WorldWideScience

Sample records for transrectal ultrasound intra-operative

  1. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  2. Determination of prostate gland volume by transrectal ultrasound

    DEFF Research Database (Denmark)

    Myschetzky, P S; Suburu, R E; Kelly, B S

    1991-01-01

    Seventy six patients underwent transrectal ultrasound examination of the prostate prior to radical prostatectomy. All radical specimens were weighed and measured when freshly excised. Corresponding measurements calculated using transrectal ultrasound dimensions were retrospectively compared with ...... was shown. A modified prolate ellipse formula, using the factor of 0.70, appears to be a more reliable means of estimating gland volume with transrectal ultrasound than the original formula [Width x Height x Length) x 0.523)....

  3. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  4. Intraoperative registered transrectal ultrasound guidance for robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Mohareri, Omid; Ischia, Joseph; Black, Peter C; Schneider, Caitlin; Lobo, Julio; Goldenberg, Larry; Salcudean, Septimiu E

    2015-01-01

    To provide unencumbered real-time ultrasound image guidance during robot-assisted laparoscopic radical prostatectomy, we developed a robotic transrectal ultrasound system that tracks the da Vinci® Surgical System instruments. We describe our initial clinical experience with this system. After an evaluation in a canine model, 20 patients were enrolled in the study. During each procedure the transrectal ultrasound transducer was manually positioned using a brachytherapy stabilizer to provide good imaging of the prostate. Then the transrectal ultrasound was registered to the da Vinci robot by a previously validated procedure. Finally, automatic rotation of the transrectal ultrasound was enabled such that the transrectal ultrasound imaging plane safely tracked the tip of the da Vinci instrument controlled by the surgeon, while real-time transrectal ultrasound images were relayed to the surgeon at the da Vinci console. Tracking was activated during all critical stages of the surgery. The transrectal ultrasound robot was easy to set up and use, adding 7 minutes (range 5 to 14) to the procedure. It did not require an assistant or additional control devices. Qualitative feedback was acquired from the surgeons, who found transrectal ultrasound useful in identifying the urethra while passing the dorsal venous complex suture, defining the prostate-bladder interface during bladder neck dissection, identifying the seminal vesicles and their location with respect to the rectal wall, and identifying the distal prostate boundary at the apex. Real-time, registered robotic transrectal ultrasound guidance with automatic instrument tracking during robot-assisted laparoscopic radical prostatectomy is feasible and potentially useful. The results justify further studies to establish whether the approach can improve procedure outcomes. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    DEFF Research Database (Denmark)

    Holm, Hans Henrik; Torp-Pedersen, S; Myschetzky, P

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound....

  6. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    International Nuclear Information System (INIS)

    Holm, H.H.; Torp-Pedersen, S.; Myschetzky, P.

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound

  7. Reproducibility of contrast-enhanced transrectal ultrasound of the prostate

    NARCIS (Netherlands)

    Sedelaar, J. P.; Goossen, T. E.; Wijkstra, H.; de la Rosette, J. J.

    2001-01-01

    Transrectal three-dimensional (3-D) contrast-enhanced power Doppler ultrasound (US) is a novel technique for studying possible prostate malignancy. Before studies can be performed to investigate the clinical validity of the technique, reproducibility of the contrast US studies must be proven.

  8. The initial experience of trans-rectal ultrasound and biopsy in ...

    African Journals Online (AJOL)

    The initial experience of trans-rectal ultrasound and biopsy in diagnosis of carcinoma prostate in Gezira Hospital for Renal Disease and Surgery (GHRDS). Walaa Eldin Ibraheem, Sami Mahjoub Taha, Mustafa Omran Mansour, Mohammed El Imam Mohamed Ahmed ...

  9. The contribution of periapical nerve block in transrectal ultrasound ...

    African Journals Online (AJOL)

    Objective: Periprostatic nerve block has been shown to be the most effective method to reduce pain during transrectal ultrasound (TRUS) guided prostate biopsy, but the ideal technique remains controversial. The aim of this studywas to compare pain control between bilateral basal block (BBB) alone and BBB combined ...

  10. Intra-operative Ultrasound as a Tool to Assess Free Borders of Primary Vascular Aortic Tumors During Resection

    Directory of Open Access Journals (Sweden)

    R.M. Andersen

    Full Text Available : Introduction: Primary vascular tumors are rare and, in general, have a poor prognosis. Complete resection is associated with a better prognosis. Radical resection depends on safe discrimination of tumor borders. Technical summary: A 54 year old woman presented with abdominal pain. Imaging revealed a mass in the thoracic aorta, highly suspicious of angiosarcoma which was confirmed post-operatively by histological analysis. Open surgery was performed. Prior to clamping of the aorta, intra-operative ultrasound established clear delineation of the tumor borders. Conclusion: Intra-operative ultrasound was, in this case, a safe and easy method to determine the tumor borders, providing a simple guide to in toto tumor removal. Keywords: Angiosarcoma, Intra-operative ultrasound, In toto tumor removal, Fludeoxyglucose positron emission tomography/computed tomography, Magnetic resonance imaging

  11. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  12. Clinically low-risk prostate cancer: evaluation with transrectal doppler ultrasound and functional magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Maria Inês Novis

    2011-01-01

    Full Text Available OBJECTIVES: To evaluate transrectal ultrasound, amplitude Doppler ultrasound, conventional T2-weighted magnetic resonance imaging, spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in localizing and locally staging low-risk prostate cancer. INTRODUCTION: Prostate cancer has been diagnosed at earlier stages and the most accepted classification for low-risk prostate cancer is based on clinical stage T1c or T2a, Gleason score <6, and prostate-specific antigen (PSA <10 ng/ml. METHODS: From 2005 to 2006, magnetic resonance imaging was performed in 42 patients, and transrectal ultrasound in 26 of these patients. Seven patients were excluded from the study. Mean patient age was 64.94 years and mean serum PSA was 6.05 ng/ml. The examinations were analyzed for tumor identification and location in prostate sextants, detection of extracapsular extension, and seminal vesicle invasion, using surgical pathology findings as the gold standard. RESULTS: Sixteen patients (45.7% had pathologically proven organ-confined disease, 11 (31.4% had positive surgical margin, 8 (28.9% had extracapsular extension, and 3 (8.6% presented with extracapsular extension and seminal vesicle invasion. Sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV and accuracy values for localizing low-risk prostate cancer were 53.1%, 48.3%, 63.4%, 37.8% and 51.3% for transrectal ultrasound; 70.4%, 36.2%, 65.1%, 42.0% and 57.7% for amplitude Doppler ultrasound; 71.5%, 58.9%, 76.6%, 52.4% and 67.1% for magnetic resonance imaging; 70.4%, 58.7%, 78.4%, 48.2% and 66.7% for magnetic resonance spectroscopy; 67.2%, 65.7%, 79.3%, 50.6% and 66.7% for dynamic contrast-enhanced magnetic resonance imaging, respectively. Sensitivity, specificity, PPV, NPV and accuracy values for detecting extracapsular extension were 33.3%, 92%, 14.3%, 97.2% and 89.7% for transrectal ultrasound and 50.0%, 77.6%, 13.7%, 95.6% and 75.7% for magnetic resonance imaging

  13. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    Science.gov (United States)

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  14. Prostate cancer prediction using the random forest algorithm that takes into account transrectal ultrasound findings, age, and serum levels of prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Li-Hong Xiao

    2017-01-01

    Full Text Available The aim of this study is to evaluate the ability of the random forest algorithm that combines data on transrectal ultrasound findings, age, and serum levels of prostate-specific antigen to predict prostate carcinoma. Clinico-demographic data were analyzed for 941 patients with prostate diseases treated at our hospital, including age, serum prostate-specific antigen levels, transrectal ultrasound findings, and pathology diagnosis based on ultrasound-guided needle biopsy of the prostate. These data were compared between patients with and without prostate cancer using the Chi-square test, and then entered into the random forest model to predict diagnosis. Patients with and without prostate cancer differed significantly in age and serum prostate-specific antigen levels (P < 0.001, as well as in all transrectal ultrasound characteristics (P < 0.05 except uneven echo (P = 0.609. The random forest model based on age, prostate-specific antigen and ultrasound predicted prostate cancer with an accuracy of 83.10%, sensitivity of 65.64%, and specificity of 93.83%. Positive predictive value was 86.72%, and negative predictive value was 81.64%. By integrating age, prostate-specific antigen levels and transrectal ultrasound findings, the random forest algorithm shows better diagnostic performance for prostate cancer than either diagnostic indicator on its own. This algorithm may help improve diagnosis of the disease by identifying patients at high risk for biopsy.

  15. [Cost analysis of ultrasound-guided transrectal needle biopsy in prostatic carcinoma].

    Science.gov (United States)

    Bissoli, E; Fandella, A; La Torre, E; Faggiano, L; Anselmo, G; Frasson, F

    1998-04-01

    The literature mortality and morbidity rates from prostatic carcinoma prompt to the better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. We evaluated the overall cost of transrectal ultrasound biopsy (TRUSB) of the prostate and investigated the economic impact of the procedures currently used to diagnose prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 1996. The following cost factors were evaluated: personnel, materials, maintenance-equipment depreciation, energy consumption and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide and to consider them in the wider framework of the cost effectiveness of the strategies for the early diagnosis of prostatic cancer. The overall cost of TRUSB was Itl. 249,000, obtained by adding together the costs of: personnel (Itl. 160,000); materials (Itl. 59,000); equipment maintenance and depreciation (Itl. 12,400); energy consumption (Itl. 100); hospital overheads (Itl. 17,500). The literature review points out TRUSB as a clinically invasive tool for diagnosing prostatic carcinoma whose cost-effectiveness is debated. Cadaver studies report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, are very likely to be positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the positivity of exploration and/or transrectal ultrasound findings. Despite the strict application of all these criteria and the critical assessment of the patient's general conditions, TRUSB is indicated for 16% of the male population over 50, with obvious implications. It has been recently

  16. Antibiotic prophylaxis for transrectal ultrasound biopsy of the prostate in Ireland.

    LENUS (Irish Health Repository)

    Smyth, L G

    2012-03-01

    Prostate cancer is the most common solid cancer affecting men in Ireland. Transrectal ultrasound (TRUS) biopsies of the prostate are routinely performed to diagnose prostate cancer. They are, in general, a safe procedure but are associated with a significant risk of infective complications ranging from fever, urinary tract infection to severe urosepsis. At present, there are no recommended national guidelines on the use of antibiotic prophylaxis to minimise the risk of infective complications post-TRUS biopsy.

  17. Prostate cancer prediction using the random forest algorithm that takes into account transrectal ultrasound findings, age, and serum levels of prostate-specific antigen.

    Science.gov (United States)

    Xiao, Li-Hong; Chen, Pei-Ran; Gou, Zhong-Ping; Li, Yong-Zhong; Li, Mei; Xiang, Liang-Cheng; Feng, Ping

    2017-01-01

    The aim of this study is to evaluate the ability of the random forest algorithm that combines data on transrectal ultrasound findings, age, and serum levels of prostate-specific antigen to predict prostate carcinoma. Clinico-demographic data were analyzed for 941 patients with prostate diseases treated at our hospital, including age, serum prostate-specific antigen levels, transrectal ultrasound findings, and pathology diagnosis based on ultrasound-guided needle biopsy of the prostate. These data were compared between patients with and without prostate cancer using the Chi-square test, and then entered into the random forest model to predict diagnosis. Patients with and without prostate cancer differed significantly in age and serum prostate-specific antigen levels (P prostate-specific antigen and ultrasound predicted prostate cancer with an accuracy of 83.10%, sensitivity of 65.64%, and specificity of 93.83%. Positive predictive value was 86.72%, and negative predictive value was 81.64%. By integrating age, prostate-specific antigen levels and transrectal ultrasound findings, the random forest algorithm shows better diagnostic performance for prostate cancer than either diagnostic indicator on its own. This algorithm may help improve diagnosis of the disease by identifying patients at high risk for biopsy.

  18. Assessment of the feasibility of using transrectal ultrasound for postimplant dosimetry in low-dose-rate prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Davies, Rhian Siân, E-mail: rhian.s.davies@wales.nhs.uk; Perrett, Teresa; Powell, Jane; Barber, Jim; Tanguay, Jacob; Button, Michael; Cochlin, Dennis; Smith, Christian; Lester, Jason Francis

    2016-01-01

    A study was performed to establish whether transrectal ultrasound (TRUS)-based postimplant dosimetry (PID) is both practically feasible and comparable to computed tomography (CT)-based PID, recommended in current published guidelines. In total, 22 patients treated consecutively at a single cancer center with low-dose-rate (LDR) brachytherapy for early-stage prostate cancer had a transrectal ultrasound performed immediately after implant (d0-TRUS) and computed tomography scan 30 days after implant (d30-CT). Postimplant dosimetry planning was performed on both image sets and the results were compared. The interobserver reproducibility of the transrectal ultrasound postimplant dosimetry planning technique was also assessed. It was noticed that there was no significant difference in mean prostate D{sub 90} (136.5 Gy and 144.4 Gy, p = 0.2197), V{sub 100} (86.4% and 89.1%, p = 0.1480) and V{sub 150} (52.0% and 47.8%, p = 0.1657) for d30-CT and d0-TRUS, respectively. Rectal doses were significantly higher for d0-TRUS than d30-CT. Urethral doses were available with d0-TRUS only. We have shown that d0-TRUS PID is a useful tool for assessing the quality of an implant after low-dose-rate prostate brachytherapy and is comparable to d30-CT PID. There are clear advantages to its use in terms of resource and time efficiency both for the clinical team and the patient.

  19. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  20. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  1. Enhancement characteristics of benign and malignant focal peripheral nodules in the peripheral zone of the prostate gland studied using contrast-enhanced transrectal ultrasound

    International Nuclear Information System (INIS)

    Tang, J.; Yang, J.-C.; Luo, Y.; Li, J.; Li, Y.; Shi, H.

    2008-01-01

    Aim: To assess the value of contrast-enhanced grey-scale transrectal ultrasound (CETRUS) in predicting the nature of peripheral zone hypoechoic lesions of the prostate. Materials and Methods: Ninety-one patients with peripheral zone hypoechoic lesions on ultrasound were evaluated with CETRUS followed by lesion-specific and sextant transrectal ultrasound-guided biopsies. The enhancement patterns of the lesions were observed and graded subjectively using adjacent peripheral zone tissue as the reference. Time to enhancement (AT), time to peak intensity (TTP) and peak intensity (PI) were quantified within each nodule. Ultrasound findings were correlated with biopsy findings. Results: Transrectal ultrasound-guided biopsy of the hypoechoic lesions revealed prostate cancer in 44 patients and benign prostatic diseases in 47. The intensity of enhancement within the lesions were graded as no enhancement, increased, equal, or decreased compared with adjacent peripheral zone tissue in two, 30, five and seven in the prostate cancer group and 14, 15, four and 14 in the benign group, respectively. The difference was statistically significant (p < 0.05). The peak enhancement intensity was found to be the most optimal discriminatory parameter (area under curve AUC 0.70; 95% CI: 0.58, 0.82). Conclusion: Malignant hypoechoic nodules in the peripheral zone of the prostate are more likely to enhance early and more intensely on CETRUS. A non-enhanced hypoechoic peripheral zone lesion was more likely to be benign

  2. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion

    NARCIS (Netherlands)

    Venderink, W.; Govers, T.M.; Rooij, M. de; Futterer, J.J.; Sedelaar, J.P.M.

    2017-01-01

    OBJECTIVE: Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. MATERIALS AND METHODS: A decision tree and Markov model were

  3. Transrectal Drainage of Deep Pelvic Abscesses Using a Combined Transrectal Sonographic and Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Jeong, Kyung Soon; Lee, Eun Jung; Ko, Ji Ho; Joh, Young Duk; Jung, Gyoo Sik

    2005-01-01

    To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39 years) suffering from pelvic pain, fever and leukocytosis were enrolled in this retrospective study. Ultrasound (US) or computed tomography (CT), which was obtained prior to the procedure, showed pelvic fluid collections that were deemed unapproachable by the percutaneous trans abdominal routes. Transrectal drainage of the pelvic abscess was performed under combined transrectal sonographic and fluoroscopic guidance. The causes of the deep pelvic abscess were postoperative complications (n=7), complications associated with radiation (n=3) and chemotherapy (n=1) as well as unknown causes (n=6). A 7.5-MHz end-firing transrectal US probe with a needle biopsy guide attachment was advanced into the rectum. Once the abscess was identified, a needle was advanced via the biopsy guide and the abscess was punctured. Under US guidance, either a 0.018'or 0.035' guide wire was passed through the needle in the abscess. Under fluoroscopic guidance, the tract was dilated to the appropriate diameter with sequential fascial dilators, and a catheter was placed over the guide wire within the abscess. Clinical success of drainage was determined by a combination closure of the cavity on the follow up images and diminished leukocytosis. The technical and clinical success rate, complications, and patient's discomfort were analyzed. Drainage was technically successful in all patients and there were no serious complications. Surgery was eventually performed in two cases due to fistular formation with the rectum and leakage of the anastomosis site. The procedure was well tolerated in all but one patient who complained of discomfort while the catheter was inserted . The catheter did not interfere with defecation and there was no incidence of catheter

  4. Intra-operative ultrasound-based augmented reality guidance for laparoscopic surgery.

    Science.gov (United States)

    Singla, Rohit; Edgcumbe, Philip; Pratt, Philip; Nguan, Christopher; Rohling, Robert

    2017-10-01

    In laparoscopic surgery, the surgeon must operate with a limited field of view and reduced depth perception. This makes spatial understanding of critical structures difficult, such as an endophytic tumour in a partial nephrectomy. Such tumours yield a high complication rate of 47%, and excising them increases the risk of cutting into the kidney's collecting system. To overcome these challenges, an augmented reality guidance system is proposed. Using intra-operative ultrasound, a single navigation aid, and surgical instrument tracking, four augmentations of guidance information are provided during tumour excision. Qualitative and quantitative system benefits are measured in simulated robot-assisted partial nephrectomies. Robot-to-camera calibration achieved a total registration error of 1.0 ± 0.4 mm while the total system error is 2.5 ± 0.5 mm. The system significantly reduced healthy tissue excised from an average (±standard deviation) of 30.6 ± 5.5 to 17.5 ± 2.4 cm 3 ( p < 0.05) and reduced the depth from the tumor underside to cut from an average (±standard deviation) of 10.2 ± 4.1 to 3.3 ± 2.3 mm ( p < 0.05). Further evaluation is required in vivo, but the system has promising potential to reduce the amount of healthy parenchymal tissue excised.

  5. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  6. Ablative efficiency of lithium triborate laser vaporization and conventional transurethral resection of the prostate: a comparison using transrectal three-dimensional ultrasound volumetry

    Science.gov (United States)

    Gross, Oliver; Sulser, Tullio; Hefermehl, Lukas J.; Strebel, Daniel D.; Largo, Remo; Mortezavi, Ashkan; Poyet, Cédric; Eberli, Daniel; Zimmermann, Matthias; Müller, Alexander; Michel, Maurice S.; Müntener, Michael; Seifert, Hans-Helge; Hermanns, Thomas

    2011-03-01

    Introduction and objectives: It is unknown if tissue ablation following 120W lithium triborate (LBO) laser vaporization (LV) of the prostate is comparable to that following transurethral resection of the prostate (TURP). Therefore, transrectal 3D-ultrasound volumetry of the prostate was performed to compare the efficiency of tissue ablation between LBO-LV and TURP. Methods: Between 03/2008 and 03/2010 110 patients underwent routine LBO-LV (n=61) or TURP (n=49). Transrectal 3D-ultrasound with planimetric volumetry of the prostate was performed pre-operatively, after catheter removal, 6 weeks and 6 months. Results: Median prostate volume was 52.5ml in the LV group and 46.9ml in the TURP group. After catheter removal, median absolute volume reduction (LV: 7.05ml, TURP: 15.8ml) and relative volume reduction (15.9% vs. 34.2%) were significantly lower in the LV group (p<0.001). After 6 weeks/ 6 months, the relative volume reduction but not the absolute remained significantly lower in the LV group. Conclusions: LBO-LV is an efficient procedure evidenced by an absolute tissue ablation not significantly different to that after TURP. However, TURP seems to be superior due to a higher relative tissue ablation. The differences in tissue ablation had no impact on the early clinical outcome. Delayed volume reduction indicates that prostatic swelling occurs early after LV and then decreases subsequently.

  7. Interstitially implanted I125 for prostate cancer using transrectal ultrasound

    International Nuclear Information System (INIS)

    Greenburg, S.; Petersen, J.; Hansen-Peters, I.; Baylinson, W.

    1990-01-01

    Prostate cancer is the third leading cause of death from cancer among men in the United States. Traditional treatments for prostate cancer are prostatectomy, external beam irradiation, and interstitial implantation of Iodine125 (I125) via laparotomy. These treatments are associated with significant morbidity and limitations. Based on experience with I125 interstitial implantation by transrectal ultrasound guidance for early-stage prostate cancer, it seems that this newer method of treatment has greater accuracy of placement and distribution of the isotope and has had few reported complications. The need for a surgical incision has been eliminated. Hospitalization time also has been decreased, creating the need for ambulatory and inpatient nurses to understand the importance of their respective roles in providing coordinated quality care for these patients. Nurses in these departments must have knowledge of the procedure, radiation safety, and common side effects related to the implant

  8. Transrectal ultrasound in male urethritis.

    OpenAIRE

    Ghaly, A F; Taylor, P M; Goorney, B P; Haye, K R

    1994-01-01

    OBJECTIVE--To assess the prevalence of prostatic abnormalities in men with gonococcal and non-gonococcal urethritis using trans-rectal ultrasonic markers. DESIGN--A case control study of patients attending a department of genitourinary medicine with symptoms of urethritis. SETTING--Department of Genitourinary Medicine and Department of Radiology in Manchester Royal Infirmary. RESULTS--A total of 42 patients were recruited to the study: 26 with urethritis and 16 controls. Of the 26 study patie...

  9. Acute bacterial prostatitis after transrectal ultrasound-guided prostate biopsy: epidemiological, bacteria and treatment patterns from a 4-year prospective study.

    Science.gov (United States)

    Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre

    2014-02-01

    To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.

  10. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    Science.gov (United States)

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  11. Transrectal ultrasound of the prostate bed after collagen injection

    Energy Technology Data Exchange (ETDEWEB)

    Salomon, C.G.; Dudiak, C.M.; Pyle, J.M.; Wheeler, J.S.; Waters, W.B.; Flanigan, R.C. [Loyola Univ. Medical Center, Maywood, IL (United States)

    1996-03-01

    Transurethral injection of collagen (TCI) may be used to treat urinary incontinence following radical prostatectomy for prostate cancer. The transrectal ultrasound (TRUS) findings after TCI are described in this report. TRUS exams of four postprostatectomy patients who had undergone TCI were reviewed. Findings were correlated with pathologic specimens obtained at TRUS-guided core biopsy. These histologic specimens were compared with others from postprostatectomy patients who had not undergone TCI. Well defined bladder apex masses of uniform echogenicity, hypoechoic to adjacent fat and muscle, were identified sonographically in all TCI patients. Masses from which positive biopsies were obtained were similar in appearance to those with no malignant. Hypocellular fibrous tissue and foci of acellular loose connective tissue were identified in the biopsies of those patients who had undergone TCI No acellular areas were identified in specimens from patients who had not had TCI. Sequelae of to should be included in the differential diagnosis of perianastomotic masses in postprostatectomy patients. However, the need for biopsy is not obviated as residual or recurrent prostate carcinoma may coexist. 14 refs., 4 figs.

  12. Transrectal Ultrasonographic Findings of Obstructive Male Infertility

    International Nuclear Information System (INIS)

    Kim, Chang Il; Kim, Yun Hyeon; Kang, Heoung Keun; Kim, Jae Kyu; Park, Jin Gyoon; Park, Heung Il; Park, Kwang Seong

    1996-01-01

    To evaluate the usefulness of the transrectal ultrasound in infertile men with suspected obstructive lesions of sperm transport system. We performed transrectal US in 26 infertile patients in whom obstructive lesions of sperm transport system were suspected in physical examination and laboratory data. 7.0 MHz transrectal transducer was used and the content of analysis of sonographic findings was the presence of vas deferens, seminal vesicle and ejaculatory duct. Also, we measured the width of seminal vesicle and diameter of ejaculatory duct. Transrectal US revealed an accurate diagnosis in 12 infertile men who had obstructive lesions and associated abnormalities in distal sperm transport system, two of congenital bilateral absence of the vasa deferentia and seminal vesicles, two of congenital unilateral absence of the vas deferens and seminal vesicle, three of dilatation of seminal vesicles, and five of dilatation of ejaculatory ducts and proximal ducts. The other 14 patients who had normal findings on transrectal US were revealed to have testicular failure (10 patients) and obstruction of proximal sperm transport system (4 patients) which were beyond the field-of-view of transrectal US. Transrectal US is the useful diagnostic method for the evaluation of infertile men with suspected obstructive lesions of sperm transport system. It can possibly decrease the need for the invasive vasography and may be helpful in the guidance of appropriate management of male infertility

  13. Ultrasound to video registration using a bi-plane transrectal probe with photoacoustic markers

    Science.gov (United States)

    Cheng, Alexis; Kang, Hyun Jae; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.

    2016-03-01

    Modern surgical scenarios typically provide surgeons with additional information through fusion of video and other imaging modalities. To provide this information, the tools and devices used in surgery must be registered together with interventional guidance equipment and surgical navigation systems. In this work, we focus explicitly on registering ultrasound with a stereo camera system using photoacoustic markers. Previous work has shown that photoacoustic markers can be used in this registration task to achieve target registration errors lower than the current available systems. Photoacoustic markers are defined as a set of non-collinear laser spots projected onto some surface. They can be simultaneously visualized by a stereo camera system and an ultrasound transducer because of the photoacoustic effect. In more recent work, the three-dimensional ultrasound volume was replaced by images from a single ultrasound image pose from a convex array transducer. The feasibility of this approach was demonstrated, but the accuracy was lacking due to the physical limitations of the convex array transducer. In this work, we propose the use of a bi-plane transrectal ultrasound transducer. The main advantage of using this type of transducer is that the ultrasound elements are no longer restricted to a single plane. While this development would be limited to prostate applications, liver and kidney applications are also feasible if a suitable transducer is built. This work is demonstrated in two experiments, one without photoacoustic sources and one with. The resulting target registration error for these experiments were 1.07mm±0.35mm and 1.27mm+/-0.47mm respectively, both of which are better than current available navigation systems.

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  15. Effectiveness of stress management in patients undergoing transrectal ultrasound-guided biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Chiu LP

    2016-02-01

    Full Text Available Li-Pin Chiu,1,2 Heng-Hsin Tung,3 Kuan-Chia Lin,3 Yu-Wei Lai,1,4 Yi-Chun Chiu,1,4 Saint Shiou-Sheng Chen,1,4 Allen W Chiu1,4 1Division of Urology, Taipei City Hospital, 2University of Taipei, General Education Center, 3School of Nursing, Department of Care Management, National Taipei University of Nursing and Health Science, 4Department of Urology, National Yang-Ming University School of Medicine, Taipei, Taiwan, Republic of China Background: To assess the utilization of stress management in relieving anxiety and pain among patients who undergo transrectal ultrasound (TRUS-guided biopsy of the prostate.  Methods: Eighty-two patients admitted to a community hospital for a TRUS biopsy of the prostate participated in this case-controlled study. They were divided into an experimental group that was provided with stress management and a control group that received only routine nursing care. Stress management included music therapy and one-on-one simulation education. Before and after the TRUS biopsy, the patients’ state-anxiety inventory score, pain visual analogue scale (VAS, respiratory rate, heart rate, and blood pressure were obtained.  Results: There were no differences in baseline and disease characteristics between the two groups. The VAS in both groups increased after the TRUS biopsy, but the difference in pre- and postbiopsy VAS scores was significantly lower in the experimental group (P=0.03. Patients in both groups experienced mild anxiety before and after the biopsy, but those in the experimental group displayed a significantly greater decrease in postbiopsy state-anxiety inventory score compared to the control group (P=0.02.Conclusion: Stress management can alleviate anxiety and pain in patients who received a TRUS biopsy of the prostate under local anesthesia. Keywords: anxiety, pain, stress management, transrectal ultrasound-guided biopsy of the prostate

  16. The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach

    Directory of Open Access Journals (Sweden)

    Kevin Krughoff

    2013-01-01

    Full Text Available Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS- guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB provides a more accurate depiction of disease status than transrectal ultrasound- (TRUS- guided biopsy. We compared 3DMB findings in men with prior TRUS-guided biopsies to determine grade and location of missed cancer. Results were evaluated for 161 men with low-risk organ confined prostate cancer. Results. The number of cancer-positive biopsy zones per patient with TRUS was 1.38 ± 1.21 compared to 3.33 ± 4.06 with 3DMB, with most newly discovered cancers originating from the middle lobe and apex. Approximately half of all newly discovered cancerous zones resulted from anterior 3DMB sampling. Gleason upgrade was recognized in 56 patients using 3DMB. When both biopsy methods found positive cores in a given zone, Gleason upgrades occurred most frequently in the middle left and right zones. TRUS cancer-positive zones not confirmed by 3DMB were most often the basal zones. Conclusion. Most cancer upgrades and cancers missed from TRUS biopsy originated in the middle left zone of the prostate, specifically in anterior regions. Anterior sampling may lead to more accurate diagnosis and appropriate followup.

  17. Automated analysis and interpretation of transrectal ultrasonography images in patients with prostatitis

    NARCIS (Netherlands)

    de la Rosette, J. J.; Giesen, R. J.; Huynen, A. L.; Aarnink, R. G.; van Iersel, M. P.; Debruyne, F. M.; Wijkstra, H.

    1995-01-01

    Transrectal ultrasound (TRUS) offers a valuable complement to digital rectal examination (DRE) in diagnosing prostate diseases. However, in case of prostatitis syndromes, contradictions are found with regard to characteristic ultrasound features in these patients. Therefore we sought for better

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  19. Proper Measurement of the Prostate Volume by Transrectal Ultrasound: Experimental Study about the Prostate with Focal Intravesical Protrusion of the Enlarged Central Gland

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Kyoung; Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    2008-06-15

    To evaluate the proper volume measurement of prostate with focal intravesical protrusion of enlarged central gland by comparison between methods using craniocaudal length from top of protruded central gland and from prostate base near bladder neck to prostate apex. We made 20 prostate models with focal intravesical protrusion (volume range: 20{approx}50 mL, height of protrusion: about 1 cm) using devil's tongue jelly. Two radiologists measured volume of models 3 times by two kinds of methods using craniocaudal length from top of protruded central gland (method 1) and from prostate base near bladder neck (method 2) by transrectal ultrasound. The accuracy of volume measurement of models was evaluated statistically by comparing their average volume to true volume. Intra- and interobserver agreement was also evaluated. Average true volume of models was 31.05 mL. Each average volume using method 1 by two observers was 37.07 mL and 38.56 mL. Each average volume using method 2 was 30.69 mL and 31.55 mL. Volume measurement using method 2 was approximated to true volume of prostate statistically (p = .654, .823). There was no significant inter- and intra-observer variation in both methods. To measure the accurate volume of prostate with focal intravesical protrusion of enlarged central gland, its craniocaudal length should be measured from prostate base near bladder neck

  20. Transrectal ultrasound evaluation in tropical dairy goats: an indispensable tool for the diagnosis of reproductive disorders.

    Science.gov (United States)

    Maia, A L R S; Brandão, F Z; Souza-Fabjan, J M G; Veiga, M O; Balaro, M F A; Facó, O; Fonseca, J F

    2018-04-01

    In Brazil, great milk productivity was achieved after the implementation of a genetic improvement program. However, reproductive efficiency is still far from optimal, possibly due to the high number of undiagnosed disorders that may affect fertility. The aim of this study was to evaluate occurrences of the main reproductive disorders in dairy goats in southeastern Brazil. Data were collected between January 2015 and May 2017 from 23 commercial herds of different breeds, with goats ranging from 8 months to 12 years of age. Transrectal ultrasound exams were performed in 2680 goats. A total of 14.8% of the does showed a disorder in the reproductive tract: hydrometra (10.0%), ovarian follicular cysts (2.3%), gestational loss (1.5%), and hydrosalpinx (1.1%). This was the first study evaluating reproductive disorders in live animals that used a high number of Brazilian dairy goats. Considering that all these diseases affect fertility to different degrees, the performance of transrectal ultrasonography exams twice a year is strongly suggested, in order to guide precocious treatment or discard the animal as soon as possible, thus reducing economic losses in dairy goat farming.

  1. Utility of intra-operative ultrasound in choosing the appropriate site for blood pressure monitoring in Takayasu′s arteritis

    Directory of Open Access Journals (Sweden)

    Prasad Krishnamurthy Narasimha

    2013-01-01

    Full Text Available Takayasu′s arteritis (TA is rare, chronic progressive, pan-endarteritis involving the aorta and its main branches, with a specific predilection for young Asian women. Anaesthesia for TA patients is complicated by their severe uncontrolled hypertension, extreme arterial blood pressure differentials, aortic regurgitation (AR, end-organ dysfunction, stenosis/aneurysms of major blood vessels and difficulties encountered in monitoring arterial blood pressure. We present the usefulness of ultrasound during anaesthetic management of a 35-year-old woman posted for emergency caesarean section due to intra-uterine growth retardation, foetal tachycardia in active labour, who was already diagnosed to have TA along with moderate AR and uncontrolled hypertension, using epidural technique. The use of intra-operative doppler helped resolve the initial dilemma about the diagnosis and treatment of the differential blood pressure between the affected and the normal upper limb in the absence of prior arteriogram.

  2. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A [The Christie Hospital NHS Foundation Trust, Manchester, Greater Manchester (United Kingdom)

    2014-06-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.

  3. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    International Nuclear Information System (INIS)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A

    2014-01-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature

  4. Tissue ablation after 120W greenlight laser vaporization and bipolar plasma vaporization of the prostate: a comparison using transrectal three-dimensional ultrasound volumetry

    Science.gov (United States)

    Kranzbühler, Benedikt; Gross, Oliver; Fankhauser, Christian D.; Hefermehl, Lukas J.; Poyet, Cédric; Largo, Remo; Müntener, Michael; Seifert, Hans-Helge; Zimmermann, Matthias; Sulser, Tullio; Müller, Alexander; Hermanns, Thomas

    2012-02-01

    Introduction and objectives: Greenlight laser vaporization (LV) of the prostate is characterized by simultaneous vaporization and coagulation of prostatic tissue resulting in tissue ablation together with excellent hemostasis during the procedure. It has been reported that bipolar plasma vaporization (BPV) of the prostate might be an alternative for LV. So far, it has not been shown that BPV is as effective as LV in terms of tissue ablation or hemostasis. We performed transrectal three-dimensional ultrasound investigations to compare the efficiency of tissue ablation between LV and BPV. Methods: Between 11.2009 and 5.2011, 50 patients underwent pure BPV in our institution. These patients were matched with regard to the pre-operative prostate volume to 50 LV patients from our existing 3D-volumetry-database. Transrectal 3D ultrasound and planimetric volumetry of the prostate were performed pre-operatively, after catheter removal, 6 weeks and 6 months. Results: Median pre-operative prostate volume was not significantly different between the two groups (45.3ml vs. 45.4ml; p=1.0). After catheter removal, median absolute volume reduction (BPV 12.4ml, LV 6.55ml) as well as relative volume reduction (27.8% vs. 16.4%) were significantly higher in the BPV group (p<0.001). After six weeks (42.9% vs. 33.3%) and six months (47.2% vs. 39.7%), relative volume reduction remained significantly higher in the BPV group (p<0.001). Absolute volume reduction was non-significantly higher in the BPV group after six weeks (18.4ml, 13.8ml; p=0.051) and six months (20.8ml, 18ml; p=0.3). Clinical outcome parameters improved significantly in both groups without relevant differences between the groups. Conclusions: Both vaporization techniques result in efficient tissue ablation with initial prostatic swelling. BPV seems to be superior due to a higher relative volume reduction. This difference had no clinical impact after a follow-up of 6M.

  5. Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Venderink, Wulphert; de Rooij, Maarten; Sedelaar, J P Michiel; Huisman, Henkjan J; Fütterer, Jurgen J

    2016-07-29

    The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration. The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, pimaging-transrectal ultrasound fusion systems which vary in their method of compensating for prostate deformation. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Intra-operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angleindependent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aor...... replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. (E-mail: lindskov@gmail.com) 2016 World Federation for Ultrasound in Medicine & Biology...... with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p , 0.0001), induced systolic backflow (p , 0.003) and reduced systolic jet width (p , 0.0001). After valve replacement, the systolic backflow and jet width were normalized...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  8. Prospective randomized controlled trial comparing three different ways of anesthesia in transrectal ultrasound-guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    M. Tobias-Machado

    2006-04-01

    Full Text Available PURPOSE: To make an objective controlled comparison of pain tolerance in transrectal ultrasound-guided prostatic biopsy using intrarectal topic anesthesia, injectable periprostatic anesthesia, or low-dose intravenous sedation. MATERIALS AND METHODS: One hundred and sixty patients were randomized into 4 groups: group I, intrarectal application of 2% lidocaine gel; group II, periprostatic anesthesia; group III, intravenous injection of midazolam and meperidine; and group IV, control, patients to whom no sedation or analgesic was given. Pain was evaluated using an analogue pain scale graded from 0 to 5. Acceptance of a repetition biopsy, the side effects of the drugs and complications were also evaluated. RESULTS: 18/20 (90% and 6/20 (30% patients reported strong or unbearable pain in the group submitted to conventional biopsy and topical anesthesia (p = 0.23, chi-square = 1.41; whereas those submitted to periprostatic blockade and sedation, severe pain occurred in only 2/60 (3% patients (p < 0.001, chi-square = 40.19 and 3/60 (5% patients (p < 0.001, chi-square = 33.34. Acceptance of repetition of the biopsy was present in only 45% of the patients submitted to conventional biopsy, 60% of those that were given topical anesthesia (p = 0.52, chi-square = 0.4, compared to 100% of those submitted to periprostatic anesthesia (p < 0.01, chi-square = 15.17, and 95% of those who were sedated (p < 0.001, chi-square = 25.97%. CONCLUSIONS: Transrectal ultrasound-guided prostatic biopsy is an uncomfortable experience; however application of periprostatic blockade and intravenous analgesia are associated to higher tolerance of the exam and patient comfort. Low dose sedation by association of intravenous meperidine and midazolam is an emerging and safe outpatient option.

  9. Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing.

    Science.gov (United States)

    Sainz, José A; Fernández-Palacín, Ana; Borrero, Carlota; Aquise, Adriana; Ramos, Zenaida; García-Mejido, José A

    2018-04-01

    The aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland-Altman analysis were used to assess intra- and interobserver measurement's repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p pushing under epidural analgesia. Impact statement What is already known on this subject: The intrapartum transperineal ultrasound parameters can be used with contraction and pushing under epidural analgesia. What the results of this study add to what we know: ITU may be used to evaluate the difficulty of instrumental delivery/to evaluate the difficulty of instrumentation in vaginal operative deliveries and this study concludes that ITU is reproducible during uterine contraction with pushing. What the implications are of these findings for clinical practice and/or further research: Therefore, ITU could be used without difficulty with an adequate intra- and interobserver correlation for the prediction of instrumentation difficulty in operative vaginal deliveries.

  10. Early effect of external beam radiation therapy on the anal sphincter: A study using anal manometry and transrectal ultrasound

    International Nuclear Information System (INIS)

    Birnbaum, E.H.; Dreznik, Z.; Myerson, R.J.; Lacey, D.L.; Fry, R.D.; Kodner, I.J.; Fleshman, J.W.

    1992-01-01

    The early of pelvic irradiation on the anal sphincter has not been previously investigated. This study prospectively evaluated the acute effect of preoperative radiation on anal function. Twenty patients with rectal carcinoma received 4,500 cGy of preoperative external beam radiation. The field of radiation included the sphincter in 10 patients and was delivered above the anorectal ring in 10 patients. Anal manometry and transrectal ultrasound were performed before and four weeks after radiotherapy. No significant difference in mean maximal squeeze or resting pressure was found after radiation therapy. An increase in mean minimal sensory threshold was significant. Histologic examination revealed minimal radiation changes at the distal margin in 8 of 10 patients who underwent low anterior resection and in 1 of 3 patients who underwent abdominoperineal resection. The authors conclude that preoperative radiation therapy has minimal immediate effect on the anal sphincter and is not a major contributing factor to postoperative incontinence in patients after sphincter-saving operations for rectal cancer

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  13. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle; Diagnostico del cancer de prostata: utilidad del antigeno especifico de prostata, ecografia transrectal y aspirado por aguja fina

    Energy Technology Data Exchange (ETDEWEB)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-04-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection.

  14. Distal ureteral calculi: the usefulness of transrectal ultrasound and comparison with intravenous urography

    International Nuclear Information System (INIS)

    Choi, Moon Hae; Yoon, Dae Young; Shim, Joo Eun; Kim, Ho Chul; Yi, Jeong Geun; Choi, Chul Sun; Bae, Sang Hoon; Kim, Ha Young

    1996-01-01

    To determine the usefulness of transrectal ultrasound (TRUS) and to compare TRUS with intravenous urography (IVU) in the evaluation of distal ureteral calculi. TRUS and IVU were performed in 24 patients with distal ureteral calculi. Using TRUS, we evaluated the presence and size of calculus, type of ureteral jet at the affected site and diameter of ureter proximal to calculus, and using IVU evaluated the presence and size of calculus, degree of ureteral obstruction, and degree of hydroureter. TRUS and IVU findings, were compared. In each patient, TRUS detected calculus of the distal ureter;in only 18 cases (75%), were the calculi demonstrated with IVU. In 18 cases where calculi were detected by both modalities, average calculus size was 4.5x3.0mm (longest and shortest dimensions) by IVU, and 6.1x3.7mm by TRUS. Between TRUS and IVU(p 0.05). TRUS appears to be a useful adjunctive method for the evaluation of distal ureteral calculus

  15. WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, D; Usmani, N; Sloboda, R [Cross Cancer Institute, Edmonton, Alberta (Canada); University of Alberta, Edmonton, Alberta (Canada); Meyer, T; Husain, S; Angyalfi, S [Tom Baker Cancer Centre, Calgary, Alberta (Canada); University of Calgary, Calgary, Alberta (Canada); Kay, I [Canterbury District Health Board, Christchurch (New Zealand)

    2014-06-15

    Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset

  16. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    International Nuclear Information System (INIS)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y

    2016-01-01

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  17. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    Energy Technology Data Exchange (ETDEWEB)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y [Mount Sinai Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  18. A Rectourethral Fistula due to Transrectal High-Intensity Focused Ultrasound Treatment: Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Valeria Fiaschetti

    2012-01-01

    Full Text Available Colovesical fistula (CVF is an abnormal connection between the enteric and the urinary systems. The rectourethral fistula (RUF is a possible but extremely rare complication of treatment of prostate cancer with “transrectal High-Intensity Focused Ultrasound (HIFU treatment.” We present a case of CVF due to HIFU treatment of recurrent prostate cancer. The case was assessed with cystography completed with a pelvic CT scan—with MPR, MIP, and VR reconstruction—before emptying the bladder. Since the CT scan confirmed that the fistula involved solely the urethra and excluded even a minimal involvement of the bladder, it was possible to employ a conservative treatment by positioning a Foley catheter of monthly duration, in order to allow the urethra to rest. Still today, after 6 months, the patient is in a good clinical condition and has not shown yet signs of a recurrence of the fistula.

  19. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle

    International Nuclear Information System (INIS)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-01-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection

  20. Postprostatectomy ultrasound-guided transrectal implantation of gold markers for external beam radiotherapy. Technique and complications rate

    Energy Technology Data Exchange (ETDEWEB)

    Langenhuijsen, J.F.; Kiemeney, L.A.L.M.; Witjes, J.A. [Radboud Univ. Nijmegen Medical Center, Nijmegen (Netherlands). Dept. of Urology; Donker, R. [Medical Center Alkmaar (Netherlands). Dept. of Radiation Oncology; McColl, G.M.; Lin, E.N.J.T. van [Radboud Univ. Nijmegen Medical Center, Nijmegen (Netherlands). Dept. of Radiation Oncology

    2013-06-15

    Background and purpose: Postprostatectomy radiotherapy (RT) improves survival in adjuvant and salvage settings. The implantation technique and complications rate of gold markers in the prostate bed for high-precision RT were analyzed. Patients and methods: Patients undergoing postprostatectomy RT for prostate-specific antigen (PSA) relapse or high-risk disease were enrolled in the study. Under transrectal ultrasound guidance, three fine gold markers were implanted in the prostate bed and the technical difficulties of insertion were documented. Patients received our self-designed questionnaires concerning complications and pain. The influence of anticoagulants and coumarins on bleeding was analyzed, as was the effect of potential risk factors on pain. Results: In 77 consecutive patients, failure of marker implantation or marker migration was seen in six cases. Rectal bleeding was reported by 10 patients and 1 had voiding complaints. No macroscopic hematuria persisting for more than 3 days was observed. Other complications included rectal discomfort (n = 2), nausea (n = 1), abdominal discomfort (n = 1), and pain requiring analgesics (n = 4). No major complications were reported. On a 0-10 visual analogue scale (VAS), the mean pain score was 3.7. No clinically significant risk factors for complications were identified. Conclusion: Transrectal implantation of gold markers in the prostate bed is feasible and safe. Alternatives like cone beam computed tomography (CBCT) should be considered, but the advantages of gold marker implantation for high-precision postprostatectomy RT would seem to outweigh the minor risks involved. (orig.)

  1. SU-E-T-285: Revisiting the Nomogram for Intra-Operative Planning Based Pd-103 Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Narayanan, S; Cho, P [Virginia Mason Medical Center, Seattle, WA (United States)

    2014-06-01

    Purpose: The seed implant technique at our institution involves using a published nomogram for seed ordering based on CT based volume studies of the prostate. Ultrasound volume studies are subsequently used in the operating room for planning a modified peripheral loading with urethra sparing seed implant. The purpose of this study is to determine the appropriate modality for prostate volume measurement and creating an updated nomogram for intra-operative planning specific to our technique for pd-103 brachytherapy for efficient seed ordering. Methods: Prostate volumes based on pre-implant CT (Pre-CT), intra-operative ultrasound (TRUS), and post-implant CT (post-CT) studies as well as the total airkerma strength (AKS) of the implants were analyzed for 135 seed implant cases (69 monotherapy, 66 boost). Regression analysis was performed to derive the relationship between the total AKS and pre-CT and TRUS volumes. The correlation between TRUS and pre-CT volumes and TRUS and post-CT volumes were also studied. Results: Ultrasound based prostate volume exhibited a stronger correlation with total AKS than the pre-implant CT volume (R{sup 2} = 0.97 vs 0.88 for monotherapy and 0.96 vs 0.89 for boost). In general the pre-CT overestimated the prostate volume leading to ordering of a larger number of seeds and thus leading to higher number of unused/wasted seeds. Newly derived TRUS based nomogram was better suited for our technique than the published data. The post-implant CT volume closely followed the ultrasound volume (R{sup 2} = 0.88) as compared to pre-implant CT volumes (R{sup 2} = 0.57). Conclusion: In an era of costconscious health care where waste reduction is of utmost importance, an updated technique-specific nomogram is useful for ordering optimal number of seeds resulting in significant cost savings. In addition, our study shows that ultrasound based prostate volume is a better predictor for seed ordering for intra-operative planning than pre-implant CT.

  2. Comparing Three Different Techniques for Magnetic Resonance Imaging-targeted Prostate Biopsies : A Systematic Review of In-bore versus Magnetic Resonance Imaging-transrectal Ultrasound fusion versus Cognitive Registration. Is There a Preferred Technique?

    NARCIS (Netherlands)

    Wegelin, Olivier; Melick, H.H.E.; Hooft, Lotty; Bosch, J L H Ruud; Reitsma, Hans B; Barentsz, Jelle O; Somford, Diederik M

    CONTEXT: The introduction of magnetic resonance imaging-guided biopsies (MRI-GB) has changed the paradigm concerning prostate biopsies. Three techniques of MRI-GB are available: (1) in-bore MRI target biopsy (MRI-TB), (2) MRI-transrectal ultrasound fusion (FUS-TB), and (3) cognitive registration

  3. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  4. Analysis of costs of transrectal prostate biopsy.

    Science.gov (United States)

    Fandella, Andrea

    2011-01-01

    Literature reports mortality and morbidity data from prostatic carcinoma which permit a better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. The aim of this work is to quantify the overall cost of transrectal ultrasound biopsy of the prostate (TRUSB) and to assess the economic impact of current procedures for diagnosing prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 2008. The following cost factors were evaluated: personnel, materials, maintenance/depreciation of the equipment, energy consumption, and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide, and to consider them in the wider framework of the economic effectiveness of strategies for early diagnosis of cancer of the prostate. The overall cost of TRUSB (8 samples) was EUR 249,000, obtained by adding together the costs of: personnel (EUR 160,000); materials (EUR 59,000); equipment maintenance and depreciation (EUR 12,400); energy consumption (EUR0,1); hospital overheads (EUR 17,500). With extended or saturation biopsies the cost increases for the more time needed by pathologists and can be calculated as EUR 300,000. The literature review points out TRUSB as an invasive tool for diagnosing prostatic carcinoma, clinically and economically controversial. Post-mortem data report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity rate from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, have a good probability of being positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the detection by digital exploration and/or positive transrectal ultrasound. CONCLUSIONS. Despite the severe

  5. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  6. Contrast-enhanced versus systematic transrectal ultrasound-guided prostate cancer detection: An overview of techniques and a systematic review

    International Nuclear Information System (INIS)

    Heijmink, Stijn W.T.P.J.; Barentsz, Jelle O.

    2007-01-01

    An overview is given of the current conventional and contrast-specific transrectal ultrasound (TRUS) techniques for prostate imaging that may be used for guiding biopsy. Subsequently, a systematic literature search resulted in inclusion of four studies that directly compared systematic and contrast-enhanced-targeted TRUS-guided biopsy of the prostate. All four studies revealed that contrast-enhanced-targeted TRUS-guided biopsy significantly improved the positive biopsy core rate. In the largest study, the mean Gleason score of the contrast-enhanced-targeted TRUS-guided biopsies was significantly higher than that of the systematic biopsies. Future randomized clinical trials, preferably in a non-academic multi-institutional set-up, will have to be performed to confirm the value of contrast-enhanced-targeted TRUS-guided biopsy in regular clinical practice

  7. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    International Nuclear Information System (INIS)

    Halliwell, O.T.; Yadegafar, G.; Lane, C.; Dewbury, K.C.

    2008-01-01

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications

  8. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    Energy Technology Data Exchange (ETDEWEB)

    Halliwell, O.T. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)], E-mail: hallo99@doctors.org.uk; Yadegafar, G. [Public Health Sciences and Medical Statistics Division, School of Medicine, Southampton General Hospital, Southampton University, Southampton (United Kingdom); Lane, C.; Dewbury, K.C. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)

    2008-05-15

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications.

  9. Transrectal ultrasound imaging and prostate cancer

    NARCIS (Netherlands)

    Goossen, Tjerk; Wijkstra, Hessel

    2003-01-01

    Prostate cancer is one of the most important causes of death from cancer in men. Ultrasound imaging is frequently used in the diagnosis of prostate cancer. This paper presents an overview of currently available ultrasound imaging techniques. The underlying principles and methods are discussed

  10. Prostate cancer multi-feature analysis using trans-rectal ultrasound images

    International Nuclear Information System (INIS)

    Mohamed, S S; Salama, M M A; Kamel, M; El-Saadany, E F; Rizkalla, K; Chin, J

    2005-01-01

    This note focuses on extracting and analysing prostate texture features from trans-rectal ultrasound (TRUS) images for tissue characterization. One of the principal contributions of this investigation is the use of the information of the images' frequency domain features and spatial domain features to attain a more accurate diagnosis. Each image is divided into regions of interest (ROIs) by the Gabor multi-resolution analysis, a crucial stage, in which segmentation is achieved according to the frequency response of the image pixels. The pixels with a similar response to the same filter are grouped to form one ROI. Next, from each ROI two different statistical feature sets are constructed; the first set includes four grey level dependence matrix (GLDM) features and the second set consists of five grey level difference vector (GLDV) features. These constructed feature sets are then ranked by the mutual information feature selection (MIFS) algorithm. Here, the features that provide the maximum mutual information of each feature and class (cancerous and non-cancerous) and the minimum mutual information of the selected features are chosen, yeilding a reduced feature subset. The two constructed feature sets, GLDM and GLDV, as well as the reduced feature subset, are examined in terms of three different classifiers: the condensed k-nearest neighbour (CNN), the decision tree (DT) and the support vector machine (SVM). The accuracy classification results range from 87.5% to 93.75%, where the performance of the SVM and that of the DT are significantly better than the performance of the CNN. (note)

  11. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.

    Science.gov (United States)

    Rodgers, Jessica Robin; Surry, Kathleen; Leung, Eric; D'Souza, David; Fenster, Aaron

    2017-05-01

    Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical

  12. Morbidade da biópsia da próstata transretal guiada por ultrassonografia Morbidity of transrectal ultrasound guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    Raphael Sandes Solha

    2013-04-01

    Full Text Available OBJETIVO: Avaliar a incidência de complicações pós-procedimento nos pacientes submetidos a biópsia prostática transretal guiada por ultrassom no setor de intervenção do Departamento de Diagnóstico por Imagem da Escola Paulista de Medicina - Universidade Federal de São Paulo. MATERIAIS E MÉTODOS: Foram avaliados, via contato telefônico, 132 pacientes submetidos a biópsia de próstata transretal guiada por ultrassom no período de abril/2011 a junho/2011, seguindo o protocolo padrão do nosso setor. RESULTADOS: As complicações pós-biópsia foram categorizadas em maiores e menores de acordo com a necessidade de avaliação médica adicional. Cinquenta e nove pacientes (61,8% apresentaram complicações, e desses, grande parte (86,4% apresentou sintomas leves e autolimitados, considerados menores. Oito pacientes (8,2% apresentaram complicações maiores, sendo que apenas um deles necessitou de tratamento sob regime de internação hospitalar. A retenção urinária foi a complicação maior mais incidente no nosso estudo. CONCLUSÃO: Corroborando outros estudos da literatura, nosso trabalho demonstrou baixa prevalência de complicações maiores após a biópsia prostática transretal.OBJECTIVE: To evaluate the incidence of postprocedural complications in patients submitted to transrectal ultrasound-guided prostate biopsy at the Unit of Intervention, Department of Imaging Diagnosis of Escola Paulista de Medicina - Universidade Federal de São Paulo. MATERIALS AND METHODS: Telephone interviews were conducted with 132 patients who had undergone transrectal ultrasound-guided prostate biopsy in the period from April 2011 to June 2011, according to the institution's protocol. RESULTS: Post-biopsy complications were categorized into two groups - minor and major complications, according to their need for further clinical evaluation. Complications were reported by 59 patients (61.8%, most of them (86.4% with mild and self-limited symptoms

  13. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is located directly in front of the rectum, so the ultrasound exam is performed transrectally in order ... A follow-up examination may also be necessary so that any change in a known abnormality can ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  18. Prostate specific antigen, digital rectal examination, transrectal ultrasound: how accurate are they in determining prostate carcinoma?

    International Nuclear Information System (INIS)

    Gomez, John Anthony M.; Pagdanganan, Ernest Jerome A.; Caedo, Florencio Gerardo O.; Magsino, Benjamin C.; Rivera, Eduardo Ll.; Songco, Jaime S.D.

    1998-01-01

    Prostate cancer is an increasing problem. It is the most frequent malignancy in men past the age of 65 years. In the Philippines, 10-20% of males operated for prostatic obstruction had prostate cancer. The potential for cure is optimized by early detection and treatment of organ confined disease. Digital rectal examination, serum prostatic specific antigen and transrectal ultrasound of the prostate have been advocated individually and collectively to determine prostatic cancer. Our study involved forty-nine males who underwent all three screening modalities. Results of the study showed a statistically significant association between the presence of a nodule and occurrence of prostate cancer, a statistically significant association between hardness in consistency and cancer, a statistically significant difference in mean weight between those with Ca and BPH; a statistically significant difference in mean PSA levels between those with Ca and with BPH; statistically significant association between abnormal PSA levels and Ca; and a statistically significant association between a composite positive result and cancer. On the other hand, there was no statistically significant difference in mean age between those with cancer and those with BPH; there is no statistically significant association between the presence of prostatism and whether the patient has Ca or BPH; and there is no statistically significant difference in the mean duration between those with cancer and those with BPH. The study advocates the use of DRE, serum PSA in determining prostatic Ca as well as TRUS for determining occult carcinoma. (Author)

  19. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    OBJECTIVES: The purpose of this study was to investigate the detection rate of prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsies (mp-MRI-bx) in patients with prior negative transrectal ultrasound biopsy (TRUS-bx) sessions without previous experience of this......-RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...

  1. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

    Science.gov (United States)

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-03-28

    To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue(®). The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue(®) (Bracco, Milan, Italy) and using a Toshiba Aplio(®) ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging ("Vascular Recognition Imaging") involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). In vitro, different volumes of SonoVue(®) were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.

  2. Multi-atlas-based automatic 3D segmentation for prostate brachytherapy in transrectal ultrasound images

    Science.gov (United States)

    Nouranian, Saman; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, S. E.; Abolmaesumi, P.

    2013-03-01

    One of the commonly used treatment methods for early-stage prostate cancer is brachytherapy. The standard of care for planning this procedure is segmentation of contours from transrectal ultrasound (TRUS) images, which closely follow the prostate boundary. This process is currently performed either manually or using semi-automatic techniques. This paper introduces a fully automatic segmentation algorithm which uses a priori knowledge of contours in a reference data set of TRUS volumes. A non-parametric deformable registration method is employed to transform the atlas prostate contours to a target image coordinates. All atlas images are sorted based on their registration results and the highest ranked registration results are selected for decision fusion. A Simultaneous Truth and Performance Level Estimation algorithm is utilized to fuse labels from registered atlases and produce a segmented target volume. In this experiment, 50 patient TRUS volumes are obtained and a leave-one-out study on TRUS volumes is reported. We also compare our results with a state-of-the-art semi-automatic prostate segmentation method that has been clinically used for planning prostate brachytherapy procedures and we show comparable accuracy and precision within clinically acceptable runtime.

  3. Safety of transrectal ultrasound-guided prostate biopsy in patients affected by Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Lucio Dell'Atti

    2017-06-01

    Full Text Available Purpose: Crohn’s disease (CD is a chronic inflammatory condition of the gastrointestinal tract. It is usually considered a contraindication to transrectal ultrasound-guided prostate biopsy (TRUSBx. The aim of this study was to investigate the safety of TRUSBx in a small cohort of patients with CD. Methods: We queried our institutional database clinical data of patients with a diagnosis of CD undergoing TRUSBx, and a retrospective prospective study of 5 patients was planned. All patients enrolled were in the remission phase of CD and asymptomatic. They received the same antibiotic prophylaxis and a povidone-iodine aqueous solution enema before the procedure. A standardized reproducible technique was used with using a ultrasound machine equipped with a 5-9 MHz multifrequency convex probe “end-fire”. The patients were treated under local anaesthesia, and a 14-core biopsy scheme was performed in each patient as first intention. After the procedure each patient was given a verbal numeric pain scale to evaluate tolerability of TRUSBx. Results: TRUSBx was successfully completed in all patients. The number of biopsy cores was 14 (12-16. Of the 5 biopsy procedures performed 40% revealed prostatic carcinoma (PCa with a Gleason score 6 (3+3. No patients required catheterization or admission to the hospital for adverse events after the procedure. The most frequent adverse event was hematospermia (60%, while hematuria was present in 20% of patients and a minimal rectal bleeding in 20% of the patients. No patients reported severe or unbearable pain (score ≥ 8. Conclusions: This study suggests that CD may not be an absolute contraindication to TRUSBx for prostate cancer detection, but still requires a careful patients selection.

  4. Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system.

    Science.gov (United States)

    Baumann, Michael; Mozer, Pierre; Daanen, Vincent; Troccaz, Jocelyne

    2007-01-01

    The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make post-interventional quality controls possible. Since the patient is not immobilized, since the prostate is mobile and due to the fact that probe movements are only constrained by the rectum during biopsy acquisition, the tracking system must be able to estimate rigid transformations that are beyond the capture range of common image similarity measures. We propose a fast and robust multi-resolution attribute-vector registration approach that combines global and local optimization methods to solve this problem. Global optimization is performed on a probe movement model that reduces the dimensionality of the search space and thus renders optimization efficient. The method was tested on 237 prostate volumes acquired from 14 different patients for 3D to 3D and 3D to orthogonal 2D slices registration. The 3D-3D version of the algorithm converged correctly in 96.7% of all cases in 6.5s with an accuracy of 1.41mm (r.m.s.) and 3.84mm (max). The 3D to slices method yielded a success rate of 88.9% in 2.3s with an accuracy of 1.37mm (r.m.s.) and 4.3mm (max).

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated ...

  6. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    Science.gov (United States)

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  7. Contrast-enhanced transrectal ultrasound for prediction of prostate cancer aggressiveness: The role of normal peripheral zone time-intensity curves.

    Science.gov (United States)

    Huang, Hui; Zhu, Zheng-Qiu; Zhou, Zheng-Guo; Chen, Ling-Shan; Zhao, Ming; Zhang, Yang; Li, Hong-Bo; Yin, Li-Ping

    2016-12-08

    To assess the role of time-intensity curves (TICs) of the normal peripheral zone (PZ) in the identification of biopsy-proven prostate nodules using contrast-enhanced transrectal ultrasound (CETRUS). This study included 132 patients with 134 prostate PZ nodules. Arrival time (AT), peak intensity (PI), mean transit time (MTT), area under the curve (AUC), time from peak to one half (TPH), wash in slope (WIS) and time to peak (TTP) were analyzed using multivariate linear logistic regression and receiver operating characteristic (ROC) curves to assess whether combining nodule TICs with normal PZ TICs improved the prediction of prostate cancer (PCa) aggressiveness. The PI, AUC (p < 0.001 for both), MTT and TPH (p = 0.011 and 0.040 respectively) values of the malignant nodules were significantly higher than those of the benign nodules. Incorporating the PI and AUC values (both, p < 0.001) of the normal PZ TIC, but not the MTT and TPH values (p = 0.076 and 0.159 respectively), significantly improved the AUC for prediction of malignancy (PI: 0.784-0.923; AUC: 0.758-0.891) and assessment of cancer aggressiveness (p < 0.001). Thus, all these findings indicate that incorporating normal PZ TICs with nodule TICs in CETRUS readings can improve the diagnostic accuracy for PCa and cancer aggressiveness assessment.

  8. Case study: Solitary intra-cystic papilloma - Advances in consultant radiographic practitioner led ultrasound guided mammotome excisional biopsy

    International Nuclear Information System (INIS)

    Lawson, Sarah

    2008-01-01

    Working practices in Breast Radiology have changed and advanced in the past few years, resulting in an increase in the number of small, indeterminate, non-palpable breast lesions detected. One such lesion is the breast papillary lesion which is essentially an epithelial proliferation with an associate increased risk of breast carcinoma. The current management of an intra-cystic breast papilloma diagnosed by 14 g core biopsy is highly contentious as traditionally management is by surgical biopsy. Recent advances have demonstrated that excision by 8 or 11-gauge Ultrasound guided Mammotomy can be a safe alternative, allowing non-operative removal. The consultant radiographic practitioner role has been integral in establishing the policies needed to support and establish ultrasound guided Mammotome excisional biopsy

  9. Multiparametric ultrasound in the detection of prostate cancer: a systematic review

    OpenAIRE

    Postema, Arnoud; Mischi, Massimo; de la Rosette, Jean; Wijkstra, Hessel

    2015-01-01

    Purpose To investigate the advances and clinical results of the different ultrasound modalities and the progress in combining them into multiparametric UltraSound (mpUS). Methods A systematic literature search on mpUS and the different ultrasound modalities included: greyscale ultrasound, computerized transrectal ultrasound, Doppler and power Doppler techniques, dynamic contrast-enhanced ultrasound and (shear wave) elastography. Results Limited research available on combining ultrasound modal...

  10. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  11. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    Institute of Scientific and Technical Information of China (English)

    Klaus Gottlieb; Paul H Lin; David M Liu; Karl Anders

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord.These tumors are locally aggressive and have a predilection for the ends of the axial skeleton.An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis.The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma.A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo).Transrectal biopsy of chordomas is controversial,however we believe that such concerns are not justified.

  12. Fused-data transrectal EIT for prostate cancer imaging.

    Science.gov (United States)

    Murphy, Ethan K; Wu, Xiaotian; Halter, Ryan J

    2018-05-25

    Prostate cancer is a significant problem affecting 1 in 7 men. Unfortunately, the diagnostic gold-standard of ultrasound-guided biopsy misses 10%-30% of all cancers. The objective of this study was to develop an electrical impedance tomography (EIT) approach that has the potential to image the entire prostate using multiple impedance measurements recorded between electrodes integrated onto an end-fired transrectal ultrasound (TRUS) device and a biopsy probe (BP). Simulations and sensitivity analyses were used to investigate the best combination of electrodes, and measured tank experiments were used to evaluate a fused-data transrectal EIT (fd-TREIT) and BP approach. Simulations and sensitivity analysis revealed that (1) TREIT measurements are not sufficiently sensitive to image the whole prostate, (2) the combination of TREIT  +  BP measurements increases the sensitive region of TREIT-only measurements by 12×, and (3) the fusion of multiple TREIT  +  BP measurements collected during a routine or customized 12-core biopsy procedure can cover up to 76.1% or 94.1% of a nominal 50 cm 3 prostate, respectively. Three measured tank experiments of the fd-TREIT  +  BP approach successfully and accurately recovered the positions of 2-3 metal or plastic inclusions. The measured tank experiments represent important steps in the development of an algorithm that can combine EIT from multiple locations and from multiple probes-data that could be collected during a routine TRUS-guided 12-core biopsy. Overall, this result is a step towards a clinically deployable impedance imaging approach to scanning the entire prostate, which could significantly help to improve prostate cancer diagnosis.

  13. Transrectal ultrasound applicator for prostate heating monitored using MRI thermometry

    International Nuclear Information System (INIS)

    Smith, Nadine Barrie; Buchanan, Mark T.; Hynynen, Kullervo

    1999-01-01

    Purpose: For potential localized hyperthermia treatment of tumors within the prostate, an ultrasound applicator consisting entirely of nonmagnetic materials for use with magnetic resonance imaging (MRI) has been developed and tested on muscle tissue ex vivo and in vivo. Methods and Materials: A partial-cylindrical intracavitary transducer consisting of 16 elements in a 4 x 4 pattern was constructed. It produced a radially propagating acoustic pressure field. Each element of this array (1.5 x 0.75 cm), operating at 1.5 MHz, could be separately powered to produce a desired energy deposition pattern within a target volume. Spatial and temporal temperature elevations were determined using the temperature-dependent proton resonant frequency (PRF) shift and phase subtraction of MR images acquired during ultrasonic heating. Four rabbits were exposed to the ultrasound to raise the local tissue temperature to 45 deg. C for 25 minutes. Six experiments compared thermocouple temperature results to PRF shift temperature results. Results: The tests showed that the multi-element ultrasound applicator was MRI-compatible and allowed imaging during sonication. The induced temperature distribution could be controlled by monitoring the RF power to each transducer element. Therapeutic temperature elevations were easily achieved in vivo at power levels that were about 16% of the maximum system power. From the six thermocouple experiments, comparison between the thermocouple temperature and the PRF temperature yielded an average error of 0.34 ± 0.36 deg. C. Conclusions: The MRI-compatible intracavitary applicator and driving system was able to control the ultrasound field and temperature pattern in vivo. MRI thermometry using the PRF shift can provide adequate temperature accuracy and stability for controlling the temperature distribution

  14. Transrectal ultrasound-guided biopsy sepsis and the rise in carbapenem antibiotic use.

    Science.gov (United States)

    Leahy, Olivia R; O'Reilly, Mary; Dyer, David R; Phillips, David; Grummet, Jeremy P

    2015-12-01

    This study sought to determine the number of hospital admissions for sepsis following transrectal ultrasound-guided (TRUS) biopsy, and the rate of both prophylactic and therapeutic use of carbapenem antibiotics for TRUS biopsy, at a single institution. A retrospective review of prospectively collected data from the medical records electronic database of Cabrini Health, a private metropolitan hospital, was queried for coding of admissions under any admitting urologist for sepsis and prostate-related infections from 2009 to 2012. Records were examined for whether a TRUS biopsy had been performed within 14 days prior and if a therapeutic carbapenem was required. The database also queried the use of carbapenems as prophylaxis in patients undergoing TRUS biopsy. Of the 63 admissions for TRUS biopsy sepsis, multi-drug-resistant organisms were isolated from 26 (41%). Twenty-three admissions were from the 1937 patients who underwent a TRUS biopsy at Cabrini (a sepsis rate of 1.2%) and 40 were following TRUS biopsies at other centres. Thirty-seven (58.7%) patients received therapeutic carbapenems either empirically, or after culture results. Of the 1937 Cabrini TRUS biopsy patients, 154 (8%) were given a carbapenem as prophylaxis, with a rapid increase in prophylactic use over the 4 years studied from 0.25% to 13%. This study did not show evidence of an increasing rate of hospital admissions for TRUS biopsy sepsis at this institution. However, there was a dramatic uptake in prophylactic administration of carbapenems. Increasing carbapenem use may contribute to development of carbapenem-resistant bacteria. Alternative methods of prostate biopsy that avoid sepsis should be considered. © 2014 Royal Australasian College of Surgeons.

  15. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  16. Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers.

    Science.gov (United States)

    Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N

    2013-06-01

    This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Usefulness of transrectal ultrasound-guided 12 core biopsy method in patients with clinically suspected prostate cancer

    International Nuclear Information System (INIS)

    Kwon, Se Hwan; Lim, Joo Won; Park, Seong Jin; Ko, Young Tae; Kim, Yoon Wha

    2000-01-01

    To evaluate the improvement of prostate cancer detection provided by transrectal ultrasound (TRUS)-guided 12 core biopsy method compared with sextant biopsy method. Between June 1997 and February 1999, 29 patients with pathologically proven prostate cancer in 124 patients who underwent TRUS-guided 12 core biopsy method were evaluated. They had abnormal findings in prostate specific antigen (PSA), digital rectal examination (DRE) or TRUS findings. The prostate was diffusely enlarged in all patients on DRE findings and in 15 cases (15/29, 52%), hard nodule was palpated. The average of PSA and prostate specific antigen density (PSAD) is 229.33 ng/ml (1-2280) and 9.14 ng/ml/cm 3 (0.048-142.5), respectively, 12 transrectal biopsy, including 2 transition zones, was performed in both lobe, 6 biopsies were located in both base, middle and apex. Then 2 biopsies were inserted between 3 biopsies in both peripheral zone and 2 biopsies were performed in both transition zone. Each specimen was pathologically examined. The results of pathology were compared with method 1 and 2, respectively. We defined the method 1 and 2 as different sextant biopsy method. The method 1 is that cores are taken from both base, middle and apex and method 2 is that cores are taken from both base, apex and transition zone. TRUS findings were analyzed by two radiologists. Of the 29 patients with prostate cancer, 3 (10%) had carcinomas only in the additional regions as compared with method. When compared with method 2,2 (7.0%) had carcinomas only in the additional regions. 2 patients were same in both cases. TRUS findings were abnormal in 21 cases in all patients whose 12 biopsy method was not helpful. 12 biopsy method was helpful in 2/8 (25%) whose TRUS findings were non-specific and 1/21 (4.8%) whose TRUS findings were abnormal. Small low echoic lesion was seen in one patients whose 12 biopsy method was helpful, but cancer was found in other area. TRUS-guided 12 core biopsy method may be superior to

  18. Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    International Nuclear Information System (INIS)

    Liu, D; Usmani, N; Sloboda, R; Meyer, T; Husain, S; Angyalfi, S; Kay, I

    2014-01-01

    The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used to infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage

  19. The diagnostic value of transrectal ultrasonography combined with prostate specific antigen density in prostate cancer

    International Nuclear Information System (INIS)

    Shen Weidong; Zha Yueqin; Wang Ajun; Hou Jianquan; Ouyang Jun

    2008-01-01

    Objective: To discuss the value of transrectal ultrasound (TRUS) and prostate specific antigen density (PSAD) and prostate specific antigen density of transition zone (PSATZ) for diagnosing prostate cancer. Methods: Chose cases of prostate cancer(PCa) and benign prostate hyperplasia(BPH), each was 19, all the eases were authenticated by pathology. Then compared the characteristic of prostate cancer with prostate specific antigen (PSA) and homologous PSAD, PSATZ. Results: Fourteen cases were discovered by ultrasound among the 19 PCa, the others were only diagnosed as BPH.Among the 14 cases, diffuse pathological changing was found in 1 patient, nodular changing in 13 patients (16 nodules were found). Among the 16 nodules, there were 13 hypoechoic nodules (75%) and 3 hyper echoic or compound echoic nodules (25%), and there were 13 nodules in outer zone and 3 nodules in transition zone.The PSA of PCa and BPH was 8.61-98.65 ng/ml [(48.79±25.34)ng/ml] and 0.58-28.36 ng/ml [(9.73±8.19)ng/ml]. There were no significant differences between the volume of prostate and prostate transition zone (P>0.05), but there were significant differences between the PSAD and PSATZ (P<0.01). That the PCa group was higher than that in the BPH group. Conclusion: It is higher sensitive but bess specific in diagonosis PCa by means of transrectal ultrasound. If it is combined with PSAD and PSATZ, the diagnostic rate of PCa is highly raised. (authors)

  20. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. [Ultrasound physiotherapy treatment of prostatitis].

    Science.gov (United States)

    Talberg, P I; Andryukhin, M I; Mazina, S E; Nikolaev, A L

    2016-12-01

    Develop a method of treatment of prostatitis based on the use of a standard antibiotic, immunomodulatory therapy, and transrectal ultrasound physiotherapy. The dynamics of the accumulation of the antibiotic was investigated in male rats. Sonication was performed immediately before the administration of the antibiotic and its accumulation in the process at 10, 20, 40, 60, 80, 100 min after dosing. The clinical study included 138 patients with chronic prostatitis. Patients of the experimental group, in addition to standard therapy, 10 sessions of transrectal ultrasound physical therapy was performed. The efficacy of treatment was assessed after 14 and 28 days after initiation. and its discussion. Experiments on laboratory animals have shown that the highest concentration and the residence time of antibiotic in the prostate tissue is noted ultrasonic treatment in the period of maximum blood concentration of the test drug. The data obtained allow to determine that the ultrasonic treatment must be performed considering the pharmacokinetics of the antibiotic. In conducting clinical trials on day 14 of treatment and clinical manifestations of prostatitis bacterial microflora in prostatic secretions were no patients in both groups. In 15% of patients of the experimental group the number of leukocytes decreased to the normal range. After 28 days the amount of leukocytes was normal in 51% of patients in the control and 85% in the experimental group. In animal experiments defined the optimal time interval separating the moment of injection of the antibiotic from the beginning of sonication. Clinical studies have shown that the transrectal ultrasound exposure during the period of maximum concentration of the antibiotic in the blood, improves patient outcomes by 33.8%.

  2. Use of dynamic 3-dimensional transvaginal and transrectal ultrasonography to assess posterior pelvic floor dysfunction related to obstructed defecation.

    Science.gov (United States)

    Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader

    2014-02-01

    New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and

  3. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    Science.gov (United States)

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  4. Virtual Ultrasound Guidance for Inexperienced Operators

    Science.gov (United States)

    Caine, Timothy; Martin, David

    2012-01-01

    Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with

  5. Intramuscular diclofenac vs periprostatic lidocaine injection for controlling pain undergoing transrectal ultrasound guided prostatic biopsy

    International Nuclear Information System (INIS)

    Alam, S.I.

    2017-01-01

    Background: Transrectal ultrasound (TRUS) technique for getting prostatic tissue for histopathology is now the standard procedure for malignant lesions of the prostate and imperative diagnostic investigation of patients with clinical specks of prostatic neoplasia. During TRUS guided biopsy, pain control has been important issue therefore, highly potent analgesia before this procedure should be considered on high priority according to current census. Therefore, we compared intramuscular diclofenac injection with sensory blockade of injection lidocaine to abolish pain undergoing prostatic biopsy with TRUS technique. Methods: Total 200 patients were selected for this study having raised PSA values and suspicious nodule on Digital Rectal Examination. These patients were segregated into two groups by randomization. Group Ar eceived intramuscular diclofenac and group Bw ere infiltrated with lidocaine injection for sensory blockade. Results: Patients in group A was having mean age of 64.5±5.8 years while for group B patients was 65.6±4.9 years (p=0.16). Both groups have statistically insignificant difference in their mean PSA values (p=0.24) and mean prostatic volume (p=0.22). The mean pain scores on visual analogue scale in groups A was 3.5±0.8 and in group B it was 2.4±0.8 (p<0.001). 60% group A patients reported with mild or no pain compared to 90% in group B. (p<0.001). Conclusion: Local blockade with lidocaine injection has better pain control as compared to patients experienced pain with intramuscular diclofenac used for prostatic biopsy through TRUS technique.

  6. Intra-operative radiotherapy of malignant tumors: Past, present and perspectives

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Le Bourgeois, J.P.; Ganem, G.

    1986-01-01

    Intra-operative radiotherapy consists of electron or photon radiation which is used during the operative procedure. The treatment field is arranged very precisely after critical organs have been previously arranged out of the field. The target volume includes the remaining tumor which could not be removed surgically, and the surrounding tumor bed which is also felt to be high risk for recurrence. It is preferable to have as little tumor remaining as possible before the intra-operative treatment radiation is given. Intra-operative radiotherapy was developed less than a quarter century ago in Japon, and it was later used in U.S.A. The accumulated experience in Japan and U.S.A. is rewieved here. Intra-operative radiotherapy has only recently been introduced to France. The biology, physics and medical and technical problems of intra-operative therapy are discussed [fr

  7. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  8. Intra-articular distribution pattern after ultrasound-guided injections in wrist joints of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Boesen, Mikael; Jensen, Karl Erik; Torp-Pedersen, Søren

    2007-01-01

    OBJECTIVE: To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA). METHODS: An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg...... with the MRI OMERACT synovitis score (r=0.60, p=0.014), but not with the erosions, bonemarrow oedema scores or any clinical parameters. CONCLUSION: The distribution of contrast on MRI showed patient specific and random patterns after IA injections in active RA wrist joints. The degree of distribution increased...

  9. Correlation of endorectal coil magnetic resonance, transrectal ultrasound and radical prostatectomy findings in assessing extent of prostate cancer in referred urology patients

    International Nuclear Information System (INIS)

    Lavoipierre, A.; Little, A.F.; Greive, K.A.; Royce, P.L.; Snow, R.M.; Frydenberg, M.

    2002-01-01

    Full text: The aim of this study was to compare findings at prostate MR to ultrasound findings and pathology specimens in patients who subsequently underwent radical prostatectomy. Of the 61 patients who underwent composite MR prostate imaging, 39 patients with elevated PSA levels and / or abnormal DRE findings were found to have cancer on transrectal ultrasound (TRUS) and biopsy (random sextant and targeted biopsies). MRI was performed using composite phased array and endorectal coils, using axial T1 and axial, coronal and sagittal T2 weighted images through the prostate, together with axial T1 weighted imaging through the pelvis. Fifteen patients out the 39 patients with documented cancer then underwent radical prostatectomy. The resected specimen pathology was then compared with the MR and TRUS findings. Comparison of findings at MRI with those at prostatectomy indicated approximately 82.4% correlation comparing right side and left side disease (TRUS = 80%). There was a 13.3% false positive for seminal vesicle involvement on MR (TRUS = 0%) and a 10% false negative rate on MR (TRUS 10%) compared with pathology specimens.There was a 26.7% false positive rate of extracapsular extension on MR (TRUS = 0%) and a 6.6% false negative rate on MR (TRUS = 20%) compared with the pathology specimens. Of the 39 patients who had undergone TRUS and biopsy, the disease appeared more extensive on MRI than suspected at ultrasound in 14/39 (35.9%). High resolution MR imaging of the prostate is an acceptable method for assessing the presence of prostate cancer. However, our early experience, in this small series, suggests that there is a high mis-staging of disease on MR as is the case with TRUS, although MR is better than TRUS. The results underscore the need for additional assessment with MR spectroscopy. Copyright (2002) Blackwell Science Pty Ltd

  10. Rating of intra-operative neuro-monitoring results in operative correction of the spinal deformities

    Directory of Open Access Journals (Sweden)

    A. A. Skripnikov

    2015-01-01

    Full Text Available Purpose of the work was filing the electrophysiological phenomena observed in the process of intra-operative neuromonitoring followed by development of the results’ scale of intra-operative neuro-physiological testing of the pyramidal tract. Materials and мethods. The selection for evaluation included data of 147 protocols of intra-operative neuromonitoring in 135 patients (53 males, 82 females, aged from 1 y. 5 m. to 52 years (14,1±0,7 years with spinal deformities of different etiology who underwent instrumentation spinal correction followed by fixation of thoracic / thoracolumbar spine segments using various variants of internal systems of trans-pedicular fixation. Intra-operative neuro-monitoring was performed using system «ISIS IOM» (Inomed Medizintechnik GmbH, Germany. The changes of motor evoked potentials were evaluated according to this scale. Results. Five types of pyramidal system reaction to operative invasion were revealed. According to neurophysiological criteria three grades of the risk of neurological disorders development during operative spinal deformity correction and, correspondingly, three levels of anxiety for the surgeon were defined. Conclusion. Intra-operative neurophysiological monitoring is the effective highly technological instrument to prevent neurological disorders in the spinal deformity. Offered rating scale of the risk of neurological complications gives the possibility to highlight three levels of anxiety during operative invasion.

  11. Staging of rectal cancer by transrectal US

    International Nuclear Information System (INIS)

    Choi, Bo Whan; Ryu, Sie Tae; Park, Ki Soon; Lee, Yul; Chung, Soo Young

    1994-01-01

    To evaluate the accuracy of preoperative staging of rectal cancer by transrectal US(7.5MHz linear array transducer), 17 cases with primary rectal cancer who were examined by transrectal US and histopathologically proven, were analyzed. We correlated the sonographic features of the depth of rectal wall invasion, perirectal fat infiltration and perirectal lymph node metastasis with histopathologic findings. The tumor staging was analyzed according to the TNM classification. The depth of rectal wall invasion was in accordance with histopathologic findings in 15 of 17 cases (accuracy:88.2%). The sensitivity and specificity of transrectal US in predicting perirectal lymph node metastasis were 20% and 75%, respectively (accuracy : 58.8%). The sensitivity and specificity in predicting perirectal fat infiltration were 92.9% and 100%, respectively (accuracy : 94%). Perirectal fat infiltration and depth of rectal wall invasion were preoperatively diagnosed with relatively high accuracy, while perirectal lymph node metastasis with low accuracy. In conclusion, transrectal US is a useful imaging modality for preoperative staging of rectal cancer

  12. Assessment and clinical factors associated with pain in patients undergoing transrectal prostate biopsy.

    Science.gov (United States)

    Gómez-Gómez, E; Ramírez, M; Gómez-Ferrer, A; Rubio-Briones, J; Iborra, I; J Carrasco-Valiente; Campos, J P; Ruiz-García, J; Requena-Tapia, M J; Solsona, E

    2015-09-01

    To quantify the degree of pain experienced by patients who undergo ultrasound-guided transrectal prostate biopsy in standard clinical practice and assess the clinical factors associated with increased pain. Analysis of a multicenter series of patients with prostate biopsy according to standard clinical practice. The biopsy was performed transrectally with a protocol of local anesthesia on the posterolateral nerve bundle. The pain was assessed at 20minutes into the procedure using the visual analog scale (0-10). The degree of pain was analyzed, and the association was studied using a univariate/multivariate analysis of selected clinical variables and the degree of pain. A total of 1188 patients with a median age of 64 years were analyzed. Thirty percent of the biopsies were diagnosed with a tumor. The median pain score was 2, with 65% of the patients reporting a pain score ≤2. The multivariate analysis showed that the prostate volume (RR, 1.34; 95% CI 1.01-1.77; P=.04), having a previous biopsy (RR, 2.25; 95% CI 1.44-3.52; P<.01), age (RR, .63; 95% CI .47-.85; P<.01) and feel palpation (RR, 1.95; 95% CI 1.28-2.96; P<.01) were factors independently associated with greater pain during the procedure. Transrectal biopsy with local anesthesia is a relatively painless technique. Factors such as age, a previous biopsy, pain on being touched and prostate volume were associated with the presence of greater pain during the procedure. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Intra-operative radiotherapy in oncology

    International Nuclear Information System (INIS)

    Gerard, J.P.; Braillon, G.; Sentenac, I.; Calvo, F.; Dubois, J.B.; Saint-Aubert, B.; Guillemin, C.; Roussel, A.

    1991-01-01

    This article is about a treatment used more and more frequently in the world, for some neoplasms: Intra-operative radiotherapy under electron beams. The main neoplasms concerned by this treatment are the stomach, pancreas, rectum, bladder, uterus cervix neoplasms and peritoneal sarcoma [fr

  14. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  15. Dual-Modality PET/Ultrasound imaging of the Prostate

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-01-01

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems

  16. Endoscopic Ultrasound-Guided Drainage of Intra-Abdominal Abscess after Gastric Perforation in a Patient Receiving Ramucirumab and Paclitaxel for Advanced Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Koichiro Mandai

    2017-01-01

    Full Text Available Gastrointestinal perforation is a serious adverse event that occurs in approximately 1% of patients receiving ramucirumab and paclitaxel. A 67-year-old man with unresectable advanced gastric cancer was admitted to our hospital and treated with ramucirumab and paclitaxel. Gastric perforation occurred during the second cycle of chemotherapy. Although the patient’s condition improved without surgery, an abscess developed in the intra-abdominal fluid collection resulting from the perforation. We performed endoscopic ultrasound-guided abscess drainage. The patient improved and was discharged in satisfactory condition. Endoscopic ultrasound-guided drainage is a treatment option for patients with intra-abdominal abscess following gastric perforation due to ramucirumab.

  17. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  18. Ultrasound Imaging of the Pelvic Floor: linking anatomical findings with clinical symtoms

    NARCIS (Netherlands)

    A.B. Steensma (Anneke)

    2009-01-01

    textabstractFor evaluation of pelvic floor and lower urinary tract dysfunction the use of transabdominal ultrasound was first documented in the early eighties, with the translabial [1], transrectal [2] and transvaginal [3, 4] techniques developing somewhat later. To obtain a translabial

  19. Automatic Adjustments of a Trans-oesophageal Ultrasound Robot for Monitoring Intra-operative Catheters

    Science.gov (United States)

    Wang, Shuangyi; Housden, James; Singh, Davinder; Rhode, Kawal

    2017-12-01

    3D trans-oesophageal echocardiography (TOE) has become a powerful tool for monitoring intra-operative catheters used during cardiac procedures in recent years. However, the control of the TOE probe remains as a manual task and therefore the operator has to hold the probe for a long period of time and sometimes in a radiation environment. To solve this problem, an add-on robotic system has been developed for holding and manipulating a commercial TOE probe. This paper focuses on the application of making automatic adjustments to the probe pose in order to accurately monitor the moving catheters. The positioning strategy is divided into an initialization step based on a pre-planning method and a localized adjustments step based on the robotic differential kinematics and related image servoing techniques. Both steps are described in the paper along with simulation experiments performed to validate the concept. The results indicate an error less than 0.5 mm for the initialization step and an error less than 2 mm for the localized adjustments step. Compared to the much bigger live 3D image volume, it is concluded that the methods are promising. Future work will focus on evaluating the method in the real TOE scanning scenario.

  20. Multiparametric ultrasound in the detection of prostate cancer: a systematic review.

    Science.gov (United States)

    Postema, Arnoud; Mischi, Massimo; de la Rosette, Jean; Wijkstra, Hessel

    2015-11-01

    To investigate the advances and clinical results of the different ultrasound modalities and the progress in combining them into multiparametric UltraSound (mpUS). A systematic literature search on mpUS and the different ultrasound modalities included: greyscale ultrasound, computerized transrectal ultrasound, Doppler and power Doppler techniques, dynamic contrast-enhanced ultrasound and (shear wave) elastography. Limited research available on combining ultrasound modalities has presented improvement in diagnostic performance. The data of two studies suggest that even adding a lower performing ultrasound modality to a better performing modality using crude methods can already improve the sensitivity by 13-51 %. The different modalities detect different tumours. No study has tried to combine ultrasound modalities employing a system similar to the PIRADS system used for mpMRI or more advanced classifying algorithms. Available evidence confirms that combining different ultrasound modalities significantly improves diagnostic performance.

  1. The effectivity of periprostatic nerve blockade for the pain control during transrectal ultrasound guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    Alper Otunctemur

    2013-06-01

    Full Text Available Aim: Transrectal ultrasound (TRUS guided prostete biopsy is accepted as a standard procedure in the diagnosis of prostate cancer. Many different protocoles are applied to reduce the pain during the process. In this study we aimed to the comparison of two procedure with intrarectal lidocaine gel and periprostatice nerve blockade respective- ly in addition to perianal intrarectal lidocaine gel on the pain control in prostate biop- sy by TRUS. Methods: 473 patients who underwent prostate biopsy guided TRUS between 2008-2012 were included in the study. 10-point linear visual analog pain scale(VAS was used to evaluate the pain during biopsy. The patients were divided into two groups according to anesthesia procedure. In Group 1, there were 159 patients who had perianal-intrarectal lidocaine gel, in Group 2 there were 314 patients who had periprostatic nerve blockade in addition to intrarectal lidocain gel. The pain about probe manipulation was aseesed by VAS-1 and during the biopsy needle entries was evalu- ated by VAS-2. Results were compared with Mann-Whitney U and Pearson chi-square test. Results: Mean VAS-2 scores in Group 1 and Group 2 were 4.54 ± 1.02 and 2.06 ± 0.79 respectively. The pain score was determined significantly lower in the Group 2 (p = 0.001. In both groups there was no significant difference in VAS-1 scores, patient’s age, prostate volume, complication rate and PSA level. Conclusion: The combination of periprostatic nerve blockade and intrarectal lidocain gel provides a more meaningful pain relief compared to group of patients undergoing intrarectal lidocaine gel.

  2. Reliability of Ultrasound Diameter Measurements in Patients with a Small Asymptomatic Popliteal Artery Aneurysm: An Intra- and Inter-observer Agreement Study.

    Science.gov (United States)

    Zwiers, I; Hoogland, C M T; Mackaay, A J C

    2016-03-01

    In this study the intra- and inter-observer variability of ultrasound measurements of the diameter of the popliteal artery were tested in a group of patients under surveillance for a small (diameter 10-20 mm), asymptomatic popliteal artery aneurysm (PAA). From a group of patients under ultrasound surveillance for bilateral, asymptomatic PAAs, 13 consecutive patients agreed to participate in the study and provided informed consent. The maximum diameter of the popliteal arteries was assessed by a vascular technologist. The same assessment was repeated by a second vascular technologist, unaware of the results of the first measurement. After a week, this protocol was repeated. The intra- and inter-observer reliability of this measurement was calculated using intra-class correlation coefficients (ICCs) and Bland and Altman plots. Of the 10 patients with bilateral and three patients with unilateral PAA, 12 completed the 2 week protocol. A total of 86 measurements were analyzed. The mean diameter of the popliteal arteries was 13.5 ± 3.4 mm. The ICC for the intra-observer reliability of observer 1 was 0.96 (95% CI 0.92-0.99), p .47. The absolute magnitude of the systematic error of both observers was less than 0.135 mm (median 0.00). Ultrasound measurement of the maximum diameter of the popliteal artery is reproducible; hence, it is suitable for making a clinical treatment decision. Its use for surveillance of small, asymptomatic PAAs is justified. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Fast prostate segmentation for brachytherapy based on joint fusion of images and labels

    Science.gov (United States)

    Nouranian, Saman; Ramezani, Mahdi; Mahdavi, S. Sara; Spadinger, Ingrid; Morris, William J.; Salcudean, Septimiu E.; Abolmaesumi, Purang

    2014-03-01

    Brachytherapy as one of the treatment methods for prostate cancer takes place by implantation of radioactive seeds inside the gland. The standard of care for this treatment procedure is to acquire transrectal ultrasound images of the prostate which are segmented in order to plan the appropriate seed placement. The segmentation process is usually performed either manually or semi-automatically and is associated with subjective errors because the prostate visibility is limited in ultrasound images. The current segmentation process also limits the possibility of intra-operative delineation of the prostate to perform real-time dosimetry. In this paper, we propose a computationally inexpensive and fully automatic segmentation approach that takes advantage of previously segmented images to form a joint space of images and their segmentations. We utilize joint Independent Component Analysis method to generate a model which is further employed to produce a probability map of the target segmentation. We evaluate this approach on the transrectal ultrasound volume images of 60 patients using a leave-one-out cross-validation approach. The results are compared with the manually segmented prostate contours that were used by clinicians to plan brachytherapy procedures. We show that the proposed approach is fast with comparable accuracy and precision to those found in previous studies on TRUS segmentation.

  4. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  5. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  7. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    International Nuclear Information System (INIS)

    Wardlaw, Joanna M.; Lewis, Steff

    2005-01-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone

  8. A quantitative analysis of two-dimensional manually segmented transrectal ultrasound axial images in planning high dose rate brachytherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Dabić-Stanković Kata

    2017-01-01

    Full Text Available Background/Aim. Prostate delineation, pre-planning and catheter implantation procedures, in high-dose rate brachytherapy (HDR-BT, are commonly based on the prostate manually segmented transrectal ultrasound (TRUS images. The aim of this study was to quantitatively analyze the consistency of prostate capsule delineation, done by a single therapist, prior to each HDR-BT fraction and the changes in the shape of the prostate capsule during HDR-BT, using two dimensional (2D TRUS axial image. Methods. A group of 16 patients were treated at the Medical System Belgrade Brachytherapy Department with definitive HDRBT. The total applied median dose of 52 Gy was divided into four individual fractions, each fraction being delivered 2– 3 weeks apart. Real time prostate axial visualization and the manual segmentation prior to each fraction were performed using B-K Medical ultrasound. Quantitative analyses, analysis of an area and shape were applied on 2D-TRUS axial images of the prostate. Area analyses were used to calculate the average value of the cross-sectional area of the prostate image. The parameters of the prostate shape, the fractal dimension and the circularity ratio of the prostate capsule contour were estimated at the maximum axial cross section of the prostate image. Results. The sample group consisted of four phases, each phase being performed prior to the first, second, third and fourth HDR-BT fraction, respectively. Statistical analysis showed that during HDR-BT fractions there were no significant differences in the average value of area, as well as in the maximum shape of prostate capsule. Conclusions. Quantitative analysis of TRUS axial prostate segmented images shows a successful capsule delineation in the series of manually segmented TRUS images, and the prostate maximum shape remaining unchanged during HDR-BT fractions.

  9. Intra-operative blood transfusion among adult surgical patients in a ...

    African Journals Online (AJOL)

    This retrospective study was designed to audit the pattern of intra-operative whole blood transfusion among adult surgical patients over a two-year period. Data were collected on the rate of intra-operative transfusion, estimated blood loss, units of donor blood transfused, pattern of use of autologous blood and circumstances ...

  10. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    PURPOSE/OBJECTIVE: Although some controversy remains, most authors agree that post-treatment prostatic biopsy is the best measure of local control in prostate cancer. Brachytherapy series reporting post-implant biopsy results have been few in number, limited in size, and involving older open or combined external beam techniques. The present study was undertaken to assess local control rates as determined by post-implant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound directed, transperineal, computer generated, volume technique. METHOD/MATERIALS: From January 1988 to January 1994, 402 patients received permanent I-125 (285, 71%) or Pd-103 (117, 29%) interstitial brachytherapy as primary treatment for prostatic carcinoma at the Northwest Tumor Institute. Of these, 201 have consented to prostatic biopsy at least 12 months post-implant with a median follow-up of 40 months (range of 12 to 83 months). None had received hormone manipulation. A total of 361 biopsies were performed on 201 patients with a range of 1 to 6 yearly biopsies per patient; 91 receiving multiple biopsies. The other 201 patients were either unable (for geographic reasons) or unwilling to submit for biopsy. However, all patients with a rising PSA or clinical suspicion of recurrence underwent biopsy when possible. The 201 biopsy patients presented with a median age of 69 (range 47 to 89). Stages included 51 T1 (25%), 125 T2a (62%), 22 T2b (11%), and 3 T2c (1%). Gleason sums included 69 2-4 (34%), 117 5-6 (58%), 15 7-10 (7%), and 2 ungraded (1%). The initial PSA was 6.6 (range 0.7 to 74.6). There was no significant difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. 143 received I-125 (71%) prescribed to a minimum peripheral dose of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received Pd-103 prescribed to a

  11. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  12. Decrease in Infection Rate Following Use of Povidone-Iodine During Transrectal Ultrasound Guided Biopsy of the Prostate: A Double Blind Randomized Clinical Trial

    International Nuclear Information System (INIS)

    Ghafoori, Mahyar; Shakiba, Madjid; Seifmanesh, Hamidreza; Hoseini, Kamal

    2012-01-01

    Infection after transrectal ultrasound (TRUS) guided biopsy of the prostate is a major and potentially life-threatening problem. Using antibiotic premedication can not completely eliminate infection after biopsy. We performed this study to determine the value of using povidone-iodine in prevention of post biopsy infection. Totally, 280 patients who were referred for TRUS guided biopsy of the prostate were divided randomly into two equal groups. The case group received an intrarectal mixture of povidone-iodine and lidocaine gel before performing biopsy, while the control group received only lidocaine gel. Patients were followed up for 30 days for possible signs of infection including fever, chills and dysuria. The mean age in the case group was 68.7 ± 7 years and 68.1 ± 7 years in the control group (P = 0.78). Overall, there were signs and symptoms of infection in 78 patients (27.9%), of which 27 (19.3%) were in the case group, while 51 (36.4%) were in the control group (P = 0.001, OR = 2.4, 95% CI = 1.4-4.1). Simple use of widely available povidone-iodine for cleaning the rectum before TRUS guided prostate biopsy can reduce the infection rate

  13. Life-threatening meningitis resulting from transrectal prostate biopsy

    Institute of Scientific and Technical Information of China (English)

    Zhou-Jun Shen; Shan-Wen Chen; Hua Wang; Xie-Lai Zhou; Ju-Ping Zhao

    2005-01-01

    After antibiotic prophylaxis with metronidazole and levofloxacin, a transrectal sextant biopsy was performed under the guide of transrectal ultrasonography (TRUS) for a 75-year-old suspicious patient with prostate adenocarcinoma.Although antibiotics were also given after this procedure, the patient still developed fever, anxious, agrypnia and headache. Blood cultures remained negative. Lumbar puncture was performed and was consistent with Escherichia coli bacterial meningitis.

  14. Transperineal versus transrectal prostate biopsy: Our findings in a ...

    African Journals Online (AJOL)

    2014-07-20

    Jul 20, 2014 ... Conclusion: TPbx is more painful than transrectal prostate biopsy though with a ... study has proven its superiority over transrectal prostate ... DEFF = Estimated design effect = 1. N = × .... block or spinal anesthesia in order to achieve good pain ... elderly and generally less sexually active which may account.

  15. Pre-operative and intra-operative detection of axillary lymph node metastases in 108 patients with invasive lobular breast cancer undergoing mastectomy.

    Science.gov (United States)

    Novak, Jerica; Besic, Nikola; Dzodic, Radan; Gazic, Barbara; Vogrin, Andrej

    2018-02-05

    Despite the recent changes in the treatment of the axilla in selected breast cancer patient, positive sentinel lymph node (SLN) in patients undergoing mastectomy still necessitates axillary lymph node dissection (ALND). In invasive lobular carcinoma (ILC), pre-operative detection of the lymph node metastasis may be demanding due to its unique morphology. The aim of this study was to examine the benefit of preoperative axillary ultrasound (AUS), ultrasound-guided fine-needle aspiration biopsy (US-FNAB), and intra-operative imprint cytology (IIC), in order to avoid two-stage axillary surgery in patients with ILC undergoing mastectomy. The object of this study were 102 patients (median age 52, range 34-73 years) with clinically non-suspicious axilla in whom 108 mastectomies were performed after a pre-operative AUS investigation. Whenever a metastasis was detected in a sentinel lymph node, ALND was done. Reports of the pre-operative AUS investigation, US-FNAB, and IIC were compared with definitive histopathological reports of surgical specimens. In 46 cases lymph node metastases were diagnosed. AUS suspicious lymph nodes were found in 29/108 cases and histopathology confirmed metastases in 22/30 cases. US-FNAB was performed in 29 cases with AUS suspicious lymph nodes. Cytology proved metastases in 11/29 cases. Histopathology confirmed metastases in 10/11 cases with only isolated tumor cells found in one case. IIC investigation was performed in 63 cases and in 10/27 cases metastases were confirmed by histopathology. Pre-operative AUS, US-FNAB, and/or IIC investigation enabled ALND during a single surgical procedure in 20/46 patients with metastases in lymph nodes. Pre-operative AUS, US-FNAB, and/or IIC are/is beneficial in patients with ILC planned for mastectomy in order to decrease the number of two stage axillary procedures.

  16. Intravenous paracetamol for relief of pain during transrectal-ultrasound-guided biopsy of the prostate: A prospective, randomized, double-blind, placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Ozcan Kilic

    2015-11-01

    Full Text Available Transrectal-ultrasound-guided prostate biopsy (TRUS-PBx is the standard procedure for diagnosing prostate cancer. The procedure does cause some pain and discomfort; therefore, an adequate analgesia is necessary to ensure patient comfort, which can also facilitate good-quality results. This prospective, randomized, double-blinded, placebo-controlled study aimed to determine if intravenous (IV paracetamol can reduce the severity of pain associated with TRUS-PBx. The study included 104 patients, scheduled to undergo TRUS-PBx with a suspicion of prostate cancer, that were prospectively randomized to receive either IV paracetamol (paracetamol group or placebo (placebo group 30 minutes prior to TRUS-PBx. All patients had 12 standardized biopsy samples taken. Pain was measured using a 10-point visual analog pain scale during probe insertion, during the biopsy procedure, and 1 hour postbiopsy. All biopsies were performed by the same urologist, whereas a different urologist administered the visual analog pain scale. There were not any significant differences in age, prostate-specific antigen level, or prostate volume between the two groups. The pain scores were significantly lower during probe insertion, biopsy procedure, and 1 hour postbiopsy in the paracetamol group than in the placebo group. In conclusion, the IV administration of paracetamol significantly reduced the severity of pain associated with TRUS-PBx.

  17. Comparative adequecy of colpocystourethrorectography and transrectal sonography in female urinary incontinence

    International Nuclear Information System (INIS)

    Braccini, G.; Pannocchia, P.; Alderigi, L.; Gigoni, R.; Calderazzi, A.

    1991-01-01

    In order to investigate the diagnostic reliability of transrectal US in the study of female urinary incontinence, the authors compared the static images obtained by means of colpocystourethrorectography with the ones obtained with transrectal US. The study population included 30 patients suffering from urinary incontinence. US images were obtained both at rest and during Valsalva's maneuver, some minutes before cystourethrography and employing part of its preparation (vesical filling with 250 cc of iodine contrast medium and positioning of a metallic bead chain in the urethra). On static images obtained with cystourethrography and transrectal US both at rest and during Valsalva, 4 parameters were evaluated: anterior and posterior vesical angles, urethral axis angle, and distance between symphysis pubis and urethral-vesical junction. As for posterior vesical angle, urethral axis angle, and symphysis-junction distance, the statistical comparison of the results did non demonstrate any significant differences. Anterior vesical angle was not included because it is too difficult to measure by transrectal US. In our experience, transrectal US was capable of yielding accurate information similar to that obtained with colpocystourethrorectography. 25 refs

  18. Localization of liver tumors in freehand 3D laparoscopic ultrasound

    Science.gov (United States)

    Shahin, O.; Martens, V.; Besirevic, A.; Kleemann, M.; Schlaefer, A.

    2012-02-01

    The aim of minimally invasive laparoscopic liver interventions is to completely resect or ablate tumors while minimizing the trauma caused by the operation. However, restrictions such as limited field of view and reduced depth perception can hinder the surgeon's capabilities to precisely localize the tumor. Typically, preoperative data is acquired to find the tumor(s) and plan the surgery. Nevertheless, determining the precise position of the tumor is required, not only before but also during the operation. The standard use of ultrasound in hepatic surgery is to explore the liver and identify tumors. Meanwhile, the surgeon mentally builds a 3D context to localize tumors. This work aims to upgrade the use of ultrasound in laparoscopic liver surgery. We propose an approach to segment and localize tumors intra-operatively in 3D ultrasound. We reconstruct a 3D laparoscopic ultrasound volume containing a tumor. The 3D image is then preprocessed and semi-automatically segmented using a level set algorithm. During the surgery, for each subsequent reconstructed volume, a fast update of the tumor position is accomplished via registration using the previously segmented and localized tumor as a prior knowledge. The approach was tested on a liver phantom with artificial tumors. The tumors were localized in approximately two seconds with a mean error of less than 0.5 mm. The strengths of this technique are that it can be performed intra-operatively, it helps the surgeon to accurately determine the location, shape and volume of the tumor, and it is repeatable throughout the operation.

  19. Biopsy of the prostate guided by transrectal ultrasound: relation between warfarin use and incidence of bleeding complications

    Energy Technology Data Exchange (ETDEWEB)

    Ihezue, C.U. [Department of Radiology, Southampton General Hospital (United Kingdom); Smart, J. [Department of Radiology, Southampton General Hospital (United Kingdom); Dewbury, K.C. [Department of Radiology, Southampton General Hospital (United Kingdom)]. E-mail: keith.dewbury@suht.swest.nhs.uk; Mehta, R. [Department of Radiology, Southampton General Hospital (United Kingdom); Burgess, L. [Department of Radiology, Southampton General Hospital (United Kingdom)

    2005-04-01

    AIM: To determine the relation between warfarin use and the frequency of bleeding complications after biopsy of the prostate guided by transrectal ultrasound (TRUS). METHODS: Overall, 1022 consecutive patients with suspected prostatic disease were followed after biopsy. Warfarin and aspirin use was determined on the day of the procedure. A TRUS-guided biopsy was performed and patients were offered a questionnaire to complete 10 days after the procedure, to determine any immediate or delayed bleeding complications. Follow-up telephone calls were made to those who had not replied within the stipulated period. RESULTS: Of the 1000 patients who replied, 49 were receiving warfarin, 220 were receiving aspirin and 731 were not receiving any anticoagulant drugs. Of the 49 subjects reporting current use of warfarin, 18 (36.7%) experienced haematuria, compared with 440 (60.2%) of the patients receiving no anti-coagulant drugs who reported haematuria. This was statistically significant (p=0.001). Of the group receiving warfarin, 4 (8.2%) experienced haematospermia whereas 153 (21%) of the group receiving no anticoagulant medication reported haematospermia. This difference also was statistically significant (p=0.030). Rectal bleeding was experienced by 7 (14.3%) of the group receiving warfarin compared with 95 (13%) in the group without anticoagulant medication, but this was not statistically significant (p=0.80). We also demonstrated that there was no statistically significant association between the severity of the bleeding complications and medication with warfarin. CONCLUSION: None of the group receiving warfarin experienced clinically important bleeding complications. Our results suggest that the frequency and severity of bleeding complications were no worse in the warfarin group than in the control group and that discontinuing anticoagulation medication before prostate biopsy may be unnecessary.

  20. Biopsy of the prostate guided by transrectal ultrasound: relation between warfarin use and incidence of bleeding complications

    International Nuclear Information System (INIS)

    Ihezue, C.U.; Smart, J.; Dewbury, K.C.; Mehta, R.; Burgess, L.

    2005-01-01

    AIM: To determine the relation between warfarin use and the frequency of bleeding complications after biopsy of the prostate guided by transrectal ultrasound (TRUS). METHODS: Overall, 1022 consecutive patients with suspected prostatic disease were followed after biopsy. Warfarin and aspirin use was determined on the day of the procedure. A TRUS-guided biopsy was performed and patients were offered a questionnaire to complete 10 days after the procedure, to determine any immediate or delayed bleeding complications. Follow-up telephone calls were made to those who had not replied within the stipulated period. RESULTS: Of the 1000 patients who replied, 49 were receiving warfarin, 220 were receiving aspirin and 731 were not receiving any anticoagulant drugs. Of the 49 subjects reporting current use of warfarin, 18 (36.7%) experienced haematuria, compared with 440 (60.2%) of the patients receiving no anti-coagulant drugs who reported haematuria. This was statistically significant (p=0.001). Of the group receiving warfarin, 4 (8.2%) experienced haematospermia whereas 153 (21%) of the group receiving no anticoagulant medication reported haematospermia. This difference also was statistically significant (p=0.030). Rectal bleeding was experienced by 7 (14.3%) of the group receiving warfarin compared with 95 (13%) in the group without anticoagulant medication, but this was not statistically significant (p=0.80). We also demonstrated that there was no statistically significant association between the severity of the bleeding complications and medication with warfarin. CONCLUSION: None of the group receiving warfarin experienced clinically important bleeding complications. Our results suggest that the frequency and severity of bleeding complications were no worse in the warfarin group than in the control group and that discontinuing anticoagulation medication before prostate biopsy may be unnecessary

  1. Outcome of renal transplantation with and without intra-operative diuretics.

    Science.gov (United States)

    Hanif, F; Macrae, A N; Littlejohn, M G; Clancy, M J; Murio, E

    2011-01-01

    This paper presents an e-survey of current clinical practice of use of intra-operative diuretics during renal transplantation in the United Kingdom and a study to compare outcome of renal transplants carried out with or without intra-operative diuretics in our centre. An e-mail questionnaire to renal transplant surgeons exploring their practice of renal transplantation with or without intra-operative diuretics, the type of a diuretic/s if used and the relevant doses. An observational study comparing the outcome of renal transplant recipients, group no-diuretics (GND, n = 80) carried out from 2004 to 2008 versus group diuretics (GD n = 69) renal transplant recipients who received intra-operative diuretics over a one year period is presented. Outcome measures were incidence of delayed graft function and a comparison of graft survival in both groups. Forty surgeons answered from 18 transplant centres with a response rate of 67%. 13 surgeons do not use diuretics. Mannitol is used by 10/40, Furosemide 6/40 and 11 surgeons use a combination of both. In comparative study there was no significant overall difference in one year graft survival of GD versus GND (N = 65/69, 94% and 75/80, 94% respectively, p = 0.08) and the incidence of delayed graft function was also comparable (16/69, 23% and 21/80, 26% respectively, p = 0.07). The donor characteristics in both groups were comparable. The study showed variation in clinical practice on the use of intra-operative diuretics in renal transplantation and it did not demonstrate that the use of diuretics can improve renal graft survival. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Laparoscopic subtotal colectomy with transrectal extraction of the colon and ileorectal anastomosis.

    Science.gov (United States)

    Awad, Ziad T

    2012-03-01

    Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Five trocars (one 12 mm and four 5 mm) were used. The video describes the technique of performing laparoscopic subtotal colectomy, laparoscopic cholecystectomy, transrectal removal of the gallbladder and the entire colon, and intracorporeal stapled ileorectal anastomosis in a 27-year-old female with colonic inertia and biliary dyskinesia. There were no intraoperative complications. The operating time was 180 min. Blood loss was 10 cc. The patient was discharged home on postoperative day 4. Laparoscopic subtotal colectomy with transrectal removal of the colon is a safe and effective procedure that can be added to the armamentarium of surgeons performing laparoscopic colon surgery. This technique may provide both an attractive way to reduce abdominal wall morbidity and a bridge to NOTES colon surgery.

  3. Pediatric awake craniotomy and intra-operative stimulation mapping.

    Science.gov (United States)

    Balogun, James A; Khan, Osaama H; Taylor, Michael; Dirks, Peter; Der, Tara; Carter Snead Iii, O; Weiss, Shelly; Ochi, Ayako; Drake, James; Rutka, James T

    2014-11-01

    The indications for operating on lesions in or near areas of cortical eloquence balance the benefit of resection with the risk of permanent neurological deficit. In adults, awake craniotomy has become a versatile tool in tumor, epilepsy and functional neurosurgery, permitting intra-operative stimulation mapping particularly for language, sensory and motor cortical pathways. This allows for maximal tumor resection with considerable reduction in the risk of post-operative speech and motor deficits. We report our experience of awake craniotomy and cortical stimulation for epilepsy and supratentorial tumors located in and around eloquent areas in a pediatric population (n=10, five females). The presenting symptom was mainly seizures and all children had normal neurological examinations. Neuroimaging showed lesions in the left opercular (n=4) and precentral or peri-sylvian regions (n=6). Three right-sided and seven left-sided awake craniotomies were performed. Two patients had a history of prior craniotomy. All patients had intra-operative mapping for either speech or motor or both using cortical stimulation. The surgical goal for tumor patients was gross total resection, while for all epilepsy procedures, focal cortical resections were completed without any difficulty. None of the patients had permanent post-operative neurologic deficits. The patient with an epileptic focus over the speech area in the left frontal lobe had a mild word finding difficulty post-operatively but this improved progressively. Follow-up ranged from 6 to 27 months. Pediatric awake craniotomy with intra-operative mapping is a precise, safe and reliable method allowing for resection of lesions in eloquent areas. Further validations on larger number of patients will be needed to verify the utility of this technique in the pediatric population. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  5. The detection of prostatic carcinoma. 4- or 7-MHz transrectal ultrasonography?

    NARCIS (Netherlands)

    Vleeming, R.; Noordzij, J. W.; de Reijke, T. M.; Kurth, K. H.

    1993-01-01

    In this prospective study a comparison of 4-versus 7-MHz transrectal ultrasonography for the detection of prostatic carcinoma is reported. A total of 150 prostates were biopsied due to suspicion of malignancy arising at either digital rectal examination, 4- and/or 7-MHz transrectal ultrasonography,

  6. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  7. Transrectal Mesh Erosion Requiring Bowel Resection.

    Science.gov (United States)

    Kemp, Marta Maria; Slim, Karem; Rabischong, Benoît; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz

    To report a case of a transrectal mesh erosion as complication of laparoscopic promontofixation with mesh repair, necessitating bowel resection and subsequent surgical interventions. Sacrocolpopexy has become a standard procedure for vaginal vault prolapse [1], and the laparoscopic approach has gained popularity owing to more rapid recovery and less morbidity [2,3]. Mesh erosion is a well-known complication of surgical treatment for prolapse as reported in several negative evaluations, including a report from the US Food and Drug Administration in 2011 [4]. Mesh complications are more common after surgeries via the vaginal approach [5]; nonetheless, the incidence of vaginal mesh erosion after laparoscopic procedures is as high as 9% [6]. The incidence of transrectal mesh exposure after laparoscopic ventral rectopexy is roughly 1% [7]. The diagnosis may be delayed because of its rarity and variable presentation. In addition, polyester meshes, such as the mesh used in this case, carry a higher risk of exposure [8]. A 57-year-old woman experiencing genital prolapse, with the cervix classified as +3 according to the Pelvic Organ Prolapse Quantification system, underwent laparoscopic standard sacrocolpopexy using polyester mesh. Subtotal hysterectomy and bilateral adnexectomy were performed concomitantly. A 3-year follow-up consultation demonstrated no signs or symptoms of erosion of any type. At 7 years after the surgery, however, the patient presented with rectal discharge, diagnosed as infectious rectocolitis with the isolation of Clostridium difficile. She underwent a total of 5 repair surgeries in a period of 4 months, including transrectal resection of exposed mesh, laparoscopic ablation of mesh with digestive resection, exploratory laparoscopy with abscess drainage, and exploratory laparoscopy with ablation of residual mesh and transverse colostomy. She recovered well after the last intervention, exhibiting no signs of vaginal or rectal fistula and no recurrence

  8. [Treatment with non-steroidal anti-inflammatory drugs in patients with amicrobial chronic prostato-vesiculitis: transrectal ultrasound and seminal findings].

    Science.gov (United States)

    Vicari, E; La Vignera, S; Battiato, C; Arancio, A

    2005-03-01

    The aim of this paper was to evaluate the efficacy (0= none; 3= fully) of the treatment with nonsteroidal anti-inflammatory (NSAI) drugs on (a) gland post-inflammatory echopattern, by transrectal ultrasound (TRUS); (b) seminal cytologic (WBC concentration and spermiophagies) and (c) >2 physicochemical inflammatory parameters in patients with chronic amicrobial prostato-vesiculitis (PV). Thirty-five patients with PV received NSAI drugs in the following intermittently steps (over a 3-month period): 1) Pygeum 100 mg twice a day for 14 consecutive days per month; 2) flavoxate-propyphenazone 400 mg twice a day plus Serratiopeptidase 10 000 U twice a day for the subsequent 14 days per month. All patients underwent semen analysis and TRUS scans in the pre-treatment and after 3 months of therapy. The fully (a+b+c) efficacy rate, through an improvement of TRUS prostatic or vesicular echopattern in 37.1% and 22.8% respectively, was higher than that registered with an improvement of only 1 or 2 endpoints. Altogether, the following TRUS findings showed reductions (range 25-40%): prostate volume and hypochogenicity (51.4%); vesicular antero-posterior diameter (APD) in the 43.5% and 28.6% of the uni- and bilateral PV respectively; vesicular wall tickness (25%); unilateral vesicular honeycomb aspect (36%). No efficacy, mainly related to immodified TRUS prostatic or vesicular echopattern in 51.4% and 65.7% respectively, was observed on: areas of prostatic hyperechogenicity; peri-prostatic venous congestion; vesicular APD 21 mm (with honeycomb aspect). In PV patients, the treatment with NSAI compounds was effective when it was enable to produce multiple positive effects, mainly through TRUS changes.

  9. Premedication with oral Dextromethorphan reduces intra-operative Morphine requirement

    Directory of Open Access Journals (Sweden)

    R Talakoub

    2005-09-01

    Full Text Available Background: Intra-operative pain has adverse effects on hemodynamic parameters. Due to complications of opioids for pain relief, using non-opioids medication is preferred. The purpose of this study was to investigate the effect of oral dextrometorphan premedication on intra-operative Morphine requirement. Methods: After approval of the Ethics committee and informed consent, 40 adult patients who stand in American Society of Anesthesiologists Physical Status I and II, under general anesthesia for elective laparatomy were selected and classified in two equal groups randomly. In group A, oral dextromethorphan (60mg was administered at 10 PM and 6 AM preoperatively. In group B, placebo (dextrose was administered. After induction of general anesthesia and before skin incision, intravenous morphine (0.01 mg/kg was administered. During surgery, when systolic blood pressure or heart rate was increased more than 20% of the preoperative baseline, 0.01 mg/kg morphine was administered. At the end of surgery, the totally prescribed morphine (mg/kg and maximal increase in systolic, diastolic, mean arterial blood pressure and heart rate relative to the baseline values were calculated and statistically compared with student’s t-test. Results: The mean dose of administered morphine during surgery was significantly less in group A than group B (P<0.0001. Also, Maximal increase in systolic, diastolic and mean arterial blood pressure was significantly less in group A (p<0.003, p<0.004, p<0.0001, respectively. There was no significant difference in maximal heart rate increase between two groups (p<0.114. Conclusion: Oral dextromethorphan premedication may decrease intra-operative morphine requirement and reduce maximal increase in systolic and mean arterial blood pressure during surgery. Key words: Dextromethorphan, Morphine, Intra-operative, Premedication Hemodynamic

  10. Applicable value of real time interventional ultrasound guidance in family planning reproduction operation

    International Nuclear Information System (INIS)

    Wu Guoping; Zou Dongfang; Sun Jian; Dong Weihua

    2007-01-01

    Objective: To determine the clinical value of real time interventional ultrasound guidance in family planning reproduction operation. Methods: Under the guidance of ultrasound monitoring, 522 cases with high risk and difficult uterine operation were undertaken in our department. Results: The abdominal endoscopic contraceptive uterine operation under real time ultrasound monitoring was carried out for 522 cases in 4 years, with successful rates for high risk pregnancy as 287/289 cases, high risk troublesome withdrawal of contraceptive ring as 129/130 cases and puzzling uterine operation as 103/103 cases. The total successful rate reached 99.42%, without uterine rupture and other complications. Conclusion: The former complex, blind and difficult uterine operations turn to be simple, safe and reliable under the guidance of real time ultrasound. (authors)

  11. Observation of behavioural markers of non-technical skills in the operating room and their relationship to intra-operative incidents.

    Science.gov (United States)

    Siu, Joey; Maran, Nikki; Paterson-Brown, Simon

    2016-06-01

    The importance of non-technical skills in improving surgical safety and performance is now well recognised. Better understanding is needed of the impact that non-technical skills of the multi-disciplinary theatre team have on intra-operative incidents in the operating room (OR) using structured theatre-based assessment. The interaction of non-technical skills that influence surgical safety of the OR team will be explored and made more transparent. Between May-August 2013, a range of procedures in general and vascular surgery in the Royal Infirmary of Edinburgh were performed. Non-technical skills behavioural markers and associated intra-operative incidents were recorded using established behavioural marking systems (NOTSS, ANTS and SPLINTS). Adherence to the surgical safety checklist was also observed. A total of 51 procedures were observed, with 90 recorded incidents - 57 of which were considered avoidable. Poor situational awareness was a common area for surgeons and anaesthetists leading to most intra-operative incidents. Poor communication and teamwork across the whole OR team had a generally large impact on intra-operative incidents. Leadership was shown to be an essential set of skills for the surgeons as demonstrated by the high correlation of poor leadership with intra-operative incidents. Team-working and management skills appeared to be especially important for anaesthetists in the recovery from an intra-operative incident. A significant number of avoidable incidents occur during operative procedures. These can all be linked to failures in non-technical skills. Better training of both individual and team in non-technical skills is needed in order to improve patient safety in the operating room. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  12. Intra-operative parathyroid hormone measurements – experience of ...

    African Journals Online (AJOL)

    Background. Surgery is the treatment of choice for symptomatic primary hyperparathyroidism. The majority of research concerning intra-operative parathyroid hormone (ioPTH) measurements is conducted in university hospitals. Whether ioPTH measurements are feasible and useful in predicting the presence of remaining ...

  13. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Izadpanahi

    2017-01-01

    Full Text Available Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx. Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30–60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p=0.017. Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx.

  14. A comparison of pain control and complications using three different ways of anesthesia in patients undergoing transrectal ultrasound-guided prostate biopsy

    Directory of Open Access Journals (Sweden)

    Hamid Mazdak

    2018-01-01

    Full Text Available Background: We aim to compare the degree of pain control and complications in three types of anesthesia using periprostatic nerve block (PPNB plus intrarectal local anesthesia (IRLA, low-dose spinal anesthesia, and intravenous (IV sedation in patients undergoing transrectal ultrasound (TRUS-guided prostate biopsy. Materials and Methods: In this clinical trial study, 106 patients were participated from December 2015 to December 2016 at Alzahra Hospital, Isfahan, Iran. Patients were randomly allocated into three groups to receive PPNB plus IRLA (n = 36, low-dose spinal anesthesia (n = 35 and IV sedation (n = 35 before TRUS-guided prostate biopsy. Pain scores were recorded using a 10 point visual analog scale right after the biopsy was done. Early and late complications were assessed using a questionnaire after the procedure and in follow-up of patients. Results: Overall, the pain score in the low-dose spinal anesthesia group was significantly lower than PPNB plus IRLA and IV sedation groups (P < 0.001. The differences in pain scores between PPNB plus IRLA group and IV sedation group were not significant (P = 0.30. Urinary retraction and fever were significantly more frequent in low-dose spinal anesthesia and IV sedation, retrospectively (P = 0.04, P = 0.03. No significant difference in late complications was found among the groups. Conclusion: This study demonstrates that low-dose spinal anesthesia is superior to PPNB plus IRLA and IV sedation in terms of pain controlling and was associated with higher tolerance of the examination and patient comfort.

  15. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    Science.gov (United States)

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  16. Combination of Tramadol and Lidocaine for Pain Control During Transrectal Ultrasound-guided Prostate Biopsy: A Randomized Double-blinded Study.

    Science.gov (United States)

    Sen, Haluk; Seckiner, Ilker; Bayrak, Omer; Sen, Elzem; Erturhan, Sakip; Yagci, Faruk

    2015-06-01

    To evaluate the efficacy of tramadol, lidocaine, and a combination of tramadol with lidocaine in pain relief using periprostatic nerve block technique by guidance of transrectal ultrasound (TRUS) before the prostate biopsy (PBx). For the indication of TRUS-PBx, the patients with a prostate-specific antigen (PSA) level >4.0 ng/mL or abnormal digital examination findings were selected. The patients were randomized through random method. Group 1: patients were administered 5 mL of 2% lidocaine; group 2: patients were administered 5 mL of 25-mg tramadol; and group 3: patients were administered 5 mL of 2% lidocaine + 25-mg tramadol. The procedures were completed in 10 minutes, and a visual pain scale was administered to the patients to question the pain severity. TRUS-guided PBx was performed in 60 patients with an age range of 57-77 years (mean age, 66.2 ± 7.49 years) and a PSA range of 1-1000 ng/mL. The mean PSA level of the groups was 28.5 (±7.5), 16.1 (±5.0), and 14.9 (±2.9) ng/mL, respectively. The postprocedural pain scores by visual pain scale were 4.6 ± 1.2, 5.4 ± 1.2, and 3.6 ± 0.9 in lidocaine, tramadol, and lidocaine + tramadol groups, respectively. Periprostatic nerve block is the current golden standard method owing to pain management and comfort provided, independent of the patient age and the number of core biopsies. We suggest that tramadol may also be used in this field to achieve better pain management by improving lidocaine's effect or as an alternative to lidocaine. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Protocol for the realization of transrectal prostatic biopsy guided by ultrasound

    International Nuclear Information System (INIS)

    Arce Montero, Jairo

    2013-01-01

    A general protocol is proposed for the realization of the ultrasound-guided prostatic biopsy in patients with positive screening. The screening should be performed taking into account risk antecedents, rectal examination and prostate-specific antigen (PSA) levels in the patients. However, patients that have presented without alteration in the PSA and suspect rectal examination, should be considered for biopsy endorectal with ultrasound guidance even more with positive risk factors. The generalities of prostate cancer are described. The general prostatic anatomy and echographic are reviewed. The echographic technique is analyzed in the exploration endorectal. The echographic findings suspects of prostate cancer are characterized. The different biopsy sampling techniques are described; and based on appropriate knowledge of prostatic echographic anatomy, could increase the effectiveness in the early detection of prostate cancer in patients with positive screening. The complications derived from the process are enumerated. The final recommendations are noted on the protocol described [es

  18. Safe surgery: how accurate are we at predicting intra-operative blood loss?

    LENUS (Irish Health Repository)

    2012-02-01

    Introduction Preoperative estimation of intra-operative blood loss by both anaesthetist and operating surgeon is a criterion of the World Health Organization\\'s surgical safety checklist. The checklist requires specific preoperative planning when anticipated blood loss is greater than 500 mL. The aim of this study was to assess the accuracy of surgeons and anaesthetists at predicting intra-operative blood loss. Methods A 6-week prospective study of intermediate and major operations in an academic medical centre was performed. An independent observer interviewed surgical and anaesthetic consultants and registrars, preoperatively asking each to predict expected blood loss in millilitre. Intra-operative blood loss was measured and compared with these predictions. Parameters including the use of anticoagulation and anti-platelet therapy as well as intra-operative hypothermia and hypotension were recorded. Results One hundred sixty-eight operations were included in the study, including 142 elective and 26 emergency operations. Blood loss was predicted to within 500 mL of measured blood loss in 89% of cases. Consultant surgeons tended to underestimate blood loss, doing so in 43% of all cases, while consultant anaesthetists were more likely to overestimate (60% of all operations). Twelve patients (7%) had underestimation of blood loss of more than 500 mL by both surgeon and anaesthetist. Thirty per cent (n = 6\\/20) of patients requiring transfusion of a blood product within 24 hours of surgery had blood loss underestimated by more than 500 mL by both surgeon and anaesthetist. There was no significant difference in prediction between patients on anti-platelet or anticoagulation therapy preoperatively and those not on the said therapies. Conclusion Predicted intra-operative blood loss was within 500 mL of measured blood loss in 89% of operations. In 30% of patients who ultimately receive a blood transfusion, both the surgeon and anaesthetist significantly underestimate

  19. What is the optimal management of an intra-operative air leak in a colorectal anastomosis?

    Science.gov (United States)

    Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R

    2018-02-01

    An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  20. On the reproducibility of expert-operated and robotic ultrasound acquisitions.

    Science.gov (United States)

    Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir

    2017-06-01

    We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

  1. Analysis of intra-fraction prostate motion and derivation of duration-dependent margins for radiotherapy using real-time 4D ultrasound

    Directory of Open Access Journals (Sweden)

    Eric Pei Ping Pang

    2018-01-01

    Full Text Available Background and purpose: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. Material and methods: A four-dimension (4D transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT treatment (an additional seven minutes. A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. Results: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm and posterior (−0.2 versus −0.4 mm directions respectively (p ≪ 0.01. An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior; 0.8 mm (left/right, 1.7 mm/2.9 mm (anterior/posterior for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior, 1.5 mm (left/right, 2.8 mm/4.8 mm (anterior/posterior for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1–1.9 mm anteriorly/posteriorly. Conclusions: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should

  2. A novel ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  3. Intra-operative application of optical coherence tomography with an operating microscope.

    Science.gov (United States)

    Just, T; Lankenau, E; Hüttmann, G; Pau, H W

    2009-09-01

    To introduce the use of optical coherence tomography with an operating microscope for intra-operative evaluation of the human larynx. A specially equipped operating microscope with integrated spectral domain optical coherence tomography apparatus was used during microlaryngoscopy. Technical improvements in optical coherence tomography equipment (e.g. pilot beam, variable focal distance, improved image quality and integration into an operating microscope) have enabled greater sensitivity and imaging speed and a non-contact approach. Spectral domain optical coherence tomography now enables a better correlation between optical coherence tomography images and histological findings. With this new technology, the precision of biopsy can be improved during microlaryngoscopy. Use of this new optical coherence tomography technology, integrated into an operating microscope, enables the surgeon to define the biopsy site location and resection plane precisely, while the optical zoom of the operating microscope can be used over the complete range.

  4. [Identification and management of intra-operative suspicious tissues in 20 transsphenoidal surgery cases].

    Science.gov (United States)

    Liu, Jun-Feng; Ke, Chang-Shu; Chen, Xi; Xu, Yu; Zhang, Hua-Qiu; Chen, Juan; Gan, Chao; Li, Chao-Xi; Lei, Ting

    2013-05-01

    To determine appropriate protocols for the identification and management of intra operative suspicious tissues during transsphenoidal surgery. Clinical data and pathological reports of 20 patients with intra-operative suspicious tissues during transsphenoidal surgeries were analyzed retrospectively. The methods for discriminating between adenoma and normal pituitary tissues were reviewed. The postoperative pathological reports revealed that adenoma and normal pituitary tissues coexisted in 9 samples, while 5 samples were identified as normal pituitary tissues, 2 as adenoma tissues, and 4 as other tissues. Adenomas were distinguished from normal pituitary tissues on the basis of intra-operative appearance, texture, blood supply and possible existence of boundary. If decisions are difficult to made during surgeries from the appearance of the suspicious tissues, pathological examinations are advised as a guidance for the next steps.

  5. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    Science.gov (United States)

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  6. Intra-biliary contrast-enhanced ultrasound for evaluating biliary obstruction during percutaneous transhepatic biliary drainage: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Er-jiao [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Su, Zhong-zhen; Li, Kai; Ren, Jie; Guo, Huan-yi [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China)

    2012-12-15

    Objectives: The aimed of this study was to investigate the value of intra-biliary contrast-enhanced ultrasound (IB-CEUS) for evaluating biliary obstruction during percutaneous transhepatic biliary drainage (PTBD). Materials and methods: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison. Results: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P < 0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80). Conclusion: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.

  7. Appropriateness of Intra-Operative Blood Transfusion In Children at ...

    African Journals Online (AJOL)

    Background: The decision to transfuse intra-operatively is based on preoperative haemoglobin (Hb), estimated blood loss and physiological variables. The visual estimate of blood loss is notoriously unreliable especially with small volumes of blood losses in children. Objectives :We sought therefore to determine the ...

  8. The use of ultrasound to diagnose hepatic steatosis in type 2 diabetes: Intra- and interobserver variability and comparison with magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Williamson, R.M.; Perry, E.; Glancy, S.; Marshall, I.; Gray, C.; Nee, L.D.; Hayes, P.C.; Forbes, S.; Frier, B.M.; Johnston, G.I.; Lee, A.J.; Reynolds, R.M.; Price, J.F.; Strachan, M.W.J.

    2011-01-01

    Aim: To compare ultrasound gradings of steatosis with fat fraction (FF) on magnetic resonance spectroscopy (MRS; the non-invasive reference standard for quantification of hepatic steatosis), and evaluate inter- and intraobserver variability in the ultrasound gradings. Materials and methods: Triple grading of hepatic ultrasound examination was performed by three independent graders on 131 people with type 2 diabetes. The stored images of 60 of these individuals were assessed twice by each grader on separate occasions. Fifty-eight patients were pre-selected on the basis of ultrasound grading (normal, indeterminate/mild steatosis, or severe steatosis) to undergo 1 H-MRS. The sensitivity and specificity of the ultrasound gradings were determined with reference to MRS data, using two cut-offs of FF to define steatosis, ≥9% and ≥6.1%. Results: Median (intraquartile range) MRS FF (%) in the participants graded on ultrasound as normal, indeterminate/mild steatosis, and severe steatosis were 4.2 (1.2-5.7), 4.1 (3.1-8.5) and 19.4 (12.9-27.5), respectively. Using a liver FF of ≥6.1% on MRS to denote hepatic steatosis, the unadjusted sensitivity and specificity of ultrasound gradings (severe versus other grades of steatosis) were 71 and 100%, respectively. Interobserver agreement within one grade was observed in 79% of cases. Exact intraobserver agreement ranged from 62 to 87%. Conclusion: Hepatic ultrasound provided a good measure of the presence of significant hepatic steatosis with good intra- and interobserver agreement. The grading of a mildly steatotic liver was less secure and, in particular, there was considerable overlap in hepatic FF with those who had a normal liver on ultrasound.

  9. The use of ultrasound to diagnose hepatic steatosis in type 2 diabetes: Intra- and interobserver variability and comparison with magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, R.M., E-mail: rachel_m_williamson@hotmail.co [Metabolic Unit, Western General Hospital, Edinburgh (United Kingdom); Perry, E.; Glancy, S. [Department of Radiology, Western General Hospital, Edinburgh (United Kingdom); Marshall, I. [Scottish Funding Council Brain Imaging Research Centre, Western General Hospital, Edinburgh (United Kingdom); Gray, C. [Wellcome Trust Clinical Research Facility, Western General Hospital, Edinburgh (United Kingdom); Nee, L.D. [Department of Radiology, Western General Hospital, Edinburgh (United Kingdom); Hayes, P.C. [Department of Hepatology, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Forbes, S. [Endocrinology Unit, University of Edinburgh, Queen' s Medical Research Institute, Edinburgh (United Kingdom); Frier, B.M. [Department of Diabetes, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Johnston, G.I. [Pfizer Global R and D, Sandwich, Kent (United Kingdom); Lee, A.J. [Centre of Academic Primary Care, University of Aberdeen, Aberdeen (United Kingdom); Reynolds, R.M. [Endocrinology Unit, University of Edinburgh, Queen' s Medical Research Institute, Edinburgh (United Kingdom); Price, J.F. [Centre for Population Health Sciences, University of Edinburgh, Queen' s Medical Research Institute, Edinburgh (United Kingdom); Strachan, M.W.J. [Metabolic Unit, Western General Hospital, Edinburgh (United Kingdom)

    2011-05-15

    Aim: To compare ultrasound gradings of steatosis with fat fraction (FF) on magnetic resonance spectroscopy (MRS; the non-invasive reference standard for quantification of hepatic steatosis), and evaluate inter- and intraobserver variability in the ultrasound gradings. Materials and methods: Triple grading of hepatic ultrasound examination was performed by three independent graders on 131 people with type 2 diabetes. The stored images of 60 of these individuals were assessed twice by each grader on separate occasions. Fifty-eight patients were pre-selected on the basis of ultrasound grading (normal, indeterminate/mild steatosis, or severe steatosis) to undergo {sup 1}H-MRS. The sensitivity and specificity of the ultrasound gradings were determined with reference to MRS data, using two cut-offs of FF to define steatosis, {>=}9% and {>=}6.1%. Results: Median (intraquartile range) MRS FF (%) in the participants graded on ultrasound as normal, indeterminate/mild steatosis, and severe steatosis were 4.2 (1.2-5.7), 4.1 (3.1-8.5) and 19.4 (12.9-27.5), respectively. Using a liver FF of {>=}6.1% on MRS to denote hepatic steatosis, the unadjusted sensitivity and specificity of ultrasound gradings (severe versus other grades of steatosis) were 71 and 100%, respectively. Interobserver agreement within one grade was observed in 79% of cases. Exact intraobserver agreement ranged from 62 to 87%. Conclusion: Hepatic ultrasound provided a good measure of the presence of significant hepatic steatosis with good intra- and interobserver agreement. The grading of a mildly steatotic liver was less secure and, in particular, there was considerable overlap in hepatic FF with those who had a normal liver on ultrasound.

  10. A CT-ultrasound-coregistered augmented reality enhanced image-guided surgery system and its preliminary study on brain-shift estimation

    International Nuclear Information System (INIS)

    Huang, C H; Hsieh, C H; Lee, J D; Huang, W C; Lee, S T; Wu, C T; Sun, Y N; Wu, Y T

    2012-01-01

    With the combined view on the physical space and the medical imaging data, augmented reality (AR) visualization can provide perceptive advantages during image-guided surgery (IGS). However, the imaging data are usually captured before surgery and might be different from the up-to-date one due to natural shift of soft tissues. This study presents an AR-enhanced IGS system which is capable to correct the movement of soft tissues from the pre-operative CT images by using intra-operative ultrasound images. First, with reconstructing 2-D free-hand ultrasound images to 3-D volume data, the system applies a Mutual-Information based registration algorithm to estimate the deformation between pre-operative and intra-operative ultrasound images. The estimated deformation transform describes the movement of soft tissues and is then applied to the pre-operative CT images which provide high-resolution anatomical information. As a result, the system thus displays the fusion of the corrected CT images or the real-time 2-D ultrasound images with the patient in the physical space through a head mounted display device, providing an immersive augmented-reality environment. For the performance validation of the proposed system, a brain phantom was utilized to simulate brain-shift scenario. Experimental results reveal that when the shift of an artificial tumor is from 5mm ∼ 12mm, the correction rates can be improved from 32% ∼ 45% to 87% ∼ 95% by using the proposed system.

  11. Qualitative ultrasound elastography assessment of benign thyroid nodules: Patterns and intra-observer acquisition variability

    International Nuclear Information System (INIS)

    Lacout, Alexis; Chevenet, Carole; Thariat, Juliette; Figl, Andrea; Marcy, Pierre-Yves

    2013-01-01

    To report and evaluate qualitative elastography patterns by using gray-scale and Doppler ultrasound (US) in patients presenting with benign thyroid nodules and to evaluate the reproducibility of US elastography examinations. Institutional review board approval was obtained, and all patients provided informed consent. Over a 3-month time period, all consecutive adult patients were referred to our institution to undergo a thyroid nodule fine-needle aspiration biopsy (FNAB) procedure. Patients presenting with benign cytology according to the Bethesda 2008 classification were prospectively enrolled in the study. Each thyroid nodule was assessed by using gray-scale, Doppler US, and elastography acquisitions by a single operator (A. L.). Multiple elastography acquisitions per thyroid nodule were performed and elastography scorings of the nodules were compared with each other. Nineteen patients (16 women and 3 men, mean age 58 years) with 22 thyroid nodules were included in the present study. Elastographic patterns 1, 2, and 3 were reported (23% nodules showed pattern 3). The elastography pattern showed a strong variability in 13 nodules (59%). The elastography acquisition result variability involved the “malignant” pattern 3 in 36% of cases. Almost one-third of benign thyroid nodules displayed pattern 3 on qualitative US elastography. The intra-observer variability of the benign thyroid elastography scoring is wide, thus limiting the thyroid nodule US examination accuracy. In FNAB-proven benign thyroid nodules, elastography pattern 3 is frequent and cannot be used as a strong indicator of thyroid malignancy

  12. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

    Science.gov (United States)

    Hambright, D; Hellman, M; Barrack, R

    2018-01-01

    The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36-43. ©2018 The British Editorial Society of Bone & Joint Surgery.

  13. Impact of intra-operative intraperitoneal chemotherapy on organ/space surgical site infection in patients with gastric cancer.

    Science.gov (United States)

    Liu, X; Duan, X; Xu, J; Jin, Q; Chen, F; Wang, P; Yang, Y; Tang, X

    2015-11-01

    Various risk factors for surgical site infection (SSI) have been identified such as age, overweight, duration of surgery, blood loss, etc. Intraperitoneal chemotherapy during surgery is a common procedure in patients with gastric cancer, yet its impact on SSI has not been evaluated. To evaluate whether intra-operative intraperitoneal chemotherapy is a key risk factor for organ/space SSI in patients with gastric cancer. All patients with gastric cancer who underwent surgery at the Department of Gastrointestinal Surgery between January 2008 and December 2013 were studied. The organ/space SSI rates were compared between patients who received intra-operative intraperitoneal chemotherapy and patients who did not receive intra-operative intraperitoneal chemotherapy, and the risk factors for organ/space SSI were analysed by univariate and multi-variate regression analyses. The microbial causes of organ/space SSI were also identified. Of the eligible 845 patients, 356 received intra-operative intraperitoneal chemotherapy, and the organ/space SSI rate was higher in these patients compared with patients who did not receive intra-operative intraperitoneal chemotherapy (9.01% vs 3.88%; P = 0.002). Univariate analysis confirmed the significance of this finding (odds ratio 2.443; P = 0.003). As a result, hospital stay was increased in patients who received intra-operative intraperitoneal chemotherapy {mean 20.91 days [95% confidence interval (CI) 19.76-22.06] vs 29.72 days (95% CI 25.46-33.99); P = 0.000}. The results also suggested that intra-operative intraperitoneal chemotherapy may be associated with more Gram-negative bacterial infections. Intra-operative intraperitoneal chemotherapy is a significant risk factor for organ/space SSI in patients with gastric cancer. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. The OMERACT ultrasound task force--status and perspectives

    DEFF Research Database (Denmark)

    Naredo, Esperanza; Wakefield, Richard J; Iagnocco, Annamaria

    2011-01-01

    - and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing......This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability...... of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra...

  15. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  16. Ultrasound Imaging of the Pelvic Floor: linking anatomical findings with clinical symtoms

    OpenAIRE

    Steensma, Anneke

    2009-01-01

    textabstractFor evaluation of pelvic floor and lower urinary tract dysfunction the use of transabdominal ultrasound was first documented in the early eighties, with the translabial [1], transrectal [2] and transvaginal [3, 4] techniques developing somewhat later. To obtain a translabial or transperineal image of the pelvic floor, the transducer (ideally a 3.5-6 MHZ curved array abdominal probe) is placed on the perineum, after covering the transducer with an unpowered glove or thin plastic wr...

  17. Role of imprint cytology in intra operative diagnosis of thyroid lesions.

    Science.gov (United States)

    Anila, K R; Krishna, G

    2014-07-01

    Intra-operative imprint cytology is an important diagnostic modality in the diagnosis of thyroid lesions. A correct intra-operative diagnosis helps eliminate the need for second surgery. To study diagnostic accuracy of imprint cytology and to compare the imprint cytology results with that of the corresponding paraffin section diagnosis in thyroidectomy cases. This is a prospective study of 84 patients who have undergone thyroidectomies over a period of one year at the Department of Surgery, Thiruvananthapuram, Kerala, India. The intraoperative imprint cytology smears were stained by Papanicolaou method. The imprint cytology interpretation was later compared with the paraffin section diagnosis. Of the 84 patients using haematoxylin and eosin stained histopathology sections as the gold standard, the diagnostic sensitivity of imprint cytology was 75% and specificity was 100%. Positive predictive value was 100%. Negative predictive value was 98.74%. Imprint cytology has high sensitivity and specificity in diagnosing lesions of the thyroid. The problems faced were in diagnosing follicular carcinomas and differentiating low grade lymphoma from lymphocytic thyroiditis. Imprint cytology is a simple, reliable diagnostic technique. It has high sensitivity and specificity in intra-operative diagnosis of lesions of thyroid. In spite of the advent of newer diagnostic modalities like frozen sections, imprint cytology still holds its unique position in the current perspective.

  18. Symposium: evidence for the use of intra-articular cortisone or hyaluronic acid injection in the hip

    Science.gov (United States)

    Chandrasekaran, Sivashankar; Lodhia, Parth; Suarez-Ahedo, Carlos; Vemula, S. Pavan; Martin, Timothy J.; Domb, Benjamin G.

    2016-01-01

    The primary purpose of this review article is to discuss the role of diagnostic, corticosteroid, hyaluronic acid (HA) and platelet rich plasma (PRP) in the treatment of osteoarthritis (OA) and femoroacetabular impingement (FIA). These treatments play an important biological role in the non-operative management of these conditions. Two independent reviewers performed an search of PubMed for articles that contained at least one of the following search terms pertaining to intra-articular hip injection—local anaesthetic, diagnostic, ultrasound, fluoroscopic, image guided, corticosteroid, HA, PRP, OA, labral tears and FAI. Seventy-two full text articles were suitable for inclusion. There were 18 articles addressing the efficacy of diagnostic intra-articular hip injections. With respect to efficacy in OA there were 25 articles pertaining to efficacy of corticosteroid, 22 of HA and 4 of PRP. There were three articles addressing the efficacy of biologics in FAI. Diagnostic intra-articular hip injections are sensitive and specific for differentiating between intra-articular, extra-articular and spinal causes of hip symptoms. Ultrasound and fluoroscopy improves the precision of intra-articular positioning of diagnostic injections. Corticosteroids are more effective than HA and PRP in alleviating pain from hip OA. A higher dose of corticosteroids produces a longer benefit but volume of injection has no significant effect. Intra-articular corticosteroids do not increase infection rates of subsequent arthroplasty. There is currently limited evidence to warrant the routine use of therapeutic injections in the management of labral tears and FIA. PMID:27026814

  19. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  20. Comparative Study Of Intra-Operative Pelvimetry With Calipers And ...

    African Journals Online (AJOL)

    The pelvic measurement of patients who have had a caesarean section was done using Pelvic Calipers (intra-operative) and x-ray methods. In the former method, during Caesarean sections and after closure of the lower uterine segment incision, a pair of pelvic calipers was used to measure the true conjugate of the pelvis.

  1. Diagnostic Accuracy of Secondary Ultrasound Exam in Blunt Abdominal Trauma

    International Nuclear Information System (INIS)

    Rajabzadeh Kanafi, Alireza; Giti, Masoumeh; Gharavi, Mohammad Hossein; Alizadeh, Ahmad; Pourghorban, Ramin; Shekarchi, Babak

    2014-01-01

    In stable patients with blunt abdominal trauma, accurate diagnosis of visceral injuries is crucial. To determine whether repeating ultrasound exam will increase the sensitivity of focused abdominal sonography for trauma (FAST) through revealing additional free intraperitoneal fluid in patients with blunt abdominal trauma. We performed a prospective observational study by performing primary and secondary ultrasound exams in blunt abdominal trauma patients. All ultrasound exams were performed by four radiology residents who had the experience of more than 400 FAST exams. Five routine intraperitoneal spaces as well as the interloop space were examined by ultrasound in order to find free fluid. All patients who expired or were transferred to the operating room before the second exam were excluded from the study. All positive ultrasound results were compared with intra-operative and computed tomography (CT) findings and/or the clinical status of the patients. Primary ultrasound was performed in 372 patients; 61 of them did not undergo secondary ultrasound exam; thus, were excluded from the study.Three hundred eleven patients underwent both primary and secondary ultrasound exams. One hundred and two of all patients were evaluated by contrast enhanced CT scan and 31 underwent laparotomy. The sensitivity of ultrasound exam in detecting intraperitoneal fluid significantly increased from 70.7% for the primary exam to 92.7% for the secondary exam. Examining the interloop space significantly improved the sensitivity of ultrasonography in both primary (from 36.6% to 70.7%) and secondary (from 65.9% to 92.7%) exams. Performing a secondary ultrasound exam in stable blunt abdominal trauma patients and adding interloop space scan to the routine FAST exam significantly increases the sensitivity of ultrasound in detecting intraperitoneal free fluid

  2. Studies on the reliability of high-field intra-operative MRI in brain glioma resection

    Directory of Open Access Journals (Sweden)

    Zhi-jun SONG

    2011-07-01

    Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.

  3. The value of the intra-operative clinical mechanical axis measurement in open-wedge valgus high tibial osteotomies

    NARCIS (Netherlands)

    van de Pol, G.J.; Verdonschot, Nicolaas Jacobus Joseph; van Kampen, A.

    2012-01-01

    Introduction: In high tibial osteotomies (HTO) the correction needs to be precise and intra-operative assessment is essential. The purpose of this study was to evaluate the use of the intra-operative clinical mechanical axis measurement and compare it to the post-operative weight bearing situation

  4. Intra-operative maternal complications of emergency cesarean section done in advanced labor

    International Nuclear Information System (INIS)

    Nisa, M.U.

    2013-01-01

    Background: Emergency cesarean section done in advanced labor is a big challenge in obstetrics due to increased risk of intraoperative complications. In the last decade, a rapid increase in cesarean section done in advanced labor has been observed. Difficult deli-very of the fetal head during cesarean section carries a high risk of intraoperative complications like cervical and uterine tears, intra operative hemorrhage and trauma to the baby. Objectives: The purpose of this study is to find out the frequency and risk factors for intra-operative complications in emergency cesarean section done in advanced labor, so that appropriate management protocols can be planned to reduce these complications. Study Design: Prospective cohort study. Materials and Methods: This prospective study was carried out in Obstetrics and Gynecology Unit - 2 of Services Institute of Medical Sciences, Services Hospital, Lahore; from 1st January 2007 to 31st December 2007. All patients undergoing emergency cesarean sections done on laboring mothers were included in the study. The sample was divided into two groups; emergency C-section done in advanced labor as the study group and emergency C-section in early labor as the control group. Data were collected regarding age, parity, booked or unbooked status, indications for cesarean section, level of competence of operating surgeon, intra-operative complications and the risk factors for these complications. Data were recorded on a structured proforma and compared between the two groups. Statistical Analysis: Data were analyzed using computer programme SPSS Version 14 for windows applying student t-test for quantitative and chai square test for qualitative parameters. A p-value < 0.05 was used as statistically significant. Results: Out of 2064 total deliveries in the year 2007, 1290 (62.5%) were vaginal deliveries and 774 (37.5%) were C-Sections. Out of 774 C-Section, 174 (23%) were elective and 600 (77%) were emergency. Out of 600 emergency C

  5. Catheter placement via the occipital artery to achieve superselective intra-arterial chemotherapy for oral cancer

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2008-01-01

    Superselective intra-arterial chemotherapy via the superficial temporal artery (STA) has become useful for oral cancer. However, this method can not be performed if catheter placement via the STA is impossible. Therefore, we report a surgical method for catheter placement via the occipital artery (OA) to achieve retrograde superselective intra-arterial chemotherapy. Preoperatively, three-dimensional computed tomography angiography was performed to identify the course of the external carotid artery and the relationship between OA and the target artery. Ten patients with oral cancer underwent catheter placement via the OA with Doppler ultrasound and Harmonic Scalpel under local anesthesia. Catheter placement via the OA was superselectively successful in all the patients. The mean exposure time of OA and mean operating time were 17.5 min and 70.5 min, respectively. Catheter placement via the OA is useful when catheter placement via the STA is impossible. Three-dimensional vascular mapping and the use of Doppler ultrasound and Harmonic Scalpel can shorten the surgical time. (author)

  6. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  7. Pre-operative Duplex Ultrasonography in Arteriovenous Fistula Creation: Intra- and Inter-observer Agreement.

    Science.gov (United States)

    Zonnebeld, Niek; Maas, Tommy M G; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-11-01

    Although clinical guidelines on arteriovenous fistula (AVF) creation advocate minimum luminal arterial and venous diameters, assessed by duplex ultrasonography (DUS), the clinical value of routine DUS examination is under debate. DUS might be an insufficiently repeatable and/or reproducible imaging modality because of its operator dependency. The present study aimed to assess intra- and inter-observer agreement of DUS examination in support of AVF surgery planning. Ten end stage renal disease patients were included, to assess intra- and inter-observer agreement of pre-operative DUS measurements. All measurements were performed by two trained and experienced vascular technicians, blinded to measurement readings. From the routine DUS protocol, representative measurements (venous diameters, and arterial diameters and volume flow in the upper arm and forearm) were selected. For intra-observer agreement the measurements were performed in triplicate, with the probe released from the skin between each. Intraclass correlation coefficients were calculated for intra- and inter-observer agreement, and Bland-Altman plots used to graphically display mean measurement differences and limits of agreement. Ten patients (6 male, 59.4±19.7 years) consented to participate, and all predefined measurements were obtained. Intraclass correlation coefficients for intra-observer agreement of diameter measurements were at least 0.90 (95% CI 0.74-0.97; radial artery). Inter-observer agreement was at least 0.83 (0.46-0.96; lateral diameter upper arm cephalic vein). The Bland-Altman plots showed acceptable mean measurement differences and limits of agreement. In experienced hands, excellent intra- and inter-observer agreement can be reached for the discrete pre-operative DUS measurements advocated in clinical guidelines. DUS is therefore a reliable imaging modality to support AVF surgery planning. The content of DUS protocols, however, needs further standardisation. Copyright © 2017 European

  8. Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy.

    Science.gov (United States)

    Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M

    2018-01-01

    Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.

  9. The OMERACT ultrasound task force--status and perspectives.

    LENUS (Irish Health Repository)

    Naredo, Esperanza

    2011-09-01

    This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA.

  10. Ultrasonographic-arthroscopic correlation in knee injuries in patients operated on at the Hospital Mexico, during the period from January 1, 2010 until December 31, 2010

    International Nuclear Information System (INIS)

    Zamora Lopez, Rafael Angel

    2012-01-01

    Ultrasound is evaluated as a method of diagnosis for intra-articular pathologies of knee, widely used as a means to rule out injuries to the institutional level. The advantages of ultrasound are mentioned: low cost, availability and is a noninvasive method. In order to implement this study has been to create a question about the real utility of ultrasound in the Hospital Mexico, as further support for the correct diagnosis of knee pathology. A search of clinical records of patients was conducted in the orthopedics and traumatology service with diagnosis of gonalgia, to which was conducted a preoperative ultrasound and, subsequently, have been operated at the Hospital by arthroscopy, during the period 1 January 2010 to December 31, 2010. Subsequently, a comprehensive review of the operative notes was performed, ultrasound reports and records, for the purpose of making an analysis and compare the results of both procedures. This paper has clearly demonstrated poor training in musculoskeletal system of the ultrasound operators. A poor correlation was determined between the arthroscopic results against ultrasound. The need to create care protocols to patients with intra-articular pathology of knee was evidenced. (author) [es

  11. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    Science.gov (United States)

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  12. Transrectal ultrasonographic evaluation of combined utero-placental thickness during the last half of pregnancy in Martina Franca donkeys.

    Science.gov (United States)

    Carluccio, A; Noto, F; Parrillo, S; Contri, A; De Amicis, I; Gloria, A; Robbe, D; Veronesi, M C

    2016-12-01

    In the recent years, the donkey population decreased dramatically so that many breeds are presently considered as endangered. In comparison to the horse, the donkey placenta still remains not completely studied. In the horse, one of the diagnostic tools useful to identify pregnant mares at risk of abortion or premature delivery, include the transrectal ultrasound examination of the uterus and its contents; and especially of the combined thickness of the uterus and of the placenta (CUPT). Since the CUPT was never investigated in donkeys, the present study was aimed to define the transrectal CUPT values during the last half of pregnancy in 20 Martina Franca jennies. Foalings times, foals characteristics and placental gross appearance, and measurements were also evaluated and values resulted always within normality. Differently to the mare, a continuous significant CUPT increase between the sixth to the 12 months of pregnancy, and a substantial increase from the ninth to the 12th month of pregnancy, was found. Although statistically not evaluable, the CUPT values recorded from three jennies with pregnancy loss did not show evidence of CUPT increases. In conclusion, normal CUPT values from the sixth to the 12th month of pregnancy in Martina Franca donkeys are provided, but further investigations are needed to define possible breed or body-size CUPT specific differences, as well as the CUPT values during pregnancy disturbances or placental abnormalities. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Fenster, Aaron; Ward, Aaron D

    2018-03-01

    Magnetic resonance imaging (MRI)-targeted, three-dimensional (3D) transrectal ultrasound (TRUS)-guided prostate biopsy aims to reduce the 21-47% false-negative rate of clinical two-dimensional (2D) TRUS-guided systematic biopsy, but continues to yield false-negative results. This may be improved via needle target optimization, accounting for guidance system errors and image registration errors. As an initial step toward the goal of optimized prostate biopsy targeting, we investigated how needle delivery error impacts tumor sampling probability for two targeting strategies. We obtained MRI and 3D TRUS images from 49 patients. A radiologist and radiology resident assessed these MR images and contoured 81 suspicious regions, yielding tumor surfaces that were registered to 3D TRUS. The biopsy system's root-mean-squared needle delivery error (RMSE) and systematic error were modeled using an isotropic 3D Gaussian distribution. We investigated two different prostate tumor-targeting strategies using (a) the tumor's centroid and (b) a ring in the lateral-elevational plane. For each simulation, targets were spaced at equal arc lengths on a ring with radius equal to the systematic error magnitude. A total of 1000 biopsy simulations were conducted for each tumor, with RMSE and systematic error magnitudes ranging from 1 to 6 mm. The difference in median tumor sampling probability and probability of obtaining a 50% core involvement was determined for ring vs centroid targeting. Our simulation results indicate that ring targeting outperformed centroid targeting in situations where systematic error exceeds RMSE. In these instances, we observed statistically significant differences showing 1-32% improvement in sampling probability due to ring targeting. Likewise, we observed statistically significant differences showing 1-39% improvement in 50% core involvement probability due to ring targeting. Our results suggest that the optimal targeting scheme for prostate biopsy depends on

  14. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    International Nuclear Information System (INIS)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J.

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome

  15. Ultrasound-guided endocavitary drainage of pelvic abscesses: Technique, results and complications

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, R.S.; McGrath, F P.; Haslam, P.J.; Varghese, J.C.; Lee, M.J

    2003-01-01

    AIM: To evaluate the experience in our institution with ultrasound-guided transrectal and transvaginal (endocavitary) drainage of pelvic abscesses. MATERIALS AND METHODS: Eighteen patients (four male, 14 female; mean age 55 years, range 30-78 years) presenting with pelvic abscesses were referred to our institution for therapeutic drainage over a 4 year period. Patients received broad-spectrum antibiotics prior to drainage, which was performed by either the transvaginal or transrectal route under ultrasound guidance. Patients were given sedo-analgesia in the form of midazolam and fentanyl and local anaesthesia was also employed. Eight French catheters were inserted into the abscess cavities, and patients were subsequently monitored on a daily basis by a member of the interventional radiology team until such time as it was deemed appropriate to remove the catheter. RESULTS: Eighteen catheters were placed in 17 patients, and transvaginal aspiration alone was performed in one patient. Drainage was successful in 16 of 17 patients, but a transgluteal approach was ultimately required in the remaining patient to enable passage of a larger catheter into an infected haematoma. The mean duration of drainage was 5 days, mean time to defervesce 2 days. Spontaneous catheter dislodgement occurred in four patients associated with straining, but this did not have any adverse effect in three of the four patients. CONCLUSION: Endocavitary drainage is an effective method of treatment for pelvic abscesses. Spontaneous catheter dislodgement does not affect patient outcome.

  16. The ultrastructure of tumor cells in patients with rectal cancer after pre-operative irradiation and intra-operative cryotherapy

    International Nuclear Information System (INIS)

    Vyinnik, Yu.O.; Kotenko, O.Je.; Nevzorov, V.P.; Chyibyisov, L.P.

    2000-01-01

    Electronic microscopy of the tumor cells was performed to confirm the efficacy of combined pre-operative gamma-therapy and intraoperative cryotherapy (CT). Pre-operative irradiation at the dose of 20 Gy accompanied by intra-operative cryotherapy caused the changes in the ultrastructure, the depth and degree of which allow to consider them destructive and irreversible

  17. Prostatic carcinoma. Diagnostic and stating: MR imaging. Cancer de la prostate Diagnostic et bilan: role de l'imagerie

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C; Spittler, G; Jacqmin, D [Centre Hospitalier Universitaire, 67 - Strasbourg (FR); Morel, M [Clinique Saint-Francois, 67 Haguenau (FR)

    1991-01-01

    Prostatic carcinoma is the second most commun cause of cancer death over 60 years. It is suspected by digital examination and prostatic specific antigen dosage. Transrectal ultrasound shows the tumor as an hypoechoic lesion. Sensitivity is good but specificity is low. Transrectal biopsy of prostate guided by transrectal ultrasound made the diagnosis. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging of prostatic carcinoma.

  18. MO-B-BRC-02: Ultrasound Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Z. [Duke University Medical Center (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  19. MO-B-BRC-02: Ultrasound Based Prostate HDR

    International Nuclear Information System (INIS)

    Chang, Z.

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  20. Fluorocholangiography: reincarnation in the laparoscopic era-evaluation of intra-operative cholangiography in 3635 laparoscopic cholecystectomies.

    Science.gov (United States)

    Nassar, Ahmad H M; Mirza, Ahmad; Qandeel, Haitham; Ahmed, Zubir; Zino, Samer

    2016-05-01

    The introduction of laparoscopic cholecystectomy (LC) resulted in the decline of routine intra-operative cholangiography (IOC). Common bile duct stones are being diagnosed preoperatively using magnetic resonance cholangiopancreatography (MRCP). We aim to evaluate the use and benefits of IOC during laparoscopic biliary surgery at a high-volume biliary surgery unit. Prospective data from 4088 patients undergoing LC over 22 years were analysed. Referral protocols allow one firm to receive the great majority of biliary emergencies and all suspected ductal stones. All patients with gall stones on ultrasound scanning, fit for surgery, will undergo LC during the index admission. MRCP and ERCP are not part of preoperative investigation. A four-port LC is performed with a size 5Fr ureteric catheter within an open cannula to obtain an IOC through right sub-costal port. Of 4088 patients, IOC was attempted in 3691 (90.2 %) and 3635 had a successful IOC (98.4 %). 75 % were females. The mean age was 59 years. Patients presented with one or more of the following: chronic biliary pain in 60 %, acute pain 26.7 %, acute cholecystitis 8.4 %, gallstone pancreatitis 7.8 % and jaundice with or without cholangitis in 19.2 %. A total of 1328 patients (36.5 %) had risk factors for CBD stones. The IOC was abnormal in 975 cases (26.8 %), recording 1599 abnormalities. IOC identified 774 patients with CBD stones (21.3 %), including previously unsuspected CBD stones in 4.7 %. IOC was false negative in 20 cases (0.5 %) found to have stones on basket exploration. A decision not to perform IOC in 453 cases (11 %) was made preoperatively in 74.2 % and intra-operatively in 12.3 %. IOC can be safely and routinely performed in LC. It helps to identify CBD stones, even in patients with no known risk factors, delineate bile duct anatomy and facilitate single-stage management of CBD stones.

  1. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    Science.gov (United States)

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  2. Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

    International Nuclear Information System (INIS)

    Peikari, Mohammad; Chen, Thomas Kuriran; Lasso, Anras; Heffter, Tamas; Fichtinger, Gabor; Burdette, Everette C.

    2012-01-01

    Purpose: Ultrasound elevation beamwidth leads to image artifacts and uncertainties in localizing objects (such as a surgical needle) in ultrasound images. The authors examined the clinical significance of errors caused by elevation beamwidth artifacts and imaging parameters in needle insertion procedures. Methods: Beveled prostate brachytherapy needles were inserted through all holes of a grid template under real-time transrectal ultrasound (TRUS) guidance. The needle tip position as indicated by the TRUS image was compared to their observed physical location. A new device was developed to measure the ultrasound elevation beamwidth. Results: Imaging parameters of the TRUS scanner have direct impact on the localization error ranging from 0.5 up to 4 mm. The smallest localization error was observed laterally close to the center of the grid template and axially within the beam's focal zone. Largest localization error occurs laterally around both sides of the grid template and axially within the beam's far field. The authors also found that the localization errors vary with both lateral and elevation offsets. Conclusions: The authors found properly adjusting the TRUS imaging settings to lower the ultrasound gain and power effectively minimized the appearance of elevation beamwidth artifacts and in turn reduced the localization errors of the needle tip.

  3. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  4. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  5. Urethral stricture disease after bipolar prostatectomy: Is it a concern?

    African Journals Online (AJOL)

    A.A. Zamel

    2018-02-16

    Feb 16, 2018 ... and transrectal ultrasound (TRUS) for total gland and adenoma vol- ume assessment. ... Germany) bipolar high-frequency generator was used. .... incident power (even if in short bursts), and a long operation time in case of a ...

  6. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS

    NARCIS (Netherlands)

    Futterer, J.J.; Moche, M.; Busse, H.; Yakar, D.

    2016-01-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and

  7. Reverse Transrectal Stapling Technique Using the EEA Stapler: An ...

    African Journals Online (AJOL)

    Reverse Transrectal Stapling Technique Using the EEA Stapler: An Alternative Approach in Difficult Reversal of Hartmann's Procedure. SK Zachariah. Abstract. The introduction of circular end-to-end stapling devices (CEEA OR EEA stapler) into colorectal surgery have revolutionised anastomotic techniques. The EEA ...

  8. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  9. Intra-operative warming with a forced-air warmer in preventing hypothermia after tourniquet deflation in elderly patients.

    Science.gov (United States)

    Kim, Y-S; Jeon, Y-S; Lee, J-A; Park, W-K; Koh, H-S; Joo, J-D; In, J-H; Seo, K-W

    2009-01-01

    This randomized, single-blind study aimed to explore the effects of intra-operative warming with a forced-air warmer in the prevention of hypothermia after tourniquet deflation in elderly patients undergoing unilateral total knee replacement arthroplasty under general anaesthesia. Patients were randomized to receive either intra-operative warming using a forced-air warmer with an upper body blanket (warming group; n = 12) or no intra-operative warming (nonwarming group; n = 12). Oesophageal temperature was measured as core body temperature. At 30 min following tourniquet inflation, the core body temperature started to increase in the warming group whereas it continued to drop in the non-warming group. This difference was statistically significant. The final core body temperature after tourniquet deflation was significantly higher in the warming group (mean +/- SD 36.1 +/- 0.2 degrees C) than in the non-warming group (35.4 +/- 0.3 degrees C). Intra-operative forced-air warming increased the core body temperature before tourniquet deflation and prevented subsequent hypothermia in elderly patients under general anaesthesia.

  10. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M.

    2017-01-01

    interval): approximately ± 7.5 mm, Pearson's correlation R: 0.948-0.974). Navigation ultrasound can measure clavicular length with an intra-rater reliability matching that of 3-D rendered computed tomography scans and with high validity. Its use could spread to other fields requiring accurate...... of 52.5 (range: 21-78 y) were included. Navigation ultrasound exhibited high reliability (intra-class correlation coefficient: 0.942-0.997, standard error of the mean: 0.7-2.9 mm, minimal detectable change: 2.3-8.1 mm) and validity (measurement error: 1.3%-1.8%, limits of agreement (95% confidence...

  11. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    Science.gov (United States)

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  12. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  13. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    Science.gov (United States)

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  14. A Novel Stress-Diathesis Model to Predict Risk of Post-operative Delirium: Implications for Intra-operative Management

    Directory of Open Access Journals (Sweden)

    Renée El-Gabalawy

    2017-08-01

    Full Text Available Introduction: Risk assessment for post-operative delirium (POD is poorly developed. Improved metrics could greatly facilitate peri-operative care as costs associated with POD are staggering. In this preliminary study, we develop a novel stress-diathesis model based on comprehensive pre-operative psychiatric and neuropsychological testing, a blood oxygenation level-dependent (BOLD magnetic resonance imaging (MRI carbon dioxide (CO2 stress test, and high fidelity measures of intra-operative parameters that may interact facilitating POD.Methods: The study was approved by the ethics board at the University of Manitoba and registered at clinicaltrials.gov as NCT02126215. Twelve patients were studied. Pre-operative psychiatric symptom measures and neuropsychological testing preceded MRI featuring a BOLD MRI CO2 stress test whereby BOLD scans were conducted while exposing participants to a rigorously controlled CO2 stimulus. During surgery the patient had hemodynamics and end-tidal gases downloaded at 0.5 hz. Post-operatively, the presence of POD and POD severity was comprehensively assessed using the Confusion Assessment Measure –Severity (CAM-S scoring instrument on days 0 (surgery through post-operative day 5, and patients were followed up at least 1 month post-operatively.Results: Six of 12 patients had no evidence of POD (non-POD. Three patients had POD and 3 had clinically significant confusional states (referred as subthreshold POD; ST-POD (score ≥ 5/19 on the CAM-S. Average severity for delirium was 1.3 in the non-POD group, 3.2 in ST-POD, and 6.1 in POD (F-statistic = 15.4, p < 0.001. Depressive symptoms, and cognitive measures of semantic fluency and executive functioning/processing speed were significantly associated with POD. Second level analysis revealed an increased inverse BOLD responsiveness to CO2 pre-operatively in ST-POD and marked increase in the POD groups when compared to the non-POD group. An association was also noted for

  15. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  16. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-01-01

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p -2 ± 0.01 μm and 1.99 x 10 -2 ± 0.004 μm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  17. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  18. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  19. Intra-Operative Amylase Concentration in Peri-Pancreatic Fluid Predicts Pancreatic Fistula After Distal Pancreatectomy

    NARCIS (Netherlands)

    Nahm, C.B.; Reuver, P.R.; Hugh, T.J.; Pearson, A.; Gill, A.J.; Samra, J.S.; Mittal, A.

    2017-01-01

    Post-operative pancreatic fistula (POPF) is a potentially severe complication following distal pancreatectomy. The aim of this study was to assess the predictive value of intra-operative amylase concentration (IOAC) in peri-pancreatic fluid after distal pancreatectomy for the diagnosis of POPF.

  20. l-Arginine Pathway Metabolites Predict Need for Intra-operative Shunt During Carotid Endarterectomy

    DEFF Research Database (Denmark)

    Szabo, P; Lantos, J; Nagy, L

    2016-01-01

    lactate levels were increased during reperfusion (p = .02). The median pre-operative concentration of l-arginine was lower in patients requiring an intra-operative shunt than in patients without need of shunt (median: 30.3 μmol/L [interquartile range 24.4-34.4 μmol/L] vs. 57.6 μmol/L [interquartile range...

  1. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  2. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  3. Identifying the variables associated with pain during transrectal ultrasonography of the prostate

    Directory of Open Access Journals (Sweden)

    Hou CP

    2015-08-01

    allowed them to observe the real-time images during the examination.Conclusion: Although a TRUS examination is uncomfortable for patients, after having identified the factors affecting pain, physicians can assist patients in reducing pain during the procedure, thus providing higher quality examinations. Keywords: VAS, TRUS, ultrasound, pain score, transrectal, benign prostate hyperplasia, digital examination

  4. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  5. Intra-operative radiation treatment of cancers

    International Nuclear Information System (INIS)

    Dubois, J.B.; Joyeux, H.; Solassol, C.; Pujol, H.

    1986-01-01

    Intra-operative radiation treatment (I.O.R.T.) is concerning the treatment either of an unresectable tumor or of tumor bed after complete excision of a primary tumor and its first draining lymph nodes. We describe X-ray and electrons techniques and we discuss the delivered doses according to experimental and clinical data. According to the residual disease (macroscopic or microscopic), to the healthy tissues in the target volume, and the histological type, single doses from 20 Gy to 40 Gy can be delivered. Our preliminary results are reported: 25 patients with resectable tumors of the cardia, the stomach and the pancreas, 5 patients with pelvic recurrences of colon and rectum carcinomas. Therapeutic results of the I.O.R.T. providing from the literature are discussed. The I.O.R.T. indications are defined as palliative (unresectable tumors) and curative (irradiation of tumor bed after complete excision of the tumor) [fr

  6. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaete; Benedeti, Augusto Cesar Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge, E-mail: fernando@fatesa.edu.br [Faculdade de Tecnologia em Saude (FATESA), Ribeirao Preto, SP (Brazil); Universidade de Fortaleza (UNIFOR), Fortaleza, CE (Brazil). Departmento de Radiologia; Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Departmento de Medicina Clinica; Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras; Hospital Mae de Deus, Porto Alegre, RS (Brazil)

    2017-05-15

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. (author)

  7. Intra-Abdominal Hydatid Cyst: Sociodemographics, Clinical Profiles, and Outcomes of Patients Operated on at a Tertiary Hospital in Addis Ababa, Ethiopia

    Directory of Open Access Journals (Sweden)

    Engida Abebe

    2017-01-01

    Full Text Available Background. Hydatid cyst is caused by the tapeworm Echinococcus granulosus. The abdomen, specifically the liver, is the most common site affected. Objective. Determine the presentation patterns, types of surgical management, and outcomes of patients operated for intra-abdominal hydatid cyst (IAHC. Methodology. A retrospective descriptive study of patients admitted and operated for IAHC from September 1, 2011, to August 31, 2015. Results. Forty-two patients whose age ranged from 10 to 65 (mean of 37 years were operated on. Females comprised 27 (64.3% of the patients. The commonest presenting complaint was abdominal pain (41, 97.6%. Abdominal mass was documented in 23 (54.7% cases. Abdominal ultrasound (AUS and CT were the main imaging studies done on 38 (90.5% and 24 (57.1% patients, respectively. Cysts measuring more than 10 cm in diameter were the most common finding in both studies. Liver was the primary site involved, 30 (71.4% cases, the right lobe being the main side, 73%. Thirty-eight (90.5% patients underwent deroofing, evacuation, marsupialization, and omentoplasty (DEMO. There was no perioperative death, but 4 (9.5% of the patients had post-op complications. Conclusion. Abdominal pain was the most common presenting complaint. AUS and CT remain the preferred imaging. DEMO was the most common surgery.

  8. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-01

    Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

  9. Intra-operative neurophysiological mapping and monitoring during brain tumour surgery in children: an update.

    Science.gov (United States)

    Coppola, Angela; Tramontano, Vincenzo; Basaldella, Federica; Arcaro, Chiara; Squintani, Giovanna; Sala, Francesco

    2016-10-01

    Over the past decade, the reluctance to operate in eloquent brain areas has been reconsidered in the light of the advent of new peri-operative functional neuroimaging techniques and new evidence from neuro-oncology. To maximise tumour resection while minimising morbidity should be the goal of brain surgery in children as much as it is in adults, and preservation of brain functions is critical in the light of the increased survival and the expectations in terms of quality of life. Intra-operative neurophysiology is the gold standard to localise and preserve brain functions during surgery and is increasingly used in paediatric neurosurgery. Yet, the developing nervous system has peculiar characteristics in terms of anatomical and physiological maturation, and some technical aspects need to be tailored for its use in children, especially in infants. This paper will review the most recent advances in the field of intra-operative neurophysiology (ION) techniques during brain surgery, focussing on those aspects that are relevant to the paediatric neurosurgery practice.

  10. Automated 3D ultrasound measurement of the angle of progression in labor.

    Science.gov (United States)

    Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly

    2018-01-01

    To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.

  11. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  12. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  13. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    International Nuclear Information System (INIS)

    Baek, Song Ee; Oh, Young Taik; Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul

    2010-01-01

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4±1.78: group 2, 2.8±1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  14. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  15. Ultrasound guided TAP block versus ultrasound guided caudal block for pain relief in children undergoing lower abdominal surgeries

    Directory of Open Access Journals (Sweden)

    Wafaa Mohamed Alsadek

    2015-04-01

    Conclusion: TAP block and caudal block under ultrasound guidance proved to be safe with no recorded complications either intra or postoperatively. Patient and parent satisfaction was markedly observed in case of TAP block.

  16. Intra-operative 3-T MRI for paediatric brain tumours: challenges and perspectives

    International Nuclear Information System (INIS)

    Abernethy, L.J.; Avula, S.; Hughes, G.M.; Wright, E.J.; Mallucci, C.L.

    2012-01-01

    MRI is the ideal modality for imaging intracranial tumours. Intraoperative MRI (ioMRI) makes it possible to obtain scans during a neurosurgical operation that can aid complete macroscopic tumour resection - a major prognostic factor in the majority of brain tumours in children. Intra-operative MRI can also help limit damage to normal brain tissue. It therefore has the potential to improve the survival of children with brain tumours and to minimise morbidity, including neurological deficits. The use of ioMRI is also likely to reduce the need for second look surgery, and may reduce the need for chemotherapy and radiotherapy. High-field MRI systems provide better anatomical information and also enable effective utilisation of advanced MRI techniques such as perfusion imaging, diffusion tensor imaging, and magnetic resonance spectroscopy. However, high-field ioMRI facilities require substantial capital investment, and careful planning is required for optimal benefit. Safe ioMRI requires meticulous attention to detail and rigorous application of magnetic field safety precautions. Interpretation of ioMRI can be challenging and requires experience and understanding of artefacts that are common in the intra-operative setting. (orig.)

  17. Comparison of preoperative computerized tomography scan imaging of temporal bone with the intra-operative findings in patients undergoing mastiodectomy

    International Nuclear Information System (INIS)

    Gerami, H.; Naghavi, E.; Wahabi-Moghadam, M.; Forghanparast, K.; Akbar, Manzar H.

    2009-01-01

    Objective was to compare the consistency rates of pre- and intra-operative radiological findings in patients with chronic suppurative otitis media (CSOM). In a cross-sectional study, 80 patients with CSOM underwent pre-operative CT scanning and we compared the results with intra-operative clinical findings during mastiodectomy from 2000-2004 in the Otology Department, Amiralmomenin Hospital of Guilan Medical University, Rasht, Iran. Sensitivity, specificity, positive and negative predictive value of CT scan in tympanic and mastoid cholesteatoma, ossicular chain erosion, tegmentympani erosion, dehiscence of facial canal, lateral semicircular canal (LSCC) fistula were assessed. Then, correlation between radiological findings and intra-operative findings were calculated. The mean age of patients was 27.9+-16.3 years. Mostly were males (n=57 [71.3%]). Correlation of preoperative radiological images with intra-operative clinical findings were moderate to good on tympanic cholesteatoma, mastoid cholesteatoma and ossicular chain erosion, but weak and insignificant in cases of tegmen erosion, facial canal dehiscene and LSCC fistulae. Preoperative CT scan may be helpful in decision-making for surgery in cases of cholesteatoma and ossicular erosion. Despite of limitations radiological scanning is a useful adjunct to management of CSOM. (author)

  18. Intra-operative mapping of the atria: the first step towards individualization of atrial fibrillation therapy?

    Science.gov (United States)

    Kik, Charles; Mouws, Elisabeth M J P; Bogers, Ad J J C; de Groot, Natasja M S

    2017-07-01

    Atrial fibrillation (AF), an age-related progressive disease, is becoming a worldwide epidemic with a prevalence rate of 33 million. Areas covered: In this expert review, an overview of important results obtained from previous intra-operative mapping studies is provided. In addition, our novel intra-operative high resolution mapping studies, its surgical considerations and data analyses are discussed. Furthermore, the importance of high resolution mapping studies of both sinus rhythm and AF for the development of future AF therapy is underlined by our most recent results. Expert commentary: Progression of AF is determined by the extensiveness of electropathology which is defined as conduction disorders caused by structural damage of atrial tissue. The severity of electropathology is a major determinant of therapy failure. At present, we do not have any diagnostic tool to determine the degree of electropathology in the individual patient and we can thus not select the most optimal treatment modality for the individual patient. An intra-operative, high resolution scale, epicardial mapping approach combined with quantification of electrical parameters may serve as a diagnostic tool to stage AF in the individual patient and to provide patient tailored therapy.

  19. Role of routine pre-operative screening venous duplex ultrasound in morbidly obese patients undergoing bariatric surgery

    Directory of Open Access Journals (Sweden)

    P Praveen Raj

    2017-01-01

    Full Text Available Background/Aims: It is well established that obesity is a strongly associated risk factor for post-operative deep vein thrombosis (DVT. Physical effects and pro-thrombotic, pro-inflammatory and hypofibrinolytic effects of severe obesity may predispose to idiopathic DVT (pre-operatively because of which bariatric patients are routinely screened before surgery. The aim of this study was to audit the use of routine screening venous duplex ultrasound in morbidly obese patients before undergoing bariatric surgery. Methods: We retrospectively reviewed 180 patients who underwent bariatric surgery from August 2013 to August 2014 who had undergone pre-operative screening bilateral lower-extremity venous duplex ultrasound for DVT. Data were collected on patient's demographics, history of venous thromboembolism, prior surgeries and duplex ultrasound details of the status of the deep veins and superficial veins of the lower limbs. Results: No patients had symptoms or signs of DVT pre-operatively. No patient gave history of DVT. No patient was found to have iliac, femoral or popliteal vein thrombosis. Superficial venous disease was found in 17 (8%. One patient had a right lower limb venous ulcer. Conclusion: Thromboembolic problems in the morbidly obese before bariatric surgery are infrequent, and screening venous duplex ultrasound can be done in high-risk patients only.

  20. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    Science.gov (United States)

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (Pstep scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  1. Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery

    NARCIS (Netherlands)

    Knobben, BAS; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    The aim of this study was to evaluate whether behavioural and systemic measures wilt decrease intra-operative contamination during total hip or knee replacements. The influence of these measures on subsequent prolonged wound discharge, superficial surgical site infection and deep periprosthetic

  2. The effect of Kombucha on post-operative intra-abdominal adhesion formation in rats.

    Science.gov (United States)

    Maghsoudi, Hemmat; Mohammadi, Hussein Benagozar

    2009-04-01

    Peritoneal adhesions are fibrous bands of tissues formed between organs that are normally separated and/or between organs and the internal body wall after peritoneal injury. The aim of the study was to investigate the effect of intra-peritoneal administration of Kombucha on intra-peritoneal adhesions. Eighty Wistar rats were subjected to standardized lesion by scraping model and were randomly divided into two groups. Group I received no treatment, and Group II received 15 ml of Kombucha solution intra-peritoneally. On the post-operative 14th day adhesion intensity score, inflammatory cell reaction and number of adhesion bands were determined. In the control group, there were no rats with grade 0 and I adhesions. In the group II, there were 26 rats (78.8%) with grade 0-2 adhesions. Adhesion intensity was significantly less in group II (PKombucha might be useful for preventing peritoneal adhesions.

  3. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  4. Effects of management strategies on glucocorticoids and behavior in Indian rhinoceros (Rhinoceros unicornis): translocation and operant conditioning.

    Science.gov (United States)

    Capiro, Jonnie M; Stoops, Monica A; Freeman, Elizabeth W; Clawson, Dave; Schook, Mandi W

    2014-01-01

    The ex situ Indian rhino population experienced a decrease in genetic diversity indicating that the breeding program could possibly benefit from novel reproductive management strategies to ensure population sustainability. We sought to determine how management tools used for reproductive management, specifically translocation and operant conditioning, impact physiological and behavioral measures of welfare in Indian rhinos. First, an adrenocorticotropic hormone challenge performed in an adult male resulted in a 38-fold increase in urinary and a 3.5-fold increase in fecal glucocorticoid metabolites (FGM). Mean and peak FGM differed among three females, but all demonstrated elevated (P operant conditioning to stand during transrectal ultrasound exams were monitored and rhinos differed in their mean and peak FGM concentrations. However, FGM were not different before versus during training or on pasture versus in the barn. One female exhibited more stereotypic behavior during training in the barn than on pasture (P operant conditioning only resulted in minimal changes in behaviors and FGM. © 2014 Wiley Periodicals Inc.

  5. A tele-operated mobile ultrasound scanner using a light-weight robot.

    Science.gov (United States)

    Delgorge, Cécile; Courrèges, Fabien; Al Bassit, Lama; Novales, Cyril; Rosenberger, Christophe; Smith-Guerin, Natalie; Brù, Concepció; Gilabert, Rosa; Vannoni, Maurizio; Poisson, Gérard; Vieyres, Pierre

    2005-03-01

    This paper presents a new tele-operated robotic chain for real-time ultrasound image acquisition and medical diagnosis. This system has been developed in the frame of the Mobile Tele-Echography Using an Ultralight Robot European Project. A light-weight six degrees-of-freedom serial robot, with a remote center of motion, has been specially designed for this application. It holds and moves a real probe on a distant patient according to the expert gesture and permits an image acquisition using a standard ultrasound device. The combination of mechanical structure choice for the robot and dedicated control law, particularly nearby the singular configuration allows a good path following and a robotized gesture accuracy. The choice of compression techniques for image transmission enables a compromise between flow and quality. These combined approaches, for robotics and image processing, enable the medical specialist to better control the remote ultrasound probe holder system and to receive stable and good quality ultrasound images to make a diagnosis via any type of communication link from terrestrial to satellite. Clinical tests have been performed since April 2003. They used both satellite or Integrated Services Digital Network lines with a theoretical bandwidth of 384 Kb/s. They showed the tele-echography system helped to identify 66% of lesions and 83% of symptomatic pathologies.

  6. Splenectomy in a Nigerian Teaching Hospital: A comparison of sonographic correlation with intra-operative findings in trauma

    Directory of Open Access Journals (Sweden)

    Oludolapo Afuwape

    2013-01-01

    Full Text Available Background: Missed or inappropriately-treated splenic injury is a significant cause of preventable trauma-related death. Physical examination and abdominal ultrasonography are essential tools for early diagnosis of splenic injury. However, some injuries may not be accurately diagnosed by ultrasonography at initial evaluation. Aim: The aim of this study was to audit indications for splenectomy at the University College Hospital, Ibadan and to compare the intra-operative findings in trauma-related cases with the sonographic findings. Materials and Methods: We retrospectively reviewed all adult (12 years and older patients′ records who had splenectomy between July 2003 and June 2010. The data extracted included patient demographics and indications for splenectomy. In trauma cases, the mode of injury and vital signs at presentation, sonographic findings, and operation findings were recorded. The intervals between injury and sonography and duration to surgery were also noted respectively. Results: Eighty-four patients were reviewed in the 7-year review period. The male to female ratio was approximately 2:1. The ages ranged from 14 to 76 years with a peak incidence in the third decade. Elective indications for splenectomy were 14 (16.6%, while 70 (83.3% were emergency cases. Forty-four of the trauma-related patients had pre-operative abdominal ultrasound, of which 31 (70% was reported as sonographically normal prior to surgery, while the rest of the trauma-related cases were considered too ill for ultrasonography. Conclusion: Potentially significant injuries may be missed with screening sonography. For this reason, a physician must maintain a high index of suspicion and consider the patient′s clinical status or an alternative imaging modality in excluding a diagnosis of splenic injury.

  7. Effect of Low-Intensity Pulsed Ultrasound on Joint Injury and Post-Traumatic Osteoarthritis: an Animal Study.

    Science.gov (United States)

    Zahoor, Talal; Mitchell, Reed; Bhasin, Priya; Guo, Yi; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-01-01

    This study investigated the therapeutic potential of low-intensity pulsed ultrasound (LIPUS) in post-traumatic osteoarthritis (PTOA). Intra-articular fracture of the medial tibial plateau was surgically created in 30 rats. LIPUS was applied to the operated joints either for the first 2 wk (LIPUS 1-2 group) or in weeks 4 and 5 after intra-articular fracture (LIPUS 4-5 group). In controls, the operated knees were not treated with LIPUS (LIPUS 0 group). The rats were monitored with weekly gait analysis and euthanized at week 8. Among the altered gait parameters, the maximal and average paw print areas in the LIPUS 1-2 and LIPUS 4-5 groups, but not the LIPUS 0 group, had either reached baseline or significantly recovered (70%, p <0.05) by week 8. PTOA pathology in both the LIPUS 1-2 and LIPUS 4-5 groups was less severe than that in the LIPUS 0 group (Mankin score: 5.4 and 4.5 vs. 8.8, p <0.05). In conclusion, LIPUS treatment partially improved the gait of the affected limbs and reduced cartilage degeneration in PTOA. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  8. Circumferential targeted renal sympathetic nerve denervation with preservation of the renal arterial wall using intra-luminal ultrasound

    Science.gov (United States)

    Roth, Austin; Coleman, Leslie; Sakakura, Kenichi; Ladich, Elena; Virmani, Renu

    2015-03-01

    An intra-luminal ultrasound catheter system (ReCor Medical's Paradise System) has been developed to provide circumferential denervation of the renal sympathetic nerves, while preserving the renal arterial intimal and medial layers, in order to treat hypertension. The Paradise System features a cylindrical non-focused ultrasound transducer centered within a balloon that circulates cooling fluid and that outputs a uniform circumferential energy pattern designed to ablate tissues located 1-6 mm from the arterial wall and protect tissues within 1 mm. RF power and cooling flow rate are controlled by the Paradise Generator which can energize transducers in the 8.5-9.5 MHz frequency range. Computer simulations and tissue-mimicking phantom models were used to develop the proper power, cooling flow rate and sonication duration settings to provide consistent tissue ablation for renal arteries ranging from 5-8 mm in diameter. The modulation of these three parameters allows for control over the near-field (border of lesion closest to arterial wall) and far-field (border of lesion farthest from arterial wall, consisting of the adventitial and peri-adventitial spaces) depths of the tissue lesion formed by the absorption of ultrasonic energy and conduction of heat. Porcine studies have confirmed the safety (protected intimal and medial layers) and effectiveness (ablation of 1-6 mm region) of the system and provided near-field and far-field depth data to correlate with bench and computer simulation models. The safety and effectiveness of the Paradise System, developed through computer model, bench and in vivo studies, has been demonstrated in human clinical studies.

  9. Presentation of the GIE INTRA Group's operational means

    International Nuclear Information System (INIS)

    Cochard, A.

    2010-01-01

    Located on the Chinon nuclear power plant site, the Intra Group is an economic interest grouping which has been created by the three French nuclear operators (EDF, CEA, and COGEMA now AREVA) after the Chernobyl accident. Its missions are to possess permanently available means of intervention in case of severe accident or radiological situation, to be able to intervene at any time on the French territory, to develop a European network of expertise, and to build up an ability centre for robotic intervention in hostile environment. This document briefly presents its different available means: remotely controlled equipment (inside and outside equipment, public works equipment), and radiological characterization equipment. Other aspects are briefly evoked: organization, information transmission, exercises and interventions, international relationships, future trends

  10. Comparison of dynamic ultrasound and stress radiology for assessment of inferior glenohumeral laxity in asymptomatic shoulders

    International Nuclear Information System (INIS)

    Cheng, S.C.; Wallace, W.A.; Hulse, D.; Fairbairn, K.J.; Clarke, M.

    2008-01-01

    To determine the level of agreement between dynamic ultrasound imaging and stress radiography used for the measurement of inferior glenohumeral laxity in asymptomatic shoulders, and to determine the repeatability of the dynamic ultrasound technique. Using a custom-made stress device to apply an inferior displacement force of 90 N, we assessed 20 asymptomatic male subjects for inferior glenohumeral laxity, using stress radiography and dynamic ultrasound. Paired differences between the two methods were evaluated by the 95% limits of agreement method. At a separate session, 19 subjects had inferior glenohumeral laxity assessed by two observers, using dynamic ultrasound. Inter- and intra-observer repeatability was determined for the ultrasound technique. The mean [± standard deviation (SD)] inferior translation was 4.7 ± 4.1 mm by stress radiography and 4.4 ± 2.3 mm by dynamic ultrasound. The 95% limits of agreement showed good agreement between the two methods. The paired difference between the two measurement methods varied with the magnitude of the measurement (P < 0.001). Intra-observer repeatability of dynamic ultrasound was determined by the use of intra-class correlation coefficients and was 0.94 and 0.89 for the two investigators. Inter-observer repeatability was 0.85. The standard error of the measurement was 0.60 mm and 0.66 mm, for repeated measurements by the two investigators, and 0.85 mm between investigators. Repeatability coefficients demonstrated excellent consistency of measurement between sessions and good consistency between observers. Dynamic ultrasound is a valid and reproducible method for the assessment and quantification of inferior glenohumeral laxity. (orig.)

  11. Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement

    Directory of Open Access Journals (Sweden)

    Tuba Cimilli Ozturk

    2015-08-01

    Full Text Available Diagnosis and measuring the level of increase in intracranial pressure (ICP is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator-dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD. There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra-interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.

  12. Effect on hemostasis of an absorbable hemostatic gelatin sponge after transrectal prostate needle biopsy

    Directory of Open Access Journals (Sweden)

    Kohei Kobatake

    2015-04-01

    Full Text Available Objectives To examine the usefulness of an absorbable hemostatic gelatin sponge for hemostasis after transrectal prostate needle biopsy. Subjects and Methods The subjects comprised 278 participants who underwent transrectal prostate needle biopsy. They were randomly allocated to the gelatin sponge insertion group (group A: 148 participants and to the non-insertion group (group B: 130 participants. In group A, the gelatin sponge was inserted into the rectum immediately after biopsy. A biopsy-induced hemorrhage was defined as a case in which a subject complained of bleeding from the rectum, and excretion of blood clots was confirmed. A blood test was performed before and after biopsy, and a questionnaire survey was given after the biopsy. Results Significantly fewer participants in group A required hemostasis after biopsy compared to group B (3 (2.0% vs. 11 (8.5%, P=0.029. The results of the blood tests and the responses from the questionnaire did not differ significantly between the two groups. In multivariate analysis, only “insertion of a gelatin sponge into the rectum” emerged as a significant predictor of hemostasis. Conclusion Insertion of a gelatin sponge into the rectum after transrectal prostate needle biopsy significantly increases hemostasis without increasing patient symptoms, such as pain and a sense of discomfort.

  13. Duplex ultrasound for identifying renal artery stenosis

    DEFF Research Database (Denmark)

    Zachrisson, Karin; Herlitz, Hans; Lönn, Lars

    2017-01-01

    Background Renal artery duplex ultrasound (RADUS) is an established method for diagnosis of renal artery stenosis (RAS), but there is no consensus regarding optimal RADUS criteria. Purpose To define optimal cutoff values for RADUS parameters when screening for RAS using intra-arterial trans...

  14. Ultrasound-Guided Regional Anesthesia for Procedures of the Upper Extremity

    Directory of Open Access Journals (Sweden)

    Farheen Mirza

    2011-01-01

    Full Text Available Anesthesia options for upper extremity surgery include general and regional anesthesia. Brachial plexus blockade has several advantages including decreased hemodynamic instability, avoidance of airway instrumentation, and intra-, as well as post-operative analgesia. Prior to the availability of ultrasound the risks of complications and failure of regional anesthesia made general anesthesia a more desirable option for anesthesiologists inexperienced in the practice of regional anesthesia. Ultrasonography has revolutionized the practice of regional anesthesia. By visualizing needle entry throughout the procedure, the relationship between the anatomical structures and the needle can reduce the incidence of complications. In addition, direct visualization of the spread of local anesthesia around the nerves provides instant feedback regarding the likely success of the block. This review article outlines how ultrasound has improved the safety and success of brachial plexus blocks. The advantages that ultrasound guidance provides are only as good as the experience of the anesthesiologist performing the block. For example, in experienced hands, with real time needle visualization, a supraclavicular brachial plexus block has changed from an approach with the highest risk of pneumothorax to a block with minimal risks making it the ideal choice for most upper extremity surgeries.

  15. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    Science.gov (United States)

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  16. Extended endoscopic endonasal surgery using three-dimensional endoscopy in the intra-operative MRI suite for supra-diaphragmatic ectopic pituitary adenoma.

    Science.gov (United States)

    Fuminari, Komatsu; Hideki, Atsumi; Manabu, Osakabe; Mitsunori, Matsumae

    2015-01-01

    We describe a supra-diaphragmatic ectopic pituitary adenoma that was safely removed using the extended endoscopic endonasal approach, and discuss the value of three-dimensional (3D) endoscopy and intra-operative magnetic resonance imaging (MRI) to this type of procedure. A 61-year-old-man with bitemporal hemianopsia was referred to our hospital, where MRI revealed an enhanced suprasellar tumor compressing the optic chiasma. The tumor extended on the planum sphenoidale and partially encased the right internal carotid artery. An endocrinological assessment indicated normal pituitary function. The extended endoscopic endonasal approach was taken using a 3D endoscope in the intraoperative MRI suite. The tumor was located above the diaphragma sellae and separated from the normal pituitary gland. The pathological findings indicated non-functioning pituitary adenoma and thus the tumor was diagnosed as a supra-diaphragmatic ectopic pituitary adenoma. Intra-operative MRI provided useful information to minimize dural opening and the supra-diaphragmatic ectopic pituitary adenoma was removed from the complex neurovascular structure via the extended endoscopic endonasal approach under 3D endoscopic guidance in the intra-operative suite. Safe and effective removal of a supra-diaphragmatic ectopic pituitary adenoma was accomplished via the extended endoscopic endonasal approach with visual information provided by 3D endoscopy and intra-operative MRI.

  17. A deep learning approach for real time prostate segmentation in freehand ultrasound guided biopsy.

    Science.gov (United States)

    Anas, Emran Mohammad Abu; Mousavi, Parvin; Abolmaesumi, Purang

    2018-06-01

    Targeted prostate biopsy, incorporating multi-parametric magnetic resonance imaging (mp-MRI) and its registration with ultrasound, is currently the state-of-the-art in prostate cancer diagnosis. The registration process in most targeted biopsy systems today relies heavily on accurate segmentation of ultrasound images. Automatic or semi-automatic segmentation is typically performed offline prior to the start of the biopsy procedure. In this paper, we present a deep neural network based real-time prostate segmentation technique during the biopsy procedure, hence paving the way for dynamic registration of mp-MRI and ultrasound data. In addition to using convolutional networks for extracting spatial features, the proposed approach employs recurrent networks to exploit the temporal information among a series of ultrasound images. One of the key contributions in the architecture is to use residual convolution in the recurrent networks to improve optimization. We also exploit recurrent connections within and across different layers of the deep networks to maximize the utilization of the temporal information. Furthermore, we perform dense and sparse sampling of the input ultrasound sequence to make the network robust to ultrasound artifacts. Our architecture is trained on 2,238 labeled transrectal ultrasound images, with an additional 637 and 1,017 unseen images used for validation and testing, respectively. We obtain a mean Dice similarity coefficient of 93%, a mean surface distance error of 1.10 mm and a mean Hausdorff distance error of 3.0 mm. A comparison of the reported results with those of a state-of-the-art technique indicates statistically significant improvement achieved by the proposed approach. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Intra-Operative Surgical Irrigation of the Surgical Incision: What Does the Future Hold-Saline, Antibiotic Agents, or Antiseptic Agents?

    Science.gov (United States)

    Edmiston, Charles E; Leaper, David J

    2016-12-01

    Intra-operative surgical site irrigation (lavage) is common practice in surgical procedures in general, with all disciplines advocating some form of irrigation before incision closure. This practice, however, has been neither standardized nor is there compelling evidence that it effectively reduces the risk of surgical site infection (SSI). This narrative review addresses the laboratory and clinical evidence that is available to support the practice of irrigation of the abdominal cavity and superficial/deep incisional tissues, using specific irrigation solutions at the end of an operative procedure to reduce the microbial burden at wound closure. Review of PubMed and OVID for pertinent, scientific, and clinical publications in the English language was performed. Incision irrigation was found to afford a three-fold benefit: First, to hydrate the bed; second, to assist in allowing better examination of the area immediately before closure; and finally, by removing superficial and deep incisional contamination and lowering the bioburden, expedite the healing process. The clinical practice of intra-operative peritoneal lavage is highly variable and is dependent solely on surgeon preference. By contrast, intra-operative irrigation after device-related procedures has become a standard of care for the prophylaxis of acute peri-prosthetic infection. The clinical evidence that supports the use of antibiotic irrigation is limited and based on retrospective analysis and few acceptable randomized controlled trials. The results of laboratory and animal studies using aqueous 0.05% chlorhexidine gluconate are favorable, suggesting that further studies are justified to determine its clinical efficacy. The adoption of appropriate and standardized intra-operative irrigation practices into peri-operative care bundles, which include other evidence-based strategies (weight-based antimicrobial prophylaxis, antimicrobial sutures, maintenance of normothermia, and glycemic control), offers

  19. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  20. Framework for a low-cost intra-operative image-guided neuronavigator including brain shift compensation

    OpenAIRE

    Bucki, Marek; Lobos, Claudio; Payan, Yohan

    2007-01-01

    In this paper we present a methodology to address the problem of brain tissue deformation referred to as 'brain-shift'. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on pre-operative patient imaging to locate the surgical target, such as a tumour or a functional area. After a general description of the framework of our intra-operative image-guided system, we desc...

  1. Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

    Science.gov (United States)

    Kolega, Marija Škara; Kovačević, Suzana; Čanović, Samir; Pavičić, Ana Didović; Bašić, Jadranka Katušić

    2015-03-01

    Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

  2. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Science.gov (United States)

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  3. Infective complications in patients after transrectal ultrasound-guided prostate biopsy and the role of ciprofloxacin resistant Escherichia coli colonization in rectal flora.

    Science.gov (United States)

    Hamarat, Mustafa Bilal; Tarhan, Fatih; Horuz, Rahim; Öcal, Gülfem Akengin; Demirkol, Mehmet Kutlu; Kafkaslı, Alper; Yazıcı, Özgür

    2017-06-01

    In the present study, we aimed to invastigate the ciprofloxacin resistance in rectal flora of the patients undergoing prostate biopsy in our department. Additionally, the possible effects of the presence of ciprofloxacin resistant bacteria in faecal flora on the risk of infective complications after the procedure as well as the effect of antibiotic prophylaxis on such infectious complications have been evaluated. A total of 142 patients undergoing transrectal ultrasound-guided prostate biopsy were included into the study program. Rectal swab samples were taken from all patients prior to biopsy. The presence of complications have been evaluated after a week following the biopsy procedure. Patients with fever were also evaluated. The possible correlation between the presence of ciprofloxacin-resistant bacteria in faecal flora and the risk of urinary tract infection development and the other complications were evaluated. E. coli bacteria were present in all cultures of rectal swab samples obtained from 142 patients prior to prostate biopsy. Of all these patients, while ciprofloxacin-resistant E. coli (CR E. coli ) grew in 76 (53.5%) patients; ciprofloxacin susceptible E. coli (CS E. coli ) was obtained in 66 (46.5%) patients. In 16 patients (11.3%), infectious complications were observed. While the infective complications were present in the 14.5% of patients with CR E. coli ; they were present in the 7.6% of patients with CS E. coli (p=0.295). High fever was observed in nine patients (6.3%). Of these nine patients, although six had CR E. coli growth as detected during culture sensitivity tests; three had CS E. coli growth in their rectal swab culture tests. Sepsis was observed in three (2.1%) of these patients with high fever. Ciprofloxacin-resistant E. coli grew in all of the rectal swab cultures obtained from these patients with sepsis. In the light of our findings we may say that, it will be appropriate to reconsider the ciprofloxacin prophylaxis and prefer to use

  4. Sonography of intrathyroid parathyroid adenomas: Are there distinctive features that allow for preoperative identification?

    International Nuclear Information System (INIS)

    Heller, Matthew T.; Yip, Linwah; Tublin, Mitchell E.

    2013-01-01

    Objective: The purpose of our study was to determine if intra-thyroid parathyroid adenomas can be accurately identified by applying proposed criteria to preoperative ultrasound examinations in patients with primary hyperparathyroidism. Materials/methods: Fifty-three patients with pathology proven intra-thyroid parathyroid adenomas and pre-operative ultrasounds were identified from a surgical database for a blinded, retrospective review. A contemporary, age-matched cohort of 54 patients with extra-thyroid parathyroid adenomas was identified as a control. A total of 64 patients within these cohorts had co-existing thyroid nodules. Proposed ultrasound criteria for identifying a parathyroid adenoma included solid composition, profound hypoechogenicity, and presence of a feeding polar vessel. Parathyroid adenomas were classified as extra-thyroid or intra-thyroid (partial or complete) based on their relationship with the thyroid gland during ultrasound evaluation and results were compared to surgical and histopathology reports as the gold standard. The results from the blinded, retrospective review during which the proposed, specific ultrasound criteria were applied were compared to the initial, pre-operative reports during which the proposed criteria were not applied. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the blinded, retrospective review and initial, pre-operative reports were calculated. Additionally, in patients with co-existing thyroid nodules, an attempt was made to differentiate parathyroid adenomas from the thyroid nodules. Results: Application of the proposed ultrasound criteria during blinded retrospective review yielded a sensitivity and specificity for detecting intra-thyroid parathyroid adenomas of 76% and 92%, respectively. The sensitivity and specificity of ultrasound for detecting intra-thyroid parathyroid adenomas on the initial reports was 29% and 95%, respectively. The sensitivity and

  5. Intra-operative monitoring of the common peroneal nerve during total knee replacement.

    Science.gov (United States)

    Unwin, A J; Thomas, M

    1994-01-01

    We present a method allowing intra-operative monitoring of the common peroneal nerve during total knee arthroplasty using a magnetic stimulator. Previous reports have shown no pre-operative method successful in selecting those patients prone to develop a post-operative palsy. The device, placed beneath the lumbar spine, stimulates the cauda equina; common peroneal nerve function is assessed via the response in extensor digitorum brevis. There is a loss of signal from the nerve with the use of a tourniquet 25 min following its application. The protocol therefore requires that a tourniquet is used at least only for fixation of the prosthetic components. The method is quick, safe, non-invasive and reproducible, and is of use both in at-risk patients and in research work. Images Figure 6. PMID:7837197

  6. Validity of Estimation of Pelvic Floor Muscle Activity from Transperineal Ultrasound Imaging in Men.

    Directory of Open Access Journals (Sweden)

    Ryan E Stafford

    Full Text Available To investigate the relationship between displacement of pelvic floor landmarks observed with transperineal ultrasound imaging and electromyography of the muscles hypothesised to cause the displacements.Three healthy men participated in this study, which included ultrasound imaging of the mid-urethra, urethra-vesical junction, ano-rectal junction and bulb of the penis. Fine-wire electromyography electrodes were inserted into the puborectalis and bulbocavernosus muscles and a transurethral catheter electrode recorded striated urethral sphincter electromyography. A nasogastric sensor recorded intra-abdominal pressure. Tasks included submaximal and maximal voluntary contractions, and Valsalva. The relationship between each of the parameters measured from ultrasound images and electromyography or intra-abdominal pressure amplitudes was described with nonlinear regression.Strong, non-linear relationships were calculated for each predicted landmark/muscle pair for submaximal contractions (R2-0.87-0.95. The relationships between mid-urethral displacement and striated urethral sphincter electromyography, and bulb of the penis displacement and bulbocavernosus electromyography were strong during maximal contractions (R2-0.74-0.88. Increased intra-abdominal pressure prevented shortening of puborectalis, which resulted in weak relationships between electromyography and anorectal and urethravesical junction displacement during all tasks.Displacement of landmarks in transperineal ultrasound imaging provides meaningful measures of activation of individual pelvic floor muscles in men during voluntary contractions. This method may aid assessment of muscle function or feedback for training.

  7. Intra-operative multi-site stimulation: Expanding methodology for cortical brain mapping of language functions.

    Science.gov (United States)

    Gonen, Tal; Gazit, Tomer; Korn, Akiva; Kirschner, Adi; Perry, Daniella; Hendler, Talma; Ram, Zvi

    2017-01-01

    Direct cortical stimulation (DCS) is considered the gold-standard for functional cortical mapping during awake surgery for brain tumor resection. DCS is performed by stimulating one local cortical area at a time. We present a feasibility study using an intra-operative technique aimed at improving our ability to map brain functions which rely on activity in distributed cortical regions. Following standard DCS, Multi-Site Stimulation (MSS) was performed in 15 patients by applying simultaneous cortical stimulations at multiple locations. Language functioning was chosen as a case-cognitive domain due to its relatively well-known cortical organization. MSS, performed at sites that did not produce disruption when applied in a single stimulation point, revealed additional language dysfunction in 73% of the patients. Functional regions identified by this technique were presumed to be significant to language circuitry and were spared during surgery. No new neurological deficits were observed in any of the patients following surgery. Though the neuro-electrical effects of MSS need further investigation, this feasibility study may provide a first step towards sophistication of intra-operative cortical mapping.

  8. Use of auditory evoked potentials for intra-operative awareness in anesthesia: a consciousness-based conceptual model.

    Science.gov (United States)

    Dong, Xuebao; Suo, Puxia; Yuan, Xin; Yao, Xuefeng

    2015-01-01

    Auditory evoked potentials (AEPs) have been used as a measure of the depth of anesthesia during the intra-operative process. AEPs are classically divided, on the basis of their latency, into first, fast, middle, slow, and late components. The use of auditory evoked potential has been advocated for the assessment of Intra-operative awareness (IOA), but has not been considered seriously enough to universalize it. It is because we have not explored enough the impact of auditory perception and auditory processing on the IOA phenomena as well as on the subsequent psychological impact of IOA on the patient. More importantly, we have seldom tried to look at the phenomena of IOP from the perspective of consciousness itself. This perspective is especially important because many of IOA phenomena exist in the subconscious domain than they do in the conscious domain of explicit recall. Two important forms of these subconscious manifestations of IOA are the implicit recall phenomena and post-operative dreams related to the operation. Here, we present an integrated auditory consciousness-based model of IOA. We start with a brief description of auditory awareness and the factors affecting it. Further, we proceed to the evaluation of conscious and subconscious information processing by auditory modality and how they interact during and after intra-operative period. Further, we show that both conscious and subconscious auditory processing affect the IOA experience and both have serious psychological implications on the patient subsequently. These effects could be prevented by using auditory evoked potential during monitoring of anesthesia, especially the mid-latency auditory evoked potentials (MLAERs). To conclude our model with present hypothesis, we propose that the use of auditory evoked potential should be universal with general anesthesia use in order to prevent the occurrences of distressing outcomes resulting from both conscious and subconscious auditory processing during

  9. Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients.

    Science.gov (United States)

    Cho, Ki Hun; Lee, Hwang Jae; Lee, Wan Hee

    2017-07-01

    Dysfunction of skeletal muscle has been commonly reported in stroke patients. The purpose of this study was to investigate the intra- and inter-rater reliabilities of measurement of ultrasound imaging (USI) for pennation angle (PA) and muscle thickness (MT) of tibialis anterior muscle in stroke patients. Thirty-four stroke patients (19 men) participated in this study. USI was used for measurement of PA and MT of the tibialis anterior muscles at rest and during maximum voluntary contraction (MVC). Two examiners acquired images from all participants during two separate testing sessions, seven days apart. Intra-class correlation coefficients (ICCs), confidence interval (CI), standard error of measurement, minimal detectable change, and Bland-Altman plots were used for estimation of reliability. In the intra-rater reliability between measures, for all variables (PA and MT of the paretic and non-paretic sides of tibialis anterior muscles at rest and during MVC), the ICCs ranged between 0.639 and 0.998 and the CI was within an acceptable range of 0.388-0.999. In inter-rater reliability between examiners for the two tests, for all variables, the ICCs ranged between 0.690 and 0.995 and the CI was within an acceptable range of 0.463-0.997. In addition, significant difference was observed between the paretic and non-paretic sides of the tibialis anterior muscle architecture (p stroke patients. In addition, objective and quantitative measurements of tibialis anterior muscle using USI may provide appropriate management for the walking recovery of stroke patients.

  10. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements; Variabilita' intra- ed interoperatore delle misure ecografiche del volume e dell'indice di resistenza del rene trapiantato

    Energy Technology Data Exchange (ETDEWEB)

    Mancini, Marcello; Liuzzi, Raffaele [CNR, Napoli (Italy). Istituto di biostrutture e bioimmagini; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco [Napoli Univ., Napoli (Italy). Dipartimento di diagnostica per immagini; Sabbatini, Massimo; Cianciaruso, Bruno [Napoli Univ., Napoli (Italy). Istituto di nefrologia medica; Ferrara, Liberato Aldo [Napoli Univ., Napoli (Italy). Dipartimento di medicina clinica e sperimentale

    2005-04-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8{+-}12,4 years (M{+-}SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels {<=}123,76 {mu}mol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 {mu}mol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was <5%. The analysis of the Student's test did not show any significant difference between the measurements (t=0.15; p=0.87 n.s.). A good reproducibility was also detected in US measurements of renal length and volume. Conclusions: These results suggest that Color Doppler Resistive Index measurements of renal allograft and Ultrasound renal volume measurements are repeatable and reproducible. [Italian] Scopo: Valutare la ripetibilit� e la riproducibilit� delle misurazioni ecografiche dell'Indice di Resistenza (I.R.) e del volume del rene trapiantato. Materiale e metodi: Ventisei pazienti (18 uomini, 8 donne) con et� media di 42,8{+-}12,4 anni (M{+-}SD)(range 22-65 anni) sono stati studiati consecutivamente due volte con eco-color-Doppler da due ecografisti esperti. Dodici pazienti avevano funzione renale normale (livello serico di creatina stabilmente {<=}123,76 {mu}mol/L, i rimanenti 14 avevano una lieve e stabile disfunzione del rene trapiantato (creatina serica 132.6-265.2 {mu

  11. An improved adaptive wavelet shrinkage for ultrasound despeckling

    Indian Academy of Sciences (India)

    Preservation Index (EPI). A comparison of the results shows that the proposed fil- ter achieves an improvement in terms of quantitative measures and in terms of visual quality of the images. Keywords. Wavelet; translation invariance; inter and intra scale dependency; speckle; adaptive thresholding; ultrasound images. ∗.

  12. Sonographic criteria for therapy follow-up in the course of ultrasound-guided intra-articular injections of hyaluronic acid in hand osteoarthritis

    International Nuclear Information System (INIS)

    Klauser, Andrea S.; Faschingbauer, Ralph; Kupferthaler, Karin; Feuchnter, Gudrun; Wick, Marius C.; Jaschke, Werner R.; Mur, Erich

    2012-01-01

    Objective: To assess the value of sonographic criteria, based on measurements of joint capsule distension and synovial hyperemia, during the course of repeated ultrasound (US)-guided intra-articular injections of hyaluronic acid (HA) in hand osteoarthritis (OA). Materials and methods: Thirty-three patients (28 females/5 males), with hand OA in 78 joints, were included in this study. Patients underwent sonographic evaluation at baseline and consecutively for 4 weeks at weekly US-guided intra-articular injections of HA (Hyalgan ® ). Measurements of joint thickening and joint inflammation were performed with Grey-scale and semi-quantitative Power-Doppler US (PDUS). Sonographic values were correlated with weekly patients self-assessment of pain for each treated joint. Results: The mean (SD) patients self-assessment of pain statistically significantly (p < 0.0001) decreased from the first [68.3(22.3)] to the last week [37.3(30.34)]. A steady pain relief could be noticed in 67 (86%) of all treated joints. Over the whole observation period, the mean (SD) joint thickening of all joints markedly decreased from 15.6 mm (5.3) to 13.1 mm (6.4) (p < 0.0001). The PDUS-score before initiation of HA treatment was statistically significantly higher than at the end of therapy (p < 0.0001). The decrease in pain statistically significantly correlated with the decrease of joint thickening and PDUS-score between baseline and the end of therapy (p < 0.001). Conclusion: In this study, we demonstrate the meaningfulness of sonographic evaluation criteria including measurements of joint capsule distension and PDUS vascularization, both significantly correlating with the decrease of pain, during the therapy follow-up of US-guided intra-articular HA-injections in patients with hand OA.

  13. Frequency of operative trauma to anal sphincters: evaluation with endoanal ultrasound.

    Science.gov (United States)

    Stamatiadis, Apostolos; Konstantinou, Evangelos; Theodosopoulou, Eleni; Mamoura, Konstantinia

    2002-01-01

    Sphincter trauma after anorectal surgery is usually asymptomatic. Frequency of trauma cannot be established with the clinical examination only. The frequency of operative sphincter defects and their correlation with disorders of continence was evaluated with the endoanal ultrasound. This study includes 123 subjects who had undergone anorectal surgery in the past and were examined with endoanal ultrasound for various indications such as continence disorders, recurrent fistula, idiopathic perineal pain, or simple postoperative follow-up. No subjects had isolated external anal sphincter defects. Nineteen of 123 patients (15%) had minor or major continence disorders, 55 patients (45%) had no sphincter defects, 42 (34%) had only internal anal sphincter (IAS) defects, and 26 (21%) had simultaneously external and internal anal sphincter (EAS) defects. The incidence of IAS and EAS trauma after Milligan-Morgan hemorrhoidectomy was 1/18 (5.5%) and 0/18 respectively; after fistula repair, 24/42 (57%) and 12/42 (29%); and after anal dilatation, 13/17 (76%) and 4/17 (24%). Sixteen of 26 patients (62%) with EAS trauma and 51/68 patients (75%) with IAS trauma did not report any disorders of continence. In patients with two or more operations, the frequency of IAS trauma was 74%, 30% for EAS trauma, and 26% for continence disorders.

  14. Incidentally detection of non-palpable testicular nodules at scrotal ultrasound: What is new?

    Directory of Open Access Journals (Sweden)

    Massimo Valentino

    2014-12-01

    Full Text Available The increased use of ultrasound in patients with urological and andrological symptoms has given an higher detection of intra-testicular nodules. Most of these lesions are hypoechoic and their interpretation is often equivocal. Recently, new ultrasound techniques have been developed alongside of B-mode and color-Doppler ultrasound. Although not completely standardized, contrast-enhanced ultrasound (CEUS and tissue elastography (TE, added to traditional ultrasonography, can provide useful information about the correct interpretation of incidentally detected non-palpable testicular nodules. The purpose of this review article is to illustrate these new techniques in the patient management.

  15. Histoscanning and shear wave ultrasound elastography for prostate cancer diagnosis

    Directory of Open Access Journals (Sweden)

    A. V. Amosov

    2016-01-01

    Full Text Available Introduction. The shear wave ultrasound elastography is a recently developed ultrasound-based method in the clinical practice, which allows the qualitative visual and quantitative measurements of tissue stiffness. In the 2010 this technology of the shear wave was called Shear Wave Elastograhpy. Due to the front of the shear waves the qualitative and quantitative assessment of the tissue stiffness is possible.Objective is to examine the efficacy of the shear wave ultrasound elastography in the evaluation of the prevalence of the oncological disease in patients with the prostate cancer and to compare the obtained results with the routine method X-ray diagnostics.Materials and methods. From the april 2015 in the I.M. Sechenov First Moscow State Medical University Urology Clinic there were conducted 314 shear wave ultrasound elastography examinations of the prostate. The ultrasound system Aixplorer® by SuperSonic Imagine was used. This system provides information provided by B-mode and shear wave ultrasound elastography mode. The transrectal echograms were made in 6 dimensions, so called Q-boxes (3 demensions in the every lobe on the segments from the base to the apex, according to the biopsy zone. The unit of measurement was the mean value in the kilopaskals (kPa. All the patients were randomized into 3 groups. There were 146 men with the possible prostate cancer in the first group (prospective study, 120 men with the certain diagnosis of the prostate cancer in the second group (retrospective study and 48 healthy men in the third group (control study. In all the patients of the first and the second groups the routine complete examination, including the prostate specific antigen (PSA level examination, digital rectal examination (DRE, doppler transrectal ultrasonography (TRUS, histoscanning and ultrasound shear wave elastography (SWE, was conducted. In the 229 patients of the first and the second groups the prostatectomy with the

  16. Managing Caesarean Scar Pregnancy in low Resource Settings: 2 ...

    African Journals Online (AJOL)

    AJRH Managing Editor

    ultrasound guided approach with dilatation of uterine cervix and subsequent evacuation of uterine ... Keywords: caesarean scar pregnancy, transrectal ultrasound guided surgical approach. ... a viable embryo with a crown rump length (CRL).

  17. From Grey Scale B-Mode to Elastosonography: Multimodal Ultrasound Imaging in Meningioma Surgery-Pictorial Essay and Literature Review.

    Science.gov (United States)

    Prada, Francesco; Del Bene, Massimiliano; Moiraghi, Alessandro; Casali, Cecilia; Legnani, Federico Giuseppe; Saladino, Andrea; Perin, Alessandro; Vetrano, Ignazio Gaspare; Mattei, Luca; Richetta, Carla; Saini, Marco; DiMeco, Francesco

    2015-01-01

    The main goal in meningioma surgery is to achieve complete tumor removal, when possible, while improving or preserving patient neurological functions. Intraoperative imaging guidance is one fundamental tool for such achievement. In this regard, intra-operative ultrasound (ioUS) is a reliable solution to obtain real-time information during surgery and it has been applied in many different aspect of neurosurgery. In the last years, different ioUS modalities have been described: B-mode, Fusion Imaging with pre-operative acquired MRI, Doppler, contrast enhanced ultrasound (CEUS), and elastosonography. In this paper, we present our US based multimodal approach in meningioma surgery. We describe all the most relevant ioUS modalities and their intraoperative application to obtain precise and specific information regarding the lesion for a tailored approach in meningioma surgery. For each modality, we perform a review of the literature accompanied by a pictorial essay based on our routinely use of ioUS for meningioma resection.

  18. Evaluation of clinical efficacy of transrectal sonography and computed tomography for prostatic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroki; Ohe, Hiroshi; Tanahashi, Toshikatsu and others

    1988-07-01

    Receiver operating characteristics (ROC) analysis was performed to evaluate the clinical efficacy of transrectal sonography (US) and computed tomography (CT) for prostatic diseases. One hundred US and CT images of prostatic diseases collected from 10 medical institutions, including 33 cases of prostatic cancer, 29 of benign prostatic hypertrophy, 7 of prostatitis, 2 of prostatic stone and 29 of normal finding, were read by 21 urologists. As the results, US was found to be more useful than CT for both the detection of prostatic diseases and the differentiation between prostatic cancer and benign prostatic hypertrophy. The sensitivity of US for the diagnosis of prostatic cancer was 64.2 % on average of all the urologists. However, the sensitivity was 80.0 % on average of 5 urologists who have read more than 3,000 US images and 59.5 % on average of 16 doctors who have read within 3,000 US images.

  19. Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs

    OpenAIRE

    Kneif, D.; Downing, M.; Ashcroft, G. P.; Gibson, P.; Knight, D.; Ledingham, W.; Hutchison, J.

    2005-01-01

    Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreem...

  20. The results of transrectal prostate biopsy in patients with low levels of prostate specific antigen

    Directory of Open Access Journals (Sweden)

    Ahmet Ali Sancaktutar

    2012-06-01

    Full Text Available Objectives: The aim of this study is to evaluate the resultsof prostate biopsy of patients who had the prostatespecificantigen (PSA levels below 4 ng/ml.Material and methods: The medical records of 63 patientswho underwent transrectal prostate biopsy, betweenJanuary 2005 and December 2011, due to suspicionof prostate cancer with the PSA levels under 4 ng/mlwere retrospectively reviewed.Results: Transrectal Prostate biopsy was performed to63 patients. Prostate cancer was detected in 12 (19%patients. The mean value of PSA was 2.5 ng/ml. TheGleason score of Prostate cancer patients was 6,8 (5-7and the number of positive cores were 3.Conclusions: The rate of prostate cancer was found as19% in patients with levels of PSA under 4 ng/ml and thisratio is compatible with the results of previous reports.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is as well as the object's size, shape and consistency (whether the object is solid or ... you lying on your back, possibly with your feet in stirrups similar to a gynecologic exam. Transrectal: ...

  2. Inter-operator Variability in Defining Uterine Position Using Three-dimensional Ultrasound Imaging

    DEFF Research Database (Denmark)

    Baker, Mariwan; Jensen, Jørgen Arendt; Behrens, Claus F.

    2013-01-01

    significantly larger inter-fractional uterine positional displacement, in some cases up to 20 mm, which outweighs the magnitude of current inter-operator variations. Thus, the current US-phantom-study suggests that the inter-operator variability in addressing uterine position is clinically irrelevant.......In radiotherapy the treatment outcome of gynecological (GYN) cancer patients is crucially related to reproducibility of the actual uterine position. The purpose of this study is to evaluate the inter-operator variability in addressing uterine position using a novel 3-D ultrasound (US) system....... The study is initiated by US-scanning of a uterine phantom (CIRS 404, Universal Medical, Norwood, USA) by seven experienced US operators. The phantom represents a female pelvic region, containing a uterus, bladder and rectal landmarks readily definable in the acquired US-scans. The organs are subjected...

  3. Association between placentome size, measured using transrectal ultrasonography, and gestational age in cattle.

    Science.gov (United States)

    Adeyinka, F D; Laven, R A; Lawrence, K E; van Den Bosch, M; Blankenvoorde, G; Parkinson, T J

    2014-03-01

    The aim of this study was to estimate whether fetal age could be accurately estimated using placentome size. Fifty-eight cows with confirmed conception dates in two herds were used for the study. The length of the long axis and cross-sectional area of placentomes close to the cervix were measured once every 10 days between approximately 60-130 days of gestation and once every 15 days between 130-160 days of gestation. Four to six placentomes were measured using transrectal ultrasonography in each uterine horn. A linear mixed model was used to establish the factors that were significantly associated with log mean placentome length and to create an equation to predict gestational age from mean placentome length. Limits of agreement analysis was then used to evaluate whether the predictions were sufficiently accurate for mean placentome length to be used, in practice, as a method of determining gestational age. Only age of gestation (puterine horn (p=0.048) were found to have a significant effect on log mean placentome length. From the three models used to predict gestational age the one that used log mean placentome length of all placentomes, adjusting for the effect of horn, had the smallest 95% limits of agreement; ±33 days. That is, predicted gestational age had a 95% chance of being between 33 days greater and 33.7 days less than actual age. This is approximately twice that reported in studies using measurement of fetal size. Measurement of placentomes near to the cervix using transrectal ultrasonography was easily achieved. There was a significant association between placentome size and gestational age, but between-cow variation in placentome size and growth resulted in poor agreement between placentome size and gestational age. Although placentomes can be easily visualised during diagnosis of pregnancy using transrectal ultrasonography, mean placentome size should not be used to estimate gestational age.

  4. Intra-Operative Amylase Concentration in Peri-Pancreatic Fluid Predicts Pancreatic Fistula After Distal Pancreatectomy.

    Science.gov (United States)

    Nahm, Christopher B; de Reuver, Philip R; Hugh, Thomas J; Pearson, Andrew; Gill, Anthony J; Samra, Jaswinder S; Mittal, Anubhav

    2017-06-01

    Post-operative pancreatic fistula (POPF) is a potentially severe complication following distal pancreatectomy. The aim of this study was to assess the predictive value of intra-operative amylase concentration (IOAC) in peri-pancreatic fluid after distal pancreatectomy for the diagnosis of POPF. Consecutive patients who underwent a distal pancreatectomy between November 2014 and September 2016 were included in the analysis. IOAC was measured, followed by drain fluid analysis for amylase on post-operative days (PODs) 1, 3, and 5. Receiver operator characteristic (ROC) analysis was performed to evaluate the discriminative capacity of IOAC as a predictor of POPF. IOAC was measured after distal pancreatectomy in 26 patients. The IOAC correlated significantly with (i) PODs 1, 3, and 5 drain amylase (p  1000 experienced a post-operative complication (OR 18.3, 95% CI 2.51-103, p pancreatectomy.

  5. Developing an emergency ultrasound app

    DEFF Research Database (Denmark)

    Foss, Kim Thestrup; Subhi, Yousif; Aagaard, Rasmus

    2015-01-01

    Focused emergency ultrasound is rapidly evolving as a clinical skill for bedside examination by physicians at all levels of education. Ultrasound is highly operator-dependent and relevant training is essential to ensure appropriate use. When supplementing hands-on focused ultrasound courses, e-le...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... vaginal sonogram is usually more comfortable than a manual gynecologic examination. For a transrectal exam: If no ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  7. Evaluation of the use of intra-operative radiology for open placement of lag screws for the stabilization of sacroiliac luxation in cats.

    Science.gov (United States)

    Silveira, Francisco; Quinn, Robert J; Adrian, Anna M; Owen, Martin R; Bush, Mark A

    2017-01-16

    To assess the effect of intra-operative radiology on the quality of lag screw insertion for the management of sacroiliac joint luxations in cats. In this retrospective single-centre study, the surgical, anaesthetic and imaging records of 40 screws (32 cats) placed with lag effect for management of sacroiliac luxation were reviewed. Postoperative radiographs were assessed for sacroiliac joint reduction, screw position, and sacral width purchased by each screw. Cases were divided into two groups according to the use of (IOR) or the absence of intra-operative radiology (NIOR). A total of 23 lag screws were placed with the aid of intra-operative radiology and 17 without. Three of the 23 screws placed in the IOR group exited the sacrum as opposed to eight of 17 screws in the NIOR group (p = 0.03). Mean sacral width purchased by the screws in the IOR group (70.8%) was also significantly higher (p = 0.002) than in the NIOR group (54.6%). Mean general anaesthetic times for unilateral and bilateral screw placement for the IOR group and NIOR group were not significantly different. The use of intra-operative radiology can significantly improve the quality of lag screw insertion for the stabilization of sacroiliac luxations in cats, which should lead to a reduced incidence of postoperative screw loosening.

  8. An investigation into the causes of unexpected intra-operative transoesophageal echocardiography findings.

    Science.gov (United States)

    Skinner, H J; Mahmoud, A; Uddin, A; Mathew, T

    2012-04-01

    There is uncertainty regarding echocardiography before cardiac surgery, especially with regard to timing and disease progression as well as potential errors. We investigated the causes of unexpected intra-operative transoesophageal echocardiography findings by performing a 33-month audit. We found that there were 50/797 (6%) unexpected findings that led to an alteration in surgical strategy in 34 (4%) patients. Of the unexpected findings, 25 (50%) were unrelated to pre-operative pathology. After reviewing pre-operative studies and reports, unexpected findings were found to be due to: reporting errors in 20 patients (44%); limitations in transthoracic compared to transoesophageal echocardiography in 14 patients (30%); disease progression in 10 patients (22%); and inter-observer variability in two patients (4%). We identified six reports out of 797 (0.8%) that contained potentially serious errors. Surgical management changed in 18/20 (90%) patients in whom the unexpected change was due to reporting error, compared to 16/30 (53%) patients whose pre-operative echocardiogram was correctly reported (p = 0.006). Our study suggests that pre-operative echocardiography reporting errors are common and important. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  9. Malakoplakia of the prostate diagnosed by elevated PSA level and transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Sacit Nuri Görgel

    2011-04-01

    Full Text Available Malakoplakia is an inflammation which is thought to develop secondary to chronic Escherichia coli infections. Although often seen in the genitourinary tract, it can also be seen in colon, stomach, lung, liver, bone, uterus, and skin. In this case report, we present prostatic malakoplakia diagnosed by elevated prostate-specific antigen level and transrectal prostate biopsy.

  10. Sedation as an alternative method to lessen patient discomfort due to transrectal ultrasonography-guided prostate biopsy

    International Nuclear Information System (INIS)

    Turgut, A.T.; Ergun, E.; Kosar, U.; Kosar, P.; Ozcan, A.

    2006-01-01

    Background: Despite being highly efficient for the relief of patient discomfort due to transrectal ultrasound (TRUS) guided prostate biopsy, periprostatic anesthesia is occasionally reported to be of limited use. We aimed to evaluate the efficacy of conscious sedation, an accepted method for lessening patient discomfort due to interventional radiological procedures and compare it with periprostatic anesthesia. Methods: 93 candidates for biopsy were randomised to three groups: group 1 (n = 31) received intravenous midazolam, group 2 (n = 31) received periprostatic lidocaine injection, whereas group 3 (n = 31) received no anesthetic before the procedure. After the biopsy patients were asked to express discomfort by visual anologue scale (VAS). Results: The mean scores for groups 1 and 2 were significantly lower than that of group 3 (1.4 ± 1.1 and 2.0 ± 1.5 versus 4.7 ± 1.6, respectively; p < 0.05 for both). For patients with VAS scores exceeding 4 (moderate to severe discomfort), a significant difference was calculated between groups 1 and 2 (3% versus 29%, p < 0.05) and between each and group 3 (3% and 29% versus 80%, respectively; p < 0.05 for each). Conclusions: Sedation is an alternative for increasing patient comfort during TRUS-guided prostate biopsy, especially in clinical situations like patient anxiety, young age, repeat biopsies or inflammatory anal diseases

  11. Research interface for experimental ultrasound imaging - the CFU grabber project

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Hemmsen, Martin Christian; Jensen, Jørgen Arendt

    system RASMUS. Furthermore precise scanner settings are stored for inter- and intra-observer studies. The resulting images are used for clinical evaluation. Method and materials The ultrasound scanners research interface is connected to a graphical grabber card in a Windows PC (Grabber PC). The grabber...

  12. Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

    Science.gov (United States)

    Inguglia, Elena S; Zhang, Zhihang; Burgess, Catherine; Kerry, Joseph P; Tiwari, Brijesh K

    2018-02-01

    The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3, 0.5, and 0.8cm) on NaCl diffusion were investigated. Changes in the moisture content and NaCl gain were used to evaluate salt distribution and diffusion in the samples, parallel and perpendicular to ultrasound propagation direction. Results showed that 0.3cm was the most efficient distance between the probe and the sample to ensure a higher salt diffusion rate. A distance of 0.5cm was however considered as a trade-off distance to ensure salt diffusion and maintenance of meat quality parameters. The enhancement of salt diffusion by ultrasound was observed to decrease with increased horizontal distance from the probe. This study is of valuable importance for meat processing industries willing to apply new technologies on a larger scale and with defined operational standards. The data suggest that the geometric parameters of ultrasound systems can have strong influence on the efficiency of ultrasonic enhancement of NaCl uptake in meat and can be a crucial element in determining salt uptake during meat processing. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Preoperative Thyroid Ultrasound Is Indicated in Patients Undergoing Parathyroidectomy for Primary Hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Cletus A. Arciero, Zita S. Shiue, Jeremy D. Gates, George E. Peoples, Alan P. B. Dackiw, Ralph P. Tufano, Steven K. Libutti, Martha A. Zeiger, Alexander Stojadinovic

    2012-01-01

    Full Text Available Background: Primary hyperaparathyroidism (pHPT is often accompanied by underlying thyroid pathology that can confound preoperative parathyroid localization studies and complicate intra-operative decision making. The aim of this study was to examine the utility of preoperative thyroid ultrasonography (US in patients prior to undergoing parathyroidectomy for pHPT.Methods: An Institutional Review Board approved prospective study was undertaken from January 2005 through July 2008. All patients with pHPT meeting inclusion criteria (n=94 underwent preoperative thyroid ultrasound in addition to standard 99mTc-sestamibi scintigraphy for parathyroid localization. Demographics, operative management and final pathology were examined in all cases.Results: Fifty-four of the 94 patients (57% were noted to have a thyroid nodule on preoperative US, of which 30 (56% underwent further examination with fine needle aspiration biopsy. Alteration of the operative plan attributable to underlying thyroid pathology occurred in 16 patients (17%, with patients undergoing either total thyroidectomy (n=9 or thyroid lobectomy (n=7. Thyroid cancer was noted in 33% of patients undergoing thyroid resection, and 6% of all patients with HPT.Conclusions: The routine utilization of preoperative thyroid ultrasound in patients prior to undergoing parathyroid surgery for pHPT is indicated. The added information from this non-invasive modality facilitates timely management of co-incidental, and sometimes malignant, thyroid pathology.

  14. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  15. The standards of an ultrasound examination of the prostate gland. Part 2

    Directory of Open Access Journals (Sweden)

    Janusz F. Tyloch

    2017-03-01

    Full Text Available The paper discusses the rules of the proper performing of the ultrasound examination of the prostate gland. It has been divided into two parts: the general part and the detailed part. The first part presents the necessary requirements related to the ultrasound equipment needed for performing transabdominal and transrectal examinations of the prostate gland. The second part presents the application of the ultrasound examination in benign prostatic hyperplasia, in cases of prostate inflammation and in prostate cancer. Ultrasound examinations applied in the diagnostics of benign prostatic hyperplasia accelerated the diagnosis, facilitated the qualification to surgery and the selection of the treatment method. The assessment of the size of the prostate gland performed using the endorectal ultrasound examination is helpful in making the choice between transurethral electroresection and adenomectomy. In prostate inflammation this examination should be performed with particular gentleness due to pain ailments. The indication for performing the examination in acute inflammation is the suspicion of prostate abscess. In chronic, exacerbating prostatitis it is possible to perform an intraprostatic antibiotic injection. In the recent years increased morbidity and detectability of prostate gland cancer is observed among men. In Poland it ranks second (13% among diseases occurring in men. The indication for an endorectal examination is the necessity to assess the size of the prostate gland, its configuration, the echostructure in classical ultrasonography, the vascularization in an ultrasound examination performed with power doppler and, if possible, the differences in the gland tissue firmness (consistency in elastography. The ultrasound examination is used for performing the mapping biopsy of the prostate gland – from routine, strictly defined locations, the targeted biopsy – from locations suspected of neoplastic proliferation and the staging biopsy

  16. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  17. Ultrasound imaging for the rheumatologist XXX. Sonographic assessment of the painful knee.

    Science.gov (United States)

    Meenagh, G; Filippucci, E; Delle Sedie, A; Iagnocco, A; Scirè, C A; Riente, L; Montecucco, C; Valesini, G; Bombardieri, S; Grassi, W

    2010-01-01

    The knee joint is a frequent focus of attention for rheumatologists when assessing patients presenting to a clinic and may represent underlying intra-articular inflammatory pathology or involvement of the surrounding soft tissues. This study describes the correlation between clinical and ultrasound findings in patients presenting with a variety of rheumatic disorders and knee pain. US imaging provides for a sensitive and detailed identification of different intra- and peri-articular pathology responsible for knee pain.

  18. Intra-operative radiation therapy in cancer of the pancreas

    International Nuclear Information System (INIS)

    Dubois, J.B.; Gu, S.D.; Saint-Aubert, B.; Joyeux, H.; Solassol, C.; Pujol, H.

    1991-01-01

    We report our experience concerning 22 pancreatic carcinoma bearing patients treated with intra-operative radiation therapy (IORT) after complete surgical excision: duodenopancreatectomy: 15 patients; isthmic and caudal pancreatectomy: 2 patients; total pancreatectomy: 5 patients. The dose delivered to the tumor bed was 20 Gy in 12 patients, 18 Gy in 3 patients and 15 Gy in 7 patients. Three patients died within the 1st month post-surgery from intercurrent diseases. Post-operative morbidity was not significantly modified by IORT as compared to purely surgical treated patients. Out of 19 evaluable patients, we observed local control in 16 patients (79.4%). Causes of death (15/19 patients) were: distant metastases with local control: 7 patients; in situ local failure: 3 patients; regional recurrence outside of the IORT fields: 2 patients; intercurrent diseases: 3 patients. Four patients are still alive without evolutive disease. The median overall survival is 6 months. The mean overall survival is 10.56 months. Excluding patients who died from complications and intercurrent diseases, the median survival is 10 mths and the mean survival 14.5 mths. These results emphasize the improvement in local control with IORT, but without significant improvement in survival which is dependent on local evolution and also systemic disease [fr

  19. Objective and structured assessment of lung ultrasound competence

    DEFF Research Database (Denmark)

    Skaarup, Søren Helbo; Laursen, Christian B.; Bjerrum, Anne Sofie

    2017-01-01

    RATIONALE: Point-of-care lung ultrasound imaging has substantial diagnostic value and is widely used in respiratory, emergency and critical care medicine. Like other ultrasound examinations, lung ultrasound is operator-dependent. The current recommendations for competence in lung ultrasound sets...... a fixed number of ultrasound procedures to be performed without considering different learning rates. Recommendations do not consider different uses of lung ultrasound across specialties. OBJECTIVE: To create a reliable, valid and feasible instrument to assess lung ultrasound competence that includes...... 23 ultrasound operators of different competence levels. Examination time was measured and skill was rated by experienced observers using the assessment tool. Inter-rater agreement was examined by two observers in 9 lung ultrasound examinations. RESULTS: Consensus was obtained within 3 Delphi rounds...

  20. Why and Where do We Miss Significant Prostate Cancer with Multi-parametric Magnetic Resonance Imaging followed by Magnetic Resonance-guided and Transrectal Ultrasound-guided Biopsy in Biopsy-naïve Men?

    Science.gov (United States)

    Schouten, Martijn G; van der Leest, Marloes; Pokorny, Morgan; Hoogenboom, Martijn; Barentsz, Jelle O; Thompson, Les C; Fütterer, Jurgen J

    2017-06-01

    Knowledge of significant prostate (sPCa) locations being missed with magnetic resonance (MR)- and transrectal ultrasound (TRUS)-guided biopsy (Bx) may help to improve these techniques. To identify the location of sPCa lesions being missed with MR- and TRUS-Bx. In a referral center, 223 consecutive Bx-naive men with elevated prostate specific antigen level and/or abnormal digital rectal examination were included. Histopathologically-proven cancer locations, Gleason score, and tumor length were determined. All patients underwent multi-parametric MRI and 12-core systematic TRUS-Bx. MR-Bx was performed in all patients with suspicion of PCa on multi-parametric MRI (n=142). Cancer locations were compared between MR- and TRUS-Bx. Proportions were expressed as percentages, and the corresponding 95% confidence intervals were calculated. In total, 191 lesions were found in 108 patients with sPCa. From these lesion 74% (141/191) were defined as sPCa on either MR- or TRUS-Bx. MR-Bx detected 74% (105/141) of these lesions and 61% (86/141) with TRUS-Bx. TRUS-Bx detected more lesions compared with MR-Bx (140 vs 109). However, these lesions were often low risk (39%). Significant lesions missed with MR-Bx most often had involvement of dorsolateral (58%) and apical (37%) segments and missed segments with TRUS-Bx were located anteriorly (79%), anterior midprostate (50%), and anterior apex (23%). Both techniques have difficulties in detecting apical lesions. MR-Bx most often missed cancer with involvement of the dorsolateral part (58%) and TRUS-Bx with involvement of the anterior part (79%). Both biopsy techniques miss cancer in specific locations within the prostate. Identification of these lesions may help to improve these techniques. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  1. Estudo comparativo entre três técnicas de anestesia geral para biópsia de próstata dirigida por ultrassonografia transretal Estudio comparativo entre tres técnicas de anestesia general para biopsia de próstata dirigida por ultrasonido transrectal A comparative study among three techniques of general anesthesia for ultrasound-guided transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Ricardo Antônio Guimarães Barbosa

    2010-10-01

    ésicas en ese grupo de pacientes. MÉTODO: Fueron estudiados 45 pacientes divididos en tres grupos: 1- Propofol; 2- Propofol + Bloqueo de Plexo Prostático; 3- Propofol + Fentanil. Los pacientes fueron monitorizados con presión arterial no invasiva, electrocardioscopia continua, oximetría de pulso (SpO2 e Índice Bispectral. No recibieron medicación preanestésica. Se evaluaron los parámetros hemodinámicos en el intra y postoperatorio, índice bispectral en el intraoperatorio, el dolor por la escala numérica verbal (ENV en el postoperatorio inmediato y el uso de dipirona como tratamiento del dolor postoperatorio. RESULTADOS: No hubo diferencia significativa entre los tres grupos: en las variables antropométricas, cantidad de propofol, número de fragmentos y tiempo del examen. Los parámetros hemodinámicos y la SpO2 presentaron un comportamiento semejante en los tres grupos durante el estudio. En el grupo 1, el dolor evaluado por la ENV fue más elevado y hubo una mayor necesidad de aplicar la dipirona que en los otros grupos. CONCLUSIONES: La sedación con propofol aislado para la biopsia causa un mayor dolor e incomodidad en el postoperatorio que cuando se asocia al bloqueo del plexo prostático o al fentanil sistémico. Además de la hipnosis, se hace necesario realizar la analgesia intraoperatoria para garantizar la comodidad en el postoperatorioBACKGROUND AND OBJECTIVES: Ultrasound-guided transrectal prostate biopsy is a reference in the diagnosis of prostate neoplasias. The higher the number of samples, the greater is the pain and discomfort. The objective of this study was to compare three anesthetic techniques in this group of patients. METHODS: Forty-five patients were included in this study. Patients were divided into three groups: 1 - Propofol; 2 - Propofol + Prostatic Plexus Block; 3 - Propofol + Fentanyl. Patients were monitored with non-invasive blood pressure, continuous electrocardioscopy, pulse oximetry (SpO2, and Bispectral Index. Patients did not

  2. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    Science.gov (United States)

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  3. [Changes in prostatic circulation in response to laser therapy and magnetic therapy in patients with benign prostatic hyperplasia].

    Science.gov (United States)

    2005-01-01

    The results of preoperative preparation were analysed in 59 patients with prostatic benign hyperplasia (PBH) subjected to TUR. Treatment outcomes were assessed by transrectal ultrasound (color Doppler mapping) in two groups of patients. Group 1 received combined therapy including transrectal laser radiation of the prostate, group 2--transrectal magnetotherapy. The analysis showed that laser radiation reduced insignificantly the size of the prostate and adenomatous node, improved microcirculation and circulation in the prostate. This resulted in relief of inflammation and reduction of the number of postoperative inflammatory complications. Transrectal magnetotherapy has a positive effect on vascularization and hemodynamics of the prostate, local immunity, contamination of the tissues with pathogenic flora.

  4. Intra-observer reproducibility and diagnostic performance of breast shear-wave elastography in Asian women.

    Science.gov (United States)

    Park, Hye Young; Han, Kyung Hwa; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-06-01

    Our aim was to evaluate intra-observer reproducibility of shear-wave elastography (SWE) in Asian women. Sixty-four breast masses (24 malignant, 40 benign) were examined with SWE in 53 consecutive Asian women (mean age, 44.9 y old). Two SWE images were obtained for each of the lesions. The intra-observer reproducibility was assessed by intra-class correlation coefficients (ICC). We also evaluated various clinicoradiologic factors that can influence reproducibility in SWE. The ICC of intra-observer reproducibility was 0.789. In clinicoradiologic factor evaluation, masses surrounded by mixed fatty and glandular tissue (ICC: 0.619) showed lower intra-observer reproducibility compared with lesions that were surrounded by glandular tissue alone (ICC: 0.937; p breast SWE was excellent in Asian women. However, it may decrease when breast tissue is in a heterogeneous background. Therefore, SWE should be performed carefully in these cases. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Intra-operative cerebrospinal fluid sampling versus post-operative lumbar puncture for detection of leptomeningeal disease in malignant paediatric brain tumours.

    Directory of Open Access Journals (Sweden)

    Sharon Y Y Low

    Full Text Available Leptomeningeal disease is a feared sequelae of malignant paediatric brain tumours. Current methods for its detection is the combined use of cranio-spinal MRI, and CSF cytology from a post-operative lumbar puncture. In this study, the authors hypothesize that CSF taken at the start of surgery, either from an external ventricular drain or neuroendoscope will have equal sensitivity for positive tumour cells, in comparison to lumbar puncture. Secondary hypotheses include positive correlation between CSF cytology and MRI findings of LMD. From a clinical perspective, the key aim of the study was for affected paediatric patients to avoid an additional procedure of a lumbar puncture, often performed under anaesthesia after neurosurgical intervention.This is single-institution, retrospective study of paediatric patients diagnosed with malignant brain tumours. Its main aim was to compare cytological data from CSF collected at the time of surgery versus data from an interval lumbar puncture. In addition, MRI imaging of the same cohort of patients was examined for leptomeningeal disease and corroborated against CSF tumour cytology findings.Thirty patients are recruited for this study. Data analysis demonstrates a statistically significant association between our intra-operative CSF and LP sampling. Furthermore, our results also show for significant correlation between evidence of leptomeningeal disease on MRI findings versus intra-operative CSF positivity for tumour cells.Although this is a retrospective study with a limited population, our data concurs with potential to avoid an additional procedure for the paediatric patient diagnosed with a malignant brain tumour.

  6. Analgesic efficacy of ultrasound guided versus landmark-based bilateral superficial cervical plexus block for thyroid surgery

    Directory of Open Access Journals (Sweden)

    Rasha M. Hassan

    2017-10-01

    Full Text Available Background: The use of bilateral superficial cervical plexus block (BSCPB to provide analgesia for thyroid operations remains debatable. This study was done to assess the analgesic efficacy and safety of ultrasound (US guided or landmark-based BSCPB, performed under general anesthesia, compared to systemic narcotics in thyroid surgery. Patients and methods: A total of 69 patients ASA I and II scheduled for thyroid surgery were randomly assigned into three groups (23 patients each: Group (US received US guided BSCPB. Group (LM received landmark-based BSCPB. In both groups, the block was performed under general anesthesia and before surgery using 0.5% bupivacaine 12 ml on each side. Group (C who didn’t receive any block. We measured intra-operative hemodynamics and fentanyl requirements. We also measured postoperative analgesia within 24 h of surgery as regard: pethidine consumption, visual analogue scale (VAS pain scores and time to first rescue analgesic demand. Postoperative nausea and vomiting (PONV and other adverse events were noted as well. Results: There was a significant reduction in systolic blood pressure (SBP and heart rate (HR in groups US and LM compared with group C. Intra-operative fentanyl requirements were significantly increased in group C compared to groups US and LM. Time to first analgesic request was significantly longer in groups US and LM than in group C. Postoperative pethidine consumption and VAS scores, measured during the first postoperative day, were significantly higher in group C than groups US and LM. No significant difference was noted between the three groups regarding PONV. No other adverse events were recorded. No significant differences were noted between groups US and LM. Conclusion: BSCPB (US guided or landmark-based, performed under general anesthesia, effectively decreased peri-operative analgesic requirements in thyroid operations. However, there was no significant difference in analgesic efficacy or

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... with you lying on your back, possibly with your feet in stirrups similar to a gynecologic exam. Transrectal: ... RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate ... April 01, 2017 Send us your feedback Did you find the information you were ...

  8. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  9. Intra and post-operative complications of esophageal achalasia.

    Science.gov (United States)

    Pugliese, Luigi; Peri, Andrea; Tinozzi, Francesco Paolo; Zonta, Sandro; di Stefano, Michele; Meloni, Federica; Pietrabissa, Andrea

    2013-01-01

    To evaluate and discuss all the potential complications affecting morbidity of patients treated with surgery for primary achalasia. A review of the available English literature published to date has been conducted. All articles reporting surgical experience in achalasia were examined and then were selected only those specifically inherent to the topic at issue. Mucosal perforation is the main intra-operative complication while persistence or recurrence of the disease and gastro-esophageal reflux are those mostly affecting patients afterwards, even at long-term follow-up. A few other less common morbidities, as well as the technical considerations useful to minimize and manage each complication mentioned, are reported. Minimally invasive surgery for achalasia consent to treat patients with a low rate of perioperative complications that can be managed with conservative approach in the majority of cases. Risk of esophageal cancer exists in these patients and remains although surgical therapy. Laparoscopic Heller myotomy along with partial fundoplication is a safe and effective procedure that should be considered as the treatment of choice at first evaluation of achalasic patients rather than endoscopic techniques. Robotic technology may add further contribution in diminishing perioperative complications.

  10. Intra-operative probe for brain cancer: feasibility study

    Science.gov (United States)

    Vu Thi, M. H.; Charon, Y.; Duval, M. A.; Lefebvre, F.; Menard, L.; Pitre, S.; Pinot, L.; Siebert, R.

    2007-07-01

    The present work aims a new medical probe for surgeons devoted to brain cancers, in particular glioblastoma multiforme. Within the last years, our group has started the development of a new intra-operative beta imaging probe. More recently, we took an alternative approach for the same application: a fluorescence probe. In both cases the purpose is to differentiate normal from tumor brain tissue. In a first step, we developed set-ups capable to measure autofluorescence. They are based on a dedicated epi-fluorescence design and on specific fiber optic probes. Relative signal amplitude, spectral shape and fluorescence lifetime measurements are foreseen to distinguish normal and cancer tissue by analyzing fluorophores like NADH, lipopigments and porphyrines. The autofluorescence spectra are recorded in the 460-640 nm range with a low resolution spectrometer. For lifetime measurements a fast detector (APD) is used together with a TCSPC-carte. Intrinsic wavelength- and time-resolutions are a few nm and 200 ps, respectively. Different samples have been analyzed to validate our new detection system and to allow a first configuration of our medical fluorescence probe. First results from the tissue measurements are shown.

  11. An Intra-Abdominal Desmoid Tumor, Embedded in the Pancreas, Preoperatively Diagnosed as an Extragastric Growing Gastrointestinal Stromal Tumor

    Directory of Open Access Journals (Sweden)

    Mari Mizuno

    2017-04-01

    Full Text Available A 45-year-old woman was found to have a pancreatic tumor by abdominal ultrasound performed for a medical check-up. Abdominal contrast-enhanced computed tomography showed a hypovascular tumor measuring 30 mm in diameter in the pancreatic tail. Endoscopic ultrasound-guided fine needle aspiration was performed. An extragastric growing gastrointestinal stromal tumor was thereby diagnosed preoperatively, and surgical resection was planned. Laparoscopic surgery was attempted but conversion to open surgery was necessitated by extensive adhesions, and distal pancreatectomy, splenectomy, and partial gastrectomy were performed. The histological diagnosis was an intra-abdominal desmoid tumor. A desmoid tumor is a fibrous soft tissue tumor arising in the fascia and musculoaponeurotic tissues. It usually occurs in the extremities and abdominal wall, and only rarely in the abdominal cavity. We experienced a case with an intra-abdominal desmoid tumor that was histologically diagnosed after laparotomy, which had been preoperatively diagnosed as an extragastric growing gastrointestinal stromal tumor. Although rare, desmoid tumors should be considered in the differential diagnosis of intra-abdominal tumors. Herein, we report this case with a literature review.

  12. Using low frequency and intensity ultrasound to enhance start-up and operation performance of Anammox process inoculated with the conventional sludge.

    Science.gov (United States)

    Wang, Tao; Zhang, Diandian; Sun, Yating; Zhou, Shanshan; Li, Lin; Shao, Jingjing

    2018-04-01

    A lab-scale ultrasound enhancing Anammox reactor (R1) was established and irradiated once a week by ultrasound with the optimal parameter (frequency of 25 kHz, intensity of 0.2 W cm -2 and exposure time of 3 min) obtained by batch experiments. R1 and the controlled Anammox reactor (R2) without exposure to the ultrasound were operated in parallel. The start-up period of Anammox process (53 days) in R1 was shorter than that (61 days) in R2. The nitrogen loading-enhancing period (day 53-day 135) in R1 was also shorter than that (day 61-day 151) in R2. At the end of the nitrogen loading-enhancing period, NLR (0.76 kg N m -3  d -1 ) and NRR (0.68 kg N m -3  d -1 ) of R1 were both higher than NLR (0.66 kg N m -3  d -1 ) and NRR (0.56 kg N m -3  d -1 ) of R2. Moreover, The stability of Anammox process in R1 was better than that in R2. The results demonstrated that the periodical irradiation of ultrasound enhanced the start-up and operational performance of Anammox reactor. Microbial community analysis indicated that the ultrasound accelerated the microbial succession from some other bacteria to Anammox bacteria so that shorten the start-up period of Anammox process from the conventional activated sludge. It also indicated that the ultrasound strengthened the competitive advantage of Candidatus Kuenenia stuttgartiensis in Anammox bacteria of the mature sludge so as to enhance the nitrogen removal performance of the Anammox reactor under the operation condition of high nitrogen loading. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Fracture Surgery of the extremities with the intra-operative use of 3D-RX: A randomized multicenter trial (EF3X-trial

    Directory of Open Access Journals (Sweden)

    Marmor Meir

    2011-07-01

    Full Text Available Abstract Background Posttraumatic osteoarthritis can develop after an intra-articular extremity fracture, leading to pain and loss of function. According to international guidelines, anatomical reduction and fixation are the basis for an optimal functional result. In order to achieve this during fracture surgery, an optimal view on the position of the bone fragments and fixation material is a necessity. The currently used 2D-fluoroscopy does not provide sufficient insight, in particular in cases with complex anatomy or subtle injury, and even an 18-26% suboptimal fracture reduction is reported for the ankle and foot. More intra-operative information is therefore needed. Recently the 3D-RX-system was developed, which provides conventional 2D-fluoroscopic images as well as a 3D-reconstruction of bony structures. This modality provides more information, which consequently leads to extra corrections in 18-30% of the fracture operations. However, the effect of the extra corrections on the quality of the anatomical fracture reduction and fixation as well as on patient relevant outcomes has never been investigated. The objective of this study protocol is to investigate the effectiveness of the intra-operative use of the 3D-RX-system as compared to the conventional 2D-fluoroscopy in patients with traumatic intra-articular fractures of the wrist, ankle and calcaneus. The effectiveness will be assessed in two different areas: 1 the quality of fracture reduction and fixation, based on the current golden standard, Computed Tomography. 2 The patient-relevant outcomes like functional outcome range of motion and pain. In addition, the diagnostic accuracy of the 3D-RX-scan will be determined in a clinical setting and a cost-effectiveness as well as a cost-utility analysis will be performed. Methods/design In this protocol for an international multicenter randomized clinical trial, adult patients (age > 17 years with a traumatic intra-articular fracture of the

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... an example of a transrectal transducer (probe). A prostate-specific antigen (PSA) test, which measures the amount of PSA in the blood, may be administered to determine if a patient is at high risk for ... of the prostate gland. When the examination is complete, you may ...

  15. Framework for a low-cost intra-operative image-guided neuronavigator including brain shift compensation.

    Science.gov (United States)

    Bucki, M; Lobos, C; Payan, Y

    2007-01-01

    In this paper we present a methodology to address the problem of brain tissue deformation referred to as 'brain-shift'. This deformation occurs throughout a neurosurgery intervention and strongly alters the accuracy of the neuronavigation systems used to date in clinical routine which rely solely on pre-operative patient imaging to locate the surgical target, such as a tumour or a functional area. After a general description of the framework of our intra-operative image-guided system, we describe a procedure to generate patient specific finite element meshes of the brain and propose a biomechanical model which can take into account tissue deformations and surgical procedures that modify the brain structure, like tumour or tissue resection.

  16. The OMERACT Ultrasound Group: status of current activities and research directions

    DEFF Research Database (Denmark)

    Wakefield, Richard J; D'Agostino, Maria-Antonietta; Iagnocco, Annamaria

    2007-01-01

    Ultrasound (US) is a relatively new imaging modality in rheumatology that offers great potential as a diagnostic and management tool. In 2004, an OMERACT Ultrasound Special Interest Group was formed to address the metric qualities of US as a potential outcome measure. A preliminary systematic...... review highlighted the deficiencies in the literature, particularly with regard to the reliability of interpreting and acquiring images; as a consequence, a number of exercises were proposed to address these issues. This report describes a series of iterative studies that have resulted in improved intra...

  17. Statistical shape modeling based renal volume measurement using tracked ultrasound

    Science.gov (United States)

    Pai Raikar, Vipul; Kwartowitz, David M.

    2017-03-01

    Autosomal dominant polycystic kidney disease (ADPKD) is the fourth most common cause of kidney transplant worldwide accounting for 7-10% of all cases. Although ADPKD usually progresses over many decades, accurate risk prediction is an important task.1 Identifying patients with progressive disease is vital to providing new treatments being developed and enable them to enter clinical trials for new therapy. Among other factors, total kidney volume (TKV) is a major biomarker predicting the progression of ADPKD. Consortium for Radiologic Imaging Studies in Polycystic Kidney Disease (CRISP)2 have shown that TKV is an early, and accurate measure of cystic burden and likely growth rate. It is strongly associated with loss of renal function.3 While ultrasound (US) has proven as an excellent tool for diagnosing the disease; monitoring short-term changes using ultrasound has been shown to not be accurate. This is attributed to high operator variability and reproducibility as compared to tomographic modalities such as CT and MR (Gold standard). Ultrasound has emerged as one of the standout modality for intra-procedural imaging and with methods for spatial localization has afforded us the ability to track 2D ultrasound in physical space which it is being used. In addition to this, the vast amount of recorded tomographic data can be used to generate statistical shape models that allow us to extract clinical value from archived image sets. In this work, we aim at improving the prognostic value of US in managing ADPKD by assessing the accuracy of using statistical shape model augmented US data, to predict TKV, with the end goal of monitoring short-term changes.

  18. A standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy

    Directory of Open Access Journals (Sweden)

    Kaska Serge C

    2010-12-01

    Full Text Available Abstract Background Intra-operative fluoroscopy for orthopaedic procedures frequently involves imaging in the horizontal plane, which requires the lower portion of the C-arm (x-ray tube to be rotated from an unsterile zone (beneath the table into the sterile field. To protect the integrity of the sterile field the C-arm must be draped repeatedly throughout the surgical case. The current, un-standardized, practice employs draping procedures which violate the Association of peri-Operative Registered Nurses (AORN Standards and Recommended Practices, waste time and material, and pose an increased risk for surgical site infection. Presentation of the hypothesis Use of a novel sterile C-arm drape (C-armor that maintains the integrity of the sterile field, will improve operating room efficiency and reduce surgical site infection risk factors. This reduction in risk factors may potentially reduce surgical site infections in orthopaedic surgical cases requiring repeated horizontal x-ray imaging. Testing the Hypothesis Savings in time and material and the reduction in surgical site infection risk factors afforded by using C-armor are intuitive to those skilled in the practice of orthopaedic surgery. Testing for a reduction in the number of microorganisms introduced to the surgical site by improved C-arm draping would be challenging due to the multiple confounding factors during a surgical operation. Determination of an absolute reduction in surgical site infections may be possible, but will require accounting for many confounding variables and a large study sample in order to achieve statistical significance. Implications of the Hypothesis Improved intraoperative workflow, healthcare savings and a reduction in surgical site infection risk factors will be achieved by utilizing a standardized and safe method of sterile field maintenance during intra-operative horizontal plane fluoroscopy.

  19. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  20. Real-time image-based B-mode ultrasound image simulation of needles using tensor-product interpolation.

    Science.gov (United States)

    Zhu, Mengchen; Salcudean, Septimiu E

    2011-07-01

    In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.

  1. Intra-fraction motion of the prostate is a random walk

    Science.gov (United States)

    Ballhausen, H.; Li, M.; Hegemann, N.-S.; Ganswindt, U.; Belka, C.

    2015-01-01

    A random walk model for intra-fraction motion has been proposed, where at each step the prostate moves a small amount from its current position in a random direction. Online tracking data from perineal ultrasound is used to validate or reject this model against alternatives. Intra-fraction motion of a prostate was recorded by 4D ultrasound (Elekta Clarity system) during 84 fractions of external beam radiotherapy of six patients. In total, the center of the prostate was tracked for 8 h in intervals of 4 s. Maximum likelihood model parameters were fitted to the data. The null hypothesis of a random walk was tested with the Dickey-Fuller test. The null hypothesis of stationarity was tested by the Kwiatkowski-Phillips-Schmidt-Shin test. The increase of variance in prostate position over time and the variability in motility between fractions were analyzed. Intra-fraction motion of the prostate was best described as a stochastic process with an auto-correlation coefficient of ρ = 0.92  ±  0.13. The random walk hypothesis (ρ = 1) could not be rejected (p = 0.27). The static noise hypothesis (ρ = 0) was rejected (p test rejected the null hypothesis ρ = 1 in 25% to 32% of cases. On average, the Kwiatkowski-Phillips-Schmidt-Shin test rejected the null hypothesis ρ = 0 with a probability of 93% to 96%. The variance in prostate position increased linearly over time (r2 = 0.9  ±  0.1). Variance kept increasing and did not settle at a maximum as would be expected from a stationary process. There was substantial variability in motility between fractions and patients with maximum aberrations from isocenter ranging from 0.5 mm to over 10 mm in one patient alone. In conclusion, evidence strongly suggests that intra-fraction motion of the prostate is a random walk and neither static (like inter-fraction setup errors) nor stationary (like a cyclic motion such as breathing, for example). The prostate tends to drift away from the isocenter during a fraction, and

  2. Intra-fraction motion of the prostate is a random walk

    International Nuclear Information System (INIS)

    Ballhausen, H; Li, M; Hegemann, N-S; Ganswindt, U; Belka, C

    2015-01-01

    A random walk model for intra-fraction motion has been proposed, where at each step the prostate moves a small amount from its current position in a random direction. Online tracking data from perineal ultrasound is used to validate or reject this model against alternatives. Intra-fraction motion of a prostate was recorded by 4D ultrasound (Elekta Clarity system) during 84 fractions of external beam radiotherapy of six patients. In total, the center of the prostate was tracked for 8 h in intervals of 4 s. Maximum likelihood model parameters were fitted to the data. The null hypothesis of a random walk was tested with the Dickey–Fuller test. The null hypothesis of stationarity was tested by the Kwiatkowski–Phillips–Schmidt–Shin test. The increase of variance in prostate position over time and the variability in motility between fractions were analyzed. Intra-fraction motion of the prostate was best described as a stochastic process with an auto-correlation coefficient of ρ = 0.92  ±  0.13. The random walk hypothesis (ρ = 1) could not be rejected (p = 0.27). The static noise hypothesis (ρ = 0) was rejected (p < 0.001). The Dickey–Fuller test rejected the null hypothesis ρ = 1 in 25% to 32% of cases. On average, the Kwiatkowski–Phillips–Schmidt–Shin test rejected the null hypothesis ρ = 0 with a probability of 93% to 96%. The variance in prostate position increased linearly over time (r 2 = 0.9  ±  0.1). Variance kept increasing and did not settle at a maximum as would be expected from a stationary process. There was substantial variability in motility between fractions and patients with maximum aberrations from isocenter ranging from 0.5 mm to over 10 mm in one patient alone. In conclusion, evidence strongly suggests that intra-fraction motion of the prostate is a random walk and neither static (like inter-fraction setup errors) nor stationary (like a cyclic motion such as breathing, for example). The prostate tends to

  3. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  4. Avances en las técnicas ecográficas para el diagnóstico y estadiaje del cáncer de próstata. Elastografía, ecografía doppler, contrastes ecográficos, métodos de cuantificación ecográfica y fusión con resonancia magnética nuclear

    NARCIS (Netherlands)

    Westendarp, M.; Postema, A.; de la Rosette, J.J.M.C.; Wijkstra, H.; Laguna, M.P.

    OBJECTIVES: Transrectal ultrasound-guided prostate biopsy remains the gold standard in the diagnosis of prostate cancer. Various Ultrasound modalities have been proposed to increase the cancer detection rate. Our purpose is to evaluate each of these methods , and to present its current literature

  5. Digital rectal examination and transrectal ultrasonography in staging of rectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1994-01-01

    Staging of rectal carcinoma before surgical treatment was performed in a prospective blind study, comparing digital rectal exploration and transrectal linear ultrasonography (TRUS) with the resulting pathological examination. TRUS underestimated depth of penetration in 3 of 33 patients...... and overestimation resulted in 9 of 74. The figures for digital examination were 5 of 18 and 20 of 76, respectively. Penetration of the rectal wall was correctly identified in 56 of 61 patients by digital examination and in 59 of 61 by TRUS. Specimens without penetration of the rectal wall were identified in 26...

  6. A new method for temperature-field reconstruction during ultrasound-monitored cryosurgery using potential-field analogy.

    Science.gov (United States)

    Thaokar, Chandrajit; Rossi, Michael R; Rabin, Yoed

    2016-02-01

    The current study aims at developing computational tools in order to gain information about the thermal history in areas invisible to ultrasound imaging during cryosurgery. This invisibility results from the high absorption rate of the ultrasound energy by the frozen region, which leads to an apparent opacity in the cryotreated area and a shadow behind it. A proof-of-concept for freezing-front estimation is demonstrated in the current study, using the new potential-field analogy method (PFAM). This method is further integrated with a recently developed temperature-field reconstruction method (TFRM) to estimate the temperature distribution within the frozen region. This study uses prostate cryosurgery as a developmental model and trans-rectal ultrasound imaging as a choice of practice. Results of this study indicate that the proposed PFAM is a viable and computationally inexpensive solution to estimate the extent of freezing in the acoustic shadow region. Comparison of PFAM estimations and experimental data shows an average mismatch of less than 2 mm in freezing-front location, which is comparable to the uncertainty in ultrasound imaging. Comparison of the integrated PFAM + TFRM scheme with a full-scale finite-elements analysis (FEA) indicates an average mismatch of 0.9 mm for the freezing front location and 0.1 mm for the lethal temperature isotherm of -45 °C. Comparison of the integrated PFAM + TFRM scheme with experimental temperature measurements show a difference in the range of 2 °C and 6 °C for selected points of measurement. Results of this study demonstrate the integrated PFAM + TFRM scheme as a viable and computationally inexpensive means to gain information about the thermal history in the frozen region during ultrasound-monitored cryosurgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Intra­‑abdominal adhesions in ultrasound. Part I: The visceroperitoneal bordeline, anatomy and the method of examination

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2012-12-01

    Full Text Available It needs to be emphasized that ultrasonography is a primary test performed in order to evaluate the abdominal wall and structures located in their vicinity. It allows for the determination of the anatomy and lesions in this localization. Thorough knowledge con‑ cerning the ultrasound anatomy of the tested structures constitutes a basis of all diagnos‑ tic successes. Therefore, this part of the article is devoted to this subject matter. The pos‑ sibility to diagnose intra-abdominal adhesions with ultrasound is underestimated and rarely used. The aim of this paper is to discuss and document the ultrasound anatomy of the posterior surface of the abdominal wall as well as to present techniques directed at the detection of adhesions, in particular the visceroperitoneal ones. The posterior surface of the abdominal wall constitutes an extensive tissue area of complex structure, with folds and ligaments surrounded by various amounts of the epiperitoneal fat. In some places, this tissue separates the components of the fascia and peritoneum complex. The ultra‑ sound manifestation of this complex is two hyperechogenic lines placed parallelly to each other in the places where they are not separated by the accumulated adipose tissue. Another factor which separates the peritoneum from the viscera is of dynamic character. It is a so-called visceral slide induced by easy or deep breathing. Its size should not be lower than 1 cm and the deflections gradually and symmetrically diminish from the epi‑ gastric to hypogastric region. Last but not least, the evaluation of the reciprocal relation of the abdominal wall with viscera may be aided by rhythmical manual compressions on the abdominal wall (ballottement sign performed below the applied ultrasound trans‑ ducer. During this test, the size of the visceral slide in relation to the abdominal wall is observed. The maneuver is usually performed in uncooperative patients or those with shallow breath. The

  8. Intensification of extraction of curcumin from Curcuma amada using ultrasound assisted approach: Effect of different operating parameters.

    Science.gov (United States)

    Shirsath, S R; Sable, S S; Gaikwad, S G; Sonawane, S H; Saini, D R; Gogate, P R

    2017-09-01

    Curcumin, a dietary phytochemical, has been extracted from rhizomes of Curcuma amada using ultrasound assisted extraction (UAE) and the results compared with the conventional extraction approach to establish the process intensification benefits. The effect of operating parameters such as type of solvent, extraction time, extraction temperature, solid to solvent ratio, particle size and ultrasonic power on the extraction yield have been investigated in details for the approach UAE. The maximum extraction yield as 72% was obtained in 1h under optimized conditions of 35°C temperature, solid to solvent ratio of 1:25, particle size of 0.09mm, ultrasonic power of 250W and ultrasound frequency of 22kHz with ethanol as the solvent. The obtained yield was significantly higher as compared to the batch extraction where only about 62% yield was achieved in 8h of treatment. Peleg's model was used to describe the kinetics of UAE and the model showed a good agreement with the experimental results. Overall, ultrasound has been established to be a green process for extraction of curcumin with benefits of reduction in time as compared to batch extraction and the operating temperature as compared to Soxhlet extraction. Copyright © 2017. Published by Elsevier B.V.

  9. SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

    International Nuclear Information System (INIS)

    Williams, C; Crowley, E; Wolfgang, J

    2016-01-01

    Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on

  10. SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Williams, C [Brigham and Women’s Hospital & Dana Farber Cancer Institute, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Crowley, E; Wolfgang, J [Harvard Medical School, Boston, MA (United States); Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on

  11. Intra-operative X-ray diagnostics in the detection and localization of residual concretions in the kidney

    International Nuclear Information System (INIS)

    Soekeland, J.; Degenhardt, W.

    1979-01-01

    Problems of intra-operative X-ray diagnostics in the detection and localization of residual concretions in the kidney are discussed, together with the limitations of image-intensifier techniques, automatic exposure control, and the use of modified dental X-ray equipment. A technique using a film-screen combination and X-ray tube designed for mammography is discussed, together with its applications and possible future development. (Auth.)

  12. Serial transrectal ultrasonography for monitoring the reproductive activity of the Asiatic black bear (Ursus thibetanus ussuricus).

    Science.gov (United States)

    Kang, H G; Jeong, D H; Yang, J J; Lee, B K; Kong, J K; Lee, J W; Kim, I H

    2015-02-01

    This study evaluated the structural changes in the reproductive tract of Asiatic black bears using serial transrectal ultrasonography. In addition, the ultrasonographic observations were compared with the results of vaginal cytology and hormonal analyses. The collection of blood for hormonal analysis, vaginal cytology and transrectal ultrasonography was performed in two bears (Bears 1 and 2) from June 2011 to August 2013 without mating and in a third bear (Bear 3) from April to December 2012, allowing natural mating. Serial ultrasonographic observations showed cyclic changes in ovarian structures (e.g. emergence of small follicles, growth and ovulation of dominant follicles and corpus luteum (CL) formation) during the reproductive cycles of the three bears. The diameter of the uterine horns remained similar throughout the reproductive cycle in Bears 1 and 2, and it remained similar from April until October, but an enlargement containing foetuses was observed in Bear 3 in December. The ultrasonographic observations were consistent with the data obtained through vaginal cytology and progesterone analysis during the reproductive cycle. An average of 4.0 (±0.4) dominant follicles was observed during the oestrous stage (May-August), during which the superficial cells accounted for >90% of the total vaginal cells. In addition, the detection of an average of 2.6 (±0.2) CL was associated with increased plasma progesterone concentrations (3.0 ± 0.4 ng/ml) between June and December (near hibernation). In conclusion, serial transrectal ultrasonography demonstrated yearly oestrous (ovulation) cycles via follicular dynamics and CL formation on ovaries, accordingly with vaginal cytology and hormonal level in the Asiatic black bear. © 2014 Blackwell Verlag GmbH.

  13. Preoperative localization of endocrine pancreatic tumours by intra-arterial dynamic computed tomography

    International Nuclear Information System (INIS)

    Ahlstroem, H.; Magnusson, A.; Grama, D.; Eriksson, B.; Oeberg, K.; Loerelius, L.E.; Akademiska Sjukhuset, Uppsala; Akademiska Sjukhuset, Uppsala

    1990-01-01

    Eleven patients with biochemically confirmed endocrine pancreatic tumours were examined with intra-arterial (i.a.) dynamic computed tomography (CT) and angiography preoperatively. Seven of the patients suffered from the multiple endocrine neoplasia type 1 (MEN-1) syndrome. All patients were operated upon and surgical palpation and ultrasound were the peroperative localization methods. Of the 33 tumours which were found at histopathologic analysis of the resected specimens in the 11 patients, 7 tumours in 7 patients were correctly localized by both i.a. dynamic CT and angiography. Six patients with MEN-1 syndrome had multiple tumours and this group of patients together had 28 tumours, of which 5 (18%) were localized preoperatively by both CT and angiography. I.a. dynamic CT, with the technique used by us, does not seem to improve the localization of endocrine pancreatic tumours, especially in the rare group of MEN-1 patients, as compared with angiography. (orig.)

  14. Avances en las Técnicas Ecográficas para el diagnóstico y estadiaje del cáncer de próstata. Elastografía, Ecografía doppler, Contrastes Ecográficos, Métodos de Cuantificación ecográfica y fusión con Resonancia Magnética Nuclear

    NARCIS (Netherlands)

    Westendarp, M.; Postema, A.; de la Rosette, J. J. M. C.; Wijkstra, H.; Laguna, M. P.

    2015-01-01

    Transrectal ultrasound-guided prostate biopsy remains the gold standard in the diagnosis of prostate cancer. Various Ultrasound modalities have been proposed to increase the cancer detection rate. Our purpose is to evaluate each of these methods , and to present its current literature and clinical

  15. Intra-arterial digital subtraction angiography in the diagnosis of insulinomas

    International Nuclear Information System (INIS)

    Moulopoulou, A.; Vlahos, L.

    1988-01-01

    Two cases of surgically proved benign insulinoma of the pancreas were correctly localized with intra-arterial digital subtraction angiography (IA-DSA) of the coeliac and the superior mesenteric artery, while the respective dynamic computed tomography (CT) and ultrasound (US) examinations were negative. In a third case of organic hyperinsulinism, IA-DSA, CT and US suggested a pancreatic islet-cell tumor, but the histological examination of the resected suspicious area was that of focal hyperplasia. 17 refs.; 3 figs

  16. 4D ultrasound and 3D MRI registration of beating heart

    International Nuclear Information System (INIS)

    Herlambang, N.; Matsumiya, K.; Masamune, K.; Dohi, T.; Liao, H.; Tsukihara, H.; Takamoto, S.

    2007-01-01

    To realize intra-cardiac surgery without cardio-pulmonary bypass, a medical imaging technique with both high image quality and data acquisition rate that is fast enough to follow heart beat movements is required. In this research, we proposed a method that utilized the image quality of MRI and the speed of ultrasound. We developed a 4D image reconstruction method using image registration of 3D MRI and 4D ultrasound images. The registration method consists of rigid registration between 3D MRI and 3D ultrasound with the same heart beat phase, and non-rigid registration between 3D ultrasound images from different heart beat phases. Non-rigid registration was performed with B-spline based registration using variable spring model. In phantom experiment using balloon phantom, registration accuracy was less than 2 mm for total heart volume variation range of 10%. We applied our registration method on 3D MRI and 4D ultrasound images of a volunteer's beating heart data and confirmed through visual observation that heart beat pattern was well reproduced. (orig.)

  17. Effects and Mechanisms of Low-Intensity Pulsed Ultrasound for Chronic Prostatitis and Chronic Pelvic Pain Syndrome

    Directory of Open Access Journals (Sweden)

    Guiting Lin

    2016-07-01

    Full Text Available Chronic Prostatitis/Chronic Pelvic Pain Syndrome (CP/CPPS is one of the most common urologic diseases, and no curative treatments have been identified. Low-intensity pulsed ultrasound (LIPUS has been successfully used in promoting tissue healing, inhibiting inflammation and pain, differentiating stem cells, and stimulating nerve regeneration/muscle regeneration, as well as enhancing angiogenesis. Very recently, LIPUS has been proven an effective approach for CP/CPPS. This review summarizes the possible mechanisms responsible for the therapeutic effect of LIPUS for CP/CPPS. To search publications relevant to the topics of this review, the search engine for life sciences of Entrez was used. We reviewed the available evidence from 1954 through 2015 concerning LIPUS for CP/CPPS. According to the literature, both transrectal and transperineal approaches of LIPUS are effective for CP/CPPS.

  18. Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

    Science.gov (United States)

    Johnson, Garrett G R J; Zeiler, Frederick A; Unger, Bertram; Hansen, Gregory; Karakitsos, Dimitrios; Gillman, Lawrence M

    2016-12-01

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland-Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland-Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.

  19. The effect of post-traumatic-stress-disorder on intra-operative analgesia in a veteran population during cataract procedures carried out using retrobulbar or topical anesthesia: a retrospective study.

    Science.gov (United States)

    Rapoport, Yuna; Wayman, Laura L; Chomsky, Amy S

    2017-06-07

    A growing proportion of veterans treated at the Veterans Health Administration (VA) have a history of post-traumatic-stress-disorder (PTSD), and there exists a higher rate of PTSD amongst veterans than the general population. The purpose of this study is to determine the correlation between PTSD and intra-operative analgesia, intra-operative time, and anesthesia type for cataract surgery in a veteran population. Secondary objectives are to determine if patient age, and first or second eye surgery affect intra-operative pain control or are correlated with type of anesthesia modality. A retrospective study of 330 cataract surgeries performed by resident physicians between January and September 2012 at the Veterans Affairs Medical Center Tennessee Valley Healthcare System, Nashville and Murfreesboro Campuses was completed. Three hundred and thirty veteran patients were selected if their cataract surgery was performed between January and September 2012. Combined cases were excluded. The primary outcome evaluated was intra-operative analgesia. Secondary outcomes included history of post-traumatic-stress-disorder, anesthesia type, first or second eye, pain control, intra-operative heart rate and blood pressure, age, and case complexity. Data was analyzed using an unpaired two-sample Welch's t-test assuming unequal variance and Z test of comparison of proportions. Patients with post-traumatic-stress-disorder reported higher pain scores, had longer operative times, and were more likely to have received a retrobulbar block. Operative time was not associated with an increased pain score, irrespective of anesthesia type, when controlled for PTSD. Complex cases had longer operative times, more sedation, and higher pain scores. P < 0.05 was used consistently. Post-traumatic stress disorder and anxiety are more prevalent in the veteran population. Our data suggests that a history of post-traumatic-stress-disorder was correlated with higher pain scores, longer operative times

  20. Ultrasound-mediated interferon β gene transfection inhibits growth of malignant melanoma

    International Nuclear Information System (INIS)

    Yamaguchi, Kazuki; Feril, Loreto B.; Tachibana, Katsuro; Takahashi, Akira; Matsuo, Miki; Endo, Hitomi; Harada, Yoshimi; Nakayama, Juichiro

    2011-01-01

    Highlights: → Successful ultrasound-mediated transfection of melanoma (C32) cells with IFN-β genes both in vitro and in vivo. → Ultrasound-mediated IFN-β transfection inhibited proliferation of melanoma cells in vitro. → Ultrasound-mediated IFN-β transfection inhibited melanoma tumor growth in vivo. -- Abstract: We investigated the effects of ultrasound-mediated transfection (sonotransfection) of interferon β (IFN-β) gene on melanoma (C32) both in vitro and in vivo. C32 cells were sonotransfected with IFN-β in vitro. Subcutaneous C32 tumors in mice were sonicated weekly immediately after intra-tumor injection with IFN-β genes mixed with microbubbles. Successful sonotransfection with IFN-β gene in vitro was confirmed by ELISA, which resulted in C32 growth inhibition. In vivo, the growth ratio of tumors transfected with IFN-β gene was significantly lower than the other experimental groups. These results may lead to a new method of treatment against melanoma and other hard-to-treat cancers.

  1. Audit of ultrasound and decision to operate in groin pain of unknown aetiology with ultrasound technique explained

    International Nuclear Information System (INIS)

    Depasquale, R.; Landes, C.; Doyle, G.

    2009-01-01

    Aim: To determine the ability of a groin ultrasound service to identify inguinal/femoral hernias in patients with groin pain and equivocal clinical signs, and to evaluate the number of positive cases undergoing surgery. Methods and materials: A retrospective review of 243 examinations performed during the period January 2000 to June 2004 was undertaken. The referral information, as well as details of the examination and subsequent follow-up, were obtained through our hospital/radiological information system. Results: Of 243 patients, 92 (38%) were referrals from general practitioners and 151 (62%) were hospital referrals. The examinations were performed by radiology consultants or specialist registrars, the former accounting for 228 examinations (94%). The age range of the patients was 3 months to 88 years (mean age = 48.7), with a male to female ratio of 3.2:1. One hundred and forty-three examinations were negative for hernias. Two of these patients underwent groin explorations and were found to be normal. The rest were discharged and none returned with related complaints. Ninety-four examinations (39%) were positive for hernias, as a result of which 62 patients underwent surgery. Of these, only four were found to be false-positives giving a positive predictive value of 94% in operated patients. Three scans were equivocal, and three were positive for other conditions. Conclusion: In patients with equivocal clinical signs, groin ultrasound is a useful tool for identifying hernias, and therefore, aids surgical management.

  2. Audit of ultrasound and decision to operate in groin pain of unknown aetiology with ultrasound technique explained

    Energy Technology Data Exchange (ETDEWEB)

    Depasquale, R. [Countess of Chester Hospital NHS Foundation Trust, Countess of Chester Health Park, Chester, Cheshire (United Kingdom)], E-mail: ruben.depasquale@gmail.com; Landes, C.; Doyle, G. [Countess of Chester Hospital NHS Foundation Trust, Countess of Chester Health Park, Chester, Cheshire (United Kingdom)

    2009-06-15

    Aim: To determine the ability of a groin ultrasound service to identify inguinal/femoral hernias in patients with groin pain and equivocal clinical signs, and to evaluate the number of positive cases undergoing surgery. Methods and materials: A retrospective review of 243 examinations performed during the period January 2000 to June 2004 was undertaken. The referral information, as well as details of the examination and subsequent follow-up, were obtained through our hospital/radiological information system. Results: Of 243 patients, 92 (38%) were referrals from general practitioners and 151 (62%) were hospital referrals. The examinations were performed by radiology consultants or specialist registrars, the former accounting for 228 examinations (94%). The age range of the patients was 3 months to 88 years (mean age = 48.7), with a male to female ratio of 3.2:1. One hundred and forty-three examinations were negative for hernias. Two of these patients underwent groin explorations and were found to be normal. The rest were discharged and none returned with related complaints. Ninety-four examinations (39%) were positive for hernias, as a result of which 62 patients underwent surgery. Of these, only four were found to be false-positives giving a positive predictive value of 94% in operated patients. Three scans were equivocal, and three were positive for other conditions. Conclusion: In patients with equivocal clinical signs, groin ultrasound is a useful tool for identifying hernias, and therefore, aids surgical management.

  3. Estimation of sensitivity and specificity of pregnancy diagnosis using transrectal ultrasonography and ELISA for pregnancy-associated glycoprotein in dairy cows using a Bayesian latent class model.

    Science.gov (United States)

    Shephard, R W; Morton, J M

    2018-01-01

    To determine the sensitivity (Se) and specificity (Sp) of pregnancy diagnosis using transrectal ultrasonography and an ELISA for pregnancy-associated glycoprotein (PAG) in milk, in lactating dairy cows in seasonally calving herds approximately 85-100 days after the start of the herd's breeding period. Paired results were used from pregnancy diagnosis using transrectal ultrasonography and ELISA for PAG in milk carried out approximately 85 and 100 days after the start of the breeding period, respectively, from 879 cows from four herds in Victoria, Australia. A Bayesian latent class model was used to estimate the proportion of cows pregnant, the Se and Sp of each test, and covariances between test results in pregnant and non-pregnant cows. Prior probability estimates were defined using beta distributions for the expected proportion of cows pregnant, Se and Sp for each test, and covariances between tests. Markov Chain Monte Carlo iterations identified posterior distributions for each of the unknown variables. Posterior distributions for each parameter were described using medians and 95% probability (i.e. credible) intervals (PrI). The posterior median estimates for Se and Sp for each test were used to estimate positive predictive and negative predictive values across a range of pregnancy proportions. The estimate for proportion pregnant was 0.524 (95% PrI = 0.485-0.562). For pregnancy diagnosis using transrectal ultrasonography, Se and Sp were 0.939 (95% PrI = 0.890-0.974) and 0.943 (95% PrI = 0.885-0.984), respectively; for ELISA, Se and Sp were 0.963 (95% PrI = 0.919-0.990) and 0.870 (95% PrI = 0.806-0.931), respectively. The estimated covariance between test results was 0.033 (95% PrI = 0.008-0.046) and 0.035 (95% PrI = 0.018-0.078) for pregnant and non-pregnant cows, respectively. Pregnancy diagnosis results using transrectal ultrasonography had a higher positive predictive value but lower negative predictive value than results from the

  4. Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy

    NARCIS (Netherlands)

    Ven, W.J.M. van de; Hu, Y.; Barentsz, J.O.; Karssemeijer, N.; Barratt, D.; Huisman, H.J.

    2015-01-01

    Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based

  5. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Kulig, J; Szybinski, P; Mikolajczak, R; Pach, D; Sowa-Staszczak, A; Fröss-Baron, K; Huszno, B

    2007-10-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.

  6. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Kulig, J.; Szybinski, P.; Mikolajczak, R.; Pach, D.; Sowa-Staszczak, A.; Froess-Baron, K.; Huszno, B.

    2007-01-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue ''marked'' by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [ 99m Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [ 99m Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [ 99m Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [ 99m Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology. (orig.)

  7. Transrectal ultrasound: Diagnosis of prostate cancer by a new biplane US-guided biopsy technique. Comparison of thin-needle cytology and histology with large-core biopsy

    International Nuclear Information System (INIS)

    Lee, F.; Littrup, P.; McLeary, R.; Kumasaka, G.; Borlaza, G.; McHugh, T.; Soiderer, M.; Roi, L.

    1986-01-01

    A new transperineal biopsy technique was developed that uses biplane transrectal US guidance for needle placement into anechoic-hypoechoic lesions thought to indicate prostate cancer (n = 83). The results of histologic studies on biopsy material obtained with a 22-gauge needle and of aspiration histologic studies on biopsy material obtained with a 19-gauge needle were compared with results of histologic studies on material obtained with a 14-gauge needle. When sufficient tissue was obtained, the positive biopsy yield was 61% by cytology and 58% by histology; the combined yield was 61%. A limited study ( n = 21) of histologic findings in biopsy material obtained with 19-gauge and 14-gauge needles showed equivalent diagnostic results. Sixty-seven percent of the biopsies were of lesions less than 1.5 cm in diameter, and 57% (13 of 23) of the biopsy-proved cancers in this group were either nonpalpable or only mildly suspicious on digital rectal examination

  8. Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

    Science.gov (United States)

    Hurst, Victor; Dulchavsky, Scott; Garcia, Kathleen; Sargsyan, Ashot; Ebert, Doug

    2009-01-01

    To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

  9. Efficacy of a single ultrasound-guided injection for the treatment of hip osteoarthritis.

    LENUS (Irish Health Repository)

    Atchia, Ismaël

    2011-01-01

    Intra-articular injection is effective for osteoarthritis, but the best single injection strategy is not known, nor are there established predictors of response. The objectives of this study were to assess and predict response to a single ultrasound-guided injection in moderate to severe hip osteoarthritis.

  10. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.

    Science.gov (United States)

    Törnqvist, P; Dias, N; Sonesson, B; Kristmundsson, T; Resch, T

    2015-04-01

    Re-interventions after endovascular abdominal aortic aneurysm repair (EVAR) are common and therefore a strict imaging follow up protocol is required. The purpose of this study was to evaluate whether cone beam computed tomography (CBCT) can detect intra-operative complications and to compare this with angiography and the 1 month CT follow up (computed tomography angiography [CTA]). Fifty-one patients (44 men) were enrolled in a prospective trial. Patients underwent completion angiography and CBCT during infrarenal EVAR. Contrast was used except when pre-operative renal insufficiency was present or if the maximum contrast dose threshold was reached. CBCT reconstruction included the top of the stent graft to the iliac bifurcation. Endoleaks, kinks, or compressions were recorded. CBCT was technically successful in all patients. Twelve endoleaks were detected on completion digital subtraction angiography (CA). CBCT detected 4/5 type 1 endoleaks, but only one type 2 endoleak. CTA identified eight type 2 endoleaks and one residual type I endoleak. Two cases of stent compression were seen on CA. CBCT revealed five stent compressions and one kink, which resulted in four intra-operative adjunctive manoeuvres. CTA identified all cases of kinks or compressions that were left untreated. Two of them were corrected later. No additional kinks/compressions were found on CTA. Groin closure consisted of 78 fascia sutures, nine cut downs, and 11 percutaneous sutures. Seven femoral artery pseudoaneurysms (<1 cm) were detected on CTA, but no intervention was needed. CA is better than CBCT in detecting and categorizing endoleaks but CBCT (with or without contrast) is better than CA for detection of kinks or stentgraft compression. CTA plus CBCT identified all significant complications noted on the 1 month follow up CTA. The use of intra-operative CA and CBCT could replace early CTA after standard EVAR thus reducing overall radiation and contrast use. Technical development might further

  11. TAX TREATMENT SPECIFIC TO INTRA COMMUNITY COMMERCIAL BUSINESS TRANSACTIONS - ACQUISITION AND INTRA-COMMUNITY SUPPLY OF GOODS

    Directory of Open Access Journals (Sweden)

    Paliu -Popa Lucia

    2009-11-01

    Full Text Available Romania's accession to the European Union has imposed harmonize national legislation with Community law, registering significant changes in the tax area, particularly on value added tax. In order to determine the person liable to pay value added tax, related to intra-community commercial transactions, must to clarify tax matters for those operations. Given the complexity of intra-community commercial transactions and their taxation, in the following issues we will address the intra-community trade in goods, with reference to specific tax treatment of supplies and intra-community acquisitions of goods. To do this we will consider more specific situations that arise in trade relationship between EU Member States, examples that will allow us to draw some conclusions on tax matters arising in intracommunity commercial relationship

  12. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  13. Potential predictors for the amount of intra-operative brain shift during deep brain stimulation surgery

    Science.gov (United States)

    Datteri, Ryan; Pallavaram, Srivatsan; Konrad, Peter E.; Neimat, Joseph S.; D'Haese, Pierre-François; Dawant, Benoit M.

    2011-03-01

    A number of groups have reported on the occurrence of intra-operative brain shift during deep brain stimulation (DBS) surgery. This has a number of implications for the procedure including an increased chance of intra-cranial bleeding and complications due to the need for more exploratory electrodes to account for the brain shift. It has been reported that the amount of pneumocephalus or air invasion into the cranial cavity due to the opening of the dura correlates with intraoperative brain shift. Therefore, pre-operatively predicting the amount of pneumocephalus expected during surgery is of interest toward accounting for brain shift. In this study, we used 64 DBS patients who received bilateral electrode implantations and had a post-operative CT scan acquired immediately after surgery (CT-PI). For each patient, the volumes of the pneumocephalus, left ventricle, right ventricle, third ventricle, white matter, grey matter, and cerebral spinal fluid were calculated. The pneumocephalus was calculated from the CT-PI utilizing a region growing technique that was initialized with an atlas-based image registration method. A multi-atlas-based image segmentation method was used to segment out the ventricles of each patient. The Statistical Parametric Mapping (SPM) software package was utilized to calculate the volumes of the cerebral spinal fluid (CSF), white matter and grey matter. The volume of individual structures had a moderate correlation with pneumocephalus. Utilizing a multi-linear regression between the volume of the pneumocephalus and the statistically relevant individual structures a Pearson's coefficient of r = 0.4123 (p = 0.0103) was found. This study shows preliminary results that could be used to develop a method to predict the amount of pneumocephalus ahead of the surgery.

  14. Inter-rater reliability in the classification of supraspinatus tendon tears using 3D ultrasound – a question of experience?

    Directory of Open Access Journals (Sweden)

    Giorgio Tamborrini

    2016-09-01

    Full Text Available Background: Three-dimensional (3D ultrasound of the shoulder is characterized by a comparable accuracy to two-dimensional (2D ultrasound. No studies investigating 2D versus 3D inter-rater reliability in the detection of supraspinatus tendon tears taking into account the level of experience of the raters have been carried out so far. Objectives: The aim of this study was to determine the inter-rater reliability in the analysis of 3D ultrasound image sets of the supraspinatus tendon between sonographer with different levels of experience. Patients and methods: Non-interventional, prospective, observational pilot study of 2309 images of 127 adult patients suffering from unilateral shoulder pain. 3D ultrasound image sets were scored by three raters independently. The intra-and interrater reliabilities were calculated. Results: There was an excellent intra-rater reliability of rater A in the overall classification of supraspinatus tendon tears (2D vs 3D κ = 0.892, pairwise reliability 93.81%, 3D scoring round 1 vs 3D scoring round 2 κ = 0.875, pairwise reliability 92.857%. The inter-rater reliability was only moderate compared to rater B on 3D (κ = 0.497, pairwise reliability 70.95% and fair compared to rater C (κ = 0.238, pairwise reliability 42.38%. Conclusions: The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer. Experience in 2D ultrasound does not seem to be sufficient for the analysis of 3D ultrasound imaging sets. Therefore, for a 3D ultrasound analysis new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.

  15. Ultrasound evaluation of the abductor hallucis muscle: Reliability study

    Directory of Open Access Journals (Sweden)

    Hing Wayne A

    2008-09-01

    Full Text Available Abstract Background The Abductor hallucis muscle (AbdH plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Results The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99; medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97 and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99. Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98; medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96 and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88. Conclusion Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.

  16. Pre-Operative Prediction of Advanced Prostatic Cancer Using Clinical Decision Support Systems: Accuracy Comparison between Support Vector Machine and Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Youn; Moon, Sung Kyoung; Hwang, Sung Il; Sung, Chang Kyu; Cho, Jeong Yeon; Kim, Seung Hyup; Lee, Hak Jong [Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Dae Chul [National Cancer Center, Ilsan (Korea, Republic of); Lee, Ji Won [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2011-10-15

    The purpose of the current study was to develop support vector machine (SVM) and artificial neural network (ANN) models for the pre-operative prediction of advanced prostate cancer by using the parameters acquired from transrectal ultrasound (TRUS)-guided prostate biopsies, and to compare the accuracies between the two models. Five hundred thirty-two consecutive patients who underwent prostate biopsies and prostatectomies for prostate cancer were divided into the training and test groups (n = 300 versus n 232). From the data in the training group, two clinical decision support systems (CDSSs-[SVM and ANN]) were constructed with input (age, prostate specific antigen level, digital rectal examination, and five biopsy parameters) and output data (the probability for advanced prostate cancer [> pT3a]). From the data of the test group, the accuracy of output data was evaluated. The areas under the receiver operating characteristic (ROC) curve (AUC) were calculated to summarize the overall performances, and a comparison of the ROC curves was performed (p < 0.05). The AUC of SVM and ANN is 0.805 and 0.719, respectively (p = 0.020), in the pre-operative prediction of advanced prostate cancer. Te performance of SVM is superior to ANN in the pre-operative prediction of advanced prostate cancer.

  17. Ultrasound techniques in the evaluation of the mediastinum, part I

    DEFF Research Database (Denmark)

    Dietrich, Christoph Frank; Annema, Jouke Tabe; Clementsen, Paul

    2015-01-01

    Ultrasound imaging has gained importance in pulmonary medicine over the last decades including conventional transcutaneous ultrasound (TUS), endoscopic ultrasound (EUS), and endobronchial ultrasound (EBUS). Mediastinal lymph node staging affects the management of patients with both operable and i...

  18. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  19. Ultrasound assisted synthesis of stable oil in milk emulsion: Study of operating parameters and scale-up aspects.

    Science.gov (United States)

    Patil, Leena; Gogate, Parag R

    2018-01-01

    In the present work, application of ultrasound and stirring individually or in combination for improved emulsification of turmeric oil in skimmed milk has been investigated. The effect of different operating parameters/strategies such as addition of surfactant, sodium dodecyl sulfate (SDS), at different concentrations, quantity of oil phase, applied power, sonication time and duty cycle on the droplet size have been investigated. The stability of emulsion was analyzed in terms of the fraction of the emulsion that remains stable for a period of 28days. Optimized set of major emulsification process variables has been used at higher emulsion volumes. The effectiveness of treatment approach was analyzed based on oil droplet size, energy density and the time required for the formation of stable emulsion. It was observed that the stable emulsion at 50mL capacity with mean droplet diameter of about 235.4nm was obtained with the surfactant concentration of 5mg/mL, 11% of rated power (power density: 0.31W/mL) and irradiation time of 5min. The emulsion stability was higher in the case of ultrasound assisted approach as compared to the stirring. For the preparation of stable emulsion at 300mL capacity, it was observed that the sequential approach, i.e., stirring followed by ultrasound, gave lower mean droplet diameter (232.6nm) than the simultaneous approach, i.e., ultrasound and stirring together (257.9nm). However, the study also revealed that the simultaneous approach required very less time (15min) to synthesize stable emulsion as compared to the sequential approach (30min stirring and 60min ultrasound). It was successfully demonstrated that the ultrasound-assisted emulsification in the presence of SDS could be used for the preparation of stable turmeric oil-dairy emulsions, also providing insights into the role of SDS in increasing the stability of emulsions and of ultrasound in giving lower droplet sizes. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Hazard analysis and critical control point (HACCP) for an ultrasound food processing operation.

    Science.gov (United States)

    Chemat, Farid; Hoarau, Nicolas

    2004-05-01

    Emerging technologies, such as ultrasound (US), used for food and drink production often cause hazards for product safety. Classical quality control methods are inadequate to control these hazards. Hazard analysis of critical control points (HACCP) is the most secure and cost-effective method for controlling possible product contamination or cross-contamination, due to physical or chemical hazard during production. The following case study on the application of HACCP to an US food-processing operation demonstrates how the hazards at the critical control points of the process are effectively controlled through the implementation of HACCP.

  1. Role of ultrasound in rotator cuff tears

    International Nuclear Information System (INIS)

    Siddiqi, H.A.; Mirza, T.

    2010-01-01

    The study was designed to evaluate the efficacy of ultrasound in rotator cuff tears and to compare it with MRI. Total number of patients was thirty. All of these were above thirty years of age and were referred by clinicians, with shoulder pain for diagnostic workup. Post operative patients were excluded. Ultrasound and Magnetic Resonance Imaging (MRI) were performed on each patient. Same operator performed ultrasound in all patients. Ultrasound (US) and Magnetic Resonance Imaging (MRI) detected equal number of full thickness tears while two partial thickness tears were missed on US. Hypoechoic defect was the most important primary sign while cortical irregularity and fluid in subacromial and subdeltroid busra were the most important secondary signs on US. US was equally effective to MRI in detection of rotator cuff tears. It should be the primary investigation because of its availability, cost effective and real time evaluation provided significant expertise is developed, as it is highly operator dependent. (author)

  2. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    Science.gov (United States)

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  3. Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm

    Directory of Open Access Journals (Sweden)

    Yang-Sub Lee

    2015-01-01

    Full Text Available Background: The aim of this study was to investigate clinical applications of mobile C-arms and consequent radiation risk, to increase medical attention on radiation protection, and to provide basic data for safe radiation use in the operating room. Materials and Methods: In this study, a total of 374 surgical operations, conducted using a portable fluoroscopic X-ray system from January to March of 2013, were analyzed. Dose summaries produced by the General Electric C-arm and data elements in digital imaging and communications in the medicine header of Ziehm C-arm, fluoroscopy time were used to obtain dose-area product (DAP and effective dose. Corresponding mean and maximum values were calculated, and the resulting data on the frequency of application, fluoroscopy time, DAP, and effective dose were compared and analyzed in terms of surgical specialty and operation types. Results: Orthopedic surgery was the most frequent with 165 cases (44.1%. The highest DAP value and effective dose were found in liver transplant among surgical specialty fields, with mean values of 2.90 ± 3.76 mGy∙m 2 and 58 ± 75.2 mSv, respectively (P = 0.0001. The highest DAP value and effective dose were observed in intra-operative mesenteric portography among types of surgery, showing mean values of 2.90 ± 3.81 mGy∙m 2 and 58.03 ± 76.24 mSv, respectively (P = 0.0001. Conclusion: Because DAP varies significantly across surgical specialties and types of operation, aggressive efforts to understand the effects of radiation dose is critical for radiation protection from intra-operative use of mobile C-arms.

  4. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  5. Manual lymphatic drainage and therapeutic ultrasound in liposuction and lipoabdominoplasty post-operative period

    Directory of Open Access Journals (Sweden)

    Igor F. B. Masson

    2014-01-01

    Full Text Available Background: Physiotherapy in the plastic surgery post-operative (PO is essential to provide means for an adequate and fast recovery as it restores function through the use of physiotherapeutic procedures. Aim: The aim of the following study is to verify the effects of the association between the manual lymphatic drainage and the therapeutic ultrasound on pain, oedema and the tissue fibrosis in liposuction and lipoabdominoplasty PO. Design: This is a clinical trial prospective. Materials and Methods: Eighteen women aged between 18 and 60 years participated in this study, in the late PO period following lipoabdominoplasty or liposuction in the abdomen, flanks and lower trunk, which showed tissue fibrosis of the flanks and abdomen regions. They were divided into two groups: Liposuction group and lipoabdominoplasty group. A total of twelve sessions of therapeutic ultrasound followed by the manual lymphatic drainage were performed. The patients were assessed with regard to pain, oedema and tissue fibrosis in different moments: Initial assessment, during assessment and final assessment through the application of the protocol of evaluation of cysts fibrosis levels. Statistical Analysis: The test of equality for two proportions and the confidence interval test for mean to evaluate the distribution of variables. The significance level adopted for statistical tests was 5% (P < 0.05. Results: There was a statistically significant reduction of pain, swelling and tissue fibrosis in both groups. Conclusion: the association between manual lymphatic drainage and the therapeutic ultrasound reduced the swelling and the tissue fibrosis and made pain disappear in liposuction and lipoabdominoplasty PO period.

  6. Intraluminal ultrasound guidance of transverse laser coronary atherectomy

    Science.gov (United States)

    Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Sedlacek, Tomas; Hatch, G. F.; Gregg, Richard E.

    1990-07-01

    A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.

  7. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  8. Machine learning for medical ultrasound: status, methods, and future opportunities.

    Science.gov (United States)

    Brattain, Laura J; Telfer, Brian A; Dhyani, Manish; Grajo, Joseph R; Samir, Anthony E

    2018-04-01

    Ultrasound (US) imaging is the most commonly performed cross-sectional diagnostic imaging modality in the practice of medicine. It is low-cost, non-ionizing, portable, and capable of real-time image acquisition and display. US is a rapidly evolving technology with significant challenges and opportunities. Challenges include high inter- and intra-operator variability and limited image quality control. Tremendous opportunities have arisen in the last decade as a result of exponential growth in available computational power coupled with progressive miniaturization of US devices. As US devices become smaller, enhanced computational capability can contribute significantly to decreasing variability through advanced image processing. In this paper, we review leading machine learning (ML) approaches and research directions in US, with an emphasis on recent ML advances. We also present our outlook on future opportunities for ML techniques to further improve clinical workflow and US-based disease diagnosis and characterization.

  9. Prostate cancer

    International Nuclear Information System (INIS)

    Spera, G.

    2010-01-01

    This work is about diagnosis, treatment and monitoring of prostate cancer. The techniques used are: transrectal ultrasound, laparascopy, bone scan, chest x-ray, radiography, chemoterapy and radiotherapy

  10. Development of Flexible Capacitive Ultrasound Transducers and the Use of Ultrasound for Bone Repair

    Science.gov (United States)

    Wentzell, Scott A.

    Ultrasound is a widely applicable technique for therapy in the biomedical arena. However, conventional ultrasound transducers are not conducive for non-planar surfaces. Therefore, we developed flexible transducers capable of performing ultrasound and evaluated their use in biomedical applications. Flexible capacitive ultrasound transducers based on micrometer-thick dielectric tapes were developed and fabricated. These transducers were able to be made by hand at low-cost while still demonstrating good tolerances in center operating frequency. Intensities of up to 120 mW/cm2 were recorded and operation was dependent upon the applied AC and DC voltages along with the thickness of the dielectric insulation. These capacitive ultrasound transducers were used to stimulate MC3T3-E1 murine osteoblast cells to investigate the effects of low-frequency ultrasound on osteogenic gene expression and anabolic signaling pathways. After stimulation by 94.5 kHz continuous wave ultrasound for 20 minutes, significant increases in the activation of the Wnt signaling pathway and concentration of intracellular calcium were observed. Daily stimulation by ultrasound showed a trend of increased osteogenic gene expression across the phases of matrix deposition, maturation and calcification by osteoblasts. Finally, the heating of osteoblasts for stimulating osteoclastogenic responses was investigated. The application of increased temperatures of 42 and 47 degrees Celsius for 5 minutes showed significant increases in the RANKL/OPG ratio in media conditioned by osteoblasts. However, the altered RANKL/OPG ratio was not able to generate increases in osteoclastogenesis for RAW 264.7 murine macrophage cells culture in the condition media. This was possibly due to high overall osteoprotegerin expression, or unwanted inducement of M1 and M2 macrophage activation in the cell population. The overall work of this thesis demonstrates the development of novel capacitive transducers. These conformable

  11. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  12. Unpowered wireless transmission of ultrasound signals

    International Nuclear Information System (INIS)

    Huang, H; Paramo, D; Deshmukh, S

    2011-01-01

    This paper presents a wireless ultrasound sensing system that uses frequency conversion to convert the ultrasound signal to a microwave signal and transmit it directly without digitization. Constructed from a few passive microwave components, the sensor is able to sense, modulate, and transmit the full waveform of ultrasound signals wirelessly without requiring any local power source. The principle of operation of the unpowered wireless ultrasound sensor is described first, and this is followed by a detailed description of the implementation of the sensor and the sensor interrogation unit using commercially available antennas and microwave components. Validation of the sensing system using an ultrasound pitch–catch system and the power analysis model of the system are also presented

  13. Ultrasound characteristics of gouty tophi in the olecranon bursa and evaluation of their reproducibility

    International Nuclear Information System (INIS)

    Fernandes, Eloy A.; Lopes, Matheus G.; Mitraud, Sônia A.V.; Ferrari, Antonio J.L.; Fernandes, Artur R.C.

    2012-01-01

    Objectives: To describe the ultrasound characteristics of gouty tophi in the olecranon bursa and to evaluate their reproducibility. Methods: A prospective study of the ultrasound features of 35 sites of tophi nodulations in the elbows of 31 men (mean 54.6 years). The findings were evaluated dynamically following pre-established standards. The static images were evaluated by another radiologist and were reviewed by the first examiner. Results: The most frequent characteristics of tophi are: hyperechogenicity (91.7%), poorly defined contours (88.6%), multiple grouped nodules (85.6%) and heterogeneity (68.6%). Intra-observer agreement is almost perfect for echogenicity (K = 1.0), moderate for the involvement of the olecranon bursa (K = 0.47) and fair for other characteristics. Inter-observer agreement is substantial for the echogenicity (K = 0.65), fair for the echotexture (K = 0.27) and the presence of a perilesional hypoechoic halo (K = 0.34) and slight for other characteristics. Conclusions: The most frequent characteristic of tophi is hyperechogenicity. The intra-observer and inter-observer concordance for echogenicity are almost perfect and substantial, respectively. Knowledge of characteristics of the tophi in the elbow and their intra and inter-observer reproducibility may assist in establishing parameters for monitoring treatment and setting up criteria for differential diagnosis of processes involving the olecraneon bursa.

  14. Compartment elasticity measured by pressure-related ultrasound to determine patients "at risk" for compartment syndrome: an experimental in vitro study.

    Science.gov (United States)

    Sellei, Richard Martin; Hingmann, Simon Johannes; Kobbe, Philipp; Weber, Christian; Grice, John Edward; Zimmerman, Frauke; Jeromin, Sabine; Hildebrand, Frank; Pape, Hans-Christoph

    2015-01-01

    Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. In an in vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intra-compartmental pressures (p) were raised subsequently up to 80 mmHg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mmHg) upon the surface resulting in a linear compartmental displacement (∆d). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mmHg) occurred. The Pearson coefficient showed a high correlation (r(2) = -0.960). The intra-observer reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete compartmental elasticity by ultrasound

  15. MO-DE-210-03: Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities

    International Nuclear Information System (INIS)

    Ding, K.

    2015-01-01

    Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities. It is inexpensive, portable and provides good soft tissue contrast. For challenging soft tissue targets such as pancreatic cancer, ultrasound imaging can be used in combination with pre-treatment MRI and/or CT to transfer important anatomical features for target localization at time of treatment. The non-invasive and non-ionizing nature of ultrasound imaging is particularly powerful for intra-fraction localization and monitoring. Recognizing these advantages, efforts are being made to incorporate novel robotic approaches to position and manipulate the ultrasound probe during irradiation. These recent enabling developments hold potential to bring ultrasound imaging to a new level of IGRT applications. However, many challenges, not limited to image registration, robotic deployment, probe interference and image acquisition rate, need to be addressed to realize the full potential of IGRT with ultrasound imaging. Learning Objectives: Understand the benefits and limitations in using ultrasound to augment MRI and/or CT for motion monitoring during radiation therapy delivery. Understanding passive and active robotic approaches to implement ultrasound imaging for intra-fraction monitoring. Understand issues of probe interference with radiotherapy treatment. Understand the critical clinical workflow for effective and reproducible IGRT using ultrasound guidance. The work of X.L. is supported in part by Elekta; J.W. and K.D. is supported in part by a NIH grant R01 CA161613 and by Elekta; D.H. is support in part by a NIH grant R41 CA174089

  16. MO-DE-210-03: Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K. [Johns Hopkins University: Development of Intra-Fraction Soft Tissue Monitoring with Ultrasound Imaging (United States)

    2015-06-15

    Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities. It is inexpensive, portable and provides good soft tissue contrast. For challenging soft tissue targets such as pancreatic cancer, ultrasound imaging can be used in combination with pre-treatment MRI and/or CT to transfer important anatomical features for target localization at time of treatment. The non-invasive and non-ionizing nature of ultrasound imaging is particularly powerful for intra-fraction localization and monitoring. Recognizing these advantages, efforts are being made to incorporate novel robotic approaches to position and manipulate the ultrasound probe during irradiation. These recent enabling developments hold potential to bring ultrasound imaging to a new level of IGRT applications. However, many challenges, not limited to image registration, robotic deployment, probe interference and image acquisition rate, need to be addressed to realize the full potential of IGRT with ultrasound imaging. Learning Objectives: Understand the benefits and limitations in using ultrasound to augment MRI and/or CT for motion monitoring during radiation therapy delivery. Understanding passive and active robotic approaches to implement ultrasound imaging for intra-fraction monitoring. Understand issues of probe interference with radiotherapy treatment. Understand the critical clinical workflow for effective and reproducible IGRT using ultrasound guidance. The work of X.L. is supported in part by Elekta; J.W. and K.D. is supported in part by a NIH grant R01 CA161613 and by Elekta; D.H. is support in part by a NIH grant R41 CA174089.

  17. Trial Comparing a Combined Regimen of Amikacin and Ciprofloxacin to Ciprofloxacin Alone as Transrectal Prostate Biopsy Prophylaxis in the Era of High Fluoroquinolone-Resistant Rectal Flora.

    Science.gov (United States)

    Son, Kyung Chul; Chung, Ho Seok; Jung, Seung Il; Kim, Myung Soo; Hwang, Eu Chang; Kim, Jin Woong; Kwon, Dong Deuk

    2018-04-09

    To investigate whether addition of amikacin to fluoroquinolone (FQ) antimicrobial prophylaxis reduces infections after transrectal ultrasound-guided prostate biopsy (TRUSPB). A total of 503 patients undergoing rectal swab were divided into three groups. Patients with FQ-sensitive rectal flora (group 1, n = 248) were administered ciprofloxacin before TRUSPB, and patients with FQ-resistant rectal flora were either administered ciprofloxacin (group 2, n = 97) or amikacin and ciprofloxacin (group 3, n = 158) before TRUSPB. Based on the rectal swab, FQ resistance was 54.9%, and extended-spectrum β-lactamase (ESBL) positivity was 17.2%. The incidence of infectious complication in group 1 was 1.6%. Groups 2 and 3, with FQ-resistant rectal flora, tended to have increased infectious complications (5.2% and 4.4%, respectively) but the difference between those results is not statistically significant. The most common pathogens of infectious complications in patients with FQ-resistant rectal flora were FQ-resistant and ESBL-producing Escherichia coli. E. coli pathogens isolated in Group 3 were amikacin-susceptible species. The operation history and ESBL positivity of rectal flora increased the incidence of infectious complications (odds ratio [OR] = 3.68; P = 0.035 and OR = 4.02; P = 0.008, respectively). DM and antibiotics exposure were risk factors for FQ resistance (OR = 2.19; P = 0.002) and ESBL positivity of rectal flora (OR = 2.96; P = 0.005), respectively. Addition of amikacin to ciprofloxacin prophylaxis could not reduce infectious complications in patients with FQ-resistant rectal flora. Despite the amikacin sensitivity of infectious complications, single-dose amikacin addition to ciprofloxacin prophylaxis has limitations. © 2018 The Korean Academy of Medical Sciences.

  18. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  19. Dual phase helical CT versus portal venous phase CT for the detection of colorectal liver metastases: Correlation with intra-operative sonography, surgical and pathological findings

    International Nuclear Information System (INIS)

    Scott, D. John; Guthrie, J. Ashley; Arnold, Paul; Ward, Janice; Atchley, Julian; Wilson, Daniel; Robinson, Philip J.

    2001-01-01

    AIM: To assess whether dual phase helical computed tomography (DPCT) of the liver improves the detection of colorectal liver metastases compared with portal venous phase (PVP) imaging alone. MATERIALS AND METHODS: DPCT was performed in 33 consecutive patients before laparotomy for resection of colorectal liver metastases. CT comprised 8-mm slice collimation with a pitch of 1 to 1.25; imaging was commenced 20-25 and 65-70 s after the start of injection of 150 ml of contrast medium at 5 ml/s to coincide with hepatic arterial phase (HAP) and PVP contrast enhancement, respectively. Four blinded observers independently reviewed the HAP, PVP and DPCT images recording the site and size of all lesions. Alternative-free response receiver operating characteristic (AFROC) methodology was used to analyse the results, which were correlated with surgery, intra-operative ultrasound and histology. RESULTS: The mean observer sensitivities for malignant lesion detection were 75.3% for DPCT, 69.7% for PVP imaging and 66.7% for HAP imaging alone. There was a statistically significant improvement in malignant lesion detection using DPCT when compared with PVP imaging alone (P < 0.05). The mean areas under the AFROC curves were 0.84 for DPCT and 0.82 for PVP (P < 0.03) imaging alone. CONCLUSION: The detection of colorectal liver metastases was marginally better with DPCT than with PVP imaging alone, but the discovery of additional lesions did not affect the management of any of the patients in this study. Scott, D.J. et al. (2001)

  20. INTRA graphical package - INTRA-Graph 1.0

    International Nuclear Information System (INIS)

    Hofman, D.; Edlund, O.

    2001-04-01

    INTRA-Graph 1.0 has been developed at Studsvik Eco and Safety AB in the frame of the European Fusion Technology Programme for application in the safety analysis using the INTRA code. INTRA-Graph 1.0 is a graphical package producing 2-dimensional plots of results generated by the INTRA code. INTRA-Graph 1.0 has been developed by extending the Grace package source code, distributed under the terms of GNU General Public License. The changes in the Grace source files are limited to provide easy updates of the INTRA-Graph when a new version of Grace will be released. The INTRA-related functionality has been implemented in new source files. The present report describes and gives complete listing of these files. The changes in the Grace source files are also described and the listing of the changed parts of the files is presented. The report gives detailed explanations and examples of files required for installation and configuration of INTRA-Graph on the different types of Unix workstations

  1. Measurement of compartment elasticity using pressure related ultrasound: a method to identify patients with potential compartment syndrome.

    Science.gov (United States)

    Sellei, R M; Hingmann, S J; Kobbe, P; Weber, C; Grice, J E; Zimmerman, F; Jeromin, S; Gansslen, A; Hildebrand, F; Pape, H C

    2015-01-01

    PURPOSE OF THE STUDY Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. MATERIAL AND METHODS In an in-vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intracompartmental pressures (p) were raised subsequently up to 80 mm Hg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mm Hg) upon the surface resulting in a linear compartmental displacement (Δd). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. RESULTS With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mm Hg) occurred. The Pearson's coefficient showed a high correlation (r2 = -0.960). The intraobserver reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). CONCLUSIONS Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete

  2. Feasibility of a 2"n"d generation MR-compatible manipulator for transrectal prostate biopsy guidance

    International Nuclear Information System (INIS)

    Bomers, J.G.R.; Yakar, D.; Bosboom, D.G.H.; Tigelaar, G.H.; Sabisch, J.; Fuetterer, J.J.

    2017-01-01

    To assess the feasibility of a 2"n"d generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  3. Reliability tests and guidelines for B-mode ultrasound assessment of central adiposity.

    Science.gov (United States)

    Stoner, Lee; Chinn, Victoria; Cornwall, Jon; Meikle, Grant; Page, Rachel; Lambrick, Danielle; Faulkner, James

    2015-11-01

    Ultrasound represents a validated and relatively inexpensive diagnostic device for assessing central adiposity; however, widespread adoption has been impeded by the lack of reliable standard operating procedures. To examine the reliability of, and describe guidelines for, ultrasound-derived recording of intra-abdominal fat thickness (IAT) and maximal preperitoneal fat thickness (PFT). Ultrasound scans were obtained from 20 adults (50% female, 26 ± 7 years, 24·5 kg/m(2) ) on three different mornings. IAT was assessed 2 cm above the umbilicus (transverse plane) measuring from linea alba to: (i) anterior aorta, (ii) posterior aorta and (iii) anterior aspect of the vertebral column. PFT was measured from linea alba to visceral peritoneum in (i) sagittal and (ii) transverse planes, immediately over and inferior to the xiphi-sternum, respectively. For IAT, the criterion intraclass correlation coefficient (ICC) of 0·75 was exceeded for measurements to anterior aorta (0·95), posterior aorta (0·94) and vertebra (0·96). The reliability coefficient expressed as a percentage of the mean (RC%) was lowest (better) for measurement to vertebrae (9·8%). For PFT, mean thickness was comparable for sagittal (1·74 cm) and transverse (1·76 cm) planes; ICC values were also comparable for both planes (0·98 vs. 0·98, respectively), as were RC% (7·5% vs. 7·1%, respectively). IAT assessments to the vertebra were marginally more reliable than those to other structures. While PFT assessments were equally reliable for both measurements planes, precise probe placement was easier for the sagittal plane. Based on these findings, guidelines for the reliable measurement of central adiposity using ultrasound are presented. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  4. Applicability of contrast-enhanced ultrasound in the diagnosis of plantar fasciitis.

    Science.gov (United States)

    Broholm, R; Pingel, J; Simonsen, L; Bülow, J; Johannsen, F

    2017-12-01

    Contrast-enhanced ultrasound (CEUS) is used to visualize the microvascularization in various tissues. The purpose of this study was to investigate whether CEUS could be used to visualize the microvascular volume (MV) in the plantar fascia, and to compare the method to clinical symptoms and B-mode ultrasound (US) in patients with plantar fasciitis (PF). Twenty patients with unilateral PF were included and were divided by US in insertional thickening (10), midsubstance thickening (5), and no US changes (5). The MV was measured simultaneously in both heels. Four areas in the plantar fascia and plantar fat pad were measured independently by two observers. Inter- and intra-observer correlation analyses were performed. The asymptomatic heels showed a constantly low MV, and for the whole group of patients, a significantly higher MV was found in the symptomatic plantar fascia and plantar fat pad. Inter-observer correlation as well as intra-observer agreement was excellent. The MV in the plantar fascia and plantar fat pad can be measured reliably using CEUS, suggesting that it is a reproducible method to examine patients with plantar fasciitis. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Factors impacting short and long-term kidney graft survival: modification by single intra-operative -high-dose induction with ATG-Fresenius.

    Science.gov (United States)

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2011-01-01

    A majority of recipients benefited from the intra-operative single high-dose induction (HDI) with ATG-Fresenius (ATG-F) still leaving a group of recipients who did not profit from this kind of induction. Therefore the aim of this retrospective analysis was 1st to identify the risk factors impacting short and long-term graft survival, and 2nd to assess the efficacy of this type of induction in kidney graft recipients with or without these risk factors. A total of 606 recipients receiving two different immunosuppressive treatment regimens (1st: Triple drug therapy [TDT, n=196] consisting mainly of steroids, azathioprine and cyclosporine; 2nd: TDT + 9 mg/kg ATG-F intra-operatively [HDI, n=410]) were included in this analysis and grouped according to their kidney graft survival time (short GST: ≤1 yr, n=100 and long GST: >5 yrs, n=506). The main risk factors associated with a shortened graft survival were pre-transplant sensitization, re-transplantation, rejections (in particular vascular or mixed ones) and the necessity of a long-term anti-rejection therapy. Adding ATG-F single high dose induction to TDT was more efficient in prolonging kidney graft survival than TDT alone not only in recipients without any risk factors (p<0.005) but also in recipients with at least one risk factor (p<0.021). Only in 4.6% of recipients having two or more risk factors this effect could not be demonstrated. The intra-operative single high-dose induction with ATG-F significantly improves the kidney graft survival in recipients with or without risk factors and can therefore be recommended.

  6. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    Science.gov (United States)

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio benign and malignant nodules in 2, 3 and 4 points were statistically significant (Pbenign and malignant thyroid nodules.

  7. Comparison of CT scan and colour flow doppler ultrasound in detecting venous tumour thrombous in renal cell carcinoma

    International Nuclear Information System (INIS)

    Khan, A.R.; Anwar, K.

    2008-01-01

    Renal cell carcinoma has marked tendency to spread into renal vein, inferior vena cava and right side of heart. Extension of tumour thrombus into these veins will alter the surgical approach. We have compared the CT scan with Colour flow Doppler ultrasound in detecting venous tumour thrombus in renal vein and inferior vena cava. This cross-sectional study included 30 adult patients presenting with renal tumour. Patients of either gender were included in the study. Non probability convenience sampling was used. All patients underwent colour flow Doppler ultrasound and CT scan with contrast to asses the renal vein and inferior vena cava. The results were confirmed by intra operative findings and histopathology. The data was analyzed using SPSS version 12. Out of 30 patients, 20 (66%) were males and 10 (34%) female. The tumour was predominantly on the right side (60%), as was renal venous tumour thrombus (44%). Inferior vena cava was involved in 4 cases predominantly due to right sided tumours. The sensitivity of Doppler ultrasound in detecting renal venous tumour thrombus (88% on right and 100% on left side) was higher than CT scan (63% on right and 60% on left side). Doppler ultrasound was also superior to CT scan in detecting vena caval thrombus. The overall sensitivity of Doppler sonography was higher than CT scan in detecting tumour extension into renal veins and inferior vena cava. Therefore, it can be used as a complementary tool in equivocal cases. (author)

  8. The thickness of the A1 pulleys reflects the disability of hand mobility in scleroderma. A pilot study using high-frequency ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto, E-mail: atagliafico@sirm.org [Department of Radiology, National Institute for Cancer Research, Genova (Italy); Panico, Nicoletta [Division of Immunology, Department of Internal Medicine, University of Genova, Genova (Italy); Serafini, Giovanni [Department of Radiology, Santa Corona Hospital, Pietra Ligure (Italy); Ghio, Massimo [Division of Immunology, Department of Internal Medicine, University of Genova, Genova (Italy); Martinoli, Carlo [Department of Radiology, University of Genova, Genova (Italy)

    2011-02-15

    Background: Hand involvement in scleroderma is a serious concern. Clinical tests to asses hand dysfunction are based on the experience of the clinician. Objective: To asses if utrasonographic (US) measurement of A1 pulley thickness may be used as an indicator of hand mobility in scleroderma. Materials and methods: Institutional review board approval and patient informed consent was obtained. Twenty-eight patients affected suffering from scleroderma and 40 healthy controls were prospectively evaluated by two blinded radiologists with US, with a transducer operating at 17 MHz. A1 pulley thickness was measured and correlated with the Hand Mobility in Scleroderma Test (HAMIS) and disease duration. Results: The thickness of the A1 pulley was greater in sclerodermic patients than in controls (p < 0.05). Intra and inter-observer agreement were better for ultrasound (0.94;0.88) than for HAMIS tests (0.71;0.70). A good correlation between pulley thickness, hand mobility and disease duration was found (r = 0.78, p < 0.018; r = 0.54, p < 0.05). Conclusion: A1 pulley thickness measured on ultrasound correlates with hand mobility and disease duration. Ultrasound is an useful tool to evaluate hand disability in scleroderma.

  9. The thickness of the A1 pulleys reflects the disability of hand mobility in scleroderma. A pilot study using high-frequency ultrasound

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Panico, Nicoletta; Serafini, Giovanni; Ghio, Massimo; Martinoli, Carlo

    2011-01-01

    Background: Hand involvement in scleroderma is a serious concern. Clinical tests to asses hand dysfunction are based on the experience of the clinician. Objective: To asses if utrasonographic (US) measurement of A1 pulley thickness may be used as an indicator of hand mobility in scleroderma. Materials and methods: Institutional review board approval and patient informed consent was obtained. Twenty-eight patients affected suffering from scleroderma and 40 healthy controls were prospectively evaluated by two blinded radiologists with US, with a transducer operating at 17 MHz. A1 pulley thickness was measured and correlated with the Hand Mobility in Scleroderma Test (HAMIS) and disease duration. Results: The thickness of the A1 pulley was greater in sclerodermic patients than in controls (p < 0.05). Intra and inter-observer agreement were better for ultrasound (0.94;0.88) than for HAMIS tests (0.71;0.70). A good correlation between pulley thickness, hand mobility and disease duration was found (r = 0.78, p < 0.018; r = 0.54, p < 0.05). Conclusion: A1 pulley thickness measured on ultrasound correlates with hand mobility and disease duration. Ultrasound is an useful tool to evaluate hand disability in scleroderma.

  10. Seminal, clinical and colour-Doppler ultrasound correlations of prostatitis-like symptoms in males of infertile couples.

    Science.gov (United States)

    Lotti, F; Corona, G; Mondaini, N; Maseroli, E; Rossi, M; Filimberti, E; Noci, I; Forti, G; Maggi, M

    2014-01-01

    'Prostatitis-like symptoms' (PLS) are a cluster of bothersome conditions defined as 'perineal and/or ejaculatory pain or discomfort and National Institutes of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) pain subdomain score ≥4' (Nickel's criteria). PLS may originate from the prostate or from other portions of the male genital tract. Although PLS could be associated with 'prostatitis', they should not be confused. The NIH-CPSI is considered the gold-standard for assessing PLS severity. Although previous studies investigated the impact of prostatitis, vesiculitis or epididymitis on semen parameters, correlations between their related symptoms and seminal or scrotal/transrectal colour-Doppler ultrasound (CDU) characteristics have not been carefully determined. And no previous study evaluated the CDU features of PLS in infertile men. This study was aimed at investigating possible associations among NIH-CPSI (total and subdomain) scores and PLS, with seminal, clinical and scrotal/transrectal CDU parameters in a cohort of males of infertile couples. PLS of 400 men (35.8 ± 7.2 years) with a suspected male factor were assessed by the NIH-CPSI. All patients underwent, during the same day, semen analysis, seminal plasma interleukin 8 (sIL-8, a marker of male genital tract inflammation), biochemical evaluation, urine/seminal cultures, scrotal/transrectal CDU. PLS was detected in 39 (9.8%) subjects. After adjusting for age, waist and total testosterone (TT), no association among NIH-CPSI (total or subdomain) scores or PLS and sperm parameters was observed. However, we found a positive association with current positive urine and/or seminal cultures, sIL-8 levels and CDU features suggestive of inflammation of the epididymis, seminal vesicles, prostate, but not of the testis. The aforementioned significant associations of PLS were further confirmed by comparing PLS patients with age-, waist- and TT-matched PLS-free patients (1 : 3 ratio). In conclusion, NIH

  11. Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

    Science.gov (United States)

    Ventura-Ríos, Lucio; Hernández-Díaz, Cristina; Ferrusquia-Toríz, Diana; Cruz-Arenas, Esteban; Rodríguez-Henríquez, Pedro; Alvarez Del Castillo, Ana Laura; Campaña-Parra, Alfredo; Canul, Efrén; Guerrero Yeo, Gerardo; Mendoza-Ruiz, Juan Jorge; Pérez Cristóbal, Mario; Sicsik, Sandra; Silva Luna, Karina

    2017-12-01

    This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS-Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen's kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.

  12. Intraoperative ultrasonography in nine dogs with intra-abdominal neoplasm suspect

    Directory of Open Access Journals (Sweden)

    Daniella Matos da Silva

    Full Text Available ABSTRACT: Intraoperative ultrasonography (IOUS is used in medicine for diagnosis and guidance during oncologic surgery. The aims of this study were to assess the performance, feasibility, advantages and difficulties of the IOUS technique in dogs with suspected intra-abdominal tumors. The study included nine client-owed dogs that had suspected intra-abdominal tumors (spleen, liver or bowel based on transabdominal ultrasound examination and that were subsequently referred for exploratory laparotomy surgery. During surgery, IOUS was performed; results of preoperative transabdominal ultrasonography, inspection by the surgeon and IOUS were compared on a case-by-case basis. IOUS was helpful in determining lesion resection in all cases. Lesions detected solely by the use of IOUS were observed in seven out of nine cases. Analysis of these cases demonstrated that IOUS can be a tool to assist during oncology surgery on the liver, spleen or bowel. Dogs with hepatic tumors can have small non-palpable intraparenchymal nodules, which may be visible by IOUS.

  13. Ultrasound characterization of the seminal vesicles in infertile patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    La Vignera, Sandro; Vicari, Enzo; Condorelli, Rosita; D'Agata, Rosario; Calogero, Aldo E.

    2011-01-01

    Male patients with type 2 diabetes mellitus (DM) may experience infertility because the disease affects negatively many aspects of reproduction, including seminal vesicle (SV) function. The aim of this study was to evaluate the ultrasound characteristics of the SVs of infertile patients with DM because no such data are available in these patients. To accomplish this, 25 infertile patients with type 2 DM and no other known causes of sperm parameter abnormalities were selected. Two different control groups were also enrolled: healthy men with idiopathic infertility (n = 25) and infertile patients with male accessory gland infections (MAGI) (n = 25), a well-studied clinical model of SV inflammation. Patients and controls underwent prostate-vesicular transrectal ultrasonography after 1 day of sexual abstinence before and 1 h after ejaculation. The following SV ultrasound parameters were recorded: (1) body antero-posterior diameter (ADP); (2) fundus APD; (3) parietal thickness of the right and left SVs; (4) number of polycyclic areas within both SVs; (5) fundus/body ratio; (6) difference of the parietal thickness between the right and the left SV; and (7) pre- and post-ejaculatory APD difference. Patients with DM had a significantly (p < 0.05) higher F/B ratio compared to controls and patients with MAGI. Only patients with MAGI had a significantly (p < 0.05) higher number of polycyclic areas. Controls and MAGI patients have a similar pre- and post-ejaculatory difference of the body SV APD, whereas this difference was significantly (p < 0.05) lower in patients with DM. In conclusion, this study showed that infertile patients with DM have peculiar SV ultrasound features suggestive of functional atony.

  14. Ultrasound characterization of the seminal vesicles in infertile patients with type 2 diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    La Vignera, Sandro; Vicari, Enzo; Condorelli, Rosita; D' Agata, Rosario [Section of Endocrinology, Andrology and Internal Medicine and Master in Andrological, Human Reproduction and Biotechnology Sciences, Department of Biomedical Sciences, University of Catania, Catania (Italy); Calogero, Aldo E., E-mail: acaloger@unict.it [Section of Endocrinology, Andrology and Internal Medicine and Master in Andrological, Human Reproduction and Biotechnology Sciences, Department of Biomedical Sciences, University of Catania, Catania (Italy)

    2011-11-15

    Male patients with type 2 diabetes mellitus (DM) may experience infertility because the disease affects negatively many aspects of reproduction, including seminal vesicle (SV) function. The aim of this study was to evaluate the ultrasound characteristics of the SVs of infertile patients with DM because no such data are available in these patients. To accomplish this, 25 infertile patients with type 2 DM and no other known causes of sperm parameter abnormalities were selected. Two different control groups were also enrolled: healthy men with idiopathic infertility (n = 25) and infertile patients with male accessory gland infections (MAGI) (n = 25), a well-studied clinical model of SV inflammation. Patients and controls underwent prostate-vesicular transrectal ultrasonography after 1 day of sexual abstinence before and 1 h after ejaculation. The following SV ultrasound parameters were recorded: (1) body antero-posterior diameter (ADP); (2) fundus APD; (3) parietal thickness of the right and left SVs; (4) number of polycyclic areas within both SVs; (5) fundus/body ratio; (6) difference of the parietal thickness between the right and the left SV; and (7) pre- and post-ejaculatory APD difference. Patients with DM had a significantly (p < 0.05) higher F/B ratio compared to controls and patients with MAGI. Only patients with MAGI had a significantly (p < 0.05) higher number of polycyclic areas. Controls and MAGI patients have a similar pre- and post-ejaculatory difference of the body SV APD, whereas this difference was significantly (p < 0.05) lower in patients with DM. In conclusion, this study showed that infertile patients with DM have peculiar SV ultrasound features suggestive of functional atony.

  15. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Rectal culture-directed antibiotic prophylaxis before transrectal prostate biopsy: Reduced infectious complications and healthcare costs.

    Science.gov (United States)

    Baldissera-Aradas, J V; Rodríguez-Villamil, L; Blanco-Fernández, R; Pérez-García, C; Viejo de la Guerra, G; González-Rodríguez, I; Mosquera-Madera, J

    2018-01-10

    Transrectal ultrasound-guided prostate biopsy (TUPB) is associated with infectious complications (ICs), which are related to a greater prevalence of ciprofloxacin-resistant bacteria (CRB) in rectal flora. We examined the ICs that occurred in 2 groups: A guided antibiotic prophylaxis (GP) group and an empiric prophylaxis (EP) group. We assessed the financial impact of GP. The GP group was studied prospectively (June 2013 to July 2014). We collected rectal cultures (RCs) before the TUPB, which were seeded on selective media with ciprofloxacin to determine the presence of CRB. The patients with sensitive bacteria were administered ciprofloxacin. Patients with resistant bacteria were administered GP according to the RC antibiogram. The EP group was studied retrospectively (January 2011 to June 2009). RCs were not performed, and all patients were treated with ciprofloxacin as prophylaxis. The ICs in both groups were recorded during a period no longer than 30 days following TUPB (electronic medical history). Three hundred patients underwent TUPB, 145 underwent GP, and 155 underwent EP. In the GP group, 23 patients (15.86%) presented CRB in the RCs. Only one patient (0.7%) experienced a UTI. In the EP group, 26 patients (16.8%) experienced multiple ICs (including 2 cases of sepsis) (P<.005). The estimated total cost, including the management of the ICs, was €57,076 with EP versus €4802.33 with GP. The average cost per patient with EP was €368.23 versus €33.11 with GP. GP achieved an estimated total savings of €52,273.67. Six patients had to undergo GP to prevent an IC. GP is associated with a marked decrease in the incidence of ICs caused by CRB and reduced healthcare costs. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    Science.gov (United States)

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  18. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael, E-mail: michael.meier@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Homsi, Rami, E-mail: rami.homsi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Kukuk, Guido, E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Wolter, Karsten, E-mail: karsten.wolter@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Decker, Georges, E-mail: georges.decker@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Fischer, Stefan, E-mail: stefan.fischer@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Marx, Christian, E-mail: christian.marx@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schmeel, Frederic Carsten, E-mail: carsten.schmeel@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Block, Wolfgang, E-mail: wolfgang.block@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Sprinkart, Alois Martin, E-mail: sprinkart@uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Hospital of the Barmherzige Brüder Trier, Nordallee 1, 54292 Trier (Germany)

    2016-12-15

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  19. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Homsi, Rami; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Schmeel, Frederic Carsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Willinek, Winfried

    2016-01-01

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  20. Principles of Billing for Diagnostic Ultrasound in the Office and Operating Room.

    Science.gov (United States)

    Grasu, Beatrice L; Wolock, Bruce S; Sedgley, Matthew D; Murphy, Michael S

    2018-05-08

    Ultrasound is becoming more prevalent as physicians gain comfort in its diagnostic and therapeutic uses. It allows for both static and dynamic evaluation of conditions and assists in therapeutic injections of joints and tendons. Proper technique is necessary for successful use of this modality. Appropriate coding for physician reimbursement is required. We discuss common wrist and hand pathology for which ultrasound may be useful as an adjunct to diagnosis and treatment and provide an overview of technique and reimbursement codes when using ultrasound in a variety of situations. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Feasibility of a 2{sup nd} generation MR-compatible manipulator for transrectal prostate biopsy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Bomers, J.G.R.; Yakar, D. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Bosboom, D.G.H. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Soteria Medical, Arnhem (Netherlands); Tigelaar, G.H.; Sabisch, J. [Soteria Medical, Arnhem (Netherlands); Fuetterer, J.J. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-04-15

    To assess the feasibility of a 2{sup nd} generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  2. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    Science.gov (United States)

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers

  3. Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging

    International Nuclear Information System (INIS)

    McCarthy, C.L.; Wilson, D.J.; Coltman, T.P.

    2008-01-01

    The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in

  4. Intra-operative rapid diagnostic method based on CK19 mRNA expression for the detection of lymph node metastases in breast cancer

    NARCIS (Netherlands)

    Visser, Mike; Jiwa, Mehdi; Horstman, Anja; Brink, Antoinette A. T. P.; Pol, Rene P.; van Diest, Paul; Snijders, Peter J. F.; Meijer, Chris J. L. M.

    2008-01-01

    Staging by sentinel node (SN) biopsy is the standard procedure for clinically node-negative breast cancer patients. Intra-operative analysis of the SN allows immediate axillary lymph node (ALN) dissection in SN positive patients, but a quick, reliable and reproducible method is lacking. We tested

  5. Systematic Review and Meta-Analysis of Randomized Controlled Trials Evaluating Prophylactic Intra-Operative Wound Irrigation for the Prevention of Surgical Site Infections

    NARCIS (Netherlands)

    de Jonge, Stijn W.; Boldingh, Quirine J. J.; Solomkin, Joseph S.; Allegranzi, Benedetta; Egger, Matthias; Dellinger, E. Patchen; Boermeester, Marja A.

    2017-01-01

    Surgical site infections (SSIs) are one of the most common hospital-acquired infections. To reduce SSIs, prophylactic intra-operative wound irrigation (pIOWI) has been advocated, although the results to date are equivocal. To develop recommendations for the new World Health Organization (WHO) SSI

  6. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning

    International Nuclear Information System (INIS)

    Whelehan, P.; Vinnicombe, S.J.; Brown, D.C.; McLean, D.; Evans, A.

    2014-01-01

    Aim: To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Materials and methods: Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1–2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. Results: A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63–86%). Conclusion: This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. - Highlights: • Percutaneous radio-isotope guided localisation of the SLN was successful in 75% of cases. • Success rates varied slightly by operator. • Success rates did not vary between same-day and previous-day isotope injection methods

  7. Frozen section is superior to imprint cytology for the intra-operative assessment of sentinel lymph node metastasis in Stage I Breast cancer patients

    Directory of Open Access Journals (Sweden)

    Makita Masujiro

    2006-05-01

    Full Text Available Abstract Background A standard intra-operative procedure for assessing sentinel lymph node metastasis in breast cancer patients has not yet been established. Patients and methods One hundred and thirty-eight patients with stage I breast cancer who underwent sentinel node biopsy using both imprint cytology and frozen section were analyzed. Results Seventeen of the 138 patients had sentinel node involvement. Results of imprint cytology included nine false negative cases (sensitivity, 47.1%. In contrast, only two cases of false negatives were found on frozen section (sensitivity, 88.2%. There were two false positive cases identified by imprint cytology (specificity, 98.3%. On the other hand, frozen section had 100% specificity. Conclusion These findings suggest that frozen section is superior to imprint cytology for the intra-operative determination of sentinel lymph node metastasis in stage I breast cancer patients.

  8. Ultrasound Instrumentation for Beam Diagnostics and Accelerating Structures Control

    CERN Document Server

    Moiseev, V I

    2005-01-01

    Sensitive elements and electronics for ultrasound measurements at conducting walls of beam pipes and accelerating structures are described. Noise protected instrumentation provides ultrasound spectra analysis in a wide frequency range up to 5 MHz.In circular accelerators, ultrasound fields in conducting walls of beam pipe represent the space-time characteristics of circulating beams. In accelerating structures, real high power operation modes of structure can be studied by outer ultrasound monitors. The experimental results at KSRS accelerators are discussed.

  9. Sonomammography: An atlas of comparative breast ultrasound

    International Nuclear Information System (INIS)

    Guyer, B.P.; Dewsbury, K.C.

    1987-01-01

    This atlas of breast ultrasound is extensively illustrated and provides a short analytical text before each group of pathologies. Although based on B-scan techniques, there are numerous comparisons with sector scans and linear array scans. X-ray mammography and breast ultrasound is analyzed, based upon 2000 sonomammograms, showing how a more accurate pre-operation assessment can be made, and how unnecessary surgery can be reduced. Major features of this atlas include a detailed analysis of the appearances of breast lesions, extensive illustrations of the various pathologies (generally confirmed histologically), a close comparison of ultrasound with x-ray mammography, and illustrations of lesions by different ultrasound techniques

  10. VALIDATION OF MITRAL VALVE ANNULUS DIMENSIONS MEASURED BY 2D TRANS-THORACIC ECHOCARDIOGRAPHY WITH GOLD STANDARD DIRECT INTRA-OPERATIVE MEASUREMENT

    OpenAIRE

    Praveen; Yadav; Ankur; Saket; Kaushal

    2014-01-01

    CONTEXT: Precise estimation of Mitral valve annulus dimensions preoperatively through Echocardiography is of paramount importance in replacement/repair surgeries. However a frequent disagreement was experienced between anticipated size of prosthetic valve based on echocardiography and actual valve size. This fact encouraged the authors to validate the measurements through echocardiography with gold-standard direct intra operative measurement. AIM: To compare the mitral val...

  11. Usefulness of transrectal ultrasound in diagnosing prostate cancer: comparison with digital rectal examination, prostate-specific antigen and prostate-specific antigen density

    International Nuclear Information System (INIS)

    Yoon, Jung Hwan; Kim, Bo Hyun; Choi, Sang Hee; Kim, Seung Hoon; Choi, Han Yong; Chai, Soo Eung; Yoon, Hye Kyung; Lee, Soon Jin; Choo, In Wook; Kim, Bo Kyung

    1998-01-01

    To determine the usefulness of transrectal ultrasonography (TRUS) in diagnosing prostate cancer by comparing the sensitivity, specificity, accuracy, and positive and negative predictive values of TRUS with those of serum prostate-specific antigen (PSA), prostate-specific antigen density (PSAD) and digital rectal examination (DRE). Two hundred and ten consecutive patients underwent TRUS-guided prostate biopsy due to elevated PSA and/or abnormal findings on TRUS or DRE. The TRUS findings were analyzed and correlated with pathological diagnosis. PSAD was calculated by dividing the serum PSA level by the prostate volume calculated on TRUS. The sensitivity, specificity, accuracy, and positive and negative predictive values of TRUS were compared with those of PSA, PSAD and DRE. Using ROC curve analysis, the combinations of these diagnostic methods were also evaluated for the determination of efficacy in diagnosing prostate cancer. The sensitivity and specificity of serum PSA (cut-off level, 4ng/ml), PSAD (cut-off level, 0.15ng/ml/cm 3 ), DRE, and TRUS were 96%/17%, 96%/37%, 72%/62%, and 89%/68%, respectively. On TRUS, the sensitivity and specificity of low echoic lesions and those of irregular outer margin were 89%/69%, and 60%/90%, respectively. TRUS was statistically more accurate than other diagnostic methods. Of the combinations of diagnostic methods, TRUS and PSAD were most accurate. TRUS demonstrated lower sensitivity but higher specificity than PSA or PSAD. Although it is an accurate modality for the diagnosis of prostate cancer, it cannot be used as a confirmative test due to its relatively low positive predictive value. A combination of diagnostic methods and random biopsy is needed in patients in whom prostate cancer is suspected.=20

  12. The end of the road for prostate specific antigen testing?

    African Journals Online (AJOL)

    2012-10-01

    Oct 1, 2012 ... Abstract. Many candidate biomarkers for diagnosis of prostate cancer have been investigated, but ... prostate biopsy, the transrectal ultrasound (TRUS)‑guided .... secretions of PSA from tissues such as the breast have also.

  13. Transrectal rigid-hybrid NOTES cholecystectomy can be performed without peritoneal contamination: a controlled porcine survival study.

    Science.gov (United States)

    Müller, Philip C; Senft, Jonas D; Gath, Philip; Steinemann, Daniel C; Nickel, Felix; Billeter, Adrian T; Müller-Stich, Beat P; Linke, Georg R

    2018-01-01

    The risk of infectious complications due to peritoneal contamination is a major concern and inhibits the widespread use of transrectal NOTES. A standardized rectal washout with a reversible colon occlusion device in situ has previously shown potential in reducing peritoneal contamination. The aim of this study was to compare the peritoneal contamination rate and inflammatory reaction for transrectal cholecystectomy after ideal rectal preparation (trCCE) and standard laparoscopic cholecystectomy (lapCCE) in a porcine survival experiment. Twenty pigs were randomized to trCCE (n = 10) or lapCCE (n = 10). Before trCCE, rectal washout was performed with saline solution. A colon occlusion device was then inserted and a second washout with povidone-iodine was performed. The perioperative course and the inflammatory reaction (leukocytes, C-reactive protein) were compared. At necropsy, 14 days after surgery the abdominal cavity was screened for infectious complications and peritoneal swabs were obtained for comparison of peritoneal contamination. Peritoneal contamination was lower after trCCE than after lapCCE (0/10 vs. 6/10; p = 0.003). No infectious complications were found at necropsy in either group and postoperative complications did not differ (p = 1.0). Immediately after the procedure, leukocytes were higher after lapCCE (17.0 ± 2.7 vs. 14.6 ± 2.3; p = 0.047). Leukocytes and C-reactive protein showed no difference in the further postoperative course. Intraoperative complications and total operation time (trCCE 114 ± 32 vs. 111 ± 27 min; p = 0.921) did not differ, but wound closure took longer for trCCE (31.5 ± 19 vs. 13 ± 5 min; p = 0.002). After standardized rectal washout with a colon occlusion device in situ, trCCE was associated without peritoneal contamination and without access-related infectious complications. Based on the findings of this study, a randomized controlled clinical study comparing clinical outcomes of trCCE with

  14. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    Science.gov (United States)

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p 3years to stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Prostate segmentation by feature enhancement using domain knowledge and adaptive region based operations

    International Nuclear Information System (INIS)

    Nanayakkara, Nuwan D; Samarabandu, Jagath; Fenster, Aaron

    2006-01-01

    Estimation of prostate location and volume is essential in determining a dose plan for ultrasound-guided brachytherapy, a common prostate cancer treatment. However, manual segmentation is difficult, time consuming and prone to variability. In this paper, we present a semi-automatic discrete dynamic contour (DDC) model based image segmentation algorithm, which effectively combines a multi-resolution model refinement procedure together with the domain knowledge of the image class. The segmentation begins on a low-resolution image by defining a closed DDC model by the user. This contour model is then deformed progressively towards higher resolution images. We use a combination of a domain knowledge based fuzzy inference system (FIS) and a set of adaptive region based operators to enhance the edges of interest and to govern the model refinement using a DDC model. The automatic vertex relocation process, embedded into the algorithm, relocates deviated contour points back onto the actual prostate boundary, eliminating the need of user interaction after initialization. The accuracy of the prostate boundary produced by the proposed algorithm was evaluated by comparing it with a manually outlined contour by an expert observer. We used this algorithm to segment the prostate boundary in 114 2D transrectal ultrasound (TRUS) images of six patients scheduled for brachytherapy. The mean distance between the contours produced by the proposed algorithm and the manual outlines was 2.70 ± 0.51 pixels (0.54 ± 0.10 mm). We also showed that the algorithm is insensitive to variations of the initial model and parameter values, thus increasing the accuracy and reproducibility of the resulting boundaries in the presence of noise and artefacts

  17. Acoustic bubble sorting for ultrasound contrast agent enrichment

    NARCIS (Netherlands)

    Segers, T.J.; Versluis, Michel

    2014-01-01

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse.

  18. Intracavitary ultrasound phased arrays for prostate thermal therapies: MRI compatibility and in vivo testing.

    Science.gov (United States)

    Hutchinson, E B; Hynynen, K

    1998-12-01

    A 62 element MRI-compatible linear phased array was designed and constructed to investigate the feasibility of using transrectal ultrasound for the thermal therapeutic treatment of prostate cancer and benign prostatic hyperplasia. An aperiodic design technique developed in a previous study was used in the design of this array, which resulted in reduced grating lobe levels by using an optimized random distribution of unequally sized elements. The element sizes used in this array were selected to be favorable for both grating lobe levels as determined by array aperiodicity and array efficiency as determined by width to thickness ratios. The heating capabilities and MRI compatibility of the array were tested with in vivo rabbit thigh muscle heating experiments using MRI temperature monitoring. The array produced therapeutic temperature elevations in vivo at depths of 3-6 cm and axial locations up to 3 cm off the central axis and increased the size of the heated volume with electronic scanning of a single focus. The ability of this array to be used for ultrasound surgery was demonstrated by creating necrosed tissue lesions in vivo using short high-power sonications. The ability of the array to be used for hyperthermia was demonstrated by inducing therapeutic temperature elevations for longer exposures. Based on the acoustic and heating performance of this array, it has the potential to be clinically useful for delivering thermal therapies to the prostate and other target volumes close to body cavities.

  19. Prolonged antibiotic therapy increases risk of infection after transrectal prostate biopsy: A case report after pancreasectomy and review of the literature

    Directory of Open Access Journals (Sweden)

    Guevar Maselli

    2014-12-01

    Full Text Available Infection due to prostate biopsy afflicted more than 5% of patients and is the most common reason for hospitalization. A large series from US SEER-Medicare reported that men undergoing biopsy were 2.26 times more likely to be hospitalized for infectious complications within 30 days compared with randomly selected controls. The factors predicting a higher susceptibility to infection remain largely unknown but some authors have higlighted in the etiopathogenesis the importance of the augmented prevalence of ciprofloxacin resistant variant of bacteria in the rectum flora. We present one case of sepsis after transrectal prostate biopsy in a patient with history of pancreatic surgery. Based on our experience patients candidated to prostate biopsy with transrectal technique with history of recent major surgery represent an high risk category for infective complication. Also major pancreatic surgery should be consider an high risk category for infection. A transperineal approach and preventive measures (such as rectal swab should be adopted to reduce biopsy driven infection.

  20. Controlling the acoustic streaming by pulsed ultrasounds.

    Science.gov (United States)

    Hoyos, Mauricio; Castro, Angélica

    2013-01-01

    We propose a technique based on pulsed ultrasounds for controlling, reducing to a minimum observable value the acoustic streaming in closed ultrasonic standing wave fluidic resonators. By modifying the number of pulses and the repetition time it is possible to reduce the velocity of the acoustic streaming with respect to the velocity generated by the continuous ultrasound mode of operation. The acoustic streaming is observed at the nodal plane where a suspension of 800nm latex particles was focused by primary radiation force. A mixture of 800nm and 15μm latex particles has been also used for showing that the acoustic streaming is hardly reduced while primary and secondary forces continue to operate. The parameter we call "pulse mode factor" i.e. the time of applied ultrasound divided by the duty cycle, is found to be the adequate parameter that controls the acoustic streaming. We demonstrate that pulsed ultrasound is more efficient for controlling the acoustic streaming than the variation of the amplitude of the standing waves. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. [Risks factors associated with intra-partum foetal mortality in pre-term infants].

    Science.gov (United States)

    Zeballos Sarrato, Susana; Villar Castro, Sonia; Ramos Navarro, Cristina; Zeballos Sarrato, Gonzalo; Sánchez Luna, Manuel

    2017-03-01

    Pre-term delivery is one of the leading causes of foetal and perinatal mortality. However, perinatal risk factors associated with intra-partum foetal death in preterm deliveries have not been well studied. To analyse foetal mortality and perinatal risk factors associated with intra-partum foetal mortality in pregnancies of less than 32 weeks gestational age. The study included all preterm deliveries between 22 and 31 +1 weeks gestational age (WGA), born in a tertiary-referral hospital, over a period of 7 years (2008-2014). A logistic regression model was used to identify perinatal risk factors associated with intra-partum foetal mortality (foetal malformations and chromosomal abnormalities were excluded). During the study period, the overall foetal mortality was 63.1% (106/168) (≥22 weeks of gestation) occurred in pregnancies of less than 32 WGA. A total of 882 deliveries between 22 and 31+6 weeks of gestation were included for analysis. The rate of foetal mortality was 11.3% (100/882). The rate of intra-partum foetal death was 2.6% (23/882), with 78.2% (18/23) of these cases occurring in hospitalised pregnancies. It was found that Assisted Reproductive Techniques, abnormal foetal ultrasound, no administration of antenatal steroids, lower gestational age, and small for gestational age, were independent risk factors associated with intra-partum foetal mortality. This study showed that there is a significant percentage intra-partum foetal mortality in infants between 22 and 31+6 WGA. The analysis of intrapartum mortality and risk factors associated with this mortality is of clinical and epidemiological interest to optimise perinatal care and improve survival of preterm infants. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Is articular pain in rheumatoid arthritis correlated with ultrasound power Doppler findings?

    Science.gov (United States)

    Pereira, Daniele Freitas; Gutierrez, Marwin; de Buosi, Ana Leticia Pirozzi; Ferreira, Fernando Bernardes Maia Diniz; Draghessi, Antonella; Grassi, Walter; Natour, Jamil; Furtado, Rita Nely Vilar

    2015-11-01

    The study is addressed to determine if there is a correlation between intra-articular power Doppler (PD) and pain symptoms in patients with rheumatoid arthritis (RA). A cross-sectional study of patients with established RA was rolled out. Seventy-two patients with chronic swelling at metacarpophalangeal (MCP) joints were consecutively enrolled in the study and divided into two groups (painful and painless). In the painful group, the inclusion criteria were pain in the visual analog scale (VAS), from 0 to 10 cm, of at least 4 cm and 0 in the painless group. All two to five MCP joints, bilaterally, were scanned by ultrasound (US) searching for intra-articular PD presence. Any value of p painful group had longer morning stiffness, worse 28-joint disease activity score (DAS 28), and health assessment questionnaire (HAQ) indexes. There were no association between pain and gray scale (GS) synovitis, odds ratio (OR) = 0.9 (0.6-1.2), p = 0.485; and pain and intra-articular PD, OR = 0.8 (0.6-1.2), p = 0.244. Intra-articular PD was not correlated with pain symptom in this study.

  3. Intra-bunch-train transverse dynamics in the superconducting accelerators FLASH and European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Hellert, Thorsten

    2017-11-15

    FLASH and the European XFEL are linear accelerator driven SASE-FELs, operating in a pulsed mode with long bunch-trains. Multi-bunch FEL operation requires longitudinal and transverse stability within the bunch-train. The purpose of this work is to investigate the intra-bunch-train transverse dynamics at FLASH and XFEL. Key relationships of superconducting RF cavity operation, their misalignments and the resulting impact on the intra-bunch-train trajectory variation are described. In this thesis a numerical model is developed and simulations for different accelerating sections at FLASH and XFEL are performed. With the current operational setup significant intra-bunch-train trajectory variation must be considered, hence approaches for their reduction are discussed. The theoretical studies are compared to experimental results at FLASH. The observed trajectory variation during multi-bunch user runs is analyzed and related to causal intra-bunch-train variations of the RF and the following impact on the multi-bunch SASSE performance. Furthermore, HOM-based cavity misalignment measurements are performed and the deduction of misalignments from multi-bunch data is considered.

  4. Intra-bunch-train transverse dynamics in the superconducting accelerators FLASH and European XFEL

    International Nuclear Information System (INIS)

    Hellert, Thorsten

    2017-11-01

    FLASH and the European XFEL are linear accelerator driven SASE-FELs, operating in a pulsed mode with long bunch-trains. Multi-bunch FEL operation requires longitudinal and transverse stability within the bunch-train. The purpose of this work is to investigate the intra-bunch-train transverse dynamics at FLASH and XFEL. Key relationships of superconducting RF cavity operation, their misalignments and the resulting impact on the intra-bunch-train trajectory variation are described. In this thesis a numerical model is developed and simulations for different accelerating sections at FLASH and XFEL are performed. With the current operational setup significant intra-bunch-train trajectory variation must be considered, hence approaches for their reduction are discussed. The theoretical studies are compared to experimental results at FLASH. The observed trajectory variation during multi-bunch user runs is analyzed and related to causal intra-bunch-train variations of the RF and the following impact on the multi-bunch SASSE performance. Furthermore, HOM-based cavity misalignment measurements are performed and the deduction of misalignments from multi-bunch data is considered.

  5. Randomized trial for superiority of high field strength intra-operative magnetic resonance imaging guided resection in pituitary surgery.

    Science.gov (United States)

    Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S

    2017-03-01

    Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  7. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D

    2014-07-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm(3) or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using

  8. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    International Nuclear Information System (INIS)

    Martin, Peter R.; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm 3 or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was

  9. Point-of-Care Ultrasound for Pulmonary Concerns in Remote Spaceflight Triage Environments.

    Science.gov (United States)

    Johansen, Benjamin D; Blue, Rebecca S; Castleberry, Tarah L; Antonsen, Erik L; Vanderploeg, James M

    2018-02-01

    With the development of the commercial space industry, growing numbers of spaceflight participants will engage in activities with a risk for pulmonary injuries, including pneumothorax, ebullism, and decompression sickness, as well as other concomitant trauma. Medical triage capabilities for mishaps involving pulmonary conditions have not been systematically reviewed. Recent studies have advocated the use of point-of-care ultrasound to screen for lung injury or illness. The operational utility of portable ultrasound systems in disaster relief and other austere settings may be relevant to commercial spaceflight. A systematic review of published literature was conducted concerning the use of point-of-care pulmonary ultrasound techniques in austere environments, including suggested examination protocols for triage and diagnosis. Recent studies support the utility of pulmonary ultrasound examinations when performed by skilled operators, and comparability of the results to computed tomography and chest radiography for certain conditions, with important implications for trauma management in austere environments. Pulmonary injury and illness are among the potential health risks facing spaceflight participants. Implementation of point-of-care ultrasound protocols could aid in the rapid diagnosis, triage, and treatment of such conditions. Though operator-dependent, ultrasound, with proper training, experience, and equipment, could be a valuable tool in the hands of a first responder supporting remote spaceflight operations.Johansen BD, Blue RS, Castleberry TL, Antonsen EL, Vanderploeg JM. Point-of-care ultrasound for pulmonary concerns in remote spaceflight triage environments. Aerosp Med Hum Perform. 2018; 89(2):122-129.

  10. Endoscopic ultrasound with double-balloon endoscopy for the diagnosis of inverted Meckel’s diverticulum: a case report

    Directory of Open Access Journals (Sweden)

    Araki Akihiro

    2012-09-01

    Full Text Available Abstract Introduction Inverted Meckel’s diverticulum has usually been misdiagnosed in the cases based on computed tomography images presented in the literature. The final diagnosis was made intra-operatively or by pathology reports after surgery. Despite this, preoperative diagnosis could be made successfully by using endoscopic ultrasound with double-balloon endoscopy prior to surgery. Case presentation A 60-year-old Japanese woman with severe anemia complained of several episodes of black stool over the preceding 2 years. Abdominal computed tomography showed a 3.0-cm low-density tumor in the ileum, suggesting a diagnosis of intestinal lipoma. Examination of the tumor by endoscopic ultrasound with double-balloon endoscopy revealed a hypo-echoic layer corresponding to the muscularis propria, and a hyper-echoic layer corresponding to the fat tissue. These findings, which suggested that the tumor included areas outside the intestinal serosa, are not typical for a lipoma, despite the existence of a hyper-echoic layer corresponding to fatty tissue. We then considered a diagnosis of inverted Meckel’s diverticulum. Conclusion Lipoma and inverted Meckel’s diverticulum are difficult to differentially diagnose by computed tomography. Polypectomy is the preferred therapeutic approach when a lipoma is present; however, polypectomy in a patient with Meckel’s diverticulum requires full-thickness resection. Situations where polypectomy is performed without preparing for full-thickness resection can be avoided by first making a precise diagnosis using double-balloon endoscopy and endoscopic ultrasound.

  11. Use of transvaginal ultrasound in females with primary bladder neck obstruction. A preliminary study

    Directory of Open Access Journals (Sweden)

    Vikiela Galica

    2015-07-01

    Full Text Available Introduction and aim: The video-urodynamics study is the principal exam to establish a possible primary bladder neck obstruction (PBNO condition. While trans-rectal ultrasonography plays an important role in the evaluation of the low urinary tract symptoms (LUTS and the severity of bladder outlet obstruction (BOO in men, the use of the transvaginal ultrasound (TVUS in women with symptoms suggesting BOO remains unclear. We tried to check the utility of the TVUS in women with PBNO condition. Material and methods: We selected female patients which presented BOO without pelvic organ prolapse (POP. According to the data of the video-urodynamic exam we selected the patients with the suspicion of PBNO. A TVUS in basal and during micturition was performed before and after surgery. Results: TVUS showed a closed bladder neck bladder in basal condition and during micturition similarly to the fluoroscopic image during video-urodynamics. The mean distance from bladder neck to the vaginal mucosa resulted 1.3 cm in this patients. Conclusions: TVUS results worthy in the evaluation of patients with PBNO before and after surgery.

  12. Costs and role of ultrasound follow-up of polytrauma patients after initial computed tomography

    International Nuclear Information System (INIS)

    Maurer, M.H.; Winkler, A.; Powerski, M.J.; Elgeti, F.; Huppertz, A.; Roettgen, R.; Marnitz, T.; Wichlas, F.

    2012-01-01

    Purpose: To assess the costs and diagnostic gain of abdominal ultrasound follow-up of polytrauma patients initially examined by whole-body computed tomography (CT). Materials and Methods: A total of 176 patients with suspected multiple trauma (126 men, 50 women; age 43.5 ± 17.4 years) were retrospectively analyzed with regard to supplementary and new findings obtained by ultrasound follow-up compared with the results of exploratory FAST (focused assessment with sonography for trauma) at admission and the findings of whole-body CT. A process model was used to document the staff, materials, and total costs of the ultrasound follow-up examinations. Results: FAST yielded 26 abdominal findings (organ injury and/or free intra-abdominal fluid) in 19 patients, while the abdominal scan of whole-body CT revealed 32 findings in 25 patients. FAST had 81 % sensitivity and 100 % specificity. Follow-up ultrasound examinations revealed new findings in 2 of the 25 patients with abdominal injuries detected with initial CT. In the 151 patients without abdominal injuries in the initial CT scan, ultrasound follow-up did not yield any supplementary or new findings. The total costs of an ultrasound follow-up examination were EUR 28.93. The total costs of all follow-up ultrasound examinations performed in the study population were EUR 5658.23. Conclusion: Follow-up abdominal ultrasound yields only a low overall diagnostic gain in polytrauma patients in whom initial CT fails to detect any abdominal injuries but incurs high personnel expenses for radiological departments. (orig.)

  13. Multiparametric MRI in men with clinical suspicion of prostate cancer undergoing repeat biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2018-01-01

    Background Multiparametric magnetic resonance imaging (mpMRI) can improve detection of clinically significant prostate cancer (csPCa). Purpose To compare mpMRI score subgroups to systematic transrectal ultrasound-guided biopsies (TRUSbx) and prostate-specific antigen (PSA)-based findings...

  14. Sonographically guided posteromedial approach for intra-articular knee injections: a safe, accurate, and efficient method.

    Science.gov (United States)

    Tresley, Jonathan; Jose, Jean

    2015-04-01

    Osteoarthritis of the knee can be a debilitating and extremely painful condition. In patients who desire to postpone knee arthroplasty or in those who are not surgical candidates, percutaneous knee injection therapies have the potential to reduce pain and swelling, maintain joint mobility, and minimize disability. Published studies cite poor accuracy of intra-articular knee joint injections without imaging guidance. We present a sonographically guided posteromedial approach to intra-articular knee joint injections with 100% accuracy and no complications in a consecutive series of 67 patients undergoing subsequent computed tomographic or magnetic resonance arthrography. Although many other standard approaches are available, a posteromedial intra-articular technique is particularly useful in patients with a large body habitus and theoretically allows for simultaneous aspiration of Baker cysts with a single sterile preparation and without changing the patient's position. The posteromedial technique described in this paper is not compared or deemed superior to other standard approaches but, rather, is presented as a potentially safe and efficient alternative. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  16. Relation of size of seminal vesicles on ultrasound to premature ejaculation

    Directory of Open Access Journals (Sweden)

    Zhi-Wei Hong

    2017-01-01

    Full Text Available Myriad biological factors have been proposed to explain premature ejaculation (PE. However, data correlating PE with seminal vesicles (SVs are sparse. The study aimed to evaluate the relationship between the size of SV and PE. The cross-sectional study included 44 outpatients with PE and 44 volunteers without PE, and the size of SV was compared. Self-estimated intravaginal ejaculatory latency time, the Premature Ejaculation Diagnostic Tool (PEDT, the International Index of Erectile Function-15, and the National Institutes of Health-Chronic Prostatitis Symptom Index were used for assessment of symptoms. Compared to the control group, the PE group had significantly higher mean anterior-posterior diameter (APD of SV (P < 0.001. The optimal mean APD of SV cutoff level was 9.25 mm for PE. In the PE group, PEDT was also higher with a mean APD of SV ≥9.25 mm compared with mean APD of SV <9.25 mm. PEDT was significantly correlated with the mean APD of SV (r = 0.326, P = 0.031. The seminal plasma proteins were compared between six PE and six matched control cases by mass spectrometry and it was shown that 102 proteins were at least 1.5-fold up- or down-regulated. Among them, GGT1, LAMC1, and APP were significantly higher in the PE group. These results indicated that men with a larger mean APD of SV might have a higher PEDT score. Transrectal ultrasound of SV should be considered in the evaluation of patients with premature ejaculation. SV might be a potential target for the treatment of patients with PE and ultrasound change in SV.

  17. Studies of nonlinear ultrasound propagation: safety considerations in the use of ultrasound for medical diagnosis - nonlinear propagation

    International Nuclear Information System (INIS)

    Egerton, B.; Barnett, S.; Vella, G.

    1994-01-01

    Diagnostic ultrasound is an established imaging modality without any documented harmful effects. New developments such as pulsed Doppler and intracavity investigations may result in increases in ultrasound exposures which could cause harm. Thermal mechanisms and cavitation may become relevant sources of bioeffects. The preliminary study described here investigates the distribution and amplitude of harmonics generated through nonlinear propagation of ultrasound in water. Knowledge of harmonic attenuation will help predict sites of enhanced heating and enable accurate modelling of clinical situations. This presentation is concerned with thermal safety guidelines, their relationship to a typical ultrasound beam profile for a single, medium focussed, transducer operating in water and possible sites of enhanced heating due to nonlinear propagation effects. Measurements were made of the amplitudes of the harmonics generated by the nonlinear propagation of ultrasound in water. The amplitudes of the harmonics were detected up to frequencies of 35 MHz and displayed using Fast Fourier Transform facilities within the oscilloscope. The nonlinearity parameter of the ultrasonic waveforms has been identified as an important factor in thermal effects of ultrasound interactions. The appearance of nonlinear distortion is shown to be dependant on the peak compressional pressure and distance from the ultrasound source. 20 refs., 2 figs

  18. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  19. Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom

    International Nuclear Information System (INIS)

    Lee, Song; Choi, Joon Il; Park, Michael Yong; Yeo, Dong Myung; Byun, Jae Young; Jung, Seung Eun; Rha, Sung Eun; Oh, Soon Nam; Lee, Young Joon

    2014-01-01

    To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a pass or fail decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended.

  20. Schwannoma in the porta hepatis - laparoscopic excision under laparoscopic ultrasound guidance.

    Science.gov (United States)

    Sebastian, Maciej; Sroczyński, Maciej; Donizy, Piotr; Rudnicki, Jerzy

    2017-09-01

    Schwannomas are usually benign tumors attached to peripheral nerves and are rarely found in the gastrointestinal tract. Schwannomas in the porta hepatis are extremely rare, with only 15 cases described in the literature to date. A 22-year-old female patient presented with colicky upper abdominal pain lasting 3 months. Magnetic resonance imaging of the abdominal cavity revealed a tumor in the porta hepatis. The patient was qualified for laparoscopy. The tumor was totally excised laparoscopically under guidance of laparoscopic ultrasound without intra- or postoperative complications. Postoperative histopathological examination confirmed the porta hepatic schwannoma. The patient recovered uneventfully with very good cosmetic results. In the follow-up period of 5 months we have not observed any abdominal or general health problems. The present case is the first report in the world of laparoscopic ultrasound guided laparoscopic excision of a porta hepatic schwannoma.

  1. Intra-abdominal fat measurement by ultrasonography: association with anthropometry and metabolic syndrome in adolescents.

    Science.gov (United States)

    Novais, Rommel L R; Café, Ana Carolina C; Morais, Aisha A; Bila, Wendell C; Santos, Gilson D da S; Lopes, Carlos Alexandre de O; Belo, Vinícius S; Romano, Márcia Christina C; Lamounier, Joel A

    2018-04-27

    To associate intra-abdominal fat thickness measured by ultrasonography to the factors related to metabolic syndrome and to determine cutoff points of intra-abdominal fat measurement associated with a greater chance of metabolic syndrome in adolescents. This was a cross-sectional study, with 423 adolescents from public schools. Intra-abdominal fat was measured by ultrasonography. Anthropometric data were collected, and biochemical analyses were performed. Intra-abdominal fat was measured by ultrasonography, showing a statistically significant association with the diagnosis of metabolic syndrome (p=0.037), body mass index (p<0.001), elevated triglyceride levels (p=0.012), decreased plasma HDL levels (p=0.034), and increased systemic blood pressure values (p=0.023). Cutoff values of intra-abdominal fat thickness measurements were calculated by ultrasound to estimate the individuals most likely to develop metabolic syndrome. In the logistic regression models, the cutoff values that showed the highest association with metabolic syndrome in males were 4.50, 5.35, 5.46, 6.24, and 6.50cm for the ages of 14, 15, 16, 17, and 18/19 years, respectively. In the female gender, the cutoff values defined for the same age groups were 4.46, 4.55, 4.45, 4.90, and 6.46cm. In an overall analysis using the ROC curve, without gender and age stratification, the cut-off of 3.67cm showed good sensitivity, but low specificity. Ultrasonography is a useful method to estimate intra-abdominal adipose tissue in adolescents, which is associated with the main factors related to obesity and metabolic syndrome. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. Simulated versus realistic intra operative radiation therapy (I.O.R.T.) treatment in operating room: from knowledge of stray radiation to action

    International Nuclear Information System (INIS)

    Andreoli, S.; Moretti, R.; Catalano, M.; Locatelli, F.

    2006-01-01

    Intra-Operative Radiation Therapy (I.O.R.T.) is carried out with electron beams produced by a Linac (Linear Accelerator) generally used for conventional radiotherapy with external beam, or by dedicated accelerators that can be employed directly into an operating room. I.O.R.T. refers to the application of radiation during a surgical intervention, after the removal of a neoplastic mass. I.O.R.T. uses on the tumour area a direct irradiation, for the possible localisation of sub-clinic illness or macroscopic residue in the case of non-radical resection. Intra-Operative Radiotherapy foresees a single session only, generally preceded or followed by radiotherapy with external beam. It allows the achievement of a selective radiation boost on the tumour volume. In some cases, it can also be used as a one-time/stand alone treatment in initial cancer of small volume, or in unresectable malignancies for palliative purpose. The technical advantages of I.O.R.T. consist in the direct visual control of the target volume, and in the possibility to protect the healthy tissues by moving them away from the path of the radiation beam. The use of electron beams allows the administration of a homogeneous dose to a selected layer of tissues surrounding the tumour. The following professional staff forms the Operative Group: radiation oncologist, surgeon, anaesthetist, medical physicist, radiation technologist, nurse.The choice of a simulation geometry very similar to the clinical situation allows to evaluate radioprotection data very close to the real situation. For a fixed layout, an anthropomorphic phantom was positioned on the operating bed and a breast I.O.R.T. treatment was simulated positioning all the accessories of the operating room in their typical positions. A detailed dose mapping was performed with a Victoreen 450P ionisation chamber and with environment film-dosimeter on the walls of the operating room during the simulation of the clinical treatment. The simulation appears

  3. Salvage High-intensity Focused Ultrasound for the Recurrent Prostate Cancer after Radiotherapy

    International Nuclear Information System (INIS)

    Shoji, S.; Nakano, M.; Omata, T.; Harano, Y.; Nagata, Y.; Uchida, T.; Usui, Y.; Terachi, T.

    2010-01-01

    To investigate the use of minimally invasive high-intensity focused ultrasound (HIFU) as a salvage therapy in men with localized prostate cancer recurrence following external beam radiotherapy (EBRT), brachytherapy or proton therapy. A review of 20 cases treated using the Sonablate registered 500 HIFU device, between August 28, 2002 and September 1, 2009, was carried out. All men had presumed organ-confined, histologically confirmed recurrent prostate adenocarcinoma following radiation therapy. All men with presumed, organ-confined, recurrent disease following EBRT in 8 patients, brachytherapy in 7 patients or proton therapy in 5 patients treated with salvage HIFU were included. The patients were followed for a mean (range) of 16.0 (3-80) months. Biochemical disease-free survival (bDFS) rates in patients with low-intermediate and high risk groups were 86% and 50%, respectively. Side-effects included urethral stricture in 2 of the 16 patients (13%), urinary tract infection or dysuria syndrome in eight (26%), and urinary incontinence in one (6%). Recto-urethral fistula occurred in one patient (6%). Transrectal HIFU is an effective treatment for recurrence after radiotherapy especially in patients with low- and intermediate risk groups.

  4. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  5. Comparison of intra-articular bupivacaine-morphine with bupivacaine-tenoxicam combinations on post-operative analgesia in patients with arthroscopic meniscectomy: a prospective, randomised study.

    Science.gov (United States)

    Sanel, Selim; Arpaz, Osman; Unay, Koray; Turkmen, Ismail; Simsek, Selcuk; Ugutmen, Ender

    2016-03-01

    There are many alternatives for post-operative pain relief in patients who have had general anaesthesia. The aim of this study was to evaluate the efficacy of intra-articular bupivacaine + morphine and bupivacaine + tenoxicam applications in post-operative pain control in patients undergoing knee arthroscopy with general anaesthesia. This was a prospective study. Standard anaesthesia procedures were applied to each patient, and the 240 patients chosen at random were then divided into two groups. Each group received a different combination of drugs for this double-blind study. The first group (group A: 120 patients) received 0.5% bupivacaine 100 mg + tenoxicam 20 mg (22 ml); the second group (group B) received 0.5% bupivacaine 100 mg + morphine 2 mg (22 ml); both groups received their drugs at the end of the intra-articular operation before tourniquet deflation. Before the operation, patients were asked about their post-operative pain at particular periods over the following 24 hours using the visual analogue scale (VAS) and the numeric rating scale (NRS). An additional analgaesic requirement and possible side effects were also recorded. Group A patients needed analgaesics sooner after operation than patients in group B. In Group B, VAS and NRS values were statistically higher compared with group A at the 12th hour. There were also fewer side effects seen in group A versus group B. Effective and reliable results were obtained in post-operative pain control in bupivacaine added to the morphine or tenoxicam groups following arthroscopic meniscectomy. In the tenoxicam group, patients reported less pain, fewer side effects and less need for analgesics at 12 hours after the operation. level 1, therapeutic, randomised, multicentric study.

  6. Comparison of two techniques of transrectal ultrasonography for the assessment of local extent of polypoid tumours of the rectum

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1996-01-01

    The capability of transrectal ultrasonography (TRUS) to differentiate between benign and malignant rectal polyps was evaluated. Digital palpation and sigmoidoscopy were followed by TRUS with a 7.5-MHz linear-array transducer, in a blinded design. In the second part of the study the procedure...... indicated 20 of 49 adenomas to be carcinomas, compared with 4 out of 49 by digital examination (P benign and malignant...

  7. Evaluating the Learning Curve for Percutaneous Nephrolithotomy under Total Ultrasound Guidance.

    Directory of Open Access Journals (Sweden)

    Yan Song

    Full Text Available To investigate the learning curve of percutaneous nephrolithotomy under total ultrasound guidance.One hundred and twenty consecutive PCNL operations under total ultrasound guidance performed by a novice surgeon in a tertiary referral center were studied. Operations were analyzed in cohorts of 15 to determine when a plateau was reached for the variables such as operation duration, ultrasound screening time, tract dilation time, stone-free rate and complication rate. Comparison was made with the results of a surgeon who had performed more than 1000 PCNLs. Fluoroscopy was not used at all during procedure.The mean operation time dropped from 82.5 min for the first 15 patients to a mean of 64.7 min for cases 46 through 60(P = 0.047. The ultrasound screening time was a peak of 6.4 min in the first 15 cases, whereas it dropped to a mean of 3.9 min for cases 46 through 60(P = 0.01. The tract dilation time dropped from 4.9 min for the first 15 patients to a mean of 3.8 min for cases 46 through 60(P = 0.036. The senior surgeon had a mean operating time, screening time and tract dilation time equivalent to those of the novice surgeon after 60 cases. There was no significant difference in stone free rate and complication rate.The competence of ultrasound guided PCNL is reached after 60 cases with good stone free rate and without major complications.

  8. Inoculation of Sphingobacterium multivorum in the prostate by prostate biopsy

    DEFF Research Database (Denmark)

    Kjær Nielsen, Torben; Pinholt, Mette; Nørgaard, Nis

    2014-01-01

    Abstract This report describes three cases of infection with Sphingobacterium multivorum after transrectal ultrasound-guided prostate biopsy. The pathogen is ubiquitous in water and soil but has been described fewer than 10 times causing infections in humans. An infection hygiene evaluation...

  9. Ultrasound speckle reduction based on fractional order differentiation.

    Science.gov (United States)

    Shao, Dangguo; Zhou, Ting; Liu, Fan; Yi, Sanli; Xiang, Yan; Ma, Lei; Xiong, Xin; He, Jianfeng

    2017-07-01

    Ultrasound images show a granular pattern of noise known as speckle that diminishes their quality and results in difficulties in diagnosis. To preserve edges and features, this paper proposes a fractional differentiation-based image operator to reduce speckle in ultrasound. An image de-noising model based on fractional partial differential equations with balance relation between k (gradient modulus threshold that controls the conduction) and v (the order of fractional differentiation) was constructed by the effective combination of fractional calculus theory and a partial differential equation, and the numerical algorithm of it was achieved using a fractional differential mask operator. The proposed algorithm has better speckle reduction and structure preservation than the three existing methods [P-M model, the speckle reducing anisotropic diffusion (SRAD) technique, and the detail preserving anisotropic diffusion (DPAD) technique]. And it is significantly faster than bilateral filtering (BF) in producing virtually the same experimental results. Ultrasound phantom testing and in vivo imaging show that the proposed method can improve the quality of an ultrasound image in terms of tissue SNR, CNR, and FOM values.

  10. Effect of Intra Vitreal Injection of Bevacizumab on Intra-Occular Pressure

    International Nuclear Information System (INIS)

    Jaffar, S.; Tayyab, A.; Matin, Z. I.; Masrur, A.; Naqaish, R.

    2016-01-01

    Background: Bevacizumab has been in use as a therapeutic agent for macular oedema for several years. While its efficacy has been well documented, its use has been shown to cause a transient rise in the intra-ocular pressure. The aim of this study was to evaluate the long term effect of intra-vitreal injection of Bevacizumab on Intra-ocular pressure. Methods: One hundred eyes (n=100) of one hundred patients, requiring intra-vitreal injection of Bevacizumab for diabetic macular oedema were recruited from Shifa Foundation Community Health Centre (SFCHC) between January and December 2014. Patients of glaucoma, ocular hyper-tension, known allergy to Bevacizumab or had injections of Bevacizumab prior to the study were excluded. Intra-ocular pressure was measured using a Goldmann applanation tonometer, prior to, and at six and twelve months after the injection. The pre- and post- injection Intra-ocular pressure was entered into the database. Test of significance was applied to investigate whether there was a significant change in intra-ocular pressure after the injection. Results: The mean age of the patient was 56.97 years (±14.97). The mean intra-ocular pressure was 13.86 (±3.16) mmHg before injection, while post-injection mean Intra-Ocular pressure was 14.21 (±3.12) mmHg and 13.79 (±3.07) at six and twelve months respectively. Between baseline and six months there was a statistically significant difference in intra-ocular pressure (p=0.03), while no significant difference existed in the intra-ocular pressure between baseline and twelve months (p=0.92). Conclusion: Intra-vitreal injection of Bevacizumab is associated with a statically significant rise in intra-ocular pressure at six months, while no significant difference was seen at twelve months compared to baseline. (author)

  11. Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds

    OpenAIRE

    Lediju Bell, Muyinatu A.; Kuo, Nathanael; Song, Danny Y.; Boctor, Emad M.

    2013-01-01

    Prostate brachytherapy, administered by implanting tiny radioactive seeds to treat prostate cancer, currently relies on transrectal ultrasound imaging for intraoperative visualization of the metallic seeds. Photoacoustic (PA) imaging has been suggested as a feasible alternative to ultrasound imaging due to its superior sensitivity to metal surrounded by tissue. However, PA images suffer from poor contrast when seeds are distant from the light source. We propose a transperineal light delivery ...

  12. Reconstructions in ultrasound modulated optical tomography

    KAUST Repository

    Allmaras, Moritz; Bangerth, Wolfgang

    2011-01-01

    We introduce a mathematical model for ultrasound modulated optical tomography and present a simple reconstruction scheme for recovering the spatially varying optical absorption coefficient from scanning measurements with narrowly focused ultrasound signals. Computational results for this model show that the reconstruction of sharp features of the absorption coefficient is possible. A formal linearization of the model leads to an equation with a Fredholm operator, which explains the stability observed in our numerical experiments. © de Gruyter 2011.

  13. Ultrasound waiting lists: rational queue or extended capacity?

    Science.gov (United States)

    Brasted, Christopher

    2008-06-01

    The features and issues regarding clinical waiting lists in general and general ultrasound waiting lists in particular are reviewed, and operational aspects of providing a general ultrasound service are also discussed. A case study is presented describing a service improvement intervention in a UK NHS hospital's ultrasound department, from which arises requirements for a predictive planning model for an ultrasound waiting list. In the course of this, it becomes apparent that a booking system is a more appropriate way of describing the waiting list than a conventional queue. Distinctive features are identified from the literature and the case study as the basis for a predictive model, and a discrete event simulation model is presented which incorporates the distinctive features.

  14. Randomised study on single stage laparo-endoscopic rendezvous (intra-operative ERCP) procedure versus two stage approach (Pre-operative ERCP followed by laparoscopic cholecystectomy) for the management of cholelithiasis with choledocholithiasis.

    Science.gov (United States)

    Sahoo, Manash Ranjan; Kumar, Anil T; Patnaik, Aashish

    2014-07-01

    The 'Rendezvous' technique consists of laparoscopic cholecystectomy (LC) standards with intra-operative cholangiography followed by endoscopic sphincterotomy. The sphincterotome is driven across the papilla through a guidewire inserted by the transcystic route. In this study, we intended to compare the two methods in a prospective randomised trial. From 2005 to 2012, we enrolled 83 patients with a diagnosis of cholecysto-choledocolithiasis. They were randomised into two groups. In 'group-A',41 patients were treated with two stages management, first by pre-operative endoscopic retrograde cholangiopancreatography (ERCP) and common bile duct (CBD) clearance and second by LC. In 'group-B', 42 patients were treated with LC and intra-operative cholangiography; and when diagnosis of choledocholithiasis was confirmed, patients had undergone one stage management of by Laparo-endoscopic Rendezvous technique. In arm-A and arm-B groups, complete CBD clearance was achieved in 29 and 38 patients, respectively. Failure of the treatment in arm-A was 29% and in arm-B was 9.5%. In arm-A, selective CBD cannulation was achieved in 33 cases (80.5%) and in arm-B in 39 cases (93%). In arm-Agroup, post-ERCP hyperamylasia was presented in nine patients (22%) and severe pancreatitis in five patients (12%) versus none of the patients (0%) in arm-B group, respectively. Mean post-operative hospital stay in arm-A and arm-B groups are 10.9 and 6.8 days, respectively. One stage laparo-endoscopic rendezvous approach increases selective cannulation of CBD, reduces post-ERCP pancreatitis, reduces days of hospital stay, increases patient's compliance and prevents unnecessary intervention to CBD.

  15. SU-E-J-135: An Investigation of Ultrasound Imaging for 3D Intra-Fraction Prostate Motion Estimation

    Energy Technology Data Exchange (ETDEWEB)

    O' Shea, T; Harris, E; Bamber, J [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton, Greater London (United Kingdom); Evans, P [Centre for Vision, Speech and Signal Processing, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford (United Kingdom)

    2014-06-01

    Purpose: This study investigates the use of a mechanically swept 3D ultrasound (US) probe to estimate intra-fraction motion of the prostate during radiation therapy using an US phantom and simulated transperineal imaging. Methods: A 3D motion platform was used to translate an US speckle phantom while simulating transperineal US imaging. Motion patterns for five representative types of prostate motion, generated from patient data previously acquired with a Calypso system, were using to move the phantom in 3D. The phantom was also implanted with fiducial markers and subsequently tracked using the CyberKnife kV x-ray system for comparison. A normalised cross correlation block matching algorithm was used to track speckle patterns in 3D and 2D US data. Motion estimation results were compared with known phantom translations. Results: Transperineal 3D US could track superior-inferior (axial) and anterior-posterior (lateral) motion to better than 0.8 mm root-mean-square error (RMSE) at a volume rate of 1.7 Hz (comparable with kV x-ray tracking RMSE). Motion estimation accuracy was poorest along the US probe's swept axis (right-left; RL; RMSE < 4.2 mm) but simple regularisation methods could be used to improve RMSE (< 2 mm). 2D US was found to be feasible for slowly varying motion (RMSE < 0.5 mm). 3D US could also allow accurate radiation beam gating with displacement thresholds of 2 mm and 5 mm exhibiting a RMSE of less than 0.5 mm. Conclusion: 2D and 3D US speckle tracking is feasible for prostate motion estimation during radiation delivery. Since RL prostate motion is small in magnitude and frequency, 2D or a hybrid (2D/3D) US imaging approach which also accounts for potential prostate rotations could be used. Regularisation methods could be used to ensure the accuracy of tracking data, making US a feasible approach for gating or tracking in standard or hypo-fractionated prostate treatments.

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  17. Validation of Ultrasound Imaging to Rule-out Thoracic Trauma on the International Space Station

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2006-01-01

    Introduction: Aboard the International Space Station (ISS) an intra-thoracic injury may be disastrous to the crew member if the diagnosis is missed or even delayed. Pneumothorax and hemothorax commonly seen in trauma patients; the diagnosis is usually confirmed by chest X-ray or computed tomography. In this study, the ability of ultrasound to rule out pneumothorax by the presence "lung sliding" and hemothorax by the absence of pleural fluid was validated. Methods: The research activities were approved by the NASA Johnson Space Center Committee for the Protection of Human Subjects, and the participating crewmembers signed informed consent prior to the activity. ISS crewmembers received 2-hours of "hands on" ultrasound training 8 months prior to the on-orbit ultrasound exam. Baseline ultrasound images of the thorax were acquired on the crewmebers of Increment 8 and 9 prior to launch from Bakonur, Russia. Ultrasound examination of the thorax were performed on crewmembers at 30 day intervals (n=??) throughout their flight. Post flight images were acquired on or about landing day 10. Ultrasound images were acquired using the ISS Health Research Facility ultrasound system and examined by experts on the ground to rule out the presence of pneumothorax and hemothorax. Results: The presence of "lung sliding" which excludes pneumothorax, was seen in all subjects. The absence of pleural fluid, which excludes hemothorax was seen in all subjects. The optimal position between sonographer and patient under microgravity conditions and the amount and type of training for a non-physician crew medical officer for these procedures was also established for this procedure. Conclusion: Ultrasound can be performed on orbit under microgravity condition to rule thoracic trauma, such as pneumothorax and hemothorax.

  18. [Inflammatory pseudotumour of the liver. Importance of intra-operative histopathology].

    Science.gov (United States)

    Onieva-González, Francisco Gabriel; Galeano-Díaz, Francisco; Matito-Díaz, María José; López-Guerra, Diego; Fernández-Pérez, Juana; Blanco-Fernández, Gerardo

    2015-01-01

    Inflammatory pseudotumour is a rare entity, considered benign, and characterised by inflammatory cell mesenchymal proliferation. The case is presented 70 year-old man with fever of unknown origin syndrome. He was diagnosed with liver abscesses (one segment IV, adjacent to gallbladder fundus and segment VI), who progressed slowly after antibiotic treatment. In the absence of a diagnosis, although fine needle puncture-aspiration and different imaging tests were performed, elective surgery was decided. The intra-operative histopathology reported the existence of an inflammatory pseudotumour. Inflammatory pseudotumours are clinically classified into different types according to their aetiology, varying therapeutic management based on the same. It is very difficult to diagnose because of the absence of symptoms, blood disorders, or specific radiological findings. Definitive diagnosis often requires histopathological confirmation, in most cases by percutaneous liver puncture, but sometimes exploratory laparotomy or even performing a hepatectomy for confirmation is necessary. The natural history of inflammatory pseudotumour is its regression; thus conservative management may be used through regular checks until resolution, or can be treated with antibiotics, anti-inflammatories and even corticosteroids. Surgical resection is indicated for persistent unresolved systemic symptoms despite medical treatment, in those situations where growth is evident, with or without symptoms, when involving the hepatic hilum, and finally, in case where the possibility of malignancy cannot be ruled out. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  19. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.

    Science.gov (United States)

    Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M

    2017-02-01

    BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  20. Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.

    Science.gov (United States)

    Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J

    2018-01-01

    Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.

  1. Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

    International Nuclear Information System (INIS)

    Lawton, Colleen A.; Hunt, Daniel; Lee, W. Robert; Gomella, Leonard; Grignon, David; Gillin, Michael; Morton, Gerard; Pisansky, Thomas M.; Sandler, Howard

    2011-01-01

    Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I 125 implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of ≤10 ng/ml; and a Gleason score of ≤6. All patients underwent transrectal ultrasound-guided radioactive I 125 seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable

  2. A passive wireless ultrasound pitch–catch system

    International Nuclear Information System (INIS)

    Zahedi, F; Yao, J; Huang, H

    2015-01-01

    This paper exploits amplitude modulation and demodulation to achieve a passive wireless ultrasound pitch–catch system consisting of a wireless interrogator and a combination of a wireless actuator and a sensor mounted on a structure. The wireless interrogator operates in two modes, i.e. the generation and sensing modes. At the generation mode, the interrogator transmits two microwave signals; one is amplitude modulated with the ultrasound excitation signal while the other is a continuous-wave carrier signal. Once received by the wireless actuator, the amplitude modulated signal is demodulated using the carrier signal to recover the ultrasound excitation signal, which is then supplied to a piezoelectric wafer actuator for ultrasound generation. Subsequently, the interrogator is switched to the sensing mode by transmitting a carrier signal with a different frequency. Once received by the wireless sensor, this carrier signal is modulated with the ultrasound sensing signal acquired by the piezoelectric wafer sensor to produce an amplitude modulated microwave signal, which can then be wirelessly transmitted and demodulated by the interrogator to recover the original ultrasound sensing signal. The principle and implementation of the wireless ultrasound pitch–catch system as well as the data processing of the wirelessly received sensing signal are described. Experiment results validating wireless ultrasound generation and sensing from a distance of 0.5 m are presented. (paper)

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  4. T cell lymphoblastic lymphoma/leukemia within an adrenocorticotropic hormone and thyroid stimulating hormone positive pituitary adenoma: A cytohistological correlation emphasizing importance of intra-operative squash smear.

    Science.gov (United States)

    Gupta, Rakesh K; Saran, Ravindra K; Srivastava, Arvind K; Jagetia, Anita; Garg, Lalit; Sharma, Mehar C

    2017-08-01

    We present a rare case of primary pituitary T cell lymphoma/leukemia (T-LBL) in association with adrenocorticotropic hormone (ACTH) and thyroid stimulating hormone (TSH) expressing pituitary adenoma in a 55-year-old woman highlighting the importance of intra-operative squash smears examination. The patient presented with complaints of headache, diminution of vision and recent onset altered sensorium. MRI revealed a mass lesion in the sellar-suprasellar region with non-visualization of pituitary gland separately, extending to involve adjacent structures diagnosed as invasive pituitary macroadenoma. Intra-operative tissue was sent for squash smear examination. The cytology showed a tumor comprising of sheets of immature lymphoid cells intermixed with clusters of pituitary acinar cells with many mitoses and tingible body macrophages. A diagnosis of presence of immature lymphoid cells within the pituitary was offered and differentials of infiltration by lymphoma cells from systemic disease versus primary central nervous lymphoma-like lymphoma arising in the pituitary adenoma were considered. Later paraffin section examination and immunohistochemistry corroborated with the squash findings and a final diagnosis of primary pituitary T cell lymphoma/leukemia in association with ACTH and TSH expressing pituitary adenoma was made. To date, only six cases of primary pituitary T cell lymphomas, including three T-LBL cases, have been reported. This is the seventh case and first one additionally describing cytohistological correlation and importance of intra-operative cytology. © 2017 Japanese Society of Neuropathology.

  5. Practical recommendations for performing ultrasound scanning in the urological and andrological fields

    Directory of Open Access Journals (Sweden)

    Pasquale Martino

    2014-03-01

    Full Text Available Aim: US scanning has been defined as the urologist’s stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Methods: Members of the Imaging Working Group of the Italian Society of Urology (SIU in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Results: Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Conclusions: Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter

  6. Practical recommendations for performing ultrasound scanning in the urological and andrological fields.

    Science.gov (United States)

    Martino, Pasquale; Galosi, Andrea Benedetto; Bitelli, Marco; Consonni, Paolo; Fiorini, Fulvio; Granata, Antonio; Gunelli, Roberta; Liguori, Giovanni; Palazzo, Silvano; Pavan, Nicola; Scattoni, Vincenzo; Virgili, Guido

    2014-03-28

    US scanning has been defined as the urologist's stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Members of the Imaging Working Group of the Italian Society of Urology (SIU) in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN) identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter-observer variability is a well known limitation. These

  7. EAMJ The Diagnostic Sep 09.indd

    African Journals Online (AJOL)

    East African Medical Journal Vol. 86 No. 9 September 2009. DIAGNOSTIC VALUES OF DIGITAL RECTAL EXAMINATION, PROSTATE SPECIFIC ANTIGEN AND TRANS-RECTAL. ULTRASOUND IN MEN WITH PROSTATISM. J. P. Manyahi, MD, MMed (Surg), MSc (Urol), Peramiho Hospital, P. O. Box 19, Peramiho.

  8. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  10. Understanding of percutaneous puncture under guidance of ultrasound in treating peritoneal and perinephritic abscess

    International Nuclear Information System (INIS)

    Huang Liying; Wang Jiagang

    2010-01-01

    Objective: To explore the clinical value of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess. Methods: To summarize 68 patients with peritoneal abscess underwent percutaneous puncture under guidance of ultrasound to analyse the method of operation and therapeutic effect. Results: effective power of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess was 96.8%. Conclusion: Percutaneous puncture under guidance of ultrasound in treating peritoneal abscess may avoid injury induced by blinded puncture, with characteristic of easier operation, slighter trauma. higher safety, significant therapeutic effect, and can be spreaded to the clinical application. (authors)

  11. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  13. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  14. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  15. Intra-site Secure Transport Vehicle test and evaluation

    International Nuclear Information System (INIS)

    Scott, S.

    1995-01-01

    In the past many DOE and DoD facilities involved in handling nuclear material realized a need to enhance the safely and security for movement of sensitive materials within their facility, or ''intra-site''. There have been prior efforts to improve on-site transportation; however, there remains a requirement for enhanced on-site transportation at a number of facilities. The requirements for on-site transportation are driven by security, safety, and operational concerns. The Intra-site Secure Transport Vehicle (ISTV) was designed to address these concerns specifically for DOE site applications with a standardized vehicle design. This paper briefly reviews the ISTV design features providing significant enhancement of onsite transportation safety and security, and also describes the test and evaluation activities either complete of underway to validate the vehicle design and operation

  16. Data quality and practical challenges of thyroid volume assessment by ultrasound under field conditions - observer errors may affect prevalence estimates of goitre

    Directory of Open Access Journals (Sweden)

    Torheim Liv E

    2010-12-01

    Full Text Available Abstract Background The ultrasonographic estimation of thyroid size has been advocated as being more precise than palpation to diagnose goitre. However, ultrasound also requires technical proficiency. This study was conducted among Saharawi refugees, where goitre is highly prevalent. The objectives were to assess the overall data quality of ultrasound measurements of thyroid volume (Tvol, including the intra- and inter-observer agreement, under field conditions, and to describe some of the practical challenges encountered. Methods In 2007 a cross-sectional study of 419 children (6-14 years old and 405 women (15-45 years old was performed on a population of Saharawi refugees with prevalent goitre, who reside in the Algerian desert. Tvol was measured by two trained fieldworkers using portable ultrasound equipment (examiner 1 measured 406 individuals, and examiner 2, 418 individuals. Intra- and inter-observer agreement was estimated in 12 children selected from the study population but not part of the main study. In the main study, an observer error was found in one examiner whose ultrasound images were corrected by linear regression after printing and remeasuring a sample of 272 images. Results The intra-observer agreement in Tvol was higher in examiner 1, with an intraclass correlation coefficient (ICC of 0.97 (95% CI: 0.91, 0.99 compared to 0.86 (95% CI: 0.60, 0.96 in examiner 2. The ICC for inter-observer agreement in Tvol was 0.38 (95% CI: -0.20, 0.77. Linear regression coefficients indicated a significant scaling bias in the original measurements of the AP and ML diameter and a systematic underestimation of Tvol (a product of AP, ML, CC and a constant. The agreement between re-measured and original Tvol measured by ICC (95% CI was 0.76 (0.71, 0.81. The agreement between re-measured and corrected Tvol measured by ICC (95% CI was 0.97 (0.96, 0.97. Conclusions An important challenge when using ultrasound to assess thyroid volume under field

  17. The Intra Uterine Morcellator: a new hysteroscopic operating technique to remove intrauterine polyps and myomas.

    Science.gov (United States)

    Emanuel, Mark Hans; Wamsteker, Kees

    2005-01-01

    A new hysteroscopic operating technique was compared retrospectively with conventional resectoscopy. Retrospective comparison (Canadian Task Force Classification II-2). Gynecology department of a university-affiliated teaching hospital. Fifty-five women, 27 with endometrial polyps and 28 with submucous myomas. Patients were treated with a prototype of the Intra Uterine Morcellator (IUM). This cutting device, 35 cm in length, was inserted into a straight working channel of a 90-mm hysteroscope. The major advantages were ease of removal of tissue fragments through the instrument and the use of saline solution instead of electrolyte-free solutions used in monopolar high-frequency resectoscopy. The mean operating time was 8.7 minutes (95% CI: 7.3-10.1) for the removal of endometrial polyps compared with 30.9 minutes (CI: 27.0-34.8) for resectoscopy, and 16.4 minutes (CI: 12.6-20.2) for submucous myomas compared with 42.2 minutes (CI: 39.7-44.7) for resectoscopy. All procedures were uneventful. This new technique is faster, and it appears to be easier to perform. Therefore, it can be expected to result in fewer fluid-related complications and to lead to a shorter learning curve when compared with conventional resectoscopy.

  18. Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate

    OpenAIRE

    Dimos Baltas; George Sakas; Pawel Zogal; Vasiliki Kefala; Zaira Katsilieri; Saeed Butt; Natasa Milickovic; Stefanos Diamantopoulos

    2011-01-01

    Purpose This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established water-bath based quality assurance (QA) procedures is presented. Material and methods Image acquisitions of an ultrasound QA setup were carried out at 5...

  19. A novel intra-operative, high-resolution atrial mapping approach.

    Science.gov (United States)

    Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S

    2015-12-01

    A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.

  20. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  1. Randomised study on single stage laparo-endoscopic rendezvous (intra-operative ERCP procedure versus two stage approach (Pre-operative ERCP followed by laparoscopic cholecystectomy for the management of cholelithiasis with choledocholithiasis

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Introduction : The ′Rendezvous′ technique consists of laparoscopic cholecystectomy (LC standards with intra-operative cholangiography followed by endoscopic sphincterotomy. The sphincterotome is driven across the papilla through a guidewire inserted by the transcystic route. In this study, we intended to compare the two methods in a prospective randomised trial. Materials And Methods: From 2005 to 2012, we enrolled 83 patients with a diagnosis of cholecysto-choledocolithiasis. They were randomised into two groups. In ′group-A′,41 patients were treated with two stages management, first by pre-operative endoscopic retrograde cholangiopancreatography (ERCP and common bile duct (CBD clearance and second by LC. In ′group-B′, 42 patients were treated with LC and intra-operative cholangiography; and when diagnosis of choledocholithiasis was confirmed, patients had undergone one stage management of by Laparo-endoscopic Rendezvous technique. Results: In arm-A and arm-B groups, complete CBD clearance was achieved in 29 and 38 patients, respectively. Failure of the treatment in arm-A was 29% and in arm-B was 9.5%. In arm-A, selective CBD cannulation was achieved in 33 cases (80.5% and in arm-B in 39 cases (93%. In arm-Agroup, post-ERCP hyperamylasia was presented in nine patients (22% and severe pancreatitis in five patients (12% versus none of the patients (0% in arm-B group, respectively. Mean post-operative hospital stay in arm-A and arm-B groups are 10.9 and 6.8 days, respectively. Conclusion: One stage laparo-endoscopic rendezvous approach increases selective cannulation of CBD, reduces post-ERCP pancreatitis, reduces days of hospital stay, increases patient′s compliance and prevents unnecessary intervention to CBD.

  2. MRI of the prostate: potential role of robots

    NARCIS (Netherlands)

    Fütterer, Jurgen J.; Misra, Sarthak; Macura, Katarzyna J.

    2010-01-01

    Prostate cancer is the most frequently diagnosed malignancy in the male population. Transrectal ultrasound- guided biopsy is still the imaging modality of choice in detecting prostate cancer. However, with prostate cancer being detected at an earlier stage, most prostate cancers tend to be isoechoic

  3. Evaluation of hyperglycaemic response to intra-operative dexamethasone administration in patients undergoing elective intracranial surgery: A randomised, prospective study.

    Science.gov (United States)

    Sethi, Rakesh; Naqash, Imtiaz A; Bajwa, Sukhminder Jit Singh; Dutta, Vikas; Ramzan, Altaf Umar; Zahoor, Syed Amir

    2016-01-01

    The glucocorticoid dexamethasone in a bolus dose of 8-10 mg followed by quarterly dose of 4 mg is commonly used during intracranial surgery so as to reduce oedema and vascular permeability. However, the detrimental hyperglycaemic effects of dexamethasone may override its potentially beneficial effects. The present prospective, randomised study aimed at comparing the degree and magnitude of hyperglycaemia induced by prophylactic administration of dexamethasone in patients undergoing elective craniotomy. Sixty American Society of Anaesthesiologist (ASA) grade-I and II patients were randomly assigned to three groups of 20 patients each. Group-I received dexamethasone during surgery for the first time. Group-II received dexamethasone in addition to receiving it pre-operatively, whereas Group-III (control group) patients were administered normal saline as placebo. Baseline blood glucose (BG) was measured in all the three groups before induction of anaesthesia and thereafter after every hour for 4 h and then two-hourly. Besides intra- and intergroup comparison of BG, peak BG concentration was also recorded for each patient. Statistical analysis was carried out with analysis of variance (ANOVA) and Student's t-test and value of P < 0.05 was considered statistically significant. Baseline BG reading were higher and statistically significant in Group-II as compared with Group-I and Group-III (P < 0.05). However, peak BG levels were significantly higher in Group-I than in Group-II and III (P < 0.05). Similarly, the magnitude of change in peak BG was significantly higher in Group-I as compared to Group-II and III (P < 0.05). Peri-operative administration of dexamethasone during neurosurgical procedures can cause significant increase in BG concentration especially in patients who receive dexamethasone intra-operatively only.

  4. Evaluating the intra- and interobserver reliability of three-dimensional ultrasound and power Doppler angiography (3D-PDA) for assessment of placental volume and vascularity in the second trimester of pregnancy.

    Science.gov (United States)

    Jones, Nia W; Raine-Fenning, Nick J; Mousa, Hatem A; Bradley, Eileen; Bugg, George J

    2011-03-01

    Three-dimensional (3-D) power Doppler angiography (3-D-PDA) allows visualisation of Doppler signals within the placenta and their quantification is possible by the generation of vascular indices by the 4-D View software programme. This study aimed to investigate intra- and interobserver reproducibility of 3-D-PDA analysis of stored datasets at varying gestations with the ultimate goal being to develop a tool for predicting placental dysfunction. Women with an uncomplicated, viable singleton pregnancy were scanned at 12, 16 or 20 weeks gestational age groups. 3-D-PDA datasets acquired of the whole placenta were analysed using the VOCAL software processing tool. Each volume was analysed by three observers twice in the A plane. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICCs) and Bland Altman plots. At each gestational age group, 20 low risk women were scanned resulting in 60 datasets in total. The ICC demonstrated a high level of measurement reliability at each gestation with intraobserver values >0.90 and interobserver values of >0.6 for the vascular indices. Bland Altman plots also showed high levels of agreement. Systematic bias was seen at 20 weeks in the vascular indices obtained by different observers. This study demonstrates that 3-D-PDA data can be measured reliably by different observers from stored datasets up to 18 weeks gestation. Measurements become less reliable as gestation advances with bias between observers evident at 20 weeks. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  7. Comparison of interscalene brachial plexus block and intra-articular local anesthetic administration on postoperative pain management in arthroscopic shoulder surgery

    Directory of Open Access Journals (Sweden)

    Recep Aksu

    2015-06-01

    Full Text Available BACKGROUND AND OBJECTIVES: In this study, the aim was to compare postoperative analgesia effects of the administration of ultrasound-guided interscalene brachial plexus block and intra-articular bupivacaine carried out with bupivacaine. METHODS: In the first group of patients 20 mL 0.25% bupivacaine and ultrasound-guided interscalene brachial plexus block (ISPB were applied, while 20 mL 0.25% bupivacaine was given via intra-articular (IA administration to the second group patients after surgery. Patients in the third group were considered the control group and no block was performed. Patient-controlled analgesia (PCA with morphine was used in all three groups for postoperative analgesia. RESULTS: In the ISPB group, morphine consumption in the periods between 0-4, 6-12 and 12-24 postoperative hours and total consumption within 24 h was lower than in the other two groups. Morphine consumption in the IA group was lower than in the control group in the period from 0 to 6 h and the same was true for total morphine consumption in 24 h. Postoperative VASr scores in the ISPB group were lower than both of the other groups in the first 2 h and lower than the control group in the 4th and 6th hours (p < 0.05. In the IA group, VASr and VASm scores in the 2nd, 4th and 6th hours were lower than in the control group (p < 0.05. CONCLUSION: Interscalene brachial plexus block was found to be more effective than intra-articular local anesthetic injection for postoperative analgesia.

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  9. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  11. Narrow intra-individual variation of maternal thyroid function in pregnancy based on a longitudinal study on 132 women

    DEFF Research Database (Denmark)

    Boas, M.; Forman, Julie Lyng; Juul, A.

    2009-01-01

    BACKGROUND: Adaptive alterations in maternal physiology cause changes in thyroid hormone levels throughout pregnancy, and precise biochemical evaluation is thus highly dependent on gestation-specific reference intervals and expected intra-individual variation. OBJECTIVE: The aim of the study...... was the assessment of the intra-individual variation as well as the longitudinal course of thyroid hormones during normal pregnancy and factors that influence the normal reference range for thyroid function. For this purpose, a longitudinal statistical model was applied. DESIGN: In a cohort of 132 pregnant women......, serial blood samples were obtained and ultrasound scans were performed throughout pregnancy. METHODS: Serum levels of TSH, free and total thyroxine (T(4)), free and total triiodothyronine (T(3)) as well as autoantibodies against thyroid peroxidase and thyroglobulin were measured in 979 serum samples...

  12. Acoustic bubble sorting for ultrasound contrast agent enrichment.

    Science.gov (United States)

    Segers, Tim; Versluis, Michel

    2014-05-21

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.

  13. A randomised controlled study of the post-operative analgesic efficacy of ultrasound-guided pectoral nerve block in the first 24 h after modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2018-01-01

    Full Text Available Background and Aims: Breast cancer has become the most common cancer in women worldwide. Acute post-operative pain following mastectomy remains a challenge for the anaesthesiologist despite a range of treatment options available. The present study aimed to compare the post-operative analgesic efficacy of pectoral nerve (Pecs block performed under ultrasound with our standard practice of opioids and non-steroidal anti-inflammatory drugs for mastectomy. Methods: This randomised controlled study was conducted at a tertiary care teaching hospital in India, after obtaining ethical clearance. Fifty adult female patients posted for elective unilateral modified radical mastectomy were divided into two groups as follows: Group I (general anaesthesia only and Group II (general anaesthesia plus ultrasound-guided Pecs block, each comprising 25 patients. Post-randomisation, patients in Group I received general anaesthesia, while Group II patients received ultrasound-guided Pecs block followed by general anaesthesia after 20 min. The primary outcome was measured as patient-reported pain intensity using Visual Analogue Scale (VAS at rest. Statistical analysis was performed using Student's t-test and Mann–Whitney U-test. Data were entered into MS Excel spreadsheet and analysis was performed using the Statistical Package for the Social Sciences version 23.0. Results: VAS score was significantly lower in Group II at rest and on abduction post-operatively at all time intervals (P < 0.001. The 24-h tramadol consumption was significantly less in Group II compared to Group I (114.4 ± 4.63 mg vs. 402.88 ± 74.22, P < 0.0001. Conclusion: Pecs block provided excellent post-operative analgesia in the first 24 h.

  14. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  15. Intra-operative adjustment of standard planes in C-arm CT image data.

    Science.gov (United States)

    Brehler, Michael; Görres, Joseph; Franke, Jochen; Barth, Karl; Vetter, Sven Y; Grützner, Paul A; Meinzer, Hans-Peter; Wolf, Ivo; Nabers, Diana

    2016-03-01

    With the help of an intra-operative mobile C-arm CT, medical interventions can be verified and corrected, avoiding the need for a post-operative CT and a second intervention. An exact adjustment of standard plane positions is necessary for the best possible assessment of the anatomical regions of interest but the mobility of the C-arm causes the need for a time-consuming manual adjustment. In this article, we present an automatic plane adjustment at the example of calcaneal fractures. We developed two feature detection methods (2D and pseudo-3D) based on SURF key points and also transferred the SURF approach to 3D. Combined with an atlas-based registration, our algorithm adjusts the standard planes of the calcaneal C-arm images automatically. The robustness of the algorithms is evaluated using a clinical data set. Additionally, we tested the algorithm's performance for two registration approaches, two resolutions of C-arm images and two methods for metal artifact reduction. For the feature extraction, the novel 3D-SURF approach performs best. As expected, a higher resolution ([Formula: see text] voxel) leads also to more robust feature points and is therefore slightly better than the [Formula: see text] voxel images (standard setting of device). Our comparison of two different artifact reduction methods and the complete removal of metal in the images shows that our approach is highly robust against artifacts and the number and position of metal implants. By introducing our fast algorithmic processing pipeline, we developed the first steps for a fully automatic assistance system for the assessment of C-arm CT images.

  16. Real-Time Implementation of Medical Ultrasound Strain Imaging System

    International Nuclear Information System (INIS)

    Jeong, Mok Kun; Kwon, Sung Jae; Bae, Moo Ho

    2008-01-01

    Strain imaging in a medical ultrasound imaging system can differentiate the cancer or tumor in a lesion that is stiffer than the surrounding tissue. In this paper, a strain imaging technique using quasistatic compression is implemented that estimates the displacement between pre- and postcompression ultrasound echoes and obtains strain by differentiating it in the spatial direction. Displacements are computed from the phase difference of complex baseband signals obtained using their autocorrelation, and errors associated with converting the phase difference into time or distance are compensated for by taking into the center frequency variation. Also, to reduce the effect of operator's hand motion, the displacements of all scanlines are normalized with the result that satisfactory strain image quality has been obtained. These techniques have been incorporated into implementing a medical ultrasound strain imaging system that operates in real time.

  17. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  18. Towards clinical prostate ultrasound elastography using full inversion approach.

    Science.gov (United States)

    Mousavi, Seyed Reza; Sadeghi-Naini, Ali; Czarnota, Gregory J; Samani, Abbas

    2014-03-01

    Various types of cancers including prostate cancer are known to be associated with biological changes that lead to tissue stiffening. Digital rectal examination is based on manually palpating the prostate tissue via the rectum. This test lacks sufficient accuracy required for early diagnosis which is necessary for effective management of prostate cancer. To develop an effective prostate cancer diagnostic technique, the authors propose an imaging technique that maps the distribution of the relative prostate tissue's elasticity modulus. Unlike digital rectal examination, this technique is quantitative, capable of accurately detecting small prostate lesions that cannot be sensed by manual palpation, and its accuracy is independent of the physician's experience. The proposed technique is a quasistatic elastography technique which uses ultrasound imaging to acquire tissue displacements resulting from transrectal ultrasound mechanical stimulation. The system involves a standard ultrasound imaging unit with accessibility to its radiofrequency data. The displacements are used as data for the tissue elasticity reconstruction. This reconstruction does not require tissue segmentation and is based on physics governing tissue mechanics. It is formulated using an inverse problem framework where elastic tissue deformation equations are fully inverted using an iterative scheme where each iteration involves stress calculation followed by elastic modulus updating until convergence is achieved.In silico and tissue mimicking phantom studies were conducted to validate the proposed technique, followed by a clinical pilot study involving two prostate cancer patients with whole-mount histopathology analysis on prostatectomy specimens to confirm a cancer location. The phantom studies demonstrated robustness and reasonably high accuracy of the proposed method. Obtained Young's modulus ratios indicated reconstruction errors of less than 12%. Reconstructed elastic modulus images of the two

  19. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  20. Assessment of substantia nigra echogenicity in German and Filipino populations using a portable ultrasound system.

    Science.gov (United States)

    Go, Criscely L; Frenzel, Antonia; Rosales, Raymond L; Lee, Lillian V; Benecke, Reiner; Dressler, Dirk; Walter, Uwe

    2012-02-01

    Transcranial sonography of the substantia nigra for diagnosing premotor stages of Parkinson disease has been attracting increasing interest. Standard reference values defining an abnormal increased echogenic size (hyperechogenicity) of the substantia nigra have been established in several populations using high-end stationary ultrasound systems. It is unknown whether a portable ultrasound system can be appropriately used and how the Filipino population would compare with the well-studied white population. We prospectively studied substantia nigra echogenic sizes and third ventricle widths in 71 healthy adult German participants and 30 age- and sex-matched Filipino participants using both a well-established stationary ultrasound system (in the German cohort) and a recently distributed portable ultrasound system (in both ethnic cohorts). Mean substantia nigra echogenic sizes, cutoff values defining abnormal hyperechogenicity, and intra-rater reliability were similar with both systems and in both ethnic cohorts studied. The Filipino and German participants did not differ with respect to the frequency of insufficient insonation conditions (each 3%) and substantia nigra hyperechogenicity (10% versus 9%; P = .80). However, third ventricle widths were smaller in the Filipino than the German participants (mean ± SD, 1.6 ± 1.1 versus 2.4 ± 1.0 mm; P = .004). The frequency of substantia nigra hyperechogenicity appears to be homogeneous in white and Asian populations. Screening for this feature may well be performed with a present-day portable ultrasound system.