrigated with treated wastewater.

    Science.gov (United States)

    Navarro-Gómez, Carmen Julia; Herrera-Peraza, Eduardo F; Alcocer-Yamanaka, Victor Hugo; Collins-Martínez, Virginia H; Quiñones-Montenegro, Luisa Y; Trujillo-Navarrete, Balter; Espino-Valdes, Maria Socorro

    2013-03-01

    Since 2000, the city of Chihuahua had a distribution system of treated wastewater for irrigation of green areas and has replaced this water for processes that do not require the consumption of drinking water. This replacement was necessary in order to meet the growing demand for potable water which has exceeded the current supply of 700 L (184,88 gallons) per second. Nowadays it is necessary to identify and assess the risks to public health and the environment due to the substitution of drinking water by treated wastewater in the last 10yr. Treated wastewater contains compounds whose effects have not been evaluated when used for irrigation in public green areas. Therefore, it is not known whether there is a danger to the health of park visitors due to exposure and/or inhalation of the emitted gases, accidental ingestion of water, or impact to the environment. The purpose of the research, using an experimental prototype, is to identify the changes from nitrogen present in the treated wastewater to nitrous oxide. The research objective is the generation of data to simulate a regional scale at this stage, which will be analyzed and statistically validated using Minitab and Origin software. The experiment was performed using three different samples to compare water quality: drinking water treated wastewater, and water with nitrogen-based fertilizer (urea). Prototypes were filled with two types of soil: sand and clay Each type of water was sprinkled on the prototype, grass was planted in it, and the prototype was equipped with samplers to capture the gas in the root zone. The authors found high emissions of nitrous oxide in the clay-filled lysimeters, and climate and growing conditions of vegetation were the most important factors for producing nitrous oxide. Major problems in the ecosystem arise from solutions that are not based on environmental public policy research or experimentation. For example, before application a specific policy or regulation, research should

  20. Biosorption of hexavalent chromium in a tannery industry wastewater using fungi species

    Directory of Open Access Journals (Sweden)

    D. Sivakumar

    2016-03-01

    Full Text Available The isolated fungi species of different kinds from chromium contaminated soil sites located in Nagalkeni, Chennai were used for reducing chromium(VI in a tannery industry wastewater of Nagalkeni, Chennai.  The experiments were conducted to know biosorption potential of isolated fungi species for removing chromium(VI in a tannery industry wastewater against the different pH, fungi biomass and chromium(VI concentration (dilution ratio.  The results of this study indicated that the order of maximum removal of chromium(VI by an isolated fungi species at an optimum pH of 3, fungi biomass of 4g andan initial chromium(VI concentration of 18.125 mg/L (dilution ratio 4is A. niger > A. flavus > A. fumigatus > A. nidulans > A. heteromorphus > A. foetidus > A. viridinutans.  This study found that the maximum removal of chromium(VI was achieved by Aspergillus niger (96.3 % than other fungi species at chromium(VI concentration of 18.125 mg/Lin a tannery industry wastewater. The chromium removal from tannery industry wastewater was validated by checking chromium removal in an aqueous solution and by checking the removal efficiency of other parameters in a tannery industry wastewater using same isolated A. niger.  Biosorption model was proposed to simulate the experimental condition for removing chromium(VI in a tannery industry wastewater by all isolated fungi species. The R2 and  values of the proposed model predicted that the proposed biosorption model is very much useful for predicting the trend of reduction potential of chromium(VI in a tannery industry wastewater by all isolated fungi species.  This study suggested that one could select the type of fungi species, ion concentration level, selection of treatment period, quantity of biomass to be used, and pH level of the medium, to achieve the highest reduction of any toxic metals from any contaminated water, wastewater and soil environment.

  1. A Photocatalytic Rotating Disc Reactor with TiO₂ Nanowire Arrays Deposited for Industrial Wastewater Treatment.

    Science.gov (United States)

    Li, Fang; Szeto, Wai; Huang, Haibao; Li, Jiantao; Leung, Dennis Y C

    2017-02-22

    A photocatalytic rotating disc reactor (PRD-reactor) with TiO₂ nanowire arrays deposited on a thin Ti plate is fabricated and tested for industrial wastewater treatment. Results indicate that the PRD-reactor shows excellent decolorization capability when tested with methyl orange (>97.5%). Advanced oxidation processes (AOP), including photocatalytic oxidation and photolytic reaction, occurred during the processing. Efficiency of the AOP increases with reduction in light absorption pathlength, which enhanced the photocatalytic reaction, as well as by increasing oxygen exposure of the wastewater thin film due to the rotating disc design. It is found that, with a small dosage of hydrogen peroxide, the mineralization efficiency of industrial biodegraded wastewater can be enhanced, with a superior mineralization of >75% total organic carbon (TOC) removal. This is due to the fact that the TiO₂ photocatalysis and hydrogen peroxide processes generate powerful oxidants (hydroxyl radicals) that can strongly improve photocatalytic oxidation efficiency. Application of this industrial wastewater treatment system is benefited from the TiO₂ nanowire arrays, which can be fabricated by a mild solvothermal method at 80 °C and under atmospheric pressure. Similar morphologies and microstructures are found for the TiO₂ nanowire arrays deposited on a large metal Ti disc, which makes the wastewater treatment process more practical and economical.

  2. Long-term surveillance of sulfate-reducing bacteria in highly saline industrial wastewater evaporation ponds.

    Science.gov (United States)

    Ben-Dov, Eitan; Kushmaro, Ariel; Brenner, Asher

    2009-02-18

    Abundance and seasonal dynamics of sulfate-reducing bacteria (SRB), in general, and of extreme halophilic SRB (belonging to Desulfocella halophila) in particular, were examined in highly saline industrial wastewater evaporation ponds over a forty one month period. Industrial wastewater was sampled and the presence of SRB was determined by quantitative real-time PCR (qPCR) with a set of primers designed to amplify the dissimilatory sulfite reductase (dsrA) gene. SRB displayed higher abundance during the summer (10(6)-10(8) targets ml(-1)) and lower abundance from the autumn-spring (10(3)-10(5) targets ml(-1)). However, addition of concentrated dissolved organic matter into the evaporation ponds during winter immediately resulted in a proliferation of SRB, despite the lower wastewater temperature (12-14 degrees C). These results indicate that the qPCR approach can be used for rapid measurement of SRB to provide valuable information about the abundance of SRB in harsh environments, such as highly saline industrial wastewaters. Low level of H2S has been maintained over five years, which indicates a possible inhibition of SRB activity, following artificial salination (approximately 16% w/v of NaCl) of wastewater evaporation ponds, despite SRB reproduction being detected by qPCR.

  3. Advanced oxidation processes: a review of fundamentals and applications in the treatment of urban and industrial wastewaters

    Directory of Open Access Journals (Sweden)

    Karla Santos de Araújo1;

    2016-04-01

    Full Text Available Contamination of water by toxic and/or recalcitrant species has great environmental impacts. In this context, Advanced Oxidation Processes (AOPs - technologies that principally use the hydroxyl radical (HO● for oxidation - have emerged as promising alternatives in treating urban and industrial wastewaters. This study reviewed the literature on POAs and presented data regarding the efficiency of these processes in pollutant degradation, comparing the theoretical reasoning and its industrial applications. The fundamentals and major applications of AOPs (chemical, photochemical, electrochemical, sonochemical and ozone-based processes, as well as their advantages and disadvantages, are described in this review. AOPs have been considered an effective alternative from a technical, economic and environmental viewpoint for the degradation of pollutants in effluents and industrial wastewater, despite having limitations such as high cost of available energy sources, development of new low-cost catalytic materials and construction of full-scale reactors. It is greatly important to the industrial application of AOPs to optimize the effectiveness of these factors.

  4. Treatment of wastewater from rubber industry in Malaysia ...

    African Journals Online (AJOL)

    Presently, Malaysia is the third largest rubber producer in the world, whereby the rubber industry is an economically and socially significant industry. Rubber industry consumes large volumes of water, uses chemicals and other utilities and produces enormous amounts of wastes and effluent. Discharge of untreated rubber ...

  5. Ecotoxicological potential of antibiotic pollution-industrial wastewater: bioavailability, biomarkers, and occurrence in Mytilus galloprovincialis.

    Science.gov (United States)

    Zouiten, Amina; Beltifa, Asma; Van Loco, Joris; Mansour, Hedi Ben; Reyns, Tim

    2016-08-01

    Environmental pollution by pharmaceutical residues has become a major problem in many countries worldwide. However, little is known about the concentrations of pharmaceuticals in water sources in Tunisia. Residues in the natural environment have been of increasing concern due to their impact on bacteria resistance development and toxicity to natural communities and ultimately to public health. In this work, we collected the wastewater sample from a pharmaceutical industry, which specializes in the antibiotics manufacture, during the years 2014-2015. Generally, this effluent is discharged into the marine environment and causes environmental problems. The Mediterranean mussel Mytilus galloprovincialis was commonly used as a model organism for its peculiar morphofunctional properties which also make it an excellent marine environmental biomonitoring species. The histological sections of mussel, which are exposed at different dilutions of pharmaceutical wastewater (PW), indicate a large pathological power revealed on the gills. On the other hand, genotoxicity of the studied effluent was evaluated using comet assay for quantification of DNA fragmentation in gill cells. Results show that PW exhibited a statistically significant (p < 0.001) genotoxic effect in a dose-dependent manner. However, the toxic effects of PW decreased significantly after its treatment with Bacillus atrophaeus. Toxicities can be imputed to the presence of antibiotics. In fact, chemical analysis of the gills of mussel M. galloprovincialis using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) showed the presence of some antibiotic residues. These concentrations decrease to half in mussels treated with PW biodegraded by B. atrophaeus.

  6. Impact of treated urban wastewater for reuse in agriculture on crop response and soil ecotoxicity.

    Science.gov (United States)

    Belhaj, Dalel; Jerbi, Bouthaina; Medhioub, Mounir; Zhou, John; Kallel, Monem; Ayadi, Habib

    2016-08-01

    The scarcity of freshwater resources is a serious problem in arid regions, such as Tunisia, and marginal quality water is gradually being used in agriculture. This study aims to study the impact of treated urban wastewater for reuse in agriculture on the health of soil and food crops. The key findings are that the effluents of Sfax wastewater treatment plant (WWTP) did not meet the relevant guidelines, therefore emitting a range of organic (e.g., up to 90 mg L(-1) COD and 30 mg L(-1) BOD5) and inorganic pollutants (e.g., up to 0.5 mg L(-1) Cu and 0.1 mg L(-1) Cd) in the receiving aquatic environments. Greenhouse experiments examining the effects of wastewater reuse on food plants such as tomato, lettuce, and radish showed that the treated effluent adversely affected plant growth, photosynthesis, and antioxidant enzyme contents. However, the pollution burden and biological effects on plants were substantially reduced by using a 50 % dilution of treated sewage effluent, suggesting the potential of reusing treated effluent in agriculture so long as appropriate monitoring and control is in place.

  7. Effect of Treated Wastewater Irrigation on Heavy Metals Distribution in a Tunisian Soil

    Directory of Open Access Journals (Sweden)

    K. Khaskhoussy

    2015-06-01

    Full Text Available Treated wastewater (TWW may contain toxic chemical constituents that pose negative environmental and health impacts. In this study, soil samples under treated wastewater irrigation were studied. For this purpose, six plots were made in an irrigated area in north of Tunisia and treated with two water qualities: fresh water (FW and treated wastewater (TWW. Five soil depths were used: 0-30, 30-60, 60-90, 90-120 and 120-150 cm. The TWW irrigation increased significantly (P≤0.05 the soils’ EC, Na, K, Ca, Mg, Cl, SAR, Cu, Cd and Ni and had no significant (P ≤0.05 effect on the soils’ pH, Zn, Co and Pb contents. EC, Na, Cl, SAR, Zn and Co increased significantly with soil depth. The results for K, Ca, Mg, Cd, Pb and Ni exhibited similar repartition in different layers of soil. It was also shown that the amount of different elements in soil irrigated with fresh water (FW were less compared with the control soil

  8. Performance evaluation of full scale UASB reactor in treating stillage wastewater

    OpenAIRE

    A.Mirsepasi , H. R. Honary , A. R. Mesdaghinia, A. H. Mahvi , H. Vahid , H. Karyab

    2006-01-01

    Upflow anaerobic sludge blanket (UASB) reactors have been widely used for treatment of industrial wastewater. In this study two full-scale UASB reactors were investigated. Volume of each reactor was 420 m3. Conventional parameters such as pH, temperature and efficiency of COD, BOD, TOC removal in each reactor were investigated. Also several initial parameters in designing and operating of UASB reactors, such as upflow velocity, organic loading rate (OLR) and hydraulic retention time were inve...

  9. ECOLOGICAL LIFE CYCLE ASSESSMENT OF MODIFIED NOVOLAKS WASTE USED IN INDUSTRIAL WASTEWATER TREATMENT

    Directory of Open Access Journals (Sweden)

    Wioletta M. BAJDUR

    2017-06-01

    Full Text Available Ecological Life Cycle Assessment (LCA applied in the assessment of the impact of products on the environment is a technique that allows for the evaluation of the environmental impact of polymeric flocculants used in industrial wastewater treatment. The possibility of conducting a full life cycle and thus manufacturing process analysis allows for reliable and accurate identification of the sources of environmental hazards and the impact of new products on the environment. Newly synthesized waste-based polymers are water soluble and possess the properties of flocculants, while reducing the parameters in industrial wastewater. In the paper, there are presented the results of the analysis conducted using LCA technique for the assessment of the impact of modified waste phenol formaldehyde resin (Novolak on the environment. LCA technique was used to assess the impact of the new flocculant applied in the process of metallurgical wastewater treatment taking into account the environmental impact of the flocculant manufacturing process.

  10. Application of ozonation process in industrial wastewaters: textile, kraft E1 and whey effluents.

    Science.gov (United States)

    Assalin, M R; Almeida, E S; Rosa, M A; Moraes, S G; Duran, N

    2004-08-01

    A large variety of organic and inorganic compounds can be found in wastewater from industrial processes. In this work, Advanced Oxidative Processes (AOPs) have been applied for the control of water pollution and the ozonation of different effluents was investigated. Wastewater from textile, kraft E1 and cheese manufacturing processes were chosen as examples of industrial effluents. The efficiency of substrate mineralization has been comparatively analyzed by the decrease in total organic carbon (TOC), color, and toxicity. The results revealed that the ozonation process can be a method for decolorization of effluent, but it is not effective for TOC reduction. The whey effluent was the most recalcitrant wastewater for ozone treatment which produced no TOC removal.

  11. Evaluation of Wastewater Treatment of Detergent Industry Using Coagulation Procession Pilot Scale

    Directory of Open Access Journals (Sweden)

    MR Shahmansouri

    2005-04-01

    Full Text Available Introduction: Surfactant or surface active agents are slightly soluble in water and cause foaming in waste treatment plants and also in the surface waters into which the waste effluent is discharged. During aeration of wastewater, these compounds collect on the surface of the water bubbles and create some problems in waste treatment. Methods: In this study, surfactant, turbidity and COD in the industrial wastewater of the company, Paksan was studied. Study was done at pH ranging between 2 and 13 in a pilot scale process. Results: The results showed that ferric chloride has higher efficiency in removal and it is possible to decrease the surfactant, turbidity and COD Conclusion: The efficiency of ferric chloride in coagulation process for removal of surfactant, turbidity and COD from industrial wastewater is better than ALUM, Lime and Ferric Sulfate,

  12. Seasonal changes in quality of wastewater from fruit and vegetable industry

    Science.gov (United States)

    Puchlik, Monika; Ignatowicz, Katarzyna

    2017-11-01

    The paper aimed at evaluating the seasonal changes in quality of wastewater from facilities producing fruit and vegetable juices, processed and frozen products, and vegetable concentrates. The study revealed that wastewater from fruit and vegetable industry contain large amounts of organic substances expressed as BOD5 (minimum - 500 mgO2/dm3, maximum - 6 100 mgO2/dm3) and COD (minimum - 806 mg O2/dm3, maximum - 7 732 mg O2/dm3), while is deficient in nitrogen and phosphorus. Considerable seasonal oscillations in sewage load disposed by industry to sewerage, were observed. An increase of 50%-60% wastewater concentrations was found between June and October in 2013-2016 as compared to the remaining months.

  13. Process Integration Design Methods for Water Conservation and Wastewater Reduction in Industry. Part 3: Experience of Industrial Application

    DEFF Research Database (Denmark)

    Wenzel, Henrik; Dunn, Russell; Gottrup, Lene

    2002-01-01

    This paper is Part 3 in a three part series of papers addressing operational techniques for applying mass integration principles to design in industry with special focus on water conservation and wastewater reduction. The presented techniques derive from merging US and Danish experience...... with industrial applications of process integration, as a result of a recently established co-operation between the US companies Solutia Inc., Cleaner Process Technologies Inc., and McSwain Engineering Inc. and the Technical University of Denmark. Parts 1 and 2 covered design techniques for any number...... of wastewater streams containing single and multiple contaminants respectively. Part 3 in this series presents experience from applying methods in industry and also illustrates the work related to each of the steps of the methods and discusses the benefits from the insights provided by each step. The presented...

  14. Water quality improvement of treated wastewater by intermittent soil percolation.

    Science.gov (United States)

    Castillo, G; Mena, M P; Dibarrart, F; Honeyman, G

    2001-01-01

    Our research aimed to evaluate intermittent soil infiltration of treated sewage for reuse in the north of Chile. Aerated lagoon effluent was infiltrated in columns packed with native soils (sandy-lime, lime-gravel and limey-sand). Columns were operated for more than a year under different cycles of filling and drying, depths and load pressures depending on soil characteristics. The efficiency of the system was determined through influent-effluent microbiological indicators level (faecal coliforms, E. coli, Salmonella spp, MS2 phage, and protozoan cysts), physicochemical characterisation (TOC, COD, BOD, nitrogen), and hydraulic flow measurement. Results showed: (a) high reduction of enteric bacteria (5-7 log10), some inactivation of phage (2-4 log10) and complete removal of intestinal cyst; (b) stable removal of organic matter (80-90% reduction of TOC, COD, BOD); and (c) partial ammonia reduction through adsorption and nitrification with denitrification mainly occurring in sandy soil. Preliminary data from pilot plant working in the field showed better results that those obtained in the laboratory especially removal of microbiological indicators. Microbiological quality of effluent met Class A regulations for agricultural reuse (WHO, 1989) and the system looks like an attractive alternative to cope with water shortage in the region.

  15. WASTEWATER

    African Journals Online (AJOL)

    ABSTRACT. The chemical degradation oflignin-rich kraft pulp wastewater was carried out by ozonation process followed by biological treatment using activated sludge. The effects of pH on the degradation of lignin and the production of organic acids were examined experimentally in the ozonolysis of wastewater.

  16. City of Richland 300 Area industrial wastewater permit application

    International Nuclear Information System (INIS)

    1995-05-01

    Battelle-Pacific Northwest Labs and Westinghouse Hanford Co. are responsible for operating most of the facilities within the 300 Area; other contractors are also involved. The document gives briefly water/wastewater data: water sources, water usage, water discharge/loss, NPDES permit status, plant sewer outlets size and flow, etc. The document also includes the following attachments: 300 Area building list, Oct. 1993-Oct. 1994 300 Area water balance, waste shipments for CY 1994, complete chemical listing, sanitary sewer sampling results (12/19/94, 1/18/95, 1/15/95), and priority pollutant listings

  17. Environmental sustainability of the solar photo-Fenton process for wastewater treatment and pharmaceuticals mineralization at semi-industrial scale.

    Science.gov (United States)

    Foteinis, Spyros; Monteagudo, Jose Maria; Durán, Antonio; Chatzisymeon, Efthalia

    2018-01-15

    The environmental sustainability of a semi-industrial solar photo-Fenton reactor, treating real effluents emanating from a pharmaceutical laboratory, is assessed herein. The life cycle assessment/analysis (LCA) methodology was employed and real life cycle inventory (LCI) data was collected from a ferrioxalate-assisted homogeneous solar photo-Fenton wastewater treatment plant (WWTP), at Ciudad Real, Spain. Electricity was provided by photovoltaic (PV) panels in tandem with a battery bank, making the plant autonomous from the local grid. The effective treatment of 1m 3 of secondary-treated pharmaceutical wastewater, containing antipyrine, was used as a functional unit. The main environmental hotspot was identified to be the chemical reagents used to enhance treatment efficiency, mainly hydrogen peroxide (H 2 O 2 ) and to a smaller degree oxalic acid. On the other hand, land use, PV panels, battery units, compound parabolic collectors (CPC), tanks, pipes and pumps, as materials, had a low contribution, ranging from as little as 0.06% up to about 2% on the total CO 2eq emissions. Overall, the solar photo-Fenton process was found to be a sustainable technology for treating wastewater containing micropollutants at semi-industrial level, since the total environmental footprint was found to be 2.71kgCO 2 m -3 or 272mPtm -3 , using IPCC 2013 and ReCiPe impact assessment methods, respectively. A sensitivity analysis revealed that if the excess of solar power is fed back into the grid then the total environmental footprint is reduced. Depending on the amount of solar power fed back into the grid the process could have a near zero total environmental footprint. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A sensitive ferricyanide-mediated biochemical oxygen demand assay for analysis of wastewater treatment plant influents and treated effluents.

    Science.gov (United States)

    Jordan, Mark A; Welsh, David T; John, Richard; Catterall, Kylie; Teasdale, Peter R

    2013-02-01

    Representative and fast monitoring of wastewater influent and effluent biochemical oxygen demand (BOD) is an elusive goal for the wastewater industry and regulatory bodies alike. The present study describes a suitable assay, which incorporates activated sludge as the biocatalyst and ferricyanide as the terminal electron acceptor for respiration. A number of different sludges and sludge treatments were investigated, primarily to improve the sensitivity of the assay. A limit of detection (LOD) (2.1 mg BOD₅ L⁻¹) very similar to that of the standard 5-day BOD₅ method was achieved in 4 h using raw influent sludge that had been cultured overnight as the biocatalyst. Reducing the microbial concentration was the most effective means to improve sensitivity and reduce the contribution of the sludge's endogenous respiration to total ferricyanide-mediated (FM) respiration. A strong and highly significant relationship was found (n = 33; R = 0.96; p < 0.001; slope = 0.94) between BOD₅ and FM-BOD equivalent values for a diverse range of samples including wastewater treatment plant (WWTP) influent and treated effluent, as well as several grey water samples. The activated sludge FM-BOD assay presented here is an exceptional surrogate method to the standard BOD₅ assay, providing representative, same-day BOD analysis of WWTP samples with a comparable detection limit, a 4-fold greater analytical range and much faster analysis time. The industry appeal of such an assay is tremendous given that ~90% of all BOD₅ analysis is dedicated to measurement of WWTP samples, for which this assay is specifically designed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Algal-based immobilization process to treat the effluent from a secondary wastewater treatment plant (WWTP)

    International Nuclear Information System (INIS)

    He Shengbing; Xue Gang

    2010-01-01

    Algal-based immobilization process was applied to treat the effluent from a secondary wastewater treatment plant. Batch test proved that algae could attach onto fiber-bundle carrier in 7 days, and then the algal-based immobilization reactor could reduce TN (total nitrogen) and TP (total phosphorus) significantly within 48 h. Based on the above investigations, the hydraulic retention time (HRT) of the algal-based immobilization reactor in continuous operation mode was determined to be 2 days. During the 91 days of experiment on the treating secondary effluent of Guang-Rao wastewater treatment plant, it was found that the fiber-bundle carrier could collect the heterobacteria and nitrifying bacteria gradually, and thus improved the COD removal efficiency and nitrification performance step by step. Results of the continuous operation indicated that the final effluent could meet the Chinese National First A-level Sewage Discharge Standard when the algal-based immobilization reactor reached steady state.

  20. Retention in Treated Wastewater Affects Survival and Deposition of Staphylococcus aureus and Escherichia coli in Sand Columns

    NARCIS (Netherlands)

    Li, Jiuyi; Zhao, Xiaokang; Tian, Xiujun; Li, Jin; Sjollema, Jelmer; Wang, Aimin

    The fate and transport of pathogenic bacteria from wastewater treatment facilities in the Earth's subsurface have attracted extensive concern over recent decades, while the impact of treated-wastewater chemistry on bacterial viability and transport behavior remains unclear. The influence of

  1. Preparation of Cathode-Anode Integrated Ceramic Filler and Application in a Coupled ME-EGSB-SBR System for Chlortetracycline Industrial Wastewater Systematic Treatment

    OpenAIRE

    Qi, Yuanfeng; Wu, Suqing; Xi, Fei; He, Shengbing; Fan, Chunzhen; Dai, Bibo; Huang, Jungchen; Meng, Meng; Zhu, Xiangguo; Wang, Lei

    2016-01-01

    Chlortetracycline (CTC) contamination of aquatic systems has seriously threatened the environmental and human health throughout the world. Conventional biological treatments could not effectively treat the CTC industrial wastewater and few studies have been focused on the wastewater systematic treatment. Firstly, 40.0 wt% of clay, 30.0 wt% of dewatered sewage sludge (DSS), and 30.0 wt% of scrap iron (SI) were added to sinter the new media (cathode-anode integrated ceramic filler, CAICF). Subs...

  2. Pilot-scale testing membrane bioreactor for wastewater reclamation in industrial laundry

    DEFF Research Database (Denmark)

    Andersen, Martin; Kristensen, Gert Holm; Brynjolf, M.

    2002-01-01

    A pilot-scale study of membrane bioreactor treatment for reclamation of wastewater from Berendsen Textile Service industrial laundry in Søborg, Denmark was carried out over a 4 month period. A satisfactory COD degradation was performed resulting in a low COD in the permeate (

  3. Evaluation of an ASM1 Model Calibration Precedure on a Municipal-Industrial Wastewater Treatment Plant

    DEFF Research Database (Denmark)

    Petersen, Britta; Gernaey, Krist; Henze, Mogens

    2002-01-01

    The purpose of the calibrated model determines how to approach a model calibration, e.g. which information is needed and to which level of detail the model should be calibrated. A systematic model calibration procedure was therefore defined and evaluated for a municipal–industrial wastewater trea...

  4. ETV REPORT: EVALUATION OF HYDROMETRICS, INC., HIGH EFFICIENCY REVERSE OSMOSIS (HERO™) INDUSTRIAL WASTEWATER TREATMENT SYSTEM

    Science.gov (United States)

    Hydrometrics, founded in 1979 and located in Helena, MT, manufactures a commercial-ready High Efficiency Reverse Osmosis (HERO™) industrial wastewater treatment system. The system uses a three-stage reverse osmosis process to remove and concentrate metals for recovery while prod...

  5. Study on treatment of industrial wastewater with thorium by the liquid membrane emulsion technology

    International Nuclear Information System (INIS)

    Che Liping; Yu Yongfu; Yuan Jizu

    2005-01-01

    The enrichment of thorium from industrial wastewater with Th 4+ is studied by the liquid membrane emulsion technology of CCl 4 -N205-P204+TBP-HNO 3 . The conditions of making emulsion and the technological factors such as the ratios of oil to inner and water to emulsion, the pH and the extraction time are investigated. (authors)

  6. Bioaugmentation: An Emerging Strategy of Industrial Wastewater Treatment for Reuse and Discharge.

    Science.gov (United States)

    Nzila, Alexis; Razzak, Shaikh Abdur; Zhu, Jesse

    2016-08-25

    A promising long-term and sustainable solution to the growing scarcity of water worldwide is to recycle and reuse wastewater. In wastewater treatment plants, the biodegradation of contaminants or pollutants by harnessing microorganisms present in activated sludge is one of the most important strategies to remove organic contaminants from wastewater. However, this approach has limitations because many pollutants are not efficiently eliminated. To counterbalance the limitations, bioaugmentation has been developed and consists of adding specific and efficient pollutant-biodegrading microorganisms into a microbial community in an effort to enhance the ability of this microbial community to biodegrade contaminants. This approach has been tested for wastewater cleaning with encouraging results, but failure has also been reported, especially during scale-up. In this review, work on the bioaugmentation in the context of removal of important pollutants from industrial wastewater is summarized, with an emphasis on recalcitrant compounds, and strategies that can be used to improve the efficiency of bioaugmentation are also discussed. This review also initiates a discussion regarding new research areas, such as nanotechnology and quorum sensing, that should be investigated to improve the efficiency of wastewater bioaugmentation.

  7. Reuse of wastewater from pulp industry for the optimization of fungal xylanase production

    Directory of Open Access Journals (Sweden)

    Geisiany Maria de Queiroz-Fernandes

    2017-05-01

    Full Text Available The production of enzymes using agro-industrial waste is a low cost alternative for the reuse of byproducts, with the subsequent impact decrease on the environment. Current analysis produced xylanase using fungus Aspergillus niger, with two types of wastewater generated during the pulp chemical bleaching phase as inducers. Xylanase was produced by submerged liquid fermentation and factorial design optimized parameters that influence production (concentration of wastewater and production period. Initial culture conditions (pH, temperature and agitation were optimized independently. Alkaline wastewater was more effective than acidic wastewater for the induction of xylanase in optimized conditions: 50% of culture medium, 7-day production, 30°C, pH 6.0 and agitation at 160 rpm. Despite different results, acidic and alkaline wastewaters induced xylanase production by A. niger when employed in concentrations lower than or equal to 50% of culture medium and in the most optimal conditions described above. Alkaline wastewater is highlighted as the most efficient for such production.

  8. Perspectives on the feasibility of using microalgae for industrial wastewater treatment.

    Science.gov (United States)

    Wang, Yue; Ho, Shih-Hsin; Cheng, Chieh-Lun; Guo, Wan-Qian; Nagarajan, Dillirani; Ren, Nan-Qi; Lee, Duu-Jong; Chang, Jo-Shu

    2016-12-01

    Although microalgae can serve as an appropriate alternative feedstock for biofuel production, the high microalgal cultivation cost has been a major obstacle for commercializing such attempts. One of the feasible solution for cost reduction is to couple microalgal biofuel production system with wastewater treatment, as microalgae are known to effectively eliminate a variety of nutrients/pollutants in wastewater, such as nitrogen/phosphate, organic carbons, VFAs, pharmaceutical compounds, textile dye compounds, and heavy metals. This review aims to critically discuss the feasibility of microalgae-based wastewater treatment, including the strategies for strain selection, the effect of wastewater types, photobioreactor design, economic feasibility assessment, and other key issues that influence the treatment performance. The potential of microalgae-bacteria consortium for treatment of industrial wastewaters is also discussed. This review provides useful information for developing an integrated wastewater treatment with microalgal biomass and biofuel production facilities and establishing efficient co-cultivation for microalgae and bacteria in such systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Bioaugmentation: An Emerging Strategy of Industrial Wastewater Treatment for Reuse and Discharge

    Directory of Open Access Journals (Sweden)

    Alexis Nzila

    2016-08-01

    Full Text Available A promising long-term and sustainable solution to the growing scarcity of water worldwide is to recycle and reuse wastewater. In wastewater treatment plants, the biodegradation of contaminants or pollutants by harnessing microorganisms present in activated sludge is one of the most important strategies to remove organic contaminants from wastewater. However, this approach has limitations because many pollutants are not efficiently eliminated. To counterbalance the limitations, bioaugmentation has been developed and consists of adding specific and efficient pollutant-biodegrading microorganisms into a microbial community in an effort to enhance the ability of this microbial community to biodegrade contaminants. This approach has been tested for wastewater cleaning with encouraging results, but failure has also been reported, especially during scale-up. In this review, work on the bioaugmentation in the context of removal of important pollutants from industrial wastewater is summarized, with an emphasis on recalcitrant compounds, and strategies that can be used to improve the efficiency of bioaugmentation are also discussed. This review also initiates a discussion regarding new research areas, such as nanotechnology and quorum sensing, that should be investigated to improve the efficiency of wastewater bioaugmentation.

  10. Wastewater quality control at Sarnia (Ontario, Canada) petrochemical industries

    Energy Technology Data Exchange (ETDEWEB)

    Vianna, Arlinda C. [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil); Souza, Eliane S.; Himmelman, William [Lambton College, Sarnia, ON (Canada)

    1993-12-31

    Ontario industries are required by law to meet strict regulations under the provinces under MISA initiative (Municipal-Industrial Strategy for Abatement). The petroleum-petrochemical area was selected as a leader in the development of new environmental objectives, and monitoring and training programs. Sarnia has become a world leader in industrial environmental control systems and the approach toward zero emissions. 4 refs., 6 figs., 2 tabs.

  11. Parasitic and bacterial contamination in collards using effluent from treated domestic wastewater in Chiang Mai, Thailand.

    Science.gov (United States)

    Keawvichit, R; Wongworapat, K; Putsyainant, P; Silprasert, A; Karnchanawong, S

    2001-01-01

    Thailand often has inadequate water supply for agriculture during the dry season. The reuse of treated wastewater treatment plants could solve this problem. Treatment of domestic wastewater of Chiang Mai municipality by the aerated lagoon system (AL) releases more than 25,000 m3 of treated water everyday. The reuse of wastewater in agriculture is an efficient use of water, especially in tropical countries or in drought zones. The objective of this study is to demonstrate the possibility of using treated wastewater in growing edible vegetables, ie collards (kale), without pathogenic parasite and bacterial contamination. Collards (Brassica oleracea var acephala) were grown using either the treated wastewater from the aerated lagoon system (AL) or ground water (GW). Three cropping times were scheduled in February, May and July, 2000. Samples of water from AL system and GW were taken two times per month (the consecutive weeks) from February to July and examined for bacteria and parasites. Irrigation water (IW) that was normally used in agriculture was also collected, at the same time of the AL and GW collection, for bacteria and parasite investigation. A soil sample was taken before and after each crop for parasite examination. Collards were also collected at the end of the crop for parasite investigation. The results showed that GW seems to be a clean water since no pathogenic bacteria were found although small amount of Escherichia coli was noted in May. For AL and IW, similar number and types of bacteria were found. They were Aeromonas sobria, A. hydrophila, E. coli, Citrobacter freundii, Pseudomonas aeruginosa, non-pathogenic type of Vibrio cholerae. The small number of Salmonella enteritidis gr E was found in AL in April. After investigating 12 samples in 6 months of each kind of water, ie GW, Al, and IW, no parasite was found. Only unidentified free living nematodes were found in IW but those parasites are non pathogenic. A small number of unidentified free

  12. Combination of electroflotation process and down-flow granular filtration to treat wastewater contaminated with oil.

    Science.gov (United States)

    Nonato, Thyara Campos Martins; Schöntag, Juliana Marques; Burgardt, Tiago; Alves, Alcione Aparecida de Almeida; Broock, William Flores; Dalsasso, Ramon Lucas; Sens, Maurício Luiz

    2018-03-01

    One of the main problems faced by the oil industry is related to the amount of produced water generated during the oil extraction process. For proper disposal of this effluent, treatment processes should be applied to meet the requirements established by environmental agencies. Thus, the present study aimed to evaluate the efficiency of the combination of electroflotation process and down-flow granular filtration in the treatment of wastewater contaminated with oil. To this end, they were studied in a pilot system, to optimize the electroflotation process and combination of processes. The performance of the pilot system was determined by removal of oil and grease content (OG) in the treated effluent. According to the results, the electroflotation process had the best performance with an effluent input rate of 62 m 3  m -2  d -1 , current density of 80 A m -2 and NaCl concentration of 7900 mg L -1 . Under these conditions, the mean removal of OG from synthesized solution after 720 minutes of treatment was 86.64% (59.51 mg L -1 ) for the electroflotation process and 61.52% (12.91 mg L -1 ) after down-flow granular filtration. By combining the processes studied, we obtained an initial OG removal (470.55 mg L -1 ) of over 98% (6.42 mg L -1 ) in 720 minutes of treatment, with an energy consumption of the electrochemical reactor of 1.47 kWh m -3 . ANOVA: analysis of variance; CCRD: Central Composite Rotational Delineation; DOC: dissolved organic carbon; DSA: dimensionally stable anodes; LAPOA: Laboratory of Water Potabilization; OG: oil and grease; OPER: operating parameters of the electrochemical reactor; TDS: total dissolved solids; UFSC: Federal University of Santa Catarina.

  13. 2000-2001 creation of expertise and engineering technology of environment and energy project for anaerobic digestion of multiple kinds of organic industrial wastewater in China

    Energy Technology Data Exchange (ETDEWEB)

    Wu Libin [China Biogas Society (CBS) (China). Dept. of International Affairs

    2001-07-01

    Environmental protection is the basic policy of China. It has been proved by both of Chinese and world's development practice that the contradictions between development and environment must be well solved so as to realize sustainable development. Much concern has been paid on the research and development of technology on biogas (anaerobic digestion) to treat wastewater by China in last two decades, in addition with international influence and promotion from environment and development, the trend of anaerobic digestion development shows rapidly sign. Biogas technology has a wide field and good market for its implementation in China. Some environment and energy projects for anaerobic digestion of multiple kinds of organic industrial wastewater obtained fine benefits in pollution control, cleaner energy recovery and sustainable economic growth. However, the potentiality for market exploration is still higher. This paper presented the Chinese explorative research and successive design and anaerobic digestion project case studies on some 50 sorts of organic industrial wastewater, which are hard to biodegrade, hazardous, non-hygienic and chemical, e.g. alkali method straw pulp and chemical pulp-paper making wastewater, wastewater form medical industry, biopharmaceutical production, antibiotics as penicillin, erythromycin etc. Chinese medical herbs processing, antibiotics, tanning, brewery, distillery, agricultural chemicals, pesticide and insecticide, animal medicine, dyeing production, textile and printing industry, petroleum-chemical processing (PTA-phenyl terephthalic acid), coke processing, explosive production as RDX, hospitals, can and food processing, sugar-processing, municipal sewage with mixed industrial and domestic wastewater etc. All the mentioned research and practice show that both Chinese people and Chinese government have made great efforts in the last two decades in purifying the environment of water, soil and atmosphere via combining good

  14. Biodegradability of pharmaceutical compounds in agricultural soils irrigated with treated wastewater

    International Nuclear Information System (INIS)

    Grossberger, Amnon; Hadar, Yitzhak; Borch, Thomas; Chefetz, Benny

    2014-01-01

    Pharmaceutical compounds (PCs) are introduced into agricultural soils via irrigation with treated wastewater (TWW). Our data show that carbamazepine, lamotrigine, caffeine, metoprolol, sulfamethoxazole and sildenafil are persistent in soils when introduced via TWW. However, other PCs, namely diclofenac, ibuprofen, bezafibrate, gemfibrozil and naproxen were not detected in soils when introduced via TWW. This is likely due to rapid degradation as confirmed in our microcosm studies where they exhibited half-lives (t 1/2 ) between 0.2–9.5 days when soils were spiked at 50 ng/g soil and between 3 and 68 days when soils were spiked at 5000 ng/g soil. The degradation rate and extent of PCs observed in microcosm studies were similar in soils that had been previously irrigated with TWW or fresh water. This suggests that pre-exposure of the soils to PCs via irrigation with TWW does not enhance their biodegradation. This suggests that PCs are probably degraded in soils via co-metabolism. Highlights: • Some pharmaceuticals are highly persistent in arable soils. • Weak acid pharmaceuticals are readily degradable in agricultural soils. • Irrigation with treated wastewater does not enhance degradation of pharmaceuticals. • Degradation of pharmaceuticals in soil is probably occurred via co-metabolism. -- Some pharmaceutical compounds are persistent in arable soils when introduced via irrigation with treated wastewater

  15. Integration of coagulation and electro-activated HSO5− to treat pulp and paper wastewater

    Directory of Open Access Journals (Sweden)

    Nematollah Jaafarzadeh

    2017-09-01

    Full Text Available Pulp and paper wastewater (PPW is classified as complex wastewater that contains high concentrations of recalcitrant pollutants. In this study, the integration of coagulation process and electro-activated peroxymonosulfate (PMS were tested to treat PPW. FeCl3, aluminum sulfate and poly aluminum chloride were examined for chemical oxygen demand (COD removal from PPW. Amongst the coagulants, FeCl3 showed higher performance compared to other coagulants in which 55% of COD was removed under the conditions of natural pH of 6.9 and FeCl3 dosage of 100 mg L−1. Coagulation-treated wastewater by FeCl3 was treated by electro-activated PMS. Under the condition of 0.75 mA cm−2 current density, 6.0 mM PMS and 60 min reaction time, 53% of COD was further eliminated. To compare with electro-Fenton, electro-activated PMS provided higher COD removal and specific oxidant efficiency. Integration of coagulation (FeCl3 and electro-activated PMS enhanced the biodegradability of PPW based on biochemical oxygen demand/COD index. The results showed that integrated chemical and electrochemical processes can be used as a pretreatment for biological process.

  16. Solutions for the disposal of industrial and rain wastewater of transport enterprises in Moscow

    OpenAIRE

    Varyushina Galina

    2018-01-01

    The article gives results of the surveys water management systems, auto repair companies, bus compamies, taxis, fleets of trucks, production and technical enterprises. Studied technological processes of primary production: cleaning engines, flushing of radiators and parts of batteries, testing of fuel tanks, cleaning of parts and units, exterior washing and painting of motor vehicles. There were carried out field examinations of local industrial wastewater treatment facilities industrial wast...

  17. Isolation, Identification, and Characterization of Cadmium Resistant Pseudomonas sp. M3 from Industrial Wastewater

    OpenAIRE

    Syed Zaghum Abbas; Mohd Rafatullah; Norli Ismail; Japareng Lalung

    2014-01-01

    The present study deals with the isolation, identification, and characterization of the cadmium resistant bacteria from wastewater collected from industrial area of Penang, Malaysia. The isolate was selected based on high level of the cadmium and antibiotic resistances. On the basis of morphological, biochemical characteristics, 16S rDNA gene sequencing and phylogeny analysis revealed that the strain RZCd1 was authentically identified as Pseudomonas sp. M3. The industrial isolate showed more ...

  18. Preparation of Cathode-Anode Integrated Ceramic Filler and Application in a Coupled ME-EGSB-SBR System for Chlortetracycline Industrial Wastewater Systematic Treatment

    Directory of Open Access Journals (Sweden)

    Yuanfeng Qi

    2016-01-01

    Full Text Available Chlortetracycline (CTC contamination of aquatic systems has seriously threatened the environmental and human health throughout the world. Conventional biological treatments could not effectively treat the CTC industrial wastewater and few studies have been focused on the wastewater systematic treatment. Firstly, 40.0 wt% of clay, 30.0 wt% of dewatered sewage sludge (DSS, and 30.0 wt% of scrap iron (SI were added to sinter the new media (cathode-anode integrated ceramic filler, CAICF. Subsequently, the nontoxic CAICF with rough surface and porous interior packed into ME reactor, severing as a pretreatment step, was effective in removing CTC residue and improving the wastewater biodegradability. Secondly, expanded granular sludge bed (EGSB and sequencing batch reactor (SBR, serving as the secondary biological treatment, were mainly focusing on chemical oxygen demand (COD and ammonia nitrogen (NH3-N removal. The coupled ME-EGSB-SBR system removed about 98.0% of CODcr and 95.0% of NH3-N and the final effluent met the national discharged standard (C standard of CJ 343-2010, China. Therefore, the CTC industrial wastewater could be effectively treated by the coupled ME-EGSB-SBR system, which has significant implications for a cost-efficient system in CTC industrial systematic treatment and solid wastes (DSS and SI treatment.

  19. Chemical coagulants and Moringa oleifera seed extract for treating concrete wastewater

    Directory of Open Access Journals (Sweden)

    Heber Martins de Paula

    2016-01-01

    Full Text Available Wastewater from concrete plants has a high pH and a high concentration of suspended solids, necessitating treatment before reuse or discharge into the environment. The objective of this study is to evaluate the efficiency of two chemical coagulants, aluminum sulfate (Al2(SO43 and iron chloride (FeCl3, and a natural coagulant, Moringa oleifera (MO, all in their soluble forms, in the treatment of wastewater from concrete plants. To this end, the efficiencies of the three coagulants, in combinations with different proportions, were tested. The quality parameters of the wastewater obtained after the treatments were compared to the limit values for non-potable water. The use of coagulants in their soluble form potentiates their effect, especially when preparing the MO extract, i.e., greater amounts of the protein responsible for the coagulation is extracted. A mixture with MO and Al2(SO43 in a 20:80 proportion showed the best results, with 97.5% of the turbidity removed at 60 min. of sedimentation, allowing the treated water to be used for washing vehicles and flushing toilets. The FeCl3 treatment produced a high concentration of chlorides, which could cause corrosion problems, and is therefore not recommended for concrete wastewater treatment.

  20. Efficiency of a Bed Biofilm Reactor Using a LECA Carrier to Treat Hospital Wastewater

    Directory of Open Access Journals (Sweden)

    Reza Shokoohi

    2016-03-01

    Full Text Available Hospital wastewater is of great environmental concern because it contains a variety of hazardous microbial and chemical substances. This study aims to investigate the efficiency of a moving bed biofilm reactor (MBBR with a light expanded clay aggregate (LECA carrier for treating hospital wastewater. This pilot study used a Plexiglas reactor that had a volume of 100 L, a continuous up-flow hydraulic regime, and a LECA carrier to test removal of chemical oxygen demand (COD from wastewater in a public hospital. To assess MBBR efficiency, the study used retention times of 8, 12, and 24 hours, filling percentages of 30% and 50%, and mixed liquor suspended solids (MLSSs of 1000, 3000, and 5000 mg/L. The results indicated that using a single LECA carrier in an MBBR system was not sufficient to remove organic materials from hospital wastewater, because the carrier could not be completely suspended. After some modifications, consisting mainly of returning activated sludge, the system was 83% efficient at removing COD using a LECA carrier at a retention time of 24 hours, with 50% filling, and 5000 mg/L of MLSS.

  1. Phenotypic properties and microbial diversity of methanogenic granules from a full-scale UASB reactor treating brewery wastewater

    NARCIS (Netherlands)

    Diaz, E.E.; Stams, A.J.M.; Amils, R.; Sanz, J.L.

    2006-01-01

    Methanogenic granules from an anaerobic bioreactor that treated wastewater of a beer brewery consisted of different morphological types of granules. In this study, the microbial compositions of the different granules were analyzed by molecular microbiological techniques: cloning, denaturing gradient

  2. [Complex technology for water and wastewater disinfection and its industrial realization in prototype unit].

    Science.gov (United States)

    Arakcheev, E N; Brunman, V E; Brunman, M V; Konyashin, A V; Dyachenko, V A; Petkova, A P

    Usage of complex automated electrolysis unit for drinking water disinfection and wastewater oxidation and coagulation is scoped, its ecological and energy efficiency is shown. Properties of technological process of anolyte production using membrane electrolysis of brine for water disinfection in municipal pipelines and potassium ferrate production using electrochemical dissolution of iron anode in NaOH solution for usage in purification plants are listed. Construction of modules of industrial prototype for anolyte and ferrate production and applied aspects of automation of complex electrolysis unit are proved. Results of approbation of electrolytic potassium ferrate for drinking water disinfection and wastewater, rain water and environmental water oxidation and coagulation are shown.

  3. Electrolysis of polluting wastes: I - Wastewater from a seasoning freeze-drying industry

    OpenAIRE

    Angelis, Dejanira F. de; Corso, Carlos R.; Bidoia, Ederio D.; Moraes, Peterson B.; Domingos, Roberto N.; Rocha-Filho, Romeu C.

    1998-01-01

    Wastewater from a seasoning freeze-drying industry was electrolysed to increase its biodegradability. Stainless-steel electrodes were used at 9.09 A/m², for up to 80 min. Conductivity, pH, biochemical (BOD) and chemical (COD) oxygen demands, Daphnia similis acute toxicity bioassays, and bacteria counting through the plate count agar method were determined after different times of electrolysis. The results (e.g. higher BOD and lower COD) showed that the biodegradability of the wastewater was s...

  4. A Survey of domestic and industrial wastewater application in south Tehran agricultural land

    International Nuclear Information System (INIS)

    Torabian, A.; Baghouri, E.

    1997-01-01

    Total and available amounts of Cd, Ni, Zn, Pb, and Cu have been measured in the soil and plants samples of southern Tehran agricultural land for three years. These areas are irrigated by domestic and industrial wastewater. Results of this study indicate that concentrations of these metals are higher than control samples, taken from untreated lands. Due to concentration of these elements in tissues of vegetables consume by the residents of Tehran. Therefore, it is recommended that the use of wastewater for irrigation to be halted

  5. Supported noble metal catalysts in the catalytic wet air oxidation of industrial wastewaters and sewage sludges.

    Science.gov (United States)

    Besson, M; Descorme, C; Bernardi, M; Gallezot, P; di Gregorio, F; Grosjean, N; Minh, D Pham; Pintar, A

    2010-12-01

    This paper reviews some catalytic wet air oxidation (CWAO) investigations of industrial wastewaters over platinum and ruthenium catalysts supported on TiO2 and ZrO2 formulated to be active and resistant to leaching, with particular focus on the stability of the catalyst. Catalyst recycling experiments were performed in batch reactors and long-term stability tests were conducted in trickle-bed reactors. The catalyst did not leach upon treatment of Kraft bleaching plant and olive oil mill effluents, and could be either recycled or used for long periods of time in continuous reactors. Conversely, these catalysts were rapidly leached when used to treat effluents from the production of polymeric membranes containing N,N-dimethylformamide. The intermediate formation of amines, such as dimethylamine and methylamine with a high complexing capacity for the metal, was shown to be responsible for the metal leaching. These heterogeneous catalysts also deactivated upon CWAO of sewage sludges due to the adsorption of the solid organic matter. Pre-sonication of the sludge to disintegrate the flocs and improve solubility was inefficient.

  6. A chemically enhanced biological process for lowering operative costs and solid residues of industrial recalcitrant wastewater treatment.

    Science.gov (United States)

    Di Iaconi, Claudio; Del Moro, Guido; De Sanctis, Marco; Rossetti, Simona

    2010-06-01

    An innovative process based on ozone-enhanced biological degradation, carried out in an aerobic granular biomass system (SBBGR--Sequencing Batch Biofilter Granular Reactor), was tested at pilot scale for tannery wastewater treatment chosen as representative of industrial recalcitrant wastewater. The results have shown that the process was able to meet the current discharge limits when the biologically treated wastewater was recirculated through an adjacent reactor where a specific ozone dose of 120 mg O3/L(influent) was used. The benefits produced by using ozone were appreciable even visually since the final effluent of the process looked like tap water. In comparison with the conventional treatment, the proposed process was able to reduce the sludge production by 25-30 times and to save 60% of operating costs. Molecular in situ detection methods were employed in combination with the traditional measurements (oxygen uptake rate, total protein content, extracellular polymeric substances and hydrophobicity) to evaluate microbial activity and composition, and the structure of the biomass. A stable presence of active bacterial populations was observed in the biomass with the simultaneous occurrence of distinctive functional microbial groups involved in carbon, nitrogen and sulphate removal under different reaction environments established within the large microbial aggregates. The structure and activity of the biomass were not affected by the use of ozone. 2010 Elsevier Ltd. All rights reserved.

  7. Potential use of industrial wastewater in irrigation - case study of ...

    African Journals Online (AJOL)

    4, Cl, K, heavy metals and trace elements. Results indicate that majority of the effluents from these industries have high relative conformity with irrigation water because of their relative conformity with FAO recommended (FAO 1992) standards.

  8. Toxicity screening of industrial wastewater in the Odra river basin

    OpenAIRE

    Källqvist, T.; Soldan, P.

    1993-01-01

    The effluents from 24 major industries in the Odra river catchment have been characterised as regards toxicity to fresh water organisms and chemical composition. Toxicity screening included tests with bacteria, algae, crustacean and fish. Three effluents with particulary high toxic potential have been identified. Certain other industries with less toxic effluents or small discharge volumes may also be of concern because of low dilution capacities in the receiving waters. Heavy metals have bee...

  9. Successional development of biofilms in moving bed biofilm reactor (MBBR) systems treating municipal wastewater.

    Science.gov (United States)

    Biswas, Kristi; Taylor, Michael W; Turner, Susan J

    2014-02-01

    Biofilm-based technologies, such as moving bed biofilm reactor (MBBR) systems, are widely used to treat wastewater. Biofilm development is important for MBBR systems as much of the microbial biomass is retained within reactors as biofilm on suspended carriers. Little is known about this process of biofilm development and the microorganisms upon which MBBRs rely. We documented successional changes in microbial communities as biofilms established in two full-scale MBBR systems treating municipal wastewater over two seasons. 16S rRNA gene-targeted pyrosequencing and clone libraries were used to describe microbial communities. These data indicate a successional process that commences with the establishment of an aerobic community dominated by Gammaproteobacteria (up to 52 % of sequences). Over time, this community shifts towards dominance by putatively anaerobic organisms including Deltaproteobacteria and Clostridiales. Significant differences were observed between the two wastewater treatment plants (WWTPs), mostly due to a large number of sequences (up to 55 %) representing Epsilonproteobacteria (mostly Arcobacter) at one site. Archaea in young biofilms included several lineages of Euryarchaeota and Crenarchaeota. In contrast, the mature biofilm consisted entirely of Methanosarcinaceae (Euryarchaeota). This study provides new insights into the community structure of developing biofilms at full-scale WWTPs and provides the basis for optimizing MBBR start-up and operational parameters.

  10. Bacteriophages as indicators of human and animal faecal contamination in raw and treated wastewaters from Tunisia.

    Science.gov (United States)

    Yahya, M; Hmaied, F; Jebri, S; Jofre, J; Hamdi, M

    2015-05-01

    We aimed at quantifying bacteriophages in raw and treated wastewaters of human and animal origin in Tunisia to assess their usefulness for tracking the origin of faecal pollution and in the follow-up of effectiveness of water treatments process. The concentrations of bacteriophages in wastewater samples were determined by double layer agar technique. Somatic coliphages and F-specific RNA bacteriophages were present in all types of samples in high concentrations. The values of Escherichia coli were variable depending on geographical location. On the other hand, bacteriophages infecting strain GA17 were detected preferably when human faecal contamination was occurred. Bacteriophages appear as a feasible and widely applicable manner to detect faecal contamination in Tunisia. On the other hand, phages infecting GA17 could be good markers for tracking the origin of faecal pollution in the area studied. The reuse of treated wastewaters can be a solution to meet the needs of water in the geographical area of study. Bacteriophages seem to predict differently the presence of faecal contamination in water than bacterial indicators. Consequently, they can be a valuable additional tool to improve water resources management for minimizing health risks. © 2015 The Society for Applied Microbiology.

  11. Novel industrial wastewater treatment integrated with recovery of water and salt under a zero liquid discharge concept.

    Science.gov (United States)

    Rajamani, Sengodagounder

    2016-03-01

    Conventional industrial effluent treatment systems are designed to reduce biochemical oxygen demand (BOD), chemical oxygen demand (COD) but not total dissolved solids (TDS), mainly contributed by chlorides. In addition to the removal of TDS, it is necessary to recover water for reuse to meet the challenges of shortage of quality water. To recover water, the wastewater needs to be further treated by adopting treatment systems including microfilters, low pressure membrane units such as ultrafiltration (UF), membrane bioreactors (MBR), etc., for the application of reverse osmosis (RO) systems. By adopting the RO system, 75%-80% of quality water with industrial waste for reuse has become a reality. The membrane system has been used for different applications. It has become mandatory to achieve zero liquid discharge (ZLD) in many states in India and other countries such as Spain, China, etc., and resulted in development of new treatment technologies to suit the local conditions.

  12. Energy optimization of water and wastewater management for municipal and industrial applications conference

    Energy Technology Data Exchange (ETDEWEB)

    1980-08-01

    These proceedings document the presentations given at the Energy Optimization of Water and Wastewater Management for Municipal and Industrial Applications Conference, sponsored by the Department of Energy (DOE). The conference was organized and coordinated by Argonne National Laboratory. The conference focused on energy use and conservation in water and wastewater. The General Session also reflects DOE's commitment to the support and development of waste and wastewater systems that are environmentally acceptable. The conference proceedings are divided into two volumes. Volume 1 contains the General Session and Sessions 1 to 5. Volume 2 covers Sessions 6 to 12. Separate abstracts are prepared for each item within the scope of the Energy Data Base.

  13. Experimental and computational investigation of polyacrylonitrile ultrafiltration membrane for industrial oily wastewater treatment

    International Nuclear Information System (INIS)

    Adib Hooman; Hassanajili, Shadi; Sheikhi-Kouhsar, Mohammad Reza; Salahi, Abdolhamid; Mohammadi, Toraj

    2015-01-01

    An experimental study on separation of industrial oil from oily wastewater has been done. A polyacrylonitrile membrane with a molecular weight cut-off (MWCO) of 20 kDa was used and an outlet wastewater of API unit of Tehran refinery was employed. The main purpose of this study was to develop a support vector machine model for permeation flux decline and fouling resistance in a cross-flow hydrophilic polyacrylonitrile membrane during ultrafiltration. The operating conditions which have been applied to develop a support vector machine model were transmembrane pressure (TMP), operating temperature, cross flow velocity (CFV), pH values of oily wastewater, permeation flux decline and fouling resistance. The testing results obtained by the support vector machine models are in very good agreement with experimental data. The calculated squared correlation coefficients for permeation flux decline and fouling resistance were both 0.99. Based on the results, the support vector machine proved to be a reliable accurate estimation method

  14. Energy optimization of water and wastewater management for municipal and industrial applications conference

    Energy Technology Data Exchange (ETDEWEB)

    1980-08-01

    These proceedings document the presentations given at the Energy Optimization of Water and Wastewater Management for Municipal and Industrial Applications, Conference, sponsored by the Department of Energy (DOE). The conference was organized and coordinated by Argonne National Laboratory. The conference focused on energy use on conservation in water and wastewater. The General Session also reflects DOE's commitment to the support and development of waste and wastewater systems that are environmentally acceptable. The conference proceedings are divided into two volumes. Volume 1 contains the General Session and Sessions 1 to 5. Volume 2 covers Sessions 6 to 12. Separate abstracts are prepared for each item within the scope of the Energy Data Base.

  15. Biomass characteristics in three sequencing batch reactors treating a wastewater containing synthetic organic chemicals

    DEFF Research Database (Denmark)

    Hu, Z.Q.; Ferraina, R.A.; Ericson, J.F.

    2005-01-01

    The physical and biochemical characteristics of the biomass in three lab-scale sequencing batch reactors (SBR) treating a synthetic wastewater at a 20-day target solids retention time (SRT) were investigated. The synthetic wastewater feed contained biogenic compounds and 22 organic priming...... compounds, chosen to represent a wide variety of chemical structures with different N, P and S functional groups. At a two-day hydraulic retention time (HRT), the oxidation-reduction potential (ORP) cycled between -100 (anoxic) and 100mV (aerobic) in the anoxic/aerobic SBR, while it remained in a range...... of 126 +/- 18 and 249 +/- 18 mV in the aerobic sequencing batch biofilm reactor (SBBR) and the aerobic SBR reactor, respectively. A granular activated sludge with excellent settleability (SVI = 98 +/- 31 L mg(-1)) developed only in the anoxic/aerobic SBR, compared to a bulky sludge with poor settling...

  16. Performance and microbial community composition in a long-term sequential anaerobic-aerobic bioreactor operation treating coking wastewater.

    Science.gov (United States)

    Joshi, Dev Raj; Zhang, Yu; Tian, Zhe; Gao, Yingxin; Yang, Min

    2016-09-01

    The combined anaerobic-aerobic biosystem is assumed to consume less energy for the treatment of high strength industrial wastewater. In this study, pollutant removal performance and microbial diversity were assessed in a long-term (over 300 days) bench-scale sequential anaerobic-aerobic bioreactor treating coking wastewater. Anaerobic treatment removed one third of the chemical oxygen demand (COD) and more than half of the phenols with hydraulic retention time (HRT) of 42 h, while the combined system with total HRT of 114 h removed 81.8, 85.6, 99.9, 98.2, and 85.4 % of COD, total organic carbon (TOC), total phenols, thiocyanate, and cyanide, respectively. Two-dimensional gas chromatography with time-of-flight mass spectrometry showed complete removal of phenol derivatives and nitrogenous heterocyclic compounds (NHCs) via the combined system, with the anaerobic process alone contributing 58.4 and 58.6 % removal on average, respectively. Microbial activity in the bioreactors was examined by 454 pyrosequencing of the bacterial, archaeal, and fungal communities. Proteobacteria (61.2-93.4 %), particularly Betaproteobacteria (34.4-70.1 %), was the dominant bacterial group. Ottowia (14.1-46.7 %), Soehngenia (3.0-8.2 %), and Corynebacterium (0.9-12.0 %), which are comprised of phenol-degrading and hydrolytic bacteria, were the most abundant genera in the anaerobic sludge, whereas Thiobacillus (6.6-43.6 %), Diaphorobacter (5.1-13.0 %), and Comamonas (0.2-11.1 %) were the major degraders of phenol, thiocyanate, and NHCs in the aerobic sludge. Despite the low density of fungi, phenol degrading oleaginous yeast Trichosporon was abundant in the aerobic sludge. This study demonstrated the feasibility and optimization of less energy intensive treatment and the potential association between abundant bacterial groups and biodegradation of key pollutants in coking wastewater.

  17. Microbubble enhanced ozonation process for advanced treatment of wastewater produced in acrylic fiber manufacturing industry

    KAUST Repository

    Zheng, Tianlong

    2015-02-02

    This work investigated microbubble-ozonation for the treatment of a refractory wet-spun acrylic fiber wastewater in comparison to macrobubble-ozonation. CODcr, NH3-N, and UV254 of the wastewater were removed by 42%, 21%, and 42%, respectively in the microbubble-ozonation, being 25%, 9%, and 35% higher than the removal rates achieved by macrobubble-ozonation at the same ozone dose. The microbubbles (with average diameter of 45μm) had a high concentration of 3.9×105 counts/mL at a gas flow rate of 0.5L/min. The gas holdup, total ozone mass-transfer coefficient, and average ozone utilization efficiency in the microbubble-ozonation were 6.6, 2.2, and 1.5 times higher than those of the macrobubble-ozonation. Greater generation of hydroxyl radicals and a higher zeta potential of the bubbles were also observed in the microbubble ozonation process. The biodegradability of the wastewater was also significantly improved by microbubble-ozonation, which was ascribed to the enhanced degradation of alkanes, aromatic compounds, and the many other bio-refractory organic compounds in the wastewater. Microbubble-ozonation can thus be a more effective treatment process than traditional macrobubble-ozonation for refractory wastewater produced by the acrylic fiber manufacturing industry.

  18. California Food Processing Industry Wastewater Demonstration Project: Phase I Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Glen; Atkinson, Barbara; Rhyne, Ivin

    2009-09-09

    Wastewater treatment is an energy-intensive process and electricity demand is especially high during the utilities summer peak electricity demand periods. This makes wastewater treatment facilities prime candidates for demand response programs. However, wastewater treatment is often peripheral to food processing operations and its demand response opportunities have often been overlooked. Phase I of this wastewater demonstration project monitored wastewater energy and environmental data at Bell-Carter Foods, Inc., California's largest olive processing plant. For this monitoring activity the project team used Green Energy Management System (GEMS) automated enterprise energy management (EEM) technologies. This report presents results from data collected by GEMS from September 15, 2008 through November 30, 2008, during the olive harvest season. This project established and tested a methodology for (1) gathering baseline energy and environmental data at an industrial food-processing plant and (2) using the data to analyze energy efficiency, demand response, daily peak load management, and environmental management opportunities at the plant. The Phase I goals were to demonstrate the measurement and interrelationship of electricity demand, electricity usage, and water quality metrics and to estimate the associated CO{sub 2} emissions.

  19. OPTIMIZATION OF MOTOR VEHICLE INDUSTRIES WASTEWATER TREATMENT METHODS WITH THE AIM OF HEAVY METALS REMOVAL AND WATER REUSE IN PILOT SCALE

    Directory of Open Access Journals (Sweden)

    S. A. Mirbagheri, M. Salehi M

    2006-10-01

    Full Text Available The waste of motor vehicle industries is mainly the result of washing, coloring and various stages of chassis manufacturing, which include oil, grease, dyestuff, chromium, phosphate and other pollutants. In the present research, extended aeration activated sludge biological treatment plant is being considered and evaluated, for the removal of heavy metals and pollution load from industrial wastes and sanitary wastewaters, and on the pilot scale for optimization of waste treatment method for motor vehicle industries. To accomplish the pilot experiments, the natural waste of Bahman motor vehicle factory is used. Effective factors on efficient removal of heavy metals and pollution load such as concentration of biological mass (MLVSS, COD, BOD, pH in the extended aeration activated sludge biological treatment system, in different ratios of the mixing of industrial waste to sanitary wastewater have been experimented and evaluated. The performance of the above system, in the best of conditions, removes about 90% of pollution load and 65% of heavy metals existing in the industrial wastes. After analyzing the experiments, it is concluded that the removal of heavy metals through biological methods is possible and moreover it is feasible to biologically treat the mixing of motor vehicle industries effluent and sanitary wastewater up to the ratio of one to one, if guided exactly and scientifically.

  20. Salinity effect of irrigation with treated wastewater in basal soil respiration in SE of Spain

    Science.gov (United States)

    Morugan, A.; Garcia-Orenes, F.; Mataix-Solera, J.

    2012-04-01

    The use of treated wastewater for the irrigation of agricultural soils is an alternative to utilizing better-quality water, especially in semiarid regions where water shortage is a very serious problem. Wastewater use in agriculture is not a new practice, all over the world this reuse has been common practice for a long time, but the concept is of greater importance currently because of the global water crisis. Replacement of freshwater by treated wastewater is seen as an important conservation strategy contributing to agricultural production, substantial benefits can derive from using this nutrient-rich waste water but there can also be a negative impact. For this reason it is necessary to know precisely the composition of water before applying it to the soil in order to guarantee minimal impact in terms of contamination and salinization. In this work we have been studying, for more than three years, different parameters in calcareous soils irrigated with treated wastewater in an agricultural Mediterranean area located at Biar (Alicante, SE Spain), with a crop of grape (Vitis labrusca). Three types of waters were used for the irrigation of the soil: fresh water (control) (TC), and treated wastewater from secondary (T2) and tertiary treatment (T3). Three different doses of irrigation have been applied to fit the efficiency of the irrigation to the crop and soil type during the study period. A soil sampling was carried out every four months. We show the results of the evolution of basal soil respiration (BSR), and its relationship with other parameters. We observed a similar pattern of behavior for BSR between treatments, a decrease at the first eighteen months of irrigation and an increase at the end of study. In our study case, the variations of BSR obtained for all the treatments seem to be closely related to the dose and frequency of irrigation and the related soil wetting and drying cycles. However, the results showed a negative correlation between BSR and

  1. WASTEWATER MANAGEMENT IN MOLASSES BASED DISTILLERY INDUSTRY: A REVIEW

    OpenAIRE

    MR. DIGVIJAY B. DHAVALE,; MR. S. M. BHOSALE

    2017-01-01

    The present study reviews recent research works of waste water management techniques in distillery industry across India. The paper not only discusses need of waste water management but also existing methods of doing it. Paper also provides an insight for future reference application of the same

  2. Enzymatic recovery of platinum (IV) from industrial wastewater using ...

    African Journals Online (AJOL)

    highest hydrogen-dependent platinum (IV) reducing activity in the presence of hydrogenase and its physiological electron carrier, cytochrome c3. When the purified hydrogenase enzyme (with and without cytochrome c3) was used with the industrial effluent, containing 7.9 mg.l-1 platinum, only 10 – 15% recovery was noted ...

  3. Process Integration Design Methods for Water Conservation and Wastewater Reduction in Industry. Part 3: Experience of Industrial Application

    DEFF Research Database (Denmark)

    Wenzel, Henrik; Dunn, Russell; Gottrup, Lene

    2002-01-01

    This paper is Part 3 in a three part series of papers addressing operational techniques for applying mass integration principles to design in industry with special focus on water conservation and wastewater reduction. The presented techniques derive from merging US and Danish experience with indu......This paper is Part 3 in a three part series of papers addressing operational techniques for applying mass integration principles to design in industry with special focus on water conservation and wastewater reduction. The presented techniques derive from merging US and Danish experience...... with industrial applications of process integration, as a result of a recently established co-operation between the US companies Solutia Inc., Cleaner Process Technologies Inc., and McSwain Engineering Inc. and the Technical University of Denmark. Parts 1 and 2 covered design techniques for any number...... experience comprises application in small-scale batch productions in textile dyeing and laundering as well as large scale continuous productions in chemical industry, and it is documented that the methods are robust and independent of the volume and continuity/discontinuity of the production. Industry...

  4. Fungi from industrial tannins: potential application in biotransformation and bioremediation of tannery wastewaters.

    Science.gov (United States)

    Prigione, Valeria; Trocini, Bruno; Spina, Federica; Poli, Anna; Romanisio, Davide; Giovando, Samuele; Varese, Giovanna Cristina

    2018-03-18

    Tannins are a complex family of polyphenolic compounds, widely distributed in the plant kingdom where they act as growth inhibitors towards many microorganisms including bacteria, yeasts, and fungi. Tannins are one of the major components of tannery wastewaters and may cause serious environmental pollution. In the present study, four different tannins (the hydrolysable chestnut ellagitannin and tara gallotannin and the condensed quebracho and wattle tannins) were characterized from a mycological point of view with the aim of selecting fungal strains capable of growing in the presence of high tannin concentration and thus potentially useful in industrial biotransformations of these compounds or in the bioremediation of tannery wastewaters. A total of 125 isolates of filamentous fungi belonging to 10 species and four genera (Aspergillus, Paecilomyces, Penicillium, and Talaromyces) were isolated from the tannin industrial preparations. Miniaturized biotransformation tests were set up with 10 fungal strains and the high-performance liquid chromatography (HPLC) analysis pointed out a strong activity of all the tested fungi on both chestnut and tara tannins. Two strains (Aspergillus tubingensis MUT 990 and Paecilomyces variotii MUT 1125), tested against a real tannery wastewater, were particularly efficient in chemical oxygen demand (COD) and tannin removal (> 60%), with a detoxification above 74%. These results indicate that these fungi are potentially exploitable in the treatment of tannery wastewaters.

  5. Management of wastewater from soap and food industries: a case study.

    Science.gov (United States)

    el-Gohary, F A; Abo-Elela, S I; Ali, H I

    1987-10-01

    This paper presents the wastewater management of an industrial complex which produces different products, i.e. soap, perfume extract, macaroni, jam and juices. A continuous monitoring programme for departmental as well as final effluents was carried out for almost 3 months. Characterization of the composite wastewater from both soap and food processing plants indicated that the waste was highly contaminated with organic compounds as indicated by COD and BOD values. Moreover, effluent from the soap manufacturing plant contains significant concentrations of oil and grease amounting to 563 mg l-1. Soap manufacturing effluent and the combined wastes discharged from the whole industrial complex were subjected to different treatment processes, namely dissolved air flotation, chemical coagulation-sedimentation, and biological treatment via a completely mixed activated sludge process. Although coagulation using alum followed by sedimentation removed 52% of COD, residual values did not comply with the regulatory standards. Biological treatment of the composite combined wastewater significantly removed the organic contaminants in wastewater. Average residual BOD, COD, oil and grease values were 30, 92 and 8.3 mg l-1 respectively. Based on the laboratory results a final process design was developed.

  6. Reduction of COD in wastewater from an organized tannery industrial region by Electro-Fenton process

    International Nuclear Information System (INIS)

    Kurt, Ugur; Apaydin, Omer; Gonullu, M. Talha

    2007-01-01

    Advanced oxidation processes (AOPs) have led the way in the treatment of aqueous waste and are rapidly becoming the chosen technology for many applications. In this paper, COD reduction potential of leather tanning industry wastewaters by Electro-Fenton (EF) oxidation, as one of the AOPs, was experimentally evaluated. The wastewater sample was taken from an outlet of an equalization basin in a common treatment plant of an organized tannery industrial region in Istanbul, Turkey. Treatment of the wastewater was carried out by an electrochemical batch reactor equipped with two iron electrodes, which were connected parallel to each other. The oxidation process was studied for optimization of H 2 O 2 and the electricity consumptions were observed at different contact times under different pH conditions (3.0, 5.0 and 7.2). In each case, electricity consumption for decreased COD mass was estimated. In this process, COD was reduced by 60-70% within 10 min. By taking into consideration the local sewerage discharge limit, applicability of EF process for the tannery wastewaters was evaluated

  7. Use of constructed wetland for the removal of heavy metals from industrial wastewater.

    Science.gov (United States)

    Khan, Sardar; Ahmad, Irshad; Shah, M Tahir; Rehman, Shafiqur; Khaliq, Abdul

    2009-08-01

    This study was conducted to investigate the effectiveness of a continuous free surface flow wetland for removal of heavy metals from industrial wastewater, in Gadoon Amazai Industrial Estate (GAIE), Swabi, Pakistan. Industrial wastewater samples were collected from the in-let, out-let and all cells of the constructed wetland (CW) and analyzed for heavy metals such as lead (Pb), cadmium (Cd), iron (Fe), nickel (Ni), chromium (Cr) and copper (Cu) using standard methods. Similarly, samples of aquatic macrophytes and sediments were also analyzed for selected heavy metals. Results indicate that the removal efficiencies of the CW for Pb, Cd, Fe, Ni, Cr, and Cu were 50%, 91.9%, 74.1%, 40.9%, 89%, and 48.3%, respectively. Furthermore, the performance of the CW was efficient enough to remove the heavy metals, particularly Cd, Fe, and Cu, from the industrial wastewater fed to it. However, it is suggested that the metal removal efficiency of the CW can be further enhanced by using proper management of vegetation and area expansion of the present CW.

  8. Anaerobic sequencing batch reactor in pilot scale for treatment of tofu industry wastewater

    Science.gov (United States)

    Rahayu, Suparni Setyowati; Purwanto, Budiyono

    2015-12-01

    The small industry of tofu production process releases the waste water without being processed first, and the wastewater is directly discharged into water. In this study, Anaerobic Sequencing Batch Reactor in Pilot Scale for Treatment of Tofu Industry was developed through an anaerobic process to produce biogas as one kind of environmentally friendly renewable energy which can be developed into the countryside. The purpose of this study was to examine the fundamental characteristics of organic matter elimination of industrial wastewater with small tofu effective method and utilize anaerobic active sludge with Anaerobic Sequencing Bath Reactor (ASBR) to get rural biogas as an energy source. The first factor is the amount of the active sludge concentration which functions as the decomposers of organic matter and controlling selectivity allowance to degrade organic matter. The second factor is that HRT is the average period required substrate to react with the bacteria in the Anaerobic Sequencing Bath Reactor (ASBR).The results of processing the waste of tofu production industry using ASBR reactor with active sludge additions as starter generates cumulative volume of 5814.4 mL at HRT 5 days so that in this study it is obtained the conversion 0.16 L of CH4/g COD and produce biogas containing of CH4: 81.23% and CO2: 16.12%. The wastewater treatment of tofu production using ASBR reactor is able to produce renewable energy that has economic value as well as environmentally friendly by nature.

  9. Ecotoxicity of raw and treated effluents generated by a veterinary medicine industry

    Directory of Open Access Journals (Sweden)

    Bianca de Souza Maselli

    2013-08-01

    Full Text Available Effluents from veterinary pharmaceutical industries that formulate medicines are mainly generated during the washing of equipment. The aim of this work was to evaluate the acute toxicity to Daphnia similis and chronic toxicity to Ceriodaphnia dubia of raw and treated effluents generated by a veterinary pharmaceutical industry. The industrial effluent treatment system comprises a step of chemical treatment (coagulation-sedimentation forced followed by aerobic biological treatment (activated sludge process. Five samplings campaigns were performed from October 2011 to July 2012. The raw effluent samples showed high acute and chronic toxicity (acute: fourth sampling with EC50 - 48-h of <0.001% and chronic: third sampling with IC50 - 7-d of <0.0001%. The chemically treated effluent samples were the most toxic with EC50 - 48-h between <0.001 and 0.1% and IC50 - 7-d between 0.00001 and 0.0001%. This increase in toxicity is probably related to the use of aluminum sulfate as flocculating agent. The biological treatment led to a small reduction in toxicity of the effluents. The selected ecotoxicological tests were adequate for detecting the effluent toxicity and useful for evaluating the efficiency of the steps of the effluent treatment. Improvements in the industrial wastewater treatment system should be implemented in order to reduce the observed toxicity of the final effluent.

  10. Influence of wastewater characteristics on handling food-processing industry wastewaters

    DEFF Research Database (Denmark)

    Maya Altamira, Larisa

    fem sammensatte spildevandsprøver fra fire industrier viste at et vist indhold af acetat medførte hæmning af den hydrolytiske og methanogene aktivitet i spildevand fra grøntsags- og produktion af vegetabilske olier. Dette spildevand indeholdt bemærkelsesværdigt nok ikke nogen lipider, og når det blev...

  11. Effects of Hydraulic Retention Time on the Performance of a Membrane Bioreactor Treating Municipal Wastewater

    Directory of Open Access Journals (Sweden)

    Hadi Falahati

    2017-09-01

    Full Text Available There is an increasing demand for effluents of higher quality from wastewater treatment plants due to the more stringent quality standards as well as the increasing pressure on water resources worldwide, which calls for effluent recycle and reuse. Membrane bioreactors (MBRs have been recently gaining rapid popularity as a promising technology for wastewater treatment. In order to improve the quality of the effluent from Shiraz wastewater treatment plant, an on-site pilot-scale membrane bioreactor was operated for 9 months. The pilot plant built at Shiraz wastewater treatment plant consisted of an aerobic reactor and a membrane compartment containing one submerged hollow fiber membrane module. In this study, eleven different aerobic hydraulic retention times (HRT ranging from 2 to 12 hours were tested to determine the membrane capacity and to investigate the performance of the system in removing total ammonia nitrogen, organic matter, total suspended solids, and turbidity.The system recorded a perfectly stable removal efficiency over the whole experimental period, except for the 2-hour aerobic HRT, so that its COD and BOD reductions exceeded 95% and 99%, respectively. Moreover, the system achieved complete nitrification in a stable manner during the whole study period, except for the 2-hour aerobic operation period. TSS concentration was almost zero and turbidity was less than 1 NTU. Membrane capacity measurements showed an average flux of 5.5 Lm-2h-1 with a mean trans-membrane pressure difference of 30 kPa. Results showed that the MBR outperformed the conventional sewage treatment processes. Additionally, it was not affected by aerobic HRT changes (12, 10, 8, 6, 4, and 3h. Based on the effluent qulity, teh system may be recommended for application toward water reuse in industrial and agricultural settings

  12. Fate of heavy metals in vertical subsurface flow constructed wetlands treating secondary treated petroleum refinery wastewater in Kaduna, Nigeria.

    Science.gov (United States)

    Mustapha, Hassana Ibrahim; van Bruggen, J J A; Lens, P N L

    2018-01-02

    This study examined the performance of pilot-scale vertical subsurface flow constructed wetlands (VSF-CWs) planted with three indigenous plants, i.e. Typha latifolia, Cyperus alternifolius, and Cynodon dactylon, in removing heavy metals from secondary treated refinery wastewater under tropical conditions. The T. latifolia-planted VSF-CW had the best heavy metal removal performance, followed by the Cyperus alternifolius-planted VSF-CW and then the Cynodon dactylon-planted VSF-CW. The data indicated that Cu, Cr, Zn, Pb, Cd, and Fe were accumulated in the plants at all the three VSF-CWs. However, the accumulation of the heavy metals in the plants accounted for only a rather small fraction (0.09-16%) of the overall heavy metal removal by the wetlands. The plant roots accumulated the highest amount of heavy metals, followed by the leaves, and then the stem. Cr and Fe were mainly retained in the roots of T. latifolia, Cyperus alternifolius, and Cynodon dactylon (TF < 1), meaning that Cr and Fe were only partially transported to the leaves of these plants. This study showed that VSF-CWs planted with T. latifolia, Cyperus Alternifolius, and Cynodon dactylon can be used for the large-scale removal of heavy metals from secondary refinery wastewater.

  13. Photodegradation kinetics and transformation products of ketoprofen, diclofenac and atenolol in pure water and treated wastewater

    International Nuclear Information System (INIS)

    Salgado, R.; Pereira, V.J.; Carvalho, G.; Soeiro, R.; Gaffney, V.; Almeida, C.; Cardoso, V. Vale; Ferreira, E.; Benoliel, M.J.

    2013-01-01

    Highlights: ► Direct UV photolysis of 3 pharmaceuticals in pure and waste water was investigated. ► Ketoprofen has higher photodegradion kinetics, followed by diclofenac and atenolol. ► MP/UV photodegradation products were identified for the 3 compounds. ► Photodegradation pathways were proposed to explain the obtained products. ► The persistent photoproducts were identified for each compound. -- Abstract: Pharmaceutical compounds such as ketoprofen, diclofenac and atenolol are frequently detected at relatively high concentrations in secondary effluents from wastewater treatment plants. Therefore, it is important to assess their transformation kinetics and intermediates in subsequent disinfection processes, such as direct ultraviolet (UV) irradiation. The photodegradation kinetics of these compounds using a medium pressure (MP) lamp was assessed in pure water, as well as in filtered and unfiltered treated wastewater. Ketoprofen had the highest time- and fluence-based rate constants in all experiments, whereas atenolol had the lowest values, which is consistent with the corresponding decadic molar absorption coefficient and quantum yield. The fluence-based rate constants of all compounds were evaluated in filtered and unfiltered wastewater matrices as well as in pure water. Furthermore, transformation products of ketoprofen, diclofenac and atenolol were identified and monitored throughout the irradiation experiments, and photodegradation pathways were proposed for each compound. This enabled the identification of persistent transformation products, which are potentially discharged from WWTP disinfection works employing UV photolysis

  14. Photodegradation kinetics and transformation products of ketoprofen, diclofenac and atenolol in pure water and treated wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, R. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); ESTS-IPS, Escola Superior de Tecnologia de Setúbal do Instituto Politécnico de Setúbal, Rua Vale de Chaves, Campus do IPS, Estefanilha, 2910-761 Setúbal (Portugal); Pereira, V.J. [Instituto de Biologia Experimental e Tecnológica (IBET), Av. da República (EAN), 2784-505 Oeiras (Portugal); Instituto de Tecnologia Química e Biológica (ITQB) – Universidade Nova de Lisboa (UNL), Av. da República, Estação Agronómica Nacional, 2780-157 Oeiras, 5 Portugal (Portugal); Carvalho, G., E-mail: gs.carvalho@fct.unl.pt [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Instituto de Biologia Experimental e Tecnológica (IBET), Av. da República (EAN), 2784-505 Oeiras (Portugal); Soeiro, R. [REQUIMTE/CQFB, Chemistry Department, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Gaffney, V.; Almeida, C. [Institute for Medicines and Pharmaceutical Sciences (iMed.UL), Faculdade de Farmácia da Universidade de Lisboa (FFUL), Av. Prof. Gama Pinto, 1600-049 Lisboa (Portugal); Cardoso, V. Vale; Ferreira, E.; Benoliel, M.J. [Empresa Portuguesa das Águas Livres, S.A., Direcção de Controlo de Qualidade da Água, Laboratório Central, Avenida de Berlim, 15, 1800-031 Lisboa (Portugal); and others

    2013-01-15

    Highlights: ► Direct UV photolysis of 3 pharmaceuticals in pure and waste water was investigated. ► Ketoprofen has higher photodegradion kinetics, followed by diclofenac and atenolol. ► MP/UV photodegradation products were identified for the 3 compounds. ► Photodegradation pathways were proposed to explain the obtained products. ► The persistent photoproducts were identified for each compound. -- Abstract: Pharmaceutical compounds such as ketoprofen, diclofenac and atenolol are frequently detected at relatively high concentrations in secondary effluents from wastewater treatment plants. Therefore, it is important to assess their transformation kinetics and intermediates in subsequent disinfection processes, such as direct ultraviolet (UV) irradiation. The photodegradation kinetics of these compounds using a medium pressure (MP) lamp was assessed in pure water, as well as in filtered and unfiltered treated wastewater. Ketoprofen had the highest time- and fluence-based rate constants in all experiments, whereas atenolol had the lowest values, which is consistent with the corresponding decadic molar absorption coefficient and quantum yield. The fluence-based rate constants of all compounds were evaluated in filtered and unfiltered wastewater matrices as well as in pure water. Furthermore, transformation products of ketoprofen, diclofenac and atenolol were identified and monitored throughout the irradiation experiments, and photodegradation pathways were proposed for each compound. This enabled the identification of persistent transformation products, which are potentially discharged from WWTP disinfection works employing UV photolysis.

  15. Combined Fenton oxidation and aerobic biological processes for treating a surfactant wastewater containing abundant sulfate

    International Nuclear Information System (INIS)

    Wang Xiaojun; Song Yang; Mai Junsheng

    2008-01-01

    The present study is to investigate the treatment of a surfactant wastewater containing abundant sulfate by Fenton oxidation and aerobic biological processes. The operating conditions have been optimized. Working at an initial pH value of 8, a Fe 2+ dosage of 600 mg L -1 and a H 2 O 2 dosage of 120 mg L -1 , the chemical oxidation demand (COD) and linear alkylbenzene sulfonate (LAS) were decreased from 1500 and 490 mg L -1 to 230 and 23 mg L -1 after 40 min of Fenton oxidation, respectively. Advanced oxidation pretreatment using Fenton reagent was very effective at enhancing the biodegradability of this kind of wastewater. The wastewater was further treated by a bio-chemical treatment process based on an immobilized biomass reactor with a hydraulic detention time (HRT) of 20 h after Fenton oxidation pretreatment under the optimal operating conditions. It was found that the COD and LAS of the final effluent were less than 100 and 5 mg L -1 , corresponding to a removal efficiencies of over 94% and 99%, respectively

  16. Evaluating two infiltration gallery designs for managed aquifer recharge using secondary treated wastewater.

    Science.gov (United States)

    Bekele, Elise; Toze, Simon; Patterson, Bradley; Fegg, Wolfgang; Shackleton, Mark; Higginson, Simon

    2013-03-15

    As managed aquifer recharge (MAR) becomes increasingly considered for augmenting water-sensitive urban areas, fundamental knowledge of the achievable scale, longevity and maintenance requirements of different options will become paramount. This paper reports on a 39 month pilot scale MAR scheme that infiltrated secondary treated wastewater through unsaturated sand into a limestone and sand aquifer. Two types of infiltration gallery were constructed to compare their hydraulic performance, one using crushed, graded gravel, the other using an engineered leach drain system (Atlantis Leach System(®)). Both galleries received 25 kL of nutrient-rich, secondary treated wastewater per day. The Atlantis gallery successfully infiltrated 17 ML of treated wastewater over three years. The slotted distribution pipe in the gravel gallery became clogged with plant roots after operating for one year. The infiltration capacity of the gravel gallery could not be restored despite high pressure cleaning, thus it was replaced with an Atlantis system. Reduction in the infiltration capacity of the Atlantis system was only observed when inflow was increased by about 3 fold for two months. The performance of the Atlantis system suggests it is superior to the gravel gallery, requiring less maintenance within at least the time frame of this study. The results from a bromide tracer test revealed a minimum transport time of 3.7 days for the recharged water to reach the water table below 9 m of sand and limestone. This set a limit on the time available for attenuation by natural treatment within the unsaturated zone before it recharged groundwater. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  17. Input-dependent life-cycle inventory model of industrial wastewater-treatment processes in the chemical sector.

    Science.gov (United States)

    Köhler, Annette; Hellweg, Stefanie; Recan, Ercan; Hungerbühler, Konrad

    2007-08-01

    Industrial wastewater-treatment systems need to ensure a high level of protection for the environment as a whole. Life-cycle assessment (LCA) comprehensively evaluates the environmental impacts of complex treatment systems, taking into account impacts from auxiliaries and energy consumption as well as emissions. However, the application of LCA is limited by a scarcity of wastewater-specific life-cycle inventory (LCI) data. This study presents a modular gate-to-gate inventory model for industrial wastewater purification in the chemical and related sectors. It enables the calculation of inventory parameters as a function of the wastewater composition and the technologies applied. Forthis purpose, data on energy and auxiliaries' consumption, wastewater composition, and process parameters was collected from chemical industry. On this basis, causal relationships between wastewater input, emissions, and technical inputs were identified. These causal relationships were translated into a generic inventory model. Generic and site-specific data ranges for LCI parameters are provided for the following processes: mechanical-biological treatment, high-pressure wet-air oxidation, nanofiltration, and extraction. The input- and technology-dependent process inventories help to bridge data gaps where primary data are not available. Thus, they substantially help to perform an environmental assessment of industrial wastewater purification in the chemical and associated industries, which may be used, for instance, for technology choices.

  18. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation

    International Nuclear Information System (INIS)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-01-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (±0.2) and a total COD of 12,100 (±910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32 ± 2 deg. C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m 3 day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe 2+ and H 2 O 2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H 2 O 2 and Fe 2+ dosages, and the ratio of H 2 O 2 /Fe 2+ . Preliminary tests conducted with the dosages of 100 mg Fe 2+ /L and 200 mg H 2 O 2 /L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe 2+ and H 2 O 2 were investigated. Under the condition of 400 mg Fe 2+ /L and 200 mg H 2 O 2 /L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe 2+ /L and 1200 mg H 2 O 2 /L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit

  19. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation.

    Science.gov (United States)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-03-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (+/-0.2) and a total COD of 12,100 (+/-910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32+/-2 degrees C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m3day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe2+ and H2O2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H2O2 and Fe2+ dosages, and the ratio of H2O2/Fe2+. Preliminary tests conducted with the dosages of 100 mg Fe2+/L and 200 mg H2O2/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe2+ and H2O2 were investigated. Under the condition of 400 mg Fe2+/L and 200 mg H2O2/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe2+/L and 1200 mg H2O2/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit.

  20. Estimation of optimum operating parameters of UASB reactor treating flax retting wastewater by kinetic model

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J.; Ukita, M.; Nakanishi, H.; Imai, T. [Yamaguchi University, Yamaguchi (Japan); Fukagawa, M. [Ube Technical College, Yamaguchi (Japan)

    1995-08-21

    A laboratory study was used to develop a simplified kinetic model, to evaluate the kinetic parameters, and to provide rational design parameters for a pilot plant treating flax retting wastewater by means of the simulation of optimal operation of the UASB reactor. The results indicated that the developed model can be used predicatively for assessing plant performance and when the concentration of the influent is at the range of 5.5-7.3gCOD/l, the concentration of the hard-biodegradable materials is 0.46 gCOD/l. 14 refs., 9 figs., 3 tabs.

  1. Effects of domestic wastewater treated by anaerobic stabilization on soil pollution, plant nutrition, and cotton crop yield.

    Science.gov (United States)

    Uzen, Nese; Cetin, Oner; Unlu, Mustafa

    2016-12-01

    This study has aimed to determine the effects of treated wastewater on cotton yield and soil pollution in Southeastern Anatolia Region of Turkey during 2011 and 2012. The treated wastewater was provided from the reservoir operated as anaerobic stabilization. After treatment, suspended solids (28-60 mg/l), biological oxygen demand (29-30 mg/l), and chemical oxygen demand (71-112 mg/l) decreased significantly compared to those in the wastewater. There was no heavy metal pollution in the water used. There were no significant amounts of coliform bacteria, fecal coliform, and Escherichia coli compared to untreated wastewater. The cottonseed yield (31.8 g/plant) in the tanks where no commercial fertilizers were applied was considerably higher compared to the yield (17.2 g/plant) in the fertilized tanks where a common nitrogenous fertilizer was utilized. There were no significant differences between the values of soil pH. Soil electrical conductivity (EC) after the experiment increased from 0.8-1.0 to 0.9-1.8 dS/m. Heavy metal pollution did not occur in the soil and plants, because there were no heavy metals in the treated wastewater. It can be concluded that treated domestic wastewater could be used to grow in a controlled manner crops, such as cotton, that would not be used directly as human nutrients.

  2. APPLICATION OF ELECTROCHEMICAL METHODS FOR DECREASING OF CHEMICAL OXYGEN DEMAND (COD AND TOTAL SUSPENDED SOLID (TSS OF TOFU INDUSTRIAL WASTEWATER

    Directory of Open Access Journals (Sweden)

    Suyata

    2015-05-01

    Full Text Available Tofu industrial wastewater has high COD and TSS level, which it cause an environmental pollution. Therefore, it is necessary to decrease the value of COD and TSS of tofu industrial wastewater before discharge into the water body. Decreasing of COD and TSS values can be carried out using an electrochemical method. The purpose of this research was to determine the effect of potential, electrode distance, pH, and time to decrease of COD and TSS value of the tofu industrial wastewater. The experiment has been performed by electrolysis tofu industrial wastewater using PbO2 as anode and Pb as cathode. The result of the research showed that under the optimum conditions of 12 V voltage, 1 cm electrode distance, pH 1, and electrolysis time of 120 minutes, decreasing COD and TSS of 96.33% and 87.87% respectively

  3. Spatial Assessment of Cancer Incidences and the Risks of Industrial Wastewater Emission in China

    Directory of Open Access Journals (Sweden)

    Yingru Li

    2016-05-01

    Full Text Available China’s rapid economic growth and social transitions have deteriorated environmental conditions and caused further public health issues in last three decades. This study examines the complex mechanisms of how socioeconomic transitions and physical environmental conditions impact public health, especially with respect to increasing cancer incidences in mainland China from a spatial-temporal perspective. Specifically, (1 spatial variations of seven types of cancer incidences were analyzed in relation to heavy metal emissions from industrial wastewater at the prefecture-level city scale from 2004 to 2009. Additionally; (2 spatial statistical methods were employed to explore the associations between health outcome, heavy metal emissions from industrial wastewater (arsenic, chromium, cadmium, mercury, lead, as well as socioeconomic transitions (industrialization, urbanization, globalization and physical environmental factors (hydrology and vegetation coverage. Results showed a significant increase of cancer incidences between 2004 and 2009. Consistent with the spatial pattern of heavy metal emissions, cancer patient clusters were identified in both traditional industrial bases and newly industrialized economic zones, especially in major cities located at downstream watersheds, including Beijing, Shanghai, Guangzhou, Shenyang, and Wuhan. The results also revealed the double-edged effects of industrialization, economic growth, and urbanization on natural environment and human health. The findings provide informative knowledge of heavy metal pollution and cancer outbreaks in China and therefore offer valuable reference for authorities formulating regulations.

  4. Mathematical modeling of simultaneous carbon-nitrogen-sulfur removal from industrial wastewater.

    Science.gov (United States)

    Xu, Xi-Jun; Chen, Chuan; Wang, Ai-Jie; Ni, Bing-Jie; Guo, Wan-Qian; Yuan, Ye; Huang, Cong; Zhou, Xu; Wu, Dong-Hai; Lee, Duu-Jong; Ren, Nan-Qi

    2017-01-05

    A mathematical model of carbon, nitrogen and sulfur removal (C-N-S) from industrial wastewater was constructed considering the interactions of sulfate-reducing bacteria (SRB), sulfide-oxidizing bacteria (SOB), nitrate-reducing bacteria (NRB), facultative bacteria (FB), and methane producing archaea (MPA). For the kinetic network, the bioconversion of C-N by heterotrophic denitrifiers (NO 3 - →NO 2 - →N 2 ), and that of C-S by SRB (SO 4 2- →S 2- ) and SOB (S 2- →S 0 ) was proposed and calibrated based on batch experimental data. The model closely predicted the profiles of nitrate, nitrite, sulfate, sulfide, lactate, acetate, methane and oxygen under both anaerobic and micro-aerobic conditions. The best-fit kinetic parameters had small 95% confidence regions with mean values approximately at the center. The model was further validated using independent data sets generated under different operating conditions. This work was the first successful mathematical modeling of simultaneous C-N-S removal from industrial wastewater and more importantly, the proposed model was proven feasible to simulate other relevant processes, such as sulfate-reducing, sulfide-oxidizing process (SR-SO) and denitrifying sulfide removal (DSR) process. The model developed is expected to enhance our ability to predict the treatment of carbon-nitrogen-sulfur contaminated industrial wastewater. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A Comprehensive Study on the Application of Reverse Osmosis (RO) Technology for the Petroleum Industry Wastewater Treatment

    OpenAIRE

    Shahryar Jafarinejad

    2017-01-01

    Large quantities of oily wastewaters can be generated from the activities and processes in the petroleum industry which draining of these effluents not only pollutes the environment but also reduces the yield of oil and water. Therefore, development of treatment processes for petroleum industry wastewaters is vital in order to prevent serious environmental damage and provide a source of water for beneficial use. Reverse osmosis (RO) can be the most common membrane process used for desalinatio...

  6. Fenton's peroxidation and coagulation processes for the treatment of combined industrial and domestic wastewater.

    Science.gov (United States)

    Badawy, M I; Ali, M E M

    2006-08-25

    As a consequence of the population growth, major efforts have been made by the Egyptian government to construct new industrial areas. Tenth of Ramadan City is one of the most important industrial cities in Egypt. The wastewater generated from various industrial activities was highly contaminated with organic matters as indicated by COD (1750-3323 mg/L), TSS (900-3000 mg/L) and oil and grease (13.2-95.5 mg/L). All overall appraisals of the analytical data from the industrial wastewater indicate that pretreatment is required for all industrial sectors to achieve compliance with the Egyptian Environmental law which requires effective pretreatment of industrial wastewater prior to its discharge into public sewers. Treatability studies via conventional and Fenton processes have been investigated. The efficiency of conventional treatment methods led to 63% COD and 44% color removal by using FeCl(3) as coagulant. Various coagulant aids and powdered activated carbon (PAC) were added to 400mg/L FeCl(3) in order to enhance the removal of color. It was found that polyacrylamide polymer, bentonite and PAC increased the efficiency of the treatments where the color removal increased to 79%, by cationic polymer, 73% by anionic polymer, 84.5% by bentonite and 95% for 0.4 g/L PAC. Fenton process was investigated which under the operating conditions (pH 3.0+/-0.2, Fe(2+) dose=400 mg/L and H(2)O(2)=550 mg/L), color removal up to 100% and more than 90% of COD removal were achieved.

  7. Chemical oxidation of carwash industry wastewater as an effort to decrease water pollution

    Science.gov (United States)

    Bhatti, Zulfiqar Ahmad; Mahmood, Qaisar; Raja, Iftikhar Ahmad; Malik, Amir Haider; Khan, Muhammad Suleman; Wu, Donglei

    Car wash wastewater (CWW) contains petroleum, hydrofluoric acid, ammonium bifluoride products, paint residues, rubber, phosphates, oil, grease and volatile organic compounds (VOCs). The present study dealt with various investigations conducted for the treatment of CWW. A treatment system of 5 L capacity was designed in the laboratory. Due to high load of oil and grease, CWW was aerated and scum was removed. Alum was used as coagulant in primary treatment which resulted 93% and 97% reduction in COD and turbidity. During secondary treatment CWW was further treated with waste hydrogen peroxide which resulted in further 71% and 83% reduction in COD and turbidity, respectively. Other desirable changes were also observed in pH, total dissolved solids (TDS), conductivity and dissolved oxygen contents. It was concluded that designed system could be effectively used to treat carwash wastewater that could be reused in the same station.

  8. Laboratory and Feasibility Study for Industrial Wastewater Effluents Treatment by Radiation

    International Nuclear Information System (INIS)

    Zimek, Z.; Głuszewski, W.

    2012-01-01

    The study of wastewater treatment by radiation regarding chemical processes contribution and physical-chemical separation of highly concentrated non-organic pollutants deposited in specific industrial waste are proposed. Laboratory stand should be build and the study should be performed to confirm possible mechanism of the sedimentation process of nonorganic pollutants during separation initiated by ionizing radiation. Evaluation from technical and economical point of view of this specific radiation technology and feasibility study preparation for industrial facility will be the main output at the final stage of the project. (author)

  9. Promoting the Growth of Chlorella vulgaris in Secondary Wastewater Treatment Effluent of Tofu Industry using Azospirillum sp

    OpenAIRE

    Wahyunanto Agung Nugroho; Musthofa Lutfi; Bambang Susilo

    2016-01-01

    The objective of this research is to investigate the influence of growth promoting bacteria (GPB) Azospirillum sp on the growth of microalgae Chlorella vulgaris in wastewater of tofu industry as a medium. To observe the influence, about 106 cells/mL of Chlorella vulgaris was cultivated in 1 L of wastewater of tofu industry. The wastewater was an effluent of an aerobic treatment. Six different treatments were set regarding to the Azospirillum sp added to the medium. The glass was marked as A0 ...

  10. Comparison of aerated marsh-pond-marsh and continuous marsh constructed wetlands for treating swine wastewater.

    Science.gov (United States)

    Forbes, Dean A; Reddy, G B; Hunt, Patrick G; Poach, M E; Ro, Kyoung S; Cyrus, Johnsely S

    2010-01-01

    Increased swine production in North Carolina has resulted in greater waste generation and is demanding some emerging new innovative technologies to effectively treat swine wastewater. One of the cost-effective and passive methods to treat swine wastewater is using constructed wetlands. The objective of this study was to evaluate the N removal under two N loads in 3 different wetland systems: aerated marsh-pond-marsh (M-P-M), aerated marsh-covered pond-marsh (M-FB-M), and continuous marsh (CM) with two days drain and five days flood cycle. Swine wastewater from an anaerobic lagoon was applied to the constructed wetland cells (11 m wide x 40 m length) at two N loading rates of 7 and 12 kg N ha(-1) day(-1)from June to July and August to September 2005, respectively. Weekly inflow and outflow samples were collected for N, P, TS, and COD analysis. Total N reductions (%) at low and high N loading rates were 85.8 and 51.8; 86.3 and 63.3; and 86.2 and 61.8 for M-P-M, M-FB-M, and CM, respectively. Aeration had no significant (P > 0.05) impact on N removal. However, significant (P 0.05) in N reduction was found among wetland systems. Vegetation uptake of N was negligible, ranging from 1.2 to 1.8 %. No significant (P > 0.05) differences in TS and COD removal were observed between the wetland systems.

  11. Evaluation of performance in a combined UASB and aerobic contact oxidation process treating acrylic wastewater.

    Science.gov (United States)

    Li, Anfeng; Dong, Na; He, Manni; Pan, Tao

    2015-01-01

    The lab-scale and full-scale performance of a combined mesophilic up-flow anaerobic sludge blanket (UASB) and aerobic contact oxidation (ACO) process for treating acrylic wastewater was studied. During lab-scale experiment, the overwhelmed volumetric load for UASB was above 6 kg chemical oxygen demand (COD) ·(m(-3)·d(-1)) since COD removal efficiency dropped dramatically from 73% at 6 kg COD·(m(-3)·d(-1)) to 61% at 7 kg COD·(m(-3)·d(-1)) and 53% at 8 kg COD·(m(-3)·d(-1)). Further results showed that an up-flow fluid velocity of 0.5 m h(-1) for UASB obtained a highest COD removal efficiency of 75%, and the optimum COD volumetric load for the corresponding ACO was 1.00 kg COD·(m(-3)·d(-1)). Based on the configuration of the lab-scale experiment, a full-scale application with an acrylic wastewater treatment capacity of 8 m3 h(-1) was constructed and operated at a volumetric load of 5.5 kg COD·(m(-3)·d(-1)), an up-flow fluid velocity of 0.5 m h(-1) for UASB and a volumetric load of 0.9 kg COD·(m(-3)·d(-1)) for ACO; and the final effluent COD was around 740 mg L(-1). The results suggest that a combined UASB-ACO process is promising for treating acrylic wastewater.

  12. Modeling of membrane bioreactor treating hypersaline oily wastewater by artificial neural network

    International Nuclear Information System (INIS)

    Pendashteh, Ali Reza; Fakhru'l-Razi, A.; Chaibakhsh, Naz; Abdullah, Luqman Chuah; Madaeni, Sayed Siavash; Abidin, Zurina Zainal

    2011-01-01

    Highlights: → Hypersaline oily wastewater was treated in a membrane bioreactor. → The effects of salinity and organic loading rate were evaluated. → The system was modeled by neural network and optimized by genetic algorithm. → The model prediction agrees well with experimental values. → The model can be used to obtain effluent characteristics less than discharge limits. - Abstract: A membrane sequencing batch reactor (MSBR) treating hypersaline oily wastewater was modeled by artificial neural network (ANN). The MSBR operated at different total dissolved solids (TDSs) (35,000; 50,000; 100,000; 150,000; 200,000; 250,000 mg/L), various organic loading rates (OLRs) (0.281, 0.563, 1.124, 2.248, and 3.372 kg COD/(m 3 day)) and cyclic time (12, 24, and 48 h). A feed-forward neural network trained by batch back propagation algorithm was employed to model the MSBR. A set of 193 operational data from the wastewater treatment with the MSBR was used to train the network. The training, validating and testing procedures for the effluent COD, total organic carbon (TOC) and oil and grease (O and G) concentrations were successful and a good correlation was observed between the measured and predicted values. The results showed that at OLR of 2.44 kg COD/(m 3 day), TDS of 78,000 mg/L and reaction time (RT) of 40 h, the average removal rate of COD was 98%. In these conditions, the average effluent COD concentration was less than 100 mg/L and met the discharge limits.

  13. Optimizing electrocoagulation and electro-Fenton process for treating car wash wastewater

    Directory of Open Access Journals (Sweden)

    Seyyedali Mirshahghassemi

    2017-02-01

    Full Text Available Background: Car wash wastewater contains several contaminants such as organic matter, oil, grease, detergents and phosphates, all of which are harmful for the environment. In this study, the application of electrocoagulation (EC to treat car wash wastewater has been studied, and the operating parameters optimized. The electro-Fenton (EF for further contaminant removal was also investigated. Methods: In EC process, the effect of pH, current density, and the reaction time of the removal efficiency of chemical oxygen demand (COD, phosphate, and turbidity were investigated using the response surface methodology (RSM. The electrochemical cell consisted of four iron electrodes that were connected to a power supply using a monopolar arrangement. In the EF process, the effect of pH, reaction time, and hydrogen peroxide concentration on COD removal efficiency were probed. Results: The optimum pH, current density, and the reaction time for the EC process were 7.3, 4.2 mA cm-2 and 20.3 minutes, respectively. Under these conditions, the COD, phosphate, and turbidity removal percentages were 80.8%, 94.9% and 85.5%, respectively, and the specific energy consumption was 1.5 kWh m-3. For the EF process, the optimum pH, reaction time, current and hydrogen peroxide dosage were 3, 10 minutes, 2 A and 500 mg L-1, respectively. The EF showed higher COD removal efficiency (85.6% with a lower specific energy consumption (0.5 kWh m-3 and reaction time compared to the EC. Conclusion: This study shows that both EC and EF can effectively treat car wash wastewater with high removal efficiency within a short reaction time.

  14. The potential of biodiesel production from Botryococcus sp. biomass after phycoremediation of domestic and industrial wastewater

    Science.gov (United States)

    Gani, P.; Sunar, N. M.; Matias-Peralta, H. M.; Latiff, A. A. A.; Parjo, U. K.; Embong, Z.; Khalid, A.; Tajudin, S. A. A.

    2016-11-01

    The aim of the present work is to investigate the capability of microalgae, known as Botryococcus sp. for wastewater phycoremediation and potential biodiesel production. The vertical closed photobioreactors (PBR) were employed and supplemented with domestic wastewater (DW) and food industry wastewater (FW) at different batch of study. The cultivation was conducted under natural outdoor condition for 12 days. The results revealed that the removal of pollutant and nutrients presence in both wastewaters with constantly decrease proportionate to the increase in cultivation time. The chemical oxygen demand (COD), total phosphorus (TP) and total organic carbon (TOC) were successfully removed up to 84.9%, 69.3% and 93.3%, respectively in DW while 96.1%, 35.5% and 87.2%, respectively in FW. The result on FT-IR analysis of microalgae oil was shown comparable with conventional palm oil based biodiesel in term of IR spectra. This study suggests that Botryococcus sp. has tremendous potential in pollutants removal and biodiesel production for renewable energy development.

  15. Nitrogen removal and microbial community shift in an aerobic denitrification reactor bioaugmented with a Pseudomonas strain for coal-based ethylene glycol industry wastewater treatment.

    Science.gov (United States)

    Du, Cong; Cui, Chong-Wei; Qiu, Shan; Shi, Sheng-Nan; Li, Ang; Ma, Fang

    2017-04-01

    An aerobic denitrification system, initially bioaugmented with Pseudomonas strain T13, was established to treat coal-based ethylene glycol industry wastewater, which contained 3219 ± 86 mg/L total nitrogen (TN) and 1978 ± 14 mg/L NO 3 - -N. In the current study, a stable denitrification efficiency of 53.7 ± 4.7% and nitrite removal efficiency of 40.1 ± 2.7% were achieved at different diluted influent concentrations. Toxicity evaluation showed that a lower toxicity of effluent was achieved when industry wastewater was treated by stuffing biofilm communities compared to suspended communities. Relatively high TN removal (~50%) and chemical oxygen demand removal percentages (>65%) were obtained when the influent concentration was controlled at below 50% of the raw industry wastewater. However, a further increased concentration led to a 20-30% decrease in nitrate and nitrite removal. Microbial network evaluation showed that a reduction in Pseudomonas abundance was induced during the succession of the microbial community. The napA gene analysis indicated that the decrease in nitrate and nitrite removal happened when abundance of Pseudomonas was reduced to less than 10% of the overall stuffing biofilm communities. Meanwhile, other denitrifying bacteria, such as Paracoccus, Brevundimonas, and Brucella, were subsequently enriched through symbiosis in the whole microbial network.

  16. Survival, reproduction, growth, and parasite resistance of aquatic organisms exposed on-site to wastewater treated by advanced treatment processes.

    Science.gov (United States)

    Schlüter-Vorberg, Lisa; Knopp, Gregor; Cornel, Peter; Ternes, Thomas; Coors, Anja

    2017-05-01

    Advanced wastewater treatment technologies are generally known to be an effective tool for reducing micropollutant discharge into the aquatic environment. Nevertheless, some processes such as ozonation result in stable transformation products with often unknown toxicity. In the present study, whole effluents originating from nine different steps of advanced treatment combinations were compared for their aquatic toxicity. Assessed endpoints were survival, growth and reproduction of Lumbriculus variegatus, Daphnia magna and Lemna minor chronically exposed in on-site flow-through tests based on standard guidelines. The treatment combinations were activated sludge treatment followed by ozonation with subsequent filtration by granular activated carbon or biofilters and membrane bioreactor treatment of raw wastewater followed by ozonation. Additionally, the impact of treated wastewater on the immune response of invertebrates was investigated by challenging D. magna with a bacterial endoparasite. Conventionally treated wastewater reduced reproduction of L. variegatus by up to 46%, but did not affect D. magna and L. minor with regard to survival, growth, reproduction and parasite resistance. Instead, parasite susceptibility was significantly reduced in D. magna exposed to conventionally treated as well as ozonated wastewater in comparison to D. magna exposed to the medium control. None of the three test organisms provided clear evidence that wastewater ozonation leads to increased aquatic toxicity. Rather than to the presence of toxic transformation products, the affected performance of L. variegatus could be linked to elevated concentrations of ammonium and nitrite that likely resulted from treatment failures. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Potential of Indigenous Bacteria for Removing Cadmium from Industrial Wastewater in Lawang, East Java

    Directory of Open Access Journals (Sweden)

    Agung Pambudiono

    2018-01-01

    Full Text Available Heavy metals have been used in various areas around the world especially in the industrial sector. Heavy metals contamination is very dangerous for ecosystem because of its toxicity for some organisms. Cadmium (Cd is a dangerous metal pollutant that can cause remarkable diverse of toxic effects, in particular for humans and animals. The use of bacteria as bioremediation agents has been widely studied because more efficient, less cost, and environmentally friendly strategy. This present study aimed to isolate and identify Cd-resistant bacteria from the industrial disposal site. Wastewater samples were collected from disposal site of agar flour industry in Lawang Malang, East Java. The collected wastewater effluent was analyzed for physicochemical properties. Isolation of Cd-resistant bacteria was carried out using serial dilution. Bacterial isolates were observed and tested for their effects on the content of Cd. The content of Cd was tested daily using Atomic Absorption Spectroscopy (AAS for seven consecutive days. Data was analyzed using one-way ANOVA (p < 0.05 and Tukey test. Characterization of potential bacterium was performed using bacterial identification kit. Four bacteria isolates have been successfully isolated from the wastewater sample. There was a statistically significant difference between groups as determined by one-way ANOVA (F = 1229.62, p = 0.00. A Tukey post hoc test revealed that all conditions are significantly different from each other. The content of Cd in wastewater sample was statistically significantly lower after taking the A isolate (3.39 mg/L, p = 0.00, B Isolate (1.47 mg/L, p = 0.00, C Isolate (1.15 mg/L, p = 0.00, and D isolate (1.95 mg/L, p = 0.00 compared to the control treatment (5.11 mg/L, p = 0.00. Two of the most potential isolates identified as Pseudomonas flourescens (C isolate and Enterobacter agglomerans (B isolate.

  18. 2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2012 through October 31, 2013. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of special compliance conditions • Discussion of the facility’s environmental impacts During the 2013 reporting year, an estimated 9.64 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.

  19. Inhibition of nitrification in municipal wastewater-treating photobioreactors: Effect on algal growth and nutrient uptake.

    Science.gov (United States)

    Krustok, I; Odlare, M; Truu, J; Nehrenheim, E

    2016-02-01

    The effect of inhibiting nitrification on algal growth and nutrient uptake was studied in photobioreactors treating municipal wastewater. As previous studies have indicated that algae prefer certain nitrogen species to others, and because nitrifying bacteria are inhibited by microalgae, it is important to shed more light on these interactions. In this study allylthiourea (ATU) was used to inhibit nitrification in wastewater-treating photobioreactors. The nitrification-inhibited reactors were compared to control reactors with no ATU added. Microalgae had higher growth in the inhibited reactors, resulting in a higher chlorophyll a concentration. The species mix also differed, with Chlorella and Scenedesmus being the dominant genera in the control reactors and Cryptomonas and Chlorella dominating in the inhibited reactors. The nitrogen speciation in the reactors after 8 days incubation was also different in the two setups, with N existing mostly as NH4-N in the inhibited reactors and as NO3-N in the control reactors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Electricity and biomass production in a bacteria-Chlorella based microbial fuel cell treating wastewater

    Science.gov (United States)

    Commault, Audrey S.; Laczka, Olivier; Siboni, Nachshon; Tamburic, Bojan; Crosswell, Joseph R.; Seymour, Justin R.; Ralph, Peter J.

    2017-07-01

    The chlorophyte microalga Chlorella vulgaris has been exploited within bioindustrial settings to treat wastewater and produce oxygen at the cathode of microbial fuel cells (MFCs), thereby accumulating algal biomass and producing electricity. We aimed to couple these capacities by growing C. vulgaris at the cathode of MFCs in wastewater previously treated by anodic bacteria. The bioelectrochemical performance of the MFCs was investigated with different catholytes including phosphate buffer and anode effluent, either in the presence or absence of C. vulgaris. The power output fluctuated diurnally in the presence of the alga. The maximum power when C. vulgaris was present reached 34.2 ± 10.0 mW m-2, double that observed without the alga (15.6 ± 9.7 mW m-2), with a relaxation of 0.19 gL-1 d-1 chemical oxygen demand and 5 mg L-1 d-1 ammonium also removed. The microbial community associated with the algal biofilm included nitrogen-fixing (Rhizobiaceae), denitrifying (Pseudomonas stutzeri and Thauera sp., from Pseudomonadales and Rhodocyclales orders, respectively), and nitrate-reducing bacteria (Rheinheimera sp. from the Alteromonadales), all of which likely contributed to nitrogen cycling processes at the cathode. This paper highlights the importance of coupling microbial community screening to electrochemical and chemical analyses to better understand the processes involved in photo-cathode MFCs.

  1. Treating domestic effluent wastewater treatment by aerobic biofilter with bioballs medium

    Science.gov (United States)

    Permatasari, R.; Rinanti, A.; Ratnaningsih, R.

    2018-01-01

    This laboratory scale research aimed to treat wastewater effluent with advanced treatment utilizing aerobic biofilter with bio-balls medium to obtain effluent quality in accordance with DKI Jakarta Governor Regulation No. 122 of 2005. The seeding and acclimatization were conducted in 4 weeks. The effluent were accommodated in a 150 L water barrel supported by a submersible pump. The effluent were treated in two boxes shaped reactors made of glasses with 36 L of each capacity. These reactors were equipped with aquarium aerators, sampling tap is 10 cm from the base of reactors, and bio-balls with 3 cm diameter are made of PVC. Reactors operated continuously with variations of retention time of 4 hours, 8 hours, 12 hours, 18 hours, and 24 hours and also variations of Carbon: Nitrogen: Phosphor = C: N: P ratio were, 100:5:1, 100:8:1, 100:10:1, 100:12:1, 100:15:1. The results showed that the optimum variance of retention time was 24 hours and the ratio of C:N:P was 100:10:1 yielded the largest removal efficiency for 83,33% of COD, 87,33% of BOD, 82,5% of Ammonia, 79,1% of Nitrate, 92% of Nitrite, 84,82% of Oil and Grease. The concentration parameter resulted from outlet biofilter has met the domestic wastewater quality standard of DKI Jakarta.

  2. Application of vertical flow constructed wetland in treatment of heavy metals from pulp and paper industry wastewater.

    Science.gov (United States)

    Arivoli, A; Mohanraj, R; Seenivasan, R

    2015-09-01

    The paper production is material intensive and generates enormous quantity of wastewater containing organic pollutants and heavy metals. Present study demonstrates the feasibility of constructed wetlands (CWs) to treat the heavy metals from pulp and paper industry effluent by using vertical flow constructed wetlands planted with commonly available macrophytes such as Typha angustifolia, Erianthus arundinaceus, and Phragmites australis. Results indicate that the removal efficiencies of the planted CWs for iron, copper, manganese, zinc, nickel, and cadmium were 74, 80, 60, 70, 71, and 70 %, respectively. On the other hand, the removal efficiency of the unplanted system was significantly lower ranging between 31 and 55 %. Among the macrophytes, T. angustifolia and E. arundinaceus exhibited comparatively higher bioconcentration factor (10(2) to 10(3)) than P. australis.

  3. Anaerobic treatment of blended sugar industry and ethanol distillery wastewater through biphasic high rate reactor.

    Science.gov (United States)

    Fito, Jemal; Tefera, Nurelegne; Kloos, Helmut; Van Hulle, Stijn W H

    2018-03-01

    This study aimed to investigate the physicochemical properties of sugar industry and ethanol distillery wastewater and the treatment of the blended wastewater through a two-stage anaerobic reactor. For this treatment, different initial chemical oxygen demand (COD) concentrations (5-20 g/L) and hydraulic retention times (HRTs) (2-10 days) were applied. The sugar industry effluent characteristics obtained in terms of organic matter (mg/L) were as follows: 5 days biochemical oxygen demand (BOD 5 ): 654.5-1,968; COD: 1,100-2,148.9; total solids (TS): 2,467-4,012 mg/L; and pH: 6.93-8.43. The ethanol distillery spent wash strengths obtained were: BOD 5 : 27,600-42,921 mg/L; COD: 126,000-167,534 mg/L; TS: 140,160-170,000 mg/L; and pH: 3.9-4.2. Maximum COD removal of 65% was obtained at optimum condition (initial COD concentration of 10 g/L and HRT of 10 days), and maximum color removal of 79% was recorded under similar treatment conditions. Hence, the performance of the two-stage anaerobic reactor for simultaneous removal of COD and color from high-strength blended wastewater is promising for scaling up in order to mitigate environmental problems of untreated effluent discharge.

  4. Industrial wastewater advanced treatment via catalytic ozonation with an Fe-based catalyst.

    Science.gov (United States)

    Li, Xufang; Chen, Weiyu; Ma, Luming; Wang, Hongwu; Fan, Jinhong

    2018-03-01

    An Fe-based catalyst was used as a heterogeneous catalyst for the ozonation of industrial wastewater, and key operational parameters (pH and catalyst dosage) were studied. The results indicated that the Fe-based catalyst significantly improved the mineralization of organic pollutants in wastewater. TOC (total organic carbon) removal was high, at 78.7%, with a catalyst concentration of 200 g/L, but only 31.6% with ozonation alone. The Fe-based catalyst significantly promoted ozone decomposition by 70% in aqueous solution. Hydroxyl radicals (·OH) were confirmed to be existed directly via EPR (electron paramagnetic resonance) experiments, and ·OH were verified to account for about 34.4% of TOC removal with NaHCO 3 as a radical scavenger. Through characterization by SEM-EDS (field emission scanning electron microscope with energy-dispersive spectrometer), XRD (X-ray powder diffraction) and XPS (X-ray photoelectron spectroscopy), it was deduced that FeOOH on the surface of the catalyst was the dominant contributor to the catalytic efficiency. The catalyst was certified as having good stability and excellent reusability based on 50 successive operations and could be used as a filler simultaneously. Thereby, it is a promising catalyst for practical industrial wastewater advanced treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Heavy metal input to agricultural soils from irrigation with treated wastewater: Insight from Pb isotopes

    Science.gov (United States)

    Kloppmann, Wolfram; Cary, Lise; Psarras, Georgios; Surdyk, Nicolas; Chartzoulakis, Kostas; Pettenati, Marie; Maton, Laure

    2010-05-01

    A major objective of the EU FP6 project SAFIR was to overcome certain drawbacks of wastewater reuse through the development of a new irrigation technology combining small-scale modular water treatment plants on farm level and improved irrigation hardware, in the aim to lower the risks related to low quality water and to increase water use efficiency. This innovative technology was tested in several hydro-climatic contexts (Crete, Italy, Serbia, China) on experimental irrigated tomato and potato fields. Here we present the heavy metal variations in soil after medium-term (3 irrigation seasons from 2006-2008) use of treated municipal wastewater with a special focus on lead and lead isotope signatures. The experimental site is located in Chania, Crete. A matrix of plots were irrigated, combining different water qualities (secondary, primary treated wastewater, tap water, partially spiked with heavy metals, going through newly developed tertiary treatment systems) with different irrigation strategies (surface and subsurface drip irrigation combined with full irrigation and partial root drying). In order to assess small scale heavy metal distribution around a drip emitter, Pb isotope tracing was used, combined with selective extraction. The sampling for Pb isotope fingerprinting was performed after the 3rd season of ww-irrigation on a lateral profile from a drip irrigator (half distance between drip lines, i.e. 50cm) and three depth intervals (0-10, 10-20, 20-40 cm). These samples were lixiviated through a 3 step selective extraction procedure giving rise to the bio-accessible, mobile and residual fraction: CaCl2/NaNO3 (bio-accessible fraction), DPTA (mobile fraction), total acid attack (residual fraction). Those samples were analysed for trace elements (including heavy metals) and major inorganic compounds by ICP-MS. The extracted fractions were then analysed by Thermal Ionisation Mass Spectrometry (TIMS) for their lead isotope fingerprints (204Pb, 206Pb, 207Pb, 208Pb

  6. Treated wastewater and Nitrate transport beneath irrigated fields near Dodge city, Kansas

    Science.gov (United States)

    Sophocleous, M.; Townsend, M.A.; Vocasek, F.; Ma, Liwang; Ashok, K.C.

    2010-01-01

    Use of secondary-treated municipal wastewater for crop irrigation south of Dodge City, Kansas, where the soils are mainly of silty clay loam texture, has raised a concern that it has resulted in high nitratenitrogen concentrations (10-50 mg/kg) in the soil and deeper vadose zone, and also in the underlying deep (20-45 m) ground water. The goal of this field-monitoring project was to assess how and under what circumstances nitrogen (N) nutrients under cultivated corn that is irrigated with this treated wastewater can reach the deep ground water of the underlying High Plains aquifer, and what can realistically be done to minimize this problem. We collected 15.2-m-deep cores for physical and chemical properties characterization; installed neutron moisture-probe access tubes and suction lysimeters for periodic measurements; sampled area monitoring, irrigation, and domestic wells; performed dye-tracer experiments to examine soil preferential-flow processes through macropores; and obtained climatic, crop, irrigation, and N-application rate records. These data and additional information were used in the comprehensive Root Zone Water Quality Model (RZWQM2) to identify key parameters and processes that influence N losses in the study area. We demonstrated that nitrate-N transport processes result in significant accumulations of N in the thick vadose zone. We also showed that nitrate-N in the underlying ground water is increasing with time and that the source of the nitrate is from the wastewater applications. RZWQM2 simulations indicated that macropore flow is generated particularly during heavy rainfall events, but during our 2005-06 simulations the total macropore flow was only about 3% of precipitation for one of two investigated sites, whereas it was more than 13% for the other site. Our calibrated model for the two wastewater-irrigated study sites indicated that reducing current levels of corn N fertilization by half or more to the level of 170 kg/ha substantially

  7. Application of Emergy Analysis to the Sustainability Evaluation of Municipal Wastewater Treatment Plants

    OpenAIRE

    Shuai Shao; Hailin Mu; Fenglin Yang; Yun Zhang; Jinhua Li

    2016-01-01

    Municipal wastewater treatment plants consume much energy and manpower, are expensive to run, and generate sludge and treated wastewater whilst removing pollutants through specific treatment regimes. The sustainable development of the wastewater treatment industry is therefore challenging, and a comprehensive evaluation method is needed for assessing the sustainability of different wastewater treatment processes, for identifying the improvement potential of treatment plants, and for directing...

  8. Monitoring as a tool for the assessment of wastewater quality dynamics

    NARCIS (Netherlands)

    Schilperoort, R.P.S.

    2011-01-01

    The wastewater system in the Netherlands comprises approximately 100,000 km of sewer pipes and more than 350 wastewater treatment plants (wwtp). The system collects and treats the majority of domestic and industrial wastewater. A small amount of untreated wastewater, however, is occasionally

  9. Radiation processing of wastewater

    International Nuclear Information System (INIS)

    2007-01-01

    Rapid population growth and increased agricultural and industrial development have led to the generation of large quantities of polluted industrial and municipal wastewaters. The recognition that these polluted waters may pose a serious threat to humans has led technologists to seek cost effective technologies for their treatment. A variety of methods based on biological. chemical. photochemical and electrochemical processes are being explored for decomposing the chemical and biological contaminants present in these wastewaters. Radiation technologists have been investigating the use of high energy radiation for their treatment. The primary advantage of radiation processing over alternatives is that the reactive species are generated in situ during the radiolysis process without the addition of any chemicals. Several pilot scale and a number of industrial scale wastewater treatment plants based on radiation technology are in operation or under construction. The results of practical applications have confirmed that radiation technology can be easily and effectively utilized for treating large quantities ol wastewater

  10. Removal of boron from ceramic industry wastewater by adsorption-flocculation mechanism using palm oil mill boiler (POMB) bottom ash and polymer.

    Science.gov (United States)

    Chong, Mei Fong; Lee, Kah Peng; Chieng, Hui Jiun; Syazwani Binti Ramli, Ili Izyan

    2009-07-01

    Boron is extensively used in the ceramic industry for enhancing mechanical strength of the tiles. The discharge of boron containing wastewater to the environment causes severe pollution problems. Boron is also dangerous for human consumption and causes organisms' reproductive impediments if the safe intake level is exceeded. Current methods to remove boron include ion-exchange, membrane filtration, precipitation-coagulation, biological and chemical treatment. These methods are costly to remove boron from the wastewater and hence infeasible for industrial wastewater treatment. In the present research, adsorption-flocculation mechanism is proposed for boron removal from ceramic wastewater by using Palm Oil Mill Boiler (POMB) bottom ash and long chain polymer or flocculant. Ceramic wastewater is turbid and milky in color which contains 15 mg/L of boron and 2000 mg/L of suspended solids. The optimum operating conditions for boron adsorption on POMB bottom ash and flocculation using polymer were investigated in the present research. Adsorption isotherm of boron on bottom ash was also investigated to evaluate the adsorption capacity. Adsorption isotherm modeling was conducted based on Langmuir and Freundlich isotherms. The results show that coarse POMB bottom ash with particle size larger than 2 mm is a suitable adsorbent where boron is removed up to 80% under the optimum conditions (pH=8.0, dosage=40 g bottom ash/300 ml wastewater, residence time=1h). The results also show that KP 1200 B cationic polymer is effective in flocculating the suspended solids while AP 120 C anionic polymer is effective in flocculating the bottom ash. The combined cationic and anionic polymers are able to clarify the ceramic wastewater under the optimum conditions (dosage of KP 1200 B cationic polymer=100 mg/L, dosage of AP 120 C anionic polymer=50 mg/L, mixing speed=200 rpm). Under the optimum operating conditions, the boron and suspended solids concentration of the treated wastewater were

  11. Treatment of food-agro (sugar industry wastewater with copper metal and salt: Chemical oxidation and electro-oxidation combined study in batch mode

    Directory of Open Access Journals (Sweden)

    Anurag Tiwari

    2017-06-01

    Full Text Available Sugar industry is one of the major industries which have been included in the polluting industries list by the World Bank. Different pollution monitoring agencies like State and National Pollution Control Boards have been made compulsory for each industry to set up a waste water treatment plants. In treatment system, single treatments of effluent are not effective to manage the dischargeable limit. So an attempted has been made to treat sugar industry wastewater with electrochemical and chemical process by using copper as electrode and chemical. Electrochemical process shows 81% chemical oxygen demand and 83.5% color reduction at pH 6, electrode distance 20 mm, current density 178 A m−2 and 120 min treatment time. The combined treatment results show 98% chemical oxygen demand and 99.5% color removal at 8 mM mass loading and pH 6 with copper sulphate.

  12. Why use a thermophilic aerobic membrane reactor for the treatment of industrial wastewater/liquid waste?

    Science.gov (United States)

    Collivignarelli, Maria Cristina; Abbà, Alessandro; Bertanza, Giorgio

    2015-01-01

    This paper describes the advantages of thermophilic aerobic membrane reactor (TAMR) for the treatment of high strength wastewaters. The results were obtained from the monitoring of an industrial and a pilot scale plant. The average chemical oxygen demand (COD) removal yield was equal to 78% with an organic loading rate (OLR) up to 8-10 kgCOD m(-3) d(-1) despite significant scattering of the influent wastewater composition. Total phosphorus (TP) was removed with a rate of 90%, the most important removal mechanism being chemical precipitation (as hydroxyapatite, especially), which is improved by the continuous aeration that promotes phosphorus crystallization. Moreover, surfactants were removed with efficiency between 93% and 97%. Finally, the experimental work showed that thermophilic processes (TPPs) are complementary with respect to mesophilic treatments.

  13. A combined electrocoagulation-sorption process applied to mixed industrial wastewater

    International Nuclear Information System (INIS)

    Linares-Hernandez, Ivonne; Barrera-Diaz, Carlos; Roa-Morales, Gabriela; Bilyeu, Bryan; Urena-Nunez, Fernando

    2007-01-01

    The removal of organic pollutants from a highly complex industrial wastewater by a aluminium electrocoagulation process coupled with biosorption was evaluated. Under optimal conditions of pH 8 and 45.45 A m -2 current density, the electrochemical method yields a very effective reduction of all organic pollutants, this reduction was enhanced when the biosorption treatment was applied as a polishing step. Treatment reduced chemical oxygen demand (COD) by 84%, biochemical oxygen demand (BOD 5 ) by 78%, color by 97%, turbidity by 98% and fecal coliforms by 99%. The chemical species formed in aqueous solution were determined. The initial and final pollutant levels in the wastewater were monitored using UV-vis spectrometry and cyclic voltammetry. Finally, the morphology and elemental composition of the biosorbent was characterized with scanning electron microscopy (SEM) and energy dispersion spectra (EDS)

  14. Management Recommendations for Improving Decentralized Wastewater Treatment by the Food and Beverage Industries in Nigeria

    Directory of Open Access Journals (Sweden)

    Olajumoke F. Kayode

    2018-03-01

    Full Text Available The main aim of this study was to identify the enabling conditions that can lead to better wastewater management by industries (non-oil and gas sector in Nigeria. The relevant data and information’s required for this study were obtained through semi-structured interviews with different stakeholders in the Nigerian environmental sector. The lack of financial capability, technical expertise, and environmental awareness was envisaged as the main reason for non-compliance. According to the results, the enabling conditions that can lead to better decentralized wastewater management are government support, improved legal and regulatory framework, increased capacity, and skills of the regulators and financial arrangements for implementing environmental policies and treatment technologies in polluting facilities.

  15. Evaluation of waste activated sludge as a coagulant aid for the treatment of industrial wastewater containing mixed surfactants.

    Science.gov (United States)

    Sriwiriyarat, Tongchai; Jangkorn, Siriprapha

    2009-04-01

    Wastewater generated by the industry manufacturing detergents and various kinds of consumer products normally contains very high contents of mixed surfactants, organic matters expressed as chemical oxygen demand (COD), and phosphates that must be treated prior to discharge to the aquatic environment. In this study, jar-test experiments were conducted to evaluate the waste activated sludge (WAS) as a coagulation aid in the coagulation-flocculation process with ferric chloride or aluminum sulfate as a coagulant for the treatment of wastewater collected from the aforementioned industry. The WAS was selected because of its adsorption capability of anionic surfactants and its availability from the wastage stream of biological wastewater treatment process. The effective dosages of both coagulants with and without the WAS additions were determined in this study. Without the WAS addition, the concentrations of 800 mg/L aluminum sulfate at the optimum pH value of 8 and 2208 mg/L ferric chloride at the optimum pH value of 12 were the optimum chemical dosages. It appears that aluminum sulfate was more effective than ferric chloride based on the chemical dosage and removal efficiency. The turbidity, suspended particles, anionic surfactants, COD, and phosphates removal efficiencies of aluminum sulfate and ferric chloride under the optimum dosage were 95.6, 88.2, 78.4, 73.5, 47.3% and 98.8, 92.0, 72.7, 67.5, 53.1%, respectively. The addition of 200 mg/L WAS was sufficient to reduce the optimum dosages of both chemicals by 200 mg/L. The cationic surfactant existing in the wastewater worked as a flocculating agent leading to the flocculation of waste activated sludge resulting in the enmeshment of the suspended particles and colloids on which the COD, anionic surfactants, and phosphates were adsorbed. However, the substances removal efficiencies of ferric chloride and aluminum sulfate were slightly enhanced and reduced, respectively. It is possibly explained that the settling time

  16. Improvement Bio sorption of Heavy Metals from Industrial Wastewater Using Azolla

    International Nuclear Information System (INIS)

    Kotb, E.A.

    2012-01-01

    This study aims to improve the removal process which is vital for some heavy metals and natural radionuclides from industrial wastewater by bio sorption using living organisms with rapid growth as a trial to increase the efficient use of those organisms in the removal process is vital for the toxic elements. Bio sorption of heavy metal (Copper, Manganese, Iron, Zinc, Lead and Strontium) from industrial waste water (contaminated) with six different time periods for Azolla growth. The results indicate that Azolla plant able to on the absorption of ions of heavy elements and Sr and was up to the maximum absorption of most of the elements at a concentration of 50% of polluted water + 50% fresh water so we recommend using the plant Azolla as bio sorbent in the disposal and collection of heavy metals and radionuclides from industrial waste water and deal with it safely to humans and the environment. The results obtained confirm the ability of the fern to grow and absorb ion of heavy metal when mixed with industrial waste water and other sources of polluted water and act as bio filter. The optimum conditions for maximum removal of heavy metals were also determined. Study was conducted on recycling municipal wastewaters for cultivation of Azollamicrophylla biomass, which is used for inoculation into paddy fields as N bio fertilizer and has other applications as green manure,animal feed and bio filter.

  17. A novel image processing-based system for turbidity measurement in domestic and industrial wastewater.

    Science.gov (United States)

    Mullins, Darragh; Coburn, Derek; Hannon, Louise; Jones, Edward; Clifford, Eoghan; Glavin, Martin

    2018-03-01

    Wastewater treatment facilities are continually challenged to meet both environmental regulations and reduce running costs (particularly energy and staffing costs). Improving the efficiency of operational monitoring at wastewater treatment plants (WWTPs) requires the development and implementation of appropriate performance metrics; particularly those that are easily measured, strongly correlate to WWTP performance, and can be easily automated, with a minimal amount of maintenance or intervention by human operators. Turbidity is the measure of the relative clarity of a fluid. It is an expression of the optical property that causes light to be scattered and absorbed by fine particles in suspension (rather than transmitted with no change in direction or flux level through a fluid sample). In wastewater treatment, turbidity is often used as an indicator of effluent quality, rather than an absolute performance metric, although correlations have been found between turbidity and suspended solids. Existing laboratory-based methods to measure turbidity for WWTPs, while relatively simple, require human intervention and are labour intensive. Automated systems for on-site measuring of wastewater effluent turbidity are not commonly used, while those present are largely based on submerged sensors that require regular cleaning and calibration due to fouling from particulate matter in fluids. This paper presents a novel, automated system for estimating fluid turbidity. Effluent samples are imaged such that the light absorption characteristic is highlighted as a function of fluid depth, and computer vision processing techniques are used to quantify this characteristic. Results from the proposed system were compared with results from established laboratory-based methods and were found to be comparable. Tests were conducted using both synthetic dairy wastewater and effluent from multiple WWTPs, both municipal and industrial. This system has an advantage over current methods as it

  18. Corn industrial wastewater (nejayote): a promising substrate in Mexico for methane production in a coupled system (APCR-UASB).

    Science.gov (United States)

    España-Gamboa, Elda; Domínguez-Maldonado, Jorge Arturo; Tapia-Tussell, Raul; Chale-Canul, Jose Silvano; Alzate-Gaviria, Liliana

    2018-01-01

    In Mexico, the corn tortilla is a food of great economic importance. Corn tortilla production generates about 1500-2000 m 3 of wastewater per 600 tons of processed corn. Although this wastewater (also known as nejayote) has a high organic matter content, few studies in Mexico have analyzed its treatment. This study presents fresh data on the potential methane production capacity of nejayote in a two-phase anaerobic digestion system using an Anaerobic-Packed Column Reactor (APCR) to optimize the acidogenic phase and an up-flow anaerobic sludge blanket (UASB) reactor to enhance the methanogenic process. Results indicate that day 8 was ideal to couple the APCR to the UASB reactor. This allowed for a 19-day treatment that yielded 96% COD removal and generated a biogas containing 84% methane. The methane yield was 282 L kg -1 of COD removed . Thus, two-phase anaerobic digestion is an efficient process to treat nejayote; furthermore, this study demonstrated the possibility of using an industrial application by coupling the APCR to the UASB reactor system, in order to assess its feasibility for biomethane generation as a sustainable bioenergy source.

  19. Effluent quality of a conventional activated sludge and a membrane bioreactor system treating hospital wastewater

    International Nuclear Information System (INIS)

    Pauwels, B.; Ngwa, F.; Deconinck, S.; Verstraete, W.

    2005-01-01

    Two lab scale wastewater treatment plants treating hospital wastewater in parallel were compared in terms of performance characteristics. One plant consisted of a conventional activated sludge system (CAS) and comprised In anoxic and aerobic compartment followed by a settling tank with recycle loop. The second pilot plant was a -late membrane bioreactor (MBR). The wastewater as obtained from the hospital had a variable COD (Chemical Oxygen Demand) ranging from 250 to 2300 mg/L. Both systems were operated at a similar hydraulic residence time of 12 hours. The reference conventional activated sludge system did not meet the regulatory standard for effluent COD of 125 mg /L most of the time. Its COD removal efficiency was 88%. The plate MBR delivered an effluent with a COD value of 50 mg/L or less, and attained an efficiency of 93%. The effluent contained no suspended particles. In addition, the MBR resulted in consistent operational parameters with a flux remaining around 8 -10 L/m/sup 2/.h and a trans membrane pressure <0.1 bar without the need for backwash or chemical cleaning. The CAS and the MBR system performed equally good in terms of TAN removal and EE2 removal. The CAS system typically decreased bacterial groups for about 1 log unit, whereas the MBR decreased these groups for about 3 log units. Enterococci were decreased below the detection limit in the MBR and indicator organisms such as fecal coliforms were decreased for 1.4 log units in the CAS system compared to a 3.6 log removal in the MBR. (author)

  20. Heterotroph anoxic yield in anoxic aerobic activated sludge systems treating municipal wastewater.

    Science.gov (United States)

    Muller, A; Wentzel, M C; Loewenthal, R E; Ekama, G A

    2003-05-01

    As input to the steady state design and kinetic simulation models for the activated sludge system, the correct value for the heterotroph anoxic yield is essential to provide reliable estimates for the system denitrification potential. This paper examines activated sludge anoxic yield values in the literature, and presents experimental data quantifying the value. In the literature, in terms of the structure of ASM1 and similar models, theoretically it has been shown that the anoxic yield should be reduced to approximately 0.79 the value of the aerobic yield. This theoretical value is validated with data from corresponding aerobic OUR and anoxic nitrate time profiles in a batch fed laboratory scale long sludge age activated sludge system treating municipal wastewater. The value also is in close agreement with values in the literature measured with both artificial substrates and municipal wastewater. Thus, it is concluded that, in ASM1 and similar models, for an aerobic yield of 0.67mg COD/mg COD, the anoxic yield should be about 0.53 mg COD/mg COD. Including such a lower anoxic yield in ASM1 and similar models will result in a significant increase in denitrification potential, due to increased denitrification with wastewater RBCOD as substrate. In terms of the structure of ASM3, for the proposed substrate storage yields and the aerobic yield of 0.63 mg COD/mg COD, experimental data indicate that the corresponding anoxic yield should be about 0.42 mg COD/mg COD. This is significantly lower than the proposed value of 0.54 mg COD/mg COD, and requires further investigation.

  1. Performance evaluation of full scale UASB reactor in treating stillage wastewater

    Directory of Open Access Journals (Sweden)

    A.Mirsepasi , H. R. Honary , A. R. Mesdaghinia, A. H. Mahvi , H. Vahid , H. Karyab

    2006-04-01

    Full Text Available Upflow anaerobic sludge blanket (UASB reactors have been widely used for treatment of industrial wastewater. In this study two full-scale UASB reactors were investigated. Volume of each reactor was 420 m3. Conventional parameters such as pH, temperature and efficiency of COD, BOD, TOC removal in each reactor were investigated. Also several initial parameters in designing and operating of UASB reactors, such as upflow velocity, organic loading rate (OLR and hydraulic retention time were investigated. After modifying in operation conditions in UASB-2 reactor, average COD removal efficiency at OLR of 10–11 kg COD / m3 day was 55 percent. In order to prevent solids from settling, upflow velocity was increased to 0.35 m/h. Also to prevent solids from settling, the hydraulic retention time of wastewater in UASB-2 reactor was increased from 200 to 20 hours. This was expected that with good operation of UASB-2 reactor and with expanding of granules in the bed of the reactor, COD removal efficiency will be increased to more than 80 percent. But, because of deficiency on granulation and operation in UASB-2 reactor, this was not achieved. COD removal efficiency in the UASB-1 reactor was little. To enhance COD efficiency of UASB-1 reactor, several parameters were needed to be changed. These changes included enhancing of OLRs and upflow velocity, decreasing hydraulic retention time and operating with new sludge.

  2. Combined organic matter and nitrogen removal from a chemical industry wastewater in a two-stage MBBR system.

    Science.gov (United States)

    Cao, S M S; Fontoura, G A T; Dezotti, M; Bassin, J P

    2016-01-01

    Pesticide-producing factories generate highly polluting wastewaters containing toxic and hazardous compounds which should be reduced to acceptable levels before discharge. In this study, a chemical industry wastewater was treated in a pre-denitrification moving-bed biofilm reactor system subjected to an increasing internal mixed liquor recycle ratio from 2 to 4. Although the influent wastewater characteristics substantially varied over time, the removal of chemical oxygen demand (COD) and dissolved organic carbon was quite stable and mostly higher than 90%. The highest fraction of the incoming organic matter was removed anoxically, favouring a low COD/N environment in the subsequent aerobic nitrifying tank and thus ensuring stable ammonium removal (90-95%). However, during pH and salt shock periods, nitrifiers were severely inhibited but gradually restored their full nitrifying capability as non-stressing conditions were reestablished. Besides promoting an increase in the maximum nitrification potential of the aerobic attached biomass from 0.34 to 0.63 mg [Formula: see text], the increase in the internal recycle ratio was accompanied by an increase in nitrogen removal (60-78%) and maximum specific denitrification rate (2.7-3.3 mg NOx(-)--N). Total polysaccharides (PS) and protein (PT) concentrations of attached biomass were observed to be directly influenced by the influent organic loading rate, while the PS/PT ratio mainly ranged from 0.3 to 0.5. Results of Microtox tests showed that no toxicity was found in the effluent of both the anoxic and aerobic reactors, indicating that the biological process was effective in removing residual substances which might adversely affect the receiving waters' ecosystem.

  3. Production of citric acid using its extraction wastewater treated by anaerobic digestion and ion exchange in an integrated citric acid-methane fermentation process.

    Science.gov (United States)

    Xu, Jian; Chen, Yang-Qiu; Zhang, Hong-Jian; Tang, Lei; Wang, Ke; Zhang, Jian-Hua; Chen, Xu-Sheng; Mao, Zhong-Gui

    2014-08-01

    In order to solve the problem of extraction wastewater pollution in citric acid industry, an integrated citric acid-methane fermentation process is proposed in this study. Extraction wastewater was treated by mesophilic anaerobic digestion and then used to make mash for the next batch of citric acid fermentation. The recycling process was done for seven batches. Citric acid production (82.4 g/L on average) decreased by 34.1 % in the recycling batches (2nd-7th) compared with the first batch. And the residual reducing sugar exceeded 40 g/L on average in the recycling batches. Pigment substances, acetic acid, ammonium, and metal ions in anaerobic digestion effluent (ADE) were considered to be the inhibitors, and their effects on the fermentation were studied. Results indicated that ammonium, Na(+) and K(+) in the ADE significantly inhibited citric acid fermentation. Therefore, the ADE was treated by acidic cation exchange resin prior to reuse to make mash for citric acid fermentation. The recycling process was performed for ten batches, and citric acid productions in the recycling batches were 126.6 g/L on average, increasing by 1.7 % compared with the first batch. This process could eliminate extraction wastewater discharge and reduce water resource consumption.

  4. The effect of organic load and feed strategy on biohydrogen production in an AnSBBR treating glycerin-based wastewater.

    Science.gov (United States)

    Lovato, G; Moncayo Bravo, I S; Ratusznei, S M; Rodrigues, J A D; Zaiat, M

    2015-05-01

    An anaerobic sequencing batch biofilm reactor (AnSBBR) with recirculation of the liquid phase (at 30 °C with 3.5 L of working volume and treating 1.5 L per cycle) treating pure glycerin-based wastewater was applied to biohydrogen production. The applied volumetric organic load (AVOL) ranged from 7.7 to 17.1 kgCOD m(-3) d(-1), combining different influent concentrations (3000, 4000 and 5000 mgCOD L(-1)) and cycle lengths (4 and 3 h). The feed strategy used was to maintain the feeding time equal to half of the cycle time. The increase in the influent concentration and the decrease in cycle length improved the molar yield and molar productivity of hydrogen. The highest productivity (100.8 molH2 m(-3) d(-1)) and highest yield of hydrogen per load removed (20.0 molH2 kgCOD(-1)) were reached when the reactor operated with an AVOL of 17.1 kgCOD m(-3) d(-1), with 68% of H2 and only 3% of CH4 in its biogas. It was also found that pretreatment of the sludge/inoculum does not influence the productivity/yield of the process and the use of crude industrial glycerin-based wastewater in relation to the pure glycerol-based wastewater substantially decreased the production and composition of the hydrogen produced. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Obstruction and uniformity in drip irrigation systems by applying treated wastewater

    Directory of Open Access Journals (Sweden)

    Patrícia Ferreira da Silva

    Full Text Available ABSTRACT The use of wastewater in agriculture is an alternative to control surface water pollution, and helps to promote the rational use of water. Therefore, the objective of this study was to evaluate the obstruction and uniformity of application of treated wastewater in drip irrigation systems. The study was conducted in a greenhouse at the Universidade Federal de Campina Grande. The treatments were composed by the factorial combination of two factors: three types of water (supply water-ABAST, effluent of a constructed wetland system -WETLAND and upflow of anaerobic reactor effluent followed by constructed wetland system -UASB + WETLAND, and two drip irrigation systems (surface and subsurface, set in a completely randomized design, with four replications. The results indicated that the pH, suspended solids, total iron and coliforms of the WETLAND and UASB + WETLAND treatments represented a severe risk of clogging of drippers; the flow of the emitters increased as the service pressure was increased; values of CUC and CUD in surface and subsurface drip were classified as excellent in ABAST and WETLAND treatments. The degree of clogging reduced as pressure under surface and subsurface drip was increased.

  6. Removal of chromium(VI) from wastewater using phosphoric acid treated activated carbon

    Science.gov (United States)

    Suganthi, N.

    2013-06-01

    Activated carbon prepared by phosphoric acid treatment of tamarind nuts (seeds) was investigated for the removal of Cr(VI) from aqueous solutions. The characteristics of phosphorylated tamarind nut carbon (PTNC) were evaluated for porosity and surface area. The effect of contact time, pH, adsorbent dose and particle size variation were studied to evaluate the potential applicability of carbon for treating Cr(VI) containing wastewater. The adsorbent data were modeled by Langmiur and Freundlich classical adsorption isotherms. The kinetic studies showed that Cr(VI) adsorption on PTNC was in compliance with the pseudo-second-order kinetic model. Desorption studies indicated that ion-exchange mechanism was operating. The continuous adsorption was studied in glass columns of 2.5 cm diameter using electroplating wastewater to ascertain the practical applicability of PTNC in large scale. The mechanism of adsorption was found to be ion-exchange process and was supported by FTIR spectroscopy. The surface modification after adsorption was confirmed by SEM studies.

  7. Performance of suspended and attached growth MBR systems in treating high strength synthetic wastewater.

    Science.gov (United States)

    Jamal Khan, S; Ilyas, Shazia; Javid, Sadaf; Visvanathan, C; Jegatheesan, V

    2011-05-01

    The performance of laboratory-scale attached growth (AG) and suspended growth (SG) membrane bioreactors (MBRs) was evaluated in treating synthetic wastewater simulating high strength domestic wastewater. This study investigated the influence of sponge suspended carriers in AG-MBR system, occupying 15% reactor volume, on the removal of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP), and compared it to that of SG-MBR. Results showed that the removal efficiencies of COD, TN and TP in AG-MBR were 98%, 89% and 58%, respectively as compared to 98%, 74% and 38%, respectively in SG-MBR. Improved TN removal in AG-MBR systems was primarily based on simultaneous nitrification and denitrification (SND) process. These results infer that the presence of small bio-particles having higher microbial activity and the growth of complex biomass captured within the suspended sponge carriers resulted in improved TN and TP removal in AG-MBR. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. OPTIMISATION OF HIBISCUS SABDARIFFA AS A NATURAL COAGULANT TO TREAT CONGO RED IN WASTEWATER

    Directory of Open Access Journals (Sweden)

    MUN Y. YONG

    2016-02-01

    Full Text Available The process of coagulation is commonly practiced in water and wastewater treatment to reduce level of dissolved chemical, turbidity and so on with the usage of coagulant. Aluminium sulphate (alum is the most commonly used coagulant, however, recent studies show that residual aluminium in drinking water and sludge may induce Alzheimer’s disease and environmental issues. Natural coagulant which is environmental friendly and non-toxic is developed as an alternative to overcome these issues. In this work, Hibiscus Sabdariffa was studied as natural coagulant to treat dye wastewater containing Congo red. The seeds were extracted with different solvent such as distilled water, 0.5 M NaCl and 0.05 M NaOH to extract the coagulation agent. The working parameters were optimised using Response Surface Methodology (RSM. 0.5 M NaCl was found to have highest colour removal of 95.1 % among the solvents. In addition, Hibiscus Sabdariffa seed was found to be an effective coagulant that has 91.2 % colour removal at the optimal working condition of pH 2, 190 mg/L coagulant dosage at 400 ppm of dye concentration. It was also been identified that the performance of natural coagulant is comparable with conventional coagulant, aluminium sulphate with colour removal of 91.2 % and 92.3 % respectively.

  9. Use of horizontal subsurface flow constructed wetlands to treat reverse osmosis concentrate of rolling wastewater.

    Science.gov (United States)

    Xu, Jingcheng; Zhao, Gang; Huang, Xiangfeng; Guo, Haobo; Liu, Wei

    2017-03-04

    According to the characteristics of the reverse osmosis concentrate (ROC) generated from iron and steel company, we used three sets of parallel horizontal subsurface flow (HSF) constructed wetlands (CWs) with different plants and substrate layouts to treat the high-salinity wastewater. The plant growth and removal efficiencies under saline condition were evaluated. The evaluation was based entirely on routinely collected water quality data and the physical and chemical characteristics of the plants (Phragmites australis, Typha latifolia, Iris wilsonii, and Scirpus planiculmis). The principal parameters of concern in the effluent were chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP). The results showed that the CWs were able to remove COD, TN, and TP from ROC. S. planiculmis was not suitable for the treatment of high-saline wastewater. The sequence of metals accumulated in CW plants was K>Ca>Na>Mg>Zn>Cu. More than 70% of metals were accumulated in the aboveground of P. australis. The CW filled with gravel and manganese ore and planted with P. australis and T. latifolia had the best performance of pollutant removal, with average removal of 49.96%, 39.45%, and 72.01% for COD, TN, and TP, respectively. The effluent water quality met the regulation in China. These results suggested that HSF CW planted with P. australis and T. latifolia can be applied for ROC pollutants removal.

  10. UHPLC-QTOF MS screening of pharmaceuticals and their metabolites in treated wastewater samples from Athens.

    Science.gov (United States)

    Ibáñez, M; Borova, V; Boix, C; Aalizadeh, R; Bade, R; Thomaidis, N S; Hernández, F

    2017-02-05

    After consumption, pharmaceuticals are excreted as parent compounds and/or metabolites in urine and faeces. Some are not completely removed during wastewater treatments, forcing sewage treatment plants (STPs) to apply alternative technologies to guarantee quality of treated water. To monitor the removal efficiency of STPs, not only unchanged compounds and metabolites have to be taken into account, but also formation of possible transformation products (TPs). In this work, QTOF MS has been used for screening metabolites/TPs of pharmaceuticals in effluent wastewater from Athens. A customised database was built with the exact masses of metabolites reported in literature for the parent drugs found in an initial screening. Additionally, TPs identified in previous degradation experiments performed at our laboratory were included. Up to 34 metabolites/TPs were detected for omeprazole, venlafaxine, clindamycin, clarithromycin, clopidogrel or dipyrone, among others. Seven corresponded to TPs whose reference standards were available at our lab, seven were TPs previously identified in laboratory degradation experiments, eight were TPs tentatively identified by QTOF MS without reference standards, and twelve TPs were discovered after using the common fragmentation pathway approach. Tentative identification of TPs was supported by prediction of their chromatographic retention time based on the use of advanced chemometric QSRR models. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Molecular weight distribution of Pinus radiata kraft mill wastewater treated by anaerobic digestion.

    Science.gov (United States)

    Vidal, G; Videla, S; Diez, M C

    2001-04-01

    Kraft mill is responsible for massive discharge of highly polluted effluents. The main characteristics of this effluent are high toxicity and low biodegradability due to tannin, lignin and chlorophenol compounds. The composition may vary dramatically depending, for instance, on the utilised feedstock and process. The purpose of this work was to investigate the molecular weight distribution of Pinus radiata kraft pulping wastewater treated by anaerobic digestion by using two types of anaerobic reactors: fixed bed and sludge blanket. Anaerobic sludge blanket (UASB) and anaerobic filter (AF) were operated. In both reactors, the total alkalinity ranged between 1.0 and 1.5 g CaCO3/l, while the organic load rate (OLR) was increasing during operation from 1.2 to 3.3 gCOD/l d. COD and total phenolic compounds (UV215) removal ranged between 30-50% and 13-20%, respectively, while the BOD5 removal ranged 60-90%. However only a partial biodegradation (10-43%) of tannin and lignin was observed. Results from ultrafiltration analyses indicated that the fraction with a molecular weight (MW) 10,000 MW fraction, colour and COD fraction increased by 14% and 5%, respectively, after anaerobic treatment. It can be concluded from this study, that treatment with UASB or AF reactors is not enough, under the conditions tested, for a large COD removal from Pinus radiata wastewater.

  12. Use of cattails in treating wastewater from a Pb/Zn mine

    Science.gov (United States)

    Lan, Chongyu; Chen, Guizhu; Li, Liuchun; Wong, M. H.

    1992-01-01

    This article describes the use of a combined treatment system, which includes an aquatic treatment pond with Typha latifolia Linn. (Typhaceae) as the dominant species and a stabilization pond, to treat the wastewater from a Pn/Zn mine at Shaoguan, Guangdong Province, China. In 1983, it was noted that T. latifolia bloomed in areas affected by the wastewater emitted from the mine, hence a combined purification system was subsequently built. The influent contained high levels of total suspended solids (4635 mg/liter), chemical oxygen demand (14.5 mg/liter) as well as Pb (1.6 mg/liter) and Zn (1.9 mg/liter). The results of the effluent after treatment showed that the total suspended solids, chemical oxygen demand, Pb, and Zn had been reduced by 99%, 55%, 95%, and 80% respectively. The results of plant tissue analysis indicled that T. latifolia assimilated significant amounts of Pb and Zn, especially in the root portion. During 1986 several species of algae and fish were present in the pond, usually with a higher density in areas containing lower metal concentrations in the water.

  13. Combination of TiO2-Film Photocatalysis and Ultrafiltration to Treat Wastewater

    Directory of Open Access Journals (Sweden)

    Shu-Hai You

    2013-01-01

    Full Text Available In this study, a combination of TiO2-film photocatalysis reactor and ultrafiltration was used treat the secondary effluent from the manufacturing of thin film transistor-liquid crystal display (TFT-LCD. TiO2 particles, as a photocatalyst, were immobilized on silica glass to form TiO2-film by the sol-gel and dip coating methods. TiO2-film photocatalysis was done within three parameters, including number of coating times of TiO2-film, wavelengths of UV light source, and operating time. During ultrafiltration, the operating pressure and feed water temperature were controlled at 300 KN/m2 and 25°C, respectively. It was found that TiO2-film photocatalysis followed by ultrafiltration increased the removal of total organic carbon (TOC to 47.13% and 49.94% for 5 KDa and 10 KDa membranes, respectively. It was also found that the process increased the permeate flux rate (ca 23% for 10 KDa membrane after 6 hours of operation, since some larger organic matter had been broken into small organic matter and some small organic matter had been mineralized into CO2 following TiO2-film photocatalysis. Therefore, combining TiO2-film photocatalysis reactor and ultrafiltration can improve organic wastewater quality and increase the permeate flux of ultrafiltration membrane, which may enhance the recycling and reuse of wastewater.

  14. Membrane distillation combined with an anaerobic moving bed biofilm reactor for treating municipal wastewater.

    Science.gov (United States)

    Kim, Hyun-Chul; Shin, Jaewon; Won, Seyeon; Lee, Jung-Yeol; Maeng, Sung Kyu; Song, Kyung Guen

    2015-03-15

    A fermentative strategy with an anaerobic moving bed biofilm reactor (AMBBR) was used for the treatment of domestic wastewater. The feasibility of using a membrane separation technique for post-treatment of anaerobic bio-effluent was evaluated with emphasis on employing a membrane distillation (MD). Three different hydrophobic 0.2 μm membranes made of polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), and polypropylene (PP) were examined in this study. The initial permeate flux of the membranes ranged from 2.5 to 6.3 L m(-2) h(-1) when treating AMBBR effluent at a temperature difference between the feed and permeate streams of 20 °C, with the permeate flux increasing in the order PP membrane gradually decreased to 84% of the initial flux after the 45 h run for distillation, while a flux decline in MD with either the PVDF or PP membrane was not found under the identical distillation conditions. During long-term distillation with the PVDF membrane, total phosphorus was completely rejected and >98% rejection of dissolved organic carbon was also achieved. The characterization of wastewater effluent organic matter (EfOM) using an innovative suite of analytical tools verified that almost all of the EfOM was rejected via the PVDF MD treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Start-up of a free water surface constructed wetland for treating olive mill wastewater

    Directory of Open Access Journals (Sweden)

    Michailides Michail

    2015-01-01

    Full Text Available An olive mill's existing evaporation pond was separated into five cells and transformed into a free water surface constructed wetland. The constructed wetland was used as a post-treatment stage for olive mill wastewater (OMW. Wastewater was previously treated by an aerobic trickling filter. The influent concentrations in the constructed wetland were 27400 mg.L-1, 4800 mg.L-1, 105 mg.L-1 and 770 mg.L-1 for COD, phenols, ortho-phosphate and TKN, respectively. Despite the rather high influent concentrations, the performance of the constructed wetland was very good since after the 60-day start-up operation period it achieved removal rates of about 94%, 95%, 95% and 98% for COD, phenols, ortho-phosphate and TKN, respectively. The major pollutant removal processes can be attributed to both biological processes occurring in the wetland and photo-oxidation. Laboratory-scale experiments with OMW from fifth cell of the wetland revealed that the net contribution of photo-oxidation after 112 hours of simulated solar radiation at 765 W/m2 (i.e. about 38 days of sunlight irradiation was 18% and 31% removal for COD and phenols, respectively. In the constructed wetland, the total removal reached 81% and 86% for COD and phenols, respectively, for the same time period (38 days.

  16. [Characteristic research of shortcut denitrification in synthetic ammonia industrial wastewater treatment process].

    Science.gov (United States)

    Li, Yan; Li, Ze-Bing; Ma, Jia-Xuan; Wang, Xiao-Yi; Zhao, Bai-Hang; Li, Jun

    2012-06-01

    Active sludge was from a pilot-scale synthetic ammonia industrial wastewater treatment plant with a strengthen anoxic-oxic (A/O) technology. The zero order kinetic model was suit for describing shortcut and complete denitrification process. Experimental results showed that shortcut denitrification could reduce 14.1% carbon source consumption and 55.7% denitrification time, respectively, comparing with complete denitrification. The maximum specific denitrification rate was 0.509 g x (g x d)(-1) with an initial NO2(-) -N concentration of 36.82 mg x L(-1) and pH 7.5. In the industrial practice, it must be avoided pH higher than 9.0 in anoxic zone for industrial treatment. Replication-selective denitrifying bacteria showed a strong adaptability to methanol and ethanol, but showed maladaptation to other small molecular and easily biodegradable organics, such as glucose and acetic acid.

  17. Improved ammonium removal from industrial wastewater through systematic adaptation of wild type Chlorella pyrenoidosa.

    Science.gov (United States)

    Ahmed, Asma; Jyothi, Nimmakayala; Ramesh, Adithya

    2017-01-01

    A single step process is proposed for ammonium removal from nitrogenous industrial effluents, with a concomitant generation of algal biomass. A microalgal strain found in the effluent treatment plant of a fertilizer industry in Mumbai, India was systematically adapted to remove up to 700 ppm of ammoniacal nitrogen from industrial wastewater, which is nearly four times higher than the ammonium tolerance reported in the literature as well as other algal strains tested in our laboratory. 18S rRNA sequencing revealed the strain to be Chlorella pyrenoidosa. Effects of process parameters such as pH, temperature and light intensity on cell growth and ammonium removal by the adapted cells were studied. Optimal conditions were found to be pH of 9, temperature of 30 °C and a light intensity of 3,500 Lux for the adapted cells.

  18. Effect of Treated Wastewater Combined with Various Amounts of Manure and Chemical Fertilizers on Nutrient Content and Yield in Corn

    Directory of Open Access Journals (Sweden)

    Abolfazal Tavassoli

    2010-09-01

    Full Text Available In order to study the effects of treated wastewater combined with manure and chemical fertilizers on the nutrients content and forage yield in corn, field experiments were conducted in 2007. The experiments were conducted in a split plot design with three replications. The treatments were comprised of two levels of irrigation water (W1= well water and W2= wastewater in the main plot and five levels of fertilizer (F1= unfertilized, F2 = 100% manure, F3= 50% manure, F4= 100% fertilizer, and F5= 50% fertilizer in the subplot. Results showed that, compared to ordinary water, irrigation with treated wastewater significantly increased fresh and dry forage yield of corn. The treatment using treated wastewater also had a significant effect on N, P, and K contents in corn forage. However, wastewater had no significant effect on plant Fe, Mn, and Zn contents. Among the fertilizer treatments, the highest fresh and dry forage yields and the highest N, P and K contents belonged to the treatments using 100% fertilizer. The highest Fe, Mn, and Zn contents were observed in plants in the treatment with 100% manure.

  19. Governing the reuse of treated wastewater in irrigation : the case study of Jericho, Palestine

    NARCIS (Netherlands)

    Al-Khatib, Nasser; Shoqeir, Jawad A.H.; Özerol, Gül; Majaj, Linda

    2017-01-01

    Wastewater reuse in irrigation provides additional water supply for agriculture and saves freshwater resources for human consumption. Through these benefits, wastewater reuse can significantly alleviate the water scarcity in Palestine and fit to the complexity of the geopolitical context. However,

  20. Anaerobic wastewater treatment in the food processing industry: two case studies

    Energy Technology Data Exchange (ETDEWEB)

    Campos, J.R.; Foresti, E.; Camacho, R.D.P.

    1986-01-01

    This article relates two experiments with wastewater treatment in the food processing industry. One of them refers to the use of an anaerobic filter (meat processing industry) and the other to the use of an upflow anaerobic sludge blanket reactor-UASB (vegetable and fruit processing industry). In the first case, the study describes the performance of an anaerobic filter which has been working for 6 years and provides COD removal efficiency (including primary treatment) equal or better than 80% with an organic loading of 1.4 kg of COD/cubic m/day. The reactor has a bed of broken stones with size of 0.75 m having a medium hydraulic retention time of 13 hours. Discharges of accumulated sludge in a false bottom below the filter are made at intervals of 2 or 3 months. In the second case, the study describes the performance of an upflow anaerobic sludge blanket reactor (88 cubic m) during 255 days of operation including the adaptation phase or startup. This reactor receives wastewater from vegetable and fruit processing including tomato, corn, guava and peach. At the end of each operational phase studied, the COD removal efficiency was about 80%. In the last phase (7.5 hours hydraulic retention time), the organic loading was 1.4 kg of COD/cubic m/day and the hydraulic loading was 3.2 cubic m/cubic m/day. (Refs. 11).

  1. Economic evaluation of alternative wastewater treatment plant options for pulp and paper industry.

    Science.gov (United States)

    Buyukkamaci, Nurdan; Koken, Emre

    2010-11-15

    Excessive water consumption in pulp and paper industry results in high amount of wastewater. Pollutant characteristics of the wastewater vary depending on the processes used in production and the quality of paper produced. However, in general, high organic material and suspended solid contents are considered as major pollutants of pulp and paper industry effluents. The major pollutant characteristics of pulp and paper industry effluents in Turkey were surveyed and means of major pollutant concentrations, which were grouped in three different pollution grades (low, moderate and high strength effluents), and flow rates within 3000 to 10,000m(3)/day range with 1000m(3)/day steps were used as design parameters. Ninety-six treatment plants were designed using twelve flow schemes which were combinations of physical treatment, chemical treatment, aerobic and anaerobic biological processes. Detailed comparative cost analysis which includes investment, operation, maintenance and rehabilitation costs was prepared to determine optimum treatment processes for each pollution grade. The most economic and technically optimal treatment processes were found as extended aeration activated sludge process for low strength effluents, extended aeration activated sludge process or UASB followed by an aeration basin for medium strength effluents, and UASB followed by an aeration basin or UASB followed by the conventional activated sludge process for high strength effluents. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Calcium phosphate precipitation in nitrified wastewater from the potato-processing industry.

    Science.gov (United States)

    Monballiu, A; Ghyselbrecht, K; Crabeels, X; Meesschaert, B

    2018-02-22

    Increasing environmental concerns and the awareness of the finite nature of natural resources make the valorization of waste materials to become a real challenge. The objective of the current research is to investigate the possibility of phosphate recovery as calcium phosphate salts from the wastewater from the potato-processing industry. Batch tests demonstrated that at high pH, struvite and calcium carbonate precipitations are competitive processes and that bicarbonate inhibits the precipitation of calcium phosphate salts. A biological nitrification of the wastewater removed the buffering capacity, the competitive formation of struvite and paved the way for phosphate precipitation as calcium phosphate salts as it also led to the simultaneous removal of (bi)carbonates. It is demonstrated that 75% of the phosphate precipitated as calcium phosphate at a [Ca 2+ ]/[P] ratio of 2.5 at pH 8.5 and as such it provides a convenient alternative for the currently applied struvite processes in the agro-industrial industry.

  3. Modelling of sludge blanket height and flow pattern in UASB reactors treating municipal wastewater

    International Nuclear Information System (INIS)

    Singh, K.S.; Viraraghavan, T.

    2002-01-01

    Two upflow anaerobic sludge blanket (UASB) reactors were started-up and operated for approximately 900 days to examine the feasibility of treating municipal wastewater under low temperature conditions. A modified solid distribution model was formulated by incorporating the variation of biogas production rate with a change in temperature. This model was used to optimize the sludge blanket height of UASB reactors for an effective operation of gas-liquid-solid (GLS) separation device. This model was found to simulate well the solid distribution as confirmed experimental observation of solid profile along the height of the reactor. Mathematical analysis of tracer curves indicated the presence of a mixed type of flow pattern in the sludge-bed zone of the reactor. It was found that the dead-zone and by-pass flow fraction were impacted by the change in operating temperatures. (author)

  4. Performance evaluation of chemical coagulation process to treat bagasse wastewater: modeling and optimization

    Directory of Open Access Journals (Sweden)

    Thirugnanasambandham K.

    2016-03-01

    Full Text Available In this present study, chemical coagulation process (CC treatment process was investigated under different conditions such as pH, ferric chloride dose, agitation time and settling time to treat bagasse wastewater using response surface methodology (RSM. The outcomes were evaluated using Pareto analysis of variance (ANOVA and second order polynomial models were created with the aim of being able to predict the responses. Ideal conditions were observed to be as per the following: agitation time of 25 min, pH of 7, ferric chloride dose of 6 g/L and settling time of 60 min. Under these conditions, turbidity removal of 62%, COD removal of 67%, TDS removal 53% and sludge production of 32 mL/L were obtained with operating cost of 3.50 Rupee/L. The mechanism of CC was analyzed using XRD spectrum and founds to be adsorption.

  5. Ambient temperature SNAD process treating anaerobic digester liquor of swine wastewater.

    Science.gov (United States)

    Daverey, Achlesh; Hung, Nien-Tzu; Dutta, Kasturi; Lin, Jih-Gaw

    2013-08-01

    In present study, effluent from anaerobic digestion of swine wastewater was treated by the simultaneous partial nitrification, anaerobic ammonium oxidation and denitrification (SNAD) process using a lab scale 5L sequencing batch reactor (SBR) under ambient temperature. The fluctuation of anaerobic digester liquor quality (COD, 387 ± 145 mg/L; TKN, 662 ± 190 mg/L; NH₄(+)-N, 519 ± 134 mg/L) and temperature created difficulties to develop a stable SNAD process in the SBR (days 1-285). Fed batch feeding strategy was adopted to have a stable condition in the reactor and overcome the negative effects of organic nitrogen. The average total nitrogen, NH₄(+)-N and COD removal efficiencies in the SBR under steady state conditions (days 485-523) were 80%, 96% and 76%, respectively. The results showed that presence of organic nitrogen, mode of feeding and reactor temperature affects the SNAD process. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Wastewater reuse

    Directory of Open Access Journals (Sweden)

    Milan R. Radosavljević

    2013-12-01

    application and technology applied are ​​significantly dependent on socio-economic circumstances, industry structure, climate and politics. Reuse of water for irrigation of agricultural crops Fourty-one percent of the recycled water in Japan, 60% in California (USA, and 15% in Tunisia is used for irrigation of crops. In China, at least 1.33 million hectares of agricultural land is irrigated with untreated or partially treated wastewater (http://www.eolss.net. Agricultural irrigation is essential to improve the quality and quantity of production. By 2025, agriculture is expected to increase its water requirements by 1.2 times (http://www.unep.or.jp. If wastewater originatines from industrial sources, the presence of toxic chemicals, salts and heavy metals may limit its reuse. Such materials can change soil properties and may affect the growth of crops, so that appropriate treatment and supervision should be practiced. Recycled water that is important for agriculture must contain nitrogen, potassium, zinc, boron and sulfur. However, excess nitrogen can lead to overgrowth, delayed crop maturity and poor quality. Boron is an essential element for plant growth, and the excess boron becomes toxic. Tunisia is one of a few countries that have implemented a national policy for the reuse of wastewater. Since 1960., the wastewater in Tunisia has been used for irrigation of orchards. Since 1989, after a secondary treatment, the wastewater has been used for the cultivation of various crops (olives, fodder, cotton, etc., except for growing vegetables. In countries such as Morocco, Jordan, Egypt, Malta, Cyprus and Spain, wastewater is either used or being considered for irrigation, while in Israel, the percentage of the use of wastewater for irrigation is the highest in the region, with 24.4% and should be increased to 36% in the future (http://www.eolss.net. Depending on the country, socio-economic conditions, may be different,  starting from the shortage of money for capital

  7. Simultaneous Treatment of Agro-Industrial and Industrial Wastewaters: Case Studies of Cr(VI/Second Cheese Whey and Cr(VI/Winery Effluents

    Directory of Open Access Journals (Sweden)

    Triantafyllos I. Tatoulis

    2018-03-01

    Full Text Available Hexavalent chromium (Cr(VI was co-treated either with second cheese whey (SCW or winery effluents (WE using pilot-scale biological trickling filters in series under different operating conditions. Two pilot-scale filters in series using plastic support media were used in each case. The first filter (i.e., Cr-SCW-filter or Cr-WE-filter aimed at Cr(VI reduction and the partial removal of dissolved chemical oxygen demand (d-COD from SCW or WE and was inoculated with indigenous microorganisms originating from industrial sludge. The second filter in series (i.e., SCW-filter or WE-filter aimed at further d-COD removal and was inoculated with indigenous microorganisms that were isolated from SCW or WE. Various Cr(VI (5–100 mg L−1 and SCW or WE (d-COD, 1000–25,000 mg L−1 feed concentrations were tested. Based on the experimental results, the sequencing batch reactor operating mode with recirculation of 0.5 L min−1 proved very efficient since it led to complete Cr(VI reduction in the first filter in series and achieved high Cr(VI reduction rates (up to 36 and 43 mg L−1 d−1, for SCW and WW, respectively. Percentage d-COD removal for SCW and WE in the first filter was rather low, ranging from 14 to 42.5% and from 4 to 29% in the Cr-SCW-filter and Cr-WE-filter, respectively. However, the addition of the second filter in series enhanced total d-COD removal to above 97% and 90.5% for SCW and WE, respectively. The above results indicate that agro-industrial wastewater could be used as a carbon source for Cr(VI reduction, while the use of two trickling filters in series could effectively treat both industrial and agro-industrial wastewaters with very low installation and operational costs.

  8. Demonstration of a full-scale plant using an UASB followed by a ceramic MBR for the reclamation of industrial wastewater.

    Science.gov (United States)

    Niwa, Terutake; Hatamoto, Masashi; Yamashita, Takuya; Noguchi, Hiroshi; Takase, Osamu; Kekre, Kiran A; Ang, Wui Seng; Tao, Guihe; Seah, Harry; Yamaguchi, Takashi

    2016-10-01

    This study comprehensively evaluated the performance of a full-scale plant (4550m(3)d(-1)) using a UASB reactor followed by a ceramic MBR for the reclamation and reuse of mixed industrial wastewater containing many inorganics, chemical, oil and greases. This plant was demonstrated as the first full-scale system to reclaim the mixed industrial wastewater in the world. During 395days of operation, influent chemical oxygen demand (COD) fluctuated widely, but this system achieved COD removal rate of 91% and the ceramic MBR have operated flux of 21-25LMH stably. This means that this system adsorbed the feed water fluctuation and properly treated the water. Energy consumption of this plant was achieved 0.76kWhmm(-3) and this value is same range of domestic sewage MBR system. The combination of an UASB reactor and ceramic MBR is the most economical and feasible solution for water reclamation of mixed industrial wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Removal and transformation of polycyclic aromatic hydrocarbons during electrocoagulation treatment of an industrial wastewater.

    Science.gov (United States)

    Gong, Chenhao; Shen, Gang; Huang, Haiou; He, Peiran; Zhang, Zhongguo; Ma, Baoqing

    2017-02-01

    Polycyclic aromatic hydrocarbons (PAHs) are an important class of water pollutants because of their known ecological and human toxicity. Electrocoagulation (EC) is a promising technology for mitigating industrial wastewater pollution, but the removal and transformation of PAHs during EC treatment has not yet been understood. Therefore, a paper-making wastewater effluent (PMWW) was employed in this study to investigate the relationship between PAHs' removal and transformation during EC treatment. The results show that 86% of PAHs were effectively removed not only by the electro-oxidation reactions, but also by adsorption onto Fe hydroxide flocs. The removal and transformation of PAHs were related to the number of rings in their structures. Some PAHs composed of two aromatic rings (e.g., naphthaline and dimethylnaphthalene) were produced from humic acid-like and fulvic acid-like organics in PMWW, while PAHs with three to four rings were degraded, thus being removed efficiently. Therefore, PAH transformation during EC treatment exerted double-sided effects on the removal of PAHs; the net effect appeared to be positive. Overall, this study revealed the existence and importance of PAH transformation during EC treatment and provided useful guidance for pulp and paper mills to improve the design and operation of wastewater treatment facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Performance evaluation of an side-stream anaerobic membrane bioreactor: Synthetic and alcoholic beverage industry wastewater

    Directory of Open Access Journals (Sweden)

    Nurdan BÜYÜKKAMACI

    2016-06-01

    Full Text Available The treatment performance of a laboratory-scale anaerobic membrane bioreactor (AnMBR using high strength wastewater was evaluated. The AnMBR model system consisted of an up-flow anaerobic sludge blanket reactor (UASB and an ultrafiltration (UF membrane. Its performance was first examined using molasses based synthetic wastewater at different hydraulic retention times (1-3 days and organic loading rates (5-15 kg COD/m3.day. As a result of the experimental studies, maximum treatment efficiency with respect to COD reduction (95% was achieved at 7.5 kg COD/m3.day OLR (CODinfluent=15.000 mg/L, HRT=2 days applications. When OLR was increased to 15 kg COD/m3.day, system performance decreased sharply. Similarly, methane gas production decreased by increasing OLR. After then, feed was changed to real wastewater, which was alcoholic beverage industry effluent. At this study, maximum COD removal efficiency of the system and maximum methane gas production was 88% and 74%, respectively.

  11. PERFORMANCE OF NEWLY CONFIGURED SUBMERGED MEMBRANE BIOREACTOR FOR AEROBIC INDUSTRIAL WASTEWATER TREATMENT

    Directory of Open Access Journals (Sweden)

    I Gede Wenten

    2012-02-01

    Full Text Available The application of membrane to replace secondary clarifier of conventional activated sludge, known as membrane bioreactor, has led to a small footprint size of treatment with excellent effluent quality. The use of MBR eliminates almost all disadvantages encountered in conventional wastewater treatment plant such as low biomass concentration and washout of fine suspended solids. However, fouling remains as a main drawback. To minimize membrane fouling, a new configuration of submerged membrane bioreactor for aerobic industrial wastewater treatment has been developed. For the new configuration, a bed of porous particle is applied to cover the submerged ends-free mounted ultrafiltration membrane. Membrane performance was assessed based on flux productivity and selectivity. By using tapioca wastewater containing high organic matter as feed solution, reasonably high and stable fluxes around 11 l/m2.h were achieved with COD removal efficiency of more than 99%. The fouling analysis also shows that the newly configured ends-free membrane bioreactor exhibits lower irreversible resistance compared with the submerged one. In addition, the performance of pilot scale system, using a membrane module  with 10 m2 effective area and reactor tank with 120 L volume, was also assessed. The flux achieved from the pilot scale system around 8 l/m2.h with COD removal of more than 99%. Hence, this study has demonstrated the feasibility of the newly configured submerged ends-free MBR at larger scale.

  12. Use of adsorption process to remove organic mercury thimerosal from industrial process wastewater.

    Science.gov (United States)

    Velicu, Magdalena; Fu, Hongxiang; Suri, Rominder P S; Woods, Kevin

    2007-09-30

    Carbon adsorption process is tested for removal of high concentration of organic mercury (thimerosal) from industrial process wastewater, in batch and continuously flow through column systems. The organic mercury concentration in the process wastewater is about 1123 mg/L due to the thimerosal compound. Four commercially available adsorbents are tested for mercury removal and they are: Calgon F-400 granular activated carbon (GAC), CB II GAC, Mersorb GAC and an ion-exchange resin Amberlite GT73. The adsorption capacity of each adsorbent is described by the Freundlich isotherm model at pH 3.0, 9.5 and 11.0 in batch isotherm experiments. Acidic pH was favorable for thimerosal adsorption onto the GACs. Columns-in-series experiments are conducted with 30-180 min empty bed contact times (EBCTs). Mercury breakthrough of 30 mg/L occurred after about 47 h (96 Bed Volume Fed (BVF)) of operation, and 97 h (197 BVF) with 120 min EBCT and 180 min EBCT, respectively. Most of the mercury removal is attributed to the 1st adsorbent column. Increase in contact time by additional adsorbent columns did not lower the effluent mercury concentration below 30 mg/L. However, at a lower influent wastewater pH 3, the mercury effluent concentration decreased to less than 7 mg/L for up to 90 h of column operation (183 BVF).

  13. Construction of Microbial-based Biosensor to Measure BOD of Industrial Wastewaters

    Directory of Open Access Journals (Sweden)

    Behnam Mahdavi

    2014-04-01

    Full Text Available In this study a cell-based biosensor for measurement of BOD was designed and developed. Activated sludge collected from wastewater treatment plant of Shahinshahr was used as biological receptor and a Clark cell was used as transducer. According to the results obtained from the sensor calibration, a linear relationship between the current changes and glucose-glutamic acid (GAA standard concentrations up to 50 mg/L was observed. The BOD values of different industrial wastewaters, inlet and outlet of treatment plant of Ardineh Company (Isfahan, and also  inlet and outlet of domestic wastewater treatment plant of Shahinshahr, and outlet of treatment plant of Pegah Company (Isfahan were measured using this biosensor. Comparison of the results of this biosensor and the results of the standard BOD test (BOD5 showed that the mean percentage error measured by the sensor was +29.6%. The results concerning the stability of the designed biosensor showed a stability time of 3 days for the response of biosensor.

  14. Impact of treated wastewater on organismic biosensors at various levels of biological organization

    Energy Technology Data Exchange (ETDEWEB)

    Topić Popović, Natalija, E-mail: ntopic@irb.hr [Laboratory for Ichthyopathology-Biological Materials, Ruđer Bošković Institute, Bijenička 54, Zagreb (Croatia); Strunjak-Perović, Ivančica; Klobučar, Roberta Sauerborn; Barišić, Josip; Babić, Sanja; Jadan, Margita [Laboratory for Ichthyopathology-Biological Materials, Ruđer Bošković Institute, Bijenička 54, Zagreb (Croatia); Kepec, Slavko [Virkom d.o.o, Public Water Supply and Wastewater Services, Kralja Petra Krešimira IV 30, Virovitica. Croatia (Croatia); Kazazić, Snježana P. [Laboratory for Chemical Kinetics and Atmospheric Chemistry, Ruđer Bošković Institute, Bijenička 54, Zagreb (Croatia); Matijatko, Vesna; Beer Ljubić, Blanka [Faculty of Veterinary Medicine, University of Zagreb, Heinzelova 55, Zagreb (Croatia); Car, Ivan [Laboratory for Ichthyopathology-Biological Materials, Ruđer Bošković Institute, Bijenička 54, Zagreb (Croatia); Repec, Siniša; Stipaničev, Draženka [Croatian Waters, Main Water Management Laboratory, Ul. grada Vukovara 220, Zagreb (Croatia); and others

    2015-12-15

    Relating the treated wastewater quality and its impact on organismic biosensors (Prussian carp, Carassius gibelio and earthworm, Eisenia fetida) was the main objective of the study. The impact on health status of fish living downstream, microbiological contamination and antimicrobial resistance, fish tissue structure, blood biochemistry, oxidative stress, genotoxic effects, as well as multixenobiotic resistance mechanism (MXR) was assessed. Treated wastewater discharged from the WWTP modified the environmental parameters and xenobiotic concentrations of the receiving surface waters. Potential bacterial pathogens from fish and respective waters were found in relatively low numbers, although they comprised aeromonads with a zoonotic potential. High resistance profiles were determined towards the tested antimicrobial compounds, mostly sulfamethoxazole and erythromycin. Histopathology primarily revealed gill lamellar fusion and reduction of interlamellar spaces of effluent fish. A significant increase in plasma values of urea, total proteins, albumins and triglycerides and a significant decrease in the activity of plasma superoxide dismutase were noted in carp from the effluent-receiving canal. Micronucleus test did not reveal significant differences between the examined groups, but a higher frequency of erythrocyte nuclear abnormalities was found in fish sampled from the effluent-receiving canal. Earthworms indicated to the presence of MXR inhibitors in water and sludge samples, thus proving as a sensitive sentinel organism for environmental pollutants. The integrative approach of this study could serve as a guiding principle in conducting evaluations of the aquatic habitat health in complex bio-monitoring studies. - Highlights: • Bacteria from fish and water have a zoonotic potential and might pose a health risk • High antimicrobial resistance profiles were determined; particularly to SMX • The sediment total antibiotic concentrations decreased with distance

  15. Impact of treated wastewater on organismic biosensors at various levels of biological organization

    International Nuclear Information System (INIS)

    Topić Popović, Natalija; Strunjak-Perović, Ivančica; Klobučar, Roberta Sauerborn; Barišić, Josip; Babić, Sanja; Jadan, Margita; Kepec, Slavko; Kazazić, Snježana P.; Matijatko, Vesna; Beer Ljubić, Blanka; Car, Ivan; Repec, Siniša; Stipaničev, Draženka

    2015-01-01

    Relating the treated wastewater quality and its impact on organismic biosensors (Prussian carp, Carassius gibelio and earthworm, Eisenia fetida) was the main objective of the study. The impact on health status of fish living downstream, microbiological contamination and antimicrobial resistance, fish tissue structure, blood biochemistry, oxidative stress, genotoxic effects, as well as multixenobiotic resistance mechanism (MXR) was assessed. Treated wastewater discharged from the WWTP modified the environmental parameters and xenobiotic concentrations of the receiving surface waters. Potential bacterial pathogens from fish and respective waters were found in relatively low numbers, although they comprised aeromonads with a zoonotic potential. High resistance profiles were determined towards the tested antimicrobial compounds, mostly sulfamethoxazole and erythromycin. Histopathology primarily revealed gill lamellar fusion and reduction of interlamellar spaces of effluent fish. A significant increase in plasma values of urea, total proteins, albumins and triglycerides and a significant decrease in the activity of plasma superoxide dismutase were noted in carp from the effluent-receiving canal. Micronucleus test did not reveal significant differences between the examined groups, but a higher frequency of erythrocyte nuclear abnormalities was found in fish sampled from the effluent-receiving canal. Earthworms indicated to the presence of MXR inhibitors in water and sludge samples, thus proving as a sensitive sentinel organism for environmental pollutants. The integrative approach of this study could serve as a guiding principle in conducting evaluations of the aquatic habitat health in complex bio-monitoring studies. - Highlights: • Bacteria from fish and water have a zoonotic potential and might pose a health risk • High antimicrobial resistance profiles were determined; particularly to SMX • The sediment total antibiotic concentrations decreased with distance

  16. A comparative analysis of selected wastewater pretreatment processes in food industry

    Science.gov (United States)

    Jaszczyszyn, Katarzyna; Góra, Wojciech; Dymaczewski, Zbysław; Borowiak, Robert

    2018-02-01

    The article presents a comparative analysis of the classical coagulation with the iron sulphate and adsorption on bentonite for the pretreatment of wastewater in the food industry. As a result of the studies, chemical oxygen demand (COD) and total nitrogen (TN) reduction were found to be comparable in both technologies, and a 29% higher total phosphorus removal efficiency by the coagulation was observed. After the coagulation and adsorption processes, a significant difference between mineral and organic fraction in the sludge was found (49% and 51% for bentonite and 28% and 72% for iron sulphate, respectively).

  17. Review of Methods of Wastewater Reuse to Diminish Non-Biodegradable Organic Compounds.

    OpenAIRE

    Bitow Meles, Desbele

    2014-01-01

    Wastewater reuse is very important in water resource management for both environmental and economic reasons. Unfortunately, wastewater from textile industries is difficult to treat by convectional wastewater treatment technologies. Now days, polluted water due to color from textile dyeing and finishing industries is burning issue for researchers. Textile or industrial wastewaters contain non-biodegradable organic compounds, which cannot be easily biodegraded because of their complex chemical ...

  18. Aerobic granular biomass based system integrated with ozonation for efficiently treating wastewater containing refractory compounds (E U Project Life PERBIOF)

    International Nuclear Information System (INIS)

    Di Iaconi, C.; Cavone, L.; Mancini, A.; Molinari, A.; Ramadori, R.

    2009-01-01

    This paper reports the results of an investigation carried out at demonstrative scale aimed at evaluating the performances of an innovative process for treating wastewater containing refractory compounds (i.e., tannery wastewater). In such a process the biological degradation, carried out in a periodic bio filter with granular biomass (SBBGR Sequencing Batch Bio filter Granule Reactor), is integrated with chemical oxidation by ozone used with the aim to render biodegradable the recalcitrant compounds. The obtained results showed high removal efficiencies for COD, total suspended solids, nitrogen and surfactants with residual concentrations in the effluent much lower than Italian limits. Moreover, the process was characterised by very low sludge production (i.e., 0.1 kg of dry sludge/m 3 of treated wastewater) with interesting repercussions on treatment costs (i.e., about 1 euro/m 3 ). [it

  19. Pretreatment of Real Wastewater from the Chocolate Manufacturing Industry through an Integrated Process of Electrocoagulation and Sand Filtration

    OpenAIRE

    García-Morales, Marco A.; Juárez, Julio César González; Martínez-Gallegos, Sonia; Roa-Morales, Gabriela; Peralta, Ever; del Campo López, Eduardo Martin; Barrera-Díaz, Carlos; Miranda, Verónica Martínez; Blancas, Teresa Torres

    2018-01-01

    The purpose of this study was to evaluate the efficiency of removal of suspended solids in terms of turbidity, color, and chemical oxygen demand (COD) when integrating the electrocoagulation process using aluminum sacrificial anodes and the sand filtration process as a pretreatment of wastewater from the chocolate manufacturing plant in Toluca, México. Wastewater from the chocolate manufacturing industry used in this study is classified as nontoxic, but is characterized as having a high conte...

  20. Influence of ozonation and biodegradation on toxicity of industrial textile wastewater.

    Science.gov (United States)

    Paździor, Katarzyna; Wrębiak, Julita; Klepacz-Smółka, Anna; Gmurek, Marta; Bilińska, Lucyna; Kos, Lech; Sójka-Ledakowicz, Jadwiga; Ledakowicz, Stanisław

    2017-06-15

    The textile industry demands huge volumes of high quality water which converts into wastewater contaminated by wide spectrum of chemicals. Estimation of textile wastewater influence on the aquatic systems is a very important issue. Therefore, closing of the water cycle within the factories is a promising method of decreasing its environmental impact as well as operational costs. Taking both reasons into account, the aim of this work was to establish the acute toxicity of the textile wastewater before and after separate chemical, biological as well as combined chemical-biological treatment. For the first time the effects of three different combinations of chemical and biological methods were investigated. The acute toxicity analysis were evaluated using the Microtox ® toxicity test. Ozonation in two reactors of working volume 1 dm 3 (stirred cell) and 20 dm 3 (bubble column) were tested as chemical process, while biodegradation was conducted in two, different systems - Sequence Batch Reactors (SBR; working volume 1.5 dm 3 ) and Horizontal Continuous Flow Bioreactor (HCFB; working volume 12 dm 3 ). The untreated wastewater had the highest toxicity (EC50 value in range: 3-6%). Ozonation caused lower reduction of the toxicity than biodegradation. In the system with SBR the best results were obtained for the biodegradation followed by the ozonation and additional biodegradation - 96% of the toxicity removal. In the second system (with HCFB) two-stage treatment (biodegradation followed by the ozonation) led to the highest toxicity reduction (98%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Thiazolidinone Steroids Impregnated Polyurethane Foams as a Solid Phase Extractant for the Extraction and Preconcentration of Cadmium(II from Industrial Wastewater

    Directory of Open Access Journals (Sweden)

    Mohammad S. Tawfiq Makki

    2011-01-01

    Full Text Available Two new thiazolidinone steroids namely sulfadiazino-imino- steroid (I and 3-sulfonamoyl-phenyl-spiro[4-oxo-thiazolidin-2, 2`steroid] (II were prepared and characterized from their molecular weight determination and spectroscopic measurements. Compound II were physically immobilized onto polyurethane foams (PUFs for the preconcentration of cadmium(II from acidic aqueous media containing iodide ions. The kinetics of the retention step of cadmium(II from aqueous solutions by compound II treated PUFs was studied. Particle diffusion was the most probable operating mechanism and did not control the kinetics of cadmium(II retention by compound II immobilized PUFs. A preconcentration / separation procedure is presented for the solid phase extraction of trace cadmium(II from aqueous media as its ternary complex ion associate with compound II in industrial wastewater samples onto compound II treated PUFs prior to determination by flame atomic absorption spectrometry (FAAS. Compound II treated PUFs sorbent was successfully packed in glass column for complete extraction and / or determination of trace concentrations of cadmium(II in wastewater samples with satisfactory recovery (95±2.6. The cyclic voltammetry of compound II showed two well defined irreversible redox couples and suggested its possible use as complexing agent in stripping voltammetric determination of trace concentrations of toxic metal ions in wastewater.

  2. Isolation and characterization of antibiotic-resistant bacteria from pharmaceutical industrial wastewaters.

    Science.gov (United States)

    Tahrani, Leyla; Soufi, Leila; Mehri, Ines; Najjari, Afef; Hassan, Abdenaceur; Van Loco, Joris; Reyns, Tim; Cherif, Ameur; Ben Mansour, Hedi

    2015-12-01

    Contamination of surface waters in underdeveloped countries is a great concern. Treated and untreated wastewaters have been discharged into rivers and streams, leading to possible waterborne infection outbreaks which may represent a significant dissemination mechanism of antibiotic resistance genes among pathogenic bacterial populations. The present study aims to determine the multi-drug resistance patterns among isolated and identified bacterial strains in a pharmaceutical wastewater effluent in north Tunisia. Fourteen isolates were obtained and seven of them were identified. These isolates belong to different genera namely, Pseudomonas, Acinetobacter, Exiguobacterium, Delftia and Morganella. Susceptibility patterns of these isolates were studied toward commonly used antibiotics in Tunisia. All the identified isolates were found to have 100% susceptibility against colistin sulfate and 100% resistance against amoxicillin. Among the 11 antibiotics tested, six patterns of multi-drug resistance were obtained. The potential of the examined wastewater effluent in spreading multi-drug resistance and the associated public health implications are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A Study on the D. magna and V. fischeri Toxicity Relationship of Industrial Wastewater from Korea

    Science.gov (United States)

    Pyo, S.; Lee, S.; Chun Sang, H.; Park, T. J.; Kim, M. S.

    2015-12-01

    It is well known that high concentration of TDS (total dissolved solid) in industrial effluent gives rise to the toxicity to the Daphnia magna toxicity test. D. magna is vulnerable to relatively low TDS concentration showing the 24-hr EC50 of Salinity 0.6% (as the sea salt concentration). Recently, standard mandatory toxicity testing using Daphnia magna has been used to monitor industrial effluent toxicity according to Korea standard method (Acute Toxicity Test Method of the Daphnia magna Straus (Cladocera, Crustacea), ES 04704. 1a) under regulation. Since only one acute toxicity testing is applied in the present, we are trying to introduce microbial battery for more complete toxicity assessment. In this study, the acute toxicities between daphnids and microbes were compared. The results of D. magna and Vibrio fischeri toxicity test from 165 industrial wastewater effluents showed high positive correlation. In addition, the possibility of predicting daphnia toxicity from the bacterial toxicity data amounts to 92.6% if we consider salinity effect (>5ppt) together. From this study, we found that the V. fischeri toxicity test is a powerful battery tool to assess the industrial wastewater toxicity. Here, we suggest that luminescent bacteria toxicity test be useful not only for complete toxicity assessment which can't be obtained by daphnia toxicity testing only but also for the reduction cost, time, and labor in the Korean society. Keywords : D. magna, V. fischeri, Industrial waste water, battery test Acknowledgement This research was supported by a grant (15IFIP-B089908-02) from Plant Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government

  4. APPLICATION OF MEMBRANES FROM POLYACRYLONITRITE DOPPED WITH GRAPHEN OXIDE IN PURIFICATION OF INDUSTRIAL WASTEWATER GENERATED DURING PROCESSING OF METALS

    Directory of Open Access Journals (Sweden)

    Tomasz Turek

    2017-08-01

    Full Text Available The paper presents results of research on the use of composite membranes of polyacrylonitrile (PAN doped with graphene oxide (GO to remove contaminations of galvanic wastewater. Membranes were obtained using phase inversion method from PAN and GO solution in N,N-dimethylformamide (DMF. Wastewater was pre-treated with the flocculant Magnafloc®336. Next, ultrafiltration of the treated wastewater was carried out in the ultrafiltration cell AMICON on the previously prepared PAN/GO composite membranes. Physico-chemical properties and composition of solutions before and after integrated purification process were analyzed by UV-Vis spectrophotometer and atomic absorption spectrometry (AAS. As a result of flocculation from wastewater there have been removed phosphates (97%, chlorides (5,2%, sulfates (5,9% and iron (82%. In addition, as a result of ultrafiltration was complete removal of phosphate anions (100% and iron (~91-92%, zinc (68÷84%, lead (65-98% and cadmium (~67%.

  5. Ozone and biofiltration as an alternative to reverse osmosis for removing PPCPs and micropollutants from treated wastewater

    DEFF Research Database (Denmark)

    Lee, Carson; Howe, Kerry J.; Thomson, Bruce M.

    2012-01-01

    This pilot-scale research project investigated and compared the removal of pharmaceuticals and personal care products (PPCPs) and other micropollutants from treated wastewater by ozone/biofiltration and reverse osmosis (RO). The reduction in UV254 absorbance as a function of ozone dose correlated...

  6. Enumeração e isolamento de bactérias anaeróbias facultativas num reator de fluxo ascendente e manta de lodo tratando efluente de uma indústria de gelatina - DOI: 10.4025/actascibiolsci.v25i2.1977 Enumeration and isolation of facultative anaerobic bacteria in an upflow anaerobic sludge blanket reactor treating wastewater from a gelatine industry- DOI: 10.4025/actascibiolsci.v25i2.1977

    Directory of Open Access Journals (Sweden)

    Celso Vataru Nakamura

    2003-04-01

    Full Text Available Neste trabalho foram determinados os níveis de bactérias anaeróbias facultativas em Reator de Fluxo Ascendente e Manta de Lodo (UASB utilizado no tratamento de efluente de industria de gelatina. A quantificação dos microrganismos apresentou similar valor na manta de lodo granular e na zona de fluidização. No compartimento de sedimentação do reator as bactérias foram dois logs menores. Estas comunidades são compostas principalmente de bacilos Gram-negativos. Os mais abundantes gêneros foram Acinetobacter, Aeromonas, Citrobacter, Escherichia, Klebsiella e Stenotrophomonas. O significado para a saúde pública das bactérias isoladas no reator UASB é desconhecido. Algumas espécies são residentes permanentes, outras são encontradas em somente uma parte da população, e ainda outras espécies são patógenos oportunistas que causam infecção humana. No presente estudo, nenhuma das bactérias predominantes pertence ao grupo dos patógenos estritosThis experiment measured levels of facultative anaerobic bacteria in an Upflow Anaerobic Sludge Blanket (UASB reactor treating wastewater from a gelatin industry. The microorganism quantification showed similar values in granular sludge bed and fluidized zone. In the settling compartment of reactor, the bacteria were two logs lower. These communities are composed mainly of Gram-negative rods. The most abundant genera isolated were Acinetobacter, Aeromonas, Citrobacter, Escherichia, Klebsiella and Stenotrophomonas. The significance of the bacteria isolated from UASB reactor for public health is unknown. Some species are permanent residents; other are found only in a fraction of the population, and still other species are opportunistic pathogens that cause human infections. In the present study, none of the predominant bacteria belonged to the group of strict pathogens

  7. Contemplating the feasibility of vermiculate blended chitosan for heavy metal removal from simulated industrial wastewater

    Science.gov (United States)

    Prakash, N.; Soundarrajan, M.; Arungalai Vendan, S.; Sudha, P. N.; Renganathan, N. G.

    2017-12-01

    Wastewater contaminated by heavy metals pose great challenges as they are non biodegradable, toxic and carcinogenic to the soil and aquifers. Vermiculite blended with chitosan have been used to remove Cr(VI) and Cd(II) from the industrial wastewater. The results indicate that the vermiculite blended with chitosan adsorb Cr(VI) and Cd(II) from industrial waste water. Batch adsorption experiments were performed as a function of pH 5.0 and 5.5 respectively for chromium and cadmium. The adsorption rate was observed to be 72 and 71 % of chromium and cadmium respectively. The initial optimum contact time for Cr(VI) was 300 min with 59.2 % adsorption and 300 min for Cd(II) with 71.5 % adsorption. Whereas, at 4-6 there is saturation, increasing the solid to liquid ratio for chitosan biopolymers increases the number of active sites available for adsorption. The optimum pH required for maximum adsorption was found to be 5.0 and 5.5 for chromium and cadmium respectively. The experimental equilibrium adsorption data were fitted using Langmuir and Freundlich equations. It was observed that adsorption kinetics of both the metal ions on vermiculite blended chitosan is well be analyzed with pseudo-second-order model. The negative free energy change of adsorption indicates that the process was spontaneous and vermiculite blended chitosan was a favourable adsorbent for both the metals.

  8. Laboratory-scale trials of electrolytic treatment on industrial wastewaters: microbiological aspects.

    Science.gov (United States)

    Zanardini, E; Valle, A; Gigliotti, C; Papagno, G; Ranalli, G; Sorlini, C

    2002-09-01

    Animal, civil and industrial waste matter is a source of potential chemical, microbiological and air pollutants. In populated areas the presence of faecal bacteria and the production of malodorous compounds during waste storage and in the tanks of wastewater treatment plants, can cause concern. The general aim of the work was to study electrolytic waste treatment (recently applied on animal slurry) using low electric current across graphite and copper electrodes, determining its effect on the microflora of sludge, collected from the equalisation basin of an industrial aerobic wastewater treatment plant, and on odour emission abatement. Biochemical and enzymatic indicators like ATP content and a pool of 19 enzymatic activities were tested, comparing them with viable cell counts by traditional microbiological methods, to verify the validity of such indicators in monitoring the electrolytic treatment and to assess their correlation with odour reduction. The preliminary results of our laboratory-scale trials showed that in the presence of inert electrodes, such as graphite, metabolic activity is stimulated, whereas with copper electrodes the ATP content and some enzymatic activities are inhibited quite considerably after only four days, this being accompanied by a marked reduction in odour. Consideration was also given to the total copper released from the electrodes and its recovery using iron electrodes.

  9. Industrial wastewater reuse in petroleum refinery using the WSD for regeneration systems

    Directory of Open Access Journals (Sweden)

    Lídia Yokoyama

    2011-12-01

    Full Text Available Wastewater reuse practices in the industry require an adequate understanding of the characteristics of the manufacture processes, to minimize the water consumption and the generation of effluent. The objective of this work was to apply the WSD method, used to defining the target of minimum process water consumption in a case study of oil refinery, by means of the reuse and recycling operations, including regeneration processes. The importance and influence of the wastewater treatment plant in the regeneration quality, including intermediate process streams, for the reuse and the recycling operations, were evaluated. Furthermore, centralized and distributed treatment flowsheet configurations were tested. Thus, this work presented the solution of a case study with three contaminants in water streams processes, different interconnections approaches, used to illustrate the application of this procedure showing the reduction of water flow rate and total costs compared to the original flowsheet. The scenarios revealed to be greatly promising, and flowsheet configurations were reached with higher than 4 % and 20 % of reduction in the water flow rate consumption and the total costs, respectively. Regarding the ecoefficiency processes, the results demonstrate that the applied technique is successful when the minimum water consumption is the main goal in the industry.

  10. Industrial-scale application of the plunger flow electro-oxidation reactor in wastewater depth treatment.

    Science.gov (United States)

    Huang, Guolong; Yao, Jiachao; Pan, Weilong; Wang, Jiade

    2016-09-01

    Effluents after biochemical treatment contain pollutants that are mostly non-degradable. Based upon previous pilot-scale test results, an industrial-scale electro-oxidation device was built to decompose these refractory materials in the effluent from a park wastewater treatment plant. The electro-oxidation device comprised a ditch-shaped plunger flow electrolysis cell, with mesh-plate Ti/PbO2 electrodes as the anode and the same size mesh-plate Ti as the cathode. Wastewater flowed vertically through electrodes; the effective volume of the cell was 2.8 m(3), and the surface-to-volume ratio was 17.14 m(2) m(-3). The optimal current density was 100 A m(-2), and a suitable flow velocity was 14.0 m h(-1). The removal efficiencies for chemical oxygen demand and color in the effluent were over 60.0 and 84.0 %, respectively. In addition, the electro-oxidation system offered a good disinfection capability. The specific energy consumption for this industrial-scale device was 43.5 kWh kg COD(-1), with a current efficiency of 32.8 %, which was superior to the pilot-scale one. To meet the requirements for emission or reuse, the operation cost was $0.44 per ton of effluent at an average price for electricity of $0.11 kWh(-1).

  11. SYNTHESIS OF MAGNETITE NANOPARTICLES AND EVALUATION OF ITS EFFICIENCY FOR ARSENIC REMOVAL FROM SIMULATED INDUSTRIAL WASTEWATER

    Directory of Open Access Journals (Sweden)

    A. Khodabakhshi

    2011-09-01

    Full Text Available In this study the efficiency of magnetic nanoparticles for removal of trivalent arsenic from synthetic industrial wastewater was evaluated. The nanoparticles was prepared by sol-gel method and characterized by X-ray methods including XRD, XRF, and SEM, and vibrating sample magnetometer (VSM. The results showed that synthesized nanoparticles were in the size range of 40-300 nm, purity of about 90%, and magnetization of nanoparticles was 36.5emu/g. In initial conditions including: pH=7, As(III concentration of 10 mg/L, nanomagnetite concentration of 1g/L, shaking speed of 250 rpm and 20 minute retention time, 82% of As (III was removed. Competition from common coexisting ions such as Na+, Ni2+, Cu2+, SO42-, and Cl- was ignorable but for NO3- was significant. The adsorption data of magnetite nanoparticles fit well with Freundlich isotherm equations. The adsorption capacity of the Fe3O4 for As (III at pH=7 was obtained as 23.8 mg/g. It was concluded that magnetite nanoparticles have considerable potential in removal of As(III from synthetic industrial wastewaters.

  12. Adsorption characteristics of bio-adsorbent on chromium(III) in industrial wastewater.

    Science.gov (United States)

    Lu, Zhufeng; Wang, Hongmei; Li, Jiayou; Yuan, Lixia; Zhu, Lianwen

    2015-01-01

    The removal of chromium(III) (Cr(III)) from industrial wastewater by various low-cost methods has been widely investigated. In this paper, a type of bio-adsorbent was prepared using rice straw modified by fermentation and simple chemical treatment. The aim is to detect the adsorption mechanism and characteristics on Cr(III) ions. The analysis shows that the bio-adsorbent possesses four modified characteristics for Cr(III) adsorption. The first one is the acquired physical adsorption involving concave and convex structures. The second one is the effects of the hydrogen bonding surface hydroxyl groups and the metal chromium ion with complexation. The third one is mainly caused by hydrophilic active groups that possess carboxyl and hydroxyl groups during microbial degradation to combine with ions. The final one is the bio-adsorbent had high adsorption for low concentration of Cr(III) ions. The highest removal of around 97.45% was obtained at pH 5.0, bio-adsorption dosage of 0.5 g L(-1), and initial Cr(III) concentration of 20 mg L(-1). The adsorption process followed the pseudo second-order model (R(2) > 0.99), while the isotherms were fitted to the Freundlich equation (68.1926 mg g(-1)), mainly by chemical adsorption. This study demonstrates the potential of using this biosorbent to remove Cr(III) from both synthetic and industrial wastewater.

  13. Uptake of Heavy Metals from Industrial Wastewater Using In Vitro Plant Cultures.

    Science.gov (United States)

    Jauhari, Nupur; Menon, Sanjay; Sharma, Neelam; Bharadvaja, Navneeta

    2017-11-01

    The plant species Bacopa monnieri has been observed to reduce the heavy metal concentrations in its vicinity. The present study is a comparison of in vitro culture and soil-grown plants of B. monnieri to remove Cr and Cd, from synthetic solution and effluent obtained from industrial area. Results were obtained at every half hour interval upto 180 min. Samples were observed for light absorption using UV-Visible spectrophotometer. Statistically, both systems reclaimed Cr and Cd from polluted water. In vitro cultures showed 67% and 93% removal of Cr and Cd from industrial wastewater whereas soil-grown plants showed 64% and 83% Cr and Cd removal. However, reduction rate was significantly higher for in vitro culture as compared to soil-grown plants. Besides other advantages, in vitro plant cultures proved to be more potent to detoxify pollutants in less time. This approach can be used for the removal of heavy metals at large scale.

  14. Optimizing Hydraulic Retention Times in Denitrifying Woodchip Bioreactors Treating Recirculating Aquaculture System Wastewater.

    Science.gov (United States)

    Lepine, Christine; Christianson, Laura; Sharrer, Kata; Summerfelt, Steven

    2016-05-01

    The performance of wood-based denitrifying bioreactors to treat high-nitrate wastewaters from aquaculture systems has not previously been demonstrated. Four pilot-scale woodchip bioreactors (approximately 1:10 scale) were constructed and operated for 268 d to determine the optimal range of design hydraulic retention times (HRTs) for nitrate removal. The bioreactors were operated under HRTs ranging from 6.6 to 55 h with influent nitrate concentrations generally between 20 and 80 mg NO-N L. These combinations resulted in N removal rates >39 g N m d, which is greater than previously reported. These high removal rates were due in large part to the relatively high chemical oxygen demand and warm temperature (∼19°C) of the wastewater. An optimized design HRT may not be the same based on metrics of N removal rate versus N removal efficiency; longer HRTs demonstrated higher removal efficiencies, and shorter HRTs had higher removal rates. When nitrate influent concentrations were approximately 75 mg NO-N L ( = 6 sample events), the shortest HRT (12 h) had the lowest removal efficiency (45%) but a significantly greater removal rate than the two longest HRTs (42 and 55 h), which were N limited. Sulfate reduction was also observed under highly reduced conditions and was exacerbated under prolonged N-limited environments. Balancing the removal rate and removal efficiency for this water chemistry with a design HRT of approximately 24 h would result in a 65% removal efficiency and removal rates of at least 18 g N m d. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  15. Toward better understanding and feasibility of controlling greenhouse gas emissions from treatment of industrial wastewater with activated sludge.

    Science.gov (United States)

    Chen, Wei-Hsiang; Yang, Jun-Hong; Yuan, Chung-Shin; Yang, Ying-Hsien

    2016-10-01

    Wastewater treatment plants (WWTPs) have been recognized as important sources for anthropogenic greenhouse gas (GHG) emission. The objective of the study was to thoroughly investigate a typical industrial WWTP in southern Taiwan in winter and summer which possesses the emission factors close to those reported values, with the analyses of emission factors, mass fluxes, fugacity, lab-scale in situ experiments, and impact assessment. The activated sludge was the important source in winter and summer, and nitrous oxide (N 2 O) was the main contributor (e.g., 57 to 91 % of total GHG emission in a unit of kg carbon dioxide-equivalent/kg chemical oxygen demand). Albeit important for the GHGs in the atmosphere, the fractional contribution of the GHG emission to the carbon or nitrogen removal in wastewater treatment was negligible (e.g., less than 1.5 %). In comparison with the sludge concentration or retention time, adjusting the aeration rate was more effective to diminish the GHG emission in the activated sludge without significantly affecting the treated water quality. When the aeration rate in the activated sludge simulation was reduced by 75 %, the mass flux of N 2 O could be diminished by up to 53 % (from 9.6 to 4.5 mg/m 2 -day). The total emission in the WWTP (including carbon dioxide, methane, and N 2 O) would decrease by 46 % (from 0.67 to 0.36 kg CO 2 -equiv/kg COD). However, the more important benefit of changing the aeration rate was lowering the energy consumption in operation of the WWTP, as the fractional contribution of pumping to the total emission from the WWTP ranged from 46 to 93 % within the range of the aeration rate tested. Under the circumstance in which reducing the burden of climate change is a global campaign, the findings provide insight regarding the GHG emission from treatment of industrial wastewater and the associated impact on the treatment performance and possible mitigation strategies by operational modifications.

  16. Sterilization of swine wastewater treated by anaerobic reactors using UV photo-reactors

    Directory of Open Access Journals (Sweden)

    Erlon Lopes Pereira

    2014-09-01

    Full Text Available The use of ultraviolet radiation is an established procedure with growing application forthe disinfection of contaminated wastewater. This study aimed to evaluate the efficiency of artificial UV radiation, as a post treatment of liquid from anaerobic reactors treating swine effluent. The UV reactors were employed to sterilize pathogenic microorganisms. To this end, two photo-reactors were constructed using PVC pipe with100 mm diameter and 1060 mmlength, whose ends were sealed with PVC caps. The photo-reactors were designed to act on the liquid surface, as the lamp does not get into contact with the liquid. To increase the efficiency of UV radiation, photo-reactors were coated with aluminum foil. The lamp used in the reactors was germicidal fluorescent, with band wavelength of 230 nm, power of 30 Watts and manufactured by Techlux. In this research, the HRT with the highest removal efficiency was 0.063 days (90.6 minutes, even treating an effluent with veryhigh turbidity due to dissolved solids. It was concluded that the sterilization method using UV has proved to be an effective and appropriate process, among many other procedures.

  17. Evolution of industrial wastewater pollution in the Barcelona Metropolitan Area; Evolucion de la contaminacion industrial en las aguas residuales del area metropolitana de Barcelona

    Energy Technology Data Exchange (ETDEWEB)

    Mantecon Pascual, R.

    2005-07-01

    The Environmental Agency of the Barcelona Metropolitan Area has full powers regarding sewerage. Industrial wastewater emptied into the public sewer system has been monitored and analysed since 1988. the data showing the evolution of the pollution in industrial wastewater are presented, broken down by activities and parameters. These data are based on the analysis of 14,528 samples taken during 19,555 inspections of 5,655 factories. It was found that there has been a gradual improvement in the quality of the effluents. Failure to meet the requirements concerning one or more of the physico-chemical parameters fell from 71% to 39% of the samples analysed. (Author)

  18. An innovative wood-chip-framework soil infiltrator for treating anaerobic digested swine wastewater and analysis of the microbial community.

    Science.gov (United States)

    Zhao, Bowei; Li, Jianzheng; Leu, Shao-Yuan

    2014-12-01

    Combined anaerobic-aerobic processes are efficacious and economic approaches in treating swine wastewater. Nitrogen removal efficiency of these processes, however, is usually limited due to the low carbon/nitrogen (C/N) ratio of the wastewater. An innovative wood-chip-framework soil infiltrator (WFSI) was developed and its performance in treating anaerobic digested swine wastewater was investigated. The WFSI showed comparable removal of chemical oxygen demand (COD) and amongst the highest efficiency of nitrogen removal in treating low C/N wastewater. At a COD volume loading rate of 98.6 g/m3 d the WFSI could remove up to 47.7 g/m3 d of COD. Removal rates of NH4+-N and total nitrogen, also reached 69.1 and 30.4 g/m3 d, respectively, when NH4+-N loading rate was 88.4 g/m3 d. Biological analysis indicated that aerobic, anoxic and anaerobic microbiota occurred throughout the WFSI. Abundant cellulose and lignin decomposing bacteria could degrade the wood chips and provided extra carbon source to enhance denitrification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Toxicity effects of nickel electroplating effluents treated by photoelectrooxidation in the industries of the Sinos River Basin

    Directory of Open Access Journals (Sweden)

    T Benvenuti

    Full Text Available The Sinos river Basin is an industrial region with many tanneries and electroplating plants in southern Brazil. The wastewater generated by electroplating contains high loads of salts and metals that have to be treated before discharge. After conventional treatment, this study applied an advanced oxidative process to degrade organic additives in the electroplating bright nickel baths effluent. Synthetic rinsing water was submitted to physical-chemical coagulation for nickel removal. The sample was submitted to ecotoxicity tests, and the effluent was treated by photoelectrooxidation (PEO. The effects of current density and treatment time were evaluated. The concentration of total organic carbon (TOC was 38% lower. The toxicity tests of the effluent treated using PEO revealed that the organic additives were partially degraded and the concentration that is toxic for test organisms was reduced.

  20. Reuse of Treated Internal or External Wastewaters in the Cooling Systems of Coal-Based Thermoelectric Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Radisav Vidic; David Dzombak; Ming-Kai Hsieh; Heng Li; Shih-Hsiang Chien; Yinghua Feng; Indranil Chowdhury; Jason Monnell

    2009-06-30

    This study evaluated the feasibility of using three impaired waters - secondary treated municipal wastewater, passively treated abandoned mine drainage (AMD), and effluent from ash sedimentation ponds at power plants - for use as makeup water in recirculating cooling water systems at thermoelectric power plants. The evaluation included assessment of water availability based on proximity and relevant regulations as well as feasibility of managing cooling water quality with traditional chemical management schemes. Options for chemical treatment to prevent corrosion, scaling, and biofouling were identified through review of current practices, and were tested at bench and pilot-scale. Secondary treated wastewater is the most widely available impaired water that can serve as a reliable source of cooling water makeup. There are no federal regulations specifically related to impaired water reuse but a number of states have introduced regulations with primary focus on water aerosol 'drift' emitted from cooling towers, which has the potential to contain elevated concentrations of chemicals and microorganisms and may pose health risk to the public. It was determined that corrosion, scaling, and biofouling can be controlled adequately in cooling systems using secondary treated municipal wastewater at 4-6 cycles of concentration. The high concentration of dissolved solids in treated AMD rendered difficulties in scaling inhibition and requires more comprehensive pretreatment and scaling controls. Addition of appropriate chemicals can adequately control corrosion, scaling and biological growth in ash transport water, which typically has the best water quality among the three waters evaluated in this study. The high TDS in the blowdown from pilot-scale testing units with both passively treated mine drainage and secondary treated municipal wastewater and the high sulfate concentration in the mine drainage blowdown water were identified as the main challenges for blowdown

  1. Application of toxicity identification evaluation procedures on wastewaters and sludge from a municipal sewage treatment works with industrial inputs.

    Science.gov (United States)

    Hongxia, Yu; Jing, Cheng; Yuxia, Cui; Huihua, Shang; Zhonghai, Ding; Hongjun, Jin

    2004-03-01

    A comparison of influent and effluent wastewater toxicities to Daphnia magna was undertaken to determine the most representative aqueous fraction for future toxicity identification evaluation (TIE) studies. Wastewater samples originated from a wastewater treatment plant which receives mainly domestic wastewater and industrial effluents. The TIE results reveal that the key toxicant contained in the influent was 2-propylbezaldehyde oxime. Results suggest that greater attention needs to be given to the receiving influent containing 2-propylbezaldehyde oxime to avoid damaging the bacterial populations in the primary activated sludge process. In addition, in order to evaluate the applicability of the reuse of activated sludge as a fertilizer in agriculture, TIE studies were also performed on water extracts from surplus sludge.

  2. Do Contaminants Originating from State-of-the-Art Treated Wastewater Impact the Ecological Quality of Surface Waters?

    Science.gov (United States)

    Stalter, Daniel; Magdeburg, Axel; Quednow, Kristin; Botzat, Alexandra; Oehlmann, Jörg

    2013-01-01

    Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0–100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn), 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide) as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in urban areas this

  3. The effect of rhamnolipid biosurfactant produced by Pseudomonas fluorescens on model bacterial strains and isolates from industrial wastewater.

    Science.gov (United States)

    Vasileva-Tonkova, Evgenia; Sotirova, Anna; Galabova, Danka

    2011-02-01

    In this study, the effect of rhamnolipid biosurfactant produced by Pseudomonas fluorescens on bacterial strains, laboratory strains, and isolates from industrial wastewater was investigated. It was shown that biosurfactant, depending on the concentration, has a neutral or detrimental effect on the growth and protein release of model Gram (+) strain Bacillus subtilis 168. The growth and protein release of model Gram (-) strain Pseudomonas aeruginosa 1390 was not influenced by the presence of biosurfactant in the medium. Rhamnolipid biosurfactant at the used concentrations supported the growth of some slow growing on hexadecane bacterial isolates, members of the microbial community. Changes in cell surface hydrophobicity and permeability of some Gram (+) and Gram (-) isolates in the presence of rhamnolipid biosurfactant were followed in experiments in vitro. It was found that bacterial cells treated with biosurfactant became more or less hydrophobic than untreated cells depending on individual characteristics and abilities of the strains. For all treated strains, an increase in the amount of released protein was observed with increasing the amount of biosurfactant, probably due to increased cell permeability as a result of changes in the organization of cell surface structures. The results obtained could contribute to clarify the relationships between members of the microbial community as well as suggest the efficiency of surface properties of rhamnolipid biosurfactant from Pseudomonas fluorescens making it potentially applicable in bioremediation of hydrocarbon-polluted environments.

  4. Pretreatment of furfural industrial wastewater by Fenton, electro-Fenton and Fe(II)-activated peroxydisulfate processes: a comparative study.

    Science.gov (United States)

    Yang, C W; Wang, D; Tang, Q

    2014-01-01

    The Fenton, electro-Fenton and Fe(II)-activated peroxydisulfate (PDS) processes have been applied for the treatment of actual furfural industrial wastewater in this paper. Through the comparative study of the three processes, a suitable pretreatment technology for actual furfural wastewater treatment was obtained, and the mechanism and dynamics process of this technology is discussed. The experimental results show that Fenton technology has a good and stable effect without adjusting pH of furfural wastewater. At optimal conditions, which were 40 mmol/L H₂O₂ initial concentration and 10 mmol/L Fe²⁺ initial concentration, the chemical oxygen demand (COD) removal rate can reach 81.2% after 90 min reaction at 80 °C temperature. The PDS process also has a good performance. The COD removal rate could attain 80.3% when Na₂S₂O₈ initial concentration was 4.2 mmol/L, Fe²⁺ initial concentration was 0.1 mol/L, the temperature remained at 70 °C, and pH value remained at 2.0. The electro-Fenton process was not competent to deal with the high-temperature furfural industrial wastewater and only 10.2% COD was degraded at 80 °C temperature in the optimal conditions (2.25 mA/cm² current density, 4 mg/L Na₂SO₄, 0.3 m³/h aeration rate). For the Fenton, electro-Fenton and PDS processes in pretreatment of furfural wastewater, their kinetic processes follow the pseudo first order kinetics law. The pretreatment pathways of furfural wastewater degradation are also investigated in this study. The results show that furfural and furan formic acid in furfural wastewater were preferentially degraded by Fenton technology. Furfural can be degraded into low-toxicity or nontoxic compounds by Fenton pretreatment technology, which could make furfural wastewater harmless and even reusable.

  5. The challenges of treating high strength wastewaters: CWAO using MWNT supported ruthenium catalysts

    Energy Technology Data Exchange (ETDEWEB)

    GarcIa, J.; Gomes, H.T.; Figueiredo, J.L.; Faria, J.L. [Porto Univ., Lab. de Catalise e Materiais, Dept. de Engenharia Quimica, Faculdade de Engenharia (Portugal); Garcia, J. [Madrid Univ. Complutense, Grupo de Catalisis y Operaciones de Separacion, Dept. de Ingenieria Quimica, Facultad de Ciencias (Spain); Serp, P.; Kalck, P. [Ecole Nationale Superieure des Ingenieurs en Arts Chimiques et Technologiques, Lab. de Catalyse, Chimie Fine et Polymeres, 31 - Toulouse (France)

    2005-07-01

    High strength wastewaters containing aromatic compounds are normally not efficiently treated by conventional methods, including the common biological treatment. In these cases a more sophisticated approach is necessary to attain the desired levels of purification. Catalytic wet air oxidation (CWAO) using carbon based catalysts is employed worldwide as effective pre-treatment of effluents with these characteristics. Carbon materials are preferred as active catalysts or support for preparing them due to their morphological and structural characteristics. In the last 10 years, due to a tremendous development in materials production and processing, carbon nano-structures are becoming more accessible and common widening their range of applications [1]. In this context, the scope of the present work is to illustrate a potential use of multi-walled carbon nano-tubes (MWNT) supported ruthenium catalysts for catalytic wet air oxidation of aniline polluted wastewaters. The metal was supported by incipient wetness and excess impregnation, starting from liquid solutions of three different Ru precursors. Impregnation was carried out on modified MWNT, namely on MWNT-COOH (HNO{sub 3} modified) and MWNT-COONa (HNO{sub 3}/Na{sub 2}CO{sub 3} modified). For the 1% weight Ru/MWNT catalysts, the order of activities decreased in the sequence Ru(COD)(COT){>=}RuCl{sub 3}{>=}Ru(C{sub 5}H{sub 5}){sub 2}. The conversion of aniline after 45 min of reaction was 100% for the catalyst prepared with Ru(COD)(COT). The influence of the Ru precursor, preparation method and the support surface modification was studied comparing the conversion of aniline obtained for the different prepared Ru/MWNT catalysts (Figure 1). MWNT as support material, provide a significant metal dispersion with very small Ru nanoparticles (Figure 2) being observed. This will induce an efficient surface contact between the aniline molecule and the active sites [2]. The excellent catalytic performances of Ru/MWNT are explained

  6. Production of chlorothalonil hydrolytic dehalogenase from agro-industrial wastewater and its application in raw food cleaning.

    Science.gov (United States)

    He, Qin; Xu, Xi-Hui; Zhang, Fan; Tai, Yu-Kai; Luo, Yan-Fei; He, Jian; Hong, Qing; Jiang, Jian-Dong; Yan, Xin

    2017-06-01

    To reduce the fermentation cost for industrialization of chlorothalonil hydrolytic dehalogenase (Chd), agro-industrial wastewaters including molasses, corn steep liquor (CSL) and fermentation wastewater were used to substitute for expensive carbon and nitrogen sources and fresh water for lab preparation. The results showed that molasses and CSL could replace 5% carbon source and 100% organic nitrogen source respectively to maintain the same fermentation level. Re-fermentation from raffinate of ultra-filtered fermentation wastewater could achieve 61.03% of initial Chd activity and reach 96.39% activity when cultured in a mixture of raffinate and 50% of original medium constituent. Typical raw foods were chosen to evaluate the chlorothalonil removal ability of Chd. After Chd treatment for 2 h at room temperature, 97.40 and 75.55% of 30 mg kg -1 chlorothalonil on cherry tomato and strawberry respectively and 60.29% of 50 mg kg -1 chlorothalonil on Chinese cabbage were removed. Furthermore, the residual activity of the enzyme remained at 78-82% after treatment, suggesting its potential for reuse. This study proved the cost-feasibility of large-scale production of Chd from agro-industrial wastewater and demonstrated the potential of Chd in raw food cleaning. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  7. Aerated lagooning of agro-industrial wastewater: depuration performance and energy requirements

    Directory of Open Access Journals (Sweden)

    Serafina Andiloro

    2013-09-01

    Full Text Available Intensive depuration plants have often shown low reliability and economic sustainability, when utilised for agro-industrial wastewater treatment, due to the particular wastewater properties: high organic load and essential oil concentrations, acidity, nutrient scarcity and qualitative-quantitative variability of effluents. Aerated lagooning systems represent a suitable alternative, because they are able to assure good reliability and low energy requirements, avoiding the drawbacks shown by the intensive depuration plants. In order to optimize performance of the lagooning systems, particularly in terms of energy requirements, depuration processes of aerobic-anaerobic aerated lagoons were investigated, both at full- and laboratory-scale. Citrus processing wastewater were subject to bubble aeration with low flow rates and limited time; the removal rate of organic load was evaluated and energy requirements of different depuration schemes were compared. The experimental investigations in full-scale aerated lagoons showed a low energy supply (0.21-0.59 kWh per kg of COD (Chemical Oxygen Demand removed with an average value of 0.45 kWh kgCOD –1, an adequate equalisation capability and constantly good depurative performance also with high concentrations of essential oil (500-1000 ppm. The experimental investigations in lab-scale aerated tanks under controlled conditions indicated the possibility of decreasing energy requirements (down to 0.16 kWh kgCOD –1 by reducing aeration power (down to 0.6 W m–3 and limiting aeration time to night 12 hours only, when energy price is lower. In spite of the low aeration, the COD removal rates were on the average six-fold higher compared to the anaerobic tank. Other outcomes indicated an ability of the spontaneous microflora to adapt to high concentrations of essential oils, which however did not provide an increase of the removal rate of the organic load in the experimented scheme.

  8. Chlorine Disinfection of Blended Municipal Wastewater Effluents

    Science.gov (United States)

    Blending is a practice used in the wastewater industry to manage wet weather events when the influx of storm water to municipal treatment facilities could compromise the hydraulic capacity of the facility’s biological treatment system. To prevent this, wastewater is treated thro...

  9. Performance study of biofilter developed to treat H2S from wastewater odour.

    Science.gov (United States)

    Omri, Ilhem; Aouidi, Fethia; Bouallagui, Hassib; Godon, Jean-Jacques; Hamdi, Moktar

    2013-04-01

    Biofiltration is an efficient biotechnological process used for waste gas abatement in various industrial processes. It offers low operating and capital costs and produces minimal secondary waste streams. The objective of this study was to evaluate the performance of a pilot scale biofilter in terms of pollutants' removal efficiencies and the bacterial dynamics under different inlet concentrations of H2S. The treatment of odourous pollutants by biofiltration was investigated at a municipal wastewater treatment plant (WWTP) (Charguia, Tunis, Tunisia). Sampling and analyses were conducted for 150 days. Inlet H2S concentration recorded was between 200 and 1300 mg H2S.m(-3). Removal efficiencies reached 99% for the majority of the running time at an empty bed retention time (EBRT) of 60 s. Heterotrophic bacteria were found to be the dominant microorganisms in the biofilter. The bacteria were identified as the members of the genus Bacillus, Pseudomonas and xanthomonadacea bacterium. The polymerase chain reaction-single stranded conformation polymorphism (PCR-SSCP) method showed that bacterial community profiles changed with the H2S inlet concentration. Our results indicated that the biofilter system, containing peat as the packing material, was proved able to remove H2S from the WWTP odourous pollutants.

  10. Long-term evaluation of a sequential batch reactor (SBR) treating dairy wastewater for carbon removal.

    Science.gov (United States)

    Gutiérrez, Soledad; Ferrari, Adrián; Benítez, Alejandra; Travers, Dayana; Menes, Javier; Etchebehere, Claudia; Canetti, Rafael

    2007-01-01

    Many dairy industries have been using SBR wastewater treatment plants because they allow optimal working condition to be reached. However, to take advantage of SBR capabilities, strong process automation is needed. The aim of this work is to study the factors that influence SBR performance to improve modelling and control. To better understand the whole process we studied the kinetic modelling, the carbon removal mechanism and the relation between reactor performance, aerobic heterotrophic activity and bacterial population dynamics (by terminal restriction fragment length polymorphisms of 16S rDNA, T-RFLP). The heterotrophic activity values presented high variability during some periods; however, this was not reflected on the reactor performance. As sludge health indicator, the average activity in a period was better than individual values. Although all the carbon removal mechanisms are still unclear for this process, they seemed to be influenced by non-respirometric ways (storage, biosorption, accumulation, etc.). The variability of heterotrophic activity could be correlated with the bacterial population diversity over time. Despite the high variability of the activity, a simple kinetic model (pseudo ASM1) based on apparent constant parameters was developed and calibrated. Such modellisation provided a good tool for control purposes.

  11. Possible applications of ferrate(VI in the treatment of industrial wastewater effluent in the laboratory

    Directory of Open Access Journals (Sweden)

    Nikolić-Bujanović Ljiljana N.

    2015-01-01

    Full Text Available This paper shows the effects of ferrate(VI application in the treatment of industrial wastewater effluent in laboratory conditions. Samples used are a mixture of wastewater effluent from various industrial plants whose composition was determined by analyzing samples before the ferrate(VI treatment. Determining physical-chemical characteristics of the samples showed very high chemical oxygen demand (COD and the concentrations of individual pollutants are higher than the maximum allowed. In the tested samples, the COD was from 18 (sample 1 to 580 times (sample 2 greater than allowed (allowed 45 - 150 mg/l, while the concentrations of certain metals were several times higher than allowed (Cu allowed 0,1 mg/l, Zn allowed 0,2 mg/l. Also, a high concentration of total phosphorus content (allowed 2 mg/l and fluoride was found (allowed 20 mg/l, 2-3 times higher than permissible. The applied Na2FeO4 was synthesized by electrochemical method and applied in situ. Physical-chemical testing of samples, after treatment with different amounts (2, 5, 8, and 10 ml of Na2FeO4, concentration of 8 g/l showed that ferrate(VI can be used as a multifunctional agent in the purification of industrial wastewater, where in the amount of contaminating matter is reduced below the maximum permitted level. It was demonstrated the high efficiency of ferrate(VI as a strong oxidant in the removal of total P and suspended materials. Also pointed out was the high sorption power of the generated ferric(IIIhydroxide, which with its developed surface absorbs 95,5% of the F- and removes it from the solution in the form of sludge. Showed a high efficiency of ferrate(VI in the total removal of P (70 to 99,5%, and F- (89 to 95,5%, but depending on the presence of the total COD value or the presence of the total organic substances. At high values of the COD major part of ferrate(VI is consumed in the oxidation of organic material and the formation of Fe(OH3, which accelerate the process

  12. Strategy to identify the causes and to solve a sludge granulation problem in methanogenic reactors: application to a full-scale plant treating cheese wastewater.

    Science.gov (United States)

    Macarie, Hervé; Esquivel, Maricela; Laguna, Acela; Baron, Olivier; El Mamouni, Rachid; Guiot, Serge R; Monroy, Oscar

    2017-08-26

    Granulation of biomass is at the basis of the operation of the most successful anaerobic systems (UASB, EGSB and IC reactors) applied worldwide for wastewater treatment. Despite of decades of studies of the biomass granulation process, it is still not fully understood and controlled. "Degranulation/lack of granulation" is a problem that occurs sometimes in anaerobic systems resulting often in heavy loss of biomass and poor treatment efficiencies or even complete reactor failure. Such a problem occurred in Mexico in two full-scale UASB reactors treating cheese wastewater. A close follow-up of the plant was performed to try to identify the factors responsible for the phenomenon. Basically, the list of possible causes to a granulation problem that were investigated can be classified amongst nutritional, i.e. related to wastewater composition (e.g. deficiency or excess of macronutrients or micronutrients, too high COD proportion due to proteins or volatile fatty acids, high ammonium, sulphate or fat concentrations), operational (excessive loading rate, sub- or over-optimal water upflow velocity) and structural (poor hydraulic design of the plant). Despite of an intensive search, the causes of the granulation problems could not be identified. The present case remains however an example of the strategy that must be followed to identify these causes and could be used as a guide for plant operators or consultants who are confronted with a similar situation independently of the type of wastewater. According to a large literature based on successful experiments at lab scale, an attempt to artificially granulate the industrial reactor biomass through the dosage of a cationic polymer was also tested but equally failed. Instead of promoting granulation, the dosage caused a heavy sludge flotation. This shows that the scaling of such a procedure from lab to real scale cannot be advised right away unless its operability at such a scale can be demonstrated.

  13. Bioremediation and Detoxification of Synthetic Wastewater Containing Triarylmethane Dyes by Aeromonas hydrophila Isolated from Industrial Effluent

    Directory of Open Access Journals (Sweden)

    Chimezie Jason Ogugbue

    2011-01-01

    Full Text Available Economical and bio-friendly approaches are needed to remediate dye-contaminated wastewater from various industries. In this study, a novel bacterial strain capable of decolorizing triarylmethane dyes was isolated from a textile wastewater treatment plant in Greece. The bacterial isolate was identified as Aeromonas hydrophila and was shown to decolorize three triarylmethane dyes tested within 24 h with color removal in the range of 72% to 96%. Decolorization efficiency of the bacterium was a function of operational parameters (aeration, dye concentration, temperature, and pH and the optimal operational conditions obtained for decolorization of the dyes were: pH 7-8, 35∘C and culture agitation. Effective color removal within 24 h was obtained at a maximum dye concentration of 50 mg/L. Dye decolorization was monitored using a scanning UV/visible spectrophotometer which indicated that decolorization was due to the degradation of dyes into non-colored intermediates. Phytotoxicity studies carried out using Triticum aestivum, Hordeum vulgare, and Lens esculenta revealed the triarylmethane dyes exerted toxic effects on plant growth parameters monitored. However, significant reduction in toxicity was obtained with the decolorized dye metabolites thus, indicating the detoxification of the dyes following degradation by Aeromonas hydrophila.

  14. EVALUATION OF INDUSTRIAL DYEING WASTEWATER TREATMENT WITH COAGULANTS AND POLYELECTROLYTE AS A COAGULANT AID

    Directory of Open Access Journals (Sweden)

    G. R. Nabi Bidhendi;A. Torabian;H. Ehsani;N. Razmkhah

    2007-01-01

    Full Text Available Textile industry is the major source of water consumption and wastewater pollution. There are various treatment techniques to remove textile wastewater pollution. Coagulation-flocculation is a widely used process to remove pollution due to suspended particles. In this research, different coagulants like Alum, Lime, FeCl3, FeSO4 and MgCl2 were applied to select the suitable ones with optimum removal efficiency. Settling characteristics of flocs formed in the coagulation process were studied in a laboratory scale settling column unit. Parameters such as color, COD, TSS, turbidity and settled sludge volume have been evaluated. The optimum coagulant dose and pH value were determined by comparing the effectiveness of these coagulants. Results showed other coagulants except lime could eliminate color and COD successfully. In this case, FeSO4 was chosen as an optimum coagulant for color removal because of the lowest required coagulant dose, minimum settled sludge volume and maximum decolorization.

  15. Waste biomass adsorbents for copper removal from industrial wastewater--a review.