WorldWideScience

Sample records for transverse optical diagnostics

  1. Noninterceptive transverse beam diagnostics

    International Nuclear Information System (INIS)

    Chamberlin, D.D.; Minerbo, G.N.; Teel, L.E. Jr.; Gilpatrick, J.D.

    1981-01-01

    The transverse emittance properties of a high-current linear accelerator may be measured by using TV cameras sensitive to the visible radiation emitted following beam interactions with residual gas. This paper describes the TV system being used to measure emittances for the Fusion Materials Irradiation Test (FMIT) project

  2. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  3. Transverse electron beam diagnostics at REGAE

    Energy Technology Data Exchange (ETDEWEB)

    Bayesteh, Shima

    2014-12-15

    The use of high-intensity electron and X-ray pulsed sources allows for the direct observation of atomic motions as they occur. While the production of such high coherent, brilliant, short X-ray pulses requires large-scale and costly accelerator facilities, it is feasible to employ a high-intensity source of electrons by exploiting a more compact design. The Relativistic Electron Gun for Atomic Exploration (REGAE) facility is a small linear accelerator at DESY, Hamburg, equipped with a photocathode radio frequency (RF) gun that produces relativistic ultra-short (<100 fs), low charge (<1 pC) electron bunches of high coherence. By means of time-resolved diffraction experiments, such an electron source can probe ultrafast laser-induced atomic structural changes that occur with a temporal resolution of ∝100 fs. A comprehensive characterization of the electron beam, for every pulse, is of fundamental importance to study the atomic motions with the desired resolution and quality. This thesis reports on the transversal diagnostics of the electron beam with an emphasis on a scintillator-based beam profile monitor. The diagnostics is capable of evaluating the beam parameters such as charge, energy, energy spread and transverse profile, at very low charges and on a shot-to-shot basis. A full characterization of the scintillator's emission, the optical setup and the detector (camera) of the profile monitor is presented, from which an absolute charge calibration of the system is derived. The profile monitor is specially developed to accommodate more applications, such as dark current suppression, overlapping the electron probe and the laser pump within 1 ns accuracy, as well as charge and transverse emittance measurements. For the determination of the transverse emittance two techniques were applied. The first one introduces a new method that exploits a diffraction pattern to measure the emittance, while the second one is based on a version of the Pepper-pot technique. A

  4. Transverse electron beam diagnostics at REGAE

    International Nuclear Information System (INIS)

    Bayesteh, Shima

    2014-12-01

    The use of high-intensity electron and X-ray pulsed sources allows for the direct observation of atomic motions as they occur. While the production of such high coherent, brilliant, short X-ray pulses requires large-scale and costly accelerator facilities, it is feasible to employ a high-intensity source of electrons by exploiting a more compact design. The Relativistic Electron Gun for Atomic Exploration (REGAE) facility is a small linear accelerator at DESY, Hamburg, equipped with a photocathode radio frequency (RF) gun that produces relativistic ultra-short (<100 fs), low charge (<1 pC) electron bunches of high coherence. By means of time-resolved diffraction experiments, such an electron source can probe ultrafast laser-induced atomic structural changes that occur with a temporal resolution of ∝100 fs. A comprehensive characterization of the electron beam, for every pulse, is of fundamental importance to study the atomic motions with the desired resolution and quality. This thesis reports on the transversal diagnostics of the electron beam with an emphasis on a scintillator-based beam profile monitor. The diagnostics is capable of evaluating the beam parameters such as charge, energy, energy spread and transverse profile, at very low charges and on a shot-to-shot basis. A full characterization of the scintillator's emission, the optical setup and the detector (camera) of the profile monitor is presented, from which an absolute charge calibration of the system is derived. The profile monitor is specially developed to accommodate more applications, such as dark current suppression, overlapping the electron probe and the laser pump within 1 ns accuracy, as well as charge and transverse emittance measurements. For the determination of the transverse emittance two techniques were applied. The first one introduces a new method that exploits a diffraction pattern to measure the emittance, while the second one is based on a version of the Pepper-pot technique. A

  5. Simulation study of transverse optical klystron radiation

    International Nuclear Information System (INIS)

    Xu Hongliang; Diao Caozheng; Liu Jinying; He Duohui; Jia Qika; Wang Xiangqi

    1997-01-01

    The radiation from a transverse optical klystron (TOK) is calculated by far field approximation equation and numerical integration, in which the effects of electron-beam emittance and energy spread are considered. Accurate electron-beam profiles have been experimentally determined and modeled by the Monte Carlo method. The calculated spectra illustrate the emittance of Hefei storage ring imposes on the spontaneous radiation of TOK

  6. FEL in transverse optical klystron regime

    International Nuclear Information System (INIS)

    Scarlat, F.; Baltateanu, N.

    1994-01-01

    Among all operational regimes of free electron laser (FEL), the transverse optical regime (TOK) requires the least stringent electron beam parameters. The device associated to this regime, also defined as FEL with two or more components, consists of two or more identical interaction sections separated by one or more drift distances among themselves. Starting from the motion equations which describe the interaction between an electron and the radiation inside the undulator, one can obtain some practical expressions for the calculation of the efficiency of the energy transfer from the electron to the radiation, and the gain of the external coherent radiation for a FEL in TOK with three cavities. (Author)

  7. Progress In Transverse Feedbacks and Related Diagnostics for Hadron Machines

    CERN Document Server

    Hofle, W

    2013-01-01

    Today Hadron Accelerators with high intensity and high brightness beams increasingly rely on transverse feedback systems for the control of instabilities and the preservation of the transverse emittance. With particular emphasis, but not limited to, the CERN Hadron Accelerator Chain, the progress made in recent years, and the performances achieved are reviewed. Hadron colliders such as the LHC represent a particular challenge as they ask for low noise electronic systems in these feedbacks for acceptable emittance growth. Achievements of the LHC transverse feedback system used for damping injection oscillations and to provide stability throughout the cycle are summarized. This includes its use for abort gap and injection cleaning as well as transverse blow-up for diagnostics purposes. Beyond systems already in operation, advances in technology and modern digital signal processing with increasingly higher digitization rates have made systems conceivable to cure intra-bunch motion. With its capabilities to both ...

  8. Optical beam diagnostics on PEP

    International Nuclear Information System (INIS)

    Sabersky, A.P.

    1981-02-01

    In designing the PEP optical diagnostics we have been able to build on the experience gained with SPEAR. Most of the problems at SPEAR could be traced to the optical diagnostic system being inside the tunnel. A machine shutdown is required for any maintenance or modification. This implies that in order to make such an instrument successful, a large engineering effort must be mounted to ensure 100% operation at startup. The functions that do not work at startup may never be made to work; this has happened at several machines. Experimental setups are likewise risky and time consuming. A point which has been borne out in both SPEAR and PEP is that the mechanical part of the instrument, the special vacuum chamber, the optical mounts, the alignment and adjustments, require approximately 60% of the effort and cost of the optical diagnostics. It is far better to economize on detectors and electronics than on mechanical and optical essentials

  9. Optical diagnostics of intermittent flows

    DEFF Research Database (Denmark)

    Okulov, V.L.; Naumov, I.V.; Sørensen, Jens Nørkær

    2007-01-01

    The efficiency of combined use of different optical techniques for flow diagnostics is demonstrated with the practically important case of intense swirling flows. It is shown that, when applied separately, commonly used optical measuring techniques, such as laser Doppler anemometry and particle...... is for the first time applied for diagnostics of the flow pattern in a closed cylinder with a rotating end face with the aim of studying the changeover from the steady axisymmetric to unsteady asymmetric flow over a wide range of flow parameters. It is found that such a transition is notable for azimuthal...

  10. A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer.

    Science.gov (United States)

    Zuanetti, Bryan; Wang, Tianxue; Prakash, Vikas

    2017-03-01

    While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this paper, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ∼2.9 km/s. Sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

  11. Shiva optical diagnostics

    International Nuclear Information System (INIS)

    Rienecker, F.; Kobierecki, M.; Ozarski, R.; Seppala, L.; Manes, K.; Merritt, B.

    1977-01-01

    In the laser fusion program at Lawrence Livermore Laboratory, no target experiment is complete unless it is complemented by careful measurements of the laser pulse that irradiates the target. For this purpose, an incident beam diagnostics (IBD) package has been designed for the Shiva laser. The package will furnish data on items such as the total energy and the focusable energy out of the laser chain, and the spatial and temporal energy and power distribution at the target plane. Understanding laser-plasma interactions requires knowledge of the amount of 1.06 μm light energy that is scattered in various directions from the target. The light energy that is scattered toward the beam focusing lens is analyzed by a reflected beam diagnostic (RBD) package containing a calorimeter, a multiple image camera and a TV camera. This paper describes the detailed design and operation of the IBD and RBD packages as tools to align spatial filters and targets, as well as to diagnose the laser beams and target reflectivity

  12. Optical bistabilities of higher harmonics: Inhomogeneous and transverse effects

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, S.S., E-mail: Shoukryhassan@hotmail.com [Department of Mathematics, College of Science, University of Bahrain, P.O. Box 32038 (Bahrain); Manchester Metropolitan University, Dept. of Computing, Maths. and Digital Technology, Manchester M1 5GD (United Kingdom); Sharaby, Y.A., E-mail: Yasser_Sharaby@hotmail.com [Department of Physics, Faculty of Science, Suez Canal University, Suez (Egypt); Ali, M.F.M., E-mail: dr.mona.fathy@hotmail.com [Department of Mathematics: Faculty of Science, Ain Shams University, Cairo (Egypt); Joshi, A., E-mail: ajoshi@eiu.edu [Department of Physics, Eastern Illinois University, Charleston, IL 61920 (United States)

    2012-10-15

    The steady state behavior of optical bistable system in a ring cavity with transverse field variations and inhomogeneousely broadened two-level atoms is investigated outside the rotating wave approximation (RWA). Analytical and numerical investigation is presented for different cases of transverse field variations with Lorentzian or Gaussian line widths. When both (transverse and inhomogeneous) features taken into account, the first harmonic output field component outside the RWA exhibits a one-way switching down processes (butterfly OB) or reversed (clockwise) OB behavior, depending on the atomic linewidth shape.

  13. Optical bistabilities of higher harmonics: Inhomogeneous and transverse effects

    International Nuclear Information System (INIS)

    Hassan, S.S.; Sharaby, Y.A.; Ali, M.F.M.; Joshi, A.

    2012-01-01

    The steady state behavior of optical bistable system in a ring cavity with transverse field variations and inhomogeneousely broadened two-level atoms is investigated outside the rotating wave approximation (RWA). Analytical and numerical investigation is presented for different cases of transverse field variations with Lorentzian or Gaussian line widths. When both (transverse and inhomogeneous) features taken into account, the first harmonic output field component outside the RWA exhibits a one-way switching down processes (butterfly OB) or reversed (clockwise) OB behavior, depending on the atomic linewidth shape.

  14. TRANSVERSE OPTICS IMPROVEMENTS FOR RHIC RUN 4.

    Energy Technology Data Exchange (ETDEWEB)

    VAN ZEIJTS,J.

    2004-07-05

    The magnetic settings in RHIC are driven by an on-line model, and the quality of the resulting lattice functions depend on the correctness of the settings, and knowledge of the magnet transfer-functions. Here we first present the different inputs into the model, including dipole sextupole components, used to set tunes and chromaticities along the ramp. Based on an analysis of measured tunes along the FY03 polarized proton ramp, we present predictions for quadrupole transfer-function changes which have been implemented for the FY04 Au ramp. We show the improved model agreement for tunes along the ramp, and measured transverse phase-advance at store.

  15. Optical diagnostics for plasma etching

    NARCIS (Netherlands)

    Bisschops, T.H.J.; Kroesen, G.M.W.; Veldhuizen, van E.M.; de Zeeuw, C.J.H.; Timmermans, C.J.

    1985-01-01

    Several optical diagnostics were used to det. plasma properties and etch rates in an single wafer etch reactor. Results of UV-visible spectroscopy and IR absorption spectroscopy, indicating different mol. species and their densities are presented. The construction of an interferometer to det. the

  16. Transverse beam diagnostics for the XUV seeding experiment at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Boedewadt, Joern

    2011-12-15

    High-gain free-electron lasers (FEL) offer intense, transversely coherent, and ultra short radiation pulses in the extreme ultraviolet, the soft- and the hard-X-ray spectral range. Undulator radiation from spontaneous emission is amplified. Due to the stochastic emission process, the radiation exhibits a low temporal coherence, and the structure of the amplified radiation in the temporal and in the spectral domain shows large shot-to-shot fluctuations. In order to improve the temporal coherence, an external radiation pulse is used to induce (or seed) the FEL process. With this, only a defined wavelength range within the FEL bandwidth is amplified provided that the irradiance of the external radiation exceeds the noise level of the FEL amplifier. In addition to the improved longitudinal coherence, a seeded FEL provides the possibility to perform pump-probe experiments with an expected temporal resolution of the order of the pulse durations. In order to experimentally proof this statement, a test experiment for direct HHG-seeding at wavelength below 40 nm was installed at the free-electron laser facility FLASH at DESY. Crucial for the seeded operation of an FEL is the six-dimensional laser-electron overlap of the seed laser pulses with the electron bunches. Hence, dedicated diagnostics to measure and mechanisms to control the overlap are essential. Within this thesis, a transport beamline for the seed laser beam and the transverse diagnostics for seed laser- and the electron-beam were developed and commissioned. Results of the performance of the seed injection beamline are presented, and first measurements of the seeded operation of the FEL are analyzed and evaluated. (orig.)

  17. Transverse correlations in triphoton entanglement: Geometrical and physical optics

    International Nuclear Information System (INIS)

    Wen Jianming; Rubin, Morton H.; Shih Yanhua; Xu, P.

    2007-01-01

    The transverse correlation of triphoton entanglement generated within a single crystal is analyzed. Among many interesting features of the transverse correlation, they arise from the spectral function F of the triphoton state produced in the parametric processes. One consequence of transverse effects of entangled states is quantum imaging, which is theoretically studied in photon counting measurements. Klyshko's two-photon advanced-wave picture is found to be applicable to the multiphoton entanglement with some modifications. We found that in the two-photon coincidence counting measurement by using triphoton entanglement, although the Gaussian thin lens equation (GTLE) holds, the imaging shown in coincidences is obscure and has a poor quality. This is because of tracing the remaining transverse modes in the untouched beam. In the triphoton imaging experiments, two kinds of cases have been examined. For the case that only one object with one thin lens is placed in the system, we found that the GTLE holds as expected in the triphoton coincidences and the effective distance between the lens and imaging plane is the parallel combination of two distances between the lens and two detectors weighted by wavelengths, which behaves as the parallel combination of resistors in the electromagnetism theory. Only in this case, a point-point correspondence for forming an image is well-accomplished. However, when two objects or two lenses are inserted in the system, though the GTLEs are well-satisfied, in general a point-point correspondence for imaging cannot be established. Under certain conditions, two blurred images may be observed in the coincidence counts. We have also studied the ghost interference-diffraction experiments by using double slits as apertures in triphoton entanglement. It was found that when two double slits are used in two optical beams, the interference-diffraction patterns show unusual features compared with the two-photon case. This unusual behavior is a

  18. Transverse phase space mapping of relativistic electron beams using optical transition radiation

    Directory of Open Access Journals (Sweden)

    G. P. Le Sage

    1999-12-01

    Full Text Available Optical transition radiation (OTR has proven to be a versatile and effective diagnostic for measuring the profile, divergence, and emittance of relativistic electron beams with a wide range of parameters. Diagnosis of the divergence of modern high brightness beams is especially well suited to OTR interference (OTRI techniques, where multiple dielectric or metal foils are used to generate a spatially coherent interference pattern. Theoretical analysis of measured OTR and OTRI patterns allows precise measurement of electron beam emittance characteristics. Here we describe an extension of this technique to allow mapping of divergence characteristics as a function of transverse coordinates within a measured beam. We present the first experimental analysis of the transverse phase space of an electron beam using all optical techniques. Comparing an optically masked portion of the beam to the entire beam, we measure different angular spread and average direction of the particles. Direct measurement of the phase-space ellipse tilt angle has been demonstrated using this optical masking technique.

  19. Transverse effects in nonlinear optics: Toward the photon superfluid

    Science.gov (United States)

    McCormick, Colin Fraser

    Nonlinear optics displays a wealth of transverse effects. These effects are particularly rich in the presence of an optical cavity. Many considerations suggest that in a Kerr nonlinear cavity a new state of light known as a "photon superfluid" can form, with strong analogies to atomic superfluids. The conditions for the formation of the photon superfluid include requirements on the cavity, input light fields and the nonlinear medium as well as various timescales. The most favorable candidate nonlinear medium for observing the photon super-fluid is an atomic vapor. With a strong and fast Kerr effect, atomic vapors also have the advantage of a Kerr coefficient that is tunable in both magnitude and sign. A series of z-scan experiments in far-detuned atomic rubidium vapor is reported, measuring the Kerr coefficient and determining its functional dependence on detuning to be that of a Doppler-broadened two-level model with adiabatic following of the electric field by the atom pseudomoment. Saturation effects are found to be important. Z-scan measurements for detunings within the Doppler profile are shown to agree well with numerical simulations based on the Doppler-broadened model. Agreement between absorptive and refractive non-linear coefficients is evidence of the Kramers-Kronig relations at work, even in this nonlinear system. The formation of the photon superfluid is discussed and the calculation of a new process, nearly collinear four-wave mixing, is presented. This process is essentially an inverse beam filamentation that is likely to be the underlying physical mechanism for transverse cooling and condensation of photons in a nonlinear optical cavity. Nearly collinear four-wave mixing may also be related to phenomena in general nonlinear physics, including modulation instability and Fermi-Pasta-Ulam recurrence.

  20. A multislit transverse-emittance diagnostic for space-charge-dominated electron beams

    International Nuclear Information System (INIS)

    Piot, P.; Song, J.; Li, R.

    1997-01-01

    Jefferson Lab is developing a 10 MeV injector to provide an electron beam for a high-power free-electron laser (FEL). To characterize the transverse phase space of the space-charged-dominated beam produced by this injector, the authors designed an interceptive multislit emittance diagnostic. It incorporates an algorithm for phase-space reconstruction and subsequent calculation of the Twiss parameters and emittance for both transverse directions at an update rate exceeding 1 Hz, a speed that will facilitate the transverse-phase-space matching between the injector and the FEL's accelerator that is critical for proper operation. This paper describes issues pertaining to the diagnostic's design. It also discusses the acquisition system, as well as the software algorithm and its implementation in the FEL control system. First results obtained from testing this diagnostic in Jefferson Lab's Injector Test Stand are also included

  1. Elastography for Thyroid Nodules: The Comparison of Diagnostic Performance on Transverse and Longitudinal Planes

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kwak, Jin Young; Kim, Eun Kyung

    2012-01-01

    To evaluate the diagnostic performance of elastography for thyroid nodules on the transverse and longitudinal planes. Gray scale ultrasonography (US), elastography on trans- verse and longitudinal planes, and fine needle aspiration biopsy for 78 thyroid nodules (malignant: 34 cases, benign: 44 cases) were performed. According to the Asteria criteria of elastography, scores 1 and 2 were classified as probably benign and scores 3 and 4 were classified as suspicious. Strain ratios on transverse and longitudinal planes were measured. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and Az value (under the receiver operating characteristics curve) of elastography on transverse and longitudinal planes were calculated and compared. Scores 3 and 4 were more frequently seen in malignant nodules on the longitudinal plane (p value = 0.007), but not significantly seen on the transverse plane (p value = 0.160). Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and the Az value of elastography on the longitudinal plane were higher than those on the transverse plane, although Az values on the transverse and longtudinal planes were not statistically significant. Diagnostic performance of thyroid elastography, especially sensitivity, were higher on the longitudinal plane than the transverse plane

  2. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    International Nuclear Information System (INIS)

    Steffen, B.R.

    2007-07-01

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  3. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, B.R.

    2007-07-15

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  4. Proposal for electro-optic multiplier based on dual transverse electro-optic Kerr effect.

    Science.gov (United States)

    Li, Changsheng

    2008-10-20

    A novel electro-optic multiplier is proposed, which can perform voltage multiplication operation by use of the Kerr medium exhibiting dual transverse electro-optic Kerr effect. In this kind of Kerr medium, electro-optic phase retardation is proportional to the square of its applied electric field, and orientations of the field-induced birefringent axes are only related to the direction of the field. Based on this effect, we can design an electro-optic multiplier by selecting the crystals of 6/mmm, 432, and m3m classes and isotropic Kerr media such as glass. Simple calculation demonstrates that a kind of glass-ceramic material with a large Kerr constant can be used for the design of the proposed electro-optic multiplier.

  5. Flow diagnostics using fibre optics

    Indian Academy of Sciences (India)

    hypersonic vehicle with a 2-component fibre-optic strain-gauge balance. ... ment suffers a fall in accuracy to uncomfortable levels (more than 5%) and the measurement .... 15 kW motor with an associated thyristor speed-control system.

  6. Enhancement of the transverse magneto-optical Kerr effect via resonant tunneling in trilayers containing magneto-optical metals

    Energy Technology Data Exchange (ETDEWEB)

    Girón-Sedas, J. A. [Departamento de Física, Universidad del Valle, AA 25360, Cali (Colombia); Centro de Investigación e Innovación en Bioinformática y Fotónica - CIBioFI, AA 25360 Cali (Colombia); Mejía-Salazar, J. R., E-mail: jrmejia3146@gmail.com [Instituto de Física de São Carlos, Universidade de São Paulo, CP 369, 13560-970 São Carlos, SP (Brazil); Moncada-Villa, E.; Porras-Montenegro, N. [Departamento de Física, Universidad del Valle, AA 25360, Cali (Colombia)

    2016-07-18

    We propose a way to enhance the transverse magneto-optical Kerr effect, by the excitation of resonant tunneling modes, in subwavelength trilayer structures featuring a dielectric slab sandwiched between two magneto-optical metallic layers. Depending on the magneto-optical layer widths, the proposed system may exhibit an extraordinary transverse magneto-optical Kerr effect, which makes it very attractive for the design and engineering of thin-film magneto-optical-based devices for future photonic circuits or fiber optical-communication systems.

  7. Optical diagnostics of atmospheric pressure air plasmas

    International Nuclear Information System (INIS)

    Laux, C O; Spence, T G; Kruger, C H; Zare, R N

    2003-01-01

    Atmospheric pressure air plasmas are often thought to be in local thermodynamic equilibrium owing to fast interspecies collisional exchange at high pressure. This assumption cannot be relied upon, particularly with respect to optical diagnostics. Velocity gradients in flowing plasmas and/or elevated electron temperatures created by electrical discharges can result in large departures from chemical and thermal equilibrium. This paper reviews diagnostic techniques based on optical emission spectroscopy and cavity ring-down spectroscopy that we have found useful for making temperature and concentration measurements in atmospheric pressure plasmas under conditions ranging from thermal and chemical equilibrium to thermochemical nonequilibrium

  8. Optical fibres for fusion plasma diagnostics systems

    International Nuclear Information System (INIS)

    Brichard, B.

    2005-01-01

    The condition to achieve and maintain the ignition of a thermonuclear fusion plasma ignition calls for the construction of a large scale fusion reactor, namely ITER. This reactor is designed to deliver an average fusion power of 500 MW. The burning of fusion plasma at such high power level will release a tremendous amount of energy in the form of particle fluxes and ionising radiation. This energy release, primarily absorbed by the plasma facing components, can significantly degrade the performances of the plasma diagnostic equipment surrounding the machine. To ensure a correct operation of the Tokamak we need to develop highly radiation-resistance devices. In plasma diagnostic systems, optical fibre is viewed as a convenient tool to transport light from the plasma edge to the diagnostic area. Radiation affects the optical performances of the fibre mainly by the occurrence of radiation-induced absorption and luminescence. Both effects degrade the light signal used for plasma diagnostic. SCK-CEN is currently assessing radiation-resistant glasses for optical fibres and is developing the associated qualification procedure. The main objectives of this study were to increase the lifetime of optical components in high radiation background and to develop a radiation resistance optical fibre capable to operate in the radiation background of ITER

  9. Image transport through a disordered optical fibre mediated by transverse Anderson localization

    Science.gov (United States)

    Karbasi, Salman; Frazier, Ryan J.; Koch, Karl W.; Hawkins, Thomas; Ballato, John; Mafi, Arash

    2014-02-01

    Transverse Anderson localization of light allows localized optical-beam-transport through a transversely disordered and longitudinally invariant medium. Its successful implementation in disordered optical fibres recently resulted in the propagation of localized beams of radii comparable to that of conventional optical fibres. Here we demonstrate optical image transport using transverse Anderson localization of light. The image transport quality obtained in the polymer disordered optical fibre is comparable to or better than some of the best commercially available multicore image fibres with less pixelation and higher contrast. It is argued that considerable improvement in image transport quality can be obtained in a disordered fibre made from a glass matrix with near wavelength-size randomly distributed air-holes with an air-hole fill-fraction of 50%. Our results open the way to device-level implementation of the transverse Anderson localization of light with potential applications in biological and medical imaging.

  10. Optical coherence tomography and subclinical optical neuritis in longitudinally extensive transverse myelitis

    Directory of Open Access Journals (Sweden)

    Prakash Kumar Sinha

    2017-01-01

    Full Text Available Objective: The aim is to compare the retinal nerve fiber layer (RNFL thickness of longitudinally extensive transverse myelitis (LETM eyes without previous optic neuritis with that of healthy control subjects. Methods: Over 20 LETM eyes and 20 normal control eyes were included in the study and subjected to optical coherence tomography to evaluate and compare the RNFL thickness. Result: Significant RNFL thinning was observed at 8 o'clock position in LETM eyes as compared to the control eyes (P = 0.038. No significant differences were seen in other RNFL measurements. Conclusion: Even in the absence of previous optic neuritis LETM can lead to subclinical axonal damage leading to focal RNFL thinning.

  11. Spectroscopy and optical diagnostics for gases

    CERN Document Server

    Hanson, Ronald K; Goldenstein, Christopher S

    2016-01-01

    This text provides an introduction to the science that governs the interaction of light and matter (in the gas phase). It provides readers with the basic knowledge to exploit the light-matter interaction to develop quantitative tools for gas analysis (i.e. optical diagnostics) and understand and interpret the results of spectroscopic measurements. The authors pair the basics of gas‐phase spectroscopy with coverage of key optical diagnostic techniques utilized by practicing engineers and scientists to measure fundamental flow‐field properties. The text is organized to cover three sub‐topics of gas‐phase spectroscopy: (1) spectral line positions, (2) spectral line strengths, and (3) spectral lineshapes by way of absorption, emission, and scattering interactions. The latter part of the book describes optical measurement techniques and equipment. Key subspecialties include laser induced fluorescence, tunable laser absorption spectroscopy, and wavelength modulation spectroscopy. It is ideal for students an...

  12. A Study on the Transversal Optical Mode in Amorphous Gallium Arsenide

    OpenAIRE

    Grado-Caffaro, M. A.; Grado-Caffaro, M.

    1998-01-01

    Contributions to the far-infrared spectrum corresponding to both dynamical and structural disorders in a-GaAs are examined when frequency coincides with the transversal optical mode. Under these circumstances, dipole moment matrix element is discussed.

  13. Optical configuration with fixed transverse magnification for self-interference incoherent digital holography.

    Science.gov (United States)

    Imbe, Masatoshi

    2018-03-20

    The optical configuration proposed in this paper consists of a 4-f optical setup with the wavefront modulation device on the Fourier plane, such as a concave mirror and a spatial light modulator. The transverse magnification of reconstructed images with the proposed configuration is independent of locations of an object and an image sensor; therefore, reconstructed images of object(s) at different distances can be scaled with a fixed transverse magnification. It is yielded based on Fourier optics and mathematically verified with the optical matrix method. Numerical simulation results and experimental results are also given to confirm the fixity of the reconstructed images.

  14. Non-uniformly polarized beams across their transverse profiles: an introductory study for undergraduate optics courses

    International Nuclear Information System (INIS)

    Piquero, Gemma; Vargas-Balbuena, Javier

    2004-01-01

    We provide a simple theoretical study of beams non-uniformly polarized across their transverse sections which can be introduced in undergraduate optics courses. In order to generate such beams we propose to use a slightly convergent (or divergent) linearly and uniformly polarized beam impinging on an anisotropic uniaxial material with the beam propagation direction along the optic axis. Analytical expressions for the Jones vector, Stokes parameters, ellipticity and azimuth at each point of the transverse section, perpendicular to the propagation direction, are obtained at the output of this system. By means of these parameters a detailed description of the state of polarization across the transverse profile is given

  15. Modular initiator with integrated optical diagnostic

    Science.gov (United States)

    Alam, M Kathleen [Cedar Crest, NM; Schmitt, Randal L [Tijeras, NM; Welle, Eric J [Niceville, FL; Madden, Sean P [Arlington, MA

    2011-05-17

    A slapper detonator which integrally incorporates an optical wavequide structure for determining whether there has been degradation of the explosive in the explosive device that is to be initiated by the detonator. Embodiments of this invention take advantage of the barrel-like character of a typical slapper detonator design. The barrel assembly, being in direct contact with the energetic material, incorporates an optical diagnostic device into the barrel assembly whereby one can monitor the state of the explosive material. Such monitoring can be beneficial because the chemical degradation of the explosive plays an important in achieving proper functioning of a detonator/initiator device.

  16. A high repetition rate transverse beam profile diagnostic for laser-plasma proton sources

    Science.gov (United States)

    Dover, Nicholas; Nishiuchi, Mamiko; Sakaki, Hironao; Kando, Masaki; Nishitani, Keita

    2016-10-01

    The recently upgraded J-KAREN-P laser can provide PW peak power and intensities approaching 1022 Wcm-2 at 0.1 Hz. Scaling of sheath acceleration to such high intensities predicts generation of protons to near 100 MeV, but changes in electron heating mechanisms may affect the emitted proton beam properties, such as divergence and pointing. High repetition rate simultaneous measurement of the transverse proton distribution and energy spectrum are therefore key to understanding and optimising the source. Recently plastic scintillators have been used to measure online proton beam transverse profiles, removing the need for time consuming post-processing. We are therefore developing a scintillator based transverse proton beam profile diagnostic for use in ion acceleration experiments using the J-KAREN-P laser. Differential filtering provides a coarse energy spectrum measurement, and time-gating allows differentiation of protons from other radiation. We will discuss the design and implementation of the diagnostic, as well as proof-of-principle results from initial experiments on the J-KAREN-P system demonstrating the measurement of sheath accelerated proton beams up to 20 MeV.

  17. Application of Metal-Semiconductor-Metal (MSM) Photodetectors for Transverse and Longitudinal Intra-Bunch Beam Diagnostics

    CERN Document Server

    Steinhagen, R J; Boland, M J; Lucas, T G; Rassool, R P

    2013-01-01

    The performance reach of modern accelerators is often governed by the ability to reliably measure and control the beam stability. In high-brightness lepton and high-energy hadron accelerators, the use of optical diagnostic techniques is becoming more widespread as the required bandwidth, resolution and high RF beam power level involved limit the use of traditional electro-magnetic RF pick-up based methods. This contribution discusses the use of fibre-coupled ultra-fast Metal-Semiconductor-Metal Photodetectors (MSM-PD) as an alternative, dependablemeans to measure signals derived from electro-optical and synchrotron-light based diagnostics systems. It describes the beam studies performed at CERN’s CLIC Test Facility (CTF3) and the Australian Synchrotron to assess the feasibility of this technology as a robust, wide-band and sensitive technique for measuring transverse intra-bunch and bunch-by-bunch beam oscillations, longitudinal beam profiles, un-bunched beam population and beam-halo profiles. The amplifica...

  18. Transverse phase space diagnostics for ionization injection in laser plasma acceleration using permanent magnetic quadrupoles

    Science.gov (United States)

    Li, F.; Nie, Z.; Wu, Y. P.; Guo, B.; Zhang, X. H.; Huang, S.; Zhang, J.; Cheng, Z.; Ma, Y.; Fang, Y.; Zhang, C. J.; Wan, Y.; Xu, X. L.; Hua, J. F.; Pai, C. H.; Lu, W.; Mori, W. B.

    2018-04-01

    We report the transverse phase space diagnostics for electron beams generated through ionization injection in a laser-plasma accelerator. Single-shot measurements of both ultimate emittance and Twiss parameters are achieved by means of permanent magnetic quadrupole. Beams with emittance of μm rad level are obtained in a typical ionization injection scheme, and the dependence on nitrogen concentration and charge density is studied experimentally and confirmed by simulations. A key feature of the transverse phase space, matched beams with Twiss parameter α T ≃ 0, is identified according to the measurement. Numerical simulations that are in qualitative agreement with the experimental results reveal that a sufficient phase mixing induced by an overlong injection length leads to the matched phase space distribution.

  19. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  20. Optical, x-ray and microwave diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Tudisco, S.; Mascali, D.; Altana, C.; Anzalone, A.; Gammino, S.; Musumarra, A.; Musumeci, F.; Scordino, A. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); Romano, F. P. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); IBAM-CNR, Via Biblioteca 4, 95100 Catania (Italy); Tramontana, A. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy)

    2013-07-26

    Laser-driven ion acceleration is a new approach for the particles acceleration, which allows obtaining ion beams with unique properties, such as short burst duration, large particle number, small size source size, low transverse emittance. Currently, two main acceleration mechanisms have been identified and investigated: target normal sheath acceleration (TNSA) and radiation pressure acceleration (RPA). Electrons dynamics and energies are strongly coupled to these acceleration mechanisms and they can be investigated with optical and X-ray techniques. The main aim of these studies are the identification of few physical observables that can be directly correlated to the proton emission obtained (in terms of reproducibility and intensity) in operations with different target material and structure and laser-target interaction parameters.

  1. Silver nanoparticles as optical clearing agent enhancers to improve caries diagnostic by optical coherence tomography

    Science.gov (United States)

    Carneiro, Vanda S. M.; Mota, Cláudia C. B. O.; Souza, Alex F.; da Silva, Evair J.; da Silva, Andrea F.; Gerbi, Marleny E. M. M.; Gomes, Anderson S. L.

    2018-02-01

    The use of silver nanoparticles as optical clearing agent (OCA) enhancers to improve caries diagnostic by optical coherence tomography (OCT) is demonstrated here. Five molars with no evident cavitation were selected. The OCAs were based on aqueous solution of silver nanoparticles (AgNP, 1.18x 1014 particles/mL, ø ≈ 10nm) and its dilution at 10% in glycerol. Teeth were placed on a platform with a micrometric screw, and after applying the OCAs, they were scanned with a Callisto SD-OCT system operating ate 930nm central wavelength. The occlusal surfaces were scanned by OCT, capturing crosssectional images with 8 mm transversal scanning, generating numerical matrices (2000x512). The OCT images had their transverse dimension preserved. AgNP-OCAs promoted image stretching due to the modification in the light optical path caused by AgNP-OCAs refractive indices close to that of the enamel. AgNP-OCAs evidenced the enamel birefringence and highlighted initial demineralization areas, that presented defined margins with higher contrast between sound and demineralized regions, with higher OCT signal intensity in those areas.

  2. Optical spectra analysis for breast cancer diagnostics

    Science.gov (United States)

    Belkov, S. A.; Kochemasov, G. G.; Lyubynskaya, T. E.; Maslov, N. V.; Nuzhny, A. S.; da Silva, L. B.; Rubenchik, A.

    2011-11-01

    Minimally invasive probe and optical biopsy system based on optical spectra recording and analysis seem to be a promising tool for early diagnostics of breast cancer. Light scattering and absorption spectra are generated continuously as far as the needle-like probe with one emitting and several collecting optical fibers penetrates through the tissues toward to the suspicious area. That allows analyzing not only the state of local site, but also the structure of tissues along the needle trace. The suggested method has the advantages of automated on-line diagnosing and minimal tissue destruction and in parallel with the conventional diagnostic procedures provides the ground for decision-making. 165 medical trials were completed in Nizhny Novgorod Regional Oncology Centre, Russia. Independent diagnoses were the results of fine biopsy and histology. Application of wavelet expansion and clasterization techniques for spectra analysis revealed several main spectral types for malignant and benign tumors. Automatic classification algorithm demonstrated specificity ˜90% and sensitivity ˜91%. Large amount of information, fuzziness in criteria and data noisiness make neural networks to be an attractive analytic tool. The model based on three-layer perceptron was tested over the sample of 29 `cancer' and 29 `non-cancer' cases and demonstrated total separation.

  3. Role of transverse-momentum currents in the optical Magnus effect in free space

    OpenAIRE

    Luo, Hailu; Wen, Shuangchun; Shu, Weixing; Fan, Dianyuan

    2010-01-01

    We establish a general vector field model to describe the role of transverse-momentum currents in the optical Magnus effect in free space. As an analogy of the mechanical Magnus effect, the circularly polarized wave packet in our model acts as the rotating ball, and its rotation direction depends on the polarization state. Based on this model, we demonstrate the existence of an optical polarization-dependent Magnus effect which is significantly different from the conventional optical Magnus e...

  4. Role of transverse-momentum currents in the optical Magnus effect in free space

    International Nuclear Information System (INIS)

    Luo Hailu; Wen Shuangchun; Shu Weixing; Fan Dianyuan

    2010-01-01

    We establish a general vector field model to describe the role of transverse-momentum currents in the optical Magnus effect in free space. As an analogy of the mechanical Magnus effect, the circularly polarized wave packet in our model acts as the rotating ball, and its rotation direction depends on the polarization state. Based on this model, we demonstrate the existence of an optical polarization-dependent Magnus effect which is significantly different from the conventional optical Magnus effect in that light-matter interaction is not required. Further, we reveal the relation between transverse-momentum currents and the optical Magnus effect, and find that such a polarization-dependent rotation is unavoidable when the wave packet possesses transverse-momentum currents. The physics underlying this intriguing effect is the combined contributions of transverse spin and orbital currents. We predict that this effect may be observed experimentally even in the propagation direction. These findings provide further evidence for the optical Magnus effect in free space and can be extrapolated to other physical systems.

  5. A new generation of optical diagnostics for bladder cancer: technology, diagnostic accuracy, and future applications

    NARCIS (Netherlands)

    Cauberg, Evelyne C. C.; de Bruin, Daniël M.; Faber, Dirk J.; van Leeuwen, Ton G.; de La Rosette, Jean J. M. C. H.; de Reijke, Theo M.

    2009-01-01

    CONTEXT: New developments in optical diagnostics have a potential for less invasive and improved detection of bladder cancer. OBJECTIVE: To provide an overview of the technology and diagnostic yield of recently developed optical diagnostics for bladder cancer and to outline their potential future

  6. Multispectral optical tweezers for molecular diagnostics of single biological cells

    Science.gov (United States)

    Butler, Corey; Fardad, Shima; Sincore, Alex; Vangheluwe, Marie; Baudelet, Matthieu; Richardson, Martin

    2012-03-01

    Optical trapping of single biological cells has become an established technique for controlling and studying fundamental behavior of single cells with their environment without having "many-body" interference. The development of such an instrument for optical diagnostics (including Raman and fluorescence for molecular diagnostics) via laser spectroscopy with either the "trapping" beam or secondary beams is still in progress. This paper shows the development of modular multi-spectral imaging optical tweezers combining Raman and Fluorescence diagnostics of biological cells.

  7. Emittance control of a beam by shaping the transverse charge distribution, using a tomography diagnostic

    International Nuclear Information System (INIS)

    Yakimenko, V.; Babzien, M.; Ben-Zvi, I.; Malone, R.; Wang, X.J.

    1998-06-01

    A high-brightness beam is very important for many applications. A diagnostic that measures the multi-dimensional phase-space density-distribution of the electron bunch is a must for obtaining such beams. Measurement of a slice emittance has been achieved. Tomographic reconstruction of phase space was suggested and implemented using a single quadrupole scan. In the present work the authors give special attention to the accuracy of the phase space reconstruction and present an analysis using a transport line with nine focusing magnets and techniques to control the optical functions and phases. This diagnostic, coupled with control of the radial charge distribution of presents an opportunity to improve the beam brightness. Combining the slice emittance and tomography diagnostics lead to an unprecedented visualization of phase space distributions in 5 dimensional phase-space and an opportunity to perform high-order emittance corrections

  8. Production of Coherent xuv and soft-x-ray light using a transverse optical klystron

    International Nuclear Information System (INIS)

    Kincaid, B.M.; Freeman, R.R.

    1984-01-01

    This section describes the theory of the production of coherent xuv radiation and soft x rays using a transverse optical klystron (TOK). A TOK uses a high-power laser in conjunction with an undulator magnet to produce laserlike output of xuv radiation from a relativistic electron beam. 16 references, 5 figures

  9. Neutron optics using transverse field neutron spin echo method

    International Nuclear Information System (INIS)

    Achiwa, Norio; Hino, Masahiro; Yamauchi, Yoshihiro; Takakura, Hiroyuki; Tasaki, Seiji; Akiyoshi, Tsunekazu; Ebisawa, Toru.

    1993-01-01

    A neutron spin echo (NSE) spectrometer with perpendicular magnetic field to the neutron scattering plane, using an iron yoke type electro-magnet has been developed. A combination of cold neutron guider, supermirror neutron polarizer of double reflection type and supermirror neutron analyser was adopted for the spectrometer. The first application of the NSE spectrometer to neutron optics by passing Larmor precessing neutrons through gas, solid and liquid materials of several different lengths which are inserted in one of the precession field have been examined. Preliminary NSE spectra of this sample geometry are discussed. (author)

  10. Dynamics analysis of microsphere in a dual-beam fiber-optic trap with transverse offset.

    Science.gov (United States)

    Chen, Xinlin; Xiao, Guangzong; Luo, Hui; Xiong, Wei; Yang, Kaiyong

    2016-04-04

    A comprehensive dynamics analysis of microsphere has been presented in a dual-beam fiber-optic trap with transverse offset. As the offset distance between two counterpropagating beams increases, the motion type of the microsphere starts with capture, then spiral motion, then orbital rotation, and ends with escape. We analyze the transformation process and mechanism of the four motion types based on ray optics approximation. Dynamic simulations show that the existence of critical offset distances at which different motion types transform. The result is an important step toward explaining physical phenomena in a dual-beam fiber-optic trap with transverse offset, and is generally applicable to achieving controllable motions of microspheres in integrated systems, such as microfluidic systems and lab-on-a-chip systems.

  11. Optical method for mapping the transverse phase space of a charged particle beam

    International Nuclear Information System (INIS)

    Fiorito, R.B.; Shkvarunets, A.G.; O'Shea, P.G.

    2002-01-01

    We are developing an all optical method to map the transverse phase space map of a charged particle beam. Our technique employs OTR interferometry (OTRI) in combination with a scanning pinhole to make local orthogonal (x,y) divergence and trajectory angle measurements as function of position within the transverse profile of the beam. The localized data allows a reconstruction of the horizontal and vertical phase spaces of the beam. We have also demonstrated how single and multiple pinholes can in principle be used to make such measurements simultaneously

  12. Production of coherent XUV and soft x-rays using a transverse optical klystron

    International Nuclear Information System (INIS)

    Freeman, R.R.; Kincaid, B.J.

    1984-01-01

    An optical klystron is a device in which a relativistic electron beam produces coherent electromagnetic radiation by interacting with an external laser beam in an undulator magnetic field. Such a device represents the relativistic generalization of the microwave klystron. The device is called transverse optical klystron (TOK), because the energy exchange between the electrons and the light in this case is due to the transverse electric field of the laser. The generation of coherent light by the TOK can be considered as a three step process, including energy modulation, compaction or bunching, and radiation. In the present paper, a description is provided of the general physical principles underlying the operation of each of the three sections of the TOK, taking into account the modulator, the compactor, and the radiator. 14 references

  13. All-solid tellurite optical fiber with transversely disordered refractive index profile and its optical image transport performance

    Science.gov (United States)

    Tong, Hoang Tuan; Kuroyanagi, Shunei; Suzuki, Takenobu; Ohishi, Yasutake

    2018-02-01

    All-solid tellurite-glass optical rod and fiber with transversely-disordered refractive index profile were successfully fabricated to study the transport of infrared images by using transverse localization of light. The fabrication was carried out by using stack-and-draw and rod-in-tube techniques. The fabricated tellurite optical rod and fiber were composed of high-index and low-index units which were arranged randomly in the transverse plane but were invariant in the longitudinal direction. The diameter of each unit was approximately 1.0 μm. The high-index and low-index materials were TeO2-Li2O-WO3-MoO3-Nb2O5 (TLWMN) glass and TeO2-ZnO-Na2O-La2O3 (TZNL) glass, respectively. At 1550 nm, their refractive index difference Δn is 0.096. To investigate the optical image transport capability, A CW laser light at 1550 nm was used as an input probe beam and the 1951 U.S. Air Force test target was installed in front of 10-cm-long segments of the fabricated rod and fiber in the experimental setup. The output signal was recorded by a beam profiler. As a result, clear transported images of numbers and lines on the test target were obtained.

  14. Experimental characterization of X-ray transverse coherence in the presence of beam transport optics

    DEFF Research Database (Denmark)

    Chubar, O.; Fluerasu, A.; Chu, Y.S.

    2013-01-01

    A simple Boron fiber based interference scheme [1] and other similar schemes are currently routinely used for X-ray coherence estimation at 3rd generation synchrotron radiation sources. If such a scheme is applied after a perfect monochromator and without any focusing / transport optics...... in the optical path, the interpretation of the measured interference pattern is relatively straightforward and can be done in terms of the basic parameters of the source [2]. However, if the interference scheme is used after some focusing optics, e.g. close to the X-ray beam waist, the visibility of fringes can...... be significantly affected by the new shape of the focused beam phase-space. At the same time, optical element imperfections still have a negative impact on the transverse coherence. In such situations, which are frequently encountered in experiments at beamlines, the quantitative interpretation of a measured...

  15. Optical Diagnostics of Thermal Barrier Coatings

    Science.gov (United States)

    Majewski, Mark Steven

    The high temperature properties of ceramic materials make them suitable for the extreme environments of gas combustion powered turbines. They are instrumental in providing thermal insulation for the metallic turbine components from the combustion products. Also, the addition of specific rare earth elements to ceramics creates materials with temperature diagnostic applications. Laser based methods have been applied to these ceramic coatings to predict their remaining thermal insulation service life and to explore their high temperature diagnostic capabilities. A method for cleaning thermal barrier coatings (TBCs) contaminated during engine operation has been developed using laser ablation. Surface contamination on the turbine blades hinders nondestructive remaining life prediction using photo luminescence piezospectroscopy (PLPS). Real time monitoring of the removed material is employed to prevent damage to the underlying coating. This method relies on laser induced breakdown spectroscopy (LIBS) to compute the cross correlation coefficient between the spectral emissions of a sample TBC that is contaminated and a reference clean TBC. It is possible to remove targeted contaminants and cease ablation when the top surface of the TBC has been reached. In collaboration with this work, Kelley's thesis [1] presents microscopy images and PLPS measurements indicating the integrity of the TBC has been maintained during the removal of surface contaminants. Thermographic phosphors (TGP) have optical emission properties when excited by a laser that are temperature dependent. These spectral and temporal properties have been investigated and utilized for temperature measurement schemes by many previous researchers. The compounds presented in this dissertation consist of various rare earth (Lanthanide) elements doped into a host crystal lattice. As the temperature of the lattice changes, both the time scale for vibrational quenching and the distribution of energy among atomic energy

  16. Visualization of Longitudinal and Transverse Components of Strongly Focused Optical Field by means of Photo-Reactive Azopolymers

    Directory of Open Access Journals (Sweden)

    Kharitonov A.V.

    2015-01-01

    Full Text Available Most important problems in modern photonics are fabrication, visualization and characterization of nanomaterials at optical frequencies. A number of optical techniques uses tightly focused laser beams to access longitudinal electromagnetic fields, which are directed towards the wave vector. In this Letter, the distribution of transverse and longitudinal optical fields in tightly focused laser beams, polarized in a new fashion, is investigated. Polarization dependent fingerprints of transverse and longitudinal optical fields are experimentally captured by means of photoinduced surface deformations in azobenzene polymer thin films.

  17. Waveguide-Plasmon Polaritons Enhance Transverse Magneto-Optical Kerr Effect

    Directory of Open Access Journals (Sweden)

    Lars E. Kreilkamp

    2013-11-01

    Full Text Available Magneto-optical effects in ferrimagnetic or ferromagnetic materials are usually too weak for potential applications. The transverse magneto-optical Kerr effect (TMOKE in ferromagnetic films is typically on the order of 0.1%. Here, we demonstrate experimentally the enhancement of TMOKE due to the interaction of particle plasmons in gold nanowires with a photonic waveguide consisting of magneto-optical material, where hybrid waveguide-plasmon polaritons are excited. We achieve a large TMOKE that modulates the transmitted light intensity by 1.5%, accompanied by high transparency of the system. Our concept may lead to novel devices of miniaturized photonic circuits and switches, which are controllable by an external magnetic field.

  18. Transverse energy circulation and the edge diffraction of an optical vortex beam.

    Science.gov (United States)

    Bekshaev, Aleksandr Ya; Mohammed, Kadhim A; Kurka, Ivan A

    2014-04-01

    Edge diffraction of a circular Laguerre-Gaussian beam represents an example of the optical vortex symmetry breakdown in which the hidden "vortex" energy circulation is partially transformed into the visible "asymmetry" form. The diffracted beam evolution is studied in terms of the irradiance moments and the moment-based parameters. In spite of the limited applicability of the moment-based formalism, we show that the "vortex" and "asymmetry" parts of the orbital angular momentum can still be reasonably defined for the hard-edge diffracted beams and retain their physical role of quantifying the corresponding forms of the transverse energy circulation.

  19. A study of a transverse optical klystron experiment in adone (TOKA)

    International Nuclear Information System (INIS)

    Boscolo, I.; Stagno, V.; Bari Univ.

    1982-01-01

    The storage ring operation of a free electron laser (FEL) can be improved by a prebunching of the electron beam. We study in this paper a layout working as a transverse optical klystron (TOK). The enhancement of the single pass gain and the consequent reduction of the wiggler length in the TOK compared with the FEL suggests that the first device is more suitable for a storage ring such as Adone, where the straight sections are about 2 m long. The figures of the TOKA are carried out using as much as possible the hardware of the FEL experiment which is in progress at Adone (LELA experiment). (orig.)

  20. Optical diagnostics in the advanced test accelerator (ATA) environment

    International Nuclear Information System (INIS)

    Chong, Y.P.; Cornish, J.P.; Donnelly, D.

    1987-05-01

    The ATA is a 50-MeV, 10-kA, 70-ns pulsed electron beam accelerator that generates an extremely harsh environment for diagnostic measurements. Diagnostic targets placed in the beamline are subject to damage, frequently being destroyed by a single pulse. High radiation (x-ray, gamma, and neutron) and electromagnetic interference levels preclude placing components near the beamline that are susceptible to radiation damage. Examples of such components are integrated circuit elements, hydrocarbons such as Teflon insulation, and optical components that darken, resulting in transmission loss. Optical diagnostics play an important part in measuring experimental parameters such as the beam current density profile. A large number of optical lines of sight (LOS) are routinely deployed along the experimental beamlines that use the ATA beam. Gated TV cameras are located outside the accelerator tunnel, because the tunnel is inaccessible during operations. We will describe and discuss the difficulties, problems, and solutions encountered in making optical measurements in the ATA environment

  1. DNA Diagnostics: Optical or by Electronics?

    KAUST Repository

    Khan, Hadayat Ullah; Knoll, Wolfgang

    2016-01-01

    In this paper, we very briefly review DNA biosensors based on optical and electrical detection principles, referring mainly to our past work applying both techniques but here using nearly identical sensor chip surface architectures, i.e., capture

  2. Optical coherence tomography evaluation of retinal nerve fiber layer in longitudinally extensive transverse myelitis

    Directory of Open Access Journals (Sweden)

    Frederico C. Moura

    2011-02-01

    Full Text Available OBJECTIVE: To compare optical coherence tomography (OCT measurements on the retinal nerve fiber layer (RNFL of healthy controls and patients with longitudinally extensive transverse myelitis (LETM without previous optic neuritis. METHOD: Twenty-six eyes from 26 patients with LETM and 26 control eyes were subjected to automated perimetry and OCT for comparison of RNFL measurements. RESULTS: The mean deviation values from perimetry were significantly lower in patients with LETM than in controls (p<0.0001. RNFL measurements in the nasal quadrant and in the 3-o'clock segment were significantly smaller in LETM eyes than in controls. (p=0.04 and p=0.006, respectively. No significantly differences in other RNFL measurements were found. CONCLUSION: Patients with LETM may present localized RNFL loss, particularly on the nasal side of the optic disc, associated with slight visual field defects, even in the absence of previous episodes of optic neuritis. These findings emphasize the fact that patients with LETM may experience attacks of subclinical optic nerve damage.

  3. Optimization of Pockels electric field in transverse modulated optical voltage sensor

    Science.gov (United States)

    Huang, Yifan; Xu, Qifeng; Chen, Kun-Long; Zhou, Jie

    2018-05-01

    This paper investigates the possibilities of optimizing the Pockels electric field in a transverse modulated optical voltage sensor with a spherical electrode structure. The simulations show that due to the edge effect and the electric field concentrations and distortions, the electric field distributions in the crystal are non-uniform. In this case, a tiny variation in the light path leads to an integral error of more than 0.5%. Moreover, a 2D model cannot effectively represent the edge effect, so a 3D model is employed to optimize the electric field distributions. Furthermore, a new method to attach a quartz crystal to the electro-optic crystal along the electric field direction is proposed to improve the non-uniformity of the electric field. The integral error is reduced therefore from 0.5% to 0.015% and less. The proposed method is simple, practical and effective, and it has been validated by numerical simulations and experimental tests.

  4. Diagnostic Accuracy of the Volume Rendering Images of Multi-Detector CT for the Detection of Lumbar Transverse Process Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Hak; Chun, Tong Jin [Dept. of Radiology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2012-01-15

    To compare the accuracy of three-dimensional computed tomographic (3D CT) volume rendering techniques with axial images of multi-detector row computed tomography to identify lumbar transverse process (LTP) fractures in trauma patients. We retrospectively evaluated 42 patients with back pain as a result of blunt trauma between January and June of 2010. Two radiologists examined the 3D CT volume rendering images independently. The confirmation of a LTP fracture was based on the consensus of the axial images by the two radiologists. The results of 3D CT volume rendering images were compared with the axial images and the diagnostic powers (sensitivity, specificity, and accuracy) were calculated. Seven of the 42 patients had twenty five lumbar transverse process fractures. The diagnostic power of the 3D CT volume rendering technique is as accurate as axial images. Reader 1, sensitivity 96%, specificity 100%, accuracy 99.9%; and Reader 2 sensitivity 100%, specificity 99.8%, accuracy 99.8%. The accordance of the two radiologists was 99.8%. 3D CT volume rendering images can alternate axial images to detect lumbar transverse process fractures with good image quality.

  5. Optical diagnostics of a gliding arc

    DEFF Research Database (Denmark)

    Sun, Z.W.; Zhu, J.J.; Li, Z.S.

    2013-01-01

    Dynamic processes in a gliding arc plasma generated between two diverging electrodes in ambient air driven by 31.25 kHz AC voltage were investigated using spatially and temporally resolved optical techniques. The life cycles of the gliding arc were tracked in fast movies using a high-speed camera...... triggered by Townsend breakdown between the two legs of the gliding arc. The emission from the plasma column is shown to pulsate at a frequency of 62.5 kHz, i.e., twice the frequency of the AC power supply. Optical emission spectra of the plasma radiation show the presence of excited N2, NO and OH radicals...... suggesting that ground-state OH is not formed in the plasma column but in its vicinity. ©2013 Optical Society of America...

  6. Optical coherence tomography as a diagnostic tool

    CSIR Research Space (South Africa)

    Singh, A

    2011-07-01

    Full Text Available Optical Coherence Tomography (OCT) has been used in biomedical applications as a method to non-invasively detect changes occurring in tissue such as the detection of skin cancer. The effect of skin tone on detection of skin cancer has however...

  7. Parity-time symmetry optics for modal selection in transverse and longitudinal waves (Conference Presentation)

    Science.gov (United States)

    Benisty, Henri; Lupu, Anatole

    2017-05-01

    The evolving field of optics for information and communication is currently seeking directions to expand the data rates in all concerned devices, fiber-based or on chips. We describe here two possibilities where the new concept of PT-symmetry in optics [1,2] can be exploited to help high data rate operation, considering either transverse or longitudinal aspects of modal selection, and assuming that data are carried using precise modes. The first aspect is transverse multimode transport. In this case, a fiber or a waveguide carries a few modes, say 4 to 16, and at nodes, they have to undergo a demux/mux operation to add or drop a subset of them, as much as possible without affecting the others. We shall consider to this end the operation as described in ref. [3] : if a PT-symmetric "potential", which essentially consists of a transverse gain-loss profile with antisymmetry, is applied to a waveguide, it has a very different impact on the different modes and mode families in the waveguide. One can in particular find situations where only two modes of the passive waveguide to be analyzed may enter into a gain regime, and not the other ones. From this scheme and others [4], we will discuss what is the road left towards an actual device, either in dielectrics or in case plasmonics is envisioned [5], i.e. with rather constant losses, but the possible advantage of miniaturization. The second aspect is longitudinal mode selection. The special transport properties of PT-symmetric Bragg gratings are now well established. In order to be used within a data management system, attention has to be paid to the rejection rate of Bragg gratings, and to the flatness of their response in the targeted window. To this end, a slow modulation of both real and imaginary parts of the periodic pattern of the basically PT-symmetric waveguide can help, in the general spirit of "apodization", but now with more parameters. We will detail some aspects of the designs introduced in [6] , notably

  8. Optical diagnostics in gas turbine combustors

    Science.gov (United States)

    Woodruff, Steven D.

    1999-01-01

    Deregulation of the power industry and increasingly tight emission controls are pushing gas turbine manufacturers to develop engines operating at high pressure for efficiency and lean fuel mixtures to control NOx. This combination also gives rise to combustion instabilities which threaten engine integrity through acoustic pressure oscillations and flashback. High speed imaging and OH emission sensors have been demonstrated to be invaluable tools in characterizing and monitoring unstable combustion processes. Asynchronous imaging technique permit detailed viewing of cyclic flame structure in an acoustic environment which may be modeled or utilized in burner design . The response of the flame front to the acoustic pressure cycle may be tracked with an OH emission monitor using a sapphire light pipe for optical access. The OH optical emission can be correlated to pressure sensor data for better understanding of the acoustical coupling of the flame. Active control f the combustion cycle can be implemented using an OH emission sensor for feedback.

  9. Transverse nucleon structure and diagnostics of hard parton-parton processes at LHC

    Energy Technology Data Exchange (ETDEWEB)

    L. Frankfurt, M. Strikman, C. Weiss

    2011-03-01

    We propose a new method to determine at what transverse momenta particle production in high-energy pp collisions is governed by hard parton-parton processes. Using information on the transverse spatial distribution of partons obtained from hard exclusive processes in ep/\\gamma p scattering, we evaluate the impact parameter distribution of pp collisions with a hard parton-parton process as a function of p_T of the produced parton (jet). We find that the average pp impact parameters in such events depend very weakly on p_T in the range 2 < p_T < few 100 GeV, while they are much smaller than those in minimum-bias inelastic collisions. The impact parameters in turn govern the observable transverse multiplicity in such events (in the direction perpendicular to the trigger particle or jet). Measuring the transverse multiplicity as a function of p_T thus provides an effective tool for determining the minimum p_T for which a given trigger particle originates from a hard parton-parton process.

  10. INTEGRATED APPLICATION OF OPTICAL DIAGNOSTIC METHODS IN ULCERATIVE COLITIS

    Directory of Open Access Journals (Sweden)

    E. V. Velikanov

    2013-01-01

    Full Text Available Abstract. Our results suggest that the combined use of optical coherent tomography (OCT and fluorescence diagnosis helps to refine the nature and boundaries of the pathological process in the tissue of the colon in ulcerative colitis. Studies have shown that an integrated optical diagnostics allows us to differentiate lesions respectively to histology and to decide on the need for biopsy and venue. This method is most appropriate in cases difficult for diagnosis. 

  11. Noncritical quadrature squeezing in two-transverse-mode optical parametric oscillators

    International Nuclear Information System (INIS)

    Navarrete-Benlloch, Carlos; Roldan, Eugenio; Valcarcel, German J. de; Romanelli, Alejandro

    2010-01-01

    In this article we explore the quantum properties of a degenerate optical parametric oscillator when it is tuned to the first family of transverse modes at the down-converted frequency. Recently we found [C. Navarrete-Benlloch et al., Phys. Rev. Lett. 100, 203601 (2008)] that above threshold a TEM 10 mode following a random rotation in the transverse plane emerges in this system (we denote it as the bright mode), breaking thus its rotational invariance. Then, owing to the mode orientation being undetermined, we showed that the phase quadrature of the transverse mode orthogonal to this one (denoted as the dark mode) is perfectly squeezed at any pump level and without an increase in the fluctuations on its amplitude quadrature (which seems to contradict the uncertainty principle). In this article we go further in the study of this system and analyze some important features not considered previously. First we show that the apparent violation of the uncertainty principle is just that -'apparent' - as the conjugate pair of the squeezed quadrature is not another quadrature but the orientation of the bright mode (which is completely undetermined in the long term). We also study a homodyne scheme in which the local oscillator is not perfectly matched to the dark mode, as this could be impossible in real experiments due to the random rotation of the mode, showing that even in this case large levels of noise reduction can be obtained (also including the experimentally unavoidable phase fluctuations). Finally, we show that neither the adiabatic elimination of the pump variables nor the linearization of the quantum equations are responsible for the remarkable properties of the dark mode (which we prove analytically and through numerical simulations, respectively), which were simplifying assumptions used in Navarrete-Benlloch et al. [Phys. Rev. Lett. 100, 203601 (2008)]. These studies show that the production of noncritically squeezed light through spontaneous rotational

  12. DNA Diagnostics: Optical or by Electronics?

    KAUST Repository

    Khan, Hadayat Ullah

    2016-01-15

    In this paper, we very briefly review DNA biosensors based on optical and electrical detection principles, referring mainly to our past work applying both techniques but here using nearly identical sensor chip surface architectures, i.e., capture probe layers that were prepared based on a pulsed plasma deposition protocol for maleic anhydride and subsequent wet-chemical attachment of the amine-functionalized peptide nucleic acid (PNA) probe oligonucleotides. 15 mer DNA target strands, labeled with Cy5-chromophores that were attached at the 5’ end were used for surface plasmon optical detection and the same target DNA but without label was used in OTFT sensor-based detection where the mere charge density of the bound (hybridized) DNA molecules modulate the source-drain current. The sensing mechanisms and the detection limits of the devices are described in some detail. Both techniques allow for the monitoring of surface hybridization reactions, and offer the capacity to quantitatively discriminate between targets with different degrees of mismatched sequences.

  13. Optical signal acquisition and processing in future accelerator diagnostics

    International Nuclear Information System (INIS)

    Jackson, G.P.; Elliott, A.

    1992-01-01

    Beam detectors such as striplines and wall current monitors rely on matched electrical networks to transmit and process beam information. Frequency bandwidth, noise immunity, reflections, and signal to noise ratio are considerations that require compromises limiting the quality of the measurement. Recent advances in fiber optics related technologies have made it possible to acquire and process beam signals in the optical domain. This paper describes recent developments in the application of these technologies to accelerator beam diagnostics. The design and construction of an optical notch filter used for a stochastic cooling system is used as an example. Conceptual ideas for future beam detectors are also presented

  14. Longitudinal versus transversal excitation in doped graded-index polymer optical fibers

    Science.gov (United States)

    Illarramendi, M. A.; Arrue, J.; Ayesta, I.; Jiménez, F.; Zubia, J.; Bikandi, I.; Tagaya, A.; Koike, Y.

    2014-03-01

    In this work we perform a detailed experimental and theoretical analysis of the properties of amplified spontaneous emission (ASE) in a rhodamine-6G-doped graded-index polymer optical fiber when the fiber is pumped either longitudinally or transversally with respect to the fiber axis. The dependence of the ASE threshold and efficiency on fiber length has been compared for both schemes of excitation. A theoretical model for longitudinal excitation has been carried out by means of the laser rate equations as functions of time, distance traveled by light and wavelength. The analysis takes into account that the fiber is a typical graded-index POF in which the radial distributions of light power density and dye concentration are not uniform. The theoretical calculations agree satisfactorily with the experimental results. The photodegradation of the ASE intensity has also been measured for both pumping schemes.

  15. Multi-Directional Optical Diagnostics of Thermal Plasma Jets

    Czech Academy of Sciences Publication Activity Database

    Hlína, Jan; Chvála, František; Šonský, Jiří; Gruber, Jan

    2008-01-01

    Roč. 19, č. 1 (2008), s. 1-6 ISSN 0957-0233 R&D Projects: GA ČR(CZ) GA202/05/0728 Institutional research plan: CEZ:AV0Z20570509 Keywords : thermal plasma jet * optical diagnostics * Radon transform Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.493, year: 2008

  16. TV-acquired optical diagnostics systems on ATA

    International Nuclear Information System (INIS)

    Kalibjian, R.; Chong, Y.P.; Cornish, J.P.; Jackson, C.H.; Fessenden, T.J.

    1984-06-01

    The purpose of this paper is to report on optical system developments on the ATA and their applications to ATA beam characterization. Television (TV)-acquired optical diagnostics data provide spatial and temporal properties of the ATA beam that complements recorded information from other types of sensors, such as, beam-wall current monitors, x-ray probes, and rf probes. The ATA beam operates: (1) in the normal mode at 50-MeV, 10-kA at a 1-Hz rate; and (2) in the 1-KHz burst mode (for 10-pulses) at a 0.5 Hz rate. The beam has a 70-ns pulse width in vacuum propagation; however, beam-head erosion will occur in atmospheric propagation, thus limiting the pulse width to less than 50-ns. Various optical systems are used for ATA diagnostics. Optical-imaging provides a convenient measurement in a single pulse of the 2-dimensional profile of the beam intensity. It can also provide multiple 2-D framing in a single pulse. In some studies it may be desirable to study optical events with temporal resolution less than 100-ps with 1-dimensional streak cameras. Spatially integrated data from phototube cameras can also be used for background measurement applications as well as for single pixel monitoring. The optical line-of-sight (LOS) configurations have been made versatile to accommodate a large number of options for the various optical systems

  17. Simultaneously improving optical absorption of both transverse-electric polarized and transverse-magnetic polarized light for organic solar cells with Ag grating used as transparent electrode

    Directory of Open Access Journals (Sweden)

    Yongbing Long

    2014-08-01

    Full Text Available Theoretical simulations are performed to investigate optical performance of organic solar cells with Ag grating electrode. It is demonstrated that optical absorption for both transverse-electric (TE polarized and transverse-magnetic(TM polarized light is simultaneously improved when compared with that for the device without the Ag grating. The improvement is respectively attributed to the resonance and the surface plasmon polaritons within the device. After an additional WO3 layer is capped on the Ag grating, absorption of TE-polarized light is further improved due to resonance of double microcavities within the device, and absorption of TM-polarized light is improved by the combined effects of the microcavity resonance and the surface plasmon polaritons. Correspondingly, the short current density for randomly polarized light is improved by 18.1% from that of the device without the Ag grating. Finally, it is demonstrated that high transmission may not be an essential prerequisite for metallic gratings when they are used as transparent electrode since absorption loss caused by low transmission can be compensated by using a capping layer to optimize optical resonance of the WMC structure within the device.

  18. Some optical diagnostics for the plasma focus

    International Nuclear Information System (INIS)

    Korzhavin, V.M.

    1980-01-01

    Some aspects of studying plasma focus dynamics are reported. Particular efforts were made to develop an infrared (IR) diagnostics. The plasma focus is formed in a discharge chamber, when shock waves and plasma sheath cumulate on the axis as a result of the break-down of filling gas by the application of high voltage. The current J was measured with a Rogovsky coil, and the voltage U was measured with a capacitor divider. The current derivative was measured with magnetic probes, and X-ray and neutron emission intensities were measured with a plastic scintillator. The total neutron yield were measured by the activation method. The time-integrated soft X-ray pictures of plasma focus were taken with a pin-hole camera. The formation and disruption of plasma focus were studied by multi-picture speed photography. Laser interferometry was used to study the time-space distribution of plasma density. For the study of turbulence phenomena in plasma focus, a new type IR detector was employed. The results of measurements suggest that there exists some superthermal radiation during the second compression of plasma focus, but it is not so strong. (Kato, T.)

  19. Linac-beam characterizations at 600 MeV using optical transition radiation diagnostics.

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H.

    1998-05-27

    Selected optical diagnostics stations were upgraded in anticipation of low-emittance, bright electron beams from a thermionic rf gun or a photoelectric rf gun on the Advanced Photon Source (APS) injector linac. These upgrades include installation of optical transition radiation (OTR) screens, transport lines, and cameras for use in transverse beam size measurements and longitudinal profile measurements. Using beam from the standard thermionic gun, tests were done at 50 MeV and 400 to 650 MeV. Data were obtained on the limiting spatial ({sigma} {approximately} 200 {micro}m) and temporal resolution (300 ms) of the Chromox (Al{sub 2}O{sub 3} : Cr) screen (250-{micro}n thick) in comparison to the OTR screens. Both charge-coupled device (CCD) and charge-injection device (CID) video cameras were used as well as the Hamamatsu C5680 synchroscan streak camera operating at a vertical deflection rate of 119.0 MHz (the 24th subharmonic of the S-band 2856-MHz frequency). Beam transverse sizes as small as {sigma}{sub x} = 60 {micro}m for a 600-MeV beam and micropulse bunch lengths of {sigma}{sub {tau}}<3 ps have been recorded for macropulse-averaged behavior with charges of about 2 to 3 nC per macropulse. These techniques are applicable to linac-driven, fourth-generation light source R and D experiments including the APS's SASE FEL experiment.

  20. Intraoral fiber optic-based diagnostic for periodontal disease

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P W; Gutierrez, D M; Everett, M J; Brown, S B; Langry, K C; Colston, B W; Roe, J N

    2000-01-21

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic sensor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research tool.

  1. Intraoral fiber-optic-based diagnostic for periodontal disease

    Science.gov (United States)

    Colston, Bill W., Jr.; Gutierrez, Dora M.; Everett, Matthew J.; Brown, Steve B.; Langry, Kevin C.; Cox, Weldon R.; Johnson, Paul W.; Roe, Jeffrey N.

    2000-05-01

    The purpose of this initial study was to begin development of a new, objective diagnostic instrument that will allow simultaneous quantitation of multiple proteases within a single periodontal pocket using a chemical fiber optic senor. This approach could potentially be adapted to use specific antibodies and chemiluminescence to detect and quantitate virtually any compound and compare concentrations of different compounds within the same periodontal pocket. The device could also be used to assay secretions in salivary ducts or from a variety of wounds. The applicability is, therefore, not solely limited to dentistry and the device would be important both for clinical diagnostics and as a research too.

  2. Fibre-optic laser-assisted infrared tumour diagnostics (FLAIR)

    Science.gov (United States)

    Bindig, U.; Müller, G.

    2005-08-01

    Laser based fibre-optic surgery procedures are commonly used in minimal invasive surgery. Despite the development of precise and efficient laser systems there are also innovative attempts in the field of bio-medical diagnostics. As a direct result of the tissue's optical properties most applications are focused on the visible wavelength range of the spectrum. The extension of the spectrum up to the mid-infrared (IR) region will offer a broad range of possibilities for novel strategies with a view to non-invasive diagnostics in medicine. We describe a method to detect differences between diseased and normal tissues, which involve Fourier transform IR microspectroscopy and fibre-optics methods. Regions of interest on 10 µm thin tissue sections were mapped using an IR microscope in transmission mode. After IR-mapping, the samples were analysed using standard pathological techniques. Quadratic discriminant and correlation analyses were applied to the IR maps obtained allowing differentiation between cancerous and normal tissue. The use of optical fibres, transparent in the mid-IR, allowed measurements to be made in the attenuated total reflectance (ATR)-mode at a remote location. The IR sensor is in contact with the sample that shows characteristic absorption lines. The total transmission of the fibre and the sample will decrease at these lines. This method can be used to determine the absorption of a sample in a non-destructive manner. In this paper we report on our efforts to develop an IR fibre-optic sensor for tissue identification as well as to differentiate between malignant and healthy tissue in vivo. We also describe the technical design of the laboratory set-up and the results of developments made. Silver halide fibres and a special sensor tip were used for the ATR measurements on tissue specimens. The results indicate that fibre-optic IR spectrometry will be a useful tool for bio-diagnostics.

  3. Fibre-optic laser-assisted infrared tumour diagnostics (FLAIR)

    International Nuclear Information System (INIS)

    Bindig, U; Mueller, G

    2005-01-01

    Laser based fibre-optic surgery procedures are commonly used in minimal invasive surgery. Despite the development of precise and efficient laser systems there are also innovative attempts in the field of bio-medical diagnostics. As a direct result of the tissue's optical properties most applications are focused on the visible wavelength range of the spectrum. The extension of the spectrum up to the mid-infrared (IR) region will offer a broad range of possibilities for novel strategies with a view to non-invasive diagnostics in medicine. We describe a method to detect differences between diseased and normal tissues, which involve Fourier transform IR microspectroscopy and fibre-optics methods. Regions of interest on 10 μm thin tissue sections were mapped using an IR microscope in transmission mode. After IR-mapping, the samples were analysed using standard pathological techniques. Quadratic discriminant and correlation analyses were applied to the IR maps obtained allowing differentiation between cancerous and normal tissue. The use of optical fibres, transparent in the mid-IR, allowed measurements to be made in the attenuated total reflectance (ATR)-mode at a remote location. The IR sensor is in contact with the sample that shows characteristic absorption lines. The total transmission of the fibre and the sample will decrease at these lines. This method can be used to determine the absorption of a sample in a non-destructive manner. In this paper we report on our efforts to develop an IR fibre-optic sensor for tissue identification as well as to differentiate between malignant and healthy tissue in vivo. We also describe the technical design of the laboratory set-up and the results of developments made. Silver halide fibres and a special sensor tip were used for the ATR measurements on tissue specimens. The results indicate that fibre-optic IR spectrometry will be a useful tool for bio-diagnostics

  4. Design and engineering of optical diagnostics for COMPASS

    Czech Academy of Sciences Publication Activity Database

    Šesták, David; Weinzettl, Vladimír; Bílková, Petra; Böhm, Petr; Aftanas, Milan; Naydenkova, Diana; Stöckel, Jan; Ďuran, Ivan; Walsh, M.J.

    2009-01-01

    Roč. 84, 7-11 (2009), s. 1755-1758 ISSN 0920-3796. [Symposium on Fusion Technology(SOFT-25) /25th./. Rostock, 15.09.2008-19.09.2008] R&D Projects: GA ČR GD202/08/H057 Institutional research plan: CEZ:AV0Z20430508 Keywords : COMPASS * tokamak * optical diagnostic * Thomson scattering Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.122, year: 2009

  5. Correlation diagnostics of random spatially nonuniform optical fields

    International Nuclear Information System (INIS)

    Angel'skii, O.V.

    1992-01-01

    This review examines some questions concerning the capabilities of interference and polarization-interference correlation diagnostics of the amplitude-phase characteristics of random optical fields for the purpose of identifying these fields and then studying the corresponding objects. The diagnostics of random phase objects is discussed separately in the case in which the phase dispersion of the inhomogeneities is less than and greater than one. The outlook is promising for the use of the correlation dimensionality of chaos in a field as a diagnostic parameter. It is also shown that the use of interference principles for a parallel processing of large data files can substantially increase the speed of processing systems. 32 refs., 8 figs

  6. Factors affecting the transverse force measurements of an optical trap: I

    Science.gov (United States)

    Wood, Tiffany A.; Wright, Amanda; Gleeson, Helen F.; Dickenson, Mark; Mullin, Tom; Murray, Andrew

    2002-03-01

    The transverse force of an optical trap is usually measured by equating the trapping force to the viscous drag force applied to the trapped particle according to Stokes' Law. Under normal conditions, the viscous drag force on a trapped particle is proportional to the fluid velocity of the medium. In this paper we show that an increase of particle concentration within the medium affects force measurements. In order to trap the particle, 1064 nm light from a Nd:YVO4 laser was brought to a focus in a sample slide, of thickness around 380 microns, by using an inverted Zeiss microscope objective, with NA equals 1.3. The slide was filled with distilled water containing 6 micron diameter polystyrene spheres. Measurements were taken at a fluid velocity of 0.75 microns/sec, achieved by moving the sample stage with a piezo-electric transducer whilst a particle was held stationary in the trap. The laser power required to hold a sphere at different trap depths for various concentrations was measured. Significant weakening of the trap was found for concentrations >0.03% solids by weight, becoming weaker for higher trap depths. These results are explained in terms of aberrations, particle-particle interactions and distortion of the beam due to particle-light interactions.

  7. Optical diagnostics of mercury jet for an intense proton target.

    Science.gov (United States)

    Park, H; Tsang, T; Kirk, H G; Ladeinde, F; Graves, V B; Spampinato, P T; Carroll, A J; Titus, P H; McDonald, K T

    2008-04-01

    An optical diagnostic system is designed and constructed for imaging a free mercury jet interacting with a high intensity proton beam in a pulsed high-field solenoid magnet. The optical imaging system employs a backilluminated, laser shadow photography technique. Object illumination and image capture are transmitted through radiation-hard multimode optical fibers and flexible coherent imaging fibers. A retroreflected illumination design allows the entire passive imaging system to fit inside the bore of the solenoid magnet. A sequence of synchronized short laser light pulses are used to freeze the transient events, and the images are recorded by several high speed charge coupled devices. Quantitative and qualitative data analysis using image processing based on probability approach is described. The characteristics of free mercury jet as a high power target for beam-jet interaction at various levels of the magnetic induction field is reported in this paper.

  8. High speed manyframe optical methods for plasma diagnostics

    International Nuclear Information System (INIS)

    Erokhin, A.A.; Shikanov, A.S.; Sklizkov, G.V.; Zakharenkov, Yu.A.; Zorev, N.N.

    1979-01-01

    A complex of active optical plasma and strong ionized shock wave diagnostics is described. The complex consisted of a specially developed high speed manyframe systems of shadow, schlieren and interferometric photography. The comparison of results obtained by a simultaneous registration of investigated object by means of different optical methods allowed us to determine optimal employment range for the methods. The sensitivity, temporal and space resolution of each optical method under conditions of high probe radiation refraction are discussed. The application boundaries of these methods for ionized shock wave investigation were found to depend on the shock wave front width. The methods described were used for the study of laser-produced plasma phenomena, occuring in the experiments on powerful nine-channel laser installation ''Kalmar''. (author)

  9. A Method to Assess Transverse Vibration Energy of Ship Propeller Shaft for Diagnostic Purposes

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2017-12-01

    Full Text Available The article discusses a key problem of ship propulsion system vibration diagnostics, which concerns assessing this part of mechanical energy transmitted from the main engine to the ship propeller which is dissipated due to propeller shaft vibration. A simplified calculation model is proposed which allows the total energy of the generated torsional vibration to be assessed from the shaft deflection amplitude measured at the mind-span point between the supports. To verify the developed model, pilot tests were performed on the laboratory rotational mechanical system test rig. In those tests, cyclic bending moment was applied to a unified (cylindrical material sample, which modelled, at an appropriate scale, structural and functional properties of a real propeller shaft.

  10. Optical beam diagnostics at the Electron Stretcher Accelerator ELSA

    International Nuclear Information System (INIS)

    Zander, Sven

    2013-10-01

    At the ELectron Stretcher Accelerator ELSA, a resonant excitation of the horizontal particle oscillations is used to extract the electrons to the experiments. This so-called resonance extraction influences the properties of the extracted beam. The emittance, as a number of the beam quality, was determined by using synchrotron light monitors. To enable broad investigations of the emittance a system of synchrotron light monitors was set up. This system was used to measure the influence of the extraction method on the emittance. Time resolved measurements were conducted to investigate the development of the emittance during an accelerator cycle. To improve the optical beam diagnostics a new beamline to an external laboratory was constructed. There, a new high resolution synchrotron light monitor was commissioned. In addition, a streak camera has been installed to enable longitudinal diagnostics of the beam profiles. First measurements of the longitudinal charge distribution with a time resolution in the range of a few picoseconds were conducted successfully.

  11. Strange metal from Gutzwiller correlations in infinite dimensions: Transverse transport, optical response, and rise of two relaxation rates

    Science.gov (United States)

    Ding, Wenxin; Žitko, Rok; Shastry, B. Sriram

    2017-09-01

    Using two approaches to strongly correlated systems, the extremely correlated Fermi liquid theory and the dynamical mean field theory, we compute the transverse transport coefficients, namely, the Hall constants RH and Hall angles θH, and the longitudinal and transverse optical response of the U =∞ Hubbard model in the limit of infinite dimensions. We focus on two successive low-temperature regimes, the Gutzwiller-correlated Fermi liquid (GCFL) and the Gutzwiller-correlated strange metal (GCSM). We find that the Hall angle cotθH is proportional to T2 in the GCFL regime, while upon warming into the GCSM regime it first passes through a downward bend and then continues as T2. Equivalently, RH is weakly temperature dependent in the GCFL regime, but becomes strongly temperature dependent in the GCSM regime. Drude peaks are found for both the longitudinal optical conductivity σx x(ω ) and the optical Hall angles tanθH(ω ) below certain characteristic energy scales. By comparing the relaxation rates extracted from fitting to the Drude formula, we find that in the GCFL regime there is a single relaxation rate controlling both longitudinal and transverse transport, while in the GCSM regime two different relaxation rates emerge. We trace the origin of this behavior to the dynamical particle-hole asymmetry of the Dyson self-energy, arguably a generic feature of doped Mott insulators.

  12. Optical diagnostics of streamer discharges in atmospheric gases

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan

    2014-01-01

    Roč. 47, č. 46 (2014), s. 463001-463001 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GAP205/12/1709 Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100431201 Program:M Institutional support: RVO:61389021 Keywords : streamer * optical diagnostics * laser-induced fluorescence * LIF * TALIF * red-sprite Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.721, year: 2014 http://iopscience.iop.org/0022-3727/47/46/463001/pdf/0022-3727_47_46_463001.pdf

  13. Survey Talk--New Laser and Optical Radiation Diagnostics

    International Nuclear Information System (INIS)

    Leemans, W.P.

    1998-01-01

    New techniques am reported for electron beam monitoring, that rely either on the analysis of the properties of wiggler radiation (from static magnetic fields as well as from laser ''undulators'', also referred to as Thomson scattering) or on the non-linear mixing of laser radiation with electron beam radiation. The different techniques reviewed are capable of providing information on femtosecond time scales and micron or even sub-micron spatial scales. The laser undulator is also proposed as a useful tool for non- destructive measurement of high power electron beams. An example is given of measuring electron beam energy and energy spread through spectral filtering of spontaneous wiggler radiation [1]. A novel technique based on fluctuational characteristics of radiation is described, for single shot, nondestructive measurement of the electron beam bunch length [2,3]. Thomson scattering based beam monitoring techniques are discussed which, through analysis of the radiated beam properties, allow non-destructive detailed measurement of transverse and longitudinal distributions of relativistic electron beams [4]. Two new techniques are discussed which rely on non-linear optical mixing of laser radiation with electron bunch emission: differential optical gating (DOG) [5] and electron bunch length measurement in a storage ring based on sum-frequency generation [6

  14. Scanning microscopy of magnetic domains using the Fe 3p core level transverse magneto-optical Kerr effect

    Science.gov (United States)

    Friedrich, J.; Rozhko, I.; Voss, J.; Hillebrecht, F. U.; Kisker, E.; Wedemeier, V.

    1999-04-01

    We demonstrate the feasibility of the vacuum ultraviolet analog to visible-light magneto-optical imaging of magnetic structures using the resonantly enhanced transverse magneto-optical Kerr effect at core level thresholds with incident p-polarized radiation. The advantages are element specificity and a variable information depth. We used the scanning x-ray microscope at HASYLAB capable of obtaining about 1 μm resolution by means of its focusing ellipsoidal ring mirror. The p-polarized component of the reflected light was selected using multilayer reflection at an additional plane mirror downstream to the sample. Micrographs of the optical reflectivity were taken in the vicinity of the Fe 3p core level threshold at 53.7 and 56.5 eV photon energy where the magneto-optical effect is of opposite sign. Magnetic domains are visible in the difference of both recorded images.

  15. Applications of optical fibers in nuclear test diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.; Hodson, E.K.; Looney, L.D.

    1980-01-01

    Two new plasma diagnostic experiments have been successfully fielded on nuclear device tests at NTS. Both systems rely on the unique advantages provided by optical fiber technology and both systems provide new diagnostic capabilities that previously were beyond the state-of-the-art in coaxial cable systems. One system addresses the need to record e wide bandwidth data on gamma-ray sources. Over the long (< 1 km) distances that characterize NTS testing, the bandwidth of coaxial cable systems is usually limited to < 200 to 400 MHz even with extensive equalization. The new system uses the Cerenkov process to generate light in a converter material. High bandwidth fibers and detectors are used to approach a 1-GHz bandwidth. In this case fibers provided the bandwidth capability. The second system provides time and space resolution of a neutron source on a fast (ns) time scale. Previous systems have utilized either an array of neutron detectors with individual coaxial cables or a fast scintillator viewed by a gated image intensifier. For a large number of channels, the coaxial system becomes very costly and is subject to potentially severe EMI concerns. The gated intensifier system requires complex electronics and accurate timing and can be affected by EMI. An alternative system is described which provides continuous time coverage with limited spatial resolution. Complete freedom from EMI is achieved through the use of optical data collection and transmission. The optical fibers offered a major (2 to 3 times) cost savings and a large weight savings relative to the coax system. Each system is discussed

  16. Fiber Optic Strain Sensor for Planetary Gear Diagnostics

    Science.gov (United States)

    Kiddy, Jason S.; Lewicki, David G.; LaBerge, Kelsen E.; Ehinger, Ryan T.; Fetty, Jason

    2011-01-01

    This paper presents a new sensing approach for helicopter damage detection in the planetary stage of a helicopter transmission based on a fiber optic strain sensor array. Complete helicopter transmission damage detection has proven itself a difficult task due to the complex geometry of the planetary reduction stage. The crowded and complex nature of the gearbox interior does not allow for attachment of sensors within the rotating frame. Hence, traditional vibration-based diagnostics are instead based on measurements from externally mounted sensors, typically accelerometers, fixed to the gearbox exterior. However, this type of sensor is susceptible to a number of external disturbances that can corrupt the data, leading to false positives or missed detection of potentially catastrophic faults. Fiber optic strain sensors represent an appealing alternative to the accelerometer. Their small size and multiplexibility allows for potentially greater sensing resolution and accuracy, as well as redundancy, when employed as an array of sensors. The work presented in this paper is focused on the detection of gear damage in the planetary stage of a helicopter transmission using a fiber optic strain sensor band. The sensor band includes an array of 13 strain sensors, and is mounted on the ring gear of a Bell Helicopter OH-58C transmission. Data collected from the sensor array is compared to accelerometer data, and the damage detection results are presented

  17. Idiopathic Transverse Myelitis and Neuromyelitis Optica: Clinical Profiles, Pathophysiology and Therapeutic Choices

    Science.gov (United States)

    Awad, Amer; Stüve, Olaf

    2011-01-01

    Transverse myelitis is a focal inflammatory disorder of the spinal cord which may arise due to different etiologies. Transverse myelitis may be idiopathic or related/secondary to other diseases including infections, connective tissue disorders and other autoimmune diseases. It may be also associated with optic neuritis (neuromyelitis optica), which may precede transverse myelitis. In this manuscript we review the pathophysiology of different types of transverse myelitis and neuromyelitis optica and discuss diagnostic criteria for idiopathic transverse myelitis and risk of development of multiple sclerosis after an episode of transverse myelitis. We also discuss treatment options including corticosteroids, immunosuppressives and monoclonal antibodies, plasma exchange and intravenous immunoglobulins. PMID:22379456

  18. Application of optical phase conjugation to plasma diagnostics (invited)

    International Nuclear Information System (INIS)

    Jahoda, F.C.; Anderson, B.T.; Forman, P.R.; Weber, P.G.

    1985-01-01

    Several possibilities for plasma diagnostics provided by optical phase conjugation and, in particular, self-pumped phase conjugation in barium titanate (BaTiO 3 ) are discussed. These include placing a plasma within a dye laser cavity equipped with a phase conjugate mirror for intracavity absorption measurements, time differential refractometry with high spatial resolution, and simplified real-time holographic interferometry. The principles of phase conjugation with particular reference to photorefractive media and the special advantages of self-pumped phase conjugation are reviewed prior to the discussion of the applications. Distinctions are made in the applications between those for which photorefractive conjugators are essential and those for which they only offer experimental simplification relative to other types of phase conjugators

  19. Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

    Science.gov (United States)

    Tabibi, Bagher M.; Terrell, Charles A.; Spraggins, Darrell; Lee, Ja. H.; Weinstein, Leonard M.

    1997-01-01

    Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

  20. Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Loree, T.R.; Mourant, J.; Shimada, T. [Los Alamos National Lab., NM (United States); Story-Held, K.; Glickman, R.D. [Texas Univ. Health Science Center, San Antonio, TX (United States). Dept. of Ophthalmology; Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States). Dept. of Urology

    1993-08-01

    A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength dependence of elastic scattering. The data acquisition and storage/display time with the OBS instrument is {approximately}1 second. Thus, in addition to the reduced invasiveness of this technique compared with current state-of-the-art methods (surgical biopsy and pathology analysis), the OBS offers the possibility of impressively faster diagnostic assessment. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope, catheter or hypodermic, or to direct surface examination (e.g. as in skin cancer or cervical cancer). It has been tested in vitro on animal and human tissue samples, and clinical testing in vivo is currently in progress.

  1. Optical diagnostics on the Magnetized Shock Experiment (MSX)

    Science.gov (United States)

    Boguski, J. C.; Weber, T. E.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.; Hutchinson, T. M.; Gao, K. W.

    2013-10-01

    The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high Alfvén Mach number, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. A suite of optical diagnostics has recently been fielded on MSX to characterize plasma conditions during the formation, acceleration, and stagnation phases of the experiment. CCD-backed streak and framing cameras, and a fiber-based visible light array, provide information regarding FRC shape, velocity, and instability growth. Time-resolved narrow and broadband spectroscopy provides information on pre-shock plasma temperature, impurity levels, shock location, and non-thermal ion distributions within the shock region. Details of the diagnostic design, configuration, and characterization will be presented along with initial results. This work is supported by the Center for Magnetic Self Organization, DoE OFES and NNSA under LANS contract DE-AC52-06NA25369. Approved for public release: LA-UR- 13-25190.

  2. Dome diagnostics system of optical parameters and characteristics of LEDs

    Science.gov (United States)

    Peretyagin, Vladimir S.; Pavlenko, Nikita A.

    2017-09-01

    Scientific and technological progress of recent years in the production of the light emitting diodes (LEDs) has led to the expansion of areas of their application from the simplest systems to high precision lighting devices used in various fields of human activity. However, development and production (especially mass production) of LED lighting devices are impossible without a thorough analysis of its parameters and characteristics. There are many ways and devices for analysis the spatial, energy and colorimetric parameters of LEDs. The most methods are intended for definition only one parameter (for example, luminous flux) or one characteristic (for example, the angular distribution of energy or the spectral characteristics). Besides, devices used these methods are intended for measuring parameters in only one point or plane. This problem can be solved by using a dome diagnostics system of optical parameters and characteristics of LEDs, developed by specialists of the department OEDS chair of ITMO University in Russia. The paper presents the theoretical aspects of the analysis of LED's spatial (angular), energy and color parameters by using mentioned of diagnostics system. The article also presents the results of spatial), energy and color parameters measurements of some LEDs brands.

  3. Optical diagnostics based on elastic scattering: An update of clinical demonstrations with the Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Boyer, J.; Johnson, T.M.; Lacey, J.; Mourant, J.R. [Los Alamos National Lab., NM (United States); Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States); Bohorfoush, A. [Wisconsin Medical School, Milwaukee, WI (United States)

    1994-10-01

    The Los Alamos National Laboratory has continued the development of the Optical Biopsy System (OBS) for noninvasive, real-time in situ diagnosis of tissue pathologies. Our clinical studies have expanded since the last Biomedical Optics Europe conference (Budapest, September 1993), and we report here on the latest results of clinical tests in gastrointestinal tract. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength-dependence of elastic scattering. The OBS employs a small fiberoptic probe that is amenable to use with any endoscope or catheter, or to direct surface examination. The probe is designed to be used in optical contact with the tissue under examination and has separate illuminating and collecting fibers. Thus, the light that is collected and transmitted to the analyzing spectrometer must first scatter through a small volume of the tissue before entering the collection fiber(s). Consequently, the system is also sensitive to the optical absorption spectrum of the tissue, over an effective operating range of <300 to 950 nm, and such absorption adds valuable complexity to the scattering spectral signature.

  4. Vertical vs. transverse sections of scalp biopsy specimens: a pilot study on the comparison of the diagnostic value of two techniques in alopecia.

    Science.gov (United States)

    Özcan, D; Özen, Ö; Seçkin, D

    2011-12-01

    Using both vertical and transverse sections is preferred for histopathological diagnosis of alopecia. However, in cases in which only a single biopsy is taken, it is not clear which type of sectioning is better. To compare the diagnostic value of transverse and vertical sections. In total, 53 patients with alopecia were enrolled in the study. Two biopsies were taken from each patient, and cut into either transverse or vertical sections. The clinical and histopathological findings were evaluated together for the definitive diagnosis. After the study period, a pathologist randomly re-evaluated the sections. We compared the histopathological diagnoses with the definitive diagnoses, and determined the sensitivity and specificity of each method. A definitive diagnosis was made for 47 patients (88.7%). Of these, 30 (63.8%) had noncicatricial and 17 (36.2%) had cicatricial alopecia, and the diagnosis was made by transverse and vertical sections for 43 (91.5%) and 39 (88%), respectively (P > 0.05; sensitivity; 91.5% vs. 82%). All 30 patients with noncicatricial alopecia were diagnosed by transverse sections, and 25 (83.3%) of the 30 were diagnosed with vertical sections (P = 0.05; sensitivity 100% vs. 83.3%). Of the 17 patients with cicatricial alopecia, 13 (76.5%) and 14 (82.4%) patients were diagnosed by transverse and vertical sections, respectively (P > 0.05; sensitivity 76.5% vs. 82.4%). Five patients with lichen planopilaris were diagnosed by vertical sections, and one by transverse sections. There were several limitations to the study: (i) statistical subtype analysis could be performed only for alopecia areata; (ii) no conclusion could be drawn about the interobserver reliability of two sections; and (iii) having the pathologist-blinded study performed retrospectively might have caused a recall bias. If only a single biopsy specimen is available, it may be preferable to have transverse sections in cases of suspected noncicatricial alopecia, and vertical sections in

  5. Deep cooling of optically trapped atoms implemented by magnetic levitation without transverse confinement

    Science.gov (United States)

    Li, Chen; Zhou, Tianwei; Zhai, Yueyang; Xiang, Jinggang; Luan, Tian; Huang, Qi; Yang, Shifeng; Xiong, Wei; Chen, Xuzong

    2017-05-01

    We report a setup for the deep cooling of atoms in an optical trap. The deep cooling is implemented by eliminating the influence of gravity using specially constructed magnetic coils. Compared to the conventional method of generating a magnetic levitating force, the lower trap frequency achieved in our setup provides a lower limit of temperature and more freedoms to Bose gases with a simpler solution. A final temperature as low as ˜ 6 nK is achieved in the optical trap, and the atomic density is decreased by nearly two orders of magnitude during the second stage of evaporative cooling. This deep cooling of optically trapped atoms holds promise for many applications, such as atomic interferometers, atomic gyroscopes, and magnetometers, as well as many basic scientific research directions, such as quantum simulations and atom optics.

  6. A high-resolution optical imaging system for obtaining the serial transverse section images of biologic tissue

    Science.gov (United States)

    Wu, Li; Zhang, Bin; Wu, Ping; Liu, Qian; Gong, Hui

    2007-05-01

    A high-resolution optical imaging system was designed and developed to obtain the serial transverse section images of the biologic tissue, such as the mouse brain, in which new knife-edge imaging technology, high-speed and high-sensitive line-scan CCD and linear air bearing stages were adopted and incorporated with an OLYMPUS microscope. The section images on the tip of the knife-edge were synchronously captured by the reflection imaging in the microscope while cutting the biologic tissue. The biologic tissue can be sectioned at interval of 250 nm with the same resolution of the transverse section images obtained in x and y plane. And the cutting job can be automatically finished based on the control program wrote specially in advance, so we save the mass labor of the registration of the vast images data. In addition, by using this system a larger sample can be cut than conventional ultramicrotome so as to avoid the loss of the tissue structure information because of splitting the tissue sample to meet the size request of the ultramicrotome.

  7. Electro-optical properties of zigzag and armchair boron nitride nanotubes under a transverse electric field: Tight binding calculations

    Science.gov (United States)

    Chegel, Raad; Behzad, Somayeh

    2012-02-01

    The electro-optical properties of zigzag and armchair BNNTs in a uniform transverse electric field are investigated within tight binding approximation. It is found that the electric field modifies the band structure and splits band degeneracy where these effects reflect in the DOS and JDOS spectra. A decrease in the band gap, as a function of the electric field, is observed. This gap reduction increases with the diameter and it is independent of chirality. An analytic function to estimate the electric field needed for band gap closing is proposed which is in good agreement with DFT results. In additional, we show that the larger diameter tubes are more sensitive than small ones. Number and position of peaks in DOS and JDOS spectra for armchair and zigzag tubes with similar radius are dependent on electric field strength.

  8. Quantitative optical diagnostics in pathology recognition and monitoring of tissue reaction to PDT

    Science.gov (United States)

    Kirillin, Mikhail; Shakhova, Maria; Meller, Alina; Sapunov, Dmitry; Agrba, Pavel; Khilov, Alexander; Pasukhin, Mikhail; Kondratieva, Olga; Chikalova, Ksenia; Motovilova, Tatiana; Sergeeva, Ekaterina; Turchin, Ilya; Shakhova, Natalia

    2017-07-01

    Optical coherence tomography (OCT) is currently actively introduced into clinical practice. Besides diagnostics, it can be efficiently employed for treatment monitoring allowing for timely correction of the treatment procedure. In monitoring of photodynamic therapy (PDT) traditionally employed fluorescence imaging (FI) can benefit from complementary use of OCT. Additional diagnostic efficiency can be derived from numerical processing of optical diagnostics data providing more information compared to visual evaluation. In this paper we report on application of OCT together with numerical processing for clinical diagnostic in gynecology and otolaryngology, for monitoring of PDT in otolaryngology and on OCT and FI applications in clinical and aesthetic dermatology. Image numerical processing and quantification provides increase in diagnostic accuracy. Keywords: optical coherence tomography, fluorescence imaging, photod

  9. A Review on Homogeneous Charge Compression Ignition and Low Temperature Combustion by Optical Diagnostics

    Directory of Open Access Journals (Sweden)

    Chao Jin

    2015-01-01

    Full Text Available Optical diagnostics is an effective method to understand the physical and chemical reaction processes in homogeneous charge compression ignition (HCCI and low temperature combustion (LTC modes. Based on optical diagnostics, the true process on mixing, combustion, and emissions can be seen directly. In this paper, the mixing process by port-injection and direct-injection are reviewed firstly. Then, the combustion chemical reaction mechanism is reviewed based on chemiluminescence, natural-luminosity, and laser diagnostics. After, the evolution of pollutant emissions measured by different laser diagnostic methods is reviewed and the measured species including NO, soot, UHC, and CO. Finally, a summary and the future directions on HCCI and LTC used optical diagnostics are presented.

  10. On-line Vibration Diagnostics of the Optical Elements at BL-28 of the Photon Factory

    International Nuclear Information System (INIS)

    Maruyama, T.; Kashiwagi, T.; Kikuchi, T.; Toyoshima, A.; Kubota, M.; Ono, K.

    2007-01-01

    We have analyzed the data of encoders attached to optical elements and developed an on-line vibration diagnostics system of the monochromator. After eliminating the vibration source we have been able to improve the performance of the monochromator

  11. Transverse UV-laser irradiation-induced defects and absorption in a single-mode erbium-doped optical fiber

    International Nuclear Information System (INIS)

    Tortech, B.; Ouerdane, Y.; Boukenter, A.; Meunier, J. P.; Girard, S.; Van Uffelen, M.; Berghmans, F.; Regnier, E.; Berghmans, F.; Thienpont, H.

    2009-01-01

    Near UV-visible absorption coefficients of an erbium-doped optical fiber were investigated through an original technique based on a transverse cw UV-laser irradiation operating at 244 nm. Such irradiation leads to the generation of a quite intense guided luminescence signal in near UV spectral range. This photoluminescence probe source combined with a longitudinal translation of the fiber sample (at a constant velocity) along the UV-laser irradiation, presents several major advantages: (i) we bypass and avoid the procedures classically used to study the radiation induced attenuation which are not adapted to our case mainly because the samples present a very strong absorption with significant difficulties due to the injection of adequate UV-light levels in a small fiber diameter: (ii) the influence of the laser irradiation on the host matrix of the optical fiber is directly correlated to the evolution of the generated photoluminescence signal and (iii) in our experimental conditions, short fiber sample lengths (typically 20-30 cm) suffice to determine the associated absorption coefficients over the entire studied spectral domain. The generated photoluminescence signal is also used to characterize the absorption of the erbium ions in the same wavelength range with no cut-back method needed. (authors)

  12. Electro-optical frequency shifting of lasers for plasma diagnostics

    International Nuclear Information System (INIS)

    Forman, P.R.

    1977-07-01

    An electro-optical frequency shifting device is proposed as an aid for plasma physics heterodyne interferometry and heterodyne scattering experiments. The method has the advantage over other electro-optic shifters, that a pure separable frequency shifted beam can be obtained even when less than half wave voltage is applied. (orig.) [de

  13. Compensating the electron beam energy spread by the natural transverse gradient of laser undulator in all-optical x-ray light sources.

    Science.gov (United States)

    Zhang, Tong; Feng, Chao; Deng, Haixiao; Wang, Dong; Dai, Zhimin; Zhao, Zhentang

    2014-06-02

    All-optical ideas provide a potential to dramatically cut off the size and cost of x-ray light sources to the university-laboratory scale, with the combination of the laser-plasma accelerator and the laser undulator. However, the large longitudinal energy spread of the electron beam from laser-plasma accelerator may hinder the way to high brightness of these all-optical light sources. In this paper, the beam energy spread effect is proposed to be significantly compensated by the natural transverse gradient of a laser undulator when properly transverse-dispersing the electron beam. Theoretical analysis and numerical simulations on conventional laser-Compton scattering sources and high-gain all-optical x-ray free-electron lasers with the electron beams from laser-plasma accelerators are presented.

  14. On the CT-diagnosis of optic nerve lesions. Differential diagnostic criteria

    International Nuclear Information System (INIS)

    Unsoeld, R.

    1982-01-01

    Computed tomograms of 166 optic nerve lesions were analyzed: 97 were mainly orbital and 69 mainly intracranial. The criteria were clinical course, size, density and delineation of the optic nerve shadow, orbital and cerebral soft tissue abnormalities, and bony changes in the optic canal. Characteristic CT features are described of individual disease entities such as optic gliomas, optic nerve sheath meningiomas, neoplastic and inflammatory infiltrations. The differential diagnostic importance of individual CT criteria is evaluated and discussed. Simultaneous visualization of orbital and intracranial soft tissue changes as well as bony changes in the optic canal allow the location and identification of the majority of optic nerve lesions based on the criteria mentioned above, and optic nerve tumors can be differentiated. In 9 patients with optic neuritis due to clinically proven encephalitis and in 17 patients with total optic atrophy, no changes in the size of the optic nerve could be found. CT evaluation of the intraorbital portion of the optic nerve requires special examination techniques. Oblique computer reformations through the optic canal provide excellent visualization of bony changes in the optic canal. The exclusion of intracranial causes of optic nerve lesions requires intravenous injection of contrast material. (orig.) [de

  15. Image quality enhancement for skin cancer optical diagnostics

    Science.gov (United States)

    Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey

    2017-12-01

    The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.

  16. Neutron degradation of UV enhanced optical fibers for fusion installation plasma diagnostics

    International Nuclear Information System (INIS)

    Sporea, D.; Vata, I.; Dudu, D.; Danis, Ana

    2004-01-01

    The remote diagnostics of plasmas in fusion installations requires adequate connection links to transfer the measured signals in media subjected to high electromagnetic disturbances. We evaluated the neutron irradiation induced optical absorption in several commercially available optical fibers, as they were assessed for their possible use in fusion installations. Optical fiber samples were subjected to subsequent irradiation with fluences from 6 x 10 11 to 6 x 10 13 n/cm 2 . Significant radiation induced absorption was observed in the 220-260 nm spectral band, mainly for small core diameter optical fibers (200/220 μm), independent of the cladding material used

  17. Diagnostics of gas behind shock waves by refractive optical techniques

    International Nuclear Information System (INIS)

    Blaha, J.

    In a brief outline of optical methods for measuring neutral gas and plasma parameters, techniques are specifically dealt with based on the interferometric measurement of the refractive index. The investigation is shown of gas density changes in a shock tube using the optical Mach-Zehnder interferometer. While in a neutral gas the refractive index is determined by gas density, in a plasma the effects of all components, ie., electrons, ions and atoms are additive. The contributions to refraction from the various components may, in view of the different character and frequencies of the components, be resolved by measurement on more than one wavelength. (J.U.)

  18. Electron-Beam Produced Air Plasma: Optical and Electrical Diagnostics

    Science.gov (United States)

    Vidmar, Robert; Stalder, Kenneth; Seeley, Megan

    2006-10-01

    High energy electron impact excitation is used to stimulate optical emissions that quantify the measurement of electron beam current. A 100 keV 10-ma electron beam source is used to produce air plasma in a test cell at a pressure between 1 mTorr and 760 Torr. Optical emissions originating from the N2 2^nd positive line at 337.1 nm and the N2^+ 1^st negative line at 391.4 nm are observed. Details on calibration using signals from an isolated transmission window and a Faraday plate are discussed. Results using this technique and other electrical signal are presented.

  19. Optical design of the TMX Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Frank, A.M.

    1979-01-01

    The Thomson Scattering Diagnostic on TMX was built to measure the electron temperature in the plug. The design was based on the 2XII system built by Tom Simonen. Substantial improvements were realized over the original design, these include: (1) improved sensitivity, (2) simultaneous multiple position sampling, (3) multiple pulse capability, (4) achromatic imaging, (5) vacuum alignment capability, (6) high reliability, and (7) built in calibration and performance monitoring

  20. Lymph Node Metastases Optical Molecular Diagnostic and Radiation Therapy

    Science.gov (United States)

    2017-03-01

    Pogue CONTRACTING ORGANIZATION: Trustees of Dartmouth College Hanover, NH 03755 REPORT DATE: March 2017 TYPE OF REPORT: Annual PREPARED FOR: U.S...FORM TO THE ABOVE ADDRESS. 1. REPORT DATE March 2017 2. REPORT TYPE Annual 3. DATES COVERED 1 Mar 2016 - 28 Feb 2017 4. TITLE AND SUBTITLE Lymph...Gamma imaging of sentinel nodes is not a disease diagnostic, but rather just used to find the node and remove it for pathological inspection. As a result

  1. Fibre-Optic IR-Spectroscopy for Biomedical Diagnostics

    OpenAIRE

    Bindig, Uwe; Gersonde, Ingo; Meinke, Martina; Becker, Yukiyo; Müller, Gerhard

    2003-01-01

    The use of microscopy is a valuable means of gaining vital information for medical diagnostics. Due to a number of recent technological developments advances have been made in IR microscopy and in particular, rapid detection methods. Microscopic examination methods usually involve sampling followed by a method of sample purification or preparation. The advantages of the IR analytical method are that it is based on a direct, non‒destructive measurement of sample material and that the resulting...

  2. Peroperative optical autofluorescence biopsy-verification of its diagnostic potential

    Czech Academy of Sciences Publication Activity Database

    Ducháč, V.; Zavadil, Jiří; Vránová, J.; Jirásek, T.; Štukavec, J.; Horák, L.

    2011-01-01

    Roč. 26, č. 3 (2011), s. 325-333 ISSN 0268-8921 Institutional research plan: CEZ:AV0Z20670512 Keywords : Autofluorescence spectroscopy * Colorectal cancer * Optical fibres Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.004, year: 2011

  3. Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

    International Nuclear Information System (INIS)

    Zhu Liguo; Chen Wencong; Zhu Ximing; Pu Yikang; Li Zeren

    2009-01-01

    A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 μm is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

  4. Enhancing Brain Lesions during Acute Optic Neuritis and/or Longitudinally Extensive Transverse Myelitis May Portend a Higher Relapse Rate in Neuromyelitis Optica Spectrum Disorders.

    Science.gov (United States)

    Orman, G; Wang, K Y; Pekcevik, Y; Thompson, C B; Mealy, M; Levy, M; Izbudak, I

    2017-05-01

    Neuromyelitis optica spectrum disorders are inflammatory demyelinating disorders with optic neuritis and/or longitudinally extensive transverse myelitis episodes. We now know that neuromyelitis optica spectrum disorders are associated with antibodies to aquaporin-4, which are highly concentrated on astrocytic end-feet at the blood-brain barrier. Immune-mediated disruption of the blood-brain barrier may manifest as contrast enhancement on brain MR imaging. We aimed to delineate the extent and frequency of contrast enhancement on brain MR imaging within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and to correlate contrast enhancement with outcome measures. Brain MRIs of patients with neuromyelitis optica spectrum disorders were evaluated for patterns of contrast enhancement (periependymal, cloudlike, leptomeningeal, and so forth). The Fisher exact test was used to evaluate differences between the proportion of contrast enhancement in patients who were seropositive and seronegative for aquaporin-4 antibodies. The Mann-Whitney test was used to compare the annualized relapse rate and disease duration between patients with and without contrast enhancement and with and without seropositivity. Brain MRIs of 77 patients were evaluated; 59 patients (10 males, 49 females) were scanned within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and were included in the analysis. Forty-eight patients were seropositive, 9 were seronegative, and 2 were not tested for aquaporin-4 antibodies. Having brain contrast enhancement of any type during an acute attack was significantly associated with higher annualized relapse rates ( P = .03) and marginally associated with shorter disease duration ( P = .05). Having periependymal contrast enhancement was significantly associated with higher annualized relapse rates ( P = .03). Brain MRIs of patients with neuromyelitis optica spectrum disorders with contrast

  5. Microwave and optical diagnostics in a gadolinium plasma

    International Nuclear Information System (INIS)

    Larousse, B.

    1997-01-01

    The optimization of the separation process of the gadolinium isotopes by Ion Cyclotron Resonance requires a precise knowledge of the physical characteristics of the plasma. Thus, two kinds of diagnostics have been developed: the first one to estimate the microwave power inside the source and the second one to measure the density of atomic and ionic of the gadolinium inside the plasma source and in front of the collector. Microwave diagnostic: A microstrip antenna has been designed and developed in order to characterize the microwave at 36 GHz frequency in the plasma source. The experimental results for different plasma regimes are presented. The measurements inside the plasma source show a maximum of microwave absorption for an argon pressure of 10 -4 mb (93% of absorption of the incident wave in the conditions of isotope separation). Laser absorption diagnostic: The theory of laser absorption in presence of a magnetic field is recalled and the first results are presented. In the spectral range between 560 and 620 nm, corresponding to high energy levels of gadolinium, no signal is obtained so that the density is below the detection limit 10 10 cm -3 . In the spectral range between 380 and 400 nm, two lines are observed, issue from the fundamental and metastable (633 cm -1 ) levels. The density of metastable level of gadolinium ions is about 10 10 cm -3 with a relative precision of 15 % and its variation is studied as a function of argon pressure, at different sections of the plasma column (source, collector). The achieved set of measurements has been performed in order to check the theoretical models. (author)

  6. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Azima, Armin

    2009-07-15

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  7. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    International Nuclear Information System (INIS)

    Azima, Armin

    2009-07-01

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  8. Refractive index gradient diagnostics: analysis of different optical systems and application to COBRA ion diode

    Energy Technology Data Exchange (ETDEWEB)

    Knyazev, B A; Greenly, J B; Hammer, D A; Krastelev, E G [Cornell Univ., Ithaca, NY (United States). Laboratory of Plasma Studies; Cuneo, M E [Sandia National Laboratories, Albuquerque, NM (United States)

    1997-12-31

    Different optical system variations for refractive index gradient diagnostics with a laser beam probe have been analyzed. A `three-telescope` optical system which permits simultaneous measurement of both the laser beam centroid deflection by a bi-cell photodiode and the spatial Fourier spectrum of the deflected beam by a streak camera has been implemented on the COBRA ion diode. The dynamics of the anode plasma layer was studied with these techniques. (author). 3 figs., 8 refs.

  9. Optical remote diagnostics of atmospheric propagating beams of ionizing radiation

    Science.gov (United States)

    Karl JR., Robert R.

    1990-03-06

    Data is obtained for use in diagnosing the characteristics of a beam of ionizing radiation, such as charged particle beams, neutral particle beams, and gamma ray beams. In one embodiment the beam is emitted through the atmosphere and produces nitrogen fluorescence during passage through air. The nitrogen fluorescence is detected along the beam path to provide an intensity from which various beam characteristics can be calculated from known tabulations. Optical detecting equipment is preferably located orthogonal to the beam path at a distance effective to include the entire beam path in the equipment field of view.

  10. Optically pumped FIR lasers and their application in plasma diagnostics

    International Nuclear Information System (INIS)

    Bakos, J.S.

    1986-06-01

    The pysics and the construction of the far infrared lasers (FIRL) and of the infrared lasers pumping them are reviewed. The details of the construction, resonating and pumping systems, spectral and power characteristics of the FIRLs are discussed. Recently more than 1000 laser lines are known and used in the 27-80 mm wavelength range, but in many cases the laser kinetics are not fully understood, and some instability phenomena cannot be prevented. New nonlinear processes were found: two-photon pumping, hyper Raman laser tuning and relaxation phenomena. A broad application field, the plasma diagnostics by far infrared lasers is described. Scattering of infrared laser radiation can give new interesting information on the not understood effect of the anomalous transport in the high temperature plasma. (D.Gy.)

  11. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  12. Novel Readout Method for Molecular Diagnostic Assays Based on Optical Measurements of Magnetic Nanobead Dynamics

    DEFF Research Database (Denmark)

    Donolato, Marco; Antunes, Paula Soares Martins; Bejhed, Rebecca S.

    2015-01-01

    behavior. We prove that the optical transmission spectra are highly sensitive to the formation of permanent MNB clusters and, thereby to the target analyte concentration. As a specific clinically relevant diagnostic case, we detect DNA coils formed via padlock probe recognition and isothermal rolling...

  13. Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

    DEFF Research Database (Denmark)

    Moseev, D.; Meo, Fernando; Korsholm, Søren Bang

    2012-01-01

    require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic...

  14. A multichannel smartphone optical biosensor for high-throughput point-of-care diagnostics.

    Science.gov (United States)

    Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei

    2017-01-15

    Current reported smartphone spectrometers are only used to monitor or measure one sample at a time. For the first time, we demonstrate a multichannel smartphone spectrometer (MSS) as an optical biosensor that can simultaneously optical sense multiple samples. In this work, we developed a novel method to achieve the multichannel optical spectral sensing with nanometer resolution on a smartphone. A 3D printed cradle held the smartphone integrated with optical components. This optical sensor performed accurate and reliable spectral measurements by optical intensity changes at specific wavelength or optical spectral shifts. A custom smartphone multi-view App was developed to control the optical sensing parameters and to align each sample to the corresponding channel. The captured images were converted to the transmission spectra in the visible wavelength range from 400nm to 700nm with the high resolution of 0.2521nm per pixel. We validated the performance of this MSS via measuring the concentrations of protein and immunoassaying a type of human cancer biomarker. Compared to the standard laboratory instrument, the results sufficiently showed that this MSS can achieve the comparative analysis detection limits, accuracy and sensitivity. We envision that this multichannel smartphone optical biosensor will be useful in high-throughput point-of-care diagnostics with its minimizing size, light weight, low cost and data transmission function. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Thermal diagnostic of the optical window on board LISA Pathfinder

    International Nuclear Information System (INIS)

    Nofrarias, M; MarIn, A F GarcIa; Lobo, A; Heinzel, G; Ramos-Castro, J; Sanjuan, J; Danzmann, K

    2007-01-01

    Vacuum conditions inside the LTP gravitational reference sensor must be under 10 -5 Pa, a rather demanding requirement. The optical window (OW) is an interface which seals the vacuum enclosure and, at the same time, lets the laser beam go through for interferometric metrology with the test masses. The OW is a plane-parallel plate clamped in a titanium flange, and is considerably sensitive to thermal and stress fluctuations. It is critical for the required precision measurements, hence its temperature will be carefully monitored in flight. This paper reports on the results of a series of OW characterization laboratory runs, intended to study its response to selected thermal signals, as well as their fit to numerical models, and the meaning of the latter. We find that a single-pole ARMA transfer function provides a consistent approximation to the OW response to thermal excitations, and derive a relationship with the physical processes taking place in the OW. We also show how the system noise reduction can be accomplished by means of that transfer function

  16. Design considerations for highly effective fluorescence excitation and detection optical systems for molecular diagnostics

    Science.gov (United States)

    Kasper, Axel; Van Hille, Herbert; Kuk, Sola

    2018-02-01

    Modern instruments for molecular diagnostics are continuously optimized for diagnostic accuracy, versatility and throughput. The latest progress in LED technology together with tailored optics solutions allows developing highly efficient photonics engines perfectly adapted to the sample under test. Super-bright chip-on-board LED light sources are a key component for such instruments providing maximum luminous intensities in a multitude of narrow spectral bands. In particular the combination of white LEDs with other narrow band LEDs allows achieving optimum efficiency outperforming traditional Xenon light sources in terms of energy consumption, heat dissipation in the system, and switching time between spectral channels. Maximum sensitivity of the diagnostic system can only be achieved with an optimized optics system for the illumination and imaging of the sample. The illumination beam path must be designed for optimum homogeneity across the field while precisely limiting the angular distribution of the excitation light. This is a necessity for avoiding spill-over to the detection beam path and guaranteeing the efficiency of the spectral filtering. The imaging optics must combine high spatial resolution, high light collection efficiency and optimized suppression of excitation light for good signal-to-noise ratio. In order to achieve minimum cross-talk between individual wells in the sample, the optics design must also consider the generation of stray light and the formation of ghost images. We discuss what parameters and limitations have to be considered in an integrated system design approach covering the full path from the light source to the detector.

  17. Hypereosinophilic Atopic Transverse Myelitis

    African Journals Online (AJOL)

    2018-06-11

    4 days ago ... Atopic transverse myelitis is a rare disorder that is defined as a ... was commenced on prednisolone and had good response to treatment. .... Atopic myelitis is more common in male sex such as .... their identity, but anonymity cannot be guaranteed. ... useful diagnostic clue in surgical neuropathology.

  18. Handbook of coherent domain optical methods biomedical diagnostics, environmental and material science

    CERN Document Server

    2004-01-01

    For the first time in one set of books, coherent-domain optical methods are discussed in the framework of various applications, which are characterized by a strong light scattering. A few chapters describe basic research containing the updated results on coherent and polarized light non-destructive interactions with a scattering medium, in particular, diffraction, interference, and speckle formation at multiple scattering. These chapters allow for understanding coherent-domain diagnostic techniques presented in later chapters. A large portion of Volume I is dedicated to analysis of various aspects of optical coherence tomography (OCT) - a very new and growing field of coherent optics. Two chapters on laser scanning confocal microscopy give insight to recent extraordinary results on in vivo imaging and compare the possibilities and achievements of confocol, excitation multiphoton, and OCT microscopy. This two volume reference contains descriptions of holography, interferometry and optical heterodyning techniqu...

  19. Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

    International Nuclear Information System (INIS)

    Frayer, Daniel K.; Johnson, Douglas; Ekdahl, Carl

    2010-01-01

    An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

  20. Gaseous laser targets and optical diagnostics for studying compressible hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Edwards, J M; Robey, H; Mackinnon, A

    2001-01-01

    Explore the combination of optical diagnostics and gaseous targets to obtain important information about compressible turbulent flows that cannot be derived from traditional laser experiments for the purposes of V and V of hydrodynamics models and understanding scaling. First year objectives: Develop and characterize blast wave-gas jet test bed; Perform single pulse shadowgraphy of blast wave interaction with turbulent gas jet as a function of blast wave Mach number; Explore double pulse shadowgraphy and image correlation for extracting velocity spectra in the shock-turbulent flow interaction; and Explore the use/adaptation of advanced diagnostics

  1. Diagnostic value of optical coherence tomography for intracranial pressure in idiopathic intracranial hypertension

    DEFF Research Database (Denmark)

    Skau, M; Yri, H; Sander, B

    2013-01-01

    BACKGROUND: Idiopathic intracranial hypertension (IIH) is a condition of raised intracranial pressure (ICP) in the absence of space-occupying lesions or other known etiology. It primarily affects young obese females, and potentially causes permanent visual loss due to papilledema and secondary...... optic atrophy. The aim of this study was to evaluate the diagnostic value of optical coherence tomography (OCT) as a marker for CSF opening pressure in patients with idiopathic intracranial hypertension (IIH). METHODS: We conducted a case-control study of 20 newly diagnosed, 21 long-term IIH patients...

  2. Irradiation tests of radiation resistance optical fibers for fusion diagnostic application

    Science.gov (United States)

    Kakuta, Tsunemi; Shikama, Tatsuo; Nishitani, Takeo; Yamamoto, Shin; Nagata, Shinji; Tsuchiya, Bun; Toh, Kentaro; Hori, Junichi

    2002-11-01

    To promote development of radiation-resistant core optical fibers, the ITER-EDA (International Thermonuclear Experimental Reactor-Engineering Design Activity) recommended carrying out international round-robin irradiation tests of optical fibers to establish a reliable database for their applications in the ITER plasma diagnostics. Ten developed optical fibers were irradiation-tested in a Co-60 gamma cell, a Japan Materials Testing Reactor (JMTR). Also, some of them were irradiation tested in a fast neutron irradiation facility of FNS (Fast Neutron Source), especially to study temperature dependence of neutron-associated irradiation effects. Included were several Japanese fluorine doped fibers and one Japanese standard fiber (purified and undoped silica core), as well as seven Russian fibers. Some of Russian fibers were drawn by Japanese manufactures from Russian made pre-form rods to study effects of manufacturing processes to radiation resistant properties. The present paper will describe behaviors of growth of radiation-induced optical transmission loss in the wavelength range of 350-1750nm. Results indicate that role of displacement damages by fast neutrons are very important in introducing permanent optical transmission loss. Spectra of optical transmission loss in visible range will depend on irradiation temperatures and material parameters of optical fibers.

  3. Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

    Science.gov (United States)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.

    2004-01-01

    Over the past decade advanced optical diagnostic techniques have evolved and matured to a point where they are now widely applied in the interrogation of high pressure combusting flows. At NASA Glenn Research Center (GRC), imaging techniques have been used successfully in on-going work to develop the next generation of commercial aircraft gas turbine combustors. This work has centered on providing a means by which researchers and designers can obtain direct visual observation and measurements of the fuel injection/mixing/combustion processes and combustor flowfield in two- and three-dimensional views at actual operational conditions. Obtaining a thorough understanding of the chemical and physical processes at the extreme operating conditions of the next generation of combustors is critical to reducing emissions and increasing fuel efficiency. To accomplish this and other tasks, the diagnostic team at GRC has designed and constructed optically accessible, high pressurer high temperature flame tubes and sectar rigs capable of optically probing the 20-60 atm flowfields of these aero-combustors. Among the techniques employed at GRC are planar laser-induced fluorescence (PLIF) for imaging molecular species as well as liquid and gaseous fuel; planar light scattering (PLS) for imaging fuel sprays and droplets; and spontaneous Raman scattering for species and temperature measurement. Using these techniques, optical measurements never before possible have been made in the actual environments of liquid fueled gas turbines. 2-D mapping of such parameters as species (e.g. OH-, NO and kerosene-based jet fuel) distribution, injector spray angle, and fuel/air distribution are just some of the measurements that are now routinely made. Optical imaging has also provided prompt feedback to researchers regarding the effects of changes in the fuel injector configuration on both combustor performance and flowfield character. Several injector design modifications and improvements have

  4. HAIFA: A modular, fiber-optic coupled, spectroscopic diagnostic for plasmas

    International Nuclear Information System (INIS)

    Ramsey, A.T.; Turner, S.L.

    1987-01-01

    HAIFA is a modular, multichannel, fiber optically coupled spectroscopy diagnostic for tokamak plasmas. It operates in the visible, measuring H/sub α/ radiation, the visible continuum from thermal bremsstrahlung, and selected impurity lines. HAIFA is characterized by high modularity and flexibility, good radiation resistance, high noise immunity, and low cost. Details of design, construction, and calibration are given. The analysis of visible bremsstrahlung radiation measurements to deduce the effective ionic charge in a plasma is discussed

  5. Optical biosensor technologies for molecular diagnostics at the point-of-care

    Science.gov (United States)

    Schotter, Joerg; Schrittwieser, Stefan; Muellner, Paul; Melnik, Eva; Hainberger, Rainer; Koppitsch, Guenther; Schrank, Franz; Soulantika, Katerina; Lentijo-Mozo, Sergio; Pelaz, Beatriz; Parak, Wolfgang; Ludwig, Frank; Dieckhoff, Jan

    2015-05-01

    Label-free optical schemes for molecular biosensing hold a strong promise for point-of-care applications in medical research and diagnostics. Apart from diagnostic requirements in terms of sensitivity, specificity, and multiplexing capability, also other aspects such as ease of use and manufacturability have to be considered in order to pave the way to a practical implementation. We present integrated optical waveguide as well as magnetic nanoparticle based molecular biosensor concepts that address these aspects. The integrated optical waveguide devices are based on low-loss photonic wires made of silicon nitride deposited by a CMOS compatible plasma-enhanced chemical vapor deposition (PECVD) process that allows for backend integration of waveguides on optoelectronic CMOS chips. The molecular detection principle relies on evanescent wave sensing in the 0.85 μm wavelength regime by means of Mach-Zehnder interferometers, which enables on-chip integration of silicon photodiodes and, thus, the realization of system-on-chip solutions. Our nanoparticle-based approach is based on optical observation of the dynamic response of functionalized magneticcore/ noble-metal-shell nanorods (`nanoprobes') to an externally applied time-varying magnetic field. As target molecules specifically bind to the surface of the nanoprobes, the observed dynamics of the nanoprobes changes, and the concentration of target molecules in the sample solution can be quantified. This approach is suitable for dynamic real-time measurements and only requires minimal sample preparation, thus presenting a highly promising point-of-care diagnostic system. In this paper, we present a prototype of a diagnostic device suitable for highly automated sample analysis by our nanoparticle-based approach.

  6. Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

    International Nuclear Information System (INIS)

    Ko, Jinseok; Scott, Steve; Bitter, Manfred; Lerner, Scott

    2009-01-01

    The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

  7. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ross, J. S., E-mail: ross36@llnl.gov; Datte, P.; Divol, L.; Galbraith, J.; Hatch, B.; Landen, O.; Manuel, A. M.; Molander, W.; Moody, J. D.; Swadling, G. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Froula, D. H.; Katz, J. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Kilkenny, J. [General Atomics, San Diego, California 92186 (United States); Montgomery, D. S. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Weaver, J. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-11-15

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

  8. Electron charge and spin delocalization revealed in the optically probed longitudinal and transverse spin dynamics in n -GaAs

    Science.gov (United States)

    Belykh, V. V.; Kavokin, K. V.; Yakovlev, D. R.; Bayer, M.

    2017-12-01

    The evolution of the electron spin dynamics as consequence of carrier delocalization in n -type GaAs is investigated by the recently developed extended pump-probe Kerr/Faraday rotation spectroscopy. We find that isolated electrons localized on donors demonstrate a prominent difference between the longitudinal and transverse spin relaxation rates in a magnetic field, which is almost absent in the metallic phase. The inhomogeneous transverse dephasing time T2* of the spin ensemble strongly increases upon electron delocalization as a result of motional narrowing that can be induced by increasing either the donor concentration or the temperature. An unexpected relation between T2* and the longitudinal spin relaxation time T1 is found, namely, that their product is about constant, as explained by the magnetic field effect on the spin diffusion. We observe a two-stage longitudinal spin relaxation, which suggests the establishment of spin temperature in the system of exchange-coupled donor-bound electrons.

  9. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  10. Optical diagnostics of tumour cells at different stages of pathology development

    Energy Technology Data Exchange (ETDEWEB)

    Shcheglova, L S; Maryakhina, V S [Orenburg State University, Orenburg (Russian Federation); Abramova, L L [Orenburg State Agrarian University, Orenburg (Russian Federation)

    2013-11-30

    The differences in optical and biophysical properties between the cells of mammary gland tumour extracted from tumours of different diameter are described. It is shown that the spectral and spectrokinetic properties of fluorescent probes in the cells extracted from the tumours 1 – 3 cm in diameter are essentially different. Thus, the extinction coefficient of rhodamine 6G gradually increases with the pathology development. At the same time the rate of interaction of the triplet states of molecular probes with the oxygen, diluted in the tumour cells cytoplasm, decreases with the growth of the tumour capsule diameter. The observed regularities can be due to the changes in the cell structure, biochemical and biophysical properties. The reported data may be useful for developing optical methods of diagnostics of biotissue pathological conditions. (optical methods in biology and medicine)

  11. Additive diagnostic role of imaging in glaucoma: optical coherence tomography and retinal nerve fiber layer photography.

    Science.gov (United States)

    Kim, Ko Eun; Kim, Seok Hwan; Oh, Sohee; Jeoung, Jin Wook; Suh, Min Hee; Seo, Je Hyun; Kim, Martha; Park, Ki Ho; Kim, Dong Myung

    2014-11-20

    To investigate the additive diagnostic role of spectral-domain optical coherence tomography (SD-OCT) and red-free retinal nerve fiber layer photography (RNFLP) in making clinical glaucoma diagnosis. Four diagnostic combination sets, including the most recent image from each measurement of 196 glaucoma eyes (including the 44 preperimetric glaucoma eyes) and 101 healthy eyes, were prepared: (1) stereo disc photography and Humphrey visual field (SH), (2) SH and SD-OCT (SHO), (3) SH and RNFLP (SHR), and (4) SHR and SD-OCT (SHRO). Each randomly sorted set was serially presented at 1-month intervals to five glaucoma specialists who were asked to evaluate them in a subjective and independent manner. The specialists' glaucoma-diagnostic performances based on the sets were then compared. For each specialist, adding SD-OCT to SH or SHR increased the glaucoma-diagnostic sensitivity but not to a level of statistical significance. For one specialist, adding RNFLP to SH significantly increased the sensitivity. Each specialist showed a high level of specificity regardless of the diagnostic set. The overall sensitivity of all specialists' assessments was significantly increased by adding RNFLP or the combination of SD-OCT and RNFLP to SH (P < 0.001); however, adding SD-OCT to SH or SHR did not significantly increase the sensitivity. A similar relationship was noted also for the preperimetric glaucoma subgroup. In contrast to RNFLP, SD-OCT did not significantly enhance the diagnostic accuracy of detecting glaucoma or even of preperimetric glaucoma. Our results suggest that, at least for glaucoma specialists, the additive diagnostic role of OCT is limited. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  12. Glaucoma Diagnostic Ability of the Optical Coherence Tomography Angiography Vessel Density Parameters.

    Science.gov (United States)

    Chung, Jae Keun; Hwang, Young Hoon; Wi, Jae Min; Kim, Mijin; Jung, Jong Jin

    2017-11-01

    To investigate the glaucoma diagnostic abilities of vessel density parameters as determined by optical coherence tomography (OCT) angiography in different stages of glaucoma. A total of 113 healthy eyes and 140 glaucomatous eyes were enrolled. Diagnostic abilities of the OCT vessel density parameters in the optic nerve head (ONH), peripapillary, and macular regions were evaluated by calculating the area under the receiver operation characteristic curves (AUCs). AUCs of the peripapillary vessel density parameters and circumpapillary retinal nerve fiber layer (RNFL) thickness were compared. OCT angiography vessel densities in the ONH, peripapillary, and macular regions in the glaucomatous eyes were significantly lower than those in the healthy eyes (P glaucoma detection. The peripapillary vessel density parameters showed similar AUCs with the corresponding sectoral RNFL thickness (P > 0.05). However, in the early stage of glaucoma, the AUCs of the inferotemporal and temporal peripapillary vessel densities were significantly lower than that of the RNFL thickness (P glaucoma diagnostic ability with circumpapillary RNFL thickness, in the early stage, the vessel density parameters showed limited clinical value.

  13. A Novel Optical Diagnostic for In Situ Measurements of Lithium Polysulfides in Battery Electrolytes.

    Science.gov (United States)

    Saqib, Najmus; Silva, Cody J; Maupin, C Mark; Porter, Jason M

    2017-07-01

    An optical diagnostic technique to determine the order and concentration of lithium polysulfides in lithium-sulfur (Li-S) battery electrolytes has been developed. One of the major challenges of lithium-sulfur batteries is the problem of polysulfide shuttling between the electrodes, which leads to self-discharge and loss of active material. Here we present an optical diagnostic for quantitative in situ measurements of lithium polysulfides using attenuated total reflection Fourier transform infrared (FT-IR) spectroscopy. Simulated infrared spectra of lithium polysulfide molecules were generated using computational quantum chemistry routines implemented in Gaussian 09. The theoretical spectra served as a starting point for experimental characterization of lithium polysulfide solutions synthesized by the direct reaction of lithium sulfide and sulfur. Attenuated total reflection FT-IR spectroscopy was used to measure absorption spectra. The lower limit of detection with this technique is 0.05 M. Measured spectra revealed trends with respect to polysulfide order and concentration, consistent with theoretical predictions, which were used to develop a set of equations relating the order and concentration of lithium polysulfides in a sample to the position and area of a characteristic infrared absorption band. The diagnostic routine can measure the order and concentration to within 5% and 0.1 M, respectively.

  14. Proposal to develop techniques using magneto-optic and electro-optic effects in optical fiber for CTR diagnostics

    International Nuclear Information System (INIS)

    Chandler, G.I.; Jahoda, F.C.

    1982-02-01

    We discuss the developing technology of measuring electric and magnetic fields with optical fibers using the Faraday and Kerr effects, magnetostriction, and Sagnac interferometry. We review the measurement of induced birefringence in the presence of natural birefringence. We propose the use of these effects in making measurements in the fusion research program, with ZT-40 as an example

  15. Reliability assessment of fiber optic communication lines depending on external factors and diagnostic errors

    Science.gov (United States)

    Bogachkov, I. V.; Lutchenko, S. S.

    2018-05-01

    The article deals with the method for the assessment of the fiber optic communication lines (FOCL) reliability taking into account the effect of the optical fiber tension, the temperature influence and the built-in diagnostic equipment errors of the first kind. The reliability is assessed in terms of the availability factor using the theory of Markov chains and probabilistic mathematical modeling. To obtain a mathematical model, the following steps are performed: the FOCL state is defined and validated; the state graph and system transitions are described; the system transition of states that occur at a certain point is specified; the real and the observed time of system presence in the considered states are identified. According to the permissible value of the availability factor, it is possible to determine the limiting frequency of FOCL maintenance.

  16. Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Rowan, W. L., E-mail: w.l.rowan@austin.utexas.edu; Houshmandyar, S.; Phillips, P. E.; Austin, M. E. [Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712 (United States); Beno, J. H.; Ouroua, A. [Center for Electromechanics, The University of Texas at Austin, Austin, Texas 78712 (United States); Hubbard, A. E. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Khodak, A.; Taylor, G. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-11-15

    Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

  17. Single-shot electro-optic experiments for electron bunch diagnostics at Tsinghua Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Du, Yingchao; Yan, Lixin; Hua, Jianfei; Zhang, Zhen; Zhou, Zheng [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Huang, Wenhui, E-mail: huangwh@mail.tsinghua.edu.cn [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Tang, Chuanxiang [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Li, Ming [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-10-21

    The electro-optic (EO) technique detects the Coulomb electric field distribution of relativistic electron bunches to obtain the associated longitudinal profile. This diagnostic method allows the direct time-resolved single-shot measurement and thus the real-time monitoring of the bunch profile and beam arrival time in a non-destructive way with sub-picosecond temporal resolution. In this paper, we report the measurement of the longitudinal profile of an electron bunch through electro-optic spectral decoding detection, in which the bunch profile is encoded into the spectra of the linearly chirped laser pulse. The experimental setup and measurement results of a 40 MeV electron bunch are presented, with a temporal profile length of 527 fs rms (~1.24 ps FWHM) and a beam arrival time jitter of 471 fs rms. Temporal resolution and future experimental improvement are also discussed.

  18. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  19. Transverse stress induced LP 02-LP 21 modal interference of stimulated Raman scattered light in a few-mode optical fiber

    Science.gov (United States)

    Sharma, A.; Posey, R.

    1996-02-01

    Four-photon mixing followed by stimulated Raman scattering is observed in LP 02 mode in a 7.9 μm core diameter optical fiber. A localized transverse stress efficiency couples LP 02 to the LP 21 mode with a macroscopic beat length of 1.8 mm. LP 02-LP 21 modal interference is investigated by detecting the 550-590 nm SRS through a pinhole in the far field exit plane. Quantitative explanation of wavelength dependent intensity modulation results in a precise experimental determination of {∂[β 02(λ) - β 21(λ)] }/{∂λ}, for mode-propagation constants β02( λ) and β21( λ) of LP 02 and LP 21 modes respectively, as well as Δ, the relative core-cladding refractive index difference. The LP 02-LP 21 modal interference is used for sensing of temperature between 50-300°C.

  20. Diagnostic accuracy of optical coherence tomography in actinic keratosis and basal cell carcinoma.

    Science.gov (United States)

    Olsen, J; Themstrup, L; De Carvalho, N; Mogensen, M; Pellacani, G; Jemec, G B E

    2016-12-01

    Early diagnosis of non-melanoma skin cancer (NMSC) is potentially possible using optical coherence tomography (OCT) which provides non-invasive, real-time images of skin with micrometre resolution and an imaging depth of up to 2mm. OCT technology for skin imaging has undergone significant developments, improving image quality substantially. The diagnostic accuracy of any method is influenced by continuous technological development making it necessary to regularly re-evaluate methods. The objective of this study is to estimate the diagnostic accuracy of OCT in basal cell carcinomas (BCC) and actinic keratosis (AK) as well as differentiating these lesions from normal skin. A study set consisting of 142 OCT images meeting selection criterea for image quality and diagnosis of AK, BCC and normal skin was presented uniformly to two groups of blinded observers: 5 dermatologists experienced in OCT-image interpretation and 5 dermatologists with no experience in OCT. During the presentation of the study set the observers filled out a standardized questionnaire regarding the OCT diagnosis. Images were captured using a commercially available OCT machine (Vivosight ® , Michelson Diagnostics, UK). Skilled OCT observers were able to diagnose BCC lesions with a sensitivity of 86% to 95% and a specificity of 81% to 98%. Skilled observers with at least one year of OCT-experience showed an overall higher diagnostic accuracy compared to inexperienced observers. The study shows an improved diagnostic accuracy of OCT in differentiating AK and BCC from healthy skin using state-of-the-art technology compared to earlier OCT technology, especially concerning BCC diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Novel non-intercepting diagnostic techniques for low-emittance relativistic electron beams

    International Nuclear Information System (INIS)

    Moran, M.J.; Chang, B.

    1988-01-01

    Relativistic electron beams are being generated with emittances low enough that diffraction radiation can be used for beam diagnostics. Techniques based on diffraction radiation can be used to measure the beam transverse momentum distribution and to measure the transverse spatial distribution. The radiation is intense and can be in the visible spectral region where optical diagnostic techniques can be used to maximum advantage. 4 refs. 3 figs

  2. Optical diagnostic of breast cancer using Raman, polarimetric and fluorescence spectroscopy

    Science.gov (United States)

    Anwar, Shahzad; Firdous, Shamaraz; Rehman, Aziz-ul; Nawaz, Muhammed

    2015-04-01

    We presented the optical diagnostic of normal and cancerous human breast tissues using Raman, polarimetric and fluorescence spectroscopic techniques. Breast cancer is the second leading cause of cancer death among women worldwide. Optical diagnostics of cancer offered early intervention and the greatest chance of cure. Spectroscopic data were collected from freshly excised surgical specimens of normal tissues with Raman bands at 800, 1171 and 1530 cm-1 arising mainly by lipids, nucleic acids, proteins, carbohydrates and amino acids. For breast cancer, Raman bands are observed at 1070, 1211, 1495, 1583 and 1650 cm-1. Results demonstrate that the spectra of normal tissue are dominated by lipids and amino acids. Polarization decomposition of the Mueller matrix and confocal microscopic fluorescence provides detailed description of cancerous tissue and distinguishes between the normal and malignant one. Based on these findings, we successfully differentiate normal and malignant breast tissues at an early stage of disease. There is a need to develop a new tool for noninvasive, real-time diagnosis of tissue abnormalities and a test procedure for detecting breast cancer at an early stage.

  3. Optical diagnostics of lead and PbGa2S4 layered crystal laser plasmas

    International Nuclear Information System (INIS)

    Shuaibov, A.K.; Dashchenko, A.I.; Shevera, I.V.

    2001-01-01

    Laser plasmas produced at the surfaces of lead and a PbGa 2 S 4 layered crystal irradiated by a neodymium laser with λ = 1.06 μm, pulse duration τ = 20 ns, and intensity W = (1-2) x 10 9 W/cm 2 are studied using optical diagnostics. It is shown that, in a lead plasma, the most intense (characteristic) lines are the PbI 405.7-nm, PbI 368.3-nm, PbI 364-nm, and PbII 220.4-nm lines. In a layered crystal plasma, the emission spectrum is an aggregation of the most intense PbI and GaI lines, whereas sulfur lines are absent. The bottlenecks of the recombination of the ionic and atomic components of the lead and PbGa 2 S 4 crystal plasmas are determined. The average propagation velocity of the lead laser plume is 18-20 km/s. A comparative analysis of the emission dynamics of PbI and GaI lines in the laser plasmas of these metals and in the plasma of a PbGa 2 S 4 crystal is carried out. The results obtained are important for the optical diagnostics of the plasmas of lead- and gallium-containing crystals and for the optimization of laser deposition of the thin films of these substances

  4. Diagnostics of helium plasma by collisional-radiative modeling and optical emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wonwook; Kwon, Duck-Hee [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    Optical diagnostics for the electron temperature (T{sub e}) and the electron density (n{sub e}) of fusion plasma is important for understanding and controlling the edge and the divertor plasmas in tokamak. Since the line intensity ratio method using the collisional-radiative modeling and OES (optical emission spectroscopy) is simple and does not disturb the plasma, many fusion devices with TEXTOR, JET, JT-60U, LHD, and so on, have employed the line intensity ratio method as a basic diagnostic tool for neutral helium (He I). The accuracy of the line intensity ratio method depends on the reliability of the cross sections and rate coefficients. We performed state-of-the-art R-matrix calculations including couplings up to n=7 states and the distorted wave (DW) calculations for the electron-impact excitation (EIE) cross sections of He I using the flexible atomic code (FAC). The collisional-radiative model for He I was constructed using the calculated the cross sections. The helium collisional-radiative model for He I was constructed to diagnose the electron temperature and the electron density of the plasma. The electron temperature and density were determined by using the line intensity ratio method.

  5. Assessment of diagnostic multileaf collimator for cephalometric exposure reduction using optically stimulated luminescent dosemeters

    International Nuclear Information System (INIS)

    Han, Su Chul; Kim, Kum Bae; Jung, Haijo; Ji, YoungHoon; Park, Seungwoo

    2017-01-01

    A diagnostic multileaf collimator (MLC) was developed for diagnostic radiography dose reduction. Optically stimulated luminescent dosemeters (OSLDs) were used to evaluate the efficacy of this device for dental radiography cephalometric exposure reduction. The OSLD dosimetric characteristics for 80 kVp cephalometric exposure were first obtained. The batch homogeneity and reproducibility were 1.67 % and 0.18-1.58, respectively. Good linearity was obtained between the OSLD dose and response, and the angular dependence was within ±4 %. The equivalent organ doses for the left eye, right eye and thyroid were 41.20±6.58, 178.86±1.71 and 171.12±8.78 mSv and 36.80±0.33, 156.63±0.22 and 22.04±0.13 mSv for the open and MLC fields, respectively. The MLC-induced dose reductions for the left and right eyes of in field were 10.67±16.78 and 12.42±8.84 %, respectively, and that of the thyroid gland of out of field was 87±8.82 %, considering combined uncertainty. Therefore, use of diagnostic MLC for dose reduction during dental radiography cephalometric exposure is both feasible and effective. (authors)

  6. Real-time optical diagnostics of graphene growth induced by pulsed chemical vapor deposition

    Science.gov (United States)

    Puretzky, Alexander A.; Geohegan, David B.; Pannala, Sreekanth; Rouleau, Christopher M.; Regmi, Murari; Thonnard, Norbert; Eres, Gyula

    2013-06-01

    The kinetics and mechanisms of graphene growth on Ni films at 720-880 °C have been measured using fast pulses of acetylene and real-time optical diagnostics. In situ UV-Raman spectroscopy was used to unambiguously detect isothermal graphene growth at high temperatures, measure the growth kinetics with ~1 s temporal resolution, and estimate the fractional precipitation upon cooldown. Optical reflectivity and videography provided much faster temporal resolution. Both the growth kinetics and the fractional isothermal precipitation were found to be governed by the C2H2 partial pressure in the CVD pulse for a given film thickness and temperature, with up to ~94% of graphene growth occurring isothermally within 1 second at 800 °C at high partial pressures. At lower partial pressures, isothermal graphene growth is shown to continue 10 seconds after the gas pulse. These flux-dependent growth kinetics are described in the context of a dissolution/precipitation model, where carbon rapidly dissolves into the Ni film and later precipitates driven by gradients in the chemical potential. The combination of pulsed-CVD and real-time optical diagnostics opens new opportunities to understand and control the fast, sub-second growth of graphene on various substrates at high temperatures.The kinetics and mechanisms of graphene growth on Ni films at 720-880 °C have been measured using fast pulses of acetylene and real-time optical diagnostics. In situ UV-Raman spectroscopy was used to unambiguously detect isothermal graphene growth at high temperatures, measure the growth kinetics with ~1 s temporal resolution, and estimate the fractional precipitation upon cooldown. Optical reflectivity and videography provided much faster temporal resolution. Both the growth kinetics and the fractional isothermal precipitation were found to be governed by the C2H2 partial pressure in the CVD pulse for a given film thickness and temperature, with up to ~94% of graphene growth occurring isothermally

  7. Transverse effects in UV FELs

    International Nuclear Information System (INIS)

    Small, D.W.; Wong, R.K.; Colson, W.B.

    1995-01-01

    In an ultraviolet Free Electron Laser (UV FEL), the electron beam size can be approximately the same as the optical mode size. The performance of a UV FEL is studied including the effect of emittance, betatron focusing, and external focusing of the electron beam on the transverse optical mode. The results are applied to the Industrial Laser Consortium's UV FEL

  8. Optic Neuropathy Secondary to Polyarteritis Nodosa, Case Report, and Diagnostic Challenges.

    Science.gov (United States)

    Vazquez-Romo, Kristian A; Rodriguez-Hernandez, Adrian; Paczka, Jose A; Nuño-Suarez, Moises A; Rocha-Muñoz, Alberto D; Zavala-Cerna, Maria G

    2017-01-01

    To describe a case of optic neuropathy as a primary manifestation of polyarteritis nodosa (PAN) and discuss diagnostic challenges. Case report. A 41-year-old Hispanic man presented with a 2-day history of reduced visual acuity in his left eye. Physical examination revealed a complete visual field loss in the affected eye. Best-corrected visual acuity (BCVA) in the left eye was hand motion, and fundus examination revealed a hyperemic optic disk with blurred margins, swelling, retinal folds, dilated veins, and normal size arteries. BCVA in the right eye was 20/20; no anomalies were seen during examination of the fundus. The patient was started on oral corticosteroids and once the diagnosis of PAN was made, cyclophosphamide was added to the treatment regimen. Six months later, the patient recovered his BCVA to 20/20 in his left eye. Rarely does optic neuropathy present as a primary manifestation of PAN; nevertheless, it represents an ophthalmologic emergency that requires expeditious anti-inflammatory and immunosuppressive treatment to decrease the probability of permanent visual damage. Unfortunately, diagnosing PAN is challenging as it necessitates a high index of suspicion. In young male patients who present for the first time with diminished visual acuity, ophthalmologists become cornerstones in the suspicion of this diagnosis and should be responsible for continuing the study until a diagnosis is reached to ensure rapid commencement of immunosuppressive treatment.

  9. The general optics structure of millimeter-wave imaging diagnostic on TOKAMAK

    International Nuclear Information System (INIS)

    Zhu, Y.; Xie, J.; Liu, W.D.; Luo, C.; Zhao, Z.; Chen, D.; Domier, C.W.; Luhmann, N.C. Jr.; Chen, M.; Hu, X.

    2016-01-01

    Advanced imaging optics techniques have significantly improved the performance of millimeter-wave imaging diagnostics, such as Electron Cyclotron Emission imaging and Microwave Imaging of Reflectometry. The fundamental functions of millimeter-wave imaging optics are focusing, collecting the emission or reflected microwave signal from the target area in the plasma and focusing the emitted (reflected) signal on the detector array. The location of the observation area can be changed using the focus lens. Another important function of the imaging optics is zooming. The size of the observation area in poloidal direction can be adjusted by the zoom lenses and the poloidal spatial resolution is determined by the level of zoom. The field curvature adjustment lenses are employed to adjust the shape of the image plane in the poloidal direction to reduce crosstalk between neighboring channels. The incident angle on each channel is controlled using the specific surface type of the front-side lenses to increase the signal-to-noise ratio. All functions are decoupled with the minimum number of lenses. Successful applications are given

  10. Novel readout method for molecular diagnostic assays based on optical measurements of magnetic nanobead dynamics.

    Science.gov (United States)

    Donolato, Marco; Antunes, Paula; Bejhed, Rebecca S; Zardán Gómez de la Torre, Teresa; Østerberg, Frederik W; Strömberg, Mattias; Nilsson, Mats; Strømme, Maria; Svedlindh, Peter; Hansen, Mikkel F; Vavassori, Paolo

    2015-02-03

    We demonstrate detection of DNA coils formed from a Vibrio cholerae DNA target at picomolar concentrations using a novel optomagnetic approach exploiting the dynamic behavior and optical anisotropy of magnetic nanobead (MNB) assemblies. We establish that the complex second harmonic optical transmission spectra of MNB suspensions measured upon application of a weak uniaxial AC magnetic field correlate well with the rotation dynamics of the individual MNBs. Adding a target analyte to the solution leads to the formation of permanent MNB clusters, namely, to the suppression of the dynamic MNB behavior. We prove that the optical transmission spectra are highly sensitive to the formation of permanent MNB clusters and, thereby to the target analyte concentration. As a specific clinically relevant diagnostic case, we detect DNA coils formed via padlock probe recognition and isothermal rolling circle amplification and benchmark against a commercial equipment. The results demonstrate the fast optomagnetic readout of rolling circle products from bacterial DNA utilizing the dynamic properties of MNBs in a miniaturized and low-cost platform requiring only a transparent window in the chip.

  11. Developmental approach towards high resolution optical coherence tomography for glaucoma diagnostics

    Science.gov (United States)

    Kemper, Björn; Ketelhut, Steffi; Heiduschka, Peter; Thorn, Marie; Larsen, Michael; Schnekenburger, Jürgen

    2018-02-01

    Glaucoma is caused by a pathological rise in the intraocular pressure, which results in a progressive loss of vision by a damage to retinal cells and the optical nerve head. Early detection of pressure-induced damage is thus essential for the reduction of eye pressure and to prevent severe incapacity or blindness. Within the new European Project GALAHAD (Glaucoma Advanced, Label free High Resolution Automated OCT Diagnostics), we will develop a new low-cost and high-resolution OCT system for the early detection of glaucoma. The device is designed to improve diagnosis based on a new system of optical coherence tomography. Although OCT systems are at present available in ophthalmology centres, high-resolution devices are extremely expensive. The novelty of the new Galahad system is its super wideband light source to achieve high image resolution at a reasonable cost. Proof of concept experiments with cell and tissue Glaucoma test standards and animal models are planned for the test of the new optical components and new algorithms performance for the identification of Glaucoma associated cell and tissue structures. The intense training of the software systems with various samples should result in a increased sensitivity and specificity of the OCT software system.

  12. Transverse myelitis

    International Nuclear Information System (INIS)

    Black, M.J.; Motaghedi, B.; Robitaille, Y.

    1980-01-01

    Transverse myelitis is a known complication of radiation treatment for carcinoma of the heat and neck. In a five year period, 1970 to 1975, 120 patients with head and neck cancer received radiation as part of their treatment in this hospital. A review of the records of these patients showed only two cases of myelitis, an incidence of about 2%. This paper reviews the clinical syndrome; treatment and preventive measures are discussed and a survey of the literature is presented

  13. Study of electron-related intersubband optical properties in three coupled quantum wells wires with triangular transversal section

    Science.gov (United States)

    Tiutiunnyk, A.; Tulupenko, V.; Akimov, V.; Demediuk, R.; Morales, A. L.; Mora-Ramos, M. E.; Radu, A.; Duque, C. A.

    2015-11-01

    This work concerns theoretical study of confined electrons in a low-dimensional structure consisting of three coupled triangular GaAs/AlxGa1-xAs quantum wires. Calculations have been made in the effective mass and parabolic band approximations. In the calculations a diagonalization method to find the eigenfunctions and eigenvalues of the Hamiltonian was used. A comparative analysis of linear and nonlinear optical absorption coefficients and the relative change in the refractive index was made, which is tied to the intersubband electron transitions.

  14. Transverse Micro-structuring of Photonic Crystal Fibers for Industrial Sensors and Side Viewing Probes for Optical Coherence Tomography Applications

    Directory of Open Access Journals (Sweden)

    Sanjay KHER

    2010-05-01

    Full Text Available In this work, we report a simple and easily adaptable technique of lateral micro-machining of Photonic Crystal fibers (PCFs using modulated CO2-laser in conjunction with electrical arc system. The technique is controlled, convenient and precise over wide dimensions (50-250 mm. Lateral access to the holes of PCF provides additional flexibility for sensitive real time detection of gases such as green-house gases. Long period gratings are made in PCF through inscription of micro-grooves for sensitive detection of longitudinal strain. A unique and versatile PCF based probe for possible endoscopic Optical Coherence Tomography (OCT applications is reported.

  15. Detection of local birefringence in embedded fiber Bragg grating caused by concentrated transverse load using optical frequency domain reflectometry

    Science.gov (United States)

    Wada, D.; Murayama, H.; Igawa, H.

    2014-05-01

    We investigate the capability of local birefringence detection in an embedded fiber Bragg grating (FBG) using optical frequency domain reflectometry. We embed an FBG into carbon fiber reinforced plastic specimen, and conduct 3-point bending test. The cross-sectional stresses are applied to the FBG at the loading location in addition to the non-uniform longitudinal strain distribution over the length of the FBG. The local birefringence due to the cross-sectional stresses was successfully detected while the non-uniform longitudinal strain distribution was accurately measured.

  16. NON-INVASIVE DIAGNOSTICS OF NON-TUMOR DISORDERS WITH OPTICAL COHERENCE TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    A. E. Meller

    2016-01-01

    Full Text Available Introduction: The distinctive features of modern inflammatory diseases are their indolent course and predisposition to chronicity. Chronic inflammation is the basis for the development of serious disorders, including autoimmune and oncologic ones, and a  cause of major functional abnormalities of the human body. Diagnostics of chronic inflammation is associated with a number of problems which originate from a variety of clinical phenotypes and morphological forms, on the one hand, and from the rising prevalence of their latent course, on the other. In its turn, an adequate treatment choice may be based on understanding and accurate detection of etiological and morphological types of the disease. In this connection, development of novel diagnostic techniques, such as optical coherence tomography (OCT, is of utmost importance. Aim: To demonstrate feasibility of OCT in detection of morphological abnormalities associated with chronic inflammatory disorders of various localizations. Materials and methods: OCT diagnostics was performed in addition to standard diagnostic procedures in 225 patients with chronic inflammatory disorders of various localizations, such as chronic recurrent rhinitis, chronic latent salpingitis and chronic endometritis. For OCT, an “OCT-1300U” system was used, with central wavelength of 1280 nm, spatial resolution of 15–20 μm, image acquisition rate of 8 frames per second, imaging depth of 1.4 mm and a probe diameter of 2.4 mm. The following techniques of quantitative processing were used for processing of the OCT images. Quantitative characterization of histograms and image texture was performed with further determination of values typical for various images groups corresponding to particular states of biological tissues. Neural network was also employed with histograms and 2D Fourier transforms of the images as input data. Results: OCT laparoscopy allowed to obtain three types of OCT images of fallopian

  17. Handbook of Coherent-Domain Optical Methods Biomedical Diagnostics, Environmental Monitoring, and Materials Science

    CERN Document Server

    2013-01-01

    This Handbook provides comprehensive coverage of laser and coherent-domain methods as applied to biomedicine, environmental monitoring, and materials science. Worldwide leaders in these fields describe the fundamentals of light interaction with random media and present an overview of basic research. The latest results on coherent and polarization properties of light scattered by random media, including tissues and blood, speckles formation in multiple scattering media, and other non-destructive interactions of coherent light with rough surfaces and tissues, allow the reader to understand the principles and applications of coherent diagnostic techniques. The expanded second edition has been thoroughly updated with particular emphasis on novel coherent-domain techniques and their applications in medicine and environmental science. Volume 1 describes state-of-the-art methods of coherent and polarization optical imaging, tomography and spectroscopy; diffusion wave spectroscopy; elastic, quasi-elastic and inelasti...

  18. Reduced optical transmission of SiO2 fibers used in controlled fusion diagnostics

    International Nuclear Information System (INIS)

    Ramsey, A.T.; Adler, H.G.; Hill, K.W.

    1993-02-01

    We have subjected a silica core fiber optic cable to 4 years of low-level neutron and gamma radiation from Princeton's TFTR controlled fusion experiment The accumulated dose was 200 Gy. As a result of the radiation, we have measured increased attenuations of 100--300 db/km in the visible part of the spectrum, and a decrease of the numerical aperture. An attempt to decrease this damage by photobleaching failed. We argue that this failure is not unexpected, since the rate of damage is so slow and the time scale so long that the self-annealing process keeps the residual damage at the irreducible level seen in other experiments. The implications of these findings for controlled fusion diagnostics during upcoming experiments with highly reactive deuterium-tritium plasmas are discussed

  19. A twin optically-pumped far-infrared CH3OH laser for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, M.; Takeda, Y.; Tanigawa, S.; Nishizawa, A.; Noda, N.

    1979-11-01

    A twin optically-pumped far-infrared CH 3 OH laser has been constructed for use in plasma diagnostics. The anti-symmetric doublet due to the Raman-type resonant two-photon transition is reproducibly observed at 118.8 μm. With the 118.8-μm line, it is obtained from the frequency separation of the anti-symmetric doublet that the CH 3 OH absorption line center is 16 +- 1 MHz higher than the pump 9.7-μm P(36) CO 2 laser line center. It is shown that the Raman-type resonant two-photon transition is useful in order to get several-MHz phase modulation for the far-infrared laser interferometer. Some preliminary performances of this twin laser for the modulated interferometer are described. (author)

  20. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

    International Nuclear Information System (INIS)

    Fu Tairan; Cheng Xiaofang; Yang Zangjian

    2008-01-01

    We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution

  1. Optical diagnostics of lead and PbGa2S4 layered crystal laser plasmas

    International Nuclear Information System (INIS)

    Shuaibov, A.K.; Dashchenko, A.I.; Shevera, I.V.

    2001-01-01

    Paper presents the results of the optic diagnostics of plasma of laser flames formed from lead surface and PbGa 2 S 4 laminar crystal using a neodymium laser. It is shown that the most intensive lines in the lead laser plasma are as follows: 405.7, 368.3, 364.0 nm PbI and 220.4 nm PbII while for the laminar crystal base plasma - the combination of the most intensive lines of PbI and GaI emission. One determined the narrow point of recombination fluxes for the ion and the atomic components of laser plasma of lead and of PbGa 2 S 4 crystal. One conducted comparison study of emission dynamics of PbI and GaI lines in laser plasma of the respective metals and of PbGa 2 S 4 crystal [ru

  2. Femtosecond light distribution at skin and liver of rats: analysis for use in optical diagnostics

    International Nuclear Information System (INIS)

    Ullah, H; Mehmood, M S; Ikram, M; Atif, M; Firdous, S; Kurachi, C; Grecco, C; Nicolodelli, G; Bagnato, V S

    2010-01-01

    In this study we investigated the light distribution under femtosecond laser illumination and its correlation with the collected diffuse scattering at the surface of ex-vivo rat skin and liver. The reduced scattering coefficients μ' s for liver and skin due to different scatterers have been determined with Mie-scattering theory for each wavelength (800, 630, and 490 nm). Absorption coefficients μ a were determined by diffusion approximation equation in correlation with measured diffused reflectance experimentally for each wavelength (800, 630, and 490 nm). The total attenuation coefficient for each wavelength and type of tissue were determined by linearly fitting the log based normalized intensity. Both tissues are strongly scattering thick tissues. Our results may be relevant when considering the use of femtosecond laser illumination as an optical diagnostic tool

  3. Twin optically-pumped far-infrared CH3OH laser for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, M.; Takeda, Y.; Tanigawa, S.; Nishizawa, A.

    1980-01-01

    A twin optically-pumped far-infrared CH 3 OH laser has been constructed for use in plasma diagnostics. The antisymmetric doublet due to the Raman-type resonant two-photon transition is reproducibly observed at 118.8 microns. With the 118.8-micron line, it is found that CH 3 OH absorption line center is 16 + or - 1 MHz higher than the pump 9.7-micron P(36) CO 2 laser line center. It is shown that the Raman-type resonant two-photon transition is useful in order to get several MHz phase modulation for the far-infrared laser interferometer. Some preliminary performances of this twin laser for the modulated interferometer are described

  4. Response of optically stimulated luminescence dosimeters subjected to X-rays in diagnostic energy range

    International Nuclear Information System (INIS)

    Musa, Y; Hashim, S; Karim, M K A; Ang, W C; Salehhon, N; Bakar, K A

    2017-01-01

    The use of optically stimulated luminescence (OSL) for dosimetry applications has recently increased considerably due to availability of commercial OSL dosimeters (nanoDots) for clinical use. The OSL dosimeter has a great potential to be used in clinical dosimetry because of its prevailing advantages in both handling and application. However, utilising nanoDot OSLDs for dose measurement in diagnostic radiology can only be guaranteed when the performance and characteristics of the dosimeters are apposite. In the present work, we examined the response of commercially available nanoDot OSLD (Al 2 O 3 :C) subjected to X-rays in general radiography. The nanoDots response with respect to reproducibility, dose linearity and signal depletion were analysed using microStar reader (Landauer, Inc., Glenwood, IL). Irradiations were performed free-in-air using 70, 80 and 120 kV tube voltages and tube currents ranging from 10 – 100 mAs. The results showed that the nanoDots exhibit good linearity and reproducibility when subjected to diagnostic X-rays, with coefficient of variations (CV) ranging between 2.3% to 3.5% representing a good reproducibility. The results also indicated average of 1% signal reduction per readout. Hence, the nanoDots showed a promising potential for dose measurement in general X-ray procedure. (paper)

  5. Optical system for the Protein Crystallisation Diagnostics Facility (PCDF) on board the ISS

    Science.gov (United States)

    Joannes, Luc; Dupont, Olivier; Dewandel, Jean-Luc; Ligot, Renaud; Algrain, Hervé

    2004-06-01

    The Protein Crystallisation Diagnostic Facility (PCDF) is a multi-user facility to study the protein crystallisation under the conditions of micro-gravity onboard the International Space Station (ISS) Columbus facility. Large size protein crystals will growth under reduced gravity in thermally controlled reactors. A combination of diagnostic tools like video system, microscope, interferometer, and light scattering device shall help to understand the growth phenomena. Common methods of protein crystallisation shall be performed in PCDF: Dialysis where the protein solution and the salt solution are separated by a semi-permeable membrane. Extended Length Dialysis Batch where the saturation to get crystals is achieved by changing the concentration of the protein in the sample liquid. The overall ESA project is leaded by EADS Space Transportation, Friedrichshafen, Germany. Lambda-X is responsible for the Optical System (OS), with Verhaert Design and Development as sub-contractor for the mechanical design. The OS includes different compact parts: Original illumination systems based on LEDs of difference colours; Quantitative Mach-Zehnder interferometers to measure the concentration distribution around crystals; Imaging assemblies to visualize the protein volume with different field of views. The paper concentrates on the description of each part, and in particular on the imaging assembly which allow switching from one field of view to another by passive elements only.

  6. The evolution of whole field optical diagnostics for external transonic testing

    Science.gov (United States)

    Fry, K. A.; Bryanston-Cross, P.

    1992-09-01

    The diagnostic use of quantitative laser flow visualization techniques has increased rapidly over recent years. The limitations imposed by conventional single point techniques such as laser Doppler anemometry are addressed and how they have been overcome by the development of a new family of whole field measurement techniques is demonstrated. In particular near instantaneous whole field velocity data was obtained in a relatively hostile, industrial 2.74 m x 2.44 m transonic wind tunnel (TWT) at the Aircraft Research Association (ARA). The techniques were evaluated for their suitability for making quantitative measurements in the wing/pylon region of a model wing and engine combination. Three optical diagnostic techniques were successfully developed within the context of the ARA facility. The first technique, laser light sheet (LLS), combines the operation of a pulse laser and video capture system to provide a 'real time' visualization of the flow, whereas a second pulse laser technique, Particle Image Velocimetry (PIV) can be used to make specific quantitative whole field instantaneous velocity measurements. The third method, holography, was used to produce a stored three dimensional visualization of the unsteady and shock wave features of the transonic flow in the gully region. A description is made of their installation and operation, and examples are presented of current test results.

  7. Impurity-related optical properties in rectangular-transverse section GaAs-Ga{sub 1-x}Al{sub x}As quantum well wires: Hydrostatic pressure and electric field effects

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, J.W.; Duque, C.A. [Instituto de Fisica, Universidad de Antioquia, AA 1226, Medellin (Colombia); Lopez, S.Y. [Facultad de Educacion, Universidad de Antioquia, AA 1226, Medellin (Colombia); Rodriguez, A.H. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico (UNAM), Apdo. Postal 20-364, San Angel 01000, Mexico DF (Mexico); Porras-Montenegro, N. [Departamento de Fisica, Universidad del Valle, AA 25360, Cali (Colombia)

    2007-01-15

    Using a variational procedure within the effective mass approximation, we have calculated the influence of an applied electric field and hydrostatic pressure on the shallow-impurity-related optical properties in a rectangular-transverse section GaAs-Ga{sub 1-x}Al{sub x}As quantum well wire. The electric field is applied in the plane of the transverse section of the wire and different angular directions have been considered. The results presented are for the impurity binding energy, its corresponding density of impurity states, and impurity-related transition energy and polarizability. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Optical coherence tomography in diagnostics of precancer and cancer of human bladder

    Science.gov (United States)

    Zagaynova, Elena V.; Streltsova, Olga S.; Gladkova, Natalia D.; Shakhova, Natalia M.; Feldchtein, Felix I.; Kamensky, Vladislav A.; Gelikonov, Grigory V.; Snopova, Ludmila B.; Donchenko, Ekaterina V.

    2004-07-01

    Our goal was statistical assessment of the in vivo cystoscopic optical coherence tomography (OCT) ability to detect neoplasia in human urinary bladder. We analyzed major reasons of false positive and false negative image recognition results. Optical coherence tomography was performed to image the bladder during cystoscopy. The study enrolled 63 patients with suspicion for bladder cancer and scheduled for cystoscopy. The diagnosis was established by histopathology examination of a biopsy. Each biopsy site was examined by OCT. Benign conditions were diagnosed for 31 patients, and dysplasia or carcinoma were diagnosed for 32 patients. Six physicians blinded to all clinical data participated in the dichotomy recognition (malignant or benign) of the OCT images. 98% sensitivity and 72% specificity for the OCT recognition of dysplastic/malignant versus benign/reactive conditions of the bladder are demonstrated. Total error rate was 14.8%. The interobserver agreement multi-rater kappa coefficient is 0.80. The superficial and invasive bladder cancer and high-grade dysplasia were recognized with minimum error rate ranging from 0 to 3.3%. High sensitivity and good specificity of the OCT method in the diagnostics of bladder neoplasia makes OCT a promising complementary cystoscopic technique for non-invasive evaluation of zones suspicious for high-grade dysplasia and cancer.

  9. Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging

    Science.gov (United States)

    Roncali, Emilie; Mosleh-Shirazi, Mohammad Amin; Badano, Aldo

    2017-10-01

    Computational modelling of radiation transport can enhance the understanding of the relative importance of individual processes involved in imaging systems. Modelling is a powerful tool for improving detector designs in ways that are impractical or impossible to achieve through experimental measurements. Modelling of light transport in scintillation detectors used in radiology and radiotherapy imaging that rely on the detection of visible light plays an increasingly important role in detector design. Historically, researchers have invested heavily in modelling the transport of ionizing radiation while light transport is often ignored or coarsely modelled. Due to the complexity of existing light transport simulation tools and the breadth of custom codes developed by users, light transport studies are seldom fully exploited and have not reached their full potential. This topical review aims at providing an overview of the methods employed in freely available and other described optical Monte Carlo packages and analytical models and discussing their respective advantages and limitations. In particular, applications of optical transport modelling in nuclear medicine, diagnostic and radiotherapy imaging are described. A discussion on the evolution of these modelling tools into future developments and applications is presented. The authors declare equal leadership and contribution regarding this review.

  10. Optical diagnostics of diesel spray injections and combustion in a high-pressure high-temperature cell

    NARCIS (Netherlands)

    Bougie, H.J.T.; Tulej, M.; Dreier, T.; Dam, N.J.; Meulen, J.J. ter; Gerber, T.

    2005-01-01

    We report on spatially and temporally resolved optical diagnostic measurements of propagation and combustion of diesel sprays introduced through a single-hole fuel injector into a constant volume, high-temperature, high-pressure cell. From shadowgraphy images in non-reacting environments of pure

  11. Transverse tomography and radiotherapy

    International Nuclear Information System (INIS)

    Leer, J.W.H.

    1982-01-01

    This study was intended to delineate the indications for radiotherapy treatment-planning with the help of computerized axial tomography (C.T.) and transverse analog tomography (T.A.T.). Radiotherapy localisation procedures with the conventional method (simulator), with the CT-scanner and with the transverse analog tomograph (T.A.T., Simtomix, Oldelft) were compared. As criterium for evaluation differences in reconstruction drawing based on these methods were used. A certain method was judged ''superior'' to another if the delineation of the target volume was more accurate, if a better impression was gained of the site of (for irradiation) organs at risk, or if the localisation could only be performed with that method. The selected group of patients consisted of 120 patients for whom a reconstruction drawing in the transverse plane was made according to the treatment philosophy. In this group CT-assisted localisation was judged on 68 occasions superior to the conventional method. In a number of cases it was found that a ''standard'' change in a standard target volume, on the base of augmented anatomical knowledge, made the conventional method sufficient. The use of CT-scanner for treatment planning was estimated. For ca. 270/1000 new patients a CT-scan is helpful (diagnostic scan), for 140 of them the scan is necessary (planning scan). The quality of the anatomical information obtained with the T.A.T. does not yet fall within acceptable limits, but progress has been made. (Auth.)

  12. Optical emission spectroscopy diagnostics of an atmospheric pressure direct current microplasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Sismanoglu, B.N., E-mail: bogos@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil); Amorim, J., E-mail: jayr.amorim@bioetanol.org.b [Centro de Ciencia e Tecnologia do Bioetanol - CTBE, Caixa Postal 6170, 13083-970 Campinas, Sao Paulo (Brazil); Souza-Correa, J.A., E-mail: jorge.correa@bioetanol.org.b [Centro de Ciencia e Tecnologia do Bioetanol - CTBE, Caixa Postal 6170, 13083-970 Campinas, Sao Paulo (Brazil); Oliveira, C., E-mail: carlosf@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil); Gomes, M.P., E-mail: gomesmp@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil)

    2009-11-15

    This paper is about the use of optical emission spectroscopy as a diagnostic tool to determine the gas discharge parameters of a direct current (98% Ar-2% H{sub 2}) non-thermal microplasma jet, operated at atmospheric pressure. The electrical and optical behaviors were studied to characterize this glow discharge. The microplasma jet was investigated in the normal and abnormal glow regimes, for current ranging from 10 to 130 mA, at approx 220 V of applied voltage for copper cathode. OH (A {sup 2}SIGMA{sup +}, nu = 0 -> X {sup 2}PI, nu' = 0) rotational bands at 306.357 nm and also the 603.213 nm Ar I line, which is sensitive to van der Waals broadening, were used to determine the gas temperature, which ranges from 550 to 800 K. The electron number densities, ranging from 6.0 x 10{sup 14} to 1.4 x 10{sup 15} cm{sup -3}, were determined through a careful analysis of the main broadening mechanisms of the H{sub beta} line. From both 603.213 nm and 565.070 nm Ar I line broadenings, it was possible to obtain simultaneously electron number density and temperature (approx 8000 K). Excitation temperatures were also measured from two methods: from two Cu I lines and from Boltzmann-plot of 4p-4s and 5p-4s Ar I transitions. By employing H{sub alpha} line, the hydrogen atoms' H temperature was estimated (approx 18,000 K) and found to be surprisingly hotter than the excitation temperature.

  13. Development of high-speed and wide-angle visible observation diagnostics on Experimental Advanced Superconducting Tokamak using catadioptric optics

    International Nuclear Information System (INIS)

    Yang, J. H.; Hu, L. Q.; Zang, Q.; Han, X. F.; Shao, C. Q.; Sun, T. F.; Chen, H.; Wang, T. F.; Li, F. J.; Hu, A. L.; Yang, X. F.

    2013-01-01

    A new wide-angle endoscope for visible light observation on the Experimental Advanced Superconducting Tokamak (EAST) has been recently developed. The head section of the optical system is based on a mirror reflection design that is similar to the International Thermonuclear Experimental Reactor-like wide-angle observation diagnostic on the Joint European Torus. However, the optical system design has been simplified and improved. As a result, the global transmittance of the system is as high as 79.6% in the wavelength range from 380 to 780 nm, and the spatial resolution is <5 mm for the full depth of field (4000 mm). The optical system also has a large relative aperture (1:2.4) and can be applied in high-speed camera diagnostics. As an important diagnostic tool, the optical system has been installed on the HT-7 (Hefei Tokamak-7) for its final experimental campaign, and the experiments confirmed that it can be applied to the investigation of transient processes in plasma, such as ELMy eruptions in H-mode, on EAST

  14. Optical diagnostics of CO2 laser-fusion targets using backscattered light

    International Nuclear Information System (INIS)

    Casperson, D.E.

    1981-01-01

    With the f/2.4 focusing optics on one of the eight Helios CO 2 laser beam lines, direct backscattered light from a variety of glass microballoon targets has been observed. The quantities that have been measured include: (1) the total backscattered energy; (2) relative amplitudes of the backscattered fundamental and low harmonics (n = 1, 2, 3) of the 10.6 μm incident light; (3) the 3/2 harmonic emission from a double pulse backscatter experiment; (4) the temporally resolved 10.6 μm light using a fast pyroelectric detector and a Los Alamos 5-GHz oscilloscope; and (5) the time-integrated spectrally resolved fundamental using a 3/4 meter spectrometer and a high resolution pyroelectric detector array (resolution approx. 40 A at 10.6 μm). The suitability of these diagnostics for evaluating the CO 2 laser plasma in terms of stimulated scattering processes, plasma density gradients, velocity of the critical surface, etc., is discussed

  15. Advanced optical diagnostics for a coal-fired MHD retrofit of an existing power station

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1990-01-01

    The retrofit concept involves integrating a magnetohydrodynamic (MHD) power generation facility with an existing commercial steam power plant. The MHD power train will be 250 MW t and represents a 5:1 scale-up of existing developmental, proof-of-concept (POC) facilities. The program provides a cost effective way to demonstrate the effectiveness, reliability, and operability of the technology and a basis for future commercialization. An aspect of the program must be to accumulate information on component performance and scale-up relations to enable a smooth transition to commercial plant designs. Special state-of-the-art optical diagnostic instrumentation systems are required for this modern energy conversion technology. In-situ measurements with such systems provide a clearer understanding of the processes involved in the ash/seed-laden MHD gas stream, fundamental scale-up data, performance monitors, and a basis for improved control strategies and control instruments. The types of instrumentation, the measurement locations and frequency, and the benefits for the retrofit program are discussed

  16. The design of the optical Thomson scattering diagnostic for the National Ignition Facility.

    Science.gov (United States)

    Datte, P S; Ross, J S; Froula, D H; Daub, K D; Galbraith, J; Glenzer, S; Hatch, B; Katz, J; Kilkenny, J; Landen, O; Manha, D; Manuel, A M; Molander, W; Montgomery, D; Moody, J; Swadling, G F; Weaver, J

    2016-11-01

    The National Ignition Facility (NIF) is a 192 laser beam facility designed to support the Stockpile Stewardship, High Energy Density and Inertial Confinement Fusion (ICF) programs. We report on the design of an Optical Thomson Scattering (OTS) diagnostic that has the potential to transform the community's understanding of NIF hohlraum physics by providing first principle, local, time-resolved measurements of under-dense plasma conditions. The system design allows operation with different probe laser wavelengths by manual selection of the appropriate beam splitter and gratings before the shot. A deep-UV probe beam (λ 0 -210 nm) will be used to optimize the scattered signal for plasma densities of 5 × 10 20 electrons/cm 3 while a 3ω probe will be used for experiments investigating lower density plasmas of 1 × 10 19 electrons/cm 3 . We report the phase I design of a two phase design strategy. Phase I includes the OTS telescope, spectrometer, and streak camera; these will be used to assess the background levels at NIF. Phase II will include the design and installation of a probe laser.

  17. ICALEO '89 - Optical methods in flow and particle diagnostics; Proceedings of the Meeting, Orlando, FL, Oct. 15-20, 1989

    Science.gov (United States)

    Long, Marshall B.

    Various papers on optical methods in flow and particle diagnostics are presented. Individual topics addressed include: swirl effects on confined flows in a model of a dump combustor, new analog optical method for data evaluation in laser Doppler anemometry, catadioptric optics for laser Doppler velocimeter applications, mapping of velocity flow field using the laser two-focus technique, engineering applications of particle image velocimeters, quantitative fluid flow analysis by laser velocimetry and numerical processing, optical analysis of particle image velocimetry data. Also discussed are: measuring turbulence in reversing flows by particle image velocimeter, two-color particle velocimetry, data evaluation in particle image velocimetry using spatial light modulator, statistical investigation of errors in particle image velocimetry, optimization of particle image velocimeters, visualization of internal structure in volumetric data, scalar measurements in two, three, and four dimensions.

  18. Microwave and optical diagnostics in a gadolinium plasma; Diagnostics hyperfrequence et optique dans un plasma magnetise de gadolinium

    Energy Technology Data Exchange (ETDEWEB)

    Larousse, B. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. des Procedes d`Enrichissement]|[Conservatoire National des Arts et Metiers (CNAM), 75 - Paris (France)

    1997-12-31

    The optimization of the separation process of the gadolinium isotopes by Ion Cyclotron Resonance requires a precise knowledge of the physical characteristics of the plasma. Thus, two kinds of diagnostics have been developed: the first one to estimate the microwave power inside the source and the second one to measure the density of atomic and ionic of the gadolinium inside the plasma source and in front of the collector. Microwave diagnostic: A microstrip antenna has been designed and developed in order to characterize the microwave at 36 GHz frequency in the plasma source. The experimental results for different plasma regimes are presented. The measurements inside the plasma source show a maximum of microwave absorption for an argon pressure of 10{sup -4} mb (93% of absorption of the incident wave in the conditions of isotope separation). Laser absorption diagnostic: The theory of laser absorption in presence of a magnetic field is recalled and the first results are presented. In the spectral range between 560 and 620 nm, corresponding to high energy levels of gadolinium, no signal is obtained so that the density is below the detection limit 10{sup 10} cm{sup -3}. In the spectral range between 380 and 400 nm, two lines are observed, issue from the fundamental and metastable (633 cm{sup -1}) levels. The density of metastable level of gadolinium ions is about 10{sup 10} cm{sup -3} with a relative precision of 15 % and its variation is studied as a function of argon pressure, at different sections of the plasma column (source, collector). The achieved set of measurements has been performed in order to check the theoretical models. (author) 32 refs.

  19. Diagnostic potential of iris cross-sectional imaging in albinism using optical coherence tomography.

    Science.gov (United States)

    Sheth, Viral; Gottlob, Irene; Mohammad, Sarim; McLean, Rebecca J; Maconachie, Gail D E; Kumar, Anil; Degg, Christopher; Proudlock, Frank A

    2013-10-01

    To characterize in vivo anatomic abnormalities of the iris in albinism compared with healthy controls using anterior segment optical coherence tomography (AS-OCT) and to explore the diagnostic potential of this technique for albinism. We also investigated the relationship between iris abnormalities and other phenotypical features of albinism. Prospective cross-sectional study. A total of 55 individuals with albinism and 45 healthy controls. We acquired 4.37×4.37-mm volumetric scans (743 A-scans, 50 B-scans) of the nasal and temporal iris in both eyes using AS-OCT (3-μm axial resolution). Iris layers were segmented and thicknesses were measured using ImageJ software. Iris transillumination grading was graded using Summers and colleagues' classification. Retinal OCT, eye movement recordings, best-corrected visual acuity (BCVA), visual evoked potential (VEP), and grading of skin and hair pigmentation were used to quantify other phenotypical features associated with albinism. Iris AS-OCT measurements included (1) total iris thickness, (2) stroma/anterior border (SAB) layer thickness, and (3) posterior epithelial layer (PEL) thickness. Correlation with other phenotypical measurements, including (1) iris transillumination grading, (2) retinal layer measurements at the fovea, (3) nystagmus intensity, (4) BCVA, (5) VEP asymmetry, (6) skin pigmentation, and (7) hair pigmentation (of head hair, lashes, and brows). The mean iris thickness was 10.7% thicker in controls (379.3 ± 44.0 μm) compared with the albinism group (342.5 ± 52.6 μm; P>0.001), SAB layers were 5.8% thicker in controls (315.1 ± 43.8 μm) compared with the albinism group (297.7 ± 50.0 μm; P=0.044), and PEL was 44.0% thicker in controls (64.1 ± 11.7 μm) compared with the albinism group (44.5 ± 13.9 μm; Palbinism. Phenotypic features of albinism, such as skin and hair pigmentation, BCVA, and nystagmus intensity, were significantly correlated to AS-OCT iris thickness measurements. We have

  20. Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases.

    Science.gov (United States)

    Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P

    2018-01-01

    Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4

  1. Diagnostic capability of scanning laser polarimetry with and without enhanced corneal compensation and optical coherence tomography.

    Science.gov (United States)

    Benítez-del-Castillo, Javier; Martinez, Antonio; Regi, Teresa

    2011-01-01

    To compare the abilities of the current commercially available versions of scanning laser polarimetry (SLP) and optical coherence tomography (OCT), SLP-variable corneal compensation (VCC), SLP-enhanced corneal compensation (ECC), and high-definition (HD) OCT, in discriminating between healthy eyes and those with early-to-moderate glaucomatous visual field loss. Healthy volunteers and patients with glaucoma who met the eligibility criteria were consecutively enrolled in this prospective, cross-sectional, observational study. Subjects underwent complete eye examination, automated perimetry, SLP-ECC, SLP-VCC, and HD-OCT. Scanning laser polarimetry parameters were recalculated in 90-degree segments (quadrants) in the calculation circle to be compared. Areas under the receiver operating characteristic curve (AUROCs) were calculated for every parameter in order to compare the ability of each imaging modality to differentiate between normal and glaucomatous eyes. Fifty-five normal volunteers (mean age 59.1 years) and 33 patients with glaucoma (mean age 63.8 years) were enrolled. Average visual field mean deviation was -6.69 dB (95% confidence interval -8.07 to -5.31) in the glaucoma group. The largest AUROCs were associated with nerve fiber indicator (0.880 and 0.888) for the SLP-VCC and SLP-ECC, respectively, and with the average thickness in the HD-OCT (0.897). The best performing indices for the SLP-VCC, SLP-ECC, and HD OCT gave similar AUROCs, showing moderate diagnostic accuracy in patients with early to moderate glaucoma. Further studies are needed to evaluate the ability of these technologies to discriminate between normal and glaucomatous eyes.

  2. Statistical methods for transverse beam position diagnostics with higher order modes in third harmonic 3.9 GHz superconducting accelerating cavities at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Pei, E-mail: pei.zhang@desy.de [School of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Deutsches Elektronen-Synchrotron (DESY), Notkestraße 85, D-22607 Hamburg (Germany); Cockcroft Institute of Science and Technology, Daresbury WA4 4AD (United Kingdom); Baboi, Nicoleta [Deutsches Elektronen-Synchrotron (DESY), Notkestraße 85, D-22607 Hamburg (Germany); Jones, Roger M. [School of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Cockcroft Institute of Science and Technology, Daresbury WA4 4AD (United Kingdom)

    2014-01-11

    Beam-excited higher order modes (HOMs) can be used to provide beam diagnostics. Here we focus on 3.9 GHz superconducting accelerating cavities. In particular we study dipole mode excitation and its application to beam position determinations. In order to extract beam position information, linear regression can be used. Due to a large number of sampling points in the waveforms, statistical methods are used to effectively reduce the dimension of the system, such as singular value decomposition (SVD) and k-means clustering. These are compared with the direct linear regression (DLR) on the entire waveforms. A cross-validation technique is used to study the sample independent precisions of the position predictions given by these three methods. A RMS prediction error in the beam position of approximately 50 μm can be achieved by DLR and SVD, while k-means clustering suggests 70 μm.

  3. Statistical methods for transverse beam position diagnostics with higher order modes in third harmonic 3.9 GHz superconducting accelerating cavities at FLASH

    CERN Document Server

    Zhang, P; Jones, R M

    2014-01-01

    Beam-excited higher order modes (HOM) can be used to provide beam diagnostics. Here we focus on 3.9 GHz superconducting accelerating cavities. In particular we study dipole mode excitation and its application to beam position determinations. In order to extract beam position information, linear regression can be used. Due to a large number of sampling points in the waveforms, statistical methods are used to effectively reduce the dimension of the system, such as singular value decomposition (SVD) and k-means clustering. These are compared with the direct linear regression (DLR) on the entire waveforms. A cross-validation technique is used to study the sample independent precisions of the position predictions given by these three methods. A RMS prediction error in the beam position of approximately 50 micron can be achieved by DLR and SVD, while k-means clustering suggests 70 micron.

  4. Utility of optical heterodyne displacement sensing and laser ultrasonics as in situ process control diagnostic for additive manufacturing

    Science.gov (United States)

    Manzo, Anthony J.; Helvajian, Henry

    2018-04-01

    An in situ process control monitor is presented by way of experimental results and simulations, which utilizes a pulsed laser ultrasonic source as a probe and an optical heterodyne displacement meter as a sensor. The intent is for a process control system that operates in near real time, is nonintrusive, and in situ: A necessary requirement for a serial manufacturing technology such as additive manufacturing (AM). We show that the diagnostic approach has utility in characterizing the local temperature, the area of the heat-affected zone, and the surface roughness (Ra ˜ 0.4 μm). We further demonstrate that it can be used to identify solitary defects (i.e., holes) on the order of 10 to 20 μm in diameter. Moreover, the technique shows promise in measuring properties of materials with features that have a small radius of curvature. We present results for a thin wire of ˜650 μm in diameter. By applying multiple pairs of probe-sensor systems, the diagnostic could also measure the local cooling rate on the scale of 1 μs. Finally, while an obvious application is used in AM technology, then all optical diagnostics could be applied to other manufacturing technologies.

  5. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  6. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic.

    Science.gov (United States)

    Swadling, G F; Ross, J S; Datte, P; Moody, J; Divol, L; Jones, O; Landen, O

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm -2 . This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 10 19 cm -2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  7. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam.

    Science.gov (United States)

    Froula, D H; Boni, R; Bedzyk, M; Craxton, R S; Ehrne, F; Ivancic, S; Jungquist, R; Shoup, M J; Theobald, W; Weiner, D; Kugland, N L; Rushford, M C

    2012-10-01

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (~1 - μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10(4) with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  8. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

    International Nuclear Information System (INIS)

    Froula, D. H.; Boni, R.; Bedzyk, M.; Craxton, R. S.; Ehrne, F.; Ivancic, S.; Jungquist, R.; Shoup, M. J.; Theobald, W.; Weiner, D.; Kugland, N. L.; Rushford, M. C.

    2012-01-01

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75–80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (∼1 −μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10 4 with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  9. Optical beam diagnostics at the Electron Stretcher Accelerator ELSA; Optische Strahldiagnose an der Elektronen-Stretcher-Anlage ELSA

    Energy Technology Data Exchange (ETDEWEB)

    Zander, Sven

    2013-10-15

    At the ELectron Stretcher Accelerator ELSA, a resonant excitation of the horizontal particle oscillations is used to extract the electrons to the experiments. This so-called resonance extraction influences the properties of the extracted beam. The emittance, as a number of the beam quality, was determined by using synchrotron light monitors. To enable broad investigations of the emittance a system of synchrotron light monitors was set up. This system was used to measure the influence of the extraction method on the emittance. Time resolved measurements were conducted to investigate the development of the emittance during an accelerator cycle. To improve the optical beam diagnostics a new beamline to an external laboratory was constructed. There, a new high resolution synchrotron light monitor was commissioned. In addition, a streak camera has been installed to enable longitudinal diagnostics of the beam profiles. First measurements of the longitudinal charge distribution with a time resolution in the range of a few picoseconds were conducted successfully.

  10. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

    Energy Technology Data Exchange (ETDEWEB)

    Froula, D. H.; Boni, R.; Bedzyk, M.; Craxton, R. S.; Ehrne, F.; Ivancic, S.; Jungquist, R.; Shoup, M. J.; Theobald, W.; Weiner, D. [Laboratory for Laser Energetics, University of Rochester, 250 E. River Rd., Rochester, New York 14616 (United States); Kugland, N. L.; Rushford, M. C. [Lawrence Livermore National Laboratory, University of California, P. O. Box 808, Livermore, California 94551 (United States)

    2012-10-15

    A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

  11. Electron Impact Excitation Cross Sections of Xenon for Optical Plasma Diagnostic

    National Research Council Canada - National Science Library

    Srivastava, Rajesh

    2007-01-01

    In this project the researcher had taken up the calculation of xenon apparent emission-excitation cross sections for emission lines that have diagnostic value in the analysis of Xe-propelled electric thruster plasmas...

  12. Mitochondrial DNA analysis as a diagnostic tool in singleton cases of Leber's hereditary optic neuropathy

    NARCIS (Netherlands)

    Oostra, R. J.; Bolhuis, P. A.; Bleeker-Wagemakers, E. M.

    1993-01-01

    Leber's hereditary optic neuropathy (LHON) is characterized by subacute loss of central vision due to bilateral optic nerve atrophy accompanied by several nonspecific clinical findings. The only pathognomonic feature is its strictly maternal inheritance. It was therefore impossible to establish the

  13. Development of high-power optically-pumped far-infrared lasers for plasma diagnostics

    International Nuclear Information System (INIS)

    Yamanaka, Masanobu; Yamanaka, Tatsuhiko; Mitsuishi, Akiyoshi; Fujita, Shigeru; Tsunawaki, Yoshiaki.

    1982-01-01

    The activities for developing an over 0.1-MW optically-pumped 385-μm D 2 O laser and a CW optically-pumped 382.9-μm CH 2 F 2 laser as local oscillator for measurement of ion temperature in Tokamaks are described. (author)

  14. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    International Nuclear Information System (INIS)

    Monteiro, Mario L.R.; Goncalves, Allan C.P.; Silva, Carla T.M.; Moura, Janete P.; Ribeiro, Carolina S.; Gebrim, Eloisa M.M.S.; Universidade de Sao Paulo; Universidade de Sao Paulo

    2008-01-01

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values (±SD) were 64.47% ± 6.06% and 49.44% ± 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p 60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  15. Phenotype analysis of early risk factors from electronic medical records improves image-derived diagnostic classifiers for optic nerve pathology

    Science.gov (United States)

    Chaganti, Shikha; Nabar, Kunal P.; Nelson, Katrina M.; Mawn, Louise A.; Landman, Bennett A.

    2017-03-01

    We examine imaging and electronic medical records (EMR) of 588 subjects over five major disease groups that affect optic nerve function. An objective evaluation of the role of imaging and EMR data in diagnosis of these conditions would improve understanding of these diseases and help in early intervention. We developed an automated image processing pipeline that identifies the orbital structures within the human eyes from computed tomography (CT) scans, calculates structural size, and performs volume measurements. We customized the EMR-based phenome-wide association study (PheWAS) to derive diagnostic EMR phenotypes that occur at least two years prior to the onset of the conditions of interest from a separate cohort of 28,411 ophthalmology patients. We used random forest classifiers to evaluate the predictive power of image-derived markers, EMR phenotypes, and clinical visual assessments in identifying disease cohorts from a control group of 763 patients without optic nerve disease. Image-derived markers showed more predictive power than clinical visual assessments or EMR phenotypes. However, the addition of EMR phenotypes to the imaging markers improves the classification accuracy against controls: the AUC improved from 0.67 to 0.88 for glaucoma, 0.73 to 0.78 for intrinsic optic nerve disease, 0.72 to 0.76 for optic nerve edema, 0.72 to 0.77 for orbital inflammation, and 0.81 to 0.85 for thyroid eye disease. This study illustrates the importance of diagnostic context for interpretation of image-derived markers and the proposed PheWAS technique provides a flexible approach for learning salient features of patient history and incorporating these data into traditional machine learning analyses.

  16. A Piezoelectroluminescent Fiber-Optical Sensor for Diagnostics of the 3D Stress State in Composite Structures

    Science.gov (United States)

    Pan'kov, A. A.

    2018-05-01

    The mathematical model of a piezoelectroluminescent fiber-optical sensor is developed for diagnostics of the 3D stress state of composite structures. The sensor model is a coaxial sector-compound layered cylinder consisting of a central optical fiber with electroluminescent and piezoelectric layers and an external uniform elastic buffer layer. The electroluminescent and piezoelectric layers are separated by radial-longitudinal boundaries, common for both layers, into geometrically equal six "measuring elements" — cylindrical two-layered sectors. The directions of 3D polarization of the piezoelectric phases and the frequencies of luminous efficacy of the electroluminescent phases are different in each sector. In the sensor, a thin translucent "internal" controlling electrode is located between the optical fiber and the electroluminescent layer, and the piezoelectric layer is coated by a thin "external" controlling electrode. The results of numerical modeling of the nonuniform coupled electroelastic fields of the piezoelectroluminescent fiber-optical sensor in the loaded "representative volume" of a composite, taking into account the action of the controlling voltage on the internal and external electrodes, of a numerical calculation of "informative and controlling coefficients" of the sensor, and of testing of an arbitrary 3D stress of state of a unidirectional glass-fiber plastic by the finite-element method are presented.

  17. Transillumination optical sensing for biomedicine and diagnostics: feasibility of early diagnosis for rheumatoid arthritis

    International Nuclear Information System (INIS)

    Yuasa, Tetsuya; Sasaki, Yoshiaki; Devaraj, Balasigamani; Akatsuka, Takao; Tanosaki, Shinji; Takagi, Michiaki; Taniguchi, Hiroshi

    2002-01-01

    Optical computed tomography of thick biological tissues remains an elusive but fascinating area of research with potential applications in biomedicine. Our measurement use the optical heterodyne detection method wherein CW and single frequency lasers are used to exploit the maximum advantages of heterodyne detection such as high directionality, selectivity and sensitivity. We have demonstrated the advantages and capabilities of the measurement technique for transillumination optical computed tomography in biomedicine. Biological tissues by nature are heterogeneous, complex and forward scattering media. The optical heterodyne detection method enables selective filtering of the directional coherence retaining emergent photons for image reconstruction similar to those as in X-ray CT. Here, we report our recent results on transillumination in vivo imaging for diagnosis of rheumatoid arthritis (RA). In particular, we demonstrate the feasibility of early diagnosis for RA by comparing the laser tomographic images of fingers of an RA patient and a healthy volunteer. (author)

  18. Transverse and longitudinal angular momenta of light

    Energy Technology Data Exchange (ETDEWEB)

    Bliokh, Konstantin Y., E-mail: k.bliokh@gmail.com [Center for Emergent Matter Science, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Nonlinear Physics Centre, RSPhysE, The Australian National University, Canberra, ACT 0200 (Australia); Nori, Franco [Center for Emergent Matter Science, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Physics Department, University of Michigan, Ann Arbor, MI 48109-1040 (United States)

    2015-08-26

    We review basic physics and novel types of optical angular momentum. We start with a theoretical overview of momentum and angular momentum properties of generic optical fields, and discuss methods for their experimental measurements. In particular, we describe the well-known longitudinal (i.e., aligned with the mean momentum) spin and orbital angular momenta in polarized vortex beams. Then, we focus on the transverse (i.e., orthogonal to the mean momentum) spin and orbital angular momenta, which were recently actively discussed in theory and observed in experiments. First, the recently-discovered transverse spin  angular momenta appear in various structured fields: evanescent waves, interference fields, and focused beams. We show that there are several kinds of transverse spin angular momentum, which differ strongly in their origins and physical properties. We describe extraordinary features of the transverse optical spins and overview recent experiments. In particular, the helicity-independent transverse spin inherent in edge evanescent waves offers robust spin–direction coupling at optical interfaces (the quantum spin Hall effect of light). Second, we overview the transverse orbital angular momenta of light, which can be both extrinsic and intrinsic. These two types of the transverse orbital angular momentum are produced by spatial shifts of the optical beams (e.g., in the spin Hall effect of light) and their Lorentz boosts, respectively. Our review is underpinned by a unified theory of the angular momentum of light based on the canonical momentum and spin densities, which avoids complications associated with the separation of spin and orbital angular momenta in the Poynting picture. It allows us to construct a comprehensive classification of all known optical angular momenta based on their key parameters and main physical properties.

  19. Comparison of advanced optical imaging techniques with current otolaryngology diagnostics for improved middle ear assessment (Conference Presentation)

    Science.gov (United States)

    Nolan, Ryan M.; Shelton, Ryan L.; Monroy, Guillermo L.; Spillman, Darold R.; Novak, Michael A.; Boppart, Stephen A.

    2016-02-01

    Otolaryngologists utilize a variety of diagnostic techniques to assess middle ear health. Tympanometry, audiometry, and otoacoustic emissions examine the mobility of the tympanic membrane (eardrum) and ossicles using ear canal pressure and auditory tone delivery and detection. Laser Doppler vibrometry provides non-contact vibrational measurement, and acoustic reflectometry is used to assess middle ear effusion using sonar. These technologies and techniques have advanced the field beyond the use of the standard otoscope, a simple tissue magnifier, yet the need for direct visualization of middle ear disease for superior detection, assessment, and management remains. In this study, we evaluated the use of portable optical coherence tomography (OCT) and pneumatic low-coherence interferometry (LCI) systems with handheld probe delivery to standard tympanometry, audiometry, otoacoustic emissions, laser Doppler vibrometry, and acoustic reflectometry. Comparison of these advanced optical imaging techniques and current diagnostics was conducted with a case study subject with a history of unilateral eardrum trauma. OCT and pneumatic LCI provide novel dynamic spatiotemporal structural data of the middle ear, such as the thickness of the eardrum and quantitative detection of underlying disease pathology, which could allow for more accurate diagnosis and more appropriate management than currently possible.

  20. Transversity: Theory and phenomenology

    Energy Technology Data Exchange (ETDEWEB)

    D' Alesio, Umberto [Dipartimento di Fisica, Universita di Cagliari, Cittadella Universitaria, and Istituto Nazionale di Fisica Nucleare, Sezione di Cagliari, C. P. 170, I-09042 Monserrato (Italy)

    2013-04-15

    The distribution of transversely polarized quarks inside a transversely polarized nucleon, known as transversity, encodes a basic piece of information on the nucleon structure, sharing the same status with the more familiar unpolarized and helicity distributions. I will review its properties and discuss different ways to access it, with highlights and limitations. Recent phenomenological extractions and perspectives are also presented.

  1. Transversity: Theory and phenomenology

    International Nuclear Information System (INIS)

    D'Alesio, Umberto

    2013-01-01

    The distribution of transversely polarized quarks inside a transversely polarized nucleon, known as transversity, encodes a basic piece of information on the nucleon structure, sharing the same status with the more familiar unpolarized and helicity distributions. I will review its properties and discuss different ways to access it, with highlights and limitations. Recent phenomenological extractions and perspectives are also presented.

  2. Tomography feasibility study on the optical emission spectroscopy diagnostic for the negative ion source of the ELISE test facility

    International Nuclear Information System (INIS)

    Bonomo, F; Agostini, M; Brombin, M; Pasqualotto, R; Fantz, U; Franzen, P; Wünderlich, D

    2014-01-01

    A feasibility study of a spectroscopic tomographic diagnostic for the emissivity reconstruction of the plasma parameters in the large negative ion source of the test facility ELISE is described. Tomographic tools are developed to be applied to the measurements of the ELISE optical emission spectroscopy (OES) diagnostic, in order to reconstruct the emissivity distribution from hydrogen (or deuterium) plasma close to the plasma grid, where negative ions are produced and extracted to be accelerated. Various emissivity phantoms, both symmetric and asymmetric, reproducing different plasma experimental conditions have been simulated to test the tomographic algorithm. The simultaneous algebraic reconstruction technique has been applied, accounting for the OES geometrical layout together with a suitable pixel representation. Even with a limited number of 14 lines of sight (LoSs), the plasma emissivity distribution expected on the ELISE source can be successfully reconstructed. In particular, asymmetries in the emissivity pattern can be detected and reproduced with low errors. A systematic investigation of different geometrical layouts of the LoSs as well as of the pixel arrangements has been carried out, and a final configuration has been identified. Noise on the simulated experimental spectroscopic measurements has been tested, confirming the reliability of the adopted tomographic tools for the plasma emissivity reconstructions of the source plasma in ELISE with the actual OES diagnostic system. (paper)

  3. Basic design of the beam diagnostic device and proposal of a new electrostatic optical element

    Energy Technology Data Exchange (ETDEWEB)

    Hanashima, Susumu [Japan Atomic Energy Research Inst., Tokyo (Japan)

    2001-02-01

    The basic design completed of a beam diagnostic device, which indicates, among others, the phase space regions acceptable by the beams, and density distributions in the phase space as well. The measurement is made using two deflectors and two apertures. (M. Tanaka)

  4. Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Mário L. R. Monteiro

    2008-01-01

    Full Text Available OBJECTIVES: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index, calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. RESULTS: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy met the inclusion criteria for the study. The mean Barrett's index values (± SD were 64.47% ± 6.06% and 49.44% ± 10.94%in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy.

  5. Optical Sideband Generation: a Longitudinal Electron Beam Diagnostic Beyond the Laser Bandwidth Resolution Limit

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence Berkeley National Laboratory; Tilborg, J. van; Matlis, N. H.; Plateau, G. R.; Leemans, W. P.

    2010-06-01

    Electro-optic sampling (EOS) is widely used as a technique to measure THz-domain electric field pulses such asthe self-fields of femtosecond electron beams. We present an EOS-based approach for single-shot spectral measurement that excels in simplicity (compatible with fiber integration) and bandwidth coverage (overcomes the laser bandwidth limitation), allowing few-fs electron beams or single-cycle THz pulses to be characterized with conventional picosecond probes. It is shown that the EOS-induced optical sidebands on the narrow-bandwidth optical probe are spectrally-shifted replicas of the THz pulse. An experimental demonstration on a 0-3 THz source is presented.

  6. Glaucoma Diagnostic Capabilities of Foveal Avascular Zone Parameters Using Optical Coherence Tomography Angiography According to Visual Field Defect Location.

    Science.gov (United States)

    Kwon, Junki; Choi, Jaewan; Shin, Joong Won; Lee, Jiyun; Kook, Michael S

    2017-12-01

    To assess the diagnostic ability of foveal avascular zone (FAZ) parameters to discriminate glaucomatous eyes with visual field defects (VFDs) in different locations (central vs. peripheral) from normal eyes. Totally, 125 participants were separated into 3 groups: normal (n=45), glaucoma with peripheral VFD (PVFD, n=45), and glaucoma with central VFD (CVFD, n=35). The FAZ area, perimeter, and circularity and parafoveal vessel density were calculated from optical coherence tomography angiography images. The diagnostic ability of the FAZ parameters and other structural parameters was determined according to glaucomatous VFD location. Associations between the FAZ parameters and central visual function were evaluated. A larger FAZ area and longer FAZ perimeter were observed in the CVFD group than in the PVFD and normal groups. The FAZ area, perimeter, and circularity were better in differentiating glaucomatous eyes with CVFDs from normal eyes [areas under the receiver operating characteristic curves (AUC), 0.78 to 0.88] than in differentiating PVFDs from normal eyes (AUC, 0.51 to 0.64). The FAZ perimeter had a similar AUC value to the circumpapillary retinal nerve fiber layer and macular ganglion cell-inner plexiform layer thickness for differentiating eyes with CVFDs from normal eyes (all P>0.05, the DeLong test). The FAZ area was significantly correlated with central visual function (β=-112.7, P=0.035, multivariate linear regression). The FAZ perimeter had good diagnostic capability in differentiating glaucomatous eyes with CVFDs from normal eyes, and may be a potential diagnostic biomarker for detecting glaucomatous patients with CVFDs.

  7. Diagnostic imaging capabilities of the Ocelot -Optical Coherence Tomography System, ex-vivo evaluation and clinical relevance

    International Nuclear Information System (INIS)

    Dohad, Suhail; Shao, John; Cawich, Ian; Kankaria, Manish; Desai, Arjun

    2015-01-01

    Optical coherence tomography (OCT) is a high-resolution sub-surface imaging modality using near-infrared light to provide accurate and high contrast intra-vascular images. This enables accurate assessment of diseased arteries before and after intravascular intervention. This study was designed to corroborate diagnostic imaging equivalence between the Ocelot and the Dragonfly OCT systems with regards to the intravascular features that are most important in clinical management of patients with atherosclerotic vascular disease. These intravascular features were then corroborated in vivo during treatment of peripheral arterial disease (PAD) pathology using the Ocelot catheter. In order to compare the diagnostic information obtained by Ocelot (Avinger Inc., Redwood City, CA) and Dragonfly (St. Jude Medical, Minneapolis, MN) OCT systems, we utilized ex-vivo preparations of arterial segments. Ocelot and Dragonfly catheters were inserted into identical cadaveric femoral peripheral arteries for image acquisition and interpretation. Three independent physician interpreters assessed the images to establish accuracy and sensitivity of the diagnostic information. Histologic evaluation of the corresponding arterial segments provided the gold standard for image interpretation. In vivo clinical images were obtained during therapeutic interventions that included crossing of peripheral chronic total occlusions (CTOs) using the Ocelot catheter. Strong concordance was demonstrated when matching image characteristics between both OCT systems and histology. The Dragonfly and Ocelot system’s vessel features were interpreted with high sensitivity (91.1–100 %) and specificity (86.7–100 %). Inter-observer concordance was documented with excellent correlation across all vessel features. The clinical benefit that the Ocelot OCT system provided was demonstrated by comparable procedural images acquired at the point of therapy. The study demonstrates equivalence of image acquisition and

  8. Optical fluctuation measurements of turbulence using a diagnostic beam on Phaedrus-T

    International Nuclear Information System (INIS)

    Evensen, H.; Brouchous, D.; Diebold, D.; Doczy, M.; Fonck, R.J.; Nolan, D.

    1992-01-01

    Plasma density turbulence has been measured with the beam emission spectroscopy (BES) diagnostic system, using a low-power neutral beam with He 0 and H 0 as beam species. In general, He 0 (588 nm) provided the best signal-to-noise ratio due to its lower edge plasma background interference. Simultaneous measurements of edge density fluctuations have been made with BES and Langmuir probes; the spectra are seen to be essentially identical, and the fluctuation amplitudes from both diagnostics are in close agreement. A poloidal coherence length of about 2--4 cm was observed. Radial propagation of modes was not seen, but a lab-frame poloidal phase velocity at r/a=0.77 of about 7x10 5 cm/s in the electron diamagnetic direction was observed, corresponding to m=8--75 kHz

  9. Laser ablation method for cleaning of mirror surfaces for optical diagnostic systems at the ITER

    International Nuclear Information System (INIS)

    Aleksandrova, A.S.; Kuznetsov, A.P.; Gubskij, K.L.; Petrovskij, V.N.; Savelov, A.S.; Shtamm, V.G.; Buzhinskij, O.I.

    2012-01-01

    The possibility of cleaning metallic mirrors from films with complex composition by pulsed radiation from a fiber laser has been experimentally examined. It has been shown that the high initial reflection characteristics of optical elements can be recovered by choosing regimes of the action of radiation on the surface with a deposited film [ru

  10. Optical spectroscopy: current advances and future applications in cancer diagnostics and therapy

    NARCIS (Netherlands)

    Evers, Daniel; Evers, D.J.; Hendriks, B.; Lucassen, G.W.; Lucassen, Gerald; Ruers, Theo J.M.

    2012-01-01

    Optical spectroscopy (OS) is a tissue-sensing technique that could enhance cancer diagnosis and treatment in the near future. With OS, tissue is illuminated with a selected light spectrum. Different tissue types can be distinguished from each other based on specific changes in the reflected light

  11. In situ optical diagnostic for monitoring or control of sodium diffusion in photovoltaics manufacturing

    Science.gov (United States)

    Li, Jian; Levi, Dean; Contreras, Miguel; Glynn, Stephen

    2015-09-15

    A method of fabricating a photovoltaic device 100, includes the steps of providing a glass substrate 102, depositing a molybdenum layer 104 on a surface of the glass substrate, directing light through the glass substrate to the near-substrate region of the molybdenum layer 206, detecting an optical property of the near-substrate region of the molybdenum layer after interaction with the incident light 208 and determining a density of the near-substrate region of the molybdenum layer from the detected optical property 210. A molybdenum deposition parameter may be controlled based upon the determined density of the near-substrate region of the molybdenum layer 218. A non-contact method measures a density of the near-substrate region of a molybdenum layer and a deposition chamber 300.

  12. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    International Nuclear Information System (INIS)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-01-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm −1 , while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm −1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases. (letter)

  13. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    Science.gov (United States)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-06-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm-1, while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm-1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases.

  14. Optical Diagnostic Characterization of High-Power Hall Thruster Wear and Operation

    Science.gov (United States)

    Williams, George J., Jr.; Soulas, George C.; Kamhawi, Hani

    2012-01-01

    Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power Hall thruster operation. Specifically, actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, and discharge current. In addition, the technique is demonstrated on metallic coupons embedded in the walls of the HiVHAc EM thruster. The OES technique captured the overall trend in the erosion of the coupons which boosts credibility in the method since there are no data to which to calibrate the erosion rates of high-power Hall thrusters. The boron signals are shown to trend linearly with discharge voltage for a fixed discharge current as expected. However, the boron signals of the higher-power NASA 300M and NASA 457Mv2 trend with discharge current and show an unexpectedly weak to inverse dependence on discharge voltage. Electron temperatures measured optically in the near-field plume of the thruster agree well with Langmuir probe data. However, the optical technique used to determine Te showed unacceptable sensitivity to the emission intensities. Near-field, single-frequency imaging of the xenon neutrals is also presented as a function of operating condition for the NASA 457 Mv2.

  15. FOREX-A Fiber Optics Diagnostic System For Study Of Materials At High Temperatures And Pressures

    Science.gov (United States)

    Smith, D. E.; Roeske, F.

    1983-03-01

    We have successfully fielded a Fiber Optics Radiation EXperiment system (FOREX) designed for measuring material properties at high temperatures and pressures on an underground nuclear test. The system collects light from radiating materials and transmits it through several hundred meters of optical fibers to a recording station consisting of a streak camera with film readout. The use of fiber optics provides a faster time response than can presently be obtained with equalized coaxial cables over comparable distances. Fibers also have significant cost and physical size advantages over coax cables. The streak camera achieves a much higher information density than an equivalent oscilloscope system, and it also serves as the light detector. The result is a wide bandwidth high capacity system that can be fielded at a relatively low cost in manpower, space, and materials. For this experiment, the streak camera had a 120 ns time window with a 1.2 ns time resolution. Dynamic range for the system was about 1000. Beam current statistical limitations were approximately 8% for a 0.3 ns wide data point at one decade above the threshold recording intensity.

  16. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G; Meglinski, I V

    2014-01-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  17. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  18. DIAGNOSTICS FOR ION BEAM DRIVEN HIGH ENERGY DENSITY PHYSICS EXPERIMENTS

    International Nuclear Information System (INIS)

    Bieniosek, F.M.; Henestroza, E.; Lidia, S.; Ni, P.A.

    2010-01-01

    Intense beams of heavy ions are capable of heating volumetric samples of matter to high energy density. Experiments are performed on the resulting warm dense matter (WDM) at the NDCX-I ion beam accelerator. The 0.3 MeV, 30-mA K + beam from NDCX-I heats foil targets by combined longitudinal and transverse neutralized drift compression of the ion beam. Both the compressed and uncompressed parts of the NDCX-I beam heat targets. The exotic state of matter (WDM) in these experiments requires specialized diagnostic techniques. We have developed a target chamber and fielded target diagnostics including a fast multi-channel optical pyrometer, optical streak camera, laser Doppler-shift interferometer (VISAR), beam transmission diagnostics, and high-speed gated cameras. We also present plans and opportunities for diagnostic development and a new target chamber for NDCX-II.

  19. A model for the Lin-Shu type density-wave structure of our Galaxy: Line-of-sight and transverse-longitudinal velocities of 242 optically visible open clusters

    Science.gov (United States)

    Griv, E.; Jiang, I.-G.

    2015-02-01

    In this paper, the fourth in a series, we examine again one of the implications of the Lin-Shu density-wave theory, specifically, the noncircular systematic motion of the Galactic objects. Our previous investigation is extended by analyzing simultaneously both the line-of-sight and transversal velocities of a sample of open clusters for which velocities, distances and ages are available. The ordinary equations of the Oort-Lindblad theory of galactic differential rotation are used. The minor effects caused by the two-dimensional tightly-wound density waves are also taken into account. The published data of 242 currently known optically visible clusters having distances rsight and transversal along the Galactic longitude velocities are nearly equal. We argue that the resemblance of these Galactic wave structures is so remarkable that no doubt is felt as to the theory's truth with respect to these data. The results obtained allow us to conclude that several low-m trailing density-wave patterns with different number of spiral arms m (say, m=1, 2, 3, and 4), pitch angles (about 5o, 8o, 11o, and 14o, respectively) and amplitudes of the perturbed gravitational potential may coexist in the Galaxy. The latter suggests the asymmetric multiarm, not well-organized (``flocculent'') spiral structure of the system. In memory of Professors Alexei M. Fridman (1940-2010) and Chi Yuan (1937-2008)

  20. Improvements to a high-frequency fiber-optic system for plasma diagnostics

    International Nuclear Information System (INIS)

    Ogle, J.W.; Lyons, P.B.; Looney, L.; Hocker, L.; Nelson, M.A.; Zagarino, P.A.; Davies, T.J.; Simmons, R.D.; Selk, R.; Hopkins, B.

    1981-01-01

    A system for high-frequency recording of plasma diagnostics has previously been reported. Substantial improvements have been made in the system response, dynamic range, and calibration of the system. Plastic-clad silica fiber is used as a radiation-to-light converter using the Cerenkov process. A spectral equalizer device is used to compensate for the material dispersion in the fiber, increasing the frequency response (approx. = 1 GHz-km) and the dynamic range (a factor of > 20 over a FWHM 1 nm, 50% transmitting interference filter). The calibration system uses a pulsed injection laser diode (< 100 ps FWHM) injected into the fiber at the radiation end of the fiber and detected by a microchannel plate photomultiplier tube on the recording end. The injection laser diode is triggered by a synchronous trigger delay unit, which also triggers a sampling or real time scope after as much as 10 μs delay with < 50 ps jitter. The system improvements are described in detail and the utility of these components in other plasma diagnostic systems is discussed

  1. Development of time-resolved optical measurement and diagnostic system for parameters of high current and pulsed electron beam

    International Nuclear Information System (INIS)

    Jiang Xiaoguo; Wang Yuan; Yang Guojun; Xia Liansheng; Li Hong; Zhang Zhuo; Liao Shuqing; Shi Jinshui

    2013-01-01

    The beam parameters measurement is the most important work for the study of linear induction accelerator(LIA). The beam parameters are important to evaluate the character of the beam. The demands of beam parameters measurement are improving while the development of accelerator is improving. The measurement difficulty feature higher time-resolved ability, higher spatial resolution, larger dynamic range and higher intuitionistic view data. The measurement technology of beam spot, beam emittance, beam energy have been developed for the past several years. Some high performance equipment such as high speed framing camera are developed recently. Under this condition, the relative integrated optical measurement and diagnostic system for the beam parameters is developed based on several principles. The system features time-resolved ability of up to 2 ns, high sensitivity and large dynamic range. The processing program is compiled for the data process and the local real-time process is reached. The measurement and diagnostic system has provided full and accurate data for the debug work and has been put into applications. (authors)

  2. X-ray optical diagnostic of laser produced plasmas for nuclear fusion and X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Butzbach, R.

    2001-07-01

    In the present work, the conception, design and appliance of toroidally bent crystals for the X-ray optical diagnostics of laser produced plasmas is discussed. The first part of this work deals with the development, design and characterization of an X-Ray microscope for the observation of Rayleigh-Taylor instabilities, which act against the confinement and ignition of the fuel in the inertial confinement fusion process. The aim of the second part of the present work was the diagnostic of the lasing medium for amplified spontaneous emission close to the water window. For this purpose, an one-dimensionally (1-D) imaging X-ray spectrometer based on toroidally bent quartz crystals was developed for the observation of the Ni-like 4f-3d transition of Yb, Hf, Ta, and W ions, which should be related to the amplified 4d-4p emission, since the 4f niveau is very close to the 4d niveau. Thus, the 4f-3d transition can serve as an indicator for the population of the 4d niveau. (orig.)

  3. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beama)

    Science.gov (United States)

    Froula, D. H.; Boni, R.; Bedzyk, M.; Craxton, R. S.; Ehrne, F.; Ivancic, S.; Jungquist, R.; Shoup, M. J.; Theobald, W.; Weiner, D.; Kugland, N. L.; Rushford, M. C.

    2012-10-01

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)], 10.1051/jp4:2006133015. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (˜1 - μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 104 with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  4. Transverse colon cancer with Krukenberg tumor : A case report

    OpenAIRE

    東門, 敦子; 松原, 洋孝; 下地, 英明; 伊佐, 勉; 濱安, 俊吾; 仲地, 厚; 宮里, 浩; 白石, 祐之; 武藤, 良弘; Tomon, Atsuko; Matsubara, Hirotaka; Shimoji, Hideaki; Isa, Tsutomu; Nakachi, Atsushi; Miyazato, Hiroshi

    1999-01-01

    A case of Krukenberg tumor in a 30-year-old woman with transverse colon cancer is reported herein. The patient was found to have bilateral ovarian tumors and abnormal elevation of serum CEA at a community hospital. Subsequently, she was referred to the University Hospital for further work. Diagnostic examinations including US, CT and colonoscopy demonstrated transverse colon cancer and bilateral ovarian tumors. Exploratory laparotomy showed the growth of transverse colon cancer over the perit...

  5. Applications of optical fibers and miniature photonic elements in medical diagnostics

    Science.gov (United States)

    Blaszczak, Urszula; Gilewski, Marian; Gryko, Lukasz; Zajac, Andrzej; Kukwa, Andrzej; Kukwa, Wojciech

    2014-05-01

    Construction of endoscopes which are known for decades, in particular in small devices with the diameter of few millimetres, are based on the application of fibre optic imaging bundles or bundles of fibers in the illumination systems (usually with a halogen source). Cameras - CCD and CMOS - with the sensor size of less than 5 mm emerging commercially and high power LED solutions allow to design and construct modern endoscopes characterized by many innovative properties. These constructions offer higher resolution. They are also relatively cheaper especially in the context of the integration of the majority of the functions on a single chip. Mentioned features of the CMOS sensors reduce the cycle of introducing the newly developed instruments to the market. The paper includes a description of the concept of the endoscope with a miniature camera built on the basis of CMOS detector manufactured by Omni Vision. The set of LEDs located at the operator side works as the illuminating system. Fibre optic system and the lens of the camera are used in shaping the beam illuminating the observed tissue. Furthermore, to broaden the range of applications of the endoscope, the illuminator allows to control the spectral characteristics of emitted light. The paper presents the analysis of the basic parameters of the light-and-optical system of the endoscope. The possibility of adjusting the magnifications of the lens, the field of view of the camera and its spatial resolution is discussed. Special attention was drawn to the issues related to the selection of the light sources used for the illumination in terms of energy efficiency and the possibility of providing adjusting the colour of the emitted light in order to improve the quality of the image obtained by the camera.

  6. Analysis of heat and mass transfers in two-phase flow by coupling optical diagnostic techniques

    International Nuclear Information System (INIS)

    Lemaitre, P.; Porcheron, E.

    2008-01-01

    During the course of a hypothetical accident in a nuclear power plant, spraying might be actuated to reduce static pressure in the containment. To acquire a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, non-intrusive optical measurements have to be carried out simultaneously on both phases. The coupling of global rainbow refractometry with out-of-focus imaging and spontaneous Raman scattering spectroscopy allows us to calculate the local Spalding parameter B M , which is useful in describing heat transfer associated with two-phase flow. (orig.)

  7. Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, A. P., E-mail: APKuznetsov@mephi.ru; Alexandrova, A. S. [National Research Nuclear University MEPhI (Russian Federation); Buzhinsky, O. I. [State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research (Russian Federation); Gubskiy, K. L.; Kazieva, T. V.; Savchenkov, A. V. [National Research Nuclear University MEPhI (Russian Federation); Tugarinov, S. N. [State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research (Russian Federation)

    2015-12-15

    The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10{sup 7} W/cm{sup 2}. The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant.

  8. Analysis of heat and mass transfers in two-phase flow by coupling optical diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lemaitre, P.; Porcheron, E. [Institut de Radioprotection et de Surete Nucleaire, Saclay (France)

    2008-08-15

    During the course of a hypothetical accident in a nuclear power plant, spraying might be actuated to reduce static pressure in the containment. To acquire a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, non-intrusive optical measurements have to be carried out simultaneously on both phases. The coupling of global rainbow refractometry with out-of-focus imaging and spontaneous Raman scattering spectroscopy allows us to calculate the local Spalding parameter B{sub M}, which is useful in describing heat transfer associated with two-phase flow. (orig.)

  9. Feasibility of Optical Transition Radiation Imaging for Laser-driven Plasma Accelerator Electron-Beam Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Rule, D. W. [Unlisted, US, MD; Downer, M. C. [Texas U.

    2017-10-09

    We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/γ and beam sizes to be determined at the micron level. Analytical modeling results indicate the feasibility of using these OTR techniques for the LPA applications.

  10. Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

    International Nuclear Information System (INIS)

    Kuznetsov, A. P.; Alexandrova, A. S.; Buzhinsky, O. I.; Gubskiy, K. L.; Kazieva, T. V.; Savchenkov, A. V.; Tugarinov, S. N.

    2015-01-01

    The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10 7 W/cm 2 . The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant

  11. Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers

    International Nuclear Information System (INIS)

    McBride, J. W.; Balestrero, A.; Tribulato, G.; Ghezzi, L.; Cross, K. J.

    2010-01-01

    An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10 6 images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

  12. Self-referencing Mach-Zehnder interferometer as a laser system diagnostic: Active and adaptive optical systems

    International Nuclear Information System (INIS)

    Feldman, M.; Mockler, D.J.; English, R.E. Jr.; Byrd, J.L.; Salmon, J.T.

    1991-01-01

    We are incorporating a novel self-referencing Mach-Zehnder interferometer into a large scale laser system as a real time, interactive diagnostic tool for wavefront measurement. The instrument is capable of absolute wavefront measurements accurate to better than λ/10 pv over a wavelength range > 300 nm without readjustment of the optical components. This performance is achieved through the design of both refractive optics and catadioptric collimator to achromatize the Mach-Zehnder reference arm. Other features include polarization insensitivity through the use of low angles of incidence on all beamsplitters as well as an equal path length configuration that allows measurement of either broad-band or closely spaced laser-line sources. Instrument accuracy is periodically monitored in place by means of a thermally and mechanically stable wavefront reference source that is calibrated off-line with a phase conjugate interferometer. Video interferograms are analyzed using Fourier transform techniques on a computer that includes dedicated array processor. Computer and video networks maintain distributed interferometers under the control of a single analysis computer with multiple user access. 7 refs., 11 figs

  13. Application of optical fluctuation diagnostics to transport studies in high temperature tokamak plasmas

    International Nuclear Information System (INIS)

    Fonck, R.J.

    1991-01-01

    First data was obtained from the TFTR BES system in May 1990, after the prototype 4-channel system with photomultiplier detectors from PBX-M was transferred to the TFTR Hot Cell. The system was expanded to 16 spatial channels during the Summer 1990 run period, and data of interest was obtained near the end of the run in October 1990. The most attention has been given to a radial profile data set obtained for an L-mode plasma condition in TFTR, where we characterized the nature of the long-wavelength turbulence seen by the BES diagnostic. We summarize here highlights of the initial run with BES or TFTR. We also give a progress report on support activities at UW

  14. Time-Resolved Spectroscopy Diagnostic of Laser-Induced Optical Breakdown

    Directory of Open Access Journals (Sweden)

    Christian G. Parigger

    2010-01-01

    Full Text Available Transient laser plasma is generated in laser-induced optical breakdown (LIOB. Here we report experiments conducted with 10.6-micron CO2 laser radiation, and with 1.064-micron fundamental, 0.532-micron frequency-doubled, 0.355-micron frequency-tripled Nd:YAG laser radiation. Characterization of laser induced plasma utilizes laser-induced breakdown spectroscopy (LIBS techniques. Atomic hydrogen Balmer series emissions show electron number density of 1017 cm−3 measured approximately 10 μs and 1 μs after optical breakdown for CO2 and Nd:YAG laser radiation, respectively. Recorded molecular recombination emission spectra of CN and C2 Swan bands indicate an equilibrium temperature in excess of 7000 Kelvin, inferred for these diatomic molecules. Reported are also graphite ablation experiments where we use unfocused laser radiation that is favorable for observation of neutral C3 emission due to reduced C3 cation formation. Our analysis is based on computation of diatomic molecular spectra that includes accurate determination of rotational line strengths, or Hönl-London factors.

  15. Electron shower transverse profile measurement

    International Nuclear Information System (INIS)

    Lednev, A.A.

    1993-01-01

    A method to measure the shower transverse profile is described. Calibration data of the lead-glass spectrometer GAMS collected in a wide electron beam without any additional coordinate detector are used. The method may be used for the measurements in both cellular- and projective-type spectrometers. The results of measuring the 10 GeV electron shower profile in the GAMS spectrometer, without optical grease between the lead-glass radiators and photomultipliers, are approximated with an analytical function. The estimate of the coordinate accuracy is obtained. 5 refs., 8 figs

  16. TRANSVERSELY POLARIZED Λ PRODUCTION

    International Nuclear Information System (INIS)

    BORER, D.

    2000-01-01

    Transversely polarized Λ production in hard scattering processes is discussed in terms of a leading twist T-odd fragmentation function which describes the fragmentation of an unpolarized quark into a transversely polarized Λ. We focus on the properties of this function and its relevance for the RHIC and HERMES experiments

  17. Transversely Compressed Bonded Joints

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Schmidt, Jacob Wittrup; Stang, Henrik

    2012-01-01

    The load capacity of bonded joints can be increased if transverse pressure is applied at the interface. The transverse pressure is assumed to introduce a Coulomb-friction contribution to the cohesive law for the interface. Response and load capacity for a bonded single-lap joint was derived using...

  18. Transverse Localization of Light

    NARCIS (Netherlands)

    Raedt, Hans De; Lagendijk, Ad; Vries, Pedro de

    1989-01-01

    We study the propagation of light through a semi-infinite medium with transverse disorder (that is, disorder in two directions only). We show that such a system exhibits strong two-dimensional localization by demonstrating that on propagation a beam expands until the transverse localization length

  19. 'Optical' soft x-ray arrays for fluctuation diagnostics in magnetic fusion energy experiments

    International Nuclear Information System (INIS)

    Delgado-Aparicio, L.F.; Stutman, D.; Tritz, K.; Finkenthal, M.; Kaita, R.; Roquemore, L.; Johnson, D.; Majeski, R.

    2004-01-01

    We are developing large pixel count, fast (≥100 kHz) and continuously sampling soft x-ray (SXR) array for the diagnosis of magnetohydrodynamics (MHD) and turbulent fluctuations in magnetic fusion energy plasmas. The arrays are based on efficient scintillators, high thoughput multiclad fiber optics, and multichannel light amplification and integration. Compared to conventional x-ray diode arrays, such systems can provide vastly increased spatial coverage, and access to difficult locations with small neutron noise and damage. An eight-channel array has been built using columnar CsI:Tl as an SXR converter and a multianode photomultiplier tube as photoamplifier. The overall system efficiency is measured using laboratory SXR sources, while the time response and signal-to-noise performance have been evaluated by recording MHD activity from the spherical tori (ST) Current Drive Experiment-Upgrade and National Spherical Torus Experiment, both at Princeton Plasma Physics Laboratory

  20. Study of the Plasma Evolution in the PF-1000 Device by Means of Optical Diagnostics

    International Nuclear Information System (INIS)

    Kasperczuk, A.; Kumar, R.; Miklaszewski, R.; Paduch, M.; Pisarczyk, T.; Scholz, M.; Tomaszewski, K.

    2002-01-01

    Investigation of a plasma evolution was carried out in a PF-1000 device with the following parameters: diameter of the inner electrode -24.4 cm, diameter of the outer one -36.8 cm, charging voltage in the range of 30-40 kV and deuterium pressure in the range of 1-5 1 To study the evolution of the plasma, an optical frame camera and YAGlaser shadowgraphy, both with exposure times of about 1 ns, were employed. Among the cases analyzed of plasma focus discharges, two types of plasma sheath disturbance can be distinguished: type I - classical MHD m = 0 instability (a wave with four maxima in the main), type 11 - singular great scale disturbance. On the basis of the plasma images, the dynamics of the plasma sheath, characteristic periods of the plasma evolution and plasma dimensions were determined. In order to reconstruct the spatial distribution of the electron density a special method was prepared

  1. Techniques for fabricating an infrared optical pyrometry system for pulsed electron beam diagnostics

    International Nuclear Information System (INIS)

    Ouellette, A.L.

    1976-01-01

    A description is given of an infrared optical pyrometry system which was designed to make fast time resolved temperature measurements. The purpose of this equipment is to determine the amount of energy from an electron beam or some other type of pulsed energy deposition that is absorbed in a target. The system is capable of measuring energy deposition levels up to 4000 J/g in carbon, which corresponds to a graphite target temperature of 2200 0 C. Methods of fabrication, alignment, and calibration are presented. The measurement of absorbed energy in a target as a function of position and depth is discussed as a possible application, and several measurements are described which permit a comparison of results from this system with those taken by other methods

  2. A High-Speed Optical Diagnostic that uses Interference Filters to Measure Doppler Shifts

    International Nuclear Information System (INIS)

    Paul, S.F.; Cates, C.; Mauel, M.; Maurer, D.; Navratil, G.; Shilov, M.

    2004-01-01

    A high-speed, non-invasive velocity diagnostic has been developed for measuring plasma rotation. The Doppler shift is determined by employing two detectors that view line emission from the identical volume of plasma. Each detector views through an interference filter having a passband that varies linearly with wavelength. One detector views the plasma through a filter whose passband has a negative slope and the second detector views through one with a positive slope. Because each channel views the same volume of plasma, the ratio of the amplitudes is not sensitive to variations in plasma emission. With suitable knowledge of the filter characteristics and the relative gain, the Doppler shift is readily obtained in real time from the ratio of two channels without needing a low throughput spectrometer. The systematic errors--arising from temperature drifts, stability, and frequency response of the detectors and amplifiers, interference filter linearity, and ability to thoroughly homogenize the light from the fiber bundle--can be characterized well enough to obtain velocity data with + or - 1 km/sec with a time resolution of 0.3 msec

  3. Parametric Transverse Patterns in Broad Aperture Lasers

    DEFF Research Database (Denmark)

    Grigorieva, E.V.; Kashchenko, S.A.; Mosekilde, Erik

    1998-01-01

    Parametrically generated optical patterns are investigated for finite and large-scale transverse aperture lasers. Standing and rotating patterns as well as periodic and chaotic pattern alternations are described in the framework of the amplitude equation formalism. Sensitive dependence...... on the geometrical size of the system is demonstrated even in the case of large-scale systems....

  4. Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

    Science.gov (United States)

    Zabotnov, S. V.; Kashaev, F. V.; Shuleiko, D. V.; Gongalsky, M. B.; Golovan, L. A.; Kashkarov, P. K.; Loginova, D. A.; Agrba, P. D.; Sergeeva, E. A.; Kirillin, M. Yu

    2017-07-01

    The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700-1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150-300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent.

  5. Optical diagnostics to adjust burners. Een optische diagnostiek voor het instellen van branders

    Energy Technology Data Exchange (ETDEWEB)

    Braam, A L.H.; Hulshof, H J.M.; De Jongh, W [NV KEMA, Arnhem (Netherlands)

    1991-05-01

    The most efficient method to reduce nitrogen oxides in a natural gas flame or a coal flame is a correct adjustment of the burners. A newly developed optical method to measure the temperature distribution in the flame is discussed. KEMA (a Dutch Electrotechnical Equipment Testing Agency) developed the measuring method to control the combustion process in each burner of a natural gas- or coal-fired power plant for NOx formation for a constant energy production, and for the stability of the combustion. By means of data from the temperature distribution measurements some important parameters concerning NOx formation can be determined. Attention is paid to several active and passive spectroscopic methods to measure temperatures in flames. Passive spectroscopy is considered to be the best measuring method. Concentrations of radicals (CH, CN, NH) and temperature distribution are determined by means of a spectroheliograph and a camera, flame temperatures are measured by means of metal tracers. Experimental measurements carried out in the Flevo plant (EPON) are discussed. 8 figs.

  6. The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review

    Directory of Open Access Journals (Sweden)

    Monika Machoy

    2017-01-01

    Full Text Available Optical coherence tomography provides sections of tissues in a noncontact and noninvasive manner. The device measures the time delay and intensity of the light scattered or reflected from biological tissues, which results in tomographic imaging of their internal structure. This is achieved by scanning tissues at a resolution ranging from 1 to 15 μm. OCT enables real-time in situ imaging of tissues without the need for biopsy, histological procedures, or the use of X-rays, so it can be used in many fields of medicine. Its properties are not only particularly used in ophthalmology, in the diagnosis of all layers of the retina, but also increasingly in cardiology, gastroenterology, pulmonology, oncology, and dermatology. The basic properties of OCT, that is, noninvasiveness and low wattage of the used light, have also been appreciated in analytical technology by conservators, who use it to identify the quality and age of paintings, ceramics, or glass. Recently, the OCT technique of visualization is being tested in different fields of dentistry, which is depicted in the article.

  7. Electromagnetic diagnostics of ECR-Ion Sources plasmas: optical/X-ray imaging and spectroscopy

    Science.gov (United States)

    Mascali, D.; Castro, G.; Altana, C.; Caliri, C.; Mazzaglia, M.; Romano, F. P.; Leone, F.; Musumarra, A.; Naselli, E.; Reitano, R.; Torrisi, G.; Celona, L.; Cosentino, L. G.; Giarrusso, M.; Gammino, S.

    2017-12-01

    Magnetoplasmas in ECR-Ion Sources are excited from gaseous elements or vapours by microwaves in the range 2.45-28 GHz via Electron Cyclotron Resonance. A B-minimum, magnetohydrodynamic stable configuration is used for trapping the plasma. The values of plasma density, temperature and confinement times are typically ne= 1011-1013 cm-3, 01 eVSilicon Drift detectors with high energy resolution of 125 eV at 5.9 keV have been used for the characterization of plasma emission at 02optical range and spectroscopic measurements have been carried out. Relative abundances of H/H2 atoms/molecules in the plasmas have been measured for different values of neutral pressure, microwave power and magnetic field profile (they are critical for high-power proton sources).

  8. Diagnostic capability of optic nerve head rim width and retinal nerve fiber thickness in open-angle glaucoma.

    Science.gov (United States)

    Di Staso, Silvio; Agnifili, Luca; Di Staso, Federico; Climastone, Hilary; Ciancaglini, Marco; Scuderi, Gian Luca

    2018-03-01

    This study was performed to test the diagnostic capability of the minimum rim width compared to peripapillary retinal nerve fiber layer thickness in patients with glaucoma. A case control, observer masked study, was conducted. Minimum rim width and retinal nerve fiber layer thickness were assessed using the patient-specific axis traced between fovea-to-Bruch's membrane opening center axis. For both minimum rim width and retinal nerve fiber layer thickness, the regionalization in six sectors (nasal, superior-nasal, superior-temporal, temporal, inferior-temporal, and inferior-nasal) was analyzed. Eyes with at least one sector with value below the 5% or 1% normative limit of the optical coherence tomography normative database were classified as glaucomatous. The area under the receiver operator characteristic curve, the accuracy, sensitivity, specificity, and predictive positive and negative values were calculated for both minimum rim width and retinal nerve fiber layer thickness. A total of 118 eyes of 118 Caucasian subjects (80 eyes with open-angle glaucoma and 38 control eyes) were enrolled in the study. Accuracy, sensitivity, and specificity were 79.7%, 77.5%, and 84.2%, respectively, for minimum rim width and 84.7%, 82.5%, and 89.5% for retinal nerve fiber layer thickness. The positive predictive values were 0.91% and 0.94% for minimum rim width and retinal nerve fiber layer thickness, respectively, whereas the negative predictive values were 0.64% and 0.70%. The area under the receiver operator characteristic curve was 0.892 for minimum rim width and 0.938 for retinal nerve fiber layer thickness. Our results indicated that the sector analysis based on Bruch's membrane opening and fovea to disk alignment is able to detect glaucomatous defects, and that Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness showed equivalent diagnostic ability.

  9. Isolated Transverse Sacrum Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Cemil Kavalci

    2011-01-01

    Full Text Available Sacral fracture commonly results from high-energy trauma. Most insufficiency fractures of the sacrum are seen in women after the age of 70. Fractures of the sacrum are rare and generally combined with a concomitant pelvic fracture. Transverse sacral fractures are even less frequent which constitute only 3–5% of all sacral fractures. This type of fractures provide a diagnostic challenge. We report a unique case of isolated transverse fracture of sacrum in a young man sustained low-energy trauma. The patient presented to our emergency department after several hours of injury, and diagnosed by clinical features and roentgenogram findings.

  10. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of

  11. Diagnostics for high-brightness beams

    International Nuclear Information System (INIS)

    Shafer, R.E.

    1990-01-01

    Special techniques are required for beam diagnostics on high-brightness particle beams. Examples of high-brightness beams include low-emittance proton linacs (either pulsed or CW), electron linacs suitable for free-electron-laser applications, and future linear colliders. Non-interceptive and minimally-interceptive techniques for measuring beam current, position, profile, and transverse and longitudinal emittance will be reviewed. Included will be stripline, wire scanner, laser neutralization, beam-beam scattering, interceptive microgratings, spontaneous emission, optical transition radiation, and other techniques. 24 refs

  12. Insights into the different effects of Tumble motion, using couplings of optical diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Mansion, T.; Floch, A.; Croteau, D. [Renault S.A., Lardy (France); Tellier, A. [NSA Rouen (France)

    2006-07-01

    Optimization of both engine out emissions during cold start and fuel consumption at low load in MPI gasoline engines still remains an important goal. One of the ways to reach this goal and also to meet future tighter CAFE standards, which means to reduce CO{sub 2} vehicle emissions in Europe, is to control combustion. This might include dilution using internal residual gas and strong aerodynamic levels (e.g. tumble motion) in order to stand this dilution. High Tumble enables very late spark advances for cold start conditions, which is favorable to catalyst warm-up, whereas an improvement of combustion stability for low load operating points can be observed. These benefits are commonly explained by the fact that Tumble is favorable, on one hand, to mixture formation and, on the other hand, to the production of turbulence during the end of the compression, for ignition and for flame propagation. This paper presents an innovative approach aiming at a better knowledge of Tumble contributions to combustion stability and engine emissions during cold start and for low load operating points. The study was led under firing conditions on optical single cylinder engine, highly representative of 1.2L 16V engine (4 cylinders engine, naturally aspirated), to explain results observed on multi-cylinder engine. As a first stage, Particle Image Velocimetry (PIV) has been used to compare two different airflow structures. Next, Fuel Air Ratio Laser Induced Exciplex Fluorescence (FARLIEF) has been handled to get an evaluation of mixture formation and of its repetitiveness at spark advance. At last, spark visualization, flame visualization and combustion analysis data have been acquired in the same engine cycles to study the possible correlations between events. PIV underlined not only differences in terms of Tumble ratio, but also strong differences between airflow structures and their cycle to cycle stability. FARLIEF showed a better homogeneity of mixture formation at spark advance

  13. Combustion behaviors of GO2/GH2 swirl-coaxial injector using non-intrusive optical diagnostics

    Science.gov (United States)

    GuoBiao, Cai; Jian, Dai; Yang, Zhang; NanJia, Yu

    2016-06-01

    This research evaluates the combustion behaviors of a single-element, swirl-coaxial injector in an atmospheric combustion chamber with gaseous oxygen and gaseous hydrogen (GO2/GH2) as the propellants. A brief simulated flow field schematic comparison between a shear-coaxial injector and the swirl-coaxial injector reveals the distribution characteristics of the temperature field and streamline patterns. Advanced optical diagnostics, i.e., OH planar laser-induced fluorescence and high-speed imaging, are simultaneously employed to determine the OH radical spatial distribution and flame fluctuations, respectively. The present study focuses on the flame structures under varying O/F mixing ratios and center oxygen swirl intensities. The combined use of several image-processing methods aimed at OH instantaneous images, including time-averaged, root-mean-square, and gradient transformation, provides detailed information regarding the distribution of the flow field. The results indicate that the shear layers anchored on the oxygen injector lip are the main zones of chemical heat release and that the O/F mixing ratio significantly affects the flame shape. Furthermore, with high-speed imaging, an intuitionistic ignition process and several consecutive steady-state images reveal that lean conditions make it easy to drive the combustion instabilities and that the center swirl intensity has a moderate influence on the flame oscillation strength. The results of this study provide a visualized analysis for future optimal swirl-coaxial injector designs.

  14. Proposed experiment to investigate use of heated optical fibers for tokamak diagnostics during D-T discharges

    International Nuclear Information System (INIS)

    Tighe, W.; Morgan, P.; Griscom, D.; Adler, H.; Cylinder, D.; Johnson, D.; Palladino, D.; Ramsey, A.

    1995-02-01

    A collaborative JET/TFTR study has been undertaken to investigate attenuation and luminescence effects due to neutron irradiation of optical fibers heated to 400 degrees C. It is expected that a significant improvement in fiber behavior will be observed due to thermal annealing. This technique may be important for use in fiber-related, tokamak diagnostics exposed to high neutron flux. The study will make use of aluminum jacketed, 600 μm diameter, all silica (F-doped cladding) fibers in lengths of 150 m. The fibers are prepared in 1 foot coils. Of the coils to be irradiated, one is heated constantly to 400 degrees C, a second is not heated, and a third is heated periodically. A fourth fiber coil is not to be irradiated. Spectrally and temporally resolved transmission and luminescence data under neutron irradiation during D-T discharges on TFTR will be obtained. An investigation of permanent and short term effects will be made. Experimental details along with initial results will be presented

  15. Color-Coded Batteries - Electro-Photonic Inverse Opal Materials for Enhanced Electrochemical Energy Storage and Optically Encoded Diagnostics.

    Science.gov (United States)

    O'Dwyer, Colm

    2016-07-01

    For consumer electronic devices, long-life, stable, and reasonably fast charging Li-ion batteries with good stable capacities are a necessity. For exciting and important advances in the materials that drive innovations in electrochemical energy storage (EES), modular thin-film solar cells, and wearable, flexible technology of the future, real-time analysis and indication of battery performance and health is crucial. Here, developments in color-coded assessment of battery material performance and diagnostics are described, and a vision for using electro-photonic inverse opal materials and all-optical probes to assess, characterize, and monitor the processes non-destructively in real time are outlined. By structuring any cathode or anode material in the form of a photonic crystal or as a 3D macroporous inverse opal, color-coded "chameleon" battery-strip electrodes may provide an amenable way to distinguish the type of process, the voltage, material and chemical phase changes, remaining capacity, cycle health, and state of charge or discharge of either existing or new materials in Li-ion or emerging alternative battery types, simply by monitoring its color change. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Terbium to Quantum Dot FRET Bioconjugates for Clinical Diagnostics: Influence of Human Plasma on Optical and Assembly Properties

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2011-10-01

    Full Text Available Förster resonance energy transfer (FRET from luminescent terbium complexes (LTC as donors to semiconductor quantum dots (QDs as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma.

  17. Evaluation of the photocathode laser transverse distribution

    Energy Technology Data Exchange (ETDEWEB)

    Saisa-ard, Chaipattana [DESY, Zeuthen (Germany); Chiang Mai Univ., Chiang Mai (Thailand); Krasilnikov, Mikhail; Vashchenko, Grygorii [DESY, Zeuthen (Germany)

    2016-07-01

    Many years experience of electron source developments at the photo injector test facility at DESY in Zeuthen (PITZ) show that the photocathode laser is the one of major tools to produce high brightness electron beams. The transverse distribution of the laser on the photocathode plays a significant role in the high brightness photo injector optimization. However, the imperfections in the laser beam profile according to the deviation from a radially homogeneous profile directly result in transversely distorted charged particle distributions. This includes inhomogeneous core as well as transverse halo which is due to not sharp edges around the core. The laser transverse distribution is measured at PITZ using a virtual cathode:this is a CCD camera located at the position which is optically equivalent to the photocathode position (so called virtual cathode). An algorithm is developed for the evaluation of the experimentally obtained transverse profiles. It fits a flat-top or an inhomogeneous rotational symmetric core with exponentially decaying tails to an experimental distribution. The MATLAB script with implemented algorithm is applied to a set of measured transverse laser distributions. Results of the analysis will be presented.

  18. Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

    International Nuclear Information System (INIS)

    Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly

    2004-01-01

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system

  19. Investigation of the potential of optical coherence tomography (OCT) as a non-invasive diagnostic tool in reproductive medicine

    Science.gov (United States)

    Trottmann, Matthias; Homann, Christian; Leeb, R.; Doering, D.; Kuznetsova, J.; Reese, S.; Stief, C. G.; Koelle, S.; Sroka, R.

    2015-02-01

    Introduction and objective: In Europe, nearly every sixth couple in the reproductive age is involuntarily childless. In about 30%, both male and female reveal fertility problems. In about 10% of infertile men, azoospermia is the underlying cause. As conventional therapeutic options are limited, surgical testicular sperm extraction (TESE) is necessary to obtain sperms for assisted reproductive techniques. Regarding the females, up to 30% of all idiopathic infertilities are due to alterations of the uterine tube So far, no imaging technique, which does not require any labelling, is available to evaluate the male and female genital tract at a microscopic level under in vivo conditions. Thus, the aim of this study was to investigate the potential of optical coherence tomography (OCT) as a non-invasive diagnostic tool in gynaecology and andrology. Material and Methods: Tissues samples from the bovine testis, epididymis, vas deferens, ovary, oviduct (ampulla and isthmus) and uterus were obtained immediately after slaughter (14 cows aged 3 to 8 years and 14 bulls aged 3 to 6 years; breeds: Holstein- Friesian, and Deutsches Fleckvieh). Imaging was done by using the US Food and Drug Administration (FDA) approved probe-based Niris Imaging System (Imalux, Cleveland, Ohio, USA) and the Telesto 1325 nm OCT System and Ganymede 930 nm OCT System (Thorlabs Inc., Dachau, Germany). All images obtained were compared to histological images after paraffin embedding and HE staining. Results: OCT imaging visualized the microarchitecture of the testis, epididymis, spermatic duct and the ovary, oviduct and uterus. Using the Thorlabs systems a axial resolution of approx. 5μm and lateral resolution of 8- 15μm could be achieved. Different optical tissue volumes could be visualized, which depends on the optical penetration depth of the wavelength of the system used. While the tissue volume observed by probe based Imalux-OCT is similar to the used Thorlabs systems, the optical resolution is

  20. ASSESSMENT OF THE SKIN AND RETINAL MICROVASCULATURE WITH THE OPTICAL METHODS OF DIAGNOSTICS IN PATIENTS WITH DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    K. E. Kotliar

    2016-01-01

    Full Text Available Background: Abnormalities of microvasculature could be an early marker of diabetic complications. Therefore, its non-invasive assessment in diabetic patient seems highly relevant. Aim: To assess microcirculation in the skin and retina of patients with diabetes mellitus using optical diagnostic techniques: laser Doppler flowmetry (LDF and Retinal Vessel Analyser (RVA. Materials and methods: Cutaneous microcirculation rhythms were analyzed in 18 patients with type 2 diabetes mellitus and 16 healthy volunteers in the MONIKI (Moscow, Russia. Microcirculation in the dorsal hand and foot skin was assessed by LDF for 2 minutes. The amplitude and frequencies of perfusion oscillations corresponding to the rhythms of various etiologies were computed by Waveletanalysis. Retinal vasomotions and their changes were studied in 33 type 1 diabetic patients compared to 33 healthy volunteers in the Aachen University of Applied Sciences (Germany. Original recordings made by the RVA were used for the analysis with a  Fourier transformation, cross-correlation and autocorrelation. Results: There was no significant difference in the hand skin microcirculation rhythms assessed by LDF between patients with diabetes mellitus and healthy volunteers, whereas in the lower extremities, statistically significant differences were found in the amplitude of high-frequency oscillations corresponding to the range of the heart rhythm. These results correlate well with the results of the optical assessment of retinal vasculature, where statistically significant differences in the amplitude of high frequency oscillations corresponding to the heart rate were found. In type 1 diabetic patients the periodicity of venous pulsation was higher than in the control healthy group. Conclusion: Both dynamic analysis of the pulsations and vasomotions of retinal vessels assessed by RVA and analysis of the rhythms of blood circulation in the skin of the lower extremities measured by LDF revealed

  1. Clinical application of optical coherence tomography in combination with functional diagnostics: advantages and limitations for diagnosis and assessment of therapy outcome in central serous chorioretinopathy.

    Science.gov (United States)

    Schliesser, Joshua A; Gallimore, Gary; Kunjukunju, Nancy; Sabates, Nelson R; Koulen, Peter; Sabates, Felix N

    2014-01-01

    While identifying functional and structural parameters of the retina in central serous chorioretinopathy (CSCR) patients, this study investigated how an optical coherence tomography (OCT)-based diagnosis can be significantly supplemented with functional diagnostic tools and to what degree the determination of disease severity and therapy outcome can benefit from diagnostics complementary to OCT. CSCR patients were evaluated prospectively with microperimetry (MP) and spectral domain optical coherence tomography (SD-OCT) to determine retinal sensitivity function and retinal thickness as outcome measures along with measures of visual acuity (VA). Patients received clinical care that involved focal laser photocoagulation or pharmacotherapy targeting inflammation and neovascularization. Correlation of clinical parameters with a focus on functional parameters, VA, and mean retinal sensitivity, as well as on the structural parameter mean retinal thickness, showed that functional measures were similar in diagnostic power. A moderate correlation was found between OCT data and the standard functional assessment of VA; however, a strong correlation between OCT and MP data showed that diagnostic measures cannot always be used interchangeably, but that complementary use is of higher clinical value. The study indicates that integrating SD-OCT with MP provides a more complete diagnosis with high clinical relevance for complex, difficult to quantify diseases such as CSCR.

  2. APPLICATION OF THE SPECTRUM ANALYSIS WITH USING BERG METHOD TO DEVELOPED SPECIAL SOFTWARE TOOLS FOR OPTICAL VIBRATION DIAGNOSTICS SYSTEM

    Directory of Open Access Journals (Sweden)

    E. O. Zaitsev

    2016-01-01

    Full Text Available The objective of this paper is development and experimental verification special software of spectral analysis. Spectral analysis use of controlled vibrations objects. Spectral analysis of vibration based on use maximum-entropy autoregressive method of spectral analysis by the Berg algorithm. For measured signals use preliminary analysis based on regression analysis. This analysis of the signal enables to eliminate uninformative parameters such as – the noise and the trend. For preliminary analysis developed special software tools. Non-contact measurement of mechanical vibrations parameters rotating diffusely-reflecting surfaces used in circumstances where the use of contact sensors difficult or impossible for a number of reasons, including lack of access to the object, the small size of the controlled area controlled portion has a high temperature or is affected by strong electromagnetic fields. For control use offered laser measuring system. This measuring system overcomes the shortcomings interference or Doppler optical measuring systems. Such as measure the large amplitude and inharmonious vibration. On the basis of the proposed methods developed special software tools for use measuring laser system. LabVIEW using for developed special software. Experimental research of the proposed method of vibration signals processing is checked in the analysis of the diagnostic information obtained by measuring the vibration system grinding diamond wheel cold solid tungsten-containing alloy TK8. A result of work special software tools was complex spectrum obtained «purified» from non-informative parameters. Spectrum of the signal corresponding to the vibration process observed object. 

  3. Transverse spin physics

    CERN Document Server

    Barone, Vicenzo

    2001-01-01

    This book is devoted to the theory and phenomenology of transverse-spin effects in high-energy hadronic physics. Contrary to common past belief, it is now rather clear that such effects are far from irrelevant. A decade or so of intense theoretical work has shed much light on the subject and brought to surface an entire class of new phenomena, which now await thorough experimental investigation. Over the next few years a number of experiments world-wide (at BNL, CERN, DESY and JLAB) will run with transversely polarised beams and targets, providing data that will enrich our knowledge of the tra

  4. Transverse betatron tune measurements

    International Nuclear Information System (INIS)

    Serio, M.

    1989-01-01

    In this paper the concept of the betatron tune and the techniques to measure it are discussed. The smooth approximation is introduced along with the terminology of betatron oscillations, phase advance and tune. Single particle and beam spectra in the presence of synchro-betatron oscillations are treated with emphasis on the consequences of sampling the beam position. After a general presentation of various kinds of beam position monitors and transverse kickers, the time domain and frequency domain analysis of the beam response to a transverse excitation are discussed and several methods and applications of the tune measurements are listed

  5. Optical plasma diagnostics

    International Nuclear Information System (INIS)

    Gross, B.

    1973-01-01

    The measurement is described of the radial courses of temperature and electron, atom and ion density in the plasma of a water-stabilized arc with currents from 20 A to 60 A. For temperature measurement a method based on the determination of the relative intensity of Balmer lines was used. The electron density was measured by determining the Hsub(β) line profile and the relative density of other particles was measured by determining the intensity ratio of radiation emitted by the respective atoms or ions. (author)

  6. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  7. Transversally extended string

    International Nuclear Information System (INIS)

    Akama, Keiichi

    1988-01-01

    Starting with the space-time action of the transversally extended string, we derive its world-sheet action, which is that of a gravitational and gauge theory with matter fields on the world-sheet, with additional effects of the second fundamental quantity. (author)

  8. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  9. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  10. Transverse Spin Physics: Recent Developments

    International Nuclear Information System (INIS)

    Yuan, Feng

    2008-01-01

    Transverse-spin physics has been very active and rapidly developing in the last few years. In this talk, I will briefly summarize recent theoretical developments, focusing on the associated QCD dynamics in transverse spin physics

  11. Large transverse momentum phenomena

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1977-09-01

    It is pointed out that it is particularly significant that the quantum numbers of the leading particles are strongly correlated with the quantum numbers of the incident hadrons indicating that the valence quarks themselves are transferred to large p/sub t/. The crucial question is how they get there. Various hadron reactions are discussed covering the structure of exclusive reactions, inclusive reactions, normalization of inclusive cross sections, charge correlations, and jet production at large transverse momentum. 46 references

  12. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  13. Measurement of Sub-Picosecond Electron Bunches via Electro-Optic Sampling of Coherent Transition Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Timothy John [Northern Illinois U.

    2012-01-01

    Future collider applications as well as present high-gradient laser plasma wakefield accelerators and free-electron lasers operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. We present results on the single-shot electro-optic spectral decoding of coherent transition radiation from bunches generated at the Fermilab A0 photoinjector laboratory. A longitudinal double-pulse modulation of the electron beam is also realized by transverse beam masking followed by a transverse-to-longitudinal phase-space exchange beamline. Live profile tuning is demonstrated by upstream beam focusing in conjunction with downstream monitoring of single-shot electro-optic spectral decoding of the coherent transition radiation.

  14. Model supported sensor information platform for the transversal dynamics and longitudinal dynamics of vehicles. Applications to error diagnostics and error tolerance; Modellgestuetzte Sensorinformationsplattform fuer die Quer- und Laengsdynamik von Kraftfahrzeugen. Anwendungen zur Fehlerdiagnose und Fehlertoleranz

    Energy Technology Data Exchange (ETDEWEB)

    Halbe, Iris

    2008-07-01

    The contribution under consideration contacts engineers and scientists within the range of the motor vehicle dynamics. For the monitoring of the signals measured in series vehicle, a sensor information platform is designed. Thus, this supplies correct sensor information to the monitoring systems and offers estimated parameters and conditions for the regulation. The basis is a comprehensive concept of the transverse dynamics, longitudinal dynamics and staggering dynamics with different physical and experimental models. On the basis of these models, several procedures of error recognition are pointed out (observer, parity equations, parameter estimation), and their suitability in the driving dynamics is examined. Based on the results of error recognition, the defective sensor is diagnosed with Fuzzy in order to replace it with a computed signal. This error tolerance becomes possible by a two-trace model with a Kalman filter. Furthermore, conditions and parameters are estimated with different methods.

  15. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  16. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  17. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Mario L.R.; Goncalves, Allan C.P.; Silva, Carla T.M.; Moura, Janete P.; Ribeiro, Carolina S.; Gebrim, Eloisa M.M.S. [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Division of Ophthalmology; Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Dept. of Endocrinology; Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Division of Radiology]. E-mail: mlrmonteiro@terra.com.br

    2008-07-01

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values ({+-}SD) were 64.47% {+-} 6.06% and 49.44% {+-} 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p<0.001). Barrett's index sensitivity ranged from 32% to 100%, and Barrett's index specificity ranged from 24% to 100%. The best combination of sensitivity and specificity was 79%/72% for BI=60% (odds ratio: 9.2). Conclusions: Barrett's Index is a useful indicator of dysthyroid optic neuropathy and may contribute to early diagnosis and treatment. Patients with a Barrett's index >60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  18. Characterization and monitoring of transverse beam tails

    International Nuclear Information System (INIS)

    Seeman, J.T.; Decker, F.J.; Hsu, I.; Young, C.

    1991-05-01

    Low emittance electron beams accelerated to high energy in a linac experience transverse effects (wakefield, filamentation, optics) which produce non-Gaussian projected transverse beam distributions. Characterizations of the beam shapes are difficult because the shapes are asymmetric and change with betatron phase. In this note several methods to describe beam distributions are discussed including an accelerator physics model of these tails. The uses of these characterizations in monitoring the beam emittances in the SLC are described in this paper. First, two dimensional distributions from profile monitor screens are reviewed showing correlated tails. Second, a fitting technique for non-Gaussian one dimensional distributions is used to extract the core from the tail areas. Finally, a model for tail propagation in the linac is given. 3 refs., 6 figs

  19. Transverse spin and transverse momentum in scattering of plane waves

    OpenAIRE

    Saha, Sudipta; Singh, Ankit K.; Ray, Subir K.; Banerjee, Ayan; Gupta, Subhasish Dutta; Ghosh, Nirmalya

    2016-01-01

    We study the near field to the far field evolution of spin angular momentum (SAM) density and the Poynting vector of the scattered waves from spherical scatterers. The results show that at the near field, the SAM density and the Poynting vector are dominated by their transverse components. While the former (transverse SAM) is independent of the helicity of the incident circular polarization state, the latter (transverse Poynting vector) depends upon the polarization state. It is further demon...

  20. Comparison of roll-to-roll replication approaches for microfluidic and optical functions in lab-on-a-chip diagnostic devices

    Science.gov (United States)

    Brecher, Christian; Baum, Christoph; Bastuck, Thomas

    2015-03-01

    Economically advantageous microfabrication technologies for lab-on-a-chip diagnostic devices substituting commonly used glass etching or injection molding processes are one of the key enablers for the emerging market of microfluidic devices. On-site detection in fields of life sciences, point of care diagnostics and environmental analysis requires compact, disposable and highly functionalized systems. Roll-to-roll production as a high volume process has become the emerging fabrication technology for integrated, complex high technology products within recent years (e.g. fuel cells). Differently functionalized polymer films enable researchers to create a new generation of lab-on-a-chip devices by combining electronic, microfluidic and optical functions in multilayer architecture. For replication of microfluidic and optical functions via roll-to-roll production process competitive approaches are available. One of them is to imprint fluidic channels and optical structures of micro- or nanometer scale from embossing rollers into ultraviolet (UV) curable lacquers on polymer substrates. Depending on dimension, shape and quantity of those structures there are alternative manufacturing technologies for the embossing roller. Ultra-precise diamond turning, electroforming or casting polymer materials are used either for direct structuring or manufacturing of roller sleeves. Mastering methods are selected for application considering replication quality required and structure complexity. Criteria for the replication quality are surface roughness and contour accuracy. Structure complexity is evaluated by shapes producible (e.g. linear, circular) and aspect ratio. Costs for the mastering process and structure lifetime are major cost factors. The alternative replication approaches are introduced and analyzed corresponding to the criteria presented. Advantages and drawbacks of each technology are discussed and exemplary applications are presented.

  1. Sci-Fri AM: MRI and Diagnostic Imaging - 01: Estimating the Transverse Relaxation Time of Taurine Protons in Rat Brain at 9.4 T with Optimized PRESS Sequence Timings

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Marissa; Dobberthien, Brennen; Tessier, Anthony; Yahya, Atiyah [University of Alberta, University of Alberta, Cross Cancer Institute and University of Alberta, Cross Cancer Institute and University of Alberta (Canada)

    2016-08-15

    Purpose: To investigate the response of taurine (Tau) protons as a function of PRESS echo times, TE{sub 1} and TE{sub 2}, to determine two TE combinations that can be employed to estimate the T{sub 2} (transverse relaxation) value of Tau at 9.4 T. The Tau protons are involved in J-coupling interactions; therefore, the two timing combinations should result in similar signal losses due to J-coupling. Methods: Experiments were performed with a 9.4 T animal MRI scanner. Numerical calculations of the response of Tau as a function of PRESS TE{sub 1} and TE{sub 2} were calculated and two TE combinations that yield a similar area for the 3.42 ppm Tau resonance were selected as optimal. The timings were verified on a 50 mM Tau/10 mM Cr (creatine) phantom. In-vivo experiments were performed on four rats. Spectra were acquired with the timings from a voxel placed in the rat brain and Tau peak areas were fit to monoexponentially decaying functions to obtain T{sub 2} values. Results: The PRESS TE combinations selected for Tau T{sub 2} determination are (TE{sub 1}, TE{sub 2}) = (17 ms, 10 ms) and (80 ms, 70 ms); the signal yield for the two timings differs by 5 % theoretically. The average Tau T{sub 2} for the four rats was found to be 106 ms with a standard deviation of 12 ms. Conclusions: We have demonstrated that acquiring PRESS spectra with (TE{sub 1}, TE{sub 2}) = (17 ms, 10 ms) and (TE{sub 1}, TE{sub 2}) = (80 ms, 70 ms) enables T{sub 2} corrected measures of Tau to be obtained at 9.4 T.

  2. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  3. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  4. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  5. Transverse spin effects

    International Nuclear Information System (INIS)

    Ratcliffe, P.G.

    1993-01-01

    A discussion is presented of the role that transverse spin physics can play in providing information on the bound state dynamics in hadronic physics. Care is taken to distinguish between single- and double-spin measurements, each being discussed separately. In the case of single-spin effects it is stressed that as yet no satisfactory explanation has been provided within the framework if perturbative QCD which in fact generally predicts negligible effects. In order to clarify the situation experimental data at yet higher p T are necessary and semi-leptonic data could shed some light on the underlying scattering mechanisms. As regards double-spin correlations, the theoretical picture (although clouded by some ill-informed, often erroneous statements and even recent papers) is rather well understood and what is dearly missing is the experimental study of, for example, g 2 in deep-inelastic scattering. (author). 31 refs

  6. Optical Coherence Tomography-A New Diagnostic Tool to Evaluate Axonal Degeneration in Multiple Sclerosis: A Review

    Directory of Open Access Journals (Sweden)

    Nilüfer Kale

    2010-09-01

    Full Text Available Multiple sclerosis is an inflammatory demyelinating disorder of the central nervous system with a wide spectrum of clinical signs and symptoms. Multiple sclerosis lesions have a predilection for the optic nerves, periventricular white matter, brainstem, spinal cord, and cerebellum. The mechanisms responsible for multiple sclerosis are complex and heterogeneous across patients and disease stages. No specific markers exist for the definite diagnosis and prognosis of multiple sclerosis. The afferent visual pathway, which extends from the retina to the primary visual cortex including the optic nerve, is one of the most commonly affected sites in multiple sclerosis (94-99%. Pathology of affected optic nerves exhibits inflammation, demyelination, gliosis, axonal injury, and thinning of the retinal nerve fiber layer (RNFL. The RNFL is composed of unmyelinated axons, and measuring RNFL thickness is a viable method to monitor axonal loss reflecting disease progression. Optical coherence tomography is a noninvasive and reproducible tool in assessing the impact of multiple sclerosis on the thickness of the RNFL. Assessment of the afferent visual pathway using clinical, imaging and electrophysiological methods provides insights into the pathophysiology of multiple sclerosis and may also serve a prognostic role in multiple sclerosis

  7. Acute Transverse Myelitis in Children, Literature Review.

    Science.gov (United States)

    Tavasoli, Azita; Tabrizi, Aidin

    2018-01-01

    Acute transverse myelitis (ATM) is a rare inflammatory demyelinating disorder characterized by relatively acute onset of motor, sensory, and autonomic dysfunction. Children comprise 20% of total cases of ATM. In this review, we described the current literature on childhood ATM, focusing on the epidemiology, pathogenesis, clinical presentation, approach to diagnosis, differential diagnosis, treatment and outcome in the pediatric population. We searched the related articles in electronic databases such as Scopus, EMBASE, Google Scholar, and PubMed. All study designs were included and the essential key words for searching were myelitis, acute transverse myelitis, childhood transverse myelitis, and acquired demyelinating syndromes. The related data focusing on the epidemiology, pathogenesis, clinical presentation, diagnostic approach and differential diagnosis, treatment and outcome of pediatric ATM were gathered and described. ATM is a heterogeneous disorder in children with a broad spectrum of clinical presentation, etiology, and outcome. It may be the first presentation of relapsing acquired demyelinating syndromes and also must be distinguished from compressive and noninflamatory myelopathies. Correct diagnosis is crucial for treatment and prognosis.

  8. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  9. Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma.

    Science.gov (United States)

    Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos

    2011-01-01

    To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect

  10. Spray-combustion process characterization in a common rail diesel engine fuelled with butanol-diesel blends by conventional methods and optical diagnostics

    Directory of Open Access Journals (Sweden)

    Simona Silvia Merola

    2014-04-01

    Full Text Available The target of a sustainable mobility has led to investigate advanced combustion modes and fuels technologies. On the other side, the increasing global energy demand and the decreasing fossil-energy resources are enhancing the interest in the use of renewable alternative fuels for compression ignition engines with the target of near-zero emission levels. Although performance and emissions of alternative-fuel within light-duty diesel engines have been extensively investigated, results of fuel chemical composition impact on combustion by integrated optical methodologies are lacking. In order to meet this challenge, one of the main objectives of the research efforts is to characterize the combustion and species evolution. In this investigation, conventional tests and optical diagnostics were employed to enhance the comprehension of the combustion process and chemical markers in a common rail compression ignition engine powered by butanol-diesel blends. The investigation was focused on the effect of the injection strategy and blend composition on in-cylinder spray combustion and soot formation, through UV-visible digital imaging and natural emission spectroscopy. Experiments were performed in an optically accessible single cylinder high swirl compression ignition engine, equipped with a common rail multi-jets injection system. UV-visible emission spectroscopy was used to follow the evolution of the combustion process chemical markers. Spectral features of OH were identified and followed during the spray combustion process examining different pilot-main dwell timings. Soot spectral evidence in the visible wavelength range was correlated to soot engine out emissions. In this work, conventional and optical data related to diesel fuel blended with 40 % of n-butanol will be presented.

  11. Gold-Based Magneto/Optical Nanostructures: Challenges for In Vivo Applications in Cancer Diagnostics and Therapy.

    Science.gov (United States)

    Melancon, Marites; Lu, Wei; Li, Chun

    2009-06-01

    Nanoparticles with gold shell and iron core have unique optical and magnetic properties which can be utilized for simultaneous detection and treatment strategies. Several nanoparticles have been synthesized and shown to mediate a variety of potential applications in biomedicine, including cancer molecular optical and magnetic resonance imaging, controlled drug delivery, and photothermal ablation therapy. However, to be effective, these nanoparticles must be delivered efficiently into their targets. In this review, we will provide an updated summary of the gold-shelled magnetic nanoparticles that have been synthesized, methods for characterization, and their potential for cancer diagnosis and treatment. We will also discuss the biological barriers that need to be overcome for the effective delivery of these nanoparticles. The desired nanoparticle characteristics needed to evade these biological barriers were also explained. Hopefully, this review will help researchers in designing nanoparticles by carefully choosing the optimum size, shape, surface charge, and surface coating.

  12. Nonlinear optical diagnostic of semimagnetic semiconductors Pb1-xYb xX (X = S, Se, Te)

    International Nuclear Information System (INIS)

    Nouneh, K.; Kityk, I.V.; Viennois, R.; Benet, S.; Charar, S.; Plucinski, K.J.

    2007-01-01

    Nonlinear optical measurements were performed to elucidate the influence of magnetic ions on the behavior of charge carriers in magnetic semiconductors-Pb 1-x Yb x X (X = S, Se, Te at x = 1-3%). It was shown that nonlinear optical methods could be used as sensitive tools for investigations of electron-phonon anharmonicity near low-temperature semiconductor-insulator phase transitions. There exists a difference between surface and bulk-like contributions to the nonlinear optical effects. It was shown that only low-temperature Two Photon Absorption (TPA) oscillator may be related to the number of the electron-phonon anharmonic modes responsible for the observed phase transformation. The explanation of the anomalous temperature dependences is given in accordance with dipole momentum's behaviors determined by low-temperature spin-spin interactions and by electron-phonon anharmonic interactions. We have discovered that low-temperature dependence of specific heat of Pb 1-x R x Te (R = Yb, Pr with x = 3% and 1.6%, respectively) exhibits a non-magnetic order caused by large electron-phonon contributions and structural disorder effects

  13. Transverse electron resonance accelerator

    International Nuclear Information System (INIS)

    Osonka, P.L.

    1985-01-01

    Transverse (to the velocity, v-bar, of the particles to be accelerated) electron oscillations are generated in high (e.g. solid) density plasms by either an electromagnetic wave or by the field of charged particles traveling parallel to v-bar. The generating field oscillates with frequency ω = ω/sub p/, where ω/sub p/ is the plasma frequency. The plasma is confined to a sequence of microstructures with typical dimensions of d≅2πc/ω/sub p/, allowing the generating fields to penetrate. Since ω/sub p/ is now high, the time scales, T, are correspondingly reduced. The microstructures are allowed to explode after t = T, until then they are confined by ion inertia. As a result of resonance, the electric field, E, inside the microstructures can exceed the generating field E/sub L/. The generating force is proportional to E/sub L/ (as opposed to E 2 /sub L/). Phase matching of particles is possible by appropriate spacing of the microstructures or by a gas medium. The generating beam travels outside the plasma, filamentation is not a problem. The mechanism is relatively insensitive to the exact shape and position of the microstructures. This device contains features of various earlier proposed acceleration mechanisms and may be considered as the limiting case of several of those for small d, T and high E

  14. Transverse electron resonance accelerator

    International Nuclear Information System (INIS)

    Csonka, P.L.

    1985-01-01

    Transverse (to the velocity, v, of the particles to be accelerated) electron oscillations are generated in high (e.g. solid) density plasmas by either an electromagnetic wave or by the field of charged particles traveling parallel to v. The generating field oscillates with frequency ω = ω/sub p/, where ω/sub p/ is the plasma frequency. The plasma is confined to a sequence of microstructures with typical dimensions of d approx. = 2πc/ω/sub p/, allowing the generating fields to penetrate. Since ω/sub p/ is now high, the time scales, T, are correspondingly reduced. The microstructures are allowed to explode after t = T, until then they are confined by ion inertia. As a result of resonance, the electric field, E, inside the microstructures can exceed the generating field E/sub L/. The generating force is proportional to E/sub L/ (as opposed to E/sub L/ 2 ). Phase matching of particles is possible by appropriate spacing of the microstructures or by a gas medium. The generating beam travels outside the plasma, filamentation is not a problem. The mechanism is relatively insensitive to the exact shape and position of the microstructures. This device contains features of various earlier proposed acceleration mechanisms and may be considered as the limiting case of several of those for small d, T and high E

  15. Classical Weyl transverse gravity

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Ichiro [University of the Ryukyus, Department of Physics, Faculty of Science, Nishihara, Okinawa (Japan)

    2017-05-15

    We study various classical aspects of the Weyl transverse (WTDiff) gravity in a general space-time dimension. First of all, we clarify a classical equivalence among three kinds of gravitational theories, those are, the conformally invariant scalar tensor gravity, Einstein's general relativity and the WTDiff gravity via the gauge-fixing procedure. Secondly, we show that in the WTDiff gravity the cosmological constant is a mere integration constant as in unimodular gravity, but it does not receive any radiative corrections unlike the unimodular gravity. A key point in this proof is to construct a covariantly conserved energy-momentum tensor, which is achieved on the basis of this equivalence relation. Thirdly, we demonstrate that the Noether current for the Weyl transformation is identically vanishing, thereby implying that the Weyl symmetry existing in both the conformally invariant scalar tensor gravity and the WTDiff gravity is a ''fake'' symmetry. We find it possible to extend this proof to all matter fields, i.e. the Weyl-invariant scalar, vector and spinor fields. Fourthly, it is explicitly shown that in the WTDiff gravity the Schwarzschild black hole metric and a charged black hole one are classical solutions to the equations of motion only when they are expressed in the Cartesian coordinate system. Finally, we consider the Friedmann-Lemaitre-Robertson-Walker (FLRW) cosmology and provide some exact solutions. (orig.)

  16. Fast and sensitive medical diagnostic protocol based on integrating circular current lines for magnetic washing and optical detection of fluorescent magnetic nanobeads

    Directory of Open Access Journals (Sweden)

    Jaiyam Sharma

    2016-07-01

    Full Text Available Magnetic nanoparticles (MNPs are increasingly being used as ‘magnetic labels’ in medical diagnostics. Practical applications of MNPs necessitate reducing their non-specific interactions with sensor surfaces that result in noise in measurements. Here we describe the design and implementation of a sensing platform that incorporates circular shaped current lines that reduce non-specific binding by enabling the “magnetic washing” of loosely attached MNPs attached to the senor surface. Generating magnetic fields by passing electrical currents through the circular shaped current lines enabled the capture and collection of fluorescent MNPs that was more efficient and effective than straight current lines reported to-date. The use of fluorescent MNPs allows their optical detection rather than with widely used magnetoresistive sensors. As a result our approach is not affected by magnetic noise due to the flow of currents. Our design is expected to improve the speed, accuracy, and sensitivity of MNPs based medical diagnostics. Keywords: Biosensors, Magnetic beads, Fluorescent magnetic nanoparticles, Lab on chip, Point of care testing

  17. Diagnostics Challenges for FACET-II

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Christine

    2015-10-07

    FACET-II is a prospective user facility at SLAC National Accelerator Laboratory. The facility will focus on high-energy, high-brightness beams and their interaction with plasma and lasers. The accelerator is designed for high-energy-density electron beams with peak currents of approximately 50 kA (potentially 100 kA) that are focused down to below 10x10 micron transverse spot size at an energy of 10 GeV. Subsequent phases of the facility will provide positron beams above 10 kA peak current to the experiment station. Experiments will require well characterised beams; however, the high peak current of the electron beam can lead to material failure in wirescanners, optical transition radiation screens and other instruments critical for measurement or delivery. The radiation environment and space constraints also put additional pressure on diagnostic design.

  18. Combined optical emission and resonant absorption diagnostics of an Ar-O{sub 2}-Ce-reactive magnetron sputtering discharge

    Energy Technology Data Exchange (ETDEWEB)

    El Mel, A.A. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Institut des Matériaux Jean Rouxel, Université de Nantes, CNRS, 2 rue de la Houssinière B.P. 32229, Nantes Cedex 3 44322 (France); Ershov, S. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Britun, N., E-mail: nikolay.britun@umons.ac.be [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Ricard, A. [Université de Toulouse, UPS, INPT, LAPLACE (Laboratoire Plasma et Conversion d' Energie), 118 route de Narbonne, Toulouse Cedex 9 F-31062 (France); Konstantinidis, S. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface (ChIPS), Research Institute for Materials Science and Engineering, Université de Mons, Place du Parc 23, Mons B-7000 (Belgium); Materia Nova Research Center, Parc Initialis, Avenue Copernic 1, Mons B-7000 (Belgium)

    2015-01-01

    We report the results on combined optical characterization of Ar-O{sub 2}-Ce magnetron sputtering discharges by optical emission and resonant absorption spectroscopy. In this study, a DC magnetron sputtering system equipped with a movable planar magnetron source with a Ce target is used. The intensities of Ar, O, and Ce emission lines, as well as the absolute densities of Ar metastable and Ce ground state atoms are analyzed as a function of the distance from the magnetron target, applied DC power, O{sub 2} content, etc. The absolute number density of the Ar{sup m} is found to decrease exponentially as a function of the target-to-substrate distance. The rate of this decrease is dependent on the sputtering regime, which should be due to the different collisional quenching rates of Ar{sup m} by O{sub 2} molecules at different oxygen contents. Quantitatively, the absolute number density of Ar{sup m} is found to be equal to ≈ 3 × 10{sup 8} cm{sup −3} in the metallic, and ≈ 5 × 10{sup 7} cm{sup −3} in the oxidized regime of sputtering, whereas Ce ground state densities at the similar conditions are found to be few times lower. The absolute densities of species are consistent with the corresponding deposition rates, which decrease sharply during the transition from metallic to poisoned sputtering regime. - Highlights: • Optical emission and resonant absorption spectroscopy are employed to study Ar-O{sub 2}-Ce magnetron sputtering discharges. • The density of argon metastables is found to decrease exponentially when increasing the target-to-substrate distance. • The collision-quenching rates of Ar{sup m} by O{sub 2} molecules at different oxygen contents is demonstrated. • The deposition rates of cerium and cerium oxide thin films decrease sharply during the transition from the metallic to the poisoned sputtering regime.

  19. Examination of diagnostic features in multiphoton microscopy and optical coherence tomography images of ovarian tumorigenesis in a mouse model

    Science.gov (United States)

    Watson, Jennifer M.

    Ovarian cancer is a deadly disease owing to the non-specific symptoms and suspected rapid progression, leading to frequent late stage detection and poor prognosis. Medical imaging methods such as CT, MRI and ultrasound as well as serum testing for cancer markers have had extremely poor performance for early disease detection. Due to the poor performance of available screening methods, and the impracticality and ineffectiveness of taking tissue biopsies from the ovary, women at high risk for developing ovarian cancer are often advised to undergo prophylactic salpingo-oophorectomy. This surgery results in many side effects and is most often unnecessary since only a fraction of high risk women go on to develop ovarian cancer. Better understanding of the early development of ovarian cancer and characterization of morphological changes associated with early disease could lead to the development of an effective screening test for women at high risk. Optical imaging methods including optical coherence tomography (OCT) and multiphoton microscopy (MPM) are excellent tools for studying disease progression owing to the high resolution and depth sectioning capabilities. Further, these techniques are excellent for optical biopsy because they can image in situ non-destructively. In the studies described in this dissertation OCT and MPM are used to identify cellular and tissue morphological changes associated with early tumor development in a mouse model of ovarian cancer. This work is organized into three specific aims. The first aim is to use the images from the MPM phenomenon of second harmonic generation to quantitatively examine the morphological differences in collagen structure in normal mouse ovarian tissue and mouse ovarian tumors. The second aim is to examine the differences in endogenous two-photon excited fluorescence in normal mouse ovarian tissue and mouse ovarian tumors. The third and final aim is to identify changes in ovarian microstructure resulting from early

  20. Ultraviolet/Optical Emission of the Ionized Gas in AGN: Diagnostics of the Ionizing Source and Gas Properties

    Directory of Open Access Journals (Sweden)

    Anna Feltre

    2017-11-01

    Full Text Available Spectroscopic studies of active galactic nuclei (AGN are powerful means of probing the physical properties of the ionized gas within them. In particular, near future observational facilities, such as the James Webb Space Telescope (JWST, will allow detailed statistical studies of rest-frame ultraviolet and optical spectral features of the very distant AGN with unprecedented accuracy. In this proceedings, we discuss the various ways of exploiting new dedicated photoionization models of the narrow-line emitting regions (NLR of AGN for the interpretation of forthcoming revolutionary datasets.

  1. Ultraviolet/Optical Emission of the Ionized Gas in AGN: Diagnostics of the Ionizing Source and Gas Properties

    Energy Technology Data Exchange (ETDEWEB)

    Feltre, Anna [Univ Lyon, Univ Lyon1, Ens de Lyon, Centre National de la Recherche Scientifique, Centre de Recherche Astrophysique de Lyon UMR5574, Saint-Genis-Laval (France); Sorbonne Universités, UPMC-Centre National de la Recherche Scientifique, UMR7095, Institut d' Astrophysique de Paris, Paris (France); Charlot, Stephane [Sorbonne Universités, UPMC-Centre National de la Recherche Scientifique, UMR7095, Institut d' Astrophysique de Paris, Paris (France); Mignoli, Marco [INAF-Osservatorio Astronomico di Bologna, Bologna (Italy); Bongiorno, Angela [INAF-Osservatorio Astronomico di Roma, Monteporzio Catone (Italy); Calura, Francesco [INAF-Osservatorio Astronomico di Bologna, Bologna (Italy); Chevallard, Jacopo [Scientific Support Office, Directorate of Science and Robotic Exploration, European Space Research and Technology Centre (ESTEC), European Space Agency (ESA), Noordwijk (Netherlands); Curtis-Lake, Emma [Sorbonne Universités, UPMC-Centre National de la Recherche Scientifique, UMR7095, Institut d' Astrophysique de Paris, Paris (France); Gilli, Roberto [INAF-Osservatorio Astronomico di Bologna, Bologna (Italy); Plat, Adele, E-mail: anna.feltre@univ-lyon1.fr [Sorbonne Universités, UPMC-Centre National de la Recherche Scientifique, UMR7095, Institut d' Astrophysique de Paris, Paris (France)

    2017-11-02

    Spectroscopic studies of active galactic nuclei (AGN) are powerful means of probing the physical properties of the ionized gas within them. In particular, near future observational facilities, such as the James Webb Space Telescope (JWST), will allow detailed statistical studies of rest-frame ultraviolet and optical spectral features of the very distant AGN with unprecedented accuracy. In this proceedings, we discuss the various ways of exploiting new dedicated photoionization models of the narrow-line emitting regions (NLR) of AGN for the interpretation of forthcoming revolutionary datasets.

  2. Kinesthetic Transverse Wave Demonstration

    Science.gov (United States)

    Pantidos, Panagiotis; Patapis, Stamatis

    2005-09-01

    This is a variation on the String and Sticky Tape demonstration "The Wave Game," suggested by Ron Edge. A group of students stand side by side, each one holding a card chest high with both hands. The teacher cues the first student to begin raising and lowering his card. When he starts lowering his card, the next student begins to raise his. As succeeding students move their cards up and down, a wave such as that shown in the figure is produced. To facilitate the process, students' motions were synchronized with the ticks of a metronome (without such synchronization it was nearly impossible to generate a satisfactory wave). Our waves typically had a frequency of about 1 Hz and a wavelength of around 3 m. We videotaped the activity so that the students could analyze the motions. The (17-year-old) students had not received any prior instruction regarding wave motion and did not know beforehand the nature of the exercise they were about to carry out. During the activity they were asked what a transverse wave is. Most of them quickly realized, without teacher input, that while the wave propagated horizontally, the only motion of the transmitting medium (them) was vertical. They located the equilibrium points of the oscillations, the crests and troughs of the waves, and identified the wavelength. The teacher defined for them the period of the oscillations of the motion of a card to be the total time for one cycle. The students measured this time and then several asserted that it was the same as the wave period. Knowing the length of the waves and the number of waves per second, the next step can easily be to find the wave speed.

  3. Research on optical properties of dental enamel for early caries diagnostics using a He-Ne laser

    Science.gov (United States)

    Tang, Jing; Liu, Li; Li, Song-zhan

    2008-12-01

    A new and non-invasive method adapted for optical diagnosis of early caries is proposed by researching on the interaction mechanism of laser with dental tissue and relations of remitted light with optical properties of the tissue. This method is based on simultaneous analyses of the following parameters: probing radiation, backscattering and auto-fluorescence. Investigation was performed on 104 dental samples in vitro by using He-Ne laser (λ=632.8nm, 2.0+/-0.1mW) as the probing. Spectrums of all samples were obtained. Characteristic spectrums of dental caries in various stages (intact, initial, moderate and deep) were given. Using the back-reflected light to normalize the intensity of back-scattering and fluorescence, a quantitative diagnosis standard for different stages of caries is proposed. In order to verify the test, comparison research was conducted among artificial caries, morphological damaged enamel, dental calculus and intact tooth. Results show that variations in backscattering characteristic changes in bio-tissue morphological and the quantity of auto-fluorescence is correlated with concentration of anaerobic microflora in hearth of caries lesion. This method poses a high potential of diagnosing various stages of dental caries, and is more reliability to detect early caries, surface damage of health enamel and dental calculus.

  4. Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma

    Directory of Open Access Journals (Sweden)

    Cordeiro DV

    2011-09-01

    Full Text Available Daniela Valença Cordeiro1, Verônica Castro Lima1,2, Dinorah P Castro1,3, Leonardo C Castro1,3, Maria Angélica Pacheco2, Jae Min Lee2, Marcelo I Dimantas2, Tiago Santos Prata1,21Department of Ophthalmology, Federal University of São Paulo, São Paulo, 2Hospital Medicina dos Olhos, São Paulo, 3Centro Brasileiro de Especialidades Oftalmológicas, Araraquara, BrazilAim: To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC and conventional peripapillary retinal nerve fiber layer (pRNFL analyses provided by spectral domain optical coherence tomography (SD-OCT in glaucoma.Methods: Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers and pRNFL thickness measurement (3.45 mm circular scan by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm2 disc sizes were arbitrarily chosen (based on data distribution and the predicted areas under the ROC curves (AUCs and sensitivities were compared at fixed specificities for each.Results: Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872 and GCC parameters (average thickness = 0.824; P = 0.19.The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176 or average GCC thickness (0.088; P ≥ 0.56. AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm2 were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities – at

  5. Verification of optical diagnostic methods in H{sub 2}/D{sub 2} - plasmas; Verifikation von optischen Diagnostikmethoden an H{sub 2}/D{sub 2} - Plasmen

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Stephan

    2010-12-02

    For the neutral beam injection of the fusion experiment ITER negative deuterium ions have to be extracted from an ion source, accelerated to 1 MeV and subsequently neutralized. To control the plasma processes of the non-thermal hydrogen low temperature plasmas in the ion sources the knowledge of the plasma parameters like electron temperature and electron density is necessary. Among the required diagnostic methods the optical emission spectroscopy has one of the simplest setups which allows non-invasive and in situ measurements of the parameters. Within the scope of this thesis a modular diode system was developed, which allows together with systematically verified and improved optical diagnostic methods a time resolved online monitoring of the plasma parameters. The verification was carried out in stable and reproducible electron cyclotron resonance plasmas. These plasmas allows a simple comparison between the optical emission spectroscopy and various reference methods in a large parameter range of electron temperature and electron density. In order to verify the effective population densities from collisional radiative models and the deduced emission rate coefficients reference measurements were carried out using a Langmuir probe, a double probe, the Boyd-Twiddy-Method, interferometry, laser detachment, a mass spectrometer and already verified optical diagnostic methods of diagnostic gases like helium and argon. By a correction of the used collisional radiative model the determination of the electron density was significantly improved. (orig.)

  6. Higgs boson transverse momentum distribution

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I will review  the recent progress in understanding Higgs boson transverse momentum distribution focusing on effects that go beyond the point-like approximation for the Higgs-glue interaction vertex.

  7. Transverse correlations in multiphoton entanglement

    International Nuclear Information System (INIS)

    Wen Jianming; Rubin, Morton H.; Shih Yanhua

    2007-01-01

    We have analyzed the transverse correlation in multiphoton entanglement. The generalization of quantum ghost imaging is extended to the N-photon state. The Klyshko's two-photon advanced-wave picture is generalized to the N-photon case

  8. Diagnostic of capacitively coupled radio frequency plasma from electrical discharge characteristics: comparison with optical emission spectroscopy and fluid model simulation

    Science.gov (United States)

    Xiang, HE; Chong, LIU; Yachun, ZHANG; Jianping, CHEN; Yudong, CHEN; Xiaojun, ZENG; Bingyan, CHEN; Jiaxin, PANG; Yibing, WANG

    2018-02-01

    The capacitively coupled radio frequency (CCRF) plasma has been widely used in various fields. In some cases, it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the behavior in plasma. In this paper, a glass vacuum chamber and a pair of plate electrodes were designed and fabricated, using 13.56 MHz radio frequency (RF) discharge technology to ionize the working gas of Ar. This discharge was mathematically described with equivalent circuit model. The discharge voltage and current of the plasma were measured at different pressures and different powers. Based on the capacitively coupled homogeneous discharge model, the equivalent circuit and the analytical formula were established. The plasma density and temperature were calculated by using the equivalent impedance principle and energy balance equation. The experimental results show that when RF discharge power is 50-300 W and pressure is 25-250 Pa, the average electron temperature is about 1.7-2.1 eV and the average electron density is about 0.5 × 1017-3.6 × 1017 m-3. Agreement was found when the results were compared to those given by optical emission spectroscopy and COMSOL simulation.

  9. Optical methods for diagnostics and feedback control in laser-induced regeneration of spine disc and joint cartilages

    Science.gov (United States)

    Sobol, Emil; Sviridov, Alexander; Omeltchenko, Alexander; Baum, Olga; Baskov, Andrey; Borchshenko, Igor; Golubev, Vladimir; Baskov, Vladimir

    2011-03-01

    In 1999 we have introduced a new approach for treatment of spine diseases based on the mechanical effect of nondestructive laser radiation on the nucleus pulposus of the intervertebral disc. Laser reconstruction of spine discs (LRD) involves puncture of the disc and non-destructive laser irradiation of the nucleus pulposus to activate reparative processes in the disc tissues. In vivo animal study has shown that LRD allows activate the growth of hyaline type cartilage in laser affected zone. The paper considers physical processes and mechanisms of laser regeneration, presents results of investigations aimed to optimize laser settings and to develop feedback control system for laser reparation in cartilages of spine and joints. The results of laser reconstruction of intervertebral discs for 510 patients have shown substantial relief of back pain for 90% of patients. Laser technology has been experimentally tested for reparation of traumatic and degenerative diseases in joint cartilage of 20 minipigs. It is shown that laser regeneration of cartilage allows feeling large (more than 5 mm) defects which usually never repair on one's own. Optical techniques have been used to promote safety and efficacy of the laser procedures.

  10. The diagnostic use of choroidal thickness analysis and its correlation with visual field indices in glaucoma using spectral domain optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Zhongjing Lin

    Full Text Available To evaluate the quantitative characteristics of choroidal thickness in primary open-angle glaucoma (POAG, normal tension glaucoma (NTG and in normal eyes using spectral-domain optical coherence tomography (SD-OCT. To evaluate the diagnostic ability of choroidal thickness in glaucoma and to determine the correlation between choroidal thickness and visual field parameters in glaucoma.A total of 116 subjects including 40 POAG, 30 NTG and 46 healthy subjects were enrolled in this study. Choroidal thickness measurements were acquired in the macular and peripapillary regions using SD-OCT. All subjects underwent white-on-white (W/W and blue-on-yellow (B/Y visual field tests using Humphrey Field Analyzer. The receiver operating characteristic (ROC curve and the area under curve (AUC were generated to assess the discriminating power of choroidal thickness for glaucoma. Pearson's correlation coefficients were calculated to assess the structure function correlation for glaucoma patients.No significant differences were observed for macular choroidal thickness among the different groups (all P > 0.05. Regarding the peripapillary choroidal thickness (PPCT, significant differences were observed among the three groups (all P 0.05, but showed significant correlations with B/Y MD (all P < 0.05. In the early glaucomatous eyes, PPCT showed significant correlations with W/W MD and B/Y MD (all P < 0.05.In our study, peripapillary choroidal thickness measured on OCT showed a low to moderate but statistically significant diagnostic power and a significant correlation with blue-on-yellow visual field indices in glaucoma. This may indicate a potential adjunct for peripapillary choroidal thickness in glaucoma diagnosis.

  11. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  12. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  13. Optical properties of infrared FELs from the FELI Facility II

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, K.; Okuma, S.; Oshita, E. [Free Electron Laser Institute, Osaka (Japan)] [and others

    1995-12-31

    The FELI Facility II has succeeded in infrared FEL oscillation at 1.91 {mu} m using a 68-MeV, 40-A electron beam from the FELI S-band linac in February 27, 1995. The FELI Facility II is composed of a 3-m vertical type undulator ({lambda}u=3.8cm, N=78, Km a x=1.4, gap length {ge}20mm) and a 6.72-m optical cavity. It can cover the wavelength range of 1-5{mu}m. The FELs can be delivered from the optical cavity to the diagnostics room through a 40-m evacuated optical pipeline. Wavelength and cavity length dependences of optical properties such as peak power, average power, spectrum width, FEL macropulse, FEL transverse profile are reported.

  14. Transverse-structure electrostatic charged particle beam lens

    Science.gov (United States)

    Moran, M.J.

    1998-10-13

    Electrostatic particle-beam lenses using a concentric co-planar array of independently biased rings can be advantageous for some applications. Traditional electrostatic lenses often consist of axial series of biased rings, apertures, or tubes. The science of lens design has devoted much attention to finding axial arrangements that compensate for the substantial optical aberrations of the individual elements. Thus, as with multi-element lenses for light, a multi-element charged-particle lens can have optical behavior that is far superior to that of the individual elements. Transverse multiple-concentric-ring lenses achieve high performance, while also having advantages in terms of compactness and optical versatility. 7 figs.

  15. Transverse tails and higher order moments

    International Nuclear Information System (INIS)

    Spence, W.L.; Decker, F.J.; Woodley, M.D.

    1993-05-01

    The tails that may be engendered in a beam's transverse phase space distribution by, e.g., intrabunch wakefields and nonlinear magnetic fields, are all important diagnostic and object of tuning in linear colliders. Wire scanners or phosphorescent screen monitors yield one dimensional projected spatial profiles of such beams that are generically asymmetric around their centroids, and therefore require characterization by the third moment left-angle x 3 right-angle in addition to the conventional mean-square or second moment. A set of measurements spread over sufficient phase advance then allows the complete set left-angle x 3 right-angle, left-angle xx' 2 right-angle, left-angle x' 3 right-angle, and left-angle x 2 x'right-angle to be deduced -- the natural extension of the well-known ''emittance measurement'' treatment of second moments. The four third moments may be usefully decomposed into parts rotating in phase space at the β-tron frequency and at its third harmonic, each specified by a phase-advance-invariant amplitude and a phase. They provide a framework for the analysis and tuning of transverse wakefield tails

  16. Optical 3D scans for orthodontic diagnostics performed on full-arch impressions. Completeness of surface structure representation.

    Science.gov (United States)

    Vogel, Annike B; Kilic, Fatih; Schmidt, Falko; Rübel, Sebastian; Lapatki, Bernd G

    2015-11-01

    relatively large percentages of the total surface. However, the topographic examinations revealed that regions essential for orthodontic model analysis were missing. The malocclusion models were particularly affected. Thus, impression scans performed with structured-light scanners cannot replace scans of positive casts for diagnostic use in orthodontics.

  17. PEP-II Transverse Feedback Electronics Upgrade

    International Nuclear Information System (INIS)

    Weber, J.; Chin, M.; Doolittle, L.; Akre, R.

    2005-01-01

    The PEP-II B Factory at the Stanford Linear Accelerator Center (SLAC) requires an upgrade of the transverse feedback system electronics. The new electronics require 12-bit resolution and a minimum sampling rate of 238 Msps. A Field Programmable Gate Array (FPGA) is used to implement the feedback algorithm. The FPGA also contains an embedded PowerPC 405 (PPC-405) processor to run control system interface software for data retrieval, diagnostics, and system monitoring. The design of this system is based on the Xilinx(R) ML300 Development Platform, a circuit board set containing an FPGA with an embedded processor, a large memory bank, and other peripherals. This paper discusses the design of a digital feedback system based on an FPGA with an embedded processor. Discussion will include specifications, component selection, and integration with the ML300 design

  18. PEP-II Transverse Feedback Electronics Upgrade

    International Nuclear Information System (INIS)

    Weber, J.M.; Chin, M.J.; Doolittle, L.R.; Akre, R.

    2006-01-01

    The PEP-II B Factory at the Stanford Linear Accelerator Center (SLAC) requires an upgrade of the transverse feedback system electronics. The new electronics require 12-bit resolution and a minimum sampling rate of 238 Msps. A Field Programmable Gate Array (FPGA) is used to implement the feedback algorithm. The FPGA also contains an embedded PowerPC 405 (PPC-405) processor to run control system interface software for data retrieval, diagnostics, and system monitoring. The design of this system is based on the Xilinx(reg s ign) ML300 Development Platform, a circuit board set containing an FPGA with an embedded processor, a large memory bank, and other peripherals. This paper discusses the design of a digital feedback system based on an FPGA with an embedded processor. Discussion will include specifications, component selection, and integration with the ML300 design

  19. PEP-II Transverse Feedback Electronics Upgrade

    CERN Document Server

    Weber, Jonah; Chin, Michael; Doolittle, Lawrence

    2005-01-01

    The PEP-II B Factory at the Stanford Linear Accelerator Center (SLAC) requires an upgrade of the transverse feedback system electronics. The new electronics require 12-bit resolution and a minimum sampling rate of 238 Msps. A Field Programmable Gate Array (FPGA) is used to implement the feedback algorithm. The FPGA also contains an embedded PowerPC 405 (PPC-405) processor to run control system interface software for data retrieval, diagnostics, and system monitoring. The design of this system is based on the Xilinx® ML300 Development Platform, a circuit board set containing an FPGA with an embedded processor, a large memory bank, and other peripherals. This paper discusses the design of a digital feedback system based on an FPGA with an embedded processor. Discussion will include specifications, component selection, and integration with the ML300 design.

  20. Optical diagnostics of early flame development in a DISI (direct injection spark ignition) engine fueled with n-butanol and gasoline

    International Nuclear Information System (INIS)

    Merola, Simona Silvia; Tornatore, Cinzia; Irimescu, Adrian; Marchitto, Luca; Valentino, Gerardo

    2016-01-01

    Given the instability in supply and finite nature of fossil fuels, alternative renewable energy sources are continuously investigated throughout the production–distribution-use chain. Within this context, the research presented in this work is focused on using butanol as gasoline replacement in a Direct Injection Spark Ignition engine. The impact of this fuel on the combustion processes was investigated using optical diagnostics and conventional methods in a transparent single cylinder engine. Three different load settings were investigated at fixed engine speed, with combined throttling and mixture strength control. The engine was operated in homogenous charge mode, with commercial gasoline and pure n-butanol fueling. High spatial and temporal resolution visualization was applied in the first phase of the combustion process in order to follow the early flame development for the two fuels. The optical data were completed with conventional measurements of thermodynamic data and pollutants emission at the exhaust. Improved performance was obtained in throttled stoichiometric mode when using the alternative fuel, while at wide open throttle, gasoline featured higher indicated mean effective pressure at both air–fuel ratio settings. These overall findings were correlated to flame characteristics; the alcohol was found to feature more distorted flame contour compared to gasoline, especially in lean conditions. Differences were reduced during throttled stoichiometric operation, confirming that mass transfer processes, along with fuel chemistry and physical properties, exert a significant influence on local phenomena during combustion. - Highlights: • Butanol can replace gasoline without performance penalties in throttled, stoichiometric operation. • Butanol induces higher flame contour distortion than gasoline, especially in lean case. • Fuel chemical–physical properties strongly influence local phenomena during combustion. • Butanol ensured lower smoke

  1. Transversal lightlike submanifolds of indefinite sasakian manifolds

    OpenAIRE

    YILDIRIM, Cumali; Yıldırım, Cumali; Şahin, Bayram

    2014-01-01

    We study both radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds. We give examples, investigate the geometry of distributions and obtain necessary and sufficient conditions for the induced connection on these submanifolds to be metric connection. We also study totally contact umbilical radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds and obtain a classification theorem for totally contact umbilical tr...

  2. Transversal lightlike submanifolds of indefinite sasakian manifolds

    OpenAIRE

    YILDIRIM, Cumali

    2010-01-01

    We study both radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds. We give examples, investigate the geometry of distributions and obtain necessary and sufficient conditions for the induced connection on these submanifolds to be metric connection. We also study totally contact umbilical radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds and obtain a classification theorem for totally contact umbilical tr...

  3. Development of Laser-Induced Fluorescence Diagnostic for the Paul Trap Simulator Experiment

    CERN Document Server

    Chung, Moses; Efthimion, Philip; Gilson, Erik P; Majeski, Richard; Startsev, Edward

    2005-01-01

    The Paul Trap Simulator Experiment (PTSX) is a cylindrical Paul trap whose purpose is to simulate the nonlinear dynamics of intense charged particle beam propagation in alternating-gradient magnetic transport systems. For the in-situ measurement of the transverse ion density profile in the PTSX device, which is essential for the study of beam mismatch and halo particle production, a laser-induced fluorescence diagnostic system is being developed. Instead of cesium, which has been used in the initial phase of the PTSX experiment, barium has been selected as the preferred ion for the laser-induced fluorescence diagnostic. The installation of the barium ion source and the characterization of the tunable dye laser system are discussed. The design of the collection optics with an intensified CCD camera system is also discussed. Finally, initial test results using the laser-induced fluorescence diagnostic will be presented.

  4. Pseudoscalar Meson Electroproduction and Transversity

    International Nuclear Information System (INIS)

    Goldstein, G.; Liuti, S.

    2011-01-01

    Exclusive meson leptoproduction from nucleons in the deeply virtual exchanged boson limit can be described by generalized parton distributions (GPDs). Including spin dependence in the description requires 8 independent quark-parton and gluon-parton functions. The chiral even subset of 4 quark-nucleon GPDs are related to nucleon form factors and to parton distribution functions. The chiral odd set of 4 quark-nucleon GPDs are related to transversity, the tensor charge, and other quantities related to transversity. Different meson or photon production processes access different combinations of GPDs. This is analyzed in terms of t-channel exchange quantum numbers, J PC and it is shown that pseudoscalar production can isolate chiral odd GPDs. There is a sensitive dependence in various cross sections and asymmetries on the tensor charge of the nucleon and other transversity parameters. In a second section, analyticity and completeness are shown to limit the partonic interpret ation of the GPDs in the ERBL region.

  5. Operational status of the transverse multibunch feedback system at Diamond

    International Nuclear Information System (INIS)

    Uzun, I.; Abbott, M.; Heron, M.T.; Morgan, A.F.D.; Rehm, G.

    2012-01-01

    A transverse multibunch feedback (TMBF) system is in operation at Diamond Light Source to damp coupled-bunch instabilities up to 250 MHz in both the vertical and horizontal planes. It comprises an in-house designed and built analogue front end combined with a Libera Bunch-by-Bunch feedback processor and output stripline kickers. FPGA-based feedback electronics is used to implement several diagnostic features in addition to the basic feedback functionality. This paper reports on the current operational status of the TMBF system along with its characteristics. Also discussed are operational diagnostic functionalities including continuous measurement of the betatron tune and chromaticity. (authors)

  6. Statistical signal processing techniques for coherent transversal beam dynamics in synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Alhumaidi, Mouhammad

    2015-03-04

    identifying and analyzing the betatron oscillation sourced from the kick based on its mixing and temporal patterns. The accelerator magnets can generate unwanted spurious linear and non-linear fields due to fabrication errors or aging. These error fields in the magnets can excite undesired resonances leading together with the space charge tune spread to long term beam losses and reducing dynamic aperture. Therefore, the knowledge of the linear and non-linear magnets errors in circular accelerator optics is very crucial for controlling and compensating resonances and their consequent beam losses and beam quality deterioration. This is indispensable, especially for high beam intensity machines. Fortunately, the relationship between the beam offset oscillation signals recorded at the BPMs is a manifestation of the accelerator optics, and can therefore be exploited in the determination of the optics linear and non-linear components. Thus, beam transversal oscillations can be excited deliberately for purposes of diagnostics operation of particle accelerators. In this thesis, we propose a novel method for detecting and estimating the optics lattice non-linear components located in-between the locations of two BPMs by analyzing the beam offset oscillation signals of a BPMs-triple containing these two BPMs. Depending on the non-linear components in-between the locations of the BPMs-triple, the relationship between the beam offsets follows a multivariate polynomial accordingly. After calculating the covariance matrix of the polynomial terms, the Generalized Total Least Squares method is used to find the model parameters, and thus the non-linear components. A bootstrap technique is used to detect the existing polynomial model orders by means of multiple hypothesis testing, and determine confidence intervals for the model parameters.

  7. Investigation of Transverse Oscillation Method

    DEFF Research Database (Denmark)

    Udesen, Jesper; Jensen, Jørgen Arendt

    2006-01-01

    focus depth, receive apodization, pulse length, transverse wave length, number of emissions, signal to noise ratio, and type of echo canceling filter used. Using the experimental scanner RASMUS, the performance of the TO method is evaluated. An experimental flowrig is used to create laminar parabolic...... direction. Also the choice of echo canceling filter affects the performance significantly....

  8. Transverse stability of Kawahara solitons

    DEFF Research Database (Denmark)

    Karpman, V.I.

    1993-01-01

    The transverse stability of the planar solitons described by the fifth-order Korteweg-de Vries equation (Kawahara solitons) is studied. It is shown that the planar solitons are unstable with respect to bending if the coefficient at the fifth-derivative term is positive and stable if it is negative...

  9. Electrical modulation and switching of transverse acoustic phonons

    Science.gov (United States)

    Jeong, H.; Jho, Y. D.; Rhim, S. H.; Yee, K. J.; Yoon, S. Y.; Shim, J. P.; Lee, D. S.; Ju, J. W.; Baek, J. H.; Stanton, C. J.

    2016-07-01

    We report on the electrical manipulation of coherent acoustic phonon waves in GaN-based nanoscale piezoelectric heterostructures which are strained both from the pseudomorphic growth at the interfaces as well as through external electric fields. In such structures, transverse symmetry within the c plane hinders both the generation and detection of the transverse acoustic (TA) modes, and usually only longitudinal acoustic phonons are generated by ultrafast displacive screening of potential gradients. We show that even for c -GaN, the combined application of lateral and vertical electric fields can not only switch on the normally forbidden TA mode, but they can also modulate the amplitudes and frequencies of both modes. By comparing the transient differential reflectivity spectra in structures with and without an asymmetric potential distribution, the role of the electrical controllability of phonons was demonstrated as changes to the propagation velocities, the optical birefringence, the electrically polarized TA waves, and the geometrically varying optical sensitivities of phonons.

  10. Error diagnóstico en la neuropatía óptica epidémica Diagnostic error in epidemic optic neuropathy

    Directory of Open Access Journals (Sweden)

    Rosaralis Santiesteban Freixas

    2005-12-01

    Full Text Available La forma óptica de la epidemia de neuropatía, aparecida en el decenio pasado en Cuba, ha sido motivo de discusión por el posible hiperdiagnóstico, de los más de 22 000 casos notificados. El propósito principal de este trabajo es profundizar en la caracterización de esta enfermedad y dar a conocer la congruencia que debe de existir entre la agudeza visual y la visión de colores en las neuropatías de este tipo; además, estimar sobre la base de este elemento la posible cifra de errores diagnósticos de dos grupos de pacientes con neuropatía optica epidérmica y en un tercer grupo de pacientes que no mejoraron con tratamiento, donde se reunieron 78 casos remitidos porque no mejoraban con tratamiento vitamínico. Los resultados demostraron congruencia entre el estado de afectación de la agudeza visual y la visión de colores en más del 90 % de los 960 casos de los grupos 1 y 2, con diagnóstico de neuropatía óptica epidémica comprobados por expertos, a diferencia de los casos del tercer grupo, en los que se detectó que el 96,1 % tuvieron de inicio falsos diagnósticos de esta enfermedad p The optic form of the neuropathy epidemic that appeared in the last decade in Cuba has been discussed due to the possible hyperdiagnosis of the more than 22 000 notified cases. The main objective of this paper was to go deep into the characterization of this disease, to make known the congruency that should exist between the visual acuity and the vision of colors in the neuropathies of this type, and to estimate, on the basis of this element, the possible figure of diagnostic errors in 2 groups of patients with EON and of a third group of patients that did not improve with the treatment. In this group, there were 78 cases that were referred because they did not respond to vitamin therapy. The results showed congruency between the state of affection of visual acuity and the vision of colors in more than 90 % of the 960 cases from groups 1 and 2 with

  11. Phase control effects in optical diffraction radiation from a slit

    International Nuclear Information System (INIS)

    Castellano, M.; Chiadroni, E.; Cianchi, A.

    2010-01-01

    Optical Diffraction Radiation (ODR) from a slit is becoming a real promising instrument for measuring the transverse beam size, or even the emittance of the very high brightness linacs driving SASE FELs or the future ILC which require non-intercepting diagnostic devices. But to correctly explain experimental data it is necessary to further develop the theory of this radiation emission. In this paper we discuss in particular the effects of a non-perfect coplanarity of the two halves of a slit, that introduces a phase difference in the field produced by the two half-planes. Such non-coplanarity can result from mechanical stress for instance.

  12. A Novel Kind of Transverse Micro-Stack High-Power Diode Bars

    International Nuclear Information System (INIS)

    Lei, Zhang; Bi-Feng, Cui; Jian-Jun, Li; Wei-Lling, Guo; Zhi-Qun, Wang; Guang-Di, Shen

    2008-01-01

    Novel transverse micro-stack semiconductor laser bars are put forward to improve the output optical power of semiconductor laser bars at low injection current. More importantly, the novel laser bars have a coupled large optical cavity, which can overcome the problem of catastrophic optical damage and improve light beam quality due to the coherently coupled emitting along the transverse direction. The micro-stack tunnel regeneration tri-active region laser structure was grown by metal organic chemical vapour deposition. For a weakly coupled uncoated device, the optical power exceeds 60W under 50A driving current and the slope efficiency reaches 1.55W/A. Further experiments show that the perpendicular divergence of 23° is achieved from transverse strongly coupled devices

  13. Transverse magnetic field impact on waveguide modes of photonic crystals.

    Science.gov (United States)

    Sylgacheva, Daria; Khokhlov, Nikolai; Kalish, Andrey; Dagesyan, Sarkis; Prokopov, Anatoly; Shaposhnikov, Alexandr; Berzhansky, Vladimir; Nur-E-Alam, Mohammad; Vasiliev, Mikhail; Alameh, Kamal; Belotelov, Vladimir

    2016-08-15

    This Letter presents a theoretical and experimental study of waveguide modes of one-dimensional magneto-photonic crystals magnetized in the in-plane direction. It is shown that the propagation constants of the TM waveguide modes are sensitive to the transverse magnetization and the spectrum of the transverse magneto-optical Kerr effect has resonant features at mode excitation frequencies. Two types of structures are considered: a non-magnetic photonic crystal with an additional magnetic layer on top and a magneto-photonic crystal with a magnetic layer within each period. We found that the magneto-optical non-reciprocity effect is greater in the first case: it has a magnitude of δ∼10-4, while the second structure type demonstrates δ∼10-5 only, due to the higher asymmetry of the claddings of the magnetic layer. Experimental observations show resonant features in the optical and magneto-optical Kerr effect spectra. The measured dispersion properties are in good agreement with the theoretical predictions. An amplitude of light intensity modulation of up to 2.5% was observed for waveguide mode excitation within the magnetic top layer of the non-magnetic photonic crystal structure. The presented theoretical approach may be utilized for the design of magneto-optical sensors and modulators requiring pre-determined spectral features.

  14. Introduction to Transverse Beam Dynamics

    CERN Document Server

    Holzer, B.J.

    2014-01-01

    In this chapter we give an introduction to the transverse dynamics of the particles in a synchrotron or storage ring. The emphasis is more on qualitative understanding rather than on mathematical correctness, and a number of simulations are used to demonstrate the physical behaviour of the particles. Starting from the basic principles of how to design the geometry of the ring, we review the transverse motion of the particles, motivate the equation of motion, and show the solutions for typical storage ring elements. Following the usual treatment in the literature, we present a second way to describe the particle beam, using the concept of the emittance of the particle ensemble and the beta function, which reflects the overall focusing properties of the ring. The adiabatic shrinking due to Liouville's theorem is discussed as well as dispersive effects in the most simple case.

  15. Introduction to Transverse Beam Dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Holzer, B J [European Organization for Nuclear Research, Geneva (Switzerland)

    2014-07-01

    In this chapter we give an introduction to the transverse dynamics of the particles in a synchrotron or storage ring. The emphasis is more on qualitative understanding rather than on mathematical correctness, and a number of simulations are used to demonstrate the physical behaviour of the particles. Starting from the basic principles of how to design the geometry of the ring, we review the transverse motion of the particles, motivate the equation of motion, and show the solutions for typical storage ring elements. Following the usual treatment in the literature, we present a second way to describe the particle beam, using the concept of the emittance of the particle ensemble and the beta function, which reflects the overall focusing properties of the ring. The adiabatic shrinking due to Liouville's theorem is discussed as well as dispersive effects in the most simple case.

  16. Transversal Lines of the Debates

    Directory of Open Access Journals (Sweden)

    Yolanda Onghena

    1998-12-01

    Full Text Available The Transversal Lines of the Debates gathers for publication the presentations of the scholars invited to the seminar. In the papers, Yolanda Onghena observes that the evolution from the cultural to the inter-cultural travels along four axes: the relations between cultureand society; the processes of change within identity-based dynamics; the representations of the Other; and, interculturality. Throughout the presentations and subsequent debates, whenever the different participants referred to aspects of the cultural identity problematic--”angst”, “obsession”, “deficit”, manipulation”, and others, these same participants in the Transversal Lines of the Debates also showed that, in certain areas, an optimistic viewpoint is not out of the question.

  17. Transverse jets and their control

    Energy Technology Data Exchange (ETDEWEB)

    Karagozian, Ann R. [Department of Mechanical and Aerospace Engineering, University of California, 48-121 Engineering IV, Los Angeles, CA 90095 (United States)

    2010-10-15

    The jet in crossflow or transverse jet has been studied extensively because of its relevance to a wide variety of flows in technological systems, including fuel or dilution air injection in gas turbine engines, thrust vector control for high speed airbreathing and rocket vehicles, and exhaust plumes from power plants. These widespread applications have led over the past 50+ years to experimental, theoretical, and numerical examinations of this fundamental flowfield, with and without a combustion reaction, and with single or multi-phase flow. The complexities in this flowfield, whether the jet is introduced flush with respect to the injection wall or from an elevated pipe or nozzle, present challenges in accurately interrogating, analyzing, and simulating important jet features. This review article provides a background on these studies and applications as well as detailed features of the transverse jet, and mechanisms for its control via active means. Promising future directions for the understanding, interrogation, simulation, and control of transverse jet flows are also identified and discussed. (author)

  18. Transverse dispersion in heterogeneous fractures

    International Nuclear Information System (INIS)

    Dershowitz, Bill; Shuttle, Dawn; Klise, Kate; Outters, Nils; Hermanson, Jan

    2004-12-01

    This report evaluates the significance of transverse dispersion processes for solute transport in a single fracture. Transverse dispersion is a potentially significant process because it increases the fracture surface area available for sorptive and diffusive properties, and has the potential to transport solute between what would otherwise be distinctive, streamline pathways. Transverse dispersion processes are generally ignored in one-dimensional repository performance assessment approaches. This report provides an initial assessment of the magnitude of transverse dispersion effect in a single heterogeneous fracture on repository safety assessment. This study builds on a previous report which considered the network effects on transport dispersion including streamline routing and mixing at fracture intersections. The project uses FracMan software. This platform has been extensively used by SKB in other projects. FracMan software is designed to generate and analyze DFN's as well as to compute fluid flow in DFN's with the MAFIC Finite element method (FEM) code. Solute transport was modeled using the particle tracking inside MAFIC, the 2-D Laplace Transform Galerkin inside PAWorks/LTG, and the 1-D Laplace Transform approach designed to replicate FARF31 inside GoldSim.The study reported here focuses on a single, 20-meter scale discrete fracture, with simplified boundary conditions intended to represent the position of this fracture within a fracture network. The range of assumptions made regarding fracture heterogeneity were as follows: Base case, Heterogeneous fracture, geostatistical field, correlation length 0.01 m. Case 1a, Homogeneous fracture, transmissivity = 10 -7 m 2 /s. Case 1b, Heterogeneous fracture, non-channeled geostatistical field correlation length 5 m. Case 1c, Heterogeneous fracture, channeled, anisotropic geostatistical field. Case 1d, Heterogeneous fracture, fracture intersection zone (FIZ) permeability enhanced. Case 5, Simple channelized

  19. Average Transverse Momentum Quantities Approaching the Lightfront

    OpenAIRE

    Boer, Daniel

    2015-01-01

    In this contribution to Light Cone 2014, three average transverse momentum quantities are discussed: the Sivers shift, the dijet imbalance, and the $p_T$ broadening. The definitions of these quantities involve integrals over all transverse momenta that are overly sensitive to the region of large transverse momenta, which conveys little information about the transverse momentum distributions of quarks and gluons inside hadrons. TMD factorization naturally suggests alternative definitions of su...

  20. Transverse Momentum Distributions for Heavy Quark Pairs

    OpenAIRE

    Berger, Edmond L.; Meng, Ruibin

    1993-01-01

    We study the transverse momentum distribution for a $pair$ of heavy quarks produced in hadron-hadron interactions. Predictions for the large transverse momentum region are based on exact order $\\alpha_s^3$ QCD perturbation theory. For the small transverse momentum region, we use techniques for all orders resummation of leading logarithmic contributions associated with initial state soft gluon radiation. The combination provides the transverse momentum distribution of heavy quark pairs for all...

  1. Appraisal of transverse nasal groove: a study.

    Science.gov (United States)

    Sathyanarayana, Belagola D; Basavaraj, Halevoor B; Nischal, Kuchangi C; Swaroop, Mukunda R; Umashankar, Puttagangu N; Agrawal, Dhruv P; Swamy, Suchetha S; Okram, Sarda

    2012-01-01

    Transverse nasal groove is a condition of cosmetic concern which awaits due recognition and has been widely described as a shallow groove that extends transversely over the dorsum of nose. However, we observed variations in the clinical presentations of this entity, hitherto undescribed in literature. We conducted a clinicoepidemiological study of transverse nasal lesions in patients attending our outpatient department. We conducted a prospective observational study. We screened all patients attending our out-patient department for presence of transverse nasal lesions, signs of any dermatosis and associated other skin conditions. One hundred patients were recruited in the study. Females (80%) predominated over males. Most patients were of 15-45 years age group (70%). Majority of the transverse nasal lesions were classical transverse nasal groove (39%) and others included transverse nasal line (28%), strip (28%), ridge (4%) and loop (1%). Seborrhoeic diathesis was the most common condition associated with transverse nasal lesion. Occurrence of transverse nasal line, strip, ridge and loop, in addition to classical transverse nasal groove implies that latter is actually a subset of transverse nasal lesions. Common association of this entity with seborrheic dermatitis, seborrhea and dandruff raises a possibility of whether transverse nasal lesion is a manifestation of seborrheic diathesis.

  2. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  3. Transverse Kerr effect in one-dimensional magnetophotonic crystals: Experiment and theory

    International Nuclear Information System (INIS)

    Erokhin, S.; Boriskina, Yu.; Vinogradov, A.; Inoue, M.; Kobayashi, D.; Fedyanin, A.; Gan'shina, E.; Kochneva, M.; Granovsky, A.

    2006-01-01

    Magneto-optical transverse Kerr and Faraday effects are studied experimentally and theoretically in one-dimensional magnetophotonic crystals fabricated from a stack of four repetitions of layers of Bi-substituted yttrium iron garnet and SiO 2 layers. The results of theoretical calculations in the framework of modified matrices approach are consistent with the obtained experimental data with the exception of the one cusp at 480 nm in the transverse Kerr effect spectra. Possible mechanisms of this disagreement are discussed

  4. Entropy and transverse section reconstruction

    International Nuclear Information System (INIS)

    Gullberg, G.T.

    1976-01-01

    A new approach to the reconstruction of a transverse section using projection data from multiple views incorporates the concept of maximum entropy. The principle of maximizing information entropy embodies the assurance of minimizing bias or prejudice in the reconstruction. Using maximum entropy is a necessary condition for the reconstructed image. This entropy criterion is most appropriate for 3-D reconstruction of objects from projections where the system is underdetermined or the data are limited statistically. This is the case in nuclear medicine time limitations in patient studies do not yield sufficient projections

  5. Semiconductor laser engineering, reliability and diagnostics a practical approach to high power and single mode devices

    CERN Document Server

    Epperlein, Peter W

    2013-01-01

    This reference book provides a fully integrated novel approach to the development of high-power, single-transverse mode, edge-emitting diode lasers by addressing the complementary topics of device engineering, reliability engineering and device diagnostics in the same book, and thus closes the gap in the current book literature. Diode laser fundamentals are discussed, followed by an elaborate discussion of problem-oriented design guidelines and techniques, and by a systematic treatment of the origins of laser degradation and a thorough exploration of the engineering means to enhance the optical strength of the laser. Stability criteria of critical laser characteristics and key laser robustness factors are discussed along with clear design considerations in the context of reliability engineering approaches and models, and typical programs for reliability tests and laser product qualifications. Novel, advanced diagnostic methods are reviewed to discuss, for the first time in detail in book literature, performa...

  6. Development and Optimisation of the SPS and LHC beam diagnostics based on Synchrotron Radiation monitors

    CERN Document Server

    AUTHOR|(CDS)2081364; Roncarolo, Federico

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing t...

  7. Large transverse momentum hadronic processes

    International Nuclear Information System (INIS)

    Darriulat, P.

    1977-01-01

    The possible relations between deep inelastic leptoproduction and large transverse momentum (psub(t)) processes in hadronic collisions are usually considered in the framework of the quark-parton picture. Experiments observing the structure of the final state in proton-proton collisions producing at least one large transverse momentum particle have led to the following conclusions: a large fraction of produced particles are uneffected by the large psub(t) process. The other products are correlated to the large psub(t) particle. Depending upon the sign of scalar product they can be separated into two groups of ''towards-movers'' and ''away-movers''. The experimental evidence are reviewed favouring such a picture and the properties are discussed of each of three groups (underlying normal event, towards-movers and away-movers). Some phenomenological interpretations are presented. The exact nature of away- and towards-movers must be further investigated. Their apparent jet structure has to be confirmed. Angular correlations between leading away and towards movers are very informative. Quantum number flow, both within the set of away and towards-movers, and between it and the underlying normal event, are predicted to behave very differently in different models

  8. Transverse and Longitudinal proximity effect

    Science.gov (United States)

    Jalan, Pryianka; Chand, Hum; Srianand, Raghunathan

    2018-04-01

    With close pairs (˜1.5arcmin) of quasars (QSOs), absorption in the spectra of a background quasar in the vicinity of a foreground quasar can be used to study the environment of the latter quasar at kpc-Mpc scales. For this we used a sample of 205 quasar pairs from the Sloan Digital Sky-Survey Data Release 12 (SDSS DR12) in the redshift range of 2.5 to 3.5 by studying their H I Ly-α absorption. We study the environment of QSOs both in the longitudinal as well as in the transverse direction by carrying out a statistical comparison of the Ly-α absorption lines in the quasar vicinity to that of the absorption lines caused by the inter-galactic medium (IGM). This comparison was done with IGM, matched in absorption redshift and signal-to-noise ratio (SNR) to that of the proximity region. In contrast to the measurements along the line-of-sight, the regions transverse to the quasars exhibit enhanced H I Ly-α absorption. This discrepancy can either be interpreted as due to an anisotropic emission from the quasars or as a consequence of their finite lifetime.

  9. Laser-optical methods for earlier diagnostics of plant and seed diseases in various habitant media taking into consideration anthropogenic and biological pollution

    Science.gov (United States)

    Lisker, Joseph S.; Dmitriev, Andrey P.

    1999-12-01

    By the method of the computer laser-optical photometry the investigation of the cereal stability for the various diseases taken into consideration the stability of tomato seeds to their interaction with the phytopathogenes and the phytotoxicity of microscopic fungi on the wheat seedlings was carried out. Original result for the investigation of optical-physiological characteristics of plants and seeds are shown.

  10. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  11. Experimental investigation of transverse flow estimation using transverse oscillation

    DEFF Research Database (Denmark)

    Udesen, Jesper; Jensen, Jørgen Arendt

    2003-01-01

    Conventional ultrasound scanners can only display the blood velocity component parallel to the ultrasound beam. Introducing a laterally oscillating field gives signals from which the transverse velocity component can be estimated using 2:1 parallel receive beamformers. To yield the performance...... perpendicular to the ultrasound beam. The velocity profile of the blood is parabolic, and the speed of the blood in the center of the vessel is 1.1 m/s. An extended autocorrelation algorithm is used for velocity estimation for 310 trials, each containing 32 beamformed signals. The velocity can be estimated.......0% and the relative mean standard deviation is found to be 9.8%. With the Compuflow 1000 programmable flow pump a color flow mode image is produced of the experimental setup for a parabolic flow. Also the flow of the human femoralis is reproduced and it is found that the characteristics of the flow can be estimated....

  12. Tomography of the electron beam transverse phase space at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Asova, Galina

    2013-09-15

    The operation of a Free Elector Laser, FEL, requires high energy, high peak current electron beams with small transverse emittance. In the contemporary FELs, the electron beam is passed through a periodic magnetic structure - an undulator - which modifies the straight beam trajectory into a sinusoidal one, where FEL light is generated at each bend. According to the energy, the transverse emittance and the peak current of the beam and the parameters of the undulator, FEL radiation with wavelength in the range of nano- to micrometers can be generated. Studies and development of FELs are done all over the world. The Free electron LASer in Hamburg, FLASH, and the international European X-ray FEL, XFEL, in Hamburg, Germany, are two leading projects of the Deutsches Elektronen SYnchrotron, DESY. Part of the research program on FELs in DESY is realized in Zeuthen within the project Photo-Injector Test Facility at DESY in Zeuthen, PITZ. PITZ is an international collaboration including Germany, Russia, Italy, France, Bulgaria, Thailand, United Kingdom. The Institute of Nuclear Research and Nuclear Energy, INRNE, at the Bulgarian Academy of Sciences participates from bulgarian side. PITZ studies and optimizes the photo-injectors for FLASH and the XFEL. The research program emphasizes on detailed measurements of the transverse phase-space density distribution. Until 2010 the single slit scan technique has been used to measure the beam transverse distributions. At the end of 2010 a module for tomographic diagnostics has been installed which extends the possibilities of PITZ to measure simultaneously the two transverse planes of a single micropulse with improved signal-to-noise ratio. The difficult conditions of low emittance for high bunch charge and low energy make the operation of the module challenging. This thesis presents the design considerations for the tomography module, a number of reconstruction algorithms and their applicability to limited data sets, the influence

  13. Tomography of the electron beam transverse phase space at PITZ

    International Nuclear Information System (INIS)

    Asova, Galina

    2013-09-01

    The operation of a Free Elector Laser, FEL, requires high energy, high peak current electron beams with small transverse emittance. In the contemporary FELs, the electron beam is passed through a periodic magnetic structure - an undulator - which modifies the straight beam trajectory into a sinusoidal one, where FEL light is generated at each bend. According to the energy, the transverse emittance and the peak current of the beam and the parameters of the undulator, FEL radiation with wavelength in the range of nano- to micrometers can be generated. Studies and development of FELs are done all over the world. The Free electron LASer in Hamburg, FLASH, and the international European X-ray FEL, XFEL, in Hamburg, Germany, are two leading projects of the Deutsches Elektronen SYnchrotron, DESY. Part of the research program on FELs in DESY is realized in Zeuthen within the project Photo-Injector Test Facility at DESY in Zeuthen, PITZ. PITZ is an international collaboration including Germany, Russia, Italy, France, Bulgaria, Thailand, United Kingdom. The Institute of Nuclear Research and Nuclear Energy, INRNE, at the Bulgarian Academy of Sciences participates from bulgarian side. PITZ studies and optimizes the photo-injectors for FLASH and the XFEL. The research program emphasizes on detailed measurements of the transverse phase-space density distribution. Until 2010 the single slit scan technique has been used to measure the beam transverse distributions. At the end of 2010 a module for tomographic diagnostics has been installed which extends the possibilities of PITZ to measure simultaneously the two transverse planes of a single micropulse with improved signal-to-noise ratio. The difficult conditions of low emittance for high bunch charge and low energy make the operation of the module challenging. This thesis presents the design considerations for the tomography module, a number of reconstruction algorithms and their applicability to limited data sets, the influence

  14. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  15. Resolution enhancement of slam using transverse wave

    International Nuclear Information System (INIS)

    Ko, Dae Sik; Moon, Gun; Kim, Young H.

    1997-01-01

    We studied the resolution enhancement of a novel scanning laser acoustic microscope (SLAM) using transverse waves. Mode conversion of the ultrasonic wave takes place at the liquid-solid interface and some energy of the insonifying longitudinal waves in the water will convert to transverse wave energy within the solid specimen. The resolution of SLAM depends on the size of detecting laser spot and the wavelength of the insonifying ultrasonic waves. Since the wavelength of the transverse wave is shorter than that of the longitudinal wave, we are able to achieve the high resolution by using transverse waves. In order to operate SLAM in the transverse wave mode, we made wedge for changing the incident angle. Our experimental results with model 2140 SLAM and an aluminum specimen showed higher contrast of the SLAM Image In the transverse wave mode than that in the longitudinal wave mode.

  16. Diagnostic study of the roughness surface effect of zirconium on the third-order nonlinear-optical properties of thin films based on zinc oxide nanomaterials

    International Nuclear Information System (INIS)

    Bahedi, K.; Addou, M.; El Jouad, M.; Sofiani, Z.; Alaoui Lamrani, M.; El Habbani, T.; Fellahi, N.; Bayoud, S.; Dghoughi, L.; Sahraoui, B.; Essaidi, Z.

    2009-01-01

    Zinc oxide (ZnO) and zirconium doped zinc oxide (ZnO:Zr) thin films were deposited by reactive chemical pulverization spray pyrolysis technique on heated glass substrates at 500 deg. C using zinc and zirconium chlorides as precursors. Effects of zirconium doping agent and surface roughness on the nonlinear optical properties were investigated in detail using atomic force microscopy (AFM) and third harmonic generation (THG) technique. The best value of nonlinear optical susceptibility χ (3) was obtained from the doped films with less roughness. A strong third order nonlinear optical susceptibility χ (3) = 20.12 x 10 -12 (esu) of the studied films was found for the 3% doped sample.

  17. Deuteron transverse densities in holographic QCD

    Energy Technology Data Exchange (ETDEWEB)

    Mondal, Chandan [Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China); Indian Institute of Technology Kanpur, Department of Physics, Kanpur (India); Chakrabarti, Dipankar [Indian Institute of Technology Kanpur, Department of Physics, Kanpur (India); Zhao, Xingbo [Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China)

    2017-05-15

    We investigate the transverse charge density in the longitudinally as well as transversely polarized deuteron using the recent empirical description of the deuteron electromagnetic form factors in the framework of holographic QCD. The predictions of the holographic QCD are compared with the results of a standard phenomenological parameterization. In addition, we evaluate GPDs and the gravitational form factors for the deuteron. The longitudinal momentum densities are also investigated in the transverse plane. (orig.)

  18. Longitudinal and transverse wake potentials in SLAC

    International Nuclear Information System (INIS)

    Bane, K.; Wilson, P.

    1980-01-01

    In a machine with short bunches of high peak currents, such as the SLAC collider, one needs to know the longitudinal wake potential, for the higher mode losses, and the transverse wake potential, since, for bunches passing slightly off axis, the induced transverse forces will tend to cause beam break up. The longitudinal and transverse wakes of the SLAC structure presented here, were calculated by computer using the modal method, and including an analytic extension for higher modes. (Auth.)

  19. Laparoscopic colectomy for transverse colon carcinoma.

    Science.gov (United States)

    Zmora, O; Bar-Dayan, A; Khaikin, M; Lebeydev, A; Shabtai, M; Ayalon, A; Rosin, D

    2010-03-01

    Laparoscopic resection of transverse colon carcinoma is technically demanding and was excluded from most of the large trials of laparoscopic colectomy. The aim of this study was to assess the safety, feasibility, and outcome of laparoscopic resection of carcinoma of the transverse colon. A retrospective review was performed to identify patients who underwent laparoscopic resection of transverse colon carcinoma. These patients were compared to patients who had laparoscopic resection for right and sigmoid colon carcinoma. In addition, they were compared to a historical series of patients who underwent open resection for transverse colon cancer. A total of 22 patients underwent laparoscopic resection for transverse colon carcinoma. Sixty-eight patients operated for right colon cancer and 64 operated for sigmoid colon cancer served as comparison groups. Twenty-four patients were identified for the historical open group. Intraoperative complications occurred in 4.5% of patients with transverse colon cancer compared to 5.9% (P = 1.0) and 7.8% (P = 1.0) of patients with right and sigmoid colon cancer, respectively. The early postoperative complication rate was 45, 50 (P = 1.0), and 37.5% (P = 0.22) in the three groups, respectively. Conversion was required in 1 (5%) patient in the laparoscopic transverse colon group. The conversion rate and late complications were not significantly different in the three groups. There was no significant difference in the number of lymph nodes harvested in the laparoscopic and open groups. Operative time was significantly longer in the laparoscopic transverse colectomy group when compared to all other groups (P = 0.001, 0.008, and transverse colectomy, respectively). The results of laparoscopic colon resection for transverse colon carcinoma are comparable to the results of laparoscopic resection of right or sigmoid colon cancer and open resection of transverse colon carcinoma. These results suggest that laparoscopic resection of transverse

  20. Large transverse momentum behavior of gauge theories

    International Nuclear Information System (INIS)

    Coquereaux, Robert; De Rafael, Eduardo.

    1977-05-01

    The large transverse momentum behavior of Compton scattering and Moeller scattering in Quantum Electrodynamics; and of elastic quark-quark scattering in Quantum Chromodynamics are examined in perturbation theory. The results strongly suggest that the large transverse momentum regime in gauge theories is governed by a differential equation of the Callan-Symanzik type with a suitable momentum dependent anomalous dimension term. An explicit solution for the quark-quark elastic scattering amplitude at large transverse momentum is given

  1. Transversal light forces in semiconductors

    CERN Document Server

    Lindberg, M

    2003-01-01

    The transversal light force is a well established effect in atomic and molecular systems that are exposed to spatially inhomogeneous light fields. In this paper it is shown theoretically that in an excited semiconductor, containing an electron-hole plasma or excitons, a similar light force exists, if the semiconductor is exposed to an ultrashort spatially inhomogeneous light field. The analysis is based on the equations of motion for the Wigner distribution functions of charge carrier populations and interband polarizations. The results show that, while the light force on the electron-hole plasma or the excitons does exist, its effects on the kinetic behaviour of the electron-hole plasma or the excitons are different compared to the situation in an atomic or molecular system. A detailed analysis presented here traces this difference back to the principal differences between atoms and molecules on the one hand and electron-hole plasmas or excitons on the other hand.

  2. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  3. Transverse momentum in high-energy nuclear collisions: Collective expansion

    International Nuclear Information System (INIS)

    Wang, X.; Hwa, R.C.

    1987-01-01

    Hadron production in the central region in high-energy nuclear collisions is investigated. The hydrodynamical expansion of a locally thermalized system is studied for both the cases with and without phase transition. The case with phase transition is considered by using a sound-velocity function c/sub s/(T) parametrized to fit the energy density determined in a lattice gauge calculation. The effect of a transverse rarefaction wave is included in the calculation of the temperature profile of the expanding fluid. The transverse-momentum distribution of hadrons is calculated by collecting all the hadrons produced when the hadron gas is cooled down to a freeze-out temperature at different times in the expansion. Fluctuation in initial temperature and radius is allowed due to variation in impact parameter. On the basis of a study of the thermalization process in the parton model we impose a constraint on the initial temperature and the thermalization time, the simultaneous variation of both of which gives rise to a relationship between the average transverse momentum and rapidity density. We have found that there is no so-called ''plateau'' region in that relationship. The implication on the diagnostics of a quark-gluon plasma is discussed

  4. Comparison of diagnostic capability of macular ganglion cell complex and retinal nerve fiber layer among primary open angle glaucoma, ocular hypertension, and normal population using Fourier-domain optical coherence tomography and determining their functional correlation in Indian population

    Directory of Open Access Journals (Sweden)

    Nabanita Barua

    2016-01-01

    Full Text Available Context: Analysis of diagnostic ability of macular ganglionic cell complex and retinal nerve fiber layer (RNFL in glaucoma. Aim: To correlate functional and structural parameters and comparing predictive value of each of the structural parameters using Fourier-domain (FD optical coherence tomography (OCT among primary open angle glaucoma (POAG and ocular hypertension (OHT versus normal population. Setting and Design: Single centric, cross-sectional study done in 234 eyes. Materials and Methods: Patients were enrolled in three groups: POAG, ocular hypertensive and normal (40 patients in each group. After comprehensive ophthalmological examination, patients underwent standard automated perimetry and FD-OCT scan in optic nerve head and ganglion cell mode. The relationship was assessed by correlating ganglion cell complex (GCC parameters with mean deviation. Results were compared with RNFL parameters. Statistical Analysis: Data were analyzed with SPSS, analysis of variance, t-test, Pearson′s coefficient, and receiver operating curve. Results: All parameters showed strong correlation with visual field (P 0.5 when compared with other parameters. None of the parameters showed significant diagnostic capability to detect OHT from normal population. In diagnosing early glaucoma from OHT and normal population, only inferior GCC had statistically significant AUC value (0.715. Conclusion: In this study, GCC and RNFL parameters showed equal predictive capability in perimetric versus normal group. In early stage, inferior GCC was the best parameter. In OHT population, single day cross-sectional imaging was not valuable.

  5. The transition radiation. 2. experimental study of the optical transition radiation

    International Nuclear Information System (INIS)

    Couillaud, Ch.; Haouat, G.; Seguin, S.; Striby, S.

    1999-01-01

    Optical-transition-radiation-based diagnostics have been widely used for many years on electron accelerators in order to measure beam energy and transverse and longitudinal emittances. These diagnostics are very attractive for high brightness electron beams used as drivers for radiation sources. Such diagnostics have been performed on the ELSA facility (18 MeV electron energy, 100 A peak current) using both a single interface and an OTR-Wartski interferometer. We present the accelerator, the experimental set-up and the method for analyzing the OTR angular distribution. Then, the experimental results are described and compared with those from the three gradient method. In addition, we present a beam energy measurement using OTR interferogram analysis. (author)

  6. Transverse transport in coupled strongly correlated electronic chains

    International Nuclear Information System (INIS)

    Capponi, S.; Poilblanc, D.

    1997-01-01

    One-particle interchain hopping in a system of coupled Luttinger liquids is investigated by use of exact diagonalizations techniques. We give numerical evidence that inter-chain coherent hopping (defined by a non-vanishing splitting) can be totally suppressed for the Luttinger liquid exponent α ∝ 0.4 or even smaller α values. The transverse conductivity is shown to exhibit a strong incoherent part even when coherent inter-chain hopping is believed to occur. Implications for the optical experiments in quasi-1D organic or high-T c superconductors is outlined. (orig.)

  7. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    Science.gov (United States)

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Anaesthetic considerations in patients with transverse myelitis ...

    African Journals Online (AJOL)

    Transverse myelitis is an acute or subacute inflammatory disorder involving the spinal cord. Clinical signs are due to the involvement of the ascending and descending tracts in the transverse plane of the spinal cord. The most common cause is autoimmune. These patients may present with various clinical findings with ...

  9. Transversals in non-discrete groups

    Indian Academy of Sciences (India)

    Transversals in non-discrete groups. RAMJI LAL and R P SHUKLA. Department of Mathematics, University of Allahabad, Allahabad 211 002, India. E-mail: ramjilal@mri.ernet.in; rps@mri.ernet.in. MS received 2 August 2004; revised 4 August 2005. Abstract. The concept of 'topological right transversal' is introduced to study ...

  10. Transverse momentum distributions of identified particles produced ...

    Indian Academy of Sciences (India)

    We assume that the transverse momentum distributions of identified particles measured in final state are contributed by a few energy sources which can be regarded as partons or quarks in the interacting system. The particle is contributed by each source with gluons which have transverse momentum distributions in an ...

  11. Cladding For Transversely-Pumped Laser Rod

    Science.gov (United States)

    Byer, Robert L.; Fan, Tso Yee

    1989-01-01

    Combination of suitable dimensioning and cladding of neodymium:yttrium aluminum garnet of similar solid-state laser provides for more efficient utilization of transversely-incident pump light from diode lasers. New design overcomes some of limitations of longitudinal- and older transverse-pumping concepts and promotes operation at higher output powers in TEM00 mode.

  12. Diagnostic study of the roughness surface effect of zirconium on the third-order nonlinear-optical properties of thin films based on zinc oxide nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Bahedi, K., E-mail: bahedikhadija@yahoo.com [Laboratoire Optoelectronique et Physico-chimie des Materiaux Universite Ibn Tofail, Faculte des Sciences BP 133 Kenitra 14000, Maroc (Morocco); Addou, M.; El Jouad, M.; Sofiani, Z.; Alaoui Lamrani, M.; El Habbani, T.; Fellahi, N.; Bayoud, S.; Dghoughi, L. [Laboratoire Optoelectronique et Physico-chimie des Materiaux Universite Ibn Tofail, Faculte des Sciences BP 133 Kenitra 14000, Maroc (Morocco); Sahraoui, B.; Essaidi, Z. [Laboratoire POMA, UMR CNRS 6136, Universite d' Angers 2, Bd Lavoisier, 49045 France (France)

    2009-02-01

    Zinc oxide (ZnO) and zirconium doped zinc oxide (ZnO:Zr) thin films were deposited by reactive chemical pulverization spray pyrolysis technique on heated glass substrates at 500 deg. C using zinc and zirconium chlorides as precursors. Effects of zirconium doping agent and surface roughness on the nonlinear optical properties were investigated in detail using atomic force microscopy (AFM) and third harmonic generation (THG) technique. The best value of nonlinear optical susceptibility {chi}{sup (3)} was obtained from the doped films with less roughness. A strong third order nonlinear optical susceptibility {chi}{sup (3)} = 20.12 x 10{sup -12} (esu) of the studied films was found for the 3% doped sample.

  13. Growth of transverse coherence in SASE FELs

    International Nuclear Information System (INIS)

    Kumar, Vinit; Krishnagopal, Srinivas

    2000-01-01

    We introduce the correlation function between the electric field at two different points in the transverse plane as a parameter to quantify the degree of transverse coherence. We also propose a more realistic model for the initialization of the radiation in computer codes used to study SASE FELs. We make these modifications in the code TDA and use it to study the growth of transverse coherence as a function of electron beam size, beam current and transverse emittance. Our results show explicitly that the onset of full transverse coherence in SASE takes place much before the power saturates. With the more realistic model the onset of the exponential growth regime is delayed, and to get a given power from the FEL one needs a longer undulator than would be predicted by the original TDA code

  14. Transverse excitations of 19F

    International Nuclear Information System (INIS)

    Donne, A.J.H.

    1985-01-01

    In this thesis aspects of the structure of the nucleus 19 F are discussed as a result of transverse electron-scattering experiments, with emphasis on the ground state. The magnetization distribution of this state has been obtained from the measurement of electrons scattered from 19 F at backward angles. An introduction to the electron-scattering formalism is presented briefly together with the interpretation of electron-scattering results in terms of the nuclear shell model. The experimental apparatus for the measurement of electron scattering through an angle of 180 0 is described. This instrumentation has been installed in the low-energy facility (LEF) at NIKHEF-K. Simultaneously with the study of the magnetic ground state distribution of 19 F, also excited states of this nucleus up to an energy of 4.4 MeV have been investigated, mainly from data obtained in the EMIN station. Also for these states, the shell-model calculations have been the guide to determine their structure. (Auth.)

  15. Evaluation of the optical design of laser Thomson scattering diagnostics for high-temperature EAST tokamak and low-temperature MAP-II divertor simulator

    International Nuclear Information System (INIS)

    Kado, Shinichiro; Scotti, Filippo; Xi Xiaoqi; Zhao Junyu

    2009-01-01

    The optical design of the laser Thomson scattering (LTS) system for EAST tokamak is now on-going. Based on the Visible YAG laser TVTS system developed in the MAP-II (material and plasma) steady-state linear divertor/edge plasma simulator at the University of Tokyo, the required specification and the applicability of the VIS-YAG-TVTS system was evaluated in terms of the photon number to be collected by the fiber light-guide to a spectrometer and the reciprocal linear dispersion of the spectrometer. Then, the possible design of the optical system was proposed. (author)

  16. Transverse pumped laser amplifier architecture

    Science.gov (United States)

    Bayramian, Andrew James; Manes, Kenneth; Deri, Robert; Erlandson, Al; Caird, John; Spaeth, Mary

    2013-07-09

    An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

  17. STELLA Experiment - Microbunch Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    He, P.; Liu, Y.; Cline, D. B.; Babzien, M.; Gallardo, J. C.; Kusche, K. P.; Pogorelsky, I. V.; Skaritka, J.; van Steenbergen, A.; Yakimenko, V.; Kimura, W. D.

    1998-07-01

    A microbunch diagnostic system is built at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory for monitoring microbunches (10-fs bunch length) produced by the Inverse Free Electron Laser accelerator in Staged Electron Laser Acceleration experiment. It is similar to one already demonstrated at the ATF. With greatly improved beam optics conditions higher order harmonic coherent transition radiation will be measurable to determine the microbunch length and shape.

  18. RFQ1 diagnostic devices

    International Nuclear Information System (INIS)

    Chidley, B.G.; Arbique, G.M.; de Jong, M.S.; McMichael, G.E.; Michel, W.L.; Smith, B.H.

    1991-01-01

    The diagnostic devices in use on RFQ1 will be described. They consist of a double-slit emittance-measuring unit, a 45 degree deflection energy-analysis magnet, parametric current transformers, optical beam sensors, beam-stop current monitors, and an x-ray end-point analyzer. All of these devices are able to operate up to the full output current of RFQ1 (75 mA cw at 0.6 MeV)

  19. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  20. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  1. Devic's Disease (Neuromyelitis optical)

    International Nuclear Information System (INIS)

    Pinzon, Alfredo; Echeverry, Tatiana; Rodriguez, Aida Bibiana

    2010-01-01

    We present a case report about a young woman initially treated as having multiple sclerosis, who relapsed with serious visual impairment. Devic's disease is a demyelinating disorder that presents as transverse myelitis associated with optic neuritis, typically bilateral. Multiple sclerosis is in fact the main differential diagnosis

  2. Simulation with Python on transverse modes of the symmetric confocal resonator

    Science.gov (United States)

    Wang, Qing Hua; Qi, Jing; Ji, Yun Jing; Song, Yang; Li, Zhenhua

    2017-08-01

    Python is a popular open-source programming language that can be used to simulate various optical phenomena. We have developed a suite of programs to help teach the course of laser principle. The complicated transverse modes of the symmetric confocal resonator can be visualized in personal computers, which is significant to help the students understand the pattern distribution of laser resonator.

  3. Summary Report on Synchronization, Diagnostics and Instrumentation

    International Nuclear Information System (INIS)

    Arne Freyberger

    2005-01-01

    The proceedings of Working Group 4 of the 2005 Energy Recovery Linac (ERL) workshop are summarized. Working Group 4 dealt with the challenging topic of beam diagnostics for ERL machines. Energy Recovery Linacs represent a challenge for beam diagnostics from several perspectives; invasive versus non-invasive diagnostics, longitudinal and transverse beam diagnostics, overall machine timing/synchronization and machine protection. Beam diagnostics for an ERL can benefit strongly from the experience at third generation light sources, recirculating linacs and presently operating ERLs. During the workshop there were presentations from all these communities, representing a large range operation experience in beam diagnostics. A brief summary Working Group 4 discussion is presented in this paper

  4. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  5. Transverse Schottky spectra and beam transfer functions of coasting ion beams with space charge

    International Nuclear Information System (INIS)

    Paret, Stefan

    2010-01-01

    A study of the transverse dynamics of coasting ion beams with moderate space charge is presented in this work. From the dispersion relation with linear space charge, an analytic model describing the impact of space charge on transverse beam transfer functions (BTFs) and the stability limits of a beam is derived. The dielectric function obtained in this way is employed to describe the transverse Schottky spectra with linear space charge as well. The difference between the action of space charge and impedances is highlighted. The setup and the results of an experiment performed in the heavy ion synchrotron SIS-18 at GSI to detect space-charge effects at different beam intensities are explicated. The measured transverse Schottky spectra and BTFs are compared with the linear space-charge model. The stability diagrams constructed from the BTFs are presented. The space-charge parameters evaluated from the Schottky and BTF measurements are compared with estimations based on measured beam parameters. The impact of collective effects on the Schottky and BTF diagnostics is also investigated through numerical simulations. For this purpose the self-field of beams with linear and non-linear transverse density-distributions is computed on a twodimensional grid. The noise of the random particle distribution causes fluctuations of the dipole moment of the beam which produce the Schottky spectrum. BTFs are simulated by exciting the beam with transverse kicks. The simulation results are used to verify the space-charge model. (orig.)

  6. Transverse Schottky spectra and beam transfer functions of coasting ion beams with space charge

    Energy Technology Data Exchange (ETDEWEB)

    Paret, Stefan

    2010-02-22

    A study of the transverse dynamics of coasting ion beams with moderate space charge is presented in this work. From the dispersion relation with linear space charge, an analytic model describing the impact of space charge on transverse beam transfer functions (BTFs) and the stability limits of a beam is derived. The dielectric function obtained in this way is employed to describe the transverse Schottky spectra with linear space charge as well. The difference between the action of space charge and impedances is highlighted. The setup and the results of an experiment performed in the heavy ion synchrotron SIS-18 at GSI to detect space-charge effects at different beam intensities are explicated. The measured transverse Schottky spectra and BTFs are compared with the linear space-charge model. The stability diagrams constructed from the BTFs are presented. The space-charge parameters evaluated from the Schottky and BTF measurements are compared with estimations based on measured beam parameters. The impact of collective effects on the Schottky and BTF diagnostics is also investigated through numerical simulations. For this purpose the self-field of beams with linear and non-linear transverse density-distributions is computed on a twodimensional grid. The noise of the random particle distribution causes fluctuations of the dipole moment of the beam which produce the Schottky spectrum. BTFs are simulated by exciting the beam with transverse kicks. The simulation results are used to verify the space-charge model. (orig.)

  7. Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

    CERN Document Server

    Cantero, E D; Bravin, E; Sosa, A

    2014-01-01

    We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.

  8. Ferroelectric Cathodes in Transverse Magnetic Fields

    International Nuclear Information System (INIS)

    Alexander Dunaevsky; Yevgeny Raitses; Nathaniel J. Fisch

    2002-01-01

    Experimental investigations of a planar ferroelectric cathode in a transverse magnetic field up to 3 kGs are presented. It is shown that the transverse magnetic field affects differently the operation of ferroelectric plasma cathodes in ''bright'' and ''dark'' modes in vacuum. In the ''bright'' mode, when the surface plasma is formed, the application of the transverse magnetic field leads to an increase of the surface plasma density. In the ''dark'' mode, the magnetic field inhibits the development of electron avalanches along the surface, as it does similarly in other kinds of surface discharges in the pre-breakdown mode

  9. Scaling properties of the transverse mass spectra

    International Nuclear Information System (INIS)

    Schaffner-Bielich, J.

    2002-01-01

    Motivated from the formation of an initial state of gluon-saturated matter, we discuss scaling relations for the transverse mass spectra at BNL's relativistic heavy-ion collider (RHIC). We show on linear plots, that the transverse mass spectra for various hadrons can be described by an universal function in m t . The transverse mass spectra for different centralities can be rescaled into each other. Finally, we demonstrate that m t -scaling is also present in proton-antiproton collider data and compare it to m t -scaling at RHIC. (orig.)

  10. Advanced Optical Processing of Microwave Signals

    Directory of Open Access Journals (Sweden)

    Miguel V. Andrés

    2005-06-01

    Full Text Available The authors present a review on the recent approaches proposed to implement transversal RF filters. Different tunable transversal filters consisting of wavelength tunable optical taps and those employing the tunability of dispersive devices are presented showing their high-performance characteristics. A comprehensive review of the fundamentals and a discussion on the main limitation of these structures are also included.

  11. Clinical application of optical coherence tomography in combination with functional diagnostics: advantages and limitations for diagnosis and assessment of therapy outcome in central serous chorioretinopathy

    OpenAIRE

    Koulen, Peter; Schliesser,Joshua; Gallimore,Gary; Kunjukunju,Nancy; Sabates,Nelson; Sabates,Felix

    2014-01-01

    Joshua A Schliesser, Gary Gallimore, Nancy Kunjukunju, Nelson R Sabates, Peter Koulen, Felix N Sabates Vision Research Center, Department of Ophthalmology, University of Missouri – Kansas City, School of Medicine, Kansas City, MO, USA Purpose: While identifying functional and structural parameters of the retina in central serous chorioretinopathy (CSCR) patients, this study investigated how an optical coherence tomography (OCT)-based diagnosis can be significantly supplemented with...

  12. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  13. Notes on the design of experiments and beam diagnostics with synchrotron light detected by a gated photomultiplier for the Fermilab superconducting electron linac and for the Integrable Optics Test Accelerator (IOTA)

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Romanov, Aleksandr [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Ruan, Jinhao [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Santucci, James [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Thurman-Keup, Randy [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Valishev, Alexander [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-11-08

    We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons in bend dipoles, detected with gated microchannel-plate photomultipliers (MCP-PMTs). The system can be used both for beam diagnostics (e.g., beam intensity with full dynamic range, turn-by-turn beam vibrations, etc.) and for scientific experiments, such as the direct observation of the time structure of the radiation emitted by single electrons in a storage ring. The similarity between photon pulses and spectrum at the downstream end of the electron linac and in the IOTA ring allows one to test the apparatus during commissioning of the linac.

  14. An investigation into the role of metastable states on excited populations of weakly ionized argon plasmas, with applications for optical diagnostics

    Science.gov (United States)

    Arnold, Nicholas; Loch, Stuart; Ballance, Connor; Thomas, Ed

    2017-10-01

    Low temperature plasmas (Te ADAS) code suite to calculate a level-resolved, generalized collisional-radiative (GCR) model for line emission in low temperature argon plasmas. By combining our theoretical model with experimental electron temperature, density, and spectral measurements from the Auburn Linear eXperiment for Instability Studies (ALEXIS), we have developed diagnostic techniques to measure metastable fraction, electron temperature, and electron density. In the future we hope to refine our methods, and extend our model to plasmas other than ALEXIS. Supported by the U.S. Department of Energy. Grant Number: DE-FG02-00ER54476.

  15. A transverse lattice QCD model for mesons

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Apoorva D.; Ratabole, Raghunath

    2004-03-01

    QCD is analysed with two light-front continuum dimensions and two transverse lattice dimensions. In the limit of large number of colours and strong transverse gauge coupling, the contributions of light-front and transverse directions factorise in the dynamics, and the theory can be analytically solved in a closed form. An integral equation is obtained, describing the properties of mesons, which generalises the 't Hooft equation by including spin degrees of freedom. The meson spectrum, light-front wavefunctions and form factors can be obtained by solving this equation numerically. These results would be a good starting point to model QCD observables which only weakly depend on transverse directions, e.g. deep inelastic scattering structure functions.

  16. Constituent models and large transverse momentum reactions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1975-01-01

    The discussion of constituent models and large transverse momentum reactions includes the structure of hard scattering models, dimensional counting rules for large transverse momentum reactions, dimensional counting and exclusive processes, the deuteron form factor, applications to inclusive reactions, predictions for meson and photon beams, the charge-cubed test for the e/sup +-/p → e/sup +-/γX asymmetry, the quasi-elastic peak in inclusive hadronic reactions, correlations, and the multiplicity bump at large transverse momentum. Also covered are the partition method for bound state calculations, proofs of dimensional counting, minimal neutralization and quark--quark scattering, the development of the constituent interchange model, and the A dependence of high transverse momentum reactions

  17. Phase diagrams of diluted transverse Ising nanowire

    Energy Technology Data Exchange (ETDEWEB)

    Bouhou, S.; Essaoudi, I. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Ainane, A., E-mail: ainane@pks.mpg.de [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Saber, M. [Laboratoire de Physique des Matériaux et Modélisation, des Systèmes, (LP2MS), Unité Associée au CNRST-URAC 08, University of Moulay Ismail, Physics Department, Faculty of Sciences, B.P. 11201 Meknes (Morocco); Max-Planck-Institut für Physik Complexer Systeme, Nöthnitzer Str. 38 D-01187 Dresden (Germany); Ahuja, R. [Condensed Matter Theory Group, Department of Physics and Astronomy, Uppsala University, 75120 Uppsala (Sweden); Dujardin, F. [Laboratoire de Chimie et Physique des Milieux Complexes (LCPMC), Institut de Chimie, Physique et Matériaux (ICPM), 1 Bd. Arago, 57070 Metz (France)

    2013-06-15

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J{sub cs} exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given.

  18. Phase diagrams of diluted transverse Ising nanowire

    International Nuclear Information System (INIS)

    Bouhou, S.; Essaoudi, I.; Ainane, A.; Saber, M.; Ahuja, R.; Dujardin, F.

    2013-01-01

    In this paper, the phase diagrams of diluted Ising nanowire consisting of core and surface shell coupling by J cs exchange interaction are studied using the effective field theory with a probability distribution technique, in the presence of transverse fields in the core and in the surface shell. We find a number of characteristic phenomena. In particular, the effect of concentration c of magnetic atoms, the exchange interaction core/shell, the exchange in surface and the transverse fields in core and in surface shell of phase diagrams are investigated. - Highlights: ► We use the EFT to investigate the phase diagrams of Ising transverse nanowire. ► Ferrimagnetic and ferromagnetic cases are investigated. ► The effects of the dilution and the transverse fields in core and shell are studied. ► Behavior of the transition temperature with the exchange interaction is given

  19. Transverse momentum signatures for heavy Higgs bosons

    International Nuclear Information System (INIS)

    Cahn, R.N.; Ellis, S.D.; Kleiss, R.; Stirling, W.J.

    1986-01-01

    Heavy Higgs bosons produced by WW fusion at the SSC will have transverse mementum of order M/sub w/. The background due to q anti q → ZZ will produce pairs with characteristically less transverse momentum. This provides a useful discriminator. It may be possible to tag the WW fusion events in a manner analogous to that used in two photon physics. 12 refs., 4 figs

  20. Laparoscopic correction of right transverse colostomy prolapse.

    Science.gov (United States)

    Gundogdu, Gokhan; Topuz, Ufuk; Umutoglu, Tarik

    2013-08-01

    Colostomy prolapse is a frequently seen complication of transverse colostomy. In one child with recurrent stoma prolapse, we performed a loop-to-loop fixation and peritoneal tethering laparoscopically. No prolapse had recurred at follow-up. Laparoscopic repair of transverse colostomy prolapse seems to be a less invasive method than other techniques. © 2013 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  1. Chiral dynamics and peripheral transverse densities

    Energy Technology Data Exchange (ETDEWEB)

    Granados, Carlos G. [Uppsala University (Sweden); Weiss, Christian [JLAB, Newport News, VA (United States)

    2014-01-01

    In the partonic (or light-front) description of relativistic systems the electromagnetic form factors are expressed in terms of frame-independent charge and magnetization densities in transverse space. This formulation allows one to identify the chiral components of nucleon structure as the peripheral densities at transverse distances b = O(M{sub {pi}}{sup -1}) and compute them in a parametrically controlled manner. A dispersion relation connects the large-distance behavior of the transverse charge and magnetization densities to the spectral functions of the Dirac and Pauli form factors near the two--pion threshold at timelike t = 4 M{ sub {pi}}{sup 2}, which can be computed in relativistic chiral effective field theory. Using the leading-order approximation we (a) derive the asymptotic behavior (Yukawa tail) of the isovector transverse densities in the "chiral" region b = O(M{sub {pi}}{sup -1}) and the "molecular" region b = O(M{sub N}{sup 2}/M{sub {pi}}{sup 3}); (b) perform the heavy-baryon expansion of the transverse densities; (c) explain the relative magnitude of the peripheral charge and magnetization densities in a simple mechanical picture; (d) include Delta isobar intermediate states and study the peripheral transverse densities in the large-N{ sub c} limit of QCD; (e) quantify the region of transverse distances where the chiral components of the densities are numerically dominant; (f) calculate the chiral divergences of the b{sup 2}-weighted moments of the isovector transverse densities (charge and anomalous magnetic radii) in the limit M{sub {pi}} -> 0 and determine their spatial support. Our approach provides a concise formulation of the spatial structure of the nucleon's chiral component and offers new insights into basic properties of the chiral expansion. It relates the information extracted from low-t elastic form factors to the generalized parton distributions probed in peripheral high-energy scattering processes.

  2. Results from the AGS Booster transverse damper

    International Nuclear Information System (INIS)

    Russo, D.; Brennan, M.; Meth, M.; Roser, T.

    1993-01-01

    To reach the design intensity of 1.5 x 10 13 protons per pulse in the AGS Booster, transverse coupled bunch instabilities with an estimated growth rate of 1500s -1 have to be dampened. A prototype transverse damper has been tested successfully using a one turn digital delay and closed orbit suppression implemented in a programmable gate array. An updated damper, which includes an algorithm to optimize damping for a changing betatron rune, will also be presented

  3. Control of Supercavitating Vehicles using Transverse Jets

    Science.gov (United States)

    2016-03-15

    Supercavitating Vehicles using Transverse Jets Sb. GRANT NUMBER N00014-13-1-0747 Sc. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Sd. PROJECT NUMBER Ayers, Bradley...ANSI Std. Z39.18 CONTROL OF SUPERCAVITATING VEHICLES USING TRANSVERSE JETS Final Technical Report for Office of Naval Research contract N00014-13-1...fully-submerged, supercavitating vehicle model using the thrust of the zero-net-mass-flux device. The experiments were conducted in NUWC Newport’ s

  4. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  5. Transverse structure of the QCD string

    International Nuclear Information System (INIS)

    Meyer, Harvey B.

    2010-01-01

    The characterization of the transverse structure of the QCD string is discussed. We formulate a conjecture as to how the stress-energy tensor of the underlying gauge theory couples to the string degrees of freedom. A consequence of the conjecture is that the energy density and the longitudinal-stress operators measure the distribution of the transverse position of the string, to leading order in the string fluctuations, whereas the transverse-stress operator does not. We interpret recent numerical measurements of the transverse size of the confining string and show that the difference of the energy and longitudinal-stress operators is a particularly natural probe at next-to-leading order. Second, we derive the constraints imposed by open-closed string duality on the transverse structure of the string. We show that a total of three independent ''gravitational'' form factors characterize the transverse profile of the closed string, and obtain the interpretation of recent effective string theory calculations: the square radius of a closed string of length β defined from the slope of its gravitational form factor, is given by (d-1/2πσ)log(β/4r 0 ) in d space dimensions. This is to be compared with the well-known result that the width of the open string at midpoint grows as (d-1/2πσ)log(r/r 0 ). We also obtain predictions for transition form factors among closed-string states.

  6. A Study of Large Transverse Momentum Phenomena

    CERN Multimedia

    2002-01-01

    This experiment studies the structure of those p-p and @*-p collisions which are characterized by a very high transverse momentum flow in the central region. Some specific items studied are:\\\\ \\\\ \\item -~~Structure of events, where the high transverse momentum is shared by charged and neutral hadron (``jets''). Transverse momentum distribution, correlations and momentum balance for such events. \\item -~~Structure of events, where the high transverse momentum is mostly carried by one identified particle. Quantum number dependence and quantum number correlations of the high transverse momentum events. \\item -~~Structure of events containing large transverse momentum leptons or lepton pairs or direct photons. \\end{enumerate}.sk -~~Study of low momentum electrons and photons. -~~Search for gluonium states. -~~Search for new and rare particles. \\\\ \\\\ A conventional C-type magnet with a 0.5 T field in the direction of the beams together with a 42-layer cylindrical drift chamber detector is used for momentum analysi...

  7. Transverse angular momentum in topological photonic crystals

    Science.gov (United States)

    Deng, Wei-Min; Chen, Xiao-Dong; Zhao, Fu-Li; Dong, Jian-Wen

    2018-01-01

    Engineering local angular momentum of structured light fields in real space enables applications in many fields, in particular, the realization of unidirectional robust transport in topological photonic crystals with a non-trivial Berry vortex in momentum space. Here, we show transverse angular momentum modes in silicon topological photonic crystals when considering transverse electric polarization. Excited by a chiral external source with either transverse spin angular momentum or transverse phase vortex, robust light flow propagating along opposite directions is observed in several kinds of sharp-turn interfaces between two topologically-distinct silicon photonic crystals. A transverse orbital angular momentum mode with alternating phase vortex exists at the boundary of two such photonic crystals. In addition, unidirectional transport is robust to the working frequency even when the ring size or location of the pseudo-spin source varies in a certain range, leading to the superiority of the broadband photonic device. These findings enable one to make use of transverse angular momentum, a kind of degree of freedom, to achieve unidirectional robust transport in the telecom region and other potential applications in integrated photonic circuits, such as on-chip robust delay lines.

  8. Evaluation of idiopathic transverse myelitis revealing specific myelopathy diagnoses.

    Science.gov (United States)

    Zalewski, Nicholas L; Flanagan, Eoin P; Keegan, B Mark

    2018-01-09

    To evaluate specific myelopathy diagnoses made in patients with suspected idiopathic transverse myelitis (ITM). A total of 226 patients 18 years and older were referred to Mayo Clinic Neurology for suspected ITM from December 1, 2010, to December 31, 2015. Electronic medical records were reviewed for detailed clinical presentation and course, laboratory and electrophysiologic investigations, and neuroimaging to determine the etiology. Current diagnostic criteria for ITM and alternative myelopathy diagnoses were applied. All cases where any discrepancy was suspected from the final reported clinical diagnosis were reviewed by each author and a consensus final diagnosis was made. The diagnostic criteria for ITM were met in 41 of 226 patients (18.1%). In 158 patients (69.9%), an alternative specific myelopathy diagnosis was made: multiple sclerosis or clinically isolated syndrome, 75; vascular myelopathy, 41; neurosarcoidosis, 12; neuromyelitis optica spectrum disorder, 12; myelin oligodendrocyte glycoprotein myelopathy, 5; neoplastic, 4; compressive, 3; nutritional, 3; infectious, 2; and other, 2. A myelopathy was not confirmed in 27 patients. Time from symptom onset to final clinical diagnosis in patients without ITM was a median of 9 months (range 0-288). Fifty-five patients (24%) required treatment changes according to their final clinical diagnosis. The majority of patients with suspected ITM have an alternative specific myelopathy diagnosis. A presumptive diagnosis of ITM can lead to premature diagnostic conclusions affecting patient treatment. Copyright © 2017 American Academy of Neurology.

  9. Primary biliary cirrhosis complicated by transverse myelitis in a patient without Sjögren's syndrome

    Directory of Open Access Journals (Sweden)

    Micheli A

    2005-01-01

    Full Text Available Transverse myelitis is an acute inflammatory process, affecting one or more segments of the spinal cord. Its association with primary biliary cirrhosis has been documented in only four cases - all along with Sjögren's syndrome. Herein, we report for the first time, a patient who developed recurrent acute transverse myelitis in association with primary biliary cirrhosis without any clinical or histological indication of Sjögren's syndrome. A 42-year-old woman with primary biliary cirrhosis developed acute onset quadriparesis and urinary retention. Diagnostic evaluation excluded the presence of Sjögren's syndrome, other autoimmune syndromes, infections and multiple sclerosis. Magnetic resonance imaging of the spinal cord disclosed signal intensity abnormalities from C1 to T2 after gadolinium enhancement. As diagnosis of acute transverse myelitis was prominent, the patient was treated with intravenous methylprednisolone. The patient had a fair outcome despite an early recurrence of the symptoms after treatment withdrawal.

  10. Transverse Kerr effect in one-dimensional magnetophotonic crystals: Experiment and theory

    Energy Technology Data Exchange (ETDEWEB)

    Erokhin, S. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation)]. E-mail: yerokhin@magn.ru; Boriskina, Yu. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation); Vinogradov, A. [Institute for Theoretical and Applied Electrodynamics, Izhorskaya 13/19, 127412 Moscow (Russian Federation); Inoue, M. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1 Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Kobayashi, D. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1 Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Fedyanin, A. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation); Gan' shina, E. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation); Kochneva, M. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation); Granovsky, A. [Faculty of Physics, Lomonosov Moscow State University, 11992 Moscow (Russian Federation)

    2006-05-15

    Magneto-optical transverse Kerr and Faraday effects are studied experimentally and theoretically in one-dimensional magnetophotonic crystals fabricated from a stack of four repetitions of layers of Bi-substituted yttrium iron garnet and SiO{sub 2} layers. The results of theoretical calculations in the framework of modified matrices approach are consistent with the obtained experimental data with the exception of the one cusp at 480 nm in the transverse Kerr effect spectra. Possible mechanisms of this disagreement are discussed.

  11. Ultrashort pulse chirp measurement via transverse second-harmonic generation in strontium barium niobate crystal

    Energy Technology Data Exchange (ETDEWEB)

    Trull, J.; Wang, B.; Parra, A.; Vilaseca, R.; Cojocaru, C. [Departament de Física i Enginyeria Nuclear, Universitat Politècnica Catalunya, Terrassa 08222 (Spain); Sola, I. [Grupo de Investigación en Óptica Extrema (GIOE), Departamento de Física Aplicada, Universidad de Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain); Krolikowski, W. [Laser Physics Centre, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia); Science Program, Texas A and M University at Qatar, Doha (Qatar); Sheng, Y. [Laser Physics Centre, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia)

    2015-06-01

    Pulse compression in dispersive strontium barium niobate crystal with a random size and distribution of the anti-parallel orientated nonlinear domains is observed via transverse second harmonic generation. The dependence of the transverse width of the second harmonic trace along the propagation direction allows for the determination of the initial chirp and duration of pulses in the femtosecond regime. This technique permits a real-time analysis of the pulse evolution and facilitates fast in-situ correction of pulse chirp acquired in the propagation through an optical system.

  12. Ultrashort pulse chirp measurement via transverse second-harmonic generation in strontium barium niobate crystal

    International Nuclear Information System (INIS)

    Trull, J.; Wang, B.; Parra, A.; Vilaseca, R.; Cojocaru, C.; Sola, I.; Krolikowski, W.; Sheng, Y.

    2015-01-01

    Pulse compression in dispersive strontium barium niobate crystal with a random size and distribution of the anti-parallel orientated nonlinear domains is observed via transverse second harmonic generation. The dependence of the transverse width of the second harmonic trace along the propagation direction allows for the determination of the initial chirp and duration of pulses in the femtosecond regime. This technique permits a real-time analysis of the pulse evolution and facilitates fast in-situ correction of pulse chirp acquired in the propagation through an optical system

  13. Application of laser-optical diagnostics for the support of direct-injection gasoline combustion process development; Einsatz laseroptischer Messverfahren zur Unterstuetzung der Entwicklung von Brennverfahren mit Benzin-Direkteinspritzung

    Energy Technology Data Exchange (ETDEWEB)

    Hentschel, W.; Meyer, H.; Stiebels, B. [Volkswagenwerk AG, Wolfsburg (Germany). Abt. Forschung und Entwicklung

    2000-07-01

    The development of direct-injection gasoline engines at Volkswagen was supported strictly from the beginning by the means of optical diagnostics and CFD-simulations. Basic phenomena, such as the formation of the in-cylinder flow field, the penetration of the spray formed by a hollow-cone swirl-type injector at high fuel pressure, the interaction of spray and flow and the formation of an ignitable mixture were analysed in details. The paper describes the laser-optical techniques-particle-image-velocimetry, laser-Doppler-anemometry, videostroboscopy, high-speed cinematography and laser-induced fluorescence - which were used during the development of the DI gasoline combustion process. Examples taken from engines with optical access to the combustion chamber demonstrate the capability of the techniques and pinpoint where the design of the combustion process benefits from experimental and simulation investigations. (orig.) [German] Die Entwicklung von Ottomotoren mit Benzin-Direkteinspritzung wurde bei Volkswagen von Beginn an konsequent durch den Einsatz optischer Messverfahren und CFD-Simulationen unterstuetzt. Damit konnten grundlegende Phaenomene, wie die Ausbildung des Stroemungsfeldes im Motorbrennraum, die Ausbreitung des durch einen Hohlkegel-Drallinjektor unter hohem Druck eingespritzten Kraftstoffs sowie die Wechselwirkung der Luftstroemung im Zylinder mit den Einspritzstrahlen und die Bildung einer zuendfaehigen Ladungswolke detailliert untersucht werden. Das Paper beschreibt die laseroptischen Messverfahren - Particle-Image-Velocimetry, Laser-Doppler-Anemometry, Video-Stroboskopie, Hochgeschwindikgkeits-Kinematographie und Laserinduzierte Fluoreszenz - die bei der Brennverfahrensentwicklung eingesetzt werden und zeigt anhand einer Reihe von konkreten Beispielen, wo Antworten auf Grundsatzfragen zur Auslegung des Brennverfahrens durch Messergebnisse an optisch zugaenglichen Motoren und durch CFD-Simulationen erarbeitet werden koennen. (orig.)

  14. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  15. Carcinoma transverse colon masquerading as carcinoma gall bladder.

    Science.gov (United States)

    Munghate, Anand; Kumar, Ashwani; Singh, Harnam; Singh, Gurpreet; Singh, Bimaljot; Chauhan, Mahak

    2014-04-01

    Colorectal cancer is one of the most common cancer worldwide .Its incidence is reported to be increasing in developing countries. It commonly presents with weight loss, anaemia, lump abdomen, change of bowel habit, obstruction or fresh rectal bleeding. Beside these common modes of presentations, there are some rare manifestations which masqueraded as different disease like obstructive jaundice, empyema gall bladder or cholecystitis. A 60-year-old male presented to hospital with right sided pain abdomen. On abdominal examination mild tenderness was present in right hypochondrium. Intra operatively gall bladder was separated from the adjoining gut, peritoneum and liver bed and was removed. On further exploration, there was a large mass in the vicinity of the gall bladder related to transverse colon. Extended right hemicolectomy was done. Histopathological examination of gut mass revealed adenocarcinoma of transverse colon with free margins and gall bladder showed cholecystitis with no evidence of malignancy. We present an interesting case of colon cancer colon that caused diagnostic confusion by mimicking as cholecystitis. Colorectal cancer constitutes a major public health issue globally. Therefore, public awareness, screening of high-risk populations, early diagnosis and effective treatment and follow-up will help to reduce its occurance and further complications.

  16. Total transverse rupture of the duodenum after blunt abdominal trauma.

    Science.gov (United States)

    Pirozzi, Cesare; Di Marco, Carluccio; Loponte, Margherita; Savino, Grazia

    2014-05-11

    Complete transverse rupture of the duodenum as an isolated lesion in blunt trauma can be considered as exceptional. The aim of this report is to discuss diagnostic procedures and surgical options in such an infrequent presentation. We report on a 37 year old man who had a total transverse rupture of the duodenum after blunt abdominal trauma. Diagnosis was suspected after contrast enhanced CT scan and confirmed at laparotomy; duodenal rupture was repaired by an end to end duodenal-duodenal anastomosis, after Kocher maneuver. The patient had fast and complete recovery. A high index of suspicion is necessary for timely diagnosis. Multi detector contrast enhanced CT scan is the gold standard for that aim. Surgical management must be tailored on an individual basis, since many techniques are available for both reconstruction and duodenum decompression. Kocher maneuver is essential for complete inspection of the pancreatic duodenal block and for appropriate reconstruction. Management of isolated duodenal rupture can be difficult. Contrast enhanced TC scans is essential for timely diagnosis. Primary repair can be achieved by an end to end duodenum anastomosis after Kocher maneuver, although alternative techniques are available for tailored solutions. Complex duodenum decompression techniques are not mandatory.

  17. Optical diagnostics for the investigation of combustion in a single cylinder of a diesel engine; Dieselmoottorin yksittaeisen sylinterin palamistapahtuman tutkiminen optisilla menetelmillae

    Energy Technology Data Exchange (ETDEWEB)

    Kytoelae, J.; Leino, I. [Waertsilae Diesel International Ltd, Vaasa (Finland); Hernberg, R.; Vattulainen, J. [Tampere Univ. of Technology (Finland). Lab. of Plasma Technology

    1997-10-01

    To be able to develop diesel engines with further lower exhaust emission levels, it is necessary to understand the different phases of combustion process taking place in a single cylinder of a diesel engine. In this project optical, both non-imaging and imaging techniques have been developed to study the temporal spatial flame behaviour and flame temperature in Wartsila medium speed diesel engines. Temperature of the diesel flame is a critical parameter for thermal NO{sub x} formation. The colour temperature of the diffusion diesel flame as a function of time (crank angle) has been determined pyrometrically based on the black body incandescence of the flame contained soot. To obtain spatially and temporally resolved information of the combustion process, flame visualization using CCD-techniques have been performed. Diesel combustion has been recorded both using special light-intensified high speed video recording (3000 fps) and with non-intensified, short exposure CCD-imaging. (orig.)

  18. Sensitive Diagnostics for Chemically Reacting Flows

    KAUST Repository

    Farooq, Aamir

    2015-01-01

    This talk will feature latest diagnostic developments for sensitive detection of gas temperature and important combustion species. Advanced optical strategies, such as intrapulse chirping, wavelength modulation, and cavity ringdown are employed.

  19. Sensitive Diagnostics for Chemically Reacting Flows

    KAUST Repository

    Farooq, Aamir

    2015-11-02

    This talk will feature latest diagnostic developments for sensitive detection of gas temperature and important combustion species. Advanced optical strategies, such as intrapulse chirping, wavelength modulation, and cavity ringdown are employed.

  20. Transverse beam stability measurement and analysis for the SNS accumulator ring

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Zaipeng [University of Wisconsin-Madison, Madison, WI 53706-1691 (United States); Deibele, Craig, E-mail: deibele@ornl.gov [Oak Ridge National Laboratory, PO BOX 2008 MS6483, Oak Ridge, TN 37831-6461 (United States); Schulte, Michael J.; Hu, Yu-Hen [University of Wisconsin-Madison, Madison, WI 53706-1691 (United States)

    2015-07-11

    A field-programmable gate array (FPGA)-based transverse feedback damper system was implemented in the Spallation Neutron Source (SNS) accumulator ring with the intention to stabilize the electron–proton (e–p) instability in the frequency range of 1–300 MHz. The transverse feedback damper could also be used as a diagnostic tool by measuring the beam transfer function (BTF). An analysis of the BTF measurements provides the stability diagram for the production beam at SNS. This paper describes the feedback damper system and its setup as the BTF diagnostic tool. Experimental BTF results are presented and beam stability is analyzed by use of the BTF measurements for the SNS accumulator ring.

  1. Transverse beam stability measurement and analysis for the SNS accumulator ring

    International Nuclear Information System (INIS)

    Xie, Zaipeng; Deibele, Craig; Schulte, Michael J.; Hu, Yu-Hen

    2015-01-01

    A field-programmable gate array (FPGA)-based transverse feedback damper system was implemented in the Spallation Neutron Source (SNS) accumulator ring with the intention to stabilize the electron–proton (e–p) instability in the frequency range of 1–300 MHz. The transverse feedback damper could also be used as a diagnostic tool by measuring the beam transfer function (BTF). An analysis of the BTF measurements provides the stability diagram for the production beam at SNS. This paper describes the feedback damper system and its setup as the BTF diagnostic tool. Experimental BTF results are presented and beam stability is analyzed by use of the BTF measurements for the SNS accumulator ring

  2. Nucleon Spin Structure: Longitudinal and Transverse

    International Nuclear Information System (INIS)

    Chen, Jian-Ping

    2011-01-01

    Inclusive Deep-Inelastic Scattering (DIS) experiments have provided us with the most extensive information on the unpolarized and longitudinal polarized parton (quark and gluon) distributions in the nucleon. It has becoming clear that transverse spin and transverse momentum dependent distributions (TMDs) study are crucial for a more complete understanding of the nucleon structure and the dynamics of the strong interaction. The transverse spin structure and the TMDs are the subject of increasingly intense theoretical and experimental study recently. With a high luminosity electron beam facility, JLab has played a major role in the worldwide effort to study both the longitudinal and transverse spin structure. Highlights of recent results will be presented. With 12-GeV energy upgrade, JLab will provide the most precise measurements in the valence quark region to close a chapter in longitudinal spin study. JLab will also perform a multi-dimensional mapping of the transverse spin structure and TMDs in the valence quark region through Semi-Inclusive DIS (SIDIS) experiments, providing a 3-d partonic picture of the nucleon in momentum space and extracting the u and d quark tensor charges of the nucleon. The precision mapping of TMDs will also allow a detailed study of the quark orbital motion and its dynamics.

  3. Strange hadron production at low transverse momenta

    Science.gov (United States)

    Veres, Gábor I.; PHOBOS Collaboration; Back, B. B.; Baker, M. D.; Ballintijn, M.; Barton, D. S.; Becker, B.; Betts, R. R.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Decowski, M. P.; García, E.; Gburek, T.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Harrington, A. S.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Holynski, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Khan, N.; Kulinich, P.; Kuo, C. M.; Lee, J. W.; Lin, W. T.; Manly, S.; Mignerey, A. C.; Noell, A.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Roland, C.; Roland, G.; Sagerer, J.; Sarin, P.; Sawicki, P.; Sedykh, I.; Skulski, W.; Smith, C. E.; Steinberg, P.; Stephans, G. S. F.; Sukhanov, A.; Teng, R.; Tonjes, M. B.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wyslouch, B.; Zhang, J.

    2004-01-01

    Some of the latest results of the PHOBOS experiment from the \\sqrt{s_{NN}}= 200\\ GeV Au+Au data are discussed. Those relevant to strangeness production are emphasized. These observations relate to the nature of the matter created when heavy ions collide at the highest achieved energy. The invariant yields of strange and non-strange charged hadrons at very low transverse momentum have been measured, and used to differentiate between different dynamical scenarios. In the intermediate transverse momentum range, the measured ratios of strange and anti-strange kaons approach one, while the antibaryon to baryon ratio is still significantly less, independent of collision centrality and transverse momentum. At high transverse momenta, we find that central and peripheral Au+Au collisions produce similar numbers of charged hadrons per participant nucleon pair, rather than per binary nucleon-nucleon collision. Finally, we describe the upgrades of PHOBOS completed for the 2003 d+Au and p+p run, which extend the transverse momentum range over which particle identification is possible and, at the same time, implement a trigger system selective for high-pT particles.

  4. Reflective optical system for time-resolved electron bunch measurements at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Rosbach, K; Baehr, J [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Roensch-Schulenburg, J [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik

    2011-01-15

    The Photo-Injector Test facility at DESY, Zeuthen site (PITZ), produces pulsed electron beams with low transverse emittance and is equipped with diagnostic devices for measuring various electron bunch properties, including the longitudinal and transverse electron phase space distributions. The longitudinal bunch structure is recorded using a streak camera located outside the accelerator tunnel, connected to the diagnostics in the beam-line stations by an optical system of about 30 m length. This system mainly consists of telescopes of achromatic lenses, which transport the light pulses and image them onto the entrance slit of the streak camera. Due to dispersion in the lenses, the temporal resolution degrades during transport. This article presents general considerations for time-resolving optical systems as well as simulations and measurements of specific candidate systems. It then describes the development of an imaging system based on mirror telescopes which will improve the temporal resolution, with an emphasis on off-axis parabolic mirror systems working at unit magnification. A hybrid system of lenses and mirrors will serve as a proof of principle. (orig.)

  5. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  6. A note on fractional disjoint transversals in hypergraphs

    DEFF Research Database (Denmark)

    Henning, Michael A.; Yeo, Anders

    2017-01-01

    A transversal in a hypergraph H is a subset of vertices that has a nonempty intersection with every edge of H. A transversal family F of H is a family of (not necessarily distinct) transversals of H. The effective transversal-ratio of the family F is the ratio of the number of sets in F over the ...

  7. 46 CFR 154.174 - Transverse contiguous hull structure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Transverse contiguous hull structure. 154.174 Section... Equipment Hull Structure § 154.174 Transverse contiguous hull structure. (a) The transverse contiguous hull...) The transverse contiguous hull structure of a vessel having cargo containment systems with secondary...

  8. Inertial confinement fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1986-10-01

    The concept and goals of ICF will be briefly reviewed and the new 100 kJ class Nova laser facility will be described. Experimental results obtained to date with Nova will be summarized, and the discussions of diagnostics will use examples on the present capabilities of Nova and new developments that are underway. The classes of diagnostic systems to be discussed fall into three basic categories: optical, x-ray, and particle. Examples of highly space resolved, time resolved, and spectrally resolved techniques as well as schemes involving combinations of these capabilities will be presented. A brief summary of the sophisticated acquisition and analysis system in use for Nova data will be provided

  9. Diagnostics and structure

    International Nuclear Information System (INIS)

    Vial, J.C.

    1986-01-01

    The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation

  10. The transverse momenta in the exclusive reactions at intermediate energies a parameter to mesure the transversity

    International Nuclear Information System (INIS)

    Armenise, N.; Fogli Muciaccia, M.T.; Nuzzo, S.

    1977-01-01

    The definition of a parameter usefull to measure the transversity is given. Some reactions at 9GeV/c are examined and the channels are selected looking at the behaviour of global transverse momenta of the event. A few comparisons with other variables, used to select the channels characterized by different production processes are reported

  11. Comparison of extended hemicolectomy versus transverse colectomy in patients with cancer of the transverse colon.

    Science.gov (United States)

    van Rongen, I; Damhuis, R A M; van der Hoeven, J A B; Plaisier, P W

    2013-01-01

    Cancer of the transverse colon is rare and postoperative mortality tends to be high. Standard surgical treatment involves either extended hemicolectomy or transverse colectomy, depending on the location of the tumour. The aim of the present study was to compare postoperative mortality and five-year survival between these types of surgery. For this observational study, data on patients with a tumour of the transverse colon, treated by open resection in the Dordrecht Hospital from 1989 through 2003, were derived from the database of the regional cancer registry. Information on type of resection, tumour stage, complications, postoperative mortality (30-day) and survival was abstracted from the medical files. Patients with multi-organ surgery, (sub)total colectomy or stage IV disease were excluded from the analysis, leaving a total series of 103 patients. Transverse colectomy comprised one third of operations, predominantly involving partial resections. Postoperative mortality was 6% (2/34) after transverse colectomy and 7% (5/69) after extended hemicolectomy. Five-year survival was slightly higher for the hemicolectomy group (61% versus 50%), but this difference did not reach statistical significance (p = 0.34). Our results confirm the high postoperative risk after surgery for cancer of the transverse colon and show that this risk does not depend on the type of surgery. Considering the satisfactory results after partial transverse colectomy, segmental resections may be considered as an option for the treatment of localised tumours of the transverse colon.

  12. Laser Diagnostics for Reacting Flows

    Science.gov (United States)

    2010-01-11

    the high-temperature kinetics of n-heptane pyrolysis . The two-wavelength temperature and vapor concentration diagnostic designed for n- dodecane was...features ranging from 1338 nm to 1469 nm and one laser tuned to a CO2 transition near 1997 nm were combined onto a single mode optical fiber ( Corning

  13. Possibilities for reduction of transverse projected emittances by partial removal of transverse to longitudinal beam correlations

    International Nuclear Information System (INIS)

    Balandin, V.; Decking, W.; Golubeva, N.

    2014-09-01

    We show that if in the particle beam there are linear correlations between energy of particles and their transverse positions and momenta (linear beam dispersions), then the transverse projected emittances always can be reduced by letting the beam to pass through magnetostatic system with specially chosen nonzero lattice dispersions. The maximum possible reduction of the transverse projected emittances occurs when all beam dispersions are zeroed, and the values of the lattice dispersions required for that are completely defined by the values of the beam dispersions and the beam rms energy spread and are independent from any other second-order central beam moments. Besides that, we prove that, alternatively, one can also use the lattice dispersions to remove linear correlations between longitudinal positions of particles and their transverse coordinates (linear beam tilts), but in this situation solution for the lattice dispersions is nonunique and the reduction of the transverse projected emittances is not guaranteed.

  14. Curvature effects in two-dimensional optical devices inspired by transformation optics

    KAUST Repository

    Yuan, Shuhao; Zhang, Yongyou; Zhang, Qingyun; Zou, Bingsuo; Schwingenschlö gl, Udo

    2016-01-01

    Light transport in curved quasi two-dimensional waveguides is considered theoretically. Within transformation optics and tensor theory, a concise description of curvature effects on transverse electric and magnetic waves is derived. We show

  15. Directional Transverse Oscillation Vector Flow Estimation

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2017-01-01

    A method for estimating vector velocities using transverse oscillation (TO) combined with directional beamforming is presented. In Directional Transverse Oscillation (DTO) a normal focused field is emitted and the received signals are beamformed in the lateral direction transverse to the ultrasound...... beam to increase the amount of data for vector velocity estimation. The approach is self-calibrating as the lateral oscillation period is estimated from the directional signal through a Fourier transform to yield quantitative velocity results over a large range of depths. The approach was extensively...... simulated using Field IIpro and implemented on the experimental SARUS scanner in connection with a BK Medical 8820e convex array transducer. Velocity estimates for DTO are found for beam-to-flow angles of 60, 75, and 90, and vessel depths from 24 to 156 mm. Using 16 emissions the Standard Deviation (SD...

  16. Spin versus helicity in processes involving transversity

    CERN Document Server

    Mekhfi, Mustapha

    2011-01-01

    We construct the spin formalism in order to deal in a direct and natural way with processes involving transversity which are now of increasing popularity. The helicity formalism which is more appropriate for collision processes of definite helicity has been so far used also to manage processes with transversity, but at the price of computing numerous helicity amplitudes generally involving unnecessary kinematical variables.In a second step we work out the correspondence between both formalisms and retrieve in another way all results of the helicity formalism but in simpler forms.We then compute certain processes for comparison.A special process:the quark dipole magnetic moment is shown to be exclusively treated within the spin formalism as it is directly related to the transverse spin of the quark inside the baryon.

  17. Operative Method for Transverse Colon Carcinoma: Transverse Colectomy Versus Extended Colectomy.

    Science.gov (United States)

    Chong, Choon Seng; Huh, Jung Wook; Oh, Bo Young; Park, Yoon Ah; Cho, Yong Beom; Yun, Seong Hyeon; Kim, Hee Cheol; Lee, Woo Yong

    2016-07-01

    The type of surgery performed for primary transverse colon cancer varies based on tumor characteristics and surgeon perspective. The optimal oncological outcome following different surgical options has not been clearly established, and transverse colectomy has shown oncological equivalence only in small cohort studies. Our aim was to compare long-term oncological outcomes after transverse colectomy versus extended resection for transverse colon cancer. This study is a retrospective review of prospectively collected data. This study was conducted at a tertiary care hospital. All patients treated for transverse colon cancer at the Samsung Medical Center between 1995 and 2013 were included. Oncological outcomes were compared between 2 groups of patients: a transverse colectomy group and an extended colectomy group (which included extended right hemicolectomy and left hemicolectomy). A total of 1066 patients were included, of whom 750 (70.4%) underwent extended right hemicolectomy, 127 (11.9%) underwent transverse colectomy, and 189 (17.7%) underwent left hemicolectomy. According to univariate analysis, surgical approach, histological type, tumor morphology, cancer T and N stage, cancer size, and lymphovascular invasion were significant factors contributing to disease-free survival (DFS). However, as seen in multivariate analysis, only node-positive disease (HR = 2.035 (1.188-3.484)), tumors with ulcerative morphology (HR = 3.643 (1.132-11.725)), and the presence of vascular invasion (HR = 2.569 (1.455-4.538)) were significant factors for DFS. Further analysis with a propensity-matched cohort between the transverse and extended colectomy groups demonstrated no significant differences in DFS and overall survival. This study was limited because it was performed at a single institution and it was retrospective in nature. In terms of perioperative and oncological outcomes, transverse colectomy and extended colectomy did not differ despite a shorter specimen length and

  18. Pepper-pot diagnostic method to define emittance and Twiss parameters on low energies accelerators

    CERN Document Server

    Dolinska, M E

    2002-01-01

    The new complex mathematical algorithm to determine beam transverse emittance data and the Twiss parameters from intensity measured with pepper-por diagnostic device on rf low energies accelerators is described.

  19. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    International Nuclear Information System (INIS)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-01-01

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin

  20. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  1. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Science.gov (United States)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-12-01

    The "Commissariat à l'énergie atomique et aux énergies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  2. Investigation of non-premixed flame combustion characters in GO2/GH2 shear coaxial injectors using non-intrusive optical diagnostics

    Science.gov (United States)

    Dai, Jian; Yu, NanJia; Cai, GuoBiao

    2015-12-01

    Single-element combustor experiments are conducted for three shear coaxial geometry configuration injectors by using gaseous oxygen and gaseous hydrogen (GO2/GH2) as propellants. During the combustion process, several spatially and timeresolved non-intrusive optical techniques, such as OH planar laser induced fluorescence (PLIF), high speed imaging, and infrared imaging, are simultaneously employed to observe the OH radical concentration distribution, flame fluctuations, and temperature fields. The results demonstrate that the turbulent flow phenomenon of non-premixed flame exhibits a remarkable periodicity, and the mixing ratio becomes a crucial factor to influence the combustion flame length. The high speed and infrared images have a consistent temperature field trend. As for the OH-PLIF images, an intuitionistic local flame structure is revealed by single-shot instantaneous images. Furthermore, the means and standard deviations of OH radical intensity are acquired to provide statistical information regarding the flame, which may be helpful for validation of numerical simulations in future. Parameters of structure configurations, such as impinging angle and oxygen post thickness, play an important role in the reaction zone distribution. Based on a successful flame contour extraction method assembled with non-linear anisotropic diffusive filtering and variational level-set, it is possible to implement a fractal analysis to describe the fractal characteristics of the non-premixed flame contour. As a result, the flame front cannot be regarded as a fractal object. However, this turbulent process presents a self-similarity characteristic.

  3. Analysis of Transition from HCCI to CI via PPC with Low Octane Gasoline Fuels Using Optical Diagnostics and Soot Particle Analysis

    KAUST Repository

    An, Yanzhao; Vallinayagam, R; Vedharaj, S; Masurier, Jean-Baptiste; Dawood, Alaaeldin; Izadi Najafabadi, Mohammad; Somers, Bart; Johansson, Bengt

    2017-01-01

    In-cylinder visualization, combustion stratification, and engine-out particulate matter (PM) emissions were investigated in an optical engine fueled with Haltermann straight-run naphtha fuel and corresponding surrogate fuel. The combustion mode was transited from homogeneous charge compression ignition (HCCI) to conventional compression ignition (CI) via partially premixed combustion (PPC). Single injection strategy with the change of start of injection (SOI) from early to late injections was employed. The high-speed color camera was used to capture the in-cylinder combustion images. The combustion stratification was analyzed based on the natural luminosity of the combustion images. The regulated emission of unburned hydrocarbon (UHC), carbon monoxide (CO) and nitrogen oxides (NO) were measured to evaluate the combustion efficiency together with the in-cylinder rate of heat release. Soot mass concentration was measured and linked with the combustion stratification and the integrated red channel intensity of the high-speed images for the soot emissions. The nucleation nanoscale particle number and the particle size distribution were sampled to understand the effect of combustion mode switch.

  4. Analysis of Transition from HCCI to CI via PPC with Low Octane Gasoline Fuels Using Optical Diagnostics and Soot Particle Analysis

    KAUST Repository

    An, Yanzhao

    2017-10-10

    In-cylinder visualization, combustion stratification, and engine-out particulate matter (PM) emissions were investigated in an optical engine fueled with Haltermann straight-run naphtha fuel and corresponding surrogate fuel. The combustion mode was transited from homogeneous charge compression ignition (HCCI) to conventional compression ignition (CI) via partially premixed combustion (PPC). Single injection strategy with the change of start of injection (SOI) from early to late injections was employed. The high-speed color camera was used to capture the in-cylinder combustion images. The combustion stratification was analyzed based on the natural luminosity of the combustion images. The regulated emission of unburned hydrocarbon (UHC), carbon monoxide (CO) and nitrogen oxides (NO) were measured to evaluate the combustion efficiency together with the in-cylinder rate of heat release. Soot mass concentration was measured and linked with the combustion stratification and the integrated red channel intensity of the high-speed images for the soot emissions. The nucleation nanoscale particle number and the particle size distribution were sampled to understand the effect of combustion mode switch.

  5. Evolution of transverse modes in FELIX macropulses

    International Nuclear Information System (INIS)

    Weits, H.H.; Lin, L.; Werkhoven, G.H.C. van

    1995-01-01

    We present ringdown measurements of both the intracavity beam, using a low reflection beamsplitter, as well as the hole-outcoupled beam of FELIX, the intracavity measurements being taken at various sets of transverse coordinates. Recent measurements show a significant difference in the decay of the signals at different radial positions, suggesting the presence of higher order transverse modes. The formation of transverse modes depends on the properties of the cold cavity and its losses (i.e. resonator parameters, diffraction and outcoupling at the hole, absorption and edge losses on the mirrors, waveguide clipping), as well as on the gain mechanism. Both simulations with the axisymmetric ELIXER code and previous hole-outcoupled measurements indicated a substantial energy content of the 2nd or 4th Gauss-Laguerre (GL) mode for the 20-30 μm regime of FELIX. Moreover, as FELIX has a phase degenerate cavity, the fundamental and higher order transverse modes can interplay to create a reduced outcoupling efficiency at the hole. For example, in contrast to the decay rate of 13% per roundtrip that we would expect for a pure gaussian beam when we include a loss of 6% for the reflection at the intracavity beamsplitter, recent simulations indicate a decay rate as high as 23% of the hole-outcoupled signal. In this case the 2nd order GL mode contains 30% of the total intracavity power. The effect of transverse modes on subpulses in the limit cycle regime is an interesting aspect. As soon as a subpulse is losing contact with the electrons, its transverse pattern will exhibit an on-axis hole after a few roundtrips, according to the simulations. This process could mean that the subpulses are less pronounced in the hole-outcoupled signal of FELIX 1

  6. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  7. Statistics of optical vortex wander on propagation through atmospheric turbulence.

    Science.gov (United States)

    Gu, Yalong

    2013-04-01

    The transverse position of an optical vortex on propagation through atmospheric turbulence is studied. The probability density of the optical vortex position on a transverse plane in the atmosphere is formulated in weak turbulence by using the Born approximation. With these formulas, the effect of aperture averaging on topological charge detection is investigated. These results provide quantitative guidelines for the design of an optimal detector of topological charge, which has potential application in optical vortex communication systems.

  8. Ultra-broadband carpet cloak for transverse-electric polarization

    International Nuclear Information System (INIS)

    Deng, Ye; Xu, Su; Zhang, Runren; Zheng, Bin; Chen, Hongsheng; Chen, Hua; Yu, Faxin; Gao, Fei; Zhang, Baile

    2016-01-01

    Magnetism is a necessity in constructing macroscopic metamaterial invisibility cloaks that are theoretically designed by transformation optics, but will generally limit the cloaking bandwidth to an impractically narrow range. To meet the broad bandwidth demand, magnetism has been fully abandoned in previous demonstrations of macroscopic carpet cloaking, whose approach, however, cannot apply to a transverse-electric (TE) polarization. To fill this gap, here we experimentally demonstrate an ultra-broadband magnetic carpet cloak for the TE polarization. The cloak is made of non-resonant closed-ring metamaterials with little dispersion and the cloaking performance is confirmed with both time-domain simulation and frequency scanning measurement over a broad bandwidth corresponding to a pulse signal illumination. (paper)

  9. Ultra-broadband carpet cloak for transverse-electric polarization

    Science.gov (United States)

    Deng, Ye; Xu, Su; Zhang, Runren; Zheng, Bin; Chen, Hua; Gao, Fei; Yu, Faxin; Zhang, Baile; Chen, Hongsheng

    2016-04-01

    Magnetism is a necessity in constructing macroscopic metamaterial invisibility cloaks that are theoretically designed by transformation optics, but will generally limit the cloaking bandwidth to an impractically narrow range. To meet the broad bandwidth demand, magnetism has been fully abandoned in previous demonstrations of macroscopic carpet cloaking, whose approach, however, cannot apply to a transverse-electric (TE) polarization. To fill this gap, here we experimentally demonstrate an ultra-broadband magnetic carpet cloak for the TE polarization. The cloak is made of non-resonant closed-ring metamaterials with little dispersion and the cloaking performance is confirmed with both time-domain simulation and frequency scanning measurement over a broad bandwidth corresponding to a pulse signal illumination.

  10. Transversely Excited Multipass Photoacoustic Cell Using Electromechanical Film as Microphone

    Directory of Open Access Journals (Sweden)

    Jaakko Saarela

    2010-05-01

    Full Text Available A novel multipass photoacoustic cell with five stacked electromechanical films as a microphone has been constructed, tested and characterized. The photoacoustic cell is an open rectangular structure with two steel plates facing each other. The longitudinal acoustic resonances are excited transversely in an optical multipass configuration. A detection limit of 22 ppb (10−9 was achieved for flowing NO2 in N2 at normal pressure by using the maximum of 70 laser beams between the resonator plates. The corresponding minimum detectable absorption and the normalized noise-equivalent absorption coefficients were 2:2 × 10−7 cm−1 and 3:2 × 10−9 cm−1WHz−1/2, respectively.

  11. Study of a rare-gas transverse fast discharge

    Science.gov (United States)

    Chubb, D. L.; Michels, C. J.

    1979-01-01

    An experimental and analytical study of a Blumlein-type transverse fast discharge operating with He and Xe are presented. An electro-optical voltage probe was used to measure the discharge voltage, and the measured voltages were in agreement with the computed voltages. The analytical model was used to predict the dependence of the discharge efficiency for producing metastables and ions on the important plasma and external circuit parameters. In He the ion efficiency is greater than the metastable efficiency, while in Xe it is the opposite; the He ion efficiencies are much larger than in Xe, while Xe metastable efficiencies are much larger than in He. These differences between Xe and He are accounted by the large dissociative recombination rate of Xe compared with He.

  12. Inclusive eta production at large transverse momenta

    International Nuclear Information System (INIS)

    Donaldson, G.J.; Gordon, H.A.; Lai, K.; Stumer, I.; Barnes, A.V.; Mellema, D.J.; Tollestrup, A.V.; Walker, R.L.; Dahl, O.; Johnson, R.; Ogawa, A.; Pripstein, M.; Shannon, S.

    1978-01-01

    We have measured the ratio of inclusive production of eta to π 0 at transverse momenta above 1.5 GeV/c. Results are presented for various meson and proton beams with momenta of 100, 200, and 300 GeV/c incident upon a hydrogen target. The eta/π 0 production ratio is found to be independent of incident beam momentum and of the transverse and longitudinal momenta of production. The ratio for pion- and proton-induced reactions is 0.44 +- 0.05; for kaons, it is 0.74 +- 0.12

  13. Transverse posterior element fractures associated with torsion

    International Nuclear Information System (INIS)

    Abel, M.S.

    1989-01-01

    Six examples of a previously undescribed class of transverse vertebral element fractures are presented. These fractures differ from Chance and Smith fractures and their variants in the following respects: (1) the etiology is torsion and not flexion; (2) there is neither distraction of posterior ring fragments nor posterior ligament tears; (3) in contrast to Chance and Smith fractures, extension of the fracture into the vertebral body is absent or minimal; (4) the transverse process of the lumbar vertebra is avulsed at its base with a vertical fracture, not split horizontally. These fractures occur in cervical, lumbar, and sacral vertebrae in normal or compromised areas of the spine. (orig.)

  14. Fiber optics in SHIVA

    International Nuclear Information System (INIS)

    Severyn, J.; Parker, J.

    1978-01-01

    SHIVA is a twenty arm laser which is controlled with a network of fifty computers, interconnected with digital fiber optic links. Three different fiber optic systems employed on the Shiva laser will be described. Two of the systems are for digital communications, one at 9600 baud and the other at 1 megabaud. The third system uses fiber optics to distribute diagnostic triggers with subnanosecond jitter

  15. Advances in optical imaging

    International Nuclear Information System (INIS)

    Bremer, C.; Ntziachristos, V.; Mahmood, U.; Tung, C.H.; Weissleder, R.

    2001-01-01

    Different optical imaging technologies have significantly progressed over the last years. Besides advances in imaging techniques and image reconstruction, new 'smart' optical contrast agents have been developed which can be used to detect molecular targets (such as endogenous enzymes) in vivo. The combination of novel imaging technologies coupled with smart agents bears great diagnostic potential both clinically and experimentally. This overview outlines the basic principles of optical imaging and summarizes the current state of the art. (orig.) [de

  16. Longitudinal and transverse structure functions in decaying nearly homogeneous and isotropic turbulence

    International Nuclear Information System (INIS)

    Ahmad Imtiaz; Lu Zhi-Ming; Liu Yu-Lu

    2014-01-01

    Streamwise evolution of longitudinal and transverse velocity structure functions in a decaying homogeneous and nearly isotropic turbulence is reported for Reynolds numbers Re λ up to 720. First, two theoretical relations between longitudinal and transverse structure functions are examined in the light of recently derived relations and the results show that the low-order transverse structure functions can be well approximated by longitudinal ones within the sub-inertial range. Reconstruction of fourth-order transverse structure functions with a recently proposed relation by Grauer et al. is comparatively less valid than the relation already proposed by Antonia et al. Secondly, extended self-similarity methods are used to measure the scaling exponents up to order eight and the streamwise evolution of scaling exponents is explored. The scaling exponents of longitudinal structure functions are, at first location, close to Zybin's model, and at the fourth location, close to She—Leveque model. No obvious trend is found for the streamwise evolution of longitudinal scaling exponents, whereas, on the contrary, transverse scaling exponents become slightly smaller with the development of a steamwise direction. Finally, the stremwise variation of the order-dependent isotropy ratio indicates the turbulence at the last location is closer to isotropic than the other three locations. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  17. MIA analysis of FPGA BPMs and beam optics at APS

    Science.gov (United States)

    Ji, Da-Heng; Wang, Chun-Xi; Qin, Qing

    2012-11-01

    Model independent analysis, which was developed for high precision and fast beam dynamics analysis, is a promising diagnostic tool for modern accelerators. We implemented a series of methods to analyze the turn-by-turn BPM data. Green's functions corresponding to the local transfer matrix elements R12 or R34 are extracted from BPM data and fitted with the model lattice using least-square fitting. Here, we report experimental results obtained from analyzing the transverse motion of a beam in the storage ring at the Advanced Photon Source. BPM gains and uncoupled optics parameters are successfully determined. Quadrupole strengths are adjusted for fitting but can not be uniquely determined in general due to an insufficient number of BPMs.

  18. Optical Polarizationin Biomedical Applications

    CERN Document Server

    Tuchin, Valery V; Zimnyakov, Dmitry A

    2006-01-01

    Optical Polarization in Biomedical Applications introduces key developments in optical polarization methods for quantitative studies of tissues, while presenting the theory of polarization transfer in a random medium as a basis for the quantitative description of polarized light interaction with tissues. This theory uses the modified transfer equation for Stokes parameters and predicts the polarization structure of multiple scattered optical fields. The backscattering polarization matrices (Jones matrix and Mueller matrix) important for noninvasive medical diagnostic are introduced. The text also describes a number of diagnostic techniques such as CW polarization imaging and spectroscopy, polarization microscopy and cytometry. As a new tool for medical diagnosis, optical coherent polarization tomography is analyzed. The monograph also covers a range of biomedical applications, among them cataract and glaucoma diagnostics, glucose sensing, and the detection of bacteria.

  19. Dynamic focus optical coherence tomography: feasibility for improved basal cell carcinoma investigation

    Science.gov (United States)

    Nasiri-Avanaki, M. R.; Aber, Ahmed; Hojjatoleslami, S. A.; Sira, Mano; Schofield, John B.; Jones, Carole; Podoleanu, A. Gh.

    2012-03-01

    Basal cell carcinoma (BCC) is the most common form of skin cancer. To improve the diagnostic accuracy, additional non-invasive methods of making a preliminary diagnosis have been sought. We have implemented an En-Face optical coherence tomography (OCT) for this study in which the dynamic focus was integrated into it. With the dynamic focus scheme, the coherence gate moves synchronously with the peak of confocal gate determined by the confocal interface optics. The transversal resolution is then conserved throughout the depth range and an enhanced signal is returned from all depths. The Basal Cell Carcinoma specimens were obtained from the eyelid a patient. The specimens under went analysis by DF-OCT imaging. We searched for remarkable features that were visualized by OCT and compared these findings with features presented in the histology slices.

  20. The transition radiation. 2. experimental study of the optical transition radiation; Le rayonnement de transition: 2. etude experimentale du rayonnement de transition optique

    Energy Technology Data Exchange (ETDEWEB)

    Couillaud, Ch.; Haouat, G.; Seguin, S.; Striby, S

    1999-07-01

    Optical-transition-radiation-based diagnostics have been widely used for many years on electron accelerators in order to measure beam energy and transverse and longitudinal emittances. These diagnostics are very attractive for high brightness electron beams used as drivers for radiation sources. Such diagnostics have been performed on the ELSA facility (18 MeV electron energy, 100 A peak current) using both a single interface and an OTR-Wartski interferometer. We present the accelerator, the experimental set-up and the method for analyzing the OTR angular distribution. Then, the experimental results are described and compared with those from the three gradient method. In addition, we present a beam energy measurement using OTR interferogram analysis. (author)

  1. Optimal Surgery for Mid-Transverse Colon Cancer: Laparoscopic Extended Right Hemicolectomy Versus Laparoscopic Transverse Colectomy.

    Science.gov (United States)

    Matsuda, Takeru; Sumi, Yasuo; Yamashita, Kimihiro; Hasegawa, Hiroshi; Yamamoto, Masashi; Matsuda, Yoshiko; Kanaji, Shingo; Oshikiri, Taro; Nakamura, Tetsu; Suzuki, Satoshi; Kakeji, Yoshihiro

    2018-04-02

    Although the feasibility and safety of laparoscopic surgery for transverse colon cancer have been shown by the recent studies, the optimal laparoscopic approach for mid-transverse colon cancer is controversial. We retrospectively analyzed the data of patients with the mid-transverse colon cancer at our institutions between January 2007 and April 2017. Thirty-eight and 34 patients who received extended right hemicolectomy and transverse colectomy, respectively, were enrolled. There were no significant differences in operating time, blood loss, and hospital stay between the two groups. Postoperative complications developed in 10 of 34 patients (29.4%; wound infection: 2 cases, anastomotic leakage: 2 cases, bowel obstruction: 1 case, incisional hernia: 2 cases, others: 3 cases) for the transverse colectomy group and in 4 of 38 patients (10.5%; wound infection: 1 case, anastomotic leakage: 0 case, bowel obstruction: 2 cases, incisional hernia: 0 case, others: 1 case) for the extended right hemicolectomy group (P = 0.014). Although the median number of harvested #221 and #222 LNs was similar between the two groups (6 vs. 8, P = 0.710, and 3 vs. 2, P = 0.256, respectively), that of #223 was significantly larger in extended right hemicolectomy than in transverse colectomy (3 vs. 1, P = 0.038). The 5-year disease-free and overall survival rates were 92.4 and 90.3% for the extended right hemicolectomy group, and 95.7 and 79.6% for the transverse colectomy group (P = 0.593 and P = 0.638, respectively). Laparoscopic extended right hemicolectomy and laparoscopic transverse colectomy offer similar oncological outcomes for mid-transverse colon cancer. Laparoscopic extended right hemicolectomy might be associated with fewer postoperative complications.

  2. Idiopathic intracranial hypertension and transverse sinus stenoses

    DEFF Research Database (Denmark)

    Skyrman, Simon; Fytagoridis, Anders; Andresen, Morten

    2013-01-01

    An 18-year-old woman was diagnosed with idiopathic intracranial hypertension (IIH) and bilateral transverse sinus stenoses (TSS), after presenting with papilledema and decreased visual acuity. Lumbar puncture revealed an opening pressure of >60 cm H2O. MRI showed bilateral TSS believed to be asso...

  3. What is the transverse momentum of partons

    International Nuclear Information System (INIS)

    Close, F.E.; Halzen, F.; Scott, D.M.

    1977-01-01

    Theoretical arguments for a picture where the average transverse momentum of partons inside hadrons increases when x increases towards x=0.4 approximately 0.5, peaks and subsequently decreases when x approaches 1. This result is contrary to that suggested by asymptotic freedom arguments. Phenomenological support for this is discussed. (Auth.)

  4. Transverse tripolar stimulation for selective FNS

    NARCIS (Netherlands)

    Deurloo, K.E.I.; Holsheimer, J.

    1996-01-01

    Various anode-cathode configurations in a nerve cuff were modeled in order to optimize its spatial selectivity characteristics for FNS. Apart from the usual configurations (monopole, bipole, longitudinal tripole, ¿steering¿ anode), a transverse tripolar configuration (central cathode) was examined.

  5. TRANSVERSE COLON POUCH: AN ALTERNATIVE TO ...

    African Journals Online (AJOL)

    Objective Urinary diversion after pelvic irradiation is challenging. The use of irradiated bowel is mostly complicated and unsuccessful. Therefore, the use of an exclusively non-irradiated bowel segment, such as the transverse colon, is a good alternative in such situation. Patients and Methods Twenty-nine female patients ...

  6. Rapid communication: Transverse spin with coupled plasmons

    Indian Academy of Sciences (India)

    Samyobrata Mukherjee

    2017-07-25

    Jul 25, 2017 ... spline interpolation from the data of Johnson and Christy. [31]. But first, we have to deal with normalization in order to make our comparisons of the transverse spin for different wavelengths and metal film thicknesses d meaningful. We normalize the power flow into the sys- tem at x = 0 to unity. ∫ ∞. −∞.

  7. Sex Education as a Transversal Subject

    Science.gov (United States)

    Rabelo, Amanda Oliveira; Pereira, Graziela Raupp; Reis, Maria Amélia; Ferreira, António G.

    2015-01-01

    Currently, sex education is in many countries a transversal subject, in which the school becomes a privileged place for the implementation of policies that aim at promoting "public health." Its design as a cross-cutting subject envisages fostering the dissemination of these subjects in all pedagogical and curricular fields; however, we…

  8. Nuclear transverse sectional brain function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1978-01-01

    A transverse radionuclide scanfield imaging apparatus is described comprising a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; and means for imparting travel to the collimators such that the focal point of each collimator uniformly samples at least one half of the scan field

  9. Wide-field absolute transverse blood flow velocity mapping in vessel centerline

    Science.gov (United States)

    Wu, Nanshou; Wang, Lei; Zhu, Bifeng; Guan, Caizhong; Wang, Mingyi; Han, Dingan; Tan, Haishu; Zeng, Yaguang

    2018-02-01

    We propose a wide-field absolute transverse blood flow velocity measurement method in vessel centerline based on absorption intensity fluctuation modulation effect. The difference between the light absorption capacities of red blood cells and background tissue under low-coherence illumination is utilized to realize the instantaneous and average wide-field optical angiography images. The absolute fuzzy connection algorithm is used for vessel centerline extraction from the average wide-field optical angiography. The absolute transverse velocity in the vessel centerline is then measured by a cross-correlation analysis according to instantaneous modulation depth signal. The proposed method promises to contribute to the treatment of diseases, such as those related to anemia or thrombosis.

  10. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  11. Radiation hardening of diagnostics

    International Nuclear Information System (INIS)

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10 16 neutrons per second because of ''spallation'' reactions when the protons collide with the copper nuclei in the beam stop

  12. Fluorescence optical imaging and musculoskeletal ultrasonography in juvenile idiopathic polyarticular disease before and during antirheumatic treatment - a multicenter non-interventional diagnostic evaluation.

    Science.gov (United States)

    Klein, Ariane; Just, Georg Werner; Werner, Stephanie Gabriele; Oommen, Prasad T; Minden, Kirsten; Becker, Ingrid; Langer, Hans-Eckhard; Klee, Dirk; Horneff, Gerd

    2017-06-30

    Valid detection of inflamed joints is essential for correct classification, therapeutic decisions, prognosis and assessment of treatment efficacy in juvenile idiopathic arthritis (JIA). Fluorescence optical imaging (FOI) enables visualization of inflammation in arthritis of finger and hand joints and might be used for monitoring. A 24-week observational study in polyarticular JIA patients newly starting treatment with methotrexate or an approved biologic was performed in three centers. Patients were evaluated clinically, by gray-scale ultrasonography (GSUS), power-Doppler ultrasonography (PDUS) and FOI at baseline, week 12 and week 24. Of 37 patients enrolled, 24 patients started methotrexate and 13 patients a biologic for the first time (etanercept n = 11, adalimumab and tocilizumab n = 1 each). Mean JADAS 10 decreased significantly from 17.7 at baseline to 12.2 and 7.2 at week 12 and 24 respectively. PedACR 30/50/70/100 response rates at week 24 were 85%/73%/50%/27%. The total number of clinically active joints in hand and fingers at baseline/week 12/week 24 was 262 (23.6%)/162 (16.4%)/162 (9.0%). By GSUS, at baseline/week 12/week 24, 192 (19.4%)/135 (16.1%)/83 (11.5%) joints showed effusions and 186 (18.8%)/107 (12.7%)/69 (9.6%) showed synovial thickening, and by PDUS 68 (6.9%)/15 (1.8%)/36 (5%) joints showed hyperperfusion. Any sign of arthritis was detected by US in a total of 243 joints (24.5%) at baseline, 161 joints (19.2%) at week 12 and 123 joints (17%) at week 24. By FOI at baseline/week 12/week 24, 430 (38.7%)/280 (29.2%)/215 (27.6%) showed a signal enhancement in at least one phase. Summarizing all three points of time, the highest numbers of signals were detected by FOI with 32% of joints, especially in phase 2, while by US 20.7% and by clinical examination 17.5% of joints were active. A high number of joints (21.1%) had FOI signals but were inactive by clinical examination. A total 20.1% of joints with signals in FOI did not show effusion

  13. Electron beam based transversal profile measurements of intense ion beams

    International Nuclear Information System (INIS)

    El Moussati, Said

    2014-01-01

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  14. Mapping of moveout in tilted transversely isotropic media

    KAUST Repository

    Stovas, A.; Alkhalifah, Tariq Ali

    2013-01-01

    The computation of traveltimes in a transverse isotropic medium with a tilted symmetry axis tilted transversely isotropic is very important both for modelling and inversion. We develop a simple analytical procedure to map the traveltime function from a transverse isotropic medium with a vertical symmetry axis (vertical transversely isotropic) to a tilted transversely isotropic medium by applying point-by-point mapping of the traveltime function. This approach can be used for kinematic modelling and inversion in layered tilted transversely isotropic media. © 2013 European Association of Geoscientists & Engineers.

  15. Mapping of moveout in tilted transversely isotropic media

    KAUST Repository

    Stovas, A.

    2013-09-09

    The computation of traveltimes in a transverse isotropic medium with a tilted symmetry axis tilted transversely isotropic is very important both for modelling and inversion. We develop a simple analytical procedure to map the traveltime function from a transverse isotropic medium with a vertical symmetry axis (vertical transversely isotropic) to a tilted transversely isotropic medium by applying point-by-point mapping of the traveltime function. This approach can be used for kinematic modelling and inversion in layered tilted transversely isotropic media. © 2013 European Association of Geoscientists & Engineers.

  16. Lateral phase drift of the topological charge density in stochastic optical fields

    CSIR Research Space (South Africa)

    Roux, FS

    2012-03-01

    Full Text Available The statistical distributions of optical vortices or topological charge in stochastic optical fields can be inhomogeneous in both transverse directions. Such two-dimensional inhomogeneous vortex or topological charge distributions evolve in a...

  17. Selection of unstable patterns and control of optical turbulence by Fourier plane filtering

    DEFF Research Database (Denmark)

    Mamaev, A.V.; Saffman, M.

    1998-01-01

    We report on selection and stabilization of transverse optical patterns in a feedback mirror experiment. Amplitude filtering in the Fourier plane is used to select otherwise unstable spatial patterns. Optical turbulence observed for nonlinearities far above the pattern formation threshold...

  18. Optics and Plasma Research Department annual progress report for 2004

    OpenAIRE

    Bindslev, Henrik; Lynov, Jens-Peter; Pedersen, C.; Petersen, Paul Michael; Skaarup, Bitten

    2005-01-01

    The Optics and Plasma Research Department performs basic and applied research within three scientific programmes: (1) laser systems and optical materials, (2) optical diagnostics and information processing and (3) plasma physics and technology. Thedepartment has core competencies in optical sensors, optical materials, biophotonics, fusion plasma physics, and industrial plasma technology. The department employs key technologies in micro- and nanotechnology for optical systems, temperaturecalib...

  19. In-Situ Measurement of the Transversal Dispersion in Ordered and Disordered 2D-pillar Beds for Liquid Chromatography

    NARCIS (Netherlands)

    de Bruyne, S.; de Malsche, Wim; Deridder, S.; Gardeniers, Johannes G.E.; Desmet, G.

    2014-01-01

    Using a fully transparent micropillar array chip and an optical “injection” setup capable of writing pulsed and continuous patterns into the flow by uncaging a fluorescent dye, highly detailed measurements of the transversal dispersion process in two-dimensional (2D) chromatographic beds could be

  20. Diagnostics for environmental aspects of pulsed atmospheric discharges

    International Nuclear Information System (INIS)

    Rutgers, W.R.; Veldhuizen, E.M. van

    2001-01-01

    Diagnostics for the study of pulsed atmospheric discharges are discussed. To obtain parameters for describing conversion processes of pollutants into harmless products many diagnostic techniques are in use and under development. In this contribution electrical, optical and chemical diagnostics used in air and wastewater remediation are reviewed