WorldWideScience

Sample records for transverse extraction ion

  1. Chemical Potentials of Quarks Extracted from Particle Transverse Momentum Distributions in Heavy Ion Collisions at RHIC Energies

    International Nuclear Information System (INIS)

    Zhao, Hong; Liu, Fu-Hu

    2014-01-01

    In the framework of a multisource thermal model, the transverse momentum distributions of charged particles produced in nucleus-nucleus (A-A) and deuteron-nucleus (d-A) collisions at relativistic heavy ion collider (RHIC) energies are investigated by a two-component revised Boltzmann distribution. The calculated results are in agreement with the PHENIX experimental data. It is found that the source temperature increases obviously with increase of the particle mass and incident energy, but it does not show an obvious change with the collision centrality. Then, the values of chemical potentials for up, down, and strange quarks can be obtained from the antiparticle to particle yield ratios in a wide transverse momentum range. The relationship between the chemical potentials of quarks and the transverse momentum with different centralities is investigated, too

  2. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fracti...

  3. Transverse flow of kaons in heavy-ion collisions

    CERN Document Server

    Zheng Yu Ming; Fuchs, C; Faessler, A; Xiao Wu; Hua Da Ping; Yan Yu Peng

    2002-01-01

    The transverse flow of positively charged kaons from heavy-ion collisions at intermediate energy is investigated within the framework of the quantum molecular dynamics model. The calculated results show that the experimental data are only consistent with those including the kaon mean-field potential from the chiral Lagrangian. This indicates that the transverse flow pattern of kaons is a useful probe of the kaon potential in a nuclear medium

  4. Observations of transverse ion acceleration in the topside auroral ionosphere

    International Nuclear Information System (INIS)

    Garbe, G.P.; Arnoldy, R.L.; Moore, T.E.; Kintner, P.M.; Vago, J.L.

    1992-01-01

    Data obtained from a sounding rocket flight which reached an apogee of 927 km and passed through several auroral arcs are reported. During portions of the flight when the rocket was not in an energetic auroral structure, the ion data are fit to a Maxwellian function which yields the plasma parameters. Throughout the middle portion of the flight when above 700 km altitude, ion distributions having a superthermal tail were measured. These ion distributions generally coexisted with a cold thermal core distribution and peaked at pitch angles slightly greater than 90 degree, which identifies them as conic distributions. These ions can be modeled using a bi-Maxwellian distribution function with a perpendicular (to B) temperature about 10 times greater than the parallel temperature of 0.15 eV. When the rocket was immersed in energetic auroral electron precipitation, two other ion distributions were observed. Transversely accelerated ions which represented bulk heating of the ambient population were observed. Transversely accelerated ions which represented bulk heating of the ambient population were observed continuously in these arcs. The characteristic perpendicular energy of the transversely bulk heated ions reached as high as 3 eV compared to typically less than 0.4 eV during nonauroral times. Cold ions flowing down the magnetic field were also continuously observed when the rocket was immersed in auroral electron precipitation and had downward speeds between 3 and 5 km/s. If one balances electric and collisional forces, these speeds translate to an electric field pointing into the atmosphere of magnitude 0.01 mV/m. A close correlation between auroral electron precipitation, measured electrostatic oxygen cyclotron waves, cold downflowing ions and transversely bulk heated ions will be shown

  5. Saturation of the ion transverse instability

    International Nuclear Information System (INIS)

    Heifets, S.

    1997-01-01

    Fast Ion Instability is studied in the nonlinear regime. It is shown that exponential growth of the linear regime is replaced in this case by the linear dependence on time. Numeric and analytical results are presented describing the beam profile and the beam spectrum in both regimes

  6. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S P; Jamieson, D N; Nugent, K W; Prawer, S [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  7. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S.P.; Jamieson, D.N.; Nugent, K.W.; Prawer, S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  8. Neutralization principles for the Extraction and Transport of Ion Beams

    CERN Document Server

    Riege, H

    2000-01-01

    The strict application of conventional extraction techniques of ion beams from a plasma source is characterized by a natural intensity limit determined by space charge.The extracted current may be enhanced far beyond this limit by neutralizing the space charge of the extracted ions in the first extraction gap of the source with electrons injected from the opposite side. The transverse and longitudinal emittances of a neutralized ion beam, hence its brightness, are preserved. Results of beam compensation experiments, which have been carried out with a laser ion source, are resumed for proposing a general scheme of neutralizing ion sources and their adjacent low-energy beam transport channels with electron beams. Many technical applications of high-mass ion beam neutralization technology may be identified: the enhancement of ion source output for injection into high-intensity, low-and high-energy accelerators, or ion thrusters in space technology, for the neutral beams needed for plasma heating of magnetic conf...

  9. Numerical simulation of plasma processes driven by transverse ion heating

    Science.gov (United States)

    Singh, Nagendra; Chan, C. B.

    1993-01-01

    The plasma processes driven by transverse ion heating in a diverging flux tube are investigated with numerical simulation. The heating is found to drive a host of plasma processes, in addition to the well-known phenomenon of ion conics. The downward electric field near the reverse shock generates a doublestreaming situation consisting of two upflowing ion populations with different average flow velocities. The electric field in the reverse shock region is modulated by the ion-ion instability driven by the multistreaming ions. The oscillating fields in this region have the possibility of heating electrons. These results from the simulations are compared with results from a previous study based on a hydrodynamical model. Effects of spatial resolutions provided by simulations on the evolution of the plasma are discussed.

  10. Electron beam based transversal profile measurements of intense ion beams

    International Nuclear Information System (INIS)

    El Moussati, Said

    2014-01-01

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  11. Distributed ion pump related transverse instability in CESR

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J T; Holmquist, T [Cornell Univ., Ithaca, NY (United States). Lab. of Nuclear Studies

    1996-08-01

    An anomalous damping or growth of transverse coupled bunch modes is observed in the Cornell Electron Storage Ring (CESR). The growth rates and tune shifts of these modes are a highly nonlinear function of current. Unlike an instability produced by the coupling impedance of the vacuum chamber, the magnitude of the growth rate first increases, then declines, as the beam current is increased. The effect is known to be related to the operation of the distributed ion pumps, as it disappears when the pumps are not powered. We review the observations of this effect, and show that it can be explained by the presence of electrons trapped in the CESR chamber by the field of the dipole magnets and the electrostatic leakage field of the distributed ion pumps. Photoelectrons are introduced into the chamber by synchrotron radiation and can be captured in or ejected from the chamber by the passage of the beam. The transverse position of the beam thus modulates the trapped photoelectron charge density, which in turn deflects the beam, creating growth or damping and a tune shift for each coupled bunch mode. Predictions of the dependence of growth rate and tune shift on bunch current and bunch pattern by a numerical model of this process are in approximate agreement with observations. (author)

  12. Transverse emittance studies of an induction accelerator of heavy ions

    International Nuclear Information System (INIS)

    Garvey, T.; Eylon, S.; Fessenden, T.J.; Hahn, K.; Henestroza, E.

    1991-01-01

    Current amplification of heavy ion beams is an integral feature of the induction linac approach to heavy ion fusion. As part of the Heavy Ion Fusion Accelerator Research program at LBL the authors have been studying the evolution of the transverse emittance of ion beams while they are undergoing current amplification, achieved by longitudinal bunch compression and acceleration. Experiments are conducted on MBE-4, a four beam Cs + induction linac. The space-charge dominated beams of MBE-4 are focused by electrostatic quadrupoles while they are accelerated from nominally 200 keV up to ∼ 1 MEV by 24 accelerating gaps. Initially the beams have currents of typically 4 mA to 10 mA per beam. Early experimental results showed a growth of the normalized emittance by a factor of 2 while the beam current was amplified by up to 9 times its initial value. The authors will discuss the results of recent experiments in which a mild bunch length compression rate, more typical of that required by a fusion driver, has shown that the normalized emittance can be maintained at its injection value (0.03 mm-mr) during acceleration

  13. A model for negative ion extraction and comparison of negative ion optics calculations to experimental results

    International Nuclear Information System (INIS)

    Pamela, J.

    1990-10-01

    Negative ion extraction is described by a model which includes electron diffusion across transverse magnetic fields in the sheath. This model allows a 2-Dimensional approximation of the problem. It is used to introduce electron space charge effects in a 2-D particle trajectory code, designed for negative ion optics calculations. Another physical effect, the stripping of negative ions on neutral gas atoms, has also been included in our model; it is found to play an important role in negative ion optics. The comparison with three sets of experimental data from very different negative ion accelerators, show that our model is able of accurate predictions

  14. Origin of transverse momentum in relativistic heavy-ion collisions: Microscopic study

    International Nuclear Information System (INIS)

    Blaettel, B.; Koch, V.; Lang, A.; Weber, K.; Cassing, W.; Mosel, U.

    1991-01-01

    We study the origin of the transverse momentum distribution in heavy-ion collisions within a relativistic transport approach. To achieve a better understanding of the reaction dynamics, we decompose the total p t distribution into a mean-field, N-N collision, and Fermi-momentum part. We find that the origin of the transverse momentum strongly depends on the rapidity region. Our investigation of the impact-parameter and mass dependence suggests that peripheral collisions may be useful to investigate the momentum dependence of the mean-field in the nucleus-nucleus case, whereas the mass dependence could give hints about the N-N-collision part. Only after these two issues are settled it may be possible to extract information about the density dependence in central collisions, which may, however, necessitate reactions at even higher energies than the 800 MeV/nucleon considered in this work

  15. The transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion

    Directory of Open Access Journals (Sweden)

    Devi Rianti

    2006-12-01

    Full Text Available A laboratoric experimental study was conducted on the transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion. The aim of this study is to know the difference of acrylic resin transverse strengths caused by immersion time variations in a concentrate solution. The study was carried out on unpolished acrylic resin plates with 65 × 10 × 2,5 mm dimension; solution with 15% Coleus amboinicus, Lour extract, and 30, 60, 90 days immersion times to measure the transverse strength and sterilized aquadest was used as control. Acrylic resin plates transverse strength was measured using Autograph AG-10 TE. The data was analyzed using One-Way Anova and LSD with 5% degree of significance. The result showed that longer immersion time will decrease the transverse strength of the acrylic resin plates. After 90 days immersion time, the transverse strength decrease is still above the recommended standard transverse strength.

  16. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    -ECR plasma source [3] with transversal magnetic filter for electron temperature control. 12 ECR plasma cells are placed 7.5 cm apart on the top of a cubic chamber 40x40x40 cm3. Each cell can be controlled independently by tuning the injected microwave power. The discharge is operated at pressures below 1 m......Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...

  17. IGUN-A program for the simulation of positive ion extraction including magnetic fields

    International Nuclear Information System (INIS)

    Becker, R.; Herrmannsfeldt, W.B.

    1992-01-01

    IGUN is a program for the simulation of positive ion extraction from plasmas. It is based on the well known program EGUN for the calculation of electron and ion trajectories in electron guns and lenses. The mathematical treatment of the plasma sheath is based on a simple analytical model, which provides a numerically stable calculation of the sheath potentials. In contrast to other ion extraction programs, IGUN is able to determine the extracted ion current in succeeding cycles of iteration by itself. However, it is also possible to set values of current, plasma density, or ion current density. Either axisymmetric or rectangular coordinates can be used, including axisymmetric or transverse magnetic fields

  18. igun - A program for the simulation of positive ion extraction including magnetic fields

    Science.gov (United States)

    Becker, R.; Herrmannsfeldt, W. B.

    1992-04-01

    igun is a program for the simulation of positive ion extraction from plasmas. It is based on the well known program egun for the calculation of electron and ion trajectories in electron guns and lenses. The mathematical treatment of the plasma sheath is based on a simple analytical model, which provides a numerically stable calculation of the sheath potentials. In contrast to other ion extraction programs, igun is able to determine the extracted ion current in succeeding cycles of iteration by itself. However, it is also possible to set values of current, plasma density, or ion current density. Either axisymmetric or rectangular coordinates can be used, including axisymmetric or transverse magnetic fields.

  19. Collective azimuthal alignment and transverse momentum conservation in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Bock, R.; Gutbrod, H.H.; Siemiarczuk, T.

    1987-08-01

    It is shown that transverse momentum conservation in the three-source Fai and Randrup statistical model does not explain the collective azimuthal alignment as observed in heavy-ion collisions at Bevelac energies. (orig.)

  20. Transverse confinement of an ion beam in a purely electrostatic configuration

    International Nuclear Information System (INIS)

    Correa, J.R.; Ordonez, C.A.; Weathers, D.L.

    2005-01-01

    The transverse confinement of an ion beam in a purely electrostatic configuration is studied. Analytical expressions for the electric potential of three different electrode configurations are found. Each configuration may be described as consisting of many closely spaced Einzel lenses, such that the focusing periodicity length is much smaller than the transverse size of the beam. Classical trajectory computer simulations are used to obtain a map of the phase space co-ordinates for which transverse electrostatic confinement occurs with one of the configurations. The results indicate that confinement should occur for a large range of conditions. It is speculated that the configurations studied can be used for transverse confinement of ion beams in either electrostatic ion traps or electrostatic ion storage rings

  1. Beam structure and transverse emittance studies of high-energy ion beams

    International Nuclear Information System (INIS)

    Saadatmand, K.; Johnson, K.F.; Schneider, J.D.

    1991-01-01

    A visual diagnostic technique has been developed to monitor and study ion beam structure shape and size along a transport line. In this technique, a commercially available fluorescent screen is utilized in conjunction with a video camera. This visual representation of the beam structure is digitized and enhanced through use of false-color coding and displayed on a TV monitor for on-line viewing. Digitized information is stored for further off-line processing (e.g., extraction of beam profiles). An optional wire grid placed upstream of the fluor screen adds the capability of transverse emittance (or angular spread) measurement to this technique. This diagnostic allows real-time observation of the beam response to parameter changes (e.g., evolution of the beam structure, shifts in the beam intensity at various spatial locations within the beam perimeter, and shifts in the beam center and position). 3 refs., 5 figs

  2. The transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion

    OpenAIRE

    Rianti, Devi

    2006-01-01

    A laboratoric experimental study was conducted on the transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion. The aim of this study is to know the difference of acrylic resin transverse strengths caused by immersion time variations in a concentrate solution. The study was carried out on unpolished acrylic resin plates with 65 × 10 × 2,5 mm dimension; solution with 15% Coleus amboinicus, Lour extract, and 30, 60, 90 days immersion times to measure the tra...

  3. Extraction of space-charge-dominated ion beams from an ECR ion source: Theory and simulation

    Science.gov (United States)

    Alton, G. D.; Bilheux, H.

    2004-05-01

    Extraction of high quality space-charge-dominated ion beams from plasma ion sources constitutes an optimization problem centered about finding an optimal concave plasma emission boundary that minimizes half-angular divergence for a given charge state, independent of the presence or lack thereof of a magnetic field in the extraction region. The curvature of the emission boundary acts to converge/diverge the low velocity beam during extraction. Beams of highest quality are extracted whenever the half-angular divergence, ω, is minimized. Under minimum half-angular divergence conditions, the plasma emission boundary has an optimum curvature and the perveance, P, current density, j+ext, and extraction gap, d, have optimum values for a given charge state, q. Optimum values for each of the independent variables (P, j+ext and d) are found to be in close agreement with those derived from elementary analytical theory for extraction with a simple two-electrode extraction system, independent of the presence of a magnetic field. The magnetic field only increases the emittances of beams through additional aberrational effects caused by increased angular divergences through coupling of the longitudinal to the transverse velocity components of particles as they pass though the mirror region of the electron cyclotron resonance (ECR) ion source. This article reviews the underlying theory of elementary extraction optics and presents results derived from simulation studies of extraction of space-charge dominated heavy-ion beams of varying mass, charge state, and intensity from an ECR ion source with emphasis on magnetic field induced effects.

  4. Extraction of space-charge-dominated ion beams from an ECR ion source: Theory and simulation

    International Nuclear Information System (INIS)

    Alton, G.D.; Bilheux, H.

    2004-01-01

    Extraction of high quality space-charge-dominated ion beams from plasma ion sources constitutes an optimization problem centered about finding an optimal concave plasma emission boundary that minimizes half-angular divergence for a given charge state, independent of the presence or lack thereof of a magnetic field in the extraction region. The curvature of the emission boundary acts to converge/diverge the low velocity beam during extraction. Beams of highest quality are extracted whenever the half-angular divergence, ω, is minimized. Under minimum half-angular divergence conditions, the plasma emission boundary has an optimum curvature and the perveance, P, current density, j +ext , and extraction gap, d, have optimum values for a given charge state, q. Optimum values for each of the independent variables (P, j +ext and d) are found to be in close agreement with those derived from elementary analytical theory for extraction with a simple two-electrode extraction system, independent of the presence of a magnetic field. The magnetic field only increases the emittances of beams through additional aberrational effects caused by increased angular divergences through coupling of the longitudinal to the transverse velocity components of particles as they pass though the mirror region of the electron cyclotron resonance (ECR) ion source. This article reviews the underlying theory of elementary extraction optics and presents results derived from simulation studies of extraction of space-charge dominated heavy-ion beams of varying mass, charge state, and intensity from an ECR ion source with emphasis on magnetic field induced effects

  5. Negative ion beam extraction in ROBIN

    International Nuclear Information System (INIS)

    Bansal, Gourab; Gahlaut, Agrajit; Soni, Jignesh; Pandya, Kaushal; Parmar, Kanu G.; Pandey, Ravi; Vuppugalla, Mahesh; Prajapati, Bhavesh; Patel, Amee; Mistery, Hiren; Chakraborty, Arun; Bandyopadhyay, Mainak; Singh, Mahendrajit J.; Phukan, Arindam; Yadav, Ratnakar K.; Parmar, Deepak

    2013-01-01

    Highlights: ► A RF based negative hydrogen ion beam test bed has been set up at IPR, India. ► Ion source has been successfully commissioned and three campaigns of plasma production have been carried out. ► Extraction system (35 kV) has been installed and commissioning has been initiated. Negative ion beam extraction is immediate milestone. -- Abstract: The RF based single driver −ve ion source experiment test bed ROBIN (Replica Of BATMAN like source in INDIA) has been set up at Institute for Plasma Research (IPR), India in a technical collaboration with IPP, Garching, Germany. A hydrogen plasma of density 5 × 10 12 cm −3 is expected in driver region of ROBIN by launching 100 kW RF power into the driver by 1 MHz RF generator. The cesiated source is expected to deliver a hydrogen negative ion beam of 10 A at 35 kV with a current density of 35 mA/cm 2 as observed in BATMAN. In first phase operation of the ROBIN ion source, a hydrogen plasma has been successfully generated (without extraction system) by coupling 80 kW RF input power through a matching network with high power factor (cos θ > 0.8) and different plasma parameters have been measured using Langmuir probes and emission spectroscopy. The plasma density of 2.5 × 10 11 cm −3 has been measured in the extraction region of ROBIN. For negative hydrogen ion beam extraction in second phase operation, extraction system has been assembled and installed with ion source on the vacuum vessel. The source shall be first operated in volume mode for negative ion beam extraction. The commissioning of the source with high voltage power supply has been initiated

  6. Longitudinal and transverse dynamics of ions from residual gas in an electron accelerator

    Science.gov (United States)

    Gamelin, A.; Bruni, C.; Radevych, D.

    2018-05-01

    The ion cloud produced from residual gas in an electron accelerator can degrade machine performances and produce instabilities. The ion dynamics in an accelerator is governed by the beam-ion interaction, magnetic fields and eventual mitigation strategies. Due to the fact that the beam has a nonuniform transverse size along its orbit, the ions move longitudinally and accumulate naturally at some points in the accelerator. In order to design effective mitigation strategies it is necessary to understand the ion dynamics not only in the transverse plane but also in the longitudinal direction. After introducing the physics behind the beam-ion interaction, we show how to get accumulation points for a realistic electron storage ring lattice. Simulations of the ion cloud dynamics, including the effect of magnetic fields on the ions, clearing electrodes and clearing gaps are shown. Longitudinal ion trapping due to the magnetic mirror effect in the dipole fringe fields is also detailed. Finally, the effectiveness of clearing electrode using longitudinal clearing fields is discussed and compared to clearing electrodes producing transverse field only.

  7. Ion extraction in the cyclotron geometry

    International Nuclear Information System (INIS)

    Rodenburg, R.E.

    1985-01-01

    The detailed physics of ion beam extraction from a plasma column by intense sinusoidal radio frequency (rf) electric fields at the ion cyclotron frequency omega/sub ci/ and its harmonics is experimentally studied. Results describe the instantaneous relationship - within one rf period of approx. = 3009 nsec - between applied rf, the plasma response and the ions expelled by rf and plasma fields. Reflex discharges in H 2 , D 2 , and He with ion and electron densities greater than or equal to10 11 cm -3 are subjected to 0-5 kV zero-to-peak rf electric fields E vector and 0.65-9.00 kG background magnetic fields B 0 vector with E vector perpendicular to B 0 vector. Ion currents up to 200 μA are extracted. Nonperturbing optical diagnostics measure the relative amplitude and phase of instantaneous ion and electron density fluctuations induced by the rf during each rf cycle and the time variation of extracted ion bursts, the latter made possible by the use of a phosphor beam-stop. Detailed dependences on external electric and magnetic fields are reported. The plasma density fluctuations are in good agreement with the dispersion relation for electrostatic ion cyclotron waves (EICW), and the beam data show current enhancement at the second harmonic over that at the fundamental and evidence for a radically different mechanism for the rf-driven ion extraction process than conventional wisdom assumes. This work represents the first detailed, systematic study of the ac ion extraction process

  8. Transverse Momentum Distribution of Vector Mesons Produced in Ultraperipheral Relativistic Heavy Ion Collisions

    International Nuclear Information System (INIS)

    Hencken, Kai; Baur, Gerhard; Trautmann, Dirk

    2006-01-01

    We study the transverse momentum distribution of vector mesons produced in ultraperipheral relativistic heavy ion collisions (UPCs). In UPCs there is no strong interaction between the nuclei, and the vector mesons are produced in photon-nucleus collisions where the (quasireal) photon is emitted from the other nucleus. Exchanging the role of both ions leads to interference effects. A detailed study of the transverse momentum distribution, which is determined by the transverse momentum of the emitted photon, the production process on the target, and the interference effect, is done. We study the unrestricted cross section and the one with an additional electromagnetic excitation of one or both ions; in the latter case small impact parameters are emphasized

  9. Transverse eV Ion Heating by Random Electric Field Fluctuations in the Plasmasphere

    Science.gov (United States)

    Artemyev, A. V.; Mourenas, D.; Agapitov, O. V.; Blum, L.

    2017-01-01

    Charged particle acceleration in the Earth inner magnetosphere is believed to be mainly due to the local resonant wave-particle interaction or particle transport processes. However, the Van Allen Probes have recently provided interesting evidence of a relatively slow transverse heating of eV ions at distances about 2-3 Earth radii during quiet times. Waves that are able to resonantly interact with such very cold ions are generally rare in this region of space, called the plasmasphere. Thus, non-resonant wave-particle interactions are expected to play an important role in the observed ion heating. We demonstrate that stochastic heating by random transverse electric field fluctuations of whistler (and possibly electromagnetic ion cyclotron) waves could explain this weak and slow transverse heating of H+ and O+ ions in the inner magnetosphere. The essential element of the proposed model of ion heating is the presence of trains of random whistler (hiss) wave packets, with significant amplitude modulations produced by strong wave damping, rapid wave growth, or a superposition of wave packets of different frequencies, phases, and amplitudes. Such characteristics correspond to measured characteristics of hiss waves in this region. Using test particle simulations with typical wave and plasma parameters, we demonstrate that the corresponding stochastic transverse ion heating reaches 0.07-0.2 eV/h for protons and 0.007-0.015 eV/h for O+ ions. This global temperature increase of the Maxwellian ion population from an initial Ti approx. 0.3 eV could potentially explain the observations.

  10. Transverse Schottky spectra and beam transfer functions of coasting ion beams with space charge

    International Nuclear Information System (INIS)

    Paret, Stefan

    2010-01-01

    A study of the transverse dynamics of coasting ion beams with moderate space charge is presented in this work. From the dispersion relation with linear space charge, an analytic model describing the impact of space charge on transverse beam transfer functions (BTFs) and the stability limits of a beam is derived. The dielectric function obtained in this way is employed to describe the transverse Schottky spectra with linear space charge as well. The difference between the action of space charge and impedances is highlighted. The setup and the results of an experiment performed in the heavy ion synchrotron SIS-18 at GSI to detect space-charge effects at different beam intensities are explicated. The measured transverse Schottky spectra and BTFs are compared with the linear space-charge model. The stability diagrams constructed from the BTFs are presented. The space-charge parameters evaluated from the Schottky and BTF measurements are compared with estimations based on measured beam parameters. The impact of collective effects on the Schottky and BTF diagnostics is also investigated through numerical simulations. For this purpose the self-field of beams with linear and non-linear transverse density-distributions is computed on a twodimensional grid. The noise of the random particle distribution causes fluctuations of the dipole moment of the beam which produce the Schottky spectrum. BTFs are simulated by exciting the beam with transverse kicks. The simulation results are used to verify the space-charge model. (orig.)

  11. Transverse Schottky spectra and beam transfer functions of coasting ion beams with space charge

    Energy Technology Data Exchange (ETDEWEB)

    Paret, Stefan

    2010-02-22

    A study of the transverse dynamics of coasting ion beams with moderate space charge is presented in this work. From the dispersion relation with linear space charge, an analytic model describing the impact of space charge on transverse beam transfer functions (BTFs) and the stability limits of a beam is derived. The dielectric function obtained in this way is employed to describe the transverse Schottky spectra with linear space charge as well. The difference between the action of space charge and impedances is highlighted. The setup and the results of an experiment performed in the heavy ion synchrotron SIS-18 at GSI to detect space-charge effects at different beam intensities are explicated. The measured transverse Schottky spectra and BTFs are compared with the linear space-charge model. The stability diagrams constructed from the BTFs are presented. The space-charge parameters evaluated from the Schottky and BTF measurements are compared with estimations based on measured beam parameters. The impact of collective effects on the Schottky and BTF diagnostics is also investigated through numerical simulations. For this purpose the self-field of beams with linear and non-linear transverse density-distributions is computed on a twodimensional grid. The noise of the random particle distribution causes fluctuations of the dipole moment of the beam which produce the Schottky spectrum. BTFs are simulated by exciting the beam with transverse kicks. The simulation results are used to verify the space-charge model. (orig.)

  12. Minijet thermalization and diffusion of transverse momentum correlation in high-energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Pang Longgang; Wang Qun; Wang Xinnian; Xu Rong

    2010-01-01

    Transverse momentum correlations in the azimuthal angle of hadrons produced owing to minijets are first studied within the HIJING Monte Carlo model in high-energy heavy-ion collisions. Quenching of minijets during thermalization is shown to lead to significant diffusion (broadening) of the correlation. Evolution of the transverse momentum density fluctuation that gives rise to this correlation in azimuthal angle in the later stage of heavy-ion collisions is further investigated within a linearized diffusion-like equation and is shown to be determined by the shear viscosity of the evolving dense matter. This diffusion equation for the transverse momentum fluctuation is solved with initial values given by HIJING and together with the hydrodynamic equation for the bulk medium. The final transverse momentum correlation in azimuthal angle is calculated along the freeze-out hypersurface and is found to be further diffused for higher values of the shear viscosity to entropy density ratio, η/s∼0.2-0.4. Therefore the final transverse momentum correlation in azimuthal angle can be used to study the thermalization of minijets in the early stage of heavy-ion collisions and the viscous effect in the hydrodynamic evolution of strongly coupled quark-gluon plasma.

  13. Simulation study on ion extraction from ECR ion sources

    International Nuclear Information System (INIS)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author)

  14. Simulation study on ion extraction from ECR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author).

  15. Generating unstable resonances for extraction schemes based on transverse splitting

    Directory of Open Access Journals (Sweden)

    M. Giovannozzi

    2009-02-01

    Full Text Available A few years ago, a novel multiturn extraction scheme was proposed, based on particle trapping inside stable resonances. Numerical simulations and experimental tests have confirmed the feasibility of such a scheme for low order resonances. While the third-order resonance is generically unstable and those higher than fourth order are generically stable, the fourth-order resonance can be either stable or unstable depending on the specifics of the system under consideration. By means of the normal form, a general approach to control the stability of the fourth-order resonance has been derived. This approach is based on the control of the amplitude detuning and the general form for a lattice with an arbitrary number of sextupole and octupole families is derived in this paper. Numerical simulations have confirmed the analytical results and have shown that, when crossing the unstable fourth-order resonance, the region around the center of the phase space is depleted and particles are trapped in only the four stable islands. A four-turn extraction could be designed using this technique.

  16. Failure in lithium-ion batteries under transverse indentation loading

    Science.gov (United States)

    Chung, Seung Hyun; Tancogne-Dejean, Thomas; Zhu, Juner; Luo, Hailing; Wierzbicki, Tomasz

    2018-06-01

    Deformation and failure of constrained cells and modules in the battery pack under transverse loading is one of the most common conditions in batteries subjected to mechanical impacts. A combined experimental, numerical and analytical approach was undertaken to reveal the underlying mechanism and develop a new cell failure model. When large format pouch cells were subjected to local indentation all the way to failure, the post-mortem examination of the failure zones beneath the punches indicates a consistent slant fracture surface angle to the battery plane. This type of behavior can be described by the critical fracture plane theory in which fracture is caused by the shear stress modified by the normal stress. The Mohr-Coulomb fracture criterion is then postulated and it is shown how the two material constants can be determined from just one indentation test. The orientation of the fracture plane is invariant with respect to the type of loading and can be considered as a property of the cell stack. In addition, closed-form solutions are derived for the load-displacement relation for both plane-strain and axisymmetric cases. The results are in good agreement with the numerical simulation of the homogenized model and experimentally measured responses.

  17. Ion temperature gradient driven mode in presence of transverse velocity shear in magnetized plasmas

    DEFF Research Database (Denmark)

    Chakrabarti, N.; Juul Rasmussen, J.; Michelsen, Poul

    2005-01-01

    The effect of sheared poloidal flow on the toroidal branch of the ion temperature gradient driven mode of magnetized nonuniform plasma is studied. A novel "nonmodal" calculation is used to analyze the problem. It is shown that the transverse shear flow considerably reduced the growth...

  18. Generating Unstable Resonances for Extraction Schemes Based on Transverse Splitting

    CERN Document Server

    Giovannozzi, M; Turchetti, G

    2009-01-01

    A few years ago, a novel multi-turn extraction scheme was proposed, based on particle trapping inside stable resonances. Numerical simulations and experimental tests have confirmed the feasibility of such a scheme for low order resonances. While the third-order resonance is generically unstable and those higher than fourth-order are generically stable, the fourth-order resonance can be either stable or unstable depending on the specifics of the system under consideration. By means of the Normal Form a general approach to control the stability of the fourth-order resonance has been derived. This approach is based on the control of the amplitude detuning and the general form for a lattice with an arbitrary number of sextupole and octupole families is derived in this paper. Numerical simulations have confirmed the analytical results and have shown that, when crossing the unstable fourth-order resonance, the region around the centre of the phase space is depleted and particles are trapped in only the four stable ...

  19. First Extraction of Transversity from a Global Analysis of Electron-Proton and Proton-Proton Data

    Science.gov (United States)

    Radici, Marco; Bacchetta, Alessandro

    2018-05-01

    We present the first extraction of the transversity distribution in the framework of collinear factorization based on the global analysis of pion-pair production in deep-inelastic scattering and in proton-proton collisions with a transversely polarized proton. The extraction relies on the knowledge of dihadron fragmentation functions, which are taken from the analysis of electron-positron annihilation data. For the first time, the transversity is extracted from a global analysis similar to what is usually done for the spin-averaged and helicity distributions. The knowledge of transversity is important for, among other things, detecting possible signals of new physics in high-precision low-energy experiments.

  20. Optimized simultaneous transverse and longitudinal focusing of intense ion beam pulses for warm dense matter applications

    International Nuclear Information System (INIS)

    Sefkow, Adam B.; Davidson, Ronald C.; Kaganovich, Igor D.; Gilson, Erik P.; Roy, Prabir K.; Seidl, Peter A.; Yu, Simon S.; Welch, Dale R.; Rose, David V.; Barnard, John J.

    2007-01-01

    Intense, space-charge-dominated ion beam pulses for warm dense matter and heavy ion fusion applications must undergo simultaneous transverse and longitudinal bunch compression in order to meet the requisite beam intensities desired at the target. The longitudinal compression of an ion bunch is achieved by imposing an initial axial velocity tilt on the drifting beam and subsequently neutralizing its space-charge and current in a drift region filled with high-density plasma. The Neutralized Drift Compression Experiment (NDCX) at Lawrence Berkeley National Laboratory has measured a sixty-fold longitudinal current compression of an intense ion beam with pulse duration of a few nanoseconds, in agreement with simulations and theory. A strong solenoid is modeled near the end of the drift region in order to transversely focus the beam to a sub-millimeter spot size coincident with the longitudinal focal plane. The charge and current neutralization provided by the background plasma is critical in determining the total achievable transverse and longitudinal compression of the beam pulse. Numerical simulations show that the current density of an NDCX ion beam can be compressed over a few meters by factors greater than 10 5 with peak beam density in excess of 10 14 cm -3 . The peak beam density sets a lower bound on the local plasma density required near the focal plane for optimal beam compression, since the simulations show stagnation of the compression when n beam >n plasma . Beam-plasma interactions can also have a deleterious effect on the compression physics and lead to the formation of nonlinear wave excitations in the plasma. Simulations that optimize designs for the simultaneous transverse and longitudinal focusing of an NDCX ion beam for future warm dense matter experiments are discussed

  1. Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources

    Science.gov (United States)

    Kuppel, S.; Matsushita, D.; Hatayama, A.; Bacal, M.

    2011-01-01

    This numerical study focuses on the physical mechanisms involved in the extraction of volume-produced H- ions from a steady state laboratory negative hydrogen ion source with one opening in the plasma electrode (PE) on which a dc-bias voltage is applied. A weak magnetic field is applied in the source plasma transversely to the extracted beam. The goal is to highlight the combined effects of the weak magnetic field and the PE bias voltage (upon the extraction process of H- ions and electrons). To do so, we focus on the behavior of electrons and volume-produced negative ions within a two-dimensional model using the particle-in-cell method. No collision processes are taken into account, except for electron diffusion across the magnetic field using a simple random-walk model at each time step of the simulation. The results show first that applying the magnetic field (without PE bias) enhances H- ion extraction, while it drastically decreases the extracted electron current. Secondly, the extracted H- ion current has a maximum when the PE bias is equal to the plasma potential, while the extracted electron current is significantly reduced by applying the PE bias. The underlying mechanism leading to the above results is the gradual opening by the PE bias of the equipotential lines towards the parts of the extraction region facing the PE. The shape of these lines is due originally to the electron trapping by the magnetic field.

  2. Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources

    International Nuclear Information System (INIS)

    Kuppel, S.; Matsushita, D.; Hatayama, A.; Bacal, M.

    2011-01-01

    This numerical study focuses on the physical mechanisms involved in the extraction of volume-produced H - ions from a steady state laboratory negative hydrogen ion source with one opening in the plasma electrode (PE) on which a dc-bias voltage is applied. A weak magnetic field is applied in the source plasma transversely to the extracted beam. The goal is to highlight the combined effects of the weak magnetic field and the PE bias voltage (upon the extraction process of H - ions and electrons). To do so, we focus on the behavior of electrons and volume-produced negative ions within a two-dimensional model using the particle-in-cell method. No collision processes are taken into account, except for electron diffusion across the magnetic field using a simple random-walk model at each time step of the simulation. The results show first that applying the magnetic field (without PE bias) enhances H - ion extraction, while it drastically decreases the extracted electron current. Secondly, the extracted H - ion current has a maximum when the PE bias is equal to the plasma potential, while the extracted electron current is significantly reduced by applying the PE bias. The underlying mechanism leading to the above results is the gradual opening by the PE bias of the equipotential lines towards the parts of the extraction region facing the PE. The shape of these lines is due originally to the electron trapping by the magnetic field.

  3. Source-to-target simulation of simultaneous longitudinal and transverse focusing of heavy ion beams

    Directory of Open Access Journals (Sweden)

    D. R. Welch

    2008-06-01

    Full Text Available Longitudinal bunching factors in excess of 70 of a 300-keV, 27-mA K^{+} ion beam have been demonstrated in the neutralized drift compression experiment [P. K. Roy et al., Phys. Rev. Lett. 95, 234801 (2005PRLTAO0031-900710.1103/PhysRevLett.95.234801] in rough agreement with particle-in-cell source-to-target simulations. A key aspect of these experiments is that a preformed plasma provides charge neutralization of the ion beam in the last one meter drift region where the beam perveance becomes large. The simulations utilize the measured ion source temperature, diode voltage, and induction-bunching-module voltage waveforms in order to determine the initial beam longitudinal phase space which is critical to accurate modeling of the longitudinal compression. To enable simultaneous longitudinal and transverse compression, numerical simulations were used in the design of the solenoidal focusing system that compensated for the impact of the applied velocity tilt on the transverse phase space of the beam. Complete source-to-target simulations, that include detailed modeling of the diode, magnetic transport, induction bunching module, and plasma neutralized transport, were critical to understanding the interplay between the various accelerator components in the experiment. Here, we compare simulation results with the experiment and discuss the contributions to longitudinal and transverse emittance that limit the final compression.

  4. Charged Particle, Photon Multiplicity, and Transverse Energy Production in High-Energy Heavy-Ion Collisions

    Directory of Open Access Journals (Sweden)

    Raghunath Sahoo

    2015-01-01

    Full Text Available We review the charged particle and photon multiplicities and transverse energy production in heavy-ion collisions starting from few GeV to TeV energies. The experimental results of pseudorapidity distribution of charged particles and photons at different collision energies and centralities are discussed. We also discuss the hypothesis of limiting fragmentation and expansion dynamics using the Landau hydrodynamics and the underlying physics. Meanwhile, we present the estimation of initial energy density multiplied with formation time as a function of different collision energies and centralities. In the end, the transverse energy per charged particle in connection with the chemical freeze-out criteria is discussed. We invoke various models and phenomenological arguments to interpret and characterize the fireball created in heavy-ion collisions. This review overall provides a scope to understand the heavy-ion collision data and a possible formation of a deconfined phase of partons via the global observables like charged particles, photons, and the transverse energy measurement.

  5. Asymptotic analysis of an ion extraction model

    International Nuclear Information System (INIS)

    Ben Abdallah, N.; Mas-Gallic, S.; Raviart, P.A.

    1993-01-01

    A simple model for ion extraction from a plasma is analyzed. The order of magnitude of the plasma parameters leads to a singular perturbation problem for a semilinear elliptic equation. We first prove existence of solutions for the perturbed problem and uniqueness under certain conditions. Then we prove the convergence of these solutions, when the parameters go to zero, towards the solution of a Child-Langmuir problem

  6. Ionic Liquids as Extraction Media for Metal Ions

    Science.gov (United States)

    Hirayama, Naoki

    In solvent extraction separation of metal ions, recently, many researchers have investigated possible use of hydrophobic ionic liquids as extraction media instead of organic solvents. Ionic liquids are salts of liquid state around room temperature and can act not only as solvents but also as ion-exchangers. Therefore, the extraction mechanism of metal ions into ionic liquids is complicated. This review presents current overview and perspective on evaluation of nature of hydrophobic ionic liquids as extraction media for metal ions.

  7. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Delferriere, O.; Gobin, R.; Harrault, F.; Nyckees, S.; Sauce, Y.; Tuske, O. [Commissariat a l' Energie Atomique, CEA/Saclay, DSM/IRFU, 91191 Gif/Yvette (France)

    2012-02-15

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  8. Calculation Of Extraction Optics For Ion System With Plazma Emitter

    CERN Document Server

    Frolov, B A

    2004-01-01

    The 2-D code for simulating of ion optics system of positive ion extraction from a plasma source is described. Example calculation of 100 kV optics for the extraction ion IHEP gun is presented. The trajectories of particles and emittance plots are resulted. The aberrations influ-ence strongly on ion optics for considered geometry.

  9. Transverse energy and charged particle production in heavy-ion collisions: from RHIC to LHC

    International Nuclear Information System (INIS)

    Sahoo, Raghunath; Mishra, Aditya Nath

    2014-01-01

    We study the charged particle and transverse energy production mechanism from AGS, SPS, Relativistic Heavy-Ion Collider (RHIC) to Large Hadron Collider (LHC) energies in the framework of nucleon and quark participants. At RHIC and LHC energies, the number of nucleons-normalized charged particle and transverse energy density in pseudorapidity, which shows a monotonic rise with centrality, turns out to be an almost centrality independent scaling behavior when normalized to the number of participant quarks. A universal function which is a combination of logarithmic and power-law, describes well the charged particle and transverse energy production both at nucleon and quark participant level for the whole range of collision energies. Energy dependent production mechanisms are discussed both for nucleonic and partonic level. Predictions are made for the pseudorapidity densities of transverse energy, charged particle multiplicity and their ratio (the barometric observable, [dE T /dη]/[dN ch /dη] ≡ E T /N ch ) at mid-rapidity for Pb + Pb collisions at √s NN = 5.5 TeV. A comparison with models based on gluon saturation and statistical hadron gas is made for the energy dependence of E T /N ch . (author)

  10. Design and fabrication of a Transverse Field Focussing (TFF) 180 keV negative ion accelerator

    International Nuclear Information System (INIS)

    Matuk, C.A.; Anderson, O.A.; Owren, H.M.; Paterson, J.A.; Purgalis, P.

    1985-11-01

    The 180 keV Transverse Field Focussing (TFF) negative ion accelerator described is the final component of a negative ion based neutral beam acceleration system which is being developed as proof-of-principle demonstration of a radiation hardened neutral beamline. The 180 keV beamline consists of: a surface conversion negative ion source, a 80 keV pre-accelerator, a TFF pumping, matching, and transport section, and the 180 keV TFF accelerator presented. This beamline is expected to provide 1 A of H - at 180 keV. In the design of the accelerator, particular importance was given to the rigidity of the accelerator electrode mounting structures and to the electrical isolation of the electrodes along with their related cooling lines. An optical alignment scheme was developed to assemble and to insure precision alignment of the electrodes

  11. Dependence of J/ψ suppression in heavy ion collisions on total transverse energy, nucleon numbers and J/ψ transverse momentum

    International Nuclear Information System (INIS)

    Ftacnik, J.; Lichard, P.

    1989-01-01

    We present a set of semiquantitative predictions for the behaviour of J/ψ suppression in heavy ion collisions as a function of the total transverse energy, nucleon numbers of colliding ions and the J/ψ transverse momentum. These predictions are based on the assumption that all of J/ψ suppression is due to J/ψ and χ disintegrations in collisions with hadrons in a dense hadronic gas formed in the heavy ion collisions. The hydrodynamic evolution of the hadron gas is taken into account. The onset of the quark-gluon plasma formation should manifest itself by clear qualitative deviations from J/ψ suppression calculated in this way, in particular as thresholds or kinks in the E T -dependence, or as a threshold for J/ψ suppression as a function of the atomic number of the target, expected at Cu or below. (orig.)

  12. Transverse ion energization and low-frequency plasma waves in the mid-altitude auroral zone: A case study

    International Nuclear Information System (INIS)

    Peterson, W.K.; Shelley, E.G.; Boardsen, S.A.; Gurnett, D.A.; Ledley, B.G.; Sugiura, M.; Moore, T.E.; Waite, J.H.

    1988-01-01

    The transport of ions from the ionosphere to the magnetosphere requires that ions acquire significant energy in directions both transverse and parallel to the magnetic field. There is a considerable body of experimental evidence that shows that transverse energization occurs over a wide range of altitudes on auroral field lines. Many recent analytical and simulation studies have addressed the microphysics involved in transverse ion energization. There are, however, remarkably few published high-resolution plasma and plasma wave observations obtained in the mid-altitude auroral region available to compare with the analytical and simulation studies. Several hundred hours of high-resolution plasma data obtained from the Dynamics Explorer 1 satellite have been surveyed. A wide variety of plasma environments that are difficult to simply characterize were found. We present here a comprehensive set of high-sensitivity, high-resolution plasma wave, ion, and magnetometer data obtained from an evening auroral zone crossing at r/R/sub E/∼3. The total density, thermal structure, and composition of the plasma in this representative interval varied rapidly, as did the character (mode) of low-frequency plasma waves observed. We did not find an unambiguous particle and wave signature of local transverse ion energization, but we did frequently find intervals where local transverse ion heating was consistent with the observations. We also found a downward flowing ion distribution that occurred simultaneously with a region of intense plasma wave emissions primarily below the lower hybrid resonance frequency. copyright American Geophysical Union 1988

  13. Re-hardening of hadron transverse mass spectra in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Ohnishi, A.; Otuka, N.; Sahu, P.K.; Isse, M.; Nara, Y.

    2001-01-01

    We analyze the spectra of pions and protons in heavy-ion collisions at relativistic energies from 2 A GeV to 65 + 65 A GeV by using a jet-implemented hadron-string cascade model. In this energy region, hadron transverse mass spectra first show softening until SPS energies, and re-hardening may emerge at RHIC energies. Since hadronic matter is expected to show only softening at higher energy densities, this re-hardening of spectra can be interpreted as a good signature of the quark-gluon plasma formation. (author)

  14. Transverse beam splitting made operational: Key features of the multiturn extraction at the CERN Proton Synchrotron

    Directory of Open Access Journals (Sweden)

    A. Huschauer

    2017-06-01

    Full Text Available Following a successful commissioning period, the multiturn extraction (MTE at the CERN Proton Synchrotron (PS has been applied for the fixed-target physics programme at the Super Proton Synchrotron (SPS since September 2015. This exceptional extraction technique was proposed to replace the long-serving continuous transfer (CT extraction, which has the drawback of inducing high activation in the ring. MTE exploits the principles of nonlinear beam dynamics to perform loss-free beam splitting in the horizontal phase space. Over multiple turns, the resulting beamlets are then transferred to the downstream accelerator. The operational deployment of MTE was rendered possible by the full understanding and mitigation of different hardware limitations and by redesigning the extraction trajectories and nonlinear optics, which was required due to the installation of a dummy septum to reduce the activation of the magnetic extraction septum. This paper focuses on these key features including the use of the transverse damper and the septum shadowing, which allowed a transition from the MTE study to a mature operational extraction scheme.

  15. Transverse Momentum Dependent Parton Distribution/Fragmentation Functions at an Electron-Ion Collider

    International Nuclear Information System (INIS)

    Anselmino, M.; Avakian, H.; Boer, D.; Bradamante, F.; Burkardt, M.; Chen, J.P.; Cisbani, E.; Contalbrigo, M.; Crabb, D.; Dutta, D.; Gamberg, L.; Gao, H.; Hasch, D.; Huang, J.; Huang, M.; Kang, Z.; Keppel, C.; Laskaris, G.; Liang, Z.-T.; Liu, M.X.; Makins, N.; Mckeown, R.D.; Metz, A.; Meziani, Z.-E.; Musch, B.; Peng, J.-C.; Prokudin, A.; Qian, X.; Qiang, Y.; Qiu, J.W.; Rossi, P.; Schweitzer, P.; Soffer, J.; Sulkosky, V.; Wang, Y.; Xiao, B.; Ye, Q.; Ye, Q.-J.; Yuan, F.; Zhan, X.; Zhang, Y.; Zheng, W.; Zhou, J.

    2011-01-01

    We present a summary of a recent workshop held at Duke University on Partonic Transverse Momentum in Hadrons: Quark Spin-Orbit Correlations and Quark-Gluon Interactions. The transverse momentum dependent parton distribution functions (TMDs), parton-to-hadron fragmentation functions, and multi-parton correlation functions, were discussed extensively at the Duke workshop. In this paper, we summarize first the theoretical issues concerning the study of partonic structure of hadrons at a future electron-ion collider (EIC) with emphasis on the TMDs. We then present simulation results on experimental studies of TMDs through measurements of single spin asymmetries (SSA) from semi-inclusive deep-inelastic scattering (SIDIS) processes with an EIC, and discuss the requirement of the detector for SIDIS measurements. The dynamics of parton correlations in the nucleon is further explored via a study of SSA in D ((bar D)) production at large transverse momenta with the aim of accessing the unexplored tri-gluon correlation functions. The workshop participants identified the SSA measurements in SIDIS as a golden program to study TMDs in both the sea and valence quark regions and to study the role of gluons, with the Sivers asymmetry measurements as examples. Such measurements will lead to major advancement in our understanding of TMDs in the valence quark region, and more importantly also allow for the investigation of TMDs in the sea quark region along with a study of their evolution.

  16. Transverse energy per charged particle in heavy-ion collisions: Role of collective flow

    Science.gov (United States)

    Kumar Tiwari, Swatantra; Sahoo, Raghunath

    2018-03-01

    The ratio of (pseudo)rapidity density of transverse energy and the (pseudo)rapidity density of charged particles, which is a measure of the mean transverse energy per particle, is an important observable in high energy heavy-ion collisions. This ratio reveals information about the mechanism of particle production and the freeze-out criteria. Its collision energy and centrality dependence is almost similar to the chemical freeze-out temperature until top Relativistic Heavy-Ion Collider (RHIC) energy. The Large Hadron Collider (LHC) measurement at √{s_{NN}} = 2.76 TeV brings up new challenges towards understanding the phenomena like gluon saturation and role of collective flow, etc. being prevalent at high energies, which could contribute to the above observable. Statistical Hadron Gas Model (SHGM) with a static fireball approximation has been successful in describing both the centrality and energy dependence until top RHIC energies. However, the SHGM predictions for higher energies lie well below the LHC data. In order to understand this, we have incorporated collective flow in an excluded-volume SHGM (EV-SHGM). Our studies suggest that the collective flow plays an important role in describing E T/ N ch and it could be one of the possible parameters to explain the rise observed in E T/ N ch from RHIC to LHC energies. Predictions are made for E T/ N ch , participant pair normalized-transverse energy per unit rapidity and the Bjorken energy density for Pb+Pb collisions at √{s_{NN}} = 5.02 TeV at the Large Hadron Collider.

  17. Modeling transverse heating and outflow of ionospheric ions from the dayside cusp/cleft. 2 Applications

    Directory of Open Access Journals (Sweden)

    M. Bouhram

    2003-08-01

    Full Text Available In this paper, we consider major ion energization mechanisms in the dayside cusp/cleft region. This includes transverse ion heating by ion cyclotron resonance (ICR, ion energization through structures of field-aligned electric potential drops, and transverse heating by lower hybrid (LH waves. First, we present and discuss three typical cusp/cleft crossings associated with one of the first two mechanisms mentioned above. Then, we develop a procedure for finding the altitude dependence of ICR heating for any data set in the high-altitude cusp/cleft under the absence of field-aligned potential drops. This has been accomplished using a large set of numerical simulations from a two-dimensional, steady-state, Monte Carlo, trajectory-based code, as discussed in detail in the first companion paper (Bouhram et al., 2003. The procedure is applied and tested successfully for the first two events, by using patterns of ion moments along the satellite track as constraints. Then, we present a statistical study that uses 25 cusp/cleft crossings associated with steady IMF conditions, where ICR heating is expected to occur alone. It is pointed out that the ICR heating increases gradually versus geocentric distance as s 3.3 ± 1.8 . The inferred values of the wave power and the spectral index associated with the component responsible for ICR heating are lower than those characterizing the broad-band, extremely low-frequency (BBELF turbulence usually observed in the cusp/cleft. This strengthens the idea that more than one wave-mode is contained in the BBELF turbulence, and only a small fraction of the observed turbulence is responsible for ICR heating. Then, we study the occurrence versus magnetic local time (MLT of field-aligned potential drops. According to previous statistical studies, such structures are not common in the cusp and tend to be associated with the cleft region. We also discuss the effects of LH heating in the cusp on the observed ion distributions

  18. Transverse ion energization and low-frequency plasma waves in the mid-altitude auroral zone - A case study

    Science.gov (United States)

    Peterson, W. K.; Shelley, E. G.; Boardsen, S. A.; Gurnett, D. A.; Ledley, B. G.; Sugiura, M.; Moore, T. E.

    1988-01-01

    Evidence of transverse ion energization at altitudes of several earth radii in the auroral zone was reexamined using several hundred hours of high-sensitivity and high-resolution plasma data obtained by the Dynamics Explorer 1 satellite. The data on particle environment encountered at midaltitudes in the auroral zone disclosed rapid variations in the values of total density, thermal structure, and composition of the plasma in the interval measured; the modes of low-frequency plasma waves also varied rapidly. It was not possible to unambiguously identify in these data particle and wave signature of local transverse ion energization; however, many intervals were found where local transverse ion heating was consistent with the observations.

  19. Ionic liquids used in extraction and separation of metal ions

    International Nuclear Information System (INIS)

    Shen Xinghai; Xu Chao; Liu Xinqi; Chu Taiwei

    2006-01-01

    Ionic liquids as green solvents now have become a research hotspot in the field of separation of metal ions by solvent extraction. Experimental results of extraction of various metal ions with ionic liquids as solvents, including that of alkali metals, alkaline earths, transition metals rare earths and actinides are introduced. The extraction of uranium, plutonium and fission products that are involved in spent nuclear fuel reprocessing is also reviewed. The possible extraction mechanisms are discussed. Finally, the prospect of replacement of volatile and/or toxic organic solvents with environmentally benign ionic liquids for solvent extraction and the potency of applications of ionic liquids in solvent extraction are also commented. (authors)

  20. Ion extraction capabilities of closely spaced grids

    Science.gov (United States)

    Rovang, D. C.; Wilbur, P. J.

    1982-01-01

    The ion extraction capabilities of accelerator systems with small screen hole diameters (less than 2.0 mm) are investigated at net-accelerating voltages of 100, 300, and 500 V. Results show that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 1.0 mm, but impingement-limited performance was found to be dependent on the grid separation distance, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained using small hole diameters and closely spaced grids indicate a new mode of grid operation where high current density operation can be achieved with a specified net acceleration voltage by operating the grids at a high rather than low net-to-total acceleration voltage. Beam current densities as high as 25 mA/sq cm were obtained using grids with 1.0 mm diameter holes operating at a net accelerating voltage of 500 V.

  1. Smooth transverse and longitudinal focusing in high-intensity ion linacs

    International Nuclear Information System (INIS)

    Billen, J.H.; Takeda, Harunori; Young, L.M.

    1996-01-01

    We examine ion linac designs that start with a high energy radio- frequency quadrupole (RFQ) followed by either a drift-tube linac (DTL) or a coupled-cavity drift-tube linac (CCDTL). For high energies a conventional CCL follows the CCDTL. High RFQ output energy allows tailoring the transverse and longitudinal focusing strengths to match into the following structure. When the RFQ beam enters a higher frequency structure, the DTL or CCDTL starts with a low accelerating gradient and large negative synchronous phase. The gradient and phase both ramp up gradually to higher values. Other changes later in the machine are also gradual. Beam dynamics simulations show that these linacs require no separate matching sections. Applications include a cw 100 mA H + beam from a 350-MHz, 6.7 MeV RFQ injecting a 700 MHz CCDTL and CCL; a 7% duty 28 mA H - beam from a 402.5 MHz RFQ and DTL injecting 805 MHz structures; a cw 135 mA D + beam produced by a 175 MHz, 8 MeV RFQ and DTL; and a 2.4% duty, 80 mA H + beam using a 433 MHz 10 MeV RFQ and a 1300 MHz CCDTL. The machines take advantage of the considerable flexibility of the CCDTL. Designs can use a variety of different transverse focusing lattices. Use of two coupling cavity orientations permits a constant period even when the number of drift tubes per cavity changes along the linac

  2. Ion extraction from positively biased laser-ablation plasma

    International Nuclear Information System (INIS)

    Isono, Fumika; Nakajima, Mitsuo; Hasegawa, Jun; Horioka, Kazuhiko

    2016-01-01

    Ions were extracted through a grounded grid from a positively biased laser-ablation plasma and the behaviors were investigated. Since the plasma was positively biased against the grounded wall, we could extract the ions without insulated gap. We confirmed formation of a virtual anode when we increased the distance between the grid and the ion collector. Results also indicated that when the ion flux from the ablation plasma exceeded a critical value, the current was strongly suppressed to the space charge limited level due to the formation of virtual anode.

  3. Transverse acceptance calculation for continuous ion beam injection into the electron beam ion trap charge breeder of the ReA post-accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kittimanapun, K., E-mail: kritsadak@slri.or.th [National Superconducting Cyclotron Laboratory (NSCL), Michigan State University (MSU), 640 S. Shaw Lane, East Lansing, Michigan 48824 (United States); Synchrotron Light Research Institute (SLRI), 111 University Avenue, Muang District, Nakhon Ratchasima, 30000 (Thailand); Baumann, T.M.; Lapierre, A.; Schwarz, S. [National Superconducting Cyclotron Laboratory (NSCL), Michigan State University (MSU), 640 S. Shaw Lane, East Lansing, Michigan 48824 (United States); Bollen, G. [National Superconducting Cyclotron Laboratory (NSCL), Michigan State University (MSU), 640 S. Shaw Lane, East Lansing, Michigan 48824 (United States); Facility for Rare Isotope Beams (FRIB), Michigan State University, 640 S. Shaw Lane, East Lansing, Michigan 48824 (United States)

    2015-11-11

    The ReA post-accelerator at the National Superconducting Cyclotron Laboratory (NSCL) employs an electron beam ion trap (EBIT) as a charge breeder. A Monte-Carlo simulation code was developed to calculate the transverse acceptance phase space of the EBIT for continuously injected ion beams and to determine the capture efficiency in dependence of the transverse beam emittance. For this purpose, the code records the position and time of changes in charge state of injected ions, leading either to capture or loss of ions. To benchmark and validate the code, calculated capture efficiencies were compared with results from a geometrical model and measurements. The results of the code agree with the experimental findings within a few 10%. The code predicts a maximum total capture efficiency of 50% for EBIT parameters readily achievable and an efficiency of up to 80% for an electron beam current density of 1900 A/cm{sup 2}.

  4. Selective and Efficient Solvent Extraction of Copper(II Ions from Chloride Solutions by Oxime Extractants

    Directory of Open Access Journals (Sweden)

    Zahra Kaboli Tanha

    2016-06-01

    Full Text Available Oxime extractants 3-tert-butyl-2-hydroxy-5-methyl benzaldehyde oxime (HL1 and 3-tert-butyl-2-hydroxy-5-methoxy benzaldehyde oxime (HL2 were synthesized and characterized by conventional spectroscopic methods. Suitable lipophilic nature of the prepared extractants allowed examining the ability of these molecules for extraction-separation of copper from its mixture with normally associated metal ions by performing competitive extraction experiments of Cu(II, Co(II, Ni(II, Zn(II, Cd(II and Pb(II ions from chloride solutions. Both ligands transfer selectively the copper ions into dichloromethane by a cation exchange mechanism. Conventional log-log analysis and isotherm curves showed that Cu(II ions are extracted as the complexes with 1:2 metal to ligand ratio by both extractants. Verification of the effect of the organic diluent used in the extraction of copper ions by HL1 and HL2 demonstrated that the extraction efficiency varies as: dichloromethane ~ dichloroethane > toluene > xylene > ethylacetate. Time dependency investigation of the extraction processes revealed that the kinetics of the extraction of copper by HL2 is more rapid than that of HL1. The application of the ligands for extraction-separation of copper ions from leach solutions of cobalt and nickel-cadmium filter-cakes of a zinc production plants was evaluated.

  5. Poisoning of liquid membrane carriers in extraction of metal ions

    International Nuclear Information System (INIS)

    Wang, Yuchun; Wang, Dexian

    1992-01-01

    As means of effective separation and preconcentration, emulsion liquid membranes (ELMs) have found application in many fields including biochemical separation, wastewater treatment, hydrometallurgy, and preconcentration in analytical chemistry. In the extraction of desired metal (scandium, mixed rare earths) ions using chelating extractants (TTA, HDEHP) as liquid membrane carriers, the carriers will become poisoned owing to the presence of even minute quantity of certain high ionic potential ions in the feed solution. The reason for the poisoning of carriers is that those ions have so much greater affinity than the desired ions for the membrane carrier that the ion-carrier coordination compound cannot be stripped at the interior interface of the membrane and gradually no more free carrier transports any metal ions across the membrane. The calculated results are in agreement with the experiments, and methods to avoid the poisoning are given in the paper

  6. Effect of Coulomb collision on the negative ion extraction mechanism in negative ion sources.

    Science.gov (United States)

    Goto, I; Miyamoto, K; Nishioka, S; Mattei, S; Lettry, J; Abe, S; Hatayama, A

    2016-02-01

    To improve the H(-) ion beam optics, it is necessary to understand the energy relaxation process of surface produced H(-) ions in the extraction region of Cs seeded H(-) ion sources. Coulomb collisions of charged particles have been introduced to the 2D3V-PIC (two dimension in real space and three dimension in velocity space particle-in-cell) model for the H(-) extraction by using the binary collision model. Due to Coulomb collision, the lower energy part of the ion energy distribution function of H(-) ions has been greatly increased. The mean kinetic energy of the surface produced H(-) ions has been reduced to 0.65 eV from 1.5 eV. It has been suggested that the beam optics of the extracted H(-) ion beam is strongly affected by the energy relaxation process due to Coulomb collision.

  7. Scattering extraction of ions at CRYRING for SEU testing

    CERN Document Server

    Novák, D; Klamra, W; Norlin, L O; Bagge, L; Kaellberg, A; Paál, A; Rensfelt, K G; Molnár, J

    1999-01-01

    A measuring station has been built at the CRYRING heavy ion accelerator to test the Single Event Upset (SEU) phenomena in working Static RAM circuits. The setup extracts the beam using Rutherford scattering and the ions are monitored with a BaF sub 2 scintillator. SEU measurements have been performed for standard bulk CMOS memory circuits.

  8. Selective Liquid-Liquid Extraction of Lead Ions Using Newly Synthesized Extractant 2-(Dibutylcarbamoylbenzoic Acid

    Directory of Open Access Journals (Sweden)

    Hossein Soltani

    2015-12-01

    Full Text Available A new carboxylic acid extractant, named 2-(dibutylcarbamoylbenzoic acid, is prepared and its potential for selective solvent extraction and recovery of lead ions from industrial samples was investigated. The slope analysis indicated that the lead ions are extracted by formation of 1:2 metal to ligand complexes. The effect of the parameters influencing the extraction efficiency including kind of the organic diluent, extractant concentration, type of the salt used for ionic strength adjustment, contact time and temperature was evaluated and discussed. Under optimized conditions (aqueous phase: 5 ml, initial lead concentration 1 × 10-4 M, pH 4, sodium chloride 0.1 M; organic phase: 5 ml dichloromethane, ligand concentration 0.05 M, a quantitative (75.2 ± 0.8% and highly selective extraction of lead ions in the presence of zinc, nickel, cobalt and cadmium ions (each 1 × 10-4 M was achieved, after 20 min. magnetically stirring of the phases, at      25 °C. The extracted lead ions were stripped from the organic phase by diluted nitric acid (0.1 M solution. The proposed method was successfully applied for separation of lead from industrial samples. The study of the effect of temperature allowed evaluating the thermodynamic parameters of the extraction process of lead ions by the studied extractant into dichloromethane.

  9. Negative hydrogen ion beam extraction from an AC heated cathode driven Bernas-type ion source

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Y.; Miyamoto, N.; Kasuya, T.; Wada, M.

    2015-04-08

    A plasma grid structure was installed to a Bernas-type ion source used for ion implantation equipment. A negative hydrogen (H{sup −}) ion beam was extracted by an AC driven ion source by adjusting the bias to the plasma grid. The extracted electron current was reduced by positively biasing the plasma grid, while an optimum plasma grid bias voltage for negative ion beam extraction was found to be positive 3 V with respect to the arc chamber. Source operations with AC cathode heating show extraction characteristics almost identical to that with DC cathode heating, except a minute increase in H{sup −} current at higher frequency of cathode heating current.

  10. Analytical studies of plasma extraction electrodes and ion beam formation

    International Nuclear Information System (INIS)

    Hassan, A.; Elsaftawy, A.; Zakhary, S. G.

    2007-01-01

    In this work a theoretical and computational study on the space charge dominated beams extracted from a plasma ion source through a spherical and planer electrode is simulated and optimized. The influence of some electrode parameters: axial position, electrode diameter, material and shape; on ion current extracted from a plasma source; were investigated and compared. The optimum values and conditions of the curvature of the plasma boundary, angular divergence, perveance, and the extraction gap were optimized to extract a high quality beams. It has shown that for a planar electrode system there is usually a minimum for optimum perveance versus angular divergence at about ? 0.6 for corresponding aspect ratios. This was assured by experimental data. The appropriate spherical electrode system focus the beam to a minimum value located at a distance equal to the focal length of the spherical extraction electrode.

  11. Light ion source studies with a magnetically insulated extraction diode

    International Nuclear Information System (INIS)

    Struckman, C.K.

    1992-01-01

    Light ion sources are currently being studied to assess their ability to drive an inertial confinement fusion reactor. The author has produced a high purity, 1MV, 300A/cm 2 lithium beam using a 200cm 2 extraction geometry, magnetically insulated ion diode. The lithium source was an AC glow discharge cleaned, LiF/Al film active anode. The active anode plasma was formed after 50KA of current was shunted through the anode film for 20ns. The stoichiometry of the resulting ion beam was 65% Li + , 20% Al +2 , and 15% H + . Without the glow discharge cleaning, the ion beam was over 55% hydrogen and only 20% Li + . At the time of the diode's design, extraction diodes were producing poor ion beams: their current efficiency was only 60-70%, and their extracted ion current was radially nonuniform. This diode was the first high efficiency extraction diode, and produced over 200KA of ions with 80-90% ion current efficiency. In addition, by varying the tilt of the applied magnetic field, it was possible to show that the ion current density could be made independent of radius. Since the author was unable to make a Li + beam with a passive anode, he installed an active anode that used an external current to vaporize a thin metal film on the anode surface. Poor beam purity was the most serious problem with active anodes. In order to remove impurities, especially the hydrogen contamination, the author cleaned the anodes with a glow discharge. Al film anodes were cleaned with a 110mA, 33W DC glow discharge, and the LiF/Al film anodes were cleaned with an equivalent AC discharge. The results obtained and a model for the mechanism behind the cleaning process are throughly discussed

  12. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems

    International Nuclear Information System (INIS)

    Cordero Lopez, F.

    1961-01-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  13. Direct extraction of negative lithium ions from a lithium plasma

    International Nuclear Information System (INIS)

    Wada, M.; Tsuda, H.; Sasao, M.

    1990-01-01

    Negative lithium ions (Li - ) were directly extracted from a lithium plasma in a multiline cusp plasma container. A pair of permanent magnets mounted near the extractor electrode created the filter magnetic field that separated the extraction region plasma from the main discharge plasma. The plasma electrode facing the extraction region plasma was biased with respect to the other parts of the chamber wall, which acted as discharge anodes. The larger filter magnetic field resulted larger Li - current. When the bias to the plasma electrode was several volts positive against the anode potential, extracted Li - current took the maximum for a fixed strength of the filter field. These dependences of Li - upon the filter magnetic field and the plasma electrode bias are similar to the ones of negative hydrogen ions

  14. The role of space charge compensation for ion beam extraction and ion beam transport (invited)

    International Nuclear Information System (INIS)

    Spädtke, Peter

    2014-01-01

    Depending on the specific type of ion source, the ion beam is extracted either from an electrode surface or from a plasma. There is always an interface between the (almost) space charge compensated ion source plasma, and the extraction region in which the full space charge is influencing the ion beam itself. After extraction, the ion beam is to be transported towards an accelerating structure in most cases. For lower intensities, this transport can be done without space charge compensation. However, if space charge is not negligible, the positive charge of the ion beam will attract electrons, which will compensate the space charge, at least partially. The final degree of Space Charge Compensation (SCC) will depend on different properties, like the ratio of generation rate of secondary particles and their loss rate, or the fact whether the ion beam is pulsed or continuous. In sections of the beam line, where the ion beam is drifting, a pure electrostatic plasma will develop, whereas in magnetic elements, these space charge compensating electrons become magnetized. The transport section will provide a series of different plasma conditions with different properties. Different measurement tools to investigate the degree of space charge compensation will be described, as well as computational methods for the simulation of ion beams with partial space charge compensation

  15. Study of the negative ion extraction mechanism from a double-ion plasma in negative ion sources

    International Nuclear Information System (INIS)

    Goto, I.; Nishioka, S.; Hatayama, A.; Miyamoto, K.

    2015-01-01

    We have developed a 2D3V-PIC model of the extraction region, aiming to clarify the basic extraction mechanism of H − ions from the double-ion plasma in H − negative ion sources. The result shows the same tendency of the H − ion density n H − as that observed in the experiments, i.e.,n H − in the upstream region away from the plasma meniscus (H − emitting surface) has been reduced by applying the extraction voltage. At the same time, relatively slow temporal oscillation of the electric potential compared with the electron plasma frequency has been observed in the extraction region. Results of the systematic study using a 1D3V-PIC model with the uniform magnetic field confirm the result that the electrostatic oscillation is identified to be lower hybrid wave. The effect of this oscillation on the H − transport will be studied in the future

  16. Quantitative Analysis of Tenofovir by Titrimetric, Extractive Ion-pair ...

    African Journals Online (AJOL)

    Methods: Tenofovir disoproxil forms a complex of 1:1 molar ratio with fumaric acid that was employed in its aqueous titration with sodium hydroxide. Non-aqueous titration was also employed for its determination. Extractive ion-pair spectrophotometric technique using methyl orange was similarly employed to evaluate ...

  17. Multiaperture ion beam extraction from gas-dynamic electron cyclotron resonance source of multicharged ions

    International Nuclear Information System (INIS)

    Sidorov, A.; Dorf, M.; Zorin, V.; Bokhanov, A.; Izotov, I.; Razin, S.; Skalyga, V.; Rossbach, J.; Spaedtke, P.; Balabaev, A.

    2008-01-01

    Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be ∼70 π mm mrad, and the total extracted beam current obtained at 14 kV extraction voltage was ∼25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data

  18. A Study on the Ion Beam Extraction using Duo-PiGatron Ion source for Vertical Type Ion Beam Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sok; Lee, Chan young; Lee, Jae Sang [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In Korea Multipurpose Accelerator Complex (KOMAC), we have started ion beam service in the new beam utilization building since March this year. For various ion beam irradiation services, we are developed implanters such as metal (150keV/1mA), gaseous (200keV/5mA) and high current ion beam facility (20keV/150mA). One of the new one is a vertical type ion beam facility without acceleration tube (60keV/20mA) which is easy to install the sample. After the installation is complete, it is where you are studying the optimal ion beam extraction process. Detailed experimental results will be presented. Vertical Type Ion Beam Facility without acceleration tube of 60keV 20mA class was installed. We successfully extracted 60keV 20mA using Duo- PiGatron Ion source for Vertical Type Ion Beam Facility. Use the BPM and Faraday-cup, is being studied the optimum conditions of ion beam extraction.

  19. Simulation study on ion extraction from electron cyclotron resonance ion sources

    Science.gov (United States)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1994-04-01

    In order to study beam optics of NIRS-ECR ion source used in the HIMAC project, the EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1D and 2D sheath theories are used, respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source are presented in this paper, exhibiting an agreement with the experiment results.

  20. Extraction of metal ions by neutral β-diphosphoramides

    International Nuclear Information System (INIS)

    Madic, C.

    1990-01-01

    The extracting ability of β-diphosphoramides of the type R-N[P(O)(NMe 2 ) 2 ] 2 with R=-CH 3 (NIPA), -C 12 H 25 (ODIPA), or -C 16 H 33 (OHDIPA) for metal ions such as lanthanides, uranyl, and the transuranium elements Am(III) and Pu(IV) has been studied. Extraction yields depend on the nature of the ligand, the organic diluent (nitromethane, kerosene, tert-butylbenzene), the concentration of nitric acid in the aqueous phase, and the ligand-to-metal ratio, Q. The results show that the bidentate phosphoramides are very efficient extractants for all of the metals studied, even at low ratios Q. The presence of nitric acid generally enhances the extraction yields. On the other hand, selectivity is rather poor with these ligands. A particular effort has been made to determine the nature of extracted species by NMR spectroscopy

  1. Ion-pair extraction of [3]histobadine from biological fluids

    International Nuclear Information System (INIS)

    Scasnar, V.

    1997-01-01

    A simple and specific radiometric assay was developed for determination of stobadine, a cardio protective drug, in the serum of experimental animals. It is based on a single extraction step of the radioactively labeled drug from serum into the benzene solution of dicarbolide of cobalt followed by the quantitation of the extracted radioactivity by using liquid scintillation counting. The extraction mechanism involves the ion-pair formation between the protonized molecule of stobadine and the hydrophobic, negatively charged molecule of dicarbollide of cobalt. The extraction of yield of stobadine from 1 ml of serum was 95% in the concentration range from 1 to 6000 ng/ml. The co extraction of metabolites was less than 5%. The assay was applied to determination of stobadine in serum of dogs and the data obtained were in good agreement with those obtained by high performance liquid chromatography. (author)

  2. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  3. First observations of intensity-dependent effects for transversely split beams during multiturn extraction studies at the CERN Proton Synchrotron

    Directory of Open Access Journals (Sweden)

    Simone Gilardoni

    2013-05-01

    Full Text Available During the commissioning of the CERN Proton Synchrotron multiturn extraction, tests with different beam intensities were performed in order to probe the behavior of resonance crossing in the presence of possible space charge effects. The initial beam intensity before transverse splitting was varied and the properties of the five beamlets obtained by crossing the fourth-order horizontal resonance were studied. A clear dependence of the beamlets’ parameters on the total beam intensity was found, which is the first direct observation of intensity-dependent effects for such a peculiar beam type. The experimental results are presented and discussed in detail in this paper.

  4. Metal negative ion beam extraction from a radio frequency ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, S.; Yamada, N.; Kasuya, T.; Romero, C. F. P.; Wada, M.

    2015-04-08

    A metal ion source of magnetron magnetic field geometry has been designed and operated with a Cu hollow target. Radio frequency power at 13.56 MHz is directly supplied to the hollow target to maintain plasma discharge and induce self-bias to the target for sputtering. The extraction of positive and negative Cu ion beams have been tested. The ion beam current ratio of Cu{sup +} to Ar{sup +} has reached up to 140% when Ar was used as the discharge support gas. Cu{sup −} ion beam was observed at 50 W RF discharge power and at a higher Ar gas pressure in the ion source. Improvement of poor RF power matching and suppression of electron current is indispensable for a stable Cu{sup −} ion beam production from the source.

  5. Effect of Coulomb collision on the negative ion extraction mechanism in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I., E-mail: goto@ppl.appi.keio.ac.jp; Nishioka, S.; Abe, S.; Hatayama, A. [Graduate School of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Mattei, S.; Lettry, J. [CERN, 1211 Geneva 23 (Switzerland)

    2016-02-15

    To improve the H{sup −} ion beam optics, it is necessary to understand the energy relaxation process of surface produced H{sup −} ions in the extraction region of Cs seeded H{sup −} ion sources. Coulomb collisions of charged particles have been introduced to the 2D3V-PIC (two dimension in real space and three dimension in velocity space particle-in-cell) model for the H{sup −} extraction by using the binary collision model. Due to Coulomb collision, the lower energy part of the ion energy distribution function of H{sup −} ions has been greatly increased. The mean kinetic energy of the surface produced H{sup −} ions has been reduced to 0.65 eV from 1.5 eV. It has been suggested that the beam optics of the extracted H{sup −} ion beam is strongly affected by the energy relaxation process due to Coulomb collision.

  6. Massive parallel 3D PIC simulation of negative ion extraction

    Science.gov (United States)

    Revel, Adrien; Mochalskyy, Serhiy; Montellano, Ivar Mauricio; Wünderlich, Dirk; Fantz, Ursel; Minea, Tiberiu

    2017-09-01

    The 3D PIC-MCC code ONIX is dedicated to modeling Negative hydrogen/deuterium Ion (NI) extraction and co-extraction of electrons from radio-frequency driven, low pressure plasma sources. It provides valuable insight on the complex phenomena involved in the extraction process. In previous calculations, a mesh size larger than the Debye length was used, implying numerical electron heating. Important steps have been achieved in terms of computation performance and parallelization efficiency allowing successful massive parallel calculations (4096 cores), imperative to resolve the Debye length. In addition, the numerical algorithms have been improved in terms of grid treatment, i.e., the electric field near the complex geometry boundaries (plasma grid) is calculated more accurately. The revised model preserves the full 3D treatment, but can take advantage of a highly refined mesh. ONIX was used to investigate the role of the mesh size, the re-injection scheme for lost particles (extracted or wall absorbed), and the electron thermalization process on the calculated extracted current and plasma characteristics. It is demonstrated that all numerical schemes give the same NI current distribution for extracted ions. Concerning the electrons, the pair-injection technique is found well-adapted to simulate the sheath in front of the plasma grid.

  7. Sheath formation and extraction of ions from a constricted R.F ion source

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Salam, F W; Helal, A G; El-Khabeary, H; El-Merai, N T [Accelerators Dept., Nuclear Research Center, Atomic Energy Authority, Cairo, (Egypt)

    1997-12-31

    The present work investigates the plasma characteristics in a constricted R. F. ion source. The extraction of ions from the plasma boundary and sheath formation were studied. The ion source physical parameters are discussed in order to understand the physical processes occurring within the discharge region up to the extraction system. Electron temperature and density were determined using Langmuir probe. The probe current-voltage characteristics were measured for different extraction voltages (ext.) = 0,500,1000, and 1250 volt at various constant R.F. powers. The effect of R.F. power on electron temperature was deduced for a beam = plasma discharge. This revealed that for a quasi-neutral (plasma) region the electron temperature increased linearly with the R.F. Power which leads to substantial electron heating and efficient electron energy transport in this region. Applying extraction voltage, the electron temperature drops as the ionization rate increases. The sheath thickness was obtained at constant extraction voltages. The curves show that if the ion current density increased, the sheath thickness decreased while it increases by increasing extraction voltage, and it is negligible in the plasma region. 13 figs.

  8. A linear ion optics model for extraction from a plasma ion source

    International Nuclear Information System (INIS)

    Dietrich, J.

    1987-01-01

    A linear ion optics model for ion extraction from a plasma ion source is presented, based on the paraxial equations which account for lens effects, space charge and finite source ion temperature. This model is applied to three- and four-electrode extraction systems with circular apertures. The results are compared with experimental data and numerical calculations in the literature. It is shown that the improved calculations of space charge effects and lens effects allow better agreement to be obtained than in earlier linear optics models. A principal result is that the model presented here describes the dependence of the optimum perveance on the aspect ratio in a manner similar to the nonlinear optics theory. (orig.)

  9. Extraction of europium (3) ions with stearic acid

    International Nuclear Information System (INIS)

    Lobanov, F.I.; Gladyshchev, V.P.; Nurtaeva, A.K.; Andreeva, N.N.

    1981-01-01

    Extraction of europium (3) in nitric acid solutions with the melts of stearic acid and its mixtures with paraffin at (80+-1) deg C is studied. The constant of stearic acid dimerization in paraffin K 2 =9.6+-0.6 and the constant of stearic acid distribution in the paraffin-water system Ksub(D,HA)=(1.06+-0.07)x10sub(3) are determined. The diagram of europium ion extraction at initial concentrations of metal in the aqueous phase of 10 -4 -10 -3 mol/l is suggested. The compound extracted has the EuA 3 composition with extraction constant of lg Ksub(ex)=-7.58 [ru

  10. Methods of measuring of the ion beam transversal emittance in the injection channel of the cyclotron DC-72

    CERN Document Server

    Kazarinov, N; Kalagin, I V; Kazacha, V I

    2002-01-01

    The methods of measuring of the transversal emittance of ion beams in the cyclotron DC-72 injection channel with the help of the 'pepper-pot' and gradient means are discussed in this work. Two ways for the reconstruction of the ion beam transversal emittance are proposed for the 'pepper-pot' method. The first one can be used for beams having the uniform distribution of particles in the phase space. At that the values of the Twiss matrix and the full beam emittance are reconstructed according to the measurement results with the help of the phase ellipse fitting by the least-squares method. The corresponding FORTRAN code was created. On simulation the beam emittance was reconstructed with accuracy of 5%. The second method of the beam emittance reconstruction can be used in the common case at the arbitrary particle distribution in the phase space. It is based on calculation of the mean-square parameters of the beam according to the measurement results in the plane of the 'pepper-pot' mask. The mean-square emitta...

  11. Modeling transverse heating and outflow of ionospheric ions from the dayside cusp/cleft. 1 A parametric study

    Directory of Open Access Journals (Sweden)

    M. Bouhram

    2003-08-01

    Full Text Available The transport patterns of non-thermal H + and O + field-aligned flows from the dayside cusp/cleft, associated with transverse heating by means of wave-particle interactions and in combination with the poleward motion due to the magnetospheric convection are investigated. This has been accomplished by developing a steady-state, two-dimensional, trajectory-based code. The ion heating is modelled by means of a Monte Carlo technique, via the process of ion cyclotron resonance (ICR, with the electromagnetic left-hand circular polarized component of a broad-band, extremely low-frequency (BBELF turbulence. The altitude dependence of ICR heating from 1000 km to 3 Earth radii (RE is modelled by a power law spectrum, with an index a, and a parameter w0 that is proportional to the spectral density at a referenced gyrofrequency. Because of the finite latitudinal extent of the cusp/cleft, the incorporation of the horizontal convection drift leads to a maximum residence time tD of the ions when being energized. A large set of simulations has been computed so as to study the transport patterns of the H + and O + bulk parameters as a function of tD , a, and w0. Residence time effects are significant in O + density patterns while negligible for H +. When comparing the results with analytical one-dimensional theories (Chang et al., 1986; Crew et al., 1990, we find that mean ion energies and pitch angles at the poleward edge of the heating region are slightly influenced by tD and may be used as a probe of ICR parameters ( a, w0. Conversely, poleward of the heating region, upward velocity and mean energy dispersive patterns depend mainly on tD (e.g. the magnitude of the convection drift with latitudinal profiles varying versus tD . In short, the main conclusion of the paper is that any triplet (tD , a, w0 leads to a unique transport-pattern feature of ion flows associated with a cusp/cleft ionospheric source. In a companion paper, by using high-altitude (1.5–3 RE

  12. Softening and re-hardening of hadron transverse mass spectra in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Isse, M.; Otuka, N.; Ohnishi, A.; Sahu, P.K.; Nara, Y.

    2002-01-01

    At RHIC experiments, started at 2000, the data obtained recently seem to exhibit QGP formation, but the conclusion is not drawn yet. Here, we pay out attention to the collective motion at hadronic freeze-out as an evidence of QGP formation. The transverse mass spectra may show softening to re-hardening with increasing incident energy. We compare simulated results obtained in JAM' - a hadronic cascade model - with experimental data, and discuss weather the QGP is formed or not. (author)

  13. Two-dimensional particle simulation of negative ion extraction from a volume source

    International Nuclear Information System (INIS)

    Naitou, H.; Fukumasa, O.; Sakachou, K.; Mutou, K.

    1995-01-01

    Two-dimensional electrostatic particle simulation was done to study the extraction of negative ions from a volume plasma source. The simulation model is a rectangular system which consists of an extraction grid, a plasma grid, and a grounded wall. Full dynamics of electrons, ions, and negative ions are followed. Negative ions are extracted from the plasma region to the extraction grid through a slit in the plasma grid. For the lower value of extraction grid potential, the simulation results agree with the Child-Langumuir law, where the extracted negative ion current is proportional to the three-halves power of the potential of the extraction grid. For the higher value of extraction grid potential, the space charge effect of negative ions, which enter into the beamline at the top of the concavity of the positive ion boundary, reduces the negative ion current from the prediction of the Child-Langumuir law. ((orig.))

  14. In-depth study of in-trap high-resolution mass separation by transversal ion ejection from a multi-reflection time-of-flight device.

    Science.gov (United States)

    Fischer, Paul; Knauer, Stefan; Marx, Gerrit; Schweikhard, Lutz

    2018-01-01

    The recently introduced method of ion separation by transversal ejection of unwanted species in electrostatic ion-beam traps and multi-reflection time-of-flight devices has been further studied in detail. As this separation is performed during the ion storage itself, there is no need for additional external devices such as ion gates or traps for either pre- or postselection of the ions of interest. The ejection of unwanted contaminant ions is performed by appropriate pulses of the potentials of deflector electrodes. These segmented ring electrodes are located off-center in the trap, i.e., between one of the two ion mirrors and the central drift tube, which also serves as a potential lift for capturing incoming ions and axially ejecting ions of interest after their selection. The various parameters affecting the selection effectivity and resolving power are illustrated with tin-cluster measurements, where isotopologue ion species provide mass differences down to a single atomic mass unit at ion masses of several hundred. Symmetric deflection voltages of only 10 V were found sufficient for the transversal ejection of ion species with as few as three deflection pulses. The duty cycle, i.e., the pulse duration with respect to the period of ion revolution, has been varied, resulting in resolving powers of up to several tens of thousands for this selection technique.

  15. Extraction of tetravalent and hexavalent actinide ions by tetraheptylammonium nitrate

    International Nuclear Information System (INIS)

    Swarup, Rajendra; Patil, S.K.

    1977-01-01

    Extraction of Th(IV), Np(IV), Pu(IV), U(VI), Np(VI), and Pu(VI) by tetraheptylammonium nitrate in Solvesso-100 has been studied from nitric acid medium. Attempts were made to identify the complex species in the organic phase by studying the dependence of the distribution coefficient of the actinide on amine concentration and taking the absorption spectra of the organic phase containing actinide ions. A compound tetraheptylammonium trinitratodioxouranate (VI) has been isolated and characterised. (author)

  16. Complexation-induced supramolecular assembly drives metal-ion extraction.

    Science.gov (United States)

    Ellis, Ross J; Meridiano, Yannick; Muller, Julie; Berthon, Laurence; Guilbaud, Philippe; Zorz, Nicole; Antonio, Mark R; Demars, Thomas; Zemb, Thomas

    2014-09-26

    Combining experiment with theory reveals the role of self-assembly and complexation in metal-ion transfer through the water-oil interface. The coordinating metal salt Eu(NO3)3 was extracted from water into oil by a lipophilic neutral amphiphile. Molecular dynamics simulations were coupled to experimental spectroscopic and X-ray scattering techniques to investigate how local coordination interactions between the metal ion and ligands in the organic phase combine with long-range interactions to produce spontaneous changes in the solvent microstructure. Extraction of the Eu(3+)-3(NO3(-)) ion pairs involves incorporation of the "hard" metal complex into the core of "soft" aggregates. This seeds the formation of reverse micelles that draw the water and "free" amphiphile into nanoscale hydrophilic domains. The reverse micelles interact through attractive van der Waals interactions and coalesce into rod-shaped polynuclear Eu(III) -containing aggregates with metal centers bridged by nitrate. These preorganized hydrophilic domains, containing high densities of O-donor ligands and anions, provide improved Eu(III) solvation environments that help drive interfacial transfer, as is reflected by the increasing Eu(III) partitioning ratios (oil/aqueous) despite the organic phase approaching saturation. For the first time, this multiscale approach links metal-ion coordination with nanoscale structure to reveal the free-energy balance that drives the phase transfer of neutral metal salts. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Metal ion extractant in microemulsions: where solvent extraction and surfactant science meet

    International Nuclear Information System (INIS)

    Bauer, C.

    2011-01-01

    The presented work describes the supramolecular structure of mixtures of a hydrophilic surfactant n-octyl-beta-glucoside (C8G1), and the hydrophobic metal ion extractant tributylphosphate (TBP) in n-dodecane/water as well as in the presence of salts. In the first part, basic solvent extraction system, composed of water, oil and extractant, will be introduced. The focus, however, lies on the extraction of multivalent metal ions from the aqueous phase. During this extraction process and in the following thermodynamic equilibrium, aggregation and phase transition in supramolecular assemblies occur, which are already described in literature. Notably, these reports rest on individual studies and specific conclusions, while a general concept is still missing. We therefore suggest the use of generalized phase diagrams to present the physico-chemical behaviour of (amphiphilic) extractant systems. These phase diagrams facilitated the development of a thermodynamic model based on molecular geometry and packing of the extractant molecules in the oil phase. As a result, we are now in the position to predict size and water content of extractant aggregates and, thus, verify the experimental results by calculation.Consequently, the second part presents a systematic study of the aqueous and organic phase of water/C8G1 and water/oil/TBP mixtures. The focus lies on understanding the interaction between metal ions and both amphiphilic molecules by means of small angle x-ray scattering (SAXS), dynamic light scattering (DLS) and UV-Vis spectroscopy. We confirmed the assumption that extraction of metal ions is driven by TBP, while C8G1 remains passive. In the third and last part, microemulsions of C8G1, TBP, water (and salt) and n-dodecane are characterized by small angle neutron scattering (SANS), and chemical analytics (Karl Fischer, total organic carbon, ICP-OES,...). The co-surfactant behaviour of TBP was highlighted by comparison to the classical n-alcohol (4≤n≤8) co

  18. Advanced integrated solvent extraction and ion exchange systems

    International Nuclear Information System (INIS)

    Horwitz, P.

    1996-01-01

    Advanced integrated solvent extraction (SX) and ion exchange (IX) systems are a series of novel SX and IX processes that extract and recover uranium and transuranics (TRUs) (neptunium, plutonium, americium) and fission products 90 Sr, 99 Tc, and 137 Cs from acidic high-level liquid waste and that sorb and recover 90 Sr, 99 Tc, and 137 Cs from alkaline supernatant high-level waste. Each system is based on the use of new selective liquid extractants or chromatographic materials. The purpose of the integrated SX and IX processes is to minimize the quantity of waste that must be vitrified and buried in a deep geologic repository by producing raffinates (from SX) and effluent streams (from IX) that will meet the specifications of Class A low-level waste

  19. Kinetic plasma simulation of ion beam extraction from an ECR ion source

    International Nuclear Information System (INIS)

    Elliott, S.M.; White, E.K.; Simkin, J.

    2012-01-01

    Designing optimized ECR (electron cyclotron resonance) ion beam sources can be streamlined by the accurate simulation of beam optical properties in order to predict ion extraction behavior. The complexity of these models, however, can make PIC-based simulations time-consuming. In this paper, we first describe a simple kinetic plasma finite element simulation of extraction of a proton beam from a permanent magnet hexapole ECR ion source. Second, we analyze the influence of secondary electrons generated by ion collisions in the residual gas on the space charge of a proton beam of a dual-solenoid ECR ion source. The finite element method (FEM) offers a fast modeling environment, allowing analysis of ion beam behavior under conditions of varying current density, electrode potential, and gas pressure. The new version of SCALA/TOSCA v14 permits the making of simulations in tens of minutes to a few hours on standard computer platforms without the need of particle-in-cell methods. The paper is followed by the slides of the presentation. (authors)

  20. Ion extraction capabilities of two-grid accelerator systems

    International Nuclear Information System (INIS)

    Rovang, D.C.; Wilbur, P.J.

    1984-02-01

    An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. This work resulted in a large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high. The apparatus developed for this study is also shown to be well suited measuring the electron backstreaming and electrical breakdown characteristics of two-grid accelerator systems

  1. Transversity: Theory and phenomenology

    Energy Technology Data Exchange (ETDEWEB)

    D' Alesio, Umberto [Dipartimento di Fisica, Universita di Cagliari, Cittadella Universitaria, and Istituto Nazionale di Fisica Nucleare, Sezione di Cagliari, C. P. 170, I-09042 Monserrato (Italy)

    2013-04-15

    The distribution of transversely polarized quarks inside a transversely polarized nucleon, known as transversity, encodes a basic piece of information on the nucleon structure, sharing the same status with the more familiar unpolarized and helicity distributions. I will review its properties and discuss different ways to access it, with highlights and limitations. Recent phenomenological extractions and perspectives are also presented.

  2. Transversity: Theory and phenomenology

    International Nuclear Information System (INIS)

    D'Alesio, Umberto

    2013-01-01

    The distribution of transversely polarized quarks inside a transversely polarized nucleon, known as transversity, encodes a basic piece of information on the nucleon structure, sharing the same status with the more familiar unpolarized and helicity distributions. I will review its properties and discuss different ways to access it, with highlights and limitations. Recent phenomenological extractions and perspectives are also presented.

  3. Study of the negative ion extraction mechanism from a double-ion plasma in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I.; Nishioka, S.; Hatayama, A. [Graduate school of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan)

    2015-04-08

    We have developed a 2D3V-PIC model of the extraction region, aiming to clarify the basic extraction mechanism of H{sup −} ions from the double-ion plasma in H{sup −} negative ion sources. The result shows the same tendency of the H{sup −} ion density n{sub H{sup −}} as that observed in the experiments, i.e.,n{sub H{sup −}} in the upstream region away from the plasma meniscus (H{sup −} emitting surface) has been reduced by applying the extraction voltage. At the same time, relatively slow temporal oscillation of the electric potential compared with the electron plasma frequency has been observed in the extraction region. Results of the systematic study using a 1D3V-PIC model with the uniform magnetic field confirm the result that the electrostatic oscillation is identified to be lower hybrid wave. The effect of this oscillation on the H{sup −} transport will be studied in the future.

  4. Axial magnetic field extraction type microwave ion source with a permanent magnet

    International Nuclear Information System (INIS)

    Ishikawa, Junzo; Takagi, Toshinori

    1984-01-01

    A new type of microwave ion source in which a permanent magnet generates an axially directed magnetic field needed for the electron cyclotron resonance was developed. The electron cyclotron resonance produces a high density plasma in the ion source. A mA-order ion beam can be extracted. Compared with usual microwave ion sources, this source has a distinguished feature in that the axially directed magnetic field is formed by use of a permanent magnet. Shape of magnetic force lines near the ion extraction aperture was carefully investigated. The extracted ion current as a function of the ion extraction voltage was measured. The experimental data are in good agreement with the theoretical line. The ion source can be heated up to 500 deg C, and extraction of the alkaline metal ions is possible. The extracted ion current for various elements are shown in the table. The current density normalized by the proton was 350-650 mA/cm 2 which was nearly equal to the upper limit of the extractable positive ion current density. The plasma density was estimated and was 2 - 3 x 10 12 cm -3 . The mass spectrum of a Cesium ion beam was obtained. A negligible amount of impurities was observed. The emittance diagram of the extracted ion beam was measured. The result shows that a low emittance and high brightness ion source is constructed. (Kato, T.)

  5. Complexation and extraction of series 4f, 5f and 4d ions by dialkyldithiophosphoric acids

    International Nuclear Information System (INIS)

    Fitoussi, Richard.

    1982-04-01

    A study was carried out on the complexing and extracting properties of various dialkyldithiophosphoric acids towards ions of the 4f, 5f and 4d series. Sulphurated donors complex and extract ions of the 4f and 5f series less strongly than their oxygenated homologues. However the affinity of trivalent actinide ions for dialkythiophosphate ions is shown to be greater than that of lanthanides. The conditions of ruthenium extraction from nitric acid are defined [fr

  6. Modeling transverse heating and outflow of ionospheric ions from the dayside cusp/cleft. 1 A parametric study

    Directory of Open Access Journals (Sweden)

    M. Bouhram

    Full Text Available The transport patterns of non-thermal H + and O + field-aligned flows from the dayside cusp/cleft, associated with transverse heating by means of wave-particle interactions and in combination with the poleward motion due to the magnetospheric convection are investigated. This has been accomplished by developing a steady-state, two-dimensional, trajectory-based code. The ion heating is modelled by means of a Monte Carlo technique, via the process of ion cyclotron resonance (ICR, with the electromagnetic left-hand circular polarized component of a broad-band, extremely low-frequency (BBELF turbulence. The altitude dependence of ICR heating from 1000 km to 3 Earth radii (RE is modelled by a power law spectrum, with an index a, and a parameter w0 that is proportional to the spectral density at a referenced gyrofrequency. Because of the finite latitudinal extent of the cusp/cleft, the incorporation of the horizontal convection drift leads to a maximum residence time tD of the ions when being energized. A large set of simulations has been computed so as to study the transport patterns of the H + and O + bulk parameters as a function of tD , a, and w0. Residence time effects are significant in O + density patterns while negligible for H +. When comparing the results with analytical one-dimensional theories (Chang et al., 1986; Crew et al., 1990, we find that mean ion energies and pitch angles at the poleward edge of the heating region are slightly influenced by tD and may be used as a probe of ICR parameters ( a, w0. Conversely, poleward of the heating region, upward velocity and mean energy dispersive patterns depend mainly on tD (e.g. the magnitude of the convection drift with latitudinal profiles varying versus

  7. A simple crunching of the AGS 'bare' machine ORM data - February 2007 - to extract some aspects of AGS transverse coupling at injection and extraction

    International Nuclear Information System (INIS)

    Ahrens, L.

    2010-01-01

    The objective of this note is to (once again) explore the AGS 'ORM' (orbit response matrix) data taken (by Operations) early during the 2007 run with an AGS bare machine and gold beam. Indeed the present motivation is to extract as much information about the AGS inherent transverse coupling as possible - from general arguments and the copious ORM data. And taking this one step further, (though not accomplished yet) the goal really should be to tell the model how to describe this coupling. 'Bare' as used here means the AGS with no quadrupole, sextupole or octupole magnets powered. Only the main (combined-function) magnet string and dipole bumps necessary to optimize beam survival are powered. 'ORM data' means the systematic recording of the equilibrium orbit beam position monitor response to powering individual dipole corrector magnets. The 'matrix' results from looking at the effect of each of the (12 superperiods X 4 dipoles per superperiod) 'kicks' on each of the (12 X 6) pick up electrodes (pues) in each transverse plane. So then we have two (48 X 72) matrices of numbers from the ORM data. (Though 'pue' usually refers to the hardware in the vacuum chamber and 'bpm' to the beam position monitoring system, the two labels will be used casually here.) The exercise is carried out at two magnet rigidities, injection (AGS field ∼434 Gauss) and extraction to RHIC (∼9730 Gauss), - a ratio of rigidities of about 22.4. Since we stick with a bare machine, we are also stuck with the bare tunes which means the tunes are rather close together and near 8.75. Injection: (h,v) ∼ (8.73, 8.76).

  8. Transverse momentum dependence of γ'/γ ratio in heavy ion collisions at LHC

    International Nuclear Information System (INIS)

    Shukla, P.; Abdulsalam, Abdulla; Kumar, Vineet

    2011-01-01

    The heavy ion collisions at high energy are performed to produce and study strongly interacting matter at high temperatures where a formation of quark gluon plasma (QGP) is expected. The most popular signal of this phase is the suppression of quarkonia due to screening by color charges. The suppression is predicted to occur above a critical temperature T c , sequentially, in order of the binding energy. It was shown many years back that the ρ T dependence of such ratio would show large variation and would be a direct probe of the QGP. In this work, the ratio γ'/γ has been calculated using essentially same model with the parameters relevant for LHC

  9. Extraction of Co ions from ion-exchange resin by supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Ju, Min Su; Koh, Moon Sung; Yang, Sung Woo; Park, Kwang Heon; Kim, Hak Won; Kim, Hong Doo

    2005-01-01

    There are a number of liquid treatment processes for eliminating radioactive ionic contaminants in nuclear facilities. One of the most common treatment methods for aqueous streams is the use of ion exchange, which is a well-developed technique that has been employed for many years in the nuclear industry. More specifically speaking, systems that ion exchange method is applied to in nuclear power plants are liquid radioactive waste treatment system, chemical and volume control system, steam generator blowdown treatment system, and service water supply system. During the operation of nuclear power plants, radioactive contaminants such as Co-60, Mn-54, Fe-59 and Cs-137 are contained in liquid radioactive wastes. And the wastes containing small amount of uranium are generated in nuclear fuel cycle facilities. To treat the liquid radioactive waste, we usually install ion exchangers rather than evaporators due to their simplicity and effectiveness, and this trend is increasing. However, the ion exchange process produces large volume of spent organic resin, and has some problems of radiation damage and thermal instability. And the reuse of the resin is limited due to the degradation of ion-exchanging ability. For this reason, were should consider a better method to expand the lifetime of the resin or to reduce the volume of radioactive resin wastes by extracting radioactive contaminants located in the resin. Supercritical fluid CO 2 has many good points as a process solvent that include low viscosity, negligible surface tension, and variable selectivity. And supercritical fluids have physical properties of both liquid and gas such as good penetration with a high dissolution capability. Supercritical fluids have been widely used in extraction, purification, and recovery processes. A number of workers applied supercritical CO 2 solvent for cleaning of precision devices and waste treatments. Since supercritical CO 2 has its mild critical point at 31 and 73.8bar as .deg. C

  10. Application of monocarboxylic acids for the extraction of metal ions-literature survey

    International Nuclear Information System (INIS)

    Brzozka, Z.; Rozycki, C.

    1980-01-01

    In the paper there is presented a literature review concerning the application of monocarboxylic acids for extraction of metal ions. The following problems are discussed: characteristic of monocarboxylic acids and their mixtures, the equilibria between the acid solution in organic solvent and aqueous phase, the mechanism of acid partition, complexes of carboxylic acids and metal ions in aqueous phase, mechanism of extraction by means of carboxylic acids as well as the problems concerning the extraction of individual metal ions. Data about the extraction of metal ions are presented in table. The 138 references are given. (author)

  11. Investigation of extraction of actinyl ions with inorganic ligands Pt. 1

    International Nuclear Information System (INIS)

    Fucks, L.; Lis, S.; Fidelis, I.

    1979-01-01

    Extraction coefficients (D) of hexavalent actinide ions have been determined by extraction chromatography, utilizing the selectivity of the TBP - HNO 3 system towards oxidation states. Plots logD against nitric acid concentration and logD against the atomic number of actinides show the decrease of extractability with Z, and a distinctly smaller difference between the extractability of uranyl and neptunyl than that of neptunyl and plutonyl ions. This latter fact is connected with the double-double effect. (A.L.)

  12. Solvent effect on the extraction and transport of lithium ions by polyethylene glycols

    International Nuclear Information System (INIS)

    Mishra, D; Sharma, U

    1999-01-01

    Extraction of lithium picrate, 2,4-dinitrophenolate and 2-nitrophenolate and their transport through membranes by di-, tri- and tetraethylene glycols as carriers are studied. Organic solvents considered as extractants and liquid membranes in terms of lithium ions extraction and transfer are arranged in the following series: methylene chloride ≥ dichloroethane ≥ chloroform ≥ carbon tetrachloride. Diethylene glycol proved the most effective solvent for lithium ions extraction and transport [ru

  13. Extractive liquid-liquid spectrophotometric procedure for the determination of thiocyanate ions employing the ion pair reagent amiloride monohydrochloride

    International Nuclear Information System (INIS)

    Bashammakh, A.S.; Bahaffi, S.O.; Al-Sibaai, A.A.; Al-Wael, H.O.; El-Shahawi, M.S.

    2007-01-01

    An accurate, inexpensive and less laborious liquid-liquid extractive spectrophotometric procedure for the determination of thiocyanate ions in aqueous media has been developed. The method has been based upon the formation of a yellow colored complex ion associate of the ion-pairing reagent 1-(3, 5-diamino-6-chloropyrazinecarboxyl) guanidine hydrochloride monohydrate, namely amiloride hydrochloride, DPG + .Cl - and the thiocyanate ions in aqueous media containing HNO 3 (0.5 mol L -1 ) and subsequent extraction with 4-methyl-2-pentanone. The absorption electronic spectrum of the ion associate showed one well-defined peak at λ max 366 nm. The stoichiometric mole ratio of DPG + .Cl - to the thiocyanate ions is 1:1.The effective molar absorptivity (ε) of the ion associate at λ max 366 nm is 1.1 ± 0.1 x 10 4 L mol -1 cm -1 . The extraction constants (K d , K ex , and β) enabled a simple and convenient use of the developed binary ion associate for the extractive spectrophotometric determination of traces of thiocyanate ions in the aqueous media. Beer's law and Ringbom's plots are obeyed in the concentration range 0.05-10 and 0.1-7 μg mL -1 of the thiocyanate ions, respectively with a relative standard deviation of ±2.3%. The calculated lower limits of detection (LOD) and quantitation (LOQ) of the developed procedure for the thiocyanate ions were found equal to 0.02 and 0.066 μg mL -1 , respectively. The developed method has been applied for the determination of trace amounts of thicyanate ions in tap-, waste- and natural water samples and compared successfully with the reported methods at the 95% confidence level. The proposed method was also applied successfully for the determination of thiocyanate ions in saliva samples

  14. Behavior of the extraction of metallic ions in carbonate medium, using N-benzoylphenylhydroxylamine (BPHA) - benzene

    International Nuclear Information System (INIS)

    Cipriani, M.

    1978-01-01

    The possibility of separating quantitatively trace impurities like Cu, Fe, In and Pb, present in uranium base materials of nuclear grade, is demonstrated. A solvent extraction is employed which makes use of -benzoylphenylhydroxylamine(BPHA)-benzene solution and separation is effected in a medium containing 252 moles per liter of sodium-uranyl tricarbonate at pH of 9,0. Carbonate ions under such conditions inhibit uranium extraction by masking uranyl ion-BPHA reaction. The uranyl ions show a demasking action, releasing, thereby, Pb(II) ions which are being extracted from carbonate medium. The Atomic Absorption Spectrophometry technique is used to obtain the experimental data [pt

  15. Extraction of negative lithium ions from a lithium-containing hydrogen plasma

    International Nuclear Information System (INIS)

    Wada, M.; Sasao, M.

    1996-01-01

    Negative lithium ions (Li - ) were extracted from a 6-cm-diam 7-cm-long negative hydrogen ion (H - ) source to simulate the condition of Li - extraction from a Li vapor introduced ion source for the neutral beam heating. The amount of the Li - current extracted from a hydrogen plasma with Li vapor was comparable to that extracted from a pure Li plasma. However, the amount of the H - current decreased as the H 2 gas pressure in the source decreased due to a getter-pump effect of Li during the introduction of Li vapor. A heat shield installed to keep a high wall temperature was effective in mitigating the pressure decrease. However, the H - current extracted from the ion source equipped with the heat shield became 20% of the original value, as Li vapor was injected into the ion source. copyright 1996 American Institute of Physics

  16. Feasibility of ion-pair/supercritical fluid extraction of an ionic compound--pseudoephedrine hydrochloride.

    Science.gov (United States)

    Eckard, P R; Taylor, L T

    1997-02-01

    The supercritical fluid extraction (SFE) of an ionic compound, pseudoephedrine hydrochloride, from a spiked-sand surface was successfully demonstrated. The effect of carbon dioxide density (CO2), supercritical fluid composition (pure vs. methanol modified), and the addition of a commonly used reversed-phase liquid chromatographic ion-pairing reagent, 1-heptanesulfonic acid, sodium salt, on extraction efficiency was examined. The extraction recoveries of pseudoephedrine hydrochloride with the addition of the ion-pairing reagent from a spiked-sand surface were shown to be statistically greater than the extraction recoveries without the ion-pairing reagent with both pure and methanol-modified carbon dioxide.

  17. High-intensity positive beams extracted from a compact double-chamber ion source

    International Nuclear Information System (INIS)

    Huck, H.; Somacal, H.; Di Gregorio, D.E.; Fernandez Niello, J.O.; Igarzabal, M.; Di Paolo, H.; Reinoso, M.

    2005-01-01

    This work presents the design and development of a simple ion source, the associated ion extraction optics, and the beam transport of a low-energy and high-current proton accelerator. In its actual version, the ion source can deliver positive proton currents up to 100 mA. This rather high beam current is achieved by adding a small ionization chamber between the discharge chamber containing the filament and the extraction electrode of the ion source. Different parameters of the ion source and the injection beam line are evaluated by means of computer simulations to optimize the beam production and transmission

  18. Two-dimensional PIC-MCC simulation of ion extraction

    International Nuclear Information System (INIS)

    Xiong Jiagui; Wang Dewu

    2000-01-01

    To explore more simple and efficient ion extraction methods used in atomic vapor laser isotope separation (AVLIS), two-dimensional (2D) PIC-MCC simulation code is used to simulate and compare several methods: parallel electrode method, II type electrode method, improved M type electrode method, and radio frequency (RF) resonance method. The simulations show that, the RF resonance method without magnetic field is the best among others, then the improved M type electrode method. The result of simulation of II type electrode method is quite different from that calculated by 2D electron equilibrium model. The RF resonance method with or without magnetic field has guide different results. Strong resonance occurs in the simulation without magnetic field, whereas no significant resonance occurs under weak magnetic field. And that is quite different from the strong resonance phenomena occurring in the 1D PIC simulation with weak magnetic field. As for practical applications, the RF resonance method without magnetic field has pros and cons, compared with the M type electrode method

  19. Extraction of partonic transverse momentum distributions from semi-inclusive deep inelastic scattering and Drell-Yan data

    Energy Technology Data Exchange (ETDEWEB)

    Pisano, Cristian [Dipartimento di Fisica, Universita di Pavia; INFN, Sezione di Pavia Via Bassi 6, I-27100 Pavia, Italy; Bacchetta, Alessandro [Dipartimento di Fisica, Universita di Pavia; INFN, Sezione di Pavia Via Bassi 6, I-27100 Pavia, Italy; Delcarro, Filippo [Dipartimento di Fisica, Universita di Pavia; INFN, Sezione di Pavia Via Bassi 6, I-27100 Pavia, Italy; Radici, Marco [INFN, Sezione di Pavia Via Bassi 6, I-27100 Pavia, Italy; Signori, Andrea [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2018-04-01

    We present a first attempt at a global fit of unpolarized quark transverse momentum dependent distribution and fragmentation functions from available data on semi-inclusive deep-inelastic scattering, Drell-Yan and $Z$ boson production processes. This analysis is performed in the low transverse momentum region, at leading order in perturbative QCD and with the inclusion of energy scale evolution effects at the next-to-leading logarithmic accuracy.

  20. The technology of uranium extraction from the brine with high chlorine-ion content

    International Nuclear Information System (INIS)

    Khakimov, N.; Nazarov, Kh.M.; Mirsaidov, I.U.; Negmatov, Sh.I.; Barotov, B.B.

    2010-01-01

    Present article is devoted to technology of uranium extraction from the brine with high chlorine-ion content. The research results on uranium extraction from the brine of Sasik-Kul Lake by means of sorption method were considered. The chemical composition of salt was determined. The process of uranium sorption was described and analyzed. The technology of uranium extraction from the brine with high chlorine-ion content was proposed.

  1. Ions extraction and collection using the RF resonance method and taking into consideration the sputtering loss

    International Nuclear Information System (INIS)

    Xie Guofeng; Wang Dewu; Ying Chuntong

    2005-01-01

    One-dimensional ions extraction and collection using the RF resonance method is studied by PIC-MCC simulation. The energy and angle distribution of extracted ions is recorded and the sputtering loss is calculated. The results show that compared with parallel electrode method, RF resonance method has advantages such as shorter extraction time, lower collision loss and sputtering loss and higher collection ratio; the extraction time and collision loss are decreased with increasing extraction voltage, but the sputtering loss increases and collection ratio decreases; collision loss is decreased with increasing magnetic field, but the sputtering loss increases and collection ratio decreases. (authors)

  2. Simulation of the CERN GTS-LHC ECR ion source extraction system with lead and argon ion beams

    CERN Document Server

    Toivanen, V; Küchler, D; Lombardi, A; Scrivens, R; Stafford-Haworth, J

    2014-01-01

    A comprehensive study of beam formation and beam transport has been initiated in order to improve the performance of the CERN heavy ion injector, Linac3. As part of this study, the ion beam extraction system of the CERN GTS-LHC 14.5 GHz Electron Cyclotron Resonance Ion Source (ECRIS) has been modelled with the ion optical code IBSimu. The simulations predict self-consistently the triangular and hollow beam structures which are often observed experimentally with ECRIS ion beams. The model is used to investigate the performance of the current extraction system and provides a basis for possible future improvements. In addition, the extraction simulation provides a more realistic representation of the initial beam properties for the beam transport simulations, which aim to identify the performance bottle necks along the Linac3 low energy beam transport. The results of beam extraction simulations with Pb and Ar ion beams from the GTS-LHC will be presented and compared with experimental observations.

  3. Microwave plasma source having improved switching operation from plasma ignition phase to normal ion extraction phase

    International Nuclear Information System (INIS)

    Sakudo, N.; Abe, K.; Koike, H.; Okada, O.; Tokiguchi, K.

    1985-01-01

    In a microwave plasma source, a discharge space supplied with a microwave electric field is supplied with a DC magnetic field. A material to be ionized is introduced into the discharge space to produce plasma, whereby ions are extracted through an ion extracting system. A switch is provided for effecting through switching operation the change-over of the magnetic field applied to the discharge space from the intensity for the ignition of plasma to the intensity for ion extraction in succession to completion of the plasma ignition

  4. On the meniscus formation and the negative hydrogen ion extraction from ITER neutral beam injection relevant ion source

    Science.gov (United States)

    Mochalskyy, S.; Wünderlich, D.; Ruf, B.; Fantz, U.; Franzen, P.; Minea, T.

    2014-10-01

    The development of a large area (Asource,ITER = 0.9 × 2 m2) hydrogen negative ion (NI) source constitutes a crucial step in construction of the neutral beam injectors of the international fusion reactor ITER. To understand the plasma behaviour in the boundary layer close to the extraction system the 3D PIC MCC code ONIX is exploited. Direct cross checked analysis of the simulation and experimental results from the ITER-relevant BATMAN source testbed with a smaller area (Asource,BATMAN ≈ 0.32 × 0.59 m2) has been conducted for a low perveance beam, but for a full set of plasma parameters available. ONIX has been partially benchmarked by comparison to the results obtained using the commercial particle tracing code for positive ion extraction KOBRA3D. Very good agreement has been found in terms of meniscus position and its shape for simulations of different plasma densities. The influence of the initial plasma composition on the final meniscus structure was then investigated for NIs. As expected from the Child-Langmuir law, the results show that not only does the extraction potential play a crucial role on the meniscus formation, but also the initial plasma density and its electronegativity. For the given parameters, the calculated meniscus locates a few mm downstream of the plasma grid aperture provoking a direct NI extraction. Most of the surface produced NIs do not reach the plasma bulk, but move directly towards the extraction grid guided by the extraction field. Even for artificially increased electronegativity of the bulk plasma the extracted NI current from this region is low. This observation indicates a high relevance of the direct NI extraction. These calculations show that the extracted NI current from the bulk region is low even if a complete ion-ion plasma is assumed, meaning that direct extraction from surface produced ions should be present in order to obtain sufficiently high extracted NI current density. The calculated extracted currents, both ions

  5. Transport and extraction of radioactive ions stopped in superfluid helium

    NARCIS (Netherlands)

    Huang, WX; Dendooven, P; Gloos, K; Takahashi, N; Arutyunov, K; Pekola, JP; Aysto, J

    A new approach to convert a high energy beam to a low energy one, which is essential for the next generation radioactive ion beam facilities, has been proposed and tested at Jyvaskyla, Finland. An open Ra-223 alpha-decay-recoil source has been used to produce radioactive ions in superfluid helium.

  6. Extraction of low-energy negative oxygen ions for thin film formation

    International Nuclear Information System (INIS)

    Vasquez, M. Jr.; Sasaki, D.; Kasuya, T.; Wada, M.; Maeno, S.

    2011-01-01

    Coextraction of low-energy positive and negative ions were performed using a plasma sputter-type ion source system driven by a 13.56 MHz radio frequency (rf) power. Titanium (Ti) atoms were sputtered out from a target and the sputtered neutrals were postionized in oxygen/argon (O 2 /Ar) plasma prior to extraction. The negative O ions were surface-produced and self-extracted. Mass spectral analyses of the extracted ion beams revealed the dependence of the ion current on the incident rf power, induced target bias and O 2 /Ar partial pressure ratio. Ti + current was found to be dependent on Ar + current and reached a saturation value with increasing O 2 partial pressure while the O - current showed a peak current at around 1:9 O 2 /Ar partial pressure ratio. Ti + current was several orders of magnitude higher than that of the O - current.

  7. On the meniscus formation and the negative hydrogen ion extraction from ITER neutral beam injection relevant ion source

    International Nuclear Information System (INIS)

    Mochalskyy, S; Wünderlich, D; Ruf, B; Fantz, U; Franzen, P; Minea, T

    2014-01-01

    The development of a large area (A source,ITER  = 0.9 × 2 m 2 ) hydrogen negative ion (NI) source constitutes a crucial step in construction of the neutral beam injectors of the international fusion reactor ITER. To understand the plasma behaviour in the boundary layer close to the extraction system the 3D PIC MCC code ONIX is exploited. Direct cross checked analysis of the simulation and experimental results from the ITER-relevant BATMAN source testbed with a smaller area (A source,BATMAN  ≈ 0.32 × 0.59 m 2 ) has been conducted for a low perveance beam, but for a full set of plasma parameters available. ONIX has been partially benchmarked by comparison to the results obtained using the commercial particle tracing code for positive ion extraction KOBRA3D. Very good agreement has been found in terms of meniscus position and its shape for simulations of different plasma densities. The influence of the initial plasma composition on the final meniscus structure was then investigated for NIs. As expected from the Child–Langmuir law, the results show that not only does the extraction potential play a crucial role on the meniscus formation, but also the initial plasma density and its electronegativity. For the given parameters, the calculated meniscus locates a few mm downstream of the plasma grid aperture provoking a direct NI extraction. Most of the surface produced NIs do not reach the plasma bulk, but move directly towards the extraction grid guided by the extraction field. Even for artificially increased electronegativity of the bulk plasma the extracted NI current from this region is low. This observation indicates a high relevance of the direct NI extraction. These calculations show that the extracted NI current from the bulk region is low even if a complete ion–ion plasma is assumed, meaning that direct extraction from surface produced ions should be present in order to obtain sufficiently high extracted NI current density. The calculated

  8. 4f and 5f trivalent ions complexation by diamides and uses in solvent extraction

    International Nuclear Information System (INIS)

    Huber, H.

    1984-06-01

    Extractive properties of N,N'-tetraalkylmalonamides were investigated in view to separate the actinides contained in highly radioactive wastes. N,N'-dimethyldioctylmalonamide (DMDOMA) was selected. It extracts trivalent actinide and lanthanide from concentrated nitric acid. Mineral acids extraction was studied, especially HNO 3 extraction. The distribution of HNO 3 can be interpreted by assuming that in the organic phase three main species are present: HNO 3 (DMDOMA) 2 , HNO 3 DMDOMA, (HNO 3 ) 2 DMDOMA. 5f and 4f trivalent ions are extracted according to the mechanism: M 3+ + 3NO 3 - + 4DMDOMA in equilibrium with [M(DMDOMA) 2 (NO 3 ) 3 ].(DMDOMA) 2 . The extraction of important ions like U(VI), Np(V), Pu(IV), Pu(VI), Zr(IV) and Fe(III) was investigated. The results showed that DMDOMA behave line the carbamoylmethylenephosphonates and could be an interesting alternative to these organophosphorus extractants [fr

  9. The virtual cathode: Key to the numerical simulation of negative ion extraction

    International Nuclear Information System (INIS)

    Becker, R.; Leung, K.N.; Kunkel, W.

    1998-01-01

    The simulation of volume produced negative ions from a plasma is by far more complicated than the extraction of positive ions, while in experiments the only difficulty seemes to be connected with the power of the electrons, which are extracted at the same time. The reason for this complication in simple minded simulations is the infinite space charge, which builds up in the turning point of the positive ions in the extraction aperture for the negative ions. Smearing out the energy of the positive ions seems to help, however, this is mostly not justified by experiments, showing a low ion energy, especially in the region between the magnetic filter and the extraction hole. This difficulty may be overcome by using experience from virtual cathode formation in magnetically focused, decelerated electron beams. The decelerated electrons behave similarly to the reflected positive ions and are forming a virtual cathode in the reflection zone. From the analysis of the electron deceleration experiment, a simple power law is deduced to describe the decreasing electron current by the local potential. In turn, this power law may also be applied to the positive ion current, resulting in simulations without space charge singularity, even in the case of monoenergetic ions. As a first step towards the numerical simulation of negative ion extraction, a linear model has been made, using this power law. The transition from a Boltzmann distribution for the plasma electrons to a truncated one for the extracted beam electrons is considered as well, parallel to Langmuir close-quote s treatment of a thermal diode for electrons. copyright 1998 American Institute of Physics

  10. Extraction of highly charged ions from the Berlin Electron Beam Ion Trap for interactions with a gas target

    International Nuclear Information System (INIS)

    Allen, F.I.; Biedermann, C.; Radtke, R.; Fussmann, G.

    2006-01-01

    Highly charged ions are extracted from the Berlin Electron Beam Ion Trap for investigations of charge exchange with a gas target. The classical over-the-barrier model for slow highly charged ions describes this process, whereby one or more electrons are captured from the target into Rydberg states of the ion. The excited state relaxes via a radiative cascade of the electron to ground energy. The cascade spectra are characteristic of the capture state. We investigate x-ray photons emitted as a result of interactions between Ar 17+ ions at energies ≤5q keV with Ar atoms. Of particular interest is the velocity dependence of the angular momentum capture state l c

  11. Simulation studies of the extraction region from glow discharge ion sources

    International Nuclear Information System (INIS)

    Abdelrahman, M.M.

    2012-01-01

    This paper studies the influence of various parameters and conditions on the performance of an ion-beam extraction system, the trajectories of the particles in the beam being simulated by a commercial software (SIMION 3D). Space-charge effects are accounted for and criteria allowing optimization of the system are proposed. Ion beam trajectories with and without space charge have been determined and, from the results, optimum extraction conditions have been deduced. Simulation of singly charged ion trajectories for a concave meniscus with 3.5 mm curvature radius was studied with and without space charge has been done using a singly charge argon ion trajectories. Firstly, for a concave meniscus with 3.5 mm curvature radius, the influence of the current density on the ion beam shape was investigated. Furthermore, influence of the extraction voltage applied to the extraction electrode on the ion beam envelope was studied. Finally, the influence of the extraction gap width on the ion beam envelope was also studied

  12. Isolation of nitrosylruthenium nitrato complexes by ion exchange and extraction chromatography

    International Nuclear Information System (INIS)

    Huang, H.; Liu, L.

    TBP Levextrel and cation exchange resins were used to separate RuNO nitrato complexes of different nitric acid concentrations. 7402 quaternary ammonium salt Levextrel was used instead of an anionic exchange resin to separate anionic and neutral complex ions. The results indicated that D 3 and D 4 , which can easily be extracted by TBP, were anionic and neutral complex ions

  13. Application of ion-exchange unit in uranium extraction process in China (to be continued)

    International Nuclear Information System (INIS)

    Gong Chuanwen

    2004-01-01

    The application conditions of five different ion exchange units in uranium milling plant and wastewater treatment plant of uranium mine in China are introduced, including working parameters, existing problems and improvements. The advantages and disadvantages of these units are reviewed briefly. The procedure points to be followed in selecting ion exchange unit are recommended in the engineering design. The primary views are presented upon the application prospects of some ion exchange units in uranium extraction process in China

  14. Characterization of an ion beam produced by extraction and acceleration of ions from a wire plasma source

    International Nuclear Information System (INIS)

    Gueroult, R.

    2011-09-01

    In this study we first model a DC low pressure wire plasma source and then characterize the properties of an ion gun derived from the plasma source. In order to study the properties of the derived ion gun, we develop a particle-in-cell code fitted to the modelling of the wire plasma source operation, and validate it by confrontation with the results of an experimental study. In light of the simulation results, an analysis of the wire discharge in terms of a collisional Child-Langmuir ion flow in cylindrical geometry is proposed. We interpret the mode transition as a natural reorganization of the discharge when the current is increased above a threshold value which is a function of the discharge voltage, the pressure and the inter-electrodes distance. In addition, the analysis of the energy distribution function of ions impacting the cathode demonstrates the ability to extract an ion beam of low energy spread around the discharge voltage assuming that the discharge is operated in its high pressure mode. An ion source prototype allowing the extraction and acceleration of ions from the wire source is then proposed. The experimental study of such a device confirms that, apart from a shift corresponding to the accelerating voltage, the acceleration scheme does not spread the ion velocity distribution function along the axis of the beam. It is therefore possible to produce tunable energy (0 - 5 keV) ion beams of various ionic species presenting limited energy dispersion (∼ 10 eV). The typical beam currents are about a few tens of micro-amperes, and the divergence of such a beam is on the order of one degree. A numerical modelling of the ion source is eventually conducted in order to identify potential optimizations of the concept. (author)

  15. Extracting metal ions with diphosphonic acid, or derivative thereof

    Science.gov (United States)

    Horwitz, Earl P.; Gatrone, Ralph C.; Nash, Kenneth L.

    1994-01-01

    Thermodynamically-unstable complexing agents which are diphosphonic acids and diphosphonic acid derivatives (or sulphur containing analogs), like carboxyhydroxymethanediphosphonic acid and vinylidene-1,1-diphosphonic acid, are capable of complexing with metal ions, and especially metal ions in the II, III, IV, V and VI oxidation states, to form stable, water-soluble metal ion complexes in moderately alkaline to highly-acidic media. However, the complexing agents can be decomposed, under mild conditions, into non-organic compounds which, for many purposes are environmentally-nondamaging compounds thereby degrading the complex and releasing the metal ion for disposal or recovery. Uses for such complexing agents as well as methods for their manufacture are also described.

  16. Extracting metal ions with diphosphonic acid, or derivative thereof

    Science.gov (United States)

    Horwitz, E.P.; Gatrone, R.C.; Nash, K.L.

    1994-07-26

    Thermodynamically-unstable complexing agents which are diphosphonic acids and diphosphonic acid derivatives (or sulfur containing analogs), like carboxyhydroxymethanediphosphonic acid and vinylidene-1,1-diphosphonic acid, are capable of complexing with metal ions, and especially metal ions in the II, III, IV, V and VI oxidation states, to form stable, water-soluble metal ion complexes in moderately alkaline to highly-acidic media. However, the complexing agents can be decomposed, under mild conditions, into non-organic compounds which, for many purposes are environmentally-nondamaging compounds thereby degrading the complex and releasing the metal ion for disposal or recovery. Uses for such complexing agents as well as methods for their manufacture are also described. 1 fig.

  17. Jet laser ion source

    International Nuclear Information System (INIS)

    Dem'yanov, A.V.; Sidorov, S.V.

    1994-01-01

    External laser injector of multicharged ions (MCI) is developed in which wide-aperture aberration-free wire gauze spherical shape electrodes are applied for effective MCI extraction from laser plasma and beam focusing. Axial plasma compression by solenoid magnetic field is used to reduce ion losses due to transverse movement of the scattering laser plasma. Transverse magnetic field created by another solenoid facilitates the effective laser plasma braking and consequently, leads to the narrowing of energy spectrum of plasma ions and its shift towards lower energies. 2 refs.; 3 figs

  18. Solid-phase extraction (SPE) of Iron using Lanthanum Silicate ion exchange

    International Nuclear Information System (INIS)

    Kiarostami, V.; Husain, W.

    2002-01-01

    Solid-phase extraction (SPE) is gaining wide use as an effective and speedy technique which reduces solvent usage, disposal costs and extraction time. The analyte is adsorbed from solution onto a solid adsorbent, which is followed by elution of the analyte with a solvent appropriate for instrumental analysis. However, there is an increasing need for new selective adsorbents to expand the area of this technique. Lanthanum silicate ion exchanger, which shows unusual selectivity elements and in this study, it was employed to develop a SPE method for iron ion. Special experiments such as determination of distribution coefficient for iron ion in different solvent systems have been determined

  19. POLY(AMINOMETHYLENEPHOSPHONIC ACID FOR SOLVENT EXTRACTION OF METAL IONS

    Directory of Open Access Journals (Sweden)

    M’hamed Kaid

    2011-09-01

    Full Text Available Diaminododecyltetramethylenetetraphosphonic acid (DADTMTPA has been investigated in liquid - liquid extraction of Zn (II and Cu (II in acetate media. The extraction of both cations was carried out in different media with the addition of CH3COONa, CH3COOH, HCl and H2SO4 at different pH values. The maximum extraction yield for copper is 70% after addition of 10 mg of sodium acetate and for zinc is 30% after addition of acetic acid at pHi = 5.5, in one step.

  20. Thermo-mechanical design of the extraction grids for RF negative ion source at HUST

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Chen; Liu, Kaifeng, E-mail: kfliuhust@hust.edu.cn; Li, Dong; Mei, Zhiyuan; Zhang, Zhe; Chen, Dezhi

    2017-01-15

    Highlights: • An extraction system with cooling channels has been designed for HUST negative ion source. • Corresponding heat loads onto three grids has been used in thermo-mechanical analysis. • The analysis results could be very useful for driving the engineering design. - Abstract: Huazhong University of Science and Technology (HUST) is developing a small radio frequency negative ion source experimental setup to promote research on neutral beam injection ion sources. The extraction system for the negative ion source is the key component to obtain the negative ions. The extraction system is composed of three grids: the plasma grid, the extraction grid and the grounded grid. Each grid is impacted by different heat loads. As the grids have to fulfil specific requirements regarding ion extraction, beam optics, and thermo-mechanical issues, grid cooling systems have been included for ensuring reliable operation. This paper focuses on the thermo-hydraulic and thermo-mechanical design of the grids. Finite element calculations have been carried out to analyse the temperature and deformation of the grids under heat loads using the fluid dynamics code CFX. Based on these results, the cooling circuit design and cooling parameters are optimised to satisfy the grid requirements.

  1. Studies for determining thermal ion extraction potential for aluminium plasma generated by electron beam evaporator

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, V Dileep; Barnwal, Tripti A; Mukherjee, Jaya; Gantayet, L M, E-mail: dileepv@barc.gov.i [Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai-400085 (India)

    2010-02-01

    For effective evaporation of refractory metal, electron beam is found to be most suitable vapour generator source. Using electron beam, high throughput laser based purification processes are carried out. But due to highly concentrated electron beam, the vapour gets ionised and these ions lead to dilution of the pure product of laser based separation process. To estimate the concentration of these ions and extraction potential requirement to remove these ions from vapour stream, experiments have been conducted using aluminium as evaporant. The aluminium ingots were placed in water cooled copper crucible. Inserts were used to hold the evaporant, in order to attain higher number density in the vapour processing zone and also for confining the liquid metal. Parametric studies with beam power, number density and extraction potential were conducted. In this paper we discuss the trend of the generation of thermal ions and electrostatic field requirement for extraction.

  2. Extraction and detection of arsenicals in seaweed via accelerated solvent extraction with ion chromatographic separation and ICP-MS detection

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, P.A.; Shoemaker, J.A.; Wei Xinyi; Brockhoff-Schwegel, C.A.; Creed, J.T. [Microbiological and Chemical Exposure Assessment Research Div., Cincinnati, OH (United States)

    2001-01-01

    An accelerated solvent extraction (ASE) device was evaluated as a semi-automated means of extracting arsenicals from ribbon kelp. The effect of the experimentally controllable ASE parameters (pressure, temperature, static time, and solvent composition) on the extraction efficiencies of arsenicals from seaweed was investigated. The extraction efficiencies for ribbon kelp (approximately 72.6%) using the ASE were fairly independent (< 7%) of pressure, static time and particle size after 3 ASE extraction cycles. The optimum extraction conditions for the ribbon kelp were obtained by using a 3 mL ASE cell, 30/70 (w/w) MeOH/H{sub 2}O, 500 psi (1 psi = 7 KPa), ambient temperature, 1 min heat step, 1 min static step, 90% vol. flush, and a 120 s purge. Using these conditions, two other seaweed products produced extraction efficiencies of 25.6% and 50.5%. The inorganic species present in the extract represented 62.5% and 27.8% of the extracted arsenic. The speciation results indicated that both seaweed products contained 4 different arsenosugars, DMA (dimethylarsinic acid), and As(V). One seaweed product also contained As(III). Both of these seaweed products contained an arsenosugar whose molecular weight was determined to be 408 and its structure was tentatively identified using ion chromatography-electrospray ionization-mass spectrometry/mass spectrometry (IC-ESI-MS/MS). (orig.)

  3. Extraction of metal ions through ligand assisted ionic liquids

    International Nuclear Information System (INIS)

    Kumar, P.; Vincent, T.; Khanna, A.

    2014-01-01

    Extraction of Strontium by crown ether (DCH18C6) has been investigated in [BMIM][TF2N] Ionic Liquid (IL) giving higher extraction ~98% and distribution ratio as compared to other organic solvents (Dodecane, Hexane, & Isodecyl alcohol + Dodecane). Distribution ratio of Sr in IL at 0.15M DCH18C6 indicates an enhancement of 20000, 2000, 500 times over Dodecane, Hexane and 5% Isodecyl Alcohol + 95 % Dodecane at 0.01M aqueous acidity respectively. In presence of IL Sr extraction decreases with increase in HNO 3 concentration in aqueous phase whereas opposite trend was observed with organic solvents. Extraction of Sr initially increases with increase in DCH18C6 concentration in IL, finally reaching an asymptotic constant. Sr can be stripped from the organic phase by precipitating with K 2 SO 4 . (author)

  4. Separation and Extraction of Some Heavy and Toxic Metal Ions from Their Wastes by Ionic Membranes

    International Nuclear Information System (INIS)

    El-Sayed Hegazy, A.; Kamal, H.; Mahmoud, Gh. A.; Khalifa, N.A.

    1999-01-01

    Preparation and characterisation of a series of ion-exchange membranes for the purpose of separation and extraction of some heavy and toxic metal ions from their wastes have been studied. Such ion exchange membranes prepared by γ-radiation grafting of acrylonitrile (AN) and vinyl acetate (VAc) in a binary monomers mixture onto low density polyethylene (LDPE) using direct technique of grafting. The reaction conditions at which grafting process proceeds successfully have been determined. Many modification treatments have been attempted for the prepared membranes to improve their ion-exchange properties. The possibility of their practical use in waste water treatment from some heavy and toxic metal ions such as Pb 2+ , Cd 2+ ,Cu 2+ ,Fe 3+ ,Sr 2+ and Li + have been investigated. These grafted membranes showed great promise for its use in the field of extraction and removal of some heavy and toxic metals from their wastes

  5. Synergism of thiocyanate ions and microinterfacial surface as driving forces for heavy multi-metals extraction

    Directory of Open Access Journals (Sweden)

    Daniela Cadar

    2018-05-01

    Full Text Available A comprehensive study has been carried out to evaluate the extraction of heavy metals mixture (Co2+, Cr3+, Cu2+, Ni2+ from aqueous media by Winsor II non-ionic microemulsion, containing polyoxyethylene (4 lauryl ether as non-ionic surfactant and butyl acetate as organic phase. The extraction mechanism is based on the formation of thiocyanate complexes of metals and their transfer from aqueous to microemulsion phase, either towards the interfacial film of surfactant (Co2+ or into the core of micelles (Cr3+, Cu2+, Ni2+. The value of the distribution coefficient for Co2+ was higher than for the other studied metals and its extraction efficiency was not dependent on the working conditions, showing a maximum value (99.99% in all cases. By using successive extractions, chromium, nickel and copper ions that remained in the aqueous phase after first extraction were transported into the microemulsion phase, leading to an increase in the extraction efficiency up to 99.99% for chromium and copper, and 85% for nickel. Based on pH influence, a selective extraction of Co2+ and Cr3+ can be achieved, since the cobalt ions were completely extracted into the microemulsion phase at pH = 1, and the chromium ions still remained in the aqueous phase. Keywords: Nonionic microemulsion, Thiocyanate complexes of heavy metals, Simultaneous heavy metals extraction, Microinterfacial effect, Synergism

  6. Decontamination of Metal Ions in Soil by Supercritical CO2 Extraction with Crown Ether

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jihe; Park, Kwangheon [Kyunghee University, Yongin (Korea, Republic of)

    2015-05-15

    Previous decontamination methods have shortcomings in that they produce additional waste due to the usage of solutions with chemical toxicity. Hence, demand is strong for new decontamination methods that can guarantee effective decontamination while decreasing the chemical solution. In particular, methods using supercritical CO2 as a means of decontamination are currently in progress. This study examines the method of decontaminating metallic ions inside soil using supercritical CO2. This paper examined the effects of extracting metallic ions inside soil using supercritical CO2 and crown ether as the ligand. It was confirmed that extraction effectiveness increases following greater usage of ligand and co-ligand, with a drastic increase in extraction effectiveness when using extracts over a certain dose. Moreover, it was shown that if the usage of ligand and additive decreases, the extraction ratio also decreases.

  7. Decontamination of Metal Ions in Soil by Supercritical CO2 Extraction with Crown Ether

    International Nuclear Information System (INIS)

    Park, Jihe; Park, Kwangheon

    2015-01-01

    Previous decontamination methods have shortcomings in that they produce additional waste due to the usage of solutions with chemical toxicity. Hence, demand is strong for new decontamination methods that can guarantee effective decontamination while decreasing the chemical solution. In particular, methods using supercritical CO2 as a means of decontamination are currently in progress. This study examines the method of decontaminating metallic ions inside soil using supercritical CO2. This paper examined the effects of extracting metallic ions inside soil using supercritical CO2 and crown ether as the ligand. It was confirmed that extraction effectiveness increases following greater usage of ligand and co-ligand, with a drastic increase in extraction effectiveness when using extracts over a certain dose. Moreover, it was shown that if the usage of ligand and additive decreases, the extraction ratio also decreases

  8. Polyaspartate extraction of cadmium ions from contaminated soil: Evaluation and optimization using central composite design.

    Science.gov (United States)

    Mu'azu, Nuhu Dalhat; Haladu, Shamsuddeen A; Jarrah, Nabeel; Zubair, Mukarram; Essa, Mohammad H; Ali, Shaikh A

    2018-01-15

    The occurrences of heavy metal contaminated sites and soils and the need for devising environmentally friendly solutions have become global issues of serious concern. In this study, polyaspartate (a highly biodegradable agent) was synthesized using L-Aspartic acid via a new modified thermal procedure and employed for extraction of cadmium ions (Cd) from contaminated soil. Response surface methodology approach using 3 5 full faced centered central composite design was employed for modeling, evaluating and optimizing the influence of polyaspartate concentration (36-145mM), polyaspartate/soil ratio (5-25), initial heavy metal concentration (100-500mg/kg), initial pH (3-6) and extraction time (6-24h) on Cd ions extracted into the polyaspartate solution and its residual concentration in the treated soil. The Cd extraction efficacy obtained reached up to 98.8%. Increase in Cd extraction efficiency was associated with increase in the polyaspartate and Cd concentration coupled with lower polyaspertate/soil ratio and initial pH. Under the optimal conditions characterized with minimal utilization of the polyaspartate and high Cd ions removal, the extractible Cd in the polyaspartate solution reached up to 84.4mg/L which yielded 85% Cd extraction efficacy. This study demonstrates the suitability of using polyaspartate as an effective environmentally friendly chelating agent for Cd extraction from contaminated soils. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Investigation of metal ion extraction and aggregate formation combining acidic and neutral organophosphorous reagents

    Energy Technology Data Exchange (ETDEWEB)

    Braatz, A.D.; Nilsson, M. [Department of Chemical Engineering and Materials Science, 916 Engineering Tower, University of California-Irvine, Irvine, CA 92697-2575 (United States); Ellis, R.; Antonio, M. [Chemical Science and Engineering Division, Argonne National Laboratory, Building 200 9700 South Cass Ave, Argonne, IL 60439-4831 (United States)

    2013-07-01

    In the present study, we investigate how varying mixtures of tri-n-butyl phosphate (TBP) and dibutyl phosphate (HDBP) results in enhanced extraction of lanthanum(III), La{sup 3+}, and dysprosium(III), Dy{sup 3+}. Water and metal ion extraction were carefully monitored as a function of TBP:HDBP mole ratio.In addition to these techniques, EXAFS was used to determine the coordination environment of the metal ion in this system. To produce the necessary signal, a concentration of 1.25*10{sup -3} M La{sup 3+} and Dy{sup 3+} was used. Although previous studies of synergistic extraction of metal cations using combinations of neutral and acidic reagents explain the enhanced extraction by increased dehydration of the metal ion and the formation of mixed extractant complexes, our evidence for the increased water extraction coupled with the aggregate formation suggests a reverse micellar aspect to synergism in the system containing TBP and HDBP. It is quite possible that both of these phenomena contribute to our system behavior. The EXAFS data shows that, based on coordination numbers alone, several possible structures may exist. From this study, we cannot provide a definitive answer as to the nature of extraction in this system or the exact complex formed during extraction.

  10. First results from negative ion beam extraction in ROBIN in surface mode

    Science.gov (United States)

    Pandya, Kaushal; Gahlaut, Agrajit; Yadav, Ratnakar K.; Bhuyan, Manas; Bandyopadhyay, Mainak; Das, B. K.; Bharathi, P.; Vupugalla, Mahesh; Parmar, K. G.; Tyagi, Himanshu; Patel, Kartik; Bhagora, Jignesh; Mistri, Hiren; Prajapati, Bhavesh; Pandey, Ravi; Chakraborty, Arun. K.

    2017-08-01

    ROBIN, the first step in the Indian R&D program on negative ion beams has reached an important milestone, with the production of negative ions in the surface conversion mode through Cesium (Cs) vapor injection into the source. In the present set-up, negative hydrogen ion beam extraction is effected through an extraction area of ˜73.38 cm2 (146 apertures of 8mm diameter). The three grid electrostatic accelerator system of ROBIN is fed by high voltage DC power supplies (Extraction Power Supply System: 11kV, 35A and Acceleration Power Supply System: 35kV, 15A). Though, a considerable reduction of co-extracted electron current is usually observed during surface mode operation, in order to increase the negative ion current, various other parameters such as plasma grid temperature, plasma grid bias, extraction to acceleration voltage ratio, impurity control and Cs recycling need to be optimized. In the present experiments, to control and to understand the impurity behavior, a Cryopump (14,000 l/s for Hydrogen) is installed along with a Residual Gas Analyzer (RGA). To characterize the source plasma, two sets of Langmuir probes are inserted through the diagnostic flange ports available at the extraction plane. To characterize the beam properties, thermal differential calorimeter, Doppler Shift Spectroscopy and electrical current measurements are implemented in ROBIN. In the present set up, all the negative ion beam extraction experiments have been performed by varying different experimental parameters e.g. RF power (30-70 kW), source operational pressure (0.3 - 0.6Pa), plasma grid bias voltage, extraction & acceleration voltage combination etc. The experiments in surface mode operation is resulted a reduction of co-extracted electron current having electron to ion ratio (e/i) ˜2 whereas the extracted negative ion current density was increased. However, further increase in negative ion current density is expected to be improved after a systematic optimization of the

  11. Extraction of alginate biopolymer present in marine alga sargassum filipendula and bioadsorption of metallic ions

    Directory of Open Access Journals (Sweden)

    Sirlei Jaiana Kleinübing

    2013-04-01

    Full Text Available This paper studies the bioadsorption of Pb2+, Cu2+, Cd2+ and Zn2+ ions by marine alga Sargassum filipendula and by the alginate biopolymer extracted from this alga. The objective is to evaluate the importance of this biopolymer in removing different metallic ions by the marine alga S. filipendula. In the equilibrium study, the same affinity order was observed for both bioadsorbents: Pb2+ > Cu2+ > Zn2+ > Cd2+. For Pb2+ and Cu2+ ions when the alginate is isolated and acting as bioadsorbents, adsorption capacities greater than those found for the alga were observed, indicating that it is the main component responsible for the removal of metallic ions. For Zn2+ and Cd2+ ions, greater bioadsorption capacities were observed for the alga, indicating that other functional groups of the alga, such as sulfates and amino, are also important in the bioadsorption of these ions.

  12. Apparatus and method for extracting power from energetic ions produced in nuclear fusion

    Science.gov (United States)

    Fisch, Nathaniel J.; Rax, Jean M.

    1994-01-01

    An apparatus and method of extracting power from energetic ions produced by nuclear fusion in a toroidal plasma to enhance respectively the toroidal plasma current and fusion reactivity. By injecting waves of predetermined frequency and phase traveling substantially in a selected poloidal direction within the plasma, the energetic ions become diffused in energy and space such that the energetic ions lose energy and amplify the waves. The amplified waves are further adapted to travel substantially in a selected toroidal direction to increase preferentially the energy of electrons traveling in one toroidal direction which, in turn, enhances or generates a toroidal plasma current. In an further adaptation, the amplified waves can be made to preferentially increase the energy of fuel ions within the plasma to enhance the fusion reactivity of the fuel ions. The described direct, or in situ, conversion of the energetic ion energy provides an efficient and economical means of delivering power to a fusion reactor.

  13. Towards a realistic 3D simulation of the extraction region in ITER NBI relevant ion source

    Science.gov (United States)

    Mochalskyy, S.; Wünderlich, D.; Fantz, U.; Franzen, P.; Minea, T.

    2015-03-01

    The development of negative ion (NI) sources for ITER is strongly accompanied by modelling activities. The ONIX code addresses the physics of formation and extraction of negative hydrogen ions at caesiated sources as well as the amount of co-extracted electrons. In order to be closer to the experimental conditions the code has been improved. It includes now the bias potential applied to first grid (plasma grid) of the extraction system, and the presence of Cs+ ions in the plasma. The simulation results show that such aspects play an important role for the formation of an ion-ion plasma in the boundary region by reducing the depth of the negative potential well in vicinity to the plasma grid that limits the extraction of the NIs produced at the Cs covered plasma grid surface. The influence of the initial temperature of the surface produced NI and its emission rate on the NI density in the bulk plasma that in turn affects the beam formation region was analysed. The formation of the plasma meniscus, the boundary between the plasma and the beam, was investigated for the extraction potentials of 5 and 10 kV. At the smaller extraction potential the meniscus moves closer to the plasma grid but as in the case of 10 kV the deepest meniscus bend point is still outside of the aperture. Finally, a plasma containing the same amount of NI and electrons (nH- =ne =1017 m-3) , representing good source conditioning, was simulated. It is shown that at such conditions the extracted NI current can reach values of ˜32 mA cm-2 using ITER-relevant extraction potential of 10 kV and ˜19 mA cm-2 at 5 kV. These results are in good agreement with experimental measurements performed at the small scale ITER prototype source at the test facility BATMAN.

  14. Extraction of volume produced H- or D- ions from a sheet plasma, 2

    International Nuclear Information System (INIS)

    Uramoto, Joshin.

    1984-02-01

    A development to large area H - or D - ion source is tried by using three extraction electrodes: The first electrode bias voltage is set near the wall potential (floating), the second electrode is set near 13 % of main extraction voltage and the third electrode is the main acceleration electrode. An ion current of 13 mA (3.3 mA/cm 2 ) for H - or 11 mA (2.8 mA/ cm 2 ) for D - at 3 KeV is extracted from 9 apertures of 6 mm phi in 4 cm 2 outside of the sheet plasma (14 cm wide and 1.0 cm thick) under a pressure of 7.7 x 10 -4 H2 or D2 gas and a weak magnetic field 50 gauss. Then, it is noted that the corresponding electron current is suppressed below 1/10 of the H - or D - ion current. (author)

  15. Excitation of transverse dipole and quadrupole modes in a pure ion plasma in a linear Paul trap to study collective processes in intense beams

    Energy Technology Data Exchange (ETDEWEB)

    Gilson, Erik P.; Davidson, Ronald C.; Efthimion, Philip C.; Majeski, Richard; Startsev, Edward A.; Wang, Hua [Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States); Koppell, Stewart [University of Texas at Austin, Austin, Texas 78712 (United States); Talley, Matthew [Brigham Young University, Provo, Utah 84602 (United States)

    2013-05-15

    Transverse dipole and quadrupole modes have been excited in a one-component cesium ion plasma trapped in the Paul Trap Simulator Experiment (PTSX) in order to characterize their properties and understand the effect of their excitation on equivalent long-distance beam propagation. The PTSX device is a compact laboratory Paul trap that simulates the transverse dynamics of a long, intense charge bunch propagating through an alternating-gradient transport system by putting the physicist in the beam's frame of reference. A pair of arbitrary function generators was used to apply trapping voltage waveform perturbations with a range of frequencies and, by changing which electrodes were driven with the perturbation, with either a dipole or quadrupole spatial structure. The results presented in this paper explore the dependence of the perturbation voltage's effect on the perturbation duration and amplitude. Perturbations were also applied that simulate the effect of random lattice errors that exist in an accelerator with quadrupole magnets that are misaligned or have variance in their field strength. The experimental results quantify the growth in the equivalent transverse beam emittance that occurs due to the applied noise and demonstrate that the random lattice errors interact with the trapped plasma through the plasma's internal collective modes. Coherent periodic perturbations were applied to simulate the effects of magnet errors in circular machines such as storage rings. The trapped one component plasma is strongly affected when the perturbation frequency is commensurate with a plasma mode frequency. The experimental results, which help to understand the physics of quiescent intense beam propagation over large distances, are compared with analytic models.

  16. Operation of passive wax flashover and LiF ion sources on extraction applied-B ion diodes on SABRE

    International Nuclear Information System (INIS)

    Cuneo, M.E.; Hanson, D.L.; Smith, J.R.; Rosenthal, S.E.; Coats, R.S.; Bernard, M.A.

    1993-01-01

    The authors are fielding wax flashover and LiF anodes on an extraction ion diode on SABRE (Sandia Accelerator and Beam Research Experiment), a magnetically insulated linear induction voltage adder, presently providing a 6 MV, 300 kA output. These anodes are passive sources of principally hydrocarbon and lithium beams. In applied-B ion diodes, passive ion sources use the applied voltage to produce the required ions either through an electron assisted desorption and surface flashover process, and/or through field emission mechanisms. Passive sources therefore require power delivered to the diode before ions will be turned-on. Passive sources provide a simple way to generate ions to test accelerator performance, accelerator to diode coupling, diagnostics, and to study sources of divergence and divergence reduction techniques. The authors will discuss the effect of magnetic field geometry and the important role of cathode feed electrons in the formation and evolution of the A-K gap electron sheath in the diode. Experimental data on diode operation and beam production will be compared to the predictions of PIC code simulations

  17. Stable radiation pressure acceleration of ions by suppressing transverse Rayleigh-Taylor instability with multiple Gaussian pulses

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, M. L.; Liu, B.; Hu, R. H.; Shou, Y. R.; Lin, C.; Lu, H. Y.; Lu, Y. R.; Ma, W. J., E-mail: wenjun.ma@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology, and Key Laboratory of HEDP of the Ministry of Education, CAPT, Peking University, Beijing 100871 (China); Gu, Y. Q. [Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Yan, X. Q., E-mail: x.yan@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology, and Key Laboratory of HEDP of the Ministry of Education, CAPT, Peking University, Beijing 100871 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006 (China)

    2016-08-15

    In the case of a thin plasma slab accelerated by the radiation pressure of an ultra-intense laser pulse, the development of Rayleigh-Taylor instability (RTI) will destroy the acceleration structure and terminate the acceleration process much sooner than theoretical limit. In this paper, a new scheme using multiple Gaussian pulses for ion acceleration in a radiation pressure acceleration regime is investigated with particle-in-cell simulation. We found that with multiple Gaussian pulses, the instability could be efficiently suppressed and the divergence of the ion bunch is greatly reduced, resulting in a longer acceleration time and much more collimated ion bunch with higher energy than using a single Gaussian pulse. An analytical model is developed to describe the suppression of RTI at the laser-plasma interface. The model shows that the suppression of RTI is due to the introduction of the long wavelength mode RTI by the multiple Gaussian pulses.

  18. Extraction of metals from liquid effluent using modified inorganic ion exchangers

    International Nuclear Information System (INIS)

    Hudson, M.J.

    1993-01-01

    Inorganic ion exchangers such as goethite, titanium (IV) oxide; silica and zeolites have been modified to examine the extraction of ruthenium; technetium and cobalt from liquid effluent. In addition, tin (IV) hydrogenphosphate and antimony hydrogenphosphate have been also examined in the modified and unmodified forms. It has been shown that some of the above reagents are able to remove the required metal ions from aqueous solution at the trace and mg L -1 levels. (author)

  19. Gas pressure of extractive system from the high power ion source and effect of compound materials on the optical characteristics of ion

    International Nuclear Information System (INIS)

    Pan Zudong; Chen Miaosun; Wang Shouhu; Chen Xingqin; Ge Yisan; Fu Peng

    1991-01-01

    The mechanism of extractive beam from the ion source and the ion optical condition of a minimal divergence angle were introduced briefly. Two problems in researching 15 cm Duo Penning Ion Source (extractive voltage-25 kV, current-20 A) are expounded: (1) The pulse admission way makes the extractive system keeping optimum vacuum; (2) The insulating rings are made of a compound material, therefore, insulating characteristic is improved. Both the described points (1) and (2) will make a contribution to the ion optics

  20. Studies on the Extraction Region of the Type VI RF Driven H- Ion Source

    Science.gov (United States)

    McNeely, P.; Bandyopadhyay, M.; Franzen, P.; Heinemann, B.; Hu, C.; Kraus, W.; Riedl, R.; Speth, E.; Wilhelm, R.

    2002-11-01

    IPP Garching has spent several years developing a RF driven H- ion source intended to be an alternative to the current ITER (International Thermonuclear Experimental Reactor) reference design ion source. A RF driven source offers a number of advantages to ITER in terms of reduced costs and maintenance requirements. Although the RF driven ion source has shown itself to be competitive with a standard arc filament ion source for positive ions many questions still remain on the physics behind the production of the H- ion beam extracted from the source. With the improvements that have been implemented to the BATMAN (Bavarian Test Machine for Negative Ions) facility over the last two years it is now possible to study both the extracted ion beam and the plasma in the vicinity of the extraction grid in greater detail. This paper will show the effect of changing the extraction and acceleration voltage on both the current and shape of the beam as measured on the calorimeter some 1.5 m downstream from the source. The extraction voltage required to operate in the plasma limit is 3 kV. The perveance optimum for the extraction system was determined to be 2.2 x 10-6 A/V3/2 and occurs at 2.7 kV extraction voltage. The horizontal and vertical beam half widths vary as a function of the extracted ion current and the horizontal half width is generally smaller than the vertical. The effect of reducing the co-extracted electron current via plasma grid biasing on the H- current extractable and the beam profile from the source is shown. It is possible in the case of a silver contaminated plasma to reduce the co-extracted electron current to 20% of the initial value by applying a bias of 12 V. In the case where argon is present in the plasma, biasing is observed to have minimal effect on the beam half width but in a pure hydrogen plasma the beam half width increases as the bias voltage increases. New Langmuir probe studies that have been carried out parallel to the plasma grid (in the

  1. Single Shot Measurements of the 4-Dimensional Transverse Phase Space Distribution of Intense Ion Beams at the UNILAC at GSI

    CERN Document Server

    Groening, L

    2003-01-01

    The UNILAC is used as an injector for the synchrotron SIS. It is designed to fill the synchrotron up to its space charge limit. The upper limit for the useful beam emittance of the UNILAC is given by the finite acceptance of the SIS during the injection process. In order to remain within this acceptance the emittance growth during beam acceleration and transportation due to space charge effects must be minimized by applying an appropriate beam focusing. Therefore, the influence of the magnetic focusing strength on the beam emittance growth was investigated experimentally for different beam currents. Measurements of transverse phase space distributions were performed before and after the Alvarez accelerator with a periodic focusing channel, respectively. In order to perform such a wide parameter scan within a reasonable time with respect to machine stability, the pepper pot technique was applied. The pepper pot method allows for single-pulse measurements. For comparison several measurements using the slit-grid...

  2. Experimental demonstration of ion extraction from magnetic thrust chamber for laser fusion rocket

    Science.gov (United States)

    Saito, Naoya; Yamamoto, Naoji; Morita, Taichi; Edamoto, Masafumi; Nakashima, Hideki; Fujioka, Shinsuke; Yogo, Akifumi; Nishimura, Hiroaki; Sunahara, Atsushi; Mori, Yoshitaka; Johzaki, Tomoyuki

    2018-05-01

    A magnetic thrust chamber is an important system of a laser fusion rocket, in which the plasma kinetic energy is converted into vehicle thrust by a magnetic field. To investigate the plasma extraction from the system, the ions in a plasma are diagnosed outside the system by charge collectors. The results clearly show that the ion extraction does not strongly depend on the magnetic field strength when the energy ratio of magnetic field to plasma is greater than 4.3, and the magnetic field pushes back the plasma to generate a thrust, as previously suggested by numerical simulation and experiments.

  3. The main mechanisms of flotation extraction of heavy metal ions out of water solutions

    International Nuclear Information System (INIS)

    Zubareva, G.I.

    2002-01-01

    Flotation extraction of heavy metal ions out of water solutions using reagent EMKO (sodium soaps of vat residues of C grade) is presented. It is established that it is related to hydration energy and stability of sublates being formed. These two parameters affect contrariwise. A difference of molar ratios [EMKO]:[Me] in the course of extracting metals into froth can be explained by their different aggregative state, and a proportion of ionic form of metals and hydroxides being formed. Metal flotation rate is different for each of metal cations to be floated and is dependant on hydrogen ion concentrations [ru

  4. The complex formation-partition and partition-association models of solvent extraction of ions

    International Nuclear Information System (INIS)

    Siekierski, S.

    1976-01-01

    Two models of the extraction process have been proposed. In the first model it is assumed that the partitioning neutral species is at first formed in the aqueous phase and then transferred into the organic phase. The second model is based on the assumption that equivalent amounts of cations are at first transferred from the aqueous into the organic phase and then associated to form a neutral molecule. The role of the solubility parameter in extraction and the relation between the solubility of liquid organic substances in water and the partition of complexes have been discussed. The extraction of simple complexes and complexes with organic ligands has been discussed using the first model. Partition coefficients have been calculated theoretically and compared with experimental values in some very simple cases. The extraction of ion pairs has been discussed using the partition-association model and the concept of single-ion partition coefficients. (author)

  5. System upgradation for surface mode negative ion beam extraction experiments in ROBIN

    International Nuclear Information System (INIS)

    Pandya, Kaushal; Bansal, Gourab; Soni, Jignesh

    2015-01-01

    ROBIN (Replica Of BATMAN source in India) is a replica of BATMAN source of IPP, Garching. Plasma production (inductively coupled, RF produced plasma), plasma diagnostic (langmuir probe, optical emission spectroscopy), negative ion beam extraction in volume mode with reduced extraction area of 2 cm 2 (4 apertures) using small bench top type power supply (10kV, 400mA), with increase extraction area of 73 cm 2 (146 apertures) and using actual power supplies (Extraction Power Supply System, EPSS (11kV, 35A), and Accelerator Power Supply System, APSS (35kV, 15A)) and beam diagnostic etc have been performed successfully in ROBIN. This paper will describe the details of the system upgradation for surface mode negative ion experiments and its performance in ROBIN

  6. QUANTITATIVE ION-PAIR EXTRACTION OF 4(5)-METHYLIMIDAZOLE FROM CARAMEL COLOR AND ITS DETERMINATION BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY

    DEFF Research Database (Denmark)

    Thomsen, Mohens; Willumsen, Dorthe

    1981-01-01

    A procedure for quantitative ion-pair extraction of 4(5)-methylimidazole from caramel colour using bis(2-ethylhexyl)phosphoric acid as ion-pairing agent has been developed. Furthermore, a reversed-phase ion-pair liquid chromatographic separation method has been established to analyse the content...

  7. Extraction of pulsed ion beams from an anode covered with liquid material

    International Nuclear Information System (INIS)

    Kitamura, Akira; Yano, Syukuro

    1982-01-01

    In order to extend the life of anodes of pulsed ion diodes, a trial was made to extract ions from a plasma created by surface flashover on the oil-covered anode. The diode with this anode worked well as a so-called pinched electron beam diode. Production of proton beams of 10 kA with energies of about 400 keV was confirmed by measurements with biased ion collectors and those of prompt γ-rays from the reaction 19 F(p,γα) 16 O. Substantial reduction of damage and substantial extension of the life of the anode disc were realized. (author)

  8. Computer simulation of 2-D and 3-D ion beam extraction and acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Ido, Shunji; Nakajima, Yuji [Saitama Univ., Urawa (Japan). Faculty of Engineering

    1997-03-01

    The two-dimensional code and the three-dimensional code have been developed to study the physical features of the ion beams in the extraction and acceleration stages. By using the two-dimensional code, the design of first electrode(plasma grid) is examined in regard to the beam divergence. In the computational studies by using the three-dimensional code, the axis-off model of ion beam is investigated. It is found that the deflection angle of ion beam is proportional to the gap displacement of the electrodes. (author)

  9. Extracting $p\\Lambda$ scattering lengths from heavy ion collisions

    CERN Document Server

    Shapoval, V M; Lednicky, R; Sinyukov, Yu M

    2015-01-01

    The $p-\\Lambda \\oplus \\bar{p}-\\bar{\\Lambda}$ and $\\bar{p}-\\Lambda \\oplus p-\\bar{\\Lambda}$ correlation functions for 10% most central Au+Au collisions at top RHIC energy $\\sqrt{s_{NN}}=200$ GeV are modeled with Lednicky and Lyuboshitz analytical formula using the source radii extracted from the hydrokinetic model (HKM) simulations. For the baryon-antibaryon case the corresponding spin-averaged strong interaction scattering length is obtained by fitting the STAR correlation function. In contrast to the experimental results, where extracted $p\\bar{\\Lambda}$ source radius value was found $\\sim 2$ times smaller than the corresponding $p\\Lambda$ one, the calculations in HKM show both $p\\Lambda$ and $p\\bar{\\Lambda}$ effective source radii to be quite close, as expected from theoretical considerations. To obtain the satisfactory fit to the measured baryon-antibaryon correlation function at this large source radius value, the modified analytical approximation to the correlation function, effectively accounting for the...

  10. Towards a realistic 3D simulation of the extraction region in ITER NBI relevant ion source

    International Nuclear Information System (INIS)

    Mochalskyy, S.; Wünderlich, D.; Fantz, U.; Franzen, P.; Minea, T.

    2015-01-01

    The development of negative ion (NI) sources for ITER is strongly accompanied by modelling activities. The ONIX code addresses the physics of formation and extraction of negative hydrogen ions at caesiated sources as well as the amount of co-extracted electrons. In order to be closer to the experimental conditions the code has been improved. It includes now the bias potential applied to first grid (plasma grid) of the extraction system, and the presence of Cs + ions in the plasma. The simulation results show that such aspects play an important role for the formation of an ion–ion plasma in the boundary region by reducing the depth of the negative potential well in vicinity to the plasma grid that limits the extraction of the NIs produced at the Cs covered plasma grid surface. The influence of the initial temperature of the surface produced NI and its emission rate on the NI density in the bulk plasma that in turn affects the beam formation region was analysed. The formation of the plasma meniscus, the boundary between the plasma and the beam, was investigated for the extraction potentials of 5 and 10 kV. At the smaller extraction potential the meniscus moves closer to the plasma grid but as in the case of 10 kV the deepest meniscus bend point is still outside of the aperture. Finally, a plasma containing the same amount of NI and electrons (n H − =n e =10 17 m −3 ), representing good source conditioning, was simulated. It is shown that at such conditions the extracted NI current can reach values of ∼32 mA cm −2 using ITER-relevant extraction potential of 10 kV and ∼19 mA cm −2 at 5 kV. These results are in good agreement with experimental measurements performed at the small scale ITER prototype source at the test facility BATMAN. (paper)

  11. Extraction design and low energy beam transport optimization of space charge dominated multispecies ion beam sources

    International Nuclear Information System (INIS)

    Delferriere, O.; De Menezes, D.

    2004-01-01

    In all accelerator projects, the low energy part of the accelerator has to be carefully optimized to match the beam characteristic requirements of the higher energy parts. Since 1994 with the beginning of the Injector of Protons for High Intensity (IPHI) project and Source of Light Ions with High Intensities (SILHI) electron cyclotron resonance (ECR) ion source development at CEA/Saclay, we are using a set of two-dimensional (2D) codes for extraction system optimization (AXCEL, OPERA-2D) and beam transport (MULTIPART). The 95 keV SILHI extraction system optimization has largely increased the extracted current, and improved the beam line transmission. From these good results, a 130 mA D + extraction system for the International Fusion Material Irradiation Facility project has been designed in the same way as SILHI one. We are also now involved in the SPIRAL 2 project for the building of a 40 keV D + ECR ion source, continuously tunable from 0.1 to 5 mA, for which a special four-electrode extraction system has been studied. In this article we will describe the 2D design process and present the different extraction geometries and beam characteristics. Simulation results of SILHI H + beam emittance will be compared with experimental measurements

  12. Synergistic Effect of Azadirachta Indica Extract and Iodide Ions on the Corrosion Inhibition of Aluminium in Acid Media

    Energy Technology Data Exchange (ETDEWEB)

    Arab, S. T.; Al- Turkustani, A. M.; Al- Dhahiri, R. H. [King Abd El- Aziz University, Jeddah (Saudi Arabia)

    2008-06-15

    The synergistic action caused by iodide ions on the corrosion inhibition of aluminium (Al) in 0.5 M HCl in the presence of Azadirachta Indica (AZI) plant extract has been investigated using potintiodynamic polarization and impedance techniques. It is found that AZI extract inhibits the corrosion of aluminium in 0.5 M HCl. The inhibition efficiency increases with the increase in AZI extract concentration, until 24% v/v of AZI extract, then Inh.% is decreased with father increase in AZI extract concentration. The adsorption of this extract in the studied concentration is found to obey Frewendlish adsorption isotherm. The addition of iodide ions enhances the inhibition efficiency to a considerable extent. The increase in Inh.% values in presence of fixed concentration of iodide ions indicates that AZI extract forms an insoluble complex at lower AZI extract concentrations by undergoing a joint adsorption. But at higher concentrations of AZI extract, competitive adsorption is found between iodide ions and the formed complex leading to less Inh.%. The Inh.% decreased in presence of iodide ions with AZI extract than in presence of AZI extract alone at all studied iodide concentrations. The synergism parameter S {sub θ} is defined and calculated from surface coverage values. This parameter in the case of AZI extract is found to be more than unity, indicating that the enhanced inhibition efficiency caused by the addition of iodide ions.

  13. Development of ion imprinted polymers for the selective extraction of lanthanides from environmental samples

    International Nuclear Information System (INIS)

    Moussa, Manel

    2016-01-01

    The analysis of the lanthanide ions present at trace level in complex environmental matrices requires often a purification and preconcentration step. The solid phase extraction (SPE) is the most used sample preparation technique. To improve the selectivity of this step, Ion Imprinted Polymers (IIPs) can be used as SPE solid supports. The aim of this work was the development of IIPs for the selective extraction of lanthanide ions from environmental samples. In a first part, IIPs were prepared according to the trapping approach using 5,7-dichloroquinoline-8-ol as non-vinylated ligand. For the first time, the loss of the trapped ligand during template ion removal and sedimentation steps was demonstrated by HPLC-UV. Moreover, this loss was not repeatable, which led to a lack of repeatability of the SPE profiles. It was then demonstrated that the trapping approach is not appropriate for the IIPs synthesis. In a second part, IIPs were synthesized by chemical immobilization of methacrylic acid as vinylated monomer. The repeatability of the synthesis and the SPE protocol were confirmed. A good selectivity of the IIPs for all the lanthanide ions was obtained. IIPs were successfully used to selectively extract lanthanide ions from tap and river water. Finally, IIPs were synthesized by chemical immobilization of methacrylic acid and 4-vinylpyridine as functional monomers and either a light (Nd 3+ ) or a heavy (Er 3+ ) lanthanide ion as template. Both kinds of IIPs led to a similar selectivity for all lanthanide ions. Nevertheless, this selectivity can be modified by changing the nature and the pH of the washing solution used in the SPE protocol. (author)

  14. Evaluation of Ion Exchange Materials in K Basin Floor Sludge and Potential Solvents for PCB Extraction from Ion Exchange Materials

    International Nuclear Information System (INIS)

    Schmidt, A.J.; Klinger, G.S.; Bredt, P.R.

    1998-01-01

    Approximately 73 m 3 of heterogeneous solid material, ''sludge,'' (upper bound estimate, Packer 1997) have accumulated at the bottom of the K Basins in the 100 K Area of the Hanford Site. This sludge is a mixture of spent fuel element corrosion products, ion exchange materials (organic and inorganic), graphite-based gasket materials, iron and aluminum metal corrosion products, sand, and debris (Makenas et al. 1996, 1997). In addition, small amounts of polychlorinated biphenyls (PCBs) have been found. These small amounts are significant from a regulatory standpoint. Ultimately, it is planned to transfer the K Basins sludge to the Hanford double shell tanks (DSTs). Chemical pretreatment is required to address criticality issues and the destruction or removal of PCBs before the K Basin sludge can be transferred to the DSTs. Eleven technologies have been evaluated (Papp 1997) as potential pretreatment methods. Based on the evaluations and engineering studies and limited testing, Fluor Daniel Hanford recommended solvent washing of the K Basin sludge, followed by nitric acid dissolution and, potentially, peroxide addition (FDH 1997). The solvent washing (extraction) and peroxide addition would be used to facilitate PCB removal and destruction. Following solvent extraction, the PCBs could be distilled and concentrated for disposal as a low-level waste. The purpose of the work reported here was to continue investigating solvent extraction, first by better identifying the ion exchange materials in the actual sludge samples and then evaluating various solvents for removing the PCBs or possibly dissolving the resins. This report documents some of the process knowledge on ion exchange materials used and spilled in the K Basins and describes the materials identified from wet sieving KE Basin floor and canister sludge and the results of other analyses. Several photographs are included to compare materials and illustrate material behavior. A summary of previous tests on solvent

  15. Stream mesocosm response sensitivities to simulated ion stress in produced waters from resource extraction activities

    Science.gov (United States)

    To increase the ecological relevance of laboratory exposures intent on determining species sensitivity to ion stress from resource extraction activities we have conducted several stream mesocosm dosing studies that pair single-species and community-level responses in-situ and all...

  16. Benzene-centered tripodal diglycolamides : Synthesis, metal ion extraction, luminescence spectroscopy, and DFT studies

    NARCIS (Netherlands)

    Leoncini, Andrea; Ansari, Seraj Ahmad; Mohapatra, Prasanta Kumar; Boda, Anil; Musharaf Ali, Sheikh; Sengupta, Arijit; Huskens, Jurriaan; Verboom, Willem

    2017-01-01

    Three benzene-centered tripodal diglycolamides (Bz-T-DGAs) were synthesized and evaluated for actinide, lanthanide, and fission product ion extraction. 1,3,5-Triethylbenzene-based tripodal DGA (LI) showed high distribution ratio (D) values for Am3+ and Eu3+ in a mixture of 95% n-dodecane and 5%

  17. Performance limits of ion extraction systems with non-circular apertures

    Energy Technology Data Exchange (ETDEWEB)

    Shagayda, A., E-mail: shagayda@gmail.com; Madeev, S. [Keldysh Research Centre, Onezhskaya, 8, 125438 Moscow (Russian Federation)

    2016-04-15

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  18. Performance limits of ion extraction systems with non-circular apertures.

    Science.gov (United States)

    Shagayda, A; Madeev, S

    2016-04-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  19. Performance limits of ion extraction systems with non-circular apertures

    Science.gov (United States)

    Shagayda, A.; Madeev, S.

    2016-04-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  20. Performance limits of ion extraction systems with non-circular apertures

    International Nuclear Information System (INIS)

    Shagayda, A.; Madeev, S.

    2016-01-01

    A three-dimensional computer simulation is used to determine the perveance limitations of ion extraction systems with non-circular apertures. The objective of the study is to analyze the possibilities to improve mechanical strength of the ion optics made of carbon-carbon composite materials. Non-circular grid apertures are better suited to the physical structure of carbon-carbon composite materials, than conventionally used circular holes in a hexagonal pattern, because they allow a fewer number of cut fibers. However, the slit-type accelerating systems, usually regarded as the main alternative to the conventional ion optics, have an intolerably narrow range of operating perveance values at which there is no direct ion impingement on the acceleration grid. This paper presents results of comparative analysis of a number of different ion optical systems with non-circular apertures and conventional ion optical systems with circular apertures. It has been revealed that a relatively wide perveance range without direct ion impingement may be obtained with apertures shaped as a square with rounded corners. Numerical simulations show that this geometry may have equivalent perveance range as the traditional geometry with circular apertures while being more mechanically robust. In addition, such important characteristics, as the effective transparency for both the ions and the neutral atoms, the height of the potential barrier reflecting the downstream plasma electrons and the angular divergence of the beamlet also can be very close to these parameters for the optics with circular apertures.

  1. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems; Banco de pruebas portatil para el estudio de fuentes de iones y de la extraccion y enfoque del haz de iones

    Energy Technology Data Exchange (ETDEWEB)

    Cordero Lopez, F

    1961-07-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  2. Observing dynamics of chromatin fibers in Xenopus egg extracts by single DNA manipulation using a transverse magnetic tweezer setup

    Science.gov (United States)

    Yan, Jie; Skoko, Dunja; Marko, John; Maresca, Tom; Heald, Rebecca

    2005-03-01

    We have studied assembly of chromatin on single DNAs using Xenopus egg extracts and a specially designed magnetic tweezer setup which generates controlled force in the focal plane of the objective, allowing us to visualize and measure DNA extension under a wide range of constant tensions. We found, in the absence of ATP, interphase extracts assembled nucleosomes against DNA tensions of up to 3.5 piconewtons (pN). We observed force-induced disassembly and opening-closing fluctuations indicating our experiments were in mechano-chemical equilibrium. We found that the ATP-depleted reaction can do mechanical work of 27 kcal/mol per nucleosome, providing a measurement of the free energy difference between core histone octamers on and off DNA. Addition of ATP leads to highly dynamic behavior: time courses show processive runs of assembly and disassembly of not observed in the -ATP case, with forces of 2 pN leading to nearly complete fiber disassembly. Our study shows that ATP hydrolysis plays a major role in nucleosome rearrangement and removal, and suggests that chromatin in vivo may be subject to continual assembly and disassembly.

  3. Analysis for extraction and bunching of ion beam from spherical reflex triode

    International Nuclear Information System (INIS)

    Kawata, Shigeo; Abe, Takashi; Kasuya, Koichi; Niu, Keishiro.

    1978-11-01

    Since an ion beam is hoped to impinge on a target in a spherically symmetric way for inertial confinement fusion, an analysis is developed here for the intense ion beam which is extracted from a spherical reflex triode. The basic equations are the Poisson equation for the electric potential and the conservation equations of energies for the ion and electron velocities. According to the asymptotic solution, the extracted ion-beam-current density is proportional to the power of 3/2 of the voltage imposed on the triode. This dependence of the current density on the voltage is improved to be the power of 1.6 by the numerical analysis. A special time-dependence of the ion-beam power at the target surface is required for an optimal implosion of the target. Using the bunching theory for the ion beam, we derive numerically an optimal time-dependence of the voltage imposed on the triode. Asymptotic forms are also obtained analytically for the voltage. (author)

  4. Evaluation of a novel task specific ionic liquid for actinide ion extraction

    International Nuclear Information System (INIS)

    Paramanik, M.; Ghosh, S.K.; Raut, D.R.; Mohapatra, P.K.

    2016-01-01

    Separation of U and Pu from nuclear waste is of great relevance for a sustainable closed fuel cycle point of view. Spent fuel reprocessing by the well known PUREX process is done world wide for the recovery of U and Pu using TBP as the extractant. Room temperature ionic liquids (RTILs) have shown significantly higher extraction of metal ions, particularly at lower acidity as compared to the molecular diluents. Functionalization of ionic liquids has resulted in highly efficient task specific ionic liquids (TSILs) with superior extraction properties than the analogous extractants dissolved in ionic liquids. The present paper reports the evaluation of a novel task specific ionic liquid (TSIL) containing >P=O functional group for the extraction of actinides like U(VI) and Pu(IV)

  5. Extraction of lithium ion from alkaline aqueous media by a liquid surfactant membrane

    International Nuclear Information System (INIS)

    Kinugasa, Takumi; Ono, Yuri; Kawamura, Yuko; Watanabe, Kunio; Takeuchi, Hiroshi.

    1995-01-01

    Extraction of lithium ion from aqueous alkaline media by a liquid surfactant membrane was performed using a mixture of LIX54 and TOPO as the extractant. Stripping of lithium from the kerosene solution to the acid solution was suppressed with increasing content of polyamine (ECA) surfactant. The extraction rate of lithium by the liquid membrane could be interpreted taking account of an interfacial resistance due to ECA. It was confirmed that swelling of the (W/O) emulsion drops by water permeation through the liquid membrane is evaluated in terms of a change in osmotic pressure gradient between the external and internal aqueous phases during the lithium extraction. In the present operation, the extraction ratio of Li + from the external feed and the uptake into the internal phase reached as high as 95%. (author)

  6. Ion-pair extraction of [3H]stobadine from biological fluids

    International Nuclear Information System (INIS)

    Scasnar, V.

    1998-01-01

    A simple and specific radiometric assay was developed for the determination of stobadine, a cardioprotective drug, in the serum of experimental animals. The assay is based on a single extraction step of the radioactively labeled drug from serum into the benzene solution of dicarbolide of cobalt followed by quantitation of the extracted radioactivity by using liquid scintillation counting. The extraction mechanism involves the ion-pair formation between the protonized molecule of stobadine and the hydrophobic, negatively charged molecule of dicarbolide of cobalt. The extraction yield of stobadine from 1 ml of serum was 95% in the concentration range from 1 to 6000 ng/ml. The co-extraction of metabolites was less than 5%. The method was applied to the determination of stobadine in serum of dogs and the data obtained were in a good agreement with those obtained by high performance liquid chromatography. (author)

  7. Selective chelation-supercritical fluid extraction of metal ions from waste materials

    International Nuclear Information System (INIS)

    Wai, C.N.; Laintz, K.E.; Yonker, C.R.

    1993-01-01

    The removal of toxic organics, metals, and radioisotopes from solids or liquids is a major concern in the treatment of industrial and nuclear wastes. For this reason, developing methods for selective separation of toxic metals and radioactive materials from solutions of complex matrix is an important problem in environmental research. Recent developments indicate supercritical fluids are good solvents for organic compounds. Many gases become supercritical fluids under moderate temperatures and pressures. For example, the critical temperature and pressure of carbon dioxide are 31 degrees C and 73 atm, respectively. The high diffusivity, low viscosity, and T-P dependence of solvent strength are some attractive properties of supercritical fluid extraction (SFE). Since CO 2 offers the additional benefits of stability and non-toxicity, the SFE technique avoids generation of organic liquid waste and exposure of personnel to toxic solvents. While direct extraction of metal ions by supercritical fluids is highly inefficient, these ions when complexed with organic ligands become quite soluble in supercritical fluids. Specific ligands can be used to achieve selective extraction of metal ions in this process. After SFE, the fluid phase can be depressurized for precipitation of the metal chelates and recycled. The ligand can also be regenerated for repeated use. The success of this selective chelation-supercritical fluid extraction (SC-SFE) process depends on a number of factors including the efficiencies of the selective chelating agents, solubilities of metal chelates in supercritical fluids, rate of extraction, ease of regeneration of the ligands, etc. In this report, the authors present recent results on the studies of the solubilities of metal chelates in supercritical CO 2 , experimental ions from aqueous solution, and the development of selective chelating agents (ionizable crown ethers) for the extraction of lanthanides and actinides

  8. Synthesis, characterization and application of ion imprinted poly(vinylimidazole for zinc ion extraction/preconcentration with faas determination

    Directory of Open Access Journals (Sweden)

    Queila O. dos Santos

    2014-01-01

    Full Text Available In this paper, we describe the synthesis of an ion imprinted polymer (IIP by homogeneous polymerization and its use in solid-phase to extract and preconcentrate zinc ions. Under optimal conditions (pH 5.0, preconcentration flow rate of 12.0 mL min-1, and eluted with 1.0 mol L-1 HNO3 this procedure allows the determination of zinc with an enrichment factor of 10.2, and with limits of detection and quantification of 1.5 and 5.0 µg L-1, respectively. The accuracy of our results was confirmed by analysis of tap water and certified reference materials: NIST 1570a (Spinach leaves and NIST 1515 (Apple leaves.

  9. Anode plasma dynamics in an extraction applied-B ion diode: effects on divergence, ion species and parasitic load

    International Nuclear Information System (INIS)

    Greenly, J.B.; Appartaim, R.K.; Olson, J.C.

    1996-01-01

    Analysis of data from the LION (1.2 MV, 300 kA, 40 ns) extraction applied-B diode allows a number of inferences regarding the effect of anode plasma dynamics on ion beam divergence, ion species composition, and diode impedance and power coupling. The two dominant features of anode plasma dynamics observed on LION are (1) plasma expansion away from the solid anode surface and into the accelerating gap during the beam pulse, and (2) evolution of the composition of the plasma during the pulse. The data presented in this paper characterize the plasma expansion, and suggest a possible picture of the mechanism of the plasma dynamics that could produce these basic features. (J.U.). 2 figs., 5 refs

  10. Anode plasma dynamics in an extraction applied-B ion diode: effects on divergence, ion species and parasitic load

    Energy Technology Data Exchange (ETDEWEB)

    Greenly, J B; Appartaim, R K; Olson, J C [Cornell Univ., Ithaca, NY (United States). Lab. of Plasma Studies

    1997-12-31

    Analysis of data from the LION (1.2 MV, 300 kA, 40 ns) extraction applied-B diode allows a number of inferences regarding the effect of anode plasma dynamics on ion beam divergence, ion species composition, and diode impedance and power coupling. The two dominant features of anode plasma dynamics observed on LION are (1) plasma expansion away from the solid anode surface and into the accelerating gap during the beam pulse, and (2) evolution of the composition of the plasma during the pulse. The data presented in this paper characterize the plasma expansion, and suggest a possible picture of the mechanism of the plasma dynamics that could produce these basic features. (J.U.). 2 figs., 5 refs.

  11. Application of the code Slac to the study of Ion Extraction Systems in Neutral Injectors

    International Nuclear Information System (INIS)

    Garcia, M.; Liniers, M.; Guasp, J.

    1997-01-01

    In this study different extraction geometries for intense ion beams have been analyzed with the code SLAC, in view of its possible application to the neutral injectors of TJ-II. With this aim, we have introduced several modifications in the code in order to correctly simulate the transition between the ion source plasma and the extraction region, which has great impact on the beam optics. These modifications include the introduction of a population of Boltzmann electrons in the transition region, and the implementation of an option to simulate the thermal velocity of the ions in the source. We have found a better agreement between the results obtained with the new version of the code and the experimental data in two well known systems. With this new version of the code two different studies have been carried out: in the first place an optimization of the ATF injectors extraction system for its use on TJ-II, leading to an optimum value of the gap in the energy range 30-40 KeV, and in the second place a systematic study of extraction geometries at 40 KeV. As a result of this second study we have found the combinations of parameters that can be used under different working conditions (e.g. different pulse lengths), leading to acceptable values of the beam divergence. (Author)

  12. Causes and cures for errors in the simulation of ion extraction from plasmas

    International Nuclear Information System (INIS)

    Becker, R.

    2006-01-01

    For many years, computer programs have been available to simulate the extraction of positive ions from plasmas. The results of such simulations may not always agree with measurements. There are different reasons for this: the mathematical formulation must match with the simulated physics, the number of meshes must be high enough to correctly take into account the nonlinear space charge in the sheath, and ray tracing must be done in sufficiently small steps, using numerically correct field components and partial derivatives. In addition to these hidden problems the user may create errors by a wrong choice of parameters, which are not matching the assumptions of the mathematical formulation. Examples are the use of a positive ion extraction program for the extraction of negative ones, the choice of a wrong angle between the plasma electrode and the beam boundary in the vicinity of the meniscus, and the use of too few trajectories. The design of extraction electrodes generally has the aim to optimize the optical properties and the current of the ion beam. However, it is also important to take into account the surface fields in order to avoid dark currents and sparking

  13. Extraction mechanism of U(VI) ions by N,N-dialkylamides

    International Nuclear Information System (INIS)

    Descouls, N.; Musikas, C.

    1985-09-01

    N,N dialkylamides are good extractants of UO 2 2+ ions from the nitric solutions obtained on dissolution of nuclear irradiated fuels. The extraction mechanism of U(VI) ions proved to be rather complex. Two species were identified by spectrophotometry in the organic phase: UO 2 (NO 3 ) 2 L 2 (1) and UO 2 (NO 3 ) 3 HL (2), L standing for the amide molecule. The complex (1) is typical for neutral molecules extractants. However, when log D(U(VI)) is plotted against log C (amide), the slope of the straight line obtained is greater than 2, which suggests that amide (1) interactions take place in the 2sup(nd) coordination sphere of U(VI) ions. The crystal structure of (1) where L is the N,N-di-n-butyldodecanamide show that Van der Waals interactions occur between the dodecyl chains of two (1) molecules. The complex (2) is characteristic for anionic extractants. For the amide molecules studied, it takes place in very acidic media. In order to investigate the nature of the UO 2 (NO 3 ) 3 HL complex, the infra-red shift of νc=0 vibration were compared in the following compounds: free amide, HNO 3 - L, phenol L, UO 2 (NO 3 ) 3 HL. The results are discussed. 14 refs [fr

  14. Improved Light Extraction Efficiency by Photonic Crystal Arrays on Transparent Contact Layer Using Focused Ion Beams

    International Nuclear Information System (INIS)

    Wu, G.M.; Tsai, B.H.; Kung, S.F.; Wu, C.F.

    2011-01-01

    Nitride-based thin-film materials have become increasingly important for the high brightness light-emitting diode applications. The improvements in light extraction and lower power consumption are highly desired. Although the internal quantum efficiency of GaN-based LED has been relatively high, only a small fraction of light can be extracted. In this study, a new design of two-dimensional photonic crystal array has been prepared on the top transparent contact layer of indium-tin oxide film to improve the light extraction efficiency using focused ion beam. The acceleration voltage of the Ga dual-beam nanotechnology system SMI 3050 was 30 kV and the ion beam current was 100 pA. The cylindrical air holes had the diameter of 150 nm and depth of 100 nm. The micro photoluminescence analysis results showed that the light output intensity could be 1.5 times of that of the non-patterned control sample. In addition, the structural damage from the focused ion beam drilling of GaN step could be eliminated. The excellent I-V characteristics have been maintained, and the external light extraction efficiency would be still improved for the LED devices. (author)

  15. Low-energy ion beam extraction and transport: Experiment--computer comparison

    International Nuclear Information System (INIS)

    Spaedtke, P.; Brown, I.; Fojas, P.

    1994-01-01

    Ion beam formation at low energy (∼1 keV or so) is more difficult to accomplish than at high energy because of beam blowup by space-charge forces in the uncompensated region within the extractor, an effect which is yet more pronounced for heavy ions and for high beam current density. For the same reasons, the extracted ion beam is more strongly subject to space charge blowup than higher energy beams if it is not space-charge neutralized to a high degree. A version of vacuum arc ion source with an extractor that produces low-energy metal ion beams at relatively high current (∼0.5--10 kV at up to ∼100 mA) using a multi-aperture, accel--decel extractor configuration has been created. The experimentally observed beam extraction characteristics of this source is compared with those predicted using the AXCEL-INP code, and the implied downstream beam transport with theoretical expectations. It is concluded that the low-energy extractor performance is in reasonable agreement with the code, and that good downstream space charge neutralization is obtained. Here, the code and the experimental results are described, and the features that contribute to good low-energy performance are discussed

  16. Satellite Lithium-Ion Battery Remaining Cycle Life Prediction with Novel Indirect Health Indicator Extraction

    Directory of Open Access Journals (Sweden)

    Haitao Liao

    2013-07-01

    Full Text Available Prognostics and remaining useful life (RUL estimation for lithium-ion batteries play an important role in intelligent battery management systems (BMS. The capacity is often used as the fade indicator for estimating the remaining cycle life of a lithium-ion battery. For spacecraft requiring high reliability and long lifetime, in-orbit RUL estimation and reliability verification on ground should be carefully addressed. However, it is quite challenging to monitor and estimate the capacity of a lithium-ion battery on-line in satellite applications. In this work, a novel health indicator (HI is extracted from the operating parameters of a lithium-ion battery to quantify battery degradation. Moreover, the Grey Correlation Analysis (GCA is utilized to evaluate the similarities between the extracted HI and the battery’s capacity. The result illustrates the effectiveness of using this new HI for fading indication. Furthermore, we propose an optimized ensemble monotonic echo state networks (En_MONESN algorithm, in which the monotonic constraint is introduced to improve the adaptivity of degradation trend estimation, and ensemble learning is integrated to achieve high stability and precision of RUL prediction. Experiments with actual testing data show the efficiency of our proposed method in RUL estimation and degradation modeling for the satellite lithium-ion battery application.

  17. Effect of high ionic strength on the extraction of uranium(VI ions

    Directory of Open Access Journals (Sweden)

    M.K. Nazal

    2014-01-01

    Full Text Available Preparation and characterization of didodecylphosphoric acid (HDDPA as an extractant in toluene was carried. Mass spectroscopy showed that the monomer peak at 457.4 amu [M–Na+] is double that of the dimer at 891.9 amu [M–M–Na+] and the monomer molecules concentration dominate the dimer molecules in toluene. HDDPA was used as an extractant for the extraction of U(VI ion from perchlorate and nitrate media that have ionic strength (1.00, 3.00, 5.00, 7.00 M. The effect of HDDPA concentration, pcH, ionic strength of supporting electrolytes, and temperature in the range 15–45 °C on the extraction process have been studied. The stoichiometry of the extraction of U(VI ion, the free energy change (ΔG, the enthalpy change (ΔH, the entropy change (ΔS, and Kex at different ionic strength have been calculated. The formula of the complexes, which were formed has been established to be UO2(X(R2(HR2 at pcH equal 2.00 and UO2(X(R2(HR2 and UO2(X(R2 at pcH = 1.00, where (X isClO4- orNO3- and (HR2 is didodecylphosphoric acid monomer, (R2 is the deprotonated didodecylphosphoric acid, where R is the dodecyl group.

  18. Dialkyldithiophosphoric acids - chemical properties and 5f and 4f elements ions extraction

    International Nuclear Information System (INIS)

    Pattee, D.

    1987-09-01

    This work is a contribution to the study of the properties of the dialkyldithiophosphoric acids and of the extraction of the 4f and 5f ions from weakly acidic nitrate and phosphate media. Following a complete bibliographic study, synthesis and purification of the di-2-ethylhexyl-dithiophosphoric acid (HDEHDTP) is studied. It is identified with chemical methods and spectroscopic methods (I.R., N.M.R., V.P.C.); its by products, the di-2-ethylhexyl (monothio) phosphoric acids (HDEHTP, HDEHP) are also identified and characterized. Stability against hydrolysis and radiolysis is determined. The extractive properties are studied for the 4f and 5f ions. The presence of a sulfur donor atom in HDEHDTP makes it inefficient for the extraction of trivalent lanthanides and actinides but brings out a certain selectivity for americium. For HDEHTP, the presence of an oxygen donor atom rubs out any selectivity and the extraction constants are greater. Selectivity of HDEHDTP is increased by TBP (tri-n-butylphosphate) in synergistic mixtures. The mechanism of extraction of hexavalent uranium from phosphoric medium is elucidated. A model is developed by NMR for the micellisation of the sodium salts of HDEHDTP, HDEHTP and HDEHP, and extrapolated it to the trivalent rare earth salts of the acids. The structures are verified by light scattering and low angle X-ray diffraction [fr

  19. Solvent extraction of some metal ions by dithiocarbamate types of chemically modified lipophilic chitosan

    International Nuclear Information System (INIS)

    Inoue, K.; Nakagawa, H.; Naganawa, H.; Tachimori, S.

    2001-01-01

    Chitosan is a basic polysaccharide containing primary amino groups with high reactivity. we prepared O,O'-decanoyl chitosan and dithiocarbamate O,O'-decanoyl chitosan; the former was soluble in chloroform and toluene, while latter was soluble not only these diluents but also in some aliphatic diluents such as hexane and kerosene which are employed in commercial scale solvent extraction. Solvent extraction by dithiocarbamate O,O'-decanoyl chitosan in kerosene was tested for some base metal ions from sulfuric acid solution. The sequence of selectivity for these metal ions was found to be as follows: Cu(II) >> Ni(II) > Cd(II) ∼ Fe(III) > Co(II) ∼ Zn(II). Copper(II) was quantitatively extracted at pH > 1 and quantitatively stripped with 2 M sulfuric acid solution. Solvent extraction of silver(I) and gold(III) from hydrochloric acid as well as lanthanides and americium(III) from nitrate solution were also tested. Americium was selectively extracted over trivalent lanthanides, suggesting a high possibility for the final treatment of high level radioactive wastes. (authors)

  20. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Küchler, D

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  1. The removal of uranium from acidic media using ion exchange and/or extraction chromatography

    International Nuclear Information System (INIS)

    FitzPatrick, J.R.; Schake, B.S.; Murphy, J.; Holmes, K.; West, M.H.

    1996-06-01

    The separation and purification of uranium from either nitric acid or hydrochloric acid media can be accomplished by using either solvent extraction or ion-exchange. Over the past two years at Los Alamos, emerging programs are focused on recapturing the expertise required to do limited, small-quantity processing of enriched uranium. During this period of time, we have been investigating ion-addition, waste stream polishing is associated with this effort in order to achieve more complete removal of uranium prior to recycle of the acid. Extraction chromatography has been demonstrated to further polish the uranium from both nitric and hydrochloric acid media thus allowing for a more complete recovery of the actinide material and creation of less waste during the processing steps

  2. Event Patterns Extracted from Transverse Momentum and Rapidity Spectra of Z Bosons and Quarkonium States Produced in pp and Pb-Pb Collisions at LHC

    Directory of Open Access Journals (Sweden)

    Ya-Hui Chen

    2016-01-01

    Full Text Available Transverse momentum (pT and rapidity (y spectra of Z bosons and quarkonium states (some charmonium cc¯ mesons such as J/ψ and ψ(2S and some bottomonium bb¯ mesons such as Υ(1S, Υ(2S, and Υ(3S produced in proton-proton (pp and lead-lead (Pb-Pb collisions at the large hadron collider (LHC are uniformly described by a hybrid model of two-component Erlang distribution for pT spectrum and two-component Gaussian distribution for y spectrum. The former distribution results from a multisource thermal model, and the latter one results from the revised Landau hydrodynamic model. The modelling results are in agreement with the experimental data measured in pp collisions at center-of-mass energies s=2.76 and 7 TeV and in Pb-Pb collisions at center-of-mass energy per nucleon pair sNN=2.76 TeV. Based on the parameter values extracted from pT and y spectra, the event patterns (particle scatter plots in two-dimensional pT-y space and in three-dimensional velocity space are obtained.

  3. Extraction of high-intensity ion beams from a laser plasma by a pulsed spherical diode

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Oguri

    2005-06-01

    Full Text Available High-current Cu^{+} ion beams were extracted from a laser-produced plasma using a pulsed high-voltage multiaperture diode driven by an induction cavity. The amplitude and the duration of the extraction voltage were 130 kV and 450 ns, respectively. During the extraction, explosive beam divergence due to the strong space-charge force was suppressed by the focusing action of the gap between concentric hemispheres. Modulation of the extracted beam flux due to the plasma prefill in the gap has been eliminated by using a biased control grid put on the anode holes. By means of this extraction scheme we obtained a rectangular beam pulse with a rise time as short as ≈100  ns. The beam current behind the cathode was limited to ≈0.1   A, owing to space-charge effects, as well as to poor geometrical transmission through the cathode sphere. From the measurement of the extracted beam current density distribution along the beam axis and the beam profile measurement, we found a beam waist slightly downstream of the spherical center of the diode structure. The measured beam behavior was consistent with numerical results obtained via a 3D particle code. No serious degradation of the beam emittance was observed for the grid-controlled extraction scheme.

  4. Uniform current density and divergence control in high power extraction ion diodes

    International Nuclear Information System (INIS)

    Desjarlais, M.P.; Coats, R.S.; Lockner, T.R.; Pointon, T.D.; Johnson, D.J.; Slutz, S.A.; Lemke, R.W.; Cuneo, M.E.; Mehlhorn, T.A.

    1996-01-01

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one-dimensional analysis of the diamagnetic compression of magnetic streamlines and the self-consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one-dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments. (author). 8 figs., 15 refs

  5. Uniform current density and divergence control in high power extraction ion diodes

    International Nuclear Information System (INIS)

    Desjarlais, M.P.; Coats, R.S.; Lockner, T.R.; Pointon, T.D.; Johnson, D.J.; Slutz, S.A.; Lemke, R.W.; Cuneo, M.E.; Melhorn, T.A.

    1996-01-01

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one dimensional analysis of the diamagnetic compression of magnetic streamlines and the self consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments

  6. Theory of mass-discrimination effects in ion extraction from a plasma of wide pressure range

    International Nuclear Information System (INIS)

    Chang, J.-S.; Kodera, K.

    1979-01-01

    Mass-discrimination effects in stagnation-point ion extraction are treated for a plasma with a wide range of Knudsen number, i.e. when the charged particle's mean free path 3 , ion Schmidt numbers, from 0 to 10 4 , the effective Knudsen number K from 0 to infinity, and the Debye ratio Rsub(p)/lambdasub(D) from 0 to 10 -1 . Numerical results show that: (1) for a non-flowing plasma, mass-discrimination effects increase with increasing effective Knudsen number (or gas pressure) and decreasing sampling potential; (2) for a non-flowing plasma, no significant effect of the Debye ratio on mass-discrimination was found; (3) for a flowing plasma, mass-discrimination effects decrease with increasing Reynolds number (or flow velocity) and ion Schmidt number, and with decreasing sampling potential and effective Knudsen number. (Auth.)

  7. Uniform current density and divergence control in high power extraction ion diodes

    Energy Technology Data Exchange (ETDEWEB)

    Desjarlais, M P; Coats, R S; Lockner, T R; Pointon, T D; Johnson, D J; Slutz, S A; Lemke, R W; Cuneo, M E; Mehlhorn, T A [Sandia Labs., Albuquerque, NM (United States)

    1997-12-31

    A theory of radial beam uniformity in extraction ion diodes is presented. The theory is based on a locally one-dimensional analysis of the diamagnetic compression of magnetic streamlines and the self-consistent determination of the virtual cathode location. The radial dependence of the applied magnetic field is used to determine the critical parameters of this locally one-dimensional treatment. The theory has been incorporated into the ATHETA magnetic field code to allow the rapid evaluation of realistic magnetic field configurations. Comparisons between the theoretical results, simulations with the QUICKSILVER code, and experiments on the PBFA-X accelerator establish the usefulness of this tool for tuning magnetic fields to improve ion beam uniformity. The consequences of poor beam uniformity on the evolution of ion diode instabilities are discussed with supporting evidence from simulations, theory, and experiments. (author). 8 figs., 15 refs.

  8. Decontamination of Metal Ions in Soil by Supercritical CO{sub 2} Extraction with Catecholamine Ligand

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jihye; Kim, Hakwon; Park, Kwangheon [Kyunghee University, Yongin (Korea, Republic of)

    2015-10-15

    The role of fuel cladding and reactor vessels is to help prevent the leakage of radioactive materials, including the fission products. However, if these shielding materials are damaged by a severe disaster such as the Fukushima Accident, radioactive materials could leak outside of a power plant site. Indeed, after the Fukushima Accident, radioactive materials have been detected in air and water samples. The air and water pollution lead to soil pollution, which is particularly difficult to decontaminate, as soil pollution has several types that vary according to the characteristics of a pollutant or its area. The existing decontamination methods generate a secondary waste owing to use of chemical toxicity solvents. It is also disadvantageous due to the additional cost of handling them. Therefore, new effective decontamination methods that reduce the use of toxicity solvents are necessary. For example, using supercritical CO{sub 2} has been studied as a new decontamination method. This study examines the method of decontaminating metallic ions inside of the soil using supercritical CO{sub 2} and a catecholamine compound. This study examined the effects of extracting metallic ions inside the soil using supercritical CO{sub 2} and catecholamine as the ligand. Based on these results, it is evident that when only the extraction agent was used, there was no extraction effect and that only when the ligand, co-ligand, and additive were used together was there an extraction effect. Following this, the optimal extraction-agent ratio was confirmed using varying amounts of extraction agents. The most effective extraction ratio of ligand to co-ligand was 1:2 in E-9 when 0.3 ml of H{sub 2}O were added.

  9. Development of novel solvent extraction system by utilizing the metal ions excitation with ultraviolet pulse laser

    International Nuclear Information System (INIS)

    Saeki, Morihisa; Sasaki, Yuji; Yokoyama, Atsushi

    2010-01-01

    Novel liquid-liquid extraction technique was developed using ultraviolet pulse laser. The liquid-liquid system was composed of pure water and the 1-octanol solution of EuCl 3 and TODGA (TODGA = N,N,N',N'-tetraoctyl-diglycolamide). The Eu 3+ ion, which was formed to be the Eu 3+ (TODGA) n complex in 1-octanol, was reduced to Eu 2+ by irradiation of fourth harmonic of Nd:YAG laser (266 nm). The Eu 2+ ion was stabilized by addition of 15-Crown-5 (15C5). The observation by in-situ emission spectroscopy showed that the Eu 2+ ion reduced by the 266 nm-laser irradiation resulted in back-extraction of Eu from the 1-octanol solution to the water. The emission spectrum observed in 1-octanol suggested the change from the Eu 3+ (TODGA) n to the Eu 2+ (15C5) m complex after the reduction by the 266 nm laser. Time dependence of the concentration of Eu 2+ (15C5) m was investigated at the aqueous phase, the organic one and their interface. The results suggest that (1) rapid formation of Eu 2+ (15C5) m in 1-octanol after the irradiation of the 266 nm laser, (2) slow diffusion of Eu 2+ (15C5) m in 1-octanol, and (3) existence of time-lag between the formation of Eu 2+ (15C5) m in 1-octanol and its back-extraction to the water. (author)

  10. Feasibility study of a transversely polarized target in PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadi, Heybat; Deiseroth, Malte; Khaneft, Dmitry; Noll, Oliver; Valente, Roserio; Zambrana, Manuel [Helmholtz-Institut Mainz (Germany); Johannes Gutenberg-Universitaet Mainz (Germany); Ahmed, Samer [Helmholtz-Institut Mainz (Germany); Capozza, Luigi; Dbeyssi, Alaa; Froehlich, Bertold; Lin, Dexu; Maas, Frank; Mora Espi, Maria Carmen; Morales Morales, Cristina; Rodriguez Pineiro, David; Zimmermann, Iris [Helmholtz-Institut Mainz (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany)

    2015-07-01

    The PANDA (Antiproton Annihilation at Darmstadt) spectrometer, located at the Facility for Antiproton and Ion Research (FAIR), is an excellent tool for exploring the nucleon structure. An unpolarized target allows the determination of the electromagnetic time-like form factor of the proton. An additional experiment in which the target is transversely polarized is necessary for the first-time extraction of their imaginary part. A transverse polarization requires the shielding of the 2 T longitudinal field from the PANDA-Solenoid at the target volume and an additional transverse holding field. We present results from our first experiment at the Institut fuer Kernphysik in Mainz on intense magnetic flux shielding using a BSCCO (bismuth strontium calcium copper oxide) thin-wall hollow cylinder at 4.2 K and a 1.4 T external magnetic field and compare this to numerical calculations.

  11. Transverse myelitis

    International Nuclear Information System (INIS)

    Black, M.J.; Motaghedi, B.; Robitaille, Y.

    1980-01-01

    Transverse myelitis is a known complication of radiation treatment for carcinoma of the heat and neck. In a five year period, 1970 to 1975, 120 patients with head and neck cancer received radiation as part of their treatment in this hospital. A review of the records of these patients showed only two cases of myelitis, an incidence of about 2%. This paper reviews the clinical syndrome; treatment and preventive measures are discussed and a survey of the literature is presented

  12. Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

    Science.gov (United States)

    Fritz, James S.; Arena, Matteo P.; Steiner, Steven A.; Porter, Marc D.

    2003-01-01

    We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

  13. Improvement of the cloud point extraction of uranyl ions by the addition of ionic liquids.

    Science.gov (United States)

    Gao, Song; Sun, Taoxiang; Chen, Qingde; Shen, Xinghai

    2013-12-15

    The cloud point extraction (CPE) of uranyl ions by different kinds of extractants in Triton X-114 (TX-114) micellar solution was investigated upon the addition of ionic liquids (ILs) with various anions, i.e., bromide (Br(-)), tetrafluoroborate (BF4(-)), hexafluorophosphate (PF6(-)) and bis[(trifluoromethyl)sulfonyl]imide (NTf2(-)). A significant increase of the extraction efficiency was found on the addition of NTf2(-) based ILs when using neutral extractant tri-octylphosphine oxide (TOPO), and the extraction efficiency kept high at both nearly neutral and high acidity. However, the CPE with acidic extractants, e.g., bis(2-ethylhexyl) phosphoric acid (HDEHP) and 8-hydroxyquinoline (8-HQ) which are only effective at nearly neutral condition, was not improved by ILs. The results of zeta potential and (19)F NMR measurements indicated that the anion NTf2(-) penetrated into the TX-114 micelles and was enriched in the surfactant-rich phase during the CPE process. Meanwhile, NTf2(-) may act as a counterion in the CPE of UO2(2+) by TOPO. Furthermore, the addition of IL increased the separation factor of UO2(2+) and La(3+), which implied that in the micelle TOPO, NTf2(-) and NO3(-) established a soft template for UO2(2+). Therefore, the combination of CPE and IL provided a supramolecular recognition to concentrate UO2(2+) efficiently and selectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Modeling of negative ion extraction from a magnetized plasma source: Derivation of scaling laws and description of the origins of aberrations in the ion beam

    Science.gov (United States)

    Fubiani, G.; Garrigues, L.; Boeuf, J. P.

    2018-02-01

    We model the extraction of negative ions from a high brightness high power magnetized negative ion source. The model is a Particle-In-Cell (PIC) algorithm with Monte-Carlo Collisions. The negative ions are generated only on the plasma grid surface (which separates the plasma from the electrostatic accelerator downstream). The scope of this work is to derive scaling laws for the negative ion beam properties versus the extraction voltage (potential of the first grid of the accelerator) and plasma density and investigate the origins of aberrations on the ion beam. We show that a given value of the negative ion beam perveance correlates rather well with the beam profile on the extraction grid independent of the simulated plasma density. Furthermore, the extracted beam current may be scaled to any value of the plasma density. The scaling factor must be derived numerically but the overall gain of computational cost compared to performing a PIC simulation at the real plasma density is significant. Aberrations appear for a meniscus curvature radius of the order of the radius of the grid aperture. These aberrations cannot be cancelled out by switching to a chamfered grid aperture (as in the case of positive ions).

  15. 3D numerical simulations of negative hydrogen ion extraction using realistic plasma parameters, geometry of the extraction aperture and full 3D magnetic field map

    Science.gov (United States)

    Mochalskyy, S.; Wünderlich, D.; Ruf, B.; Franzen, P.; Fantz, U.; Minea, T.

    2014-02-01

    Decreasing the co-extracted electron current while simultaneously keeping negative ion (NI) current sufficiently high is a crucial issue on the development plasma source system for ITER Neutral Beam Injector. To support finding the best extraction conditions the 3D Particle-in-Cell Monte Carlo Collision electrostatic code ONIX (Orsay Negative Ion eXtraction) has been developed. Close collaboration with experiments and other numerical models allows performing realistic simulations with relevant input parameters: plasma properties, geometry of the extraction aperture, full 3D magnetic field map, etc. For the first time ONIX has been benchmarked with commercial positive ions tracing code KOBRA3D. A very good agreement in terms of the meniscus position and depth has been found. Simulation of NI extraction with different e/NI ratio in bulk plasma shows high relevance of the direct negative ion extraction from the surface produced NI in order to obtain extracted NI current as in the experimental results from BATMAN testbed.

  16. Process and device for the extraction of ions from a clear liquid or one containing matter in suspension with a ion exchanger

    International Nuclear Information System (INIS)

    Capitani, Enzo; Teissie, Jean.

    1982-01-01

    Process for the continuous extraction of ions from a clear liquid or one containing matter in suspension by the use of a bed of ion exchange grains which is fluidized inside a column by circulation of the liquid, characterized by the fact that the said bed is subject to cyclic pulsations, in order to obtain sorting of the grains by density, the heavier grains having fixed the maximum ions. This invention can be applied for the continuous extraction of any type of anion or cation or exchangeable salt by means of resins or inorganic exchangers, to avoid clogging and abrasion problems, and to obtain maximum extraction rate and capacity. An example is given of the treatment of a suspension for the extraction of uranium [fr

  17. Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fink, D. A.; Lettry, J.; Scrivens, R.; Steyaert, D. [CERN, 1211 Geneva 23 (Switzerland); Midttun, Ø. [University of Oslo, P.O. Box 1048, 0316 Oslo (Norway); CERN, 1211 Geneva 23 (Switzerland); Valerio-Lizarraga, C. A. [Departamento de Investigación en Fisica, Universidad de Sonora, Hermosillo (Mexico); CERN, 1211 Geneva 23 (Switzerland)

    2015-04-08

    The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

  18. Experimental study and simulation of the extraction conditions of a multicharged ion beam from an electron cyclotron resonance source

    International Nuclear Information System (INIS)

    Mandin, J.

    1996-01-01

    This thesis concerns the beam extraction studies of ECR Ion Sources for the SPIRAL project at GANIL (France). The optical properties (i.e. the emittances) of the radioactive ion beam production source is a crucial point in this project. We performed emittance measurements with a very high transport efficiency and developed a computer code for simulating the extraction and transport conditions. This simulation takes into account all the parameters acting on the extraction process: the characteristics of the ions and electrons emitted by the plasma, their space and energy distributions, the space charge, the magnetic filed of the source and the accelerating electric field. We explained the evolution of the emittances for two different types of ECR Ion Source. The simulation-experiment comparison showed us that the magnetic field and the intrinsic energy of the ions seem to be the most important parameters for explaining the overall emittance behaviour of the ECRIS. We precise their values and comment them. (author)

  19. Microwave frequency dependence of the properties of the ion beam extracted from a CAPRICE type ECRIS

    International Nuclear Information System (INIS)

    Maimone, F.; Tinschert, K.; Spaedtke, P.; Maeder, J.; Rossbach, J.; Lang, R.; Celona, L.

    2012-01-01

    In order to improve the quality of ion beams extracted from ECR ion sources it is mandatory to better understand the relations between the plasma conditions and the beam properties. The present investigations concentrate on the analysis of different beam properties under the influence of various applications of frequency tuning and of multiple frequency heating. The changes in the microwave frequency feeding the plasma affect the electromagnetic field distribution and the dimension and position of the ECR surface inside the plasma chamber. This in turn has an influence on the generation of the extracted ion beam in terms of intensity, shape and emittance. In order to analyze the corresponding effects, measurements have been performed with the CAPRICE-Type ECRIS installed at the ECR Injector Setup (EIS) of GSI. The experimental setup uses a microwave sweep generator which feeds a TWTA (Traveling Wave Tube Amplifier) covering a wide frequency range from 12.5 to 16.5 GHz. This arrangement provides a precise determination of the frequencies and of the reflection coefficient along with the beam properties and it confirms again how the frequency and the corresponding electromagnetic field feeding the plasma affects the ECRIS performances. A sequence of viewing targets positioned inside the beam line monitors the beam shape evolution. The paper is followed by the associated poster

  20. The effect of space charge force on beams extracted from ECR ion sources

    International Nuclear Information System (INIS)

    Xie, Z.Q.

    1989-01-01

    A new 3 dimensional ray tracing code BEAM-3D, with a simple model to calculate the space charge force of multiple ion species, is under development and serves as a theoretical tool to study the ECRIS beam formation. Excellent agreement between the BEAM-3D calculations and beam profile and emittance measurements of the total extracted helium 1+ beam from the RTECR ion source was obtained when a low degree of beam neutralization was assumed in the calculations. The experimental evidence indicates that the positive space charge effects dominate the early RTECR ion source beam formation and beamline optics matching process. A review of important beam characteristics is made, including a conceptual model for the space charge beam blow up. Better beam transport through the RTECR beamline analysis magnet has resulted after an extraction geometry modification in which the space charge force was more correctly matched. This work involved the development of an online beam characteristic measuring apparatus which will also be described

  1. Comparison of ONIX simulation results with experimental data from the BATMAN testbed for the study of negative ion extraction

    Science.gov (United States)

    Mochalskyy, Serhiy; Fantz, Ursel; Wünderlich, Dirk; Minea, Tiberiu

    2016-10-01

    The development of negative ion (NI) sources for the ITER neutral beam injector is strongly accompanied by modelling activities. The ONIX (Orsay Negative Ion eXtraction) code simulates the formation and extraction of negative hydrogen ions and co-extracted electrons produced in caesiated sources. In this paper the 3D geometry of the BATMAN extraction system, and the source characteristics such as the extraction and bias potential, and the 3D magnetic field were integrated in the model. Calculations were performed using plasma parameters experimentally obtained on BATMAN. The comparison of the ONIX calculated extracted NI density with the experimental results suggests that predictive calculations of the extraction of NIs are possible. The results show that for an ideal status of the Cs conditioning the extracted hydrogen NI current density could reach ~30 mA cm-2 at 10 kV and ~20 mA cm-2 at 5 kV extraction potential, with an electron/NI current density ratio of about 1, as measured in the experiments under the same plasma and source conditions. The dependency of the extracted NI current on the NI density in the bulk plasma region from both the modeling and the experiment was investigated. The separate distributions composing the NI beam originating from the plasma bulk region and the PG surface are presented for different NI plasma volume densities and NI emission rates from the plasma grid (PG) wall, respectively. The extracted current from the NIs produced at the Cs covered PG surface, initially moving towards the bulk plasma and then being bent towards the extraction surfaces, is lower compared to the extracted NI current from directly extracted surface produced ions.

  2. The solvent extraction of alkali metal ions with β-diketones

    International Nuclear Information System (INIS)

    Munakata, Megumu; Niina, Syozo; Shimoji, Noboru

    1974-01-01

    This work was undertaken to investigate effects of solvent and chelating-agent on the solvent extraction of alkali metal ions by seven β-diketones, acetylacetone (Acac), benzoylacetone (BzA), dipivaloylmethane (DPM), dibenzoylmethane (DBM), thenoyltrifluoloacetone (TTA), benzoyltrifluoroacetone (BFA) and hexafluoroacetylacetone (HFA), and to separate lithium from alkali metals. The extraction of alkali metals increase with increasing donor power of the solvent: i.e., benzene Na>K>Rb>Cs, which is also the order in which the adduct formation of these β-diketone chelates with donor solvents increase. The adduct formations between β-diketone chelates of alkali metals and donor solvents markedly enhance the solubilities of the chelates in solvents and, consequently, the extractabilities of alkali metals with β-diketones. Lithium was extracted with TTA in ether at such a low base concentration that sodium, potassium, rubidium and cesium were hardly extracted, and this enabled to separate lithium from other metals by the use of rubidium hydroxide (0.02 M). An attempt has been made to isolate alkali metal β-diketone chelates and some chelates have been obtained as crystals. The infrared absorption bands arising from C=O and C.=C of TTA shift to lower frequencies in the alkali metal chelates with TTA, and consequently, β-diketones is suggested to coordinate to alkali metal as a bidentate ligand. (JPN)

  3. submitter Light Extraction From Scintillating Crystals Enhanced by Photonic Crystal Structures Patterned by Focused Ion Beam

    CERN Document Server

    Modrzynski, Pawel; Knapitsch, Arno; Kunicki, Piotr; Lecoq, Paul; Moczala, Magdalena; Papakonstantinou, Ioannis; Auffray, Etiennette

    2016-01-01

    “Photonic Crystals (PhC)” have been used in a variety of fields as a structure for improving the light extraction efficiency from materials with high index of refraction. In previous work we already showed the light extraction improvement of several PhC covered LYSO crystals in computer simulations and practical measurements. In this work, new samples are made using different materials and techniques which allows further efficiency improvements. For rapid prototyping of PhC patterns on scintillators we tested a new method using “Focused Ion Beam (FIB)” patterning. The FIB machine is a device similar to a “Scanning Electron Microscope (SEM)”, but it uses ions (mainly gallium) instead of electrons for the imaging of the samples' surface. The additional feature of FIB devices is the option of surface patterning in nano-scale which was exploited for our samples. Three samples using FIB patterning have been produced. One of them is a direct patterning of the extraction face of a 0.8×0.8×10 $mm^3$ LYS...

  4. An efficient method for extracting plasma ions in laser isotope separation systems

    International Nuclear Information System (INIS)

    Demidova, N.S.; Mishin, V.A.

    2000-01-01

    The possibility of using a Hall-current accelerator to extract ions from a partially ionized plasma produced by selective laser isotope photoionization of atomic vapor is examined. A mechanism for ion acceleration is investigated using one-dimensional time-dependent equations of two-fluid magnetohydrodynamics. The current cutoff due to the ion space charge is prevented by electron emission. It is shown that, at an accelerating voltage of 25-50 V and emission current density of several mA/cm 2 , the ion component is accelerated throughout the entire plasma volume up to a velocity of ∼10 5 cm/s in a few microseconds. The influence of resonant charge exchange and secondary ionization by electrons on both the acceleration dynamics and selectivity degradation is taken into account. It is shown that the Hall-current extractor allows one to avoid selectivity degradation even when the plasma size exceeds the charge-exchange mean free path by one order of magnitude

  5. Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics.

    Science.gov (United States)

    Yorita, T; Hatanaka, K; Fukuda, M; Ueda, H; Yasuda, Y; Morinobu, S; Tamii, A; Kamakura, K

    2014-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

  6. Extraction Compression and Acceleration of High Line Charge Density Ion Beams

    CERN Document Server

    Henestroza, Enrique; Grote, D P; Peters, Craig; Yu, Simon

    2005-01-01

    HEDP applications require high line charge density ion beams. An efficient method to obtain this type of beams is to extract a long pulse, high current beam from a gun at high energy, and let the beam pass through a decelerating field to compress it. The low energy beam bunch is loaded into a solenoid and matched to a Brillouin flow. The Brillouin equilibrium is independent of the energy if the relationship between the beam size (a), solenoid magnetic field strength (B) and line charge density is such that (Ba)2

  7. Determination of nitrate in lettuce by ion chromatography after microwave water extraction

    Directory of Open Access Journals (Sweden)

    Humberto Brevilato Novaes

    2009-01-01

    Full Text Available Lettuce is worldwide known as the most important vegetable. In this context, most farmers are searching new techniques for best quality products including hydropony. However, nitrate is of great concern, since it has a negative impact on human metabolism. The main objective of the present work was to evaluate the nitrate content of lettuce produced by conventional and hydroponic systems. The determination was conducted by ion chromatography and a new method of extraction was tested using microwave oven digestion. The results indicated that nitrate level produced in the conventional system was lower than in the hydroponic system.

  8. Optimized Extraction of H– by Three-Electrode Faraday Cup System in Magnetized Sheet Plasma Ion Source

    Directory of Open Access Journals (Sweden)

    M. S. Fernandez

    2003-06-01

    Full Text Available A locally designed rectangular parallelepiped, three-electrode Faraday cup system has been developed.Its design incorporates the capability of simultaneous extraction and deposition of the H– ions on substrates.The device functions to attain prescribed selectivity conditions of extracted ions, with controlled energies,for deposition or adsorption. It has been proven to detect the ions at filter bias voltage of 13.61 V with acurrent density of 5.3 A/m2 that is relatively higher than reported (Abate & Ramos, 2000.

  9. Ion trace detection algorithm to extract pure ion chromatograms to improve untargeted peak detection quality for liquid chromatography/time-of-flight mass spectrometry-based metabolomics data.

    Science.gov (United States)

    Wang, San-Yuan; Kuo, Ching-Hua; Tseng, Yufeng J

    2015-03-03

    Able to detect known and unknown metabolites, untargeted metabolomics has shown great potential in identifying novel biomarkers. However, elucidating all possible liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS) ion signals in a complex biological sample remains challenging since many ions are not the products of metabolites. Methods of reducing ions not related to metabolites or simply directly detecting metabolite related (pure) ions are important. In this work, we describe PITracer, a novel algorithm that accurately detects the pure ions of a LC/TOF-MS profile to extract pure ion chromatograms and detect chromatographic peaks. PITracer estimates the relative mass difference tolerance of ions and calibrates the mass over charge (m/z) values for peak detection algorithms with an additional option to further mass correction with respect to a user-specified metabolite. PITracer was evaluated using two data sets containing 373 human metabolite standards, including 5 saturated standards considered to be split peaks resultant from huge m/z fluctuation, and 12 urine samples spiked with 50 forensic drugs of varying concentrations. Analysis of these data sets show that PITracer correctly outperformed existing state-of-art algorithm and extracted the pure ion chromatograms of the 5 saturated standards without generating split peaks and detected the forensic drugs with high recall, precision, and F-score and small mass error.

  10. Evaluation of metal ions in rice samples: extraction and direct determination by ICP OES

    International Nuclear Information System (INIS)

    Oliveira, Andrea; Cadore, Solange; Baccan, Nivaldo

    2012-01-01

    A method for extraction of metal ions present in rice samples using ammoniacal EDTA solution, pH = 10, as extractor agent is proposed under the following optimized conditions: 0.20 g of rice sample and 5.00 mL of ammoniacal EDTA (ethylenediaminetetraacetic acid) solution, with 5 min of ultrasound exposure time. Using robust ICP OES (inductively coupled plasma atomic emission spectrometry) conditions, direct analysis of the extraction solution was allowed, and the recovery values obtained were above 90% for most of the studied elements (P, K, Mg, Ca, Zn, Mn, Cu and Mo) with RSD -1 (Mn) - 48.68 mg kg -1 (K), showing adequate detectability for the determination of the analytes. The analysis of different samples indicated that Brazilian 'integral' rice contains higher contents of the constituents studied, followed by 'parboiled' rice, and the 'agulhinha' rice a long and thin grain type. (author)

  11. Extraction of trivalent actinides and lanthanides from nitric acid solutions by ion flotation

    International Nuclear Information System (INIS)

    Mezhov, E.H.; Samatov, A.V.; Troyanovskiy, L.V.

    1992-01-01

    To determine whether the deep extraction of trivalent actinides from liquid active waste is feasible, the authors made a detailed investigation into the ion flotation of europium (as a simulator of americium) and americium from nitric acid solutions by using as an SAS precipitant either lauril phosphoric acid (LPA) to reprocess 0.1-0.7 M HNO 3 or diphosphine dioxides (PO) for 1-5 M HNO 3 . In all instances the extent of metal removal increases with floto-reagent expenditure. When the floto-reagent excess required for full precipitation is reached, the extraction of the metals under study is high, viz., 97-98% from 0.1 M HNO 3 with LPA and ∼75% from 3-3.5 M HNO 3 with PO per one flotation operation

  12. Preparation of stable alginate microcapsules coated with chitosan or polyethyleneimine for extraction of heavy metal ions.

    Science.gov (United States)

    Outokesh, Mohammad; Mimura, Hitoshi; Niibori, Yuichi; Tanaka, Kouichi

    2006-05-01

    Stable alginate microcapsules in dried form containing bis(2,4,4-trimethylpentyl) monothiophosphinic acid (HA) were prepared by coating of fresh alginate microcapsules with chitosan or polyethyleneimine (PEI). The thickness of coatings was estimated by electron probe microanalysis (EPMA), along with electron microscopy (SEM), as well as comparison of uptake percentage of coated and uncoated hollow capsules. Characterization of microcapsules was carried out by Ag(+) uptake experiments, destructive chemical analyses and thermogravimetric methods (TG and DTA). Chemical stability tests in HNO(3) and NaNO(3) media indicated that the coating with 4-double layer chitosan or mono-layer PEI led to an appreciable enhancement of impermeability in the range of pH > 1 or [Na(+)] microcapsules nearly completely hold their extractant content. Stable extractive microcapsules have an appreciable potential for the selective removal of heavy metal ions.

  13. Extraction of cobalt ion from textile using a complexing macromolecular surfactant in supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Chirat, Mathieu; Ribaut, Tiphaine; Clerc, Sebastien; Lacroix-Desmazes, Patrick; Charton, Frederic; Fournel, Bruno

    2013-01-01

    Cobalt ion under the form of cobalt nitrate is removed from a textile lab coat using supercritical carbon dioxide extraction. The process involves a macromolecular additive of well-defined architecture, acting both as a surfactant and a complexing agent. The extraction efficiency of cobalt reaches 66% when using a poly(1,1,2,2-tetrahydroperfluoro-decyl-acrylate-co-vinyl-benzylphosphonic diacid) gradient copolymer in the presence of water at 160 bar and 40 C. The synergy of the two additives, namely the copolymer and water which are useless if used separately, is pointed out. The potential of the supercritical carbon dioxide process using complexing macromolecular surfactant lies in the ability to modulate the complexing unit as a function of the metal as well as the architecture of the surface-active agent for applications ranging for instance from nuclear decontamination to the recovery of strategic metals. (authors)

  14. Determination of Zinc Ions in Environmental Samples by Dispersive Liquid- Liquid Micro Extraction and Atomic Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Arabi

    2012-11-01

    Full Text Available In this work preconcentration of the Zn ions was investigated in water sample by Dispersive liquid- liquid micro extraction (DLLME using chloroform as an extraction solvent, methanol as a disperser solvent and 8-Hydroxyquinoline as a chelating agent. The determination of extracted ions was done by graphite furnace atomic absorption spectrometry. The influence of various analytical parameters including pH, extraction and disperser solvent type and volume and concentration of the chelating agent on the extraction efficiency of analyses was investigated. After extraction, the enrichment factor was 26 and the detection limit of the method was 0.0033 µg l-1 and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Zn were 7.41%. 

  15. Radium separation through complexation by aqueous crown ethers and ion exchange or solvent extraction

    Energy Technology Data Exchange (ETDEWEB)

    Chiarizia, R.; Dietz, M.L.; Horwitz, E.P. [Argonne National Lab., IL (United States). Chemistry Div.; Burnett, W.C. [Florida State Univ., Tallahassee, FL (United States). Dept. of Oceanography

    1997-11-01

    The effect of three water-soluble, unsubstituted crown ethers (15-crown-5 (15C5), 18-crown-6 (18C6) and 21-crown-7 (21C7)) on the uptake of Ca, Sr, Ba and Ra cations by a sulfonic acid cation exchange resin, and on the extraction of the same cations by xylene solutions of dinonylnaphthalenesulfonic acid (HDNNS) from aqueous hydrochloric acid solutions has been investigated. The crown ethers enhance the sorption of the larger cations by the ion exchange resin, thereby improving the resin selectivity over calcium, a result of a synergistic interaction between the crown ether and the ionic functional groups of the resin. Similarly, the extraction of the larger alkaline earth cations into xylene by HDNNS is strongly synergized by the presence of the crown ethers in the aqueous phase. Promising results for intra-Group IIa cation separations have been obtained using each of the three crown ethers as the aqueous ligands and the sulfonic acid cation exchange resin. Even greater separation factors for the radium-calcium couple have been measured with the crown-ethers and HDNNS solutions in the solvent extraction mode. The application of the uptake and extraction results to the development of radium separation schemes is discussed and a possible flowchart for the determination of {sup 226}Ra/{sup 228}Ra in natural waters is presented.

  16. Asparagus cochinchinensis Extract Alleviates Metal Ion-Induced Gut Injury in Drosophila: An In Silico Analysis of Potential Active Constituents

    Directory of Open Access Journals (Sweden)

    Weiyu Zhang

    2016-01-01

    Full Text Available Metal ions and sulfate are components of atmospheric pollutants that have diverse ways of entering the human body. We used Drosophila as a model to investigate the effect of Asparagus cochinchinensis (A. cochinchinensis extracts on the gut and characterized gut homeostasis following the ingestion of metal ions (copper, zinc, and aluminum. In this study, we found that the aqueous A. cochinchinensis extract increased the survival rate, decreased epithelial cell death, and attenuated metal ion-induced gut morphological changes in flies following chronic exposure to metal ions. In addition, we screened out, by network pharmacology, six natural products (NPs that could serve as putative active components of A. cochinchinensis that prevented gut injury. Altogether, the results of our study provide evidence that A. cochinchinensis might be an effective phytomedicine for the treatment of metal ion-induced gut injury.

  17. Effects of Vanadium Ions in Different Oxidation States on Myosin ATPase Extracted from the Solitary Ascidian, Halocynthia roretzi (Drasche) : Biochemistry

    OpenAIRE

    HITOSHI, MICHIBATA; YUTAKA, ZENKO; KENJI, YAMADA; MASATO, HASEGAWA; TATSURO, TERADA; TAKAHARU, NUMAKUANI; Biological Institute, Faculty of Science, Toyama University; Biological Institute, Faculty of Science, Toyama University; Biological Institute, Faculty of Science, Toyama University; Biological Institute, Faculty of Science, Toyama University; Department of Chemistry, Toyama College of Technology; Marine Biological Station, Tohoku University

    1989-01-01

    Some ascidians are known to accumulate vanadium ion within their tissues by 10^6-fold as that in sea water and store the metal ion in its reduced tetravalent and/or trivalent states. It is also well known that phosphoenzymes are inhibited by pentavalent vanadium ion over a range of 10nM to 1mM. In the present experiment we have therefore examined the effects of vanadium ions in different oxidation states on the activity of myosin ATPase extracted from the mantle of the ascidian, Halocynthia r...

  18. Review of particle-in-cell modeling for the extraction region of large negative hydrogen ion sources for fusion

    Science.gov (United States)

    Wünderlich, D.; Mochalskyy, S.; Montellano, I. M.; Revel, A.

    2018-05-01

    Particle-in-cell (PIC) codes are used since the early 1960s for calculating self-consistently the motion of charged particles in plasmas, taking into account external electric and magnetic fields as well as the fields created by the particles itself. Due to the used very small time steps (in the order of the inverse plasma frequency) and mesh size, the computational requirements can be very high and they drastically increase with increasing plasma density and size of the calculation domain. Thus, usually small computational domains and/or reduced dimensionality are used. In the last years, the available central processing unit (CPU) power strongly increased. Together with a massive parallelization of the codes, it is now possible to describe in 3D the extraction of charged particles from a plasma, using calculation domains with an edge length of several centimeters, consisting of one extraction aperture, the plasma in direct vicinity of the aperture, and a part of the extraction system. Large negative hydrogen or deuterium ion sources are essential parts of the neutral beam injection (NBI) system in future fusion devices like the international fusion experiment ITER and the demonstration reactor (DEMO). For ITER NBI RF driven sources with a source area of 0.9 × 1.9 m2 and 1280 extraction apertures will be used. The extraction of negative ions is accompanied by the co-extraction of electrons which are deflected onto an electron dump. Typically, the maximum negative extracted ion current is limited by the amount and the temporal instability of the co-extracted electrons, especially for operation in deuterium. Different PIC codes are available for the extraction region of large driven negative ion sources for fusion. Additionally, some effort is ongoing in developing codes that describe in a simplified manner (coarser mesh or reduced dimensionality) the plasma of the whole ion source. The presentation first gives a brief overview of the current status of the ion

  19. Modeling of the negative ions extraction from a hydrogen plasma source. Application to ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Mochalskyy, S.

    2011-12-01

    The development of a high performance negative ion (NI) source constitutes a crucial step in the construction of a Neutral Beam Injector of the future fusion reactor ITER. NI source should deliver 40 A of H - or of D - . To address this problem in a realistic way, a 3D particles-in-cell electrostatic collisional code was developed. Binary collisions between the particles are introduced using Monte-Carlo collision scheme. This code called ONIX was used to investigate the plasma properties and the transport of the charged particles close to a typical extraction aperture. Results obtained from this code are presented in this thesis. They include negative ions and electrons 3D trajectories. The ion and electron current density profiles are shown for different local magnetic field configurations. Results of production, destruction, and transport of H - in the extraction region are also presented. The production of H - is investigated via 3 atomic processes: 1) electron dissociative attachment to the vibrationally excited molecules H 2 (v) in the volume, 2) interaction of the positive ions H + and H 2 + with the aperture wall and 3) collisions of the neutral gas H, H 2 with aperture wall. The influence of each process on the total extracted NI current is discussed. The extraction efficiency of H - from the volume is compared to the one of H - coming from the wall. Moreover, a parametric study of the H - surface production is presented. Results show the role of sheath behavior in the vicinity of the aperture developing a double layer structure responsible of the NI extraction limitations. The 2 following issues are also analysed. First the influence of the external extracted potential value on the formation of negative sheath and secondly the strength of the magnetic filter on the total extracted NI and co-extracted electron current. The suppression of the electron beam by the negative ion produced at the plasma grid wall is also discussed. Results are in good agreement

  20. Extraction of Trivalent La, Nd and Eu from Nitric Acid Solution by Ion quest-801 Loaded on Lewatit CA 9221

    International Nuclear Information System (INIS)

    Nowier, H.G; Metwally, S.S; Abd El-Rehim, S.S; Aly, H.F.

    2005-01-01

    The extraction of La 3+ , Nd 3+ and Eu 3+ from nitric acid medium by Lewatit CA 9221, Containing 2-ethylhexyl mono -2- ethylhexyl phosphonic acid ester, Ion quest-801, was studied. Batch experiments were carried out to investigate the effect of contact time, V/M ratio, extractant concentration, nitric acid molarity, lanthanide concentration and temperature. The data obtained are discussed in terms of extraction equilibrium and separation factors between the lanthanides as well as certain sorption models. Possible use of column chromatography containing the developed extractant material was assessed

  1. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  2. Recent Progress in the Development of Supercritical Carbon Dioxide-Soluble Metal Ion Extractants: Aggregation, Extraction, and Solubility Properties of Silicon-Substituted Alkylenediphosphonic Acids

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, Mark L.; McAlister, Daniel R.; Stepinski, Dominique C.; Zalupski, Peter R.; Dzilawa, Julie A.; Barrans, Richard E.; Hess, J.N.; Rubas, Audris V.; Chiarizia, Renato; Lubbers, Christopher M.; Scurto, Aaron M.; Brennecke, Joan F.; Herlinger, Albert W.

    2003-09-11

    Partially esterified alkylenediphosphonic acids (DPAs) have been shown to be effective reagents for the extraction of actinide ions from acidic aqueous solution into conventional organic solvents. Efforts to employ these compounds in supercritical fluid extraction have been hampered by their modest solubility in unmodified supercritical carbon dioxide (SC-CO2). In an effort to design DPAs that are soluble in SC-CO2, a variety of silicon-substituted alkylenediphosphonic acids have been prepared and characterized, and their behavior compared with that of conventional alkyl-substituted reagents. Silicon substitution is shown to enhance the CO2-philicity of the reagents, while other structural features, in particular, the number of methylene groups bridging the phosphorus atoms of the extractant, are shown to exert a significant influence on their aggregation and extraction properties. The identification of DPAs combining desirable extraction properties with adequate solubility in SC-CO2 is shown to be facilitated by the application of molecular connectivity indices.

  3. Extraction of metal ions using chemically modified silica gel: a PIXE analysis.

    Science.gov (United States)

    Jal, P K; Dutta, R K; Sudarshan, M; Saha, A; Bhattacharyya, S N; Chintalapudi, S N; K Mishra, B

    2001-08-30

    Organic ligand with carboxyhydrazide functional group was immobilised on the surface of silica gel and the metal binding capacity of the ligand-embedded silica was investigated. The functional group was covalently bonded to the silica matrix through a spacer of methylene groups by sequential reactions of silica gel with dibromobutane, malonic ester and hydrazine in different media. Surface area value of the modified silica was determined. The changes in surface area were correlated with the structural change of the silica surface due to chemical modifications. A mixture solution of metal ions [K(I),Cr(III),Co(II),Ni(II),Cu(II),Zn(II),Hg(II) and U(VI)] was treated with the ligand-embedded silica in 10(-3) M aqueous solution. The measurement of metal extraction capacity of the silica based ligand was done by multielemental analysis of the metal complexes thus formed by using Proton Induced X-ray Emission (PIXE) technique.

  4. Ion imprinted activated carbon solid-phase extraction coupled to flame atomic absorption spectrometry for selective determination of lead ions in environmental samples

    International Nuclear Information System (INIS)

    Naraghi, Kiyana; Panahi, Homayon Ahmad; Hassani, Amir Hesam; Moniri, Elham

    2014-01-01

    A simple lead ion imprinted sorbent was synthesized by coupling activated carbon with a known metal chelating compound, iminodiacetic acid. The ion imprinted sorbent has been characterized using Fourier transform infrared spectroscopy, elemental analysis and thermogravimetric analysis and subjected for the extraction and determination of trace Pb(II) in environmental water samples. The optimum pH value for sorption of the lead ion was 6.5. The sorption capacity of lead imprinted sorbent was 42.2 mg g"−"1. The chelating imprinted sorbent can be reused for five cycles of sorption-desorption without any significant change in sorption capacity. Compared with non-imprinted polymer particles, the lead ion imprinted sorbent showed high adsorption capacity, significant selectivity, good site accessibility for Pb(II). The equilibrium adsorption data of Pb(II) by modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich-Peterson models

  5. Ion imprinted activated carbon solid-phase extraction coupled to flame atomic absorption spectrometry for selective determination of lead ions in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Naraghi, Kiyana; Panahi, Homayon Ahmad; Hassani, Amir Hesam [Islamic Azad University, Tehran (Korea, Republic of); Moniri, Elham [Islamic Azad University, Varamin (Iran, Islamic Republic of)

    2014-10-15

    A simple lead ion imprinted sorbent was synthesized by coupling activated carbon with a known metal chelating compound, iminodiacetic acid. The ion imprinted sorbent has been characterized using Fourier transform infrared spectroscopy, elemental analysis and thermogravimetric analysis and subjected for the extraction and determination of trace Pb(II) in environmental water samples. The optimum pH value for sorption of the lead ion was 6.5. The sorption capacity of lead imprinted sorbent was 42.2 mg g{sup −1}. The chelating imprinted sorbent can be reused for five cycles of sorption-desorption without any significant change in sorption capacity. Compared with non-imprinted polymer particles, the lead ion imprinted sorbent showed high adsorption capacity, significant selectivity, good site accessibility for Pb(II). The equilibrium adsorption data of Pb(II) by modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich-Peterson models.

  6. Effect of the gas mixing technique on the production efficiency of ion beams extracted from an electron cyclotron resonance ion source

    International Nuclear Information System (INIS)

    Tarvainen, O.; Suominen, P.; Koivisto, H.

    2004-01-01

    In this work the effect of gas mixing on the production efficiency of ion beams extracted from an ECR ion source has been studied with the JYFL 6.4 GHz electron cyclotron resonance ion source (ECRIS). It was found that the gas mixing affects strongly the confinement of ions in the plasma of the ECRIS. The information obtained can be used to minimize the consumption of expensive materials or isotopes and to reduce contamination of the plasma chamber. It was observed that the carbon contamination, which is built up when the MIVOC method is used could be decreased with the aid of the gas mixing technique. The best mixing gas for this purpose was found to be oxygen

  7. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Bellodi, G; Dimov, V; Küchler, D; Lombardi, A M; Maintrot, M

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  8. Criticality in the fabrication of ion extraction system for SST-1 neutral beam injector

    International Nuclear Information System (INIS)

    Jana, M.R.; Mattoo, S.K.

    2008-01-01

    based on positive ion source. The extraction system consists of three grids, each having extraction area of (width) 230 mm x (height) 480 mm and 774-shaped apertures of 8-mm diameter. To obtain horizontal focal length of 5.4 m and vertical of 7 m, each grid consists of two halves with 387 apertures. Two halves are inclined at an angle of 1.07 ± 0.01 o . For long pulse operation, active water cooling is provided by in-laid down of dense network of 22 wavy semicircular (r = 1.1 ± 0.05 mm) cooling channels in the space available between the apertures. The required flatness of the copper plate is 100 μm and positioning tolerance of aperture is ±60 μm. The measurement obtained after fabrication is compared with the specifications. It is pointed out that fabrication within set tolerance limit could be achieved only through process of fabrication and high-resolution measurements

  9. Numerical modeling of the Linac4 negative ion source extraction region by 3D PIC-MCC code ONIX

    CERN Document Server

    Mochalskyy, S; Minea, T; Lifschitz, AF; Schmitzer, C; Midttun, O; Steyaert, D

    2013-01-01

    At CERN, a high performance negative ion (NI) source is required for the 160 MeV H- linear accelerator Linac4. The source is planned to produce 80 mA of H- with an emittance of 0.25 mm mradN-RMS which is technically and scientifically very challenging. The optimization of the NI source requires a deep understanding of the underling physics concerning the production and extraction of the negative ions. The extraction mechanism from the negative ion source is complex involving a magnetic filter in order to cool down electrons’ temperature. The ONIX (Orsay Negative Ion eXtraction) code is used to address this problem. The ONIX is a selfconsistent 3D electrostatic code using Particles-in-Cell Monte Carlo Collisions (PIC-MCC) approach. It was written to handle the complex boundary conditions between plasma, source walls, and beam formation at the extraction hole. Both, the positive extraction potential (25kV) and the magnetic field map are taken from the experimental set-up, in construction at CERN. This contrib...

  10. Aerosol-assisted extraction of silicon nanoparticles from wafer slicing waste for lithium ion batteries.

    Science.gov (United States)

    Jang, Hee Dong; Kim, Hyekyoung; Chang, Hankwon; Kim, Jiwoong; Roh, Kee Min; Choi, Ji-Hyuk; Cho, Bong-Gyoo; Park, Eunjun; Kim, Hansu; Luo, Jiayan; Huang, Jiaxing

    2015-03-30

    A large amount of silicon debris particles are generated during the slicing of silicon ingots into thin wafers for the fabrication of integrated-circuit chips and solar cells. This results in a significant loss of valuable materials at about 40% of the mass of ingots. In addition, a hazardous silicon sludge waste is produced containing largely debris of silicon, and silicon carbide, which is a common cutting material on the slicing saw. Efforts in material recovery from the sludge and recycling have been largely directed towards converting silicon or silicon carbide into other chemicals. Here, we report an aerosol-assisted method to extract silicon nanoparticles from such sludge wastes and their use in lithium ion battery applications. Using an ultrasonic spray-drying method, silicon nanoparticles can be directly recovered from the mixture with high efficiency and high purity for making lithium ion battery anode. The work here demonstrated a relatively low cost approach to turn wafer slicing wastes into much higher value-added materials for energy applications, which also helps to increase the sustainability of semiconductor material and device manufacturing.

  11. Optimization of LiCoO2 powder extraction process from cathodes of lithium-ion batteries by chemical dissolution

    OpenAIRE

    Lucas Evangelista Sita; Stephany Pires da Silva; Paulo Rogério Catarini da Silva; Alexandre Urbano; Jair Scarminio

    2015-01-01

    A chemical process has been applied to extract LiCoO2 powder from cathodes of spent lithium-ion batteries by dissolution of the binder that agglutinate the powder particle each other as well to the Al collector surface. As solvents dimethylformamide (DMF) and N-methyilpirrolidone (NMP) were employed and the variables, cathode area, solution temperature, ultrasound bath power and solution stirring were chosen to optimize the extraction process. NMP solutions presented best results for powder e...

  12. Characteristics of a betatron core for extraction in a proton-ion medical synchrotron

    CERN Document Server

    Badano, L

    1997-01-01

    Medical synchrotrons for radiation therapy require a very stable extraction of the beam over a period of about one second. The techniques for applying resonant extraction to achieve this long spill can be classified into two groups, those that move the resonance and those that move the beam. The latter has the great advantage of keeping all lattice functions, and hence the resonance conditions, constant. The present report examines the possibility of using a betatron core to accelerate the waiting ion beam by induction into the resonance. The working principle, the proposed characteristics and the expected performances of this device are discussed. The betatron core is a smooth high-inductance device compared to the small quadrupole lenses that are normally used to move the resonance and is therefore better suited to delivering a very smooth spill. The large stored energy in a betatron core compared to a small quadrupole is also a safety feature since it responds less quickly to transients that could send lar...

  13. Performance of multi-aperture grid extraction systems for an ITER-relevant RF-driven negative hydrogen ion source

    Science.gov (United States)

    Franzen, P.; Gutser, R.; Fantz, U.; Kraus, W.; Falter, H.; Fröschle, M.; Heinemann, B.; McNeely, P.; Nocentini, R.; Riedl, R.; Stäbler, A.; Wünderlich, D.

    2011-07-01

    The ITER neutral beam system requires a negative hydrogen ion beam of 48 A with an energy of 0.87 MeV, and a negative deuterium beam of 40 A with an energy of 1 MeV. The beam is extracted from a large ion source of dimension 1.9 × 0.9 m2 by an acceleration system consisting of seven grids with 1280 apertures each. Currently, apertures with a diameter of 14 mm in the first grid are foreseen. In 2007, the IPP RF source was chosen as the ITER reference source due to its reduced maintenance compared with arc-driven sources and the successful development at the BATMAN test facility of being equipped with the small IPP prototype RF source ( {\\sim}\\frac{1}{8} of the area of the ITER NBI source). These results, however, were obtained with an extraction system with 8 mm diameter apertures. This paper reports on the comparison of the source performance at BATMAN of an ITER-relevant extraction system equipped with chamfered apertures with a 14 mm diameter and 8 mm diameter aperture extraction system. The most important result is that there is almost no difference in the achieved current density—being consistent with ion trajectory calculations—and the amount of co-extracted electrons. Furthermore, some aspects of the beam optics of both extraction systems are discussed.

  14. Performance of multi-aperture grid extraction systems for an ITER-relevant RF-driven negative hydrogen ion source

    International Nuclear Information System (INIS)

    Franzen, P.; Gutser, R.; Fantz, U.; Kraus, W.; Falter, H.; Froeschle, M.; Heinemann, B.; McNeely, P.; Nocentini, R.; Riedl, R.; Staebler, A.; Wuenderlich, D.

    2011-01-01

    The ITER neutral beam system requires a negative hydrogen ion beam of 48 A with an energy of 0.87 MeV, and a negative deuterium beam of 40 A with an energy of 1 MeV. The beam is extracted from a large ion source of dimension 1.9 x 0.9 m 2 by an acceleration system consisting of seven grids with 1280 apertures each. Currently, apertures with a diameter of 14 mm in the first grid are foreseen. In 2007, the IPP RF source was chosen as the ITER reference source due to its reduced maintenance compared with arc-driven sources and the successful development at the BATMAN test facility of being equipped with the small IPP prototype RF source ( ∼ 1/8 of the area of the ITER NBI source). These results, however, were obtained with an extraction system with 8 mm diameter apertures. This paper reports on the comparison of the source performance at BATMAN of an ITER-relevant extraction system equipped with chamfered apertures with a 14 mm diameter and 8 mm diameter aperture extraction system. The most important result is that there is almost no difference in the achieved current density-being consistent with ion trajectory calculations-and the amount of co-extracted electrons. Furthermore, some aspects of the beam optics of both extraction systems are discussed.

  15. Feasibility study of a transversely polarized target in PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Bertold [Helmholtz Institut Mainz (Germany)

    2014-07-01

    PANDA (Antiproton Annihilation at Darmstadt) is a key project at the Facility for Antiproton and Ion Research (FAIR), currently under construction at the GSI Darmstadt. PANDA is a state of the art detector for antiproton-proton fixed target experiments. A transversely polarized target in PANDA would allow the determination of the proton electromagnetic form factors in the time-like region with unprecedented accuracy and the first-time extraction of their imaginary part, opening a new window for investigating the nucleon structure. As a first step for achieving a transverse target polarization, the target region has to be shielded against the 2 T longitudinal magnetic flux from the solenoid of the PANDA spectrometer. We present numerical simulations and experimental results on intense magnetic flux shielding using a high temperature superconducting hollow cylinder.

  16. Synthesis of silver nanoparticles using Matricaria recutita (Babunah plant extract and its study as mercury ions sensor

    Directory of Open Access Journals (Sweden)

    Imran Uddin

    2017-11-01

    Full Text Available Silver (Ag nanoparticles comprise a highly selective approach for development of nanosensors for the detection of Hg2+ ions. When Ag nanoparticles mixes with Hg2+ ions, loses its UV–Vis absorption intensity. Here, green synthesis of Ag nanoparticles was done using plant extract of Matricaria recutita (Babunah under ambient conditions. Biosynthesized Ag nanoparticles are well-dispersed having quasi-spherical shape and average particle size of 11nm. XRD, SAED and HRTEM analysis showed that nanoparticles are well crystalline in nature and having cubic phase of geometry. We report here highly selective colorimetric detection of mercury ions (Hg2+ using biosynthesized Ag nanoparticles. Keywords: Herbal extract, Nanosensor, Biosynthesis, Matricaria recutita, Silver nanoparticles

  17. Hemispherand-Strapped Calix[4]pyrrole: An Ion-pair Receptor for the Recognition and Extraction of Lithium Nitrite.

    Science.gov (United States)

    He, Qing; Zhang, Zhan; Brewster, James T; Lynch, Vincent M; Kim, Sung Kuk; Sessler, Jonathan L

    2016-08-10

    The hemispherand-strapped calix[4]pyrrole (1) acts as an ion pair receptor that exhibits selectivity for lithium salts. In organic media (CD2Cl2 and CD3OD, v/v, 9:1), receptor 1 binds LiCl with high preference relative to NaCl, KCl, and RbCl. DFT calculations provided support for the observed selectivity. Single crystal structures of five different lithium ion-pair complexes of 1 were obtained. In the case of LiCl, a single bridging water molecule between the lithium cation and chloride anion was observed, while tight contact ion pairs were observed in the case of the LiBr, LiI, LiNO3, and LiNO2 salts. Receptor 1 proved effective as an extractant for LiNO2 under both model solid-liquid and liquid-liquid extraction conditions.

  18. Novel ion-imprinted polymer coated on nanoporous silica as a highly selective sorbent for the extraction of ultratrace quantities of gold ions from mine stone samples

    International Nuclear Information System (INIS)

    Ebrahimzadeh, H.; Moazzen, E.; Amini, M.; Sadeghi, O.

    2013-01-01

    We have developed a gold ion-imprinted polymer (GIP) by incorporating a dipyridyl ligand into an ethylene glycol dimethacrylate matrix which then was coated onto porous silica particles. The material was used for the selective extraction of ultratrace quantities of gold ion from mine stones, this followed by its quantitation by FAAS. The effects of concentration and volume of eluent, pH of the solution, flow rates of sample and eluent, and effect of potentially interfering ions, especially palladium and platinum, was investigated. The limit of detection is -1 , the precision (RSD%) is 1.03 %, and recoveries are >99 %. In order to show the high selectivity and efficiency of the new sorbent, the results were compared to those obtained with more simple sorbents possessing the same functional groups. The accuracy of the method was demonstrated by the accurate determination of gold ions in a certified reference material. To the best of our knowledge, there is no report so far on an imprint for gold ions that has such a selectivity over Pd(II) and Pt(II) ions. (author)

  19. Improved beam extraction for a negative hydrogen ion source for the LHC injector chain upgrade, Linac4

    CERN Document Server

    Midttun, Øystein; Scrivens, Richard

    In the scope of an upgrade of the injector chain of CERN’s accelerator complex, a new linear accelerator, Linac4, is under construction. This accelerator will replace the existing 50 MeV proton linac, Linac2. By increasing the beam energy to 160 MeV, Linac4 makes it possible to double the brightness in the PSB, and ultimately increase the luminosity in the LHC. Linac4 will accelerate beams of negative hydrogen (H-) to be injected into the PSB by multi-turn, charge exchange injection. The ion source was initially based on the non-caesiated RF-volume source from DESY. However, the beam extraction from this source could not handle the 45 keV beam energy required by the RFQ. A new beam extraction system has therefore been designed, via IBSimu simulations [1], to extract and transport the H- ion beam respecting the Linac4 requirements. Key features of the extraction system is a tuneable puller voltage to adapt the extraction field to the ion and electron beam currents, and a magnetized Einzel lens to dump the co...

  20. Liquid-liquid extraction of ion-association complexes of cobalt(II-4-(2-pyridylazoresorcinol with ditetrazolium salts

    Directory of Open Access Journals (Sweden)

    Divarova Vidka V.

    2015-01-01

    Full Text Available The formation and liquid-liquid extraction of ion-association complexes between Co(II-4-(2-Pyridylazoresorcinol (PAR anionic chelates and cations of three ditetrazolium chlorides were studied: Blue Tetrazolium chloride (BTC, Neotetrazolium chloride (NTC and Nitro Blue Tetrazolium chloride (NBT. The optimum conditions for the formation and solvent extraction of the ion-association comlpex chelates were determined. It has been found that in the systems of Co(II-PAR-DTS, the reactants are reacted in molar ratios 1:2:1 and the general formula of complexes was suggested. The extraction equilibria were investigated and quantitatively characterized by the equilibrium constants and the recovery factors. The analytical characteristics of the complexes were calculated.

  1. Two-dimensional evaluation of an ion plasma produced by pulsed lasers extracted by non-parallel collectors

    International Nuclear Information System (INIS)

    Mahdieh, M H; Gavili, A

    2003-01-01

    Two-dimensional hydrodynamics of ion extraction from quasi-neutral plasmas has been calculated numerically for non-parallel ion extractors, and the results compared with those for the parallel case. The ions were assumed to be initially uniform with a very steep density profile at the boundaries, and held between two non-parallel metal plates as cathode and anode with fixed potentials. Experimentally, tunable pulsed lasers through stepwise photo-excitation and photo-ionization or multi-photo-ionization processes can produce such plasma. Poisson's equation was solved simultaneously with the equations of mass and momentum, assuming the Maxwell-Boltzmann distribution for electrons. Ordinary Cartesian co-ordinates are not suitable for the rotated extractor geometry; therefore using the 'algebraic method' a transformation from the physical domain into the computational rectangular plane is applied for analysing the irregular boundaries. Such a technique provides adequate resolution for the boundary layer. Using a first-order explicit upwind differencing in an appropriate transformed Cartesian co-ordinate system, the hydrodynamics of the plasma ions between the two non-parallel electrodes was evaluated. In these calculations electric potential, ion density between the two electrodes, and the extraction time were assessed, considering three separate regions for the plasma, i.e. the ion sheath where (n i >>n e ∼0), the transition region (pre-sheath) (n i = n e ), and the quasi-neutral plasma (n i -n e i ). The results were compared with those for parallel electrodes. A significant discrepancy was found between the two results. From the calculation, the non-uniform asymmetric potential contour, and the ion density contour across the plasma, were obtained for the non-parallel electrodes. For comparison with the parallel extractors, we have also obtained almost the same extraction time for the non-parallel extractors

  2. On the electron extraction in a large RF-driven negative hydrogen ion source for the ITER NBI system

    International Nuclear Information System (INIS)

    Franzen, P; Wünderlich, D; Fantz, U

    2014-01-01

    The test facility ELISE, equipped with a large RF-driven ion source (1 × 0.9 m 2 ) of half the size of the ion source for the ITER neutral beam injection (NBI) system, has been constructed over the last three years at the Max-Planck-Institut für Plasmaphysik (IPP), Garching, and is now operational. The first measurements of the dependence of the co-extracted electron currents on various operational parameters have been performed. ELISE has the unique feature that the electron currents can be measured individually on both extraction grid segments, leading to vertical spatial resolution. Although performed in volume operation, where the negative hydrogen ions are created in the plasma volume solely, the results are very encouraging for operation with caesium, this being necessary in order to achieve the relevant negative ion currents for the ITER NBI injectors. The amount of co-extracted electrons could be suppressed sufficiently with moderate magnetic filter fields and by plasma grid bias. Furthermore, the electron extraction is more or less decoupled from the main plasma, as the observed vertical asymmetry of electron extraction is not correlated at all with the plasma asymmetry, which is anyway rather small. Both effects are superior to the experience from the small IPP prototype source; the reason for these encouraging results is most probably the larger size of the source as well as the new geometry of the source having unbiased areas in its centre. The reasons, however, for the observed asymmetry of the extracted electron currents and their dependencies on various operational parameters are not well understood. (paper)

  3. Supercritical Carbon Dioxide-Soluble Ligands for Extracting Actinide Metal Ions from Porous Solids

    International Nuclear Information System (INIS)

    Dietz, Mark L.

    2001-01-01

    Numerous types of actinide-bearing waste materials are found throughout the DOE complex. Most of these wastes consist of large volumes of non-hazardous materials contaminated with relatively small quantities of actinide elements. Separation of these wastes into their inert and radioactive components would dramatically reduce the costs of stabilization and disposal. For example, the DOE is responsible for decontaminating concrete within 7000 surplus contaminated buildings. The best technology now available for removing surface contamination from concrete involves removing the surface layer by grit blasting, which produces a large volume of blasting residue containing a small amount of radioactive material. Disposal of this residue is expensive because of its large volume and fine particulate nature. Considerable cost savings would result from separation of the radioactive constituents and stabilization of the concrete dust. Similarly, gas diffusion plants for uranium enrichment contain valuable high-purity nickel in the form of diffusion barriers. Decontamination is complicated by the extremely fine pores in these barriers, which are not readily accessible by most cleaning techniques. A cost-effective method for the removal of radioactive contaminants would release this valuable material for salvage. The objective of this project is to develop novel, substituted diphosphonic acid ligands that can be used for supercritical carbon dioxide extraction of actinide ions from solid wastes. Specifically, selected diphosphonic acids, which are known to form extremely stable complexes with actinides in aqueous and organic solution, are to be rendered carbon dioxide-soluble by the introduction of appropriate alkyl- or silicon-containing substituents. The metal complexation chemistry of these new ligands in SC-CO2 will then be investigated and techniques for their use in actinide extraction from porous solids developed

  4. High Charge State Ions Extracted from Metal Plasmas in the Transition Regime from Vacuum Spark to High Current Vacuum Arc

    International Nuclear Information System (INIS)

    Yushkov, Georgy Yu.; Anders, A.

    2008-01-01

    Metal ions were extracted from pulsed discharge plasmas operating in the transition region between vacuum spark (transient high voltage of kV) and vacuum arc (arc voltage ∼ 20 V). At a peak current of about 4 kA, and with a pulse duration of 8 (micro)s, we observed mean ion charges states of about 6 for several cathode materials. In the case of platinum, the highest average charge state was 6.74 with ions of charge states as high as 10 present. For gold we found traces of charge state 11, with the highest average charge state of 7.25. At currents higher than 5 kA, non-metallic contaminations started to dominate the ion beam, preventing further enhancement of the metal charge states

  5. Application of a Lithium-ion Selective Metallacrown to Extraction-Spectrophotometric Determination of Lithium in Saline Water.

    Science.gov (United States)

    Katsuta, Shoichi; Saito, Yuki; Takahashi, Suguru

    2018-01-01

    The solvent-extraction behavior of Li + and Na + with a Li + selective metallacrown, [{Ru(η 6 -3,5-dimethylanisole)(2,3-pyridinediolate)} 3 ], was investigated in the presence of organic dye anions, 3',3″,5',5″-tetrabromophenolphthalein ethyl ester ([TBPE] - ), 2,6-dichloroindophenolate, and picrate ([pic] - ). Each alkali metal ion was extracted as a 1:1:1 ternary complex of the metal ion, metallacrown, and anion. The Li + /Na + extraction selectivity is anion dependent and highest with [pic] - . Therefore, we devised an extraction-spectrophotometric determination method for Li + in saline water based on the extraction of Li + using the metallacrown and [pic] - for high selectivity and subsequent replacement of [pic] - in the extracted species with [TBPE] - for high sensitivity. When applying this to artificial seawater samples containing known concentrations of Li + , a linear relationship was observed between the absorbance at 571 nm of the organic phase and the Li + concentration in the samples. By this method, the determination of Li + at the sub-ppm level in natural seawater is possible.

  6. Recovery of cobalt from spent lithium-ion batteries using supercritical carbon dioxide extraction.

    Science.gov (United States)

    Bertuol, Daniel A; Machado, Caroline M; Silva, Mariana L; Calgaro, Camila O; Dotto, Guilherme L; Tanabe, Eduardo H

    2016-05-01

    Continuing technological development decreases the useful lifetime of electronic equipment, resulting in the generation of waste and the need for new and more efficient recycling processes. The objective of this work is to study the effectiveness of supercritical fluids for the leaching of cobalt contained in lithium-ion batteries (LIBs). For comparative purposes, leaching tests are performed with supercritical CO2 and co-solvents, as well as under conventional conditions. In both cases, sulfuric acid and H2O2 are used as reagents. The solution obtained from the supercritical leaching is processed using electrowinning in order to recover the cobalt. The results show that at atmospheric pressure, cobalt leaching is favored by increasing the amount of H2O2 (from 0 to 8% v/v). The use of supercritical conditions enable extraction of more than 95wt% of the cobalt, with reduction of the reaction time from 60min (the time employed in leaching at atmospheric pressure) to 5min, and a reduction in the concentration of H2O2 required from 8 to 4% (v/v). Electrowinning using a leach solution achieve a current efficiency of 96% and a deposit with cobalt concentration of 99.5wt%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Nagatomo, T., E-mail: nagatomo@riken.jp; Kase, M.; Kamigaito, O.; Nakagawa, T. [Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan); Tzoganis, V. [Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan); Cockcroft Institute, Daresbury, Warrington WA4 4AD (United Kingdom); Department of Physics, University of Liverpool, Liverpool, Merseyside L69 3BX (United Kingdom)

    2016-02-15

    Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

  8. Extracts and compounds active on TRP ion channels from Waldheimia glabra, a ritual medicinal plant from Himalaya.

    Science.gov (United States)

    Giorgi, Annamaria; Bassoli, Angela; Borgonovo, Gigliola; Panseri, Sara; Manzo, Alessandra; Pentimalli, Daniela; Schiano Moriello, Aniello; De Petrocellis, Luciano

    2017-08-15

    Waldheimia glabra (Decne.) Regel is a wild plant from the Himalayan Mountains, commonly known as Smooth Ground Daisy. This plant is traditionally used by local populations in religious rituals (incense) or in traditional herbal medicine to treat skin diseases, headache, joint pain and fever. In literature few data are available on the investigation of this aromatic plant. The present work aims at deepening knowledge about the chemical composition of W. glabra extracts and incense, as well as its activity on TRP ion channels. Extracts and incense of W. glabra were analyzed by using HS-SPME GC/MS, GC/MS and NMR analysis. Tests on the activity of W. glabra extracts and isolated compounds (+)-ludartin 1 and B-ring-homo-tonghaosu 2 on TRP channels were also performed. Some extracts and pure compounds from W. glabra showed an interesting activity in terms of efficacy and potency on rat TRPA1, an ion channel involved in several sensory mechanisms, including pungency, environmental irritation and pain perception. Activity is discussed and compared with that of other known TRPA1 natural agonists with different chemical structures. All compounds showed only a negligible inhibition activity on rat TRPM8 ion channel. Our findings demonstrate that W. glabra is involved in the receptor activation mechanism and therefore represents a new natural product potentially useful in pharmaceutical and agrifood research. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. Nano magnetic solid phase extraction for preconcentration of lead ions in environmental samples by a newly synthesized reagent.

    Science.gov (United States)

    Golshekan, Mostafa; Shariati, Shahab

    2013-01-01

    In this study, magnetite nanoparticles with particle size lower than 47 nm were synthesized and were applied for preconcentration of Pb2+ ions from aqueous solutions. To preconcentrate the Pb2+ ions, the surface of the synthesized nano particles was modified with sodium dodecyl sulfate (SDS) as an anionic surfactant. A new chelating agent (2-((E)-2-amino-4,5-dinitrophenylimino)methyl)phenol) was synthesized and used to form a very stable complex with Pb2+ ions. The lead ions formed complexes and were quantitatively extracted with SDS-coated magnetite nanoparticles. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v) HC1 in dimethyl sulfoxide (DMSO) prior to analysis by flame atomic absorption spectrometry (FAAS). Orthogonal array design (OAD) was used to study and optimize the different experimental parameters. Under the optimum conditions, enhancement factor up to 63.5 was achieved for extraction from only 10 mL of sample solution and the relative standard deviation (RSD %) of the method was lower than 2.8%. The obtained calibration curve was linear in the range of 1-300 pg L-' with reasonable linearity (r2 > 0.998). The limit of detection (LOD) based on S/N = 3 was 0.04 microg L(-1) for 10 mL sample volumes. Finally, applicability of the proposed method was successfully confirmed by preconcentration and determination of trace amounts of lead ions in environmental samples and satisfactory results were obtained.

  10. Fundamental studies of the plasma extraction and ion beam formation processes in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Niu, Hongsen.

    1995-01-01

    The fundamental and practical aspects are described for extracting ions from atmospheric pressure plasma sources into an analytical mass spectrometer. Methodologies and basic concepts of inductively coupled plasma mass spectrometry (ICP-MS) are emphasized in the discussion, including ion source, sampling interface, supersonic expansion, slumming process, ion optics and beam focusing, and vacuum considerations. Some new developments and innovative designs are introduced. The plasma extraction process in ICP-MS was investigated by Langmuir measurements in the region between the skimmer and first ion lens. Electron temperature (T e ) is in the range 2000--11000 K and changes with probe position inside an aerosol gas flow. Electron density (n e ) is in the range 10 8 --10 10 -cm at the skimmer tip and drops abruptly to 10 6 --10 8 cm -3 near the skimmer tip and drops abruptly to 10 6 --10 8 cm -3 downstream further behind the skimmer. Electron density in the beam leaving the skimmer also depends on water loading and on the presence and mass of matrix elements. Axially resolved distributions of electron number-density and electron temperature were obtained to characterize the ion beam at a variety of plasma operating conditions. The electron density dropped by a factor of 101 along the centerline between the sampler and skimmer cones in the first stage and continued to drop by factors of 10 4 --10 5 downstream of skimmer to the entrance of ion lens. The electron density in the beam expansion behind sampler cone exhibited a 1/z 2 intensity fall-off (z is the axial position). An second beam expansion originated from the skimmer entrance, and the beam flow underwent with another 1/z 2 fall-off behind the skimmer. Skimmer interactions play an important role in plasma extraction in the ICP-MS instrument

  11. SEQUENTIAL EXTRACTION OF PHOSPHORUS BY MEHLICH-1 AND ION EXCHANGE RESIN FROM B HORIZONS OF FERRIC AND PERFERRIC LATOSOLS (OXISOLS

    Directory of Open Access Journals (Sweden)

    Danilo de Lima Camêlo

    2015-08-01

    Full Text Available In general, Latosols have low levels of available P, however, the influence of the parent material seems to be decisive in defining the pool and predominant form of P in these soils. This study evaluated P availability by extraction with Mehlich-1 (M-1 and Ion Exchange Resin (IER, from samples of B horizons of Ferric and Perferric Latosols developed from different parent materials. To this end, in addition to the physical and chemical characterization of soils, 10 sequential extractions were performed with M-1 and IER from samples of B horizons (depth between 0.8 and 1.0 m. Total contents of Ca, P, Fe, Al, and Ti were determined after digestion with nitric, hydrofluoric and perchloric acids. The effects of sequential P extractions on Fe oxides were also evaluated from the analyses of dithionite-citrate-bicarbonate and ammonium acid oxalate. The high similarity between contents of P accumulated after sequential extractions with M-1 and IER in soils developed on tuffite indicated a predominance of P-Ca. Higher contents of P after a single IER extraction show greater efficiency in P removal from highly weathered soils, as from the Latosols studied here. The P contents also show the high sensitivity of extractant M-1 in highly buffered soils. Furthermore, a single extraction with extractant M-1 or IER is not sufficient to estimate the amount of labile P in these soils.

  12. Conditions for minimization of halo particle production during transverse compression of intense ion charge bunches in the Paul Trap Simulator Experiment (PTSX)

    International Nuclear Information System (INIS)

    Gilson, Erik P.; Chung, Moses; Davidson, Ronald C.; Dorf, Mikhail; Efthimion, Philip C.; Grote, David P.; Majeski, Richard; Startsev, Edward A.

    2007-01-01

    The Paul Trap Simulator Experiment (PTSX) is a compact laboratory Paul trap that simulates propagation of a long, thin charged-particle bunch coasting through a multi-kilometer-long magnetic alternating-gradient (AG) transport system by putting the physicist in the frame-of-reference of the beam. The transverse dynamics of particles in both systems are described by the same sets of equations-including all nonlinear space-charge effects. The time-dependent quadrupolar voltages applied to the PTSX confinement electrodes correspond to the axially dependent magnetic fields applied in the AG system. This paper presents the results of experiments in which the amplitude of the applied confining voltage is changed over the course of the experiment in order to transversely compress a beam with an initial depressed tune ν/ν 0 ∼0.9. Both instantaneous and smooth changes are considered. Particular emphasis is placed on determining the conditions that minimize the emittance growth and, generally, the number of particles that are found at large radius (so-called halo particles) after the beam compression. The experimental data are also compared with the results of particle-in-cell (PIC) simulations performed with the WARP code

  13. Synthesis and application of novel ion-imprinted polymer coated magnetic multi-walled carbon nanotubes for selective solid phase extraction of lead(II) ions

    Energy Technology Data Exchange (ETDEWEB)

    Fayazi, Maryam, E-mail: maryam.fayazi@yahoo.com [Mineral Industries Research Center, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Young Researchers Society, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Taher, Mohammad Ali [Department of Chemistry, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Afzali, Daryoush [Department of Environment, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman (Iran, Islamic Republic of); Mostafavi, Ali [Department of Chemistry, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Ghanei-Motlagh, Masoud, E-mail: m.ghaneimotlagh@yahoo.com [Young Researchers Society, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Department of Chemistry, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2016-03-01

    In this study, novel magnetic ion-imprinted polymer (MIIP) nanoparticles were utilized for the sensitive and selective detection of Pb(II) ions by graphite furnace atomic absorption spectrometry (GFAAS). The Pb(II)-imprinted polymer was synthesized by using 4-vinylpyridine (4VP) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, 2,3,5,6-tetra(2-pyridyl) pyrazine (TPPZ) as the chelating agent and magnetic multi-walled carbon nanotubes (MMWCNTs) as the carrier. The synthesized MIIP materials were characterized by field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and vibrating sample magnetometer (VSM). Various analytical parameters such as extraction and desorption time, eluent type and concentration, pH and sample volume were systematically examined. The selectivity of MIIP sorbent for Pb(II) ions in the presence of some cations was also evaluated. The limit of detection (LOD, 3S{sub b}) and the relative standard deviation (RSD, n = 8, c = 25 ng L{sup −1}) were found to be 2.4 ng L{sup −1} and 5.6%, respectively. The maximum sorption capacity of the MIIP for Pb(II) was found to be 48.1 mg g{sup −1}. Finally, the proposed analytical procedure was successfully applied to monitoring lead in human hair and water samples with satisfactory results for the spiked samples. - Highlights: • A selective and sensitive method based on MSPE-GFAAS was proposed. • The MIIP nanoparticles were characterized using FE-SEM, XRD, VSM and FT-IR techniques. • The synthesized MIIP material is efficient at extracting lead ions. • The method was applied to determine lead ions in several real samples.

  14. Calculation of extracted ion beam particle distribution including within-extractor collisions from H-alpha Doppler shift measurements

    International Nuclear Information System (INIS)

    Kim, Tae-Seong; Kim, Jinchoon; In, Sang Ryul; Jeong, Seung Ho

    2008-01-01

    Prototype long pulse ion sources are being developed and tested toward the goal of a deuterium beam extraction of 120 keV/65 A. The latest prototype source consists of a magnetic bucket plasma generator and a four-grid copper accelerator system with multicircular apertures of 568 holes. To measure the angular divergence and the ion species of the ion beam, an optical multichannel analyzer (OMA) system for a Doppler-shifted H-alpha lights was set up at the end of a gas-cell neutralizer. But the OMA data are very difficult to analyze due to a large background level on the top of the three energy peaks (coming from H + , H 2 + , and H 3 + ). These background spectra in the OMA signals seem to result from partially accelerated ion beams in the accelerator. Extracted ions could undergo a premature charge exchange as the accelerator column tends to have a high hydrogen partial pressure from the unused gas from the plasma generator, resulting in a continuous background of partially accelerated beam particles at the accelerator exit. This effect is calculated by accounting for all the possible atomic collision processes and numerically summing up three ion species across the accelerator column. The collection of all the atomic reaction cross sections and the numerical summing up will be presented. The result considerably depends on the background pressure and the ion beam species ratio (H + , H 2 + , and H 3 + ). This effect constitutes more than 20% of the whole particle distribution. And the energy distribution of those suffering from collisions is broad and shows a broad maximum in the vicinity of the half and the third energy region

  15. Feasibility of corona discharge ion mobility spectrometry for direct analysis of samples extracted by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Jafari, Mohammad T; Riahi, Farhad

    2014-05-23

    The capability of corona discharge ionization ion mobility spectrometry (CD-IMS) for direct analysis of the samples extracted by dispersive liquid-liquid microextraction (DLLME) was investigated and evaluated, for the first time. To that end, an appropriate new injection port was designed and constructed, resulting in possibility of direct injection of the known sample volume, without tedious sample preparation steps (e.g. derivatization, solvent evaporation, and re-solving in another solvent…). Malathion as a test compound was extracted from different matrices by a rapid and convenient DLLME method. The positive ion mobility spectra of the extracted malathion were obtained after direct injection of carbon tetrachloride or methanol solutions. The analyte responses were compared and the statistical results revealed the feasibility of direct analysis of the extracted samples in carbon tetrachloride, resulting in a convenient methodology. The coupled method of DLLME-CD-IMS was exhaustively validated in terms of sensitivity, dynamic range, recovery, and enrichment factor. Finally, various real samples of apple, river and underground water were analyzed, all verifying the feasibility and success of the proposed method for the easy extraction of the analyte using DLLME separation before the direct analysis by CD-IMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Yield And Transverse Momentum Of Relativistic Hydrogen Isotopes In Photonuclear Spallation Of 32S Ions At 200A GeV

    International Nuclear Information System (INIS)

    Abdelsalam, A.; Kamel, S.; Abdel-Waged, Kh.; Fashed, N.

    2005-01-01

    Production of multi-hydrogen (mH) isotopes in the spallation of 200A GeV sulphur projectile using nuclear emulsion is reported. Yield of mH isotopes is studied and compared with that of the lowest energy (3.7A GeV) data. The two-source emission picture is used to describe the transverse momentum (P T ) distribution of mH isotopes (with and without the effect of 32 S (γ,p) 31 P channel). The Rayleigh type P T -distribution seems to be in agreement with the corresponding experimental data. The contributions of low and high temperature emission sources show a dependence on the photonuclear processes. (author)

  17. Solvent extraction of titanium(IV), zirconium(IV) and hafnium(IV) salicylates using liquid ion exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Sundaramurthi, N M; Shinde, V M

    1989-02-01

    A solvent extraction method is proposed for the extraction of quadrivalent titanium, zirconium an hafnium from salicylate media using liquid ion exchangers such as Aliquat 336 and trioctylamine dissolved in xylene. The optimum conditions were evaluated from a critical study of the following: pH, salicylate concentration, amine concentration, diluent and period of equilibration. The method allows the separation of titanium, zirconium and hafnium from binary mixtures containing commonly associated metal ions and is applicable to the analysis of real samples such as BCS-CRM 387 nimonic 901, BCS-CRM 243/4 ferro-titanium, BCS-CRM 307 magnesium alloy and BCS-CRM 388 zircon. Titanium is determined either with hydrogen peroxide or by atomic absorption spectrometry whereas zirconium and hafnium are determined spectrophotometrically with Alizarin Red S and Zylenol Orange, respectively. The results of both separation and analysis are reported. The method is precise, accurate and fast.

  18. Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packed-bed columns

    International Nuclear Information System (INIS)

    Ersoez, Arzu; Say, Ridvan; Denizli, Adil

    2004-01-01

    Solid-phase extraction (SPE) columns packed with materials based on molecularly imprinted polymers (MIPs) were used to develop selective separation and preconcentration for Ni(II) ion from aqueous solutions. SPE is more rapid, simple and economical method than the traditional liquid-liquid extraction. MIPs were used as column sorbent to increase the grade of selectivity in SPE columns. In this study, we have developed a polymer obtained by imprinting with Ni(II) ion as a ion-imprinted SPE sorbent. For this purpose, NI(II)-methacryloylhistidinedihydrate (MAH/Ni(II)) complex monomer was synthesized and polymerized with cross-linking ethyleneglycoldimethacrylate to obtain [poly(EGDMA-MAH/Ni(II))]. Then, Ni(II) ions were removed from the polymer getting Ni(II) ion-imprinted sorbent. The MIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.3 to 25 ng/ml and the detection limit was 0.3 ng/ml (3 s) for flame atomic absorption spectrometry (FAAS). Ni(II) ion-imprinted microbeads can be used several times without considerable loss of adsorption capacity. When the adsorption capacity of nickel imprinted microbeads were compared with non-imprinted microbeads, nickel imprinted microbeads have higher adsorption capacity. The K d (distribution coefficient) values for the Ni(II)-imprinted microbeads show increase in K d for Ni(II) with respect to both K d values of Zn(II), Cu(II) and Co(II) ions and non-imprinted polymer. During that time K d decreases for Zn(II), Cu(II) and Co(II) ions and the k' (relative selectivity coefficient) values which are greater than 1 for imprinted microbeads of Ni(II)/Cu(II), Ni(II)/Zn(II) and Ni(II)/Co(II) are 57.3, 53.9, and 17.3, respectively. Determination of Ni(II) ion in sea water showed that the interfering matrix had been almost removed during preconcentration. The column was good enough for Ni determination in matrixes containing similar ionic radii ions such as Cu(II), Zn(II) and Co(II)

  19. Extraction-radiochemical study of the ion-association complex of antimony (V) with tetrazolium violet and its thermal behavior

    International Nuclear Information System (INIS)

    Kostova, S.G.; Boyanov, B.S.

    1995-01-01

    The optimum conditions for extraction of ion-associated complexes (IAS) formed from the tetrazolium salt - tetrazolium violet and Sb(V) in hydrochloric acid medium have been studied. An isotope of antimony ( 125 Sb) was used for determination of the recovery factor (R%) and distribution ratio (D S b). The thermal behavior of the antimony complex with tetrazole violet was studied using differential thermal and thermogravimetric analysis. (author) 12 refs.; 3 figs

  20. Synthesis of organic motif tailored hybrid nanoframes: Exploiting in vitro bioactivity and heavy metal ion extraction applications

    Energy Technology Data Exchange (ETDEWEB)

    Tayade, Kundan C. [School of Environmental and Earth Sciences, North Maharashtra University, Jalgaon, MS (India); Kuwar, Anil S. [School of Chemical Sciences, North Maharashtra University, Jalgaon, MS (India); Ingle, Sopan T. [School of Environmental and Earth Sciences, North Maharashtra University, Jalgaon, MS (India); Attarde, Sanjay B., E-mail: sb.attarde@yahoo.co.in [School of Environmental and Earth Sciences, North Maharashtra University, Jalgaon, MS (India)

    2017-02-15

    Hybrid nanoparticles (NPs) were designed by adsorbing a (13E,19E)-N{sub 1}′,N{sub 3}′-bis[4-(diethylamino)-2-hydroxybenzylidene]malonohydrazide (L) motif, on Fe{sub 3}O{sub 4}@SiO{sub 2} distorted hexagonal and cubic NPs. Electronic images of the synthesized hybrid NPs revealed distorted topographies with size of ∼50–70 nm. We exploited key in vitro features, topographies, thermal behaviours, spectroscopic data, magnetic properties and heavy metal ion extraction efficiencies of the prepared hybrids. Additionally, the discrete discussion on the surface areas of the synthesized NPs tackled with BET, are introduced. Characterization with FT-IR, SEM, TEM, XRD, BET, VSM, TGA, particle size analysis and Raman spectroscopic techniques revealed that the organic scaffold L is attached to the prepared Fe{sub 3}O{sub 4}@SiO{sub 2} NPs surface via adsorption or covalent interactions or some sort of charge/proton transfer. Antibacterial tests depicted that, L and Fe{sub 3}O{sub 4}@SiO{sub 2} NPs exhibited moderate to good antifungal activity against C. albicans, while synthesized key hybrids has shown good to high antibacterial activity against Gram-positive bacterium, S. aureus, two Gram-negative bacteria's, E. coli and P. aeruginosa, and antifungal activity against C. albicans. Also, the Zn{sup 2+} ion extraction efficiency of the key hybrids was tackled and validated with commercial pharmaceutical tablet analysis. - Highlights: • New hybrid nanoparticles (NPs) shown good to high antibacterial activity. • NPs showed barely compromised magnetism and thermal stability. • Macroporous NPs depicted harmonious Zn(II) ion extraction efficiency. • Extraction of Zn(II) ions by NPs exhibited no matrix interference.

  1. Synergistic extraction of Eu(III) with N-phosphorylated bis-ureas and chlorinated cobalt bis(dicarbollide) ion

    Czech Academy of Sciences Publication Activity Database

    Selucký, P.; Bubeníková, M.; Rais, J.; Grüner, Bohumír; Brusko, V.V.

    2013-01-01

    Roč. 101, č. 1 (2013), s. 27-31 ISSN 0033-8230 R&D Projects: GA ČR GA104/09/0668 Institutional support: RVO:61388980 Keywords : liquid-liquid extraction * lanthanides * actinides * N-phosphorylated bis-ureas * chlorinated cobalt bis(dicarbollide) ion * high level liquid waste Subject RIV: CA - Inorganic Chemistry Impact factor: 1.411, year: 2013

  2. A simple liquid extraction protocol for overcoming the ion suppression of triacylglycerols by phospholipids in liquid chromatography mass spectrometry studies.

    Science.gov (United States)

    Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu

    2016-02-01

    It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Scaling properties of the transverse mass spectra

    International Nuclear Information System (INIS)

    Schaffner-Bielich, J.

    2002-01-01

    Motivated from the formation of an initial state of gluon-saturated matter, we discuss scaling relations for the transverse mass spectra at BNL's relativistic heavy-ion collider (RHIC). We show on linear plots, that the transverse mass spectra for various hadrons can be described by an universal function in m t . The transverse mass spectra for different centralities can be rescaled into each other. Finally, we demonstrate that m t -scaling is also present in proton-antiproton collider data and compare it to m t -scaling at RHIC. (orig.)

  4. IonLab. A remote-controlled experiment for academic and vocational education and training on extraction chromatography and ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Wolfgang; Fournier, Claudia; Vahlbruch, Jan-Willem; Walther, Clemens [Leibniz Univ., Hannover (Germany). Inst. for Radioecology and Radiation Protection (IRS)

    2016-07-01

    As a major contribution to modern web-based education and training in nuclear chemistry we have built and operated a remote-controlled experiment - IonLab - as part of the integrated EUFP7 project CINCHII. The setup is suitable for teaching basics on extraction chromatography and ion exchange using radionuclides. We describe separation of the beta emitting nuclides Sr-90 and Y-90 followed by radiometric detection, but the experiment is easily adapted to other separation schemes. This approach is aimed at institutions in academic or vocational education who need to convey the skills of handling radioactive (or otherwise dangerous, e.g. biotoxic) substances without appropriately licensed laboratory space for teaching. This camera-monitored remote controlled lab experiment has proved to be much closer to a real hands-on training and superior to a mere computer simulation.

  5. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    Science.gov (United States)

    Brombin, M.; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R.; Schiesko, L.

    2014-11-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors' holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

  6. Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

    International Nuclear Information System (INIS)

    Brombin, M.; Spolaore, M.; Serianni, G.; Pomaro, N.; Taliercio, C.; Palma, M. Dalla; Pasqualotto, R.; Schiesko, L.

    2014-01-01

    A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns

  7. Simultaneous spectrophotometric determination of trace copper, nickel, and cobalt ions in water samples using solid phase extraction coupled with partial least squares approaches

    Science.gov (United States)

    Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui

    2017-02-01

    A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu2 +), cobalt ions (Co2 +) and nickel ions (Ni2 +) mixture was 0.10 μg L- 1, 0.15 μg L- 1 and 0.13 μg L- 1, respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field.

  8. Recent progress of task-specific ionic liquids in chiral resolution and extraction of biological samples and metal ions.

    Science.gov (United States)

    Wu, Datong; Cai, Pengfei; Zhao, Xiaoyong; Kong, Yong; Pan, Yuanjiang

    2018-01-01

    Ionic liquids have been functionalized for modern applications. The functional ionic liquids are also called task-specific ionic liquids. Various task-specific ionic liquids with certain groups have been constructed and exploited widely in the field of separation. To take advantage of their properties in separation science, task-specific ionic liquids are generally used in techniques such as liquid-liquid extraction, solid-phase extraction, gas chromatography, high-performance liquid chromatography, and capillary electrophoresis. This review mainly covers original research papers published in the last five years, and we will focus on task-specific ionic liquids as the chiral selectors in chiral resolution and as extractant or sensor for biological samples and metal ion purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Liquid-liquid extraction of uranium(VI) with cryptand-222 and Eosin as the counter ion

    International Nuclear Information System (INIS)

    Viji Jacob Mathew; Khopkar, S.M.

    1995-01-01

    Uranium(VI), (5 μg) was quantitatively extracted at pH 6.0 with 0.01M cryptand-222 in chloroform in the presence of 0.005M Eosin as the counter ion. The metal from the organic phase was stripped with 0.1M perchloric acid. Uranium(VI) from the aqueous phase was determined spectrophotometrically at 430 nm as its complex with oxine. The extraction was quantitative between pH 5.5-6.5. Nitrobenzene, chloroform and dichloromethane were the best diluents. The optimum extractant concentration was 0.01M, while that of Eosin was 0.005M. Except for perchloric acid (0.01M), other acids could not strip uranium. Uranium was separated from manganese, cadmium, lead, thallium and nickel, etc., in the multicomponent mixtures. The relative standard deviation was ±1%. (author). 18 refs., 1 fig., 6 tabs

  10. Optimization of LiCoO2 powder extraction process from cathodes of lithium-ion batteries by chemical dissolution

    Directory of Open Access Journals (Sweden)

    Lucas Evangelista Sita

    2015-05-01

    Full Text Available A chemical process has been applied to extract LiCoO2 powder from cathodes of spent lithium-ion batteries by dissolution of the binder that agglutinate the powder particle each other as well to the Al collector surface. As solvents dimethylformamide (DMF and N-methyilpirrolidone (NMP were employed and the variables, cathode area, solution temperature, ultrasound bath power and solution stirring were chosen to optimize the extraction process. NMP solutions presented best results for powder extraction than DMF solutions. At 100 oC and under mechanical stirring or low power ultrasound bath NMP solution optimizes the binder dissolution. Powder extractions under DMF solutions are slow and an increase in the powder extraction efficiency was observed for crushed cathodes on solutions under ultrasound bath, at medium power. Filtration processes can separate the decanted LiCoO2 powder extracted upon DMF dissolution while the powder in suspension in the NMP solutions is separated by centrifugation techniques.

  11. Study of ion suppression for phenolic compounds in medicinal plant extracts using liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Faccin, H; Viana, C; do Nascimento, P C; Bohrer, D; de Carvalho, L M

    2016-01-04

    A systematic study on the various sources of ion suppression in UHPLC-MS-MS analysis was carried out for 24 phenolic antioxidants in 6 different extracts of medicinal plants from Amazonia. The contributions of matrix effects, mobile-phase additives, analyte co-elution and electric charge competition during ionization to the global ion suppression were evaluated. Herein, the influence of mobile-phase additives on the ionization efficiency was found to be very pronounced, where ion suppression of approximately 90% and ion enhancement effects greater than 400% could be observed. The negative effect caused by the wrong choice of internal standard (IS) on quantitative studies was also evaluated and discussed from the perspective of ion suppression. This work also shows the importance of performing studies with this approach even for very similar matrices, such as varieties of medicinal plants from the same species, because different effects were observed for the same analyte. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Development of a high-current ion source with slit beam extraction for neutral beam injector of VEST

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Bong-ki; Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr; An, Young-Hwa; Park, Jong-Yoon; Hwang, Y.S.

    2015-10-15

    Highlights: • A high-current ion source is developed for NBI system of VEST. • A cold-cathode electron gun is employed to produce primary electrons. • A hemi-cylindrical discharge chamber with cusp magnetic field is used. • Plasma density is measured to be 2 × 10{sup 18} m{sup −3} near the extraction aperture. • NBI power of 90 kW with beam energy of 20 keV is expected to be achieved. - Abstract: A high-current pulsed ion source has been developed for the neutral beam injector of the VEST (Versatile Experiment Spherical Torus) to accommodate high-beta fusion plasma experiments. The ion source consists of two parts: an electron gun for supplying sufficient primary electrons by cold-cathode arc discharge and a hemi-cylindrical discharge chamber where uniform, high-density plasma generated by the primary electrons is confined by multi-cusp magnetic field. A pulse forming network is also developed to drive high current of ∼1 kA to sustain the cold-cathode discharge in the electron gun up to 10 ms. Diagnostics with a triple probe in the discharge chamber shows that a hydrogen plasma whose density is as high as 1 × 10{sup 18} m{sup −3} can be obtained near extraction slits at the gas pressure lower than 0.5 Pa. This value is estimated to be sufficient to deposit a heating power of 90 kW to the VEST plasma when the appropriate extraction through slits with 20 cm{sup 2} in area and acceleration of ion beams up to 20 kV are fulfilled.

  13. Selective extraction of americium(III) over europium(III) ions with pyridylpyrazole ligands. Structure-property relationships

    Energy Technology Data Exchange (ETDEWEB)

    Su, Dongping; Liu, Ying; Li, Shimeng; Ding, Songdong; Jin, Yongdong; Wang, Zhipeng; Hu, Xiaoyang; Zhang, Lirong [Department of chemistry, Sichuan University, Chengdu (China)

    2017-01-18

    To clarify the structure-property relationships of pyridylpyrazole ligands and provide guidance for the design of new and more efficient ligands for the selective extraction of actinides over lanthanides, a series of alkyl-substituted pyridylpyrazole ligands with different branched chains at different positions of the pyrazole ring were synthesized. Extraction experiments showed that the pyridylpyrazole ligands exhibited good selective extraction abilities for Am{sup III} ions, and the steric effects of the branched chain had a significant impact on the distribution ratios of Am{sup III} and Eu{sup III} ions as well as the separation factor. Moreover, both slope analyses and UV/Vis spectrometry titrations indicated the formation of a 1:1 complex of 2-(1-octyl-1H-pyrazol-3-yl)pyridine (C8-PypzH) with Eu{sup III} ions. The stability constant (log K) for this complex obtained from the UV/Vis titration was 4.45 ± 0.04. Single crystals of the complexes of 3-(2-pyridyl)pyrazole (PypzH) with Eu(NO{sub 3}){sub 3} and Sm(NO{sub 3}){sub 3} were obtained; PypzH acts as a bidentate ligand in the crystal structures, and the N atom with a bound H atom did not participate in the coordination. In general, this study revealed some interesting findings on the effects of the alkyl-chain structure and the special complexation between pyridylpyrazole ligands and Ln{sup III} ions. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. Transverse electron resonance accelerator

    International Nuclear Information System (INIS)

    Osonka, P.L.

    1985-01-01

    Transverse (to the velocity, v-bar, of the particles to be accelerated) electron oscillations are generated in high (e.g. solid) density plasms by either an electromagnetic wave or by the field of charged particles traveling parallel to v-bar. The generating field oscillates with frequency ω = ω/sub p/, where ω/sub p/ is the plasma frequency. The plasma is confined to a sequence of microstructures with typical dimensions of d≅2πc/ω/sub p/, allowing the generating fields to penetrate. Since ω/sub p/ is now high, the time scales, T, are correspondingly reduced. The microstructures are allowed to explode after t = T, until then they are confined by ion inertia. As a result of resonance, the electric field, E, inside the microstructures can exceed the generating field E/sub L/. The generating force is proportional to E/sub L/ (as opposed to E 2 /sub L/). Phase matching of particles is possible by appropriate spacing of the microstructures or by a gas medium. The generating beam travels outside the plasma, filamentation is not a problem. The mechanism is relatively insensitive to the exact shape and position of the microstructures. This device contains features of various earlier proposed acceleration mechanisms and may be considered as the limiting case of several of those for small d, T and high E

  15. Transverse electron resonance accelerator

    International Nuclear Information System (INIS)

    Csonka, P.L.

    1985-01-01

    Transverse (to the velocity, v, of the particles to be accelerated) electron oscillations are generated in high (e.g. solid) density plasmas by either an electromagnetic wave or by the field of charged particles traveling parallel to v. The generating field oscillates with frequency ω = ω/sub p/, where ω/sub p/ is the plasma frequency. The plasma is confined to a sequence of microstructures with typical dimensions of d approx. = 2πc/ω/sub p/, allowing the generating fields to penetrate. Since ω/sub p/ is now high, the time scales, T, are correspondingly reduced. The microstructures are allowed to explode after t = T, until then they are confined by ion inertia. As a result of resonance, the electric field, E, inside the microstructures can exceed the generating field E/sub L/. The generating force is proportional to E/sub L/ (as opposed to E/sub L/ 2 ). Phase matching of particles is possible by appropriate spacing of the microstructures or by a gas medium. The generating beam travels outside the plasma, filamentation is not a problem. The mechanism is relatively insensitive to the exact shape and position of the microstructures. This device contains features of various earlier proposed acceleration mechanisms and may be considered as the limiting case of several of those for small d, T and high E

  16. Chemically-modified activated carbon with ethylenediamine for selective solid-phase extraction and preconcentration of metal ions.

    Science.gov (United States)

    Li, Zhenhua; Chang, Xijun; Zou, Xiaojun; Zhu, Xiangbing; Nie, Rong; Hu, Zheng; Li, Ruijun

    2009-01-26

    A new method that utilizes ethylenediamine-modified activated carbon (AC-EDA) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The new sorbent was prepared by oxidative surface modification. Experimental conditions for effective adsorption of trace levels of Cr(III), Fe(III), Hg(II) and Pb(II) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4.0. Complete elution of absorbed metal ions from the sorbent surface was carried out using 3.0 mL of 2% (%w/w) thiourea and 0.5 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.4, 28.9, 60.5 and 49.9 mg g(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The time for 94% adsorption of target metal ions was less than 2 min. The detection limits of the method was found to be 0.28, 0.22, 0.09 and 0.17 ng mL(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The precision (R.S.D.) of the method was lower 4.0% (n=8). The prepared sorbent as solid-phase extractant was successfully applied for the preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) in natural and certified samples with satisfactory results.

  17. Aggregation of dialkyl-substituted diphosphonic acids and its effect on metal ion extraction.

    Energy Technology Data Exchange (ETDEWEB)

    Chiarizia, R.; Barrans, R. E., Jr.; Ferraro, J. R. Herlinger, A. W.; McAlister, D. R.

    1999-10-22

    Solvent extraction reagents containing the diphosphonic acid group exhibit an extraordinary affinity for tri-, tetra- and hexavalent actinides. Their use has been considered for actinide separation and pre-concentration procedures. Solvent extraction data obtained with P,P{prime}-di(2-ethylhexyl) methane-, ethane- and butanediphosphonic acids exhibit features that are difficult to explain without Knowledge of the aggregation state of the extractants. Information about the aggregation of the dialkyl-substituted diphosphonic acids in aromatic diluents has been obtained using the complementary techniques of vapor pressure osmometry (VPO), small angle neutron scattering (SANS), infrared spectroscopy and molecular mechanics. The results from these techniques provide an understanding of the aggregation behavior of these extractants that is fully compatible with the solvent extraction data. The most important results and their relevance to solvent extraction are reviewed in this paper.

  18. Transverse emittance measurement of high-current single pulse beams using pepper-pot method

    International Nuclear Information System (INIS)

    Ke Jianlin; Zhou Changgeng; Qiu Rui

    2013-01-01

    A pepper pot-imaging plate system has been developed and used to measure the 4-D transverse emittance of a vacuum arc ion source. Single beam pulses of tens to hundreds milliamperes were extracted from the plasma with 64 kV high voltage. An imaging plate was laid after the pepper pot to visualize the ion beamlets passing though the holes on the pepper pot. An application program was developed to show the phase-space distribution and calculate the ellipse and RMS emittances. The normalized RMS emittances are about 6.41 π·mm·mrad in x-direction and 4.61 π·mm·mrad in y-direction. It is shown that the emittance of the vacuum arc ion source is much larger than that of other types of ion sources, which is mainly attributed to the high current and the convex meniscus of this source. (authors)

  19. Preconcentration and determination of zinc and lead ions by a combination of cloud point extraction and flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tavallali, H. [Chemistry Department, Payamenore University, Shiraz (Iran); Shokrollahi, A.; Zahedi, M. [Chemistry Department, Yasouj University, Yasouj (Iran); Niknam, K. [Chemistry Department, Persian Gulf University, Bushehr (Iran); Soylak, M. [Chemistry Department, University of Erciyes, Kayseri (Turkey); Ghaedi, M.

    2009-04-15

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of lead(II) and zinc(II). After complexation with 3-[(4-bromophenyl) (1-H-inden-3-yl)methyl]-1 H-indene (BPIMI), the analytes were quantitatively extracted to a phase rich in Triton X-114 after centrifugation. Methanol acidified with 1 mol/L HNO{sub 3} was added to the surfactant rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The concentration of bis((1H-benzo [d] imidazol-2yl)ethyl)sulfane, Triton X-114, pH and amount of surfactant were all optimized. Detection limits (3 SDb/m) of 2.5 and 1.6 ng/mL for Pb{sup 2+} and Zn{sup 2+} along with preconcentration factors of 30 and an enrichment factor of 32 and 48 for Pb{sup 2+}and Zn {sup 2+} ions were obtained, respectively. The proposed cloud point extraction was been successfully applied for the determination of these ions in real samples with complicated matrices such as food and soil samples, with high efficiency. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  20. Spherical agarose-coated magnetic nanoparticles functionalized with a new salen for magnetic solid-phase extraction of uranyl ion

    International Nuclear Information System (INIS)

    Serenjeh, Fariba Nazari; Hashemi, Payman; Ghiasvand, Ali Reza; Naeimi, Hossein; Zakerzadeh, Elham

    2016-01-01

    The authors describe a method for magnetic solid phase extraction of uranyl ions from water samples. It is based on the use of spherical agarose-coated magnetic nanoparticles along with magnetic field agitation. The salen type Schiff base N,N’-bis(4-hydroxysalicylidene)-1,2-phenylenediamine was synthesized from resorcinol in two steps and characterized by infrared and nucleic magnetic resonance spectroscopies. The particles were then activated by an epichlorohydrin method and functionalized with the Schiff base which acts as a selective ligand for the extraction of UO 2 (II). Following preconcentration and elution with HCl, the ions were quantified by spectrophotometry using Arsenazo III as the indicator. The effects of pH value, ionic strength and amount of the adsorbent on the extraction of UO 2 (II) were optimized by a multivariate central composite design method. Six replicate analyses under optimized conditions resulted in a recovery of 96.6 % with a relative standard deviation of 3.4 % for UO 2 (II). The detection limit of the method (at a signal-to-noise ratio of 3σ) is 10 μg L -1 . The method was successfully applied to the determination of UO 2 (II) in spiked water samples. (author)

  1. Extraction and ion exchange equilibrium. A study by means logarith-mic diagrams

    International Nuclear Information System (INIS)

    Vicente Perez, S.; Alvarez, M.D.; Durand, S.

    1990-01-01

    A general logarithmic mole fraction diagram for the study of distribution equilibria of a) a neutral chemical species between two inmiscible solvents and b) and ionic species between an aqueous phase and ion-exchange resin, is proposed. (Author)

  2. Determination of metastable fraction in an ion beam extracted from ECR plasma

    International Nuclear Information System (INIS)

    Matsumoto, Atsushi; Ohtani, Shunsuke; Iwai, Tsuruji.

    1982-04-01

    The fraction of metastable-state Ar 2 + (3p 4 1 D) ions in Ar 2 + beam has been determined by an optical attenuation method (OAM) combined with the conventional beam attenuation method. The present OAM is based on observation of spatial decay of specified emission line intensities arising from charge-changed ions, along the beam axis in a target gas cell. The validity of the OAM is discussed in detail. The cross sections for one-electron capture by the ground-state Ar 2 + ( 3 P) ions, σ 21 , and by the metastable-state Ar 2 + ( 1 D) ions, σ 21 *, from Na have been measured independently by the OAM. Both the cross sections are of the order of 10 - 14 cm 2 and σ 21 * is about 1.3 times as large as σ 21 at the collision energy of 1.5 keV. (author)

  3. Ionizable polyethers as specific metal ion carriers in liquid-liquid extraction and liquid membrane separations

    International Nuclear Information System (INIS)

    Walkowiak, W.; Charewicz, W.A.; Bartsch, R.A.; Ndip, G.M.

    1988-01-01

    Consideration is given to results of investigations into competitive extraction and penetration through a liquid membrane of alkali and alkaline earth cations from aqueous solutions by a series of lipophilic and ionizable acyclic polyethers of various molecular structure. It is shown that specificity and selectiviy of cation carriers in liquid-liquid extraction and liquid membrane separation depend on molecular structure of acyclic polyethers

  4. Mathematical simulation and calculation of the continuous countercurrent process of ion-exchange extraction of strontium from strongly mineralized solutions

    International Nuclear Information System (INIS)

    Nikashina, V.A.; Guryanova, L.N.; Baturova, L.L.; Venetsianov, E.V.; Ivanov, V.A.; Nikolaev, N.P.

    1993-01-01

    The program open-quotes Countercurrentclose quotes is developed for the simulation of a continuous ion-exchange extraction of strontium from strongly mineralized NaCl and CaCl 2 solutions using a KB-4 carboxylic cation-exchanger in the countercurrent columns. The program allows one to Calculate the conditions of Ca and Sr separation depending on the mode of operation at the sorption and regeneration stages, the residual Sr content on the overloaded sorbent, and the Sr separation on incompletely regenerated KB-4. It also makes it possible to find the optimal separation conditions. The program open-quotes Countercurrentclose quotes can be also used to simulate other ion-exchange processes

  5. Chapter 6. Uranium extraction possibilities from natural uranium-bearing waters of complex salt composition. 6.2. Technology for uranium extraction from brine with a high content of ion-chlorine

    International Nuclear Information System (INIS)

    Khakimov, N.; Nazarov, Kh.M.; Mirsaidov, I.U.

    2012-01-01

    Present article is devoted to technology for uranium extraction from brine with a high content of ion-chlorine. The content of basic anions and cations in lake waters of Sasik-Kul deposit was defined. Results of X-ray spectral analysis of salt residual after water evaporation from Sasik-Kul lake was discussed. Investigations revealed that uranium extraction from brines containing ion-chlorine is possible. The developed basic process flow diagram of uranium extraction from Sasik-Kul Lake' brine consists of the following basic stages: evaporation, leaching, catching of formed gases (HCl), sorption, desorption, deposition, drying and tempering.

  6. Chapter 6. Uranium extraction possibilities from natural uranium-bearing waters of complex salt composition. 6.2. Technology for uranium extraction from brine with a high content of ion-chlorine

    International Nuclear Information System (INIS)

    Khakimov, N.; Nazarov, Kh.M.; Mirsaidov, I.U.

    2011-01-01

    Present article is devoted to technology for uranium extraction from brine with a high content of ion-chlorine. The content of basic anions and cations in lake waters of Sasik-Kul deposit was defined. Results of X-ray spectral analysis of salt residual after water evaporation from Sasik-Kul lake was discussed. Investigations revealed that uranium extraction from brines containing ion-chlorine is possible. The developed basic process flow diagram of uranium extraction from Sasik-Kul Lake' brine consists of the following basic stages: evaporation, leaching, catching of formed gases (HCl), sorption, desorption, deposition, drying and tempering.

  7. Solvent extraction of europium(III) with benzoylacetone and benzoyltrifluoroacetone into carbon tetrachloride in the absence and presence of tetrabutylammonium ions

    International Nuclear Information System (INIS)

    Noro, Junji; Sekine, Tatsuya.

    1992-01-01

    The solvent extraction of europium (III) in 0.1 mol dm -3 sodium nitrate solutions with benzoylacetone (Hbza) or benzoyltrifluoroacetone (Hbfa) in carbon tetrachloride was measured in the absence and presence or tetrabutylammonium ions (tba + ). Although extraction with Hbfa occurred at lower pH than with Hbza, the extraction measured as a function of the β-diketonate ion concentration in the aqueous phase was rather similar. It was also found that extraction with Hbfa was greatly enhanced by the addition of tba + , the effect, however, was negligible with Hbza. The data were analyzed from the stand point that the neutral metal chelate, Eu(bfa) 3 , was extracted into the organic phase and associated with ion-pairs of the reagents, bfa - tba + , in this phase. It was also found that though extraction of ion-pairs of bfa - tba + occurred, that of bza - tba + was negligible. Thus, the reason for the negligible extraction of the ternary complex, Eu (bza) 4 - tba + , was explained in terms of the negligible extraction of the bza - tba + , which might associate with Eu(bza) 3 in the organic phase. (author)

  8. Dispersive solid phase extraction combined with ion-pair ultra high-performance liquid chromatography tandem mass spectrometry for quantification of nucleotides in Lactococcus lactis

    DEFF Research Database (Denmark)

    Magdenoska, Olivera; Martinussen, Jan; Thykær, Jette

    2013-01-01

    solid phase extraction with charcoal and subsequent analysis with ion-pair liquid chromatography coupled with electrospray ionization tandem mass spectrometry was established for quantification of intracellular pools of the 28 most important nucleotides. The method can handle extracts where cells leak...

  9. Removal of Radioactive Nuclides by Multi-Functional Microcapsules Enclosing Inorganic Ion-Exchangers and Organic Extractants

    Energy Technology Data Exchange (ETDEWEB)

    Mimura, H.; Akiba, K.; Onodera, Y.

    2002-02-26

    The microcapsules enclosing two kinds of functional materials, inorganic ion-exchangers and organic extractants, were prepared by taking advantage of the high immobilization ability of alginate gel polymer. The fine powders of inorganic ion-exchanger and oil drops of extractant were kneaded with sodium alginate (NaALG) solution and the kneaded sol readily gelled in a salt solution of CaCl2, BaCl2 or HCl to form spherical gel particles. The uptake properties of various nuclides, 137Cs, 85Sr, 60Co, 88Y, 152Eu and 241Am, for thirty-four specimens of microcapsules in the presence of 10-1-10-4 M HNO3 were evaluated by the batch method. The distribution coefficient (Kd) of Cs+ above 103 cm3/g was obtained for the microcapsules enclosing CuFC or AMP. The Kd of Sr2+ around 102 cm3/g was obtained for the microcapsules containing clinoptilolite, antimonic acid, zeolite A, zeolite X or titanic acid. The microcapsules enclosing DEHPA exhibited relatively large Kd values of trivalent metal ions above 103 cm3/g; for example, the Kd values of Cs+, Sr2+, Co2+, Y3+, Eu3+ and Am3+ for a favorable microcapsule (CuFC/clinoptilolite/DEHPA/CaALG) were 1.1x104, 7.5x10, 1.1x10, 1.0x104, 1.4x104, 3.4x103 cm3/g, respectively. The uptake rates of Cs+, Y3+, Eu3+ and Am3+ for this microcapsule were rather fast; the uptake percentage above 90% was obtained after 19 h-shaking and the uptake equilibrium was attained within 1 d. The AMP/CaALG exhibited high uptake ability for Cs+ even after irradiation of 188 kGy, and DEHPA/CaALG microcapsule had similar Kd values of Cs+, Sr2+, Co2+, Y3+, Eu3+ and Am3+ ions before and after irradiation. The microcapsules with various shapes such as spherical, columnar, fibrous and filmy forms were easily prepared by changing the way of dipping kneaded sol into gelling salt solution. The microcapsules enclosing inorganic ion-exchangers and extractants have a potential possibility for the simultaneous removal of various radioactive nuclides from waste solutions.

  10. THERMOLYSIS OF FOAM PRODUCTS FORMED AT THE FLOTATION EXTRACTION OF COPPER AND NICKEL IONS BY HELP OF WAX PEAT

    Directory of Open Access Journals (Sweden)

    V. F. Sazonova

    2015-02-01

    Full Text Available There thermogravimetric study of foam product at the flotation extraction of cop­per and nickel ions by wax peat results are described. It shown that oxidizing roasting of foam products (i.e. hydrated soaps of polyvalent metals proceeds in several steps. At the first step (t<100 °С dehydration takes place. At the next ones (t=160^665 °С The thermic destruction and burning of organic compounds occurs. The residue is the of metal oxides.

  11. Mathematical simulation and calculation of continuous countercurrent process of ion-exchange extraction of strontium from strongly mineralized solutions

    International Nuclear Information System (INIS)

    Nikashina, V.A.; Venitsianov, E.V.; Ivanov, V.A.; Gur'yanova, L.N.; Nikolaev, N.P.; Baturova, L.L.; Moskovskij Gosudarstvennyj Univ., Moscow

    1993-01-01

    A program 'Countercurrent' is developed for the simulation of a continuous ion-exchange extraction of strontium from the strongly mineralized solutions containing NaCl and CaCl 2 using carboxylic cation exchanger KB-4 in countercurrent columns. The use of the program allows one to calculate the consitions of Ca and Sr separation depending on the modes of operation at the stage of sorption as well as regeneration, to calculate a residual Sr content on an overloaded sorbent and Sr separation on an incompletely regenerated KB-4, and to find the optimal separation conditions

  12. Determination of the extractive capacity of para-tert butyl calix[8]arene octa-phosphinoylated towards uranyl ions from an aqueous-acidic-salty medium

    International Nuclear Information System (INIS)

    Serrano V, E. C.

    2011-01-01

    The extraction properties of octa-phosphinoylated para-tert butyl calix[8]arene (prepared in the laboratory) in chloroform towards uranyl ions from an aqueous-acidic-salty medium (HNO 3 -3.5 NaNO 3 ) containing uranyl nitrate salt, was investigated. Two spectroscopic techniques UV/Vis and Luminescence were used for this study. The latter permitted analyze the fluorescence from the uranyl ions influenced by the surrounding medium. Both permitted to learn about the power of this calixarene as extractant towards the mentioned ions. Its extraction ability or capability using this calixarene at 5.91 x 10 -4 M towards the uranyl ions was 400% as determined by UV/Vis while fluorescence revealed 100% of uranyl ion extraction. A closed analysis of the results obtained by using these techniques revealed that the stoichiometry of the main extracted species was 1calixarene:2 uranyl ions. The loading capacity of the calixarene ligand towards the uranyl ions was also investigated using both techniques. UV/Vis resulted to be inadequate for quantifying exactly the loading capacity of the calixarene whereas luminescence was excellent indeed, using a 5.91 x 10 -4 M calixarene concentration, its loading capacity was 0.157 M of free uranyl ions from 0.161 M of uranyl ions present in the aqueous-acidic-salty medium. The extracts from the ability and capacity studies were concentrated to dryness, purified and the dried extracts were analyzed by infrared and neutron activation analysis. By these techniques it was demonstrated that during the extraction of the uranyl ions by the calixarene ligand they form thermodynamically and kinetically stable complexes, since in the solid state, the 1:2, calixarene; uranyl ions stoichiometry was kept with the minimum formula: (UO 2 ) 2 B 8 bL 8 (NO 3 ) 4 (H 2 O) 4 CHCl 3 (CH 3 OH) 3 the methanol molecules come from its purification. It is proposed that B 8 bL 8 calixarene in chloroform medium is a good extractant for the treatment of nuclear wastes or

  13. The Influenced of Salting Out Agent of Phosphat Ion and Ferrosulfamic in Extraction of Thorium and Uranium

    International Nuclear Information System (INIS)

    Busron Masduki; Didiek Herhady, R.

    2002-01-01

    It was carried out thorium-uranium extraction using one stage mixer settler to investigate the influenced of salting out agent of nitric acid and nitric aluminium. The result of this experiment showed the salting out of agent for nitric aluminium of 0.5 M much more significantly increase the distribution coefficient of uranium, but not for the thorium. The distribution coefficient of thorium much more significantly increased after nitric aluminium addition ≥1.0 M. There was not any meaningly differences the waste volume between nitric acid and nitric aluminium in its utilization. Reductor agent of ion Fe 2+ for chromi and decontaminate agent for protactinium in feed extraction, did not any influences of thorium and uranium distribution coefficient. (author)

  14. Upgraded millimeter-wave interferometer for measuring the electron density during the beam extraction in the negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tokuzawa, T., E-mail: tokuzawa@nifs.ac.jp; Kisaki, M.; Nagaoka, K.; Ito, Y.; Ikeda, K.; Nakano, H. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Tsumori, K.; Osakabe, M.; Takeiri, Y. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); The Graduate University for Advanced Studies, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Kaneko, O. [National Institutes of Natural Sciences, 4-3-13 Toranomon, Minato-ku, Tokyo 105-0001 (Japan)

    2016-11-15

    The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 10{sup 15} to 3 × 10{sup 18} m{sup −3} in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

  15. Mechanical design and fabrication of the transverse field focusing (TFF) matching/pumping section for negative ion based neutral beam systems

    International Nuclear Information System (INIS)

    Purgalis, P.; Anderson, O.A.; Koehler, G.W.; Maruyama, Y.; Matuk, C.A.; Owren, H.M.; Paterson, J.A.; Wandesforde, A.H.

    1985-11-01

    A negative ion based neutral beam injection system is under development as proof-of-principle demonstration of a radiation-hardened beamline. The beamline consists of a source, a pre-accelerator, a matching/pumping (M/P) section, and an accelerator. The function of the M/P section is to provide vacuum pumping, to remove electrons, to provide beam edge confinement, to compress the beam thickness to match the requirements of the accelerator, and to transport the 1A, 80 keV, 25 cm high H - ribbon beam to the accelerator entrance. Details of the design and fabrication of the M/P section are presented. The M/P section has eight separate, high voltage electrodes forming an ''S'' shaped beam path. Electrons are removed by the electron trap in this path. Beam edge confinement and thickness compression is accomplished by the curvature and face contour of the electrodes. Design heat loads are described. Electrode fabrication is discussed, and the cryopumps used are described

  16. Measurements of activation reaction rates in transverse shielding concrete exposed to the secondary particle field produced by intermediate energy heavy ions on an iron target

    International Nuclear Information System (INIS)

    Ogawa, T.; Morev, M.N.; Iimoto, T.; Kosako, T.

    2012-01-01

    Reaction rate distributions were measured inside a 60-cm thick concrete pile placed at the lateral position of a thick (stopping length) iron target that was bombarded with heavy ions, 400 MeV/u C and 800 MeV/u Si. Foils of aluminum and gold, as well as gold, tungsten and manganese covered with cadmium were inserted at various locations in the concrete pile to serve as activation detectors. Features of reaction rate distribution, such as the shape of the reaction rate profile, contribution of the neutrons from intra-nuclear cascade and that from evaporation to the activation reactions are determined by the analysis of measured reaction rates. The measured reaction rates were compared with those calculated with radiation transport simulation codes, FLUKA and PHITS, to verify their capability to predict induced activity. The simulated reaction rates agree with the experimental results within a factor of three in general. However, systematic discrepancies between simulated reaction rates and measured reaction rates attributed to the neutron source terms are observed.

  17. COMMISSIONING RESULTS OF SLOW EXTRACTION OF HEAVY IONS from THE AGS BOOSTER

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; BELLAVIA, S.; BINELLO, S.; BRELSFORD, B.; DUMONT, D.; ENG, W.; GARDNER, C.; GASSNER, D.; GLENN, J.W.; HAMMONS, L.; HOCK, J.; HOFF, L.; HUTCHINSON, E.; JAMILKOWSKI, J.; KLING, N.; KOTLYAR, Y.; KRISHOCK, A.; LOCKEY, R.; MAPES, M.; MARNERIS, I.; MARR, G.; MCNERNEY, A.; MEYER, A.; MORRIS, J.; NAYLOR, C.; NEMESURE, S.; PHILLIPS, D.; RUSEK, A.; RYAN, J.; SHREY, T.; SNYDSTRUP, L.; TSOUPAS, N.; VANKUIK, B.; ZAHARIOU-COHEN, K.; ZENO, K.

    2003-01-01

    Brookhaven's AGS Booster has been modified to deliver slow extracted beam to a new beam line, the NASA Space Radiation Laboratory (NSRL). This facility was constructed in collaboration with NASA for the purpose of performing radiation effect studies for the NASA space program. The design of the resonant extraction system has been described in [1]. A more detailed description, which includes predictions of the slow extracted beam time structure has been described in [2]. In this report we will present results of the system commissioning and performance

  18. EXTRACT

    DEFF Research Database (Denmark)

    Pafilis, Evangelos; Buttigieg, Pier Luigi; Ferrell, Barbra

    2016-01-01

    The microbial and molecular ecology research communities have made substantial progress on developing standards for annotating samples with environment metadata. However, sample manual annotation is a highly labor intensive process and requires familiarity with the terminologies used. We have the...... and text-mining-assisted curation revealed that EXTRACT speeds up annotation by 15-25% and helps curators to detect terms that would otherwise have been missed.Database URL: https://extract.hcmr.gr/......., organism, tissue and disease terms. The evaluators in the BioCreative V Interactive Annotation Task found the system to be intuitive, useful, well documented and sufficiently accurate to be helpful in spotting relevant text passages and extracting organism and environment terms. Comparison of fully manual...

  19. Ion-pair cloud-point extraction: a new method for the determination of water-soluble vitamins in plasma and urine.

    Science.gov (United States)

    Heydari, Rouhollah; Elyasi, Najmeh S

    2014-10-01

    A novel, simple, and effective ion-pair cloud-point extraction coupled with a gradient high-performance liquid chromatography method was developed for determination of thiamine (vitamin B1 ), niacinamide (vitamin B3 ), pyridoxine (vitamin B6 ), and riboflavin (vitamin B2 ) in plasma and urine samples. The extraction and separation of vitamins were achieved based on an ion-pair formation approach between these ionizable analytes and 1-heptanesulfonic acid sodium salt as an ion-pairing agent. Influential variables on the ion-pair cloud-point extraction efficiency, such as the ion-pairing agent concentration, ionic strength, pH, volume of Triton X-100, extraction temperature, and incubation time have been fully evaluated and optimized. Water-soluble vitamins were successfully extracted by 1-heptanesulfonic acid sodium salt (0.2% w/v) as ion-pairing agent with Triton X-100 (4% w/v) as surfactant phase at 50°C for 10 min. The calibration curves showed good linearity (r(2) > 0.9916) and precision in the concentration ranges of 1-50 μg/mL for thiamine and niacinamide, 5-100 μg/mL for pyridoxine, and 0.5-20 μg/mL for riboflavin. The recoveries were in the range of 78.0-88.0% with relative standard deviations ranging from 6.2 to 8.2%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. TRANSVERSELY POLARIZED Λ PRODUCTION

    International Nuclear Information System (INIS)

    BORER, D.

    2000-01-01

    Transversely polarized Λ production in hard scattering processes is discussed in terms of a leading twist T-odd fragmentation function which describes the fragmentation of an unpolarized quark into a transversely polarized Λ. We focus on the properties of this function and its relevance for the RHIC and HERMES experiments

  1. Transversely Compressed Bonded Joints

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Schmidt, Jacob Wittrup; Stang, Henrik

    2012-01-01

    The load capacity of bonded joints can be increased if transverse pressure is applied at the interface. The transverse pressure is assumed to introduce a Coulomb-friction contribution to the cohesive law for the interface. Response and load capacity for a bonded single-lap joint was derived using...

  2. Transverse Localization of Light

    NARCIS (Netherlands)

    Raedt, Hans De; Lagendijk, Ad; Vries, Pedro de

    1989-01-01

    We study the propagation of light through a semi-infinite medium with transverse disorder (that is, disorder in two directions only). We show that such a system exhibits strong two-dimensional localization by demonstrating that on propagation a beam expands until the transverse localization length

  3. Synergistic extraction of Eu(III) with N-phosphorylated bis-ureas and chlorinated cobalt bis(dicarbollide) ion

    Energy Technology Data Exchange (ETDEWEB)

    Selucky, P.; Bubenikova, M.; Rais, J. [UJV Rez, a.s., Rez near Prague (Czech Republic); Gruener, B. [Academy of Sciences of the Czech Republic, Rez near Prague (Czech Republic). Inst. of Inorganic Chemistry; Brusko, V.V. [JSC NIIneftepromchim, Kazan (Russian Federation)

    2013-03-01

    Extraction of Eu(III) with a synergistic mixture of polydentate N-phosphorylated bis-ureas with the general formula (i-PrO){sub 2}P(O)NHC(O)NHXNHC(O)NHP(O)(Oi-Pr){sub 2} (X = (CH{sub 2}){sub 7}, (CH{sub 2}){sub 2}O(CH{sub 2}){sub 2} and (CH{sub 2}){sub 2}O(CH{sub 2}){sub 2}O(CH{sub 2}){sub 2}) and chlorinated cobalt bis(dicarbollide) ion (CCD-) with formula closo-[(1,2-C{sub 2}B{sub 9}H{sub 8}Cl{sub 3}){sub 2}-3-Co]{sup -} was studied using nitrobenzene as the solvent. Extraction of Eu(III) was very effective up to high concentrations of nitric acid. Eu(III) is most likely extracted into the organic phase as the [EuL{sub 2}]{sup 3+} species whereas the positive charge of extracted complex is compensated by CCD and/or nitrate anions. (orig.)

  4. New ion selective materials. Application to the selective extraction of caesium

    International Nuclear Information System (INIS)

    Favre-Reguillon, Alain

    1996-01-01

    This research thesis addresses the synthesis and assessment of ion selective materials. The first part reports the development of a general method of assessment of ion selective materials. In the second part, the author describes different methods used to insolubilize macro-cycles on hydrophilic polymers. The obtained polyurethanes are synthesised. These hydrophilic polymers display interesting complexing properties and selectivities with respect to cations of alkali metals. Then the author addresses the improvement of selectivity with respect to caesium of ion exchange resorcinol-formaldehyde resins. Different factors affecting selectivity are identified, and the concept of molecular print is used to study the improvement of selectivity. The effect of macro-cyclic structures on phenolic resins with respect to caesium is highlighted [fr

  5. Extracting integrated and differential cross sections in low energy heavy-ion reactions from backscattering measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sargsyan, V. V. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Yerevan State University, 0025 Yerevan (Armenia); Adamian, G. G., E-mail: adamian@theor.jinr.ru [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Antonenko, N. V. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Mathematical Physics Department, Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); Diaz-Torres, A. [European Centre for Theoretical Studies in Nuclear Physics and Related Areas, I-38123 Villazzano, Trento (Italy); Gomes, P. R. S. [de Fisica, Universidade Federal Fluminense, Av. Litorânea, s/n, Niterói, R.J. 24210-340 (Brazil); Lenske, H. [Institut für Theoretische Physik der Justus–Liebig–Universität, D–35392 Giessen (Germany)

    2016-07-07

    We suggest new methods to extract elastic (quasi-elastic) scattering angular distribution and reaction (capture) cross sections from the experimental elastic (quasi-elastic) backscattering excitation function taken at a single angle.

  6. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  7. Analytical and numerical studies of positive ion beam expansion for surface treatment applications

    Science.gov (United States)

    Lounes-Mahloul, Soumya; Bendib, Abderrezeg; Oudini, Noureddine

    2018-01-01

    The aim of this work is to study the expansion in vacuum, of a positive ion beam with the use of one dimensional (1D) analytic model and a two dimensional Particle-In-Cell (2D-PIC) simulation. The ion beam is extracted and accelerated from preformed plasma by an extraction system composed of two polarized parallel perforated grids. The results obtained with both approaches reveal the presence of a potential barrier downstream the extraction system which tends to reflect the ion flux. The dependence of the critical distance for which all extracted ions are reflected, is investigated as a function of the extracted ion beam current density. In particular, it is shown that the 1D model recovers the well-known Child-Langmuir law and that the 2D simulation presents a significant discrepancy with respect to the 1D prediction. Indeed, for a given value of current density, the transverse effects lead to a greater critical distance.

  8. A study on prevention of an electric discharge at an extraction electrode of an electron cyclotron resonance ion source for cancer therapy.

    Science.gov (United States)

    Kishii, Y; Kawasaki, S; Kitagawa, A; Muramatsu, M; Uchida, T

    2014-02-01

    A compact ECR ion source has utilized for carbon radiotherapy. In order to increase beam intensity with higher electric field at the extraction electrode and be better ion supply stability for long periods, electric geometry and surface conditions of an extraction electrode have been studied. Focusing attention on black deposited substances on the extraction electrode, which were observed around the extraction electrode after long-term use, the relation between black deposited substances and the electrical insulation property is investigated. The black deposited substances were inspected for the thickness of deposit, surface roughness, structural arrangement examined using Raman spectroscopy, and characteristics of electric discharge in a test bench, which was set up to simulate the ECR ion source.

  9. Complementary experimental-simulational study of surfactant micellar phase in the extraction process of metallic ions: Effects of temperature and salt concentration

    Science.gov (United States)

    Soto-Ángeles, Alan Gustavo; Rodríguez-Hidalgo, María del Rosario; Soto-Figueroa, César; Vicente, Luis

    2018-02-01

    The thermoresponsive micellar phase behaviour that exhibits the Triton-X-100 micelles by temperature effect and addition of salt in the extraction process of metallic ions was explored from mesoscopic and experimental points. In the theoretical study, we analyse the formation of Triton-X-100 micelles, load and stabilization of dithizone molecules and metallic ions extraction inside the micellar core at room temperature; finally, a thermal analysis is presented. In the experimental study, the spectrophotometric outcomes confirm the solubility of the copper-dithizone complex in the micellar core, as well as the extraction of metallic ions of aqueous environment via a cloud-point at 332.2 K. The micellar solutions with salt present a low absorbance value compared with the micellar solutions without salt. The decrease in the absorbance value is attributed to a change in the size of hydrophobic region of colloidal micelles. All transitory stages of extraction process are discussed and analysed in this document.

  10. Determination of extractable fluoride in contaminated soils with ion-selective electrode

    OpenAIRE

    Mirlean, Nicolai; Baraj, Besnik; Garcia, Marina Reback Domingues; Niencheski, Luis Felipe Hax; Baisch, Paulo Roberto Martins; Casartelli, Maria Regina de Oliveira; Robinson, Daniel

    2003-01-01

    In a factorial design study involving the determination of F- by ion-selective electrodes, a significant interference was demonstrated for Fe, with an even more pronounced interference for Al. The fluoride leaching procedure from polluted soil showed more reliable results using 0.5 M citric acid

  11. Influence of zirconium ion concentration in model extraction systems TBP - diluents - Zr+4 - nitric acid

    International Nuclear Information System (INIS)

    Rogoz, F.; Tlalka, M.

    1987-07-01

    In systems containing TBP, MBP, DBP and 1-butanol stable emulsions and precipitates are formed which separation is difficult in certain domain of concentration in zirconium ions. MPB and DBP increase stability of primary emulsion in kerosen and carbon tetrachloride but for different concentrations of nitric acid. Addition of 1-butanol decreases slightly the stability of primary emulsion [fr

  12. A polyaniline-magnetite nanocomposite as an anion exchange sorbent for solid-phase extraction of chromium(VI) ions

    International Nuclear Information System (INIS)

    Rezvani, Mehdi; Asgharinezhad, Ali Akbar; Ebrahimzadeh, Homeira; Shekari, Nafiseh

    2014-01-01

    This work describes a novel polyaniline-magnetite nanocomposite and its application to the preconcentration of Cr(VI) anions. The material was obtained by oxidative polymerization of aniline in the presence of magnetite nanoparticles. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Extraction time, amount of magnetic sorbent and pH value were selected as the main factors affecting sorption. The sorption capacity of the sorbent for Cr(VI) is 54 mg g −1 . The type, volume and concentration of the eluents, and the elution time were selected as main factors in the optimization study of the elution step. Following sorption and elution, the Cr(VI) ions were reacted with diphenylcarbazide, and the resulting dye was quantified by HPLC with optical detection at 546 nm. The limit of detection is 0.1 μg L −1 , and all the relative standard deviations are <6.3 %. The nanocomposite was successfully applied to the rapid extraction and determination of trace quantities of Cr(VI) ions in spiked water samples. (author)

  13. Selective solid-phase extraction of Ni(II) by an ion-imprinted polymer from water samples

    International Nuclear Information System (INIS)

    Saraji, Mohammad; Yousefi, Hamideh

    2009-01-01

    A new ion-imprinted polymer (IIP) material was synthesized by copolymerization of 4-vinylpyridine as monomer, ethyleneglycoldimethacrylate as crosslinking agent and 2,2'-azobis-sobutyronitrile as initiator in the presence of Ni-dithizone complex. The IIP was used as sorbent in a solid-phase extraction column. The effects of sampling volume, elution conditions, sample pH and sample flow rate on the extraction of Ni ions form water samples were studied. The maximum adsorption capacity and the relative selectivity coefficients of imprinted polymer for Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were calculated. Compared with non-imprinted polymer particles, the IIP had higher selectivity for Ni(II). The relative selectivity factor (α r ) values of Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were 21.6, 54.3, and 22.7, respectively, which are greater than 1. The relative standard deviation of the five replicate determinations of Ni(II) was 3.4%. The detection limit for 150 mL of sample was 1.6 μg L -1 using flame atomic absorption spectrometry. The developed method was successfully applied to the determination of trace nickel in water samples with satisfactory results.

  14. Selective solid-phase extraction using oxidized activated carbon modified with triethylenetetramine for preconcentration of metal ions

    Science.gov (United States)

    Zhang, Li; Chang, Xijun; Li, Zhenhua; He, Qun

    2010-02-01

    A new selective solid-phase extractant using activated carbon as matrix which was purified, oxidized and modified by triethylenetetramine (AC-TETA) was prepared and characterized by FT-IR spectroscopy. At pH 4, quantitative extraction of trace Cr(III), Fe(III) and Pb(II) was obtained and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 0.5 mol L -1 HCl. The maximum static adsorption capacity of sorbent for Cr(III), Fe(III) and Pb(II) was 34.6, 36.5 and 51.9 mg g -1, respectively. The time of quantitative adsorption was less than 2 min. The detection limits of the method was found to be 0.71, 0.35 and 0.45 ng mL -1 for Cr(III), Fe(III) and Pb(II), and the relative standard deviation (RSD) was 3.7%, 2.2% and 2.5%, respectively. Moreover, the method was free from interference with common coexiting ions. The method was also successfully applied to the preconcentration of trace Cr(III), Fe(III) and Pb(II) in synthetic samples and a real sample with satisfactory results.

  15. Extracting ion emission lines from femtosecond-laser plasma x-ray spectra heavily contaminated by spikes

    International Nuclear Information System (INIS)

    Gasilov, S. V.; Faenov, A. Ya.; Pikuz, T. A.; Villoresi, P.; Poletto, L.; Stagira, S.; Calegari, F.; Vozzi, C.; Nisoli, M.

    2007-01-01

    Nowadays charged-coupled device (CCD) detectors are widely used for the registration of multicharged ions x-ray spectra. These spectra are generated in a plasma during interaction of ultrashort, ultraintense laser pulses with solid targets. Strong parasitic radiation from the plasma affects CCD detectors and contaminates resulting spectra, so that spectral features can be completely covered by noise even during measurements with a very short accumulation time. In this work we propose a ''mean to median'' (M2M) algorithm for noise suppression in femtosecond laser plasma x-ray spectra. Series of spectra is necessary for the identification of corrupted data points by the developed method. The algorithm was tested with model spectra which reflect main features of experimental data. In practice we used it for extracting information about spectral lines of Ne-like Fe ions and He-like Al ions which allowed us to calculate plasma parameters. It is demonstrated that M2M method is able to clean spectra with more than 10% of corrupted pixels. Fluctuations in intensity of spectral lines induced by laser instability do not affect validity of the proposed method

  16. On the extraction of ion association data and transference numbers from ionic diffusivity and conductivity data in polymer electrolytes

    International Nuclear Information System (INIS)

    Stolwijk, Nicolaas A.; Kösters, Johannes; Wiencierz, Manfred; Schönhoff, Monika

    2013-01-01

    The degree of ion association in polymer electrolytes is often characterized by the Nernst–Einstein deviation parameter Δ, which quantifies the relative difference between the true ionic conductivity directly measured by electrical methods and the hypothetical maximum conductivity calculated from the individual ionic self-diffusion coefficients. Despite its unambiguous definition, the parameter Δ is a global quantity with limited explanatory power. Similar is true for the cation transport number t cat * , which relies on the same ionic diffusion coefficients usually measured by nuclear magnetic resonance or radiotracer methods. Particularly in cases when neutral ion pairs dominate over higher-order aggregates, more specific information can be extracted from the same body of experimental data that is used for the calculation of Δ and t cat * . This information concerns the pair contributions to the diffusion coefficient of cations and anions. Also the true cation transference number based on charged species only can be deduced. We present the basic theoretical framework and some pertinent examples dealing with ion pairing in polymer electrolytes

  17. Fluorometric determination of aluminium (III) and cadmium (II) by solvent extraction of the ternary complex composed of metal ion, 8-hydroxy-5-quinolinesulfonic acid, and methyltrioctylammonium ion

    International Nuclear Information System (INIS)

    Kondoh, Yukihiro; Kataoka, Masamitsu; Kambara, Tomihito

    1982-01-01

    A fluorometric micro determination of aluminium (III) and cadmium (II) using the formation of metal-8-hydroxy-5-quinolinesulfonic acid-capriquat (methyltrioctylammonium) ternary complex is described. These complexes are easily extracted into chloroform phase and the extract emits a strong fluorescence. Spectra of aluminium (III) and cadmium (II) ternary complexes have the excitation maximum at 396 nm and 400 nm, and emission maximum at 501 nm and 524 nm, respectively. Fluorescence intensity of the aluminium (III) and cadmium (II) ternary complexes extracted into chloroform showed the constant and maximum values in the pH range of aqueous phase from 5.3 to 8.5 and 8.1 to 8.5, respectively. The calibration curves for aluminium (III) and cadmium (II) show good proportionality int the concentration range from 0.5 to 5.0 and 1.0 to 50.0 μg, respectively. The relative standard deviation observed with four measurements was found to be 1.8% for 0.5 μg of aluminium (III) and 1.1% for 10.0 μg of cadmium (II). The effect of diverse ions is studied and a 25-fold amount of Cu(II), Ni(II), Fe(II), Fe(III) in weight gave errors, however, the interferences were easily eliminated by the addition of appropriate masking agent. In the determination of cadmium (II), an equal amount of Co(II), Ni(II), Mn(II), Fe(III) and twice amount of Al(III) gave negative errors, however, the interference of Fe(III) and Al(III) were also eliminated as above. (author)

  18. Investigation into chemism of multivalent element ions reactions with organic reagents. XXXII. Extractable indium complex with alizarin-3-sulfonic acid and diphenylguanidine

    Energy Technology Data Exchange (ETDEWEB)

    Biryuk, E A; Nazarenko, V A [AN Ukrainskoj SSR, Kiev. Inst. Obshchej i Neorganicheskoj Khimii; AN Ukrainskoj SSR, Odessa. Inst. Obshchej i Neorganicheskoj Khimii)

    1975-09-01

    Spectrophotometric investigations have been made in to the interaction of indium with alizarin red S (alizarin-3-sulphonic acid) when extracting it with chloroform. The complex is extracted as an ion association with diphenylguanidine, in which the ratio In:Aliz:DPG = 1:3:3. The central ion In/sup 3 +/ substitutes three protons in three particles of the ligand. The structure of the complex being extracted is discussed. Molar absorbancy index of the complex in the chloroform extract (2.8x10/sup 4/) is twice as great as in the aqueous solution. The effect of the pH value on the formation of the indium complexes extracted is studied.

  19. In Vitro Ion Chelating, Antioxidative Mechanism of Extracts from Fruits and Barks of Tetrapleura tetraptera and Their Protective Effects against Fenton Mediated Toxicity of Metal Ions on Liver Homogenates

    Directory of Open Access Journals (Sweden)

    Bruno Moukette Moukette

    2015-01-01

    Full Text Available The aim of the present study was to investigate the antioxidant activity and protective potential of T. tetraptera extracts against ion toxicity. The antioxidant activity of the extracts was investigated spectrophotometrically against several radicals (1,1-diphenyl-2-picrylhydrazyl (DPPH•, 2,2′-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid (ABTS•, hydroxyl radical (HO•, and nitric oxide (NO•, followed by the ferric reducing power, total phenols, flavonoid, and flavonol contents. The effects of the extracts on catalase (CAT, superoxide dismutase (SOD, and peroxidase activities were also determined using the standard methods as well as the polyphenol profile using HPLC. The results showed that the hydroethanolic extract of T. tetraptera (CFH has the lowest IC50 value with the DPPH, ABTS, OH, and NO radicals. The same extract also exhibited the significantly higher level of total phenols (37.24 ± 2.00 CAE/g dried extract; flavonoids (11.36 ± 1.88 QE/g dried extract; and flavonols contents (3.95 ± 0.39 QE/g dried extract. The HPLC profile of T. tetraptera revealed that eugenol (958.81 ± 00 mg/g DW, quercetin (353.78 ± 00 mg/g DW, and rutin (210.54 ± 00 mg/g DW were higher in the fruit than the bark extracts. In conclusion, extracts from T. tetraptera may act as a protector against oxidative mediated ion toxicity.

  20. Characteristics of a large vacuum wave precursor on the SABRE voltage adder MITL and extraction ion diode

    International Nuclear Information System (INIS)

    Cuneo, M.E.; Hanson, D.L.; Menge, P.R.; Poukey, J.W.; Savage, M.E.

    1994-01-01

    SABRE (Sandia Accelerator and Beam Research Experiment) is a ten-cavity linear induction magnetically insulated voltage adder (6 MV, 300 kA) operated in positive polarity to investigate issues relevant to ion beam production and propagation for inertial confinement fusion. The voltage adder section is coupled to an applied-B extraction ion diode via a long coaxial output transmission line. Observations indicate that the power propagates in a vacuum wave prior to electron emission. After the electron emission threshold is reached, power propagates in a magnetically insulated wave. The precursor is observed to have a dominant impact on he turn-on, impedance history, and beam characteristics of applied-B ion diodes since the precursor voltage is large enough to cause electron emission at the diode from both the cathode feed and cathode tips. The amplitude of the precursor at the load (3--4.5 MV) is a significant fraction of the maximum load voltage (5--6 MV) because (1) the transmission line gaps ( ∼ 9 cm at output) and therefore impedances are relatively large, and hence the electric field threshold for electron emission (200 to 300 kV/cm) is not reached until well into the power pulse rise time; and (2) the rapidly falling forward wave and diode impedance reduces the ratio of main pulse voltage to precursor voltage. Experimental voltage and current data from the transmission line and the ion diode will be presented and compared with TWOQUICK (2-D electromagnetic PIC code) simulations and analytic models

  1. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions

    Energy Technology Data Exchange (ETDEWEB)

    Tu Zhifeng; He Qun [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Chang, Xijun, E-mail: tuzhf07@lzu.cn [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Hu Zheng; Gao Ru; Zhang Lina; Li Zhenhua [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China)

    2009-09-07

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L{sup -1} HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g{sup -1} for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL{sup -1} for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  2. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions.

    Science.gov (United States)

    Tu, Zhifeng; He, Qun; Chang, Xijun; Hu, Zheng; Gao, Ru; Zhang, Lina; Li, Zhenhua

    2009-09-07

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n=8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  3. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions

    International Nuclear Information System (INIS)

    Tu Zhifeng; He Qun; Chang, Xijun; Hu Zheng; Gao Ru; Zhang Lina; Li Zhenhua

    2009-01-01

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L -1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g -1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL -1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  4. Determination of the working conditions of the system for ion extraction from glow discharge plasma

    International Nuclear Information System (INIS)

    Murlak-Stachura, H.; Pilat, M.

    1988-01-01

    The discharge plasma was formed in discharge tube 110 cm long and 5.5 cm in diameter. An extraction probe with a bore 0.2 mm in diameter was on the tube wall about 40 cm from the anode. The probe characteristic was measured at determined pressure and intensity of discharge current. 8 refs., 3 figs. (A.S.)

  5. Acid Extraction - Ion Exchange Recovery of Cinchona Alkaloids Process and Plant Development

    Science.gov (United States)

    1945-06-08

    center of the tank and dispersed by the rising jet from the bottom. From the operation of the scale model it was ascertained that the rate of...were then extracted from the precipitate by means of an alkali and an organic solvent« (18) Fink has suggested the use of a mixture of kaolin and

  6. Time‐of‐flight secondary ion mass spectrometry imaging of biological samples with delayed extraction for high mass and high spatial resolutions

    Science.gov (United States)

    Vanbellingen, Quentin P.; Elie, Nicolas; Eller, Michael J.; Della‐Negra, Serge; Touboul, David

    2015-01-01

    Rationale In Time‐of‐Flight Secondary Ion Mass Spectrometry (TOF‐SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF‐SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a mass resolution of several thousand or a sub‐µm lateral resolution, but the combination of both is generally not possible. Methods With a TOF‐SIMS setup, a delayed extraction applied to secondary ions has been studied extensively on rat cerebellum sections in order to compensate for the effect of long primary ion bunches. Results The use of a delayed extraction has been proven to be an efficient solution leading to unique features, i.e. a mass resolution up to 10000 at m/z 385.4 combined with a lateral resolution of about 400 nm. Simulations of ion trajectories confirm the experimental determination of optimal delayed extraction and allow understanding of the behavior of ions as a function of their mass‐to‐charge ratio. Conclusions Although the use of a delayed extraction has been well known for many years and is very popular in MALDI, it is much less used in TOF‐SIMS. Its full characterization now enables secondary ion images to be recorded in a single run with a submicron spatial resolution and with a mass resolution of several thousand. This improvement is very useful when analyzing lipids on tissue sections, or rare, precious, or very small size samples. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. PMID:26395603

  7. Computer experiments on ion beam cooling and guiding in fair-wind gas cell and extraction RF-funnel system

    International Nuclear Information System (INIS)

    Varentsov, Victor; Wada, Michiharu

    2004-01-01

    Here we present results of the further development of two novel ideas in the field of slow RI-beams production. They are a fair-wind gas cell concept for big-size high-pressure buffer gas cells and a new approach to the extraction system. For this purpose, detailed gas dynamic simulations based on the solution of a full system of time-dependent Navier-Stokes equations have been performed for both the fair-wind gas cell of 500 mm length at 1 bar helium buffer gas pressure and the RF-funnel extraction system at low buffer gas pressure. The results of gas dynamic calculations were used for detailed microscopic Monte Carlo ion-beam trajectory simulations under the combined effect of the buffer gas flow and electric fields of the RF-funnels. The obtained results made it apparent that the use of the fair-wind gas cell concept and extraction RF-funnels look very promising for production of high-quality low-energy RI-beams

  8. Radioanalytical determination of plutonium and americium using ion exchange and extraction chromatography technique in urine

    International Nuclear Information System (INIS)

    Santhanakrishnan, V.; Sreedevi, K.R.; Rajaram, S.; Ravi, P.M.

    2011-01-01

    The use of anion exchange chromatography for the separation of Pu and extraction chromatography technique for the separation of Am from urine samples was studied. In the earlier method, Pu separation was carried out by anion exchange chromatography followed by Am separation by cation exchange chromatography. The chemical recovery of Am obtained by cation exchange separation method was inconsistent and low in the range 30-70%. In this study, the average Pu recovery obtained using anion exchange chromatography was 89.2 with standard deviation of 10.4 and the average Am recovery obtained using extraction chromatography with TRU resin was 77.4 with standard deviation of 14.8. Moreover, Am separation could be completed within three hours using the TRU column compared to two days that were required for the cation exchange chromatography. (author)

  9. Alternative extraction of alkaloid anticarcinogens from Brazilian "vinca rosea" using Ion exchange chromatography

    Directory of Open Access Journals (Sweden)

    Sérgio Freire de Carvalhaes

    Full Text Available Extracts in ethanol and ethanol-ammonia of dried leaves from Catharanthus roseus, gathered at Rio de Janeiro state, were adsorbed in a strongly acidic cation exchange resin with sulfonic acid group, using the finite bath method, resulting in an alkaloid retained fraction and an acidic and neutral unretained fraction. High Performance Liquid Chromatography showed the isolation of the alkaloid fraction to be highly selective and with good performance, with an absence of alkaloids in the unretained fraction, while the retained fraction presented 1,54-6,35 mg/g of vindoline and 0,12-0,91 mg/g of vinblastine, common for an alkaloid-rich concentrate, usually obtained by classic extraction with several steps using solvents.

  10. Recording ion channels across soy-extracted lecithin bilayer generated by water-soluble quantum dots

    Science.gov (United States)

    Sarma, Runjun; Mohanta, Dambarudhar

    2014-02-01

    We report on the quantum dot (QD)-induced ion channels across a soya-derived lecithin bilayer supported on a laser drilled of ~100 μm aperture of cellulose acetate substrate that separates two electrolytic chambers. Adequate current bursts were observed when the bilayer was subjected to a gating voltage. The voltage-dependent current fluctuation, across the bilayer, was attributed to the insertion of ~20 nm sized water-soluble CdSe QDs, forming nanopores due to their spontaneous aggregation. Apart from a closed state, the first observable conductance levels were found as 6.3 and 11 nS, as for the respective biasing voltages of -10 and -20 mV. The highest observable conductance states, at corresponding voltages were ~14.3 and 21.1 nS. Considering two simplified models, we predict that the non-spherical pores (dnspore) can be a better approximation over spherical nanopores (dspore) for exhibiting a definite conductance level. At times, even dnspore ≤ 4dspore and that the non-spherical nanopores were associated with a smaller No. of QDs than the case for spherical nanopores, for a definite conductance state. It seems like the current events are partly stochastic, possibly due to thermal effects on the aggregated QDs that would form nanopores. The dwell time of the states was predicted in the range of 384-411 μs. The ion channel mechanism in natural phospholipid bilayers over artificial ones will provide a closer account to understand ion transport mechanism in live cells and signaling activity including labelling with fluorescent QDs.

  11. Determination of the extraction efficiency for {sup 233}U source α-recoil ions from the MLL buffer-gas stopping cell

    Energy Technology Data Exchange (ETDEWEB)

    Wense, Lars v.d.; Seiferle, Benedict; Thirolf, Peter G. [Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany); Laatiaoui, Mustapha [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz Institut Mainz, Mainz (Germany)

    2015-03-01

    Following the α decay of {sup 233}U, {sup 229}Th recoil ions are shown to be extracted in a significant amount from the MLL buffer-gas stopping cell. The produced recoil ions and subsequent daughter nuclei are mass purified with the help of a customized quadrupole mass spectrometer. The combined extraction and mass purification efficiency for {sup 229}Th{sup 3+} is determined via MCP-based measurements and via the direct detection of the {sup 229}Th α decay. A large value of (10±2)% for the combined extraction and mass purification efficiency of {sup 229}Th{sup 3+} is obtained at a mass resolution of about 1u/e. In addition to {sup 229}Th, also other α-recoil ions of the {sup 233,} {sup 232}U decay chains are addressed. (orig.)

  12. Neutron-activation determination of phosphorus using extraction separation of phosphate-ion with dialkylti dinitrates

    International Nuclear Information System (INIS)

    Yakovlev, Yu.V.; Kolotov, V.P.

    1981-01-01

    The selectivity of phosphorus (5) separation has been studied using dialkyltin dinitrates-promising reagents for extraction of oxygen-containing anions. Procedures have been developed for separating phosphorus in the presence of macro amounts of some interfering-elements (Al, Fe, Mo and Zr). The procedure was used for neutron activation determination of phosphorus in aluminium. The limit of detection was 5x10 -10 g [ru

  13. Electrochemical monitoring of the co-extraction of water with hydrated ions into an organic solvent

    Czech Academy of Sciences Publication Activity Database

    Mareček, Vladimír

    2018-01-01

    Roč. 88, MAR 2018 (2018), s. 57-60 ISSN 1388-2481 R&D Projects: GA ČR(CZ) GA17-09980S Institutional support: RVO:61388955 Keywords : Liquid/liquid interface * Water co-extraction dynamics * Emulsification Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis) Impact factor: 4.396, year: 2016

  14. A note on extracting electronic stopping from energy spectra of backscattered slow ions applying Bragg's rule

    Science.gov (United States)

    Bruckner, B.; Roth, D.; Goebl, D.; Bauer, P.; Primetzhofer, D.

    2018-05-01

    Electronic stopping measurements in chemically reactive targets, e.g., transition and rare earth metals are challenging. These metals often contain low Z impurities, which contribute to electronic stopping. In this article, we present two ways how one can correct for the presence of impurities in the evaluation of proton and He stopping in Ni for primary energies between 1 and 100 keV, either considering or ignoring the contribution of the low Z impurities to multiple scattering. We find, that for protons either method leads to concordant results, but for heavier projectiles, e.g. He ions, the influence on multiple scattering must not be neglected.

  15. Modified approaches to the complexometric extraction of metal ions into supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Ager, P.; Lopez, C.D.; Marshall, W.D.

    2000-01-01

    A modified nebulizing assembly from a commercial atomic absorption spectrometry (AAS) unit served to interface the eluate from a supercritical carbon, dioxide (Sc-CO 2 ) extractor with a flame atomic absorption spectrometer and provided low to sub-ng limits of detection for several elements that were detected only inefficiently with an all-silica T-tube interface. The unit was used to monitor the progress of complexometric extractions of cobalt and nickel (2.5 or 25 μg/ml) from aqueous medium. Modifications to the general process for metal mobilisation included (i) a back-filling procedure during the initial pressurisation of the extractor and (ii) the separation of the derivatization reaction from the subsequent extraction. When coupled with (iii) the addition of ethyl acetate or methylisobutyl Ketone to the mobile phase, residual levels of analyte Co and Ni were reduced to the limit of detection with a single extraction. A heated column of iron granules Fe o efficiently removed metal 2,4-pentanedionate and diethyldithiocarbamate complexes from the SCF extractor eluate but did not liberate any complexing reagent. A sea sand column, heated to the same temperature, was less efficient at removing metals but did liberate modest amounts of 2,4-pentanedione back into the mobile phase. (author)

  16. Identification of fermentation inhibitors in wood hydrolyzates and removal of inhibitors by ion exchange and liquid-liquid extraction

    Science.gov (United States)

    Luo, Caidian

    1998-12-01

    Common methods employed in the ethanol production from biomass consist of chemical or enzymatic degradation of biomass into sugars and then fermentation of sugars into ethanol or other chemicals. However, some degradation products severely inhibit the fermentation processes and substantially reduce the efficiency of ethanol production. How to remove inhibitors from the reaction product mixture and increase the production efficiency are critical in the commercialization of any processes of energy from biomass. The present study has investigated anion exchange and liquid-liquid extraction as potential methods for inhibitor removal. An analytical method has been developed to identify the fermentation inhibitors in a hydrolyzate. The majority of inhibitors present in hybrid poplar hydrolyzate have positively been identified. Ion exchange with weak basic Dowex-MWA-1 resin has been proved to be an effective mean to remove fermentation inhibitors from hybrid poplar hydrolyzate and significantly increase the fermentation productivity. Extraction with n-butanol might be a preferred way to remove inhibitors from wood hydrolyzates and improve the fermentability of sugars in the hydrolyzates. n-Butanol also removes some glucose, mannose and xylose from the hydrolyzate. Inhibitor identification reveals that lignin and sugar degradation compounds including both aromatic and aliphatic aldehydes and carboxylic acids formed in hydrolysis, plus fatty acids and other components from wood extractives are major fermentation inhibitors in Sacchromyces cerevisiae fermentation. There are 35 components identified as fermentation inhibitors. Among them, 4-hydroxy benzoic acid, 3,4-dihydroxy benzoic acid, syringic acid, syringaldehyde, and ferulic acid are among the most abundant aromatic inhibitors in hybrid poplar hydrolyzate. The conversion of aldehyde groups into carboxylic acid groups in the nitric acid catalyzed hydrolysis reduces the toxicity of the hydrolyzate. A wide spectrum of

  17. BIOSORBENTS – PROSPECTIVE MATERIALS FOR HEAVY METAL IONS EXTRACTION FROM WASTEWATER

    Directory of Open Access Journals (Sweden)

    О. Kovalenko

    2018-04-01

    Full Text Available The article deals with ecological safety, resource saving, economic efficienty in the technologies of wastewater purification from heavy metals ions. It is shown that modern technologies of wastewater purification from such substances need to be improved. А promising way to solve this problem is the production and wide use of carbon sorbents obtained from the waste of processing agricultural raw materials and waste generated at food enterprises. Scientific research is actively carried out in this area. This is due to the possibility of organizing the process of wastewater purification from heavy metal ions in a cheap and effective way. The development of biosorbent production is relevant for Ukraine, as the development of agriculture and food industry is of primary importance. The article presents the results of an analytical review of literary sources on various aspects of the scientific problem. In particular, possible sources of raw materials for the production of biosorbents, classical and modified technologies for their production, mechanisms of biosorption using raw materials with different chemical composition, sorption characteristics of biosorbents, and indicators of the economic efficiency of their production are considered.

  18. Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbakhsh, Sina, E-mail: sinajahanbakhsh@gmail.com; Satir, Mert; Celik, Murat [Department of Mechanical Engineering, Bogazici University, Istanbul 34342 (Turkey)

    2016-02-15

    Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

  19. The difference between the metal ion extracted from the R.F. ion source by applying plasma chemistry reaction and by non-plasma range chemistry reaction

    International Nuclear Information System (INIS)

    Bai Gui Bin

    1987-01-01

    The paper introduced the difference between using plasma chemistry reaction draw metal ion and non-plasma range chemistry reaction in the R.F. ion source. By using of the plasma chemistry reaction draw metal ion higher percentage than non-plasma range chemistry reaction in the R.F. ion source. The authors plasma chemistry reaction to R.F. ion source and implanter successfully. The effect is very well, it has its own characteristic

  20. Liquid-liquid extraction of U(VI), Np(V) et Th(IV) ions by two calix[4]arene carboxyls, and effect of Na+ and K+ alkaline ions

    International Nuclear Information System (INIS)

    Montavon, Gilles

    1996-01-01

    As the process mainly used for the reprocessing of nuclear wastes was the Purex process, this research thesis first presents this process and outlines that it allows the residual fissile matter to be recovered and reused for the fabrication of new fuel elements, but is neither efficient nor safe enough to separate fission and activation products. Thus, this thesis reports the study of extraction and selectivity properties of two compounds derived from the p-tert-butyl-calix[4]arene with respect to actinide ions such as Th(IV), U(VI) and Np(VI). The liquid-liquid extraction technique has been used with chloroform and 1,2-dichloroethane as solvents. After some generalities on actinides, calixarenes and the liquid-liquid extraction technique, and a presentation of the experimental method, the author reports and discusses the extractive properties of the studied calixarenes with respect to Na + and K + ions. Structural studies by proton NMR have been performed. He reports and discusses the liquid-liquid extraction on actinide ions when they are alone or in presence on Na + and K + alkaline ions [fr

  1. Systematic and structural studies of homogeneous and polymeric extractants for the separation and recovery of metal ion: Triennial performance report, August 1, 1983-July 31, 1986

    International Nuclear Information System (INIS)

    Alexandratos, S.D.

    1986-04-01

    Novel polymeric extractants have been synthesized and applied to the recovery of metal ions from dilute aqueous solutions. The new category of dual mechanism bifunctional polymers is introduced as a series of resins which permit highly selective extractions through the use of a reaction additional to ion exchange in the recovery process. The bifunctional phosphinic acid ion exchange/redox resins form the first class of resins within this category. Their synthesis and the recovery of metallic mercury, silver, gold, and copper from their ionic solutions is detailed. Under equilibrium conditions, these resins operate entirely by the redox mechanism until all of the primary phosphinic acid sites are oxidized, followed then by purely ion exchange. Kinetic studies show that the cation's reduction potential determines whether a redox reaction will occur while, at a given reduction potential, the oxidation state determines how rapidly. The significant coordinative ability of the phosphoryl oxygen is also important, though, and is responsible for extracting greater amounts of actinide ions than the sulfonic resins. For those processes where membranes would most appropriately be applied, the modification of polypropylene with interpenetrating polymer network extractants yields a recovery system with almost infinite lifetime. Such networks have been formed from polymers of di(undecenyl) phosphoric acid and found to display significantly enhanced retention within polystyrene bead supports. 10 refs

  2. A new ion imprinted polymer based on Ru(III)-thiobarbituric acid complex for solid phase extraction of ruthenium(III) prior to its determination by ETAAS

    International Nuclear Information System (INIS)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-01-01

    A new ruthenium ion imprinted polymer was prepared from the Ru(III) 2-thiobarbituric acid complex (the template), methacrylic acid or acrylamide (the functional monomers), and ethylene glycol dimethacrylate (the cross-linking agent) using 2,2′-azobisisobutyronitrile as the radical initiator. The ion imprinted polymer was characterized and used as a selective sorbent for the solid phase extraction of Ru(III) ions. The effects of type of functional monomer, sample volume, solution pH and flow rate on the extraction efficiency were studied in the dynamic mode. Ru(III) ion was quantitatively retained on the sorbents in the pH range from 3.5 to 10, and can be eluted with 4 mol L−1 aqueous ammonia. The affinity of Ru(III) for the ion imprinted polymer based on the acrylamide monomer is weaker than that for the polymer based on the methacrylic acid monomer, which therefore was used in interference studies and in analytical applications. Following extraction of Ru(III) ions with the imprint and their subsequent elution from the polymer with aqueous ammonia, Ru(III) was detected by electrothermal atomic absorption spectrometry with a detection limit of 0.21 ng mL −1 . The method was successfully applied to the determination of trace amounts of Ru(III) in water, waste, road dust and platinum ore (CRM SARM 76) with a reproducibility (expressed as RSD) below 6.4 %. (author)

  3. chemical studies on the extraction of certain metal ions from aqueous solution by liquid emulsion membrane

    International Nuclear Information System (INIS)

    Kassem, A.T.

    2011-01-01

    In this thesis four systems are addressed related to the use of liquid emulsion membranes (ELM) based on Co(III)dicarbiolide and. The system was dedicated for permeation of cadmium , cobalt Nickel and lead for use of this system for preconcentration and separation of cadmium, cobalt, nickel and lead. The work carried out in this thesis is presented in three parts, namely; introduction, experimental and results and discussion.The first chapter is the introduction which includes aim of work, basic concepts of liquid membranes; liquid emulsion membranes; different models of emulsion permeation, literature survey of extraction chemistry of cadmium, cobalt, nickel and lead. Chapter two includes the experimental part. In this part detailed outlines on the chemicals and different elements used were given. Different instruments as well as analytical techniques were outlines. The preparation of liquid emulsion membrane and the permeation techniques were presented in details. The third chapter deals with the results and discussion. This chapter is divided into four main parts, the four parts is concerned with cadmium/Co(III) dicarbolide/NTA, EDTA, DPTA and DCTA systems. In this part the permeation of Cd(II) aqueous solution by the membrane used was experimented based on liquid-liquid extraction studies of cadmium from different sodium chloride molarities (from 0.01 to 0.1 M) by 0.01 M Cobalt(III) dicarbolides. It was found that the extraction of with cadmium is higher following in the first system, the permeation of the toxic elements, Cd(II) from HCl/sodium chloride medium was carried out using liquid emulsion membrane containing Co(III)dicarbiolide in xylene as carrier, Spain 80/ Spain 85(1:3) as surfactant and NTA, EDTA, DPTA and DCTA as a stripping solutions.

  4. Chiral dynamics and peripheral transverse densities

    Energy Technology Data Exchange (ETDEWEB)

    Granados, Carlos G. [Uppsala University (Sweden); Weiss, Christian [JLAB, Newport News, VA (United States)

    2014-01-01

    In the partonic (or light-front) description of relativistic systems the electromagnetic form factors are expressed in terms of frame-independent charge and magnetization densities in transverse space. This formulation allows one to identify the chiral components of nucleon structure as the peripheral densities at transverse distances b = O(M{sub {pi}}{sup -1}) and compute them in a parametrically controlled manner. A dispersion relation connects the large-distance behavior of the transverse charge and magnetization densities to the spectral functions of the Dirac and Pauli form factors near the two--pion threshold at timelike t = 4 M{ sub {pi}}{sup 2}, which can be computed in relativistic chiral effective field theory. Using the leading-order approximation we (a) derive the asymptotic behavior (Yukawa tail) of the isovector transverse densities in the "chiral" region b = O(M{sub {pi}}{sup -1}) and the "molecular" region b = O(M{sub N}{sup 2}/M{sub {pi}}{sup 3}); (b) perform the heavy-baryon expansion of the transverse densities; (c) explain the relative magnitude of the peripheral charge and magnetization densities in a simple mechanical picture; (d) include Delta isobar intermediate states and study the peripheral transverse densities in the large-N{ sub c} limit of QCD; (e) quantify the region of transverse distances where the chiral components of the densities are numerically dominant; (f) calculate the chiral divergences of the b{sup 2}-weighted moments of the isovector transverse densities (charge and anomalous magnetic radii) in the limit M{sub {pi}} -> 0 and determine their spatial support. Our approach provides a concise formulation of the spatial structure of the nucleon's chiral component and offers new insights into basic properties of the chiral expansion. It relates the information extracted from low-t elastic form factors to the generalized parton distributions probed in peripheral high-energy scattering processes.

  5. Adsorption of saponin compound in Carica papaya leaves extract using weakly basic ion exchanger resin

    Science.gov (United States)

    Abidin, Noraziani Zainal; Janam, Anathasia; Zubairi, Saiful Irwan

    2016-11-01

    Adsorption of saponin compound in papaya leaves juice extract using Amberlite® IRA-67 resin was not reported in previous studies. In this research, Amberlite® IRA-67 was used to determine the amount of saponin that can be adsorbed using different weights of dry resin (0.1 g and 0.5 g). Peleg model was used to determine the maximum yield of saponin (43.67 mg) and the exhaustive time (5.7 days) prior to a preliminary resin-saponin adsorption study. After adsorption process, there was no significant difference (p>0.05) in total saponin content (mg) for sample treated with 0.1 g (3.79 ± 0.55 mg) and sample treated with 0.5 g (3.43 ± 0.51 mg) dry weight resin. Long-term kinetic adsorption of resin-saponin method (>24 hours) should be conducted to obtain optimum freed saponin extract. Besides that, sample treated with 0.1 g dry weight resin had high free radical scavenging value of 50.33 ± 2.74% compared to sample treated with 0.5 g dry weight resin that had low free radical scavenging value of 24.54 ± 1.66% dry weights. Total saponin content (mg), total phenolic content (mg GAE) and free radical scavenging activity (%) was investigated to determine the interaction of those compounds with Amberlite® IRA-67. The RP-HPLC analysis using ursolic acid as standard at 203 nm showed no peak even though ursolic acid was one of the saponin components that was ubiquitous in plant kingdom. The absence of peak was due to weak solubility of ursolic acid in water and since it was only soluble in solvent with moderate polarity. The Pearson's correlation coefficient for total saponin content (mg) versus total phenolic content (mg GAE) and radical scavenging activity (%) were +0.959 and +0.807. Positive values showed that whenever there was an increase in saponin content (mg), the phenolic content (mg GAE) and radical scavenging activity (%) would also increase. However, as the resin-saponin adsorption was carried out, there was a significant decrease of radical scavenging activity

  6. Design, manufacture and factory testing of the Ion Source and Extraction Power Supplies for the SPIDER experiment

    International Nuclear Information System (INIS)

    Bigi, Marco; Rinaldi, Luigi; Simon, Muriel; Sita, Luca; Taddia, Giuseppe; Carrozza, Saverino; Decamps, Hans; Luchetta, Adriano; Meddour, Abdelraouf; Moressa, Modesto; Morri, Cristiano; Musile Tanzi, Antonio; Recchia, Mauro; Wagner, Uwe; Zamengo, Andrea; Toigo, Vanni

    2015-01-01

    Highlights: • 5 MVA ion source power supplies effectively integrated in 150 m"2 Faraday cage. • Load protection and performance requirements met of custom design high voltage power supplies. • 200 kW tetrode oscillator with 200 kHz frequency range successfully tested. - Abstract: The SPIDER experiment, currently under construction at the Neutral Beam Test Facility in Padua, Italy, is a full-size prototype of the ion source for the ITER Neutral Beam Injectors. The Ion Source and Extraction Power Supplies (ISEPS) for SPIDER are supplied by OCEM Energy Technology s.r.l. (OCEM) under a procurement contract with Fusion for Energy (F4E) covering also the units required for MITICA and ITER injectors. The detailed design of SPIDER ISEPS was finalized in 2011 and manufacture of most components completed by end 2013. The Factory Acceptance Tests took place early 2014. ISEPS, with an overall power rating of 5 MVA, form a heterogeneous set of items including solid state power converters and 1 MHz radiofrequency generators of 200 kW output power. The paper presents the main features of the detailed design developed by OCEM, focusing in particular on the high output voltage pulse step modulators, the high output current resonant converters, the radiofrequency generators by HIMMELWERK GmbH and the architecture and implementation of the complex control system. Details are given on non-standard factory tests verifying the insulation requirements specific to this application. Performance of ISEPS during the factory acceptance tests is described, with emphasis on demonstration of the load protection requirements, a crucial point for all neutral beam power supplies. Finally, key dates of SPIDER ISEPS installation and site testing schedule are provided.

  7. Ion-Pair Extractive Spectrophotometric Assay of Terbinafine Hydrochloride in Pharmaceuticals and Spiked Urine Using Bromocresol Purple

    Science.gov (United States)

    Salem Qarah, N. A.; Basavaiah, K.; Swamy, N.

    2016-09-01

    Two simple, rapid, selective, and sensitive methods were developed and validated for the determination of terbinafi ne hydrochloride (TBH) in pharmaceuticals and urine. The fi rst method (method A) is based on the formation of a yellow ion-pair complex of TBH and bromocresol purple (BCP), a sulfonephthalein dye, in Walpole buffer of pH 3.61, which was extracted into chloroform and investigated at 420 nm. For the second method (method B) the drug-dye ion-pair was broken in alkaline KOH medium, and the resulting free dye color was measured at 610 nm. All variables were studied to optimize the reaction conditions. The regression analysis of Beer's law plots showed good correlation in the concentration ranges of 1-10 and 0.1-2.0 μg/mL for method A and method B, respectively. Molar absorptivity values were 2.99 × 104, and 1.51×105 L/(mol × cm) for measurements by these methods. The methods were also validated for limits of detection (LOD) and quantifi cation (LOQ), intra-day and inter-day accuracy and precision, selectivity, robustness and ruggedness. The composition of the ion-pair (drug-dye) used in the method A was found to be 1:1 by both mole-ratio and Job's methods. The developed methods were applied to tablets, and the results were in good agreement with the label claim and those of the reference method. Because of its high sensitivity, method A was applied to spiked human urine with percent recoveries in the range 96.58-107.3 and a standard deviation <2%.

  8. Design, manufacture and factory testing of the Ion Source and Extraction Power Supplies for the SPIDER experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bigi, Marco, E-mail: marco.bigi@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Rinaldi, Luigi [OCEM Energy Technology, Via della Solidarietà 2/1, 40056 Valsamoggia (località Crespellano), Bologna (Italy); Simon, Muriel [Fusion for Energy, Josep Pla 2, 08019 Barcelona (Spain); Sita, Luca; Taddia, Giuseppe; Carrozza, Saverino [OCEM Energy Technology, Via della Solidarietà 2/1, 40056 Valsamoggia (località Crespellano), Bologna (Italy); Decamps, Hans [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul lez Durance (France); Luchetta, Adriano [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Meddour, Abdelraouf [HIMMELWERK Hoch- und Mittelfrequenzanlagen GmbH, Jopestr. 10, 72072 Tübingen (Germany); Moressa, Modesto [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Morri, Cristiano; Musile Tanzi, Antonio [OCEM Energy Technology, Via della Solidarietà 2/1, 40056 Valsamoggia (località Crespellano), Bologna (Italy); Recchia, Mauro [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Wagner, Uwe [HIMMELWERK Hoch- und Mittelfrequenzanlagen GmbH, Jopestr. 10, 72072 Tübingen (Germany); Zamengo, Andrea; Toigo, Vanni [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy)

    2015-10-15

    Highlights: • 5 MVA ion source power supplies effectively integrated in 150 m{sup 2} Faraday cage. • Load protection and performance requirements met of custom design high voltage power supplies. • 200 kW tetrode oscillator with 200 kHz frequency range successfully tested. - Abstract: The SPIDER experiment, currently under construction at the Neutral Beam Test Facility in Padua, Italy, is a full-size prototype of the ion source for the ITER Neutral Beam Injectors. The Ion Source and Extraction Power Supplies (ISEPS) for SPIDER are supplied by OCEM Energy Technology s.r.l. (OCEM) under a procurement contract with Fusion for Energy (F4E) covering also the units required for MITICA and ITER injectors. The detailed design of SPIDER ISEPS was finalized in 2011 and manufacture of most components completed by end 2013. The Factory Acceptance Tests took place early 2014. ISEPS, with an overall power rating of 5 MVA, form a heterogeneous set of items including solid state power converters and 1 MHz radiofrequency generators of 200 kW output power. The paper presents the main features of the detailed design developed by OCEM, focusing in particular on the high output voltage pulse step modulators, the high output current resonant converters, the radiofrequency generators by HIMMELWERK GmbH and the architecture and implementation of the complex control system. Details are given on non-standard factory tests verifying the insulation requirements specific to this application. Performance of ISEPS during the factory acceptance tests is described, with emphasis on demonstration of the load protection requirements, a crucial point for all neutral beam power supplies. Finally, key dates of SPIDER ISEPS installation and site testing schedule are provided.

  9. System upgradation for surface mode negative ion beam extraction experiments in ROBIN

    International Nuclear Information System (INIS)

    Pandya, Kaushal; Bansal, Gourab; Gahlaut, Agrajit; Soni, Jignesh; Yadav, Ratnakar K.; Mahesh, Vuppugalla; Tyagi, Himanshu; Parmar, KanuG.; Mistri, Hiren; Bhagora, Jighesh; Prajapati, Bhavesh; Patel, Kartik; Bhuyan, Manas; Gouswami, Mehul; Bandyopadhyay, Mainak; Chakraborty, Arun K.

    2017-01-01

    Operational commissioning of ROBIN forms an important milestone in the Indian programme on the R&D on negative ion beams. The commissioning activity has been effected in sequence, in synchronisation with the availability of High voltage Power Supply (HVPS) systems and routine operation has now been established in the cesiated, surface mode. Significant efforts have been placed in upgrading the system to initiate the surface mode operation. These include incorporation of a temperature controlled Cesium (Cs) delivery system, spectroscopic diagnostics for detection of Cs lines, installation of plasma grid heating and closed loop warm water circuit for source components heating and Doppler Shift Spectroscopy (DSS) system. The specific design and integration features for these upgrades are discussed and preliminary results obtained from the operation of ROBIN in the surface mode are presented.

  10. Numerical design of an EBIS collector to optimize electron collection and ion extraction

    International Nuclear Information System (INIS)

    Dietrich, J.

    1990-01-01

    For the Frankfurt EBIS, a new collector was designed using the relativistic electron optics program EGUN and the magnetic field program INTMAG. To model the fringing field of the main solenoid, a bucking coil and a cylindrical shim is provided. The current of the bucking coil and the position and shape of the shim are optimized with INTMAG for minimum fringing field to allow expansion of the electron beam by its space charge. The magnetic field data output from INTMAG is directly used as input for EGUN to calculate the ectron and ion trajectories. The initial conditions for the trajectories were computed from the paraxial ray equation. Different operation modes of the collector are investigated including the behaviour of secondary electrons. (orig.)

  11. Numerical design of an EBIS collector to optimize electron collection and ion extraction

    Science.gov (United States)

    Dietrich, Jürgen

    1990-12-01

    For the Frankfurt EBIS (R. Becker et al., Nucl. Instr. and Meth. B24/25 (1987) 838, ref. [1]), a new collector was designed using the relativistic electron optics program EGUN (W.B. Herrmannsfeldt, SLAC-331 (1988), ref. [2]) and the magnetic field program INTMAG (R. Becker, Nucl. Instr. and Meth. B42 (1989) 303, ref. [3]). To model the fringing field of the main solenoid, a bucking coil and a cylindrical shim is provided. The current of the bucking coil and the position and shape of the shim are optimized with INTMAG for minimum fringing field to allow expansion of the electron beam by its space charge. The magnetic field data output from INTMAG is directly used as input for EGUN to calculate the electron and ion trajectories. The initial conditions for the trajectories were computed from the paraxial ray equation. Different operation modes of the collector are investigated including the behaviour of secondary electrons.

  12. Numerical design of an EBIS collector to optimize electron collection and ion extraction

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, J. (Frankfurt Univ. (Germany, F.R.). Inst. fuer Angewandte Physik)

    1990-12-01

    For the Frankfurt EBIS, a new collector was designed using the relativistic electron optics program EGUN and the magnetic field program INTMAG. To model the fringing field of the main solenoid, a bucking coil and a cylindrical shim is provided. The current of the bucking coil and the position and shape of the shim are optimized with INTMAG for minimum fringing field to allow expansion of the electron beam by its space charge. The magnetic field data output from INTMAG is directly used as input for EGUN to calculate the ectron and ion trajectories. The initial conditions for the trajectories were computed from the paraxial ray equation. Different operation modes of the collector are investigated including the behaviour of secondary electrons. (orig.).

  13. System upgradation for surface mode negative ion beam extraction experiments in ROBIN

    Energy Technology Data Exchange (ETDEWEB)

    Pandya, Kaushal, E-mail: kpandya@ipr.res.in [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India); Bansal, Gourab; Gahlaut, Agrajit; Soni, Jignesh [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India); Yadav, Ratnakar K. [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Mahesh, Vuppugalla [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India); Tyagi, Himanshu [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Parmar, KanuG.; Mistri, Hiren [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India); Bhagora, Jighesh [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Prajapati, Bhavesh; Patel, Kartik [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India); Bhuyan, Manas [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Gouswami, Mehul [Bhakti Management Services, Gandhinagar, 382007, Gujarat (India); Bandyopadhyay, Mainak [ITER-India, Institute for Plasma Research, Gandhinagar, Gujarat (India); Chakraborty, Arun K. [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, 382428, Gujarat (India)

    2017-01-15

    Operational commissioning of ROBIN forms an important milestone in the Indian programme on the R&D on negative ion beams. The commissioning activity has been effected in sequence, in synchronisation with the availability of High voltage Power Supply (HVPS) systems and routine operation has now been established in the cesiated, surface mode. Significant efforts have been placed in upgrading the system to initiate the surface mode operation. These include incorporation of a temperature controlled Cesium (Cs) delivery system, spectroscopic diagnostics for detection of Cs lines, installation of plasma grid heating and closed loop warm water circuit for source components heating and Doppler Shift Spectroscopy (DSS) system. The specific design and integration features for these upgrades are discussed and preliminary results obtained from the operation of ROBIN in the surface mode are presented.

  14. Pitting corrosion resistance of a novel duplex alloy steel in alkali-activated slag extract in the presence of chloride ions

    Science.gov (United States)

    Shi, Jin-jie; Ming, Jing; Liu, Xin

    2017-10-01

    In this study, two types of reinforcing steels (conventional low-carbon steel and a novel duplex alloy steel with Cr and Mo) were exposed to chloride-contaminated extract solutions (ordinary Portland cement (OPC) extract and alkali-activated slag (AAS) extract) to investigate their pitting corrosion resistance. The results confirm that the pitting corrosion resistance of the alloy steel is much higher than that of the low-carbon steel in both extract solutions with various NaCl concentrations. Moreover, for each type of steel, the AAS extract contributes to a higher pitting corrosion resistance compared with the OPC extract in the presence of chloride ions, likely because of the formation of flocculent precipitates on the steel surface.

  15. Equilibrium Studies on the Extraction of Yttrium from Chloride Medium by Mono (2-Ethylhexyl) 2-Ethylhexyl Phosphonic Acid (Ion quest 801)

    International Nuclear Information System (INIS)

    Zaki, E.E.; Ismail, Z.H.; Aly, H.F.; Sabet, S.A.

    2008-01-01

    Since 90 Y is one of the useful radioisotopes in nuclear medicine, liquid-liquid extraction of yttrium from chloride medium has been studied under various conditions using neutralized and un-neutralized mono (2-ethylhexyl) 2-ethylhexyl phosphonic acid (EHEHPA) as an extractant. Effect of reagent concentration, ph of the aqueous medium, metal ion concentration and nature of the diluent on the extraction process has been carried out. Effect of temperature was studied and thermodynamic parameters were evaluated. Yttrium extracted in organic phase was stripped with various reagents. The stoichiometry of the extracted species of yttrium was determined on the basis of slope analysis of experimental results. Equilibrium equations of the extraction process have been estimated and verified

  16. Apparatus for extraction and separation of a preferentially photo-dissociated molecular isotope into positive and negative ions by means of an electric field

    International Nuclear Information System (INIS)

    Fletcher, J.C.

    1978-01-01

    Apparatus for the separation and extraction of molecular isotopes is claimed. Molecules of one and the same isotope are preferentially photo-dissociated by a laser and an ultraviolet source, or by multi-photon absorption of laser radiation. The resultant ions are confined with a magnetic field, moved in opposite directions by an electric field, extracted from the photo-dissociation region by means of screening and accelerating grids, and collected in ducts

  17. Solvent extraction of anionic chelate complexes of lanthanum(III), europium(III), lutetium(III), scandium(III), and indium(III) with 2-thenoyltrifluoroacetone as ion-pairs with tetrabutylammonium ions

    International Nuclear Information System (INIS)

    Noro, Junji; Sekine, Tatsuya.

    1992-01-01

    The solvent extraction of lanthanum(III), europium(III), lutetium(III), scandium(III), and indium(III) in 0.1 mol dm -3 sodium nitrate solutions with 2-thenoyltrifluoroacetone (Htta) in the absence and presence of tetrabutylammonium ions (tba + ) into carbon tetrachloride was measured. The extraction of lanthanum(III), europium(III), and lutetium(III) was greatly enhanced by the addition of tba + ; this could be explained in terms of the extraction of a ternary complex, M(tta) 4 - tba + . However, the extractions of scandium(III) and indium(III) were nearly the same when tba + was added. The data were treated on the basis of the formation equilibrium of the ternary complex from the neutral chelate, M(tta) 3 , with the extracted ion-pairs of the reagents, tta - tba + , in the organic phase. It was concluded that the degree of association of M(tta) 3 with the ion-pair, tta - tba + , is greater in the order La(tta) 3 ≅ Eu(tta) 3 > Lu(tta) 3 , or that the stability of the ternary complex in the organic phase is higher in the order La(tta) 4 - tba + ≅ Eu(tta) 4 - tba + > Lu(tta) 4 - tba + . This is similar to those of adduct metal chelates of Htta with tributylphosphate (TBP) in synergistic extraction systems. (author)

  18. Investigation into the behavior of metal-argon polyatomic ions (MAr+) in the extraction region of inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Ebert, Chris H.; Witte, Travis M.; Houk, R.S.

    2012-01-01

    The abundances of metal-argon polyatomic ions (MAr + ) are determined in inductively coupled plasma-mass spectrometry (ICP-MS). The ratios of MAr + abundance to that for M + ions are measured experimentally. These ratios are compared to expected values, calculated for typical plasma conditions using spectroscopic data. For all metals studied (Ti, V, Cr, Mn, Fe, Co, Ni, Cu, and Zn), the measured ratios are significantly lower than the calculated ratios. Increasing the plasma potential (and thereby increasing the ion kinetic energy) by means of a homemade guard electrode with a wide gap further reduces the MAr + /M + ratio. Implementing a skimmer cone designed for high transmission of light ions increases the MAr + abundance. Considering this evidence, the scarcity of MAr + ions is attributed to collision induced dissociation (CID), likely due to a shock wave at the tip of or in the throat of the skimmer cone. - Highlights: ► MAr + ions are less abundant in the mass spectrum than expected from the ICP. ► Increasing the plasma potential reduces their abundance further. ► The extraction lens voltage does not greatly affect the MAr + abundances. ► The weakly-bound MAr + ions are probably dissociated by collisions during extraction.

  19. Source fabrication and lifetime for Li+ ion beams extracted from alumino-silicate sources

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W

    2012-03-05

    A space-charge-limited beam with current densities (J) exceeding 1 mA/cm2 have been measured from lithium alumino-silicate ion sources at a temperature of ~1275 °C. At higher extraction voltages, the source appears to become emission limited with J ≥ 1.5 mA/cm2, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, ≤0.25 mm thick, has a measured lifetime of ~40 h at ~1275 °C, when pulsed at 0.05 Hz and with pulse length of ~6 μs each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. Finally, the source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

  20. Source fabrication and lifetime for Li+ ion beams extracted from alumino-silicate sources

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W.

    2012-04-01

    A space-charge-limited beam with current densities (J) exceeding 1 mA/cm2 have been measured from lithium alumino-silicate ion sources at a temperature of ~1275 °C. At higher extraction voltages, the source appears to become emission limited with J ≥ 1.5 mA/cm2, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, ≤0.25 mm thick, has a measured lifetime of ~40 h at ~1275 °C, when pulsed at 0.05 Hz and with pulse length of ~6 μs each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. Finally, the source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

  1. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    Science.gov (United States)

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Recognition and extraction of cesium hydroxide and carbonate by using a neutral multitopic ion-pair receptor

    Energy Technology Data Exchange (ETDEWEB)

    He, Qing; Peters, Gretchen Marie; Lynch, Vincent M.; Sessler, Jonathan L. [Department of Chemistry, University of Texas, Austin, TX (United States)

    2017-10-16

    Current approaches to lowering the pH of basic media rely on the addition of a proton source. An alternative approach is described herein that involves the liquid-liquid extraction-based removal of cesium salts, specifically CsOH and Cs{sub 2}CO{sub 3}, from highly basic media. A multitopic ion-pair receptor (2) is used that can recognize and extract the hydroxide and carbonate anions as their cesium salts, as confirmed by {sup 1}H NMR spectroscopic titrations, ICP-MS, single-crystal structural analyses, and theoretical calculations. A sharp increase in the pH and cesium concentrations in the receiving phase is observed when receptor 2 is employed as a carrier in U-tube experiments involving the transport of CsOH through an intervening chloroform layer. The pH of the source phase likewise decreases. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Ion-channel genosensor for the detection of specific DNA sequences derived from Plum Pox Virus in plant extracts.

    Science.gov (United States)

    Malecka, Kamila; Michalczuk, Lech; Radecka, Hanna; Radecki, Jerzy

    2014-10-09

    A DNA biosensor for detection of specific oligonucleotides sequences of Plum Pox Virus (PPV) in plant extracts and buffer is proposed. The working principles of a genosensor are based on the ion-channel mechanism. The NH2-ssDNA probe was deposited onto a glassy carbon electrode surface to form an amide bond between the carboxyl group of oxidized electrode surface and amino group from ssDNA probe. The analytical signals generated as a result of hybridization were registered in Osteryoung square wave voltammetry in the presence of [Fe(CN)6]3-/4- as a redox marker. The 22-mer and 42-mer complementary ssDNA sequences derived from PPV and DNA samples from plants infected with PPV were used as targets. Similar detection limits of 2.4 pM (31.0 pg/mL) and 2.3 pM (29.5 pg/mL) in the concentration range 1-8 pM were observed in the presence of the 22-mer ssDNA and 42-mer complementary ssDNA sequences of PPV, respectively. The genosensor was capable of discriminating between samples consisting of extracts from healthy plants and leaf extracts from infected plants in the concentration range 10-50 pg/mL. The detection limit was 12.8 pg/mL. The genosensor displayed good selectivity and sensitivity. The 20-mer partially complementary DNA sequences with four complementary bases and DNA samples from healthy plants used as negative controls generated low signal.

  4. Tripodal (N-alkylated) CMP(O) and malonamide ligands: synthesis, extraction of metal ions, and potentiometric studies

    Energy Technology Data Exchange (ETDEWEB)

    Janczewski, D.; Reinhoudt, D.N.; Verboom, W. [Twente Univ., Lab. of Supramolecular Chemistry and Technology, Mesa Research Institute for Nanotechnology, Enschede (Netherlands); Malinowska, E.; Pietrzak, M. [Warsaw Univ. of Technology, Dept. of Analytical Chemistry, Faculty of Chemistry (Poland); Hill, C.; Allignol, C. [CEA Valrho, 30 - Marcoule (France)

    2007-01-15

    Tripodal ligands build on the C-pivot (9b-e, 13b-d, and 17a-d) and tri-alkyl-benzene platforms (10a,b, 11, 12, 14a,b, and 18a,b) bearing (N-alkylated) carbamoyl-methyl-phosphine oxide (CMPO), carbamoyl-methyl-phosphonate (CMP), and malonamide moieties were synthesized. Extraction studies with Am{sup 3+} and Eu{sup 3+} show that in general there is a positive influence of the N-alkyl substituents in C-pivot CMP(O) ligands on the D(distribution) coefficients. The tri-alkyl-benzene CMPO ligands 10a,b, 11, and 12 have considerably larger D coefficients than the corresponding C-pivot analogues 9a-e, although hardly having any selectivity, while N-alkylation gives rise to smaller D coefficients. Although less effective the extraction behavior of the C-pivot CMP analogues 13b-d shows more or less the same trend as the corresponding CMPO ligands 9b-e upon substitution of the carboxamide N-atom with different alkyl chains. The different malonamide ligands 17a-d and 18a,b are bad extractants, while N-alkylation makes them even worse. Potentiometric studies of CMP(O) and malonamide ligands in polymeric membranes on Pb{sup 2+}, Cu{sup 2+}, Ca{sup 2+}, Mg{sup 2+}, Na{sup +}, and K{sup +} salts revealed that N-alkyl substituents increase the stability constants of ion-ionophore complexes compared to unsubstituted ligands. In polymeric membrane electrodes the ligands induce a selectivity pattern that differs significantly from the so-called Hofmeister series, giving the highest selectivity coefficients for UO{sub 2}{sup 2+} among all examined cations (Pb{sup 2+}, Cu{sup 2+}, Ca{sup 2+}, Mg{sup 2+}, Na{sup +}, K{sup +}). (authors)

  5. Tripodal (N-alkylated) CMP(O) and malonamide ligands: synthesis, extraction of metal ions, and potentiometric studies

    International Nuclear Information System (INIS)

    Janczewski, D.; Reinhoudt, D.N.; Verboom, W.; Malinowska, E.; Pietrzak, M.; Hill, C.; Allignol, C.

    2007-01-01

    Tripodal ligands build on the C-pivot (9b-e, 13b-d, and 17a-d) and tri-alkyl-benzene platforms (10a,b, 11, 12, 14a,b, and 18a,b) bearing (N-alkylated) carbamoyl-methyl-phosphine oxide (CMPO), carbamoyl-methyl-phosphonate (CMP), and malonamide moieties were synthesized. Extraction studies with Am 3+ and Eu 3+ show that in general there is a positive influence of the N-alkyl substituents in C-pivot CMP(O) ligands on the D(distribution) coefficients. The tri-alkyl-benzene CMPO ligands 10a,b, 11, and 12 have considerably larger D coefficients than the corresponding C-pivot analogues 9a-e, although hardly having any selectivity, while N-alkylation gives rise to smaller D coefficients. Although less effective the extraction behavior of the C-pivot CMP analogues 13b-d shows more or less the same trend as the corresponding CMPO ligands 9b-e upon substitution of the carboxamide N-atom with different alkyl chains. The different malonamide ligands 17a-d and 18a,b are bad extractants, while N-alkylation makes them even worse. Potentiometric studies of CMP(O) and malonamide ligands in polymeric membranes on Pb 2+ , Cu 2+ , Ca 2+ , Mg 2+ , Na + , and K + salts revealed that N-alkyl substituents increase the stability constants of ion-ionophore complexes compared to unsubstituted ligands. In polymeric membrane electrodes the ligands induce a selectivity pattern that differs significantly from the so-called Hofmeister series, giving the highest selectivity coefficients for UO 2 2+ among all examined cations (Pb 2+ , Cu 2+ , Ca 2+ , Mg 2+ , Na + , K + ). (authors)

  6. Solvent extraction separations of trivalent lanthanide and actinide ions using an aqueous aminomethanediphosphonic acid

    International Nuclear Information System (INIS)

    Jensen, M. P.

    1998-01-01

    The possibility of separating the trivalent lanthanides, represented by EU 3+ , and actinides, represented by Cf 3+ , using HDEHP in toluene and an aqueous phase containing N-piperidinomethane-1,1-diphosphotic acid, PMDPA, has been investigated. This modified aqueous phase offers potential advantages over the diethylenetriaminepentaacetic acid based TALSPEAK process because of the improved complexation properties of PMDPA in acidic solutions, and the ability to decompose PMDPA before disposal. Extraction experiments were conducted at 25 C in 2 M NaClO 4 between -log [H + ] 1 and 2. The studies enabled us to derive the aqueous phase speciation, the stability constants of the aqueous complexes, and the Cf/Eu separation factors. Despite the presence of an amino group in PMDPA that should favor the retention of the actinides in the aqueous phase, the Cf/Eu separation factors are near unity under the conditions studied

  7. Stratified systems without organic solvent - new extraction type of macro- and microquantities of metal ions

    International Nuclear Information System (INIS)

    Dyogtev, M.I.; Alikina, E.N.; Popova, O.N.; Amindjanov, A.A.

    2012-01-01

    This article describes the results of studies on solubility in four component systems: di anti pyril methane-benzoic (salicylic) acid-HCl-H 2 O, hexyl di anti pyril methane-benzoic (salicylic) acid-HCl-H 2 O at 298 and 323 K. It is defined that stable stratification appears by addition of hydrochloric acid in the concentration range of 3.0-4.9 wt.% HCl. At substitution of di anti pyril methane on hexyl di anti pyril methane the wide range of stratification in the cut of hexyl di anti pyril methane-benzoic (salicylic) acid - 5 wt.% HCl is observes. The possibility of using of stratified systems for quantitative extraction of copper, cadmium, iron, thallium and tin is proposed.

  8. Coincident ion acceleration and electron extraction for space propulsion using the self-bias formed on a set of RF biased grids bounding a plasma source

    International Nuclear Information System (INIS)

    Rafalskyi, D; Aanesland, A

    2014-01-01

    We propose an alternative method to accelerate ions in classical gridded ion thrusters and ion sources such that co-extracted electrons from the source may provide beam space charge neutralization. In this way there is no need for an additional electron neutralizer. The method consists of applying RF voltage to a two-grid acceleration system via a blocking capacitor. Due to the unequal effective area of the two grids in contact with the plasma, a dc self-bias is formed, rectifying the applied RF voltage. As a result, ions are continuously accelerated within the grid system while electrons are emitted in brief instants within the RF period when the RF space charge sheath collapses. This paper presents the first experimental results and a proof-of-principle. Experiments are carried out using the Neptune thruster prototype which is a gridded Inductively Coupled Plasma (ICP) source operated at 4 MHz, attached to a larger beam propagation chamber. The RF power supply is used both for the ICP discharge (plasma generation) and powering the acceleration grids via a capacitor for ion acceleration and electron extraction without any dc power supplies. The ion and electron energies, particle flux and densities are measured using retarding field energy analyzers (RFEA), Langmuir probes and a large beam target. The system operates in Argon and N 2 . The dc self-bias is found to be generated within the gridded extraction system in all the range of operating conditions. Broad quasi-neutral ion-electron beams are measured in the downstream chamber with energies up to 400 eV. The beams from the RF acceleration method are compared with classical dc acceleration with an additional external electron neutralizer. It is found that the two acceleration techniques provide similar performance, but the ion energy distribution function from RF acceleration is broader, while the floating potential of the beam is lower than for the dc accelerated beam. (paper)

  9. Transverse spin physics

    CERN Document Server

    Barone, Vicenzo

    2001-01-01

    This book is devoted to the theory and phenomenology of transverse-spin effects in high-energy hadronic physics. Contrary to common past belief, it is now rather clear that such effects are far from irrelevant. A decade or so of intense theoretical work has shed much light on the subject and brought to surface an entire class of new phenomena, which now await thorough experimental investigation. Over the next few years a number of experiments world-wide (at BNL, CERN, DESY and JLAB) will run with transversely polarised beams and targets, providing data that will enrich our knowledge of the tra

  10. Transverse betatron tune measurements

    International Nuclear Information System (INIS)

    Serio, M.

    1989-01-01

    In this paper the concept of the betatron tune and the techniques to measure it are discussed. The smooth approximation is introduced along with the terminology of betatron oscillations, phase advance and tune. Single particle and beam spectra in the presence of synchro-betatron oscillations are treated with emphasis on the consequences of sampling the beam position. After a general presentation of various kinds of beam position monitors and transverse kickers, the time domain and frequency domain analysis of the beam response to a transverse excitation are discussed and several methods and applications of the tune measurements are listed

  11. Strange hadron production at low transverse momenta

    Science.gov (United States)

    Veres, Gábor I.; PHOBOS Collaboration; Back, B. B.; Baker, M. D.; Ballintijn, M.; Barton, D. S.; Becker, B.; Betts, R. R.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Decowski, M. P.; García, E.; Gburek, T.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Harrington, A. S.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Holynski, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Khan, N.; Kulinich, P.; Kuo, C. M.; Lee, J. W.; Lin, W. T.; Manly, S.; Mignerey, A. C.; Noell, A.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Roland, C.; Roland, G.; Sagerer, J.; Sarin, P.; Sawicki, P.; Sedykh, I.; Skulski, W.; Smith, C. E.; Steinberg, P.; Stephans, G. S. F.; Sukhanov, A.; Teng, R.; Tonjes, M. B.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wyslouch, B.; Zhang, J.

    2004-01-01

    Some of the latest results of the PHOBOS experiment from the \\sqrt{s_{NN}}= 200\\ GeV Au+Au data are discussed. Those relevant to strangeness production are emphasized. These observations relate to the nature of the matter created when heavy ions collide at the highest achieved energy. The invariant yields of strange and non-strange charged hadrons at very low transverse momentum have been measured, and used to differentiate between different dynamical scenarios. In the intermediate transverse momentum range, the measured ratios of strange and anti-strange kaons approach one, while the antibaryon to baryon ratio is still significantly less, independent of collision centrality and transverse momentum. At high transverse momenta, we find that central and peripheral Au+Au collisions produce similar numbers of charged hadrons per participant nucleon pair, rather than per binary nucleon-nucleon collision. Finally, we describe the upgrades of PHOBOS completed for the 2003 d+Au and p+p run, which extend the transverse momentum range over which particle identification is possible and, at the same time, implement a trigger system selective for high-pT particles.

  12. Confinement of laser plasma by solenoidal field for laser ion source

    International Nuclear Information System (INIS)

    Okamura, M.; Kanesue, T.; Kondo, K.; Dabrowski, R.

    2010-01-01

    A laser ion source can provide high current, highly charged ions with a simple structure. However, it was not easy to control the ion pulse width. To provide a longer ion beam pulse, the plasma drift length, which is the distance between laser target and extraction point, has to be extended and as a result the plasma is diluted severely. Previously, we applied a solenoid field to prevent reduction of ion density at the extraction point. Although a current enhancement by a solenoid field was observed, plasma behavior after a solenoid magnet was unclear because plasma behavior can be different from usual ion beam dynamics. We measured a transverse ion distribution along the beam axis to understand plasma motion in the presence of a solenoid field.

  13. Use of nuclear filters in the determination of thorium with previous separation by precipitation with fluoride ions and latter liquid-liquid extraction with TOPO

    International Nuclear Information System (INIS)

    Estevez, J.; Betancourt, M.

    1988-01-01

    A method for the determination of thorium in phosphorites, that includes a previous separation of some interfering elements was elaborated. Thorium was precipitated with fluoride ions and the insoluble compound formed was separated by using nuclear filters. Latter and extraction was made with Xilene-TOPO and colour was developed with Ars III in organic phase. 19 refs

  14. Hypereosinophilic Atopic Transverse Myelitis

    African Journals Online (AJOL)

    2018-06-11

    4 days ago ... Atopic transverse myelitis is a rare disorder that is defined as a ... was commenced on prednisolone and had good response to treatment. .... Atopic myelitis is more common in male sex such as .... their identity, but anonymity cannot be guaranteed. ... useful diagnostic clue in surgical neuropathology.

  15. Noninterceptive transverse beam diagnostics

    International Nuclear Information System (INIS)

    Chamberlin, D.D.; Minerbo, G.N.; Teel, L.E. Jr.; Gilpatrick, J.D.

    1981-01-01

    The transverse emittance properties of a high-current linear accelerator may be measured by using TV cameras sensitive to the visible radiation emitted following beam interactions with residual gas. This paper describes the TV system being used to measure emittances for the Fusion Materials Irradiation Test (FMIT) project

  16. Transversally extended string

    International Nuclear Information System (INIS)

    Akama, Keiichi

    1988-01-01

    Starting with the space-time action of the transversally extended string, we derive its world-sheet action, which is that of a gravitational and gauge theory with matter fields on the world-sheet, with additional effects of the second fundamental quantity. (author)

  17. Determination of trace labile copper in environmental waters by magnetic nanoparticle solid phase extraction and high-performance chelation ion chromatography.

    Science.gov (United States)

    Wei, Z; Sandron, S; Townsend, A T; Nesterenko, P N; Paull, B

    2015-04-01

    Cobalt magnetic nanoparticles surface functionalised with iminodiacetic acid were evaluated as a nano-particulate solid phase extraction absorbent for copper ions (Cu(2+)) from environmental water samples. Using an external magnetic field, the collector nanoparticles could be separated from the aqueous phase, and adsorbed ions simply decomplexed using dilute HNO3. Effects of pH, buffer concentration, sample and sorbent volume, extraction equilibrium time, and interfering ion concentration on extraction efficiency were investigated. Optimal conditions were then applied to the extraction of Cu(2+) ions from natural water samples, prior to their quantitation using high-performance chelation ion chromatography. The limits of detection (LOD) of the combined extraction and chromatographic method were ~0.1 ng ml(-1), based upon a 100-fold preconcentration factor (chromatographic performance; LOD=9.2 ng ml(-1) Cu(2+)), analytical linear range from 20 to 5000 ng mL(-1), and relative standard deviations=4.9% (c=1000 ng ml(-1), n=7). Accuracy and precision of the combined approach was verified using a certified reference standard estuarine water sample (SLEW-2) and comparison of sample determinations with sector field inductively coupled plasma mass spectrometry. Recoveries from the addition of Cu(2+) to impacted estuarine and rain water samples were 103.5% and 108.5%, respectively. Coastal seawater samples, both with and without prior UV irradiation and dissolved organic matter removal were also investigated using the new methodology. The effect of DOM concentration on copper availability was demonstrated. Copyright © 2015. Published by Elsevier B.V.

  18. Nucleon Spin Structure: Longitudinal and Transverse

    International Nuclear Information System (INIS)

    Chen, Jian-Ping

    2011-01-01

    Inclusive Deep-Inelastic Scattering (DIS) experiments have provided us with the most extensive information on the unpolarized and longitudinal polarized parton (quark and gluon) distributions in the nucleon. It has becoming clear that transverse spin and transverse momentum dependent distributions (TMDs) study are crucial for a more complete understanding of the nucleon structure and the dynamics of the strong interaction. The transverse spin structure and the TMDs are the subject of increasingly intense theoretical and experimental study recently. With a high luminosity electron beam facility, JLab has played a major role in the worldwide effort to study both the longitudinal and transverse spin structure. Highlights of recent results will be presented. With 12-GeV energy upgrade, JLab will provide the most precise measurements in the valence quark region to close a chapter in longitudinal spin study. JLab will also perform a multi-dimensional mapping of the transverse spin structure and TMDs in the valence quark region through Semi-Inclusive DIS (SIDIS) experiments, providing a 3-d partonic picture of the nucleon in momentum space and extracting the u and d quark tensor charges of the nucleon. The precision mapping of TMDs will also allow a detailed study of the quark orbital motion and its dynamics.

  19. PIXiE: an algorithm for automated ion mobility arrival time extraction and collision cross section calculation using global data association

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Jian; Casey, Cameron P.; Zheng, Xueyun; Ibrahim, Yehia M.; Wilkins, Christopher S.; Renslow, Ryan S.; Thomas, Dennis G.; Payne, Samuel H.; Monroe, Matthew E.; Smith, Richard D.; Teeguarden, Justin G.; Baker, Erin S.; Metz, Thomas O.

    2017-05-15

    Motivation: Drift tube ion mobility spectrometry (DTIMS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS coupled with mass spectrometry and compute their associated collisional cross sections (CCS) we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of information necessary to create a reference library containing accu-rate masses, DTIMS arrival times and CCSs for use in high throughput omics analyses. Results: We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were identical to those calculated by hand and within error of those calcu-lated using commercially available instrument vendor software.

  20. Development of the front end test stand and vessel for extraction and source plasma analyses negative hydrogen ion sources at the Rutherford Appleton Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Lawrie, S. R., E-mail: scott.lawrie@stfc.ac.uk [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell Oxford, Harwell (United Kingdom); John Adams Institute of Accelerator Science, University of Oxford, Oxford (United Kingdom); Faircloth, D. C.; Letchford, A. P.; Perkins, M.; Whitehead, M. O.; Wood, T. [STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory, Harwell Oxford, Harwell (United Kingdom); Gabor, C. [ASTeC Intense Beams Group, Rutherford Appleton Laboratory, Harwell Oxford, Harwell (United Kingdom); Back, J. [High Energy Physics Department, University of Warwick, Coventry (United Kingdom)

    2014-02-15

    The ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK uses a Penning surface plasma negative hydrogen ion source. Upgrade options for the ISIS accelerator system demand a higher current, lower emittance beam with longer pulse lengths from the injector. The Front End Test Stand is being constructed at RAL to meet the upgrade requirements using a modified ISIS ion source. A new 10% duty cycle 25 kV pulsed extraction power supply has been commissioned and the first meter of 3 MeV radio frequency quadrupole has been delivered. Simultaneously, a Vessel for Extraction and Source Plasma Analyses is under construction in a new laboratory at RAL. The detailed measurements of the plasma and extracted beam characteristics will allow a radical overhaul of the transport optics, potentially yielding a simpler source configuration with greater output and lifetime.

  1. Ion-acoustic waves and drift waves in negative ion sources

    International Nuclear Information System (INIS)

    Gerwin, R.A.

    1989-01-01

    Attention is directed towards instabilities induced in hydrogen plasmas due to the presence of the desired H/sup /minus// ions. Preliminary investigations indicate that when the electron temperature exceeds the temperature of the background ions (H + ), the H/sup /minus// beam causes collective instabilities even at very low (even vanishing) beam velocities, provided that the non-ideal properties of the background plasma are taken into consideration. The most dangerous instabilities involve oscillations transverse to the direction of beam extraction, and may thereby degrade the beam emittance. 5 refs

  2. Pellitorine, an extract of Tetradium daniellii, is an antagonist of the ion channel TRPV1.

    Science.gov (United States)

    Oláh, Zoltán; Rédei, Dóra; Pecze, László; Vizler, Csaba; Jósvay, Katalin; Forgó, Péter; Winter, Zoltán; Dombi, György; Szakonyi, Gerda; Hohmann, Judit

    2017-10-15

    Transient Receptor Potential Vanilloid 1 (TRPV1) confers noxious heat and inflammatory pain signals in the peripheral nervous system. Clinical trial of resiniferatoxin from Euphorbia species is successfully aimed at TRPV1 in cancer pain management and heading toward new selective painkiller status that further validates this target for drug discovery efforts. Evodia species, used in traditional medicine for hundreds of years, are a recognised source of different TRPV1 agonists, but no antagonist has yet been reported. In a search for painkiller leads, we noted for the first time a TRPV1 antagonist activity in the fresh fruits of Tetradium daniellii (Benn.) T.G. Hartley (syn. Evodia hupehensis Dode). Through a combination of extraction and purification methods with functional TRPV1-specific Ca 2+ uptake assays (bioactivity-guided fractionation/isolation/purification); we isolated a new painkiller candidate that is a distant structural homologue of capsiate exovanilloids and endovanilloids such as anandamide, but a putative competitive inhibitor of the TRPV1. Four additional inactive compounds (N-isobutyl-4,5-epoxy-2E-decadienamide, geranylpsoralen, 8-(7',8'-epoxygeranyloxy)psoralen, and xanthotoxol) were also co-purified with pellitorine. Their structures were established by extensive 1D- and 2D-NMR spectroscopic analysis. 1 H- and 13 C NMR determination of the chemical structure revealed it to be pellitorine, (2E,4E)-N-(2-methylpropyl)deca-2,4-dienamide, which can compete structurally with algesics released in inflammation. In contrast to previous isolates from Evodia species, pellitorine blocked capsaicin-evoked Ca 2+ uptake with an IC 50 of 154 µg/ml (0.69 mM/l). N-Isobutyl-4,5-epoxy-2E-decadienamide and geranylpsoralen, 8-(7',8'-epoxygeranyloxy)psoralen, and xanthotoxol did not affect the TRPV1. This is the first evidence that pellitorine, an aliphatic alkylamide analogue of capsaicin, can serve as an antagonist of the TRPV1 and may inhibit exovanilloid

  3. Diaion HP-2MG modified with 2-(2,6-dichlorobenzylideneamino) benzenethiol as new adsorbent for solid phase extraction and flame atomic absorption spectrometric determination of metal ions.

    Science.gov (United States)

    Ghaedi, M; Montazerozohori, M; Haghdoust, S; Zaare, F; Soylak, M

    2013-04-01

    A solid phase extraction method for enrichment-separation and the determination of cobalt (Co(2+)), copper (Cu(2+)), nickel (Ni(2+)), zinc (Zn(2+)) and lead (Pb(2+)) ions in real samples has been proposed. The influences of some analytical parameters like pH, flow rate, eluent type and interference of matrix ions on recoveries of analytes were optimized. The limits of detection were found in the range of 1.6-3.9 µg L(-1), while preconcentration factor for all understudy metal ions were found to be 166 with loading half time (t 1/2) less than 10 min. The procedure was applied for the enrichment-separation of analyte ions in environmental samples with recoveries higher than 94.8% and relative SD <4.9% (N = 5).

  4. Synthesis and characterisation of nano structure lead (II) ion-imprinted polymer as a new sorbent for selective extraction and preconcentration of ultra trace amounts of lead ions from vegetables, rice, and fish samples.

    Science.gov (United States)

    Behbahani, Mohammad; Bagheri, Akbar; Taghizadeh, Mohsen; Salarian, Mani; Sadeghi, Omid; Adlnasab, Laleh; Jalali, Kobra

    2013-06-01

    This paper describes the preparation of new Pb(II)-imprinted polymeric particles using 2-vinylpyridine as a functional monomer, ethylene glycol dimethacrylate as the cross-linker, 2,2'- azobisisobutyronitrile as the initiator, diphenylcarbazone as the ligand, acetonitril as the solvent, and Pb(NO(3))(2) as the template ion, through bulk polymerisation technique. The imprinted lead ions were removed from the polymeric matrix using 5 mL of HCl (2 mol.L(-1)) as the eluting solvent. The lead ion concentration was determined by flame atomic absorption spectrometry. Optimum pH for maximum sorption was obtained at 6.0. Sorption and desorption of Pb(II) ions on the IIP particles were quite fast and achieved fully over 5 min. In the proposed method, the maximum sorbent capacity of the ion-imprinted polymer was calculated to be 75.4 mg g(-1). The preconcentration factor, relative standard deviation, and limit of detection of the method were found to be 245, 2.1%, and 0.42 ng mL(-1), respectively. The prepared ion-imprinted polymer particles have an increased selectivity toward Pb(II) ions over a range of competing metal ions with the same charge and similar ionic radius. This ion-imprinted polymer is an efficient solid phase for extraction and preconcentration of lead ions in complex matrixes. For proving that the proposed method is reliable, a wide range of food samples with different and complex matrixes was used. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Etched ion tracks in silicon oxide and silicon oxynitride as charge injection or extraction channels for novel electronic structures

    International Nuclear Information System (INIS)

    Fink, D.; Petrov, A.V.; Hoppe, K.; Fahrner, W.R.; Papaleo, R.M.; Berdinsky, A.S.; Chandra, A.; Chemseddine, A.; Zrineh, A.; Biswas, A.; Faupel, F.; Chadderton, L.T.

    2004-01-01

    The impact of swift heavy ions onto silicon oxide and silicon oxynitride on silicon creates etchable tracks in these insulators. After their etching and filling-up with highly resistive matter, these nanometric pores can be used as charge extraction or injection paths towards the conducting channel in the underlying silicon. In this way, a novel family of electronic structures has been realized. The basic characteristics of these 'TEMPOS' (=tunable electronic material with pores in oxide on silicon) structures are summarized. Their functionality is determined by the type of insulator, the etch track diameters and lengths, their areal densities, the type of conducting matter embedded therein, and of course by the underlying semiconductor and the contact geometry. Depending on the TEMPOS preparation recipe and working point, the structures may resemble gatable resistors, condensors, diodes, transistors, photocells, or sensors, and they are therefore rather universally applicable in electronics. TEMPOS structures are often sensitive to temperature, light, humidity and organic gases. Also light-emitting TEMPOS structures have been produced. About 37 TEMPOS-based circuits such as thermosensors, photosensors, humidity and alcohol sensors, amplifiers, frequency multipliers, amplitude modulators, oscillators, flip-flops and many others have already been designed and successfully tested. Sometimes TEMPOS-based circuits are more compact than conventional electronics

  6. Novel polymer inclusion membranes containing T2EHDGA as carrier extractant for actinide ion uptake from acidic feeds

    Energy Technology Data Exchange (ETDEWEB)

    Mahanty, Bholanath; Das, Dillip Kumar; Behere, Praveen Gajanan; Afzal, Mohammad [Bhabha Atomic Research Centre, Tarapur, Maharashtra (India). Advanced Fuel Fabrication Facility; Mohapatra, Prasanta Kumar; Raut, Dhaval Ramakant [Bhabha Atomic Research Centre, Trombay, Mumbai (India). Radiochemistry Div.

    2015-06-01

    Polymer inclusion membranes (PIM) containing N,N,N',N'-tetra(2-ethylhexyl) diglycolamide (T2EHDGA) were evaluated for the separation of actinide ions such as Am{sup 3+}, Pu{sup 4+}, UO{sub 2}{sup 2+} and Th{sup 4+} from acidic feeds. The PIMs were prepared using cellulose triacetate (CTA) as the polymer matrix, 2-nitrophenyloctyl ether (NPOE) as the plasticizer and T2EHDGA as the carrier extractant and the optimized membrane composition was found to be 68.4% T2EHDGA, 17.9% NPOE and 13.7% CTA which resulted in 74% Am{sup 3+} uptake at 1 M HNO{sub 3} in 2 h. The uptake studies were carried out using feed solutions containing varying concentrations of nitric acid (0.5-3.0 M) and showed the trend: Pu{sup 4+} > Am{sup 3+} > Th{sup 4+} > UO{sub 2}{sup 2+}. Quantitative stripping (> 99%) of the sorbed Am{sup 3+} was possible using a solution containing 0.01 M EDTA at pH 3.0. Reusability studies indicated deterioration of the PIM on continuous use.

  7. Transverse Spin Physics: Recent Developments

    International Nuclear Information System (INIS)

    Yuan, Feng

    2008-01-01

    Transverse-spin physics has been very active and rapidly developing in the last few years. In this talk, I will briefly summarize recent theoretical developments, focusing on the associated QCD dynamics in transverse spin physics

  8. TWITCH PARAMETERS IN TRANSVERSAL AND LONGITUDINAL BICEPS BRACHII RESPONSE

    Directory of Open Access Journals (Sweden)

    Boštjan Šimunič

    2010-01-01

    Full Text Available Assessment of the contractile properties of skeletal muscles is continuing to be an important issue and a difficult task methodologically. Longitudinal direction of skeletal muscle contraction blurs intrinsic muscle belly contractile properties with many factors. This study evaluates and explains contractile properties such as: delay time (Td, contraction time (Tc, half relaxation time (Tr and maximal amplitude (Dm extracted from twitch transversal response and compare them with torque response. In fifteen healthy males (age 23.7 ± 3.4 years isometric twitch transversal and torque responses were simultaneously recorded during graded electrically elicited contractions in the biceps brachii muscle. The amplitude of electrical stimulation was increased in 5 mA steps from a threshold up to a maximal response. The muscles’ belly transversal response was measured by a high precision mechanical displacement sensor while elbow joint torque was calculated from force readings. Results indicate a parabolic relation between the transversal displacement and the torque Dm. A significantly shorter Tc was found in transversal response without being correlated to torque Tc (r = -0.12; > 0.05. A significant correlation was found between torque Tc and the time occurrence of the second peak in the transversal response (r = 0.83; < 0.001. Electrical stimulation amplitude dependant variation of the Tc was notably different in transversal than in torque response. Td was similar at submaximal and maximal responses but larger in transversal at just above threshold contractions. Tr has a similar linear trend in both responses, however, the magnitude and the slope are much larger in the transversal response. We could conclude that different mechanisms affect longitudinal and transversal twitch skeletal muscle deformations. Contractile properties extracted from the transversal response enable alternative insights into skeletal muscle contraction mechanics.

  9. Large transverse momentum phenomena

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1977-09-01

    It is pointed out that it is particularly significant that the quantum numbers of the leading particles are strongly correlated with the quantum numbers of the incident hadrons indicating that the valence quarks themselves are transferred to large p/sub t/. The crucial question is how they get there. Various hadron reactions are discussed covering the structure of exclusive reactions, inclusive reactions, normalization of inclusive cross sections, charge correlations, and jet production at large transverse momentum. 46 references

  10. Extraction of Some Divalent Metal Ions (Cadmium, Nickel and Lead from Different Tea and Rice Samples Using Ghezeljeh Nanoclay (Geleh-Sar-Shoor as a New Natural Sorbent

    Directory of Open Access Journals (Sweden)

    Zahra Hassanzadeh Siahpoosh

    2016-12-01

    Full Text Available This article presents the method of extraction-preconcentration of Lead, Cadmium, and Nickel ions from food samples using the Ghezeljeh montmorillonite nanoclay (Geleh-Sar-Shoor as a new native adsorbent in batch single component systems. The extraction-preconcentration of heavy metals were carried out by applying the solid phase extraction (SPE method followed by atomic absorption spectroscopy (AAS, and inductively coupled with plasma atomic emission spectroscopy (ICP-AES. The Ghezeljeh nanoclay was characterized by using Fourier transform infrared spectroscopy (FT-IR, Scanning electron microscopy-energy dispersive spectrometer operating (SEM-EDS, X-ray diffractometry (XRD, X-ray fluorescence (XRF, Cation Exchange Capacity (CEC measurements, BET specific surface area and Zeta potential. According to BET theory, the specific surface areas of the Ghezeljeh nanoclay was calculated to be 19.8 m2 g-1 whereas the cation exchange capacity was measured to be 150 meq/100 g. The results of XRD, XRF, FT-IR, Zeta potential and BET surface area of the nanoclay confirmed that montmorillonite was the dominant mineral phase. Based on SEM images of this clay, it can be seen that the distance between the plates is nm level. For all three ions, the detection and quantification limits, dynamic linear range, preconcentration factor, and adsorption capacity were obtained. The effect of various interfering ions was studied. The experimental method was successfully applied for the extraction of heavy metals in different tea and rice samples.

  11. Solid phase extraction of heavy metal ions based on a novel functionalized magnetic multi-walled carbon nanotube composite with the aid of experimental design methodology

    International Nuclear Information System (INIS)

    Taghizadeh, Mohsen; Asgharinezhad, Ali Akbar; Samkhaniany, Noorallah; Tadjarodi, Azadeh; Abbaszadeh, Abolfazl; Pooladi, Mohsen

    2014-01-01

    We report that magnetic multiwalled carbon nanotubes functionalized with 8-aminoquinoline can be applied to the preconcentration of Cd(II), Pb(II) and Ni(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount, and pH value) were selected as the main factors affecting sorption, and four variables (type, volume and concentration of the eluent; elution time) were selected for optimizing elution. Following sorption and elution, the ions were quantified by FAAS. The LODs are 0.09, 0.72, and 1.0 ng mL −1 for Cd(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations are <5.1 % for five separate batch determinations at 30 ng mL −1 level of Cd(II), Ni(II), and Pb(II) ions. The sorption capacities (in mg g −1 ) of this new sorbent are 201 for Cd(II), 150 for Pb(II), and 172 Ni(II). The composite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples. (author)

  12. Transverse tomography and radiotherapy

    International Nuclear Information System (INIS)

    Leer, J.W.H.

    1982-01-01

    This study was intended to delineate the indications for radiotherapy treatment-planning with the help of computerized axial tomography (C.T.) and transverse analog tomography (T.A.T.). Radiotherapy localisation procedures with the conventional method (simulator), with the CT-scanner and with the transverse analog tomograph (T.A.T., Simtomix, Oldelft) were compared. As criterium for evaluation differences in reconstruction drawing based on these methods were used. A certain method was judged ''superior'' to another if the delineation of the target volume was more accurate, if a better impression was gained of the site of (for irradiation) organs at risk, or if the localisation could only be performed with that method. The selected group of patients consisted of 120 patients for whom a reconstruction drawing in the transverse plane was made according to the treatment philosophy. In this group CT-assisted localisation was judged on 68 occasions superior to the conventional method. In a number of cases it was found that a ''standard'' change in a standard target volume, on the base of augmented anatomical knowledge, made the conventional method sufficient. The use of CT-scanner for treatment planning was estimated. For ca. 270/1000 new patients a CT-scan is helpful (diagnostic scan), for 140 of them the scan is necessary (planning scan). The quality of the anatomical information obtained with the T.A.T. does not yet fall within acceptable limits, but progress has been made. (Auth.)

  13. Solid phase extraction and trace monitoring of cadmium ions in environmental water and food samples based on modified magnetic nanoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Omidi, Fariborz [Department of Occupational Health Engineering, School of Public Health, Shahroud University of Medical Sciences, Shahroud (Iran, Islamic Republic of); Behbahani, Mohammad, E-mail: mohammadbehbahai89@yahoo.com [Department of Chemistry, Shahid Beheshti University, Evin, Tehran (Iran, Islamic Republic of); Kalate Bojdi, Majid [Faculty of Chemistry, Kharazmi (Tarbiat Moallem) University, Tehran (Iran, Islamic Republic of); Shahtaheri, Seyed Jamaleddin [Department of Occupational Health Engineering, School of Public Health and Institute for Environmental Research, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-12-01

    A new method has been developed for trace separation/preconcentration of cadmium ions using pyridine-functionalized magnetic nanoporous silica material (called Py-Fe{sub 3}O{sub 4}@MCM-41) as a new magnetic sorbent and their determination by flame atomic absorption spectrometry (FAAS). The Py-Fe{sub 3}O{sub 4}@MCM-41 sorbent was characterized by thermogravimetric analysis, differential thermal analysis, transmission electron microscopy, Fourier transform infrared spectrometry and X-ray diffraction. The modified Fe{sub 3}O{sub 4}@MCM-41 can be easily separated from an aqueous solution by applying an external magnetic field. Effects of pH, amount of functionalized Fe{sub 3}O{sub 4}@MCM-41, extraction time, type and quantity of eluent, desorption time, and interfering ions on the extraction efficiency were evaluated and optimized. Under the optimized conditions, the detection limit and relative standard deviation was 0.04 μg L{sup –1} and 2.9%, respectively and the maximum adsorption capacity of the synthesized sorbent for cadmium ions was 154 mg g{sup −1}. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, rice, onion, carrot, lettuce, parsley, basil, tap water, river water and seawater with satisfactory results. - Highlights: • The introducing of modified magnetic mesoporous silica as a novel magnetic sorbent. • Trace monitoring of cadmium ions. • The limit of detection (LOD) by the proposed solid phase extraction method was 0.04 ng mL{sup −1} for the cadmium ions. • High surface areas and magnetic characteristic of the sorbent. • Maximum adsorption capacity of the sorbent was 154 mg g{sup −1}.

  14. Synthesis and characterization of novel ion-imprinted guanyl-modified cellulose for selective extraction of copper ions from geological and municipality sample.

    Science.gov (United States)

    Kenawy, I M; Ismail, M A; Hafez, M A H; Hashem, M A

    2018-04-21

    The new ion-imprinted guanyl-modified cellulose (II.Gu-MC) was prepared for the separation and determination of Cu (II) ions in different real samples. Several techniques such as Fourier Transform Infrared (FT-IR), scanning electron microscope (SEM), thermal analysis, potentiograph and elemental analysis have been utilized for the characterization of II.Gu-MC. The adsorption behavior of the ion imprinted polymer (II.Gu-MC) was evaluated and compared to the non ion-imprinted polymer (NII.Gu-MC) at the optimum conditions. The selectivity and the adsorption capacity were greatly enhanced by using the ion-imprinted polymer, indicating its validation for the separation and determination of Cu 2+ ions in different matrices. The adsorption capacity by chelating fibers II.Gu-MC & NII.Gu-MC agreed with the second-order model, and the sorption-isotherm experiments revealed best agreement with Langmuir model. The adsorption capacity of II.Gu-MC and NII.Gu-MC were 115 and 55 mg·g -1 , respectively. The II.Gu-MC was successfully employed for the selective separation and determination of Cu(II) ions with high accuracy. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Optimum extracted H- and D- current densities from gas-pressure-limited high-power hydrogen/deuterium tandem ion sources

    International Nuclear Information System (INIS)

    Hiskes, J.R.

    1993-01-01

    The tandem hydrogen/deuterium ion source is modelled for the purpose of identifying the maximum current densities that can be extracted subject to the gas-pressure constraints proposed for contemporary beam-line systems. Optimum useful extracted current densities are found to be in the range of approximately 7 to 10 mA cm -2 . The sensitivity of these current densities is examined subject to uncertainties in the underlying atomic/molecular rate processes; A principal uncertainty remains the quantification of the molecular vibrational distribution following H 3 + wall collisions

  16. Portable Solid Phase Micro-Extraction Coupled with Ion Mobility Spectrometry System for On-Site Analysis of Chemical Warfare Agents and Simulants in Water Samples

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2014-11-01

    Full Text Available On-site analysis is an efficient approach to facilitate analysis at the location of the system under investigation as it can result in more accurate, more precise and quickly available analytical data. In our work, a novel self-made thermal desorption based interface was fabricated to couple solid-phase microextraction with ion mobility spectrometry for on-site water analysis. The portable interface can be connected with the front-end of an ion mobility spectrometer directly without other modifications. The analytical performance was evaluated via the extraction of chemical warfare agents and simulants in water samples. Several parameters including ionic strength and extraction time have been investigated in detail. The application of the developed method afforded satisfactory recoveries ranging from 72.9% to 114.4% when applied to the analysis of real water samples.

  17. Portable Solid Phase Micro-Extraction Coupled with Ion Mobility Spectrometry System for On-Site Analysis of Chemical Warfare Agents and Simulants in Water Samples

    Science.gov (United States)

    Yang, Liu; Han, Qiang; Cao, Shuya; Yang, Jie; Yang, Junchao; Ding, Mingyu

    2014-01-01

    On-site analysis is an efficient approach to facilitate analysis at the location of the system under investigation as it can result in more accurate, more precise and quickly available analytical data. In our work, a novel self-made thermal desorption based interface was fabricated to couple solid-phase microextraction with ion mobility spectrometry for on-site water analysis. The portable interface can be connected with the front-end of an ion mobility spectrometer directly without other modifications. The analytical performance was evaluated via the extraction of chemical warfare agents and simulants in water samples. Several parameters including ionic strength and extraction time have been investigated in detail. The application of the developed method afforded satisfactory recoveries ranging from 72.9% to 114.4% when applied to the analysis of real water samples. PMID:25384006

  18. Kaon transverse charge density from space- and timelike data

    Science.gov (United States)

    Mecholsky, N. A.; Meija-Ott, J.; Carmignotto, M.; Horn, T.; Miller, G. A.; Pegg, I. L.

    2017-12-01

    We used the world data on the kaon form factor to extract the transverse kaon charge density using a dispersion integral of the imaginary part of the kaon form factor in the timelike region. Our analysis includes recent data from e+e- annihiliation measurements extending the kinematic reach of the data into the region of high momentum transfers conjugate to the region of short transverse distances. To calculate the transverse density we created a superset of both timelike and spacelike data and developed an empirical parameterization of the kaon form factor. The spacelike set includes two new data points we extracted from existing cross section data. We estimate the uncertainty on the resulting transverse density to be 5% at b =0.025 fm and significantly better at large distances. New kaon data planned with the 12 GeV Jefferson Lab may have a significant impact on the charge density at distances of b <0.1 fm.

  19. Development and application of ion beam diagnostics

    International Nuclear Information System (INIS)

    Pfister, Jochen

    2010-01-01

    At GSI - Helmholtz Centre for Heavy Ion Research in Darmstadt/Germany the HITRAP project is in the commissioning phase. This world-wide unique facility consists of a linear decelerator for heavy, highly charged ions including atomic physics precision experiments. During commissioning of the cavities, transverse emittances were measured using the single-shot pepperpot method as well as the multi-gradient method. The extraction emittance of the experimental storage ring (ESR) was determined. Furthermore, the phase space distribution of an decelerated beam at an intermediate energy of 500keV/u was measured behind the IH-structure. New algorithms have been integrated into the analysis of digital images. The longitudinal bunch structure measurements of the ion beam at the entry point into the decelerator and the operation of the Double-drift Buncher is shown. The design, development and the first commissioning of a new single-shot pepperpot emittance meter for very low beam currents and beam energies in the order of some hundred nA is described, making it possible to measure the beam behind the deceleration cavities. In addition, transverse beam dynamics calculations were performed, which supported the hands-on commissioning of the accelerator. It is described how the entire beam line from the ESR to the radio-frequency quadrupole can be optimized using the new routine for transverse effects of the bunching and deceleration, which was successfully integrated into the software COSY Infinity. (orig.)

  20. Dynamical observation of lithium insertion/extraction reaction during charge-discharge processes in Li-ion batteries by in situ spatially resolved electron energy-loss spectroscopy.

    Science.gov (United States)

    Shimoyamada, Atsushi; Yamamoto, Kazuo; Yoshida, Ryuji; Kato, Takehisa; Iriyama, Yasutoshi; Hirayama, Tsukasa

    2015-12-01

    All-solid-state Li-ion batteries (LIBs) with solid electrolytes are expected to be the next generation devices to overcome serious issues facing conventional LIBs with liquid electrolytes. However, the large Li-ion transfer resistance at the electrode/solid-electrolyte interfaces causes low power density and prevents practical use. In-situ-formed negative electrodes prepared by decomposing the solid electrolyte Li(1+x+3z)Alx(Ti,Ge)(2-x)Si(3z)P(3-z)O12 (LASGTP) with an excess Li-ion insertion reaction are effective electrodes providing low Li-ion transfer resistance at the interfaces. Prior to our work, however, it had still been unclear how the negative electrodes were formed in the parent solid electrolytes. Here, we succeeded in dynamically visualizing the formation by in situ spatially resolved electron energy-loss spectroscopy in a transmission electron microscope mode (SR-TEM-EELS). The Li-ions were gradually inserted into the solid electrolyte region around 400 nm from the negative current-collector/solid-electrolyte interface in the charge process. Some of the ions were then extracted in the discharge process, and the rest were diffused such that the distribution was almost flat, resulting in the negative electrodes. The redox reaction of Ti(4+)/Ti(3+) in the solid electrolyte was also observed in situ during the Li insertion/extraction processes. The in situ SR-TEM-EELS revealed the mechanism of the electrochemical reaction in solid-state batteries. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Laser ion source with long pulse width for RHIC-EBIS

    International Nuclear Information System (INIS)

    Kondo, K.; Kanesue, T.; Okamura, M.

    2011-01-01

    The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

  2. Transversity quark distributions in a covariant quark-diquark model

    Energy Technology Data Exchange (ETDEWEB)

    Cloet, I.C. [Physics Division, Argonne National Laboratory, Argonne, IL 60439-4843 (United States)], E-mail: icloet@anl.gov; Bentz, W. [Department of Physics, School of Science, Tokai University, Hiratsuka-shi, Kanagawa 259-1292 (Japan)], E-mail: bentz@keyaki.cc.u-tokai.ac.jp; Thomas, A.W. [Jefferson Lab, 12000 Jefferson Avenue, Newport News, VA 23606 (United States); College of William and Mary, Williamsburg, VA 23187 (United States)], E-mail: awthomas@jlab.org

    2008-01-17

    Transversity quark light-cone momentum distributions are calculated for the nucleon. We utilize a modified Nambu-Jona-Lasinio model in which confinement is simulated by eliminating unphysical thresholds for nucleon decay into quarks. The nucleon bound state is obtained by solving the relativistic Faddeev equation in the quark-diquark approximation, where both scalar and axial-vector diquark channels are included. Particular attention is paid to comparing our results with the recent experimental extraction of the transversity distributions by Anselmino et al. We also compare our transversity results with earlier spin-independent and helicity quark distributions calculated in the same approach.

  3. Transverse spin and transverse momentum in scattering of plane waves

    OpenAIRE

    Saha, Sudipta; Singh, Ankit K.; Ray, Subir K.; Banerjee, Ayan; Gupta, Subhasish Dutta; Ghosh, Nirmalya

    2016-01-01

    We study the near field to the far field evolution of spin angular momentum (SAM) density and the Poynting vector of the scattered waves from spherical scatterers. The results show that at the near field, the SAM density and the Poynting vector are dominated by their transverse components. While the former (transverse SAM) is independent of the helicity of the incident circular polarization state, the latter (transverse Poynting vector) depends upon the polarization state. It is further demon...

  4. Comparison of dialysis and solid-phase extraction for isolation and concentration of dissolved organic matter prior to Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tfaily, Malak M.; Cooper, William T. [Florida State University, Department of Chemistry and Biochemistry, Tallahassee, FL (United States); Hodgkins, Suzanne; Chanton, Jeffrey P. [Florida State University, Department of Earth, Ocean and Atmospheric Science, Tallahassee, FL (United States); Podgorski, David C. [Florida State University, Department of Chemistry and Biochemistry, Tallahassee, FL (United States); Florida State University, National High Magnetic Field Laboratory, Tallahassee, FL (United States)

    2012-08-15

    We compare two methods, solid-phase extraction (SPE) and dialysis, commonly used for extraction and concentration of dissolved organic matter (DOM) prior to molecular characterization by electrospray ionization (ESI) and ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry. Spectra of DOM samples from Minnesota and Sweden peatlands that were extracted with styrene divinyl benzene polymer SPE sorbents included ions with formulas that had higher oxygen to carbon (O/C) ratios than spectra of DOM from the same samples after de-salting by dialysis. The SPE method was not very effective in extracting several major classes of DOM compounds that had high ESI efficiencies, including carboxylic acids and organo-sulfur compounds, and that out-competed other less-functionalized compounds (e.g., carbohydrates) for charge in the ESI source. The large abundance of carboxylic acids in the dialysisextracted DOM, likely the result of in situ microbial production, makes it difficult to see other (mainly hydrophilic) compounds with high O/C ratios. Our results indicate that, while dialysis is generally preferable for the isolation of DOM, for samples with high microbial inputs, the use of both isolation methods is recommended for a more accurate molecular representation. (orig.)

  5. Extraction of inhibitor-free metagenomic DNA from polluted sediments, compatible with molecular diversity analysis using adsorption and ion-exchange treatments.

    Science.gov (United States)

    Desai, Chirayu; Madamwar, Datta

    2007-03-01

    PCR inhibitor-free metagenomic DNA of high quality and high yield was extracted from highly polluted sediments using a simple remediation strategy of adsorption and ion-exchange chromatography. Extraction procedure was optimized with series of steps, which involved gentle mechanical lysis, treatment with powdered activated charcoal (PAC) and ion-exchange chromatography with amberlite resin. Quality of the extracted DNA for molecular diversity analysis was tested by amplifying bacterial 16S rDNA (16S rRNA gene) with eubacterial specific universal primers (8f and 1492r), cloning of the amplified 16S rDNA and ARDRA (amplified rDNA restriction analysis) of the 16S rDNA clones. The presence of discrete differences in ARDRA banding profiles provided evidence for expediency of the DNA extraction protocol in molecular diversity studies. A comparison of the optimized protocol with commercial Ultraclean Soil DNA isolation kit suggested that method described in this report would be more efficient in removing metallic and organic inhibitors, from polluted sediment samples.

  6. Cloud Point Extraction and Determination of Silver Ion in Real Sample using Bis((1H-benzo[d ]imidazol-2ylmethylsulfane

    Directory of Open Access Journals (Sweden)

    Farshid Ahmadi

    2011-01-01

    Full Text Available Bis((1H-benzo[d]imidazol-2ylmethylsulfane (BHIS was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of silver. The method is based on the extraction of silver at pH 8.0 by using non-ionic surfactant T-X114 and bis((1H-benzo[d]imidazol-2ylmethylsulfane as a chelating agent. The adopted concentrations for BHIS, Triton X-114 and HNO3, bath temperature, centrifuge rate and time were optimized. Detection limits (3SDb/m of 1.7 along with enrichment factor of 39 for silver ion was achieved. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method was successfully applied to the ultra-trace determination of silver in real samples.

  7. Fabrication of a novel hydrophobic/ion-exchange mixed-mode adsorbent for the dispersive solid-phase extraction of chlorophenols from environmental water samples.

    Science.gov (United States)

    Gao, Li; Wei, Yinmao

    2016-08-01

    A novel mixed-mode adsorbent was prepared by functionalizing silica with tris(2-aminoethyl)amine and 3-phenoxybenzaldehyde as the main mixed-mode scaffold due to the presence of the plentiful amino groups and benzene rings in their molecules. The adsorption mechanism was probed with acidic, natural and basic compounds, and the mixed hydrophobic and ion-exchange interactions were found to be responsible for the adsorption of analytes. The suitability of dispersive solid-phase extraction was demonstrated in the determination of chlorophenols in environmental water. Several parameters, including sample pH, desorption solvent, ionic strength, adsorbent dose, and extraction time were optimized. Under the optimal extraction conditions, the proposed dispersive solid-phase extraction coupled with high-performance liquid chromatography showed good linearity range and acceptable limits of detection (0.22∽0.54 ng/mL) for five chlorophenols. Notably, the higher extraction recoveries (88.7∽109.7%) for five chlorophenols were obtained with smaller adsorbent dose (10 mg) and shorter extraction time (15 min) compared with the reported methods. The proposed method might be potentially applied in the determination of trace chlorophenols in real water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Sodium dodecyl sulfate coated γ-alumina support modified by a new Schiff base for solid phase extraction and flame-AAS determination of lead and copper ions

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2013-01-01

    Full Text Available A simple and fast approach for solid phase extraction is herein described, and used to determine trace amounts of Pb2+ and Cu2+ metal ions. The solid phase support is sodium dodecyl sulfate (SDS-coated γ-alumina modified with bis(2-hydroxy acetophenone-1,6-hexanediimine (BHAH ligand. The adsorbed ions were stripped from the solid phase by 6 mL of 4 M nitric acid as eluent. The eluting solution was analyzed by flame atomic absorption spectrometry (FAAS. The sorption recovery of metal ions was investigated with regard to the effects of pH, amount of ligand, γ-alumina and surfactant and the amount and type of eluent. Complexation of BHAH with Pb2+ or Cu2+ ions was examined via spectrophotometry using the HypSpec program. The detection limit for Cu2+ was 7.9 µg L-1 with a relative standard deviation of 1.67%, while that for Pb2+ was 6.4 µg L-1 with a relative standard deviation of 1.64%. A preconcentration factor of 100 was achieved for these ions. The method was successfully applied to determine analyte concentrations in samples of liver, parsley, cabbage, and water.

  9. Signals for transversity and transverse-momentum-dependent quark distribution functions studied at the HERMES experiment

    Energy Technology Data Exchange (ETDEWEB)

    Diefenthaler, Markus

    2010-08-15

    Intention of the present thesis was the study of transverse-momentum dependent quark distribution functions. In the focus stood the Fourier analysis of azimutal single-spin asymmetries of pions and charged kaons performed within the HERMES experiment. These asymmetries were reconstructed from deep-inelastic scattering events on a transversely polarized proton target and decomposed in Fourier components. In the framework of quantum chromodynamics such components can be interpreted as folding of quark distribution and fragmentation functions. By the analysis of the transverse-momentum dependent quark distribution functions the study of spin-orbit correlations in the internal of the nucleon was made possible. By this conclusions on the orbital angular momentum of the quarks can be drawn. The extracted Fourier components extend the hitherto available informations on the transverse-momentum dependent quark distribution functions remarkably. The presented Fourier analysis made not only a detection of the Collins and Sivers effects possible, but beyond the extraction of the signals of the pretzelosity and worm-gear distributions. The so obtained results will conclusively contribute to the understanding of future measurements in this field and furthermore make possible a test of fundamental predictions of quantum chromodynamics.

  10. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples

    Energy Technology Data Exchange (ETDEWEB)

    Rajabi, Maryam, E-mail: mrajabi@semnan.ac.ir; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-03-08

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}, and Ni{sup 2+} prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2–70, 6–360, 7–725, 7–370, and 8–450 ng mL{sup −1} for the Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}and Ni{sup 2+} ions, respectively, with the correlation of determinations (R{sup 2}s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd{sup 2+}, Cr{sup 6+}, Pb{sup 2+}, Co{sup 2+}, and Ni{sup 2+} ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid

  11. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples

    International Nuclear Information System (INIS)

    Rajabi, Maryam; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-01-01

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2–70, 6–360, 7–725, 7–370, and 8–450 ng mL −1 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ and Ni 2+ ions, respectively, with the correlation of determinations (R 2 s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid and tap water samples. - Highlights: • A novel centrifugeless dispersive

  12. Characterization and monitoring of transverse beam tails

    International Nuclear Information System (INIS)

    Seeman, J.T.; Decker, F.J.; Hsu, I.; Young, C.

    1991-05-01

    Low emittance electron beams accelerated to high energy in a linac experience transverse effects (wakefield, filamentation, optics) which produce non-Gaussian projected transverse beam distributions. Characterizations of the beam shapes are difficult because the shapes are asymmetric and change with betatron phase. In this note several methods to describe beam distributions are discussed including an accelerator physics model of these tails. The uses of these characterizations in monitoring the beam emittances in the SLC are described in this paper. First, two dimensional distributions from profile monitor screens are reviewed showing correlated tails. Second, a fitting technique for non-Gaussian one dimensional distributions is used to extract the core from the tail areas. Finally, a model for tail propagation in the linac is given. 3 refs., 6 figs

  13. Transverse momentum distributions and nuclear effects

    Directory of Open Access Journals (Sweden)

    Pace Emanuele

    2015-01-01

    Full Text Available A distorted spin-dependent spectral function for 3He is considered to take care of the final state interaction in the extraction of the quark transverse-momentum distributions in the neutron from semi-inclusive deep inelastic electron scattering off polarized 3He at finite momentum transfers. The generalization of the analysis in a Poincaré covariant framework within the light-front dynamics is outlined. The definition of the light-front spin-dependent spectral function for a J=1/2 system, as the nucleon, allows us to show that within the light-front dynamics and in the valence approximation only three of the six leading twist T-even transverse-momentum distributions are independent.

  14. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  15. What do we learn from transverse energy distributions?

    International Nuclear Information System (INIS)

    Baym, G.; Friedman, G.; Heiselberg, H.

    1990-01-01

    Transverse energy measurements provide a wealth of information on the physics of ultrarelativistic heavy-ion collisions. To begin with they tell one the degree to which the colliding nuclei transfer energy and stop each other. With information about the space-time dynamics of the collisions, transverse energy data enables one to estimate the evolving energy density in the collision volume, a quantity needed to assess the likelihood of quark-gluon plasma formation. Furthermore, since the transverse energy distribution is to a large extent determined by the geometry of the collision, transverse energy is a useful indicator of centrality of collisions. It also provides considerable evidence for the rescattering of secondaries in the medium. Finally, fluctuations in the tails of the transverse energy distributions are an important probe of the independence of or possible coherence among the nucleon-nucleon subcollisions that constitute the first stage of heavy-ion collisions. Since the experimental talks in this workshop have done a rather complete job of presenting the transverse energy data from both BNL and CERN, the focus, as the authors discuss these topics in turn, will be on the theoretical interpretation of the data

  16. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  17. Transverse spin effects

    International Nuclear Information System (INIS)

    Ratcliffe, P.G.

    1993-01-01

    A discussion is presented of the role that transverse spin physics can play in providing information on the bound state dynamics in hadronic physics. Care is taken to distinguish between single- and double-spin measurements, each being discussed separately. In the case of single-spin effects it is stressed that as yet no satisfactory explanation has been provided within the framework if perturbative QCD which in fact generally predicts negligible effects. In order to clarify the situation experimental data at yet higher p T are necessary and semi-leptonic data could shed some light on the underlying scattering mechanisms. As regards double-spin correlations, the theoretical picture (although clouded by some ill-informed, often erroneous statements and even recent papers) is rather well understood and what is dearly missing is the experimental study of, for example, g 2 in deep-inelastic scattering. (author). 31 refs

  18. Assessment of the ion-trap mass spectrometer for routine qualitative and quantitative analysis of drugs of abuse extracted from urine.

    Science.gov (United States)

    Vorce, S P; Sklerov, J H; Kalasinsky, K S

    2000-10-01

    The ion-trap mass spectrometer (MS) has been available as a detector for gas chromatography (GC) for nearly two decades. However, it still occupies a minor role in forensic toxicology drug-testing laboratories. Quadrupole MS instruments make up the majority of GC detectors used in drug confirmation. This work addresses the use of these two MS detectors, comparing the ion ratio precision and quantitative accuracy for the analysis of different classes of abused drugs extracted from urine. Urine specimens were prepared at five concentrations each for amphetamine (AMP), methamphetamine (METH), benzoylecgonine (BZE), delta9-carboxy-tetrahydrocannabinol (delta9-THCCOOH), phencyclidine (PCP), morphine (MOR), codeine (COD), and 6-acetylmorphine (6-AM). Concentration ranges for AMP, METH, BZE, delta9-THCCOOH, PCP, MOR, COD, and 6-AM were 50-2500, 50-5000, 15-800, 1.5-65, 1-250, 500-32000, 250-21000, and 1.5-118 ng/mL, respectively. Sample extracts were injected into a GC-quadrupole MS operating in selected ion monitoring (SIM) mode and a GC-ion-trap MS operating in either selected ion storage (SIS) or full scan (FS) mode. Precision was assessed by the evaluation of five ion ratios for n = 15 injections at each concentration using a single-point calibration. Precision measurements for SIM ion ratios provided coefficients of variation (CV) between 2.6 and 9.8% for all drugs. By comparison, the SIS and FS data yielded CV ranges of 4.0-12.8% and 4.0-11.2%, respectively. The total ion ratio failure rates were 0.2% (SIM), 0.7% (SIS), and 1.2% (FS) for the eight drugs analyzed. Overall, the SIS mode produced stable, comparable mean ratios over the concentration ranges examined, but had greater variance within batch runs. Examination of postmortem and quality-control samples produced forensically accurate quantitation by SIS when compared to SIM. Furthermore, sensitivity of FS was equivalent to SIM for all compounds examined except for 6-AM.

  19. A novel magnetic metal organic framework nanocomposite for extraction and preconcentration of heavy metal ions, and its optimization via experimental design methodology

    International Nuclear Information System (INIS)

    Taghizadeh, Mohsen; Asgharinezhad, Ali Akbar; Pooladi, Mohsen; Barzin, Mahnaz; Abbaszadeh, Abolfazl; Tadjarodi, Azadeh

    2013-01-01

    We describe a novel magnetic metal-organic framework (MOF) prepared from dithizone-modified Fe 3 O 4 nanoparticles and a copper-(benzene-1,3,5-tricarboxylate) MOF and its use in the preconcentration of Cd(II), Pb(II), Ni(II), and Zn(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, amount of the magnetic sorbent, and pH value) were selected as the main factors affecting adsorption, while four variables (type, volume and concentration of the eluent; desorption time) were selected for desorption in the optimization study. Following preconcentration and elution, the ions were quantified by FAAS. The limits of detection are 0.12, 0.39, 0.98, and 1.2 ng mL −1 for Cd(II), Zn(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations were −1 of Cd(II), Zn(II), Ni(II), and Pb(II) ions. The adsorption capacities (in mg g −1 ) of this new MOF are 188 for Cd(II), 104 for Pb(II), 98 Ni(II), and 206 for Zn(II). The magnetic MOF nanocomposite has a higher capacity than the Fe 3 O 4 /dithizone conjugate. This magnetic MOF nanocomposite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples. (author)

  20. Jet axes and universal transverse-momentum- dependent fragmentation

    International Nuclear Information System (INIS)

    Neill, Duff; Scimemi, Ignazio; Waalewijn, Wouter J.

    2017-01-01

    We study the transverse momentum spectrum of hadrons in jets. By measuring the transverse momentum with respect to a judiciously chosen axis, we find that this observable is insensitive to (the recoil of) soft radiation. Furthermore, for small transverse momenta we show that the effects of the jet boundary factorize, leading to a new transverse-momentum-dependent (TMD) fragmentation function. In contrast to the usual TMD fragmentation functions, it does not involve rapidity divergences and is universal in the sense that it is independent of the type of process and number of jets. These results directly apply to sub-jets instead of hadrons. We discuss potential applications, which include studying nuclear modification effects in heavy-ion collisions and identifying boosted heavy resonances.

  1. The emittance of high current heavy ion beams

    International Nuclear Information System (INIS)

    White, N.R.; Devaney, A.S.

    1989-01-01

    Ion implantation is the main application for high current heavy ion beams. Transfer ratio is defined as the ratio of the total ion current leaving the ion source to the current delivered to the endstation. This ratio is monitored and logged and its importance is explained. It is also affected by other factors, such as the isotopic and molecular composition of the total ion beam. The transfer ratio reveals the fraction of ions which are intercepted by parts of the beamline system. The effects of these ions are discussed in two categories: processing purity and reliability. In discussing the emittance of ribbon beams, the two orthogonal planes are usually considered separately. Longitudinal emittance is determined by slot length and by plasma ion temperature. It has already been revealed that the longitudinal divergence of the beams from BF3 is perhaps double that of the beam from arsenic vapour or argon, at the same total perveance from the ion source. This poses the question: why is the ion temperature higher for BF3 than for As or Ar? The transverse emittance is in practical terms dominated by the divergence. It is the most fruitful area for improvement in most real-world systems. There is an intrinsic divergence arising from initial ion energies within the plasma, and there is emittance growth that can occur as a result of aberration in the beam extraction optics. (N.K.)

  2. A novel lead imprinted polymer as the selective solid phase for extraction and trace detection of lead ions by flame atomic absorption spectrophotometry: Synthesis, characterization and analytical application

    Directory of Open Access Journals (Sweden)

    Homeira Ebrahimzadeh

    2017-05-01

    Full Text Available A novel ion imprinted polymer as the selective solid phase combined with flame atomic absorption spectrometry (FAAS was applied for preconcentration and determination of lead in real samples. In the first step, Pb(II-IIP was synthesized by copolymerization of 2-vinyl pyridine as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, 2,2-azobisisobutyronitrile as the initiator that imprinted with Pb(II as the template ion, 2-amino pyridine as the ligand. Subsequently, the imprinted Pb(II was completely removed by leaching the dried and powdered imprinted polymer with HCl (2 mol L−1. This polymer was characterized by Fourier Transform Infrared (FT-IR spectrometer. The effect of different variables on the extraction efficiency such as type and volume of eluent for extraction, solution’s pH for adsorption, sorption and desorption times was evaluated. Under the optimum conditions: type of eluent, HCl (2 mol L−1; volume of eluent, 5 mL; solution’s pH for sorption, 5; sorption time, 90 min; desorption time, 125 min and breakthrough volume of 750 mL were obtained. Preconcentration factor of the method was about 150. The limit of detection was obtained 0.75 μg L−1 and a dynamic linear range (DLR of 3–150 μg L−1 was found. The maximum sorption retention capacity of Pb(II ions on the imprinted polymer was 85.6 mg g−1. The prepared ion-imprinted polymer particles have an increased selectivity toward Pb(II ions over a range of competing metal ions with the same charge and similar ionic radius. Performance of the present method was evaluated for extraction and determination of Pb(II in water samples at microgram per liter concentration and satisfactory results were obtained (RSD = 2.7%.

  3. Quantitative determination of sotolon, maltol and free furaneol in wine by solid-phase extraction and gas chromatography-ion-trap mass spectrometry.

    Science.gov (United States)

    Ferreira, Vicente; Jarauta, Idoia; López, Ricardo; Cacho, Juan

    2003-08-22

    A method for the analytical determination of sotolon [4,5-dimethyl-3-hydroxy-2(5H)-furanone], maltol [3-hydroxy-2-methyl-4H-pyran-4-one] and free furaneol [2,5-dimethyl-4-hydroxy-3(2H)-furanone] in wine has been developed. The analytes are extracted from 50 ml of wine in a solid-phase extraction cartridge filled with 800 mg of LiChrolut EN resins. Interferences are removed with 15 ml of a pentane-dichloromethane (20:1) solution, and analytes are recovered with 6 ml of dichloromethane. The extract is concentrated up to 0.1 ml and analyzed by GC-ion trap MS. Maltol and sotolon were determined by selected ion storage of ions in the m/z ranges 120-153 and 79-95, using the ions m/z 126 and 83 for quantitation, respectively. Furaneol was determined by non-resonant fragmentation of the m/z 128 mother ion and subsequent analysis of the m/z 81 ion. The detection limits of the method are in all cases between 0.5 and 1 microg l(-1), well below the olfactory thresholds of the compounds. The precision of the method is in the 4-5% range for levels in wine around 20 microg l(-1). Linearity holds at least up to 400 microg l(-1), and is satisfactory in all cases. The recoveries of maltol and sotolon are constant (70 and 64%, respectively) and do not depend on the type of wine. On the contrary, in the case of furaneol, red wines show constant and high recoveries (97%), while the recoveries on white wines range between 30 and 80%. Different experiments showed that this behavior is probably due to the existence of complexes formed between furaneol and sulphur dioxide or catechols. Sensory experiments confirmed that the complexed forms found in white wines are not perceived by orthonasal olfaction, and that the furaneol determined by the method can be considered as the free and odor-active fraction.

  4. Online Capacity Estimation of Lithium-Ion Batteries Based on Novel Feature Extraction and Adaptive Multi-Kernel Relevance Vector Machine

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2015-11-01

    Full Text Available Prognostics is necessary to ensure the reliability and safety of lithium-ion batteries for hybrid electric vehicles or satellites. This process can be achieved by capacity estimation, which is a direct fading indicator for assessing the state of health of a battery. However, the capacity of a lithium-ion battery onboard is difficult to monitor. This paper presents a data-driven approach for online capacity estimation. First, six novel features are extracted from cyclic charge/discharge cycles and used as indirect health indicators. An adaptive multi-kernel relevance machine (MKRVM based on accelerated particle swarm optimization algorithm is used to determine the optimal parameters of MKRVM and characterize the relationship between extracted features and battery capacity. The overall estimation process comprises offline and online stages. A supervised learning step in the offline stage is established for model verification to ensure the generalizability of MKRVM for online application. Cross-validation is further conducted to validate the performance of the proposed model. Experiment and comparison results show the effectiveness, accuracy, efficiency, and robustness of the proposed approach for online capacity estimation of lithium-ion batteries.

  5. Dissolvable layered double hydroxide as an efficient nanosorbent for centrifugeless air-agitated dispersive solid-phase extraction of potentially toxic metal ions from bio-fluid samples.

    Science.gov (United States)

    Rajabi, Maryam; Arghavani-Beydokhti, Somayeh; Barfi, Behruz; Asghari, Alireza

    2017-03-08

    In the present work, a novel nanosorbent namely layered double hydroxides with 4-amino-5-hydroxyl-2,7-naphthalendisulfonic acid monosodium salt interlayer anion (Mg-Al-AHNDA-LDH) was synthesized and applied as a dissolvable nanosorbent in a centrifugeless ultrasound-enhanced air-agitated dispersive solid-phase extraction (USE-AA-D-SPE) method. This method was used for the separation and preconcentration of some metal ions including Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ prior to their determination using the micro-sampling flame atomic absorption spectrometry (MS-FAAS) technique. The most interesting aspect of this nanosorbent is its immediate dissolvability at pH values lower than 4. This capability drastically eliminates the elution step, leading to a great improvement in the extraction efficiency and a decrease in the extraction time. Also in this method, the use of a syringe nanofilter eliminates the need for the centrifugation step, which is time-consuming and essentially causes the analysis to be off-line. Several effective parameters governing the extraction efficiency including the sample solution pH, amount of nanosorbent, eluent condition, number of air-agitation cycles, and sonication time were investigated and optimized. Under the optimized conditions, the good linear dynamic ranges of 2-70, 6-360, 7-725, 7-370, and 8-450 ng mL -1 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ and Ni 2+ ions, respectively, with the correlation of determinations (R 2 s) higher than 0.997 were obtained. The limits of detection (LODs) were found to be 0.6, 1.7, 2.0, 2.1, and 2.4 for the Cd 2+ , Cr 6+ , Pb 2+ , Co 2+ , and Ni 2+ ions, respectively. The intra-day and inter-day precisions (percent relative standard deviations (%RSDs) (n = 5)) were below 7.8%. The proposed method was also successfully applied for the extraction and determination of the target ions in different biological fluid and tap water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation

    NARCIS (Netherlands)

    Peters, S.; Kaal, E.; Horsting, I.; Janssen, H.-G.

    2012-01-01

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing ‘Micro-extraction in packed sorbent’ (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve

  7. Economical synthesis of silver nanoparticles using leaf extract of Acalypha hispida and its application in the detection of Mn(II ions

    Directory of Open Access Journals (Sweden)

    R. Sithara

    2017-11-01

    Full Text Available This study was focused on the synthesis of silver nanoparticles using Acalypha hispida leaf extract and the characterization of the particles using UV–Vis spectroscopy, XRD, FT-IR, and TEM. The results showed the formation of silver nanoparticles, crystalline in nature, with an average size of 20–50 nm. The leaf extract components were analyzed with GC–MS and exhibited a high content of Phytol (40.52%, n-Hexadecanoic acid (9.67%, 1,2,3-Benzenetriol (7.04%, α-d-Mannofuranoside methyl (6.22%, and d-Allose (4.45%. The optimization and statistical investigation of reaction parameters were studied and maximum yield with suitable properties of silver nanoparticles was obtained at leaf extract volume (0.5 mL, the concentration of silver nitrate (1.75 mM, and reaction temperature (50 °C. The method of detecting Mn2+ ions using the colloidal silver nanoparticles was discussed. The minimum and maximum detection limit were found to be 50 and 200 µM of Mn(II ions, respectively. Thus, the obtained results encourage the use of economical synthesis of silver nanoparticles in the development of nanosensors to detect the pollutants present in industrial effluents.

  8. Coupled transverse motion

    International Nuclear Information System (INIS)

    Teng, L.C.

    1989-01-01

    The magnetic field in an accelerator or a storage ring is usually so designed that the horizontal (x) and the vertical (y) motions of an ion are uncoupled. However, because of imperfections in construction and alignment, some small coupling is unavoidable. In this lecture, we discuss in a general way what is known about the behaviors of coupled motions in two degrees-of-freedom. 11 refs., 6 figs

  9. Extraction process

    International Nuclear Information System (INIS)

    Rendall, J.S.; Cahalan, M.J.

    1979-01-01

    A process is described for extracting at least two desired constituents from a mineral, using a liquid reagent which produces the constituents, or compounds thereof, in separable form and independently extracting those constituents, or compounds. The process is especially valuable for the extraction of phosphoric acid and metal values from acidulated phosphate rock, the slurry being contacted with selective extractants for phosphoric acid and metal (e.g. uranium) values. In an example, uranium values are oxidized to uranyl form and extracted using an ion exchange resin. (U.K.)

  10. Flame Atomic Absorption Spectrometric Determination of Ultra Traces of Thallium(I) ion after Solid Phase Extraction by Octadecyl Silica Membrane Disk Modified by a New Schiff Base

    International Nuclear Information System (INIS)

    Mashhadizadeh, Mohammad Hossein; Moatafavi, Ali; Allah-Abadi, Hossein; Zadmehr, Mohammad Reza

    2004-01-01

    A simple and reliable method has been developed to selectively separate and concentrate trace amounts of thallium ion from real samples for the subsequent measurement by flame atomic absorption spectrometry (FAAS). Thallium ions are absorbed quantitatively during passage of aqueous real samples through an octadecyl bonded silica membrane disk modified by 4-(4-Chloro-phenylazo)-2-[(4-hydroxy-phenylamino)- methyl]-phenol. The retained Tl + ions are then stripped from the disk quantitatively with a minimal amount of thiosulfate solution as eluent. The proposed method permitted large enrichment factors of about 130 and higher. The relative standard deviation for ten replicate extraction of thallium from 1 L samples containing 5 μg thallium is 1.2%. The break through volume for 5 μg thallium is 1000 mL. The limit of detection of the proposed method is 11.2 ng of Tl + per 1000 mL. The effects of various cationic interferences on the recovery of thallium in binary mixtures were studied. The method was applied to the recovery of Tl + ions from natural water and human hair samples

  11. Extraction of Dysprosium Ions with DTPA Functionalized Superparamagnetic Nanoparticles Probed by Energy Dispersive X-ray Fluorescence and TEM/High-Angle Annular Dark Field Imaging.

    Science.gov (United States)

    Melo, Fernando Menegatti de; Almeida, Sabrina da Nobrega; Uezu, Noemi Saori; Ramirez, Carlos Alberto Ospina; Santos, Antonio Domingues Dos; Toma, Henrique Eisi

    2018-06-01

    The extraction of dysprosium (Dy3+) ions from aqueous solution was carried out successfully, using magnetite (Fe3O4) nanoparticles functionalized with diethylenetriaminepentaacetic acid (MagNP@DTPA). The process was monitored by energy dispersive X-ray fluorescence spectroscopy, as a function of concentration, proceeding according to a Langmuir isotherm with an equilibrium constant of 2.57 × 10-3 g(MagNP) L-1 and a saturation limit of 63.2 mgDy/gMagNP. The presence of paramagnetic Dy3+ ions attached to the superparamagnetic nanoparticles led to an overall decrease of magnetization. By imaging the nanoparticles surface using scanning transmission electron microscopy equipped with high resolution elemental analysis, it was possible to probe the binding of the Dy3+ ions to DTPA, and to show their distribution in a region of negative magnetic field gradients. This finding is coherent with the observed decrease of magnetization, associated with the antiferromagnetic coupling between the lanthanide ions and the Fe3O4 core.

  12. Modified Extraction-Free Ion-Pair Methods for the Determination of Flunarizine Dihydrochloride in Bulk Drug, Tablets, and Human Urine

    Science.gov (United States)

    Prashanth, K. N.; Basavaiah, K.

    2018-01-01

    Two simple and sensitive extraction-free spectrophotometric methods are described for the determination of flunarizine dihydrochloride. The methods are based on the ion-pair complex formation between the nitrogenous compound flunarizine (FNZ), converted from flunarizine dihydrochloride (FNH), and the acidic dye phenol red (PR), in which experimental variables were circumvented. The first method (method A) is based on the formation of a yellow-colored ion-pair complex (1:1 drug:dye) between FNZ and PR in chloroform, which is measured at 415 nm. In the second method (method B), the formed drug-dye ion-pair complex is treated with ethanolic potassium hydroxide in an ethanolic medium, and the resulting base form of the dye is measured at 580 nm. The stoichiometry of the formed ion-pair complex between the drug and dye (1:1) is determined by Job's continuous variations method, and the stability constant of the complex is also calculated. These methods quantify FNZ over the concentration ranges 5.0-70.0 in method A and 0.5-7.0 μg/mL in method B. The calculated molar absorptivities are 6.17 × 103 and 5.5 × 104 L/mol·cm-1 for method A and method B, respectively, with corresponding Sandell sensitivity values of 0.0655 and 0.0074 μg/cm2. The methods are applied to the determination of FNZ in pure drug and human urine.

  13. Chemical Modification of Activated Carbon and Its Application for Solid Phase Extraction of Copper(II and Iron(III Ions

    Directory of Open Access Journals (Sweden)

    M. Ghaedi

    2014-06-01

    Full Text Available Powder activated carbon surface (AC was grinded and modified and altered procedure thorough a facile and easy chemical reaction to appearance of 2-((3silylpropylimino1-methyl phenol (AC- (SPIMP. Subsequently, this novel sorbent efficiently applied for the extraction and preconcentration of some metal ions from real samples. Preliminary the influences of variables such as pH, amounts of reagents and porous AC, eluting solution conditions (type and concentrations, sample volume and influence of interference of many ions on the analytes recoveries was studied and optimized. This new sorbents property including pore size, pore volume and surface properties was evaluated and monitored by BET, while structure and homogeneously of sorbent was identified by SEM. The surface modification was traced by FT-IR as powerful and strong identification techniques. The proposed sorbent has high surface area(>1317.1346 m2 g-1 and small pore size(

  14. Classical Weyl transverse gravity

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Ichiro [University of the Ryukyus, Department of Physics, Faculty of Science, Nishihara, Okinawa (Japan)

    2017-05-15

    We study various classical aspects of the Weyl transverse (WTDiff) gravity in a general space-time dimension. First of all, we clarify a classical equivalence among three kinds of gravitational theories, those are, the conformally invariant scalar tensor gravity, Einstein's general relativity and the WTDiff gravity via the gauge-fixing procedure. Secondly, we show that in the WTDiff gravity the cosmological constant is a mere integration constant as in unimodular gravity, but it does not receive any radiative corrections unlike the unimodular gravity. A key point in this proof is to construct a covariantly conserved energy-momentum tensor, which is achieved on the basis of this equivalence relation. Thirdly, we demonstrate that the Noether current for the Weyl transformation is identically vanishing, thereby implying that the Weyl symmetry existing in both the conformally invariant scalar tensor gravity and the WTDiff gravity is a ''fake'' symmetry. We find it possible to extend this proof to all matter fields, i.e. the Weyl-invariant scalar, vector and spinor fields. Fourthly, it is explicitly shown that in the WTDiff gravity the Schwarzschild black hole metric and a charged black hole one are classical solutions to the equations of motion only when they are expressed in the Cartesian coordinate system. Finally, we consider the Friedmann-Lemaitre-Robertson-Walker (FLRW) cosmology and provide some exact solutions. (orig.)

  15. A&T Sector Note on the PS transverse feedback

    CERN Document Server

    Coly, Marcel; Blas, Alfred; Sterbini, Guido; CERN. Geneva. ATS Department

    2017-01-01

    In a particle accelerator, several contributions can degrade the beam quality and particularly the beam transverse emittance. In this document we will describe a system used in the CERN Proton Synchrotron (PS) to cope with the injection steering errors and the transverse instabilities: the PS transverse feedback (PS TFB). As time progresses, this system is also being used for other purpose, to increase in a controlled way the beam transverse emittance and to excite the beam for the Multi-Turn-Extraction (MTE). In 2016, it has been successfully used on some operational beams to damp injection oscillations. This allowed to test the reliability of the system for its operational deployment. A piquet service is available in case of problem.

  16. Transverse combining of nonrelativistic beams in a multiple beam induction linac

    International Nuclear Information System (INIS)

    Celata, C.M.; Faltens, A.; Judd, D.L.; Smith, L.; Tiefenback, M.G.

    1987-01-01

    Emittance growth of beams during transverse combining has been studied computationally and experimentally for Heavy Ion Fusion applications, and the theory and results are presented. A hardware design is also discussed

  17. Ion-pair vortex assisted liquid-liquid microextraction with back extraction coupled with high performance liquid chromatography-UV for the determination of metformin in plasma.

    Science.gov (United States)

    Alshishani, Anas; Makahleh, Ahmad; Yap, Hui Fang; Gubartallah, Elbaleeq Adam; Salhimi, Salizawati Muhamad; Saad, Bahruddin

    2016-12-01

    A new sample preparation method, ion-pair vortex assisted liquid-liquid microextraction (VALLME-BE), for the determination of a highly polar anti-diabetic drug (metformin) in plasma sample was developed. The VALLME-BE was performed by diluting the plasma in borate buffer and extracted to 150µL 1-octanol containing 0.2M di-(2-ethylhexyl)phosphoric acid as intermediate phase. The drug was next back-extracted into 20µL of 0.075M HCl solution. The effects of pH, ion-pair concentration, type of organic solvent, volume of extraction phases, ionic strength, vortexing and centrifugation times on the extraction efficiency were investigated. The optimum conditions were at pH 9.3, 60s vortexing and 2min centrifugation. The microextract, contained metformin and buformin (internal standard), was directly injected into a HPLC unit using C1 column (250mm×4.6mm×10µm) and detected at 235nm. The method was validated and calibration curve was linear with r 2 >0.99 over the range of 20-2000µgL -1 . The limits of detection and quantitation were 1.4 and 4.1µgL -1 , respectively. The accuracy was within 94.8-108% of the nominal concentration. The relative standard deviation for inter- and intra-day precision was less than 10.8%. The method was conveniently applied for the determination of metformin in plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Kinesthetic Transverse Wave Demonstration

    Science.gov (United States)

    Pantidos, Panagiotis; Patapis, Stamatis

    2005-09-01

    This is a variation on the String and Sticky Tape demonstration "The Wave Game," suggested by Ron Edge. A group of students stand side by side, each one holding a card chest high with both hands. The teacher cues the first student to begin raising and lowering his card. When he starts lowering his card, the next student begins to raise his. As succeeding students move their cards up and down, a wave such as that shown in the figure is produced. To facilitate the process, students' motions were synchronized with the ticks of a metronome (without such synchronization it was nearly impossible to generate a satisfactory wave). Our waves typically had a frequency of about 1 Hz and a wavelength of around 3 m. We videotaped the activity so that the students could analyze the motions. The (17-year-old) students had not received any prior instruction regarding wave motion and did not know beforehand the nature of the exercise they were about to carry out. During the activity they were asked what a transverse wave is. Most of them quickly realized, without teacher input, that while the wave propagated horizontally, the only motion of the transmitting medium (them) was vertical. They located the equilibrium points of the oscillations, the crests and troughs of the waves, and identified the wavelength. The teacher defined for them the period of the oscillations of the motion of a card to be the total time for one cycle. The students measured this time and then several asserted that it was the same as the wave period. Knowing the length of the waves and the number of waves per second, the next step can easily be to find the wave speed.

  19. Usage of X-ray absorption spectroscopy and extractive fractionation in studies of the Cu (II and Zn (II ions in soils

    Directory of Open Access Journals (Sweden)

    Dina Nevidomskaya

    2014-12-01

    Full Text Available XANES spectroscopy is an effective method for the study of bonds between metals and soil components. The study of structural organization in different soil samples and soil phases saturated with Cu2+ and Zn2+ ions by using XANES allowed determining the mechanism of their interaction with soil phases and all the chemical bindings taken place in the course of this process. Changes in the structure of the metal ion, in particular breakdown of the symmetry of electron orbits of atoms, take place due to interaction with soil components. Application of this method demonstrated that the state of copper and zinc introduced in chernozem as oxides did not change after one year of incubation. Copper is absorbed after being introduced as soluble salts, and copper ions are incorporated in the octahedral and tetrahedral sites of minerals and bonded with humic materials at the expense of covalent bond and the formation of coordination humate copper complexes. Zinc included into octahedric structures of layered minerals and hydro(oxides can be inner-and outer-sphere adsorbed. It is shown that the action of the metal bound to soil components becomes weakened in case of increasing the Cu and Zn load (from 2000 to 10000 mg/kg especially applied in the form of soluble salts. Extractive fractionation of metal compounds in chernozem samples, artificially contaminated with copper and zinc salts serves as evidence of absorbing the applied Cu2+ ions by the soil organic matter and Zn2+ ions – by silicates, carbonates, and Fe-Mn oxides.

  20. Silica chemically bonded N-propyl kriptofix 21 and 22 with immobilized palladium nanoparticles for solid phase extraction and preconcentration of some metal ions

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, Mehrorang, E-mail: m_ghaedi@mail.yu.ac.ir [Chemistry Department, Yasouj University, Yasouj, 75914-353 (Iran, Islamic Republic of); Niknam, Khodabakhsh, E-mail: niknam@pgu.ac.ir [Chemistry Department, Faculty of Sciences, Persian Gulf University, Bushehr, 75169 (Iran, Islamic Republic of); Zamani, Saeed; Abasi Larki, Habib [Chemistry Department, Islamic Azad University, Omidiyeh Branch, Omidiyeh (Iran, Islamic Republic of); Roosta, Mostafa [Chemistry Department, Yasouj University, Yasouj, 75914-353 (Iran, Islamic Republic of); Soylak, Mustafa [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2013-08-01

    Silica gel chemically bonded N-propyl kriptofix 21 (SBNPK 21) and N-propyl kriptofix 22 (SBNPK 22) and subsequently immobilized with palladium nanoparticles (PNP-SBNPK 21 and PNP-SBNPK 22) to produce two new complexing lipophilic materials. Then these novel sorbents were applied for the enrichment of some metal ions and their subsequent determination by flame atomic absorption spectroscopy (FAAS). The influences of the variables including pH, amount of solid phase, sample flow rate, eluent conditions and sample volume on the metal ion recoveries were investigated. The detection limit of proposed method was in the interval 2.1–2.3 and 1.7–2.8 ng mL{sup −1} for PNP-SBNPK 21 and PNP-SBNPK 22 respectively, while the preconcentration factor was 80 for two sorbents. The relative standard deviations of recoveries were between 1.23–1.31 and 1.28–1.49 for PNP-SBNPK 21 and PNP-SBNPK 22 respectively. The method has high sorption-preconcentration efficiency even in the presence of various interfering ions. Due to the reasonable selectivity of proposed method, the relative standard deviation of recoveries of all understudied metal ions in some complicated matrices was less than 3.0%. Highlights: • Highly selective sorbents for solid phase extraction were synthesized. • The method has been successfully applied for the determination of trace metals ions. • Excellent properties of the sorbent have been illustrated in detail.

  1. Comparing Multicomponent Erlang Distribution and Lévy Distribution of Particle Transverse Momentums

    International Nuclear Information System (INIS)

    Wei, Hua-Rong; Chen, Ya-Hui; Gao, Li-Na; Liu, Fu-Hu

    2014-01-01

    The transverse momentum spectrums of final-state products produced in nucleus-nucleus and proton-proton collisions at different center-of-mass energies are analyzed by using a multicomponent Erlang distribution and the Lévy distribution. The results calculated by the two models are found in most cases to be in agreement with experimental data from the Relativistic Heavy Ion Collider (RHIC) and the Large Hadron Collider (LHC). The multicomponent Erlang distribution that resulted from a multisource thermal model seems to give a better description as compared with the Lévy distribution. The temperature parameters of interacting system corresponding to different types of final-state products are obtained. Light particles correspond to a low temperature emission, and heavy particles correspond to a high temperature emission. Extracted temperature from central collisions is higher than that from peripheral collisions

  2. Effect of organic acids produced by penicillium notatum on the extraction of metals ions from brown shale

    International Nuclear Information System (INIS)

    Bhatti, H.N.; Sarwar, S.; Ilyas, S.

    2012-01-01

    Preset study was undertaken to check the bio leaching feasibility of brown shale with Penicillium notatum by using different carbon sources. Large quantities of the metal ions are embodied in shales that can be recovered. Presently available techniques (pyrometallurgical and hydrometallurgical) are expensive or may have a negative impact on the environment. Penicillium notatum exhibited a good potential in generating varieties of organic acids effective for metal ions solubilization. Maximum leaching of Cu (91.55 %) and Mg (79.83 %) was obtained with glucose as substrate while maximum recovery of Mn (71.46 %) was obtained in medium having molasses as substrate. (author)

  3. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    International Nuclear Information System (INIS)

    Ikeda, S.; Takahashi, K.; Okamura, M.; Horioka, K.

    2016-01-01

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons

  4. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, S., E-mail: ikeda.s.ae@m.titech.ac.jp [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0108 (Japan); Takahashi, K. [Department of Electrical Engineering, Nagaoka University of Technology, Nagaoka, Niigata 940-2137 (Japan); Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973-5000 (United States); Horioka, K. [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan)

    2016-02-15

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  5. Behavior of moving plasma in solenoidal magnetic field in a laser ion source

    Science.gov (United States)

    Ikeda, S.; Takahashi, K.; Okamura, M.; Horioka, K.

    2016-02-01

    In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

  6. Rapid analysis of pesticide residues in drinking water samples by dispersive solid-phase extraction based on multiwalled carbon nanotubes and pulse glow discharge ion source ion mobility spectrometry.

    Science.gov (United States)

    Zou, Nan; Gu, Kejia; Liu, Shaowen; Hou, Yanbing; Zhang, Jialei; Xu, Xiang; Li, Xuesheng; Pan, Canping

    2016-03-01

    An analytical method based on dispersive solid-phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass-mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4- to 48.7-fold (theoretical enrichment factor was 50-fold). The detection limits of pesticides were 0.01∼0.77 μg/kg. The linear range was 0.005-0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high-performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. FY08 parameters for the injection, acceleration, and extraction of gold ions and deuterons in the booster, AGS, and RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, C.J.

    2010-08-01

    A Gold ion with charge eQ has N = 197 Nucleons, Z = 79 Protons, and (Z-Q) electrons. (Here Q is an integer and e is the charge of a single proton.) The mass is m = au - Qm{sub e} + E{sub b}/c{sup 2} (1) where a = 196.966552 is the relative atomic mass [1, 2] of the neutral Gold atom, u = 931.494013 MeV/c{sup 2} is the unified atomic mass unit [3], and m{sub e}c{sup 2} = .510998902 MeV is the electron mass [3]. E{sub b} is the binding energy of the Q electrons removed from the neutral Gold atom. This amounts to 0.332 MeV for the helium-like gold ion (Q = 77) and 0.517 MeV for the fully stripped ion. For the Au{sup 31+} ion we have E{sub b} = 13.5 keV. These numbers are given in Ref. [4]. The deuteron mass [3] is 1875.612762(75) MeV/c{sup 2}.

  8. FY10 parameters for the injection, acceleration, and extraction of gold ions in booster, AGS, and RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, C.J.

    2010-08-01

    A Gold ion with charge eQ has N = 197 Nucleons, Z = 79 Protons, and (Z-Q) electrons. (Here Q is an integer and e is the charge of a single proton.) The mass is m = au - Qm{sub e} + E{sub b}/c{sup 2} (1) where a = 196.966552 is the relative atomic mass [1, 2] of the neutral Gold atom, u = 931.494013 MeV/c{sup 2} is the unified atomic mass unit [3], and m{sub e}c{sup 2} = .510998902 MeV is the electron mass [3]. E{sub b} is the binding energy of the Q electrons removed from the neutral Gold atom. This amounts to 0.332 MeV for the helium-like gold ion (Q = 77) and 0.517 MeV for the fully stripped ion. For the Au{sup 31+} ion we have E{sub b} = 13.5 keV. These numbers are given in Ref. [4].

  9. FY08 parameters for the injection, acceleration, and extraction of gold ions and deuterons in the booster, AGS, and RHIC

    International Nuclear Information System (INIS)

    Gardner, C.J.

    2010-01-01

    A Gold ion with charge eQ has N = 197 Nucleons, Z = 79 Protons, and (Z-Q) electrons. (Here Q is an integer and e is the charge of a single proton.) The mass is m = au - Qm e + E b /c 2 (1) where a = 196.966552 is the relative atomic mass (1, 2) of the neutral Gold atom, u = 931.494013 MeV/c 2 is the unified atomic mass unit (3), and m e c 2 = .510998902 MeV is the electron mass (3). E b is the binding energy of the Q electrons removed from the neutral Gold atom. This amounts to 0.332 MeV for the helium-like gold ion (Q = 77) and 0.517 MeV for the fully stripped ion. For the Au 31+ ion we have E b = 13.5 keV. These numbers are given in Ref. (4). The deuteron mass (3) is 1875.612762(75) MeV/c 2 .

  10. Trace-level mercury ion (Hg2+) analysis in aqueous sample based on solid-phase extraction followed by microfluidic immunoassay.

    Science.gov (United States)

    Date, Yasumoto; Aota, Arata; Terakado, Shingo; Sasaki, Kazuhiro; Matsumoto, Norio; Watanabe, Yoshitomo; Matsue, Tomokazu; Ohmura, Naoya

    2013-01-02

    Mercury is considered the most important heavy-metal pollutant, because of the likelihood of bioaccumulation and toxicity. Monitoring widespread ionic mercury (Hg(2+)) contamination requires high-throughput and cost-effective methods to screen large numbers of environmental samples. In this study, we developed a simple and sensitive analysis for Hg(2+) in environmental aqueous samples by combining a microfluidic immunoassay and solid-phase extraction (SPE). Using a microfluidic platform, an ultrasensitive Hg(2+) immunoassay, which yields results within only 10 min and with a lower detection limit (LOD) of 0.13 μg/L, was developed. To allow application of the developed immunoassay to actual environmental aqueous samples, we developed an ion-exchange resin (IER)-based SPE for selective Hg(2+) extraction from an ion mixture. When using optimized SPE conditions, followed by the microfluidic immunoassay, the LOD of the assay was 0.83 μg/L, which satisfied the guideline values for drinking water suggested by the United States Environmental Protection Agency (USEPA) (2 μg/L; total mercury), and the World Health Organisation (WHO) (6 μg/L; inorganic mercury). Actual water samples, including tap water, mineral water, and river water, which had been spiked with trace levels of Hg(2+), were well-analyzed by SPE, followed by microfluidic Hg(2+) immunoassay, and the results agreed with those obtained from reduction vaporizing-atomic adsorption spectroscopy.

  11. Thiacalix[4]arene derivatives as extractants for metal ions in aqueous solutions: Application to the selective facilitated transport of Ag(I)

    Energy Technology Data Exchange (ETDEWEB)

    Zaghbani, Asma [Laboratoire Eau et Technologies Membranaires, CERTE, BP 273, 8020 Soliman (Tunisia); Fontas, Claudia [Department of Chemistry, University of Girona, 17071 Girona (Spain)], E-mail: claudia.fontas@udg.edu; Hidalgo, Manuela [Department of Chemistry, University of Girona, 17071 Girona (Spain); Tayeb, Rafik; Dhahbi, Mahmoud [Laboratoire Eau et Technologies Membranaires, CERTE, BP 273, 8020 Soliman (Tunisia); Vocanson, Francis; Lamartine, Roger [Universite de Lyon, Lyon, F-69003 (France); Universite Lyon 1, Villeurbanne, F-69622 (France); CNRS, UMR 5246, ICBMS, equipe CSAp, 43 boulevard du 11 novembre 1918, Villeurbanne, F-69622 (France); Seta, Patrick [Institut Europeen des Membranes, UMR CNRS 5635, 1919 route de Mende, 34293 Montpellier (France)

    2008-07-01

    The complexation abilities of different thiacalix[4]arene derivatives towards some rare earth metal ions, metallic pollutants, and noble metals have been investigated in liquid-liquid experiments. Thiacalix[4]arene dissolved in chloroform effectively extracts Pd(II) (in acidic chloride media) and also Ag(I), Cd(II), Sm(III) and Ce(III), all buffered at pH 6 or 8. The modification of this compound to form an amide derivative results in an effective extraction of noble metals, ranked according to Au(III) > Pd(II) > Pt(IV) > Ag(I). Moreover, a supported liquid membrane system for silver transport has been developed based on thiacalix[4]arene dissolved in NPOE, and parameters affecting its efficiency have been investigated, such as the stripping composition and the pH of the feed solution. Finally, the selectivity of the membrane system has been evaluated by using as feed sources mixtures of silver and other metal ion000.

  12. A simple synthetic route of N-doped mesoporous carbon derived from casein extracted with cobalt ions for high rate performance supercapacitors

    International Nuclear Information System (INIS)

    Jia, Shaopei; Wang, Yanhui; Tian, Pengfei; Zhou, Shuyu; Cai, Haixia; Gao, Hongwei; Zang, Jianbing

    2017-01-01

    Highlights: •NMC is prepared by pyrolysis of cobalt-containing casein. •Cobalt-containing casein is extracted from the pure milk by cobalt ions. •The cobalt element increases the specific surface area and the N doping amount. •NMC exhibits high specific capacitance, high rate capability, and excellent cycling stability. -- Abstract: Nitrogen-doped mesoporous carbon (NMC) was synthesized via pyrolysis of cobalt-containing casein obtained by extraction from pure milk with the auxiliary of cobalt ions. The cobalt element in casein promoted specific surface area and N element doping amount of casein-derived porous carbon. The N-doped porous carbon obtained by carbonization at 800 °C (NPC-800) possessed a specific surface area of ∼886.7 m 2 g −1 , and the mesoporous size was centered at 2.7 and 7 nm. X-ray photoelectron spectroscopy analysis showed that the nitrogen content of NPC-800 was 3.29 at%. The NPC-800 was explored as a symmetric supercapacitor, which exhibited specific capacity of 380 F g −1 at a current density of 0.5 A g −1 , 218 F g −1 at a current density of 20 A g −1 , and high capacitance retention of 91.3% after charging/discharging 5,000 cycles.

  13. On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium

    Energy Technology Data Exchange (ETDEWEB)

    Yousefi, Seyed Reza; Zolfonoun, Ehsan [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). NFCRS

    2016-07-01

    In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L{sup -1} were obtained for uranium and thorium, respectively.

  14. Frequency resolved transverse mode instability in rod fiber amplifiers

    DEFF Research Database (Denmark)

    Johansen, Mette Marie; Laurila, Marko; Maack, Martin D.

    2013-01-01

    Frequency dynamics of transverse mode instabilities (TMIs) are investigated by testing three 285/100 rod fibers in a single-pass amplifier setup reaching up to ~200W of extracted output power without beam instabilities. The pump power is increased well above the TMI threshold to uncover output dy...

  15. Higgs boson transverse momentum distribution

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I will review  the recent progress in understanding Higgs boson transverse momentum distribution focusing on effects that go beyond the point-like approximation for the Higgs-glue interaction vertex.

  16. Transverse correlations in multiphoton entanglement

    International Nuclear Information System (INIS)

    Wen Jianming; Rubin, Morton H.; Shih Yanhua

    2007-01-01

    We have analyzed the transverse correlation in multiphoton entanglement. The generalization of quantum ghost imaging is extended to the N-photon state. The Klyshko's two-photon advanced-wave picture is generalized to the N-photon case

  17. Theory of kinetics and equilibrium of ion exchange-adsorption and mechanism of extracting uranium from sea-water with titanic gel

    International Nuclear Information System (INIS)

    Ai Hongtao

    1989-01-01

    An isothermal equation for ion exchange-adsorption is derived by mass action law. The equation can be used to sum up empirical and semiempirical formulas of the exchange adsorption, such as Gapon Equation, Sips Formula, Langmuir Equation and Freundlich Formula. In this paper, by adopting the ion exchange reaction to act as the determining step of the ion exchange adsorption kinetics, and exchange-adsorption kinetics equation is derived. It is verified by he results of a series of experiments in which uranium is extracted form enriched sea-water and natural sea-water with hydrous titanium oxide (titanic gel). This equation can be used to explain not only the results of test which have been applied to prove fast intraparticle diffusion of liquid film deffusion mechanism, but also test data which can be expalined by the co-controlling fast intraparticle and liquid film diffusion, and the kinetic data which can not be clarified by diffusion mechanism. It is proposed that the mechanism of the exchange adsorption of uranium from sea-water with titanic gel is a cationic exchange reaction. A method for calculating the quantity of exchange-adsorption at equilibrium is also given

  18. Flame atomic absorption spectrometric determination of trace amounts of heavy metal ions after solid phase extraction using modified sodium dodecyl sulfate coated on alumina

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, Mehrorang [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of)], E-mail: m_ghaedi@mail.yu.ac.ir; Niknam, Khodabakhsh [Chemistry Department, Persian Gulf University, Bushehr (Iran, Islamic Republic of); Shokrollahi, Ardeshir; Niknam, Ebrahim; Rajabi, Hamid Reza [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of); Soylak, Mustafa [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2008-06-30

    A sensitive and selective solid phase extraction procedure for the determination of traces of Cu(II), Zn(II), Pb(II) and Fe(III) has been developed. An alumina-sodium dodecyl sulfate (SDS) coated on with meso-phenyl bis(indolyl) methane (MPBIM) was used for preconcentration and determination of Cu(II), Zn(II), Pb(II) and Fe(III) ions by flame atomic absorption spectrometry. The analyte ions were adsorbed quantitatively on adsorbent due to their complexation with MPBIM. Adsorbed metals were quantitatively eluted using 6 mL of 4 mol L{sup -1} nitric acid. The effects of parameters such as pH, amount of alumina, amount of MBITP, flow rate, type and concentration of eluting agent were examined. The effects of interfering ions on the separation-preconcentration of analytes were also investigated. The relative standard deviation of the method was found to be less than 3.0%. The presented procedure was successfully applied for determination of analytes in real samples.

  19. Dependence of equilibrium properties of channeled particles on transverse quasi temperature

    International Nuclear Information System (INIS)

    Kashlev, Yu.A.

    2006-01-01

    Quasi-equilibrium and kinetic characteristics of channeled particles are investigated by methods of nonequilibrium statistical thermodynamics. The equilibrium equation of the transverse energy of fast particles and the equilibrium equation of the transverse momentum of particles are derived. It is shown that equilibrium equations solution permits to obtain the expression for the transverse quasi-temperature of the channeled particle subsystem. The quasi-equilibrium angular distribution of particles after transmission through a thin monocrystal and the angular distribution at backscattering are studied. The evaluated data of the transverse quasi-temperature are presented for the case of iodine ion channeling through silver crystals [ru

  20. Performance of the transverse coupled-bunch feedback system in the SRRC

    International Nuclear Information System (INIS)

    Hsu, K.T.; Kuo, C.C.; Kuo, C.H.; Lin, K.K.; Ueng, T.S.; Weng, W.T.

    1996-01-01

    A transverse feedback system has been implemented and commissioned in the SRRC storage ring to suppress transverse coupled-bunch oscillations of the electron beam. The system includes transverse oscillation detectors, notch filter, baseband quadrature processing circuitry, power amplifiers, and kickers. To control a large number of transverse coupled-bunch modes, the system is broad-band, bunch-by- bunch in nature. Because the system is capable of bunch-by-bunch correction, it can also be useful for suppressing instabilities introduced by ions. The sextupole strength was then reduced to improve dynamic aperture and hence lifetime of the storage ring

  1. Ion exchange separation of lead from strontium in certified reference samples and spectrophotometric determination of lead as extractable ion-pair of eosin2- and the lead-cryptand (2.2.2)2+ complex

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Shayah, O.

    2004-01-01

    A two-step procedure including anion exchange separation of lead from strontium in geological reference samples and a spectrophotometric determination of the separated lead as lead-cryptate (2.2.2) complex is presented. The exchangeable anion Cl - of the ion exchange resin (Dowex 1x4) is changed to Br - in 6M HBr solution. Lead is quantitatively retained in the column from 0.5M HBr medium, while Sr 2+ , Ba 2+ , Ca 2+ , Mg 2+ , Na + , K + , Fe 3+ , Cr 3+ , and Al 3+ are passed through. Subsequently the retained Ph is eluted from the column with 6M HBr. The separation efficiency of the resin is controlled using mixed standard solution of (Pb, Sr, Ca, Mg, Ba, Na, K, Fe, Cr and Al), and radioactive tracer of 85 Sr and 131 Ba. The resin selectivity coefficient (K) of separating Pb from Sr is found to be K S r P b∼10 9 . The Spectrophotometric method of lead determination is based on the formation of lead-crytate (2.2.2) complex at pH 8.3 using borate/HCl as a buffer solution. Then the ion-pair of eosin 2+ and lead-cryptand (2.2.2) complex is extracted with chloroform, finally the absorbance of the extractable legend is measured at 550 nm. The extraction recovery, accuracy, precision, linearity and detection limit of the spectrophotometric method are 99.58%, 1.7%, 0.080μg mL -1 , o-9μg mL -1 , and 0.060μg mL -1 , respectively. (author)

  2. Selective Solid-Phase Extraction of Zinc(II) from Environmental Water Samples Using Ion Imprinted Activated Carbon.

    Science.gov (United States)

    Moniri, Elham; Panahi, Homayon Ahmad; Aghdam, Khaledeh; Sharif, Amir Abdollah Mehrdad

    2015-01-01

    A simple ion imprinted amino-functionalized sorbent was synthesized by coupling activated carbon with iminodiacetic acid, a functional compound for metal chelating, through cyanoric chloride spacer. The resulting sorbent has been characterized using FTIR spectroscopy, elemental analysis, and thermogravimetric analysis and evaluated for the preconcentration and determination of trace Zn(II) in environmental water samples. The optimum pH value for sorption of the metal ion was 6-7.5. The sorption capacity of the functionalized sorbent was 66.6 mg/g. The chelating sorbent can be reused for 10 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 100% was obtained for the metal ion with 0.5 M nitric acid as the eluent. Compared with nonimprinted polymer particles, the prepared Zn-imprinted sorbent showed high adsorption capacity, significant selectivity, and good site accessibility for Zn(II). Scatchard analysis revealed that the homogeneous binding sites were formed in the polymer. The equilibrium sorption data of Zn(II) by modified resin were analyzed by Langmuir, Freundlich, Temkin, and Redlich-Peterson models. Based on equilibrium adsorption data, the Langmuir, Freundlich, and Temkin constants were determined as 0.139, 12.82, and 2.34, respectively, at 25°C.

  3. Extraction of Lanthanide and Actinide Ions from Aqueous Mixtures Using a Carboxylic Acid-Functionalized Porous Aromatic Framework

    Science.gov (United States)

    2016-01-01

    Porous aromatic frameworks (PAFs) incorporating a high concentration of acid functional groups possess characteristics that are promising for use in separating lanthanide and actinide metal ions, as required in the treatment of radioactive waste. These materials have been shown to be indefinitely stable to concentrated acids and bases, potentially allowing for multiple adsorption/stripping cycles. Additionally, the PAFs combine exceptional features from MOFs and inorganic/activated carbons giving rise to tunable pore surfaces and maximum chemical stability. Herein, we present a study of the adsorption of selected metal ions, Sr2+, Fe3+, Nd3+, and Am3+, from aqueous solutions employing a carbon-based porous aromatic framework, BPP-7 (Berkeley Porous Polymer-7). This material displays high metal loading capacities together with excellent adsorption selectivity for neodymium over strontium based on Langmuir adsorption isotherms and ideal adsorbed solution theory (IAST) calculations. Based in part upon X-ray absorption spectroscopy studies, the stronger adsorption of neodymium is attributed to multiple metal ion and binding site interactions resulting from the densely functionalized and highly interpenetrated structure of BPP-7. Recyclability and combustibility experiments demonstrate that multiple adsorption/stripping cycles can be completed with minimal degradation of the polymer adsorption capacity. PMID:27163056

  4. Solid-phase extraction of copper, iron and zinc ions on Bacillus thuringiensis israelensis loaded on Dowex optipore V-493

    Energy Technology Data Exchange (ETDEWEB)

    Tuzen, Mustafa; Melek, Esra [Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat (Turkey); Soylak, Mustafa [Erciyes University, Faculty of Science and Arts, Chemistry Department, 38039 Kayseri (Turkey)], E-mail: msoylak@gmail.com

    2008-11-30

    Bacillus thuringiensis israelensis loaded on Dowex optipore V-493 as new adsorbent for the separation-preconcentration of heavy metal ions has been proposed. The analytical conditions for the quantitative recoveries of copper(II), iron(III) and zinc(II) including pH, amounts of adsorbent, sample volume, etc. were investigated. The influences of alkaline and earth alkaline ions were also reported. The recovery values for the analytes are generally higher than 95%. The preconcentration factor was 37. The limit of detections of the analyte ions (k = 3, N = 21) were 1.14 {mu}g L{sup -1} for copper, 2.01 {mu}g L{sup -1} for iron and 0.14 {mu}g L{sup -1} for zinc. The relative standard deviations of the determinations were found to be lower than 9%. The procedure was validated by analyzing copper, iron and zinc contents in two certified reference materials, NRCC-SLRS-4 Riverine water and NIST SRM 1515 Apple leaves. Agreements between the obtained results and the certified values were achieved. The developed preconcentration method was applied in the flame atomic absorption spectrometric determination of copper, iron and zinc in several samples including a multivitamin-multimineral tablet, dialysis solutions, natural waters and some food samples.

  5. Lanthanide and actinide extractions with cobalt bis(dicarbollide) ion derivatives covalently bonded to diglycolyl diamide platform

    Czech Academy of Sciences Publication Activity Database

    Lučaníková, M.; Selucký, P.; Rais, J.; Grüner, Bohumír; Kvíčalová, Magdalena

    2011-01-01

    Roč. 1, č. 1 (2011), s. 89-95 ISSN 2193-2875 R&D Projects: GA ČR GA104/09/0668; GA MŠk LC523 Institutional research plan: CEZ:AV0Z40320502 Keywords : Dicarbollides derivatives * TODGA * Liquid-liquid extraction * Lanthanides * Actinides Subject RIV: CA - Inorganic Chemistry

  6. Production of citric acid using its extraction wastewater treated by anaerobic digestion and ion exchange in an integrated citric acid-methane fermentation process.

    Science.gov (United States)

    Xu, Jian; Chen, Yang-Qiu; Zhang, Hong-Jian; Tang, Lei; Wang, Ke; Zhang, Jian-Hua; Chen, Xu-Sheng; Mao, Zhong-Gui

    2014-08-01

    In order to solve the problem of extraction wastewater pollution in citric acid industry, an integrated citric acid-methane fermentation process is proposed in this study. Extraction wastewater was treated by mesophilic anaerobic digestion and then used to make mash for the next batch of citric acid fermentation. The recycling process was done for seven batches. Citric acid production (82.4 g/L on average) decreased by 34.1 % in the recycling batches (2nd-7th) compared with the first batch. And the residual reducing sugar exceeded 40 g/L on average in the recycling batches. Pigment substances, acetic acid, ammonium, and metal ions in anaerobic digestion effluent (ADE) were considered to be the inhibitors, and their effects on the fermentation were studied. Results indicated that ammonium, Na(+) and K(+) in the ADE significantly inhibited citric acid fermentation. Therefore, the ADE was treated by acidic cation exchange resin prior to reuse to make mash for citric acid fermentation. The recycling process was performed for ten batches, and citric acid productions in the recycling batches were 126.6 g/L on average, increasing by 1.7 % compared with the first batch. This process could eliminate extraction wastewater discharge and reduce water resource consumption.

  7. Two solid-phase recycling method for basic ionic liquid [C4mim]Ac by macroporous resin and ion exchange resin from Schisandra chinensis fruits extract.

    Science.gov (United States)

    Ma, Chun-hui; Zu, Yuan-gang; Yang, Lei; Li, Jian

    2015-01-22

    In this study, two solid-phase recycling method for basic ionic liquid (IL) 1-butyl-3-methylimidazolium acetate ([C4mim]Ac) were studied through a digestion extraction system of extracting biphenyl cyclooctene lignans from Schisandra chinensis. The RP-HPLC detection method for [C4mim]Ac was established in order to investigate the recovery efficiency of IL. The recycling method of [C4mim]Ac is divided into two steps, the first step was the separation of lignans from the IL solution containing HPD 5000 macroporous resin, the recovery efficiency and purity of [C4mim]Ac achieved were 97.8% and 67.7%, respectively. This method cannot only separate the lignans from [C4mim]Ac solution, also improve the purity of lignans, the absorption rate of lignans in [C4mim]Ac solution was found to be higher (69.2%) than that in ethanol solution (57.7%). The second step was the purification of [C4mim]Ac by the SK1B strong acid ion exchange resin, an [C4mim]Ac recovery efficiency of 55.9% and the purity higher than 90% were achieved. Additionally, [C4mim]Ac as solvent extraction of lignans from S. chinensis was optimized, the hydrolysis temperature was 90°C and the hydrolysis time was 2h. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Determination of the extractive capacity of para-tert butyl calix[8]arene octa-phosphinoylated towards uranyl ions from an aqueous-acidic-salty medium; Determinacion de la capacidad extractiva del p-ter-butilocalix[8]areno octa-fosfinoilado hacia iones uranilo de un medio acuo-acido salino

    Energy Technology Data Exchange (ETDEWEB)

    Serrano V, E. C.

    2011-07-01

    The extraction properties of octa-phosphinoylated para-tert butyl calix[8]arene (prepared in the laboratory) in chloroform towards uranyl ions from an aqueous-acidic-salty medium (HNO{sub 3}-3.5 NaNO{sub 3}) containing uranyl nitrate salt, was investigated. Two spectroscopic techniques UV/Vis and Luminescence were used for this study. The latter permitted analyze the fluorescence from the uranyl ions influenced by the surrounding medium. Both permitted to learn about the power of this calixarene as extractant towards the mentioned ions. Its extraction ability or capability using this calixarene at 5.91 x 10{sup -4} M towards the uranyl ions was 400% as determined by UV/Vis while fluorescence revealed 100% of uranyl ion extraction. A closed analysis of the results obtained by using these techniques revealed that the stoichiometry of the main extracted species was 1calixarene:2 uranyl ions. The loading capacity of the calixarene ligand towards the uranyl ions was also investigated using both techniques. UV/Vis resulted to be inadequate for quantifying exactly the loading capacity of the calixarene whereas luminescence was excellent indeed, using a 5.91 x 10{sup -4} M calixarene concentration, its loading capacity was 0.157 M of free uranyl ions from 0.161 M of uranyl ions present in the aqueous-acidic-salty medium. The extracts from the ability and capacity studies were concentrated to dryness, purified and the dried extracts were analyzed by infrared and neutron activation analysis. By these techniques it was demonstrated that during the extraction of the uranyl ions by the calixarene ligand they form thermodynamically and kinetically stable complexes, since in the solid state, the 1:2, calixarene; uranyl ions stoichiometry was kept with the minimum formula: (UO{sub 2}){sub 2}B{sub 8}bL{sup 8}(NO{sub 3}){sub 4}(H{sub 2}O){sub 4}CHCl{sub 3}(CH{sub 3}OH){sub 3} the methanol molecules come from its purification. It is proposed that B{sub 8}bL{sup 8} calixarene in

  9. Supercritical carbon dioxide extraction of electrolyte from spent lithium ion batteries and its characterization by gas chromatography with chemical ionization

    Science.gov (United States)

    Mönnighoff, Xaver; Friesen, Alex; Konersmann, Benedikt; Horsthemke, Fabian; Grützke, Martin; Winter, Martin; Nowak, Sascha

    2017-06-01

    The aging products of the electrolyte from a commercially available state-of-the-art 18650-type cell were investigated. During long term cycling a huge difference in their performance and lifetime at different temperatures was observed. By interpretation of a strong capacity fading of cells cycled at 20 °C compared to cells cycled at 45 °C a temperature depending aging mechanism was determined. To investigate the influence of the electrolyte on this fading, the electrolyte was extracted by supercritical fluid extraction (SFE) and then analyzed by gas chromatography (GC) with electron impact (EI) ionization and mass selective detection. To obtain more information with regard to the identification of unknown decomposition products further analysis with positive chemical ionization (PCI) and negative chemical ionization (NCI) was performed. 17 different volatile organic aging products were detected and identified. So far, seven of them were not yet known in literature and several formation pathways were postulated taking previously published literature into account.

  10. Single transverse-spin asymmetric in hardronic collisions

    International Nuclear Information System (INIS)

    Qiu, J.

    1995-01-01

    We provide a consistent treatment of single transverse-spin asymmetriesin hadronic collisions in terms of the generalized factorization theorem in perturbative QCD. The asymmetries in different physical processes, such as direct photon, single particle production, can be expressed in terms of a calculable partonic hard-part convoluted with universal three-parton correlation functions. We show that the observed single transverse- spin asymmtries in hadronic pion production can be understood, and used to extract the information on these correlation functions. With these correlation functions, predictions on single spin asymmetries in other processes can be made, and consequently, the theory can be tested

  11. High resolution studies of the origins of polyatomic ions in inductively coupled plasma-mass spectrometry, Part I. Identification methods and effects of neutral gas density assumptions, extraction voltage, and cone material

    International Nuclear Information System (INIS)

    Ferguson, Jill Wisnewski; Houk, R.S.

    2006-01-01

    Common polyatomic ions (ArO + , NO + , H 2 O + , H 3 O + , Ar 2 + , ArN + , OH + , ArH + , O 2 + ) in inductively coupled plasma-mass spectrometry (ICP-MS) are identified using high mass resolution and studied using kinetic gas temperatures (T gas ) determined from a dissociation reaction approach. Methods for making accurate mass measurements, confirming ion identifications, and correcting for mass bias are discussed. The effects of sampler and skimmer cone composition and extraction voltage on polyatomic ion formation are also explored. Neutral species densities at several locations in the extraction interface are estimated and the corresponding effects of the T gas value are calculated. The results provide information about the origins of background ions and indicate possible locations for their formation or removal

  12. Purification of gamma-amino butyric acid (GABA) from fermentation of defatted rice bran extract by using ion exchange resin

    Science.gov (United States)

    Tuan Nha, Vi; Phung, Le Thi Kim; Dat, Lai Quoc

    2017-09-01

    Rice bran is one of the significant byproducts of rice processing with 10 %w/w of constitution of whole rice grain. It is rich in nutrient compounds, including glutamic acid. Thus, it could be utilized for the fermentation with Lactobateria for synthesis of GABA, a valuable bioactive for antihypertensive effects. However, the concentration and purity of GABA in fermentation broth of defatted rice bran extract is low for production of GABA drug. This research focused on the purification of GABA from the fermentation broth of defatted rice bran extract by using cation exchange resin. The results indicate that, the adsorption isotherm of GABA by Purelite C100 showed the good agreement with Freundlich model, with high adsorption capacity. The effects of pH and concentration of NaCl in eluent on the elution were also investigated. The obtained results show that, at the operating conditions of elution as follows: pH 6.5, 0.8 M of NaCl in eluent, 0.43 of bed volume; concentration of GABA in accumulative eluent, the purity and recovery yield of GABA were 743.8 ppm, 44.0% and 84.2%, respectively. Results imply that, it is feasible to apply cation exchange resin for purification of GABA from fermentation broth of defatted rice bran extract.

  13. Transversal lightlike submanifolds of indefinite sasakian manifolds

    OpenAIRE

    YILDIRIM, Cumali; Yıldırım, Cumali; Şahin, Bayram

    2014-01-01

    We study both radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds. We give examples, investigate the geometry of distributions and obtain necessary and sufficient conditions for the induced connection on these submanifolds to be metric connection. We also study totally contact umbilical radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds and obtain a classification theorem for totally contact umbilical tr...

  14. Transversal lightlike submanifolds of indefinite sasakian manifolds

    OpenAIRE

    YILDIRIM, Cumali

    2010-01-01

    We study both radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds. We give examples, investigate the geometry of distributions and obtain necessary and sufficient conditions for the induced connection on these submanifolds to be metric connection. We also study totally contact umbilical radical transversal and transversal lightlike submanifolds of indefinite Sasakian manifolds and obtain a classification theorem for totally contact umbilical tr...

  15. Extraction of the high transverse momentum photons in proton + proton collisions at 200 GeV in the PHENIX experiment at RHIC; Isolation des photons de grande impulsion transverse dans les collisions proton+proton a 200 GeV dans l'experience PHENIX au RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Hadl Henni, Ahmed [Ecole doctorale STIM, Sciences et Technologies de l' Information et des Materiaux, Ecole Centrale de Nantes, Universite de Nantes, Ecole des Mines de Nantes, 1 rue de la Noe, BP 92101, 44321 Nantes Cedex 3 (France)

    2007-02-15

    Ultra-relativistic heavy ions collisions allow to reach a hot and dense matter. This new state, called Quarks and Gluons Plasma (QGP), would exist at the first moment of our universe according to the Big Bang theory. The PHENIX experiment, one of the interaction point of the RHIC collider at Brookhaven National Laboratory (USA), aims to study the QGP's signatures. Photons don't interact strongly with the matter and so are an accurate tool to explore the phase of QGP. Moreover photons are emitted during all the phases of the nuclear collision: from the initial state to the final hadronization. We will present a direct photon, produced by hard scattering process in the beginning of the collision, identification method (SICA, Spectroscopic Isolation Cut Analysis) applied on p + p collisions at 200 GeV. This method allows for a better discrimination between direct photons and the other contribution (mainly the electromagnetic decay of the neutral pion). One could find in this thesis the direct photon rate production obtained by SICA and compared to other analysis. With the p + p collisions we have an important reference for the more heavier collisions (Au + Au) where we assume the QGP formation. (author)

  16. Extraction method

    International Nuclear Information System (INIS)

    Stary, J.; Kyrs, M.; Navratil, J.; Havelka, S.; Hala, J.

    1975-01-01

    Definitions of the basic terms and of relations are given and the knowledge is described of the possibilities of the extraction of elements, oxides, covalent-bound halogenides and heteropolyacids. Greatest attention is devoted to the detailed analysis of the extraction of chelates and ion associates using diverse agents. For both types of compounds detailed conditions are given of the separation and the effects of the individual factors are listed. Attention is also devoted to extractions using mixtures of organic agents, the synergic effects thereof, and to extractions in non-aqueous solvents. The effects of radiation on extraction and the main types of apparatus used for extractions carried out in the laboratory are described. (L.K.)

  17. Lanthanide and actinide extractions with anionic ligands based on cobalt bis(dicarbollide) ions with covalently bonded CMPO functions

    Energy Technology Data Exchange (ETDEWEB)

    Selucky, P.; Rais, J.; Lucanikova, M. [Nuclear Research Inst. plc., Rez near Prague (Czech Republic); Gruener, B.; Kvicalova, M. [Inst. of Inorganic Chemistry, v.v.i., Academy of Sciences of the Czech Republic, Husinec-Rez near Prague (Czech Republic); Fejfarova, K. [Inst. of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic); Cisarova, I. [Charles Univ., Prague (Czech Republic). Dept. of Chemistry

    2008-07-01

    Compounds were synthesized with the aim to develop efficient extraction agents for liquid-liquid extraction of polyvalent cations, i.e. lanthanides and actinides from high-level activity nuclear waste. Compounds of general formulation [(8-CMPO-(CH{sub 2}-CH{sub 2}O){sub 2}-1,2-C{sub 2}B{sub 9}H{sub 10})(1',2'-C{sub 2}B{sub 9}H{sub 11})-3.3'-Co(III)] with different phosphorus and nitrogen substitution (CMPO={sup 2}R,{sup 3}R P(O)-(CH{sub 2}){sub n}C(O)N{sup 1}R, {sup 1}R = t-octyl, H, Ph, {sup 2}R=Ph, n-octyl, {sup 3}R=Ph, n = 1,2)-(4a to 4e), were prepared and characterized by combination of {sup 11}B NMR, {sup 1}H high field NMR, ESI-M.S., HPLC and other techniques. Molecular structure of the sodium complex of ligand 4a ({sup 1}R = t-octyl, {sup 2}R = {sup 3}R = Ph, n = 1) was determined by single crystal X-ray diffraction analysis. Effect of several modifications in the structure of 4a-4e on the extraction properties was outlined. The study resulted in the definition of ionic ligand with enhanced extraction efficiency for 4a,b (t-octyl and H on the amidic nitrogen atom) and a better solubility of 4a and 4d ({sup 1}R = t-octyl, {sup 2}R = n-Oct, {sup 1}R=Ph, n = 1) in less polar solvents. Low polar mixtures of hydrogenated tetrapropylene (TPH) hexyl methyl ketone (HMK) can be applied as an auxiliary solvent for 4a, selected for detailed studies, replacing thus the polar and less environmentally friendly nitro-, fluoro- and chloro- solvents used in the current dicarbollide liquid-liquid extraction process. Results of the fission products separation from the simulated PUREX feed using 4a are presented inclusive procedures for Eu{sup 3+} stripping. (orig.)

  18. Interaction of Fe(II) with Polyacrylic Acid as a Simplification of Humic Acid: Comparison of Ion Exchange and Solvent Extraction Methods

    International Nuclear Information System (INIS)

    Budi Setiawan

    2007-01-01

    To estimate the safety assessment around the disposal facility, the interaction behavior of radionuclides/metal ions into organic material (such as humic acids) exist in natural water becomes an important study. To avoid the effect of heterogeneous composition of humic acid, polyacrylic acids (abbrev. APA) was used as are representative of homogeneous polymeric weak acid. The experiments have been carried out by solvent extraction and ion exchange methods to find out the suitable method for the study of complex formation of Fe(II) with humic acid(AH) and APA. The solvent extraction experiment has been done by using diphenylthiocarbazone (dithizone) in CCl 4 and C Fe(II) were 10 -8 M to 10 -5 M, pH around 5 and I=0.1M NaCI. In ionic exchange experiment, C Fe(II) were 10 -8 to 10 -4 M, pH from 4.8 to 5.5 in I=0.1M NaCl. The apparent complex formation constant is defined as β α = [ML]/([M][R]), where [M] and [ML] are concentration of free and bound of Fe(II) and [R] is the concentration of dissociated carboxylic group in macromolecules of PAA. The results shown that, for solvent extraction experiments, variable concentration of Fe(II) had no appreciable influence on the distribution ratio of Fe(II)-polyacrylate at the tracer concentration with the log D to be 1.32 ± 0.03 (pcH 5.25). At macro concentration, the distribution ratio of Fe(II) becomes smaller due to oxidation and obtained log D value to be 1.04 ± 0.07 (pcH 5.34). An interest kind was observed at higher PAA concentration, the distribution ratio curve becomes higher presumably due to the problem on redox sensitive characteristic of Fe(II) and/or coagulation of Fe(II)-polyacrylate at the interface of aqueous-organic phases. In case of ionic exchange method, the plot of I/Kd versus [R] gives a straight line result indicating this method is appropriate and more superior compare than solvent extraction method to determine the complex formation constant. (author)

  19. Analysis of ecstasy in oral fluid by ion mobility spectrometry and infrared spectroscopy after liquid-liquid extraction.

    Science.gov (United States)

    Armenta, Sergio; Garrigues, Salvador; de la Guardia, Miguel; Brassier, Judit; Alcalà, Manel; Blanco, Marcelo

    2015-03-06

    We developed and evaluated two different strategies for determining abuse drugs based on (i) the analysis of saliva by ion mobility spectrometry (IMS) after thermal desorption and (ii) the joint use of IMS and infrared (IR) spectroscopy after liquid-liquid microextraction (LLME) to enable the sensitivity-enhanced detection and double confirmation of ecstasy (MDMA) abuse. Both strategies proved effective for the intended purpose. Analysing saliva by IMS after thermal desorption, which provides a limit of detection (LOD) of 160μgL(-1), requires adding 0.2M acetic acid to the sample and using the truncated negative second derivative of the ion mobility spectrum. The joint use of IMS and IR spectroscopy after LLME provides an LOD of 11μgL(-1) with the former technique and 800μgL(-1) with the latter, in addition to a limit of confirmation (LOC) of 1.5mgL(-1). Using IMS after thermal desorption simplifies the operational procedure, and using it jointly with IR spectroscopy after LLME allows double confirmation of MDMA abuse with two techniques based on different principles (viz., IMS drift times and IR spectra). Also, it affords on-site analyses, albeit at a lower throughput. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Pseudoscalar Meson Electroproduction and Transversity

    International Nuclear Information System (INIS)

    Goldstein, G.; Liuti, S.

    2011-01-01

    Exclusive meson leptoproduction from nucleons in the deeply virtual exchanged boson limit can be described by generalized parton distributions (GPDs). Including spin dependence in the description requires 8 independent quark-parton and gluon-parton functions. The chiral even subset of 4 quark-nucleon GPDs are related to nucleon form factors and to parton distribution functions. The chiral odd set of 4 quark-nucleon GPDs are related to transversity, the tensor charge, and other quantities related to transversity. Different meson or photon production processes access different combinations of GPDs. This is analyzed in terms of t-channel exchange quantum numbers, J PC and it is shown that pseudoscalar production can isolate chiral odd GPDs. There is a sensitive dependence in various cross sections and asymmetries on the tensor charge of the nucleon and other transversity parameters. In a second section, analyticity and completeness are shown to limit the partonic interpret ation of the GPDs in the ERBL region.