WorldWideScience

Sample records for transvaginal ultrasound-guided ovarian

  1. Transvaginal ultrasound ovarian diathermy: sheep as an experimental model

    Directory of Open Access Journals (Sweden)

    Pimentel Anita M

    2012-01-01

    Full Text Available Abstract Background Some techniques of transvaginal ovarian drilling have been previously described. Nevertheless a monopolar transvaginal ovarian cauterization, that use the expertise and safety of transvaginal puncture for oocyte captation seems to be an easier and feasible approach. The aim of this study was to develop a minimally invasive ovarian cauterization technique under transvaginal ultrasound control, and to evaluate the safety of the transvaginal ovarian monopolar cauterization, female sheep at reproductive age were used as an experimental model. Findings An experimental study was performed in a university research center. Seventeen female sheep (15 Corriedale e 2 Suffolk in reproductive age were submitted to transvaginal ovarian cauterization with a monopolar Valleylab Force 2 electrocautery. Macroscopic and microscopic lesions were assessed. Ovarian size were 1.31 cm2 ± 0,43 (Corriedale and 3.41 cm2 ± 0,64 (Suffolk. From 30 ovaries from Corriedale sheep punctured, only 3 were cauterized, presenting macroscopic and typical microscopic lesion. In the Suffolk sheep group, only one ovary was cauterized. No lesion could be found in the needle path. Conclusions This is the first experimental animal model described for ovarian cauterization needle guided by transvaginal ultrasound. The sheep does not seem to be the ideal animal model to study this technique. Another animal model, whose ovaries are better identified by transvaginal ultrasound should be sought for this technique, theoretically less invasive, before it could be offered safely to women with polycystic ovary syndrome.

  2. The impact of in situ methotrexate injection after transvaginal ultrasound-guided aspiration of ovarian endometriomas on ovarian response and reproductive outcomes during IVF-cycles

    Directory of Open Access Journals (Sweden)

    H.E. Shawki

    2012-06-01

    Conclusion(s: In situ methotrexate injection after transvaginal ultrasound-guided aspiration was a simple, safe and successful method for treating ovarian endometriomas with minimal effects on ovarian response. Short term effects on reproductive outcomes, risk of fetal loss or anomaly were minimal. Six months was enough as washout period of the drug prior to conception and was advisable to prevent the small chance of chromosomal abnormalities in the offspring.

  3. Prediction of endometriosis by transvaginal ultrasound in reproductive-age women with normal ovarian size

    OpenAIRE

    Tamer H. Said; Amal Z. Azzam

    2014-01-01

    Objective: To predict endometriosis by transvaginal ultrasound (TVS) in reproductive-age women with normal ovarian size. Design: Prospective study. Setting: El-Shatby Maternity Hospital, Alexandria University. Patients: 125 Women with symptoms suggestive of endometriosis and with normal ovarian size during TVS. Interventions: Patients were subjected to high frequency ultrasound and evaluated for the presence of ultrasound signs of endometriosis (TVS-based soft markers). All patien...

  4. Transvaginal Ultrasound-Guided Aspiration of Pelvic Abscesses

    Directory of Open Access Journals (Sweden)

    P. J. Corsi

    1999-01-01

    Full Text Available Objective: To assess the utility of a less invasive approach to the care of women with a pelvic abscess, we retrospectively reviewed the outcome of women with pelvic abscesses managed by transvaginal ultrasound-guided aspiration.

  5. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    Science.gov (United States)

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  6. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  7. Ultrasound in evaluating ovarian reserve

    Directory of Open Access Journals (Sweden)

    Eman Ahmaed Shawky Sabek

    2015-12-01

    Full Text Available The objective of this study was to compare the diagnostic accuracy of transvaginal ultrasound (TVS, as a less invasive technique instead of hormonal assay to evaluate the ovarian reserve. This study included fifty-five females with breast cancer and we compared the ovarian reserve for these patients by hormonal assay through measuring the serum AntiMullerian Hormone (AMH level and follicular stimulating hormone (FSH level before and after chemotherapy, and by transvaginal ultrasound through the ovarian volume (OV calculation and counting the Antral follicles (AFC before and after chemotherapy treatment. There was decline in the AntiMullerian Hormone level after chemotherapy by 27 ± 11.19% and decrease in the Antral follicle counts by 21 ± 13.43%. In conclusion there was strong relation between AMH level and AFC which makes the use of transvaginal ultrasound is a reliable alternative method to the hormonal assay to detect the ovarian reserve.

  8. Transvaginal ultrasound examination of women with and without pelvic venous congestion

    International Nuclear Information System (INIS)

    Halligan, Steve; Campbell, Deidre; Bartram, Clive I.; Rogers, Vera; El-Haddad, Cadria; Patel, Sujata; Beard, Richard W.

    2000-01-01

    AIM: To determine if transvaginal ultrasound, including power Doppler examination, can distinguish between women with and without pelvic congestion. MATERIALS AND METHODS: Thirty-six women with pelvic congestion were prospectively examined using transvaginal ultrasonography and standard uterine and ovarian measurements made. Additionally, planimetric measurements of each ovary were taken using an image analysis program to determine the cross-sectional area of ovarian stroma and follicles, if any. Power Doppler images of adnexal vessels were obtained and planimetric estimates of surface area calculated. A congestion score was assigned to each patient, based on vein number, diameter and morphology on grey-scale scanning. Identical measurements were obtained from 19 asymptomatic women and results compared. RESULTS: There was no significant difference between women with pelvic congestion and controls with respect to power Doppler or grey-scale images of adnexal vessels, or congestion score. However, women with pelvic congestion had significantly larger and multicystic ovaries when compared to controls. CONCLUSIONS: Transvaginal ultrasound measurements of adnexal vasculature, including power Doppler measurements, cannot reliably distinguish women with pelvic congestion from controls. However, ultrasound may remain useful for diagnosis of pelvic congestion, predominantly because it is able to visualize multi-cystic ovaries in these patients. Halligan, S. (2000).Clinical Radiology 55 , 954-958

  9. Annual surveillance by CA125 and transvaginal ultrasound for ovarian cancer in both high-risk and population risk women is ineffective

    DEFF Research Database (Denmark)

    Woodward, E R; Sleightholme, H V; Considine, A M

    2007-01-01

    OBJECTIVE: To assess the efficacy of annual CA125 and transvaginal ultrasound (TVU) scan as surveillance for ovarian cancer. DESIGN: Retrospective audit. SETTING: NHS Trust. POPULATION: Three hundred and forty-one asymptomatic women enrolled for ovarian cancer screening: 179 were in a high...... and local cancer registry data. MAIN OUTCOME MEASURES: Ovarian cancers occurring in study population. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TVU, and CA125 as a screening tool for ovarian cancer. RESULTS: Four ovarian cancers and one endometrial...... cancer occurred. One ovarian cancer was detected at surveillance, three occurred in women who presented symptomatically between screenings. Thirty women underwent exploratory surgery because of abnormal findings at surveillance. Two women had cancer (PPV = 6.7%); one had ovarian cancer and the other...

  10. Flurbiprofen Axetil Provides Effective Analgesia Without Changing the Pregnancy Rate in Ultrasound-Guided Transvaginal Oocyte Retrieval: A Double-Blind Randomized Controlled Trial.

    Science.gov (United States)

    Zhao, Hong; Feng, Yi; Jiang, Yan; Lu, Qun

    2017-10-01

    In this prospective double-blind randomized study, we evaluated the analgesic effect and potential effect on pregnancy rate of the nonsteroidal anti-inflammatory drug flurbiprofen axetil in patients undergoing ultrasound-guided transvaginal oocyte retrieval under propofol-remifentanil anesthesia. A total of 200 patients scheduled to undergo ultrasound-guided transvaginal oocyte retrieval were randomly allocated to receive 1.5 mg/kg of flurbiprofen axetil (FA group) or placebo (control group) 30 minutes before the procedure. Postoperative pain scores, embryo implantation rate, and pregnancy rate were recorded. Neuroendocrine biomarkers and prostaglandin E2 levels in follicular fluid were tested after oocyte retrieval. Patients in the FA group awakened earlier after surgery than patients in the control group (3.3 ± 2.6 vs 5.3 ± 3.4 minutes, P Flurbiprofen axetil given before ultrasound-guided transvaginal oocyte retrieval for patients under propofol-remifentanil general anesthesia relieves pain without any detrimental effect on clinical pregnancy rate.

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  12. Confirmation of Essure placement using transvaginal ultrasound.

    Science.gov (United States)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent hysteroscopic sterilization using the Essure device between March 2005 and December 2007. Transvaginal ultrasound examination 12 weeks after uncomplicated successful bilateral placement or as indicated according to the transvaginal ultrasound protocol after 4 weeks, and hysterosalpingography (HSG) at 12 weeks to confirm correct placement of the device after 3 months. The rate of successful placement was 88.4% initially. In 164 women (15%), successful placement was confirmed at HSG according the protocol. In 9 patients (0.84%), incorrect position of the device was observed at HSG. The cumulative pregnancy rate after 18 months was 3.85 per thousand women. Transvaginal ultrasound should be the first diagnostic test used to confirm the adequacy of hysteroscopic Essure sterilization because it is minimally invasive, averts ionizing radiation, and does not decrease the effectiveness of the Essure procedure. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Impact of transvaginal hydrolaparoscopy ovarian drilling on ovarian stromal blood flow and ovarian volume in clomiphene citrate-resistant PCOS patients: a case-control study.

    Science.gov (United States)

    Giampaolino, Pierluigi; Morra, Ilaria; De Rosa, Nicoletta; Cagnacci, Angelo; Pellicano, Massimiliano; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe

    2017-09-01

    Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder in gynecology. In PCOS patients vascularization parameters are altered. Transvaginal hydrolaparoscopy (THL) is a mini-invasive approach for ovarian drilling in PCOS patients. In this study, we assessed the effect of ovarian drilling using THL on ovarian volume (OV) and vascularization index (VI) using 3D power Doppler ultrasonography in CC-resistant PCOS patients. A case-control study on 123 CC-resistant PCOS women who underwent THL ovarian drilling was performed. Patients underwent 3D ultrasound and power Doppler to measure VI, flow index (FI), vascularization flow index (VFI) and to evaluate OV before and after the procedure, at six months, and on the early follicular phase of the menstrual cycle. After THL ovarian drilling, OV and power Doppler flow indices were significantly reduced compared to pre-operative values (OV: 7.85 versus 11.72 cm 3 , p drilling seems to reduce OV and 3D power Doppler indices, and could therefore be a viable alternative to LOD in PCOS patients resistant to medical therapy.

  14. Acrania/encephalocele sequence (exencephaly) associated with 92,XXXX karyotype: early prenatal diagnosis at 9(+5) weeks by 3D transvaginal ultrasound and coelocentesis.

    Science.gov (United States)

    Tonni, Gabriele; Ventura, Alessandro; Bonasoni, Maria Paola

    2009-09-01

    A 27-year-old pregnant woman was diagnosed by 3D transvaginal ultrasound as carrying a fetus of 9(+5) weeks gestation affected by acrania/encephalocele (exencephaly) sequence. A 2D transvaginal ultrasound-guided aspiration of 5 mL of extra-coelomic fluid was performed under cervical block before uterine suction. Conventional cytogenetic analysis demonstrated a 92,XXXX karyotype. Transvaginal 2D ultrasound-guided coelocentesis for rapid karyotyping can be proposed to women who are near to miscarriage or in cases where a prenatal ultrasound diagnosis of congenital anomaly is performed at an early stage of development. Genetic analysis can be performed using traditional cytogenetic analysis or can be aided by fluorescence in situ hybridization (FISH). Coelocentesis may become an integral part of first trimester armamentarium and may be clinically useful in the understanding of the pathogenesis of early prenatally diagnosed congenital anomalies.

  15. Transvaginal ultrasound appearances of the ovary in normal women and hirsute women with oligomenorrhoea.

    Science.gov (United States)

    Fox, R

    1999-02-01

    The transvaginal ultrasound appearances of the ovary were determined in women with clinical and endocrine features of polycystic ovarian disease (PCOD) and apparently normal women. At scan the number of small follicles were counted and ovarian volume was calculated. The maximum width of the ovarian cortex was also measured. Blood was sent for measurement of LH, FSH and testosterone. The women with oligomenorrhoea were scanned at random and the normal women were seen within the first 5 days of the start of menstruation. There were significant differences between median values for the 2 groups in terms of number of small follicles, ovarian volume and stromal width; the ovaries of the hirsute women had more follicles, were of larger volume, and had greater stromal width. The 2 ranges for number of follicles did overlap, however. Four hirsute oligomenorrhoeic women had a normal number of follicles; all 4 had the several clinical and endocrine features indicative of PCOD. These data suggest that the classical ultrasound features of PCOD are not consistently present and that the absence of increased follicularity at scan should not necessarily deter clinicians from making the functional diagnosis of PCOD.

  16. Transvaginal Ultrasound for the Diagnosis of Abnormal Uterine Bleeding.

    Science.gov (United States)

    Wheeler, Karen C; Goldstein, Steven R

    2017-03-01

    Transvaginal ultrasound is the first-line imaging test for the evaluation of abnormal uterine bleeding in both premenopausal and postmenopausal women. Transvaginal ultrasound can be used to diagnose structural causes of abnormal bleeding such as polyps, adenomyosis, leiomyomas, hyperplasia, and malignancy, and can also be beneficial in making the diagnosis of ovulatory dysfunction. Traditional 2-dimensional imaging is often enhanced by the addition of 3-dimension imaging with coronal reconstruction and saline infusion sonohysterography. In this article we discuss specific ultrasound findings and technical considerations useful in the diagnosis of abnormal uterine bleeding.

  17. Transvaginal ultrasound in threatened abortions with empty gestational sacs.

    Science.gov (United States)

    Tongsong, T; Wanapirak, C; Srisomboon, J; Sirichotiyakul, S; Polsrisuthikul, T; Pongsatha, S

    1994-09-01

    To determine whether transvaginal ultrasound criteria alone can distinguish viable from non-viable gestational sacs at a single examination. A prospective descriptive study was undertaken and analysis performed on 211 pregnancies complicated by threatened abortion and empty gestation sacs diagnosed by transvaginal ultrasound. The main outcome measure was the final diagnosis of viable or non-viable gestation on subsequent transvaginal sonography. The study shows that a single transvaginal ultrasound examination is useful in differentiating viable from non-viable gestation sacs. The mean sac diameter (MSD) was found to be the most useful criterion for determining non-viability. An MSD of > or = 17 mm that lacked an embryo and an MSD of > or = 13 mm without visible yolk sac were reliable predictors of non-viable gestation sacs at a single examination with 100% specificity and 100% positive predictive value. An MSD > or = 13 mm without visible yolk sac was the most sensitive criterion. Using MSD criteria, 73% of non-viable gestations could be reliably identified without any false-positive diagnoses. Deformed shape, low position and thin decidual reaction are strong indicators of non-viable gestations but are not 100% accurate. There is still a significant proportion of empty sacs, where no accurate distinction between viable and non-viable can be made according to one criterion at a single examination and in these cases serial examinations should be carried out before any active management is advocated. In most cases, transvaginal sonographic criteria alone can distinguish viable from non-viable empty gestational sacs at a single examination.

  18. Transvaginal ultrasound during pregnancy: Perception and ...

    African Journals Online (AJOL)

    With the use of high‑resolution transducers, the transvaginal probe has proved to be particularly useful for finding the location and dating of early pregnancies when compared with transabdominal sonography ... Majority (410; 96.7%) had heard about ultrasound scanning, and 395 (93.2%) had undergone at least one type.

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  20. Confirmation of Essure placement using transvaginal ultrasound

    NARCIS (Netherlands)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent

  1. Emergency Department Patient Perceptions of Transvaginal Ultrasound for Complications of First-Trimester Pregnancy.

    Science.gov (United States)

    Panebianco, Nova; Shofer, Frances; O'Conor, Katie; Wihbey, Tristan; Mulugeta, Lakeisha; Baston, Cameron M; Suzuki, Evan; Alghamdi, Adel; Dean, Anthony

    2018-01-30

    Emergency department (ED) transvaginal ultrasound (US) is underused in clinical practice. This study assessed pregnant women's perceptions of ED transvaginal US in terms of pain, embarrassment, anxiety, and willingness to receive the procedure. Secondary variables include physicians' perceptions of patients' experiences. Women undergoing US examinations for complications of first-trimester pregnancy were prospectively surveyed before any US and after ED and/or radiology transvaginal US. Patients' and physicians' assessments of pain, embarrassment, and anxiety were measured with visual analog scales (0-100). A total of 398 women were enrolled. In the pre-US survey, the median anxiety score was 14 (interquartile range, 3-51), and 96% of patients were willing to have an ED transvaginal US if necessary. Of those who had ED transvaginal US, 96% would agree to have another examination. Patients reported minimal pain/embarrassment, and there was no difference if performed in the ED versus radiology (median pain, 11.5 versus 13; P = .433; median embarrassment, 7 versus 4; P = .345). Of the 48 who had both ED and radiology transvaginal US, 85% thought the ED transvaginal US was worthwhile. Physicians accurately assessed patient's embarrassment and pain (mean differences, 3.5 and -1.9, respectively; P > .25 for both); however, they overestimated them relative to the pelvic examination (mean difference for embarrassment, 12.8; P < .0001; pain, 8.0; P = .01). Pregnant ED patients report low levels of anxiety, pain, and embarrassment, and after ED transvaginal US, 96% would agree to have the examination again. There is no difference in pain/embarrassment between ED and radiology transvaginal US. Emergency department physicians accurately assessed patients' pain and embarrassment with ED transvaginal US but overestimated them compared to the pelvic examination. © 2018 by the American Institute of Ultrasound in Medicine.

  2. Rambam Hospital is the Birthplace of the Modern Version of Transvaginal Ultrasound

    Directory of Open Access Journals (Sweden)

    Ilan E. Timor-Tritsch

    2017-04-01

    Full Text Available The worldwide use of the transvaginal scanning route has revolutionized obstetrical and gynecologic imaging. The long, slow, and at times challenging aspects of its acceptance by the obstetrical and gynecologic community are the subject of this article. From its inception to its recent use, the dedicated doctors in the Department of Obstetrics and Gynecology at Rambam Medical Center, Haifa, Israel, were instrumental in conceiving and then collaborating with an Israeli manufacturer in the construction and worldwide use of the transvaginal ultrasound probe, resulting in the now well-known field of transvaginal sonography.

  3. Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.

    Science.gov (United States)

    Ching, Kevin C; Sumkin, Jules H

    2015-01-01

    Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.

  4. Effect of ovarian dermoid cyst excision on ovarian reserve and response: Insights from in vitro fertilization

    OpenAIRE

    Lei Yan; Miao Li; Bing-Qian Zhang; Xin-Xin Xu; Zhen Xu; Ting Han; Zi-Jiang Chen

    2016-01-01

    Study objective: To investigate the impact of an ovarian dermoid cyst or dermoid cyst surgery on ovarian reserve in patients undergoing in vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI). Design: We performed a retrospective cohort study by using the records of patients with a history of ovarian dermoid cyst who underwent IVF/ICSI between 2009 and 2013. The antral follicle count (AFC) obtained by transvaginal ultrasound during controlled ovarian hyperstimulation of IVF/ICSI...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  6. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  7. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  8. Ovarian reserve in fertile women as determined by ultrasonography

    International Nuclear Information System (INIS)

    Usmani, A.; Shokh, I.S.

    2007-01-01

    To determine ovarian reserve in naturally fertile adult women. Healthy fertile females (n = 70) aged 20-39 years with proven natural fertility were recruited between March and December 2006. Of these, 40 met the inclusion criteria. Total ovarian volume was calculated using the transabdominal and transvaginal ultrasound approach and an antral follicle count was perfonned transvaginally. The height and weight of each individual was taken to calculate the BMI, and the correlation made between ovarian volume (determined transvaginally) and the BMI. The women were divided into 2 groups of 20 each viz. between 20 -29 years, and between 30 - 39 years. Total ovarian volume detennined by transabdominal scan was 13 +- 3.46 ml and 7.92+-2.0 ml respectively in the two groups, and by transvaginal route was 15.13 +- 4.37 ml and 9.97 +- 2.99 ml respectively (p-value of both was 0.001). The AFC was 9.40 +- 2.37and 5.3 +- 2.05 in the two groups (p-value 0.001). The BMI of the 2 groups was 23.4 +- 3.97 and 24.4 +- 3.8 (p-value 0.421). The correlation between ovarian volume and BMI was -0.40 (p-value 0.05). Ovarian volume and antral follicle count were reduced significantly in the older age group; there was no difference between the BMI of the two age groups. When BMI of all women was plotted against ovarian volume, a decrease in the ovarian volume was observed with an increase in BMI. (author)

  9. Transvaginal sonography of acute pelvic inflammatory disease

    International Nuclear Information System (INIS)

    Choi, Jin Soo; Kim, Young Hwa; Shin, Hyung Chul; Han, Gun Soo; Kim, Il Young

    1999-01-01

    To determine the value of transvaginal sonography in evaluating women with acute pelvic inflammatory disease (PID). Transvaginal sonography was performed in 25 patients with clinically suggested PID during recent 36 months. The sonographic findings of fallopian tubes and ovaries were analyzed and correlated with pathological findings of 2 fallopian tubes and 19 ovaries in 16 patients who had operations. The correct diagnosis of acute PID was made in 20/25 (80%) by transvaginal sonography. the abnormal sonographic findings of the fallopian tube include tubal thickening or dilatation with internal echo. The sensitivity, specificity, and accuracy for tubal abnormality were 88%, 96%, and 86% , respectively. Ovarian changes were seen on TVS in 14/19 (73%), which include multiple follicular enlargement in 5, tubo-ovarian complex in 9 (tubo-ovarian adhesion in 3, tubo-ovarian abscess in 6). At surgery, the ovay was not involved in all three women who showed tubo-ovarian adhesion on TVS. Among 6 women who showed tubo-ovarian abscess on TVS, tubo-ovarian abscess was confirmed in 3 and the remaining 3 had ovarian cysts. Trandvaginal sonography, a facilitative and accurate modality, is highly sensitive in detecting the abnormality of the tube and useful in differentiating the tubo-ovarian complex in patients with acute PID.

  10. Assessment of performance measures and learning curves for use of a virtual-reality ultrasound simulator in transvaginal ultrasound examination

    DEFF Research Database (Denmark)

    Madsen, M E; Konge, L; Nørgaard, L N

    2014-01-01

    OBJECTIVE: To assess the validity and reliability of performance measures, develop credible performance standards and explore learning curves for a virtual-reality simulator designed for transvaginal gynecological ultrasound examination. METHODS: A group of 16 ultrasound novices, along with a group......-6), corresponding to an average of 219 min (range, 150-251 min) of training. The test/retest reliability was high, with an intraclass correlation coefficient of 0.93. CONCLUSIONS: Competence in the performance of gynecological ultrasound examination can be assessed in a valid and reliable way using virtual-reality...

  11. Evaluation of pelvic varicose veins using color Doppler ultrasound: comparison of results obtained with ultrasound of the lower limbs, transvaginal ultrasound, and phlebography Avaliação de varizes pélvicas por Doppler colorido: comparação dos resultados obtidos com ultrassom dos membros inferiores, ultrassom transvaginal e flebografia

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2010-06-01

    Full Text Available Introduction: Pelvic varicose veins, one of the main causes of chronic pelvic pain and dyspareunia, are an important source of reflux for lower limb varicose veins, especially in recurrent cases. Color Doppler ultrasound of the lower limbs and transvaginal ultrasound are the noninvasive diagnostic methods most commonly used to assess pelvic venous insufficiency, whereas phlebography is still considered as the gold standard. Objectives: To determine the prevalence of lower limb varicose veins originating from the pelvis in a group of female patients and to determine the agreement between results obtained via color Doppler ultrasound of the lower limbs, transvaginal ultrasound, and phlebography. Methods: The sample comprised female patients referred to a vascular laboratory for lower limb screening. Patients diagnosed with deep venous thrombosis were excluded. Data analysis included kappa coefficient of agreement, McNemar's test, sensitivity and specificity values. Results: Of a total of 1,020 patients, 124 (12.2% had findings compatible with reflux of pelvic origin. Among these patients, 51 (41.2% were recurrent cases. A total of 249 were submitted to transvaginal ultrasound. There was significant agreement between lower limb ultrasonographic findings and transvaginal findings. Phlebography was performed in 54 patients. The comparison between transvaginal ultrasound and phlebography was associated with a 96.2% sensitivity and 100% specificity. Conclusions: The authors draw attention to the relatively high prevalence of lower limb varicose veins originating from the pelvis, suggesting an important but underdiagnosed cause of recurrent varicose veins.Introdução: AS VARIZES Pélvicas, uma das principais causas de dor pélvica crônica e dispareunia, são uma importante fonte de refluxo para as varizes dos membros inferiores, especialmente em casos recorrentes. O Doppler colorido dos membros inferiores e o ultrassom transvaginal são os m

  12. A proposal to reduce the risk of transmission of human papilloma virus via transvaginal ultrasound.

    Science.gov (United States)

    Combs, C Andrew; Fishman, Alan

    2016-07-01

    Three steps must be followed to prevent the transmission of infection via a contaminated transvaginal ultrasound probe: cleaning the probe after every use, high-level disinfection, and covering the probe with a single-use barrier during the examination. There may be critical flaws in at least 2 of these steps as they are currently practiced. First, 2 widely used disinfectants, glutaraldehyde and orthophthalaldehyde, have recently been found to be ineffective at neutralizing human papilloma virus type 16 and type 18. Second, commercial ultrasound probe covers have an unacceptable rate of leakage (8-81%) compared to condoms (0.9-2%). We recommend the use of a sonicated hydrogen peroxide disinfectant system rather than aldehyde-type disinfectants. We recommend that the probe be covered with a condom rather than a commercial probe cover during transvaginal ultrasound examination. Combined with probe cleaning, these 2 steps are estimated to result in an 800 million- to 250 billion-fold reduction in human papilloma virus viral load, which should translate to greatly enhanced patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Office hysteroscopy, transvaginal ultrasound and endometrial histology: a comparison in infertile patients

    Directory of Open Access Journals (Sweden)

    Devleta Balić

    2011-05-01

    Full Text Available Objective. To evaluate accuracy of transvaginal sonography (TVS and hysteroscopy in detection of intrauterine pathology in infertile women. Subjects and methods. This retrospective study was conducted in 56 infertile women with abnormal transvaginal ultrasound findings of the uterine cavity which was performed during the midfollicular phase as a part of routine infertility workup. Hysteroscopy was performed between 6th and 10th day of cycle. Results. The mean age of the subjects was 31.9±4.0. The most frequent ultrasound finding was endometrial polyp in 34 (60.7% patients, septate uterus in 8 (14.3% patients, submucosal myoma in 7 (12.5% patients, endometrial hyperplasia in 5 (8.9% patients and Syndroma Ascherman in 2 (3.6% patients. Hysteroscopy confirmed 20 (35.7% polyps, the same number of myomas, septate uterus and Syndroma Ascherman as detected by ultrasound, (7 (12.5%, 8 (14.3% and 2 (3.6%, respectively and 19 (33.9% endometrial hyperplasia. In 46 women with histological excamination, the sensitivity of TVS and hysteroscopy in the diagnosis of endometrial polyps were identical - 100%, while the specificity was higher in hysteroscopy than in TVS (92.3% versus 56.4%, p<0.001. The sensitivity of TVS in the diagnosis of endometrial hyperplasia was higher than that of hysteroscopy (86.4% versus 22.7%, p<0.001, while specificity was identical, of 100%. Accordance between hysteroscopy and histology was good (k=0.79, between ultrasound and histology was moderete (k=0.59. Conclusion. Hysteroscopy appeared to be more reliable in diagnosis than TVS. The use of a high frequency ultrasound probe leads us to a lack of diagnostic clarity between endometrial polyps and hyperplasia.

  14. Ovarian morphology in polycystic ovary syndrome: estimates from 2D and 3D ultrasound and magnetic resonance imaging and their correlation to anti-Müllerian hormone.

    Science.gov (United States)

    Nylander, Malin; Frøssing, Signe; Bjerre, Anne H; Chabanova, Elizaveta; Clausen, Helle V; Faber, Jens; Skouby, Sven O

    2017-08-01

    Background Due to improved ultrasound scanners, new three-dimensional (3D) modalities, and novel Anti-Müllerian hormone (AMH)-assays, the ultrasound criteria for polycystic ovarian morphology are under debate and the appropriate thresholds are often requested. Purpose To quantify the differences in estimates of ovarian volume and antral follicle count (AFC) from two-dimensional (2D) and 3D transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI). Material and Methods A cross-sectional study on 66 overweight women with polycystic ovary syndrome (PCOS) according to Rotterdam criteria. Ovarian volume and AFC were estimated from MRI, 2D TVUS, and 3D TVUS, and serum AMH levels were assessed. Bland-Altman statistics were used for comparison. Results Participants had a median age of 29 years (age range, 19-44 years) with a mean BMI of 32.7 kg/m 2 (SD 4.5). Ovarian volume from 2D TVUS was 1.48 mL (95% confidence interval [CI], 0.94-2.03; P ovarian volume and AFC as compared with 3D TVUS and MRI. Serum AMH correlated best with AFC from 3D TVUS, followed by MRI and 2D TVUS. The advantage of 3D TVUS might be of minor clinical importance when diagnosing PCOS, but useful when the actual AFC are of interest, e.g. in fertility counseling and research.

  15. Transvaginal ultrasound assessment of myometrial and cervical stroma invasion in women with endometrial cancer -interobserver reproducibility among ultrasound experts and gynaecologists

    DEFF Research Database (Denmark)

    Eriksson, LS; Lindqvist, PG; Flöter Rådestad, A

    2014-01-01

    OBJECTIVES: To assess interobserver reproducibility among ultrasound experts and gynaecologists in the prediction of deep myometrial- and cervical stroma invasion by transvaginal ultrasound in women with endometrial cancer. METHODS: Video-clips of the corpus- and cervix uteri of 53 women...... with endometrial cancer, examined preoperatively by the same ultrasound expert, were integrated in a digitalized survey. Nine ultrasound experts and 9 gynaecologists evaluated presence or absence of deep myometrial- and cervical stroma invasion. Histopathology from hysterectomy specimen was used as gold standard.......001). CONCLUSION: Preoperative ultrasound assessment of deep myometrial- and cervical stroma invasion in endometrial cancer is best performed by ultrasound experts, as they show a higher degree of agreement to histopathology and higher interobserver reproducibility in the assessment of cervical stromal invasion....

  16. Dual-mode photoacoustic and ultrasound system for real-time in-vivo ovarian cancer imaging

    Science.gov (United States)

    Mostafa, Atahar; Nandy, Sreyankar; Amidi, Eghbal; Zhu, Quing

    2018-02-01

    More than 80% of the ovarian cancers are diagnosed at late stages and the survival rate is less than 50%. Currently, there is no effective screening technique available and transvaginal US can only tell if the ovaries are enlarged or not. We have developed a new real-time co-registered US and photoacoustic system for in vivo imaging and characterization of ovaries. US is used to localize ovaries and photoacoustic imaging provides functional information about ovarian tissue angiogenesis and oxygenation saturation. The system consists of a tunable laser and a commercial US system from Alpinion Inc. The Alpinion system is cable of providing channel data for both US pulse-echo and photoacoustic imaging and can be programmed as a computer terminal for display US and photoacoustic images side by side or in coregistered mode. A transvaginal ultrasound probe of 6-MHz center frequency and bandwidth of 3-10 MHz is coupled with four optical fibers surrounded the US probe to deliver the light to tissue. The light from optical fibers is homogenized to ensure the power delivered to the tissue surface is below the FDA required limit. Physicians can easily navigate the probe and use US to look for ovaries and then turn on photoacoustic mode to provide real-time tumor vasculature and So2 saturation maps. With the optimized system, we have successfully imaged first group of 7 patients of malignant, abnormal and benign ovaries. The results have shown that both photoacoustic signal strength and spatial distribution are different between malignant and abnormal and benign ovaries.

  17. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    International Nuclear Information System (INIS)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J.

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome

  18. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome.

  19. Outcomes of trocar-guided Gynemesh PS™ versus single-incision trocarless Polyform™ transvaginal mesh procedures.

    Science.gov (United States)

    Larouche, Maryse; Merovitz, Lisa; Correa, José A; Walter, Jens-Erik

    2015-01-01

    The aim of the study was to compare rates of success, mesh exposure, and surgical re-intervention after trocar-guided Gynemesh PS™ and trocarless Polyform™ transvaginal mesh procedures. We conducted a retrospective cohort study of all transvaginal mesh procedures performed at our centers between January 2008 and May 2012. Multiple logistic regression models were used to explore the binary outcomes of objective and subjective success rates, as well as mesh exposure and re-intervention rates, between the two procedures after adjustment for patient's age, parity, body mass index, smoking status, previous hysterectomy, previous prolapse surgery, and follow-up time. We included 103 transvaginal mesh procedures (47 trocar-guided Gynemesh PS™ and 56 trocarless Polyform™). In both groups, Pelvic Organ Prolapse Quantification (POP-Q) scores were significantly improved after the procedure. Median follow-up was 340 days and interquartile range (IQR) 152-644. Objective success rates were 55.3 % (26/47) in the trocar group and 60.7 % (34/56) in the trocarless group (p = 0.9), whereas subjective success was 83.0 % (39/47) and 94.6 % (53/56), respectively (p = 0.1). The adjusted odds of developing mesh exposure were significantly less after trocarless transvaginal mesh procedures compared to trocar-guided ones [odds ratio (OR) 0.16, 95 % confidence interval (CI) 0.03-0.97]. Surgical re-interventions, aimed mostly at treating recurrent prolapse, mesh exposure, and latent stress urinary incontinence, were also significantly less frequent after trocarless procedures [5 patients (8.9 %) requiring re-intervention versus 15 (31.9 %), respectively, adjusted OR 0.15, 95 % CI 0.04-0.60]. Trocar-guided Gynemesh PS™ and trocarless Polyform™ transvaginal mesh systems result in similar objective and subjective success rates. The newer Polyform™ mesh results in significantly fewer mesh exposures and surgical re-interventions.

  20. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    Science.gov (United States)

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. The Effects of Simulation-based Transvaginal Ultrasound Training on Quality and Efficiency of Care

    DEFF Research Database (Denmark)

    Tolsgaard, Martin Grønnebæk; Ringsted, Charlotte; Rosthøj, Susanne

    2017-01-01

    , but no studies have examined its effects on quality and efficiency of care. METHODS: Trainees from 4 University Hospitals in East Denmark were included (N = 54). Participants were randomized to either simulation-based ultrasound training and clinical training (intervention group, n = 28), or to clinical training......, 33.5-55.1) and 19.8% (95% CI, 4.1-32.9) in the intervention and control group, respectively (P = 0.005). CONCLUSIONS: Simulation-based ultrasound training improved quality of care and reduced the need for repeated patient examination and trainee supervision.......OBJECTIVE: To explore the effect of adding simulation-based transvaginal ultrasound training to trainees' clinical training compared with only clinical training on quality of and efficiency of care. BACKGROUND: Simulation-based ultrasound training may be an effective adjunct to clinical training...

  2. Sonographic features of tubo-ovarian abscess mimicking an endometrioma and review of cystic adnexal masses

    OpenAIRE

    Velcani, Artur; Conklin, Patrick; Specht, Neil

    2010-01-01

    A 36-year-old female presented with constant, worsening left lower quadrant pain without associated fever or vaginal discharge. Pelvic and transvaginal ultrasound examinations were performed which demonstrated a large complex cystic structure in the left adnexa with peripheral flow on color Doppler imaging. Given the sonographic appearance and patient symptoms, possibilities included endometrioma or hemorrhagic cyst. Tubo-ovarian abscess (TOA) and other cystic ovarian masses were considered l...

  3. Ovarian volume and antral follicle count assessed by MRI and transvaginal ultrasonography: a methodological study.

    Science.gov (United States)

    Leonhardt, Henrik; Gull, Berit; Stener-Victorin, Elisabet; Hellström, Mikael

    2014-03-01

    Ultrasonographic measurements of ovarian volume and antral follicle count are of clinical importance as diagnostic features of polycystic ovarian syndrome (PCOS), and as a parameter in estimation of ovarian follicular reserve in infertility care. To compare two-dimensional (2D)/three-dimensional (3D) transvaginal ultrasonography (TVUS) and magnetic resonance imaging (MRI) for estimation of ovarian volume and antral follicle count, and to assess reproducibility and inter-observer agreement of MRI measurements. Volumes of 172 ovaries in 99 women aged 21-37 years were calculated (length x width x height x 0.523) with conventional 2D TVUS and 2D MRI. Semi-automatic estimates of ovarian volumes were obtained by 3D MRI. Antral follicles were counted manually on 2D MRI and automatically by 3D TVUS (SonoAVC), and stratified according to follicle size. Mean ovarian volume assessed by 2D TVUS (13.1 ± 6.4 mL) was larger than assessed by 2D MRI (9.6 ± 4.1) and 3D MRI (11.4 ± 4.5) (P 0.77. 2D MRI reveals more antral follicles, especially of small size, than 3D TVUS. Ovarian volume estimation by MRI provides smaller volumes than by the reference standard 2D TVUS. Ovarian volume estimation by 3D MRI, allowing independence of non-ellipsoid ovarian shape measurement errors, provides volumes closer to 2D TVUS values than does 2D MRI. Reproducibility and inter-observer agreement of 2D MRI measurements of ovarian volume and total follicle count are good.

  4. Interlaced photoacoustic and ultrasound imaging system with real-time coregistration for ovarian tissue characterization

    Science.gov (United States)

    Alqasemi, Umar; Li, Hai; Yuan, Guangqian; Kumavor, Patrick; Zanganeh, Saeid; Zhu, Quing

    2014-07-01

    Coregistered ultrasound (US) and photoacoustic imaging are emerging techniques for mapping the echogenic anatomical structure of tissue and its corresponding optical absorption. We report a 128-channel imaging system with real-time coregistration of the two modalities, which provides up to 15 coregistered frames per second limited by the laser pulse repetition rate. In addition, the system integrates a compact transvaginal imaging probe with a custom-designed fiber optic assembly for in vivo detection and characterization of human ovarian tissue. We present the coregistered US and photoacoustic imaging system structure, the optimal design of the PC interfacing software, and the reconfigurable field programmable gate array operation and optimization. Phantom experiments of system lateral resolution and axial sensitivity evaluation, examples of the real-time scanning of a tumor-bearing mouse, and ex vivo human ovaries studies are demonstrated.

  5. Necrotising fasciitis after hysterectomy and concomitant transvaginal mesh repair in a patient with pelvic organ prolapse.

    Science.gov (United States)

    Pushkar, Dmitry Y; Vasilchenko, Mikhail I; Kasyan, George R

    2013-10-01

    Necrotising fasciitis is a severe form of soft tissue infection. Herein, we present an unreported complication of the transvaginal repair of a pelvic organ prolapse (POP) with trocar-guided polypropylene mesh and a concomitant hysterectomy. A 61-year-old Caucasian female who had been using an intrauterine device (IUD) for 30 years presented with a stage 3 pelvic organ prolapse. A genital ultrasound examination confirmed the presence of an IUD, but found no endometrial abnormalities. The surgical management was limited to a transvaginal hysterectomy and simultaneous anterior vaginal wall repair augmented with trocar-guided mesh. A morphological examination of the removed uterus confirmed the presence of the intrauterine device and additionally found endometrial cancer (T1N0M0), which was not revealed during the preoperative ultrasound. Within 6 days of the surgery, she developed anaerobic bilateral necrotising fasciitis on both thighs. Non-clostridial streptococci were identified in the wound. After 18 days of intensive care, the patient died of fatal coagulopathy.

  6. Ultrasound study of ovarian pain in pre adolescent and adolescent girls

    International Nuclear Information System (INIS)

    Sanguesa, C.; Muro, D.

    1999-01-01

    To assess the role of ultrasound in the study of acute ovarian pain in pre adolescent and adolescent girls. B-mode ultrasound was employed to study 40 ovarian lesions in 37 girls between the age of 6 and 17 years complaining of acute pelvic pain of ovarian origin. Thirteen of the lesions were also assessed by color Doppler ultrasound. We found 25 cases of hemorrhagic cysts, 8 of simple cyst and 7 of ovarian torsion. Surgical and pathological correlation was established in 17 cases (7 cases hemorrhagic cyst, 3 of simple cysts and 7 of ovarian torsion). The remaining lesions are being followed by clinical and ultrasonographic monitoring. Simple and hemorrhagic cysts presenting the so called hematocrit effect are easily diagnosed by B-mode ultrasound. The ultrasonographic features of torsion and certain hemorrhagic cysts are similar on occasion, and surgery and histologic assessment are necessary for the definitive diagnosis. Doppler ultrasound provides no additional information to aid in the diagnosis of these lesions. (Author) 28 refs

  7. Transvaginal duplex ultrasonography appears to be the gold standard investigation for the haemodynamic evaluation of pelvic venous reflux in the ovarian and internal iliac veins in women.

    Science.gov (United States)

    Whiteley, M S; Dos Santos, S J; Harrison, C C; Holdstock, J M; Lopez, A J

    2015-12-01

    To assess the suitability of transvaginal duplex ultrasonography to identify pathological reflux in the ovarian and internal iliac veins in women. A retrospective study of patients treated in 2011 and 2012 was performed in a specialised vein clinic. Diagnostic transvaginal duplex ultrasonography in women presenting with symptoms or signs of pelvic vein reflux were compared with the outcomes of treatment from pelvic vein embolisation. A repeat transvaginal duplex ultrasonography was performed 6 weeks later by a blinded observer and any residual reflux was identified. Results from 100 sequential patients were analysed. Mean age 44.2 years (32-69) with mode average parity of 3 (0-5 deliveries). Pre-treatment, 289/400 veins were refluxing (ovarian - 29 right, 81 left; internal iliac - 93 right, 86 left). Coil embolisation was successful in 86/100 patients and failed partially in 14/100 - 5 due to failure to cannulate the target vein. One false-positive diagnosis was made. Currently there is no accepted gold standard for pelvic vein incompetence. Comparing transvaginal duplex ultrasonography with the outcome from selectively treating the veins identified as having pathological reflux with coil embolisation, there were no false-negative diagnoses and only one false-positive. This study suggests that transvaginal duplex ultrasonography could be the gold standard in assessing pelvic vein reflux. © The Author(s) 2014.

  8. Randomized Clinical Trial of Virtual Reality Simulation Training for Transvaginal Gynecologic Ultrasound Skills.

    Science.gov (United States)

    Chao, Coline; Chalouhi, Gihad E; Bouhanna, Philippe; Ville, Yves; Dommergues, Marc

    2015-09-01

    To compare the impact of virtual reality simulation training and theoretical teaching on the ability of inexperienced trainees to produce adequate virtual transvaginal ultrasound images. We conducted a randomized controlled trial with parallel groups. Participants included inexperienced residents starting a training program in Paris. The intervention consisted of 40 minutes of virtual reality simulation training using a haptic transvaginal simulator versus 40 minutes of conventional teaching including a conference with slides and videos and answers to the students' questions. The outcome was a 19-point image quality score calculated from a set of 4 images (sagittal and coronal views of the uterus and left and right ovaries) produced by trainees immediately after the intervention, using the same simulator on which a new virtual patient had been uploaded. Experts assessed the outcome on stored images, presented in a random order, 2 months after the trial was completed. They were blinded to group assignment. The hypothesis was an improved outcome in the intervention group. Randomization was 1 to 1. The mean score was significantly greater in the simulation group (n = 16; mean score, 12; SEM, 0.8) than the control group (n = 18; mean score, 9; SEM, 1.0; P= .0302). The quality of virtual vaginal images produced by inexperienced trainees was greater immediately after a single virtual reality simulation training session than after a single theoretical teaching session. © 2015 by the American Institute of Ultrasound in Medicine.

  9. Ovarian morphology in polycystic ovary syndrome

    DEFF Research Database (Denmark)

    Nylander, Malin; Frøssing, Signe; Bjerre, Anne H.

    2017-01-01

    in estimates of ovarian volume and antral follicle count (AFC) from two-dimensional (2D) and 3D transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI). Material and Methods A cross-sectional study on 66 overweight women with polycystic ovary syndrome (PCOS) according to Rotterdam criteria. Ovarian...... between AMH and AFC from 2D TVUS, 3D TVUS, and MRI were 0.67, 0.78, and 0.70, respectively (P PCOS population, 2D TVUS underestimated ovarian volume and AFC as compared with 3D TVUS and MRI. Serum AMH correlated best with AFC from 3D TVUS, followed by MRI...... and 2D TVUS. The advantage of 3D TVUS might be of minor clinical importance when diagnosing PCOS, but useful when the actual AFC are of interest, e.g. in fertility counseling and research....

  10. Toward in-vivo photoacoustic imaging of human ovarian tissue for cancer detection

    Science.gov (United States)

    Aguirre, Andres; Kumavor, Patrick; Ardeshirpour, Yasaman; Sanders, Mary M.; Brewer, Molly; Zhu, Quing

    2011-03-01

    Currently, most of the cancers in the ovary are detected when they have already metastasized to other parts of the body. As a result, ovarian cancer has the highest mortality of all gynecological cancers with a 5-year survival rate of 30% or less [1]. The reason is the lack of reliable symptoms as well as the lack of efficacious screening techniques [2,3]. Thus, there is an urgent need to improve the current diagnostic techniques. We have investigated the potential role of co-registered photoacoustic and ultrasound imaging in ovarian cancer detection. In an effort to bring this technique closer to clinical application, we have developed a co-registered ultrasound and photoacoustic transvaginal probe. A fiber coupling assembly has been developed to deliver the light from around the transducer for reflection geometry imaging. Co-registered ultrasound and photoacoustic images of swine ovaries through vagina wall muscle and human ovaries using the aforementioned probe, demonstrate the potential of photoacoustic imaging to non-invasively detect ovarian cancer in vivo.

  11. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  12. Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator.

    Science.gov (United States)

    Khazendar, S; Sayasneh, A; Al-Assam, H; Du, H; Kaijser, J; Ferrara, L; Timmerman, D; Jassim, S; Bourne, T

    2015-01-01

    Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered.

  13. Misdiagnosed Ovarian Pregnancy to Threatened Abortion: A Case Report

    Directory of Open Access Journals (Sweden)

    Roghaieh Rahmani Beilondi

    2017-10-01

    Full Text Available This study is about a patient with a history of infertility and polycystic ovarian disease who was admitted with spotting and severe abdominal pain, There was one misdiagnosis about this patient and progesterone was prescribed for treating of threatened abortion, following transvaginal ultrasound, one heterogeneous echogenic mass with dimensions of 5.8 × 18 in the vicinity of the left ovary was reported in favor of ectopic pregnancy. The patient was hospitalized and treated with methotrexate with diagnosis of an ovarian ectopic pregnancy. Pregnant women with complaints of bleeding and spotting in early pregnancy should be evaluated in terms of ectopic pregnancy in addition of abortion and molar pregnancy. The aim of this study was to introduce a new case of misdiagnosed ovarian pregnancy instead of threatened abortion.

  14. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis

    OpenAIRE

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-01-01

    Objectives The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. Design and setting 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups’ results. Fi...

  15. Effect of antitubercular treatment on ovarian function in female genital tuberculosis with infertility

    Directory of Open Access Journals (Sweden)

    Jai Bhagwan Sharma

    2016-01-01

    Full Text Available AIM: To evaluate the effect of antitubercular therapy (ATT on an ovarian function such as ovarian reserve, ovarian dimensions, and ovarian stromal blood flow. SETTINGS AND DESIGN: Prospective study design. MATERIALS AND METHODS: Fifty infertile women with female genital tuberculosis (FGTB without tubo-ovarian masses diagnosed by positive acid-fast bacilli culture or epithelioid granuloma on endometrial aspirate or positive polymerase chain reaction with positive findings on laparoscopy or hysteroscopy were recruited. The ovarian function tests were performed on day 2/3 as follicle-stimulating hormone (FSH levels and anti-Mullerian hormone (AMH levels. Ovarian dimensions (length, width, and depth were measured using a transvaginal ultrasound. Mean antral follicle count (AFC and ovarian stromal blood flow (peak systolic velocity [PSV], pulsatility index (PI, and resistive index [RI] were measured using a transvaginal ultrasound. All women were started on ATT for 6 months by directly observed treatment strategy. After completion of ATT, all the parameters were repeated. RESULTS: There was a significant increase in AMH (2.68 ± 0.97 ng/ml to 2.8 ± 1.03 ng/ml pre- to post-ATT, nonsignificant increase in FSH (7.16 ± 2.34 mIU/ml to 7.26 ± 2.33 mIU/ml post-ATT, significant increase in mean AFC (7.40 ± 2.12-8.14 ± 2.17, PSV in the right ovary (6.015-6.11 cm/s and left ovary (6.05-6.08 cm/s, PI in the right ovary (0.935-0.951 cm/s and left ovary (0.936-0.957 cm/s, and RI in the right ovary (0.62 ± 0.01-0.79 ± 0.02 and left ovary (0.65 ± 0.02-0.84 ± 0.01 with ATT. There was no significant change in mean ovarian dimensions (ovarian length, breadth, and width and summed ovarian volume with ATT. On laparoscopy, tubercles were seen in 27 (54% women. Caseous nodules and encysted ascites were seen in 8% cases each. CONCLUSION: ATT improves the ovarian function (AMH and AFC and ovarian blood flow in women with FGTB.

  16. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  17. Ovarian capsular drilling in the treatment of clomiphene citrate ...

    African Journals Online (AJOL)

    Background: Laparoscopic Ovarian Drilling (LOD) is an effective and a well evaluated surgical Treatment of Clomiphene Citrate resistant Polycystic ovarian syndrome. Transvaginal hydrolaparoscopy (TVHL) is a relatively new simple method of exploring the pelvis and has recently been introduced as a transvaginal ...

  18. Prediction of polycystic ovarian syndrome based on ultrasound findings and clinical parameters.

    Science.gov (United States)

    Moschos, Elysia; Twickler, Diane M

    2015-03-01

    To determine the accuracy of sonographic-diagnosed polycystic ovaries and clinical parameters in predicting polycystic ovarian syndrome. Medical records and ultrasounds of 151 women with sonographically diagnosed polycystic ovaries were reviewed. Sonographic criteria for polycystic ovaries were based on 2003 Rotterdam European Society of Human Reproduction and Embryology/American Society for Reproductive Medicine guidelines: at least one ovary with 12 or more follicles measuring 2-9 mm and/or increased ovarian volume >10 cm(3) . Clinical variables of age, gravidity, ethnicity, body mass index, and sonographic indication were collected. One hundred thirty-five patients had final outcomes (presence/absence of polycystic ovarian syndrome). Polycystic ovarian syndrome was diagnosed if a patient had at least one other of the following two criteria: oligo/chronic anovulation and/or clinical/biochemical hyperandrogenism. A logistic regression model was constructed using stepwise selection to identify variables significantly associated with polycystic ovarian syndrome (p polycystic ovaries and 115 (89.8%) had polycystic ovarian syndrome (p = .009). Lower gravidity, abnormal bleeding, and body mass index >33 were significant in predicting polycystic ovarian syndrome (receiver operating characteristics curve, c = 0.86). Pain decreased the likelihood of polycystic ovarian syndrome. Polycystic ovaries on ultrasound were sensitive in predicting polycystic ovarian syndrome. Ultrasound, combined with clinical parameters, can be used to generate a predictive index for polycystic ovarian syndrome. © 2014 Wiley Periodicals, Inc.

  19. Prevenção do parto prematuro: emprego do toque vaginal e da ultra-sononografia transvaginal Prevention of preterm birth: use of digital examination and transvaginal ultrasonography

    Directory of Open Access Journals (Sweden)

    Arlete Ayako Yamasaki

    1998-07-01

    Full Text Available Objetivo: avaliar o colo uterino por meio do toque vaginal e da ultra-sonografia transvaginal em gestantes de risco elevado para o parto prematuro. Métodos: durante o período compreendido entre fevereiro de 1995 e setembro de 1997 foram acompanhadas 38 gestantes com elevado risco para o parto prematuro entre a 20ª e 36ª semana de gestação. Estas pacientes foram submetidas semanalmente ao toque vaginal e ao exame ultra-sonográfico transvaginal. O toque vaginal avaliou o colo uterino quanto a dois parâmetros: comprimento e dilatação. A ultra-sonografia transvaginal estudou o comprimento e o diâmetro anteroposterior do colo uterino. Foram analisados os comportamentos destas medidas cervicais ao longo da gestação. Os dois métodos foram comparados quanto à avaliação cervical e à acurácia no diagnóstico do parto prematuro. Resultados: a incidência de partos prematuros foi de 18,4% (7/38. As medidas do comprimento cervical obtidas pela ultra-sonografia foram sempre maiores em relação às medidas obtidas pelo toque vaginal. Mediante análise pelo teste de hipóteses foram observadas uma relação indireta entre o comprimento cervical e a idade gestacional por meio do toque e do estudo ultra-sonográfico (pObjective: to evaluate the uterine cervix by digital and transvaginal ultrasound examinations in pregnant women at high risk of having premature delivery. Methods: during the period between February 1995 and September 1997, 38 pregnant women at high risk of having premature delivery between the 20th and 36th week of gestation were examined. These patients were submitted weekly to both digital and transvaginal ultrasound examinations. The digital examination evaluated the uterine cervix using two parameters: length and dilation. The transvaginal ultrasound studied the length and the anteroposterior diameter of the uterine cervix. The behavior of these cervical measurements was analyzed throughout the pregnancies. The two methods

  20. Age-Related Normogram for Ovarian Antral Follicle Count in Women with Polycystic Ovary Syndrome and Comparison with Age Matched Controls Using Magnetic Resonance Imaging.

    Science.gov (United States)

    Aiyappan, Senthil Kumar; Karpagam, Bulabai; Vadanika, V; Chidambaram, Prem Kumar; Vinayagam, S; Saravanan, K C

    2016-01-01

    Antral Follicle count (AFC) is a reliable marker for ovarian reserve. Previous studies have used transvaginal ultrasound for estimation of AFC, however we used magnetic resonance imaging (MRI) for estimation of AFC and for creating an age-related normogram in patients with polycystic ovary syndrome (PCOS) and compared it with normal patients. The aim of this study is to create an age related normogram for AFC in women with PCOS and to compare that with women without polycystic ovarian syndrome using MRI. A total of 1500 women were examined, out of which 400 fitted the criteria for PCOS. They all underwent MRI study and similar age matched women without PCOS also underwent MRI examination. Normogram for AFC were obtained using LMS software and a percentile chart was obtained. Normogram for AFC in PCOS women showed decline in number of AFC as the age progresses and the decline was linear. The normogram for AFC was compared with equal number of patients without PCOS and they also showed decline in AFC as the age progresses, however the decline was exponential and faster. Age related normogram for AFC is widely used and considered as best clinical predictor for ovarian response in assisted reproductive technology. Knowledge of ovarian reserve is important in PCOS and non-PCOS females as PCOS patients are at risk for ovarian hyperstimulation syndrome during gonadotrophin theraphy. MRI is an equally effective and in some times better alternative to transvaginal ultrasound as it has got its own advantages.

  1. High-resolution ultrasound biomicroscopy for monitoring ovarian structures in mice

    Directory of Open Access Journals (Sweden)

    Singh Jaswant

    2009-07-01

    Full Text Available Abstract Background Until recently, the limit of spatial resolution of ultrasound systems has prevented characterization of structures Methods Experiment 1 was a pilot study to develop methods of immobilization (physical restraint vs. general anesthesia and determine technical factors affecting ovarian images using ultrasound bio-microscopy in rats vs. mice. The hair coat was removed over the thoraco-lumber area using depilation cream, and a highly viscous acoustic gel was applied while the animals were maintained in sternal recumbency. In Experiment 2, changes in ovarian structures during the estrous cycle were monitored by twice daily ultrasonography in 10 mice for 2 estrous cycles. Results Ovarian images were not distinct in rats due to attenuation of ultrasound waves. Physical restraint, without general anesthesia, was insufficient for immobilization in mice. By placing the transducer face over the dorsal flank, the kidney was visualized initially as a point of reference. A routine of moving the transducer a few millimetres caudo-laterally from the kidney was established to quickly and consistently localize the ovaries; the total time to scan both ovaries in a mouse was about 10 minutes. By comparing vaginal cytology with non-anesthetized controls, repeated exposure to anesthesia did not affect the estrous cycle. Temporal changes in the number of follicles in 3 different size categories support the hypothesis that follicles ≥ 20 microns develop in a wave-like fashion. Conclusion The mouse is a suitable model for the study of ovarian dynamics using transcutaneous ultrasound bio-microscopy. Repeated general anesthesia for examination had no apparent effect on the estrous cycle, and preliminary results revealed a wave-like pattern of ovarian follicle development in mice.

  2. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    Science.gov (United States)

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  3. Ultrasound assessment of endometrial cavity in perimenopausal women on oral progesterone for abnormal uterine bleeding: comparison of diagnostic accuracy of imaging with hysteroscopy-guided biopsy.

    Science.gov (United States)

    Dasgupta, Subhankar; Dasgupta, Shyamal; Sharma, Partha Pratim; Mukherjee, Amitabha; Ghosh, Tarun Kumar

    2011-11-01

    To investigate the effect of oral progesterone on the accuracy of imaging studies performed to detect endometrial pathology in comparison to hysteroscopy-guided biopsy in perimenopausal women on progesterone treatment for abnormal uterine bleeding. The study population comprised of women aged 40-55 years with complaints of abnormal uterine bleeding who were also undergoing oral progesterone therapy. Women with a uterus ≥ 12 weeks' gestation size, previous abnormal endometrial biopsy, cervical lesion on speculum examination, abnormal Pap smear, active pelvic infection, adnexal mass on clinical examination or during ultrasound scan and a positive pregnancy test were excluded. A transvaginal ultrasound followed by saline infusion sonography were done. On the following day, a hysteroscopy followed by a guided biopsy of the endometrium or any endometrial lesion was performed. Comparison between the results of the imaging study with the hysteroscopy and guided biopsy was done. The final analysis included 83 patients. For detection of overall pathology, polyp and fibroid transvaginal ultrasound had a positive likelihood ratio of 1.65, 5.45 and 5.4, respectively, and a negative likelihood ratio of 0.47, 0.6 and 0.43, respectively. For detection of overall pathology, polyp and fibroid saline infusion sonography had a positive likelihood ratio of 4.4, 5.35 and 11.8, respectively, and a negative likelihood ratio of 0.3, 0.2 and 0.15, respectively. In perimenopausal women on oral progesterone therapy for abnormal uterine bleeding, imaging studies cannot be considered as an accurate method for diagnosing endometrial pathology when compared to hysteroscopy and guided biopsy. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  4. The combination of ovarian volume and outline has better diagnostic accuracy than prostate-specific antigen (PSA) concentrations in women with polycystic ovarian syndrome (PCOs).

    Science.gov (United States)

    Bili, Eleni; Bili, Authors Eleni; Dampala, Kaliopi; Iakovou, Ioannis; Tsolakidis, Dimitrios; Giannakou, Anastasia; Tarlatzis, Basil C

    2014-08-01

    The aim of this study was to determine the performance of prostate specific antigen (PSA) and ultrasound parameters, such as ovarian volume and outline, in the diagnosis of polycystic ovary syndrome (PCOS). This prospective, observational, case-controlled study included 43 women with PCOS, and 40 controls. Between day 3 and 5 of the menstrual cycle, fasting serum samples were collected and transvaginal ultrasound was performed. The diagnostic performance of each parameter [total PSA (tPSA), total-to-free PSA ratio (tPSA:fPSA), ovarian volume, ovarian outline] was estimated by means of receiver operating characteristic (ROC) analysis, along with area under the curve (AUC), threshold, sensitivity, specificity as well as positive (+) and negative (-) likelihood ratios (LRs). Multivariate logistical regression models, using ovarian volume and ovarian outline, were constructed. The tPSA and tPSA:fPSA ratio resulted in AUC of 0.74 and 0.70, respectively, with moderate specificity/sensitivity and insufficient LR+/- values. In the multivariate logistic regression model, the combination of ovarian volume and outline had a sensitivity of 97.7% and a specificity of 97.5% in the diagnosis of PCOS, with +LR and -LR values of 39.1 and 0.02, respectively. In women with PCOS, tPSA and tPSA:fPSA ratio have similar diagnostic performance. The use of a multivariate logistic regression model, incorporating ovarian volume and outline, offers very good diagnostic accuracy in distinguishing women with PCOS patients from controls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Clinical importance of appearance of cesarean hysterotomy scar at transvaginal ultrasonography in nonpregnant women.

    Science.gov (United States)

    Vikhareva Osser, Olga; Valentin, Lil

    2011-03-01

    To estimate the association between the appearance of cesarean hysterotomy scars at transvaginal ultrasound examination of nonpregnant women and the outcome of subsequent pregnancies and deliveries. A total of 162 women who had ever given birth by cesarean underwent transvaginal ultrasound examination of the hysterotomy scar 6 to 9 months after the latest cesarean delivery. Published ultrasound definitions of large scar defects were used. The appearance of the hysterotomy scar at ultrasound examination was compared with the outcome of subsequent pregnancies and deliveries. Clinical information on subsequent pregnancies was obtained from medical records. Six women were lost to follow-up, leaving 156 for analysis. Of these 156 women, 69 became pregnant after the ultrasound examination (99 pregnancies, 65 deliveries). There were no placental complications or scar pregnancies. At the first repeat cesarean delivery after the ultrasound examination, 5.3% (1/19) of the women with an intact scar or a small scar defect had uterine dehiscence or rupture compared with 42.9% (3/7) of those with a large defect (P=.047), odds ratio 11.8 (95% confidence interval 0.7-746). Our results point toward a likely association between large defects in the hysterotomy scar after cesarean delivery detected by transvaginal ultrasonography in nonpregnant women and uterine rupture or dehiscence in subsequent pregnancy.

  6. Transvaginal echography in the diagnose of the ectopic pregnancy

    International Nuclear Information System (INIS)

    Betancourt, Claudia; Rivera, Humberto

    1993-01-01

    The ultrasound findings in 21 patients with confirmed ectopic pregnancy were reviewed. The inclusion criteria were those of anatomopathologic confirmation of this diagnosis. All patients were examined with trans-vaginal ultrasound. The most important echographic finding was and an adnexial mass, of mix nature, associated with fluid at the posterior cul-de-sac, in 86% of our patients

  7. Prevalence of ovarian adrenal rest tumours and polycystic ovaries in females with congenital adrenal hyperplasia: results of ultrasonography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stikkelbroeck, Nike M.M.L.; Schouten, Diana; Otten, Barto J. [University Medical Centre Nijmegen, Department of Paediatric Endocrinology, P.O. Box 9101, Nijmegen (Netherlands); Hermus, Ad R.M.M. [University Medical Centre Nijmegen, Department of Endocrinology, P.O. Box 9101, Nijmegen (Netherlands); Suliman, Harold M.; Jager, Gerrit J. [University Medical Centre Nijmegen, Department of Radiology, P.O. Box 9101, Nijmegen (Netherlands); Braat, Didi D.M. [University Medical Centre Nijmegen, Department of Obstetrics and Gynaecology, P.O. Box 9101, Nijmegen (Netherlands)

    2004-10-01

    The aim of the investigation was to assess the prevalence of ovarian adrenal rest tumours and polycystic ovaries in female patients with congenital adrenal hyperplasia (CAH). Thirteen female CAH patients (median age 19.8 years, range 14.8-23.5 years) underwent transvaginal (n=6) or transabdominal (n=7) ultrasonography by a gynaecologist and MR imaging (n=13) of the ovaries (pre and post contrast-enhanced T1- and T2-weighted images). Ovarian adrenal rest tumours were defined as small hypoechoic and multifocal nodules on ultrasound and isointense lesions on T1- and hypointense on T2-weighted MR images (derived from characteristics of testicular adrenal rest tumours). Polycystic ovaries were defined as the presence of {>=}10 follicles arranged peripherally around or scattered throughout increased stroma. No ovarian adrenal rest tumours were found either on ultrasound, or by MR imaging. Polycystic ovaries were found in 2 of the 13 patients (15.4%), both with ultrasound and MR. No ovarian adrenal rest tumours were detected in these female CAH patients, which suggests that ovarian adrenal rest tumours in CAH females are rare. The prevalence of polycystic ovaries corresponded to that in the general population. From these results, we would suggest that routine ovarian imaging in CAH females is not indicated. However, when ovarian dysfunction is present, ovarian imaging is advised, first by ultrasonography, to detect ovarian adrenal rest tumours or polycystic ovaries. (orig.)

  8. Prevalence of ovarian adrenal rest tumours and polycystic ovaries in females with congenital adrenal hyperplasia: results of ultrasonography and MR imaging

    International Nuclear Information System (INIS)

    Stikkelbroeck, Nike M.M.L.; Schouten, Diana; Otten, Barto J.; Hermus, Ad R.M.M.; Suliman, Harold M.; Jager, Gerrit J.; Braat, Didi D.M.

    2004-01-01

    The aim of the investigation was to assess the prevalence of ovarian adrenal rest tumours and polycystic ovaries in female patients with congenital adrenal hyperplasia (CAH). Thirteen female CAH patients (median age 19.8 years, range 14.8-23.5 years) underwent transvaginal (n=6) or transabdominal (n=7) ultrasonography by a gynaecologist and MR imaging (n=13) of the ovaries (pre and post contrast-enhanced T1- and T2-weighted images). Ovarian adrenal rest tumours were defined as small hypoechoic and multifocal nodules on ultrasound and isointense lesions on T1- and hypointense on T2-weighted MR images (derived from characteristics of testicular adrenal rest tumours). Polycystic ovaries were defined as the presence of ≥10 follicles arranged peripherally around or scattered throughout increased stroma. No ovarian adrenal rest tumours were found either on ultrasound, or by MR imaging. Polycystic ovaries were found in 2 of the 13 patients (15.4%), both with ultrasound and MR. No ovarian adrenal rest tumours were detected in these female CAH patients, which suggests that ovarian adrenal rest tumours in CAH females are rare. The prevalence of polycystic ovaries corresponded to that in the general population. From these results, we would suggest that routine ovarian imaging in CAH females is not indicated. However, when ovarian dysfunction is present, ovarian imaging is advised, first by ultrasonography, to detect ovarian adrenal rest tumours or polycystic ovaries. (orig.)

  9. Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.

    Science.gov (United States)

    Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H

    2017-12-01

    Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound-guided

  10. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  11. Persistence of microbial contamination on transvaginal ultrasound probes despite low-level disinfection procedure.

    Directory of Open Access Journals (Sweden)

    Fatima M'Zali

    Full Text Available AIM OF THE STUDY: In many countries, Low Level Disinfection (LLD of covered transvaginal ultrasound probes is recommended between patients' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms. MATERIALS AND METHODS: Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods. RESULTS: A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe; Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe. No fungi were isolated. CONCLUSION: Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  13. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours.

    Science.gov (United States)

    Garg, Sugandha; Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-08-01

    IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use.

  14. Sonographic diagnosis of the contralateral ovary in patients with ovarian tumor

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Jung, Jin Young; Lee, Chang Ho; Suh; Jung Ho

    1999-01-01

    To assess the usefulness of transvaginal sonography(TVS) in the detection of normal contralateral ovary and disease involvement of contralateral ovary in the patients with ovarian tumor. We compared sonographic findings with histopathologic findings of the contralateral ovary retrospectively in 87 patients, who underwent preoperative ultrasonography and laparotomy for ovarian tumor for recent 4 years. Abnormality of the contralateral ovary was confirmed in 49 (56.3%) of 87 patients. The pathologic diagnoses of contralateral ovarian lesions were bilateral involvement of the same disease in 39 patients, different tumor in four patients and non-tumorous lesion in six patients. Abnormal TVS findings of the contralateral ovary were detected in 34 of 49 patients, which shows diagnostic accuracy of 82.8%. The sensitivity and specificity were 69.4% and 100%, respectively. 15 cases which were not diagnosed by ultrasound were bilateral involvement of the same disease in 10 cases (1 serous cystadenoma, 2 cystadenocarcinoma with low malignant potential, 1 brenner tumor, 1 metastatic endometrioid cancer, 1 metastasis, 4 teratoma) and different lesions in the remaining 5 patients (2 endosalpingiosis, 1 surface inclusion cyst, 2 tuboovarian cyst). Ultrasound of the contralateral ovary in the patients with ovarian tumor shows low to a moderate degree sensitivity and accuracy. So, more intensive and targeted evaluation of contralateral ovary is needed for the more accurate diagnosis and proper treatment.

  15. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours

    Science.gov (United States)

    Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-01-01

    Introduction IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. Aim To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. Materials and Methods A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Results Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. Conclusion IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use. PMID:28969237

  16. Sustained effect of simulation-based ultrasound training on clinical performance

    DEFF Research Database (Denmark)

    Tolsgaard, M G; Ringsted, C; Dreisler, E

    2015-01-01

    on a virtual-reality transvaginal ultrasound simulator until an expert performance level was attained followed by training on a pelvic mannequin. After two months of clinical training, one transvaginal ultrasound scan was recorded for assessment of participants' clinical performance. Two blinded ultrasound...

  17. Ovarian Ectopic Pregnancy: a Rare Case Report

    Directory of Open Access Journals (Sweden)

    N Lotfian

    2017-02-01

    Full Text Available Background and aim: Ovarian pregnancy is an uncommon form of ectopic pregnancy which usually diagnosed so late. The aim of this study is to report a case of ovarian ectopic pregnancy Case presentation: A 19 years old woman, with a history of polycystic ovary, first pregnancy, gestation age 9 weeks and 4 days, visited the doctor. She was complaining of severe abdomen pain and vaginal spotting and she was bedridden because of threatened miscarriage. She had discharged from hospital with progesterone suppository prescription. Requesting a transvaginal ultrasound and heterogeneous echogenic mass (size18×8/5 was shown near the left ovary. It was shown as ectopic pregnancy. The patient was hospitalized by ectopic pregnancy in ovary diagnosis and she was treated by methotrexate. Conclusion: In pregnant women that complain of bleeding and spotting in early pregnancy, in addition to threatened abortion, ectopic pregnancy should exist even in the absence of clinical symptoms, should be considered.

  18. Decontamination of transvaginal ultrasound probes: Review of national practice and need for national guidelines

    International Nuclear Information System (INIS)

    Gray, R.A.; Williams, P.L.; Dubbins, P.A.; Jenks, P.J.

    2012-01-01

    Aim: To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. Materials and methods: A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. Results: There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. Conclusion: While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  1. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  2. ULTRASOUND CRITERIA OF EARLY DIAGNOSTICS OF OVARIAN CARCINOMA

    Directory of Open Access Journals (Sweden)

    L. A. Ashrafyan

    2015-01-01

    Full Text Available Introduction. Ovarian cancer (OC in Russia is ranked the seventh within the structure of general cancer diseases and the third within the gynecological tumors, due to such reasons the problem of early diagnostics is still actual. New technologies, such as color Doppler ultrasonography,3D power Doppler ultrasonography contribute to increasing of opportunities of ultrasound analysis to detect any malignancy signs.Materials and methods. The paper sets out the results of comprehensive ultrasound study of 68 patients with morphologically verified OC at stages IА–В, IIА–В. The control group was made of 100 female patients with morphologically verified ovarian tumors (serosal cystadenomas, thecomas, fibromas. A complex of the following ultrasound methods was used during the study: 2D and 3D ultrasonography in B mode, in color Doppler and power mapping mode, 3D angiography, spectrum Doppler imaging.Results. Maximum size of tumor varied within a range between 37 and 300 mm (108 ± 61.2 mm. It worth noting that no direct dependence between the size of neoplasm and process phase was established. When assessing the echostructure, all ovarian tumors were divided into 3 structure types: cystic type (57.8 % of cases, cystic and solid type (33.3 % of cases, solid type (8.9 % of cases. The conducted analysis of types of small pelvis neoplasm echostructures enabled to evolve the sonographic types of ovarian tumors, more or less associated with the malignant transformation. The most relevanl Doppler ultrasonography exponents characteristic for benignant and malignant processes: resistance index in benignant tumors was 0.56, at OC – 0.32 (р < 0.001; average arterial blood velocity in benignant tumors – 7.8 cm/s, at OC – 20.1 cm/s (р < 0.001; average maximum venous flow velocity in benignant tumors – 3.2 cm/s, at OC – 9.3 cm/s (р < 0.001.Conclusion. Therefore modern ultrasonography can detect and differentiate rather efficiently the localized

  3. Transvaginal Ultrasound in Fertile Patients with Suspected Appendicitis: An Experience Report of Current Practice

    Directory of Open Access Journals (Sweden)

    Malek Tabbara

    2012-01-01

    Full Text Available Background. Transvaginal ultrasound (TVU in female patients with acute right lower quadrant (RLQ abdominal pain is time and infrastructure intensive and not always available. This study aims to evaluate the role of TVU in these patients. Methods. Retrospective analysis identified 224 female patients with RLQ pain and TVU. Results. TVU revealed an underlying pathology in 34 (15% patients, necessitating a diagnostic laparoscopy in 12 patients. Six patients (2% had a true gynaecological emergency. The remaining 23 patients did not require surgery. The other 190 patients with RLQ pain had a bland TVU; 127 (67% were discharged, while 63 patients (33% received a diagnostic laparoscopy. Conclusion. The incidence of true gynaecological emergencies requiring urgent surgical intervention is very low in our patient cohort. TVU is a helpful tool if performed by a physician who is well trained in TVU.

  4. Transvaginal ultrasound in fertile patients with suspected appendicitis: an experience report of current practice.

    Science.gov (United States)

    Tabbara, Malek; Evangelopoulos, Nikolaos; Raio, Luigi; Banz, Vanessa; Zimmermann, Heinz; Kim-Fuchs, Corinne; Exadaktylos, Aristomenis K

    2012-01-01

    Background. Transvaginal ultrasound (TVU) in female patients with acute right lower quadrant (RLQ) abdominal pain is time and infrastructure intensive and not always available. This study aims to evaluate the role of TVU in these patients. Methods. Retrospective analysis identified 224 female patients with RLQ pain and TVU. Results. TVU revealed an underlying pathology in 34 (15%) patients, necessitating a diagnostic laparoscopy in 12 patients. Six patients (2%) had a true gynaecological emergency. The remaining 23 patients did not require surgery. The other 190 patients with RLQ pain had a bland TVU; 127 (67%) were discharged, while 63 patients (33%) received a diagnostic laparoscopy. Conclusion. The incidence of true gynaecological emergencies requiring urgent surgical intervention is very low in our patient cohort. TVU is a helpful tool if performed by a physician who is well trained in TVU.

  5. [Usefulness of transvaginal Doppler color in ovarian neoplasms diagnosis].

    Science.gov (United States)

    Muñoz, H; Martínez, L; Parra, M; Cunill, E; Polanco, M; Leible, S; Romero, C

    1993-01-01

    The vascular resistant evaluation by Doppler waveform is a method used in clinic and research. The neoplastic malignant has an increased growth with an increased amount of neomalignant vessels. The presence of these vessels produce an increase of the transversal section area from the tumoral vascular system, therefore there is a decrease in the vascular resistance. The main objective of this work is to show the usefulness of Doppler waveform as predictor factor of malignity in ovary tumors. Eighteen patients with tumoral mass in the ovary were studied. They were between 21 and 67 years old (mean = 43). The tumoral volume and the flow resistance of blood vessels which irrigated those tumoral mass were evaluated by transvaginal ultrasound with color and pulsed Doppler. The pulsatility index (SD/media) was used. The Chi cuadrado test was used to evaluate the results. The results show the presence of six malignant tumors, three of them with low malignicity and the presence of twelve benign tumors. The age of the patients between both groups (malignant and benign tumors) were significant different (40.7 versus 52 years old, p < 0.001). The mean tumoral volume was 65 ml, with a range of 17 to 225 ml in the group of patients with benign tumors and the mean tumoral volume from patients with malignant tumors was 951 ml with a range of 141 to 3142 ml. The difference in the tumoral in both groups was significative with p < 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  8. To Compare the Diagnostic Effectiveness of Transvaginal Ultrasonography, Sonohisterography and Endometrial Biopsy in Woman with Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    Ahmet Kökden

    2005-12-01

    Full Text Available OBJECTIVE: To compare the effectiveness of saline sonohysterography in abnormal uterine bleeding with endometrial biopsy and transvaginal ultrasound. Design: Controlled clinical study. Settings: Bakirkoy Dr.Sadi Konuk Research and Training Hospital Patients: Total 51 pre and postmenopausal women age between 35 and 73 Interventions: Sonohysterography, endometrial biopsy, transvaginal ultrasound RESULTS: When we compared SIS with endometrail biopsy at the diagnosis of intracavitery lesions like myomas and polyps, endometrial biopsy diagnosed 7 on the other hand SIS diagnosed 12 of pathologies (p

  9. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  10. Serum anti-Mullerian hormone levels after ovarian drilling for the second-line treatment of polycystic ovary syndrome: a pilot-randomized study comparing laparoscopy and transvaginal hydrolaparoscopy.

    Science.gov (United States)

    Giampaolino, Pierluigi; Morra, Ilaria; Della Corte, Luigi; Sparice, Stefania; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe

    2017-01-01

    Aim of the study was to asses and compare serum anti-Mullerian harmone (AMH) levels after laparoscopic ovarian drilling (LOD) and transvaginal hydrolaparoscopy (THL) ovarian drilling in clomifene citrate (CC)-resistant polycystic ovary syndrome (PCOS) patients; secondary outcome was to evaluate postoperative pain to estimate the acceptability of procedures. A total of 246 patients with CC-resistant PCOS were randomized into two groups: 123 underwent LOD and 123 underwent THL ovarian drilling. AMH serum levels were evaluated before and after the procedure; moreover, women were asked to rate pain on a visual analog scale (VAS) from 0 (no pain, perfectly acceptable) to 10 (unbearable pain, completely unacceptable). In both groups, postoperative serum AMH levels were significantly reduced compared to preoperative levels (6.06 ± 1.18 and 5.84 ± 1.16 versus 5.00 ± 1.29 and 4.83 ± 1.10; p ovarian drilling in comparison to THL (3.26 ± 1.1 versus 1.11 ± 0.5; p ovarian drilling is comparable to the LOD in terms of reduction in AMH, but it is preferred by patients in terms of acceptability. These results could support to use of THL ovarian drilling in the treatment of patients with CC- resistant PCOS.

  11. Correlation between transvaginal ultrasound measured endometrial thickness and histopathological findings in Turkish women with abnormal uterine bleeding.

    Science.gov (United States)

    Ozer, Alev; Ozer, Serdar; Kanat-Pektas, Mine

    2016-05-01

    The present study aims to determine how transvaginal ultrasonography and histopathological examination findings are correlated in a cohort of premenopausal and postmenopausal Turkish women with abnormal uterine bleeding. This is a retrospective review of 350 Turkish women who underwent transvaginal ultrasonography and suction curettage as a result of abnormal uterine bleeding. Sonographic appearance of the endometrium was normal in 244 patients (69.7%), while homogeneous thickening was detected in 47 patients (13.4%) and cystic thickening in 21 patients (6.0%). A sonographic diagnosis of endometrial polyp was made in 38 patients (10.9%). Histopathological analysis of endometrial samplings revealed proliferative endometrium (36%), secretory endometrium (24.6%), decidualization (10.9%), endometrial polyp (8.3%), endometritis (6.8%), endometrial hyperplasia (4.6%), irregular shedding (3.7%), atrophic endometrium (3.1%), endometrial cancer (1.1%) and placental retention (0.9%). The sonographic and histopathological findings correlated significantly (χ(2) = 122 768, P = 0.001; r = 0.215, P = 0.001). Approximately 51% of the women with homogeneous endometrial thickening had proliferative endometrium. Only 44.7% of the women with ultrasonographically visualized endometrial polyps had histopathologically diagnosed endometrial polyps. Nearly 57% of the women with cystic endometrial thickening had proliferative endometrium. If there is no facility for hysteroscopy or hysteroscopy-guided endometrial biopsy for women with abnormal uterine bleeding, transvaginal ultrasonography findings can be efficiently used to make a preliminary diagnosis and, thus, notify the pathologists. © 2016 Japan Society of Obstetrics and Gynecology.

  12. Transvaginal six-arm mesh OPUR in women with apical pelvic organ prolapse - analysis of short-term results, pelvic floor ultrasound evaluation.

    Science.gov (United States)

    Kluz, Tomasz; Wlaźlak, Edyta; Surkont, Grzegorz

    2017-01-01

    Analysis of feasibility, efficacy and short-term results after six-arm transvaginal mesh OPUR implantation in women with apical prolapse. The same surgeon operated all of 39 women using mesh OPUR. Preoperatively patients had a standardized interview and clinical examination. Intraoperative and postoperative complications were analyzed. Postoperative evaluation included standardized interview, clinical examination and standardized pelvic floor ultrasound performed with 2D transvaginal probe and 4D abdominal probe. There was no complication that needed operative intervention. Hematomas in 3 patients resolved spontaneously. Transient voiding difficulties which lasted less than 7 days were observed in 5 patients. No erosion was observed. Comparison of pre- and postoperative results in 34 women revealed that in all 3 compartments improvement in POP-Q scale was statistically significant (p mesh needed re-operation. During PFS-TV in 94.1% of patients urethra was normobile or hypermobile. In all of the patients urethral end of the mesh was positioned far enough from the middle part of the urethra (ultrasound) to implant suburethral sling without risk of collision. Sexually active women did not inform of any important discomfort or pain during intercourse. It seems that six-arm OPUR mesh, if implanted under strict surgical rules, gives low risk of complications and high chance to successfully reduce POP symptoms in short term after the operation. It seems that OPUR mesh should not have negative influence on the results after anti-incontinence suburethral sling.

  13. Circumvention of cisplatin resistance in ovarian cancer by combination of cyclosporin A and low-intensity ultrasound.

    Science.gov (United States)

    Yu, Tinghe; Yang, Yan; Zhang, Jiao; He, Haining; Ren, Xueyi

    2015-04-01

    Cisplatin resistance is a challenge in the treatment of ovarian cancer. The aim of this study was to explore if ultrasound can overcome chemoresistance and enhance chemosensitization due to cyclosporin A. Ultrasound and/or cyclosporin A were employed to overcome cisplatin resistance in human ovarian cancer cell line COC1/DDP. Mechanisms were explored from the perspective of: DNA damage, intracellular platinum level, detoxification, and genes related to drug efflux and DNA repair. In vivo therapeutic efficacy was validated in a short-term model (subrenal cell-clot transplantation) in mice and the survival benefit was investigated in an orthotopic cancer model in mice using HO-8910PM cells. The findings were: (i) ultrasound enhanced the effect of cisplatin leading to a lower cell-survival rate (IC50 decreased from 3.19 to 0.35 μg/ml); (ii) ultrasound enhanced cisplatin via direct (increasing the intercellular level of active platinum) and indirect (decreasing the glutathione level, and expression of LRP and ERCC1 genes) mechanisms that intensified cisplatin-induced DNA damage, thus enhancing cell apoptosis and necrosis; (iii) cisplatin followed by ultrasound led to small tumor sizes in the short-term model without exacerbation of the systemic toxicity, and prolonged the survival times in the orthotopic model; and (iv) ultrasound synergized the sensitization due to cyclosporin A in vitro and in vivo. These data demonstrated that ultrasound combined with cyclosporin A overcame cisplatin resistance in ovarian cancer. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Correlation between ovarian chocolate cyst and serum carbohydrate antigen 125 level and the effect of ultrasound-guided interventional sclerotherapy on serum carbohydrate antigen 125 level.

    Science.gov (United States)

    Wang, Si-Ming; Cai, Huai-Qiu; Dong, Xiao-Qiu; Fan, Qiu-Lan; Wang, Lu-Lu; Shao, Xiao-Hui; Zhang, Li-Wei

    2015-01-01

    This study was to investigate the correlation between ovarian chocolate cysts and serum carbohydrate antigen (CA)-125 levels and to demonstrate the effect of ultrasound-guided interventional sclerotherapy (UGIS) on serum CA-125 levels. Based on the serum CA-125 level, as determined by chemiluminescence detection prior to UGIS, 105 patients with ovarian chocolate cysts were divided into the normal group (CA-125 ≤ 35 U/mL, 45 patients) and the abnormal group (35 U/mL history, child-bearing history, abortion history and surgical history. The ultrasonography characteristics were cyst diameter, cyst wall thickness and the side on which the cyst occurred. The correlations between serum CA-125 levels pretreatment and the clinical indicators and ultrasonography characteristics was analyzed. The serum CA-125 levels pretreatment, 3 months post-treatment and 6 months post-treatment were compared. The pretreatment serum CA-125 levels of the 105 patients positively correlated with disease duration (r = 0.3932, P = 0.0040), dysmenorrhea history (r = 0.2351, P = 0.0111), cyst diameter (r = 0.3415, P chocolate cysts. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  15. The Diagnostic Value of Transvaginal Sonograph (TVS), Color Doppler, and Serum Tumor Marker CA125, CEA, and AFP in Ovarian Cancer.

    Science.gov (United States)

    Zhang, Fang; Zhang, Zhou-Long

    2015-06-01

    The purpose of this study is to investigate the diagnostic value of transvaginal sonograph (TVS), color Doppler, and serum tumor marker CA125, CEA, and AFP in ovarian cancer. From June, 2011 to May, 2013, 102 cases with adnexal mass were recruited in this study (32 cases of malignant ovarian cancer and 70 cases of benign ovarian tumor according to pathological diagnosis). TVS, color Doppler, and serum tumor markers were used for tumor diagnosis. The sensitivity, specifity, positive prediction, negative prediction, and Youden's index were analyzed. Of the 102 patients, 32 were diagnosed with malignant ovarian cancer and 70 were diagnosed with benign ovarian tumor according to pathological diagnosis. Based on TVS results, 37 cases were malignant while 65 cases were benign. Based on color Doppler results, 34 cases were malignant while 68 cases were benign. Based on TVS and color Doppler results, 35 cases were malignant while 65 were benign. Based on CA125 test results, 34 cases were malignant while 68 cases were benign. Based on CEA test results, 8 cases were malignant and 94 cases were benign. Bases on AFP test results, 9 cases were malignant while 93 cases were benign. Based on the results of combination tumor marker test, 38 cases were malignant while 64 cases were benign. The combination of TVS, color Doppler, and tumor marker test showed optimal diagnostic value with a sensitivity of 90.63 %, specificity of 97.14 %, positive prediction of 93.94 %, negative prediction of 98.55 %, and Youden's index of 94.02 %. The combination of TVS, color Doppler, and tumor marker test is of great diagnostic value, which should be widely used in clinical practice.

  16. Ultrasound-controlled neuronavigator-guided brain surgery.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-07-01

    The development of a unique neurosurgical navigator is described and a preliminary series of seven cases of intracerebral lesions approached with the assistance of this neuronavigation system under ultrasound control is presented. The clinical series included five low-grade astrocytomas, one chronic intracerebral hematoma, and one porencephalic cyst. Management procedures included biopsy in all cases, drainage of the hematoma, and endoscopy and fenestration for the cyst. The features of the neuronavigation system are interactive reconstructions of preoperative computerized tomography and magnetic resonance imaging data, corresponding intraoperative ultrasound images, versatility of the interchangeable end-effector instruments, graphic presentation of instruments on the reconstructed images, and voice control of the system. The principle of a common axis in the reconstructed images served to align the navigational pointer, biopsy guide, endoscope guide, ultrasound transducer, and surgical microscope to the brain anatomy. Intraoperative ultrasound imaging helped to verify the accuracy of the neuronavigator and check the results of the procedures. The arm of the neuronavigation system served as a holder for instruments, such as the biopsy guide, endoscope guide, and ultrasound transducer, in addition to functioning as a navigational pointer. Also, the surgical microscope was aligned with the neuronavigator for inspection and biopsy of the hematoma capsule to rule out tumor etiology. Voice control freed the neurosurgeon from manual exercises during start-up and calibration of the system.

  17. Transvaginal versus transabdominal sonography in the evaluation of pelvic pathology

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Ullah, H.; Akram, M.H.; Ashfaq, S.; Nayyar, S.

    2004-01-01

    Objective: To find the accuracy of sonographic information provided by transvaginal sonography (TVS) in pelvic pathology as compared to transabdominal sonography (TAS). Materials and Methods: Hundred patients were included in the study from a total of 212 referred for pelvic sonography. Two radiologists independently performed transabdominal and transvaginal sonography of these patients. An independent observer compared the findings. TVS was graded as superior, equal or inferior to TAS depending on the score assigned by them. Results: TVS was considered superior in 63%, equal in 27% and inferior in 10% of the cases as compared to transabdominal sonography. It was graded inferior to TAS in cases with large pelvic masses and superior in majority of cases of ovarian follicle monitoring, polycystic ovaries, endometrial carcinoma and suspected ectopic pregnancy. Cases in which both techniques were considered equal included patients with no abnormal finding, some pelvic masses and advanced pelvic inflammatory disease. Conclusion: Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. However, TAS should still be the initial sonographic technique for routine evaluation of the female pelvis followed by TVS if indicated. In cases of ovarian follicle monitoring, suspected polycystic ovaries, endometrial pathology and suspected ectopic pregnancy, TVS may be used as the initial sonographic technique and can even replace TAS. (author)

  18. Women's perception of transvaginal sonography in a tertiary hospital in nigeria

    International Nuclear Information System (INIS)

    Eze, C.U.; Okaro, A.O.; Nwobi, I.C.

    2008-01-01

    Available studies suggest that pregnant women's views on the desirability of routine ultrasound are Influenced by their perceptions of its potential benefits and concern about possible adverse effects. To assess women's views of transvaginal sonography and to determine any correlation between their perception of the procedure and their prior knowledge and experience of it. We surveyed women presenting with various gynecologic problems or complications of the first trimester. Data collection was by self-administered questionnaires using conveniences sampling technique on women attending the clinic over a period of one year. Only women who had transvaginal sonography were included. A total of 250 women were recruited and interviewed. Transvaginal sonography was considered not embarrassing by 76%, acceptable by 86%, not painful by 87.2% and not stressful by 82% of the women. There were no statistically significant differences in the women's perception of the procedure whether they had prior knowledge and previous experience of the procedure or not (P>0.05). The majority of the women perceived transvaginal sonography favourably. Their perception of the Procedure was favourable whether they had prior knowledge and previous experience of it or not. (author)

  19. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  20. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  2. AMH MEASUREMENT VERSUS OVARIAN ULTRASOUND IN THE DIAGNOSIS OF POLYCYSTIC OVARY SYNDROME IN DIFFERENT PHENOTYPES.

    Science.gov (United States)

    Carmina, Enrico; Campagna, Anna M; Fruzzetti, Franca; Lobo, Rogerio A

    2016-03-01

    This study was designed to assess the value of serum anti-Müllerian hormone (AMH) in the diagnosis of polycystic ovary syndrome (PCOS) in various phenotypes and to assess ovarian ultrasound parameters. We performed a retrospective matched controlled study of 113 females with various PCOS phenotypes and 47 matched controls. The diagnostic utility of AMH measurement and ovarian ultrasound were compared. Using receiver operating characteristic (ROC) curve analyses, the threshold for AMH (>4.7 ng/mL) and ultrasound parameters (follicle number per ovary [FNPO] >22 and ovarian volume [OV] >8 cc) were established. In the entire cohort, AMH had a low sensitivity of 79%; while FNPO and OV were 93% and 68%, respectively. Specificities ranged from 85 to 96%. In classic anovulatory PCOS, AMH exhibited a sensitivity of 91%, and for FNPO and OV the corresponding sensitivities were 92% and 72%. In the ovulatory phenotype, AMH sensitivity was only 50%, while FNPO and OV were 95% and 50%, respectively. In the nonhyperandrogenic phenotype, the sensitivity of AMH was 53% while those for FNPO and OV were 93% and 67%. AMH does not appear to be helpful for all subjects with PCOS but may be of some value in those who are anovulatory. However, FNPO was highly sensitive in all phenotypes, and was the single best criterion assessed for all subjects, suggesting the important role of ultrasound.

  3. Updated ultrasound criteria for polycystic ovary syndrome: reliable thresholds for elevated follicle population and ovarian volume.

    Science.gov (United States)

    Lujan, Marla E; Jarrett, Brittany Y; Brooks, Eric D; Reines, Jonathan K; Peppin, Andrew K; Muhn, Narry; Haider, Ehsan; Pierson, Roger A; Chizen, Donna R

    2013-05-01

    Do the ultrasonographic criteria for polycystic ovaries supported by the 2003 Rotterdam consensus adequately discriminate between the normal and polycystic ovary syndrome (PCOS) condition in light of recent advancements in imaging technology and reliable methods for estimating follicle populations in PCOS? Using newer ultrasound technology and a reliable grid system approach to count follicles, we concluded that a substantially higher threshold of follicle counts throughout the entire ovary (FNPO)-26 versus 12 follicles-is required to distinguish among women with PCOS and healthy women from the general population. The Rotterdam consensus defined the polycystic ovary as having 12 or more follicles, measuring between 2 and 9 mm (FNPO), and/or an ovarian volume (OV) >10 cm(3). Since their initial proposal in 2003, a heightened prevalence of polycystic ovaries has been described in healthy women with regular menstrual cycles, which has questioned the accuracy of these criteria and marginalized the specificity of polycystic ovaries as a diagnostic criterion for PCOS. A diagnostic test study was performed using cross-sectional data, collected from 2006 to 2011, from 168 women prospectively evaluated by transvaginal ultrasonography. Receiver operating characteristic (ROC) curve analyses were performed to determine the appropriate diagnostic thresholds for: (i) FNPO, (ii) follicle counts in a single cross section (FNPS) and (iii) OV. The levels of intra- and inter-observer reliability when five observers used the proposed criteria on 100 ultrasound cases were also determined. Ninety-eight women diagnosed with PCOS by the National Institutes of Health criteria as having both oligo-amenorrhea and hyperandrogenism and 70 healthy female volunteers recruited from the general population. Participants were evaluated by transvaginal ultrasonography at the Royal University Hospital within the Department of Obstetrics, Gynecology and Reproductive Sciences, University of Saskatchewan

  4. Racial and ethnic disparities in universal cervical length screening with transvaginal ultrasound

    Science.gov (United States)

    Haviland, Miriam J; Shainker, Scott A; Hacker, Michele R; Burris, Heather H

    2016-01-01

    Objective Determine if race or ethnicity is associated with missed or late transvaginal cervical length screening in a universal screening program. Methods Retrospective cohort study of nulliparous women with singleton gestations and a fetal anatomical ultrasound from 16-24 weeks' gestation from January, 2012 through November, 2013. We classified women into mutually exclusive racial and ethnic groups: non-Hispanic black (black), Hispanic, Asian, non-Hispanic white (white), and other or unknown race. We used log-binomial regression to calculate the risk ratio (RR) and 95% confidence interval (CI) of missed or late (≥ 20 weeks' gestation) screening vs. optimally-timed screening between the different racial and ethnic groups. Results Among the 2 967 women in our study population, 971 (32.7%) had either missed or late cervical length screening. Compared to white women, black (RR: 1.3; 95% CI:1.1-1.5) and Hispanic (RR:1.2; 95% CI:1.01-1.5) women were more likely to have missed or late screening. Among women screened, black (vs. white) women were more likely to be screened late (RR: 2.2; 95% CI: 1.6-3.1). Conclusions Black and Hispanic women may be more likely to have missed or late cervical length screenings. PMID:26987873

  5. Office microlaparoscopic ovarian drilling (OMLOD) versus conventional laparoscopic ovarian drilling (LOD) for women with polycystic ovary syndrome.

    Science.gov (United States)

    Salah, Imaduldin M

    2013-02-01

    This was a prospective controlled study to compare the beneficial effects of office microlaparoscopic ovarian drilling (OMLOD) under augmented local anesthesia, as a new modality treatment option, compared to those following ovarian drilling with the conventional traditional 10-mm laparoscope (laparoscopic ovarian drilling, LOD) under general anesthesia. The study included 60 anovulatory women with polycystic ovary syndrome (PCOS) who underwent OMLOD (study group) and 60 anovulatory PCOS women, in whom conventional LOD using 10-mm laparoscope under general anesthesia was performed (comparison group). Transvaginal ultrasound scan and blood sampling to measure the serum concentrations of LH, FSH, testosterone and androstenedione were performed before and after the procedure. Intraoperative and postoperative pain scores in candidate women were evaluated during the office microlaparoscopic procedure, in addition to the number of candidates who needed extra analgesia. Women undergoing OMLOD showed good intraoperative and postoperative pain scores. The number of patients discharged within 2 h after the office procedure was significantly higher, without the need for postoperative analgesia in most patients. The LH:FSH ratio, mean serum concentrations of LH and testosterone and free androgen index decreased significantly after both OMLOD and LOD. The mean ovarian volume decreased significantly (P < 0.05) a year after both OMLOD and LOD. There were no significant differences in those results after both procedures. Intra- and postoperatively augmented local anesthesia allows outpatient bilateral ovarian drilling by microlaparoscopy without general anesthesia. The high pregnancy rate, the simplicity of the method and the faster discharge time offer a new option for patients with PCOS who are resistant to clomiphene citrate. Moreover, ovarian drilling could be performed simultaneously during the routine diagnostic microlaparoscopy and integrated into the fertility workup of

  6. Use of transvaginal ultrasound in females with primary bladder neck obstruction. A preliminary study

    Directory of Open Access Journals (Sweden)

    Vikiela Galica

    2015-07-01

    Full Text Available Introduction and aim: The video-urodynamics study is the principal exam to establish a possible primary bladder neck obstruction (PBNO condition. While trans-rectal ultrasonography plays an important role in the evaluation of the low urinary tract symptoms (LUTS and the severity of bladder outlet obstruction (BOO in men, the use of the transvaginal ultrasound (TVUS in women with symptoms suggesting BOO remains unclear. We tried to check the utility of the TVUS in women with PBNO condition. Material and methods: We selected female patients which presented BOO without pelvic organ prolapse (POP. According to the data of the video-urodynamic exam we selected the patients with the suspicion of PBNO. A TVUS in basal and during micturition was performed before and after surgery. Results: TVUS showed a closed bladder neck bladder in basal condition and during micturition similarly to the fluoroscopic image during video-urodynamics. The mean distance from bladder neck to the vaginal mucosa resulted 1.3 cm in this patients. Conclusions: TVUS results worthy in the evaluation of patients with PBNO before and after surgery.

  7. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  8. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    Science.gov (United States)

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  9. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  10. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  13. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  14. [Ultrasound semiotics in recurrent ovarian cancer after optimal cytoreductive surgery].

    Science.gov (United States)

    Baklanova, N S; Kolomiets, L A; Frolova, I G; Viatkina, N V; Krasil'nikov, S É

    2014-01-01

    Features of ultrasound picture of morphologically verified recurrence of ovarian cancer in 21 patients are presented, who received combined treatment including cytoreductive surgery in the form of hysterectomy with oophorectomy, resection of the greater omentum and 6 courses of chemotherapy CAP for ovarian cancer stage III (FIGO). In all patients cytoreductive surgery was optimal--without residual tumor. Recurrence of the disease was detected in 12-48 months in 80.9% of the cases. Three variants of recurrence was revealed by ultrasonography: isolated peritoneal dissemination, in 14.2% of the cases, which was mainly detected during the first 12 months; single entities in the projection of the small pelvis (61.9%) and mixed form (local lesions of small pelvis and peritoneal dissemination) in 23.8% of the cases.

  15. Validation of the Performance of International Ovarian Tumor Analysis (IOTA) Methods in the Diagnosis of Early Stage Ovarian Cancer in a Non-Screening Population.

    Science.gov (United States)

    Froyman, Wouter; Wynants, Laure; Landolfo, Chiara; Bourne, Tom; Valentin, Lil; Testa, Antonia; Sladkevicius, Povilas; Franchi, Dorella; Fischerova, Daniela; Savelli, Luca; Van Calster, Ben; Timmerman, Dirk

    2017-06-02

    The aim of this study was to assess and compare the performance of different ultrasound-based International Ovarian Tumor Analysis (IOTA) strategies and subjective assessment for the diagnosis of early stage ovarian malignancy. This is a secondary analysis of a prospective multicenter cross-sectional diagnostic accuracy study that included 1653 patients recruited at 18 centers from 2009 to 2012. All patients underwent standardized transvaginal ultrasonography by experienced ultrasound investigators. We assessed test performance of the IOTA Simple Rules (SRs), Simple Rules Risk (SRR), the Assessment of Different NEoplasias in the adneXa (ADNEX) model and subjective assessment to discriminate between stage I-II ovarian cancer and benign disease. Reference standard was histology after surgery. 230 (13.9%) patients proved to have stage I-II primary invasive ovarian malignancy, and 1423 (86.1%) had benign disease. Sensitivity and specificity with respect to malignancy (95% confidence intervals) of the original SRs (classifying all inconclusive cases as malignant) were 94.3% (90.6% to 96.7%) and 73.4% (71.0% to 75.6%). Subjective assessment had a sensitivity and specificity of 90.0% (85.4% to 93.2%) and 86.7% (84.9% to 88.4%), respectively. The areas under the receiver operator characteristic curves of SRR and ADNEX were 0.917 (0.902 to 0.933) and 0.905 (0.920 to 0.934), respectively. At a 1% risk cut-off, sensitivity and specificity for SRR were 100% (98.4% to 100%) and 38.0% (35.5% to 40.6%), and for ADNEX were 100% (98.4% to 100%) and 19.4% (17.4% to 21.5%). At a 30% risk cut-off, sensitivity and specificity for SRR were 88.3% (83.5% to 91.8%) and 81.1% (79% to 83%), and for ADNEX were 84.5% (80.5% to 89.6%) and 84.5% (82.6% to 86.3%). This study shows that all three IOTA strategies have good ability to discriminate between stage I-II ovarian malignancy and benign disease.

  16. Therapeutic Ultrasound Examination of Follicular Reserve, and Ovarian Tissue Angiogenesis in Mice, 14 Days after Heterotopic Transplantation

    Directory of Open Access Journals (Sweden)

    N Abtahi

    2014-06-01

    Results: The study results showed that the CD31 angiogenic factor was expressed more in the irradiated animals than in control group animals and ultrasound-therapy resulted in better follicular preservation. Conclusion: The ultrasound therapy can improve preservation of ovarian follicle .This is probably due to acceleration of angiogenesis and increase in production of growth factors by low intensity pulse ultrasound.

  17. Ultrasound-guided interstitial brachytherapy in the treatment of advanced vaginal recurrences from cervical and endometrial carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Weitmann, H.D.; Knocke, T.H.; Waldhaeusl, C.; Poetter, R. [Dept. of Radiotherapy and Radiobiology, Medical Univ. of Vienna (Austria)

    2006-02-01

    Background: in advanced vaginal recurrences of cervical and endometrial carcinomas therapeutic options are rare because of preceding therapy. Patients and methods: 23 patients developing advanced vaginal recurrences of cervical and endometrial carcinomas were included. 15 patients started with external-beam therapy to the pelvis and eight patients after preceding radiotherapy underwent brachytherapy alone. All patients had ultrasound-guided implantation of transvaginal or transperineal interstitial needles for brachytherapy. Median prescribed total dose was 64 Gy. Results: 18 patients (78%) achieved complete remission. Six patients are alive without tumor and one with tumor after a median follow-up of 64 months. 14 patients died of tumor and two of intercurrent disease. 5-year disease-specific survival and local control rate were 43% and 47%, respectively, in patients with complete remission. Univariate analysis found time to relapse > 2 years, initial diameter {<=} 4 cm, initial volume < 15 cm{sup 3}, no extension to the pelvic side wall, volume before brachytherapy < 7.5 cm{sup 3}, brachytherapy coverage index > 0.8, and prescribed total dose > 64 Gy being positive predictors for local control and survival. Conclusion: the use of ultrasound guidance for placement of interstitial needles in template-based brachytherapy of advanced recurrent gynecologic malignancies is a feasible, safe, and cheap method with encouraging results. Today, ultrasound imaging can be also used to some extent for treatment planning which requires further development. Patient- and treatment-related prognostic factors can be defined. (orig.)

  18. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  19. A 2-stage ovarian cancer screening strategy using the Risk of Ovarian Cancer Algorithm (ROCA) identifies early-stage incident cancers and demonstrates high positive predictive value.

    Science.gov (United States)

    Lu, Karen H; Skates, Steven; Hernandez, Mary A; Bedi, Deepak; Bevers, Therese; Leeds, Leroy; Moore, Richard; Granai, Cornelius; Harris, Steven; Newland, William; Adeyinka, Olasunkanmi; Geffen, Jeremy; Deavers, Michael T; Sun, Charlotte C; Horick, Nora; Fritsche, Herbert; Bast, Robert C

    2013-10-01

    A 2-stage ovarian cancer screening strategy was evaluated that incorporates change of carbohydrate antigen 125 (CA125) levels over time and age to estimate risk of ovarian cancer. Women with high-risk scores were referred for transvaginal ultrasound (TVS). A single-arm, prospective study of postmenopausal women was conducted. Participants underwent an annual CA125 blood test. Based on the Risk of Ovarian Cancer Algorithm (ROCA) result, women were triaged to next annual CA125 test (low risk), repeat CA125 test in 3 months (intermediate risk), or TVS and referral to a gynecologic oncologist (high risk). A total of 4051 women participated over 11 years. The average annual rate of referral to a CA125 test in 3 months was 5.8%, and the average annual referral rate to TVS and review by a gynecologic oncologist was 0.9%. Ten women underwent surgery on the basis of TVS, with 4 invasive ovarian cancers (1 with stage IA disease, 2 with stage IC disease, and 1 with stage IIB disease), 2 ovarian tumors of low malignant potential (both stage IA), 1 endometrial cancer (stage I), and 3 benign ovarian tumors, providing a positive predictive value of 40% (95% confidence interval = 12.2%, 73.8%) for detecting invasive ovarian cancer. The specificity was 99.9% (95% confidence interval = 99.7%, 100%). All 4 women with invasive ovarian cancer were enrolled in the study for at least 3 years with low-risk annual CA125 test values prior to rising CA125 levels. ROCA followed by TVS demonstrated excellent specificity and positive predictive value in a population of US women at average risk for ovarian cancer. Copyright © 2013 American Cancer Society.

  20. Minimizing the Risk of Infection and Bleeding at Trans-Vaginal Ultrasound-Guided Ovum Pick-up: Results of a Prospective Web-Based World-Wide Survey.

    Science.gov (United States)

    Bhandari, Harish; Agrawal, Rina; Weissman, Ariel; Shoham, Gon; Leong, Milton; Shoham, Zeev

    2015-12-01

    The objective of this study was to identify clinical practices worldwide, which would help in recognizing women at risk of excessive bleeding or of developing pelvic infection following trans-vaginal ovum pick-up (TV-OPU), measures taken to minimize risks and their management. A prospective, web-based questionnaire with distinct questions related to the practice of TV-OPU. A total of 155 units from 55 countries performing 97,200 IVF cycles annually responded to this web-based survey. A majority (65 %) responded that they would routinely carry out full blood count, while 35 % performed coagulation profile. Less than a third agreed screening women for vaginal infections. About a third used both sterile water and antiseptic to minimize ascending infection, and 52 % used antibiotics for prophylaxis. Doppler ultrasound was routinely used by 20 % of clinicians. 73 % of the clinicians preferred conservative management as their first line management for patients diagnosed with intra-abdominal bleeding. The study has identified a wide variation in the practices of minimizing infection and bleeding complications. The dearth of good quality evidence may be responsible for the lack of published guidelines, and therefore a lack of consensus on the optimum practice for minimizing the risk of infection and bleeding during TV-OPU.

  1. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  2. HematoPorphyrin Monomethyl Ether polymer contrast agent for ultrasound/photoacoustic dual-modality imaging-guided synergistic high intensity focused ultrasound (HIFU) therapy.

    Science.gov (United States)

    Yan, Sijing; Lu, Min; Ding, Xiaoya; Chen, Fei; He, Xuemei; Xu, Chunyan; Zhou, Hang; Wang, Qi; Hao, Lan; Zou, Jianzhong

    2016-08-18

    This study is to prepare a hematoporphyrin monomethyl ether (HMME)-loaded poly(lactic-co-glycolic acid) (PLGA) microcapsules (HMME/PLGA), which could not only function as efficient contrast agent for ultrasound (US)/photoacoustic (PA) imaging, but also as a synergistic agent for high intensity focused ultrasound (HIFU) ablation. Sonosensitizer HMME nanoparticles were integrated into PLGA microcapsules with the double emulsion evaporation method. After characterization, the cell-killing and cell proliferation-inhibiting effects of HMME/PLGA microcapsules on ovarian cancer SKOV3 cells were assessed. The US/PA imaging-enhancing effects and synergistic effects on HIFU were evaluated both in vitro and in vivo. HMME/PLGA microcapsules were highly dispersed with well-defined spherical morphology (357 ± 0.72 nm in diameter, PDI = 0.932). Encapsulation efficiency and drug-loading efficiency were 58.33 ± 0.95% and 4.73 ± 0.15%, respectively. The HMME/PLGA microcapsules remarkably killed the SKOV3 cells and inhibited the cell proliferation, significantly enhanced the US/PA imaging results and greatly enhanced the HIFU ablation effects on ovarian cancer in nude mice by the HMME-mediated sono-dynamic chemistry therapy (SDT). HMME/PLGA microcapsules represent a potential multifunctional contrast agent for HIFU diagnosis and treatment, which might provide a novel strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy for cancers by SDT in clinic.

  3. Can anyone screen for deep infiltrating endometriosis with transvaginal ultrasound?

    Science.gov (United States)

    Piessens, Sofie; Healey, Martin; Maher, Peter; Tsaltas, Jim; Rombauts, Luk

    2014-10-01

    Surgical treatment of deep infiltrating endometriosis (DIE) is complex, and preoperative diagnosis benefits both surgeon and patient. Studies in expert centres have reported high accuracy for transvaginal ultrasound (TVUS) diagnosis of DIE. External validation of these findings has been limited, and no information is available on how quickly these skills can be acquired. The aim of this study was to measure the learning curve of DIE-TVUS and to identify the causes for inaccuracies in the diagnosis of bowel lesions and Pouch of Douglas (POD) obliteration. Following one week of training at the University of São Paulo (Brazil), 205 consecutive women with a history of endometriosis symptoms were prospectively assessed by TVUS after minimal bowel preparation. TVUS findings were correlated with laparoscopic findings in eighty-five cases to assess the accuracy. The LC-CUSUM and CUSUM were used to assess the learning curve and maintenance of competency, respectively. The sensitivity and specificity for DIE of the bladder, vagina and bowel were 33% and 100%, 80% and 100%, and 88% and 93%, respectively. The sensitivity and specificity for the presence of POD obliteration were 88% and 90%, respectively. LC-CUSUM analysis confirmed that competency for DIE-TVUS was achieved within 38 scans for the detection of POD obliteration and within 36 scans for the detection of bowel nodules. Competency was maintained for the remainder of the scans as assessed by the CUSUM. After one week of DIE-TVUS training, competency can be achieved within forty procedures, allowing diagnosis of DIE with similar diagnostic accuracy as reported by centres of excellence. © 2014 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  4. High-intensity focused ultrasound for potential treatment of polycystic ovary syndrome: toward a noninvasive surgery.

    Science.gov (United States)

    Shehata, Islam A; Ballard, John R; Casper, Andrew J; Hennings, Leah J; Cressman, Erik; Ebbini, Emad S

    2014-02-01

    To investigate the feasibility of using high-intensity focused ultrasound (HIFU), under dual-mode ultrasound arrays (DMUAs) guidance, to induce localized thermal damage inside ovaries without damage to the ovarian surface. Laboratory feasibility study. University-based laboratory. Ex vivo canine and bovine ovaries. DMUA-guided HIFU. Detection of ovarian damage by ultrasound imaging, gross pathology, and histology. It is feasible to induce localized thermal damage inside ovaries without damage to the ovarian surface. DMUA provided sensitive imaging feedback regarding the anatomy of the treated ovaries and the ablation process. Different ablation protocols were tested, and thermal damage within the treated ovaries was histologically characterized. The absence of damage to the ovarian surface may eliminate many of the complications linked to current laparoscopic ovarian drilling (LOD) techniques. HIFU may be used as a less traumatic tool to perform LOD. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Using trainable segmentation and watershed transform for identifying unilocular and multilocular cysts from ultrasound images of ovarian tumour

    Science.gov (United States)

    Ibrahim, Dheyaa Ahmed; Al-Assam, Hisham; Du, Hongbo; Jassim, Sabah

    2017-05-01

    Ovarian masses are categorised into different types of malignant and benign. In order to optimize patient treatment, it is necessary to carry out pre-operational characterisation of the suspect ovarian mass to determine its category. Ultrasound imaging has been widely used in differentiating malignant from benign cases due to its safe and non-intrusive nature, and can be used for determining the number of cysts in the ovary. Presently, the gynaecologist is tasked with manually counting the number of cysts shown on the ultrasound image. This paper proposes, a new approach that automatically segments the ovarian masses and cysts from a static B-mode image. Initially, the method uses a trainable segmentation procedure and a trained neural network classifier to accurately identify the position of the masses and cysts. After that, the borders of the masses can be appraised using watershed transform. The effectiveness of the proposed method has been tested by comparing the number of cysts identified by the method against the manual examination by a gynaecologist. A total of 65 ultrasound images were used for the comparison, and the results showed that the proposed solution is a viable alternative to the manual counting method for accurately determining the number of cysts in a US ovarian image.

  6. Three-dimensional transvaginal ultrasound: clinical implementation in assessing uterine cavity

    OpenAIRE

    Abdelaziz E. Tammam; Mostafa M. Khodry; Shymaa M. A. Elnagar; Ahmed H. Abdella; Sayed A. M. Taha

    2015-01-01

    Background: Three-dimensional transvaginal ultrasonography (3D TVS) represents a new technique of imaging and provides a unique diagnostic tool for non-invasive examination of the uterine morphology and diagnosis of congenital uterine anomalies. In this study the clinical value of 3D TVS in diagnosis of uterine cavity abnormalities were evaluated. Methods: A prospective of diagnostic accuracy study included 226 patients with various clinical presentations; infertility, recurrent pregnancy ...

  7. Ultrasound-guided sacroiliac joint injection technique.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2008-07-01

    We describe a case report and technique for using a portable ultrasound scanner and a curvilinear transducer (4-5MHz) (SonoSite Micromaxx SonoSite, Inc. 21919 30th Drive SE Bothwell W. A.) to guide sacroiliac joint (SIJ) injection. A 42-year-old male presented with chronic lower back pain centered on his left SIJ. His pain averaged 7 out of 10 (numerical rating scale). For the ultrasound-guided SIJ injection the patient was placed in the prone position. The ultrasound transducer was oriented in a transverse orientation at the level of the sacral hiatus. Here the sacral cornuae were identified. Moving the transducer laterally from here, the lateral edge of the sacrum was identified. This bony edge was followed in a cephalad direction with the transducer maintained in a transverse orientation. A second bony contour, the ileum, was identified. The cleft between both bony contours represented the sacroiliac joint. This was found at 4.5 cm depth. Real-time imaging was used to direct a 22G spinal needle into the SIJ, where solution was injected under direct vision. The patient\\'s pain intensity decreased to a 2 out of 10 (numerical rating scale). Function improved and the patient was able to return to work. These improvements were maintained at 16 weeks. Ultrasound guidance does not expose patients and personnel to radiation and is readily accessible. Ultrasound-guided SIJ injections may have particular applications in the management of chronic lower back pain in certain clinical scenarios (e.g. pregnancy). Future studies to demonstrate efficacy and reproducibility are needed.

  8. Initial evaluation and referral guidelines for management of pelvic/ovarian masses.

    Science.gov (United States)

    Le, Tien; Giede, Christopher; Salem, Shia; Lefebvre, Guylaine; Rosen, Barry; Bentley, James; Kupets, Rachel; Power, Patti; Renaud, Marie-Claude; Bryson, Peter; Davis, Donald B; Lau, Susie; Lotocki, Robert; Senikas, Vyta; Morin, Lucie; Bly, Stephen; Butt, Kimberly; Cargill, Yvonne M; Denis, Nanette; Gagnon, Robert; Hietala-Coyle, Marja Anne; Lim, Kenneth Ian; Ouellet, Annie; Raciot, Maria-Hélène

    2009-07-01

    To optimize the management of adnexal masses and to assist primary care physicians and gynaecologists determine which patients presenting with an ovarian mass with a significant risk of malignancy should be considered for gynaecologic oncology referral and management. Laparoscopic evaluation, comprehensive surgical staging for early ovarian cancer, or tumour debulking for advanced stage ovarian cancer. To optimize conservative versus operative management of women with possible ovarian malignancy and to optimize the involvement of gynaecologic oncologists in planning and delivery of treatment. Published literature was retrieved through searches of PubMed or MEDLINE, CINAHL, and the Cochrane Library, using appropriate controlled vocabulary and key words. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified by searching the web sites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. 1. Primary care physicians and gynaecologists should always consider the possibility of an underlying ovarian cancer in patients in any age group who present with an adnexal or ovarian mass. (II-2B) 2. Appropriate workup of a perimenopausal or postmenopausal woman presenting with an adnexal mass should include evaluation of symptoms and signs suggestive of malignancy, such as persistent pelvic/abdominal pain, urinary urgency/frequency, increased abdominal size/bloating, and difficulty eating. In addition, CA125 measurement should be considered. (II-2B) 3. Transvaginal or transabdominal ultrasound examination is recommended as part of the initial workup of a complex adnexal/ovarian mass. (II-2B) 4. Ultrasound reports should be standardized to include size and unilateral/bilateral location of the adnexal mass and

  9. Ultrasound guided electrochemotherapy for the treatment of a clear ...

    African Journals Online (AJOL)

    Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic ...

  10. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... organs and to examine a baby in pregnant women and the brain and hips in infants. It’s ... Transvaginal ultrasound. The transducer is inserted into a woman's vagina to view the uterus and ovaries. top ...

  13. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  14. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  15. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  16. Faculty staff-guided versus self-guided ultrasound training for internal medicine residents.

    Science.gov (United States)

    Alba, George A; Kelmenson, Daniel A; Noble, Vicki E; Murray, Alice F; Currier, Paul F

    2013-11-01

    Ultrasonography is of growing importance within internal medicine (IM), but the optimal method of training doctors to use it is uncertain. In this study, the authors provide the first objective comparison of two approaches to training IM residents in ultrasonography. In this randomised trial, a simulation-based ultrasound training curriculum was implemented during IM intern orientation at a tertiary care teaching hospital. All 72 incoming interns attended a lecture and were given access to online modules. Interns were then randomly assigned to a 4-hour faculty-guided (FG) or self-guided (SG) ultrasound training session in a simulation laboratory with both human and manikin models. Interns were asked to self-assess their competence in ultrasonography and underwent an objective structured clinical examination (OSCE) to assess their competence in basic and procedurally oriented ultrasound tasks. The primary outcome was the score on the OSCE. Faculty-guided training was superior to self-guided training based on the OSCE scores. Subjects in the FG training group achieved significantly higher OSCE scores on the two subsets of task completion (0.9-point difference, 95% confidence interval [CI] 0.27-1.54; p = 0.008) and ultrasound image quality (2.43-point difference, 95% CI 1.5-3.36; p training groups demonstrated an increase in self-assessed competence after their respective training sessions and there was little difference between the groups. Subjects rated the FG training group much more favourably than the SG training group. Both FG and SG ultrasound training curricula can improve the self-reported competence of IM interns in ultrasonography. However, FG training was superior to SG training in both skills acquisition and intern preference. Incorporating mandatory ultrasound training into IM residencies can address the perceived need for ultrasound training, improve confidence and procedural skills, and may enhance patient safety. However, the optimal training method

  17. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  19. Effect of stem cell transplantation of premature ovarian failure in animal models and patients: A meta-analysis and case report.

    Science.gov (United States)

    Chen, Lei; Guo, Shilei; Wei, Cui; Li, Honglan; Wang, Haiya; Xu, Yan

    2018-05-01

    Stem cell transplantation has been considered a promising therapeutic approach for premature ovarian failure (POF). However, to date, no quantitative data analysis of stem cell therapy for POF has been performed. Therefore, the present study performed a meta-analysis to assess the efficacy of stem cell transplantation in improving ovarian function in animal models of POF. In addition, a case report of a patient with POF subjected to stem cell treatment was included to demonstrate that stem cell therapy also contributes to the recovery of ovarian function in patients. Published studies were identified by a systematic review of the PubMed, Embase, and Cochrane's library databases, and references cited in associated reviews were also considered. Data regarding follicle-stimulating hormone (FSH), estradiol (E2), ovarian weight, follicle count, the number of pregnancies and other parameters, including delivery route and cell type, were extracted. Pooled analysis, sensitivity analyses, subgroup analyses and meta-regression were performed. In the case of POF, transvaginal ultrasound (TVS), abdominal ultrasound (TAS) and color Doppler flow imaging (CDFI) were performed to observe the endometrial morphology and blood flow signals in the patient. Overall, pooled results from 16 pre-clinical studies demonstrated that stem cell-based therapy significantly improved FSH levels [standardized mean difference (SMD)=-1.330; 95% confidence interval (CI), -(2.095-0.565); P=0.001], E2 levels (SMD=2.334; 95% CI, 1.350-3.319; Pstem cell-based therapy may be an effective method for the resumption of ovarian function in a patient and in animal models of POF; however, large-scale and high-quality future studies are required to confirm the present findings due to heterogeneity.

  20. Laparoscopic sacrocolpopexy for recurrent pelvic organ prolapse after failed transvaginal polypropylene mesh surgery.

    Science.gov (United States)

    Schmid, Corina; O'Rourke, Peter; Maher, Christopher

    2013-05-01

    A prospective case series to assess the safety and efficacy of laparoscopic sacrocolpopexy for the surgical management of recurrent pelvic organ prolapse (POP) after transvaginal polypropylene mesh prolapse surgery. Between January and December 2010, women with post-hysterectomy recurrent prolapse (≥ stage 2 POP-Q) after transvaginal polypropylene mesh prolapse surgery were included. Perioperative morbidity and short-term complications were recorded and evaluated. Surgical outcomes were objectively assessed utilising the Pelvic Organ Prolapse Quantification system (POP-Q), the validated, condition-specific Australian Pelvic Floor Questionnaire (APFQ) and the Patient Global Impression of Improvement (PGI-I) at 12 months. All 16 women in this study had undergone surgery with trocar-guided transvaginal polypropylene mesh kits. In 75% the recurrent prolapse affected the compartment of prior mesh surgery with the anterior (81%) and apical (75%) compartment prolapse predominating. At a mean follow-up of 12 months, all women had resolution of awareness of prolapse, had transvaginal mesh surgery is feasible and safe. Further widespread evaluation is required.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  2. Preconception folic acid use modulates estradiol and follicular responses to ovarian stimulation.

    Science.gov (United States)

    Twigt, John M; Hammiche, Fatima; Sinclair, Kevin D; Beckers, Nicole G; Visser, Jenny A; Lindemans, Jan; de Jong, Frank H; Laven, Joop S E; Steegers-Theunissen, Régine P

    2011-02-01

    Folate is a methyl donor. Availability of folate affects DNA methylation profiles and thereby gene expression profiles. We investigated the effects of low-dose folic acid use (0.4 mg/d) on the ovarian response to mild and conventional ovarian stimulation in women. In a randomized trial among subfertile women, 24 and 26 subjects received conventional and mild ovarian stimulation, respectively. Blood samples were taken during the early follicular phase of the cycle prior to treatment and on the day of human chorionic gonadotropin administration for determination of serum total homocysteine, anti-Müllerian hormone (AMH), estradiol, and folate. Folic acid use was validated by questionnaire and serum folate levels. Preovulatory follicles were visualized, counted, and diameters recorded using transvaginal ultrasound. The relation between folic acid use and ovarian response was assessed using linear regression analysis. Folic acid use modified the ovarian response to ovarian stimulation treatment. The estradiol response was higher in nonfolic acid users receiving conventional treatment [β(interaction) = 0.52 (0.07-0.97); P = 0.03], and this effect was independent of serum AMH levels and the preovulatory follicle count. In the conventional treatment, the mean follicle number was also greater in nonusers compared with the users group (14.1 vs. 8.9, P = 0.03). Low-dose folic acid use attenuates follicular and endocrine responses to conventional stimulation, independent of AMH and follicle count. The nature of this observation suggests that the effect of folic acid is most prominent during early follicle development, affecting immature follicles. Deleterious effects of folate deficiency, like DNA hypomethylation and oxidative stress, can help to explain our observations.

  3. Comparison of ultrasound-guided versus anatomical landmark ...

    African Journals Online (AJOL)

    Background Femoral vein cannulation may be required during major surgery in infants and children and may prove to be life saving under certain conditions. This study compared ultrasound (US)-guided cannulation of the femoral vein in infants with the traditional anatomical landmark-guided technique. Methods Eighty ...

  4. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  5. Transvaginal sonography in abnormal uterine bleeding and correlation to hysteroscopy

    International Nuclear Information System (INIS)

    Saeed, S.; Shah, S.; Ali, H.; Khan, S.; Ehsan, N.; Ahmed, S.Z.

    2017-01-01

    To correlate results of Transvaginal sonography with those of hysteroscopy and biopsy in abnormal uterine bleeding to estimate the accuracy and analytical values of non-invasive transvaginal sonography in abnormal uterine bleeding. Methodology: This cross-sectional Study was carried out at BMCH, Quetta, Balochistan, Pakistan from March 2013 to February 2014 and included 200 patients of abnormal uterine bleeding. Exclusion criteria were pregnancy, virginity, local bleeding of perineal or vaginal origin. Hysteroscopy and biopsy and Transvaginal Ultrasound (TVS) were performed in all. Result: The most common type of bleeding was found to be menorrhagia in 39% while the least common type was postmenopausal bleeding in 9%. Mean endometrial thickness was 11.64 mm and it was noted that at less than 14mm thickness no serious pathology was found. Sensitivity of TVS for endometrial hyperplasia was found to be 66.66% while specificity was 100%. Positive analytical value was 100% while negative value was 100%. Overall sensitivity calculated for TVS was 94.44%, specificity 98.55%, PPV was 81.93% and NPV 98.55%. Conclusion: Sensitivity and specificity of TVS were lower than hysteroscopy and biopsy but the difference was not significant. TVS can be used as first line investigation while hysteroscopy and biopsy may be left for cases of high risk or in those cases where some positive findings could be found on TVS. (author)

  6. Understanding Patient Preference in Female Pelvic Imaging: Transvaginal Ultrasound and MRI.

    Science.gov (United States)

    Sakala, Michelle D; Carlos, Ruth C; Mendiratta-Lala, Mishal; Quint, Elisabeth H; Maturen, Katherine E

    2018-04-01

    Women with pelvic pain or abnormal uterine bleeding may undergo diagnostic imaging. This study evaluates patient experience in transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) and explores correlations between preference and symptom severity. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant prospective study. Fifty premenopausal women with pelvic symptoms evaluated by recent TVUS and MRI and without history of gynecologic cancer or hysterectomy were included. A phone questionnaire used validated survey instruments including Uterine Fibroid Symptoms Quality of Life index, Testing Morbidities Index, and Wait Trade Off for TVUS and MRI examinations. Using Wait Trade Off, patients preferred TVUS over MRI (3.58 vs 2.80 weeks, 95% confidence interval [CI] -1.63, 0.12; P = .08). Summary test utility of Testing Morbidities Index for MRI was worse than for TVUS (81.64 vs 87.42, 95%CI 0.41, 11.15; P = .03). Patients reported greater embarrassment during TVUS than during MRI (P MRI, and greater mental (P = .02) and physical (P = .02) problems after MRI versus TVUS. Subscale correlations showed physically inactive women rated TVUS more negatively (R = -0.32, P = .03), whereas women with more severe symptoms of loss of control of health (R = -0.28, P = .04) and sexual dysfunction (R = -0.30, P = .03) rated MRI more negatively. Women with pelvic symptoms had a slight but significant preference for TVUS over MRI. Identifying specific distressing aspects of each test and patient factors contributing to negative perceptions can direct improvement in both test environment and patient preparation. Improved patient experience may increase imaging value. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Microwave ablation of liver metastases guided by contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, T; Skjoldbye, B O; Nolsoe, C P

    2011-01-01

    The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS).......The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS)....

  8. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  9. Subtypes of Ovarian Cancer and Ovarian Cancer Screening

    Directory of Open Access Journals (Sweden)

    Masafumi Koshiyama

    2017-03-01

    Full Text Available Ovarian cancer is the foremost cause of gynecological cancer death in the developed world, as it is usually diagnosed at an advanced stage. In this paper we discuss current issues, the efficacy and problems associated with ovarian cancer screening, and compare the characteristics of ovarian cancer subtypes. There are two types of ovarian cancer: Type I carcinomas, which are slow-growing, indolent neoplasms thought to arise from a precursor lesion, which are relatively common in Asia; and Type II carcinomas, which are clinically aggressive neoplasms that can develop de novo from serous tubal intraepithelial carcinomas (STIC and/or ovarian surface epithelium and are common in Europe and the USA. One of the most famous studies on the subject reported that annual screening using CA125/transvaginal sonography (TVS did not reduce the ovarian cancer mortality rate in the USA. In contrast, a recent study in the UK showed an overall average mortality reduction of 20% in the screening group. Another two studies further reported that the screening was associated with decreased stage at detection. Theoretically, annual screening using CA125/TVS could easily detect precursor lesions and could be more effective in Asia than in Europe and the USA. The detection of Type II ovarian carcinoma at an early stage remains an unresolved issue. The resolving power of CA125 or TVS screening alone is unlikely to be successful at resolving STICs. Biomarkers for the early detection of Type II carcinomas such as STICs need to be developed.

  10. Subtypes of Ovarian Cancer and Ovarian Cancer Screening.

    Science.gov (United States)

    Koshiyama, Masafumi; Matsumura, Noriomi; Konishi, Ikuo

    2017-03-02

    Ovarian cancer is the foremost cause of gynecological cancer death in the developed world, as it is usually diagnosed at an advanced stage. In this paper we discuss current issues, the efficacy and problems associated with ovarian cancer screening, and compare the characteristics of ovarian cancer subtypes. There are two types of ovarian cancer: Type I carcinomas, which are slow-growing, indolent neoplasms thought to arise from a precursor lesion, which are relatively common in Asia; and Type II carcinomas, which are clinically aggressive neoplasms that can develop de novo from serous tubal intraepithelial carcinomas (STIC) and/or ovarian surface epithelium and are common in Europe and the USA. One of the most famous studies on the subject reported that annual screening using CA125/transvaginal sonography (TVS) did not reduce the ovarian cancer mortality rate in the USA. In contrast, a recent study in the UK showed an overall average mortality reduction of 20% in the screening group. Another two studies further reported that the screening was associated with decreased stage at detection. Theoretically, annual screening using CA125/TVS could easily detect precursor lesions and could be more effective in Asia than in Europe and the USA. The detection of Type II ovarian carcinoma at an early stage remains an unresolved issue. The resolving power of CA125 or TVS screening alone is unlikely to be successful at resolving STICs. Biomarkers for the early detection of Type II carcinomas such as STICs need to be developed.

  11. Magnetic resonance imaging as a diagnostic tool in case of ovarian masses in girls and young women.

    Science.gov (United States)

    Bekiesińska-Figatowska, Monika; Jurkiewicz, Elzbieta; Iwanowska, Beata; Uliasz, Maria; Romaniuk-Doroszewska, Anna; Bragoszewska, Hanna; Ceran, Alicja; Olszewski, Andrzej

    2007-05-01

    Gynecological examination and transvaginal ultrasound are difficult or impossible in girls and young women who have not started their sexual life. CT is not a method of choice in this age group because of the ionizing radiation and iodine-containing contrast media. MRI is chosen then. Pelvic MRI was performed in 15 patients aged 9-19 years with suspected ovarian mass after they had had unclear gynecological and sonographic examinations. 1.5 T MRI systems were used. SE,T(F)SE and SPIR sequences were applied in T1- and T2-weighted images in three planes. Contrast media were administered in 7 patients. In a group of 3 girls with acute abdominal pain, polycystic ovaries, ovarian hemorrhagic cyst, and fibroma of the ovary were diagnosed. In a group of 11 patients with chronic abdominal pain, dermoid cysts of the ovaries were found in 7 cases, in one bilateral and accompanied by ectopic kidney. In 2 patients, serous cysts were diagnosed. In 2 cases an ovarian origin of the mass was excluded: multilocular cystic lesion in the presacral region and a hydatid mole were revealed. A neoplastic ovarian mass was diagnosed in a girl with increasing circumference of the abdomen. The accuracy of MRI in localizing lesions was 100%. Its accuracy in precisely characterizing lesions was 83.3%. Magnetic resonance imaging, with its noninvasiveness, high spatial resolution, and tissue specificity, is a method of choice in the diagnosis or exclusion of ovarian pathology in children and adolescents.

  12. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  13. Prolapse Recurrence after Transvaginal Mesh Removal.

    Science.gov (United States)

    Rawlings, Tanner; Lavelle, Rebecca S; Coskun, Burhan; Alhalabi, Feras; Zimmern, Philippe E

    2015-11-01

    We determined the rate of pelvic organ prolapse recurrence after transvaginal mesh removal. Following institutional review board approval a longitudinally collected database of women undergoing transvaginal mesh removal for complications after transvaginal mesh placement with at least 1 year minimum followup was queried for pelvic organ prolapse recurrence. Recurrent prolapse was defined as greater than stage 1 on examination or the need for reoperation at the site of transvaginal mesh removal. Outcome measures were based on POP-Q (Pelvic Organ Prolapse Quantification System) at the last visit. Patients were grouped into 3 groups, including group 1--recurrent prolapse in the same compartment as transvaginal mesh removal, 2--persistent prolapse and 3--prolapse in a compartment different than transvaginal mesh removal. Of 73 women 52 met study inclusion criteria from 2007 to 2013, including 73% who presented with multiple indications for transvaginal mesh removal. The mean interval between insertion and removal was 45 months (range 10 to 165). Overall mean followup after transvaginal mesh removal was 30 months (range 12 to 84). In group 1 (recurrent prolapse) the rate was 15% (6 of 40 patients). Four women underwent surgery for recurrent prolapse at a mean 7 of months (range 5 to 10). Two patients elected observation. The rate of persistent prolapse (group 2) was 23% (12 of 52 patients). Three women underwent prolapse reoperation at a mean of 10 months (range 8 to 12). In group 3 (de novo/different compartment prolapse) the rate was 6% (3 of 52 patients). One woman underwent surgical repair at 52 months. At a mean 2.5-year followup 62% of patients (32 of 52) did not have recurrent or persistent prolapse after transvaginal mesh removal and 85% (44 of 52) did not undergo any further procedure for prolapse. Specifically for pelvic organ prolapse in the same compartment as transvaginal mesh removal 12% of patients had recurrence, of whom 8% underwent prolapse repair

  14. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  15. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  16. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  17. PET/CT scanning guided intensity-modulated radiotherapy in treatment of recurrent ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xue-lian, E-mail: duxuelian23800@yahoo.com.cn [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China); Jiang, Tao, E-mail: melody23800@yahoo.com.cn [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China); Sheng, Xiu-gui, E-mail: jnsd2000@yahoo.cn [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China); Li, Qing-shui, E-mail: lqs1966@126.com [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China); Wang, Cong, E-mail: jnwc1981@hotmail.com [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China); Yu, Hao, E-mail: jnyh2200@sina.com [Department of Gynecologic Oncology, Shandong Cancer Hospital, Jinan 250117 (China); Shandong Academy of Medical Science, Jinan 250012 (China)

    2012-11-15

    Objective: This study was undertaken to evaluate the clinical contribution of positron emission tomography using {sup 18}F-fluorodeoxyglucose and integrated computer tomography (FDG-PET/CT) guided intensity-modulated radiotherapy (IMRT) for treatment of recurrent ovarian cancer. Materials and methods: Fifty-eight patients with recurrent ovarian cancer from 2003 to 2008 were retrospectively studied. In these patients, 28 received PET/CT guided IMRT (PET/CT-IMRT group), and 30 received CT guided IMRT (CT-IMRT group). Treatment plans, tumor response, toxicities and survival were evaluated. Results: Changes in GTV delineation were found in 10 (35.7%) patients based on PET-CT information compared with CT data, due to the incorporation of additional lymph node metastases and extension of the metastasis tumor. PET/CT guided IMRT improved tumor response compared to CT-IMRT group (CR: 64.3% vs. 46.7%, P = 0.021; PR: 25.0% vs. 13.3%, P = 0.036). The 3-year overall survival was significantly higher in the PET-CT/IMRT group than control (34.1% vs. 13.2%, P = 0.014). Conclusions: PET/CT guided IMRT in recurrent ovarian cancer patients improved the delineation of GTV and reduce the likelihood of geographic misses and therefore improve the clinical outcome.

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  19. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  20. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    Directory of Open Access Journals (Sweden)

    Zolnierczyk P

    2015-05-01

    Full Text Available Piotr Zolnierczyk, Krzysztof Cendrowski, Wlodzimierz Sawicki Department of Obstetrics, Gynecology and Oncology, 2nd Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland Abstract: This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38, congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. Keywords: ovarian cyst puncture, hysteroscopy, ultrasound guided puncture, transfundal cyst puncture, vaginoscopy 

  1. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  2. Ultrasound- versus palpation-guided injection of corticosteroid for plantar fasciitis: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Zonghuan Li

    Full Text Available It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis.Databases (MEDLINE, Cochrane library and EMBASE and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS, tenderness threshold (TT, heel tenderness index (HTI, response rate, plantar fascia thickness (PFT, hypoechogenicity and heel pad thickness (HPT. The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE system was used to assess the quality of evidence.Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI.Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research.

  3. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    Science.gov (United States)

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  4. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  5. Interventional prevention of ovarian hyperstimulation syndrome in infertility patients with polycystic ovaries syndrome

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Chen Xia; Cai Kuan; Wang Weiqun; Zhu Junlin

    2008-01-01

    Objective: To assess the efficacy of aspiration of small follicles(ASF) guided by trans-vaginal ultra- sound (TVS) in preventing moderate and severe ovarian hyperstimulation syndrome (OHSS) in women with polycystic ovaries syndrome (PCOS). Methods: ASF was undertaken by trans-vaginally during artificial cycles in 25 women with PCOS who had early signs of OHSS during the early period of the cycle according to the ovaries and follicles detected by TVS. Small follicles(≤ 12 mm in diameter) were aspirated at the early period of gonadotropin therapy according to the follicle testing, three or less excellent follicles were reserve. All the patients were followed up for symptoms and signs of OHSS. Results: None of the patients developed moderate or severe OHSS. Successful intrauterine pregnancy were found in 7 cases (28%). Conclusion: ASF after gonadotropin injections is of significance to prevent moderate and severe OHSS and obtain a higher pregnancy rate in susceptible patients with PCOS during the early period of the cycles. Time of ASF is the main factor to prevent OHSS. TVS may be an important tool in the detection of early period of follicles development. (authors)

  6. Postmenopausal palpable ovary and ovarian cancer.

    Science.gov (United States)

    Gojnić, M; Branković, M; Maksimović, M; Parapid, B; Dugalić, V; Jeremić, K; Gutić, B

    2011-01-01

    Ultrasound (US) examination is a much more reliable method for evaluation of potential ovarian cancer risk than gynecologic palpation. The aim of our study was to analyze the US characteristics of patients with palpable ovaries in light of potential for malignancy. We analyzed 70 women ten years after menopause without increased CA 125 values. They underwent clinical and US exams (abdominal and transvaginal ultrasound), with special emphasis on US Doppler exam. Bimanuel gynecological examination showed palpable ovaries in 14 patients (palpable ovary group), and the remaining 56 patients were defined as the control group. US showed increased dimensions of palpable ovaries. Atypical follicular activity, deviation from verticalization, atypical ovaries and hyperechogenic punctations classified under germ cell cysts occurred statistically significantly more often in the palpable ovary group. Doppler flow showed pathological vascularization in five patients with palpable ovaries and the estrogen level was increased. After four to six months in these five patients we found a mild increase of estrogen levels and higher Doppler abnormality. Six months later, two patients had irregular bleeding and underwent surgical treatment. Every adnexal mass after menopausis demands special attention. Bimanuel gynecological exams should be used liberally. It is necessary to follow the dimensions of the ovary, describe the echostructure, as well as the edges of the ovary and other anatomical structures. Doppler flow measurement and estrogen levels are predictive and give more information. Controls should be in three to six month intervals in order to make a decision for surgical treatment.

  7. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  8. Two-dimensional power Doppler-three-dimensional ultrasound imaging of a cesarean section dehiscence with utero-peritoneal fistula: a case report

    Directory of Open Access Journals (Sweden)

    Royo Pedro

    2009-01-01

    Full Text Available Abstract Introduction An imaging diagnosis after an iterative cesarean delivery is reviewed demonstrating a fine ultrasound-pathologic correlation. Case presentation A 33-year-old woman (G3, P3 presented referring intense dysmenorrhea and intermenstrual spotting since her third cesarean delivery, 1 year before. A cesarean section dehiscence with utero-peritoneal fistula was diagnosed by transvaginal ultrasound. Conclusion We can conclude that transvaginal two-dimensional power Doppler and three-dimensional ultrasound are highly accurate in detecting cesarean section dehiscence and uterine fistula.

  9. The Distribution of Stroma and Antral Follicles Differs between Insulin-Resistance and Hyperandrogenism-Related Polycystic Ovarian Syndrome

    Directory of Open Access Journals (Sweden)

    Carlo Alviggi

    2017-05-01

    Full Text Available IntroductionAlthough insulin resistance plays an important pathogenetic role in polycystic ovary syndrome (PCOS, no correlation between ultrasound PCOS pattern and insulin resistance has yet been reported. The aim of this retrospective observational study was to assess whether the ovarian ultrasonographic parameter differed between PCOS women with insulin resistance and those with a hyperandrogenic profile.Materials and methodsWomen who fulfilled the Rotterdam criteria for PCOS were retrospectively studied. Anthropometric, biochemical, and clinical data were recorded. Women were divided into two groups based on specific transvaginal ultrasound parameters: subjects with more than half of the follicles measuring between 5 and 9 mm in diameter, an ultrasonographic determined stroma/total area (S/A > 0.34 and a “necklace” sign of antral follicles (Group A; and subjects with more than half of the antral follicles measuring between 2 and 4 mm in diameter, an S/A ≤ 0.34; no “necklace” sign but ubiquitously distributed follicles determined by ultrasound (Group B. The association between these ultrasound patterns and the presence of insulin resistance was also evaluated.ResultsSeventy-eight patients were enrolled: 33 with ultrasound sound pattern A and 45 with pattern B. The latter pattern had a sensitivity of 88% and a specificity of 78% in predicting PCOS women with insulin resistance. There were no differences in age, Ferriman–Gallwey score, and serum gonadotropin or androgen levels between the two groups. Body mass index, the waist-to-hip ratio, and homeostasis model assessment were significantly higher in group B than in group A (p < 0.05. Conversely, sex hormone binding globulin levels and ovarian volume were significantly higher in group A (p < 0.05. Insulin resistance was more frequent in group B than in group A (36/41, 87.8% versus 7/32, 21.8%; p < 0.05.ConclusionThese results suggest that insulin resistance

  10. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  11. Ultrasound-guided antegrade pyelography of renal transplants

    International Nuclear Information System (INIS)

    Wernecke, K.; Heckemann, R.; Rehwald, U.; Ringert, R.H.; Essen Univ.

    1983-01-01

    The indications for, and technique of, ultrasound-guided antegrade pyelography of renal transplants are illustrated by eight patients. Because of the detailed anatomical information which the antegrade method provides, it is superior to other diagnostic methods for the investigation of ureteric obstruction or fistulae. The severity of renal pelvis dilatation as shown by sonography must not be taken as a criterian for the grade of obstruction, since transplants may show dilated collecting systems, even in the absence of obstruction. In our view, real time sonography with a suitable probe provides the best means of achieving successful puncture of the renal pelvis. The combination of ultrasound-guided puncture and radiological contrast examination of the ureter is the best diagnostic method available and lead, in all eight cases, to immediate and definitive treatment. (orig.)

  12. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  13. Strategies to diagnose ovarian cancer: new evidence from phase 3 of the multicentre international IOTA study.

    Science.gov (United States)

    Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D

    2014-08-12

    To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917-0.942), 0.918 (0.905-0.930), 0.914 (0.886-0.936) and 0.875 (0.853-0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90-96%, specificity 74-79% and diagnostic odds ratio (DOR) 32.8-50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6-75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference.

  14. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  15. Ratio of ovarian stroma and total ovarian area by ultrasound in prediction of hyperandrogenemia in reproductive-aged Thai women with polycystic ovary syndrome: a diagnostic test.

    Science.gov (United States)

    Leerasiri, Pichai; Wongwananuruk, Thanyarat; Rattanachaiyanont, Manee; Indhavivadhana, Suchada; Techatraisak, Kitirat; Angsuwathana, Surasak

    2015-02-01

    To evaluate the performance of ovarian stromal area to total ovarian area (S/A) ratio for the prediction of biochemical hyperandrogenism in Thai women with polycystic ovary syndrome (PCOS). A cross-sectional study was performed in 222 reproductive-aged Thai women with PCOS attending the Gynecologic Endocrinology Unit (GEU), Department of Obstetrics and Gynecology, Faculty of Medicine Siriraj Hospital from May 2007 to January 2009. The patients were interviewed for medical history and examined for anthropometry and clinical hyperandrogenism. Venous blood samples were obtained for androgen profiles. An ovarian ultrasonogram was obtained via transvaginal or transrectal ultrasonography. The prevalences of clinical and biochemical hyperandrogenism were 48.6% and 81.1%, respectively. The S/A ratio at a cut-off point of 0.33 had modest predictability for hyperandrogenism, namely, 0.537 area under the receiver-operator curve, 36.6% sensitivity, 72.1% specificity, 83.8% positive predictive value (PPV) and 20.9% negative predictive value (NPV). The combination of clinical hyperandrogenism and S/A ratio improved the predictability for biochemical hyperandrogenism, with sensitivity, specificity, PPV and NPV of 72.1%, 58.1%, 87.8% and 33.3%, respectively. The S/A ratio alone is not a good predictor for biochemical hyperandrogenism in Thai PCOS women attending GEU for menstrual dysfunction. The combination of S/A ratio and clinical hyperandrogenism has better performance than the S/A ratio alone to predict biochemical hyperandrogenism. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  16. Ultrasound-guided central venous access using Google Glass.

    Science.gov (United States)

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  18. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  19. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  20. Contrast-enhanced ultrasound-guided radiofrequency ablation in inconspicuous hepatocellular carcinoma on B-mode ultrasound.

    Science.gov (United States)

    Kim, Eui Joo; Kim, Yun Soo; Shin, Seung Kak; Kwon, Oh Sang; Choi, Duck Joo; Kim, Ju Hyun

    2017-11-01

    B-mode ultrasound (US) has difficulty targeting small hepatocellular carcinomas (HCCs) with poor conspicuity during radiofrequency ablation (RFA). Contrast-enhanced ultrasound (CEUS) can improve visualization of small or inconspicuous HCCs. This study was conducted to evaluate the effectiveness of CEUS-guided RFA electrode insertion during the arterial phase in inconspicuous HCCs. Ninety-three treatment-naïve HCCs from 80 patients treated with RFA from August 2012 to December 2014 were retrospectively reviewed. Seventy-five HCCs from 65 patients underwent B-mode US-guided RFA, and 15 HCCs from 14 patients that were inconspicuous on B-mode US underwent CEUS-guided RFA during the arterial phase after injection of sulfur hexafluoride microbubbles (SonoVue®). Technical success was assessed by contrast-enhanced computed tomography within 1 week and 3 months after the procedure. The mean size of HCCs treated with CEUS-guided RFA was smaller than that of HCCs treated with B-mode US-guided RFA (1.17±0.36 vs. 1.63±0.55 cm, p=0.003). Technical success rates of CEUS-guided RFA within 1 week and 3 months were 100% (15/15) and 93.3% (14/15), respectively. Technical success rates of B-mode US-guided RFA were 97.3% (73/75) and 94.5% (69/73), respectively. CEUS-guided RFA is highly efficacious for ablation of very small and inconspicuous HCCs.

  1. Review of magnetic resonance-guided focused ultrasound in the treatment of uterine fibroids

    Directory of Open Access Journals (Sweden)

    Pedro Felipe Magalhães Peregrino

    Full Text Available Uterine leiomyoma is the most frequently occurring solid pelvic tumor in women during the reproductive period. Magnetic resonance-guided high-intensity focused ultrasound is a promising technique for decreasing menorrhagia and dysmenorrhea in symptomatic women. The aim of this study is to review the role of Magnetic resonance-guided high-intensity focused ultrasound in the treatment of uterine fibroids in symptomatic patients. We performed a review of the MEDLINE and Cochrane databases up to April 2016. The analysis and data collection were performed using the following keywords: Leiomyoma, High-Intensity Focused Ultrasound Ablation, Ultrasonography, Magnetic Resonance Imaging, Menorrhagia. Two reviewers independently performed a quality assessment; when there was a disagreement, a third reviewer was consulted. Nineteen studies of Magnetic resonance-guided high-intensity focused ultrasound-treated fibroid patients were selected. The data indicated that tumor size was reduced and that symptoms were improved after treatment. There were few adverse effects, and they were not severe. Some studies have reported that in some cases, additional sessions of Magnetic resonance-guided high-intensity focused ultrasound or other interventions, such as myomectomy, uterine artery embolization or even hysterectomy, were necessary. This review suggests that Magnetic resonance-guided high-intensity focused ultrasound is a safe and effective technique. However, additional evidence from future studies will be required before the technique can be recommended as an alternative treatment for fibroids.

  2. Level set segmentation of bovine corpora lutea in ex situ ovarian ultrasound images

    Directory of Open Access Journals (Sweden)

    Adams Gregg P

    2008-08-01

    Full Text Available Abstract Background The objective of this study was to investigate the viability of level set image segmentation methods for the detection of corpora lutea (corpus luteum, CL boundaries in ultrasonographic ovarian images. It was hypothesized that bovine CL boundaries could be located within 1–2 mm by a level set image segmentation methodology. Methods Level set methods embed a 2D contour in a 3D surface and evolve that surface over time according to an image-dependent speed function. A speed function suitable for segmentation of CL's in ovarian ultrasound images was developed. An initial contour was manually placed and contour evolution was allowed to proceed until the rate of change of the area was sufficiently small. The method was tested on ovarian ultrasonographic images (n = 8 obtained ex situ. A expert in ovarian ultrasound interpretation delineated CL boundaries manually to serve as a "ground truth". Accuracy of the level set segmentation algorithm was determined by comparing semi-automatically determined contours with ground truth contours using the mean absolute difference (MAD, root mean squared difference (RMSD, Hausdorff distance (HD, sensitivity, and specificity metrics. Results and discussion The mean MAD was 0.87 mm (sigma = 0.36 mm, RMSD was 1.1 mm (sigma = 0.47 mm, and HD was 3.4 mm (sigma = 2.0 mm indicating that, on average, boundaries were accurate within 1–2 mm, however, deviations in excess of 3 mm from the ground truth were observed indicating under- or over-expansion of the contour. Mean sensitivity and specificity were 0.814 (sigma = 0.171 and 0.990 (sigma = 0.00786, respectively, indicating that CLs were consistently undersegmented but rarely did the contour interior include pixels that were judged by the human expert not to be part of the CL. It was observed that in localities where gradient magnitudes within the CL were strong due to high contrast speckle, contour expansion stopped too early. Conclusion The

  3. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  4. Proactive error analysis of ultrasound-guided axillary brachial plexus block performance.

    LENUS (Irish Health Repository)

    O'Sullivan, Owen

    2012-07-13

    Detailed description of the tasks anesthetists undertake during the performance of a complex procedure, such as ultrasound-guided peripheral nerve blockade, allows elements that are vulnerable to human error to be identified. We have applied 3 task analysis tools to one such procedure, namely, ultrasound-guided axillary brachial plexus blockade, with the intention that the results may form a basis to enhance training and performance of the procedure.

  5. Use of dynamic 3-dimensional transvaginal and transrectal ultrasonography to assess posterior pelvic floor dysfunction related to obstructed defecation.

    Science.gov (United States)

    Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader

    2014-02-01

    New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and

  6. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial.

    NARCIS (Netherlands)

    Rahusen, F.D.; Bremers, A.J.A.; Fabry, H.F.; Taets van Amerongen, A.H.; Boom, R.P.; Meijer, S.

    2002-01-01

    BACKGROUND: The wire-guided excision of nonpalpable breast cancer often results in tumor resections with inadequate margins. This prospective, randomized trial was undertaken to investigate whether intraoperative ultrasound (US) guidance enables a better margin clearance than the wire-guided

  7. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    Science.gov (United States)

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  8. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    Science.gov (United States)

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  9. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  10. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  11. Transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions%经阴道彩色多普勒超声在子宫内膜病变诊断的应用价值

    Institute of Scientific and Technical Information of China (English)

    高鸣

    2015-01-01

    目的 探讨经阴道彩色多普勒超声在子宫内膜病变诊断中的应用价值,总结其应用经验.方法 对90例不规则阴道流血患者行经阴道彩色多普勒超声检查,分析其超声影像学资料,并将超声检查结果与诊刮以及患者术后病理诊断结果相对照.结果 本研究90例患者经阴道彩色多普勒超声检查确诊86例,其中子宫内膜增生36例、子宫内膜息肉42例,子宫内膜癌8例,确诊率为95.64%;漏诊4例,漏诊率为4.36%,其中1例子宫内膜癌病变,3例子宫内膜增生病变.结论 经阴道彩色多普勒超声检查子宫内膜病变操作简便、准确性高,超声检查时应注意测量子宫内膜厚度,观察内膜形态、内膜与肌层的关系、内膜回声特点以及子宫内膜内血流情况及阻力指数,作为诊断子宫内膜病变的重要检查方法,还需要结合患者的临床表现及其他影像学检查手段,以提高其确诊率.%Objective To investigate the application value of transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions,and summarize the application experience.Methods Ninety patients with irregular vaginal bleeding underwent transvaginal color Doppler ultrasound examination,the ultrasound image data were analyzed,and the ultrasonic inspection results and curettage and postoperative pathological diagnosis results were compared.Results Among the 90 cases,86 cases were diagnosed by transvaginal color Doppler ultrasound,of which 36 cases of endometrial hyperplasia,42 cases of endometrial polyps,endometrial carcinoma in 8 cases,the diagnosis rate was 95.64% ; 4 cases of missed diagnosis,the missed diagnosis rate was 4.36%,in which l case of endometrial carcinoma lesions,3 cases of uterus hyperplasia lesions.Conclusions Transvaginal color Doppler ultrasonography for endometrial lesions has simple operation,high accuracy,we should pay attention to measure the thickness of endometrium,endometrial morphology

  12. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  13. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    Science.gov (United States)

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  15. Pure transvaginal excision of mesh erosion involving the bladder.

    Science.gov (United States)

    Firoozi, Farzeen; Goldman, Howard B

    2013-06-01

    We present a pure transvaginal approach to the removal of eroded mesh involving the bladder secondary to placement of transvaginal mesh for management of pelvic organ prolapse (POP) using a mesh kit. Although technically challenging, we demonstrate the feasibility of a purely transvaginal approach, avoiding a potentially more morbid transabdominal approach. The video presents the surgical technique of pure transvaginal excision of mesh erosion involving the bladder after mesh placement using a prolapse kit was performed. This video shows that purely transvaginal removal of mesh erosion involving the bladder can be done safely and is feasible.

  16. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Ultrasound guided local steroid injection versus extracorporeal ...

    African Journals Online (AJOL)

    Nayera Saber

    2011-12-17

    Dec 17, 2011 ... Results: There was a statistically significant reduction in plantar fascia .... Several previous studies evaluate the effects of either local ... The choice of ultrasound guided technique of steroid injection was related to the accuracy of application and supe- ..... chronic proximal plantar fasciitis: a meta analysis.

  18. Ultrasound-guided removal of Implanon devices.

    LENUS (Irish Health Repository)

    Persaud, T

    2008-11-01

    Our study has shown that ultrasound-guided localisation and removal of Implanon rods is safe, practical and highly successful. Over a 4-year period, 119 patients had successful, uncomplicated removal of their subdermal devices.The technique is particularly useful for removal of the device when it is not palpable or when an attempt at removal of a palpable device has not been successful.

  19. Ultrasound Guided Nerve Root Injection in Patients with Cervical Spondylytic Radicular Pain

    Directory of Open Access Journals (Sweden)

    LT Choong

    2009-05-01

    Full Text Available Selective cervical nerve root injection using a mixture of corticosteroid and lignocaine is a treatment option for managing cervical radiculopathic pain. The procedure is usually performed under image guided fluoroscopy or Computerized Tomograhy. Ultrasound-guided cervical nerve root block does not expose the patients and personnel to radiation. During injection, the fluid is mostly visualized in a real-time fashion. This retrospective study reviewed the effectiveness of ultrasound in guiding cervical peri-radicular injection for pain relief in patients with recalcitrant cervical radiculopathy. There were no complications reported in this series.

  20. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    Directory of Open Access Journals (Sweden)

    Abdallah El-Sayed Allam

    2018-01-01

    Full Text Available Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.

  1. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  2. Anterior colporrhaphy versus transvaginal mesh for pelvic-organ prolapse.

    Science.gov (United States)

    Altman, Daniel; Väyrynen, Tapio; Engh, Marie Ellström; Axelsen, Susanne; Falconer, Christian

    2011-05-12

    The use of standardized mesh kits for repair of pelvic-organ prolapse has spread rapidly in recent years, but it is unclear whether this approach results in better outcomes than traditional colporrhaphy. In this multicenter, parallel-group, randomized, controlled trial, we compared the use of a trocar-guided, transvaginal polypropylene-mesh repair kit with traditional colporrhaphy in women with prolapse of the anterior vaginal wall (cystocele). The primary outcome was a composite of the objective anatomical designation of stage 0 (no prolapse) or 1 (position of the anterior vaginal wall more than 1 cm above the hymen), according to the Pelvic Organ Prolapse Quantification system, and the subjective absence of symptoms of vaginal bulging 12 months after the surgery. Of 389 women who were randomly assigned to a study treatment, 200 underwent prolapse repair with the transvaginal mesh kit and 189 underwent traditional colporrhaphy. At 1 year, the primary outcome was significantly more common in the women treated with transvaginal mesh repair (60.8%) than in those who underwent colporrhaphy (34.5%) (absolute difference, 26.3 percentage points; 95% confidence interval, 15.6 to 37.0). The surgery lasted longer and the rates of intraoperative hemorrhage were higher in the mesh-repair group than in the colporrhaphy group (Pmesh-repair group and 0.5% in the colporrhaphy group (P=0.07), and the respective rates of new stress urinary incontinence after surgery were 12.3% and 6.3% (P=0.05). Surgical reintervention to correct mesh exposure during follow-up occurred in 3.2% of 186 patients in the mesh-repair group. As compared with anterior colporrhaphy, use of a standardized, trocar-guided mesh kit for cystocele repair resulted in higher short-term rates of successful treatment but also in higher rates of surgical complications and postoperative adverse events. (Funded by the Karolinska Institutet and Ethicon; ClinicalTrials.gov number, NCT00566917.).

  3. Ultrasound-Guided Percutaneous Dilational Tracheostomy: A Systematic Review of Randomized Controlled Trials and Meta-Analysis.

    Science.gov (United States)

    Gobatto, André L N; Besen, Bruno A M P; Cestari, Mino; Pelosi, Paolo; Malbouisson, Luiz M S

    2018-01-01

    Percutaneous dilational tracheostomy (PDT) is a common and increasingly used procedure in the intensive care unit (ICU). It is usually performed with bronchoscopy guidance. Ultrasound has emerged as a useful tool in order to assist PDT, potentially improving its success rate and reducing procedural-related complications. To investigate whether the ultrasound-guided PDT is equivalent or superior to the bronchoscopy-guided or anatomical landmarks-guided PDT with regard to procedural-related and clinical complications. A systematic review of randomized clinical trials was conducted comparing an ultrasound-guided PDT to the control groups (either a bronchoscopy-guided PDT or an anatomical landmark-guided PDT) in patients undergoing a PDT in the ICU. The primary outcome was the incidence of major procedural-related and clinical complication rates. The secondary outcome was the incidence of minor complication rates. Random-effect meta-analyzes were used to pool the results. Four studies fulfilled the inclusion criteria and they were analyzed. The studies included 588 participants. There were no differences in the major complication rates between the patients who were assigned to the ultrasound-guided PDT when compared to the control groups (pooled risk ratio [RR]: 0.48; 95% confidence interval [CI]: 0.13-1.71, I 2 = 0%). The minor complication rates were not different between the groups, but they had a high heterogeneity (pooled RR: 0.49; 95% CI 0.16-1.50; I 2 = 85%). The sensitivity analyzes that only included the randomized controlled trials that used a landmark-guided PDT as the control group showed lower rates of minor complications in the ultrasound-guided PDT group (pooled RR: 0.55; 95% CI: 0.31-0.98, I 2 = 0%). The ultrasound-guided PDT seems to be safe and it is comparable to the bronchoscopy-guided PDT regarding the major and minor procedural-related or clinical complications. It also seems to reduce the minor complications when compared to the anatomical

  4. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    International Nuclear Information System (INIS)

    Wang Yang; Wang Wei; Wang Longxia; Wang Junyan; Tang Jie

    2011-01-01

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  5. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yang [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Wei, E-mail: wangyang301301@yahoo.com.cn [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Longxia; Wang Junyan; Tang Jie [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2011-07-15

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  6. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  7. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    Science.gov (United States)

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  8. Efeitos da Histerectomia Total Abdominal sobre o Fluxo Sangüíneo Ovariano Effect of Total Abdominal Hysterectomy on Ovarian Blood Supply

    Directory of Open Access Journals (Sweden)

    Eliana Aguiar Petri Nahás

    2002-06-01

    Full Text Available Objetivo: avaliar os efeitos da histerectomia total abdominal (HTA sobre o fluxo sangüíneo ovariano, em mulheres no menacme, por meio da dopplervelocimetria e ultra-sonografia transvaginal. Métodos: estudo prospectivo no qual foram incluídas 61 mulheres, com idade igual ou inferior a 40 anos. As pacientes foram divididas em dois grupos: G1, com 31 pacientes submetidas à HTA, e G2, com 30 mulheres normais não submetidas à cirurgia. Somente foram incluídas pacientes eumenorréicas, ovulatórias, não-obesas ou fumantes, sem cirurgias ou doenças ovarianas prévias. Avaliou-se o fluxo sangüíneo das artérias ovarianas, inicialmente e aos 6 e 12 meses, pelo índice de pulsatilidade (IP na dopplervelocimetria, e o volume ovariano pela ultra-sonografia transvaginal (US. Para análise estatística empregou-se teste t pareado, análise de perfil, teste de Friedman e teste de Mann-Whitney. Resultados: na comparação estatística inicial os grupos foram homogêneos quanto às características epidemiológicas e quanto aos demais parâmetros avaliados neste estudo. Nas pacientes submetidas à histerectomia, observaram-se aos 6 e 12 meses aumento do volume ovariano ao US e diminuição do IP avaliado pela dopplervelocimetria (pPurpose: to evaluate the effect of total abdominal hysterectomy on ovarian blood supply in women in reproductive age, using transvaginal color Doppler. Methods: a prospective study was carried out on 61 40-year-old or younger women. They were divided into two groups: G1, 31 patients submitted to hysterectomy, and G2, 30 normal women. Criteria of inclusion: normal ovarian function at baseline, normal body weight, without expasure to tobacco, no history of laparotomy or ovarian pathology. The pulsatility index (PI of ovarian arteries determined by Doppler and the transvaginal ultrasonographic measurement of the ovarian volume were performed at three moments: baseline, 6 and 12 months. Results: at baseline the groups were

  9. Transvaginal Resection of an Infected Sacrocolpopexy Mesh by Single-Port Trocar.

    Science.gov (United States)

    Schaub, Marie; Lecointre, Lise; Faller, Emilie; Boisramé, Thomas; Baldauf, Jean-Jacques; Akladios, Cherif Youssef

    Laparoscopy using a single port improves morbidity while keeping the same level of requirement. This technique has been evaluated in gynecology for salpingectomy, ovarian surgery, and hysterectomy. Here, the authors illustrate a new use of a single port using the transvaginal approach. Case report (Canadian Task Force classification III). Tertiary referral center in Strasbourg, France. Woman age 59 years. Single-port platform used in the transvaginal approach for resection of sacrocolpopexy mesh. The local institutional review board approved the video. A 59-year-old woman suffering from insulin-dependent diabetes and a tobacco user had 2 laparoscopic sacrocolpopexies for recurrent rectocele, the first in 2007 and the second in 2012. The sequences were marked by mesh erosion and granuloma in the vagina, requiring its surgical excision in 2016. The patient was then symptomatic, with an increasingly foul-smelling vaginal discharge with recurrent mesh erosion. Magnetic resonance imaging showed an abscess formation along the length of the mesh to the promontory. The patient then underwent surgery, realized under probabilistic antibiotic therapy, consisting of complete excision of the sacrocolpopexy mesh by the transvaginal approach. After putting the single-port trocar (GelPoint; Applied Medical, Rancho Santa Margarita, CA) into the vagina and obtaining distension with the insufflator (AirSeal; Conmed, Utica, NY), classic laparoscopic instruments were introduced by the single-port trocar. The mesh was entirely resected in the retroperitoneal space. Mesh was again used because the exposed space is almost always surrounded by loose granulation tissue that facilitates dissection and also prevents injury to adjacent structures such as bladder, rectum, and peritoneum. Moreover, the opening of adjacent structures will manifest gas leaks and, consequently, loss of the pneumovagina. At the end of procedure, the vagina is not closed to permit optimal drainage with a multitubular

  10. Mechanical obstruction to ventilation from an ovarian cyst during pregnancy.

    Science.gov (United States)

    Beng, D T; Choon, L T

    1991-05-01

    This report documents the danger of the gravid uterus fixing a large ovarian cyst in a position disadvantageous to diaphragmatic excursion and thereby obstructing ventilation. A 34-year-old pregnant patient presented at 18 weeks amenorrhoea with a large ovarian cyst. She gave a history of exertional dyspnoea and orthopnoea. Clinical examination revealed a grossly enlarged abdomen and a respiratory rate of 28 breaths.min-1. Intraoperatively, ventilation was markedly impaired resulting in cyanosis and bradycardia. This was relieved by drainage of the ovarian cyst. A left lateral tilt with manual traction on the tumour may have avoided this problem. Should the above measures be inadequate, immediate drainage of the cyst is essential. Severe respiratory distress may require ultrasound-guided, percutaneous, aspiration of the cyst preoperatively. However, as in this patient, the absence of gross signs of respiratory failure does not preclude acute ventilatory failure after induction of anaesthesia.

  11. Intraoperative Ultrasound-Guided Removal of Retained Mini Sling Anchor Causing Vaginal Pain: A Case Report.

    Science.gov (United States)

    Almassi, Nima; Goldman, Howard B

    2016-01-01

    Since the introduction of the tension-free vaginal tape, the surgical management of female stress urinary incontinence has undergone a dramatic shift toward synthetic midurethral slings (MUSs). The evolution of the MUS has led to the development of the single incision mini sling (SIMS), a minimally invasive procedure that can be performed under local anesthesia. Complications arising after SIMS placement parallel those of the traditional MUS, including pelvic pain, dyspareunia, and mesh erosion. The patient in this case presented with persistent pelvic pain due to a retained SIMS anchor after having previously undergone SIMS placement and subsequent transvaginal exploration with mesh removal. We report the use of intraoperative ultrasound for identification and removal of the retained SIMS anchor.

  12. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis.

    Science.gov (United States)

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-09-07

    The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups' results. Findings from RWC-TVS or DCBE were compared with histological results. The severity of experienced pain severity through RWC-TVS or DCBE was assessed by an analogue scale of 10 cm. In total, 110 in 198 women were confirmed to have endometriosis nodules in the bowel by laparoscopy as well as histopathology. For bowel endometriosis diagnosis, DCBE and RWC-TVS demonstrated sensitivities of 96.4% and 88.2%, specificities of 100% and 97.3%, positive prediction values of 100% and 98.0%, negative prediction values of 98.0% and 88.0%, accuracies of 98.0% and 92.4%, respectively. DCBE was related to more tolerance than RWC-TVS. RWC-TVS and DCBE demonstrated similar accuracies in the bowel endometriosis diagnosis; however, patients showed more tolerance for RWC-TVS than those with DCBE. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  14. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    Science.gov (United States)

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  15. Ovarian morphology is associated with insulin resistance in women with polycystic ovary syndrome: a cross sectional study.

    Science.gov (United States)

    Reid, Sara Pittenger; Kao, Chia-Ning; Pasch, Lauri; Shinkai, Kanade; Cedars, Marcelle I; Huddleston, Heather G

    2017-01-01

    Polycystic ovary syndrome (PCOS) is a very common disorder well known to be associated with insulin resistance and metabolic disease. Insulin resistance is likely involved in the promotion of the PCOS reproductive phenotype and may mediate some of the ovarian morphology seen in the disorder. The phenotype of each individual woman with PCOS can vary widely as can her metabolic risk. This is a cross-sectional study of patients seen in a multidisciplinary PCOS clinic at the University of California at San Francisco between 2006 and 2014. All participants underwent systematic evaluation with anthropometric measurements, comprehensive skin exam, transvaginal ultrasound and laboratory studies at the time of their initial visit to the clinic. Serum samples were stored and androgen studies were carried out on all stored samples at the University of Virginia. Logistic regression was employed to evaluate the association between ovarian volume or follicle number and metabolic parameters (fasting insulin, HOMA-IR, fasting glucose, 2 h glucose, waist circumference) and hyperandrogenism (free testosterone, total testosterone, DHEAS, acanthosis nigricans), controlling for age. Three-hundred thirteen patients seen during the study period met Rotterdam criteria for PCOS and had sufficient measurements for inclusion in our analysis. The odds ratio of elevated HOMA-IR for patients with a maximum ovarian volume >10 cc was 1.9 compared to those with a maximum ovarian volume of ≤10 cc (95% CI 1.0-3.4). The odds ratio of abnormal fasting insulin for patients with higher ovarian volume was 1.8 (95% CI 1.0-3.4) compared with those with lower ovarian volume. Follicle number was not significantly associated with any metabolic parameters. Increased ovarian volume is associated with markers of insulin resistance in PCOS. In concordance with prior studies, we did not find follicle number to be predictive of metabolic risk. Ovarian volume may serve as a useful tool to aid clinicians in

  16. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    Science.gov (United States)

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  17. Ultrasound-guided nerve block for inguinal hernia repair

    DEFF Research Database (Denmark)

    Bærentzen, Finn; Maschmann, Christian; Jensen, Kenneth

    2012-01-01

    Open inguinal hernia repair in adults is considered a minor surgical procedure but can be associated with significant pain. We aimed to evaluate acute postoperative pain management in male adults randomized to receive an ultrasound-guided ilioinguinal and iliohypogastric nerve block administered...

  18. Spontaneous Ovarian Pregnancy and Over Protective Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Hatice Ender Soydinç

    2016-05-01

    Full Text Available We aimed to present a case of primary ovarian pregnancy in a 31-year-old patient who presented to the emergency room with symptoms and signs of acute abdomen and positive beta HCG test. A gestation sac of 6 weeks was detected in the right ovary by transvaginal sonography. Emergency laparotomy and extirpation of the ectopic tissue was performed.

  19. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  20. Sigmoid colon volvulus immediately after ultrasound-guided simple ovarian cyst aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Firas Al-Rshoud

    2017-03-01

    Conclusion: Clinicians should bear in mind such complication(Sigmoid volvulus while draining a pelvic cyst as this procedure is adapted by some clinician as it is less invasive than surgical management of persistent simple ovarian cyst.

  1. Use of translabial three-dimensional power Doppler ultrasound for cervical assessment before labor induction.

    Science.gov (United States)

    Esin, Sertac; Yirci, Bulent; Yalvac, Serdar; Kandemir, Omer

    2017-07-26

    To compare translabial three-dimensional (3D) power Doppler ultrasound with Bishop score and transvaginal ultrasound measurements for cervical assessment before induction of labor with dinoprostone or cervical ripening balloon. Translabial cervical volume and length, vascularization indices and transvaginal cervical length were measured. Results were compared among women who had vaginal delivery at 24 h or less and more than 24 h after the insertion of the dinoprostone vaginal insert or cervical ripening balloon and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. There was no correlation between the time to delivery after a ripening agent was applied and translabial cervical volume, translabial cervical length, vascularization index (VI), flow index (FI), vascularization flow index (VFI), transvaginal cervical length and Bishop scores. The ultrasonographic measurements were no different among women who had vaginal delivery at 24 h or less and more than 24 h and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. In this study, we failed to demonstrate the superiority of translabial 3D ultrasonography over Bishop score and transvaginal ultrasonography for predicting the success of induction of labor.

  2. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  3. Transvaginal Appendectomy: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Mehmet Ali Yagci

    2014-01-01

    Full Text Available Background. Natural orifice transluminal endoscopic surgery (NOTES is a new approach that allows minimal invasive surgery through the mouth, anus, or vagina. Objective. To summarize the recent clinical appraisal, feasibility, complications, and limitations of transvaginal appendectomy for humans and outline the techniques. Data Sources. PubMed/MEDLINE, Cochrane, Google-Scholar, EBSCO, clinicaltrials.gov and congress abstracts, were searched. Study Selection. All related reports were included, irrespective of age, region, race, obesity, comorbidities or history of previous surgery. No restrictions were made in terms of language, country or journal. Main Outcome Measures. Patient selection criteria, surgical techniques, and results. Results. There were total 112 transvaginal appendectomies. All the selected patients had uncomplicated appendicitis and there were no morbidly obese patients. There was no standard surgical technique for transvaginal appendectomy. Mean operating time was 53.3 minutes (25–130 minutes. Conversion and complication rates were 3.6% and 8.2%, respectively. Mean length of hospital stay was 1.9 days. Limitations. There are a limited number of comparative studies and an absence of randomized studies. Conclusions. For now, nonmorbidly obese females with noncomplicated appendicitis can be a candidate for transvaginal appendectomy. It may decrease postoperative pain and enable the return to normal life and work off time. More comparative studies including subgroups are necessary.

  4. Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

    Science.gov (United States)

    Randelli, Filippo; Brioschi, Marco; Randelli, Pietro; Ambrogi, Federico; Sdao, Silvana; Aliprandi, Alberto

    2018-01-01

    Fluid samples obtained from an affected joint still play a central role in the diagnosis of periprosthetic joint infection (PJI). It is the only preoperative test able to discover the causative microbiological agent. In the hip, fluid aspiration can be performed through fluoroscopy, ultrasound, or, less commonly, computed tomography. However, there is still a lack of consensus on which method is preferable in terms of efficacy and costbenefit. We, therefore, asked whether (1) the benefits in terms of sensitivity and specificity and (2) the costs were comparable between fluoroscopy- and ultrasound-guided joint aspirations in a suspicious of hip PJI. Between 2013 and 2016, 52 hip aspirations were performed on 49 patients with clinical, radiological, or serological suspicion of PJI, waiting for a revision surgery. The patients were divided in two groups: fluoroscopy- (n = 26) vs ultrasound-guided hip aspiration group (n = 26). These groups were also divided in control and infected patients. The criteria of MusculoSkeletal Infection Society (MSIS) were used, as gold standard, to define PJI. (1) Ultrasound-guided aspiration revealed valid sensitivity (89% vs 60%) and specificity (94% vs 81%) in comparison with fluoroscopic-guided aspiration. (2) The cost analysis was also in favor of ultrasound-guided aspiration (125.30€) than fluoroscopic-guided aspiration (343.58€). We concluded that ultrasound-guided hip aspiration could represent a valid, safe, and less expensive diagnostic alternative to fluoroscopic-guided aspiration in hip PJI.

  5. A prospective study of transobturator tape as treatment for stress urinary incontinence after transvaginal mesh repair.

    Science.gov (United States)

    Lau, Hui-Hsuan; Su, Tsung-Hsien; Huang, Wen-Chu; Hsieh, Ching-Hung; Su, Chin-Hui; Chang, Rhu-Chu

    2013-10-01

    The transobturator suburethral sling is a common surgical treatment for stress urinary incontinence (SUI). In patients with incontinence after trocar-guided transvaginal mesh repair (Prolift), data on outcome remain limited. In the present study, we hypothesized that transobturator tape in such cases is assumed to be as effective as surgery alone. This was a prospective analysis of outcomes of transobturator slings in women who had undergone transvaginal mesh repair and in those who underwent sling surgery alone (controls). Objective cure was defined as the absence of urinary leakage during the stress test at filling cystometry and a negative cough test during pelvic examination. The success rates were evaluated 3-6 months postoperatively. One hundred women were recruited for the study. Compared to the control group, women after transvaginal mesh repair had a significantly lower objective success rate (62 vs 86%, p = 0.005) and poorer bladder neck mobility (0.5 ± 0.8 vs 1.1 ± 0.5 cm, p = 0.001). The transobturator sling has lower objective success rate in women after transvaginal mesh that may be due to decreased bladder neck mobility. Patients with post-mesh repair SUI who opt for sling surgery should be informed of these less satisfactory outcomes during preoperative counseling.

  6. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  7. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    Science.gov (United States)

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Outcome of ultrasound-guided small-bore catheter drainage in exudative pleural effusions.

    Science.gov (United States)

    Kiranantawat, Nantaka; Sungsiri, Jitpreedee; Geater, Sarayut L

    2014-05-01

    To evaluate the outcome and safety of ultrasound-guided percutaneous catheter drainage of exudative pleural effusion. The present study was a retrospective analysis of 412 pleural effusions from 373 patients that underwent ultrasound-guided small-bore catheter drainage in exudative pleural effusions between 2004 and 2009. The two most common causes for drainage were parapneumonic effusion or empyema (52.2%) and malignant effusion (30.3%), while the remains were trauma, iatrogenic, and others. Overall clinical success rate was 76.5%. The success rate was lower among malignant pleural effusion (p = 0.003). Causes of effusion were the only independent predictors related to success. Only five (1.2%) patients developed complication during the procedure. Seventy-five of 412 effusions (15.8%) developed complication during the period of drainage; the majority were drain blockage (9%) and accidental dislodgment (4.1%). Ultrasound-guided small-bore catheter drainage was a safe and efficient procedure for exudative pleural effusions.

  9. Ultrasound-guided hydrostatic reduction of intestinal intussusception: description of three cases

    Directory of Open Access Journals (Sweden)

    Martha Hanemann Kim

    2008-09-01

    Full Text Available With the objective of reporting the technique of ultrasound-guided hydrostatic reduction of intestinal intussusception, three cases with confirmed diagnosis of the disease submitted to reduction with this technique are described. All cases had successful reductions with no complications. One patient experienced a recurrence of the invagination eight days after treatment, which was surgically corrected. The technique of hydrostatic reversal of intestinal intussusception guided by ultrasound may be used in place of the conventional barium enema, since it is a minimally invasive and safe method, with high rates of success and few complications.

  10. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    Science.gov (United States)

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  11. Magnetic Resonance-Guided High-Intensity-Focused Ultrasound for Palliation of Painful Skeletal Metastases: A Pilot Study.

    Science.gov (United States)

    Chan, Michael; Dennis, Kristopher; Huang, Yuexi; Mougenot, Charles; Chow, Edward; DeAngelis, Carlo; Coccagna, Jennifer; Sahgal, Arjun; Hynynen, Kullervo; Czarnota, Gregory; Chu, William

    2017-10-01

    Bone is one of the most common sites of metastases, with bone metastases-related pain representing a significant source of morbidity among patients with cancer. Magnetic resonance-guided focused ultrasound is a noninvasive, outpatient modality with the potential for treating painful bone metastases. The aim of this study is to report our initial experience with magnetic resonance-guided focused ultrasound in the treatment of bone metastases and our preliminary analysis of urinary cytokine levels after therapy. This was a single-center pilot study of 10 patients with metastatic cancer to investigate the feasibility of magnetic resonance-guided focused ultrasound for primary pain control in device-accessible skeletal metastases. Treatments were performed on a clinical magnetic resonance-guided focused ultrasound system using a volumetric ablation technique. Primary efficacy was assessed using Brief Pain Inventory scores and morphine equivalent daily dose intake at 3 time points: before, day 14, and day 30 after the magnetic resonance-guided focused ultrasound treatment. Urine cytokines were measured 3 days before treatment and 2 days after the treatment. Of the 10 patients, 8 were followed up 14 days and 6 were followed up 30 days after the treatment. At day 14, 3 patients (37.5%) exhibited partial pain response and 4 patients (50%) exhibited an indeterminate response, and at day 30 after the treatment, 5 patients (83%) exhibited partial pain response. No treatment-related adverse events were recorded. Of the urine cytokines measured, only Transforming growth factor alpha (TGFα) demonstrated an overall decrease, with a trend toward statistical significance ( P = .078). Our study corroborates magnetic resonance-guided focused ultrasound as a feasible and safe modality as a primary, palliative treatment for painful bone metastases and contributes to the limited body of literature using magnetic resonance-guided focused ultrasound for this clinical indication.

  12. Transvaginal mesh procedures for pelvic organ prolapse.

    Science.gov (United States)

    Walter, Jens-Erik

    2011-02-01

    To provide an update on transvaginal mesh procedures, newly available minimally invasive surgical techniques for pelvic floor repair. The discussion is limited to minimally invasive transvaginal mesh procedures. PubMed and Medline were searched for articles published in English, using the key words "pelvic organ prolapse," transvaginal mesh," and "minimally invasive surgery." Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Searches were updated on a regular basis, and articles were incorporated in the guideline to May 2010. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on the Preventive Health Care. Recommendations for practice were ranked according to the method described in that report (Table 1). Counselling for the surgical treatment of pelvic organ prolapse should consider all benefits, harms, and costs of the surgical procedure, with particular emphasis on the use of mesh. 1. Patients should be counselled that transvaginal mesh procedures are considered novel techniques for pelvic floor repair that demonstrate high rates of anatomical cure in uncontrolled short-term case series. (II-2B) 2. Patients should be informed of the range of success rates until stronger evidence of superiority is published. (II-2B) 3. Training specific to transvaginal mesh procedures should be undertaken before procedures are performed. (III-C) 4. Patients should undergo thorough preoperative counselling regarding (a) the potential serious adverse sequelae of transvaginal mesh repairs, including mesh exposure, pain, and dyspareunia; and (b) the limited data available

  13. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  14. Ultrasound-guided endoscopic transgastric drainage of a post ...

    African Journals Online (AJOL)

    Despite of a number of techniques in the armentarium of the paediatric surgeon, the management of pancreatic pseudocysts remains a challenge. We report on a case of a 5-year-old child with a post-traumatic pancreatic pseudocyst who was successfully treated with endoscopic ultrasound-guided transgastric approach.

  15. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  16. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  17. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  18. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  19. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    Science.gov (United States)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  20. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    International Nuclear Information System (INIS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-01-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg–Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited. (paper)

  1. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    Science.gov (United States)

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  2. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    Science.gov (United States)

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  3. MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

    International Nuclear Information System (INIS)

    Hesley, Gina K.; Gorny, Krzysztof R.; Woodrum, David A.

    2013-01-01

    Magnetic resonance imaging–guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

  4. Ultrasound-Guided Versus Landmark-Guided Local Corticosteroid Injection for Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Babaei-Ghazani, Arash; Roomizadeh, Peyman; Forogh, Bijan; Moeini-Taba, Seyed-Mohammad; Abedini, Amin; Kadkhodaie, Mona; Jahanjoo, Fateme; Eftekharsadat, Bina

    2018-04-01

    To review the literature and assess the comparative effectiveness of ultrasound-guided versus landmark-guided local corticosteroid injections in patients with carpal tunnel syndrome (CTS). Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Embase (Ovid), and Web of Science (from inception to February 1, 2017). Randomized controlled trials (RCTs) comparing ultrasound-guided injection with landmark-guided injection in patients with CTS were included. Two authors independently screened abstracts and full texts. The outcomes of interest were Symptom Severity Scale (SSS) and Functional Status Scale (FSS) scores of the Boston Carpal Tunnel Questionnaire and 4 electrodiagnostic parameters, including compound muscle action potential (CMAP), sensory nerve action potential (SNAP), distal motor latency (DML), and distal sensory latency (DSL). Overall, 569 abstracts were retrieved and checked for eligibility; finally, 3 RCTs were included (181 injected hands). Pooled analysis showed that ultrasound-guided injection was more effective in SSS improvement (mean difference [MD], -.46; 95% confidence interval [CI], -.59 to -.32; P.99), DML (MD, .05; 95% CI, -.30 to .39; P=.80), or DSL (MD, .00; 95% CI, -.65 to .65; P>.99). This review suggested that ultrasound-guided injection was more effective than landmark-guided injection in symptom severity improvement in patients with CTS; however, no significant differences were observed in functional status or electrodiagnostic improvements between the 2 methods. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    DEFF Research Database (Denmark)

    Wyse, Jonathan M; Battat, Robert; Sun, Siyu

    2017-01-01

    OBJECTIVES: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). METHODS: Six important clinical...

  6. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    NARCIS (Netherlands)

    Wyse, J.M. (Jonathan M.); Battat, R. (Robert); Sun, S. (Siyu); A. Saftoiu (Adrian); Siddiqui, A.A. (Ali A.); Leong, A.T. (Ang Tiing); Arias, B.L.A. (Brenda Lucia Arturo); Fabbri, C. (Carlo); Adler, D.G. (Douglas G.); Santo, E. (Erwin); Kalaitzakis, E. (Evangelos); Artifon, E. (Everson); Mishra, G. (Girish); Okasha, H.H. (Hussein Hassan); J.-W. Poley (Jan-Werner); Guo, J. (Jintao); Vila, J.J. (Juan J.); Lee, L.S. (Linda S.); Sharma, M. (Malay); Bhutani, M.S. (Manoop S.); M. Giovannini (Marcello); Kitano, M. (Masayuki); Eloubeidi, M.A. (Mohamad Ali); Khashab, M.A. (Mouen A.); Nguyen, N.Q. (Nam Q.); Saxena, P. (Payal); Vilmann, P. (Peter); Fusaroli, P. (Pietro); Garg, P.K. (Pramod Kumar); Ho, S. (Sammy); Mukai, S. (Shuntaro); Carrara, S. (Silvia); Sridhar, S. (Subbaramiah); S. Lakhtakia (S.); Rana, S.S. (Surinder S.); Dhir, V. (Vinay); Sahai, A.V. (Anand V.)

    2017-01-01

    textabstractObjectives: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). Methods: Six important

  7. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  8. Diagnosing and management of iatrogenic moderate and severe ovarian hyperstymulation syndrome (OHSS in clinical material.

    Directory of Open Access Journals (Sweden)

    Anna Fritz

    2008-04-01

    Full Text Available Severe ovarian hyperstymulation syndrome is a rare but potentially life-threatening complication in patients undergoing assisted reproductive techniques (ART. The pathogenesis of this condition is likely to be multifactorial. The aim of the retrospective study was to present management in moderate and severe iatrogenic ovarian hyperstymulation syndrome (OHSS in clinical material. The study group was 19 women, admitted to the Department of Obstetrics and Gynecology in Central Clinical Hospital of Ministry of Interior and Administration in Warsaw from large outpatient infertility center "Novum" in Warsaw with moderate and severe OHSS between 14.07.2004 and 8.11.2005. Laboratory tests and ultrasound examination of the ovarian size and ascites were performed, abdominal circumference was measured. Patients were treated with rehydration with intravenous crystalloids and colloids, diuretics, antibiotics, anticoagulants and ultrasound-guided paracentesis if symptoms of ascites become severe (ascites causes pain and compromised pulmonary function. Oral intake of water was restricted, monitoring of fluid intake and output, and daily monitoring of body weight was performed. During treatment controlled laboratory tests were done. In one patient occurred intra-abdominal hemorrhage from ovarian rupture and laparotomy with oophorectomy was performed. The ovarian hyperstimulation syndrome is still a difficult diagnostic and therapeutic problem and more studies are required to elucidate pathophysiology of OHSS. Because of still unknown etiology treatment is empirical and in most of cases bases on experience of medical team. Thus, the management in individual patients varies according to the severity of ovarian hyperstymulation syndrome and its complications.

  9. MRI findings of uterine tumor resembling ovarian sex-cord tumor: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Hwan; Kim, Hee Jin; Han, Hyun Young; Hwang, In Taek; Kim, Ju Heon; Lee, Seung Yeon [Eulji University Hospital, Eulji University School of Medicine, Daejeon (Korea, Republic of)

    2017-04-15

    Uterine tumor resembling ovarian sex-cord tumor is a very rare uterine neoplasm that was first described by Clement and Scully in 1976. Since then, approximately 70 cases have been reported. However, these case reports have mainly described and discussed the pathologic and clinical features, and few radiologic findings have been presented. We experienced a case of a uterine tumor resembling ovarian sex-cord tumor, which was considered a uterine leiomyoma or leiomyosarcoma upon initial impression at preoperative evaluation including transvaginal ultrasonography and pelvic magnetic resonance imaging. Its diagnosis was pathologically confirmed after total abdominal hysterectomy.

  10. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    Science.gov (United States)

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7  6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p  4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.

  11. The accuracy of transvaginal sonography to detect endometriosis cyst

    Science.gov (United States)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  12. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  14. Percutaneous antegrade pyelgraphy guided by ultrasound

    International Nuclear Information System (INIS)

    Kim, Jin Gyoo; Chung, Chun Phil; Lee, Suk Hong; Sol, Chang Hyo; Kim, Byung Soo

    1985-01-01

    The authors performed percutaneous antegrade pyelography guided by ultrasound on 33 patients, from June 1982 to October 1984, at the Department of Radiology, Busan National University Hospital. The results obtained were as follows: 1. Of the 31 cases, 17 cases (51.5%) were female and 16 cases (48.5%) were male, and age distribution was nearly even, but most prevalent age group was third decade. 2. Comparing intravenous pyelographic findings with ultrasonographic findings, pyelographically nonvisualized kidney 15 cases (45.5%) were hydronephrosis 12 cases, multiple cysts 2 cases, and intrarenal cystic mass 1 case, ultrasonographically. Pyelographically hydronephrosis 9 cases (27.3%) were all hydronephrosis, ultrasonographically. Intrarenal mass 5 cases (15.2%) were all intrarenal cystic mass, NVK with air kidney 1 case (3.0%) was air in perirenal space, partial NVK 1 case (3.0%) was perirenal fluid, suprarenal mass 1 case (3.0%) was suprarenal intrarenal and huge perirenal cystic masses, ultrasonographically. 3. On technical reliability of antegrade pyelography under ultrasound guide, 31 cases (93.9%) could be done fluid aspiration and visualization, and 2 cases (6.1%) could be only done fluid aspiration but failed visualization. 31 successful cases were visualization of collecting systems 23 cases, visualization of cyst 6 case, and visualization of perirenal space 2 cases. 2 partical successful cases were perirenal injection 1 case and parenchymal injection 1 case. 4. On fluid aspiration, 22 cases (66.7%) were clear, but 11 cases (33.3%) were not clear, which were pus 7 cases, turbid urine 2 cases, bloody urine 1 case, and bloody pus and air 1 case. 5. Comparing ultrasonographic findings with antegrade pyelographic findings, ultrasonographiclly hydronephrosis 21 cases revealed obstruction in 16 cases, antegrade pyelographicaaly, which were consisted of ureteral stricture 14 case, ureteral stone 1 case, and ureteral mass 1 case, non-obstruction in 4 cases, which

  15. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    Science.gov (United States)

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  16. Ultrasound-guided procedures around the wrist and hand: How to do

    International Nuclear Information System (INIS)

    Orlandi, Davide; Corazza, Angelo; Silvestri, Enzo; Serafini, Giovanni; Savarino, Edoardo Vincenzo; Garlaschi, Giacomo; Mauri, Giovanni; Cimmino, Marco Amedeo; Sconfienza, Luca Maria

    2014-01-01

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand

  17. Ultrasound-guided procedures around the wrist and hand: How to do

    Energy Technology Data Exchange (ETDEWEB)

    Orlandi, Davide; Corazza, Angelo [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Silvestri, Enzo [Diagnostica per Immagini, Ospedale Evangelico Internazionale, Corso Solferino 29A, 16100 Genova (Italy); Serafini, Giovanni [Dipartimento di Diagnostica per Immagini, Ospedale Santa Corona, Via XXV Aprile 38, 17037 Pietra Ligure, Savona (Italy); Savarino, Edoardo Vincenzo [Dipartimento di Scienze Chirurgiche, Oncologiche e Gastroenterologiche, Università degli Studi di Padova, Via Giustiniani, Padova (Italy); Garlaschi, Giacomo [Dipartimento di Scienze per la Salute, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Mauri, Giovanni [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Cimmino, Marco Amedeo [Dipartimento di Medicina Interna, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Sconfienza, Luca Maria, E-mail: io@lucasconfienza.it [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Piazza Malan 2, San Donato Milanese, Milano (Italy)

    2014-07-15

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand.

  18. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

  19. Ultrasound-guided continuous phrenic nerve block for persistent hiccups.

    NARCIS (Netherlands)

    Renes, S.H.; Geffen, G.J. van; Rettig, H.C.; Gielen, M.J.M.; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Phrenic nerve block can be performed and repeated if necessary for persistent hiccups, when conservative and pharmacological treatment is unsuccessful. We report the first description of an in-plane ultrasound (US)-guided phrenic nerve block (PhNB) with a catheter, after US investigation

  20. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  1. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  2. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  3. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  5. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  6. Ovarian surgery for symptom relief in women with polycystic ovary syndrome.

    Science.gov (United States)

    Lepine, Sam; Jo, Junyoung; Metwally, Mostafa; Cheong, Ying C

    2017-11-10

    ).The quality of the evidence ranged from very low to moderate quality. The main limitations were imprecision associated with the low number of studies, inconsistency and risk of bias associated with the inability to blind participants. There were too few studies to assess risk of publication bias. Menstrual RegularityTwo studies compared LOD versus metformin (n=226) but no conclusions could be drawn with regard to menstrual regularity, as their findings were inconsistent and they were unsuitable for pooling. There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when LOD was compared with medical treatment including metformin + clomiphene (OR 1.02, 95% CI 0.64 to 1.64, 2 studies, 332 women, I 2 = 13%, low-quality evidence), letrozole (OR 1.08, 95% CI 0.64 to 1.84, 1 study, 260 women, low-quality evidence), or metformin + letrozole (OR 0.95, 95% CI 0.49 to 1.81, 1 study, 146 women, low-quality evidence). However, one study reported that LOD was superior to gonadotrophin (OR 19.2, 95% CI 3.17 to 116.45, 1 study, 35 women, very low-quality evidence).There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when bilateral unipolar LOD was compared to unilateral LOD (OR 1.51, 95% CI 0.62 to 3.71, 2 studies, 104 women, I 2 = 0%, moderate-quality evidence), transvaginal ultrasound-guided LOD (OR 1.23, 95% CI 0.64 to 2.37, 1 study, 147 women, low-quality evidence), LOD using adjusted thermal dose in accordance with the ovarian volume (OR 0.42, 95% CI 0.16 to 1.14, 1 study, 115 women, low-quality evidence) or bipolar LOD (OR 1.00, 95% CI 0.05 to 18.57, 1 study, 18 women, low-quality evidence).Four to five punctures per ovary may improve the rate of women reporting menstrual regularity compared with two or fewer (OR 16.04, 95% CI 4.19 to 61.34, 2 studies, 73 women, I 2 = 0%, low-quality evidence). Androgenic SymptomsThere was probably little or no difference in improvement in

  7. Ultrasound Imaging of the Pelvic Floor: linking anatomical findings with clinical symtoms

    NARCIS (Netherlands)

    A.B. Steensma (Anneke)

    2009-01-01

    textabstractFor evaluation of pelvic floor and lower urinary tract dysfunction the use of transabdominal ultrasound was first documented in the early eighties, with the translabial [1], transrectal [2] and transvaginal [3, 4] techniques developing somewhat later. To obtain a translabial

  8. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  9. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    Science.gov (United States)

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  10. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2006-08-15

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder.

  11. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung

    2006-01-01

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder

  12. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  13. Ovarian tubercular abscess mimicking ovarian carcinoma: A rare case report

    Directory of Open Access Journals (Sweden)

    Abinash Agarwala

    2015-01-01

    Full Text Available Although genito-urinary tuberculosis is common, reports of isolated ovarian tubercular abscess are rare. Ovarian tubercular abscess may mimics that of an ovarian tumor, leading to diagnostic difficulties. We reported a case report of 35 years woman presented with chronic pain abdomen, weight loss, low-grade fever and a right ovarian mass on ultrasound, with a significantly elevated CA-125 level. On clinical and radiological evidence, diagnosis of ovarian carcinoma was made, and laparotomy was performed with resection of the ovary. Postoperative specimen sent for histological examination that revealed classic epithelioid granuloma and acid-fast bacilli were present in Ziehl-Neelsen stain. Patient was put on antitubercular regimen from our Dots center. She is improving clinical after taking antitubercular drug and is on regular follow up at our chest outpatient department. Ovarian tubercular abscess is common in young women living in endemic zones, but case report of isolated tubercular abscess is rarely reported. CA-125 can be raised in both ovarian tubercular abscess and ovarian carcinoma, and only imaging is not always conclusive. Laparotomy followed by tissue diagnosis can be helpful in this situation. As the prognosis and treatment outcome of ovarian tubercular abscess and ovarian carcinoma is different, proper diagnosis by laparotomy should be done. Early diagnosis of ovarian tubercular abscess is vital as untreated disease can lead to infertility.

  14. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    International Nuclear Information System (INIS)

    Algin, Oktay; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-01-01

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

  15. Efficacy of Ablation Therapy for Secondary Hyperparathyroidism by Ultrasound Guided Percutaneous Thermoablation.

    Science.gov (United States)

    Zhao, Junfeng; Qian, Linxue; Zu, Yuan; Wei, Ying; Hu, Xiangdong

    2016-05-01

    The objective of this study was to explore the value of ultrasound-guided percutaneous microwave thermoablation to treat secondary hyperparathyroidism (SHPT). One hundred and thirty-eight parathyroid glands from 56 patients with SHPT were ablated in this study. All the parathyroid glands were evaluated by real-time contrast-enhanced ultrasound before, during and after ablation. Changes in serum parathyroid hormone (sPTH) levels were measured before treatment and at 1 h, 1 wk, 1 mo and 6 mo after thermoablation treatment. All 56 cases had a 1-mo follow-up, and 34 cases had a 6-mo follow-up. The sPTH level of the 54 cases 1 mo after ablation was significantly lower than that before (p 0.05). Ultrasound-guided percutaneous microwave thermoablation is a feasible and effective non-surgical alternative treatment for SHPT patients. Copyright © 2016. Published by Elsevier Inc.

  16. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  17. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  18. Does the addition of saline infusion sonohysterography to transvaginal ultrasonography prevent unnecessary hysteroscopy in premenopausal women with abnormal uterine bleeding?

    Science.gov (United States)

    Short, John; Sharp, Benjamin; Elliot, Nikki; McEwing, Rachael; McGeoch, Graham; Shand, Brett; Holland, Kieran

    2016-08-01

    This observational case series in 65 premenopausal women with abnormal uterine bleeding evaluated whether transvaginal ultrasound followed by saline infusion sonohysterography (SIS) prevented unnecessary hysteroscopy. Although SIS indicated that hysteroscopy was unnecessary in eight women, this benefit was offset by the invasive nature of the scan, the number of endometrial abnormalities falsely detected by SIS and the cost of the additional investigation. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  19. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    Science.gov (United States)

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  20. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    Science.gov (United States)

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  1. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  2. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  3. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  4. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    Directory of Open Access Journals (Sweden)

    Vetrivel Chezian Sengodan

    2017-01-01

    Full Text Available Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001 at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  5. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  6. Intra- and inter-observer reproducibility and generalizability of first trimester uterine artery pulsatility index by transabdominal and transvaginal ultrasound

    NARCIS (Netherlands)

    Marchi, Laura; Zwertbroek, Eva; Snelder, Judith; Kloosterman, Maaike; Bilardo, Caterina Maddalena

    2016-01-01

    Objectives The primary aim of the study was to assess intra-observer and inter-observer reproducibility and generalizability (general reliability) of first trimester Doppler measurements of uterine arteries (UtA) performed both transabdominally (TA) and transvaginally (TV). Secondary aims were to

  7. Evolução do comprimento cervical uterino na gestação, avaliado pela ultra-sonografia transvaginal Changes in cervical length during pregnancy measured by transvaginal ultrasound

    Directory of Open Access Journals (Sweden)

    Reginaldo Antônio de Oliveira Freitas-Júnior

    2003-03-01

    Full Text Available OBJETIVO: analisar a evolução do comprimento cervical uterino, ao longo da gestação, avaliado por meio da ultra-sonografia transvaginal. MÉTODOS: foi realizado estudo prospectivo, longitudinal, no qual 82 gestantes hígidas foram acompanhadas desde o início da gestação, das quais 49 mantiveram o seguimento até o parto sem complicações da gravidez, sendo examinadas a cada quatro semanas, e agrupadas, conforme a paridade, em nulíparas ou com um ou mais partos anteriores. O comprimento do colo uterino foi avaliado em vista sagital pela ultra-sonografia transvaginal, com a medida linear da distância entre os orifícios cervicais interno e externo. RESULTADOS: as médias de comprimento do colo uterino, bem como os percentis 5, 25, 50, 75 e 95, em função da idade gestacional, não diferiram significativamente entre os grupos estudados (p>0.05. No intervalo entre a 20ª e a 24ª semana gestacional o comprimento cervical variou entre 28, 35 e 47,2 mm, com os percentis 5, 50 e 95, respectivamente. O comprimento cervical uterino diminuiu progressivamente ao longo da gestação normal, sendo esse encurtamento significativo após a 20ª semana de gravidez e mais expressivo após a 28ª semana (pPURPOSE: to establish a normality curve of cervical length during pregnancy measured by transvaginal ultrasonography. METHODS: we conducted a prospective, longitudinal study on 82 healthy pregnant women who were followed up from the beginning of pregnancy to delivery at four-week intervals, of whom 49 concluded the study. Patients were divided according to parity into nulliparous women and women with one or more previous deliveries. Cervical length was measured in a sagittal view by transvaginal ultrasonography, as the linear distance between internal and external cervical os. RESULTS: no significant difference was observed in mean cervical length or the 5th, 25, 50th, 75th, or 95th percentile according to gestational age between groups (p>0

  8. Physician Knowledge and Awareness of CA-125 As a Screen for Ovarian Cancer in the Asymptomatic, Average-Risk Population

    Science.gov (United States)

    Stewart, Sherri L.; Rim, Sun Hee; Gelb, Cynthia A.

    2012-01-01

    Effective early detection strategies for ovarian cancer do not exist. Current screening guidelines recommend against routine screening using CA-125 alone or in combination with transvaginal ultrasonography (TVS). In this study, the authors used the 2008 "DocStyles" survey to measure clinician beliefs about the effectiveness of CA-125 and…

  9. Ultrasound-guided truncal blocks: A new frontier in regional anaesthesia

    Directory of Open Access Journals (Sweden)

    Arunangshu Chakraborty

    2016-01-01

    Full Text Available The practice of regional anaesthesia is rapidly changing with the introduction of ultrasound into the working domain of the anaesthesiologist. New techniques are being pioneered. Among the recent techniques, notable are the truncal blocks, for example, the transversus abdominis plane block, rectus sheath block, hernia block and quadratus lumborum block in the abdomen and the pectoral nerves (Pecs block 1 and 2, serratus anterior plane block and intercostal nerve block. This narrative review covers the brief anatomical discourse along with technical description of the ultrasound-guided truncal blocks.

  10. Pituitary and ovarian abnormalities demonstrated by CT and ultrasound in children with features of the McCune-Albright syndrome

    International Nuclear Information System (INIS)

    Rieth, K.G.; Comite, F.; Shawker, T.H.; Cutler, G.B. Jr.

    1984-01-01

    In a random series of 97 children referred to the National Institutes of Health with a presumptive diagnosis of precocious puberty, eight girls were found to have features of the McCune-Albright syndrome, including fibrous dysplasia of bone and/or skin lesions resembling cafe au lait spots. Radiographic evaluation of these patients included computed tomography of the head and pelvic ultrasound. The pituitary glands were suspicious for abnormality in five of the eight girls. Seven girls underwent pelvic ultrasound, and in all of them the ovaries were considered to be abnormal for their chronological age; in addition, two had functional ovarian cysts. The role of diagnostic radiological studies in the diagnosis of this syndrome is discussed

  11. Prevalence of ovarian adrenal rest tumours and polycystic ovaries in females with congenital adrenal hyperplasia: results of ultrasonography and MR imaging.

    NARCIS (Netherlands)

    Stikkelbroeck, N.M.; Hermus, A.R.M.M.; Schouten, D.; Suliman, H.M.; Jager, G.J.; Braat, D.D.M.; Otten, B.J.

    2004-01-01

    The aim of the investigation was to assess the prevalence of ovarian adrenal rest tumours and polycystic ovaries in female patients with congenital adrenal hyperplasia (CAH). Thirteen female CAH patients (median age 19.8 years, range 14.8-23.5 years) underwent transvaginal (n=6) or transabdominal

  12. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  13. Ultrasound-Guided Bipolar Umbilical Cord Occlusion in Complicated Monochorionic Pregnancies

    DEFF Research Database (Denmark)

    Schou, Katrine V; Jensen, Lisa N; Jørgensen, Connie

    2017-01-01

    INTRODUCTION: Ultrasound-guided bipolar umbilical cord occlusion (UCO) is used in complicated monochorionic multiple pregnancies in Denmark. The aim of this study was to assess a learning curve in the procedure of UCO. MATERIALS AND METHODS: One hundred and two monochorionic pregnancies treated...

  14. A novel ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  15. Ultrasound-guided injection for plantar fasciitis: A brief review

    Directory of Open Access Journals (Sweden)

    A S Nair

    2016-01-01

    Full Text Available Plantar fasciitis (PF is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation.

  16. Ultrasound/Magnetic Resonance Image Fusion Guided Lumbosacral Plexus Block – A Clinical Study

    DEFF Research Database (Denmark)

    Strid, JM; Pedersen, Erik Morre; Søballe, Kjeld

    2014-01-01

    in a double-blinded randomized controlled trial with crossover design. MR datasets will be acquired and uploaded in an advanced US system (Epiq7, Phillips, Amsterdam, Netherlands). All volunteers will receive SSPS blocks with lidocaine added gadolinium contrast guided by US/MR image fusion and by US one week......Background and aims Ultrasound (US) guided lumbosacral plexus block (Supra Sacral Parallel Shift [SSPS]) offers an alternative to general anaesthesia and perioperative analgesia for hip surgery.1 The complex anatomy of the lumbosacral region hampers the accuracy of the block, but it may be improved...... by guidance of US and magnetic resonance (MR) image fusion and real-time 3D electronic needle tip tracking.2 We aim to estimate the effect and the distribution of lidocaine after SSPS guided by US/MR image fusion compared to SSPS guided by ultrasound. Methods Twenty-four healthy volunteers will be included...

  17. Ultrasound guided aspiration cytology of neck mass except thyroid mass

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Suh, Jung Ho; Park, Cheong Soo; Lee, Gwang Gil

    1988-01-01

    Results of ultrasound guided aspiration cytology of extrathyroidal neck masses of 73 patients were reviewed. Included cases were 23 malignant lesions; 16 metastatic tumors, 4 lymphomas, 3 salivary gland tumors and 50 benign lesions: 24 tuberculous lymphadenites, 15 abscess, 3 benign lymph node hyperplasias, etc. There were one case of false negative and none of false positive result for malignancy. In two cases of malignancy, insufficient cellular material was obtained. In one case of lymphoma, and a benign lymph node hyperplasia, it was difficult to distinguish between benignancy and malignancy on cytologic smear. For the malignant lesions, sensitivity was 83%, specificity was 98%, and overall accuracy was 93%. There were none who had suffered adverse effect from the procedure. Ultrasound guided aspiration cytology seems to be simple, accurate and safe diagnostic modality for neck masses especially in condition that malignancy can not be excluded

  18. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    O'Donnell, Brian D

    2009-07-01

    Ultrasound guidance facilitates precise needle and injectate placement, increasing axillary block success rates, reducing onset times, and permitting local anesthetic dose reduction. The minimum effective volume of local anesthetic in ultrasound-guided axillary brachial plexus block is unknown. The authors performed a study to estimate the minimum effective anesthetic volume of 2% lidocaine with 1:200,000 epinephrine (2% LidoEpi) in ultrasound-guided axillary brachial plexus block.

  19. Image-guided focused ultrasound ablation of breast cancer: current status, challenges, and future directions

    NARCIS (Netherlands)

    Schmitz, A.C.; Gianfelice, D.; Daniel, B.L.; Mali, W.P.T.M.; Bosch, M.A.A.J. van den

    2008-01-01

    Image-guided focussed ultrasound (FUS) ablation is a noninvasive procedure that has been used for treatment of benign or malignant breast tumours. Image-guidance during ablation is achieved either by using real-time ultrasound (US) or magnetic resonance imaging (MRI). The past decade phase I

  20. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  1. Diagnosis and management of simple ovarian cysts: an audit

    International Nuclear Information System (INIS)

    Simcock, B.

    2005-01-01

    Simple ovarian cysts are common. The aim of clinical management is to optimize the treatment of malignant and premalignant cysts while minimizing intervention for cysts likely to resolve spontaneously. In this retrospective study, ovarian cysts over 30 mm in diameter were detected in 90 women. Of this population, 75 were premenopausal, 13 postmenopausal, and two had undergone a hysterectomy. Thirteen women presented acutely. Family history of breast, ovary or colon cancer was not ascertained in any of the women. None had CA125 levels performed. In 22 cases, the cyst was aspirated; only 10 of these had follow-up ultrasound. Laparotomy was performed in 25 premenopausal women, the two perimenopausal women and eight postmenopausal women. Average cyst size was 71 mm (range 40-80 mm) in the laparoscopy group, and 72 mm (range 36-180 mm) in the laparotomy group. After initial diagnosis at ultrasound, a follow-up scan was performed 4-16 weeks later. The final diagnosis was ovarian neoplasm in 13 and hydrosalpinx in two. None had a malignancy. Documentation at ultrasound was often inadequate, and management of the women with an ovarian cyst was haphazard. Guidelines on management of simple ovarian cysts are likely to improve clinical practice. Copyright (2005) Blackwell Science Pty Ltd

  2. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  3. Preoperative Diagnosis of Fallopian Tube Malignancy with Transvaginal Color Doppler Ultrasonography and Magnetic Resonance Imaging after Negative Hysteroscopy for Postmenopausal Bleedin

    OpenAIRE

    Arko, Darja; Žegura, Branka; Virag, Mirjana; Fokter Dovnik, Nina; Takač, Iztok

    2014-01-01

    Primary Fallopian tube carcinoma is a rare malignancy and is not often diagnosed preoperatively. We present a case of a 67-year old woman who complained of postmenopausal vaginal bleeding. After a negative hysteroscopy, transvaginal ultrasound showed a well vascularized solid-cystic tumor in the adnexal region separate from the ovary. The presence of an adnexal mass was confirmed by MR imaging. Total abdominal hysterectomy with bilateral salpingoophorectomy, omentectomy and appendectomy, as w...

  4. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  5. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    International Nuclear Information System (INIS)

    Arvanitis, Costas D; McDannold, Nathan; Livingstone, Margaret S

    2013-01-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood–brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood–brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that

  6. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  7. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    Science.gov (United States)

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Ovarian synchronisation in wood bison (Bison bison athabascae) during the anovulatory season.

    Science.gov (United States)

    Palomino, J Manuel; McCorkell, Robert B; Woodbury, Murray R; Adams, Gregg P

    2014-01-01

    Two experiments were performed in wood bison during the anovulatory season to establish an effective protocol for ovarian synchronisation. In an untreated control phase, bison cows (n=19) were examined daily to establish the interval to new follicular wave emergence (4.9±0.7 days) for the purposes of comparison with the experimental treatments. In Experiment 1, bison were treated by transvaginal ultrasound-guided follicular ablation (n=9) or with 2mg, i.m., 17β-oestradiol (n=10). In Experiment 2, bison were treated by follicular ablation (n=9) or with 2mg, i.m., 17β-oestradiol +100mg, i.m., progesterone (n=10). In Experiment 1, the interval to new wave emergence for control, follicular ablation and 17β-oestradiol-treated groups was 4.9±0.7, 1.1±0.1 and 3.1±0.4 days, respectively (P<0.05). The degree of synchrony was 2.4±0.4, 0.2±0.1 and 0.8±0.2 days, respectively (P<0.05). In Experiment 2, the interval to new wave emergence for control, follicular ablation and 17β-oestradiol + progesterone-treated groups was 4.9±0.7, 1.2±0.2 and 3.3±0.3 days, respectively (P<0.05), and the degree of synchrony was 2.4±0.4, 0.2±0.1, and 0.8±0.2 days, respectively (P<0.05). The degree of synchrony did not differ between ablation and hormone treatment groups in either experiment, but was greater in treatment groups than in the untreated control phase. Both follicular ablation and hormone treatment shortened and decreased the variability in the interval to follicular wave emergence in bison, but wave emergence occurred earlier after follicular ablation.

  9. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K.

    2010-01-01

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  10. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    Science.gov (United States)

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  11. Impact of routine transvaginal ultrasound monitoring of cervical length in twins on administration of antenatal corticosteroids.

    Science.gov (United States)

    Marcellin, Louis; Senat, Marie Victoire; Benachi, Alexandra; Regis, Sophie; Cabrol, Dominique; Goffinet, François

    2017-05-24

    To evaluate whether routine measurement of cervical length (CL) by transvaginal ultrasound (TVU) in twin pregnancies can enable identification of women who will give birth before 34 weeks and require antenatal corticosteroids (ACSs), and whether it can limit their administration to women who will give birth later. Retrospective comparative study in two tertiary referral centers in France. Women with twin gestations followed in two tertiary university hospital maternity units and who delivered from January 1, 2007 to December 31, 2009 were included. In one center, TVU was targeted to women with cases of suspected preterm labor, while the other center used it monthly for all twin pregnancies. The main outcome measure was the administration of a full course of ACS to twins delivered before 34 weeks. Two hundred and seventy women were eligible in the "targeted use" group, and 296 women in the "routine use" group. The rate of administration of at least one full course of ACS for twins born before 34 weeks did not differ between the two groups (85.0% in the targeted use group and 90.0% in the routine use group, P=0.40), but the rate of such administration for those born after 34 weeks was lower in the targeted use group (25.7% vs. 81.2%, P<0.01). On adjusting for confounders using logistic regression modeling, no significant difference in ACS administration before 34 weeks was found between the two groups [adjusted odds ratio (aOR), 0.71, 95% confidence interval (CI), 0.39-1.30]. Routine monitoring performed every month of CL with TVU does not affect the rate of administration of ACS to twins born before 34 weeks, but is associated with a higher rate of such administration for those born later in the specific center of the study.

  12. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    Science.gov (United States)

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  13. Efficacy evaluation of laparoscopy assisted ultrasound guided radiofrequency ablation in the treatment of hepatocellular carcinoma beneath the diaphragm

    Directory of Open Access Journals (Sweden)

    Song WANG

    2017-06-01

    Full Text Available Objective To explore the feasibility, safety and efficacy of laparoscopy assisted ultrasound guided radiofrequency ablation (RFA in the treatment of hepatocellular carcinoma (HCC beneath the diaphragm. Methods Twenty- three consecutive patients with solitary HCC beneath the diaphragm were treated by laparoscopy assisted ultrasound guided RFA in the Chinese PLA General Hospital from January 2013 to March 2016. We observed the perioperative complications and followed- up long-term effect. Results All the 23 patients successfully underwent laparoscopy assisted ultrasound guided radiofrequency ablation. No serious complications such as massive hemorrhage, biliary fistula and severe pleural effusion, hemopneumothorax occurred in the patients during perioperative period. CT examination 2-3 days after the operation revealed that the tumor was completely covered by the ablation area. Besides, the survival condition was satisfactory during follow-up period of 9-38 months. Conclusion Laparoscopy-assisted ultrasound-guided radiofrequency ablation is effective and safe for HCC beneath the diaphragm. DOI: 10.11855/j.issn.0577-7402.2017.05.16

  14. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    Science.gov (United States)

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P 0.05). No analgesic was superadded and no other anesthesia methods were applied. No complications were detected perioperatively. Conclusions: The bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator are both effective and safe for bilateral hand/forearm surgery. However, the ultrasound-guided block may be more clinically beneficial because of its shorter performance time, rapid onset and higher patient satisfaction degree.

  15. Colecistectomía transvaginal (NOTES combinada con minilaparoscopia Transvaginal cholecystectomy (NOTES combined with minilaparoscopy

    Directory of Open Access Journals (Sweden)

    C. Dolz

    2007-12-01

    Full Text Available Objetivo: comunicar la primera colecistectomía transvaginal realizada en humanos en nuestro país. Pacientes y métodos: mujer de 35 años de edad con historia de cólicos hepáticos de repetición de etiología litiásica. La intervención la realizó un equipo multidisciplinar constituido por cirujanos, gastroenterólogos y ginecólogos. Consistió en crear un neumoperitoneo mediante una aguja de Veres colocada en el fondo umbilical con posterior colocación de un trócar de 5 mm. Se colocó un segundo trócar de 3 mm en el hipocondrio derecho. Se realizó una colpotomía y colocación de un trócar vaginal de 12 mm que permitió el paso de un videogastroscopio que alcanzó el hilio hepático. Resultados: se realizó la colecistectomía mediante la acción conjunta de instrumentos de trabajo que pasaron por las puertas de entrada de la minilaparoscopia y por el videogastroscopio. La extracción de la vesícula se realizó por vía transvaginal mediante el videogastroscopio. No aparecieron complicaciones postoperatorias siendo la paciente dada de alta al cabo de 24 horas. Conclusiones: la colecistectomía transvaginal mediante la acción conjunta de un equipo multidiscliplinar es posible y segura. La cirugía endoscópica transluminal a través de orificios naturales (NOTES, es una modalidad emergente que intenta ser menos invasiva, mejor tolerada y más respetuosa con el daño estético que la cirugía laparoscópica y probablemente será la puerta de entrada de innovaciones médicas y tecnológicas de gran trascendencia durante los próximos años.Objective: to report on the first transvaginal cholecystectomy performed on a human being in Spain. Patients and methods: a 35-year-old female with a history of recurrent bouts of biliary pain resulting from gallstones. A surgical procedure was performed by a multidisciplinary team composed of surgeons, gastroenterologists, and gynecologists. It involved creating a pneumoperitoneum by placing a

  16. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  17. Qualitative and quantitative analysis of women's perceptions of transvaginal surgery.

    Science.gov (United States)

    Bingener, Juliane; Sloan, Jeff A; Ghosh, Karthik; McConico, Andrea; Mariani, Andrea

    2012-04-01

    Prior surveys evaluating women's perceptions of transvaginal surgery both support and refute the acceptability of transvaginal access. Most surveys employed mainly quantitative analysis, limiting the insight into the women's perspective. In this mixed-methods study, we include qualitative and quantitative methodology to assess women's perceptions of transvaginal procedures. Women seen at the outpatient clinics of a tertiary-care center were asked to complete a survey. Demographics and preferences for appendectomy, cholecystectomy, and tubal ligation were elicited, along with open-ended questions about concerns or benefits of transvaginal access. Multivariate logistic regression models were constructed to examine the impact of age, education, parity, and prior transvaginal procedures on preferences. For the qualitative evaluation, content analysis by independent investigators identified themes, issues, and concerns raised in the comments. The completed survey tool was returned by 409 women (grouped mean age 53 years, mean number of 2 children, 82% ≥ some college education, and 56% with previous transvaginal procedure). The transvaginal approach was acceptable for tubal ligation to 59%, for appendectomy to 43%, and for cholecystectomy to 41% of the women. The most frequently mentioned factors that would make women prefer a vaginal approach were decreased invasiveness (14.4%), recovery time (13.9%), scarring (13.7%), pain (6%), and surgical entry location relative to organ removed (4.4%). The most frequently mentioned concerns about the vaginal approach were the possibility of complications/safety (14.7%), pain (9%), infection (5.6%), and recovery time (4.9%). A number of women voiced technical concerns about the vaginal approach. As in prior studies, scarring and pain were important issues to be considered, but recovery time and increased invasiveness were also in the "top five" list. The surveyed women appeared to actively participate in evaluating the technical

  18. Subacute posteromedial impingement of the ankle in athletes: MR imaging evaluation and ultrasound guided therapy

    International Nuclear Information System (INIS)

    Messiou, Christina; Robinson, Philip; O'Connor, Philip J.; Grainger, Andrew

    2006-01-01

    To describe the use of MR imaging and efficacy of ultrasound-guided steroid injection in the diagnosis and management of athletes with clinical posteromedial impingement of the ankle. A retrospective analysis of imaging findings on MR was undertaken in nine elite athletes with clinical posteromedial ankle impingement. MR studies from six professional athletes with posterolateral pain were also reviewed as an imaging control group. The two reviewing radiologists were blinded to the clinical details and the proportion of control and study subjects. The nine study athletes also underwent diagnostic ultrasound and ultrasound-guided injection of steroid and anaesthetic into the posteromedial capsular abnormality. Follow-up was by telephone interview. Posteromedial capsular thickening was seen only in athletes with posteromedial impingement (7/9). Posteromedial synovitis was present in all athletes with posteromedial impingement; however, posterior and posterolateral synovitis was also seen in these athletes. Mild posteromedial synovitis was present in two control athletes. Ultrasound identified abnormal posteromedial soft tissue thickening deep to tibialis posterior between the medial malleolus and talus in all nine athletes. After injection all athletes returned to their previous level of sport, with eight of the nine not experiencing any residual or recurrent symptoms. If MR imaging excludes significant coexistent abnormality, ultrasound can localise posteromedial soft tissue abnormality and guide injection therapy, allowing return to athletic activity without surgical intervention. (orig.)

  19. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  20. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    International Nuclear Information System (INIS)

    Davidson, J.; Jayaraman, S.

    2011-01-01

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  1. Guiding tissue regeneration with ultrasound in vitro and in vivo

    Science.gov (United States)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  2. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  3. Influence of 2-(18F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography on recurrent ovarian cancer diagnosis and on selection of patients for secondary cytoreductive surgery

    DEFF Research Database (Denmark)

    Risum, Signe; Høgdall, Claus; Markova, Elena

    2009-01-01

    physical examination, US, or increasing cancer antigen 125 (CA125) level (>50 U/mL or >15% above baseline level). Recurrent OC was diagnosed 58 times in 52 patients. The sensitivities of US, CT, and PET/CT for diagnosing recurrence were 66% (P = 0.003), 81% (P = 0.0001), and 97% (P ...The objective of this prospective study was to compare the sensitivities and the specificities of combined 2-(F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT), abdominal/transvaginal ultrasound (US), and CT for diagnosing recurrent ovarian cancer (OC......) and to evaluate the influence of PET/CT on referral of patients with solitary recurrence to secondary cytoreductive surgery. From April 2005 to November 2007, 60 patients were consecutively included to PET/CT 68 times. The inclusion criteria were remission of 3 months or longer and recurrent OC suspected from...

  4. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    Science.gov (United States)

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  5. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    Science.gov (United States)

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  6. Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyun; Hong, Seong; Sook; Kim, Jung Hoon; Park, Hyun Jeong; Chang, Yun Woo; Chang, A Ram [Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of); Kwon, Seok Beom [Hallym University College of Medicine, Chuncheon (Korea, Republic of)

    2012-06-15

    To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial marker implantations in 77 patients, which were performed from June 2008 through March 2011. Of 270 implantations, 104 were implanted in metastatic lymph nodes, 96 were in the liver, 39 were in the pancreas, and 31 were in the prostate. During and after the implantation, major and minor procedure-related complications were documented. We defined technical success as the implantation enabling adequate treatment planning and CT simulation. The major and minor complication rates were 1% and 21%, respectively. One patient who had an implantation in the liver suffered severe abdominal pain, biloma, and pleural effusion, which were considered as major complication. Abdominal pain was the most common complication in 11 patients (14%). Among nine patients who had markers inserted in the prostate, one had transient hematuria for less than 24 hours, and the other experienced transient voiding difficulty. Of the 270 implantations, 261 were successful (97%). The reasons for unsuccessful implantations included migration of fiducial markers (five implantations, 2%) and failure to discriminate the fiducial markers (three implantations, 1%). Among the unsuccessful implantation cases, six patients required additional procedures (8%). The symptomatic complications following ultrasound-guided percutaneous implantation of fiducial markers are relatively low. However, careful consideration of the relatively higher rate of migration and discrimination failure is needed when performing ultrasound-guided percutaneous implantations of fiducial markers.

  7. Sacral colpopexy versus transvaginal mesh colpopexy in obese patients.

    Science.gov (United States)

    McDermott, Colleen D; Park, Jean; Terry, Colin L; Woodman, Patrick J; Hale, Douglass S

    2013-05-01

    Obesity can predispose women to pelvic organ prolapse and can also affect the success of pelvic organ prolapse surgery. The purpose of this study was to compare the postoperative anatomical outcomes following sacral colpopexy (SC) and transvaginal mesh colpopexy in a group of obese women with pelvic organ prolapse. We conducted a retrospective cohort study of obese women who underwent SC (n = 56) or transvaginal mesh colpopexy (n = 35). Follow-up ranged from 6 to 12 months. Preoperative, perioperative, and postoperative variables were compared using Student t, Mann-Whitney U, and Fisher exact tests, and by analysis of covariance. The women in the SC group had significantly higher mean apical vaginal measurements (P transvaginal mesh colpopexy group. There were no significant differences between the groups for other postoperative outcomes, including mesh erosion, recurrent prolapse symptoms, dyspareunia, and surgical satisfaction (P > 0.05). In these 91 obese patients with pelvic organ prolapse, SC resulted in better anatomical outcomes than transvaginal mesh colpopexy. However, the two procedures had similar outcomes with regard to recurrent symptoms and surgical satisfaction.

  8. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  9. Ultrasound-Guided Multiple Peripheral Nerve Blocks in a Superobese Patient

    Directory of Open Access Journals (Sweden)

    Alper Kilicaslan

    2014-01-01

    Full Text Available The number of obese patients has increased dramatically worldwide. Morbid obesity is associated with an increased incidence of medical comorbidities and restricts the application choices in anesthesiology. We report a successfully performed combined ultrasound-guided blockade of the femoral, tibial, and common peroneal nerve in a superobese patient. We present a case report of a 31-year-old, ASA-PS II, super obese man (190 kg, 180 cm, BMI: 58 kg/m2 admitted to the emergency department with a type II segmental tibia shaft fracture and ankle dislocation after a vehicle accident. After two failed spinal anesthesia attempts, we decided to apply a femoral block combined with a sciatic block. Femoral blocks were successfully performed with US guided in-plane technique. Separate blocks of the tibial and common peroneal nerves were planned after the sciatic nerve could not be located due to the thick subcutaneous tissue. We performed a tibial nerve block at 2 cm above the popliteal crease and common peroneal nerve at the level of the fibular head with US guided in-plane technique. The blocks were successful and no block-related complications were noted. Ultrasound guidance allows new approaches for multiple peripheral nerve blocks with low local anesthetic doses in obese patients.

  10. Sleep Duration, Exercise, Shift Work and Polycystic Ovarian Syndrome-Related Outcomes in a Healthy Population: A Cross-Sectional Study.

    Science.gov (United States)

    Lim, Audrey J R; Huang, Zhongwei; Chua, Seok Eng; Kramer, Michael S; Yong, Eu-Leong

    2016-01-01

    Few studies have examined the associations between sleep duration, shiftwork, and exercise to the infrequent menstruation, hyperandrogenism, and ovarian morphological changes observed in women with polycystic ovarian syndrome (PCOS). To examine whether lifestyle factors, including short sleep duration, insufficient exercise, and shiftwork, alone or in combination, are associated with the reproductive and metabolic abnormalities typical of PCOS in a healthy population. Prospective cross-sectional study of 231 women, including healthcare workers recruited for an annual health screen, healthy referral patients from the Women's Clinic and volunteers from the university community at the National University Hospital, Singapore, from 2011 to 2015. The women completed a questionnaire, including their menstrual cycle length, sleep length, frequency of exercise and shift work. Hyperandrogenism (hirsutism score, testosterone, sex hormone binding globulin (SHBG)), ovarian morphology and function (anthral follicle count, ovarian volume, anti-mullerian hormone (AMH)), and metabolic measures (body mass index (BMI), waist hip ratio (WHR), blood pressure, fasting glucose, fasting insulin and fasting lipids) were examined through anthropometric measurements, transvaginal ultrasound scans, and blood tests. No significant associations were observed between shift work, exercise or sleep duration and the androgenic and ovarian measures that define PCOS. However, women reporting fewer than 6 hours of sleep were more likely to report abnormal (short or long) menstrual cycle lengths (OR = 2.1; 95% CI, 1.1 to 4.2). Women who reported fewer than 6 hours of sleep had increased fasting insulin levels (difference in means = 2.13; 95% CI, 0.27 to 3.99 mU/L) and higher odds of insulin resistance (OR = 2.58; CI, 1.16 to 5.76). Lack of regular exercise was associated with higher mean fasting insulin (difference in means = 2.3 mU/L; 95% CI, 0.5 to 4.1) and HOMA-IR (difference in means = 0.49; 95% CI

  11. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  12. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    Science.gov (United States)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  13. The role of ultrasound-guided triamcinolone injection in the treatment of de Quervain's disease: treatment and a diagnostic tool?

    NARCIS (Netherlands)

    Hajder, E.; de Jonge, M. C.; van der Horst, C. M. A. M.; Obdeijn, M. C.

    2013-01-01

    The purpose of this study was to describe the technique and usefulness of ultrasound-guided intrasheath injection of triamcinolone in the treatment of de Quervain's disease (dQD). Our study was retrospective in design. Seventy-one wrists of 62 patients who were treated with an ultrasound-guided

  14. Ultrasound-guided compression repair of pseudoaneurysms of brachial and femoral arteries - 2 cases-

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Choi, Yeon Hyeon; Kim, Ji Eun; Lee, Sang Hoon; Kim, Myung A; Kim, Tae Kyoung; Cho, Jae Min

    1994-01-01

    Ultrasound-guided compression repair of postcatherization pseudoaneurysm has been reported recently. We successfuly treated two cases of cardiac catherization-related pseudoaneurysms of brachial and femoral arteries with compression repair technique under color Doppler US-guidance. We regard US-guided compression repair as a saft and effective first-line treatment for catherization-related pseudoaneurysm

  15. Sexual function after transvaginal cholecystectomy

    DEFF Research Database (Denmark)

    Donatsky, Anders M; Jørgensen, Lars N; Meisner, Søren

    2014-01-01

    INTRODUCTION: Despite several benefits, patients are concerned that transvaginal cholecystectomy has a negative impact on sexual health. The objective of this systematic review was to assess the impact of transvaginal cholecystectomy on postoperative dyspareunia and sexual function. METHOD......: A literature search was performed in the PubMed and EMBASE databases. Papers reporting on postoperative dyspareunia, vaginal pain or discomfort, and sexual function were included. RESULTS: Seventeen papers reported on dyspareunia and vaginal pain or discomfort. Two papers reported a rate of de novo dyspareunia...... of 3.8% and 12.5%, respectively. One study reported a nonsignificant reduction in painful sexual intercourse and the remaining 14 reported no incidents of dyspareunia. Eight papers reported on sexual function. One paper using a nonvalidated questionnaire found impaired sexual function. The papers...

  16. Transvaginal uterosacral ligament hysteropexy: a retrospective feasibility study.

    Science.gov (United States)

    Milani, Rodolfo; Frigerio, Matteo; Manodoro, Stefano; Cola, Alice; Spelzini, Federico

    2017-01-01

    Uterine-sparing procedures could be attractive in patients concerned about preservation of fertility and change in corporeal image and sexuality. Transvaginal uterosacral hysteropexy can provide an alternative mesh-free technique for uterine suspension. This study aimed to evaluate the feasibility of transvaginal uterine suspension to uterosacral ligaments in terms of operative data, complications, midterm efficacy, and patient satisfaction. This retrospective study analyzed the first 20 cases of transvaginal hysteropexy through bilateral high uterosacral ligaments (modified Shull technique) performed in our Institution. Mean follow-up was 33.2 months. The procedure was performed in 84 ± 19 min ,and blood loss was 228 ± 139 ml. Three mild complications (15 %) were observed. Recurrence [Pelvic Organ Prolapse Quantification system (POP-Q) stage ≥ II was observed in five patients (25 %), and three of them (15 %) required reintervention. Mean Patient Global Impression of Improvement score was "much improved." Two woman (40 %) who had not fulfilled their childbearing desire obtained a pregnancy. Both underwent elective caesarean section at term. Transvaginal uterosacral hysteropexy appears a feasible mesh-free technique for apical support. This procedure can be indicated in women with the desire of preserving fertility or who prefer a uterine-sparing surgical option.

  17. MRI appearances of pure epithelial papillary serous borderline ovarian tumours

    International Nuclear Information System (INIS)

    Naqvi, J.; Nagaraju, E.; Ahmad, S.

    2015-01-01

    Borderline epithelial ovarian tumours (BOT) represent 15–20% of all non-benign ovarian epithelial neoplasms. Compared to malignant ovarian tumours, they usually present at a younger age and carry a far superior prognosis. Fertility-conserving surgery is an important treatment option for patients with BOT. Ultrasound and CT are both widely available and play roles in the initial investigation and staging of BOT, respectively. However, lack of soft-tissue contrast limits their ability to characterize BOT. MRI can facilitate recognition of pure epithelial serous BOT (SBOT), including the cystic papillary and surface papillary subtypes. An abundance of hyperintense papillary projections with low signal internal branching and ovarian stroma preservation with a hypointense ovarian capsular margin on T2-weighted imaging are features strongly suggestive of SBOT. In this review we will discuss the general morphological features of SBOT, the benefits and drawbacks of ultrasound and CT in the initial work-up, and the principal MRI features enabling recognition of surface papillary and cystic papillary SBOT

  18. Does obesity compromise ovarian reserve markers? A clinician's perspective.

    Science.gov (United States)

    Malhotra, Neena; Bahadur, Anupama; Singh, Neeta; Kalaivani, Mani; Mittal, Suneeta

    2013-01-01

    The aim of the study was to ascertain if increasing body mass index (BMI) adversely affects ovarian reserve among infertile women of Asian origin undergoing in vitro fertilization (IVF). This prospective study on 183 women was carried out in the infertility clinic of All India Institute of Medical Sciences, New Delhi, India. Blood hormonal assay in all patients including follicle-stimulating hormone (FSH), luteinizing hormone (LH) and inhibin B was performed on day 2/3 of a spontaneous cycle. A transvaginal ultrasonographic examination on day 2-5 of the menstrual cycle was done for antral follicle count (AFC) and ovarian volume. A correlation between BMI and ovarian reserve parameters like FSH, LH, inhibin B, antral follicle count and ovarian volume was noted. Age was comparable in the three BMI groups. The mean duration of infertility was 8.38 years. Compared to the normal weight, the overweight and obese women had a statistically significantly low inhibin B (p women had a significantly low AFC (p right side. Incorporating anti-mullerian hormone, a newer marker for ovarian reserve, may benefit these obese infertile women. Further work is required to elucidate the mechanisms underlying the effect of obesity on inhibin B as a marker of ovarian reserve in infertile women. The best marker to check the ovarian reserve is perhaps the woman's performance during an IVF cycle. However, considering the psychological and financial stress of the procedure, it may seem wise to consider counseling of obese women on their expected performance in the first cycle of IVF through such studies.

  19. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  20. Successful ongoing pregnancies after vitrification of oocytes.

    Science.gov (United States)

    Lucena, Elkin; Bernal, Diana Patricia; Lucena, Carolina; Rojas, Alejandro; Moran, Abby; Lucena, Andrés

    2006-01-01

    To demonstrate the efficiency of vitrifying mature human oocytes for different clinical indications. Descriptive case series. Cryobiology laboratory, Centro Colombiano de Fertilidad y Esterilidad-CECOLFES LTDA. (Bogotá, Colombia). Oocyte vitrification was offered as an alternative management for patients undergoing infertility treatment because of ovarian hyperstimulation syndrome, premature ovarian failure, natural ovarian failure, male factor, poor response, or oocyte donation. Mature oocytes were obtained from 33 donor women and 40 patients undergoing infertility treatment. Oocytes were retrieved by ultrasound-guided transvaginal aspiration and vitrified with the Cryotops method, with 30% ethylene glycol, 30% dimethyl sulfoxide, and 0.5 mol/L sucrose. Viability was assessed 3 hours after thawing. The surviving oocytes were inseminated by intracytoplasmic sperm injection. Fertilization was evaluated after 24 hours. The zygotes were further cultured in vitro for up to 72 hours until time of embryo transfer. Recovery, viability, fertilization, and pregnancy rates. Oocyte vitrification with the Cryotop method resulted in high rates of recovery, viability, fertilization, cleavage, and ongoing pregnancy. Vitrification with the Cryotop method is an efficient, fast, and economical method for oocyte cryopreservation that offers high rates of survival, fertilization, embryo development, and ongoing normal pregnancies, providing a new alternative for the management of female infertility.

  1. Ovarian Autoantibodies Predict Ovarian Cancer

    Science.gov (United States)

    2010-11-01

    Expression of thymidine 459 phosphorylase in epithelial ovarian cancer: correlation with angiogenesis, apoptosis , and 460 ultrasound-derived peak...trafficking, activation of S1P1 can promote or inhibit apoptosis of 41 immune cells depending on the balance of cytokines [7]. Knockout of S1P1 (LP(B1...EDG-1) in 42 mice is embryologically lethal [8]. S1P1 also has a role in inflammatory disease such as graft 43 versus host disease and multiple

  2. Ultrasound-guided Breast Biopsy in the Resource-limited Setting: An Initial Experience in Rural Uganda

    Directory of Open Access Journals (Sweden)

    Christopher R. Stark

    2017-06-01

    Full Text Available Purpose: To describe the methodology and initial experience behind creation of an ultrasoundguided percutaneous breast core biopsy program in rural Uganda. Methods and Materials: Imaging the World Africa (ITWA is the registered non-governmental organization division of Imaging the World (ITW, a not-for-profit organization whose primary aim is the integration of affordable high-quality ultrasound into rural health centers. In 2013, ITWA began the pilot phase of an IRB-approved breast care protocol at a rural health center in Uganda. As part of the protocol’s diagnostic arm, an ultrasound-guided percutaneous breast core biopsy training curriculum was implemented in tandem with creation of regionally supplied biopsy kits. Results: A surgeon at a rural regional referral hospital was successfully trained and certified to perform ultrasound-guided percutaneous breast core biopsies. Affordable and safe biopsy kits were created using locally available medical supplies with the cost of each kit totaling $10.62 USD. Conclusion: Successful implementation of an ultrasound-guided percutaneous breast core biopsy program in the resource-limited setting is possible and can be made sustainable through incorporation of local health care personnel and regionally supplied biopsy materials. Our hope is that ITWA’s initial experience in rural Uganda can serve as a model for similar programs in the future.

  3. The ultrasound-guided retrolaminar block: volume-dependent injectate distribution

    Directory of Open Access Journals (Sweden)

    Damjanovska M

    2018-02-01

    Full Text Available Marija Damjanovska,1 Tatjana Stopar Pintaric,1,2 Erika Cvetko,2 Kamen Vlassakov3 1Clinical Department of Anesthesiology and Intensive Therapy, University Medical Centre Ljubljana, Ljubljana, Slovenia; 2Institute of Anatomy, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia; 3Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA Purpose: The ultrasound-guided retrolaminar block is one of the newer and simpler alternatives to the traditional, often technically challenging, paravertebral (PV block. Its feasibility, safety, and efficacy have already been clinically demonstrated in patients with multiple rib fractures using higher volumes of local anesthetic, when compared with the traditional approach. The primary aim of this observational anatomical study was to assess the spread of local anesthetic from the retrolaminar injection point to the PV space and its volume dependence. Second, we assessed the incidence of epidural and contralateral PV spread in the both groups.Methods: Ten fresh porcine cadavers were randomized into 2 groups (n=5 each to receive ultrasound-guided retrolaminar injections at Th4-Th5 level with either 10 mL (low-volume group or 30 mL (high-volume group of 2% lidocaine and methylene blue mixture. After the procedure, the cadavers were dissected and frozen. Cross-section cuts (~1 cm thick were performed to evaluate the injectate spread.Results: In the high-volume group, injectate spread from the retrolaminar to the PV space was observed in all specimens (5 out of 5; 100%, while in the low-volume group, no apparent spread to the PV space was found (0 out of 5; 0%. No epidural or contralateral PV spread was observed in any of the specimens.Conclusion: Following ultrasound-guided retrolaminar injections in fresh porcine cadavers, injectate spread from the retrolaminar tissue plane to the PV space is strongly volume dependent

  4. Laparoscopic ovarian drilling versus GnRH antagonist combined with cabergoline as a prophylaxis against the re-development of ovarian hyperstimulation syndrome.

    Science.gov (United States)

    Seyam, Emaduldin; Hefzy, Enas

    2018-07-01

    The aim of this work was to investigate the value of laparoscopic ovarian drilling (LOD) compared with GnRH antagonist flexible protocol combined with cabergoline (Cb), as a prophylaxis against the re-development of ovarian hyperstimulation syndrome (OHSS) in women with clomiphene citrate-resistant polycystic ovary disease (CCR-PCOD) who had severe OHSS before in a previous ICSI cycle. It is a prospective controlled study, where 250 CCR-PCOD women (n = 250) with a history of severe OHSS before, had been recruited for the study. LOD had been performed for 120 (n = 120) of the recruited women before ovarian induction, and considered as group A. GnRH antagonist (Cetrotide 0.25 mg) was added when a leading follicle reaches 14-16 mm combined with oral Cb in a dose 0.5 mg a day before hCG, and for 8 d for another 130 (n = 130) women, and considered as group B. Pregnancy was diagnosed with BhCG level ≥25 IU/L, ± 14 d after embryo transfer, followed with transvaginal ultrasound scanning (TVS) 2 weeks later to confirm intra-uterine pregnancy (IUP). Women were followed up weekly for 3 months for the possible development of any signs and symptoms of OHSS. None of the participants in group A developed severe OHSS, and only six women (5%) developed mild to moderate OHSS. The incidence of severe OHSS was significantly higher (n = 3, 15%) in group B compared with group A (p < .001). Another (n = 17, 13.3%) women in group B developed mild to moderate OHSS. The probability of developing severe OHSS was also significantly higher in group B as well (p = .031). Pregnancy rate (PR) was significantly higher in group A more than group B (67% versus 39%, respectively), and all were single intrauterine pregnancies (IUP) and all developed after fresh embryo transfer (ET), compared with frozen embryo transfer (FET) which was performed in 42 cases in group B after postponing ET due to significantly severe OHSS developed. LOD could be considered

  5. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  6. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  7. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  9. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  10. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    NARCIS (Netherlands)

    Rutten, M.J.; Collins, J.M.; Maresch, B.J.; Smeets, J.H.R.; Janssen, C.M.; Kiemeney, L.A.L.M.; Jager, G.J.

    2009-01-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and

  11. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  12. Transvaginal ultrasound versus magnetic resonance imaging for preoperative assessment of myometrial infiltration in patients with endometrial cancer: a systematic review and meta-analysis

    Science.gov (United States)

    2017-01-01

    Objective To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. Methods An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%–82%) and 82% (95% CI=75%–93%) for TVS, and 83% (95% CI=76%–89%) and 82% (95% CI=72%–89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. Conclusion MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. PMID:29027404

  13. Effectiveness of ultrasound-guided injections combined with shoulder exercises in the treatment of subacromial adhesive bursitis.

    Science.gov (United States)

    Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia

    2012-05-01

    The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.

  14. The Distribution of Stroma and Antral Follicles Differs between Insulin-Resistance and Hyperandrogenism-Related Polycystic Ovarian Syndrome

    DEFF Research Database (Denmark)

    Alviggi, Carlo; Conforti, Alessandro; De Rosa, Pasquale

    2017-01-01

    groups based on specific transvaginal ultrasound parameters: subjects with more than half of the follicles measuring between 5 and 9 mm in diameter, an ultrasonographic determined stroma/total area (S/A) > 0.34 and a "necklace" sign of antral follicles (Group A); and subjects with more than half...... of the antral follicles measuring between 2 and 4 mm in diameter, an S/A ≤ 0.34; no "necklace" sign but ubiquitously distributed follicles determined by ultrasound (Group B). The association between these ultrasound patterns and the presence of insulin resistance was also evaluated. RESULTS: Seventy...

  15. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  16. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    Science.gov (United States)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  17. Ultrasound-guided interstitial laser photocoagulation of an autonomous thyroid nodule

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Hegedüs, Laszlo

    2003-01-01

    effects and often necessitates multiple treatment sessions. We present a case of a 17-year-old female successfully treated with ultrasound (US)-guided percutaneous interstitial laser photocoagulation (ILP) for an AFTN. Initially, she had a serum thyrotropin (TSH) of 0.01 mU/L and normal peripheral thyroid.......9 mL (40% reduction) without further alterations during an additional 9 months of follow-up. Side effects were transient thyrotoxicosis and local pain as seen with PEI. To our knowledge, this is the first reported case of ILP used in a patient with a pretoxic thyroid nodule. US-guided thermic tissue...

  18. Ultrasound-guided brachial plexus block: a study on 30 patients

    Directory of Open Access Journals (Sweden)

    Amiri HR

    2009-05-01

    Full Text Available "n Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Successful brachial plexus blocks rely on proper techniques of nerve localization, needle placement, and local anesthetic injection. Standard approaches used today (elicitation of paresthesia or nerve-stimulated muscle contraction, unfortunately, are all "blind" techniques resulting in procedure-related pain and complications. Ultrasound guidance for brachial plexus blocks can potentially improve success and complication rates. This study presents the ultrasound-guided brachial plexus blocks for the first time in Iran in adults and pediatrics. "n"n Methods: In this study ultrasound-guided brachial plexus blocks in 30 patients (25 adults & 5 pediatrics scheduled for an elective upper extremity surgery, are introduced. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. Besides basic variables, block approach, block time, postoperative analgesia duration (VAS<3 was considered as target pain control opioid consumption during surgery, patient satisfaction and block related complications were reported

  19. Ovarian and uterine maturity assessed by pelvic ultrasound scanning in adolescent girls with anorexia nervosa at the start of treatment – correlation with the history of menstruation

    Directory of Open Access Journals (Sweden)

    Gabriela Jagielska

    2010-12-01

    Full Text Available In females, absence of at least three consecutive menstrual cycles when otherwise expected to occur or cessation of pubescence (primary and secondary amenorrhea are the symptoms of anorexia nervosa, secondary to hypogonadotropic hypogonadism. Disturbances in sexual organs are seen in inappropriate for age pelvic ultrasound scanning. The aim of the study was to determine the ovarian and uterine maturity at the onset of anorexia nervosa (AN in adolescence, using pelvic ultrasound scanning, and their relations to clinical factors describing the course of AN. Material and method: The group consisted of 38 adolescent girls with anorexia nervosa diagnosed acc. to ICD-10 criteria – mean age 14.3±2.1 years, mean age at the beginning of AN symptoms 13±2.3 years, mean BMI 14±1.6 kg/m2. On initial assessment, all girls underwent physical examination, clinical interview concerning AN symptoms and pelvic ultrasound scanning. Results: Sixteen patients (42% had primary amenorrhea. In 32% of patients cessation of menses occurred before a significant decrease in weight. Ovarian and uterine volumes significantly below the expected were found in 11 and 15 patients with secondary amenorrhea, respectively. The varian and uterine maturity was related to shorter duration of amenorrhea and longer duration of adequate menstruation before the onset of AN. There were no BMI differences between the groups with more and less mature ultrasound picture.

  20. Neuroprotective effects of ultrasound-guided nerve growth factor injections after sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Hong-fei Li

    2015-01-01

    Full Text Available Nerve growth factor (NGF plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound (HFU is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.

  1. Ultrasonic study of ovarian morphology in patients with hypergonadotropic amenorrhea relationship with serum FSH, LH, E2 levels

    International Nuclear Information System (INIS)

    Zhao Jinping; Xiang Hong; Zhou Chunmin

    2004-01-01

    Objective: To study the morphologic changes of ovary with transvaginal ultrasonography in patients with hypergonadotropic amenorrhea as well as the relationship between the type of ovary and serum FSH, LH, E 2 levels. Methods: Transvaginal ultrasonic examination of ovary was performed in 38 patients with hypergonadotropic amenorrhea and 36 controls, serum levels of FSH, LH, E 2 were simultaneously determined with RIA. Results: Morphologically, all the 38 pairs of ovaries in the patients were significantly smaller than those in the controls (as represented by the transverse diameter and antero-posterior diameter, P 2 levels in these two type of patients were not much different, but the mean ovarian size in the small follicular type was significantly larger than that in the non-follicular type (P<0.01). Conclusion: Transvaginal ultrasonography is very helpful for the differential diagnosis of the type of ovary in patients with hypergonadotropic amenorrhea, providing guidelines for therapy. The accuracy is even superior to that by laparoscopic biopsy. In this study, the serum FSH level is not diagnostic. (authors)

  2. [Role of ultrasound in elective abortions].

    Science.gov (United States)

    Wylomanski, S; Winer, N

    2016-12-01

    Ultrasound plays a fundamental role in the management of elective abortions. Although it can improve the quality of post-abortion care, it must not be an obstacle to abortion access. We thus studied the role of ultrasound in pregnancy dating and possible alternatives and analyzed the literature to determine the role of ultrasound in post-abortion follow-up. During an ultrasound scan, the date of conception is estimated by measurement of the crown-rump length (CRL), defined by Robinson, or of the biparietal diameter (BPD), as defined by the French Center for Fetal Ultrasound (CFEF) after 11 weeks of gestation (Robinson and CFEF curves) (grade B). Updated curves have been developed in the INTERGROWTH study. In the context of abortion, the literature recommends the application of a safety margin of 5 days, especially when the CRL and/or BPD measurement indicates a term close to 14 weeks (that is equal or below 80 and 27mm, respectively) (best practice agreement). Accordingly, with the ultrasound measurement reliable to±5 days when its performance meets the relevant criteria, an abortion can take place when the CRL measurement is less than 90mm or the BPD less than 30mm (INTERGROWTH curves) (best practice agreement). While a dating ultrasound should be encouraged, its absence is not an obstacle to scheduling an abortion for women who report that they know the date of their last menstrual period and/or of the at-risk sexual relations and for whom a clinical examination by a healthcare professional is possible (best practice agreement). In cases of intrauterine pregnancy of uncertain viability or of a pregnancy of unknown location, without any particular symptoms, the patient must be able to have a transvaginal ultrasound to increase the precision of the diagnosis (grade B). Various reviews of the literature on post-abortion follow-up indicate that the routine use of ultrasound during instrumental abortions should be avoided (best practice agreement). If it becomes

  3. Transvaginal sonographic findings of the ectopic pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Soon Ae; Youn, Chang Seon; Han, Sei Yul; Cho, Joo Youn; Chang, Sang Sik; Cha, Kwang Yul; Cha, Kyung Sub [Cha Women' s Hospital, Sungnam (Korea, Republic of)

    1989-08-15

    Transvaginal(TV) sonography uses high-frequency transducer and allows access to the uterus and adnexa, provides better resolution and more accurate diagnosis of ectopic pregnancy. To determine the value and the utility of TV sonography for a suspected ectopic pregnancy, we studied 56 women during 4 months from January to April 1989. Of 56 patients 46 had an surgically confirmed ectopic pregnancy, 5 had not an ectopic pregnancy and 5 had not follow up. TV sonography provides definite sonographic diagnosis of ectopic pregnancy including an extrauterine gestational sac 34 cases(74%), extrauterine embryo 9 caes(19.7%), hematosalpinx 10 cases(21.7%). Overall adnexal mass was detected in 38 cases(82.6%) at initial TV sonography and in 44 cases(95.6%) at follow up TV sonography. Additional findings were uterine decidual reaction 19 cases(41.3%), pseudo G-sac 4 cases(8.7%), cul-de-sac fluid 42 cases(91.2%). Follow-up TV sonography showed newly developed or growing adnexal mass in 8 among 9 cases. False positive 5 cases were two ovarian cysts, one incomplete abortion, two parametrial thickening due to previous ectopic pregnancy and salpingectomy. TV sonography may improve the govality of patient management by early diagnosis and early surgical treatment, so may preserve fertility. In conclusion, we may suggest that TV sonography is an integral part of diagnostic modality in suspected ectopic pregnancy.

  4. Transvaginal sonographic findings of the ectopic pregnancy

    International Nuclear Information System (INIS)

    Jun, Soon Ae; Youn, Chang Seon; Han, Sei Yul; Cho, Joo Youn; Chang, Sang Sik; Cha, Kwang Yul; Cha, Kyung Sub

    1989-01-01

    Transvaginal(TV) sonography uses high-frequency transducer and allows access to the uterus and adnexa, provides better resolution and more accurate diagnosis of ectopic pregnancy. To determine the value and the utility of TV sonography for a suspected ectopic pregnancy, we studied 56 women during 4 months from January to April 1989. Of 56 patients 46 had an surgically confirmed ectopic pregnancy, 5 had not an ectopic pregnancy and 5 had not follow up. TV sonography provides definite sonographic diagnosis of ectopic pregnancy including an extrauterine gestational sac 34 cases(74%), extrauterine embryo 9 caes(19.7%), hematosalpinx 10 cases(21.7%). Overall adnexal mass was detected in 38 cases(82.6%) at initial TV sonography and in 44 cases(95.6%) at follow up TV sonography. Additional findings were uterine decidual reaction 19 cases(41.3%), pseudo G-sac 4 cases(8.7%), cul-de-sac fluid 42 cases(91.2%). Follow-up TV sonography showed newly developed or growing adnexal mass in 8 among 9 cases. False positive 5 cases were two ovarian cysts, one incomplete abortion, two parametrial thickening due to previous ectopic pregnancy and salpingectomy. TV sonography may improve the govality of patient management by early diagnosis and early surgical treatment, so may preserve fertility. In conclusion, we may suggest that TV sonography is an integral part of diagnostic modality in suspected ectopic pregnancy

  5. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  6. Massive ovarian edema, due to adjacent appendicitis.

    Science.gov (United States)

    Callen, Andrew L; Illangasekare, Tushani; Poder, Liina

    2017-04-01

    Massive ovarian edema is a benign clinical entity, the imaging findings of which can mimic an adnexal mass or ovarian torsion. In the setting of acute abdominal pain, identifying massive ovarian edema is a key in avoiding potential fertility-threatening surgery in young women. In addition, it is important to consider other contributing pathology when ovarian edema is secondary to another process. We present a case of a young woman presenting with subacute abdominal pain, whose initial workup revealed marked enlarged right ovary. Further imaging, diagnostic tests, and eventually diagnostic laparoscopy revealed that the ovarian enlargement was secondary to subacute appendicitis, rather than a primary adnexal process. We review the classic ultrasound and MRI imaging findings and pitfalls that relate to this diagnosis.

  7. MR-guided focused ultrasound: a potentially disruptive technology.

    Science.gov (United States)

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  8. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  9. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    Science.gov (United States)

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine ( Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine ( Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US...transducer (L11-4v, Verasonics Inc.) and build a housing which effectively couples fiber optic light delivery. o What opportunities for training and

  10. Contrast ultrasound-guided photothermal therapy using gold nanoshelled microcapsules in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shumin [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Ordos Center Hospital, Ordos, Inner Mongolia 017000 (China); Dai, Zhifei [Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ke, Hengte [Nanomedicine and Biosensor Laboratory, School of Life Science and Technology, Harbin Institute of Technology, Harbin 150001 (China); Qu, Enze [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Qi, Xiaoxu; Zhang, Kuo [Department of Laboratory Animal Science, Peking University Health Science Center, Beijing 100019 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China)

    2014-01-15

    Objectives: The purpose of this study was to test whether dual functional gold nano-shelled microcapsules (GNS-MCs) can be used as an ultrasound imaging enhancer and as an optical absorber for photothermal therapy (PTT) in a rodent model of breast cancer. Methods: GNS-MCs were fabricated with an inner air and outer gold nanoshell spherical structure. Photothermal cytotoxicity of GNS-MCs was tested with BT474 cancer cells in vitro and non-obese diabetes-SCID (NOD/SCID) mice with breast cancer. GNS-MCs were injected into the tumor under ultrasound guidance and treated with near-infrared (NIR) laser irradiation. The photothermal ablative effectiveness of GNS-MCs was evaluated by measuring the surface and internal temperature of the tumor as well as the size of the tumor using histological confirmation. Results: NIR laser irradiation resulted in significant tumor cell death in GNS-MCs-treated BT474 cells in vitro. GNS-MCs were able to serve as an ultrasound enhancer to guide the intratumoral injection of GNS-MCs and ensure their uniform distribution. In vivo studies revealed that NIR laser irradiation increased the intratumoral temperature to nearly 70 °C for 8 min in GNS-MCs-treated mice. Tumor volumes decreased gradually and tumors were completely ablated in 6 out of 7 mice treated with GNS-MCs and laser irradiation by 17 days after treatment. Conclusion: This study demonstrates that ultrasound-guided PTT with theranostic GNS-MCs is a promising technique for in situ treatment of breast cancer.

  11. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  12. Radiofrequency ablation guided by contrast-enhanced ultrasound for hepatic malignancies: Preliminary results

    International Nuclear Information System (INIS)

    Dong, Y.; Wang, W.-P.; Gan, Y.-H.; Huang, B.-J.; Ding, H.

    2014-01-01

    Aim: To evaluate whether contrast-enhanced ultrasound (CEUS)-guided radiofrequency ablation (RFA) can be performed effectively in small hepatic malignancies that are invisible or poorly visualized at traditional grey-scale ultrasonography (US). Materials and methods: The institutional ethics committee approved the study, and all patients provided written informed consent before their enrolment. The study focused on 55 patients (43 men, 12 women, age 57.4 ± 10.9 years) with 60 hepatic lesions from May 2010 to March 2011. All lesions were treated with multipolar radiofrequency ablation (RFA). During the RFA procedure, with the injection of ultrasound contrast agent (sulphur hexafluoride; SonoVue, Bracco Imaging Spa, Milan, Italy), RFA was conducted under CEUS guidance when the optimal depiction of a lesion was obtained. Artificial pleural effusions were used in those cases obstructed by the lungs. Twenty-four hours after RFA, contrast-enhanced MRI was used as the reference standard to evaluate the primary effectiveness rate and complete tumour necrosis. The follow-up time was 12–24 months (median 15 months). Results: Among 60 hepatic malignancies, CEUS detected 57 lesions (95%), which was higher than that at US (26.6%). Artificial pleural effusions were performed in three cases, resulting in the detection of three additional lesions. The insertion of RFA electrodes was monitored by CEUS in all lesions. Immediately after RFA, complete tumour necrosis were achieved in all 60 lesions as apparent at MRI, for a primary effectiveness rate of 100%. Conclusion: CEUS-guided RFA is a promising technique for targeting and improving the efficiency of treatment of hepatic malignancies. - Highlights: • CEUS guided RFA improved the detectability of hepatic malignancies indistinctive on gray-scale ultrasound. • Pre-operation CEUS helped localization of indistinctive hepatic malignancies. • CEUS guided RFA of hepatic malignancies achieved a more complete ablation

  13. Ultrasound-guided peripheral and truncal blocks in pediatric patients

    Directory of Open Access Journals (Sweden)

    Mohamed Bilal Delvi

    2011-01-01

    Full Text Available Ultrasound has added a feather in the cap of the anesthesiologists as real-time nerve localization and drug deposition around the nerve structure under real-time guidance is now a reality, as the saying "seeing is believing" has been proven true with the advent of ultrasound in anesthesia. Pediatric patients are a unique group regarding their anatomical and physiological features in comparison with adults; regional blocks in adults with the anatomical landmark and surface marking are almost uniform across the adult population. The landmark technique in pediatric patients is not reliable in all patients due to the variability in the age and size; the advent of ultrasound in assisting nerve localization has changed the way regional blocks are achieved in children and the range of blocks performed on adults can now be performed on pediatric patients; with advances in the technology and dexterity of ultrasound equipment, the chances of success of blocks has increased with a smaller dose of the local anesthetic in comparison to the traditional methods. Anesthesiologists are now able to perform blocks with more accuracy and avoid complications like intravascular injection and injury to the pleura and peritoneum during routine practice with the assistance of high-frequency transducers and top of the range portable ultrasound machines; catheters can be inserted to provide a continuous analgesia in the postoperative period. This review article describes the common peripheral blocks in pediatric patients; the readers are encouraged to gain experience by attending workshops, hands-on practice under supervision, and conduct random controlled trials pertaining to ultrasound-guided blocks in the pediatric age group. The recent literature is encouraging and further research is promising; a wide range of blocks being described in detail by many prominent experts from all over the world.

  14. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  15. A clinical assessment tool for ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    Sultan, S F

    2012-05-01

    Competency in anesthesia traditionally has been determined subjectively in practice. Optimal training in procedural skills requires valid and reliable forms of assessment. The objective was to examine a procedure-specific clinical assessment tool for ultrasound-guided axillary brachial plexus block for inter-rater reliability and construct validity in a clinical setting.

  16. Intra-articular distribution pattern after ultrasound-guided injections in wrist joints of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Boesen, Mikael; Jensen, Karl Erik; Torp-Pedersen, Søren

    2007-01-01

    OBJECTIVE: To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA). METHODS: An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg...... with the MRI OMERACT synovitis score (r=0.60, p=0.014), but not with the erosions, bonemarrow oedema scores or any clinical parameters. CONCLUSION: The distribution of contrast on MRI showed patient specific and random patterns after IA injections in active RA wrist joints. The degree of distribution increased...

  17. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  18. Role of ultrasound-guided continuous brachial plexus block in the management of neonatal ischemia in upper limb

    Directory of Open Access Journals (Sweden)

    Vrushali C Ponde

    2012-01-01

    Full Text Available Neonatal upper limb ischemia due to accidental arterial damage remains a major concern, which can lead to devastating complications if untreated. The primary objective of this case report is to emphasize the role of continuous infraclavicular brachial plexus block, the issues related with block performance in an ischemic hand, and the importance of ultrasound guidance in this particular case scenario. A 1.1 kg infant suffered from distal forearm ischemia due to accidental arterial damage, which was treated with brachial plexus block. An ultrasound-guided single shot block with 0.5 mL/kg of 0.25% bupivacaine was followed by ultrasound-guided catheter placement in the target area. A continuous infusion of 0.03% of bupivacaine at the rate of 0.5 mL/kg/hr (approx. 0.15 mg/kg/h of bupivacaine was administered for 36 h. This treatment resulted in reversal of ischemia. Permanent ischemic damage was eventually confined to the tips of 4 fingers. We conclude that ultrasound-guided continuous infraclavicular block has a therapeutic role to play in the treatment of hand ischemia due to arterial damage and subsequent arterial spasm in neonates with added benefits.

  19. MRI, PET/CT and ultrasound in the preoperative staging of endometrial cancer - A multicenter prospective comparative study

    DEFF Research Database (Denmark)

    Antonsen, Sofie Leisby; Jensen, Lisa Neerup; Loft, Annika

    2012-01-01

    OBJECTIVES: The aim of this prospective multicenter study was to evaluate and compare the diagnostic performance of PET/CT, MRI and transvaginal two-dimensional ultrasound (2DUS) in the preoperative assessment of endometrial cancer (EC). METHODS: 318 consecutive women with EC were included when...

  20. Transvaginal organ extraction: potential for broad clinical application.

    Science.gov (United States)

    Jacobsen, Garth R; Barajas-Gamboa, Juan S; Coker, Alisa M; Cheverie, Joslin; Macias, C Aitor; Sandler, Bryan J; Talamini, Mark A; Horgan, Santiago

    2014-02-01

    Natural orifice transluminal endoscopic surgery procedures have evolved over the past few years. A transvaginal approach is a promising alternative for intraperitoneal procedures. Our objective was to evaluate the safety and feasibility of transvaginal organ extraction. This institutional review board-approved protocol involved retrospective review of an ongoing prospective study. Female subjects who presented to our hospital for elective cholecystectomy, appendectomy, or sleeve gastrectomy were offered participation in the study. Eligible patients met the following criteria: age between 18 and 75, diagnosis of gallbladder disease, acute appendicitis, or morbid obesity who desired surgical treatment. A hybrid transvaginal natural orifice approach was used in this series. Thirty-four women underwent transvaginal organ extraction between September 2007 and January 2012. The mean age was 40 ± 12.1 years (range 23-63 years). The mean body mass index was 27 ± 6.4 kg/m(2) (range 16-43 kg/m(2)). All patients had an American Society of Anesthesiologists classification of two or below. The mean operative time for cholecystectomy, appendectomy, and sleeve gastrectomy was 90, 71, and 135 min, respectively. There were no conversions to open operation and no intraoperative complications. The mean hospital stay was 2 days for all cases. Patients were followed for a mean of 24 months (range 1-61 months). There were two pregnancies and two successful vaginal deliveries. Six patients (18 %) had minor complaints of spotting or heavy menses in the immediate postoperative period that resolved with conservative measures. There were no abdominal wall complications. There were no long-term complications and no mortalities. This initial experience suggests that this surgical approach is safe, does not increase length of stay, and has no long-term vaginal complications. Given this attractive profile, a transvaginal approach may prove to be a superior mode of organ extraction

  1. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    Science.gov (United States)

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  2. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  3. Minimum Effective Volume of Lidocaine for Ultrasound-Guided Costoclavicular Block.

    Science.gov (United States)

    Sotthisopha, Thitipan; Elgueta, Maria Francisca; Samerchua, Artid; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Gordon, Aida; Finlayson, Roderick J; Tran, De Q

    This dose-finding study aimed to determine the minimum effective volume in 90% of patients (MEV90) of lidocaine 1.5% with epinephrine 5 μg/mL for ultrasound-guided costoclavicular block. Using an in-plane technique and a lateral-to-medial direction, the block needle was positioned in the middle of the 3 cords of the brachial plexus in the costoclavicular space. The entire volume of lidocaine was deposited in this location. Dose assignment was carried out using a biased-coin-design up-and-down sequential method, where the total volume of local anesthetic administered to each patient depended on the response of the previous one. In case of failure, the next subject received a higher volume (defined as the previous volume with an increment of 2.5 mL). If the previous patient had a successful block, the next subject was randomized to a lower volume (defined as the previous volume with a decrement of 2.5 mL), with a probability of b = 0.11, or the same volume, with a probability of 1 - b = 0.89. Success was defined, at 30 minutes, as a minimal score of 14 of 16 points using a sensorimotor composite scale. Patients undergoing surgery of the elbow, forearm, wrist, or hand were prospectively enrolled until 45 successful blocks were obtained. This clinical trial was registered with ClinicalTrials.gov (ID NCT02932670). Fifty-seven patients were included in the study. Using isotonic regression and bootstrap confidence interval, the MEV90 for ultrasound-guided costoclavicular block was estimated to be 34.0 mL (95% confidence interval, 33.4-34.4 mL). All patients with a minimal composite score of 14 points at 30 minutes achieved surgical anesthesia intraoperatively. For ultrasound-guided costoclavicular block, the MEV90 of lidocaine 1.5% with epinephrine 5 μg/mL is 34 mL. Further dose-finding studies are required for other concentrations of lidocaine, other local anesthetic agents, and multiple-injection techniques.

  4. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  5. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  6. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    Science.gov (United States)

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); phydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Transient sexual precocity and ovarian cysts.

    OpenAIRE

    Lyon, A J; De Bruyn, R; Grant, D B

    1985-01-01

    Nine girls presenting under the age of 7 years with unsustained sexual precocity are described. Large ovarian cysts were detected by ultrasound in three and laparotomy in one. In two girls the symptoms resolved after surgical removal of the cyst; the other seven had spontaneous remission of symptoms, but in two of these transient breast development and bleeding recurred: further ovarian cyst formation was found in one of these patients. Endocrine studies performed before resolution of the cys...

  8. Diagnosis and management of an immature teratoma during ovarian stimulation: a case report

    Directory of Open Access Journals (Sweden)

    Douay-Hauser Nathalie

    2011-11-01

    Full Text Available Abstract Introduction The discovery of a mature teratoma (dermoid cyst of the ovary during ovarian stimulation is not a rare event. Conversely, we could not find any reported cases of immature teratoma in such a situation. Clinical and ultrasound arguments for this immature form are scarcely or poorly evaluated. Case Presentation We describe the case of a 31-year-old Caucasian woman with primary infertility, who developed an immature teratoma during an in vitro fertilization ovarian stimulation cycle. Conclusions Ultrasound signs of an atypical cyst during ovarian stimulation allowed us to adopt a careful medical attitude and to adapt the required surgical oncological treatment.

  9. Unusual presentation of antenatal ovarian torsion: free-floating abdominal cysts. Our experience and surgical management.

    Science.gov (United States)

    Zampieri, Nicola; Scirè, Gabriella; Zambon, Carla; Ottolenghi, Alberto; Camoglio, Francesco Saverio

    2009-04-01

    Abdominal cystic formations in newborns are relatively common and often diagnostic suspicion arises before birth as a result of ultrasound scans carried out during pregnancy. Prenatal ovarian torsion is a rare condition very difficult to manage in the first days of life. We report and discuss the management of prenatal ovarian torsion with a free-floating abdominal cyst detected on prenatal ultrasound. We recorded the cases of antenatal abdominal cysts detected on ultrasound at the Department of Antenatal Diagnosis between January 2003 and January 2007. Only patients with a free-floating cyst were included in the study. Clinical and surgical findings were then recorded. Two out of 57 patients underwent surgery for a free-floating abdominal cyst during the second day of life. Postnatal ultrasound, Doppler ultrasound, and laparoscopic exploration were useful to identify an unusual presentation of antenatal ovarian torsion with a complete atresia of the Fallopian tube. The cases reported in this study suggest that a good clinical approach to all cases of abdominal cysts detected on prenatal ultrasound scans require postnatal Doppler and abdominal ultrasound with a laparoscopic exploration. Free-floating abdominal cysts are rare but, at the same time, strictly correlated with autoamputation of the ovary/Fallopian tube complex.

  10. Point-of-Care Ultrasound-Guided Percutaneous Cannulation of Extracorporeal Membrane Oxygenation: Make it Simple.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Joo, Ki Hyuk; You, Yeon Ho; Ryu, Seung; Lee, Jin Woong; Kim, Seung Whan

    2017-12-30

    Cannulation of the great vessels is required for extracorporeal membrane oxygenation (ECMO). Currently, there is no guideline for optimal imaging modalities during percutaneous cannulation of ECMO. The purpose of this study was to describe percutaneous cannulation guided by point-of-care ultrasound (POCUS) for ECMO and compare it with fluoroscopy and landmark guidance. Three groups (POCUS-, fluoroscopy-, and landmark-guided) of percutaneous cannulation for ECMO were analyzed retrospectively in a tertiary academic hospital. In the POCUS-guided group, visual confirmation of guidewire and cannula by ultrasound in both the access and return cannula were essential for successful cannulation. Fluoroscopy- and landmark-guided groups were cannulated with the conventional technique. A total of 128 patients were treated by ECMO during the study period, of which 94 (73.4%) cases were venoarterial ECMO. This included 56 cases of extracorporeal cardiopulmonary resuscitation. Also, there were 30 (23.4%) cases of venovenous ECMO and 4 (3.1%) cases of venoarteriovenous ECMO. A total of 71 (55.5%) patients were cannulated under POCUS guidance, and 43 (33.6%) patients were cannulated under fluoroscopy guidance and 14 (10.9%) patients were cannulated by landmark guidance. No surgical cut downs were required. Misplacement of cannula occurred in 3 (2.3%) cases. All three occurred in the landmark-guided group. POCUS-guided cannulation is comparable to fluoroscopy-guided cannulation in terms of avoiding cannula misplacement. In our experience, POCUS-guided cannulation is a useful strategy over fluoroscopy- and landmark-guided cannulation during peripheral ECMO. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  12. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  13. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    Science.gov (United States)

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  14. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    Science.gov (United States)

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  15. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  16. Sphincter-saving extrasphincteric rectal dissection and proximal segmental sphincteric excision techniques by using combined abdominal and transvaginal anterior perineal access in female patients who have lower rectal cancer (Transvaginal low anterior rectal resection

    Directory of Open Access Journals (Sweden)

    Ali Naki Yücesoy

    2017-10-01

    Full Text Available Background: Combined abdominal and transvaginal anterior perineal approaches have been used as an alternative surgical method for the surgical treatment of the lower rectal cancer. The main aim of this paper is to describe the surgical stages of the combined abdominal and transvaginal approaches performed for lower rectal cancer, especially in transvaginal anterior perineal stage. Method: We have performed sphincter-saving surgical operations by using transvaginal anterior perineal access by combining with the abdominal access in four female patients who had lower rectal cancer. Results: Sphincter-saving extrasphincteric dissection and proximal segmental sphincteric excision techniques were performed in four female patients operated with combined abdominal and transvaginal anterior perineal approach. All patients were found to have continence. Postoperatively, one patient was converted to abdominoperineal rectal amputation due to the detected distal resection margin positivity. Conclusion: Transvaginal anterior perineal access provides the extrasphincteric rectal dissection possibility in the ischioanal fossa. Therefore, the combined abdominal and transvaginal anterior perineal approaches have been based on the different anatomical and surgical features when compared to intersphincteric dissection technique which is the most common used surgical procedure in lower rectal cancer surgery. Resumo: Introdução: Uma combinação de abordagens abdominal e perineal anterior transvaginal tem sido empregada como método cirúrgico alternativo para o tratamento cirúrgico do câncer de reto baixo. O principal objetivo do presente artigo é a descrição dos estágios cirúrgicos das abordagens abdominal e transvaginal combinadas realizadas para câncer de reto baixo, especialmente no estágio perineal anterior transvaginal. Método: Realizamos operações cirúrgicas com preservação de esfíncter com o uso do acesso perineal anterior transvaginal, em

  17. No. 351-Transvaginal Mesh Procedures for Pelvic Organ Prolapse.

    Science.gov (United States)

    Larouche, Maryse; Geoffrion, Roxana; Walter, Jens-Erik

    2017-11-01

    publications with study groups larger than 20 individuals were selected because this criterion was used in the largest meta-analysis referenced in this guideline. A total of 1470 studies were obtained; after selecting only applicable studies and excluding duplicates, 68 manuscripts were reviewed and included. The content and recommendations were drafted and agreed upon by the principal authors and members of the Urogynaecology Committee. The Board of the Society of Obstetricians and Gynaecologists of Canada approved the final draft for publication. The quality of evidence was rated using the criteria described in the Grading of Recommendations Assessment, Development and Evaluation methodology framework. The Summary of Findings is available upon request. It is expected that this guideline will benefit women with pelvic organ prolapse by ensuring that health care providers are aware of outcomes related to transvaginal mesh procedures and steps in the management of related complications. This should guide patient-informed consent before such procedures are undertaken. The benefits clearly outweigh the potential harms or costs of implementation of this guideline, although no direct harms or costs are identified. Evidence will be reviewed 5 years after publication to decide whether all or part of the guideline should be updated. However, if important new evidence is published prior to the 5-year cycle, the review process may be accelerated for a more rapid update of some recommendations. RECOMMENDATIONS. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  18. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    Science.gov (United States)

    2009-09-01

    ultrasound . J. Acoust. Soc.Am. 72 1926-1932, (1982) (7) Neppiras E A. Acoustic cavitation . Physics reports 61(3): 159-251, (1980) (8) ter Haar G R, Daniels...Guided Pulsed High-Intensity Focused Ultrasound Enhancement of 5b. GRANT NUMBER W81XWH-08-1-0469 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...failing to This work is aimed to study MR guided high intensity focused ultrasound (MRgHIFU) enhancement of gene therapy for Prostate Cancer. The

  19. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy

    DEFF Research Database (Denmark)

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B

    2015-01-01

    OBJECTIVE: To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. DESIGN: A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. SETTING: Hvidovre Univers...

  20. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Asociación entre variables hormonales y clínicas y el resultado del ultrasonido ginecológico en mujeres con síndrome metabólico. Association among hormonal and clinical variables and the result of the gynecological ultrasound in females with metabolic syndrome.

    Directory of Open Access Journals (Sweden)

    Gisel Ovies Carballo

    2008-08-01

    menstrual cycle, LH (3-5 days of the menstrual cycle, prolactin (3-5 days of the menstrual cycle, androgens (total testosterone, 3-5 days of the menstrual cycle, progesterone (21-23 days of the menstrual cycle were determined if they were menstruating; otherwise they were established at any moment. A transvaginal gynecological ultrasound in the early follicular phase was performed if they had menstruation, but if they were amenorrheic it was carried out at any time. A medical history was also made to explore obstetric history, menstrual formula, history of infertility and physical examination. Associations between the clinical and hormonal variables and the ultrasonographic result were investigated. RESULTS: 83.1 % of the anovulatory showed images suggestive of ovarian polycystosis. When the testosterone levels were associated with the ultrasound, in 80 % of those who had an elevated testosterone, the ultrasound showed images of ovarian polycystosis; however, when testosterone was normal, just 42.5 % had such images. Of the 39 patients with an index ³ 2, 32 (82.1 % presented an ultrasonographic image of ovarian polycystosis; however, when it was <2, only 49 % had them. 75 % of the females with infertility showed an ultrasound with signs of polycystic ovaries and 25 % did not. Of the 73 hirsute patients, 48 (65.8 % had a positive ultrasound for ovarian polycystosis, whereas 25 (34.2 % did not exhibit images suggestive of this disorder, without a significant difference. CONCLUSIONS: the association between anovulatory progesterone, elevated levels of testosterone, LH/FSH index ³ 2, infertility and hirsutism, with ultrasound images of polycystosis is very high in the studied women with metabolic syndrome.

  2. Magnetic resonance–guided interstitial high-intensity focused ultrasound for brain tumor ablation

    Science.gov (United States)

    MacDonell, Jacquelyn; Patel, Niravkumar; Rubino, Sebastian; Ghoshal, Goutam; Fischer, Gregory; Burdette, E. Clif; Hwang, Roy; Pilitsis, Julie G.

    2018-01-01

    Currently, treatment of brain tumors is limited to resection, chemotherapy, and radiotherapy. Thermal ablation has been recently explored. High-intensity focused ultrasound (HIFU) is being explored as an alternative. Specifically, the authors propose delivering HIFU internally to the tumor with an MRI-guided robotic assistant (MRgRA). The advantage of the authors’ interstitial device over external MRI-guided HIFU (MRgHIFU) is that it allows for conformal, precise ablation and concurrent tissue sampling. The authors describe their workflow for MRgRA HIFU delivery. PMID:29385926

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  4. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  5. The effect of dyad versus individual simulation-based ultrasound training on skills transfer

    DEFF Research Database (Denmark)

    Tolsgaard, Martin G; Madsen, Mette E; Oxlund, Birgitte S

    2015-01-01

    : This study was conducted to compare the effectiveness of simulation-based ultrasound training in pairs (dyad practice) with that of training alone (single-student practice) on skills transfer. METHODS: In a non-inferiority trial, 30 ultrasound novices were randomised to dyad (n = 16) or single-student (n...... through pre-, post- and transfer tests. The transfer test involved the assessment of a transvaginal ultrasound scan by one of two clinicians using the Objective Structured Assessment of Ultrasound Skills (OSAUS). RESULTS: Thirty participants completed the simulation-based training and 24...... interactions between training type and performance (p = 0.59). The dyad group demonstrated higher training efficiency in terms of simulator score per number of attempts compared with the single-student group (p = 0.03). CONCLUSION: Dyad practice improves the efficiency of simulation-based training and is non...

  6. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    Science.gov (United States)

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  7. Models to teach lung sonopathology and ultrasound-guided thoracentesis

    Directory of Open Access Journals (Sweden)

    Jacek A. Wojtczak

    2014-12-01

    Full Text Available Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand – eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter’s hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  8. Evaluation of Effectiveness of Embolization in Pelvic Congestion Syndrome with the New Vascular Occlusion Device (ArtVentive EOS™): Preliminary Results

    International Nuclear Information System (INIS)

    Pyra, Krzysztof; Woźniak, Sławomir; Drelich-Zbroja, Anna; Wolski, Andrzej; Jargiełło, Tomasz

    2016-01-01

    PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lack of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.

  9. Evaluation of Effectiveness of Embolization in Pelvic Congestion Syndrome with the New Vascular Occlusion Device (ArtVentive EOS™): Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Pyra, Krzysztof, E-mail: k.pyra@poczta.fm [Medical University of Lublin, Department of Interventional Radiology and Neuroradiology (Poland); Woźniak, Sławomir, E-mail: slavwo7572@gmail.com [Medical University of Lublin, III Gynecology Clinic (Poland); Drelich-Zbroja, Anna, E-mail: zbroanna@interia.pl; Wolski, Andrzej, E-mail: andrzej.s.wolski@gmail.com; Jargiełło, Tomasz, E-mail: tojarg@interia.pl [Medical University of Lublin, Department of Interventional Radiology and Neuroradiology (Poland)

    2016-08-15

    PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lack of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.

  10. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  11. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  12. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  13. Individualization of controlled ovarian stimulation in vitro fertilization using ovarian reserve markers.

    Science.gov (United States)

    Grisendi, Valentina; La Marca, Antonio

    2017-06-01

    In assisted reproduction technologies (ART) the controlled ovarian stimulation (COS) therapy is the starting point from which a good oocytes retrieval depends. Treatment individualization is based on ovarian response prediction, which largely depends on a woman's ovarian reserve. Anti-Müllerian hormone (AMH) and antral follicle count (AFC) are considered the most accurate and reliable markers of ovarian reserve. A literature search was carried out for studies that addressed the ability of AMH and AFC to predict poor and/or excessive ovarian response in IVF cycles. According to the predicted response to ovarian stimulation (poor- normal- or high-response) is today possible not only to personalize pre-treatment counseling with the couple, but also to individualize the ovarian stimulation protocol, choosing among GnRH-agonists or antagonists for endogenous follicle-stimulating hormone (FSH) suppression and formulating the FSH starting dose most adequate for the single patients. In this review we discuss how to choose the best COS therapy for the single patient, on the basis of the markers-guided ovarian response prediction.

  14. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  15. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, J., E-mail: jdavidson@doctors.org.u [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom); Jayaraman, S. [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom)

    2011-02-15

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  16. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  17. Update on the role of ultrasound guided radiofrequency ablation for thyroid nodule treatment

    DEFF Research Database (Denmark)

    Radzina, Maija; Cantisani, Vito; Rauda, Madara

    2017-01-01

    Thyroid nodules can be frequently detected in general population, most of them are benign, however malignant cases are rising in the past decades. Ultrasound (US) is the most common imaging modality to assess thyroid nodular lesions, plan patient work-up and guide minimally invasive treatment...

  18. Left-right differences in ovarian volume and antral follicle count in 1423 women of reproductive age

    DEFF Research Database (Denmark)

    Korsholm, Anne-Sofie; Hvidman, Helene Westring; Bentzen, Janne Gasseholm

    2017-01-01

    The aim of this cross-sectional study was to investigate side differences in antral follicle count (AFC) and ovarian volume in left versus right ovaries in relation to chronological and "biological" age, the latter estimated by anti-Müllerian hormone (AMH) levels. The cohort comprised 1423 women...... ≤ 0.003). AFC was significantly higher in the right compared to the left ovary in the three upper AMH quartiles (p ≤ 0.005). The findings were similar when stratified in age quartiles. More than half (54.8%) had polycystic ovarian (PCO) morphology in at least one ovary. Of these women, 46.3% (n = 361......: 1014 fertile and 409 infertile. All were examined by transvaginal sonography and serum AMH. Overall the right ovary contained 8.1% more antral follicles (p = 0.002) and had 10.7% larger volume compared with the left (p right ovarian volume was larger than the left (p...

  19. The Usefulness of Intensivist-Performed Bedside Drainage of Pleural Effusion via Ultrasound-Guided Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Joo Won Min

    2014-08-01

    CONCLUSIONS: Intensivist-performed bedside drainage of pleural effusion via ultrasound (US-guided pigtail catheter is useful and safe and may be recommended in some patients in an intensive care unit.

  20. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  1. Algorithm of Transvaginal Ultrasound and/or Hysterosalpingogram for Confirmation Testing at 3 Months after Essure Placement.

    Science.gov (United States)

    Vleugels, Michel; Cheng, Ru-Fong; Goldstein, Jeffrey; Bangerter, Keith; Connor, Viviane

    To evaluate the algorithm of transvaginal ultrasound (TVU) and/or modified hysterosalpingogram (HSG) confirmation testing 3 months after Essure placement to determine if women can rely on the device for permanent birth control. Interim analysis of an ongoing 10-year, prospective, multicenter, nonrandomized, single-arm, international trial (Canadian Task Force classification II-2). Twenty study centers in the United States (n = 12), Canada (n = 1), The Netherlands (n = 6), and Spain (n = 1). Women undergoing the Essure procedure for permanent birth control. Based on the algorithm for confirmation testing, women with an uncomplicated Essure procedure underwent TVU as the confirmation test; modified HSG was used for women ineligible for TVU, when TVU findings were abnormal or inconclusive, or based on the physician's discretion. Co-primary endpoints (intention-to-treat [ITT] population) were the reliance rate and the 1-year pregnancy rate. Safety evaluation was based on adverse events. Bilateral insert placement was attempted in 597 women (ITT population) and achieved in 582 of 597 (97.5%). A total of 547 women were told to rely on Essure for permanent birth control. Both co-primary endpoints met prespecified limits: based on Bayesian statistics, the reliance rate was 91.6% (547/597; 95% credible interval, 89.2%-93.6%) and the 1-year pregnancy rate .67% (95% credible interval, .16%-1.53%). Using the algorithm for confirmation testing, of 547 subjects told to rely on Essure, 470 (86%) underwent TVU alone, 30 (6%) had modified HSG alone, and 47 (9%) had TVU followed by modified HSG. Four women became pregnant after being told to rely on Essure. They all had confirmation testing with TVU alone, and each initially read incorrectly as optimal insert locations. In each case postpregnancy follow-up and root cause analysis revealed unsatisfactory insert locations, 2 of which were perforations. Most adverse events were mild and unrelated to Essure. The

  2. Ultrasound-guided transversus abdominis plane (TAP) block: a useful adjunct in the management of postoperative respiratory failure.

    Science.gov (United States)

    Singh, Mandeep; Chin, Ki Jinn; Chan, Vincent

    2011-06-01

    The ultrasound-guided transversus abdominis plane (TAP) block is a useful tool in controlling postoperative pain following abdominal surgery. The bilateral ultrasound-guided TAP blocks successfully managed the pain of a patient presenting with hypoxemia and respiratory failure in the Post-anesthesia Care Unit, following a laparotomy for small bowel obstruction during general anesthesia. The TAP block reduced systemic opioid requirements and opioid-induced sedation and respiratory depression, improved patient compliance with non-invasive positive pressure ventilation, and prevented the need for intubation and ventilation in the intensive care unit. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  4. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  5. Essure microinsert imaging: does abnormal shape on ultrasound predict complications on HSG?

    Science.gov (United States)

    VanBuren, Wendaline M; Suchet, Ian B; Thiel, John A; Karreman, Erwin

    2016-12-01

    We hypothesize that the shape of the Essure microinsert on ultrasound is able to predict complications evident on hysterosalpingogram (HSG), the accepted gold standard. From July 2, 2009 to July 2, 2012, 441 women at our institution received Essure microinsert placement for the purpose of permanent sterilization. 2D and 3D coronal plane transvaginal ultrasounds were performed three months after Essure microinsert placement. Those patients with complications identified on ultrasound, a non-diagnostic ultrasound, or following a difficult insertion were referred for HSG. Patients with both HSG and ultrasound performed were retrospectively selected and anonymized. The ultrasounds were reviewed by a single, blinded radiologist. A total of 122 microinserts in 65 patients were described on ultrasound using a numeric grading system and compared to HSG findings. Microinsert placement resulted in 37 complications, 31 of which were identified on ultrasound, including uterine and tubal perforations and placement in the endometrial cavity. The sensitivity of Essure microinsert shape on ultrasound in predicting complications, compared with standard HSG, was 94%, with a positive predictive value of 85%; specificity was 95%, with a negative predictive value of 98%. The Kappa coefficient was 0.85 (p Essure microinsert placement.

  6. Comparative study between ultrasound guided TAP block and paravertebral block in upper abdominal surgeries

    Directory of Open Access Journals (Sweden)

    Ruqaya M Elsayed Goda

    2017-01-01

    Conclusion: We concluded that ultrasound guided transverses abdominis plane block and thoracic paravertebral block were safe and effective anesthetic technique for upper abdominal surgery with longer and potent postoperative analgesia in thoracic paravertebral block than transverses abdominis block.

  7. Detection of the Single-Session Complete Ablation Rate by Contrast-Enhanced Ultrasound during Ultrasound-Guided Laser Ablation for Benign Thyroid Nodules: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Shuhua Ma

    2016-01-01

    Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.

  8. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  9. Efficacy of a single ultrasound-guided injection for the treatment of hip osteoarthritis.

    LENUS (Irish Health Repository)

    Atchia, Ismaël

    2011-01-01

    Intra-articular injection is effective for osteoarthritis, but the best single injection strategy is not known, nor are there established predictors of response. The objectives of this study were to assess and predict response to a single ultrasound-guided injection in moderate to severe hip osteoarthritis.

  10. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    Science.gov (United States)

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  11. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  12. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  13. Feasibility and safety of ultrasound-guided nerve block for management of limb injuries by emergency care physicians

    Directory of Open Access Journals (Sweden)

    Sanjeev Bhoi

    2012-01-01

    Full Text Available Background: Patients require procedural sedation and analgesia (PSA for the treatment of acute traumatic injuries. PSA has complications. Ultrasound (US guided peripheral nerve block is a safe alternative. Aim: Ultrasound guided nerve blocks for management of traumatic limb emergencies in Emergency Department (ED. Setting and Design: Prospective observational study conducted in ED. Materials and Methods: Patients above five years requiring analgesia for management of limb emergencies were recruited. Emergency Physicians trained in US guided nerve blocks performed the procedure. Statistical analysis: Effectiveness of pain control, using visual analogue scale was assessed at baseline and at 15 and 60 minutes after the procedure. Paired t test was used for comparison. Results: Fifty US guided nerve blocks were sciatic- 4 (8%, femoral-7 (14%, brachial- 29 (58%, median -6 (12%, and radial 2 (4% nerves. No patients required rescue PSA. Initial median VAS score was 9 (Inter Quartile Range [IQR] 7-10 and at 1 hour was 2(IQR 0-4. Median reduction in VAS score was 7.44 (IQR 8-10(75%, 1-2(25% (P=0.0001. Median procedure time was 9 minutes (IQR 3, 12 minutes and median time to reduction of pain was 5 minutes (IQR 1,15 minutes. No immediate or late complications noticed at 3 months. Conclusion: Ultrasound-guided nerve blocks can be safely and effectively performed for upper and lower limb emergencies by emergency physicians with adequate training.

  14. Ultrasound-guided epidural anesthesia for a parturient with severe malformations of the skeletal system undergoing cesarean delivery: a case report

    Directory of Open Access Journals (Sweden)

    Luo LL

    2015-05-01

    Full Text Available LinLi Luo,* Juan Ni,* Lan Wu, Dong Luo Department of Anesthesiology, West China Second Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China  *These authors contributed equally to this work and should be considered co-first authors Abstract: Anesthetic management of patients with preexisting diseases is challenging and individualized approaches need to be determined based on patients' complications. We report here a case of ultrasound-guided epidural anesthesia in combination with low-dose ketamine during cesarean delivery on a parturient with severe malformations of the skeletal system and airway problems. The ultrasound-guided epidural anesthesia was performed in the L1–L2 space, followed by an intravenous administration of ketamine (0.5 mg/kg for sedation and analgesia. Satisfactory anesthesia was provided to the patient and spontaneous ventilation was maintained during the surgery. The mother and the baby were discharged 5 days after surgery, no complications were reported for either of them. Our work demonstrated that an ultrasound-guided epidural anesthesia combined with low-dose ketamine can be used to successfully maintain spontaneous ventilation and provide effective analgesia during surgery and reduce the risk of postoperative anesthesia-related pulmonary infection. Keywords: anesthesia, regional, cesarean delivery, ketamine, ultrasound-guided

  15. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion

    NARCIS (Netherlands)

    Venderink, W.; Govers, T.M.; Rooij, M. de; Futterer, J.J.; Sedelaar, J.P.M.

    2017-01-01

    OBJECTIVE: Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. MATERIALS AND METHODS: A decision tree and Markov model were

  16. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  17. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  18. Risk of malignancy index in the preoperative evaluation of patients with ovarian masses

    International Nuclear Information System (INIS)

    Jabeen, R.; Khan, S.A.; Naveed, S.

    2015-01-01

    Objective: To evaluate the ability of RMI in preoperative discrimination of benign from malignant ovarian mass among women presenting at Nishtar Hospital Multan Pakistan. Methodology: It was a prospective study conducted at department of obstetrics/gynae Nishtar Hospital Multan between September 2008 to August 2009. 60 patients of more than 30 years of age admitted in gynaecology department for surgical exploration of ovarian mass were included. All the women in whom ovarian malignancy had already been diagnosed and admitted for second laparotomy were excluded. Results: The median age at presentation of ovarian malignancy is 56 years. The sensitivity of RMI in our group was 82.3%,the specificity was 88.3%, positive predictive value was 73.7% and the negative predictive value was 92.6%. Receiver operating curves reveal that RMI was a better diagnostic marker than CA-125 or ultrasound score alone for the prediction of malignancy in ovarian masses. Conclusion: The risk of malignancy index has high specificity and sensitivity. It yielded a better diagnostic performance as compared to CA-125 or ultrasound score alone in differentiating benign from malignant ovarian lesions. (author)

  19. Ovarian cancer screening and mortality in the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS): a randomised controlled trial

    Science.gov (United States)

    Jacobs, Ian J; Menon, Usha; Ryan, Andy; Gentry-Maharaj, Aleksandra; Burnell, Matthew; Kalsi, Jatinderpal K; Amso, Nazar N; Apostolidou, Sophia; Benjamin, Elizabeth; Cruickshank, Derek; Crump, Danielle N; Davies, Susan K; Dawnay, Anne; Dobbs, Stephen; Fletcher, Gwendolen; Ford, Jeremy; Godfrey, Keith; Gunu, Richard; Habib, Mariam; Hallett, Rachel; Herod, Jonathan; Jenkins, Howard; Karpinskyj, Chloe; Leeson, Simon; Lewis, Sara J; Liston, William R; Lopes, Alberto; Mould, Tim; Murdoch, John; Oram, David; Rabideau, Dustin J; Reynolds, Karina; Scott, Ian; Seif, Mourad W; Sharma, Aarti; Singh, Naveena; Taylor, Julie; Warburton, Fiona; Widschwendter, Martin; Williamson, Karin; Woolas, Robert; Fallowfield, Lesley; McGuire, Alistair J; Campbell, Stuart; Parmar, Mahesh; Skates, Steven J

    2016-01-01

    Summary Background Ovarian cancer has a poor prognosis, with just 40% of patients surviving 5 years. We designed this trial to establish the effect of early detection by screening on ovarian cancer mortality. Methods In this randomised controlled trial, we recruited postmenopausal women aged 50–74 years from 13 centres in National Health Service Trusts in England, Wales, and Northern Ireland. Exclusion criteria were previous bilateral oophorectomy or ovarian malignancy, increased risk of familial ovarian cancer, and active non-ovarian malignancy. The trial management system confirmed eligibility and randomly allocated participants in blocks of 32 using computer-generated random numbers to annual multimodal screening (MMS) with serum CA125 interpreted with use of the risk of ovarian cancer algorithm, annual transvaginal ultrasound screening (USS), or no screening, in a 1:1:2 ratio. The primary outcome was death due to ovarian cancer by Dec 31, 2014, comparing MMS and USS separately with no screening, ascertained by an outcomes committee masked to randomisation group. All analyses were by modified intention to screen, excluding the small number of women we discovered after randomisation to have a bilateral oophorectomy, have ovarian cancer, or had exited the registry before recruitment. Investigators and participants were aware of screening type. This trial is registered with ClinicalTrials.gov, number NCT00058032. Findings Between June 1, 2001, and Oct 21, 2005, we randomly allocated 202 638 women: 50 640 (25·0%) to MMS, 50 639 (25·0%) to USS, and 101 359 (50·0%) to no screening. 202 546 (>99·9%) women were eligible for analysis: 50 624 (>99·9%) women in the MMS group, 50 623 (>99·9%) in the USS group, and 101 299 (>99·9%) in the no screening group. Screening ended on Dec 31, 2011, and included 345 570 MMS and 327 775 USS annual screening episodes. At a median follow-up of 11·1 years (IQR 10·0–12·0), we diagnosed ovarian cancer in

  20. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Complications of transvaginal silicone-coated polyester synthetic mesh sling.

    Science.gov (United States)

    Govier, F E; Kobashi, K C; Kuznetsov, D D; Comiter, C; Jones, P; Dakil, S E; James, R

    2005-10-01

    To report a premarket multicenter trial to test the feasibility of a transvaginal silicone-coated polyester synthetic mesh sling in women with anatomic incontinence. Fifty-one patients in four centers underwent transvaginal placement of a silicone-coated polyester synthetic mesh sling (American Medical Systems) during an 8-month period. Of the 51 patients, 31 were part of a prospective institutional review board-approved feasibility trial in three centers funded by American Medical Systems (group 1) and 20 underwent implantation by a single surgeon and their data were retrospectively reviewed (group 2). The studies were done concomitantly, and all slings were fixed transvaginally with bone anchors. All patients in group 1 were followed up at 4 weeks, 6 months, and 1 year (as applicable) with repeat questionnaires, physical examinations, and pad tests. In group 1, 20 patients completed 6 months of follow-up. Ten patients (32%) required a second surgical procedure at an average of 183 days (range 68 to 343) postoperatively. Eight patients (26%) had vaginal extrusion of the mesh, one (3%) required sling lysis, and one (3%) required sling removal because of infection. In group 2, 8 patients (40%) underwent sling removal for vaginal extrusion at a mean of 160 days (range 83 to 214). Transvaginally placed silicone-coated mesh slings used for the treatment of urinary incontinence demonstrated an unacceptably high vaginal extrusion rate in this study. Once identified, this study was immediately terminated, and this product was not marketed for this application in the United States.

  2. A Case of Bilateral Acute Calcific Tendinitis of the Gluteus Medius, Treated by Ultrasound-guided Needle Lavage and Corticosteroid Injection

    OpenAIRE

    Vereecke, Elke; Mermuys, Koen; Casselman, Jan

    2015-01-01

    Calcium hydroxyapatite deposition disease is a common pathology, most frequently located in the rotator cuff tendons of the shoulder, for which different therapeutic approaches are used. Ultrasound guided needle lavage and injection of anesthetic/corticosteroid is a well-known and extensively described treatment for calcific tendinits of the rotator cuff. We present a case of bilateral calcific tendinitis of the gluteus medius tendon, both sides successfully treated using ultrasound guided ne...

  3. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    International Nuclear Information System (INIS)

    Spiliopoulos, S.; Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D.

    2011-01-01

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 ± 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 ± 1.6 versus 4.6 ± 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 ± 2.7 versus 19 ± 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 ± 1.3 versus 4.5 ± 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  4. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    Energy Technology Data Exchange (ETDEWEB)

    Spiliopoulos, S., E-mail: stavspiliop@upatras.g [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece); Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D. [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece)

    2011-05-15

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 {+-} 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 {+-} 1.6 versus 4.6 {+-} 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 {+-} 2.7 versus 19 {+-} 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 {+-} 1.3 versus 4.5 {+-} 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  5. Ultrasound guided percutaneous treatment and follow-up of Baker's cyst in knee osteoarthritis

    International Nuclear Information System (INIS)

    Köroğlu, Mert; Çallıoğlu, Mehmet; Eriş, Hüseyin Naim; Kayan, Mustafa; Çetin, Meltem; Yener, Mahmut; Gürses, Cemil; Erol, Bekir; Türkbey, Barış; Parlak, Ayşe Eda; Akhan, Okan

    2012-01-01

    Objective: Purpose of this study is to assess sonographic changes and clinical response in different subgroups of Baker's cyst patients with knee osteoarthritis after a single session of ultrasound-guided percutaneous aspiration and corticosteroid injection. Materials and methods: Thirty-two knee osteoarthritis patients (46–85 years, mean 58.97 ± 9.88) with symptomatic Baker's cyst diagnosed at ultrasonography were included in the study. To determine the grade of the symptoms, Visual Analogue Scale was applied. The patients were grouped in two, as simple (n = 24) and complex (n = 8) Baker's cyst. Thirty-two ultrasound-guided cyst aspirations concomitant 1 ml betamethasone injection (24 simple, 8 complex subgroups) were performed. Patients were followed clinically as well as via ultrasonography for 6 months after procedures. Results: A significant decrease in volume of the Baker's cysts after percutaneous treatment was accompanied by a significant clinical improvement. Moreover, the volume reduction of Baker's cyst after the treatment was significantly correlated with the clinical improvement (Pearson correlation coefficient = 0.542, p = 0.001). All 6 Baker's cysts relapsed at ultrasonography were complex type. Furthermore, a comparison of patients with simple Baker's cysts and those with complex Baker's cysts demonstrated no significant change in Visual Analogue Scale scores between two groups (p = 0.061, Mann–Whitney U). No complications (minor or major) occurred secondary to percutaneous treatment. Conclusion: Baker's cysts can be grouped as simple and complex groups via ultrasonography prior to the treatment. Cyst aspiration with ultrasound-guided corticosteroid injection yields clinical improvement and cyst volume reduction in all subgroups of patients with Baker's cyst secondary to knee osteoarthritis.

  6. Ovarian cystic teratoma containing balls of fat. A case report

    International Nuclear Information System (INIS)

    Salinas, A.; Rebolledo, M.; Escribano, M.; Alejo, J. P.; Morenom, J.

    1998-01-01

    We present the case of a ovarian cystic teratoma characterized predominantly by the mobile balls floating in the intra cystic fluid. Ultrasonography demonstrated their marked echo reflectivity and computed tomography revealed that they had the density of fat. We establish a relationship among the ultrasound, computed tomography and histological findings in this uncommon type of ovarian cystic teratoma. (Author) 6 refs

  7. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  8. Poor man's NOTES: can it be a good approach for adhesiolysis? A first case report with video demonstration.

    Science.gov (United States)

    Baekelandt, Jan

    2015-01-01

    To show that in selected cases transvaginal NOTES can be a frugally innovative approach for adhesiolysis and that it can be performed in a low-cost setting. Step-by-step explanation of the technique using videos and pictures (educative video). A 51-year old (para 2, gravida 2) presented with meso- and hypogastric pain. Two years before, an umbilical hernia had been repaired using a Proceed Ventral Patch mesh. The diagnosis of pain caused by adhesions was made, and laparoscopic adhesiolysis was planned. On ultrasound, a small left ovarian fibroma was visualized. Because of the suspected umbilical location of the adhesions, we decided to use a transvaginal NOTES approach to perform adhesiolysis and left adnexectomy. Pathological examination confirmed a small benign papillary serous adenofibroma of the ovary. A transvaginal NOTES approach to perform adhesiolysis combined with left adnexectomy using only standard reusable laparoscopic instruments and a low-cost self-constructed NOTES port. The procedure and postoperative recovery were uneventful. No minor or major complications occurred. The patient has been cured of her pain. Transvaginal NOTES is a novel approach that requires further validation. This case report shows that transvaginal NOTES can be used to perform adhesiolysis for abdominal pain and that it can be performed in a low-cost setting without the need for expensive ports or disposable instruments. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Effects of using simulation versus CD-ROM in the performance of ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Gasko, John; Johnson, Arthur; Sherner, John; Craig, John; Gegel, Brian; Burgert, James; Sama, Samuel; Franzen, Thomas

    2012-08-01

    The purpose of this study was to determine which method of teaching, CD-ROM, simulation, or a combination of both, was more effective in increasing the performance of ultrasound-guided regional anesthesia. No studies have investigated these methods. The framework for this study was critical thinking. The study was a prospective, mixed (between and within) subjects, experimental design. The sample consisted of 29 student registered nurse anesthetists randomly assigned to 1 of 3 groups: CD-ROM (n = 11), simulation (n = 11), and combination (n = 7). All groups were evaluated by the use of cadavers before and 2 months after the intervention using a valid and reliable instrument of performance. A repeated-measures analysis of variance indicated that the combination was significantly better than the CD-ROM and simulation (P teaching ultrasound-guided regional anesthesia techniques.

  10. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    Energy Technology Data Exchange (ETDEWEB)

    García-Medina, J., E-mail: josegmedina57@gmail.com [“Reina Sofia” University Hospital, Vascular and Interventional Radiology Unit, Department of Radiology (Spain); García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com [University of Murcia, Faculty of Medicine (Spain)

    2017-05-15

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

  11. Alleviating Pancreatic Cancer-Associated Pain Using Endoscopic Ultrasound-Guided Neurolysis

    Science.gov (United States)

    Takenaka, Mamoru; Kamata, Ken; Yoshikawa, Tomoe; Nakai, Atsushi; Omoto, Shunsuke; Miyata, Takeshi; Yamao, Kentaro; Imai, Hajime; Sakamoto, Hiroki; Kitano, Masayuki; Kudo, Masatoshi

    2018-01-01

    The most common symptom in patients with advanced pancreatic cancer is abdominal pain. This has traditionally been treated with nonsteroidal anti-inflammatory drugs and opioid analgesics. However, these treatments result in inadequate pain control or drug-related adverse effects in some patients. An alternative pain-relief modality is celiac plexus neurolysis, in which the celiac plexus is chemically ablated. This procedure was performed percutaneously or intraoperatively until 1996, when endoscopic ultrasound (EUS)-guided celiac plexus neurolysis was first described. In this transgastric anterior approach, a neurolytic agent is injected around the celiac trunk under EUS guidance. The procedure gained popularity as a minimally invasive approach and is currently widely used to treat pancreatic cancer-associated pain. We focus on two relatively new techniques of EUS-guided neurolysis: EUS-guided celiac ganglia neurolysis and EUS-guided broad plexus neurolysis, which have been developed to improve efficacy. Although the techniques are safe and effective in general, some serious adverse events including ischemic and infectious complications have been reported as the procedure has gained widespread popularity. We summarize reported clinical outcomes of EUS-guided neurolysis in pancreatic cancer (from the PubMed and Embase databases) with a goal of providing information useful in developing strategies for pancreatic cancer-associated pain alleviation. PMID:29462851

  12. Endoscopic ultrasound-guided hepaticogastrostomy for advanced cholangiocarcinoma after failed stenting by endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Sukij Panpimanmas

    2013-10-01

    Conclusion: Endoscopic-ultrasound-guided hepaticogastrostomy is safe and can be a good palliative option for advanced malignant biliary obstruction because it drains internally and is remote from the tumor site, promoting a long patency period of prosthesis and better quality of life.

  13. Ultrasound-guided lateral infraclavicular block evaluated by infrared thermography and distal skin temperature

    DEFF Research Database (Denmark)

    Asghar, Semera; Lundstrøm, Lars Hyldborg; Bjerregaard, Lars Stryhn

    2014-01-01

    of the 2nd and 5th digits. METHODS: We performed an ultrasound-guided lateral infraclavicular block in 45 patients undergoing upper limb surgery. The contralateral hand served as control and we obtained infrared thermographic images of both hands before the block and during the following 30 min. We defined...

  14. [Current state of transvaginal meshes by resolution of pelvic organ prolapse].

    Science.gov (United States)

    Jírová, J; Pán, M

    Treatment of pelvic organs prolapse with transvaginal mesh kits represents nowadays a widespread surgical method, which partially replaced classic operations due to high success rate and low count of recurrences. Just like any other surgical method, the placement of transvaginal mesh is linked with occurrence of complications. In this article we attempt to review the more and less known facts about trans-vaginal meshes, their efficacy, count of recurrence and the spectrum of complications and we try to compare this technique with traditional surgical methods used to treat pelvic organs prolapse (without graft materials). Review. Department of Obstetrics and Gynecology, Regional hospital Mladá Boleslav a.s., Mladá Boleslav. Overview of the results of recent studies published in the Czech and English language in recent years. Pelvic organ prolapse repair with vaginal mesh has generally lower count of relapse especially in patients with wide genital hiatal area and with major levator ani avulsion. The spectrum of complications differs from classical techniques because of the presence of synthetic nonabsorbable material. Some of the specific complications we did not encounter during classical operations include vaginal mesh erosion, infection of mesh associated with chronic pelvic pain, dyspareunia, protrusion of the mesh into the closest organs or the rejection and progressive extrusion of the mesh. Primary enthusiasm has now been replaced with worries of major complications. Future tasks should therefore be aimed at minimizing the rate of complications associated with transvaginal meshes. Except using well-known and safe materials and providing specialized training of physicians for each mesh implantation technique, other precautions outlined in this article should help, such as a closer specification of indication for the application of transvaginal mesh.

  15. Randomized trial of tourniquet vs blood pressure cuff for target vein dilation in ultrasound-guided peripheral intravenous access.

    Science.gov (United States)

    Nelson, Drew; Jeanmonod, Rebecca; Jeanmonod, Donald

    2014-07-01

    Ten percent of the time, peripheral intravenous access (PIV) is not obtained in 2 attempts in the emergency department. Typically, a tourniquet is used to dilate the target vein; but recent research showed that a blood pressure (BP) cuff improves dilation, which may translate to increased PIV success. We sought to determine if there is improved success in obtaining ultrasound-guided PIV using a BP cuff vs a tourniquet in "difficult stick" patients. This is a prospective, randomized, single-blinded trial. Adult patients requiring PIV with at least 2 prior failed attempts were enrolled. Patients were assigned to tourniquet or BP cuff for target vein dilation randomly. Nurses prepared the patient for PIV attempt by either placing a BP cuff inflated to 150 mm Hg or placing a tourniquet on the chosen extremity. The extremity was draped to blind the physician to assignment. Physicians then attempted ultrasound-guided PIV. Failures were defined as IVs requiring greater than 3 ultrasound-guided attempts or 30 minutes, or patient intolerance. If failure occurred, the physician was unblinded; and the patient could be crossed over and reattempted. Thirty-eight patients were enrolled. The success rate for the tourniquet group (n = 17) and BP cuff group (n = 21) was 82.4% and 47.6%, respectively (P = .04). There were no differences between groups for vessel depth, diameter, or procedure time. Six in the BP cuff group were crossed over and had successful PIV obtained with tourniquet. Tourniquet is superior to BP cuff for target vein dilation in ultrasound-guided PIV. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  17. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  18. Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-01-01

    Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 - 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice.

  19. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  20. Ultrasound-guided block of the axillary nerve

    DEFF Research Database (Denmark)

    Rothe, C; Lund, J; Jenstrup, M T

    2012-01-01

    The specific blocking of the axillary nerve has never been investigated clinically. We present four cases illustrating potential applications of the axillary nerve block in the perioperative setting and discuss possible directions for future research in this area. The axillary nerve blocks were all...... performed using a newly developed in-plane ultrasound-guided technique. In one patient undergoing arthroscopic shoulder surgery, we used the axillary nerve block as the only analgesic combined with propofol sedation and spontaneous breathing. Chronic shoulder pain was eliminated after the axillary nerve...... block in two patients. The pain score after arthroscopic shoulder surgery in these two patients remained low until termination of the nerve block. In a fourth patient, severe post-operative pain after osteosynthesis of a displaced proximal humerus fracture was almost eliminated after performing...

  1. Assessment of ovarian reserve in euthyroid adolescents with Hashimoto thyroiditis.

    Science.gov (United States)

    Pirgon, Ozgur; Sivrice, Cigdem; Demirtas, Hakan; Dundar, Bumin

    2016-01-01

    We aimed to investigate the ovarian function and reserve in euthyroid adolescents (TSH Hashimoto thyroiditis (HT). This case-control study included 30 adolescent girls (mean age 15.1 ± 1.4 years) newly diagnosed as HT with presence of high thyroid antibodies with gland heterogeneity in ultrasound and age-matched 30 healthy female subjects. Anti-ovarian antibody (AOAb), LH/FSH ratio, estradiol, anti-mullerian hormone (AMH), inhibin-B, total testosterone, antral follicle count, ovarian volumes and uterine length were measured. The clinical, laboratory, and ultrasound data of the HT and control groups were compared. There were no significant differences between the girls with HT and healthy controls in relation to LH/FSH ratio, estradiol and inhibin-B levels. AOAb (p = 0.02), AMH (p = 0.007) and total testosterone levels were higher in HT group than the control group (p = 0.03). AOAb level was found to be positively correlated with LH/FSH ratio (p = 0.03), AMH (p = 0.01) and inhibin-B (p thyroiditis had normal ovarian reserve based on measurements of AMH, inhibin B, FSH, LH/FSH ratio, estradiol and antral follicle counts.

  2. Imaging features of ovarian metastases from colonic adenocarcinoma in adolescents

    International Nuclear Information System (INIS)

    Kauffman, W.M.; Jenkins, J.J. III; Helton, K.; Rao, B.N.; Winer-Muram, H.T.; Pratt, C.B.

    1995-01-01

    This paper describes the imaging features of ovarian metastases from adenocarcinoma of the colon in adolescent females. We reviewed retrospectively abdominal and pelvic computed tomographic and pelvic ultrasound examinations, histologic slices, and clinical charts of six adolescent females with ovarian metastases secondary to adenocarcinoma of the colon. One patient had ovarian metastasis at presentation and was presumed to have a primary ovarian tumor. The ovarian metastases were either solid (n = 3), complex with both solid and cystic components (n = 2), or multilocular cysts (n = 1). The ovarian lesions were large, ranging from 6 cm to 18 cm in diameter. Colorectal carcinoma in adolescent females is frequently associated with ovarian metastases. One imaging characteristic differs in adult and adolescent ovarian metastases, although they do have features in common: in adolescents, a smaller proportion of colorectal ovarian metastases are multicystic (17%) compared with the adult series (45%). These lesions are frequently large and may be complex, multicystic, or solid. Although it is a rare disease, the differential dignosis of adnexal masses in adolescent females should include ovarian metastases from adenocarcinoma of the colon. (orig.)

  3. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  4. Thrombosis of right ovarian vein

    International Nuclear Information System (INIS)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M.

    2001-01-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs

  5. Is the stripping technique a tissue-sparing procedure in large simple ovarian cysts in children?

    Science.gov (United States)

    Arena, Francesco; Romeo, Carmelo; Castagnetti, Marco; Scalfari, GianFranco; Cimador, Marcello; Impellizzeri, Pietro; Villari, Daniela; Zimbaro, Fabrizio; DeGrazia, Enrico

    2008-07-01

    Stripping of the cystic wall is performed by gynecologists to treat large ovarian cysts. Information in the pediatric population is poor. We prospectively evaluated the pathologic specimens of large ovarian cyst to determine whether the stripping technique is a tissue-sparing procedure even in this age. We evaluated 5 patients. Samples were taken from the intermediate part of the cystic wall and from the layer covering the cyst during excision. The presence of ovarian tissue adjacent to the cyst wall, and the morphological features of the surrounding tissue were both evaluated. Pelvic ultrasound follow-up was also performed. Patients' mean age was 4.5 years (7 days to 12 years). All cysts were removed because all were symptomatic. The mean diameter was 86.6 mm (74-100 mm). Cysts were follicular in 2 cases, serous in other two, and endometriotic in 1 case. Adjacent ovarian tissue was present in 1 of 5 specimens and was approximately 1 to 2 mm in thickness. The layer adjacent to the cystic wall always appeared as normal ovarian tissue. Ultrasound scans at follow-up revealed presence of ovarian tissue. The stripping procedure for large ovarian cyst excision allows to spare the adjacent normal ovarian tissue even in pediatric age because ovarian tissue is rarely excised with the cyst wall during the procedure.

  6. Cesarean Delivery Changes the Natural Position of the Uterus on Transvaginal Ultrasonography.

    Science.gov (United States)

    Kaelin Agten, Andrea; Honart, Anne; Monteagudo, Ana; McClelland, Spencer; Basher, Basmy; Timor-Tritsch, Ilan E

    2018-05-01

    To assess whether cesarean delivery changes the natural position of the uterus. In this retrospective Institutional Review Board-approved cohort study, we conducted a search of our university gynecologic ultrasonography (US) database. Patients with transvaginal US images before and after either vaginal or cesarean delivery between 2012 and 2015 were included. Women with prior cesarean delivery were excluded. Two readers independently measured antepartum and postpartum flexion angles between the longitudinal axis of the uterine body and the cervix. We calculated intraclass correlation coefficients to measure inter-reader agreement. Antepartum and postpartum uterine flexion angles were compared between patients with vaginal and cesarean delivery. We included 173 patients (107 vaginal and 66 cesarean delivery). The mean interval between scans ± SD was 18 ± 10 months. Inter-reader agreement for flexion angles was almost perfect (intraclass correlation coefficients: antepartum, 0.939; postpartum, 0.969; both P cesarean delivery (154.8° ± 45.7°) versus vaginal delivery (145.8° ± 43.7°; P = .216). Mean postpartum flexion angles were higher after cesarean delivery (180.4° ± 51.2°) versus vaginal delivery (152.8° ± 47.7°; P = .001. Differences in antepartum and postpartum flexion angles between cesarean and vaginal delivery were statistically significant (25.6° versus 7.0°; P = .027). Cesarean delivery can change the uterine flexion angle to a more retroflexed position. Therefore, all women with a history of cesarean delivery should undergo a transvaginal US examination before any gynecologic surgery or intrauterine device placement to reduce the possibility of surgical complications. © 2017 by the American Institute of Ultrasound in Medicine.

  7. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  8. Longitudinal transvaginal ultrasound evaluation of cesarean scar niche incidence and depth in the first two years after single- or double-layer uterotomy closure: a randomized controlled trial.

    Science.gov (United States)

    Bamberg, Christian; Hinkson, Larry; Dudenhausen, Joachim W; Bujak, Verena; Kalache, Karim D; Henrich, Wolfgang

    2017-12-01

    Cesarean deliveries are the most common abdominal surgery procedure globally, and the optimal way to suture the hysterotomy remains a matter of debate. The aim of this study was to assess the incidence of cesarean scar niches and the depth after single- or double-layer uterine closure. We performed a randomized controlled trial in which women were allocated to three uterotomy suture techniques: continuous single-layer unlocked, continuous locked single-layer, or double-layer sutures. Transvaginal ultrasound was performed six weeks and 6-24 months after cesarean delivery [Clinicaltrials.gov (NCT02338388)]. The study included 435 women. Six weeks after delivery, the incidence of niche was not significantly different between the groups (p = 0.52): 40% for single-layer unlocked, 32% for single-layer locked and 43% for double-layer sutures. The mean ± SD niche depths were 3.0 ± 1.4 mm for single-layer unlocked, 3.6 ± 1.7 mm for single-layer locked and 3.3 ± 1.3 mm for double-layer sutures (p = 1.0). There were no significant differences (p = 0.58) in niche incidence between the three groups at the second ultrasound follow up: 30% for single-layer unlocked, 23% for single-layer locked and 29% for double-layer sutures. The mean ± SD niche depth was 3.1 ± 1.5 mm after single-layer unlocked, 2.8 ± 1.5 mm after single-layer locked and 2.5 ± 1.2 mm after double-layer sutures (p = 0.61). There was a trend (p = 0.06) for the residual myometrium thickness to be thicker after double-layer repair at the long-term follow up. The incidence of cesarean scar niche formation and the niche depth was independent of the hysterotomy closure technique. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  9. Preoperative diagnosis of fallopian tube malignancy with transvaginal color doppler ultrasonography and magnetic resonance imaging after negative hysteroscopy for postmenopausal bleeding.

    Science.gov (United States)

    Arko, Darja; Žegura, Branka; Virag, Mirjana; Fokter Dovnik, Nina; Takač, Iztok

    2014-09-01

    Primary fallopian tube carcinoma is a rare malignancy and is not often diagnosed preoperatively. We present a case of a 67-year-old woman who complained of postmenopausal vaginal bleeding. After a negative hysteroscopy, transvaginal ultrasound showed a well vascularized solid-cystic tumor in the adnexal region separate from the ovary. The presence of an adnexal mass was confirmed by MR imaging. Total abdominal hysterectomy with bilateral salpingoophorectomy, omentectomy and appendectomy, as well as pelvic and paraaortic lymphadenectomy was performed. The pathohistological diagnosis was poorly differentiated serous adenocarcinoma of the fallopian tube, FIGO stage IA. The patient was subsequently treated with platinum based adjuvant chemotherapy.

  10. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    Science.gov (United States)

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  11. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    Science.gov (United States)

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  12. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    Science.gov (United States)

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  13. Efficacy of ultrasound-guided transversus abdominis plane block for postoperative analgesia in patients undergoing inguinal hernia repair

    Directory of Open Access Journals (Sweden)

    Venkatraman R

    2016-01-01

    Full Text Available Rajagopalan Venkatraman, Ranganathan Jothi Abhinaya, Ayyanar Sakthivel, Govindarajan Sivarajan Department of Anaesthesia, SRM Medical College Hospital and Research Centre, Chennai, Tamil Nadu, India Background and aim: Transversus abdominis plane block (TAP block is a novel procedure to provide postoperative analgesia following inguinal hernia surgery. The utilization of ultrasound has greatly augmented the success rate of this block and additionally avoiding complications. The aim of our study was to gauge the analgesic efficacy of ultrasound-guided TAP block in patients undergoing unilateral inguinal hernia repair. Materials and methods: Sixty patients scheduled for elective inguinal hernia repair were selected for the study. At the end of the surgical procedure, they were randomly divided into two groups. Ultrasound-guided TAP block was performed with 20 mL of ropivacaine 0.2% (group A or normal saline (group B. Visual analog scale (VAS scores were used to assess pain. Paracetamol was given if VAS >3 and tramadol was used when VAS >6. Patients were monitored for VAS scores and total analgesic consumption for the 24-hour period. Results: The TAP block with ropivacaine (group A reduced VAS scores at 4, 6, and 12 hours. There was no distinction in VAS scores at 0, 2, and 24 hours between the two groups. The duration of analgesia for TAP block with ropivacaine lasted for 390 minutes. Total analgesics consumption was also significantly reduced in group A than group B. No complication was reported to TAP block in both the groups. Conclusion: The ultrasound-guided TAP block provides good postoperative analgesia, reduces analgesic requirements, and provides good VAS scores with fewer complications following inguinal hernia surgery. Keywords: inguinal hernia repair, postoperative analgesia, ropivacaine, transversus abdominis block, ultrasound

  14. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  15. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    Directory of Open Access Journals (Sweden)

    Enrico Pierluigi Spugnini

    2017-03-01

    Full Text Available A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR. Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors.

  16. WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.

  17. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Ae Rang [Dept. of Diagnostic Radiology, St. Carollo General Hospital, Suncheon (Korea, Republic of); Sohn, Seok Joon [Dept. of Preventive Medicine, Chonnam National University Medical School, Chonnam National University Hospital, Gwangju (Korea, Republic of); Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-06-15

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic.

  18. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    International Nuclear Information System (INIS)

    Woo, Ae Rang; Sohn, Seok Joon; Moon, Il Bong; Dong, Kyung Rae

    2017-01-01

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic

  19. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  20. Histopathology of breast cancer after magnetic resonance-guided high-intensity focused ultrasound and radiofrequency ablation

    NARCIS (Netherlands)

    Knuttel, Floor; Waaijer, Laurien; Merckel, LG; van den Bosch, Maurice A A J; Witkamp, Arjen J.; Deckers, Roel; van Diest, Paul J.

    AIMS: Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation and radiofrequency ablation (RFA) are being researched as possible substitutes for surgery in breast cancer patients. The histopathological appearance of ablated tissue has not been studied in great detail. This

  1. ultrasound-guided shoulder arthrogram injection

    African Journals Online (AJOL)

    2008-10-15

    Oct 15, 2008 ... Using an aseptic technique and without moving the ultrasound transducer from the desired transverse plane, the needle is advanced into the joint space through the rotator cuff interval, using real-time ultrasound guidance (Fig.2). The needle is inserted into the shoulder approximately midway between the ...

  2. Distal infrared thermography and skin temperature after ultrasound-guided interscalene brachial plexus block

    DEFF Research Database (Denmark)

    Asghar, Semera; Bjerregaard, Lars S; Lundstrøm, Lars H

    2014-01-01

    thermographic imaging of the hand before and at 1 min intervals for 30 min after an ultrasound-guided IBPB with 20 ml ropivacaine 7.5 mg ml. Cooling of both hands was performed to standardise measurements. MAIN OUTCOME MEASURES: Thermographic changes in skin temperature on the dorsum of the hand. RESULTS: Forty...

  3. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  4. Ultrasound guided injection of dexamethasone versus placebo for treatment of plantar fasciitis: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Gilheany Mark F

    2010-07-01

    Full Text Available Abstract Background Plantar fasciitis is the most commonly reported cause of chronic pain beneath the heel. Management of this condition commonly involves the use of corticosteroid injection in cases where less invasive treatments have failed. However, despite widespread use, only two randomised trials have tested the effect of this treatment in comparison to placebo. These trials currently offer the best available evidence by which to guide clinical practice, though both were limited by methodological issues such as insufficient statistical power. Therefore, the aim of this randomised trial is to compare the effect of ultrasound-guided corticosteroid injection versus placebo for treatment of plantar fasciitis. Methods The trial will be conducted at the La Trobe University Podiatry Clinic and will recruit 80 community-dwelling participants. Diagnostic ultrasound will be used to diagnose plantar fasciitis and participants will be required to meet a range of selection criteria. Participants will be randomly allocated to one of two treatment arms: (i ultrasound-guided injection of the plantar fascia with 1 mL of 4 mg/mL dexamethasone sodium phosphate (experimental group, or (ii ultrasound-guided injection of the plantar fascia with 1 mL normal saline (control group. Blinding will be applied to participants and the investigator performing procedures, measuring outcomes and analysing data. Primary outcomes will be pain measured by the Foot Health Status Questionnaire and plantar fascia thickness measured by ultrasound at 4, 8 and 12 weeks. All data analyses will be conducted on an intention-to-treat basis. Conclusion This will be a randomised trial investigating the effect of dexamethasone injection on pre-specified treatment outcomes in people with plantar fasciitis. Within the parameters of this protocol, the trial findings will be used to make evidence-based recommendations regarding the use of corticosteroid injection for treatment of this

  5. Predictive value of ovarian stroma measurement for cardiovascular risk in polycyctic ovary syndrome: a case control study

    Directory of Open Access Journals (Sweden)

    Loverro Giuseppe

    2010-11-01

    Full Text Available Abstract Background To verify the feasibility of ovarian stromal evaluation and correlate ovarian parameteres (echogenicity and volume with hyperandrogenism, and both cardiovascular and metabolic risk factors in PCOS. Methods Twenty four young PCOS patients and twelve age-matched control women were enrolled. Diagnosis of PCOS was based on the Rotterdam criteria. Ultrasound ovarian study included ovarian volume, stromal volume, stromal area and stromal area/total ovarian area ratio (S/A. Concerning hormones, insulin, LH, FSH, estradiol, androstenedione, testosterone, DHEAS, 17-hydroxy-progesterone, and SHBG were measured during the early follicular phase (days 2-5. Cardiovascular risk factors were represented by fasting plasma levels of glucose, lipids (total and HDL-cholesterol, plasminogen activator inhibitor 1 (PAI-1, von-Willebrand factor (vWF, and adiponectin. Carotid intima-media thickness (C-IMT was measured as a parameter of cardiovascular risk. Results A positive correlation between the S/A ratio and plasma levels of testosterone (p Conclusions This study shows that the ultrasound measurement of ovarian stroma is a predicting factor of hyperandrogenism degree, prothrombotic factors and cardiovascular risk in patients with PCOS.

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  9. Laparoscopic management of ovarian dermoid cysts: a review of 47 cases

    International Nuclear Information System (INIS)

    Kocak, Muberra; Dilbaz, Berna; Ozturk, Nilgun; Dede, Suat; Altay, Meltin; Dilbaz, Serdar; Herbal, Ali

    2004-01-01

    Mature cystic teratomas, often referred to as dermoid cysts, are the most common germ cell tumors of the ovary in the recent years, transvaginal sonographic diagnosis of ovarian dermoid cysts together with the laparascopic approach have greatly improved the treatment of this benign lesion. We retrospectively reviewed the outcome of laparoscopic surgery for suspected ovarian dermoid cysts. The preoperative findings, operative techniques, and postoperative complications were retrospectively reviewed in the women who underwent lpaparoscopic surgey for dermoid cysts, between January 2001 and May 2003. In 47 women aged 21 to 53 years (median, 38.8 years), 93.6% had a unilateral cyst with a diameter of 17 to 108 mm (median 51 mm). Clinical presentations were pain (62%), abnormal vaginal bleeding (21%) and ovarian torsion (2%), while 17%were diagnosed incidently during routine examination. Surgery included cystectomy (57%), total (36%) or partial oophorectomy (6.4%) and laparoscopic assisted vaginal hysterectomy with bilateral salpingo-oophorectomy (2%). During the cyst extraction, minimal spillage occured in 42.5% of the casesand none developed chemical peritonitis. In 2 patients, conversion to laparotomy (4.3%) was required, one for sigmoid colon, injury and one for malignent ovarian tumor detected via frozen section. The median operating time was 80 minutes (range, 35-180 minutes). Using strict afherence to guidelines for preoperative clinical assessment and intraoperative management, laparoscopic treatment of dermoid cysts appers to be a safe procedure. (author)

  10. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  11. Technical guide to evaluate upper limb joints (shoulder, elbow and wrist) by ultrasound

    International Nuclear Information System (INIS)

    Obregon Baez, Luis Rafael

    2014-01-01

    A guideline to follow is offered to radiologists and residents of radiology service of medical imaging, when evaluating by ultrasound the shoulder joints, elbow, wrist. The importance to performing of musculoskeletal ultrasound by its pathology variable is established. The use of appropriate equipment and effective application of the techniques exposed of echography exploration have made enable the valuation of many pathologies with high sensitivity and specificity. The echography has been the musculoskeletal imaging technique that more rapidly has evolved. Currently, this technique has been replaced by magnetic resonance imaging in various clinical fields and also serves as a complement to other techniques. Exposed techniques have been of great benefit for radiologists medical and residents, obtaining with its use a quick guide for the realization of upper limb musculoskeletal ultrasounds. The appropriate and easy techniques are better known for the evaluation of these structures, and so document both sports injuries, as joint and rheumatic diseases [es

  12. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    Science.gov (United States)

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  14. Ultrasound guided percutaneous removal of wooden foreign bodies in the extremities with hydro-dissection technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, HeeJin; Lee, So Yeon; Chung, Eun Chul; Rho, Myung Ho [Dept. of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Lee, Sung Moon; Son, Eun Seok [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Sun Joo [Dept. of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of)

    2015-12-15

    We described the technique of ultrasound (US)-guided percutaneous removal of the foreign bodies (FB) with hydro-dissection in the radiologic department and presented video files of several cases.Four patients referred to the radiology department for US evaluation and US-guided percutaneous removal of the FBs in the upper and lower extremities between November, 2006 and November, 2013 were included in this study. The procedures started with US evaluation for the exact location and shape of the FB. A 5 mm-sized skin incision was made at the site of the nearest point from the FB where no passing arteries or tendons were present. We adopted a hydro dissection technique to separate the FB from adjacent tissue using a 2% lidocaine solution. Injected anesthetics detached the FBs from surrounding tissue and thereby facilitated removal. After the tip of the mosquito forceps reached the FB, the wooden FBs were removed. The mean time required for the entire procedure was approximately 20 minutes. There were no significant complications during the US-guided removal or long-term complications after the procedure. All 4 FBs were successfully removed from the soft tissue under US guidance. Ultrasound-guided percutaneous removal of the FBs with hydro-dissection in the radiology department is a less invasive and safe method over surgical removal in the operating room. Additionally, the use of a guide wire and serial dilator may help minimize soft tissue injury and facilitate the introduction of forceps.

  15. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  16. Reliability of IOTA score and ADNEX model in the screening of ovarian malignancy in postmenopausal women.

    Science.gov (United States)

    Nohuz, Erdogan; De Simone, Luisa; Chêne, Gautier

    2018-04-28

    The IOTA (International Ovarian Tumor Analysis) group has developed the ADNEX (Assessment of Different NEoplasias in the adneXa) model to predict the risk that an ovarian mass is benign, borderline or malignant. This study aimed to test reliability of these risks prediction models to improve the performance of pelvic ultrasound and discriminate between benign and malignant cysts. Postmenopausal women with an adnexal mass (including ovarian, para-ovarian and tubal) and who underwent a standardized ultrasound examination before surgery were included. Prospectively and retrospectively collected data and ultrasound appearances of the tumors were described using the terms and definitions of the IOTA group and tested in accordance with the ADNEX model and were compared to the final histological diagnosis. Of the 107 menopausal patients recruited between 2011 and 2016, 14 were excluded (incomplete inclusion criteria). Thus, 93 patients constituted a cohort in whom 89 had benign cysts (83 ovarian and 6 tubal or para-ovarian cysts), 1 had border line tumor and 3 had invasive ovarian cancers (1 at first stage, 1 at advanced stage and 1 metastatic tumor in the ovary). The overall prevalence of malignancy was 4.3%. Every benign ovarian cyst was classified as probably benign by IOTA score which showed also a high specificity with the totality of probably malignant lesion proved malignant by histological exam. The limit of this score was the important rate of not classified or undetermined cysts. However, the malignancy risks calculated by ADNEX model allowed identifying the totality of malignancy. Thus, the combination of the two methods of analysis showed a sensitivity and specificity rates of respectively 100% and 98%. Evaluation of malignancy risks by these 2 tests highlighted a negative predictive value of 100% (there was no case of false negative) and a positive predictive value of 80%. On the basis of our findings, the IOTA classification and the ADNEX multimodal

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  18. Case study: Solitary intra-cystic papilloma - Advances in consultant radiographic practitioner led ultrasound guided mammotome excisional biopsy

    International Nuclear Information System (INIS)

    Lawson, Sarah

    2008-01-01

    Working practices in Breast Radiology have changed and advanced in the past few years, resulting in an increase in the number of small, indeterminate, non-palpable breast lesions detected. One such lesion is the breast papillary lesion which is essentially an epithelial proliferation with an associate increased risk of breast carcinoma. The current management of an intra-cystic breast papilloma diagnosed by 14 g core biopsy is highly contentious as traditionally management is by surgical biopsy. Recent advances have demonstrated that excision by 8 or 11-gauge Ultrasound guided Mammotomy can be a safe alternative, allowing non-operative removal. The consultant radiographic practitioner role has been integral in establishing the policies needed to support and establish ultrasound guided Mammotome excisional biopsy

  19. Ultrasound Imaging of the Pelvic Floor: linking anatomical findings with clinical symtoms

    OpenAIRE

    Steensma, Anneke

    2009-01-01

    textabstractFor evaluation of pelvic floor and lower urinary tract dysfunction the use of transabdominal ultrasound was first documented in the early eighties, with the translabial [1], transrectal [2] and transvaginal [3, 4] techniques developing somewhat later. To obtain a translabial or transperineal image of the pelvic floor, the transducer (ideally a 3.5-6 MHZ curved array abdominal probe) is placed on the perineum, after covering the transducer with an unpowered glove or thin plastic wr...

  20. Evaluation of ultrasound-guided vascular access in dogs.

    Science.gov (United States)

    Chamberlin, Scott C; Sullivan, Lauren A; Morley, Paul S; Boscan, Pedro

    2013-01-01

    To describe the technique and determine the feasibility, success rate, perceived difficulty, and time to vascular access using ultrasound guidance for jugular vein catheterization in a cardiac arrest dog model. Prospective descriptive study. University teaching hospital. Nine Walker hounds. A total of 27 jugular catheterizations were performed postcardiac arrest using ultrasound guidance. Catheterizations were recorded based on the order in which they were performed and presence/absence of a hematoma around the vein. Time (minutes) until successful vascular access and perceived difficulty in achieving vascular access (scale of 1 = easy to 10 = difficult) were recorded for each catheterization. Mean time to vascular access was 1.9 minutes (95% confidence interval, 1.1-3.4 min) for catheterizations without hematoma, versus 4.3 minutes (1.8-10.1 min) for catheterizations with hematoma (P = 0.1). Median perceived difficulty was 2 of 10 (range 1-7) for catheterizations without hematoma, versus 2 of 10 (range 1-8) for catheterizations with hematoma (P = 0.3). A learning curve was evaluated by comparing mean time to vascular access and perceived difficulty in initial versus subsequent catheterizations. Mean time to vascular access was 2.5 minutes (1.0-6.4 min) in the initial 13 catheterizations versus 3.3 minutes (1.5-7.5 min) in the subsequent 14 catheterizations (P = 0.6). Median perceived difficulty in the first 13 catheterizations (3, range 1-8) was significantly greater (P = 0.049) than median perceived difficulty in the subsequent 14 catheterizations (2, range 1-6). Ultrasound-guided jugular catheterization is associated with a learning curve but is successful in obtaining rapid vascular access in dogs. Further prospective studies are warranted to confirm the utility of this technique in a clinical setting. © Veterinary Emergency and Critical Care Society 2013.